Sumitube KH200-TW

Page 1

Technical datasheet Page 1 of 2

®

Sumitube KH230(TW)

Fluoropolymer, 2:1

Operating Temperature: -55 up to 230°C

Surface: Glossy Marking: None

SAE- AMS- DTL-23053/18 class 3

Dimensions

BEFORE SHRINKAGE

AFTER SHRINKAGE

Inner diameter (EID) min.

Wall thickness (RWT) min- max

Unit quantity

[mm]

[mm]

[m]

[m]

1,20

0,23 - 0,31

60

300

2,40

0,23 - 0,31

60

300

6,40

3,20

0,28 - 0,38

60

300

3/8

9,50

4,80

0,28 - 0,38

30

180

1/2

12,7

6,40

0,28 - 0,38

30

150

3/4

19,1

9,50

0,36 - 0,50

15

150

1

25,4

12,7

0,41 - 0,55

30

150

[type]

[mm]

1/8

3,20

3/16

4,80

1/4

Inner diameter (RID) max.

DELIVERY UNITS

Colours & Technical drawing

STANDARD COLOURS

black

SPECIAL COLOURS

upon request

TECHNICAL DRAWING

Box quantity


Technical datasheet Page 2 of 2 ®

Sumitube KH230(TW)

Fluoropolymer, 2:1

Technical properties PHYSICAL PROPERTIES PROPERTY

TEST METHOD

REQUIREMENT

TYPICAL VALUE

Longitudinal Change

SAE- AMS- DTL-23053

0 ± 10%

-5%

Tensile Strength

SAE- AMS- DTL-23053

Min. 10,4 MPa

≥ 14 MPa

Elongation at Break

SAE- AMS- DTL-23053

Min. 250%

≥ 400%

TEST METHOD

REQUIREMENT

TYPICAL VALUE

Operating Temperature

SAE- AMS- DTL-23053

-55 up to 200°C

-55 up to 230°C

Min. Shrink Temperature

Arrhenius- Plot

full recovery

130°C

Shrinking starts at

Arrhenius- Plot

THERMAL PROPERTIES PROPERTY

70°C

Heat Shock (300°C x 4h)

SAE- AMS- DTL-23053

no cracking

Pass

Elongation after heat ageing (250°C x 168h)

SAE- AMS- DTL-23053

Min. 200%

≥ 300%

Low temperature flexibility (-55°C x 4h)

SAE- AMS- DTL-23053

no cracking

Pass

Copper Corrosion (175°C x 16h)

SAE- AMS- DTL-23053

no corrosion

Pass

Clarity Stability (200°C x 24h)

SAE- AMS- DTL-23053

no change

Pass

CHEMICAL PROPERTIES PROPERTY

TEST METHOD

REQUIREMENT

TYPICAL VALUE

Flammability

UL 224

VW-1

Pass

Water Absorption (23°C x 24h)

SAE- AMS- DTL-23053

Max. 0,1%

Pass

Fluid Resistance (after immersion 24°C x 24h)

SAE- AMS- DTL-23053

Min. 8,2 MPa (Tensile Strength)

≥ 12 MPa

Fluid Resistance (after immersion 24°C x 24h)

SAE- AMS- DTL-23053

Min. 250% (Elongation)

Pass

NASA SP- R-0022 A

TML 1,0% / Max. CVCM 0,1%

Pass

TYPICAL VALUE

Vacuum outgassing

ELECTRICAL PROPERTIES PROPERTY

TEST METHOD

REQUIREMENT

Volume Resistivity

SAE- AMS- DTL-23053

Min. 10 Ω·cm

≥ 10 Ω·cm

Dielectric Strength

SAE- AMS- DTL-23053

Min. 19,7 kV/ mm

≥ 30 kV/ mm

13

Cambridge Technologies: ABN 91 005 288 200 No. 17, 85-91 Keilor Park Drive, Aerolink Business Park, Tullamarine Victoria Australia 3043 Tel: +61 3 8336 1000 Fax: +61 3 8336 1166 Web Site: www.cambridge-technologies.com

14