Ballasts_T12

Page 1

Table of Contents T12 Electronic and High Output Ballasts

Ballasts

gelighting.com

T8 Instant Start

Understanding T12 Electronic Ballasts........................14-2

T8 Programmed Start

ProLineŽ T12 For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps........................................................ 14-3 For T12 4 ft – 8 ft Slimline Lamps............................................................................ 14-6 T12 High Output................................................................14-7 Wiring Diagrams...............................................................14-8 Case Dimensions..............................................................14-9

Programmed Start Dimming T5 Electronic Programmed Start T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 14-1

HID Electronic & Electromagnetic

See page E-1 for warranty information.


Understanding T12 Electronic Ballasts Electronic T12 GE multivolt and dedicated voltage ProLine® T12 high-performance ballasts are designed for replacement of magnetic T12 electronic ballasts during maintenance or retrofits. GE multivolt ProLine® T12 ballasts have the same wiring and mounting requirements as standard magnetic ballasts and provide up to 20% energy savings by simply replacing the ballast. The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot and 8 foot lamp ­electro­magnetic ballasts that operate T12 lamps and do not meet federal ballast efficiency requirements. GE ProLine® T12 electronic ballasts meet the DOE minimum ballast efficiency requirements and also allow facility managers to reduce ballast maintenance inventories by consolidating the number of ballasts needed. GE ProLine® T12 ballasts operate both energysaving and standard wattage lamps and are also multi-voltage (120-277V). With 2 ballasts, the multi-voltage ProLine® T12 can consolidate over 40 different magnetic ballasts. Performance Features • GE240RSMVN and GE240RS120 comply with FCC for residential use • Low-profile and lightweight housing ­simplifies installation and reduces ­transportation costs (GE240 = 1.3 lbs. lighter than magnetic; GE260 = 5.3 lbs. lighter than magnetic)

•P arallel operation — if one lamp fails, others remain lit • Significantly quieter than magnetic • High-frequency operation virtually ­eliminates lamp flickering typical in T12 electromagnetic systems • Five-year limited ballast warranty

Electromagnetic T12 • Complete line of ballasts for 2-to-8 foot lamps, circleline and high-output lamps • 100% thermally protected • High-grade lamination steel assures lowest wattage loss • UL, CSA and/or cUL approved • 888-GEBALLAST on every ballast • Two-year limited ballast warranty

Color-Coded Ballast and Outer Box Labels 120V – Yellow 277V – Red Packaging • Standard 10 packs • IP Packs – individually packed with ­instructions • DIY – shrink-wrapped and tray-packed with instructions

GE Ballast LFL magnetic nomenclature

G E M - 2 GE Ballast M = Electromagnetic Ballast GEH = HID Maximum ­number of lamps supported by this ballast: 1, 2, 3, 4

14-2

3 2 - H O - R S - 1 2 0 - D I Y Lamp Watts (Primary Lamp) T8 = 32 – 4 foot, 59 – 8 foot T12 = 40 – 4 foot, 60 – 8 foot T12 Electronic = 40 – 2-4 foot, 2 pin 60 – 4-8 foot, 1 pin 96 – 4-8 foot HO, 2 pin T12 Magnetic = 40 – 2-4 foot, 2 pin 96 – 4-8 foot, 2 pin

IS = Instant Start, default if not shown RS = Rapid Start PH = Preheat PT= Preheat/Trigger H = Hybrid D50 = Dimming (min level) = High Output HO VHO = Very High Output

120V – Yellow 277V – Red 220V – Green 240V – Orange 347 – Gray

Pack Type IP = Individual corrugated box per ballast 84T = Pallet bulk pack (84=840, 42=420 ballasts) DIY = Shrinkwrap ballast in tray pack DIY72 = Shrinkwrap ballast in pallet pack (Qty) No extension = 10 pack

See page E-1 for warranty information.


ProLine T12 T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps 74472 – GE240RS-MV-N (replaces 24107) ProLine® T12 Multivolt 120V – 277V 2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine® T12

Dimensions

General characteristics

70°C (158°F) Normal Active A (20-24 decibels) Metal Auto-restart, Thermally protected

Electrical characteristics Supply Current Frequency

60 Hz

Order information Std. pack 74472

Pallet Pack

DIY Pack 74473 (replaces 24773)

IP Pack

9.5 in (241 mm) 1.3 in (33 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 1.06 lbs Side 18 ft 18 AWG Length (± 1 in.) 48.0 in (1219 mm) 33.0 in (838 mm) 33.0 in (838 mm) 25.0 in (635 mm) 25.0 in (635 mm)

Specifications by lamp and wattage Lamp

F40T10

F34T12

F30T12/WM

F20T12

Safety and performance

System Watts 74 73 48 48 75 72 42 42 63 62 41 41 50 50 30 30 60 58 37 37 46 45 28 29

Nom. Line Current 0.67 A 0.30 A 0.41 A 0.19 A 0.63 A 0.27 A 0.35 A 0.17 A 0.56 A 0.26 A 0.35 A 0.17 A 0.42 A 0.20 A 0.26 A 0.13 A 0.31 A 0.22 A 0.31 A 0.16 A 0.39 A 0.18 A 0.24 A 0.13 A

UL Type 1 Outdoor

UL Type HL

System Ballast Factor 0.89 0.89

Ballast Efficacy Factor 1.20 1.22

0.88 0.88

1.17 1.22

0.87 0.87

1.38 1.40

0.95 0.95

1.90 1.90

0.95 0.95

1.58 1.64

1.00 1.00

2.17 2.22

UL Class P

NRCan

Power Factor% (>=) 99 97 99 95 99 94 99 88 99 96 99 94 99 91 99 82 99 96 99 94 99 94 99 92

FCC Part 18 Class B at 120 volts

cUL Listed

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD% (<=) 6 10 7 10 7 16 10 16 7 10 8 11 9 18 12 27 7 10 8 11 8 11 9 17

Min. Starting Temp (°F/°C) 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10 50.0/10

T12 Electronic & High Output

F30T12

Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277

T5 Electronic Programmed Start

F40T12

# of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1

Programmed Start Dimming

Wiring diagram – LFL PS2 – see example on page 14-8 Case dimensions – Ref Drawing B1 – see page 14-9 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote mounting distance to lamp Remote Mounting Wire Gauge Lead lengths Yellow Blue Red Black White

Electronic – Programmed/ Rapid Start Rapid start Parallel 10%

T8 Programmed Start

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Enclosure Type Additional Info

T8 Instant Start

• High-performance electronic ballast for all general fluorescent applications • Multi-voltage technology handles voltage from 120 to 277V • Light weight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage

Ballasts

gelighting.com ®

UL Listed RoHS compliant

T12 Magnetic Sign Compact Fluorescent 14-3

HID Electronic & Electromagnetic

See page E-1 for warranty information.


ProLine® T12 T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps 97498 – GE240RS120

• High-performance electronic ballast for all general fluorescent applications • Light weight, low-profile housing

ProLine® T12 120V 2 – F40 or F34T12 Rapid Start 120V “N” BF ProLine® T12

General characteristics

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Electronic – Programmed / Rapid Start Rapid start Series 10% 221°F (105°C) 70°C (158°F) Normal Passive A (20-24 decibels) Auto-restart, Thermally protected

Wiring diagram – LFL PS2 – see example on page 14-8 Case dimensions – Ref Drawing B1 – see page 14-9 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths White and Black Blue and Red Yellow Yellow

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

Order information Std. pack 97498

Pallet Pack

DIY Pack 97499

IP Pack

9.5 in (241 mm) 1.3 in (33 mm) 1.0 in (25 mm) 8.9 in (226 mm) 0.9 in (22 mm) 0.3 in (8 mm) 1.38 lbs Side 18 ft 18 AWG Length (± 1 in) 25 in (635 mm) 33 in (838 mm) 48 in (1219 mm) 36 in (914 mm)

Specifications by lamp and wattage Lamp F25T12 FT36W/4P F34T12 F30T12 F12T9 F8T9 F16T9

# of Lamps 2 2 2 2 2 2 1 1 1

Line Volts 120 120 120 120 120 120 120 120 120

System Watts 73 70 63 62 59 59

Safety and performance

CSA

Nom. Line Current 0.62 A 0.60 A 0.54 A 0.53 A 0.50 A 0.50 A

UL Type 1 Outdoor

System Ballast Factor 1.10 0.58 0.85 0.85 0.92 0.53

ANSI – 62.41

UL Type HL

Ballast Efficacy 1.50 0.82 1.34 1.37 1.55 0.89

Power Factor % (>=) 1 0.98 98 96 0.92 0.95

FCC Part 18 Class B at 120 volts

UL Class P

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7

ANSI – C82.11

THD (<=) 20 20 20 25 25 0.53

UL Listed

Min. Starting Temp (°F/°C) 32/0 32/0 32/0 32/0 32/0 32/0 32/0 32/0 NRCan

75672 – GE140RS120 ProLine® T12 120V 1 - F40 or F34T12 Rapid Start Electronic 120V “N” BF ProLine® T12

General characteristics

Dimensions

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Electronic – Programmed/ Rapid Start Rapid start Parallel 10% 105°F (41°C) 75°C (167°F) Normal Active A (20-24 decibels) End-of-Life Protection (EOL), Thermally protected

Wiring diagram – LFL 2 – see example on page 14-8 Case dimensions – Ref Drawing 29 – see page 14-9 Length (L) 6.46 in (164 mm) Width (W) 1.37 in (35 mm) Height (H) 1.0 in (25 mm) Mounting dimensions Mount Length (M) 6.0 in (152 mm) Mount Width (X or F) 1.37 in (35 mm) Mount Slots (MS) Weight Exit Type Side Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths* Length (± 1 in) Blue and Red 25 in (635 mm) White and Black 15 in (381 mm) * See gelighting.com for wire lengths. Different for 10 pg vs. DIY pack.

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

Order information Std. pack 75672

Pallet Pack

DIY Pack 72110

IP Pack

Specifications by lamp and wattage Lamp F40T12/40W F40T12/25W F34T12/34W F30T12/30W

# of Lamps 1 1 1 1

Line Volts 120 120 120 120

Safety and performance

14-4

System Watts 36 36 30 28

Nom. Line Current 0.53 A 0.53 A 0.45 A 0.41 A

Meets FCC Part 18 (Class B) Consumer Limits

System Ballast Factor 0.88 1.33 0.88 0.93 cUL Listed

Ballast Efficacy Factor 2.44 3.69 2.93 3.32

UL Listed

Power Factor % (>=) 57 57 55 58

Crest Factor (<=) 1.58 1.54 1.50 1.51

THD (<=) 150 150 150 150

Min. Starting Temp (°F/°C) 0 / -18 0 / -18 0 / -18 0 / -18

ANSI 62.41

See page E-1 for warranty information.


ProLine T12 T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12, F40T10 Lamps 24109 – GE340RS-MV-N ProLine® T12 Multivolt 120V – 277V 3 or 2 – F40 or F34T12 Rapid Start 120 to 277 ProLine® T12

General characteristics

Dimensions Electronic – Programmed / Rapid Start Rapid start Parallel 10% 105°F (41°C) 70°C (158°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

Order information Std. pack 24109

Pallet Pack

DIY Pack 24774

IP Pack

9.5 in (241 mm) 2.3 in (60 mm) 1.5 in (39 mm) 8.9 in (226 mm) 1.6 in (40 mm) 0.3 in (8 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in) 33 in (838 mm) 33 in (838 mm) 25 in (635 mm) 48 in (1219 mm)

Specifications by lamp and wattage Lamp

UL Type 1 Outdoor

UL Type HL

System Ballast Factor 0.89 0.89

Ballast Efficacy Factor 0.78 0.80

0.87 0.87

0.90 0.92

FCC – CLASS A Non-Consumer

UL Class P

Power Factor % (>=) 99 97 99 96 99 97 99 96 99 96 99 95 99 97 95 99

cUL Listed

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD (<=) 5 11 6 12 5 12 6 13 6 12 7 13 5 12 13 6

Min. Starting Temp (°F/°C) 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10 50 / 10

T12 Electronic & High Output

Safety and performance

Nom. Line Current 0.98 A 0.43 A 0.74 A 0.33 A 90.00 A 0.39 A 0.67 A 0.30 A 0.81 A 0.36 A 0.60 A 0.27 A 0.75 A 0.33 A 0.25 A 0.55 A

T5 Electronic Programmed Start

# of Lamps Line Volts System Watts 3 120 114 3 277 111 2 120 86 F40T12 2 277 85 3 120 107 3 277 105 2 120 80 F40T10 2 277 79 3 120 96 3 277 94 2 120 71 F34T12 2 277 70 3 120 90 3 277 87 2 277 67 F30T12 2 120 66 Other compatible lamps: F30T12/WM, F40T12/WMP

Programmed Start Dimming

Wiring diagram – LFL PS3 – see example on page 14-8 Case dimensions – Ref Drawing ST – see page 14-9 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Blue and Red Red/White White and Black Yellow

T8 Programmed Start

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

T8 Instant Start

• High-performance electronic ballasts for all general fluorescent applications • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage

Ballasts

gelighting.com ®

UL Listed

T12 Magnetic Sign Compact Fluorescent 14-5

HID Electronic & Electromagnetic

See page E-1 for warranty information.


ProLine® T12 T12 Electronic and High Output Ballasts For T12 4 ft – 8 ft Slimline Lamps 74474 – GE-260IS-MV-N (replaces 24108)

• High-performance electronic ballasts for all general fluorescent applications • Instant start electronic ballast for long lamp starting cycles and low initial cost • Multi-voltage technology handles voltage from 120 to 277V • Lightweight, low-profile housing • Parallel lamp operation means system maintenance is easier to manage

ProLine® T12 Multivolt 120V – 277V 2 or 1 – F96T12 Instant Start 120 to 277

Dimensions

General characteristics Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Enclosure Type Additional Info

Wiring diagram – LFL 14 – see example on page 14-8 Case dimensions – Ref Drawing B1 – see page 14-9 Length (L) Width (W) Height (H) Mounting dimensions Mount Length (M) Mount Width (X or F) Mount Slots (MS) Weight Exit Type Remote Mounting Distance to Lamp Remote Mounting Wire Gauge Lead lengths Black White Red Blue

Electronic - Multivolt Instant Start Instant start Parallel 10 % 70 °C (158 °F) Normal Active A (20-24 decibels) Metal Auto-restart, Thermally protected

Electrical characteristics

Supply Current Frequency

50Hz/60 Hz

Order information 10 Pack 74474

Pallet Pack

DIY Pack 74475 (replaces 24776)

IP Pack

9.5 in (241 mm) 1.7 in (43 mm) 1.18 in (30 mm) 8.9 in (226 mm) 1.18 in (30 mm) 0.3 in (8 mm) 2.40 lbs Side 18 ft 18 AWG Length (± 1 in.) 25.0 in (635 mm) 25.0 in (635 mm) 59.0 in (1499 mm) 67.0 in (1702 mm)

Specifications by lamp and wattage Lamp

F96T12/WMP

F96T12/WM

F96T12

F84T12

F72T12

F64T12

F60T12

F48T12

# of Lamps 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1

Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277 120 277

Safety and performance

14-6

System Watts 107 106 68 68 112 110 72 71 141 138 90 89 125 123 80 79 107 106 69 69 97 96 63 63 92 91 60 60 73 73 49 48

Nom. Line Current 0.94 A 0.40 A 0.60 A 0.27 A 0.98 A 0.42 A 0.63 A 0.28 A 1.24 A 0.53 A 0.79 A 0.34 A 1.10 A 0.47 A 0.70 A 0.30 A 0.94 A 0.40 A 0.60 A 0.27 A 0.86 A 0.37 A 0.55 A 0.25 A 0.81 A 0.35 A 0.53 A 0.28 A 0.65 A 0.29 A 0.43 A 0.20 A

UL Type 1 Outdoor

NRCan

System Ballast Factor 0.88 0.88 1.00 1.00 0.90 0.90 1.00 1.00 0.90 0.90 1.02 1.02 0.90 0.90 1.04 1.04 0.90 0.90 1.04 1.04 0.90 0.90 1.08 1.08 0.90 0.90 1.08 1.08 0.90 0.90 1.10 1.10 UL Type HL

Ballast Efficacy Factor 0.82 0.83 1.47 1.47 0.80 0.82 1.39 1.41 0.64 0.65 1.13 1.15 0.72 0.73 1.30 1.32 0.84 0.85 1.51 1.51 0.93 0.94 1.71 1.71 0.98 0.99 1.80 1.80 1.23 1.23 2.24 2.29

FCC – CLASS A Non-Consumer

Power Factor% (>=) 99 96 99 95 99 97 99 95 99 98 99 96 99 97 99 96 99 97 99 95 99 97 99 95 99 96 99 94 99 95 99 89 UL Class P

cUL Listed

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 UL Listed

THD% (<=) 8 10 10 12 8 10 10 12 8 10 10 12 8 10 10 12 8 10 10 12 8 10 10 12 8 10 10 12 8 10 10 12

Min. Starting Temp (°F/°C) 60.0/16 60.0/16 60.0/16 60.0/16 60.0/16 60.0/16 60.0/16 60.0/16 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18 0.0/-18

RoHS compliant

See page E-1 for warranty information.


T12 High Output T12 Electronic and High Output Ballasts

T8 Instant Start

75671 – GE296HO-MV-N T12 High Output ProLine® T12 Multivolt 120V – 277V 2 or 1 – F96T12 HO RS 120 to 277 Multivolt ProLine®

General characteristics

Dimensions Electronic – Programmed/ Rapid Start Rapid start Series 10% 105°F (41°C) 75°C (167°F) Normal Active A (20-24 decibels) Auto-restart, Thermally protected

Wiring diagram – LFL PS2 – see example on page 14-8 Case dimensions – Ref Drawing SL – see page 14-9 Length (L) 11.75 in (299 mm) Width (W) 2.15 in (55 mm) Height (H) 1.61 in (41 mm) Mounting dimensions Mount Length (M) 11.0 in (279 mm) Mount Width (X or F) 2.15 in (55 mm) Mount Slots (MS) Weight Exit Type Side Remote Mounting Distance to Lamp* Remote Mounting Wire Gauge * See gelighting.com for wire lengths. Different for 10 pg vs. DIY pack.

Electrical characteristics Supply Current Frequency

50 Hz/60 Hz

Std. pack 75671

Pallet Pack

DIY Pack 72109

IP Pack

Specifications by lamp and wattage Lamp F96T12/HO/ WM

F70T8 F60T12/HO F48T12/HO

Line Volts 120 277 120 277 120 277 120 277 120 277 120 277 120 277

Safety and performance

System Watts 164 164 196 196 104 104 154 154 120 119 132 132 112 113 cUL Listed

Nom. Line Current 1.38 A 0.62 A 1.65 A 0.73 A 0.88 A 0.42 A 1.30 A 0.57 A 1.17 A 0.52 A 0.50 A 0.50 A 0.95 A 0.43 A UL Listed

System Ballast Factor 0.90 0.90 0.90 0.90 0.92 0.92 0.90 0.90 0.90 0.90 0.90 0.90 0.90 0.90

Ballast Efficacy Factor 0.55 0.55 0.46 0.46 0.88 0.88 0.58 0.58 0.75 0.76 0.68 0.68 0.80 0.80

Power Factor % (>=) 99 99 99 97 99 95 99 96 99 97 96 96 99 95

Crest Factor (<=) 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7

THD% (<=) 10 10 10 10 15 15 10 10 10 10 10 10 15 15

Min. Starting Temp (°F/°C) 60.0/16 60.0/16 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29 -20.0/-29

T5 Electronic Programmed Start

F96T12/HO F72T12/HO

# of Lamps 2 2 2 2 1 1 2 2 2 2 2 2 2 2

Programmed Start Dimming

Order information

T8 Programmed Start

Ballast Type Starting Method Lamp Wiring Line Voltage Regulation (+/-) Ambient Temperature (MAX) Case Temperature (MAX) Ballast Factor Power Factor Correction Sound Rating Additional Info

Ballasts

gelighting.com

FCC Part 18 (Class A) Non Consumer

T12 Electronic & High Output T12 Magnetic Sign Compact Fluorescent 14-7

HID Electronic & Electromagnetic

See page E-1 for warranty information.


Wiring Diagrams T12 Electronic and High Output Ballasts LFL PS2

LFL PS3

LFL 14

LFL 2

14-8

See page E-1 for warranty information.


Case Dimensions T12 Electronic and High Output Ballasts

T8 Programmed Start

SL

T12 Electronic & High Output T12 Magnetic

Sign

Compact Fluorescent

HID Electronic & Electromagnetic

14-9

See page E-1 for warranty information.

T5 Electronic Programmed Start

D10, 15, 29

Programmed Start Dimming

B1

T8 Instant Start

ST

Ballasts

gelighting.com


T12 Electronic and High Output Ballasts Notes

14-10

See page E-1 for warranty information.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.