2 minute read

Safety Modules

Carlo Gavazzi special purpose safety relay modules provide an internationally CARLO GAVAZZI A utomation Components approved interface to specific safety related devices on a machine. Emergency Stop, Two-Hand Control, Safety Gate, and Elevator Leveling modules are suitable for applications up to Safety Category 4.

For larger and more complex safety installations, Carlo Gavazzi’s CERTUS safety system supports up to 128 inputs and 16 pairs of programmable solid state outputs in a compact modular system. CERTUS provides robust versatile safety logic, enabling more flexibility than standard safety relay modules. The optional CERTUS Bus Transfer module allows the CERTUS system to be interconnected with up to six different remote locations. The CERTUS Data and Diagnostic module supports communication of critical data on a variety of popular industrial communication networks.

CARLO GAVAZZI

A utomation Components

USA Tel: 847.465.6100 Fax: 800.222.2659 Canada Tel: 888.575.2275 Fax: 905.542.2248 Mexico Tel and Fax: 52.55.5373.7042 www.GavazziOnline.com • Info@CarloGavazzi.com For more detailed information, visit: www.GavazziOnline.com/ twitter.com/CarloGavazziNA facebook.com/CarloGavazziNASafetyModules Visit our website for downloadable data sheets, brochures and pricing: www.GavazziOnline.comTwo-Hand Control Emergency Stop

ND12D NES

CARLO GAVAZZI

A utomation Components

Special purpose safety relay module, designed for twohand control in high risk applications, such as presses and punches. Provides up to Performance Level “e”, and meets EN574 requirements up to Cat. IIIC. Special purpose safety relay module, designed for Category 4 Emergency Stop applications. 2NO safety outputs (NES02), or 3NO safety + 1NC auxiliary (NES13). Automatic/ manual version, and monitored manual reset version available. Safety Gate

NSO & NSC

Special purpose safety relay module, designed for safety gate and safety magnetic sensor applications. Meets EN60204-1, EN292-1/-2, EN418 and EN1088. Safety Category 4, Performance Level “e”. Automatic/manual and monitored manual restart version available. Elevator Leveling

NA12DLIFT

Special purpose safety relay module, designed for elevator door unlocking and elevator cabin leveling control, according to Lift Directive 95/16/CE and to safety circuits requirements of EN81-1, /-2, EN12015 and EN12016 Standards. Provides up to Safety Category 4. Expansion Module

NE14D

Zero delay safety relay expansion module provides a simple means to increase the number of safety outputs on the various safety relay modules. Meets EN602041, EN202/1 and EN202/2, EN418, EN1088 and EN954-1. Includes a NC feedback output to control the internal force guided relay integrity.

Safety Controller

CERTUS

Data & Diagnostics

CERTUS

Speed Monitor

CERTUS

The CERTUS system consists of one CMM Master Control module and up to 14 Expansion I/O modules, providing up to 128 inputs and 16 output pairs. The CBT Bus Transfer module allows connection with up to six remote locations. The CERTUS Data and Diagnostic module supports communication of critical data on a variety of popular industrial communication networks, including Profibus DP, DeviceNet, CANopen, Ethernet IP, EtherCAT, PROFINET, and USB. The CERTUS Speed Monitor module provides monitoring and control of zero speed, maximum speed, speed range and direction. Up to 4 configurable speed thresholds for up to 2 outputs, for control of 2 independent axes. The CERTUS Multifunction modules can be used with various types of inputs, including E-Stops, limit switches, non-contact switches, safety light curtains and safety mats. Various output relay configurations and time delay options available. CERTUS I/O expansion modules work seamlessly with other CERTUS modules, allowing easy expansion of I/O points. Various combinations of inputs and outputs, and relay configurations, to fit any application.

Multifunction

CERTUS

Expansion Module

CERTUS

This article is from: