Table of Contents Compact Fluorescent Ballasts
Ballasts
gelighting.com
T8 Instant Start
Understanding Compact Fluorescent Ballasts...........17-2 ProLine® CFL Electronic Ballasts For 13 – 70W T4 CFL Lamps................................................. 17-5
T8 Programmed Start
High-Lumen Biax® UltraMax® Instant Start Ballasts.......................................................17-8 High-Lumen Biax® UltraStart® Programmed Start Ballasts..........................................17-11
Programmed Start Dimming
CFL Magnetic Ballasts For 5 – 26W Preheat CFL Lamps......................................17-12 For 36 – 40W CFL Lamps......................................................17-13 Wiring Diagrams.............................................................17-14 Case Dimensions............................................................17-16
T5 Electronic Programmed Start T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 17-1
HID Electronic & Electromagnetic
See page E-1 for warranty information.
Understanding Compact Fluorescent Ballasts GE compact fluorescent (CFL) ballasts provide energy saving alternatives to halogen, incandescent or HID light sources. GE Multivolt ProLine® CFL programmed start ballasts combine universal voltage (108-305V) technology with multi-lamp capability, dual entry color-coded connectors and ultra system reliability to create an industry leading CFL solution for commercial and residential applications. UltraMax® and UltraStart® High Lumen Biax® ballasts with the High Lumen WattMiser® Biax® lamp provides the perfect solution for high efficiency and high lumen output in a small space. UltraMax® Instant Start Ballasts: • For use in long burn cycles (>10 hr cycles) to maintain lamp life • High efficiency (>90%) design
• Universal voltage (120-277V) • Striation control circuitry • Small compact housing
UltraStart® Programmed Start Ballasts: • For use in shorter burn cycles (<3 hr cycles) to extend lamp life • High efficiency (>90%) cathode cutout design • Universal voltage (120-277V) • Striation control circuitry
• Small compact housing • Parallel lamp operation • <700ms fast starting time •B allasts available for both F40/30W and F40/25W lamps
Multivolt ProLine® CFL ballasts are offered in three different configurations: 1) -SE description – dual entry (side or bottom) connectors, 2) -BES – bottom entry with studs for mounting to junction boxes and 3) -3W – 3-way mounting kits that allow you to have all three mounting options with one kit. Multivolt ProLine® CFL ballasts come with a five-year ballast and one-year lamp limited warranty. These ballasts also meet the EPA’s ENERGY STAR® fixture program requirements with a Consumer Class B EMI rating for residential applications, as well as a high power factor ballast design. Use the GE Multivolt ProLine® CFL Multi-Lamp compatibility chart (page 17-3) to find the right ballast for your need. ProLine® CFL Date Code System Date Code Format: 01 200801 = Week2008 = Year UltraMax® and UltraStart® Biax® ballasts have the same date code system as all linear fluorescent ballasts.
GE Compact Fluorescent Ballast nomenclature
G E C 2 1 3 - M V P S - S E GE Compact Ballast Max number of lamps and Primary Lamp type
17-2
MV = Multivolt (108 to 305 volts) UNV = Universal Voltage (Multi-Voltage) 120 or 277 = voltage
SE = Side & Bottom Entry BES = Bottom Entry with Studs 3W = 3-Way Kit (SE, BE, BES) IP = Individual Pack
PS = Programmed Start SI = Series Instant Start PH = Preheat. RS = Rapid Start RH = less than 20% THD See page E-1 for warranty information.
GE Multivolt ProLine® CFL Multi-Lamp Capability
T5
GEC242MVPS
X X X
X X
X
X
GECX40-MAX
X X X X X X X X X X X X
X X X
X X X X X X X
X
T5 Electronic Programmed Start
2D
X X X
GEC226-MVPS
Programmed Start Dimming
FT TT5
GEC218-MVPS
T8 Programmed Start
T5 Circleline
GEC213-MVPS X X X
T8 Instant Start
T4
Lamp Type 1 x 13W (CFQ/G24q, CFTR/GX24q) 2 x 13W (CFQ/G24q, CFTR/GX24q) 1 x 18W (CFQ/G24q, CFTR/GX24q) 2 x 18W (CFQ/G24q, CFTR/GX24q) 1 x 26W (CFQ/G24q, CFTR/GX24q) 2 x 26W (CFQ/G24q, CFTR/GX24q) 1 x 32W (CFQ/G24q, CFTR/GX24q) 2 x 32W (CFQ/G24q, CFTR/GX24q) 1 x 42W (CFQ/G24q, CFTR/GX24q) 2 x 42W (CFQ/G24q, CFTR/GX24q) 1 x 22W (FC9T5) 1 x 22W (FC9T5) 1 x 22W + 1 x 40W (FC9T5 + FC12T5) 1 x FC16T9 2 x 24 / 27W (FT/2G11) 1 x FT36W (2G11) 2 x FT36W (2G11) 1 x 40W (FT/2G11) & Energy Saving 28W & 25W 2 x 40W (FT/2G11) & Energy Saving 28W & 25W 3 x 40W (FT/2G11) & Energy Saving 28W & 25W 1 x 10W (CFS/GR10q) 2 x 10W (CFS/GR10q) 1 x 16W (CFS/GR10q) 2 x 16W (CFS/GR10q) 1 x 21W (CFS/GR10q) 2 x 21W (CFS/GR10q) 1 x 28W (CFS/GR10q) 2 x 28W (CFS/GR10q) 1 x 38W (CFS/GR10q) 2 x 38W (CFS/GR10q) 1 x 57W (CFTR/GX24q) 1 x 70W (CFTR/GX24q)
Ballasts
gelighting.com
X X X X X
Universal
Advance
Osram
Robertson
ESI
GE213-MVPS-3W
C213UNVSE/BE/BES
ICF-2513-H1-LD
QTP 1/2X13CF/UNV
PSM213CQMY
ES-2/1-CFQ-13/10-UNV-C/D ES-1-2D-16/10-UNV-D
GE218-MVPS-3W
C218UNVSE/BE/BES
ICF-2518-H1-LD REL-2Q18 VEL-2Q18 R-2Q18-4P-TP V-2Q18-4P-TP
QTP 1/2X18CF/UNV
PSM218CQMY
ES-2/1-CFQ-18-UNV-C/D ES-1-2D-21-UNV-D
GE226-MVPS-3W
C2642UNVSE/BE/BES C226SR120BE C226SR277BE
ICF-2526-H1-LD REL-1T32 VEL-1T32 REL-1T42 VEL-1T42
QTP 2X26/UNV QTP 1/2XCF/UNV
PSM226CQMY
ES-2/1-CFQ-26-UNV-C/D ES-1-CFH-42/32/26-UNV-C/D ES-1-T5C-40/22-UNV-D
T12 Magnetic
GE
T12 Electronic & High Output
CFL – Cross Reference Chart
Sign Compact Fluorescent 17-3
HID Electronic & Electromagnetic
See page E-1 for warranty information.
Specifications: Multivolt ProLine速 CFL Quick Reference Chart
Lamp Type
CFQ13W/GX4q
CFTR13W/GX24q CFQ18W/GX24q CFTR18W/GX24q
CFS10W/GR10q GEC213-MVPS-xx
CFS16W/GR10q
GFQ18W/G24q
CFTR18W/GX24q CFQ26W/G24q GFTR26W/GX24q
CFS21W/GR10q CFS16W/GR10q GEC218-MVPS-xx
CFS28W/GR10q
CFQ26W/G24q
CFTR26W/GX24q CFTR42W/GX24q CFT32W/GX24q CFS21W/GR10q FT24W/2G11 GEC226-MVPS-xx
FC16T9/40W
GEC242-MVPS-xx
CFT42W/GX24q
17-4
SE BES (Side and (Bottom Bottom Exit with # of Lamps Input Volts Entry) Studs) 120 2 277 120 1 177 120 2 277 120 1 277 120 1 277 120 1 277 120 2 277 120 1 277 120 1 277 71429 71428 120 2 277 120 1 277 120 2 277 120 1 277 120 1 277 120 1 277 120 2 277 120 1 277 120 2 277 120 1 277 71433 71432 120 2 277 120 1 277 120 2 277 120 1 277 120 1 277 120 1 277 120 2 277 120 2 277 120 1 277 71444 71443 120 2 277 71440 71439
3W (3-Way Kit) Input Watts Line 足Current 29 0.25 29 0.11 16 0.16 16 0.06 29 0.25 29 0.11 16 0.16 16 0.06 20 0.17 20 0.07 20 0.17 20 0.07 23 0.19 23 0.09 13 0.11 13 0.05 17 0.14 71430 17 0.06 35 0.3 35 0.13 19 0.16 19 0.07 39 0.33 39 0.14 20 0.17 20 0.08 28 0.24 28 0.10 28 0.24 28 0.10 40 0.33 40 0.14 20 0.16 20 0.07 37 0.31 37 0.13 31 0.26 31 0.11 71434 51 0.43 51 0.19 27 0.23 27 0.10 54 0.45 54 0.20 29 0.24 29 0.11 46 0.38 46 0.17 36 0.031 36 0.013 51 0.042 51 0.18 48 0.41 48 0.18 43 0.36 43 0.16 71445
Power Factor 0.99 0.99 0.96 0.96 0.99 0.99 0.96 0.96 0.99 0.97 0.99 0.97 0.97 0.97 0.96 0.96 0.96 0.96 0.99 0.99 0.97 0.97 0.97 0.99 0.97 0.97 0.99 0.96 0.99 0.96 0.99 0.99 0.97 0.97 0.99 0.99 0.99 0.97 0.99 0.99 0.98 0.98 0.99 0.99 0.98 0.98 0.98 0.98 0.98 0.98 0.99 0.99 0.99 0.99 0.99 0.97
Max THD% 10 10 10 10 10 10 10 10 12 12 12 12 11 11 14 14 12 12 10 10 10 10 10 10 10 10 12 12 12 12 10 10 15 15 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
Ballast Factor 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 0.95 0.95 1.05 1.05 1.0 1.0 0.95 0.95 1.0 1.0 1.05 1.05 1.05 1.05 1.0 1.0 1.0 1.0 0.91 0.91 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.10 1.10 0.98 0.98 0.98 0.98 1.12 1.12 0.93 0.93 1.00 1.00
Ballast Efficiency Factor 3.45 3.45 6.25 6.25 3.45 3.45 6.25 6.25 5.00 5.00 5.00 5.00 4.13 4.13 8.08 8.08 5.88 5.88 2.71 2.71 5.26 5.26 2.69 2.69 5.25 5.25 3.57 3.57 3.57 3.57 2.28 2.28 4.5 4.5 2.70 2.70 3.23 3.23 1.96 1.96 3.7 3.7 1.85 1.85 3.79 3.79 2.13 2.13 2.72 2.72 2.20 2.20 1.94 1.94 2.33 2.33
71441
See page E-1 for warranty information.
ProLine® CFL Electronic Ballasts Compact Fluorescent Ballasts For 13 – 70W T4 CFL Lamps 71428 – GEC213-MVPS-BES 71429 – GEC213-MVPS-SE 71430 – GEC213-MVPS-3W
T8 Instant Start
• Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring
ProLine® CFL Electronic Ballasts 2 or 1 – CFQ13W/G24q 120-227V ProLine® PS
General characteristics Electronic – Program / Rapid Start Programmed start Series 10% 104°F (40°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected, Universal voltage
Additional Info
Electrical characteristics Supply Current Frequency
50 Hz/60 Hz
5.0 in (127 mm) 2.4 in (61 mm) 1.0 in (25 mm) 4.63 in (118 mm) 2.4 in (61 mm) 0.57 lbs Dual Entry (SE/BE, BES, 3W) 20 ft 18 AWG
Programmed Start Dimming
Wiring diagram – CFL 1-2 – see example on page 17-14 Case dimensions – Ref Drawing -13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge
T8 Programmed Start
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating
Order information 10 Pack 71428, 71429, 71430
Pallet Pack
DIY Pack
Ballasts
gelighting.com
IP Pack
Specifications by lamp and wattage
Safety and performance
FCC Part 18 Class B at 120 Volts
UL Class P
cUL
71432 – GEC218-MVPS-BES 71433 – GEC218-MVPS-SE 71434 – GEC218-MVPS-3W
Ballast Efficacy Factor 3.23 3.23 3.33 3.33 3.45 3.45 6.25 6.25 3.45 3.45 6.25 6.25
Power Factor % (>=) 99 98 99 98 99 99 96 96 99 99 96 96
Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10
Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29
UL Listed
• Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring
T12 Magnetic
ProLine® CFL Electronic Ballasts 2 or 1 – CFQ18W/G24q 120-227V ProLine® PS
Dimensions
General characteristics Electronic – Program / Rapid start Programmed start Series 10% 104°F (40°C) 70°C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage
Wiring diagram – CFL 1-2 – see example on page 17-14 Case dimensions – Ref Drawing -13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge
Electrical characteristics Supply Current Frequency
50 Hz/60 Hz
5.0 in (127 mm) 2.4 in (61 mm) 1.0 in (25 mm) 4.63 in (118 mm) 2.4 in (61 mm)
Sign
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
T12 Electronic & High Output
# of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 31 0.26 A 1.00 2 277 31 0.12 A 1.00 2 120 30 0.25 A 1.00 F13T5 2 277 30 0.11 A 1.00 2 120 29 0.25 A 1.00 2 277 29 0.11 A 1.00 CFTR13W/ 1 120 16 0.16 A 1.00 GX24q 1 277 16 0.06 A 1.00 2 120 29 0.25 A 1.00 2 277 29 0.11 A 1.00 1 120 16 0.16 A 1.00 CFQ13W/G24q 1 277 16 0.06 A 1.00 Other compatible lamps: CFQ18W/G24q, CFTR18W/GX24q, CFS16W/GR10q, CFS10W/GR10q F14T5
T5 Electronic Programmed Start
Lamp
1.10 lbs Dual Entry (SE/BE, BES, 3W) 20 ft 18 AWG
Order information 10 Pack 71432, 71433, 71434
Pallet Pack
DIY Pack
IP Pack
Safety and performance
FCC Part 18 Class B at 120 volts
See page E-1 for warranty information.
UL Class P
cUL
Ballast Efficacy Factor 2.28 2.28 4.50 4.50 2.69 2.69 5.25 5.25 2.70 2.70
Power Factor % (>=) 99 99 97 97 97 97 97 97 99 99
Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
THD (<=) 10 10 15 15 10 10 10 10 10 10
Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29
UL Listed
17-5
HID Electronic & Electromagnetic
# of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor 2 120 40 0.33 A 0.91 2 277 40 0.14 A 0.91 CFS21W/ 1 120 20 0.16 A 0.9 GR10q 1 277 20 0.07 A 0.9 2 120 39 0.33 A 1.05 2 277 39 0.14 A 1.05 CFTR18W/ 1 120 20 0.17 A 1.05 GX24q 1 277 20 0.08 A 1.05 CFS16W/ 2 120 37 0.31 A 1.00 GR10q 2 277 37 0.13 A 1.00 Other compatible lamps: CFTR26W/GX24q, CFQ26W/G24q, CFS28W/GR10q, CFQ18W/G24q
Compact Fluorescent
Specifications by lamp and wattage Lamp
ProLine® CFL Electronic Ballasts Compact Fluorescent Ballasts For 13 – 70W T4 CFL Lamps 71443 – GEC226-MVPS-BES 71444 – GEC226-MVPS-SE 71445 – GEC226-MVPS-3W
• Multi-voltage technology means a single ballast handles voltage from 108V to 305V • Programmed starting for extended lamp life • End-of-Lamp-Life protection • Color coded poke-in connectors simplifies wiring
ProLine® CFL Electronic Ballasts 2 – CFQ26W, FT24 or 1 – 24W CFTR32 120-227V ProLine® PS
General characteristics
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Electronic – Program / Rapid start Programmed start Series 10% 104°F (40°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto restart, Thermally protected, Universal voltage
Wiring diagram – CFL 1-2 – see example on page 17-14 Case dimensions – Ref Drawing 13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge
Electrical characteristics Supply Current Frequency
50 Hz/60 Hz
5.0 in (127 mm) 2.4 in (61 mm) 1.0 in (25 mm) 4.63 in (118 mm) 2.4 in (61 mm) 0.57 lbs Dual Entry (SE/BE, BES, 3W) 12 ft 18 AWG
Order information 10 Pack 71443, 71444, 71445
Pallet Pack
DIY Pack
IP Pack
Specifications by lamp and wattage Lamp
# of Lamps Line Volts System Watts Nom. Line Current 2 120 54 0.45 A 2 277 54 0.20 A 1 120 29 0.24 A CFTR26W/GX24q 1 277 29 0.11 A 1 120 51 0.43 A 1 277 51 0.19 A 2 120 27 0.23 A CFQ26W/G24q 2 277 27 0.10 A 1 120 46 0.38 A CFTR42W/GX24q 1 277 46 0.17 A 1 120 36 0.31 A CFTR32W/GX24q 1 277 36 0.13 A Other compatible lamps: F24T5/HO, CFS21W/GR10q, FT24W/2G11, FC16T9/40W
Safety and performance
17-6
FCC Part 18 Class B at 120 volts
System Ballast Factor 1.00 1.00 1.10 1.10 1.00 1.00 1.00 1.00 0.98 0.98 98.00 0.98
UL Class P
UL Listed
Ballast Efficacy Factor 1.85 1.85 3.79 3.79 1.96 1.96 3.70 3.70 2.13 2.13 272.22 2.72
Power Factor % (>=) 99 99 98 98 99 99 98 98 98 98 98 98
Crest Factor (<=) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10
Min. Starting Temp (°F/°C) -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29 -20/-29
cUL
See page E-1 for warranty information.
ProLine® CFL Electronic Ballasts Compact Fluorescent Ballasts For 13 – 70W T4 CFL Lamps 71439 – GEC242-MVPS-BES (replaces 47506) 71440 – GEC242-MVPS-SE (replaces 47509) 71441 – GEC242-MVPS-3W
T8 Instant Start
• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case
ProLine® CFL Electronic Ballasts 2 – 42/36/32/28/26/24 watt 120-277V Proline® PS
General characteristics Electronic – Program / Rapid start Programmed start Series 10% 122°F (50°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto restart, Thermally protected, Universal voltage
Electrical characteristics Supply Current Frequency
5 in (127 mm) 3.0 in (76 mm) 1.38 in (35 mm) 4.63 in (118 mm)
0.90 lbs Dual Entry (SE/BE, BES, 3W)
Programmed Start Dimming
Wiring diagram – CFL 5 – see example on page 17-14 Case dimensions – Ref Drawing 13 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type
T8 Programmed Start
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
50 Hz/60 Hz
Order information 10 Pack 71439, 71440, 71441
Pallet Pack
DIY Pack
IP Pack
Specifications by lamp and wattage Lamp
CFTR32W/GX24q CFQ26W/G24q, CFTR26W/ GX24q
FT39W/2G11
FC12T5 40W
CFTR57W/GX24q CFTR70W/GX24q FT55W/2G11
FT40W/2G11
FT24W/2G11
FC9T5+FC12T5 CFS55W/ GRY10q-3
Safety and performance
FCC Part 18 Class B at 120 volts
UL Listed
Power Factor % (>=) 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.96 0.99 0.97 0.99 0.95 0.99 0.98 0.99 0.94 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.95 0.99 0.97 0.99 0.93 0.99 0.97 0.99 0.97 0.99 0.96 0.99 0.98 0.99 0.96 0.99 0.98 0.99 0.94 0.99 0.97 0.99 0.92 0.99 0.98 0.99 0.93 0.99 0.98 0.99 0.94
Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
THD (<=) 10 10 10 10 10 12 10 12 10 12 10 12 10 10 10 15 10 10 10 12 10 10 10 15 10 12 10 12 10 12 10 12 10 12 10 10 10 12 10 10 10 15 10 12 10 15 10 10 10 15 10 10 10 10
Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18
cUL
17-7
HID Electronic & Electromagnetic
See page E-1 for warranty information.
UL Class P
Ballast Efficacy Factor 1.14 1.08 2.13 2.13 1.51 1.51 2.29 2.29 1.67 1.67 3.12 3.12 1.25 1.27 2.45 2.44 1.16 1.16 2.22 2.22 1.13 1.15 2.24 2.24 2.11 2.11 3.97 3.92 1.72 1.72 1.37 1.37 1.65 1.66 1.16 1.16 2.22 2.22 1.25 1.27 2.45 2.44 1.85 1.85 3.56 3.48 1.60 1.62 2.94 2.94 1.34 1.34 1.48 1.53
Compact Fluorescent
CFS28W/GR10q
System Ballast Factor 1.00 1.00 1.00 1.00 0.95 0.95 0.96 0.96 0.90 0.90 1.00 1.00 0.78 0.79 0.80 0.80 0.95 0.95 1.00 1.00 0.80 0.81 0.84 0.84 1.10 1.10 1.10 1.11 1.0 1.0 1.0 1.0 0.71 0.72 0.95 0.95 1.00 1.00 0.78 0.79 0.80 0.80 1.00 1.00 0.92 0.92 0.95 0.97 1.00 1.00 0.90 0.90 0.49 0.49
Sign
FT36W/2G11
Nom. Line Current 0.77 A 0.38 A 0.40 A 0.18 A 0.53 A 0.23 A 0.35 A 0.13 A 0.45 A 0.21 A 0.27 A 0.13 A 0.52 A 0.23 A 0.27 A 0.13 A 0.69 A 0.30 A 0.37 A 0.17 A 0.59 A 0.26 A 0.31 A 0.14 A 0.44 A 0.19 A 0.23 A 0.11 A 0.49 A 0.22 A 0.61 A 0.27 A 0.36 A 0.16 A 0.69 A 0.30 A 0.37 A 0.17 A 0.52 A 0.23 A 0.27 A 0.13 A 0.45 A 0.20 A 0.22 A 0.10 A 0.50 A 0.22 A 0.29 A 0.14 A 0.55 A 0.25 A 0.28 A 0.13 A
T12 Magnetic
FC9T5 22W
System Watts 94 93 47 47 63 63 42 42 54 54 32 32 63 62 33 33 82 82 45 45 70 70 37 37 52 52 28 28 58 58 73 73 43 44 82 82 45 45 63 62 33 33 54 54 26 27 60 60 34 34 67 67 33 32
T12 Electronic & High Output
CFM36W/2G10
Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277
T5 Electronic Programmed Start
CFTR42W/GX24q
# of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1 1 1 1 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 1+1 1+1 1 1
Ballasts
gelighting.com
High-Lumen Biax® UltraMax® Instant Start Compact Fluorescent Ballasts 75948 – GEC140MAX-A
• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • Instant start electronic ballast for long lamp starting cycles and low initial cost • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset
High-Lumen Biax® UltraMax® Instant Start 1 – FT40W-25W/2G11 Biax - 120-277V UltraMax® Instant Start
General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Dimensions Electronic – Standard Instant Start Instant start
Wiring diagram – CFL IS1 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black
10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected
Electrical characteristics Supply Current Frequency
50 Hz /60 Hz
Order information 10 Pack 75948
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 10 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 25 in (635 mm)
Specifications by lamp and wattage Lamp FT40W/4P FT40W/28W/4P FT40W/25W/4P F32T8 F28T5/HE
# of Lamps 1 1 1 1 1 1 1 1 1 1
Safety and performance
17-8
Line Volts 120 277 120 277 120 277 120 277 120 277
System Watts 38 38 34 34 31 31 33 33 36 36
UL Type 1 Outdoor
Nom. Line Current 0.32 A 0.14 A 0.29 A 0.13 A 0.25 A 0.12 A 0.27 A 0.13 A 0.30 A 0.14 A UL Type HL
Ballast Factor 0.90 0.90 1.00 1.00 1.00 1.00 0.94 0.94 1.10 1.10
FCC – CLASS A Non-Consumer
Power Factor % (>=) 99 95 99 95 99 90 99 95 99 95 UL Class P
CSA
Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
THD (<=) 10 10 10 10 10 10 10 10 10 10
Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18
UL Listed
See page E-1 for warranty information.
High-Lumen Biax® UltraMax® Instant Start Compact Fluorescent Ballasts 71435 – GEC240MAX-A High-Lumen Biax® UltraMax® Instant Start 2 or 1 – FT40W-25W/2G11 Biax - 120-277V UltraMax® Instant Start
General characteristics
Dimensions Electronic – High Efficiency Instant Start Instant start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected
Electrical characteristics Supply Current Frequency
50 Hz /60 Hz
Order information Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 12 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 25 in (635 mm)
Programmed Start Dimming
Wiring diagram – CFL IS2 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black
T8 Programmed Start
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
10 Pack 71435
T8 Instant Start
• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • Energy saving, high efficiency instant start electronic ballast (> 90%) • Instant start electronic ballast for long lamp starting cycles and low initial cost • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset
Specifications by lamp and wattage Lamp
FT40W/28W/4P
FT40W/25W/4P
F28T5/HE
Safety and performance
System Watts 69 68 42 42 63 62 38 38 58 57 35 35 63 62 38 38 69 68 41 41
UL Type 1 Outdoor
Nom. Line Current 0.58 A 0.25 A 0.35 A 0.16 A 0.54 A 0.23 A 0.32 A 0.14 A 0.50 A 0.21 A 0.29 A 0.13 A 0.54 A 0.23 A 0.32 A 0.14 A 0.59 A 0.25 A 0.35 A 0.15 A UL Type HL
Ballast Factor 0.90 0.90 1.00 1.00 1.00 1.00 1.11 1.11 1.00 1.00 1.15 1.15 0.94 0.94 1.08 1.08 1.10 1.10 1.26 1.26
FCC – CLASS A Non-Consumer
Power Factor % (>=) 99 95 99 95 99 95 99 95 99 90 99 95 99 95 99 95 99 95 99 95 UL Class P
CSA
Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
THD (<=) 10 10 10 15 10 10 10 15 10 10 10 15 10 10 10 15 10 10 10 15
Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18
T12 Electronic & High Output
F32T8
Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277
T5 Electronic Programmed Start
FT40W/4P
# of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1
Ballasts
gelighting.com
UL Listed
T12 Magnetic Sign Compact Fluorescent 17-9
HID Electronic & Electromagnetic
See page E-1 for warranty information.
High-Lumen Biax® UltraMax® Instant Start Compact Fluorescent Ballasts 71436 – GEC340MAX-A
• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • Energy saving, high efficiency instant start electronic ballast (> 90%) • Instant start electronic ballast for long lamp starting cycles and low initial cost • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset
High-Lumen Biax® UltraMax® Instant Start 3 – FT40W-25W/2G11 Biax - 120-277V UltraMax® Instant Start
General characteristics
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Electronic – High Efficiency Instant Start Instant start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected
Wiring diagram – CFL IS3– see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Red White Black
Electrical characteristics Supply Current Frequency
50 Hz /60 Hz
Order information 10 Pack 71436
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 12 ft 18 AWG Length (± 1 in) 31 in (787 mm) 31 in (787 mm) 25 in (635 mm) 25 in (635 mm)
Specifications by lamp and wattage Lamp
FT40W/4P
FT40W/28W/4P
FT40W/25W/4P
F32T8
F28T5/HE
# of Lamps 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2
Safety and performance
17-10
Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277
System Watts 100 99 76 75 93 91 70 69 85 84 64 63 92 90 69 68 102 100 76 75
UL Type 1 Outdoor
Nom. Line Current 0.86 A 0.36 A 0.65 A 0.27 A 0.79 A 0.33 A 0.59 A 0.25 A 0.73 A 0.31 A 0.53 A 0.23 A 0.78 A 0.33 A 0.59 A 0.25 A 0.87 A 0.37 A 0.66 A 0.28 A UL Type HL
Ballast Factor 0.90 0.90 0.98 0.98 1.00 1.00 1.07 1.07 1.00 1.00 1.11 1.11 0.94 0.94 1.03 1.03 1.10 1.10 1.19 1.19
FCC – CLASS A Non-Consumer
Power Factor % (>=) 99 99 99 95 99 95 99 95 99 95 99 95 99 95 99 95 99 99 99 95 UL Class P
CSA
Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
THD (<=) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18
UL Listed
See page E-1 for warranty information.
High-Lumen Biax® UltraStart® Programmed Start Compact Fluorescent Ballasts High-Lumen Biax® UltraStart® Programmed Start for 40W 2 or 1 – FT40W/2G11 Biax - 120-277V UltraStart® Programmed Start
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Electronic – Program / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage
Electrical characteristics Supply Current Frequency
50 Hz /60 Hz
Order information 10 Pack 71437
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 12 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm)
Programmed Start Dimming
Wiring diagram – CFL PS2 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White
T8 Programmed Start
General characteristics
• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Parallel Lamp Operation keeps lights on when one lamp fails • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset • Starting time visually the same as instant start
T8 Instant Start
71437 – GEC240MVPS-A
Ballasts
gelighting.com
Specifications by lamp and wattage
FT40W/4P
# of Lamps 2 2 1 1
Line Volts 120 277 120 277
Safety and performance
System Watts 70 69 42 42
UL Type 1 Outdoor
Nom. Line Current 0.59 A 0.25 A 0.36 A 0.17 A UL Type HL
Ballast Factor 0.90 0.90 1.04 1.04
FCC – CLASS A Non-Consumer
High-Lumen Biax® UltraStart® Programmed Start for 25W and 28W General characteristics
Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18
UL Listed
• Electronic compact fluorescent ballasts for all general fluorescent applications • Low-profile case • Multi-Voltage technology handles voltage from 120 to 277V • A new generation of ultra-efficient Programmed Start ballasts (> 90% efficiency) • Parallel Lamp Operation keeps lights on when one lamp fails • Anti-Striation Control for better light quality, with no striations • Lamp End-of-Life Safety Shutdown Circuit with Re-Lamping Auto-reset
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Electronic – Program / Rapid Start Programmed start Parallel 10% 105°F (41°C) 70 °C (158 °F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected, Universal voltage
50 Hz /60 Hz
Order information Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.40 lbs Side 10 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm)
Sign
Wiring diagram – CFL PS2 – see example on page 17-15 Case dimensions – Ref Drawing -A – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Blue and Red Yellow White
Electrical characteristics Supply Current Frequency
10 Pack 75950
CSA
THD (<=) 10 10 10 15
T12 Magnetic
2 or 1 – FT25W/2G11 Biax - 120-277V UltraStart® Programmed Start
UL Class P
Crest Factor (<=) 1.7 1.7 1.7 1.7
T12 Electronic & High Output
75950 – GEC225MVPS-A
Power Factor % (>=) 99 95 99 95
T5 Electronic Programmed Start
Lamp
FT40W/28W/4P
FT40W/25W/4P
# of Lamps 2 2 1 1 2 2 1 1
See page E-1 for warranty information.
System Watts 62 61 40 40 57 56 36 36
UL Type 1 Outdoor
Nom. Line Current 0.53 A 0.23 A 0.33 A 0.15 A 0.48 A 0.21 A 0.30 A 0.14 A UL Type HL
Ballast Factor 1.00 1.00 1.17 1.17 1.00 1.00 1.22 1.22
FCC – CLASS A Non-Consumer
Power Factor % (>=) 99 95 99 95 99 95 99 95 UL Class P
CSA
Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
THD (<=) 10 10 10 15 10 10 10 15
Min. Starting Temp (°F/°C) 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18 0/-18
UL Listed
17-11
HID Electronic & Electromagnetic
Safety and performance
Line Volts 120 277 120 277 120 277 120 277
Compact Fluorescent
Specifications by lamp and wattage Lamp
CFL Magnetic Ballasts Compact Fluorescent Ballasts For 5 – 26W Preheat CFL Lamps 87533 – GEM1CF13PH120
• Magnetic compact fluorescent ballast construction for all general fluorescent lighting
ProLine® CFL Magnetic Ballasts 1 – CFT/Q13W/GX23 Pre Heat 120 (4111H2P)
General characteristics
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Thermally protected
Electrical characteristics Supply Current Frequency
60 Hz
Order information 10 Pack 87533
Pallet Pack
DIY Pack
IP Pack
Wiring diagram – CFL 21 – see example on page 17-14 Case dimensions – Ref Drawing 2 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black Black
3.0 in (77 mm) 1.25 in (32 mm) 1.75 in (44 mm) 3.0 in (77 mm) 2.75 in (70 mm) 0.2 in (6 mm) 0.62 lbs Side 10 ft 18 AWG Length (± 1 in) 7 in (178 mm) 9 in (229 mm)
Specifications by lamp and wattage Lamp CFQ13W/2P CFT13W/2P
# of Lamps 1 1
Line Volts 120 120
System Watts 15 15
Safety and performance
Nom. Line Current 0.25 A 0.25 A
UL Type HL
UL Class P
System Ballast Factor 0.90 0.90
cUL Listed
Ballast Efficacy Factor 6.00 6.00
Power Factor % (>=) 50 50
Crest Factor (<=) 1.7 1.7
THD (<=) 10 10
Min. Starting Temp (°F/°C) 50 / 10 50 / 10
UL Listed
87655 – GEM2CF13PH277
• Magnetic compact fluorescent ballast construction for all general fluorescent lighting
CFL Magnetic Ballasts 2 – CFT/Q13W/GX23 Pre Heat 277 (4214PBES)
General characteristics
Dimensions
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Magnetic – Preheat Preheat Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected
Electrical characteristics Supply Current Frequency
60 Hz
Order information 10 Pack 87655
Pallet Pack
DIY Pack
IP Pack
Wiring diagram – CFL 9 – see example on page 17-14 Case dimensions – Ref Drawing 8 – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue Black White
4.75 in (121 mm) 2.1 in (56 mm) 1.6 in (41 mm) 4.75 in (121 mm) 4.375 in (111 mm) 0.2 in (6 mm) 1.60 lbs Bottom 10 ft 18 AWG Length (± 1 in) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm)
Specifications by lamp and wattage Lamp CFQ13W/2P CFT13W/2P
# of Lamps 2 2
Line Volts 277 277
Safety and performance
17-12
System Watts 32 32
Nom. Line Current 0.12 A 0.12 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor 0.90 0.90 UL Class P
Ballast Efficacy Factor 2.81 2.81
Power Factor % (>=) 95 95
Crest Factor (<=) 1.7 1.7
THD (<=) 30 30
Min. Starting Temp (°F/°C) 25 / -4 25 / -4
UL Listed
See page E-1 for warranty information.
CFL Magnetic Ballasts Compact Fluorescent Ballasts For 36 – 40W CFL Lamps 87623 – GEM2FT36RS120
T8 Instant Start
• Magnetic compact fluorescent ballast construction for all general fluorescent lighting
CFL Magnetic Ballasts 2 – FT36W/2G11 RS 120 (4150P)
General characteristics
Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected
Electrical characteristics Supply Current Frequency
60 Hz
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 2.3 in (60 mm) 1.5 in (39 mm) 8.8 in (226 mm) 1.6 in (43 mm) 0.3 in (8 mm) 3.38 lbs Side 10 ft 18 AWG Length (± 1 in) 20 in (508 mm) 20 in (508 mm) 20 in (508 mm)
Specifications by lamp and wattage Lamp FT36W/4P
# of Lamps 2
Line Volts 120
System Watts 78
Safety and performance
Nom. Line Current 0.70 A
UL Type 1 Outdoor
UL Type HL
System Ballast Factor 0.96 UL Class P
Ballast Efficacy Factor 1.23
Power Factor % (>=) 93
Crest Factor (<=) 1.7
THD (<=) 20
Min. Starting Temp (°F/°C) 50 / 10
Programmed Start Dimming
Order information 10 Pack 87623
Wiring diagram – CFL 5 – see example on page 17-14 Case dimensions – Ref Drawing ST – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow
T8 Programmed Start
Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Ballasts
gelighting.com
UL Listed
T5 Electronic Programmed Start T12 Electronic & High Output
87625 – GEM2FT40RS120
• Magnetic compact fluorescent ballast construction for all general fluorescent lighting
CFL Magnetic Ballasts 2 – FT40W/2G11RS RS 120 (4152P)
Dimensions Magnetic – Rapid Start Rapid start Series 5% 105°F (41°C) 90°C (194°F) Normal A (20-24 decibels) Auto-restart, Thermally protected
Electrical characteristics Supply Current Frequency
60 Hz
Pallet Pack
DIY Pack
IP Pack
9.5 in (241 mm) 2.3 in (60 mm) 1.5 in (39 mm) 8.8 in (226 mm) 1.6 in (43 mm) 0.3 in (8 mm) 3.38 lbs Side 10 ft 18 AWG Length (± 1 in) 20 in (508 mm) 20 in (508 mm) 20 in (508 mm)
Sign
Order information 10 Pack 87625
Wiring diagram – CFL 5 – see example on page 17-14 Case dimensions – Ref Drawing ST – see page 17-16 Length (L) Width (W) Height (H) Mounting dimensions Bracket Length (BL) Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow
T12 Magnetic
General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info
Specifications by lamp and wattage Lamp FT40W/4P
# of Lamps 2
Line Volts 120
UL Type 1 Outdoor
UL Type HL
System Ballast Factor 1.00 UL Class P
Ballast Efficacy Factor 1.23
Power Factor % (>=) 98
Crest Factor (<=) 1.7
THD (<=) 20
Min. Starting Temp (°F/°C) 50 / 10
UL Listed
17-13
HID Electronic & Electromagnetic
See page E-1 for warranty information.
Nom. Line Current 0.68 A
Compact Fluorescent
Safety and performance
System Watts 81
Wiring Diagrams Compact Fluorescent Ballasts CFL 21
CFL 9
CFL 5
CFL 1-2
17-14
See page E-1 for warranty information.
Wiring Diagrams Compact Fluorescent Ballasts
Line
Black White
BALLAST
Blue Red
Line
Black White
BALLAST
T8 Instant Start
CFL IS2
CFL IS1
Ballasts
gelighting.com
Blue Blue Red
T8 Programmed Start Programmed Start Dimming
Line
Black White
CFL PS2 BALLAST
Blue Blue Blue Red
Line
Black White
BALLAST
T5 Electronic Programmed Start
CFL IS3
Blue Yellow Red
T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 17-15
HID Electronic & Electromagnetic
See page E-1 for warranty information.
Case Dimensions Compact Fluorescent Ballasts -A
8
2
13
ST
17-16
See page E-1 for warranty information.