Ae 2 01 floor & ceiling plans

Page 1

ARCHITECTURE

FLOOR PLAN GENERAL NOTES

A

B

C

3/ Ae-5.01 2

D

E

F 8" PREFINISHED METAL GUTTER

Ae-5.02

25'-0"

25'-0"

25'-0"

25'-0"

1'-5 1/8" 6 7/8"

PREFINISHED METAL DOWNSPOUT W/ DOWNSPOUT BOOT- REFER TO CIVIL DRAWINGS FOR SUB SURFACE CONTINUATION

1'-4"

1'-0"

25'-0"

1. DIMENSIONS NOTED "VERIFY" SHALL BE CONFIRMED IN THE FIELD. REPORT VARIATIONS TO THE ARCHITECT FOR RESOLUTION BEFORE PROCEEDING WITH WORK AFFECTED. 2. DIMENSIONS NOTED "CLEAR" ARE MEASURED FROM THE FACE OF FINISH MATERIAL TO THE FACE OF FINISH MATERIAL. 3. ALIGN DIFFERENT WALL TYPES SO THAT CONTINUOUS FACES OF WALLS ARE FLUSH. 4. ELECT. PANELS, FIRE EXTINGUISHERS AND OTHER ITEMS IN WALLS SHALL BE BACKED WITH DRYWALL TO MAINTAIN REQUIRED RATINGS. 5. REFER TO ACCESSIBILITY INFORMATION SHEETS FOR INFORMATION RELATED TO ACCESSIBILITY, INCLUDING CLEARANCES, MOUNTING HEIGHTS AND OTHER REQUIREMENTS. REFER TO APPLICABLE ACCESSIBILITY STANDARDS FOR ADDITIONAL ACCESSIBILITY INFORMATION NOT SHOWN ON THE ACCESSIBILITY INFORMATION SHEETS. 6. ROOM NAMES AND NUMBERS SHOWN ARE FOR PURPOSES OF COORDINATION DURING CONSTRUCTION AND DO NOT NECESSARILY REPRESENT FINAL ROOM NAMES OR NUMBERS. 7. FINISH FLOOR ELEVATIONS OR DIMENSIONS ARE TO THE TOP OF CONCRETE SLAB UNLESS OTHERWISE NOTED. 8. REFER TO FINISH PLANS FOR FINISH FLOORING PATTERNS AND EXTENT OF SPECIAL WALL FINISHES. 9. ALL CONCEALED BLOCKING IS TO BE FIRE TREATED. VERIFY BLOCKING REQUIREMENTS FOR OWNER PROVIDED EQUIPMENT WITH OWNER. 10. GENERAL CONTRACTOR IS TO COORDINATE AND INSTALL ALL OWNER-PROVIDED ITEMS. 11. PROVIDE TRANSITION STRIPS AT DISSIMILAR FLOORING MATERIAL JOINTS. 12. ALL FURNITURE, FIXTURES AND EQUIPMENT SHOWN ARE FOR COORDINATION PURPOSES ONLY. 13. KEYNOTES AND LEGENDS ARE TYPICAL FOR ALL FLOOR PLAN SHEETS, AND MAY NOT APPLY TO EACH SHEET. 14. REFER TO CIVIL DRAWINGS FOR SITE WORK. 15. REFERENCE STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED INCLUDING NECESSARY FRAMING, BLOCKING, ETC. 16. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.. 17. COORDINATE CLEAR OPENINGS AND DIMENSIONS AS REQUIRED AT EQUIPMENT TO ACCOMODATE INDIVIDUAL MANUFACTURER'S REQUIREMENTS. NOTIFY ARCHITECT AND SUBMIT PROPOSED REVISIONS PRIOR TO ANY MODIFICATIONS. 18. REFERENCE ROOF PLAN FOR LOCATIONS OF ROOF HATCHES AND EXTERIOR LADDERS. 19. REFER TO CIVIL SITE PLAN FOR EXACT LOCATION AND ORIENTATION OF BUILDING ON CAMPUS. 20 INSTALL MASONRY CONTROL JOINTS AT ALL INSIDE MASONRY CORNERS. REFER TO BUILDING ELEVATIONS FOR ADDITIONAL LOCATIONS.

CMU WALL

8"

1

25'-0"

PRE-ENGINEERED STEEL FRAME, PAINT EXPOSED STRUCTURE RE: STRUCTURAL

1

1

Ae-5.02

Ae-5.02

2

REFLECTED CEILING PLAN GENERAL NOTES 1. REFER TO MEP DRAWINGS AND SPECIFICATIONS FOR DESIGN OF THEIR RESPECTIVE SYSTEMS (DUCT SIZES, CIRCUITING, ETC.). LOCATIONS OF FIXTURES SHALL BE AS SHOWN ON ARCHITECTURAL PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY CONFLICTS PRIOR TO CONSTRUCTION. 2. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, DUCTS, STRUCTURAL ELEMENTS, AND OTHER APPLICABLE ITEMS. ARRANGE AND MODIFY NONVISIBLE ITEMS TO ENSURE ADEQUATE CLEARANCE FOR CEILING LAYOUT AS SHOWN. 3. REFER TO ELECTRICAL DRAWINGS FOR FIXTURE TYPE AND SCHEDULE. 4. REFER TO INTERIOR ELEVATIONS AND ROOM FINISH SCHEDULE FOR ADDITIONAL INFORMATION CONCERNING CEILIGN HEIGHTS, CEILING MATERIALS AND FURRED CEILINGS. 5. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR DIFFUSERS, FIXTURES, EQUIPMENT, GRILLES, DUCTS, ETC. - TYPES AND SIZES. 6. CEILINGS AND OTHER SUSPENDED ITEMS SHALL BE ATTACHED TO STRUCTURE BY FULLY EMBEDDED OR "SHEAR" CONNECTION. PULL OUT CONNECTIONS ARE NOT ACCEPTABLE. 7. REVEAL MOLDING TO BE USED AT ALL INTERSECTIONS OF DIFFERENT MATERIALS. ALL SOFFIT REVEALS SHALL BE A CONTINUATION OF VERTICAL WALL REVEALS.

ASSOCIATE ARCHITECT FUSE ARCHITECTURE STUDIO 702 SAN ANTONIO ST. AUSTIN, TX 78701 512-992-1520

HALFF ASSOCIATES 4030 W BREAKER LN. SUITE 450 AUSTIN, TX 78759 512-777-4600

STRUCTURAL JASTER-QUINTANILLA & ASSOC. 1608 W. 6TH SUITE 100 AUSTIN, TX 78703 512-474-9094

MEP HENDRIX CONSULTING ENGINEERS 115 E. MAIN ST. ROUND ROCK, TX 78664 512-218-0060

LANDSCAPE COLEMAN & ASSOCIATES 9890 SILVER MOUNTAIN DR. AUSTIN, TX 78737 512-476-2090

FUELING SSG 17041 EL CAMINO REAL SUITE 200 HOUSTON, TX 77058 281-486-1943

PREFORMED, PREFINISHED METAL PANEL ROOF SYSTEM AS SPECIFIED

25'-0"

07/14/2016

CIVIL

4/ Ae-5.01

2/ Ae-5.01

EMS VEHICLE STORAGE e101

BLGY ARCHITECTURE 2204 FORBES DRIVE SUITE 101 AUSTIN, TX 78754 (512) 977-0390

F F & E TECHCENTER DESIGN P.O. BOX 91705 AUSTIN, TX 78709 512-407-8447

ACOUSTICS

8"

BAi 4006 SPEEDWAY AUSTIN, TX 78751 512-476-3464

1'-4"

3

TECHNOLOGY & SECURITY TRUE NORTH CONSULTING GROUP P.O. BOX 2169 HEWITT, TX 76643 254-229-0099

1/ Ae-5.01

ROOFING/WATERPROOFING ARMKO 4705 PINEHURST DR. S AUSTIN, TX 78747 512-415-3411

1/8" = 1'-0"

2 Ae-5.02

A

B

C

3/ Ae-5.01

D

E

6" DIAM. X 4'-0" HIGH CAST IN PLACE METAL BOLLARD, PAINTED, TYP.

F

129'-0" 2'-0"

25'-0"

25'-0"

25'-0"

25'-0"

25'-0"

8" PREFINISHED METAL DOWNSPOUT W/ CONCRETE SPLASH BLOCK

2'-0"

2'-0"

1 Ae-10.01 8"

1

F.E.

PRE-ENGINEERED STEEL FRAME RE: STRUCTURAL

F.E.

25'-0"

CMU WALL

1

1

Ae-5.02

Ae-5.02

EMS VEHICLE STORAGE e101

CONC. SLAB

BOLT DOWN METAL BOLLARDS - RE: 2/Ae-10.01

25'-0"

25'-0"

2/ Ae-5.01

2

4/ Ae-5.01

54'-0"

25'-0"

6" DIAM. X 4'-0" HIGH BOLT DOWN METAL BOLLARD, PAINTED, TYP. RE: 2/Ae-10.01

PROJECT NO.: ISSUE DATE

07/14/2016

8" 1'-4"

2'-0"

3

15-2800

ELECTRICAL TRANSFORMERREFER TO ELECTRICAL

F.E.

F.E.

WILLIAMSON COUNTY 3151 SE INNER LOOP

REFLECTED CEILING PLAN

NORTH CAMPUS FACILITY

2

PLAN TRUE NORTH NORTH

2 Ae-5.02 1/ Ae-5.01 E M S T R A IN IN G STO RA G E FLO O R A N D C E IL IN G P L A N S

1

FLOOR PLAN 1/8" = 1'-0"

PLAN TRUE NORTH NORTH

KEY PLAN

A e - 2 .0 1