Ballasts_Compact_Fluorescent

Page 1

Table of Contents Compact Fluorescent Ballasts

Ballasts

gelighting.com

T8 Instant Start

Understanding Compact Fluorescent Ballasts...........17-2 ProLine® CFL Electronic Ballasts For 13 – 70W T4 CFL Lamps................................................. 17-5

T8 Programmed Start

High-Lumen Biax® UltraMax® Instant Start Ballasts.......................................................17-8 High-Lumen Biax® UltraStart® Programmed Start Ballasts..........................................17-11

Programmed Start Dimming

CFL Magnetic Ballasts For 5 – 26W Preheat CFL Lamps......................................17-12 For 36 – 40W CFL Lamps......................................................17-13 Wiring Diagrams.............................................................17-14 Case Dimensions............................................................17-16

T5 Electronic Programmed Start T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 17-1

HID Electronic & Electromagnetic

See page E-1 for warranty information.


Understanding Compact Fluorescent Ballasts GE compact fluorescent (CFL) ballasts provide energy saving alternatives to halogen, incandescent or HID light sources. GE Multivolt ProLine® CFL programmed start ballasts combine universal voltage (108-305V) technology with multi-lamp capability, dual entry color-coded connectors and ultra system reliability to create an industry leading CFL solution for commercial and residential applications. UltraMax® and UltraStart® High Lumen Biax® ballasts with the High Lumen WattMiser® Biax® lamp provides the perfect solution for high efficiency and high lumen output in a small space. UltraMax® Instant Start Ballasts: • For use in long burn cycles (>10 hr cycles) to maintain lamp life • High efficiency (>90%) design

• Universal voltage (120-277V) • Striation control circuitry • Small compact housing

UltraStart® Programmed Start Ballasts: • For use in shorter burn cycles (<3 hr cycles) to extend lamp life • High efficiency (>90%) cathode cutout design • Universal voltage (120-277V) • Striation control circuitry

• Small compact housing • Parallel lamp operation • <700ms fast starting time •B allasts available for both F40/30W and F40/25W lamps

Multivolt ProLine® CFL ballasts are offered in three different configurations: 1) -SE description – dual entry (side or bottom) connectors, 2) -BES – bottom entry with studs for mounting to junction boxes and 3) -3W – 3-way mounting kits that allow you to have all three mounting options with one kit. Multivolt ProLine® CFL ballasts come with a five-year ballast and one-year lamp limited warranty. These ballasts also meet the EPA’s ENERGY STAR® fixture program requirements with a Consumer Class B EMI rating for residential applications, as well as a high power factor ballast design. Use the GE Multivolt ProLine® CFL Multi-Lamp compatibility chart (page 17-3) to find the right ballast for your need. ProLine® CFL Date Code System Date Code Format: 01 200801 = Week2008 = Year UltraMax® and UltraStart® Biax® ballasts have the same date code system as all linear fluorescent ballasts.

GE Compact Fluorescent Ballast nomenclature

G E C 2 1 3 - M V P S - S E GE Compact Ballast Max number of lamps and Primary Lamp type

17-2

MV = Multivolt (108 to 305 volts) UNV = Universal Voltage (Multi-Voltage) 120 or 277 = voltage

SE = Side & Bottom Entry BES = Bottom Entry with Studs 3W = 3-Way Kit (SE, BE, BES) IP = Individual Pack

PS = Programmed Start SI = Series Instant Start PH = Preheat. RS = Rapid Start RH = less than 20% THD See page E-1 for warranty information.


GE Multivolt ProLine® CFL Multi-Lamp Capability

T5

GEC242MVPS

X X X

X X

X

X

GECX40-MAX

X X X X X X X X X X X X

X X X

X X X X X X X

X

T5 Electronic Programmed Start

2D

X X X

GEC226-MVPS

Programmed Start Dimming

FT TT5

GEC218-MVPS

T8 Programmed Start

T5 Circleline

GEC213-MVPS X X X

T8 Instant Start

T4

Lamp Type 1 x 13W (CFQ/G24q, CFTR/GX24q) 2 x 13W (CFQ/G24q, CFTR/GX24q) 1 x 18W (CFQ/G24q, CFTR/GX24q) 2 x 18W (CFQ/G24q, CFTR/GX24q) 1 x 26W (CFQ/G24q, CFTR/GX24q) 2 x 26W (CFQ/G24q, CFTR/GX24q) 1 x 32W (CFQ/G24q, CFTR/GX24q) 2 x 32W (CFQ/G24q, CFTR/GX24q) 1 x 42W (CFQ/G24q, CFTR/GX24q) 2 x 42W (CFQ/G24q, CFTR/GX24q) 1 x 22W (FC9T5) 1 x 22W (FC9T5) 1 x 22W + 1 x 40W (FC9T5 + FC12T5) 1 x FC16T9 2 x 24 / 27W (FT/2G11) 1 x FT36W (2G11) 2 x FT36W (2G11) 1 x 40W (FT/2G11) & Energy Saving 28W & 25W 2 x 40W (FT/2G11) & Energy Saving 28W & 25W 3 x 40W (FT/2G11) & Energy Saving 28W & 25W 1 x 10W (CFS/GR10q) 2 x 10W (CFS/GR10q) 1 x 16W (CFS/GR10q) 2 x 16W (CFS/GR10q) 1 x 21W (CFS/GR10q) 2 x 21W (CFS/GR10q) 1 x 28W (CFS/GR10q) 2 x 28W (CFS/GR10q) 1 x 38W (CFS/GR10q) 2 x 38W (CFS/GR10q) 1 x 57W (CFTR/GX24q) 1 x 70W (CFTR/GX24q)

Ballasts

gelighting.com

X X X X X

Universal

Advance

Osram

Robertson

ESI

GE213-MVPS-3W

C213UNVSE/BE/BES

ICF-2513-H1-LD

QTP 1/2X13CF/UNV

PSM213CQMY

ES-2/1-CFQ-13/10-UNV-C/D ES-1-2D-16/10-UNV-D

GE218-MVPS-3W

C218UNVSE/BE/BES

ICF-2518-H1-LD REL-2Q18 VEL-2Q18 R-2Q18-4P-TP V-2Q18-4P-TP

QTP 1/2X18CF/UNV

PSM218CQMY

ES-2/1-CFQ-18-UNV-C/D ES-1-2D-21-UNV-D

GE226-MVPS-3W

C2642UNVSE/BE/BES C226SR120BE C226SR277BE

ICF-2526-H1-LD REL-1T32 VEL-1T32 REL-1T42 VEL-1T42

QTP 2X26/UNV QTP 1/2XCF/UNV

PSM226CQMY

ES-2/1-CFQ-26-UNV-C/D ES-1-CFH-42/32/26-UNV-C/D ES-1-T5C-40/22-UNV-D

T12 Magnetic

GE

T12 Electronic & High Output

CFL – Cross Reference Chart

Sign Compact Fluorescent 17-3

HID Electronic & Electromagnetic

See page E-1 for warranty information.


Specifications: Multivolt ProLine速 CFL Quick Reference Chart

Lamp Type

CFQ13W/GX4q

CFTR13W/GX24q CFQ18W/GX24q CFTR18W/GX24q

CFS10W/GR10q GEC213-MVPS-xx

CFS16W/GR10q

GFQ18W/G24q

CFTR18W/GX24q CFQ26W/G24q GFTR26W/GX24q

CFS21W/GR10q CFS16W/GR10q GEC218-MVPS-xx

CFS28W/GR10q

CFQ26W/G24q

CFTR26W/GX24q CFTR42W/GX24q CFT32W/GX24q CFS21W/GR10q FT24W/2G11 GEC226-MVPS-xx

FC16T9/40W

GEC242-MVPS-xx

CFT42W/GX24q

17-4

SE BES (Side and (Bottom Bottom Exit with # of Lamps Input Volts Entry) Studs) 120 2 277 120 1 177 120 2 277 120 1 277 120 1 277 120 1 277 120 2 277 120 1 277 120 1 277 71429 71428 120 2 277 120 1 277 120 2 277 120 1 277 120 1 277 120 1 277 120 2 277 120 1 277 120 2 277 120 1 277 71433 71432 120 2 277 120 1 277 120 2 277 120 1 277 120 1 277 120 1 277 120 2 277 120 2 277 120 1 277 71444 71443 120 2 277 71440 71439

3W (3-Way Kit) Input Watts Line 足Current 29 0.25 29 0.11 16 0.16 16 0.06 29 0.25 29 0.11 16 0.16 16 0.06 20 0.17 20 0.07 20 0.17 20 0.07 23 0.19 23 0.09 13 0.11 13 0.05 17 0.14 71430 17 0.06 35 0.3 35 0.13 19 0.16 19 0.07 39 0.33 39 0.14 20 0.17 20 0.08 28 0.24 28 0.10 28 0.24 28 0.10 40 0.33 40 0.14 20 0.16 20 0.07 37 0.31 37 0.13 31 0.26 31 0.11 71434 51 0.43 51 0.19 27 0.23 27 0.10 54 0.45 54 0.20 29 0.24 29 0.11 46 0.38 46 0.17 36 0.031 36 0.013 51 0.042 51 0.18 48 0.41 48 0.18 43 0.36 43 0.16 71445

Power Factor 0.99 0.99 0.96 0.96 0.99 0.99 0.96 0.96 0.99 0.97 0.99 0.97 0.97 0.97 0.96 0.96 0.96 0.96 0.99 0.99 0.97 0.97 0.97 0.99 0.97 0.97 0.99 0.96 0.99 0.96 0.99 0.99 0.97 0.97 0.99 0.99 0.99 0.97 0.99 0.99 0.98 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.99 0.99 0.99 0.99 0.97

Max THD% 10 10 10 10 10 10 10 10 12 12 12 12 11 11 14 14 12 12 10 10 10 10 10 10 10 10 12 12 12 12 10 10 15 15 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Ballast Factor 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.95 0.95 1.05 1.05 1.0 1.0 0.95 0.95 1.0 1.0 1.05 1.05 1.05 1.05 1.0 1.0 1.0 1.0 0.91 0.91 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.10 1.10 0.98 0.98 0.98 0.98 1.12 1.12 0.93 0.93 1.00 1.00

Ballast Efficiency Factor 3.45 3.45 6.25 6.25 3.45 3.45 6.25 6.25 5.00 5.00 5.00 5.00 4.13 4.13 8.08 8.08 5.88 5.88 2.71 2.71 5.26 5.26 2.69 2.69 5.25 5.25 3.57 3.57 3.57 3.57 2.28 2.28 4.5 4.5 2.70 2.70 3.23 3.23 1.96 1.96 3.7 3.7 1.85 1.85 3.79 3.79 2.13 2.13 2.72 2.72 2.20 2.20 1.94 1.94 2.33 2.33

71441

See page E-1 for warranty information.


ProLine® CFL Electronic Ballasts Compact Fluorescent Ballasts For 13 – 70W T4 CFL Lamps 71428 – GEC213-MVPS-BES 71429 – GEC213-MVPS-SE 71430 – GEC213-MVPS-3W

T8 Instant Start

• Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring

ProLine® CFL Electronic Ballasts 2 or 1 – CFQ13W/G24q 120-227V ProLine® PS

General characteristics Electronic – Program / Rapid Start Programmed start Series 10% 104°F (40°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected, Universal voltage

Additional Info

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

5.0 in (127 mm) 2.4 in (61 mm) 1.0 in (25 mm) 4.63 in (118 mm) 2.4 in (61 mm) 0.57 lbs Dual Entry (SE/BE, BES, 3W) 20 ft 18 AWG

Programmed Start Dimming

Wiring diagram – CFL 1-2 – see example on page 17-14 Case dimensions – Ref Drawing -13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge

T8 Programmed Start

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating

Order information 10 Pack 71428, 71429, 71430

Pallet Pack

DIY Pack

Ballasts

gelighting.com

IP Pack

Specifications by lamp and wattage

Safety and performance

FCC Part 18 Class B at 120 Volts

UL Class P

cUL

71432 – GEC218-MVPS-BES 71433 – GEC218-MVPS-SE 71434 – GEC218-MVPS-3W

Ballast Efficacy Factor 3.23 3.23 3.33 3.33 3.45 3.45 6.25 6.25 3.45 3.45 6.25 6.25

Power Factor % (>=) 99 98 99 98 99 99 96 96 99 99 96 96

Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10

Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29

UL Listed

• Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring

T12 Magnetic

ProLine® CFL Electronic Ballasts 2 or 1 – CFQ18W/G24q 120-227V ProLine® PS

Dimensions

General characteristics Electronic – Program / Rapid start Programmed start Series 10% 104°F (40°C) 70°C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage

Wiring diagram – CFL 1-2 – see example on page 17-14 Case dimensions – Ref Drawing -13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

5.0 in (127 mm) 2.4 in (61 mm) 1.0 in (25 mm) 4.63 in (118 mm) 2.4 in (61 mm)

Sign

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

T12 Electronic & High Output

# of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 31 0.26 A 1.00 2 277 31 0.12 A 1.00 2 120 30 0.25 A 1.00 F13T5 2 277 30 0.11 A 1.00 2 120 29 0.25 A 1.00 2 277 29 0.11 A 1.00 CFTR13W/ 1 120 16 0.16 A 1.00 GX24q 1 277 16 0.06 A 1.00 2 120 29 0.25 A 1.00 2 277 29 0.11 A 1.00 1 120 16 0.16 A 1.00 CFQ13W/G24q 1 277 16 0.06 A 1.00 Other compatible lamps: CFQ18W/G24q, CFTR18W/GX24q, CFS16W/GR10q, CFS10W/GR10q F14T5

T5 Electronic Programmed Start

Lamp

1.10 lbs Dual Entry (SE/BE, BES, 3W) 20 ft 18 AWG

Order information 10 Pack 71432, 71433, 71434

Pallet Pack

DIY Pack

IP Pack

Safety and performance

FCC Part 18 Class B at 120 volts

See page E-1 for warranty information.

UL Class P

cUL

Ballast Efficacy Factor 2.28 2.28 4.50 4.50 2.69 2.69 5.25 5.25 2.70 2.70

Power Factor % (>=) 99 99 97 97 97 97 97 97 99 99

Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

THD (<=) 10 10 15 15 10 10 10 10 10 10

Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29

UL Listed

17-5

HID Electronic & Electromagnetic

# of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 40 0.33 A 0.91 2 277 40 0.14 A 0.91 CFS21W/ 1 120 20 0.16 A 0.9 GR10q 1 277 20 0.07 A 0.9 2 120 39 0.33 A 1.05 2 277 39 0.14 A 1.05 CFTR18W/ 1 120 20 0.17 A 1.05 GX24q 1 277 20 0.08 A 1.05 CFS16W/ 2 120 37 0.31 A 1.00 GR10q 2 277 37 0.13 A 1.00 Other compatible lamps: CFTR26W/GX24q, CFQ26W/G24q, CFS28W/GR10q, CFQ18W/G24q

Compact Fluorescent

Specifications by lamp and wattage Lamp


ProLine® CFL Electronic Ballasts Compact Fluorescent Ballasts For 13 – 70W T4 CFL Lamps 71443 – GEC226-MVPS-BES 71444 – GEC226-MVPS-SE 71445 – GEC226-MVPS-3W

• Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring

ProLine® CFL Electronic Ballasts 2 – CFQ26W, FT24 or 1 – 24W CFTR32 120-227V ProLine® PS

General characteristics

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Electronic – Program / Rapid start Programmed start Series 10% 104°F (40°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto restart, Thermally protected, Universal voltage

Wiring diagram – CFL 1-2 – see example on page 17-14 Case dimensions – Ref Drawing 13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

5.0 in (127 mm) 2.4 in (61 mm) 1.0 in (25 mm) 4.63 in (118 mm) 2.4 in (61 mm) 0.57 lbs Dual Entry (SE/BE, BES, 3W) 12 ft 18 AWG

Order information 10 Pack 71443, 71444, 71445

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage Lamp

# of Lamps Line Volts System Watts Nom. Line Current 2 120 54 0.45 A 2 277 54 0.20 A 1 120 29 0.24 A CFTR26W/GX24q 1 277 29 0.11 A 1 120 51 0.43 A 1 277 51 0.19 A 2 120 27 0.23 A CFQ26W/G24q 2 277 27 0.10 A 1 120 46 0.38 A CFTR42W/GX24q 1 277 46 0.17 A 1 120 36 0.31 A CFTR32W/GX24q 1 277 36 0.13 A Other compatible lamps: F24T5/HO, CFS21W/GR10q, FT24W/2G11, FC16T9/40W

Safety and performance

17-6

FCC Part 18 Class B at 120 volts

System Ballast Factor 1.00 1.00 1.10 1.10 1.00 1.00 1.00 1.00 0.98 0.98 98.00 0.98

UL Class P

UL Listed

Ballast Efficacy Factor 1.85 1.85 3.79 3.79 1.96 1.96 3.70 3.70 2.13 2.13 272.22 2.72

Power Factor % (>=) 99 99 98 98 99 99 98 98 98 98 98 98

Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5

THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10

Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29

cUL

See page E-1 for warranty information.


ProLine® CFL Electronic Ballasts Compact Fluorescent Ballasts For 13 – 70W T4 CFL Lamps 71439 – GEC242-MVPS-BES (replaces 47506) 71440 – GEC242-MVPS-SE (replaces 47509) 71441 – GEC242-MVPS-3W

T8 Instant Start

• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case

ProLine® CFL Electronic Ballasts 2 – 42/36/32/28/26/24 watt 120-277V Proline® PS

General characteristics Electronic – Program / Rapid start Programmed start Series 10% 122°F (50°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto restart, Thermally protected, Universal voltage

Electrical characteristics Supply Current Frequency

5 in (127 mm) 3.0 in (76 mm) 1.38 in (35 mm) 4.63 in (118 mm)

0.90 lbs Dual Entry (SE/BE, BES, 3W)

Programmed Start Dimming

Wiring diagram – CFL 5 – see example on page 17-14 Case dimensions – Ref Drawing 13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type

T8 Programmed Start

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

50 Hz/60 Hz

Order information 10 Pack 71439, 71440, 71441

Pallet Pack

DIY Pack

IP Pack

Specifications by lamp and wattage Lamp

CFTR32W/GX24q CFQ26W/G24q, CFTR26W/ GX24q

FT39W/2G11

FC12T5 40W

CFTR57W/GX24q CFTR70W/GX24q FT55W/2G11

FT40W/2G11

FT24W/2G11

FC9T5+FC12T5 CFS55W/ GRY10q-3

Safety and performance

FCC Part 18 Class B at 120 volts

UL Listed

Power Factor % (>=) 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.96 0.99 0.97 0.99 0.95 0.99 0.98 0.99 0.94 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.95 0.99 0.97 0.99 0.93 0.99 0.97 0.99 0.97 0.99 0.96 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.94 0.99 0.97 0.99 0.92 0.99 0.98 0.99 0.93 0.99 0.98 0.99 0.94

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD (<=) 10 10 10 10 10 12 10 12 10 12 10 12 10 10 10 15 10 10 10 12 10 10 10 15 10 12 10 12 10 12 10 12 10 12 10 10 10 12 10 10 10 15 10 12 10 15 10 10 10 15 10 10 10 10

Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18

cUL

17-7

HID Electronic & Electromagnetic

See page E-1 for warranty information.

UL Class P

Ballast Efficacy Factor 1.14 1.08 2.13 2.13 1.51 1.51 2.29 2.29 1.67 1.67 3.12 3.12 1.25 1.27 2.45 2.44 1.16 1.16 2.22 2.22 1.13 1.15 2.24 2.24 2.11 2.11 3.97 3.92 1.72 1.72 1.37 1.37 1.65 1.66 1.16 1.16 2.22 2.22 1.25 1.27 2.45 2.44 1.85 1.85 3.56 3.48 1.60 1.62 2.94 2.94 1.34 1.34 1.48 1.53

Compact Fluorescent

CFS28W/GR10q

System Ballast Factor 1.00 1.00 1.00 1.00 0.95 0.95 0.96 0.96 0.90 0.90 1.00 1.00 0.78 0.79 0.80 0.80 0.95 0.95 1.00 1.00 0.80 0.81 0.84 0.84 1.10 1.10 1.10 1.11 1.0 1.0 1.0 1.0 0.71 0.72 0.95 0.95 1.00 1.00 0.78 0.79 0.80 0.80 1.00 1.00 0.92 0.92 0.95 0.97 1.00 1.00 0.90 0.90 0.49 0.49

Sign

FT36W/2G11

Nom. Line Current 0.77 A 0.38 A 0.40 A 0.18 A 0.53 A 0.23 A 0.35 A 0.13 A 0.45 A 0.21 A 0.27 A 0.13 A 0.52 A 0.23 A 0.27 A 0.13 A 0.69 A 0.30 A 0.37 A 0.17 A 0.59 A 0.26 A 0.31 A 0.14 A 0.44 A 0.19 A 0.23 A 0.11 A 0.49 A 0.22 A 0.61 A 0.27 A 0.36 A 0.16 A 0.69 A 0.30 A 0.37 A 0.17 A 0.52 A 0.23 A 0.27 A 0.13 A 0.45 A 0.20 A 0.22 A 0.10 A 0.50 A 0.22 A 0.29 A 0.14 A 0.55 A 0.25 A 0.28 A 0.13 A

T12 Magnetic

FC9T5 22W

System Watts 94 93 47 47 63 63 42 42 54 54 32 32 63 62 33 33 82 82 45 45 70 70 37 37 52 52 28 28 58 58 73 73 43 44 82 82 45 45 63 62 33 33 54 54 26 27 60 60 34 34 67 67 33 32

T12 Electronic & High Output

CFM36W/2G10

Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277

T5 Electronic Programmed Start

CFTR42W/GX24q

# of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1 1 1 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1+1 1+1 1 1

Ballasts

gelighting.com


High-Lumen Biax® UltraMax® Instant Start Compact Fluorescent Ballasts 75948 – GEC140MAX-A

• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • Instant start electronic ballast for long lamp starting cycles and low initial cost • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset

High-Lumen Biax® UltraMax® Instant Start 1 – FT40W-25W/2G11 Biax - 120-277V UltraMax® Instant Start

General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Dimensions Electronic – Standard Instant Start Instant start

Wiring diagram – CFL IS1 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black

10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected

Electrical characteristics Supply Current Frequency

50 Hz /60 Hz

Order information 10 Pack 75948

Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 10 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 25 in (635 mm)

Specifications by lamp and wattage Lamp FT40W/4P FT40W/28W/4P FT40W/25W/4P F32T8 F28T5/HE

# of Lamps 1 1 1 1 1 1 1 1 1 1

Safety and performance

17-8

Line Volts 120 277 120 277 120 277 120 277 120 277

System Watts 38 38 34 34 31 31 33 33 36 36

UL Type 1 Outdoor

Nom. Line Current 0.32 A 0.14 A 0.29 A 0.13 A 0.25 A 0.12 A 0.27 A 0.13 A 0.30 A 0.14 A UL Type HL

Ballast Factor 0.90 0.90 1.00 1.00 1.00 1.00 0.94 0.94 1.10 1.10

FCC – CLASS A Non-Consumer

Power Factor % (>=) 99 95 99 95 99 90 99 95 99 95 UL Class P

CSA

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD (<=) 10 10 10 10 10 10 10 10 10 10

Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18

UL Listed

See page E-1 for warranty information.


High-Lumen Biax® UltraMax® Instant Start Compact Fluorescent Ballasts 71435 – GEC240MAX-A High-Lumen Biax® UltraMax® Instant Start 2 or 1 – FT40W-25W/2G11 Biax - 120-277V UltraMax® Instant Start

General characteristics

Dimensions Electronic – High Efficiency Instant Start Instant start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected

Electrical characteristics Supply Current Frequency

50 Hz /60 Hz

Order information Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 12 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 25 in (635 mm)

Programmed Start Dimming

Wiring diagram – CFL IS2 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black

T8 Programmed Start

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

10 Pack 71435

T8 Instant Start

• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • Energy saving, high efficiency instant start electronic ballast (> 90%) • Instant start electronic ballast for long lamp starting cycles and low initial cost • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset

Specifications by lamp and wattage Lamp

FT40W/28W/4P

FT40W/25W/4P

F28T5/HE

Safety and performance

System Watts 69 68 42 42 63 62 38 38 58 57 35 35 63 62 38 38 69 68 41 41

UL Type 1 Outdoor

Nom. Line Current 0.58 A 0.25 A 0.35 A 0.16 A 0.54 A 0.23 A 0.32 A 0.14 A 0.50 A 0.21 A 0.29 A 0.13 A 0.54 A 0.23 A 0.32 A 0.14 A 0.59 A 0.25 A 0.35 A 0.15 A UL Type HL

Ballast Factor 0.90 0.90 1.00 1.00 1.00 1.00 1.11 1.11 1.00 1.00 1.15 1.15 0.94 0.94 1.08 1.08 1.10 1.10 1.26 1.26

FCC – CLASS A Non-Consumer

Power Factor % (>=) 99 95 99 95 99 95 99 95 99 90 99 95 99 95 99 95 99 95 99 95 UL Class P

CSA

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD (<=) 10 10 10 15 10 10 10 15 10 10 10 15 10 10 10 15 10 10 10 15

Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18

T12 Electronic & High Output

F32T8

Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277

T5 Electronic Programmed Start

FT40W/4P

# of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1

Ballasts

gelighting.com

UL Listed

T12 Magnetic Sign Compact Fluorescent 17-9

HID Electronic & Electromagnetic

See page E-1 for warranty information.


High-Lumen Biax® UltraMax® Instant Start Compact Fluorescent Ballasts 71436 – GEC340MAX-A

• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • Energy saving, high efficiency instant start electronic ballast (> 90%) • Instant start electronic ballast for long lamp starting cycles and low initial cost • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset

High-Lumen Biax® UltraMax® Instant Start 3 – FT40W-25W/2G11 Biax - 120-277V UltraMax® Instant Start

General characteristics

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Electronic – High Efficiency Instant Start Instant start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected

Wiring diagram – CFL IS3– see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black

Electrical characteristics Supply Current Frequency

50 Hz /60 Hz

Order information 10 Pack 71436

Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 12 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 25 in (635 mm)

Specifications by lamp and wattage Lamp

FT40W/4P

FT40W/28W/4P

FT40W/25W/4P

F32T8

F28T5/HE

# of Lamps 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2

Safety and performance

17-10

Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277

System Watts 100 99 76 75 93 91 70 69 85 84 64 63 92 90 69 68 102 100 76 75

UL Type 1 Outdoor

Nom. Line Current 0.86 A 0.36 A 0.65 A 0.27 A 0.79 A 0.33 A 0.59 A 0.25 A 0.73 A 0.31 A 0.53 A 0.23 A 0.78 A 0.33 A 0.59 A 0.25 A 0.87 A 0.37 A 0.66 A 0.28 A UL Type HL

Ballast Factor 0.90 0.90 0.98 0.98 1.00 1.00 1.07 1.07 1.00 1.00 1.11 1.11 0.94 0.94 1.03 1.03 1.10 1.10 1.19 1.19

FCC – CLASS A Non-Consumer

Power Factor % (>=) 99 99 99 95 99 95 99 95 99 95 99 95 99 95 99 95 99 99 99 95 UL Class P

CSA

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10

Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18

UL Listed

See page E-1 for warranty information.


High-Lumen Biax® UltraStart® Programmed Start Compact Fluorescent Ballasts High-Lumen Biax® UltraStart® Programmed Start for 40W 2 or 1 – FT40W/2G11 Biax - 120-277V UltraStart® Programmed Start

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Electronic – Program / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage

Electrical characteristics Supply Current Frequency

50 Hz /60 Hz

Order information 10 Pack 71437

Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 12 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm)

Programmed Start Dimming

Wiring diagram – CFL PS2 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White

T8 Programmed Start

General characteristics

• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Parallel Lamp Operation keeps lights on when one lamp fails • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset • Starting time visually the same as instant start

T8 Instant Start

71437 – GEC240MVPS-A

Ballasts

gelighting.com

Specifications by lamp and wattage

FT40W/4P

# of Lamps 2 2 1 1

Line Volts 120 277 120 277

Safety and performance

System Watts 70 69 42 42

UL Type 1 Outdoor

Nom. Line Current 0.59 A 0.25 A 0.36 A 0.17 A UL Type HL

Ballast Factor 0.90 0.90 1.04 1.04

FCC – CLASS A Non-Consumer

High-Lumen Biax® UltraStart® Programmed Start for 25W and 28W General characteristics

Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18

UL Listed

• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Parallel Lamp Operation keeps lights on when one lamp fails • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Electronic – Program / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage

50 Hz /60 Hz

Order information Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 10 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm)

Sign

Wiring diagram – CFL PS2 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White

Electrical characteristics Supply Current Frequency

10 Pack 75950

CSA

THD (<=) 10 10 10 15

T12 Magnetic

2 or 1 – FT25W/2G11 Biax - 120-277V UltraStart® Programmed Start

UL Class P

Crest Factor (<=) 1.7 1.7 1.7 1.7

T12 Electronic & High Output

75950 – GEC225MVPS-A

Power Factor % (>=) 99 95 99 95

T5 Electronic Programmed Start

Lamp

FT40W/28W/4P

FT40W/25W/4P

# of Lamps 2 2 1 1 2 2 1 1

See page E-1 for warranty information.

System Watts 62 61 40 40 57 56 36 36

UL Type 1 Outdoor

Nom. Line Current 0.53 A 0.23 A 0.33 A 0.15 A 0.48 A 0.21 A 0.30 A 0.14 A UL Type HL

Ballast Factor 1.00 1.00 1.17 1.17 1.00 1.00 1.22 1.22

FCC – CLASS A Non-Consumer

Power Factor % (>=) 99 95 99 95 99 95 99 95 UL Class P

CSA

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD (<=) 10 10 10 15 10 10 10 15

Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18

UL Listed

17-11

HID Electronic & Electromagnetic

Safety and performance

Line Volts 120 277 120 277 120 277 120 277

Compact Fluorescent

Specifications by lamp and wattage Lamp


CFL Magnetic Ballasts Compact Fluorescent Ballasts For 5 – 26W Preheat CFL Lamps 87533 – GEM1CF13PH120

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

ProLine® CFL Magnetic Ballasts 1 – CFT/Q13W/GX23 Pre Heat 120 (4111H2P)

General characteristics

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Thermally protected

Electrical characteristics Supply Current Frequency

60 Hz

Order information 10 Pack 87533

Pallet Pack

DIY Pack

IP Pack

Wiring diagram – CFL 21 – see example on page 17-14 Case dimensions – Ref Drawing 2 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Black

3.0 in (77 mm) 1.25 in (32 mm) 1.75 in (44 mm) 3.0 in (77 mm) 2.75 in (70 mm) 0.2 in (6 mm) 0.62 lbs Side 10 ft 18 AWG Length (± 1 in) 7 in (178 mm) 9 in (229 mm)

Specifications by lamp and wattage Lamp CFQ13W/2P CFT13W/2P

# of Lamps 1 1

Line Volts 120 120

System Watts 15 15

Safety and performance

Nom. Line Current 0.25 A 0.25 A

UL Type HL

UL Class P

System Ballast Factor 0.90 0.90

cUL Listed

Ballast Efficacy Factor 6.00 6.00

Power Factor % (>=) 50 50

Crest Factor (<=) 1.7 1.7

THD (<=) 10 10

Min. Starting Temp (°F/°C) 50 / 10 50 / 10

UL Listed

87655 – GEM2CF13PH277

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

CFL Magnetic Ballasts 2 – CFT/Q13W/GX23 Pre Heat 277 (4214PBES)

General characteristics

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected

Electrical characteristics Supply Current Frequency

60 Hz

Order information 10 Pack 87655

Pallet Pack

DIY Pack

IP Pack

Wiring diagram – CFL 9 – see example on page 17-14 Case dimensions – Ref Drawing 8 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Black White

4.75 in (121 mm) 2.1 in (56 mm) 1.6 in (41 mm) 4.75 in (121 mm) 4.375 in (111 mm) 0.2 in (6 mm) 1.60 lbs Bottom 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm)

Specifications by lamp and wattage Lamp CFQ13W/2P CFT13W/2P

# of Lamps 2 2

Line Volts 277 277

Safety and performance

17-12

System Watts 32 32

Nom. Line Current 0.12 A 0.12 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor 0.90 0.90 UL Class P

Ballast Efficacy Factor 2.81 2.81

Power Factor % (>=) 95 95

Crest Factor (<=) 1.7 1.7

THD (<=) 30 30

Min. Starting Temp (°F/°C) 25 / -4 25 / -4

UL Listed

See page E-1 for warranty information.


CFL Magnetic Ballasts Compact Fluorescent Ballasts For 36 – 40W CFL Lamps 87623 – GEM2FT36RS120

T8 Instant Start

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

CFL Magnetic Ballasts 2 – FT36W/2G11 RS 120 (4150P)

General characteristics

Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected

Electrical characteristics Supply Current Frequency

60 Hz

Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 2.3 in (60 mm) 1.5 in (39 mm) 8.8 in (226 mm) 1.6 in (43 mm) 0.3 in (8 mm) 3.38 lbs Side 10 ft 18 AWG Length (± 1 in) 20 in (508 mm) 20 in (508 mm) 20 in (508 mm)

Specifications by lamp and wattage Lamp FT36W/4P

# of Lamps 2

Line Volts 120

System Watts 78

Safety and performance

Nom. Line Current 0.70 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor 0.96 UL Class P

Ballast Efficacy Factor 1.23

Power Factor % (>=) 93

Crest Factor (<=) 1.7

THD (<=) 20

Min. Starting Temp (°F/°C) 50 / 10

Programmed Start Dimming

Order information 10 Pack 87623

Wiring diagram – CFL 5 – see example on page 17-14 Case dimensions – Ref Drawing ST – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow

T8 Programmed Start

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Ballasts

gelighting.com

UL Listed

T5 Electronic Programmed Start T12 Electronic & High Output

87625 – GEM2FT40RS120

• Magnetic compact fluorescent ballast construction for all general fluorescent lighting

CFL Magnetic Ballasts 2 – FT40W/2G11RS RS 120 (4152P)

Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected

Electrical characteristics Supply Current Frequency

60 Hz

Pallet Pack

DIY Pack

IP Pack

9.5 in (241 mm) 2.3 in (60 mm) 1.5 in (39 mm) 8.8 in (226 mm) 1.6 in (43 mm) 0.3 in (8 mm) 3.38 lbs Side 10 ft 18 AWG Length (± 1 in) 20 in (508 mm) 20 in (508 mm) 20 in (508 mm)

Sign

Order information 10 Pack 87625

Wiring diagram – CFL 5 – see example on page 17-14 Case dimensions – Ref Drawing ST – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow

T12 Magnetic

General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Specifications by lamp and wattage Lamp FT40W/4P

# of Lamps 2

Line Volts 120

UL Type 1 Outdoor

UL Type HL

System Ballast Factor 1.00 UL Class P

Ballast Efficacy Factor 1.23

Power Factor % (>=) 98

Crest Factor (<=) 1.7

THD (<=) 20

Min. Starting Temp (°F/°C) 50 / 10

UL Listed

17-13

HID Electronic & Electromagnetic

See page E-1 for warranty information.

Nom. Line Current 0.68 A

Compact Fluorescent

Safety and performance

System Watts 81


Wiring Diagrams Compact Fluorescent Ballasts CFL 21

CFL 9

CFL 5

CFL 1-2

17-14

See page E-1 for warranty information.


Wiring Diagrams Compact Fluorescent Ballasts

Line

Black White

BALLAST

Blue Red

Line

Black White

BALLAST

T8 Instant Start

CFL IS2

CFL IS1

Ballasts

gelighting.com

Blue Blue Red

T8 Programmed Start Programmed Start Dimming

Line

Black White

CFL PS2 BALLAST

Blue Blue Blue Red

Line

Black White

BALLAST

T5 Electronic Programmed Start

CFL IS3

Blue Yellow Red

T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 17-15

HID Electronic & Electromagnetic

See page E-1 for warranty information.


Case Dimensions Compact Fluorescent Ballasts -A

8

2

13

ST

17-16

See page E-1 for warranty information.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.