GUIDE SYSTEM TEMPLATE-GUIDED IMPLANTATION Accurate guiding of instruments and implants Easy and convenient to use Single-use products – direct application of surgical instruments Compatible with several planning systems


Guide System System

GUIDE SYSTEM – SAFE IMPLANTATION AND IMMEDIATE TEMPORARY RESTORATION GUIDE SYSTEM – OPTIMALLY MATCHED COMPONENTS The components of the Guide System serve the template-guided preparation of the implant bed and insertion of CAMLOG® and CONELOG® SCREW-LINE implants, Promote® plus, in a partially or fully edentulous maxilla and mandible.

Driver with hexagon for manual implant insertion

Guide System CAMLOG® and CONELOG® SCREW-LINE implants, Promote® plus, including pre-mounted insertion posts with guiding shaft and depth stop for precise insertion to planned placement depth

THE GUIDE SYSTEM COMPRISES: • Laboratory instruments for fabricating a drill template and a pre-operative interim prosthesis on a master model • Surgical instruments for template-guided bone or tooth-supported implant bed preparation and implant insertion • Guide System CAMLOG ® SCREW-LINE implants, Promote® plus, with the following dimensions [ mm ]: Length

Ø 3.3

Ø 3.8

Ø 4.3

9

 

11

13

16

• G uide System CONELOG® SCREW-LINE implants, Promote® plus, with the following dimensions [ mm ]: Length

Ø 3.3

Ø 3.8

Ø 4.3

7

9

11

13

16

MORE INFORMATION AND THE GUIDE SYSTEM VIDEO AT:

www.camlog.com/products/digital-technique

Driver with ISO shaft for mechanical implant insertion

Setting tool for exact integration of the guide sleeve into the drill template

Template drill to prepare guide sleeve drill holes

Checkup pin for checking correct alignment of the guide sleeves in the template

Insertion post, color-coded Guide sleeve, color-coded

All advantages at a glance • Straightforward well-arranged system due to small number of required parts • High precision level due to well matched products – “all from a single source” • Color-coded single-use drills, gingiva punches, insertion posts and guide sleeves • Convenient to use, as additional sleeves and depth stops are not required • Choice between several planning systems • Consistent implementation of all advantages of software-based 3D implant planning

• A ccurate preparation of temporary restoration and its immediate integration • No investment in additional instrument trays necessary • Optimal edge holding and hygiene of the cutting instruments due to sterility and single use • When opting for laboratory fabrication of the drill template, value creation remains with the dental laboratory


Guide System

Pre and form drills for reliable guidance – even at greater drilling depths – through stepwise preparation of the implant bed to the planned placement depth

Guided gingiva punch for transgingival minimal invasive preparation of the soft tissue

Pilot drills for optional use in lateral bone condensation or to ensure correct alignment of the drilling axis under difficult anatomical circumstances

Form Drill Cortical Bone, for optional use in bone classes 1 and 2*

PRECISION WITH 3D PLANNING – SAFETY FOR PATIENTS AND USERS 3D planning with an implant planning software and implementation with the Guide System offers the user simple, predictable and safe implant bed preparation. While planning the precise implant positioning, all physiological structures can be considered. DRILL TEMPLATE WITH DEPTH STOP The Guide System Guiding sleeves can be integrated in the drilling templates which are fabricated via conventional techniques in the laboratory or with the aid of computer-guided methods such as CNC milling, stereo lithography or 3D printing. In the case of computer-guided methods, the laboratory instruments are not required for the fabrication and checking of the template. After completion, the drill template serves to: • position lab analogs during preoperative fabrication of the model and the temporary restoration • guiding surgical instruments of the Guide System during implant bed preparation • g uiding the Guide System SCREW-LINE implants during insertion. TEMPORARY RESTORATION OPTION IMMEDIATELY FOLLOWING IMPLANTATION Due to the precise 3D planning option of the implant positions, the temporary restoration can already be fabricated prior to actual surgery with the aid of the drilling template and the Guide System insertion posts for laboratory analogs. This means that the patient can be restored temporarily immediately after surgery.

All surgical drills are fitted with circumferential color coding on the shaft and laser markings with length and diameter to ensure fast and clear assignment.

* Lekholm & Zarb, 1985


Guide System

The overall benefit of Guided Surgery only comes into its own if implementation is performed precisely and consistently. This means continuing with guided operation after pilot drilling and also inserting the implant with the template. This is the only way to be assured that all planning criteria have been implemented. The necessary drill sets have already been offered by a number of implant manufacturers. The easiest, most precise and clearly arranged drill set is the CAMLOG Guide System. It is convenient to use, as additional sleeves and depth stops are not required. All work steps, from punching the gingiva to inserting the implant, can be performed by just using a single sleeve. My clinicians love the CAMLOG Guide System.

Implantology without 3-dimensional implant planning is unthinkable today. Today, high precision and accurate planning programs enable the fabrication of precise surgery templates. This makes it even more important to find simple tools with which planning can be implemented for surgery. For this reason I use the Guide System by CAMLOG, as it greatly simplifies surgical intervention with just a single sleeve. The perfect match of template, sleeve and drill set allows me to concentrate fully on the individual patient case. In addition, the CAMLOG Guide System does not tie me to a specific planning system. This freedom is important to me as practice owner. Dr. Claudio Cacaci | Munich

MDT Gerhard Stachulla | Bergen

In my opinion the CAMLOG Guide System embodies a convenient and predictable method and conveys a perfect feeling from a clinical standpoint. The reduced number of drills and the option of working without additional depth stop, simplifies and accelerates the clinical protocol compared to most other systems available on the market. Colorcoding makes the guide sleeves easy to assign to the corresponding implant diameter and is extremely precise. The simplified drilling sequence and the excellent cutting performance of the drills allow a rapid preparation of the implant bed. The corresponding Guide insertion posts ensure safe and accurate positioning of the implant.

A correct diagnosis and good planning are the basis for successful work. High precision, absolute control and minimal trauma are essential for performing implant surgery today. For this reason, one of the biggest advances in my surgery has been the CAMLOG Guide System in combination with the option of implementing immediate loading easier and simpler. Additional, clear results are an improved communication with patients as well as the peace of mind and the security for both sides. Dr. Juan Zufia | Madrid