flow control valves serie TMCU-TMVU-TMCO

Page 1

TMCU TMVU TMCO

S E R I E S

Catalogue 2005 - 2006

5 Flow control valves Series TMCU – TMVU – TMCO

The unidirectional and bidirectional flow controllers, series TMCU, TMVU, TMCO have been revised in order to decrease their dimensions and improve their flow rate characteristics. Their construction allows for easy assembly to cylinders and valves and allows the regulation adjustment to be blocked, once it has been set.

A U T O M A T I C

V A L V E S

Unidirectional and bidirectional G1/8, G1/4, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2 - 3,8 - 5,8 - 8 mm

GENERAL DATA

Construction Valve group Materials Mounting Ports Installation Operating temperature

needle-type unidirectional and bi-directional controller OT58 - technopolymer - NBR by male thread G1/8 - G1/4 - G3/8 - G1/2 in any position 0 ÷ 60°C (with dry air - 20°C)

*If lubricated air is used, it is recommended to use ISOVG32 oil. Once applied the lubrication should never be interrupted.

PNEUMATIC DATA

Operating pressure Nominal pressure Nominal flow Nominal dia. Fluid

5.05 001

0,5 ÷ 10 bar 6 bar see graph Tube 4 Ø2 - Tube 6 Ø3.8 - Tube 8 Ø5.8 - Tube 10 Ø8 filtered air

The company reserves the right to vary models and dimensions without notice. These products are designed for industrial applications and are not suitable for sale to the general public.


S E R I E S

Catalogue 2005 - 2006

TMCU TMVU TMCO

5 CODING OF FLOW CONTROL VALVES

TM CU 9 74 - 1/8 - 6

ASSEMBLY CU = on cylinders unidirectional VU = on valves unidirectional CO = bi-directional VERSIONS 9 = needle (manually operated)

FLOW CONTROL RANGE Size Ø tube 72 = 2 4 74 = 3.8 6 76 = 5.8 8 78 = 8 10

PORTS 1/8 1/4 3/8 1/2

Ø TUBE 4 6 8 10

UNIDIRECTIONAL AND BIDIRECTIONAL FLOW CONTROLLERS

To ensure the right choice of unidirectional flow controller, proceed as follows: calculate the quantity of air in Nl/min (see cylinder Table); determine the stroke time of the cylinder; refer to graph to see which controller is the right type. In the case of bi-directional regulators, refer to the graph and check whether the flow control range is suitable for the work required.

TUBE Ø6

Flow Qn (Nl/min.) from 2 → 1 with controller OPEN: 400 Flow Qn (Nl/min.) from 2 → 1 with controller CLOSED: 280 NB: Qn is determined with a supply pressure of 6 bar and with ∆P= 1 bar at the outlet N° = of screw turns

Flow Qn (Nl/min.) from 2 → 1 with controller OPEN: 550 Flow Qn (Nl/min.) from 2 → 1 with controller CLOSED: 280 NB: Qn is determined with a supply pressure of 6 bar and with ∆P= bar at the outlet N° = of screw turns

Qn (Nl/min)

The company reserves the right to vary models and dimensions without notice. These products are designed for industrial applications and are not suitable for sale to the general public.

V A L V E S

TUBE Ø4

A U T O M A T I C

ACTUATION TM = manual

Qn (Nl/min)

5.05 001


S E R I E S

TMCU TMVU TMCO

Catalogue 2005 - 2006

5

A U T O M A T I C

V A L V E S

UNIDIRECTIONAL AND BIDIRECTIONAL FLOW CONTROLLERS TUBE Ø8

TUBEO Ø10

Flow Qn (Nl/min.) from 2 → 1 with controller OPEN: 890 Flow Qn (Nl/min.) from 2 → 1 with controller CLOSED: 460 NB: Qn is determined with a supply pressure of 6 bar and with ∆P= bar at the outlet N° = of screw turns

Flow Qn (Nl/min.) from 2 → 1 with controller OPEN: Ø 10-1200/Ø12-1250 Flow Qn (Nl/min.) from 2 → 1 with controller CLOSED: Ø 10-600/Ø12-600 NB: Qn is determined with a supply pressure of 6 bar and with ∆P= bar at the outlet N° = of screw turns Qn (Nl/min)

Qn (Nl/min)

Tube Ø 10 Tube Ø 12

Valves Series TMCU Unidirectional flow controller for mounting on single-acting and double-acting cylinders. Knurled screw or male setscrew wrench adjustment. Ports G1/8, G1/4, G3/8, G1/2

DIMENSIONS Mod. TMCU TMCU TMCU TMCU TMCU TMCU TMCU

5.05 003

972-1/8-4 974-1/8-6 974-1/4-6 976-1/4-8 976-3/8-8 978-3/8-10 978-1/2-10

A B F G1/8 4 11 G1/8 6 11 G1/4 6 11 G1/4 8 13.5 G3/8 8 13.5 G3/8 10 19 G1/2 10 19

H 5 5 6 6 7 7 8

L 40 40 41 46.5 47.5 51 52

M S 22 15.5 22 15.5 22 15.5 25 18 25 18 32 20 32 20

SW 15 15 19 19 19 23 24

SWI 1.5 1.5 1.5 2.5 2.5 2.5 2.5

Z 46 46 47 53.5 54.5 58.5 59.5

The company reserves the right to vary models and dimensions without notice. These products are designed for industrial applications and are not suitable for sale to the general public.


S E R I E S

Catalogue 2005 - 2006

TMCU TMVU TMCO

5 Valves Series TMVU

DIMENSIONS 972-1/8-4 974-1/8-6 974-1/4-6 976-1/4-8 976-3/8-8 978-3/8-10 978-1/2-10

A B F G1/8 4 11 G1/8 6 11 G1/4 6 11 G1/4 8 13.5 G3/8 8 13.5 G3/8 10 19 G1/2 10 19

H 5 5 6 6 7 7 8

L 40 40 41 46.5 47.5 51 52

M S 22 15.5 22 15.5 22 15.5 25 18 25 18 32 20 32 20

SW 15 15 19 19 19 23 24

SWI 1.5 1.5 1.5 2.5 2.5 2.5 2.5

Z 46 46 47 53.5 54.5 58.5 59.5

H 5 5 6 6 7 7 8

L 40 40 41 46.5 47.5 51 52

M S 22 15.5 22 15.5 22 15.5 25 18 25 18 32 20 32 20

SW 15 15 19 19 19 23 24

SWI 1.5 1.5 1.5 2.5 2.5 2.5 2.5

Z 46 46 47 53.5 54.5 58.5 59.5

Valves Series TMCO Bidirectional flow controller . Knurled screw or male setscrew wrench adjustment. Ports G1/8, G1/4, G3/8, G1/2

V A L V E S

Mod. TMVU TMVU TMVU TMVU TMVU TMVU TMVU

A U T O M A T I C

Unidirectional flow controller for mounting on valves. Knurled screw or male setscrew wrench adjustment. Ports G1/8, G1/4, G3/8, G1/2

DIMENSIONS Mod. TMCO TMCO TMCO TMCO TMCO TMCO TMCO

972-1/8-4 974-1/8-6 974-1/4-6 976-1/4-8 976-3/8-8 978-3/8-10 978-1/2-10

A B F G1/8 4 11 G1/8 6 11 G1/4 6 11 G1/4 8 13.5 G3/8 8 13.5 G3/8 10 19 G1/2 10 19