ssssss

Page 1

PRODUCT INFORMATION AND SPECIFICATION GUIDE

e GE Sports Lighting Systems

1


INDEX Ultra✭SportTM Floodlight System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Ultra✭Sport Floodlight Customer List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Ultra✭Sport Floodlight Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Ultra✭Sport Floodlight Structural Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 UL TS — Outdoor/Indoor Ultra✭Sport Floodlight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ULTS UL TK — Outdoor Ultra✭Sport Floodlight with Instant Hot Restart . . . . . . . . . . . . . . . . . . . . . 8 ULTK UL TE — Outdoor/Indoor Ultra✭Sport Floodlight with Integral Encapsulated Ballast . . . . . . . . 9 ULTE UL TO — Outdoor/Ultra✭Sport Floodlight with Remote Ballast . . . . . . . . . . . . . . . . . . . . . . . 10 ULTO UL TT — Outdoor Ultra✭Sport Floodlight with Remote Ballast and Instant Hot Restart . . . . . 11 ULTT UL TI — Indoor Ultra✭Sport Floodlight with Remote Ballast . . . . . . . . . . . . . . . . . . . . . . . . . . 12 ULTI UL TR — Indoor Ultra✭Sport Floodlight with Remote ballast and Instant Hot Restart . . . . . . . 13 ULTR Ultra✭Sport Floodlight Quick Reference Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ultra✭Sport Floodlight Electrical Data 2000-Watt Metal Halide Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1500-Watt Metal Halide Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 1000-Watt Metal Halide Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Ultra✭Sport Floodlight Lamp Characteristics 2000-Watt Metal Halide Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1500-Watt Metal Halide Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1000-Watt Metal Halide Lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Ultra✭Sport Floodlight Hot Restart Start Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Ultra✭Sport Floodlight Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Ultra✭Sport Floodlight Dimensions (Diagram A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Remote Ballast Housing Dimensions (Diagram B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Ultra✭Sport Floodlight Spacing Criterion Horizontal Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Vertical Spacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Ultra✭Sport Floodlight Photometric Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Ultra✭Sport Floodlight Accessories Safety Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Cross Arm Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

2


Ultra✭SportTM Floodlight System The GE Ultra✭SportTM floodlight is proven lamp, optical and ballast technology from various lighting applications packaged together for the first time in a state of the art sports lighting design. The end result is unmatched light output and efficiency with excellent visibility and color rendering for players, spectators and television broadcasting. Ultra✭Sport floodlights also offer outstanding control of unwanted glare and spill-light pollution and include affordable optional features like Instant Hot Restart and System 2TM Bi-Level lighting controls. When you look at all the features the Ultra✭Sport floodlight has to offer, you will agree the Ultra✭Sport floodlight is light years ahead of the competition. The Ultra✭Sport floodlight system significantly reduces the number of fixtures required to provide the same required light output and uniformity ratios. As a result you get: • Lower installation costs • Lower structural costs • Lower maintenance costs • Less energy consumption ✭ Sport Suggested applications for the Ultra✭ floodlight system include: • IESNA Class III to major stadia where premium quality lighting and excellent glare control are required. • Medium to large indoor arenas. • Large stadia and arenas where television recording and broadcasting will be common, and excellent color rendering and high vertical plane illumination are required. • Sports fields and arenas where optional Instant Hot Restart is desired in case of momentary power interruption or large line dips. This feature can be critical when television recording and broadcasting is taking place and revenues may be at risk if there is a short-duration power loss that could cause an 8 to 12-minute fixture blackout. • Facilities requiring instant off/on capability for dramatic theatrical lighting. • Other general floodlighting applications where premium lighting is required from a high-wattage metal halide light source.

Ultra✭Sport Floodlight Customer List The Ultra✭Sport floodlight sports lighting system has been installed in the following applications. United States Professional Anaheim Stadium, Anaheim, CA – Baseball Bowie Field, Bowie, MD – Baseball Coors Field, Denver, CO – Baseball Kaffman Stadium, Kansas City, KS – Baseball Seattle Mariners, Seattle, WA – Baseball 89er’s Ballpark, Oklahoma City, OK – AAA Baseball BiLo Center, Greenville, SC – Hockey/Basketball Bradley Arena, Milwaukee, WI – Hockey/Basketball Gund Arena, Cleveland, OH – Hockey/Basketball Sam Houston, Track Houston, TX – Horse Racing Jaguar’s Stadium, Jacksonville, FL – Football Sun Devil’s, Phoenix, AZ – Football Memorial Park, Las Vegas, NV – Softball

International Gabba Stadium, Brisbane, Australia – Cricket Karnataka Stadium, Bangalore, India – Cricket Bukit Jalil, Kuala Lumpur – Men’s Field Hockey Bukit Jalil, Kuala Lumpur – Women’s Field Hockey Montreal Forum, Montreal, Quebec – Hockey/Basketball Abu Dhabi Race Track, Abu Dhabi, UAE – Horse Racing Aguilera Stadium, Santa Cruz, Bolivia – Soccer Al Hali, Abu Dhabi, UAE – Soccer Estádio Arequipa, Arequipa, Peru – Soccer Estádio do Maracanã, Rio de Janeiro, Brazil – Soccer Estádio do Mineirão, Belo Horizonte, Brazil – Soccer Estádio do Paranaense, Curitiba, Brazil – Soccer Maldonado Stadium, Maldonado, Uruguay – Soccer Police Academy, Abu Dhabi, UAE – Soccer Salmiya Club, Kuwait – Soccer Venecia International, Doha, Qatar – Soccer Manila Golf Course, Manila, Philippines – Golf

College New Mexico State University, Las Cruces, NM – Basketball University Of Virginia, Charlottesville, VA – Field Hockey Auburn University, Auburn, AL – Football Hofstra University, New York, NY – Football Michigan State University Ease Lansing, MI – Football Notre Dame, South Bend, IN – Football M. Tennessee State University, Nashville, TN – Football Princeton University Princeton, NJ – Football University Of Nebraska, Lincoln, NE – Football Rutgers University, New Brunswick, NJ – Soccer Skidmore College, Saratoga Springs, NY – Soccer Syracuse University, Syracuse, NY – Soccer University Of Maryland, College Park, MD – Soccer University Of Virginia, Charlottesville, VA – Soccer

High School Ottowa Hills Ottowa, OH – Tennis Hoover High School, Birmingham, AL – Baseball Rodeo Park High School, Tucson, AZ – Baseball East Henderson High School, Hendersonville, NC – Football Coronado High School, San Diego, CA – Football/Track West Henderson High School, Hendersonville, NC – Football

3


Ultra✭Sport Floodlight Features Luminaire Construction — The Ultra✭Sport floodlight’s optical reflectors and electrical components are enclosed and protected in integral, but thermally isolated, heavy-duty aluminum housings. The floodlight includes a permanent degree marker on both sides of the pivot point. A heavy-duty steel trunnion painted with a zinc rich epoxy powder finish for corrosion resistance can be mounted on either the top or bottom of the floodlight. Main Power Train Housing — The main housing is made of lightweight non-corrosive high pressure die-cast aluminum and is integral to the entire system. The main housing design isolates the upper optical ring from the lower electrical compartment for controlled thermal transfer. The lower compartment contains all electrical components including the optional hot restart and System 2 Bi-Level components, in a compact low-wind-load design. Unlike other sports lighting fixtures that offer hot restart, the Ultra✭Sport floodlight does not require any external add-on modules or transformers that attach to the standard unit or protrude into the reflector and reduce photometric performance. All hot restart components mount inside the standard housing, so both the standard and hot restart units have the same external appearance and performance. Rear Reflector Housing — The Rear/ Primary reflector is housed in a non-corrosive high pressure die-cast aluminum cover hinged to the main housing ring and held shut by four corrosion-resistant fasteners. High temperature gaskets completely seal the rear reflector housing to the main housing. Front Reflector Housing — The 20-inch (508mm) Front/Secondary aluminum reflector is enclosed in a heavy-duty spun aluminum casing. The front tempered door glass is 1/8inch (3.2mm) thick and is permanently sealed and gasketed to the casing. A high temperature gasket seals the front optical to the housing.

4

Rear Access Relamping and Fixed Aiming — The Ultra✭Sport floodlight’s rear reflector cover serves as an access door to the optical for relamping and maintenance without any adjustment to the aiming of the floodlight. The cover hinges open to 90° for easy access. For safety, a primary power disconnect circuit removes power to the lamp when the rear access door is opened. Optical Design — A two-piece reflector configuration features a Rear/Primary reflector and a Front/Secondary reflector. The Rear/Primary reflector is made of press molded glass featuring a highly reflective dichroic coating for a mirror like finish and 95% visible light reflectivity. The Front/Secondary reflector is spun from high quality aluminum and has a GE-patented ALGLAS® finish. This new lamp/reflector configuration produces a more efficient and effective oval light distribution with very tight vertical light control to minimize wasted light and to maximize light on the playing field. Photometric Performance — Traditional sports lighting systems use metal halide lamps with large bulb jackets and mogul base sockets located in the axial center-line of the optical. This lamp design impedes optical efficiency by producing inefficient symmetrical light distributions with too much light in the upper beam. Some upper beam light is lost in the sky and grandstands or, in the worst case, can be the source of light trespass and glare. The Ultra✭Sport floodlight, on the other hand, utilizes an advanced double-ended metal halide lamp without a bulb jacket and a new reflector design. The elimination of the outer bulb jacket allows placement of the lamp arc into the focal point of the shallow parabolic reflector forms needed to build high center beam candlepower which provides the highest beam efficiency possible with wide beam distributions. This new lamp/reflector configuration produces a more efficient, oval light distribution with very tight vertical light control to minimize wasted light and maximize light on the playing field.


Glare/Spill Light Control — The Ultra✭Sport floodlight’s precise optical design limits the amount of vertical spill and light pollution without the use of external visor/ louver assemblies that increase wind loading and structural costs. Optional internal cutoff skirts are available to provide direct cutoff of the arc tube at 15 degrees above the center aiming point for optimum glare control without the high losses normally associated with external glare reducing devices. Advanced Metal Halide Lamp — The Ultra✭Sport floodlight takes advantage of metal halide lamp technology, proven by decades of use in all types of lighting applications. The Ultra✭Sport floodlight uses an advanced generation of lamps specifically designed for use in sports lighting. Offered in a choice of 2000, 1500 or 1000 watts, these white light sources feature a double-ended design without an outer jacket, and provide an average rated life of 3000, 6000 and 10,000 hours, respectively. A standard mogul base 1500-watt metal halide lamp has an average life of 3000 hours. These advanced lamps also provide excellent color rendering with a 4000 degree Kelvin color temperature. They are designed for a horizontal orientation plus or minus 4 degrees, and have no tilt factor. Hydro★Guard Filtered Optics — The entire optical is sealed, so that all thermal air transfer moves through an advanced filtering system with particle trapping, chemical absorbing, and moisture controlling properties—critical for optimum optical performance. Ballast System — All Ultra✭Sport floodlights feature a compact GE ballast system in which the ballast is directly mounted to the aluminum housing with a thermal wedge for optimum heat transfer. GE 2000, 1500 and 1000-watt auto-regulator circuits are designed to start and stabilize their respective double ended metal halide lamps. Every ballast undergoes a 2500-volt RMS “High Pot” and a 10Kv “Til” test in accordance with ANSI C82.4, C82.6 and C92.1 specifications. The ballast circuits are also designed to sustain a nominal lamp over a line voltage dip of 50% for up to

four seconds when operating at nominal line voltage according to ANSI specification C82.6. The ballast circuit will reliably start and stabilize a nominal lamp in ambient temperatures down to -20°C. Refer to individual product descriptions for operating ambient temperatures. Electrical access is achieved from the rear of the fixture without any adjustment to the aiming required. The rear housing cover is held in place by four captive corrosion-resistant cad-polymer coated screws. For safety reasons, electrical access is not permitted on fixtures with the hot restart feature and the rear housing cover is held in place by four tamper-proof corrosion-resistant cad-polymer screws. Instant Hot Restart — Ultra✭Sport floodlights can be ordered with a new optional instant hot restart feature. After a momentary power interruption or line voltage dip which causes the light to extinguish, the hot restart pulse will restart the lamp within two seconds of power reapplication. Unlike other sports lighting fixtures that offer hot restart, the Ultra✭Sport floodlight does not require any external add on modules, or transformers that attach to the standard unit or protrude into the reflector, to reduce photometric performance. All hot restart components mount inside the standard housing, so both the standard and hot restart fixtures have the same external appearance and performance. System 3 Bi-Level Controls — This option is offered with 2000-watt and 1500-watt floodlights. A 24-volt AC signal (supplied by the customer) switches the floodlight from high wattage operation to low wattage operation. The 2000 watt switches to 1500 watt for low wattage operation for both 60 Hz and 50 Hz. The 1500 watt switches to 1000 watt for low wattage operation at 60 Hz and 900 watt at 50 Hz. NOTE: Luminaires with the System 3 BiLevel controls must be operated at full power for 15 minutes before switching to low power. Failure to do this could result in short lamp life. For more details on System 3 Bi-Level controls please consult the GE Technical Bulletin OLP-2687.

5


Broken Glass Shutdown Circuit — Metal halide light sources produce ultraviolet (UV) radiation. If a person is directly exposed, this radiation can cause discomfort and sometimes permanent eye damage. Normally UV radiation is absorbed in the lamp’ s outer jacket. Unjacketed lamps rely on a luminaire’s optical lens to absorb the UV. If the lens of a fixture that uses an unjacketed lamp is broken, the escaping ultraviolet radiation can create a

potential health risk to players and spectators. The Ultra✭Sport floodlight is the first sports lighting fixture to feature a Broken Glass Shutdown Circuit to eliminate this risk. The system continuously senses the integrity of the front door lens. In the unlikely event that the lens is broken, the system automatically shuts off the power to the lamp. A Broken Glass Shutdown Circuit is a standard feature on all Ultra✭Sport floodlights.

Ultra✭Sport Floodlight Structural Data

6

Mounting — The standard Ultra✭Sport floodlight comes with a heavy-duty steel mounting trunnion finished with a zinc-rich epoxy powder paint for superior corrosion resistance. The trunnion can be either top or bottom mounted, is precision balanced for accurate aiming and is capable of withstanding wind forces equal to 125 mph with a 1.3 gust factor without misalignment of the floodlight.

Aiming — To aim, simply align the aiming sight located on the rear optical door with the aiming indicator on the edge of the optical and the target. Once these three points are aligned, tighten the trunnion bolts. Because all access to maintain the Ultra✭Sport floodlight is from the rear, the aiming never needs to be disturbed to relamp or perform ballast maintenance.

Finish — The standard Ultra✭Sport floodlight comes with an electrostatically applied TGIC charcoal gray polyester powder paint finish to the housing of the floodlight. This process consists of two separate paint coatings. The first coat is a modified acrylic applied by the electrocoat process to a thickness of approximately one mil. This coat acts as a primer and covers all surfaces inside and outside of the castings. The second coat is the TGIC polyester powder coat which is electrostatically applied to a minimum thickness of approximately 1.5 mils. Both coats are thermoset coatings which, by definition, means that when cured with heat, they will cross-link and result in a heat-resistant and chemically-resistant finish that will not melt when reexposed to expected operating temperatures. Polyester powder finishes are known for their tenacity in bonding to all kinds of surfaces as well as their resistance to chemical and physical abuse. Contact factory for other possible decorator colors.

Wind Loading/EPA — The maximum effective projected area (EPA) per floodlight is 3.1 sq. ft. (0.29 sq. M). Vibration — The Ultra✭Sport floodlight has passed a Sustained Vibration Endurance Test and a High Loading Vibration Test. The tests were conducted in accordance with GE standard No. 06.326.001. The endurance portion of the test is to simulate an infinite number of cycles at a force of 1 g. The high loading vibration test is a 4 g, 5000 cycle test to address shock loads and other miscellaneous forces that occur during handling, shipping and in service. Classification — The Ultra✭Sport floodlight has been given an Ingress Protection rating of IP55.


ULTS—Outdoor/Indoor Ultra✭Sport Floodlight General Description — The ULTS Ultra✭Sport floodlight is the standard floodlight and comes complete with a prewired integral ballast. The floodlight housing also contains all other electrical components. For dimensions of the floodlight see Diagram A on page 17. Ballast Description — The following ballasts are available for this floodlight: Wattage 2000

Voltage 208, 220, 240, 277, 347, 380, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 2000 220, 230, 240 1500 220, 230, 240 1000 220, 230, 240, 380, 400, 415

Hertz Ambient UL/CUL Listed UL Listed 60 25°C (277V, 347V IS CUL) UL Listed 60 25°C (120V, 277V, 347V IS CUL) UL Listed 60 40°C (120V, 277V, 347V IS CUL) 50 25°C NO 50 25°C NO 50

25°C

NO

Weight — Floodlight = 75.0 lbs (34.02 kg) Option Description — F = Fusing . The fuses are located inside the floodlight housing and can be accessed by removing the ballast cover of the unit. This option can be used in conjunction with any of the other options. P = Prewired with 6-ft #14/3 cable. Different lengths and gauges are available at customer request. This option can be used in conjunction with any of the other options. Bi-Level — This is a “Ballast Type” choice in our GE Ordering Number Logic, and is offered for outdoor use with 2000-watt and 1500-watt floodlights. A 15-volt AC signal (supplied by the customer) switches the floodlight from high wattage operation to low wattage operation. The 2000 watt switches to 1500 watt for low wattage operation for both 60 Hz and 50 Hz The 1500 watt switches to 1000 watt for low wattage operation at 60 Hz and 900 watt at 50 Hz. Bi-level is ordered by placing a “B” in the ballast type field of the ordering number matrix. This option can be used in conjunction with any of the other options.

7


ULTK—Outdoor Ultra✭Sport with Instant Hot Restart General Description — The ULTK Ultra✭Sport floodlight comes complete with a prewired integral ballast. The floodlight housing also contains all other electrical components including the instant hot restart components. For dimensions of the floodlight see Diagram A on page 17. The lower housing is fastened with tamper-proof screws due to high voltage hot restart components and contains no field servicable parts. Instant Hot Restart — After a momentary power interruption or line voltage dip which causes the light to extinguish, the 34 Kv hot restart pulse will restart the lamp within two seconds of power reapplication. Refer to table on page 16 for hot restart times. Ballast Description — The following ballasts are available for this floodlight: Wattage 2000

Voltage 208, 220, 240, 277, 347, 380, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 2000, 1500, None*

Hertz Ambient UL/CUL Approval UL Listed 60 25°C (277V, 347V IS CUL) UL Listed 60 25°C (120V, 277V, 347V IS CUL) 50 N/A N/A

*50Hz is not available with ULTK. Please refer to ULTT or ULTR.

Weight — Floodlight = 80.0 lbs (36.28 kg) Ordering Notes — This unit must be ordered with the “P” option or other cable length. Fusing and Bi-Level are not available with this floodlight. Option Description — P = Prewired with 6-ft #14/3 cable. This option must be ordered with all ULTK’s. Different lengths and gauges are available at customer request.

8


ULTE—Outdoor/Indoor Ultra✭Sport with Integral Encapsulated Ballast General Description — The ULTE Ultra✭Sport floodlight comes complete with a prewired integral ballast that is encapsulated with a polyresin silica compound to reduce harmonic noise pollution. The floodlight housing also contains all other electrical components including the instant hot restart components. For dimensions of the floodlight see Diagram A on page 17. Ballast Description — The following ballasts are available for this floodlight: Wattage 1500, 1000 1500, 1000 1500, 1000

Voltage 120, 208, 240, 277 220, 347, 480 NONE*

Hertz 60 60 50

Ambient 40°C 40°C N/A

UL/CUL Listed UL Listed NO N/A

*50Hz is not available with ULTE.

Weight — Floodlight = 90.0 lbs (40.82 kg) Ordering Notes — Bi-Level is not available with this floodlight. Option Description — F = Fusing. The fuses are located inside the floodlight housing and can be accessed by removing the ballast cover of the unit. This option can be used in conjunction with the “P” option but not with the Hot Restart option. P = Prewired with 6-ft #14/3 cable. Different lengths and gauges are available at customer request. This option can be used in conjunction with any of the other options and must be used with the “Hot Restart” option. Hot Restart — This option is available with either the 1500-watt or the 1000-watt luminaire. This option is not UL listed. Hot Restart is ordered by placing a “K” in the ballast type field of the catalog number matrix. The “P” option must also be ordered with Hot Restart. This option cannot be used in conjunction with the “F” option. See page 16 for hot restart times.

9


ULTO—Outdoor Ultra✭Sport with Remote Ballast General Description — The ULTO Ultra✭Sport floodlight is provided with a vertical surface mounted remote ballast housing which contains the ballast core and coil. The remote ballast housing is encapsulated with a polyresin silica compound to reduce harmonic noise pollution. The floodlight housing contains all other electrical compo-

nents. For dimensions of the floodlight see Diagram A on page 17. For dimensions of the remote ballast housing see Diagram B on page 17. Ballast Description — The following ballasts are available for this floodlight: Wattage 2000

Voltage 208, 220, 240, 277, 347, 380, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 2000 220, 230, 240, 380 1500 220, 230, 240 1000 220, 230, 240, 380, 400, 415

Hertz Ambient UL/CUL Listed 60 25°C NO 60

25°C

50 50 50

25°C 25°C 25°C

UL Listed (120V, 277V, 347V IS CUL) NO NO NO

Weight — Floodlight = 55.0 lbs (24.95 kg) Remote Ballast Housing = 68.0 lbs (30.84 kg)

10

Option Description — F = Fusing. The fuses are located inside the floodlight housing and can be accessed by removing the ballast cover of the unit. This option can be used in conjunction with any of the other options. P = Prewired with 6-ft #14/3 cable. Different lengths and gauges are available at customer request. Note: This is for the power cable that

is connected to the floodlight. A separate cable connects the floodlight to the remote ballast housing; cable length must be specified by the customer. This option can be used in conjunction with any of the other options. Bi-Level — This option is offered with 2000watt and 1500-watt floodlights. A 15-volt AC signal (supplied by the customer) switches the floodlight from high wattage operation to low wattage operation. The 2000 watt switches to 1500 watt for low wattage operation for both 60 Hz and 50 Hz. The 1500 watt switches to 1000 watt for low wattage operation at 60 Hz and 900 watt at 50 Hz. Bi-level is ordered by placing a “B” in the ballast type field of the ordering number matrix. This option can be used in conjunction with any of the other options.


ULTT — Outdoor Ultra✭Sport with Remote Ballast and Instant Hot Restart General Description — The ULTT Ultra✭Sport floodlight is provided with a vertical surface mounted remote ballast housing which contains the ballast core and coil. The remote ballast housing is encapsulated with a polyresin silica compound to reduce harmonic noise pollution. The floodlight housing contains all other electrical compo-

nents. For dimensions of the floodlight see Diagram A on page 17. For dimensions of the remote ballast housing see Diagram B on page 17. The lower housing is fastened with tamper proof screws due to high voltage hot restart components and contains no field servicable parts. Instant Hot Restart — After a momentary power interruption or line voltage dip which causes the light to extinguish, the 34 Kv hot restart pulse will restart the lamp within two seconds of power reapplication. Refer to table on page 16 for hot restart times. Ballast Description — The following ballasts are available for this floodlight: Wattage 2000

Voltage 208, 220, 240, 277, 347, 380, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 2000 220, 230, 240, 380 1500 220, 230, 240 1000 220, 230, 240, 380, 400, 415

Weight — Floodlight = 60.0 lbs (27.22 kg) Remote Ballast Housing = 68.0 lbs (30.84 kg) Ordering Notes — This unit must be ordered with the “P” option or other cable length. Fusing is not available with this floodlight. Bi-Level is not available with this floodlight. Option Description — P = Prewired with 6-ft #14/3 cable. This option must be ordered with all ULTT’s. Different lengths and gauges are available at customer request. Note: This is for the power cable that is connected to the floodlight. A separate cable connects the floodlight to the remote ballast housing; the cable length must be specified by the customer.

Hertz Ambient UL/CUL Listed 60 25°C NO 60

25°C

50 50 50

25°C 25°C 25°C

UL Listed (277V, 347V IS CUL) NO NO NO

11


ULTI — Indoor Ultra✭Sport with Remote Ballast General Description — The ULTI Ultra✭Sport floodlight is provided with a vertical surface mounted remote ballast housing which contains the ballast core and coil. The remote ballast housing is encapsulated with a polyresin silica compound to reduce harmonic noise pollution. The floodlight housing contains all other electrical compo-

nents. For dimensions of the floodlight see Diagram A on page 17. For dimensions of the remote ballast housing see Diagram B on page 17. Ballast Description — The following ballasts are available for this floodlight: Wattage 2000

Voltage 208, 220, 240, 277, 347, 380, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 2000 220, 230, 240, 380 1500 220, 230, 240 1000 220, 230, 240, 380, 400, 415

Hertz Ambient UL/CUL Listed 60 40°C NO 60

55°C

50 50 50

40°C 40°C 40°C

UL Listed (120V, 277V, 347V IS CUL) NO NO NO

Weight — Floodlight = 55.0 lbs (24.95 kg) Remote Ballast Housing = 68.0 lbs (30.84 kg)

12

Option Description — F = Fusing. The fuses are located inside the floodlight housing and can be accessed by removing the ballast cover of the unit. This option can be used in conjunction with any of the other options. P = Prewired with 6-ft #14/3 cable. Different lengths and gauges are available at customer request. Note: This is for the power cable that

is connected to the floodlight. A separate cable connects the floodlight to the remote ballast housing; the cable length must be specified by the customer. This option can be used in conjunction with any of the other options.


ULTR — Indoor Ultra✭Sport with Remote Ballast and Instant Hot Restart General Description — The ULTR Ultra✭Sport floodlight is provided with a vertical surface mounted remote ballast housing which contains the ballast core and coil. The remote ballast housing is encapsulated with a polyresin silica compound to reduce harmonic noise pollution. The floodlight housing contains all other electrical compo-

nents. For dimensions of the floodlight see Diagram A on page 17. For dimensions of the remote ballast housing see Diagram B on page 17. The lower housing is fastened with tamper proof screws due to high voltage hot restart components and contains no field servicable parts. Instant Hot Restart — After a momentary power interruption or line voltage dip which causes the light to extinguish, the 34 Kv hot restart pulse will restart the lamp within two seconds of power reapplication. Refer to table on page 16 for hot restart times. Ballast Description — The following ballasts are available for this floodlight: Wattage 2000

Voltage 208, 220, 240, 277, 347, 380, 480 1500, 1000 120, 208, 220, 240, 277, 347, 480 2000 220, 230, 240, 380 1500 220, 230, 240 1000 220, 230, 240, 380, 400, 415

Weight — Floodlight = 60.0 lbs (27.22 kg) Remote ballast housing = 68.0 lbs (30.84 kg) Ordering Notes — This unit must be ordered with the “P” option or other cable length. Fusing is not available with this floodlight. Bi-Level is not available with this floodlight. Option Description — P = Prewired with 6-ft #14/3 cable. This option must be ordered with all ULTR’s. Different lengths and gauges are available at customer request. Note: This is for the power cable that is connected to the floodlight. A separate cable connects the floodlight to the remote ballast housing; the cable length must be specified by the customer.

UL/CUL Hertz Ambient Listed 60

40°C

60 50 50

55°C 40°C 40°C

NO UL Listed (120V, 277V, 347V IS CUL) NO NO

50

40°C

NO

13


Ultra✭Sport Floodlight Quick Reference Chart Ultra✭ Sport Watts

Volts

Hertz

Ambient UL

Hot Restart

Bi-Level

Fusing

Customer Cable

ULTS 2000

208, 220, 240, 277, 347, 380, 480

60

25°C

YES

NO

OPTION

OPTION

OPTION

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

25°C

YES

NO

OPTION

OPTION

OPTION

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

40°C

YES

NO

OPTION

OPTION

OPTION

2000 OR 1500 220, 230, 240

50

25°C

NO

NO

OPTION

OPTION

OPTION

1000

220, 230, 240, 380, 400, 415

50

25°C

NO

NO

OPTION

OPTION

OPTION

208, 220, 240, 277, 347, 380, 480

60

25°C

YES

YES

NO

NO

REQUIRED

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

25°C

YES

YES

NO

NO

REQUIRED

60

40°C

YES

OPTION NO

OPTION

OPTION*

60

40°C

NO

OPTION NO

OPTION

OPTION*

208, 220, 240, 277, 347, 380, 480

60

25°C

NO

NO

OPTION

OPTION

OPTION

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

25°C

YES

NO

OPTION

OPTION

OPTION

2000

220, 230, 240, 380

50

25°C

NO

NO

OPTION

OPTION

OPTION

1500

220, 230, 240

50

25°C

NO

NO

OPTION

OPTION

OPTION

1000

220, 230, 240, 380, 400, 415

50

25°C

NO

NO

OPTION

OPTION

OPTION

208, 220, 240, 277, 347, 380, 480

60

25°C

NO

YES

NO

NO

REQUIRED

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

25°C

YES

YES

NO

NO

REQUIRED

2000

220, 230, 240, 380

50

25°C

NO

YES

NO

NO

REQUIRED

1500

220, 230, 240

50

25°C

NO

YES

NO

NO

REQUIRED

1000

220, 230, 240, 380, 400, 415

50

25°C

NO

YES

NO

NO

REQUIRED

2000

208, 220, 240, 277, 347, 380, 480

60

40°C

NO

NO

OPTION

OPTION

OPTION

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

55°C

YES

NO

OPTION

OPTION

OPTION

2000

220, 230, 240, 380

50

40°C

NO

NO

OPTION

OPTION

OPTION

1500

220, 230, 240

50

40°C

NO

NO

OPTION

OPTION

OPTION

1000

220, 230, 240, 380, 400, 415

50

40°C

NO

NO

OPTION

OPTION

OPTION

208, 220, 240, 277, 347, 380, 480

60

40°C

NO

YES

NO

NO

REQUIRED

1500 OR 1000 120, 208, 220, 240, 277, 347, 480

60

55°C

YES

YES

NO

NO

REQUIRED

2000

220, 230, 240, 380

50

40°C

NO

YES

NO

NO

REQUIRED

1500

220, 230, 240

50

40°C

NO

YES

NO

NO

REQUIRED

1000

220, 230, 240, 380, 400, 415

50

40°C

NO

YES

NO

NO

REQUIRED

ULTK 2000

ULTE 1500 OR 1000 120, 208, 240, 277 1500 OR 1000 220, 347, 480 ULTO 2000

ULTT 2000

ULTI

ULTR 2000

*Customer cable is required with the Instant Hot Restart option.

14


Ultra✭Sport Ballast Electrical Data Ballast System — All Ultra✭Sport floodlights feature a compact GE ballast system in which the ballast is directly mounted to the aluminum housing with a thermal wedge for optimum heat transfer. GE 2000, 1500 and 1000-watt auto-regulator circuits are designed to start and stabilize their respective double ended metal halide lamps. Every ballast undergoes a 2500-volt RMS “High Pot” and a 10 Kv “Til” test in accordance with ANSI C82.4, C82.6 and C92.1 specifications. The ballast circuits are also designed to sustain a nominal lamp over a line voltage dip of 50% for up to four seconds when operating at nominal line voltage according to ANSI specification C82.6. The ballast circuit will reliably start and stabilize a nominal lamp in ambient temperatures down to -20°C.

2000-Watt Metal Halide Ballasts Line 208 V 220 V 240 V 277 V 347 V 380 V 480 V 220 V 230 V 240 V 380 V

Line Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 50 Hz 50 Hz 50 Hz 50 Hz

Line Starting Current 10.2 Amps 9.4 Amps 8.6 Amps 7.7 Amps 6.1 Amps 5.4 Amps 4.8 Amps 9.8 Amps 9.2 Amps 9.0 Amps 5.7 Amps

Line Operating Current 11.3 Amps 10.6 Amps 9.7 Amps 8.5 Amps 6.7 Amps 6.0 Amps 4.9 Amps 10.7 Amps 10.2 Amps 9.8 Amps 6.3 Amps

Line Watts 2166 2179 2162 2159 2156 2178 2157 2177 2198 2196 2167

1500-Watt Metal Halide Ballasts Line 120 V 208 V 220 V 240 V 277 V 347 V 480 V 220 V 230 V 240 V

Line Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 50 Hz 50 Hz 50 Hz

Line Starting Current 11.1 Amps 6.6 Amps 5.6 Amps 5.6 Amps 4.8 Amps 4.2 Amps 2.9 Amps 6.0 Amps 5.7 Amps 5.4 Amps

Line Operating Current 13.8 Amps 8.5 Amps 7.6 Amps 7.0 Amps 6.0 Amps 5.2 Amps 3.5 Amps 7.9 Amps 7.3 Amps 7.1 Amps

Line Watts 1691 1767 1661 1691 1671 1764 1677 1678 1635 1647

1000-Watt Metal Halide Ballasts Line 120 V 208 V 220 V 240 V 277 V 347 V 480 V 220 V 230 V 240 V 380 V 400 V 415 V

Line Frequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz

Line Starting Current 7.1 Amps 4.1 Amps 3.8 Amps 3.5 Amps 3.1 Amps 2.5 Amps 1.7 Amps 4.4 Amps 4.2 Amps 4.0 Amps 2.7 Amps 2.6 Amps 2.4 Amps

Line Operating Current 9.9 Amps 5.7 Amps 5.3 Amps 5.0 Amps 4.3 Amps 3.5 Amps 2.4 Amps 5.4 Amps 5.2 Amps 5.0 Amps 3.3 Amps 3.1 Amps 2.9 Amps

Line Watts 1134 1125 1081 1141 1139 1154 1068 1115 1108 1114 1145 1150 1128

15


Ultra✭Sport Lamp Characteristics Advanced Metal Halide Lamp — The Ultra✭Sport floodlight takes advantage of metal halide lamp technology, proven by decades of use in all types of lighting applications. The Ultra✭Sport floodlight uses an advanced generation of lamps specifically designed for use in sports lighting. Offered in a choice of 2000, 1500 or 1000 watts, these white light sources feature a double-ended design without an outer jacket, and provide an average rated life of 3000, 6000 and 10,000 hours, respectively. A standard mogul base 1500-watt metal halide lamp has an average life of 3000 hours. These advanced lamps also provide excellent color rendering with a 4000 degree Kelvin color temperature. They are designed for a horizontal orientation plus or minus 4 degrees, and have no tilt factor. 2000-Watt Metal Halide Lamp Catalog Number—GE Lighting . . . . . . . . . . . . . . . . . . MQI/2000/T9/40 Catalog Number—OSRAM Sylvania . . . . . . . . . . . . . . . . M2000T9/DE ANSI Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U134 Burning Position . . . . . . . . . . . . . . . . . . . . . . . . Horizontal ± 4 Degrees MOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.00 Inches (254mm) LCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.00 Inches (127mm) Arc Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 Inches (108mm) Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ceramic #8-10 Spade Lamp Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 ± 10 Volts Lamp Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.5 Amps Ignitor Pulse (Peak) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000-5000 Volts Pulse Width @ 3600 volts . . . . . . . . . . . . . . . . . . . . . . One Microsecond Minimum Pulse Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 Volts Initial Lumens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200,000 Mean Lumens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170,000 Average Rated Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3000 Hours Color Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 Kelvin CRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RA=65+ Hot Restart Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Lamp Seal Temperature . . . . . . . . . . . . . . . . . . . . Not to exceed 450°C Bulb Wall Temperature . . . . . . . . . . . . . . . . . . . . . Not to exceed 950°C

1500-Watt Metal Halide Lamp Catalog Number - GE Lighting . . . . . . . . . . . . . . . . . . . MQI/1500/T8/40 Catalog Number - OSRAM Sylvania . . . . . . . . . . . . . . . . M1500T8/DE ANSI Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U133 Burning Position . . . . . . . . . . . . . . . . . . . . . . . . Horizontal ± 4 Degrees MOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.00 Inches (254mm) LCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.00 Inches (127mm) Arc Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 Inches (108mm) Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ceramic #8-10 Spade Lamp Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 ± 10 Volts Lamp Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.3 Amps Ignitor Pulse (Peak) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000-5000 Volts Pulse Width @ 3600 volts . . . . . . . . . . . . . . . . . . . . . . One Microsecond Minimum Pulse Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 Volts 100 Hours . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100% 40% Rated Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85% Average Rated Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6000 Hours Color Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 Kelvin CRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RA=65+ Hot Restart Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Lamp Seal Temperature . . . . . . . . . . . . . . . . . . . . Not to exceed 450°C Bulb Wall Temperature . . . . . . . . . . . . . . . . . . . . . Not to exceed 950°C

1000-Watt Metal Halide Lamp Catalog Number - GE Lighting . . . . . . . . . . . . . . . . . . . MQI/1000/T7/40 Catalog Number - OSRAM Sylvania . . . . . . . . . . . . . . . . M1000T7/DE ANSI Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U133 Burning Position . . . . . . . . . . . . . . . . . . . . . . . . Horizontal ± 4 Degrees MOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.00 Inches (254mm) LCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.00 Inches (127mm) Arc Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 Inches (108mm) Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ceramic #8-10 Spade Lamp Volts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 ± 10 Volts Lamp Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2 Amps Ignitor Pulse (Peak) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000-5000 Volts Pulse Width @ 3600 volts . . . . . . . . . . . . . . . . . . . . . . One Microsecond Minimum Pulse Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 Volts 100 Hours . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100% 40% Rated Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85% Average Rated Life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6000 Hours Color Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 Kelvin CRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RA=65+ Hot Restart Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes Lamp Seal Temperature . . . . . . . . . . . . . . . . . . . . Not to exceed 450°C Bulb Wall Temperature . . . . . . . . . . . . . . . . . . . . . Not to exceed 950°C

Ultra✭Sport Hot Restrike Restart Times

16

LENGTH OF BLACKOUT 1500W METAL HALIDE LAMP

2000W METAL HALIDE LAMP

2 Second Power Loss

98% Light output instantly—10 Seconds to reach 100%

98% Light output instantly—10 Seconds to reach 100%

30 Second Power Loss 70% Light output instantly—45 Seconds to reach 100%

65% Light output instantly—60 Seconds to reach 100%

60 Second Power Loss 65% Light output instantly—55 Seconds to reach 100%

60% Light output instantly—90 Seconds to reach 100%

90 Second Power Loss 60% Light output instantly—60 Seconds to reach 100%

55% Light output instantly—120 Seconds to reach 100%

2 Minute Power Loss

27% Light output instantly—75 Seconds to reach 100%

50% Light output instantly—180 Seconds to reach 100%

3 Minute Power Loss

14% Light output instantly—80 Seconds to reach 100%

19% Light output instantly—195 Seconds to reach 100%

5 Minute Power Loss

3% Light output instantly—120 Seconds to reach 100%

7% Light output instantly—230 Seconds to reach 100%

10 Minute Power Loss

0.7% Light output instantly—240 Seconds to reach 100% 0.3% Light output instantly—285 Seconds to reach 100%


Ultra✭Sport Packaging The Ultra✭Sport floodlight is packaged in one of two ways. A single pack is used if less than four floodlights are ordered. If four or more floodlights are ordered then they will be packaged in a “Magnapack”. These are big, sturdy palletized containers that hold up to eight floodlights. A Magnapack can contain up to eight standard Ultra✭Sport floodlights or four Ultra✭Sport floodlights with remote ballast housings. The Magnapack consists of a corrugated container which is treated with a weather resistant coating. The corrugated container is fastened to a pallet which offers access from all four sides. This allows easy

access for lifting into storage racks of varying sizes. GE Magnapack Advantages — • Virtually eliminates freight damage • Simplifies handling • Reduces corrugated paper disposal • Cuts installation time • Less space is needed (increased cube utilization) • Provides 4-way fork truck access • Offers a reusable weather-resistant container • Available at no additional cost

Magnapack Dimensions Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55-1/2 inches (141 cm) Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 inches (112 cm) Depth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 inches (81 cm) Pallet thickness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 inches (7.6 cm) Standard fixture quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 complete units per Magnapack Remote ballast fixture quantity . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 complete units per Magnapack

Diagram A — Ultra✭Sport Dimensions

Diagram B — Remote Ballast Housing Dimensions

17


Ultra✭Sport Spacing Criterion Horizontal Spacing

Vertical Spacing

GE recommends that each floodlight be spaced 30 inches (762mm) apart for ease of aiming. See diagram below.

GE recommends that a clearance height of 32 inches (813mm) be left between the luminaires in order to facilitate ease of aiming and lamp replacement.

Ultra✭Sport Photometric Data Photometric Performance — Traditional sports lighting systems use metal halide lamps with large bulb jackets and mogul base sockets located in the axial centerline of the optical. This lamp design impedes optical efficiency by producing inefficient symmetrical light distributions with too much light in the upper beam. Some upper beam light is lost in the sky and grandstands, or in the worst case, can be the source of light trespass and glare. The Ultra✭Sport floodlight, on the other hand, utilizes an advanced double-ended metal halide lamp without a bulb jacket and with a new reflector design. The elimination of the outer bulb jacket allows placement of the lamp arc into the focal point of the shallow parabolic reflector forms needed to build high center-beam candlepower and provide the highest beam efficiency possible with widebeam distributions.

18

Wattage 1000 watt 1500 watt 2000 watt

Photometric Curve Number 35-xxxxxx S01 S02 M01 450423 450424 450426 179085 179086 179087 179085 179086 179087

M02 450426 179088 179088

Offered in a choice of 2000, 1500 or 1000 watts, these white light sources provide an average rated life of 3000, 6000 and 10,000 hours respectively. A two-piece reflector configuration is utilized featuring a rear/primary reflector and a front/secondary reflector. The rear/primary reflector is made of press-molded glass featuring a highly reflective dichroic coating for a mirror-like finish and 95% visible light reflectivity. The front/secondary reflector is spun from high quality aluminum and has a GE-patented ALGLAS finish. This new lamp/ reflector configuration produces a more efficient, oval light distribution with very tight vertical light control to minimize wasted light and maximize light on the playing field. The following four pages show photometric curves for the Ultra✭Sport floodlight. Please refer to the table below for specific curve numbers.

W01 450427 179089 179089

W02 450428 179090 179090

WW1 450682 179412 179412

WW2 450681 179413 179413


2,400 1200 00-45

-40 -35 -30 -25 -20 -15 -10 -5

0

5

DEGREES

VERTICAL DOTTED LINE

10 15

LOWER VERTICAL BEAM

25 30 35

40

45

HORIZONTAL SOLID LIN E

PHOTOMETRIC DATA 9,600

20

35-450424-00

CANDELA TRACES UPPER VERTICAL BEAM

8,400

LUMINOUS INTENSITY CANDELA

6,000

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

4,800 3,600 2,400 1200 00-45

-40 -35 -30 -25 -20 -15 -10 -5

0

5

DEGREES

VERTICAL DOTTED LINE

10

9,600

20

25 30 35

40

45

HORIZONTAL SOLID LIN E

PHOTOMETRIC DATA LOWER VERTICAL BEAM

15

CANDELA TRACES

35-450425-00 UPPER VERTICAL BEAM

8,400

LUMINOUS INTENSITY CANDELA

6,000

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

4,800 3,600 2,400 1200 00-45

-40 -35 -30 -25 -20 -15 -10 -5

0

5

DEGREES

VERTICAL DOTTED LINE

10 15

25 30 35

40

45

HORIZON TAL SOLID LINE

PHOTOMETRIC DATA 12,800 LOWER VERTICAL BEAM

20

35-450426-00

CANDELA TRACES UPPER VERTICAL BEAM

11,200

LUMINOUS INTENSITY CANDELA

8,000

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

6,400 4,800 3,200 1600 00

-27 -24 -21 -18 -15 -12 -9 VERTICAL DOTTED LINE

-6

-3

0

3

DEGREES

6

9

12

15 18 21

24

27

HORIZONTAL SOLID LIN E

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPE RATE D AT 1,000 LUM EN S. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATIN G DIVIDED BY 1,000. PER 1000 LAMP LUMENS

5

0

0.7

0.6

U

0.9

1.0

1.1

1.1

0.9

20

10.8

0.5

0.7

0.9

1.0

1.2

1.4

1.6

1.8

1.5

P P

15.7 22.7

0.5 0.6

0.9 1.0

1.2 1.4

1.4 1.7

1.7 2.1

1.9 2.5

2.3 3.2

2.8 4.6

3.0 5.5

R

30.0

0.6

1.2

1.6

2.0

2.5

3.1

4.1

6.3

8.6

B

36.2

0.7

1.2

1.7

2.2

2.8

3.6

4.9

7.3 11.8

41.8 45.8

0.7 0.7

1.3 1.2

1.7 1.6

2.2 2.0 %

E A

40.8

0.6

1.0

1.4

32.3

0.6

0.9

23.2 15.4

0.5 0.5

0.7 0.6

9.9

0.4

6.4 4.6 3.7 3.3

15

% LAMP LUMENS

10

0.7

0.8

12 9 5 4 7 10 11 12 13 13 14 14

E

2.9 3.9 2.7 3.6

5.4 8.1 15.6 5.2 8.8 20.0 " %

1.8

2.3

3.1

4.5

8.1 17.9

1.2

1.5

1.9

2.6

3.7

6.9 13.0

0.9 0.7

1.2 0.9

1.5 1.1

2.0 1.5

2.9 2.2

5.3 3.2

0.5

0.6

0.7

0.9

1.1

1.5

1.9

0.3

0.4

0.5

0.5

0.7

0.8

1.0

1.1

8.1 W 4.6 E 2.2 R 1.0 B

0.3 0.2

0.4 0.3

0.4 0.4

0.4 0.4

0.5 0.4

0.6 0.5

0.7 0.5

0.7 0.5

0.6 0.5

A

0.2

0.3

0.3

0.3

0.4

0.4

0.4

0.4

0.4

M

M L O

E

8.6 13.8 17.9 22.1 27.3 34.3 45.9 69.8 ****

18 16 14 12 10 8 6 4 2 0 0 -2 -4 -6 -8

-10 -12 -14 -16 -18

LUMENS SUMMATION OF VERTICAL ZONES 35.6 34.7 33.3 31.5 29.3 26.6 23.2 18.6 11.6

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION 45

HORIZONTAL ANGLES DEGREES

40

35

30

25

20

15

10

5

0

22 21

3.1 6.5

0.1 0.2

0.2 0.4

0.3 0.5

0.3 0.7

0.4 0.8

0.5 0.9

0.5 1.0

0.4 1.0

0.4 1.0

U

21

10.6

0.3

0.6

0.7

0.9

1.2

1.4

1.7

1.9

1.8

P

16.6

0.5

0.8

1.0

1.3

1.6

2.0

2.5

3.2

3.6

24.3

0.6

1.0

1.4

1.7

2.2

2.7

3.4

5.2

6.2

E R

31.2 37.0

0.6 0.7

1.2 1.3

1.6 1.8

2.1 2.3

2.6 2.9

3.3 3.8

4.3 5.1

6.5 9.0 7.4 11.7

B

42.4

0.7

1.3

1.8

2.3

3.0

4.0

5.6

8.4 15.3

A

45.5

0.7

1.2

1.6 2.1 %

2.8

3.7

5.2 8.8 19.4 " %

M

38.0 28.3

0.7 0.6

1.1 0.9

1.4 1.3

1.8 1.6

2.4 1.9

3.1 2.5

4.3 3.5

7.5 15.7 5.8 10.2

L O

20.6

0.6

0.9

1.1

1.3

1.5

1.9

2.7

4.3

6.4

W

14.2

0.6

0.8

0.9

1.0

1.2

1.5

2.0

2.7

3.5

E

10.0

0.5

0.7

0.8

0.9

1.0

1.2

1.5

1.8

1.8

7.7

0.5

0.6

0.7

0.8

0.8

0.9

1.1

1.2

1.1

R B

6.4 5.7

0.4 0.3

0.6 0.5

0.6 0.6

0.7 0.6

0.7 0.6

0.8 0.7

0.9 0.8

0.9 0.8

0.9 0.8

A

5.3

0.3

0.5

0.5

0.6

0.6

0.6

0.7

0.7

0.7

M

20 18 16 12 9 5 4 7 9 10 11 12 13 13 14

P

E

E

8.9 14.4 18.5 22.9 28.3 35.5 46.6 68.7 ****

18 16 14 12 10 8 6 4 2 0 0 -2 -4 -6 -8

-10 -12 -14 -16 -18

LUMENS SUMMATION OF VERTICAL ZONES 35.3 34.5 33.0 31.2 28.9 26.0 22.5 17.8 11.0

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION 45

HORIZONTAL ANGLES DEGREES

40

35

30

25

20

15

10

5

21 20

5.7 7.5

0.3 0.4

0.5 0.6

0.6 0.7

0.7 0.8

0.7 0.9

0.7 1.0

0.8 1.1

0.7 1.0

20 19 17

10.5 15.0 21.1

0.4 0.5 0.5

0.7 0.8 1.0

0.9 1.1 1.4

1.1 1.4 1.7

1.2 1.6 2.1

1.4 1.9 2.5

1.6 2.2 3.0

1.7 2.6 4.2

15 12 9 4

29.0 35.7 41.3 44.4

0.6 0.6 0.6 0.6

1.1 1.2 1.2 1.1

1.5 1.6 1.6 1.5

2.0 2.2 2.2 2.0

3.1 3.6 3.8 3.6

4.0 4.8 5.4 5.1

6.0 7.2 8.0 8.3 "

41.8 30.2

0.6 0.5

1.1 0.9

1.4 1.2

% 1.8 1.5

2.5 2.8 2.9 2.7 2.4 1.9

3.3 2.5

4.7 3.6

22.7 15.6 10.1

0.5 0.4 0.4

0.7 0.6 0.5

1.0 0.8 0.6

1.2 1.0 0.7

1.5 1.2 0.9

2.0 1.5 1.1

2.9 2.2 1.5

6.8 5.0 4.1 3.5

0.3 0.3 0.2 0.2

0.5 0.4 0.3 0.3

0.5 0.4 0.4 0.4

0.6 0.5 0.4 0.4

0.7 0.5 0.5 0.4

0.8 0.6 0.5 0.5

1.0 0.7 0.6 0.5

4 7 9 11 12 13 13 14 14

0

18 16 14

0.6 U 0.9 P 1.5 P

12 10 8

2.8 E 4.8 R 8.1 B 11.6 E 15.6 A 19.4 M

% 7.9 18.6 L 6.3 11.8 O 4.9 8.0 W 3.3 2.0 1.2 0.8 0.6 0.5

4.7 E 2.3 R 1.2 B 0.7 E 0.6 A 0.5 M

6 4 2 0 0 -2 -4

-6 -8 -10 -12 -14 -16 -18

8.0 13.6 17.7 22.2 27.3 34.4 45.8 67.1 ****

LUMENS SUMMATION OF VERTICAL ZONES 35.0 34.2 32.8 31.1 28.8 26.1 22.7 18.1 11.4

% LAMP LUMENS

General Electric ULTRA✭SPORT Floodlight

Reflector 35-450554-04, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 3x2 BEAM SPREAD . . . . VERT.=19° . . . . . . . HORIZ.=45° BEAM EFFICIENCY . . . . . . . 43% BEAM FLUX . . . . . 425 LUMENS MAX. CANDELA . . . . . . . . . 9399 TOTAL EFFICIENCY. . . . . . . . 82%

15

0.7

0.7

ISOCANDELA CURVE LUMEN DISTRIBUTION 27

HORIZONTAL ANGLES DEGREES

24

21

18

15

12

9

6

3

0

18

2.0

0.2

0.2

0.2

0.2

0.3

0.2

0.2

0.2

0.2

U

18

3.5

0.3

0.4

0.4

0.4

0.4

0.4

0.4

0.3

0.3

17

6.4

0.5

0.6

0.7

0.7

0.8

0.8

0.8

0.8

0.7

P P

11.7 18.0

0.8 1.0

0.9 1.2

1.0 1.3

1.1 1.5

1.3 1.8

1.5 2.2

1.6 2.7

1.7 3.0

1.7 3.3

R

25.1

1.3

1.5

1.7

1.9

2.3

2.9

3.7

4.5

5.3

B

31.9

1.4

1.7

1.9

2.3

2.8

3.4

4.5

6.1

7.8

37.9 41.5

1.5 1.3

1.7 1.6

2.0 1.9

2.5 2.3

3.0 2.8

3.8 3.6

4.9 4.9

7.4 11.1 8.1 15.0 " %

E A

32.7

1.1

1.4

1.6

1.9

2.4

3.1

4.3

6.8 10.2

25.1

1.0

1.1

1.3

1.6

2.0

2.7

3.6

5.1

6.8

18.0 12.5

0.8 0.7

0.9 0.8

1.0 0.8

1.3 1.0

1.6 1.2

2.1 1.5

2.7 1.8

3.3 2.1

8.4

0.6

0.6

0.7

0.8

0.9

1.0

1.2

1.3

6.0

0.5

0.5

0.6

0.6

0.7

0.7

0.8

0.8

4.3 W 2.6 E 1.3 R 0.7 B

4.8 4.6

0.5 0.4

0.5 0.4

0.5 0.5

0.5 0.5

0.6 0.5

0.6 0.5

0.6 0.6

0.6 0.6

0.6 0.6

A

4.4

0.4

0.4

0.4

0.5

0.5

0.5

0.5

0.5

0.6

M

17 15 14 11 8 4 3 6 8 9 10 10 11 11 12

14.4 16.3 18.7 21.7 25.7 31.7 39.8 53.2 73.0

E

M L O

E

18 16 14 12 10 8 6 4 2 0 0 -2 -4 -6 -8

VERTICAL ANGLES DEGREES

9,600

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAM P OPERATED AT 1,000 LUM EN S . IF THE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N R AT I N G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFF E R E N T LA M P L U M E N RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

20

0.7

0.6

General Electric ULTRA✭SPORT Floodlight

Reflector 35-430554-03, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x2 BEAM SPREAD . . . . VERT.=20° . . . . . . . HORIZ.=47° BEAM EFFICIENCY . . . . . . . 45% BEAM FLUX . . . . . 447 LUMENS MAX. CANDELA . . . . . . . . . 9129 TOTAL EFFICIENCY. . . . . . . 85%

25

0.7

0.4

VERTICAL ANGLES DEGREES

7,200

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPE RATE D AT 1,000 LUM EN S. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATIN G DIVIDED BY 1,000. PER 1000 LAMP LUMENS

30

0.6

7.5

General Electric ULTRA✭SPORT Floodlight

Reflector 35-430554-02, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x2 BEAM SPREAD . . . . VERT.=20° . . . . . . . HORIZ.=50° BEAM EFFICIENCY . . . . . . . 49% BEAM FLUX . . . . . 486 LUMENS MAX. CANDELA . . . . . . . . . 8440 TOTAL EFFICIENCY. . . . . . . 84%

35

0.5

21

VERTICAL ANGLES DEGREES

7,200

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPE RATE D AT 1,000 LUM EN S. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATIN G DIVIDED BY 1,000. PER 1000 LAMP LUMENS

40

0.3

19 18

% LAMP LUMENS

3,600

HORIZONTAL ANGLES DEGREES

5.6

LUMENS SUMMATION OF ONE SIDE ONLY

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

4,800

45 22

LUMENS SUMMATION OF ONE SIDE ONLY

LUMINOUS INTENSITY CANDELA

6,000

ISOCANDELA CURVE LUMEN DISTRIBUTION

VERTICAL ANGLES DEGREES

7,200

Reflector 35-430554-01, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x2 BEAM SPREAD . . . . VERT.=20° . . . . . . . HORIZ.=46° BEAM EFFICIENCY . . . . . . . 47% BEAM FLUX . . . . . 465 LUMENS MAX. CANDELA . . . . . . . . . 9234 TOTAL EFFICIENCY. . . . . . . . 86%

% LAMP LUMENS

8,400

General Electric ULTRA✭SPORT Floodlight

LUMENS SUMMAT

35-450423-00

CANDELA TRACES UPPER VERTICAL BEAM

% LAMP LUMENS

9,600

LOWER VERTICAL BEAM

LUMENS SUMMATION OF ONE SIDE ONLY

PHOTOMETRIC DATA

-10 -12 -14 -16 -18

LUMENS SUMMATION OF VERTICAL ZONES 29.4 28.0 26.4 24.5 22.3 19.8 16.6 12.6

7.3

% LAMP LUMENS

19


2,400 1,600 800 00-72

-64 -56 -48 -40 -32 -24 -16 -8

VERTICAL DOTTED LINE

0

8

DEGREES

16 24

40

48 56

64

72

HORIZONTAL SOLID LIN E

PHOTOMETRIC DATA 6400 LOWER VERTICAL BEAM

32

35-450428 -00

CANDELA TRACES

UPPER VERTICAL BEAM

4800 4000

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

3200 2400 1600 800 0

-72 -64 -56 -48 -40 -32 -24 -16 -8 VERTICAL DOTTED LINE

0

8

DEGREES

16

32

40

48 56

64

72

HORIZONTAL SOLID LIN E

PHOTOMETRIC DATA 6,400 LOWER VERTICAL BEAM

24

CANDELA TRACES

35-450682-00 UPPER VERTICAL BEAM

5,600

LUMINOUS INTENSITY CANDELA

4,000

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

3,200 2,400 1,600 800 00

-45 -40 -35 -30 -25 -20 -15 -10 -5 VERTICAL DOTTED LINE

0

5

DEGREES

PHOTOMETRIC DATA 3200

LOWER VERTICAL BEAM

10

15

20

25 30 35

40

45

HORIZONTAL SOLID LIN E

35-450681-00

CANDELA TRACES UPPER VERTICAL BEAM

2400 2000

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

1600 1200 800 400 0

-45 -40 -35 -30 -25 -20 -15 -10 -5 VERTICAL DOTTED LINE

20

0

5

DEGREES

10 15

20

25 30 35

40

45

HORIZONTAL SOLID LIN E

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAM P OPERATED AT 1,000 LUM E NS . IF T HE D ATA IS DESIRED FOR A DIFFERENT LA M P LU M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

16

8

0

0.8

1.0

1.1

1.2

U

0.0

0.3

0.7

0.9

1.1

1.3

1.5

P

7.8

0.0

0.0

0.0

0.5

1.0

1.2

1.4

1.7

1.9

10.8

0.0

0.0

0.0

0.6

1.3

1.7

2.0

2.4

2.8

P E

16.3

0.0

0.0

0.1

0.8

1.7

2.4

2.9

3.8

4.6

R

25.3 37.7

0.0 0.0

0.0 0.0

0.1 0.1

1.0 1.0

2.3 2.8

3.4 4.4

4.5 6.3

6.0 8.2 9.1 14.0

B

49.9

0.0

0.0

0.1

1.1

3.3

5.1

7.8 12.0 20.5

A

55.4

0.0

0.0

0.1

1.1 3.3 5.1 8.1 13.7 24.0 M " % "

51.5

0.0

0.0

0.1

1.1

2.9

4.3

6.8 11.7 24.6

37.9 24.0

0.0 0.0

0.0 0.0

0.1 0.1

1.1 0.9

2.2 1.7

3.3 2.4

4.9 3.4

15.1

0.0

0.0

0.1

0.8

1.3

1.7

2.3

8.7 17.7 O 5.9 9.7 W 3.7 5.3 E

10.1

0.0

0.0

0.1

0.6

1.0

1.2

1.6

2.4

3.2

R

7.5

0.0

0.0

0.0

0.5

0.8

1.0

1.3

1.7

2.2

6.0

0.0

0.0

0.0

0.3

0.7

0.9

1.1

1.4

1.6

B E

16

5.1

0.0

0.0

0.0

0.3

0.6

0.8

1.0

1.2

1.3

A

16

4.5

0.0 0.0

0.0 0.0

0.0 0.2 0.5 0.7 0.9 1.0 1.1 0.9 12.4 28.6 41.3 58.3 88.9 ****

M

20 18 17 14 11 6 5 9 11 13 14 15 15

E

L

27 24 21 18 15 12 9 6 3 0 0 -3 -6

-9 -12 -15 -18 -21 -24 -27

LUMENS SUMMATION OF VERTICAL ZONES 37.6 37.6 37.6 37.5 36.3 33.4 29.3 23.4 14.5

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION 72

HORIZONTAL ANGLES DEGREES 64

56

48

40

32

24

16

8

21

2.1

0.0

0.0

0.0

0.1

0.1

0.2

0.4

0.5

21 21

3.1 4.9

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.2

0.2 0.4

0.3 0.6

0.5 0.9

0.8 1.3

20

9.6

0.0

0.0

1.1

0.4

0.8

1.3

1.8

2.4

19 17

18.4 29.2

0.0 0.0

0.0 0.0

1.1 1.1

0.7 0.9

1.4 2.2

2.3 3.5

3.4 5.1

14

41.6

0.0

0.0

1.1

50.7 52.3

0.0 0.0

0.0 0.0

1.1 1.1

43.9 29.8

0.0 0.0

0.0 0.0

0.1 0.1

1.2 1.1

2.8 2.3

4.3 3.3

10 5 4 7 9

0

27

0.7 U 1.0 P

24 21 18

1.6 P 2.9 E 5.7 R

15

4.8 7.4 10.0 B 1.1 3.0 4.8 7.0 10.4 15.3 E 1.1 3.4 5.4 8.4 13.1 19.3 A 1.2 3.3 5.1 8.1 13.2 21.3 M % "

12 9 6 3 0 0

6.5 10.4 18.6 L 4.6 7.0 11.4 O 3.3 5.0 6.8 W 2.5 3.5 4.5 E

20.6

0.0

0.0

0.1

1.1

1.9

2.5

11 12

15.3 12.1

0.0 0.0

0.0 0.0

0.1 0.1

0.9 0.8

1.6 1.4

2.0 1.7

2.1

2.8

13

10.2

0.0

0.0

0.1

0.7

1.2

1.5

1.8

2.3

14 15

8.8 7.9

0.0 0.0

0.0 0.0

0.1 0.1

0.6 0.5

1.1 1.0

1.4 1.3

1.6 1.5

1.9 1.7

16

6.9

0.0

0.0

0.1

0.4

0.8

1.2

1.3

1.5

0.0

0.1

1.4 12.9 29.0 42.7 60.7 89.8 ****

-3 -6 -9

-12 -15

3.3 R 2.6 B 2.2 E

-18 -21 -24

1.9 A 1.6 M

-27

LUMENS SUMMATION OF VERTICAL ZONES 36.7 36.7 36.7 36.6 35.3 32.4 28.1 22.1 13.1

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES DEGREES

45

40

35

30

25

20

15

10

5

0

15

4.6

0.2

0.3

0.4

0.5

0.5

0.6

0.7

0.7

0.7

U

15

5.4

0.2

0.4

0.5

0.5

0.6

0.7

0.8

0.8

0.9

P

14

6.7

0.2

0.4

0.6

0.6

0.7

0.8

1.0

1.1

1.2

P

8.8

0.3

0.5

0.6

0.8

0.9

1.1

1.3

1.6

1.7

E

12.4

0.4

0.6

0.7

1.0

1.3

1.5

1.9

2.4

2.7

R

17.8

0.4

0.6

0.9

1.1

1.6

2.1

2.7

3.7

4.6

25.3

0.5

0.7

1.0

1.4

1.9

2.9

4.0

5.5

7.4

B E

33.9

0.5

0.8

1.1

1.5

2.2

3.8

5.6

7.8 10.9

A

37.5

0.5

0.7

1.0

1.4 2.1 3.5 5.7 % "

8.4 14.2

M

34.1

0.6

0.8

1.0

1.4

2.1

3.2

4.8

7.5 12.7

L

30.3

0.6

1.0

1.3

1.7

2.3

3.1

4.3

6.4

9.5

O

27.0

0.7

1.1

1.4

1.9

2.4

3.1

4.1

5.4

24.4 23.9

0.6 0.5

1.2 1.2

1.6 1.7

2.1 2.2

2.5 2.7

3.0 3.2

3.7 3.8

4.5 4.2

6.9 W 5.1 E

23.3

0.4

1.0

1.6

2.2

2.7

3.2

3.8

21.4

0.3

0.8

1.5

2.1

2.6

3.1

20

17.8

0.2

0.6

1.3

1.9

2.3

21

11.2

0.1

0.5

1.1

1.6

1.7

14 13 11 10 7 4 3 6 9 12 14 16 18

4.5

R

4.1

4.2

B

3.5

3.7

3.8

E

2.7

2.9

3.0

2.9

A

1.7

1.6

1.5

1.4

M

7.3 13.2 19.4 25.8 33.2 43.2 56.2 72.3 95.3

27 24 21 18 15 12 9 6 3 0 0 -3 -6 -9

-12 -15 -18 -21 -24 -27

LUMENS SUMMATION OF VERTICAL ZONES 36.6 35.9 34.5 32.6 30.0 26.7 22.4 16.8

9.5

% LAMP LUMENS

General Electric ULTRA ✭SPORT Floodlight

Reflector 35-430554-06, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x4 BEAM SPREAD . . . . VERT.=48° . . . . . . . HORIZ.=69° BEAM EFFICIENCY . . . . . . . 67% BEAM FLUX . . . . . 674 LUMENS MAX. CANDELA . . . . . . . . . 2570 TOTAL EFFICIENCY. . . . . . . . 81%

24

0.6

0.0

ISOCANDELA CURVE LUMEN DISTRIBUTION 45

HORIZONTAL ANGLES DEGREES

40

35

30

25

20

15

10

5

0 U P

45 40

13

0.5

0.0

0.0

0.0

0.0

0.1

0.1

0.1

0.1

0.1

13 13

0.7 1.3

0.0 0.0

0.0 0.1

0.0 0.1

0.1 0.1

0.1 0.1

0.1 0.2

0.1 0.2

0.1 0.2

0.1 0.2

2.4 4.3

0.1 0.1

0.1 0.2

0.1 0.2

0.2 0.3

0.3 0.4

0.3 0.6

0.4 0.7

0.4 0.9

0.5 1.0

8.3 19.0

0.1 0.5

0.2 0.6

0.4 0.9

0.6 1.3

0.8 1.7

1.1 2.3

1.4 3.0

1.7 4.0

1.9 4.8

38.0 55.7

0.7 0.9

1.1 1.3

1.5 1.9

2.1 2.6 "

3.1 4.4 6.0 8.3 10.8 3.9 6.2 9.2 12.7 16.9 %

M

5 0

L

0 -5

13 13 12 11 9 6 5 10 14 18 22 24 25 26 26

P E R B E A

50.3

1.0

1.5

1.9

2.6

3.8

5.5

7.7 10.9 15.3

45.7 43.6

1.2 1.2

1.9 2.2

2.5 3.1

3.4 4.0

4.3 4.9

5.6 5.9

7.1 6.8

44.3 36.9

0.9 0.6

2.1 1.6

3.2 2.8

4.2 3.8

5.2 4.6

6.2 5.3

7.1 5.9

9.0 10.7 O 7.6 7.9 W 7.7 7.7 E 6.2 6.1 R

19.5

0.4

1.0

2.0

2.7

2.9

2.9

2.7

2.4

2.4

11.3 8.1

0.3 0.2

0.6 0.3

1.0 0.5

1.5 0.8

1.6 1.0

1.6 1.2

1.6 1.3

1.6 1.4

1.6 1.4

4.9

0.1 0.1 0.2 0.3 0.5 0.7 0.8 1.0 1.1 8.4 14.8 22.5 30.8 39.4 49.9 62.2 76.2 90.6

LUMENS SUMMATION OF VERTICAL ZONES 39.5 38.6 37.2 34.9 31.8 27.9 22.9 16.7

% LAMP LUMENS

9.1

B E A M

35 30 25 20 15 10

VERTICAL ANGLES DEGREES

LUMINOUS INTENSITY CANDELA

2800

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPE RATE D AT 1,000 LUM EN S. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATIN G DIVIDED BY 1,000. PER 1000 LAMP LUMENS

32

0.2

0.0

General Electric ULTRA✭SPORT Floodlight

Reflector 35-430554-05, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x3 BEAM SPREAD . . . . VERT.=41° . . . . . . . HORIZ.=52° BEAM EFFICIENCY . . . . . . . 60% BEAM FLUX . . . . . 604 LUMENS MAX. CANDELA . . . . . . . . . 3875 TOTAL EFFICIENCY . . . . . . .84%

40

0.0

6.0

VERTICAL ANGLES DEGREES

4,800

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPE RATE D AT 1,000 LUM EN S. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATIN G DIVIDED BY 1,000. PER 1000 LAMP LUMENS

48

0.0

21

General Electric ULTRA✭SPORT Floodlight

Reflector 35-430554-06, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 5x3 BEAM SPREAD . . . . VERT.=35° . . . . . . . HORIZ.=82° BEAM EFFICIENCY . . . . . . . 60% BEAM FLUX . . . . . 600 LUMENS MAX. CANDELA . . . . . . . . . 3410 TOTAL EFFICIENCY. . . . . . . 81%

56

0.0

VERTICAL ANGLES DEGREES

LUMINOUS INTENSITY CANDELA

5600

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPE RATE D AT 1,000 LUM EN S. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N RAT IN G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: D IFFE R E N T L A M P L UM E N RATIN G DIVIDED BY 1,000. PER 1000 LAMP LUMENS

64

4.9

20

% LAMP LUMENS

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

3,200

HORIZONTAL ANGLES DEGREES

72 21

LUMENS SUMMATION OF ONE SIDE ONLY

LUMINOUS INTENSITY CANDELA

4,000

ISOCANDELA CURVE LUMEN DISTRIBUTION

VERTICAL ANGLES DEGREES

4,800

Reflector 35-430554-05, Refractor Clear Flat Glass Socket Position Fixed LAMP 1000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 5x3 BEAM SPREAD . . . . VERT.=30° . . . . . . . HORIZ.=77° BEAM EFFICIENCY . . . . . . . 58% BEAM FLUX . . . . . 580 LUMENS MAX. CANDELA . . . . . . . . . 4365 TOTAL EFFICIENCY. . . . . . . 84%

% LAMP LUMENS

5,600

General Electric ULTRA✭SPORT Floodlight

LUMENS SUMMAT

UPPER VERTICAL BEAM

% LAMP LUMENS

35-450427-00

LUMENS SUMMATION OF ONE SIDE ONLY

CANDELA TRACES

% LAMP LUMENS

6,400

LOWER VERTICAL BEAM

LUMENS SUMMATION OF ONE SIDE ONLY

PHOTOMETRIC DATA

-10 -15

-20 -25 -30 -35 -40 -45


35-179085-00

CANDELA TRACES

UPPER VERTICAL BEAM

6,000

5,000

Reflector 35-430554-01, Refractor Clear Flat Glass Socket Position Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x2 BEAM SPREAD . . . . VERT.=21° . . . . . . . HORIZ.=61° BEAM EFFICIENCY . . . . . . . 53% BEAM FLUX . . . . . 532 LUMENS MAX. CANDELA . . . . . . . . . 6682 BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

4,000

3,000

2,000

1,000

00

-45 -40 -35 -30 -25 -20 -15 -10 -5 VERTICAL–DOTTED LINE

0

5

10

15

DEGREES

20

25

30

35

40

45

HORIZONTAL–SOLID LINE

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES–DEGREES 18 18 17 16 15 14 11 8 5 5 9 12 14 15 16 17 17 17

45 5.0 6.3 8.4 11.5

40 0.2 0.3 0.3 0.4

35 0.4 0.5 0.5 0.6

30 0.5 0.6 0.7 0.8

25 0.6 0.7 0.8 1.0

20 0.6 0.8 1.0 1.3

15 0.7 0.9 1.1 1.5

16.1 22.1 29.6 38.0 46.4

0.4 0.5 0.5 0.6 0.6

0.7 0.8 0.9 1.0 1.1 400

47.1 39.8

0.6 0.5

1.1 1.0

31.1 21.2 13.2 8.0 5.8 4.7 3.9

0.5 0.8 1.2 1.7 2.3 3.1 4.6 0.4 0.7 1.0 1.4 1.8 2.4 3.3 0.4 0.6 0.8 1.0 1.3 1.7 2.2 0.4 0.5 0.6 0.8 0.9 1.1 1.3 1.3 0.3 0.5 0.5 0.6 0.7 0.7 0.8 0.8 0.3 0.4 0.5 0.5 0.6 0.6 0.6 0.6 0.3 0.4 0.4 0.5 0.5 0.5 0.5 0.5 7.4 12.5 17.0 22.2 28.3 36.5 49.9 73.9

1.0 1.3 1.6 1.1 1.5 1.9 1.3 1.7 2.3 1.4 1.9 2.6 1.5 2.0 2.8 700 1000

2.0 2.5 3.0 3.5 3.8

1.5 1.4

3.8 3.6

2.1 2.0

2.8 2.6

10 0.7 0.9 1.3 1.8

50 0.6 0.9 1.3 2.0

0 0.6 0.8 1.2 2.0 3.5

U P P E R

2.6 3.1 3.5 4.6 5.6 4.4 6.6 8.8 5.1 8.4 13.6 5.5 10.0 19.0 2000 4000

B E A M

9.9 19.7 9.1 14.3 7.0 9.8 4.5 5.7 2.6 2.6

L O W E R

1.2 0.8 0.6 0.5 ***

B E A M

5.7 5.3

18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18

VERTICAL ANGLES–DEGREES

LUMINOUS INTENSITY–CANDELA

7,000

General Electric ULTRA✭SPORT Floodlight

% LAMP LUMENS

8,000

LOWER VERTICAL BEAM

LUMENS–SUMMATION OF ONE SIDE ONLY

PHOTOMETRIC DATA

LUMENS–SUMMATION OF VERTICAL ZONES 35.8 35.1 33.8 32.1 29.9 27.1 23.4 18.4 11.0

% LAMP LUMENS

General Electric ULTRA✭SPORT™ Floodlight

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

4,000

3,000

2,000

1000

00

-45 -40 -35 -30 -25 -20 -15 -10 -5 VERTICAL–DOTTED LINE

0

5

10

DEGREES

20

25

30

35

40

45

HORIZONTAL–SOLID LINE

PHOTOMETRIC DATA LOWER VERTICAL BEAM

15

35-179087-00

CANDELA TRACES

UPPER VERTICAL BEAM

4,800

4,000

2,400

1,600

800

00

-45 -40 -35 -30 -25 -20 -15 -10 -5 VERTICAL–DOTTED LINE

0

5

10

LOWER VERTICAL BEAM

15

DEGREES

20

25

30

35

40

45

HORIZONTAL–SOLID LINE

PHOTOMETRIC DATA 6,400

35-179088-00

CANDELA TRACES

UPPER VERTICAL BEAM

5,600

4,800

4,000

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

3,200

2,400

1,600

800

00

-45 -40 -35 -30 -25 -20 -15 -10 -5 VERTICAL–DOTTED LINE

0

5

DEGREES

10

15

20

25

30

35

40

45

HORIZONTAL–SOLID LINE

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

0.9 1.0 1.2

0.5 400

45.5 40.8 32.1 22.9 15.1 10.3 8.2 7.5 7.0

0.5 0.5 0.5 0.5 0.5 0.5

1.1 1.0 0.5 0.8 0.7 0.7 0.7 0.7

0.4 0.4 0.4 0.6 6.9 12.8

30

25

20

15

10

5

0

0.3 0.3 0.5 0.5 1.0 1.1 1.7 1.8 2.6 3.0 3.8 4.8 5.6 7.8 7.3 11.6 9.4 17.0 4000

U P P E R B E A M

1.8 2.2 2.9 3.9 5.8 10.3 17.3 1.5 2.1 2.7 3.7 5.4 9.0 14.9 1.2 1.8 2.4 3.3 4.7 7.2 10.1 1.0 1.4 1.8 2.6 3.5 4.9 6.3 0.9 1.1 1.4 1.8 2.4 2.8 3.4 0.8 1.0 1.1 1.3 1.5 1.7 1.8 0.8 0.9 1.0 1.0 1.1 1.2 1.2 0.8 0.8 0.9 0.9 1.0 1.0 1.0 0.7 0.8 0.8 0.8 0.9 0.9 1.0 17.3 22.1 28.0 35.9 48.2 71.2 ****

L O W E R B E A M

0.2 0.3 0.4 0.7 0.9 1.1 1.3 1.5 1.6 700

0.2 0.3 0.5 0.8 1.1 1.4 1.7 1.9 2.1

0.2 0.4 0.7 1.0 1.4 1.8 2.2 2.5 2.8 1000

0.3 0.5 0.8 1.2 1.7 2.2 2.8 3.3 3.8

0.3 0.5 0.9 1.4 2.1 2.8 3.8 4.6 5.5 2000

18 16 14 12 10 8 6 4 2 0 0 -2 -4 -6 -8 -10 -12 -14 -16 -18

34.7 34.0 32.8 31.0 28.8 26.0 22.4 17.6 10.5

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES–DEGREES 19 19 18 17 15 14 11 8 4 4 8 11 13 14 15 15 16 16

45 5.7 7.4 10.0 13.4 17.9 23.8 30.8 38.3 43.8

40 35 0.3 0.4 0.3 0.5 0.3 0.6 0.4 0.7 0.4 0.7 0.5 0.9 0.5 0.9 0.6 1.0 0.6 1.0 400

30 25 20 0.5 0.6 0.7 0.6 0.7 0.8 0.7 0.9 1.0 0.8 1.1 1.3 1.0 1.3 1.7 1.2 1.6 2.0 1.3 1.8 2.4 1.4 1.9 2.6 1.5 2.0 2.8 700 1000

15 10 0.8 0.8 1.0 1.1 1.3 1.5 1.6 2.1 2.1 2.8 2.7 3.7 3.2 4.6 3.7 5.3 3.9 5.7 2000

42.9 37.3 27.9 19.0 12.0 7.8

0.5 0.5 0.4 0.4 0.4 0.4

1.5 1.4 1.1 0.9 0.7 0.6

3.9 3.5 2.9 2.2 1.5 2.0

5.7 4.6 3.8

1.0 0.9 0.7 0.6 0.6 0.5

2.0 1.9 1.6 1.2 0.9 0.7

2.8 2.6 2.2 1.7 1.2 0.8

5.7 5.3 4.2 3.0 1.9 1.2

0.3 0.5 0.5 0.6 0.6 0.7 0.8 0.3 0.4 0.5 0.5 0.5 0.6 0.6 0.2 0.3 0.4 0.4 0.4 0.5 0.5 7.2 12.3 16.7 21.8 28.1 36.9 50.7

50 0 0.8 0.8 1.2 1.2 1.8 1.9 2.5 2.9 3.5 4.3 5.0 6.4 6.7 9.4 8.3 13.5 9.5 16.7 4000 9.4 16.1 8.4 12.8 6.2 8.5 4.0 5.0 2.3 2.6 1.3 1.4 0.9 0.9 0.6 0.7 0.5 0.5 72.9 ***

U P P E R B E A M L O W E R B E A M

18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14 16 18

LUMENS–SUMMATION OF VERTICAL ZONES 35.2 34.5 33.3 31.6 29.4 26.6 22.9 17.8 10.5

% LAMP LUMENS

General Electric ULTRA✭SPORT Floodlight Reflector 35-430554-04, Refractor Clear Flat Glass Socket Position Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x2 BEAM SPREAD . . . . VERT.=24° . . . . . . . HORIZ.=70° BEAM EFFICIENCY . . . . . . . 54% BEAM FLUX . . . . . 536 LUMENS MAX. CANDELA . . . . . . . . . 5222

35 0.1 0.2 0.3 0.5 0.6 0.8

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES–DEGREES 17 17 16 16 14 13 11 8 4 4 8 11 12 14 15 15 16 17

45 2.5 4.2 7.1 11.1 15.9 21.6 29.0

40 0.1 0.1 0.2 0.3 0.3 0.4 0.5

35 0.1 0.2 0.3 0.5 0.6 0.8 0.9

36.4 41.5

0.5 0.5

41.9 35.9 27.2 18.8 12.9 9.7 8.3 7.5 7.0

0.4 1.0 1.6 2.1 2.8 3.9 5.8 9.6 14.8 0.4 0.9 1.4 2.0 2.6 3.5 5.3 8.2 11.6 0.4 0.8 1.1 1.6 2.2 3.0 4.1 6.0 7.9 0.4 0.7 1.0 1.3 1.7 2.2 3.0 3.9 4.6 0.4 0.7 0.8 1.0 1.3 1.6 2.1 2.4 2.6 0.4 0.6 0.8 0.9 1.1 1.2 1.4 1.6 1.7 0.4 0.6 0.8 0.8 0.9 1.0 1.1 1.2 1.4 0.4 0.6 0.7 0.8 0.9 0.9 1.0 1.1 1.2 0.3 0.5 0.7 0.7 0.8 0.9 0.9 1.0 1.1 6.5 12.0 16.7 21.7 27.8 36.3 49.7 71.6 96.2

1.0 1.1 400

30 0.2 0.3 0.4 0.7 0.9 1.1 1.3

25 0.2 0.3 0.6 0.9 1.2 1.5 1.7

20 0.3 0.4 0.7 1.1 1.5 1.9 2.3

1.5 2.0 2.6 1.6 2.1 2.8 700 1000

15 0.3 0.5 0.9 1.4 1.9 2.5 3.1 3.6 3.9

10 0.4 0.7 1.1 1.7 2.5 3.3 4.3

5.2 5.8 2000

50 0.5 0.8 1.3 2.2 3.2 4.5 6.4

0 0.4 U 0.8 P 1.5 P 2.4 E 3.8 R 5.6 B 8.5 E 8.2 11.8 A 9.5 14.4 M 4000 L O W E R B E A M

18 16 14 12 10 8 6 4 2 0 0 2 4 6 8 10 12 14

VERTICAL ANGLES–DEGREES

LUMINOUS INTENSITY–CANDELA

Reflector 35-430554-03, Refractor Clear Flat Glass Socket Position Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 4x2 BEAM SPREAD . . . . VERT.=24° . . . . . . . HORIZ.=64° BEAM EFFICIENCY . . . . . . . 54% BEAM FLUX . . . . . 539 LUMENS MAX. CANDELA . . . . . . . . . 6010

40 0.1 0.1 0.2 0.3 0.3 0.4 0.5 0.5

LUMENS–SUMMATION OF VERTICAL ZONES

General Electric ULTRA✭SPORT Floodlight

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

3,200

5 9 12 14 16 17 17 18 19

1.9 3.3 5.8 9.5 13.9 19.1 26.5 34.2 43.8

VERTICAL ANGLES–DEGREES

LUMINOUS INTENSITY–CANDELA

5,600

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

16 16 15 15 14 12 10 8 4

LUMENS–SUMMATION OF ONE SIDE ONLY

5,000

HORIZONTAL ANGLES–DEGREES 45

% LAMP LUMENS

LUMINOUS INTENSITY–CANDELA

6,000

ISOCANDELA CURVE LUMEN DISTRIBUTION

VERTICAL ANGLES–DEGREES

NEMA TYPE . . . . . . . . . . . 4hx2v BEAM SPREAD . . . . VERT.=22° . . . . . . . . . . . . . . HORIZ.=65° BEAM EFFICIENCY . . . . . . . 52% BEAM FLUX . . . . . 521 LUMENS MAX. CANDELA . . . . . . . . . 6275 TOTAL EFF. . . . . . . . . . . . . . . 84%

7,000

6,400

Reflector 35-430554-02, Refractor Clear Flat Glass Socket Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE

% LAMP LUMENS

UPPER VERTICAL BEAM

LUMENS–SUMMATION OF ONE SIDE ONLY

CANDELA TRACES

% LAMP LUMENS

8,000

LOWER VERTICAL BEAM

35-179086-00

LUMENS–SUMMATION OF ONE SIDE ONLY

PHOTOMETRIC DATA

16 18

LUMENS–SUMMATION OF VERTICAL ZONES 33.8 33.2 32.0 30.3 28.2 25.4 21.7 16.8

9.6

% LAMP LUMENS

21


3,200

2,400

1,600

800

00

-72 -64 -56 -48 -40 -32 -24 -16 -80 VERTICAL–DOTTED LINE

0

08

16

6,400

32

40

48

56

64

72

HORIZONTAL–SOLID LINE

PHOTOMETRIC DATA LOWER VERTICAL BEAM

24

DEGREES

35-179090-00

CANDELA TRACES

UPPER VERTICAL BEAM

4,800

4,000

2,400

1,600

800

00

-72 -64 -56 -48 -40 -32 -24 -16 -80 VERTICAL–DOTTED LINE

0

08

16

3200

32

40

48

56

64

72

HORIZONTAL–SOLID LINE

PHOTOMETRIC DATA LOWER VERTICAL BEAM

24

DEGREES

35-179412-01

CANDELA TRACES

UPPER VERTICAL BEAM

2400

2000

1200

800

400

00

-72 -64 -56 -48 -40 -32 -24 -16 -8 VERTICAL–DOTTED LINE

0

08

3,200 LOWER VERTICAL BEAM

16

24

DEGREES

PHOTOMETRIC DATA

32

40

48

56

64

72

HORIZONTAL–SOLID LINE

CANDELA TRACES

35-179413-01 UPPER VERTICAL BEAM

2,800

LUMINOUS INTENSITY CANDELA

2,000

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

1,200 800 400 00-72

-64 -56 -48 -40 -32 -24 -16 -8

VERTICAL DOTTED LINE

0

8

DEGREES

16 24

32

40

48 56

64

72

HORIZONTAL SOLID LINE

13 15 17 18 19 20 21

Reflector 35-430554-05, Refractor Clear Flat Glass Socket Position Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 5x4 BEAM SPREAD . . . . VERT.=53° . . . . . . . HORIZ.=73° BEAM EFFICIENCY . . . . . . . 70% BEAM FLUX . . . . . 703 LUMENS MAX. CANDELA . . . . . . . . . 2297 VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

VALUES OF CANDELA AN D LUMENS ARE BASED UPON A LAMP OPERATE D AT 1,000 LUM E NS. IF T HE D ATA IS DESIRED FOR A DIFFERENT L A M P L U M E N R AT I N G , MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DI FFE R EN T L A M P LU M E N RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

E A

0.1

0.3

0.8

1.3

2.0

2.9

0.0 0.0

0.1 0.1

0.6 0.8

1.4 2.1

2.4 3.4

3.6 5.3

5.0 7.5

41.6 54.3

0.0 0.0

0.0 0.0

0.1 0.1

56.6 45.4

0.0 0.0

0.0 0.0

0.1 0.1

0.9 0.9

3.1 2.6

5.6 4.7

30.6 20.5

0.0 0.0

0.0 0.0

0.1 0.2

0.9 0.9

2.2 2.0

3.6 2.9

16.3 13.8

0.0 0.0

0.0 0.0

0.2 0.1

0.9 0.8

1.9 1.6

11.5 9.5 7.9

0.0 0.0 0.0

0.0 0.0 0.0

0.1 0.1 0.1

0.7 0.6 0.4

1.4 1.1 0.9

0.0

0.2

1.8 11.0 28.0 45.1 67.3 98.7

M L

9.1 15.1 22.6 7.8 12.2 17.0 5.7 8.2 9.8

O W

5.5 4.1

E R

3.4 2.7

B E

2.2 1.9 ***

A M

3.9

5.0

2.5 2.2

3.1 2.6

3.7 3.0

1.8 1.5 1.3

2.2 1.8 1.5

2.5 2.1 1.8

15 12 9 6 3 0 0 3 6 9 12 15 18 21 24 27

38.2 38.2 38.1 38.0 36.9 34.1 29.6 22.8 13.0

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES–DEGREES 72 18 17 17 17

64

56

48

40

32

24

16

8

0 0.6

U

0.9 1.3

P P

1.8 2.2 2.2 3.1 3.9 3.8 5.3 6.6 5.4 8.0 9.8 7.4 11.6 15.8 8.8 14.5 21.6 2000

E R

2.0 2.8

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.2 0.2

0.3 0.4

0.4 0.5

0.5 0.7

0.1 0.2

0.3 0.4

0.5 0.7

0.7 1.2

1.1

4.0 6.6

0.0 0.0

0.0 0.0

0.0 0.0

12.0 20.5 29.9 43.4 54.7

0.0 0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0 0.0

0.1 0.1 0.1 0.1 0.1

52.7

0.0

0.0

0.1

0.9

2.8

5.4

39.9 26.4 18.2 15.2 12.9

0.0 0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0 0.0

0.1 0.1 0.1 0.1 0.1

0.9 0.9 0.9 0.8 0.7

2.3 2.0 1.9 1.7 1.5

4.2 3.2 2.6 2.3 2.0

8.6 14.0 21.0 7.0 10.7 14.6 4.9 7.1 8.2 3.5 4.4 4.9 2.8 3.4 3.9 2.4 2.8 3.2

18 19

10.8 9.0

0.0 0.0

0.0 0.0

0.1 0.1

0.6 0.5

1.3 1.1

1.7 1.4

2.1 1.7

19

7.3

0.0 0.1

0.0 0.2

0.1 0.4 0.9 1.2 1.4 1.6 1.9 10.7 26.9 43.7 64.9 94.9

16 15 13 10 5 5 9 12 14 15 17

0.4 0.9 0.6 1.5 0.8 2.2 0.9 2.8 1.0 3.1 200 400 700

1.5 2.5 3.6 4.7 5.6 1000

2.4 2.0

B E A M L O

2.6

W E R B E

2.1 1.7

A M

***

27 24 21 18 15 12 9 6 3 0 0 3 6 9 12 15 18 21 24 27

LUMENS–SUMMATION OF VERTICAL ZONES 36.8 36.8 36.8 36.6 35.6 32.9 28.5 22.0 12.5

% LAMP LUMENS

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES–DEGREES 16 16 16 15 14 13 12 9 5 5 10 15 19 22 23 24 25 25

72 64 56 48 40 32 24 16 80 0 2.7 0.0 0.0 0.0 0.0 0.0 0.1 0.5 0.8 1.1 U 4.5 0.0 0.0 0.0 0.0 0.2 0.6 1.0 1.3 1.4 P 5.9 0.0 0.0 0.0 0.1 0.5 1.0 1.3 1.5 1.6 P 7.8 0.0 0.0 0.0 0.2 0.8 1.3 1.6 1.9 2.0 E 10.7 0.0 0.0 0.0 0.4 1.1 1.7 2.1 2.6 2.8 R 15.8 0.0 0.0 0.0 0.6 1.4 2.2 3.1 3.9 4.6 B 25.2 0.0 0.0 0.1 0.7 1.8 2.9 4.6 6.7 8.6 E 39.6 51.6

0.0 0.0

0.0 0.0

0.1 0.1

0.8 0.9

53.1 49.4

0.0 0.0

0.0 0.0

0.1 0.1

1.0 0.9

45.5 40.6 28.8 15.4 8.1 5.3 3.3

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.6

2.0 2.2 200

A M

3.4 6.1 10.8 16.3 3.8 7.2 13.9 23.6 400 700 1000 2000

L O

2.5 4.3 7.7 13.7 23.8 2.8 5.1 8.3 13.1 19.2 0.7 3.0 5.5 8.5 12.4 15.4 0.6 2.8 5.3 8.1 11.0 12.8 0.4 2.2 4.3 6.1 7.6 8.1 0.3 1.4 2.8 3.6 3.8 3.5 0.1 0.6 1.4 2.0 2.0 1.9 0.1 0.2 0.7 1.2 1.5 1.6 0.0 0.1 0.2 0.6 1.0 1.4 8.0 25.5 46.6 73.6 *** ***

W E R B E A M

45 40 35 30 25 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45

LUMENS–SUMMATION OF VERTICAL ZONES 41.3 41.3 41.3 41.3 40.5 37.9 33.3 25.9 15.0

% LAMP LUMENS

General Electric ULTRA✭SPORT Floodlight

Reflector 35-430554-06, Refractor Clear Flat Glass Socket Position Horizontal LAMP 1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 5x4 BEAM SPREAD . . . . VERT.=54° . . . . . . . HORIZ.=74° BEAM EFFICIENCY . . . . . . .70% BEAM FLUX . . . . . 699 LUMENS MAX. CANDELA . . . . . . . . . .2147 TOTAL EFFICIENCY . . . . . . 81%

9.2 0.9 2.7 4.6 7.2 11.2 14.9 1.0 3.2 5.4 8.8 14.6 21.2 200 400 700 1000 2000

0.0

0.0 0.0

LUMENS–SUMMATION OF VERTICAL ZONES

General Electric ULTRA✭SPORT Floodlight

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

1,600

6 10

R B

0.0

19.5 28.4

21 18

ISOCANDELA CURVE LUMEN DISTRIBUTION HORIZONTAL ANGLES DEGREES

12

72 64 56 48 40 32 24 16 8 0 0.4 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 U 0.7 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 P

12

1.2

0.0

0.0

0.0

0.0

0.1

0.1

0.2

0.3

0.3

2.3

0.0

0.0

0.0

0.1

0.1

0.3

0.4

0.5

0.8

4.4 8.7

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.2

0.3 0.4

0.5 0.9

0.8 1.6

1.2 2.5

1.5 3.1

19.1

0.0

0.0

0.0

0.5

1.0

1.7

3.2

5.3

7.4

E

36.2

0.0

0.0

0.1

0.8

1.7

3.0

5.4

9.9 15.4

A

50.3

0.0

0.0

0.1

1.0

2.2

3.8 "

7.1 13.6 22.7 M %

52.4

0.0

0.0

0.1

1.1

2.6

4.5

7.8 13.8 22.6

49.7 49.5

0.0 0.0

0.0 0.0

0.1 0.1

1.1 1.0

3.1 3.5

5.4 6.1

45.3

0.0

0.0

0.1

0.9

3.5

6.2

8.6 13.1 18.4 O 9.4 13.3 16.2 W 9.1 12.0 13.5 E

33.4

0.0

0.0

0.1

0.7

2.9

5.2

7.1

8.5

9.0

R

19.2

0.0

0.0

0.0

0.5

1.9

3.5

4.4

4.5

4.4

12

12 12 11 11 9 5 5 10 15 20 23

P E R B

L

11.5

0.0

0.0

0.0

0.3

1.1

2.1

2.7

2.7

2.6

B E

27

8.5

0.0

0.0

0.0

0.1

0.5

1.2

1.9

2.3

2.5

A

28

5.6

0.0 0.0

0.0 0.0

0.0 0.7

0.0 0.1 0.5 1.1 1.7 2.1 8.2 25.0 45.1 71.2 **** ****

M

25 26

LUMENS SUMMATION OF VERTICAL ZONES 39.9 39.9 39.9 39.8 39.0 36.5 32.0 24.8 14.3

% LAMP LUMENS

45 40 35 30 25 20 15 10 5 0 0 -5

VERTICAL ANGLES DEGREES

2,400

22

Reflector 35-430554-06, Refractor Clear Flat Glass Socket Position Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 5x3 BEAM SPREAD . . . . VERT.=37° . . . . . . . HORIZ.=81° BEAM EFFICIENCY . . . . . . . 62% BEAM FLUX . . . . . 623 LUMENS MAX. CANDELA . . . . . . . . . 3237

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

1600

10 5

3.7 6.4

11.2

27 24

VERTICAL ANGLES–DEGREES

LUMINOUS INTENSITY–CANDELA

2800

14 12

General Electric ULTRA✭SPORT Floodlight

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

3,200

16 16

72 64 56 48 40 32 24 16 8 0 1.9 0.0 0.0 0.0 0.1 0.2 0.2 0.3 0.5 0.6 U 2.7 0.0 0.0 0.0 0.1 0.2 0.3 0.5 0.7 0.9 P 3.9 0.0 0.0 0.0 0.1 0.3 0.4 0.7 1.0 1.3 P 6.1 0.0 0.0 0.0 0.2 0.4 0.7 1.1 1.7 2.1 E

VERTICAL ANGLES–DEGREES

LUMINOUS INTENSITY–CANDELA

5,600

VALUES OF CANDELA AND LUMENS ARE BASED UPON A LAMP OPERATED AT 1,000 LUMENS. IF THE DATA IS DESIRED FOR A DIFFERENT LAMP LUMEN RATING, MULTIPLY ALL CANDELA AND LUMEN VALUES BY THE RATIO: DIFFERENT LAMP LUMEN RATING DIVIDED BY 1,000. PER 1000 LAMP LUMENS

17 17

% LAMP LUMENS

BASED ON IES 1971 STANDARD OF 10% MAXIMUM CANDELA

HORIZONTAL ANGLES–DEGREES 17

LUMENS–SUMMATION OF ONE SIDE ONLY

4,000

ISOCANDELA CURVE LUMEN DISTRIBUTION

% LAMP LUMENS

4,800

Reflector 35-430554-05, Refractor Clear Flat Glass Socket Position Fixed Horizontal LAMP–1500 TO 2000 WATT METAL HALIDE NEMA TYPE . . . . . . . . . . . . . . 5x3 BEAM SPREAD . . . . VERT.=38° . . . . . . . HORIZ.=81° BEAM EFFICIENCY . . . . . . . 65% BEAM FLUX . . . . . 652 LUMENS MAX. CANDELA . . . . . . . . . 3310

VERTICAL ANGLES–DEGREES

LUMINOUS INTENSITY–CANDELA

5,600

General Electric ULTRA✭SPORT Floodlight

LUMENS–SUMMATION OF ONE SIDE ONLY

UPPER VERTICAL BEAM

% LAMP LUMENS

35-179089-00

CANDELA TRACES

LUMENS–SUMMATION OF ONE SIDE ONLY

LOWER VERTICAL BEAM

% LAMP LUMENS

6,400

LUMENS SUMMATION OF ONE SIDE ONLY

PHOTOMETRIC DATA

-10 -15 -20 -25 -30 -35 -40 -45


Ultra✭Sport Accessories Safety Cable OSC-ULTS — 4 ft. (1.2 meters) OSC-ULTS001 — 6 ft. (1.8 meters)

Cross Arm Adapter CAA-001 — For 35° trunnion mounting with degree scale for preset aiming and 180° adjustment. CAUTION: No portion of this accessory should cantilever more than 2 inches beyond the front edge of the support structure.

23


Call us . . . We’re on your team. Toll free 1-877-806-8693

T

he GE Five-Year Fixture Failure Warranty is a limited warranty which guarantees to you, the Purchaser for resale or for use in business, that the factory-installed electrical system (consisting of a core and coil ballast, ignitor, capacitor, socket, terminal board, photoelectric receptacle and wiring) inside GE HID lighting fixtures will be free from defects in material and workmanship for five (5) years from the date of manufacture, or five (5) years from the date the fixtures are shipped from the GE factory, whichever period you can substantiate. (Products bear a date code from which date of manufacture can be determined.) If any GE HID fixture fails to meet this warranty, GE will ship either a repaired or replacement part F.O.B. its factory. GE makes no warranty to those defined as consumers in the Magnuson-Moss Federal Trade Commission. For a copy of the complete warranty, contact GE Lighting Systems, Inc., Hendersonville, NC 28793-4506.

e GE Sports Lighting Systems We know the game. 24

GE Sports Lighting Systems 8713 Airport Freeway, Suite 200 North Richland Hills, TX 76180 www.gelightingsystems.com

TM

OLP-2666A—2/02 (3M)GELS Trademark of General Electric Company


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.