RELIANCE

Page 1

RELIANCE ENERGY Interior Build-out

Schematic Design Meeting May 15, 2012

Gensler 212 Lavaca St Suite 390 Austin TX 78701 512.867.8100 512.867.8101


Server

IT Storage Copy/File

6 Asst. Asst.

Office 373 SF

Asst.

Library 292 SF Office 292 SF

Reliance Energy Gensler

Office

Office

263 SF 251 SF

Conference 26P

Office

Office

402 SF

408 SF

Interior Build-Out PLAN

Office

Gary's Office

409 SF

586 SF

05/15/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out 3D VIEWS

05/15/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out 3D VIEWS

05/15/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out 3D VIEWS

05/15/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out AXO

05/15/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out AXO

05/15/2012  2008 Gensler


RELIANCE ENERGY Interior Build-out

Preliminary Pricing Package May 17, 2012

Gensler 212 Lavaca St Suite 390 Austin TX 78701 512.867.8100 512.867.8101


Server ELEV. #4

ELEV. #1

ELEV. #5

ELEV. #2

1 FRONTS OF THESE WALLS ARE FULL HT WOOD VENEER PANELS WITH 10'-0" LENGTH OF FULL HEIGHT GLASS WALLS W/ WOOD MULLIONS & SLIDING GLASS DOORS W/ WOOD VENEER STILES

DN

151 SF 11

Break Rm 527 SF

IT Storage ELEV. #3 SERVICE ELEV.

177 SF

7 Copy/File FEC

345 SF

FE

FEC

12

4 Asst.

5

Office

4 Asst.

Asst.

373 SF

8 2

FEC

78' - 6"

9

3

75' - 1 1/8"

1

Library

1

292 SF Office

Office

292 SF

301 SF

Office 311 SF

Conference 18P 991 SF

6

Office

Office

Office

Office

344 SF

384 SF

368 SF

370 SF

434 SF FE

DL

Gary's Office

DL

DL

10

2 $25,000 RECEPTION DESK ALLOWANCE 3 FABRIC WRAPPED BANQUETTE AND FULL BACK INSET IN WOOD WALL SURROUND 4 GLASS SCREEN PARTIAL HT WALL 5 WOOD VENEER WALL 6 2 TV MONITORS FLUSH W/ WALL; PROVIDE BLOCKING AS REQUIRED 7 NEW SINK & FAUCET; PROVIDE CONNECTION FOR COFFEE MAKER, ICE, DISHWASHER 8 9'-0" FULL HT GLASS STOREFRONT W/ HERCULITE DOUBLE DOORS WITH CONCEALED CLOSERS 9 (2) 5'-0" X 8'-6" CENTER PIVOT HUNG GLASS DOORS W/ WOOD STILE AND CONCEALED CLOSERS. PROVIDE FILM FROM BOTTOM OF GLASS TO 7'-0 AFF 10 FULL HT WOOD VENEER WORK WALL CUSTOM WOOD CREDENZA W/ FULL HT WARDROBE AND OPEN SHELVING ABOVE; CREDENZA TO HAVE STONE TOP. TYP IN ALL OFFICES 11 WALLS DO NOT GO TO DECK BUT ARE 1 HR RATED, 1 4X8 PLYWOOD SHEETS AND CARD READER ACCESS 12 NEW 42" HT STONE COUNTER; GLASS BACKSPLASH; SSTL BAR SINK & FAUCET

GENERAL PRE-PRICING NOTES: 1. DEMOLISH EXISTING PARTITIONS; MILLWORK; FLOOR CORES; CEILINGS; DOORS & FRAMES AS REQUIRED FOR NEW WORK 2. ALL PARTITIONS TO BE FULL HT TO UNDERSIDE OF SLAB UNO; OFFICE FRONT PARTITIONS TO GO 6" PAST SCHED. CEILING 3. PROVIDE ACOUSTICAL BATTING IN ALL OFFICE PARTITIONS & CONF ROOM PARTITIONS 4. PROVIDE CLEAR ACOUSTICAL SEALANT AT ALL WALL PENETRATIONS 5. ALL TYPICAL NON-GLASS DOORS TO BE PAINTED SOLID CORE W/ WOOD VENEER WOOD FRAMES 6. PROVIDE DRYWALL COLUMN ENCLOSURES AS REQUIRED 7. PROVIDE BLOCKING FOR FURNITURE OVERHEADS AT EACH OFFICE

Reliance Energy Gensler

Interior Build-Out Pricing Plan - 1/16" = 1'-0"

05/17/2012  2008 Gensler


TR

VEST. 627

ELEV. #4 ELEV. #4

ELEC. 616 ELEV. #5 ELEV. #5

VEST. 628

ELEV. #1

ELEV. #1

ELEV. LOBBY 602

ELEV. #2

WOMENS RESTROOM 610

MENS RESTROOM 609

Server provide power as required

STAIR VESTIBULE 611

STAIR #2 608

ICE MWCOFF.DW+36+36FRIDGE

REF.

DN

MECH. RM #2 607

ELEV. #2

MECH. RM #1 617

ELEV. #3

ELEV. #3

R ULE

TELE. 615

SERVICE ELEV.

SERVICE ELEV.

VEST. 614

IT Storage

COPIER COPIER PLOTTER

FE

VP

J SIGNAGE

MINI +36COFF. FRIDGE V P

V P

CTV

AV

x2TVx2 x2 CTV

LEASE SPACE 604

FE

PRE-PRICING GENERAL NOTES: 1. FLUSH FLOOR MOUNTED POKE THRU FOR POWER/COMM, AND A/V IN CONFERENCE ROOMS W/ LOOSE CHAIRS AND TABLES. HAMMER DRILLS W/ CONDUIT, SLEEVE, AND HARDWIRING AT FIXED CONF. ROOM TABLE LOCATIONS 2. PROVIDE PRICING FOR REFRIGERATOR, MICROWAVE, DISHWASHER, & UNDERCOUNTER ICEMAKER FOR BREAK ROOM 3. PROVIDE CARD READERS AT EXIT DOORS & ELECTRIC DOOR RELEASE BUTTON AT RECEPTION DESK

Reliance Energy Gensler

Interior Build-Out Pricing Power/Comm - 1/16" = 1'-0"

05/17/2012  2008 Gensler


CL-2

CL-3

CL-2

CL-1 CL-4

CL-3

CL-1 CL-2

CL-2

CL-2

CL-2

CL-2

CL-2

8' - 6" CL-2

CL-2

CL-2 CL-1

CL-1 CEILING TYPE LEGEND: CL-1: PAINTED GYP BD CL-2: 24"X24" ARMSTRONG ULTIMA CEILING #1902 HRC; 9/16" INTERLUDE GRID CL-3: 24"X96" ARMSTRONG OPTIMA CEILING #3262; 9/16" INTERLUDE GRID CL-4: WOOD PLANK CEILING GENERAL PRELIM PRICING NOTES: 1. PROVIDE $9/SF ALLOWANCE FOR LIGHT FIXTURES 2. PROVIDE AXIOM TRIM AT DROPPED CEILING CONDITIONS 3. ALL CLG HTS TO BE 9'-0" AFF, UNO

Reliance Energy Gensler

Interior Build-Out Pricing RCP - 1/16" = 1'-0"

05/17/2012  2008 Gensler


Server ELEV. #4

DN

151 SF

ELEV. #1

SDT-1 ELEV. #5

Break Rm

ELEV. #2

527 SF 4

SDT-1

IT Storage

RT-1

Copy/File RT-1

ELEV. #3 SERVICE ELEV.

177 SF

345 SF FE

4 Asst.

1

CPT-1

Asst.

CPT-1

373 SF

Asst. ST-1

2

Office

6 Library

7

292 SF Office

Office

Office

292 SF 1

301 SF

311 SF

Conference 18P CPT-2

Office

Office

Office

Office

344 SF

384 SF

368 SF

370 SF

Gary's Office 434 SF

991 SF 5

CPT-1

1

CPT-2

FE DL

1 FABRIC WRAPPED PANELS WITH METAL PLATE BEHIND FOR MAGNETIC WALL, TYP AT ALL OFFICES 2 FABRIC WRAPPED PANEL IN WOOD VENEER WALL 3 MAGNETIC GLASS MARKERBOARD FULL EXTENT OF WALL 4 P.LAM UPPER AND LOWER CABINETS WITH GLASS COUNTERTOP & FULL HT GLASS TILE BACKSPLASH 5 PROVIDE ADD'L BLOCKING FOR TV AS WELL AS FABRIC WRAPPED PANELS, FABRIC ALLOWANCE OF $75/YD OF MATERIAL ONLY 6 FULL HT ROUGH CUT LIMESTONE WALL 7 FIXED GLASS, GL-1 WITH FIXED TOP AND BOTTOM & VERTICAL WOOD MULLIONS. PROVIDE FILM FROM BOTTOM OF GLASS TO 7'-0" AFF

DL

DL

FINISH CALLOUTS

3 CPT-1: $40/YARD CARPET INSTALLED CPT-2: $50/YARD CARPET INSTALLED ST-1: 12" X 24" STONE TILE RT-1: RESILIENT TILE SDT-1: STATIC DISSIPATIVE TILE GL-1: LOW IRON GLASS (AT WALLS & COUNTERTOPS)

GENERAL FINISH NOTES: 1. WOOD BASE AT ALL STONE FLOORING & WOOD VENEER PANELLED WALLS; PAINTED FLUSH WOOD BASE AT ALL OTHER WALLS 2. ALL WALLS TO PAINTED, UNO 3. ALL CARPET TO BE CPT-1, UNO 4. PROVIDE SSTL TRANSITION STRIPS WHERE REQUIRED 5. ALL FINISHES TO END AND START AT CENTER LINE OF DOOR OPENINGS 6. RUBBER BASE IN SUPPORT AREAS: BREAK ROOM; COPY RM; SERVER & IT

Reliance Energy Gensler

Interior Build-Out Pricing Finish Plan - 1/16" = 1'-0"

05/17/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out AXO

05/17/2012  2008 Gensler


Reliance Energy Gensler

Interior Build-Out AXO

05/17/2012  2008 Gensler


RELIANCE ENERGY Interior Build-out

Preliminary Millwork Package - Revised June 6, 2012

Gensler 212 Lavaca St Suite 390 Austin TX 78701 512.867.8100 512.867.8101


STORAGE

DN ELEV. #4

ELEV. #1

IT/SERVER BREAK RM ELEV. #5

ELEV. #2

6

WAR RM

ELEV. #3

11

SERVICE ELEV.

7

STORAGE OFFICE

2

1

3 4 4

OFFICE

OFFICE OFFICE OFFICE

OFFICE

10 9

OFFICE

8

CONFERENCE

OFFICE FE

8

8

OFFICE

8

9'-6" GLASS STOREFRONT W/ MATCHING WOOD MULLIONS & WOOD DOUBLE DOORS W/ GLASS INSETS; SYSTEM TO MATCH OFFICE FRONT WALL SCALE: 1/16" = 1'-0" COFFEE BAR; RE: ELEVATIONS COFFEE ISLAND; WD VENEER BASE CABINETS W/ TRAVERTINE COUNTERTOP OFFICE FRONTS; RE: ELEVATION BELOW RECEPTION DESK - TRAVERTINE COUNTERS W/ WD VENEER CASEWORK GENERAL NOTES BREAK ROOM PANTRY; RE: ELEVATION A. 2 1/2" FLUSH WOOD BASE IN RECEPTION AREA AND CONF. ROOM; ALL OTHER BASE TO BE RUBBER BREAK ROOM PANTRY; COUNTERTOP & BASE CABINETS ONLY. B. WD VENEER TBD WD VENEER WORK WALL. RE: ELEVATIONS; QUANTITY 6 C. MILLWORKER TO INCLUDE MAXIMUM ACOUSTICAL SOLUTIONS ON OFFICE FRONT & CONF. ROOM WALLS CREDENZA w/ TRAVERTINE TOP & WD VENEER BASE; FABRIC WRAPPED PANELS ABOVE 20 PERSON BOAT CONFERENCE TABLE; TRAVERTINE TOP W/ SSTL CENTER INLAY STORAGE MILLWORK: PLAM COUNTER W/ PLAM BASE & UPPER CABINETS; CONCEALLED DOWN & UPLIGHTING

8' - 6"

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.

8

8

2 PR 3.2

TYP GLASS OFFICE FRONT W/ WD MULLIONS & SLIDING WOOD DOOR AND GLASS INSET

RELIANCE Gensler

45" WIDE SLIDING DOORS (3) 6'-0" x8'-6" GLASS DOUBLE DOORS W/ WOOD VENEER FRAME

WOOD VENEER PANELING

Interior Build-Out Office Fronts

SCALE: 1/16" = 1'-0" 6.6.2012  2008 Gensler


8' - 6"

5' - 0"

WD VENEER CAP AT PARTITIONS BETWEEN OFFICES

WOOD PANELING

45" SLIDING G LASS DOOR W/ WOOD FRAME

SCALE: 3/8" = 1'-0"

10 EQ A

ALL VISIBLE SURFACES TO BE PLAM, UNO

2' - 5"

2' - 6 1/2"

BUILT IN PLAM MICROWAVE SURROUND W/ BASE CABINET

2' - 10"

5' - 3"

WHITE CONCRETE COUNTERTOP W/ CLR GLASS AGGREGATE

FRIDGE

6 EQ A

DISHWASHER ADA SINK

DRAWER PULL FOR WASTE/RECYCLE

RELIANCE Gensler

SCALE: 3/8" = 1'-0"

Interior Build-Out Typ. Office Front & Break Room Pantry

6.6.2012  2008 Gensler


1' - 6"

CONTINUOUS CONCEALED CAB. UPLIGHTING WHITE LACQUER UPPERS

2' - 2"

CONTINUOUS CONCEALED CAB. DOWNLIGHT PORCELAIN TILE BACKSPLASH TRAVERTINE COUNTERTOP

2' - 10"

WD VENEER BASE CABINETS

REMOVEABLE DOORS

PULL DRAWERS FOR WASTE/RECYCLE

BUILT IN UNDERCOUNTER FRIDGE W/ WD VENEER DOOR BUILT IN ICE MACHINE W/ WD VENEER DOOR

MIELE BUILT IN COFFEE SYSTEM W/ WD VENEER SURROUND

RELIANCE Gensler

Interior Build-Out Coffee Bar

SCALE: 3/8" = 1'-0"

6.6.2012  2008 Gensler


WOOD SOFFIT W/ REVEALS TO MATCH LINES OF BOTTOM; FIXED PANELS

1' - 4"

FABRIC WRAPPED PANELS

1' - 4"

TRAVERTINE TOP

EQ 2X2 FILES

RELIANCE Gensler

EQ EQ 2 W/ ADJ. SHELVING SINGLE PULL OUT FOR PRINTER 12' - 0"

Interior Build-Out Typ. Executive Work Wall

4"

2' - 7"

8' - 6"

1' - 4"

WD VENEER ON ALL OTHER SURFACES

6.6.2012  2008 Gensler


Gensler

RELIANCE

Architect 212 Lavace St, Ste. 390 Austin TX 78701 Telephone: 512.867.8100 Fax: 512.867.8101

Interior Build-Out MEJ & ASSOCIATES, INC Consulting Engineers 811 Barton Springs Road Suite 700 Austin, TX 78704 Telephone: 512.457.8771

ISSUE FOR PERMIT & CONSTRUCTION

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

6.18.2012 #EABPRJB2814932


SCOPE OF WORK

VICINITY MAP

DRAWING INDEX Sheet Number

10.5

10

9

8

DL

7

6.5

5.5

5

4

DL

DL

FE

3

2

1.1

DL

FE

O.H.

F DN ELEV. #4 ELEV. #4

ELEV. #1

ELEV. #1

ELEV. #5 ELEV. #5

ELEV. #2

LOCATION MAP

ELEV. #2

Sheet Name

Latest

Revisions Description

Date

Architectural A00.00 A00.01 A00.11 A00.30 A00.35 A00.80 A01.06 A02.06 A03.06 A04.06 A05.06 A06.06 A11.00 A11.01 A11.02 A12.00 A12.10

PROJECT INFORMATION GRAPHIC SYMBOLS & MOUNTING DIAGRAMS GENERAL NOTES DOOR SCHEDULE & DOOR DETAILS EQUIPMENT & FINISH SCHEDULES LIFE SAFETY PLAN DEMOLITION PLAN CONSTRUCTION PLAN POWER & COMMUNICATION PLAN REFLECTED CEILING PLAN FINISH PLAN FURNITURE PLAN INTERIOR ELEVATIONS INTERIOR ELEVATIONS INTERIOR ELEVATIONS PARTITION TYPES INTERIOR DETAILS

2 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 2

Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction

6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012 6.18.2012

Mechanical M02.06 MP01.00 MP03.01

MECHANICAL FLOOR PLAN LEVEL 6 MECHANICAL AND PLUMBING LEGENDS AND NOTES MECHANICAL AND PLUMBING DETAILS AND SCHEDULES

1 1 1

Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction

6.18.2012 6.18.2012 6.18.2012

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

ELEV. #3

ELEV. #3

SERVICE ELEV.

SERVICE ELEV.

UP

DN

D

FE

SCOPE OF WORK

FE

FE

B

DL

DL

DL

DL

Ref. North

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc.

Plumbing P02.06

PLUMBING FLOOR PLAN LEVEL 6

1

Issue for Permit & Construction

6.18.2012

Electrical E01.00 E01.06 E02.06 E03.01

ELECTRICAL COVER SHEET ELECTRICAL PLAN - LEVEL 6 LIGHTING PLAN - LEVEL 6 ELECTRICAL PANEL SCHEDULES

1 1 1 1

Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction Issue for Permit & Construction

6.18.2012 6.18.2012 6.18.2012 6.18.2012

MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

PROJECT INFORMATION PROJECT DESCRIPTION:

INTERIOR BUILD-OUT OF 6TH FL OFFICE SPACE WHICH INCLUDES NEW FINISHES, FURNITURE, MILLWORK, ELECTRICAL, PLUMBING, AND MINOR HVAC RE-WORK. NO SITE IMPROVEMENTS HAVE BEEN MADE.

PROJECT ADDRESS:

TERRACE 7 2801 VIA FORTUNA DRIVE SUITE 600 AUSTIN, TX 78746

OCCUPANCY TYPE:

B - BUSINESS

OCCUPANCY LOAD:

120 OCCUPANTS

CONSTRUCTION TYPE:

1A

BUILDING AREA:

12,054 SF

EXITS:

2 EXITS REQUIRED; 3 EXITS PROVIDED

STAIRS:

2 EXISTING

FIREPROOFING:

FULLY SPRINKLED

Issue Date 2 6.13.2012 3 6.18.2012

Description Issue for Pricing Issue for Permit & Construction

CITY OF AUSTIN CODE REQUIREMENTS:

2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL FIRE CODE (with local amendments) 2009 UNIFORM MECHANICAL CODE 2009 UNIFORM PLUMBING CODE 2011 NATIONAL ELECTRIC CODE 2009 INTERNATIONAL ENERGY CONSERVATION CODE 2012 TEXAS ACCESSIBILITY STANDARDS PROJECT

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description PROJECT INFORMATION

Scale As indicated

A00.00 © 2012 Gensler

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt


TYPICAL MOUNTING DIAGRAMS

GRAPHIC SYMBOLS

NOTE: DIMENSIONS ARE TO CENTER LINE OF DEVICES, TYP. FIRE STROBE DIMENSION IS TO THE BOTTOM OF THE DEVICE.

ELEVATION INDICATIONS

GRAPHIC SYMBOLS POWER & COMMUNICATION CONT'D

STONE

FIRE STROBE 6" TYP. U.O.N.

6'-8"

THERMOSTAT (WHEN USING DIMMERS, LOCATE THERMOSTAT OPPOSITE SIDE OF DOOR) TELEPHONE OR SECOND ROW OF SWITCHES

AV V P

FINISHED WOOD

4'-6"

LIGHT SWITCH, DOOR RELEASE BUTTON

3'-9" 3'-2" 1'-6"

PROXIMITY & KEYPAD ( CORR. SIDE) SECURITY ALARM KEYPAD (RM SIDE) GANG OF DIMMER SWITCHES ELECT/DATA OUTLETS

TYPICAL DEVICES @ DOOR (COORDINATE W/SPECIFIC PLAN & ELEVATION)

A

BRICK/CONCRETE BLOCK

MATCH HEIGHT OF DOOR LEVER TO EXISTING BASE BUILDING LEVER

GLASS AV

SECTION INDICATIONS

AV

SAND OR GROUT EARTH OR NATURAL GROUND POROUS FILL (GRAVEL) STONE

FIRE STROBE

CONCRETE

THERMOSTAT

6" TYP. U.O.N.

AV V

BRICK

P

TELEPHONE OR SECOND ROW OF SWITCHES 6'-8"

CONCRETE MASONRY UNIT

3'-9" 3'-2" 1'-6"

4'-6"

LIGHT SWITCH, DOOR RELEASE BUTTON, INTERCOM BUTTON

B

GANG OF DIMMER SWITCHES ELECT/DATA OUTLETS

NON-FERROUS ALUMINUM

WOOD (FINISH)

TYPICAL DEVICES @ EDGE CONDITION (COORDINATE W/SPECIFIC PLAN & ELEVATION)

AV

WOOD (CONTINUOUS)

V X PP

SECURITY DEVICES

P

WOOD (BLOCKING)

FIRE STROBE

AVT

EQ

EQ

THERMOSTAT

6'-8"

TELEPHONE OR SECOND ROW OF SWITCHES

4'-6"

LIGHT SWITCH

GLASS (LARGE SCALE)

ACOUSTICAL CEILING AND GRID MAIN RUNNER

GYPSUM BOARD

FLUORESCENT LIGHT FIXTURE

PLASTER WITH LATH

FLUORESCENT LIGHT FIXTURE/EMERGENCY CIRCUIT

3'-9" 3'-2" 1'-6" C

TYPICAL SINGLE DEVICES @ COLUMN (COORDINATE W/SPECIFIC PLAN & ELEVATION)

ELECTRIC LOCKSET

ES

ELECTRIC STRIKE

DR

DOOR RELEASE

MS

DOOR RELEASE MOTION SENSOR

DC

DOOR MONITOR CONTACT

ML

ELECTRO-MAGNETIC LOCK

KS

KEY SWITCH

H

DOOR HOLD OPEN

IC

INTERCOM

B

BELL PUSH BUTTON

DR

REMOTE DOOR RELEASE BUTTON

IA

INTRUSION ALARM

B

DOOR BELL

E

DENOTES EXISTING TO REMAIN

FLUSH FLOOR DEDICATED SINGLE

R

DENOTES EXISTING, RELOCATED FIXTURE

P

CEILING MOUNTED EXIT SIGN

6" MINIMUM PARTITION DEPTH PER TYPE

WALL MOUNTED EXIT SIGN RECESSED DOWNLIGHT ADJUSTABLE DOWNLIGHT RECESSED WALL WASHER TRACK LIGHTING

TYP. BACK TO BACK DEVICES (AT SAME HEIGHT) (COORDINATE WITH SPECIFIC PLAN & ELEVATION)

AV AV

SURFACE MOUNTED LIGHT FIXTURE WALL SCONCE EXHAUST FAN SD

SMOKE DETECTOR

ST

STROBE FIRE SPRINKLER SPEAKER

MS

T

MOTION SENSOR ACCESS DOOR

AV

SECURITY CAMERA

V P AV AV

THERMOSTAT LIGHT SWITCH

D

DIMMER SWITCH PROJECTION SCREEN RETURN AIR SUPPLY AIR

NOT IN CONTRACT

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE DEMOLISHED NEW PARTITION REFERENCE TO PARTITION TYPE

A

1 HR. RATED PARTITION 2 HR. RATED PARTITION 3 HR. RATED PARTITION 4 HR. RATED PARTITION SMOKE PARTITION EGRESS PATH

OFFICE 04F06

ROOM NAME ROOM NUMBER

XXXXXX

DOOR NUMBER (WITH SCHEDULE)

Gensler

MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

DOOR NUMBER (WITHOUT SCHEDULE) HARDWARE GROUP DOOR TYPE

XXXX XX XX

ALIGN

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc.

DOOR TYPE HARDWARE GROUP

XXX XXX

WALL MOUNTED DUPLEX WALL MOUNTED DEDICATED DUPLEX WALL MOUNTED SEPARATE DUPLEX WALL MOUNTED FOURPLEX WALL MOUNTED DEDICATED FOURPLEX WALL MOUNTED HALF DEDICATED FOURPLEX WALL MOUNTED VOICE RECEPTACLE WALL MOUNTED DATA RECEPTACLE WALL MOUNTED TELE/DATA RECEPTACLE WALL MOUNTED A/V TROUGH WALL MOUNTED A/V RECEPTACLE WALL MOUNTED CABLE TV RECEPTACLE WALL MOUNTED VOICE/DATA JUNCTION BOX WALL MOUNTED ELECTRICAL JUNCTION BOX WALL MOUNTED SYSTEMS PANEL VOICE/DATA INFEED WALL MOUNTED SYSTEMS PANEL POWER INFEED SURFACE MOUNTED FLOOR DUPLEX SURFACE MOUNTED FLOOR FOURPLEX SURFACE MOUNTED FLOOR DEDICATED DUPLEX SURFACE MOUNTED FLOOR SEPARATE DUPLEX SURFACE MOUNTED FLOOR DEDICATED FOURPLEX SURFACE MOUNTED FLOOR HALF DEDICATED FOURPLEX SURFACE MOUNTED FLOOR TELEPHONE RECEPTACLE

FLUSH FLOOR HALF DEDICATED FOURPLEX

AV V

DIMENSION OF CEILING ABOVE FINISH FLOOR

A

PIR (REQUEST TO EXIT, PASSIVE INFRARED DETECTOR) CEILING MOUNTED

LINEAR DIFFUSER

X'-X"

COLUMN GRID

DOUBLE DOOR MONITOR CONTACT

CIRCULAR DIFFUSER

X'-X" CEILING HEIGHT CHANGE

NOTE: CONTRACTOR TO COORDINATE LOCATION OF STUDS IN PARTITION TO ACHIEVE INTENT. PROVIDE ADDITIONAL STUDS/BRACING AS NEEDED. PROVIDE SOUNDLINERS AT DEVICE BACK BOXES WHERE DEVICES ARE LOCATED IN PARTITIONS WITH INSULATION.

EL

SURFACE MOUNTED FLOOR TELE/DATA RECEPTACLE SURFACE MOUNTED FLOOR DATA RECEPTACLE SURFACE MOUNTED FLOOR A/V RECEPTACLE SURFACE MOUNTED FLOOR SYSTEMS PANEL VOICE/DATA INFEED SURFACE MOUNTED FLOOR SYSTEMS PANEL POWER INFEED SURFACE MOUNTED FLOOR DUPLEX/VOICE/DATA SURFACE MOUNTED FLOOR FOURPLEX/VOICE/DATA SURFACE MOUNTED FLOOR DEDICATED DUPLEX/VOICE/DATA SURFACE MOUNTED FLOOR SEPARATE DUPLEX/VOICE/DATA SURFACE MOUNTED FLOOR DEDICATED FOURPLEX/VOICE/DATA SURFACE MOUNTED FLOOR HALF DEDICATED FOURPLEX/VOICE/DATA SURFACE MOUNTED FLOOR DUPLEX/AV/VOICE/DATA SURFACE MOUNTED FLOOR FOURPLEX/AV/VOICE/DATA SURFACE MOUNTED FLOOR POKE THRU DUPLEX SURFACE MOUNTED FLOOR POKE THRU FOURPLEX SURFACE MOUNTED FLOOR POKE THRU DEDICATED DUPLEX SURFACE MOUNTED FLOOR POKE THRU SEPARATE DUPLEX SURFACE MOUNTED FLOOR POKE THRU DEDICATED FOURPLEX SURFACE MOUNTED FLOOR POKE THRU HALF DEDICATED FOURPLEX SURFACE MOUNTED FLOOR POKE THRU TELEPHONE RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU TELE/DATA RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU DATA RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU A/V RECEPTACLE SURFACE MOUNTED FLOOR POKE THRU SYSTEMS PANEL VOICE/DATA SURFACE MOUNTED FLOOR POKE THRU SYSTEMS PANEL POWER INFEED SURFACE MOUNTED FLOOR POKE THRU DUPLEX/VOICE/DATA SURFACE MOUNTED FLOOR POKE THRU FOURPLEX/VOICE/DATA FLUSH FLOOR FLOOR DUPLEX FLUSH FLOOR FOURPLEX FLUSH FLOOR DEDICATED DUPLEX FLUSH FLOOR SEPARATE DUPLEX FLUSH FLOOR DEDICATED FOURPLEX

X'-X"

D

P

UNDER CABINET FLUORESCENT FIXTURE FLUORESCENT STRIP FIXTURE FLUORESCENT PENDANT FIXTURE

CARPET FABRIC WRAPPED PANEL

V

EXISTING TO BE REMOVED

ACOUSTICAL TILE

ELECT/DATA OUTLETS

J J

INSULATION (RIGID)

ELECTRIC HINGE

1

POWER & COMMUNICATION

AV

REFLECTED CEILING

EH

PIR

CTV

INSULATION (LOOSE OR BATT)

CARD READER

RELIANCE

ELEVATION DATUM POINT

FLUSH FLOOR POKE THRU SYSTEMS PANEL VOICE/DATA, POWER INFEED X= NUMBER OF VOICE/ DATA CABLES TO DEVICE POWER POLE ELECTRIC PIGTAIL

GRAPHIC SYMBOLS CONSTRUCTION

CR

DDC

FLUSH FLOOR POKE THRU DUPLEX/VOICE/DATA FLUSH FLOOR POKE THRU FOURPLEX/VOICE/DATA FLUSH FLOOR POKE THRU DEDICATED DUPLEX/VOICE/DATA FLUSH FLOOR POKE THRU SEPARATE DUPLEX/VOICE/DATA FLUSH FLOOR POKE THRU DEDICATED FOURPLEX/VOICE/DATA FLUSH FLOOR POKE THRU DUPLEX/AV/VOICE/DATA

METAL

PLYWOOD

FLUSH FLOOR TELEPHONE RECEPTACLE FLUSH FLOOR TELE/DATA RECEPTACLE FLUSH FLOOR DATA RECEPTACLE FLUSH FLOOR A/V RECEPTACLE FLUSH FLOOR SYSTEMS PANEL VOICE/DATA INFEED FLUSH FLOOR SYSTEMS PANEL POWER INFEED FLUSH FLOOR DUPLEX/VOICE/DATA FLUSH FLOOR DEDICATED DUPLEX/VOICE/DATA FLUSH FLOOR SEPARATE DUPLEX/VOICE/DATA FLUSH FLOOR DEDICATED FOURPLEX/VOICE/DATA FLUSH FLOOR HALF DEDICATED FOURPLEX/VOICE/DATA FLUSH FLOOR DUPLEX/AV/VOICE/DATA FLUSH FLOOR FLOOR FOURPLEX/AV/VOICE/DATA FLUSH FLOOR POKE THRU DUPLEX FLUSH FLOOR POKE THRU FOURPLEX FLUSH FLOOR POKE THRU DEDICATED DUPLEX FLUSH FLOOR POKE THRU SEPARATE DUPLEX FLUSH FLOOR POKE THRU DEDICATED FOURPLEX FLUSH FLOOR POKE THRU HALF DEDICATED FOURPLEX FLUSH FLOOR POKE THRU TELEPHONE RECEPTACLE FLUSH FLOOR POKE THRU TELE/DATA RECEPTACLE FLUSH FLOOR POKE THRU DATA RECEPTACLE FLUSH FLOOR POKE THRU A/V RECEPTACLE FLUSH FLOOR POKE THRU SYSTEMS PANEL VOICE/DATA INFEED FLUSH FLOOR POKE THRU SYSTEMS PANEL POWER INFEED

GRAPHIC SYMBOLS

ALIGN WITH ESTABLISHED SURFACES SHEET NOTE

XX

REVISION REFERENCE 1 A XX AXX.XX

XX AXX.XX FL12.NW SIM

LOCATION ON ROW WHERE SHOWN DIRECTION OF ELEVATION ROW ON ELEVATION SHEET WHERE SHOWN SHEET WHERE SHOWN DETAIL NUMBER SHEET WHERE SHOWN DESCRIPTION OF SIMILAR OR OPPOSITE FLOOR LEVEL AND AREA OR PHASE AREA TO BE DETAILED MILLWORK MILLWORK SCHEDULE TAG (IF USED)

XXXX FHC FE FEC FV FVC FA

FIRE HOSE CABINET FIRE EXTINGUISHER WITHOUT CABINET FIRE EXTINGUISHER CABINET FIRE VALVE WITHOUT CABINET FIRE VALVE CABINET FIRE ALARM PULL

Issue Date 2 6.13.2012 3 6.18.2012

Description Issue for Pricing Issue for Permit & Construction

FINISH XXXX XXXX

WALL FINISH BASE FINISH EXTENT OF FINISH

XXXX

WALL FINISH

XXXX

SPECIAL FINISH

XXXX

FLOOR FINISH

XXXX

CEILING FINISH CHANGE IN FLOOR FINISH

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description GRAPHIC SYMBOLS & MOUNTING DIAGRAMS

Scale As indicated

A00.01 NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

© 2012 Gensler


5'-0"

TYP. ACCESSIBILITY DETAILS

1. IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN RAMPS, PASSENGER ELEVATORS OR SPECIAL ACCESS LIFTS.

1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.

2. FLOOR SURFACES SHALL BE SLIP-RESISTANT.

2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS.

4. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2

4'-0"

X

5. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. MOUNT DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE FLOOR FINISH. Y

NOTE: X = 1'-0" IF DOOR HAS BOTH A CLOSER AND A LATCH

6. CENTER HAND ACTIVATED DOOR OPENING HARDWARE BETWEEN 30" AND 44" ABOVE THE FLOOR.

X

7. MAXIMUM PULL OR PUSH EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR INTERIOR DOORS, MEASURED AT RIGHT ANGLES TO HINGED DOORS AND AT CENTER PLANE OF SLIDING OR FOLDING DOORS. CORRESPONDING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET THE ABOVE STANDARDS. MAXIMUM EFFORT TO OPERATE REQUIRED FIRE DOORS MAY BE INCREASED NOT TO EXCEED 15 POUNDS.

NOTE: X =3'-0" MIN. IF Y=5'-0"; X= 3'-6" MIN. IF Y=4'-6".

Y

DEMOLITION NOTES

3. EVERY CORRIDOR AND AISLE SERVING AN OCCUPANT LOAD OF 10 OR MORE SHALL BE NOT LESS THAN 44" IN WIDTH.

1'-6"

2'-0"

NOTE: Y= 4'-0" MIN.; Y=4'-6" MIN. IF DOOR HAS A CLOSER

DISABLED ACCESS NOTES

8. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. PROVIDE A 10* HIGH SMOOTH PANEL ON THE PUSH SIDE OF NARROW FRAME DOORS.

4'-6"

Y

9. EVERY REQUIRED ENTRANCE OR PASSAGE DOORWAY SHALL BE NOT LESS THAN 3'-0" IN WIDTH AND NOT LESS THAN 6'-8" IN HEIGHT. DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES AND SHALL BE SO MOUNTED THAT THE CLEAR WIDTH OF THE DOORWAY IS NOT LESS THAN 32". 10. WHERE A PAIR OF DOORS IS UTILIZED, AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE LEAF POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.

NOTE: Y= 3'-6" MIN.; Y=4'-0" MIN. IF DOOR HAS A CLOSER

Y

11. IDENTIFY ACCESSIBLE ENTRANCES WITH AT LEAST ONE STANDARD SIGN AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, VISIBLE FROM APPROACHING PEDESTRIAN WAYS. 12. THE FLOOR OR LANDING ON EACH SIDE OF AN ENTRANCE OR PASSAGE DOOR SHALL BE LEVEL AND CLEAR. THE LEVEL AND CLEAR AREA \ SHALL HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 44" AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE DOOR IN ITS CLOSED POSITION. 13. FLOORS OR LANDINGS SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE DOORWAY. CHANGE IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2.

2'-0"

NOTE: Y= 3'-6" MIN.; Y=4'-0" MIN. IF DOOR HAS A CLOSER 4'-0" MIN.

14. TO ALERT THE VISUALLY IMPAIRED, MARK THE UPPER APPROACH AND THE LOWER TREAD OF EACH INTERIOR STAIR WITH A STRIP OF CLEARLY CONTRASTING COLOR AT LEAST 2" WIDE, PLACED PARALLEL TO AND NOT MORE THAN 1" FROM THE NOSE OF THE STEP OR LANDING. THE STRIP SHALL BE OF A MATERIAL THAT IS AT LEAST AS SLIP RESISTANT AS THE OTHER TREADS OF THE STAIR. 15. CENTER ELECTRICAL RECEPTACLE OUTLETS NOT LESS THAN 15" ABOVE THE FLOOR OR WORKING PLATFORM.

4'-0" MIN.

CLEARANCES

2

2

THRESHOLDS SCALE: FULL

5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. 8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. 9. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR AS REQUIRED FOR NEW FLOOR FINISHES.

REFLECTED CEILING NOTES 1. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20 % OF THE WEIGHT OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM. USE A MINIMUM CEILING WEIGHT OF 5 POUNDS PER SQUARE FOOT TO DETERMINE THE LATERAL FORCE. 2. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED: A. PROVIDE LATERAL SUPPORT BY FOUR WIRES OF MINIMUM NO. 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. B. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER TWO WALLS. C. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES. IN ADDITION, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL. D. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. 3. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED. 4. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH ADJACENT FINISH, UNLESS OTHERWISE NOTED.

5. COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. 6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION 7. COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS. 8. MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES. 9. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 10. MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION. COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY. 11. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. 12. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS OF FINISHES. 13. COORDINATE AND PROVIDE BACKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION 15. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE NOTED

FIRE DEPARTMENT NOTES 1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. 2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES.

17. ENTRY TO SANITARY FACILITIES: A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE. B. DOORWAYS TO HAVE A 32" CLEAR OPENING. C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM APPROACH.

4. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS.

POWER & COMMUNICATIONS NOTES

5. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES.

1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT AND COORDINATE LOCATIONS WITH OWNER.

6. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING AND SHALL BE SELF-CLOSING.

2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY SYSTEMS.

7. 20-MINUTE DOOR JAMBS TO BE TIGHT-FITTING, SMOKE AND DRAFT CONTROLLED.

3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION.

8. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA.

4. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER EQUIPMENT.

9. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS II, FLAME \ SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER LOCATION.

5. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. 6. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH TITLE 24 REQUIREMENTS. FOR ROOMS OR AREAS GREATER THAN 100 SQUARE FEET PROVIDE DOUBLE SWITCHES WITH EACH SWITCH CONTROLLING 50% OF LAMPS PER FIXTURE.

21. MOUNT FLUSH VALVE CONTROL NO MORE THAN 44" ABOVE THE FLOOR, ON THE SIDE OF THE TOILET WITH THE GREATEST SEPARATION FROM ADJACENT WALL OR OTHE SURFACE.

3

4. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.

3. PROVIDE EMERGENCY LIGHTING OF ONE FOOT-CANDLE AT FLOOR LEVEL. COMPLY WITHBUILDING CODES.

19. SINGLE ACCOMMODATION TOILET FACILITY A. WATER CLOSET TO HAVE A 28" CLEARANCE FROM A FIXTURE AND 32" FROM A WALL. B. MINIMUM CLEAR SPACE IN FRONT OF WATER CLOSET TO BE 48". C. A SPACE 36" X 48" IS PERMITTED IN FRONT OF EXISTING WATER CLOSET ACCESSIBLE TO THE HANDICAPPED. 20. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN 17" AND 19"

1

4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO COST TO THE OWNER.

1. COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK. 2. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. 3. REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION.

16. SANITARY FACILITIES LOCATED ON AN ACCESSIBLE FLOOR OF A BUILDINGSHALL BE ACCESSIBLE TO THE PHYSICALLY HANDICAPPED.

18. TOILET ROOM ACCESSORIES A. MOUNT BOTTOM EDGE OF MIRRORS NO HIGHER THAN 40" FROM THE FLOOR. B. MOUNT TOILET TISSUE DISPENSERS WITHIN 12" FROM THE FRONT EDGE OF THE TOILET SEAT. C. MOUNT DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY NAPKINS, WASTE, COIN SLOTS, ETC.) WITH OPERATING PARTS NO HIGHER THAN 40" FROM THE FLOOR.

1/4 " MAX

1/4" TO 1/2 "

SCALE: 1/2" = 1'-0"

3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES.

GENERAL NOTES

7. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS REQUIRED BY TITLE 24 AND ADA GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, 22. PROVIDE GRAB BARS ON EACH SIDE, OR ONE SIDE AND BACK OF WATER CLOSET. INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER LINE AT +3'-2" A. GRAB BARS TO BE 33" ABOVE AND PARALLEL TO THE FLOOR. B. SIDE BARS TO BE 42" LONG AND PROJECT 24" IN FRONT OF WATER CLOSET STOOL. GRAB BAR AT BACK TO BE 36" ABOVE FINISHED FLOOR. 8. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR LONG. CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. C. DIAMETER OF GRAB BARS TO BE 1-1/4" TO 1-1/2". D. PROVIDE 1-1/2" CLEARANCE BETWEEN GRAB BARS AND WALL. 9. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, ETC.) SHALL SUPPORT A 250 POUND LOAD. CAVITIES. DO NOT INSTALL BACK-TO-BACK. F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. G. GRAB BARS AND ANY ADJACENT SURFACE SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. 10. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. H. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8". PROVIDE ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. 23. PROVIDE A CLEAR FLOOR SPACE 30" X 48" IN FRONT OF LAVATORY TO PERMIT A FORWARD APPROACH. 11. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT. 24. MOUNT LAVATORIES WITH A MINIMUM CLEARANCE OF 29" FROM THE FLOOR TO THE BOTTOM OF THE APRON. PROVIDE KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30" IN WIDTH WITH 8" MINIMUM WIDTH, AND SHALL BE A MINIMUM OF 9" HIGH FROM THE FLOOR A MINIMUM OF 17" DEEP FROM THE FRONT OF THE LAVATORY. 25. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF 1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, AND ACCEPTABLE DESIGNS. SELF CLOSING ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 26. INSULATE OR OTHERWISE COVER HOT WATER AND DRAIN PIPES UNDER LAVATORIES.

FINISH NOTES

27. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES

2. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. 3. PROVIDE STRAIGHT, FLUSH RESILIENT BASE AT CARPETED AREAS,AND COVED, TOP SET RESILIENT BASE AT RESILIENT FLOORING, UNLESS OTHERWISE NOTED.

10. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE NONCOMBUSTIBLE OR BE FLAMEPROOFED IN AN APPROVED MANNER. 11. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. 12. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS.

ABBREVATIONS KITCHEN

L

LAV LB £ LT LVLG LVR

LAVATORY POUND BRITISH POUND (CURRENCY) LIGHT LEVELING LOUVER

M MAX MFD MFR MECH MET MEMB MEZZ MIN MISC MLWK MOIST MOT MTD

MAXIMUM MANUFACTURED MANUFACTURER MECHANICAL METAL MEMBRANE MEZZANINE MINIMUM MISCELLANEOUS MILLWORK MOISTURE MOTOR(IZED) MOUNTED

N NIC NO NTS

NOT IN CONTRACT NUMBER NOT TO SCALE

O ORNA OVFL OVHD OPNG OPR OH

ORNAMENTAL OVERFLOW OVERHEAD OPENING(S) OPERABLE OPPOSITE HAND

P PTN PEDTR PBD PNL POLYST PORT PREFIN PREFAB PLAM PLAS PLSTC PLYWD PRTECN

PARTITION PEDESTRIAN PARTICLE BOARD PANEL POLYSTYRENE PORTABLE PREFINISHED PREFABRICATED PLASTIC LAMINATE PLASTER PLASTIC PLYWOOD PROTECTION

R RDR RECES RECPT REF REFL REFR REQD RESIS REINF RESIL RFG RM RO

READER RECESSED RECEPTACLE REFER(ENCE) REFLECTED REFRIGERATOR REQUIRED RESIST(ANT)(IVE) REINFORCE(D)(ING)(MENT) RESILIENT ROOFING ROOM ROUGH

F FAB FABRICATION FD FLOOR DRAIN FE FIRE EXTINGUISHER FE&C FIRE EXTINGUISHER AND CABINET FHC FIRE HOSE CABINET FIN FINISH FLDG FOLDING FPLC FIREPLACE FR FIREPLACE FRMG FRAMING FXD FIXED FXTR FIXTURE FLR FLOOR(ING) FURN FURNITURE FWC FABRIC WALL COVERING

S SCR SECUR SF SGL SHORG SIM SST STD STL STRFR

SCRIBE SECURITY SQUARE FEET SINGLE SHORING SIMILAR STAINLESS STEEL STANDARD STEEL STOREFRONT

STRUCT SURF SYSTEM(S) SUSP

STRUCTURAL SURFACE SYS SUSPENDED

G GA GAUGE GFRC GLASS FIBER REINFORCED CONCRETE GFRG GLASS FIBER REINFORCED GYPSUM GFRP GLASS FIBER REINFORCED PLASTER GL GLASS GR GRAD(E)(ING) GYP GYPSUM

T THK TLT TRAF TRANS TRTD T&G TYP

THICK TOILET TRAFFIC TRANSPARENT TREATED TONGUE AND GROOVE TYPICAL

H HD HEAD HDWD HARDWOOD HDWE HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HVAC HEATING, VENTILATING, AND AIR CONDITIONING

U UNDRLAY UTIL UNO

UNDERLAYMENT UTILITY UNLESS NOTED OTHERWISE

V VEH VERT VIF

VEHICLE VERTICAL VERIFY IN FIELD

B BLDG BOLLD BD BLKG BRDLM BU

BUILDING BOLLARD BOARD BLOCKING BROADLOOM BUILT UP

C CAB CABINET CPT CARPET CEM CEMENT(ITIOUS) CER CERAMIC CLG CEILING COATG COATING COILG COILING CONC CONCRETE CONSTR CONSTRUCTION CONT CONTINUOUS(ATION) CONTR CONTRACT(OR) COV COVER CMU CONCRETE MASONRY UNIT D DBL DOUBLE DEPT DEPARTMENT DES DESIGN(ED) DET DETAIL DF DRINKING FOUNTAIN DIA DIAMETER DIFF DIFFUSER DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN $ DOLLAR (US CURRENCY) DR DOOR DSCON DISCONNECT DWR DRAWER E ELAST ELEC EMBED ENGR ENTR

ELASTOMERIC ELECTRICAL EMBEDD(ED)(ING) ENGINEER(ED) ENTRANCE

II EQ EQUAL EQUIP EQUIPMENT EXIST EXISTING EXP EXPANSION JT JOINT EXPS EXPOSE(D) EXT EXTERIOR

14. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN APPROVED FIRE/ LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL PRIOR TO INSTALLATION.

I INFO INFORMATION INSTRUM INSTRUMENT(ATION) INSUL INSULATION INTLK INTERLOCK(ING) INT INTERIOR INFILTR INFILTRATION

15. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK.

J JAN

13. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS.

K KIT

A ACCES ACCESSORY ACOUS ACOUSTIC(AL) AFF ABOVE FINISHED FLOOR AL ALUMINUM ALT ALTERNATE ANNUNC ANNUNCIATOR ANOD ANODIZED APPL APPLIANCE ARCH ARCHITECT(URAL) AUTO AUTOMATIC AVG AVERAGE & AND

JANITOR

W W/ WC WD WDW W/O WT WTRPRF

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

Issue Date 2 6.13.2012 3 6.18.2012

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

17. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION.

Description GENERAL NOTES

18. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION.

Scale As indicated

A00.11 NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

Description Issue for Pricing Issue for Permit & Construction

Seal/Signature

WITH WATER CLOSET WOOD WINDOW WITHOUT WEIGHT WATERPROOFING

16. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE.

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

© 2012 Gensler


6' - 0"

6"

6"

6"

6"

6"

3' - 9"

RELIANCE

6"

9' - 0"

9' - 0"

6"

GL-2

6"

GL-1 6"

10"

10"

GL-1

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

DOOR TYPE 'A'

DOOR TYPE 'B'

DOOR TYPE 'C'

DOOR TYPE 'D'

DOOR TYPE 'E'

DOOR TYPES

1

SCALE: 1/4" = 1'-0"

Door Schedule Assembly

Leaf

Assembly Rating

Frame

Dimensions Type A B C D E

Width 3' - 0" 5' - 9 1/2"

Details Thickness 0' - 1 3/4"

3' - 9"

Height 9' - 0" 9' - 2"ELEV. RE: RE: ELEV. 8' - 6" 8' - 2" RE: ELEV.

RE: PLAN

9' - 0"

0' - 1 3/4"

6' - 0"

Material SOLID CORE WOOD & GLASS WOOD & GLASS WOOD & GLASS SOLID CORE

Finish MATCH P-1 WD-1 & CLR

Material ALUMN

WD-1 & CLR MATCH P-1

Finish P-1 WD-1 WD-1

FRAMELESS

Frame Detail LUT KEY (none) (none) (none) (none)

Head

Jamb

Sill

Fire Rating

Hardware Comments ASSUME BUILDING STANDARDS SSTL DOOR PULLS LENGTH OF GLASS W/ 4'-0" SP-4 LEATHER ACCENT

Gensler

SLIDING HDWARE BY MLWKR; SSTL DOOR PULLS LEGNTH OF GLASS W/ 4'-0" SP-4 LEATHER ACCENT

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

(none)

1 1/2"

DOOR HARDWARE SCHEDULE

SCHEDULED CEILING; REFER TO CEILING PLAN ALUMINUM DOOR FRAME DOOR SILENCER SCHEDULED DOOR; REFER TO DOOR SCHEDULE Issue Date 2 6.13.2012 3 6.18.2012

LINE OF JAMB BEYOND. COORD W/ JAMB

ALUMINUM DOOR HEAD

Description Issue for Pricing Issue for Permit & Construction

2

SCALE: 3" = 1'-0"

SCHEDULED ADJACENT PARTITION WHERE OCCURS; REFER TO CONSTRUCTION PLAN SCHEDULED PARTITION; REFER TO CONSTRUCTION PLAN. CONTRACTOR TO VERIFY THICKNESS

4"

VARIES

SCHEDULED DOOR; REFER TO DOOR SCHEDULE

DOOR SILENCER 1 1/2"

BLOCKING ALUMINUM DOOR FRAME

ALUMINUM DOOR JAMB SCALE: 3" = 1'-0"

Seal/Signature

3

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description DOOR SCHEDULE & DOOR DETAILS

Scale As indicated

A00.30 NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

© 2012 Gensler


SYMBOL MANUFACTURER/DESCRIPTION SPECIALTY MANUFACTURER: CHAT-BOARD SP-2 STYLE: 120 x 200 cm (47.2" X 78.7")

SYMBOL MANUFACTURER/DESCRIPTION

SYMBOL MANUFACTURER/DESCRIPTION CEILING MANUFACTURER: -CL-1 STYLE: --

COLOR: DESCRIPTION:

MOCCA MAGNETIC MARKER BOARD

COLOR: DESCRIPTION:

PAINT TO MATCH P-1 PAINTED GYP BD

COLOR: DESCRIPTION:

SILVER LINING EGGSHELL FINISH; LOW VOC INTERIOR PAINT

LOCATION: NOTE:

@ EXECUTIVE OFFICES; RE: FINISH PLAN INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

RE: RCP INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

ALL WALLS, U.N.O. & CEILING INSTALL PER MANUFACTURER'S REQUIREMENTS

SPECIALTY SP-3

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

EGAN --MAGNETIC MARKERBOARD WALLCOVERING

LOCATION: NOTE:

@ WAR ROOM FLOOR TO CLG: RE: FINISH PLAN INSTALL PER MANUFACTURER'S REQUIREMENTS

CL-2

CL-3

SPINNYBECK TBD TBD 2'-0" LEATHER WRAP

LOCATION: NOTE:

AT DOOR PULLS; RE: A00.30 CONTACT BARBARA SCHMIDT FOR MORE INFO; 713.827.8282

SPECIALTY SP-5

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

ARMSTRONG -WHITE 24x24 ULTIMA 1911 HRC w/ 15/16" PRELUDE GRID

LOCATION: NOTE:

RE: RCP INSTALL PER MANUFACTURER'S REQUIREMENTS

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

MECHOSHADE TBD TBD MOTORIZED WINDOW SHADE

LOCATION: NOTE:

CONFERENCE ROOM PART OF AV PACKAGE

LQ-1

PL-1

WB-1

RB-1

ML-1

EQUIPMENT SCHEDULE Equipment Schedule Description UNDERCOUNTER ICE MACHINE UNDERCOUNTER FRIDGE BUILT IN COFFEE SYSTEM REFRIGERATOR DISHWASHER MICORWAVE COPIER PLOTTER 82-84" TV MONITOR 42" TV MONITOR COFFEE VIDEO CAMERA

Manufacturer SUMMIT SUMMIT MIELE GE ASKO GE

TBD

Model BIM44ADA SP6DS2D7ADA CVA4066 PDCS1NCZ D5634ADAHS PEB2060SMSS

TBD

FWP-1

PF.1 PF.2 PF.3 PF.4

Description COFFEE BAR SINK COFFEE BAR FAUCET BREAK ROOM SINK BREAK ROOM FAUCET

Manufacturer MILA HANSGROHE ELKAY KOHLER

Model ATELIER MES-801 TALIS S BAR GECR2521 K-7507

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

BROCHSTEINS EAST INDIAN LAUREL NATURAL KT671AZ WOOD VENEER

LOCATION: NOTE:

RE: ELEVATIONS & MILLWORK DETAILS --

Gensler

ARMSTRONG -WHITE 24X96 OPTIMA PLANKS 3282 w/ 15/16" PRELUDE GRID

LOCATION: NOTE:

RE: RCP INSTALL PER MANUFACTURER'S REQUIREMENTS

ST-1

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

DALTILE HONED MARBLE 12X24 CALCUTTA GOLD

LOCATION: NOTE:

RE: FINISH PLAN INSTALL PER MANUFACTURER'S REQUIREMENTS; INSTALL RUNNING BOND LAYOUT

LACQUER

STONE

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

BROCHSTEINS OPAQUE FINISH WHITE LACQUER

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

-HONED TBD LIMESTONE

LOCATION: NOTE:

UPPER CABINETS AT COFFEE BAR INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

RECEPTION & FEATURE WALL INSTALL PER MANUFACTURER'S REQUIREMENTS

ST-2

PLASTIC LAMINATE

STONE

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

FORMICA 949 WHITE MATTE FINISH

ST-3

RE: ELEVATIONS & MILLWORK DTLS INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

MILLWORKER PAINTED TO MATCH WALL ABOVE 2 1/2" H FLUSH WOOD BASE

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

CONCEPT SURFACES PACIFIC PLATA POLISHED 10X20 ACCENT TILE

LOCATION: NOTE:

RE: FINISH PLAN INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

COFFEE BAR BACKSPLASH INSTALL PER MANUFACTURER'S REQUIREMENTS; CONTACT ELLENA MILLS @ CONCEPT SURFACES; 512.731.8467; ellenam@conceptsurfaces.com

RESILIENT BASE

GLAZING

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

JOHNSONITE STRAIGHT WHITE SAND 68 2 1/2" H RUBBER BASE; CONTINUOUS ROLL

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

-LAMINATED GLASS CLEAR --

LOCATION: NOTE:

RE: FINISH PLAN INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

OFFICE FRONTS PRICE ALTERNATE FOR CLEAR TEMPERED GLASS FOR GL-1 & GL-2

MARMOLEUM

GLAZING

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

FORBO FLOORING WALTON CROCODILES ESPRESSO CROCO C184 MARMOLEUM FLOORING

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

---SWITCHABLE GLASS

LOCATION: NOTE:

RE: FINISH PLAN INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

CONFERENCE ROOM FRONTS --

GL-2

Issue Date 2 6.13.2012 3 6.18.2012

WORK WALL & COFFEE BAR COUNTERTOPS INSTALL PER MANUFACTURER'S REQUIREMENTS; INSTALL RUNNING BOND LAYOUT

PORCELAIN TILE

GL-1

MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

--TBD TRAVERTINE

WOOD BASE PT-1

CARPET

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

TBD TBD TBD $18 ALLOWANCE / SY

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

BLOOMSBURG CONTEXT VELVET V1450/35 SILVER NYLON BROADLOOM CARPET

LOCATION: NOTE:

AT WORK WALLS INSTALL PER MANUFACTURER'S REQUIREMENTS

LOCATION: NOTE:

RE: FINISH PLAN --

Description Issue for Pricing Issue for Permit & Construction

Seal/Signature

06.18.2012

CONCRETE

SPECIALTY

Comments

SP-1 PROVIDE GARBAGE DISPOSAL

FABRIC WRAPPED PANELS CP-1

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

---CORE DRILL SAMPLES PROVIDED BY RELIANCE

LOCATION: NOTE:

FEATURE WALL --

CO-1

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc.

Project Name Interior Build-Out

Project Number 25.1098.000

Description EQUIPMENT & FINISH SCHEDULES

Plumbing Fixture Schedule Type Mark

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

SSTL DOOR SSTL DOORS

PURCHASED & INSTALLED BY OWNER PURCHASED & INSTALLED BY OWNER BY AV VENDOR; GC TO INSTALL & PROVIDE MOUNT PURCHASED & INSTALLED BY OWNER; GC TO PROVIDE MOUNT PURCHASED & INSTALLED BY OWNER BY AV VENDOR

TBD

TBD

Comments

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

STONE

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

LOCATION: NOTE:

Type Mark E.1 E.2 E.3 E.4 E.5 E.6 E.7 E.8 E.9 E.10 E.11 E.12

WD-1

CEILING

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

RELIANCE

WOOD

CEILING

SPECIALTY SP-4

SYMBOL MANUFACTURER/DESCRIPTION PAINT MANUFACTURER: PRATT AND LAMBERT P-1 STYLE: --

MANUFACTURER: STYLE: COLOR: DESCRIPTION:

NEWBOLD STONE SAND: MARBLE DUST TRIPLE WHITE EXPOSED CLEAR GLASS AGGREGATE IN CONCRETE

LOCATION: NOTE:

BREAK ROOM COUNTERTOP CONTACT JOHN NEWBOLD @ NEWBOLD STONE FOR MORE INFO; 512.646.7405; john@newboldstone.com

Scale 1:1

A00.35 © 2012 Gensler


RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler 10.5

10

9

8

7

6.5

5.5

5

4

3

2

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

1.1

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

J

H

18' - 10 147/256" ROUTE A F

DN

ELEV. #2

36' - 11 133/256"

ELEV. #5 ELEV. #5

ELEV. #2

Issue Date 2 6.13.2012 3 6.18.2012

28" TH 5/1 0 PA 1 N ' O 13 MM CO

ELEV. #1

ROUTE A

ELEV. #1

EXIT A

Description Issue for Pricing Issue for Permit & Construction

15' - 0" PATH COMMON

ELEV. #4 ELEV. #4

ELEV. #3

ELEV. #3

SERVICE ELEV.

DN

UP

74' - 5 3/256" ROUTE B

24' - 6" ROUTE B

6' - 1 189/256"

EXIT B 36' - 11 75/256"

ROUTE B

17' -

6" B '9 1 TE U RO

9 55 /128 " ROU TE B

COMMON PATH

8" 9' - 7 61/12 PATH COMMON

SERVICE ELEV.

D

POINT OF DECISION

C

FE DL

DL

DL B

Seal/Signature

LIFE SAFETY PATHS: COMMON PATH OF TRAVEL EXIT ROUTE A: EXIT ROUTE B:

DISTANCE 75'-7" 37'-0 140'-6"

TOTAL -112'-7" 216'-1"

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description LIFE SAFETY PLAN

Scale 1" = 10'-0"

A00.80 EGRESS PLAN - LEVEL 06 SCALE: 1" = 10'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

© 2012 Gensler


SHEET NOTES 1

REMOVE EXTENT OF EXISTING PARTITION AS SHOWN FOR NEW ENTRY/EXIT. 2 REMOVE EXISTING PARTITIONS, ELECTRICAL RECEPTACLES & FLOOR FINISHES 3 EXISTING GWB COLUMN ENCLOSURES TO REMAIN. REMOVE EXISTING WALL BASE. 4 REMOVE EXISTING STONE WALL 5 REMOVE EXISTING CEILING SOFFIT 6 REMOVE EXISTING MILLWORK & EQUIPMENT 7 REMOVE ALL EXISTING FLOOR FINISHES THROUGHOUT AREA OF WORK 8 REMOVE ALL EXISTING GWB CEILINGS, CEILING GRIDS & PANELS, LIGHT FIXTURES, U.N.O. 9 REMOVE EXIST. ELECTRICAL RECEPTACLES, CEILING, AND WALL & FLOOR FINISHES IN THIS ROOM. 10 EXISTING PLUMBING CONNECTION TO REMAIN. 11 ALL EXIST. RECEPTACLES, HVAC IN THIS ROOM TO REMAIN. 12 EXIST. DOOR, FRAME & HARDWARE TO REMAIN.

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc.

TR

MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

REF.

F 12 ELEV. #4 ELEV. #4

DN

9

ELEV. #1

ELEV. #1

11 12 ELEV. #5 ELEV. #5

ELEV. #2

ELEV. #2

9

6

ELEV. #3

ELEV. #3

9

SERVICE ELEV. SERVICE ELEV.

10 9

6

D

PARTITION LEGEND EXISTING TO REMAIN 1

DEMOLISH

1

5' - 6"

2

2 7

Description Issue for Pricing Issue for Pricing Issue for Permit & Construction

GENERAL NOTES

2

8

Issue Date 1 5.25.2012 2 6.13.2012 3 6.18.2012

6

8

A REMOVE ALL EXISTING WALL BASE, U.N.O. 5

B REMOVE ALL EXISTING CEILING (GYP BD, CEILING PANELS & GRID) AND LIGHT FIXTURES, U.N.O.

4

C REMOVE ALL EXISTING POWER & COMMUNICATIONS RECEPTACLES, U.N.O. D EXISTING HVAC EQUIPMENT AND DUCTWORK TO REMAIN

6

E ALL EXISTING PERIMETER SLOT DIFFUSERS TO REMAIN F ALL EXISTING PERIMETER GWB COLUMN ENCLOSURES TO REMAIN

2 2

B

G REMOVE & SALVAGE ALL EXISTING FIRE EXTINGUISHERS & CABINETS FOR NEW CONSTRUCTION REUSE DL

3

3

A

2 TYP

3

3

DL

3

3

DL

3

H REMOVE & SALVAGE ALL EXISTING WHITE NOISE EQUIPMENT & SALVAGE FOR NEW CONSTRUCTION REUSE I REMOVE & SALVAGE ANY EXISTING 24X24 DIFFUSERS IN GOOD AND WORKING CONDITION FOR NEW CONSTRUCTION REUSE

8

7

6.5

5.5

5

4

3

2

J REMOVE & SALVAGE EXISTING DOORS AND DOOR FRAMES IN GOOD AND WORKING CONDITION FOR NEW CONSTRUCTION REUSE

1.1

K EXISTING EXISTING SPRINKLER HEADS AND EXIT SIGNS TO REMAIN. REMOVE & SALVAGE EXISTING FIRE ALARM DEVICES FOR REUSE L ALL EXIST. WINDOW BLINDS TO REMAIN Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description DEMOLITION PLAN

Scale As indicated Ref. North

A01.06 DEMOLITION PLAN - LEVEL 06 SCALE: 1/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


SHEET NOTES 1 EXISTING PARTITION W/ NEW FINISHES IN SUITE 2 PROVIDE ALTERNATE PRICING FOR OFFICE FRONT WALL TO GO TO DECK 3 PROVIDE ALTERNATE PRICING FOR CONFERENCE RM GLASS TO BE SWITCHABLE GLASS 4 PROVIDE COAT ROD AND SHELF ABOVE 5 PROVIDE BLOCKING IN WALL FOR WALL MOUNTED CASEWORK AND/OR CHATBOARDS 6 PROVIDE MARKERBOARD TRAY ALONG THIS WALL 7 PROVIDE ALTERNATE PRICING FOR CLR TEMPERED GLASS IN OFFICE WALL SYSTEM. 8 FURR OUT NEW PARTITIONS TIGHT TO COLUMN AS POSSIBLE 9 EXIST. DOOR AND FRAME TO REMAIN. PAINT FRAME AND DOOR TO MATCH P-1

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler 8

7

6.5

5.5

5

4

3

2

1.1

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

9

F

CR A 2 ELEV. #4 ELEV. #4

DN

ELEV. #1

ELEV. #1

STORAGE 613

2' - 0" TYP

1 ELEV. #5 ELEV. #5

ELEV. #2

3

ELEV. #2

A11.01 PR 3.2

A 3

ELEV. #3

ELEV. #3

SERVICE ELEV.

1

FEC

4

6

2' - 0"

D

CR

A11.00 13 4

1

5

4

STORAGE 618

7

5

6

A11.01

A11.01

ALIGN

COPY/FILE 615

8

OFFICE 612

EQ

5

1

A11.00

8

3

3

2

5

Description Issue for Pricing Issue for Permit & Construction

ALL PARTITIONS TYPE A3A, U.N.O. ALL DOORS TO BE A1, U.N.O. ALL A TYPE DOORS ARE SALVAGED AND RE-USD FROM PRIOR TENANT. RE: A00.30 FOR DOOR FINISHES ALL EXISTING DOORS & FRAMES TO BE PAINTED P-1

21' - 8" OFFICE 611

ALIGN

5

Issue Date 2 6.13.2012 3 6.18.2012

A3B

10"

C

ALIGN

A. B. C. D.

A11.00

5' - 0"

7

8 ALIGN

10' - 0"

A11.00

A11.00

A11.00

1

D

GENERAL NOTES

WORKSTATION 622

EQ 4

2

2' - 0"

E

4' - 0"

8

EQ

10' - 0"

12' - 6"

FEC

5' - 6"

7

EQ

1

A 2

E

12' - 4 1/4"

B

2' - 6"

CR

COFFEE BAR 620

A11.01

WAR RM 616

1

10' - 7"

SERVICE ELEV.

CLOSET 619

1 2

BREAK RM 614

CR

IT/SERVER 617

1

5

2

7

2

5

OFFICE 604

ALIGN

5

5 DL

B

10' - 2"

9' - 10"

10' - 0"

CONFERENCE 605

9 A12.10

ALIGN

OFFICE 606

OFFICE 607

1 A11.02

2

A3B

A3B

A3B

5

5

5

OFFICE 608

5

OFFICE 609

DL

9 A12.10

A3B

12

A3B

A11.00

19' - 2"

15' - 0"

15

15' - 0"

A3B

A3B OFFICE 603

5

A3B

5

OFFICE 602

19' - 2"

OFFICE 601

A3B

A3B

D2A

6

OFFICE 610

DL

11' - 4 1/2"

8 TYP A12.10

11' - 4"

9' - 0"

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description CONSTRUCTION PLAN

Scale 1/8" = 1'-0" Ref. North

A02.06 CONSTRUCTION PLAN - LEVEL 06 SCALE: 1/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


SHEET NOTES 1 2

3 4 5

PROVIDE POWER FOR SIGNAGE CONF. TABLE TO HAVE 3 SSTL POWER BOXES ON TOP FLUSH W/ SURFACE & 8 BUILT IN MICROPHONES ALL EXIST. P&C RECEPTACLES TO REMAIN IN THIS ROOM. PROVIDE POWER FOR MOTORIZED MECHOSHADES ALONG WINDOW WALL FINAL AV DESIGN TBD BY AV VENDOR

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

TR

MEJ & Associates, Inc. REF.

F

MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

CR STORAGE 613

DN

3

3

ALL P&C EXISTING TO REMAIN

S

E.6

IT/SERVER 617

ELEV. #2

E.11

CR

ELEV. #2

S

WAR RM 616

ELEV. #3

ELEV. #3

D

STORAGE 3 618

CLOSET 619

E.3 E.2

+36

SERVICE ELEV.

+36 CR

S

E.1

E.4 FE

CTV +54+54+54

COPY/FILE 615

COFFEE BAR 620

SS

P V

E.5

E.7

E.8

PF.1 PF.2

CR

PF.3

S

SERVICE ELEV.

+36 +36

BREAK RM 614

S

ELEV. #5 ELEV. #5

MW

ELEV. #1

ELEV. #1

+36 +36

ELEV. #4 ELEV. #4

DR

WORKSTATION 622

V P

OFFICE 612

V P

Issue Date 2 6.13.2012 3 6.18.2012

J

S

Description Issue for Pricing Issue for Permit & Construction

1

OFFICE 611

4

FE

S

S

OFFICE 608

OFFICE 609

OFFICE 610

CTV +54+54 +54 E.10

CTV +54+54 +54

S

S

CTV +54+54 +54

E.12

2

+54+54 +54 CTV

CONFERENCE 605

OFFICE 604

+66 +66 +66 CTV

OFFICE 603

AV

OFFICE 602

OFFICE 607

CTV +54+54 +54

OFFICE 606

S

S

S

S

S

E.10

E.9

OFFICE 601

CTV +54+54 +54

S

5

GENERAL NOTES

E.10

A GC TO CONFIRM ALL CORE LOCATIONS W/ FURN. VENDOR PRIOR TO INSTALL

B

8

7

6.5

5.5

5

4

3

2

1.1

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description POWER & COMMUNICATION PLAN

Scale As indicated Ref. North

A03.06 POWER & COMMUNICATION PLAN - LEVEL 06 SCALE: 1/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


SHEET NOTES 1 2

REMOVE EXISTING LIGHT FIXTURES AND REPLACE WITH FD FIXTURES REMOVE EXISTING CEILING TILE AND GRID & REPLACE WITH CL-2

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

F

CL-2

FD

STORAGE 613

FD

FB3

9' - 0" 1

2

FB3

COPY/FILE 615

CL-2

FD

FB3

COFFEE BAR 620

BREAK RM 614

9' - 0"

IT/SERVER 617

CLOSET 619

FD

CL-2

WAR RM 616

UC

UC

CL-2

FB3

STORAGE 618

FD

CL-2

FD

FD

FD

FD

FD

D

9' - 0" UC

CL-2

9' - 6"

FB3

FE FC2 FB1

FB1

FB1

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

FB4

9' - 6"

FB2 FC1

2 A12.10 FA1

FA1

FA1

FB2

FB3

9' - 6"

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FA1

FA1

FB2

FA1

FA1

FA1

FA1

FA1

FA1

UC

9' - 6"

CL-1

CL-2

9' - 6"

9' - 6"

CL-2

FB1

CL-2

FA1

FA1 FA1

FA1

OFFICE 612

8' - 10"

FA2

FC1

FB3

FB2

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FA1

FB1 FC1

FC1

FC1

8' - 6" FB1

FB1

FB1

FC1

ALIGN

ALIGN FB1

FB1

FB1

FC1

FB2

FB1

FC1

FC1

FC1

8' - 6" FB1

FB1

FB1

FC1

FC1

ALIGN

CL-1 FB1

FB1

FC1

FC1

FB1

FB2

FC1

FC1

FC1

CL-1

ALIGN

FB1

FC1

FB1

9' - 11"

FC1

EQ EQ

FC1

GENERAL NOTES

FB2

FB1

FB1

FC1

FC1

FC1

FC2

OFFICE 611

8' - 6"

FB1

FB2

FC1

FB1

FB2

FB1

FB1

FB2

FB1

FB1

CL-2

Issue Date 2 6.13.2012 3 6.18.2012

Description Issue for Pricing Issue for Permit & Construction

A RE: A00.35 FOR CEILING TYPES B RE: ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE

9' - 6"

FB2

OFFICE 603

FB4

OFFICE 604

FB3

FB3

FB4 FA1

FA1

FA1

9' - 6"

9' - 6"

FA1

9' - 6"

FA1

FA1

9' - 6"

CL-2

FB3

CL-2

FB3

FB3

FB3

FB3

FA1

FA1

FA1

OFFICE 606

FB3

OFFICE 607

OFFICE 608

CL-2

CL-2

FA1

FB3

CL-2

CL-2

CL-3 CONFERENCE 605

FB3

8' - 6"

7

FB3

FB3

FB3

FA2

9' - 6"

FA1

FB3

FA1

FA1

9' - 6"

OFFICE 609

CL-2

FA2 FA1

FA1

9' - 6"

FA2 FA1

FA1

9' - 6"

FB3

FA2 FA1 FA2

OFFICE 610 FA1

FA1

FA1

9' - 6"

CL-1

ALIGN

B

8

FB3

9' - 6"

FB4

FB4

CL-2

8' - 0"

OFFICE 602

EQ

OFFICE 601

EQ

FA1

ALIGN

6.5

5.5

5

4

3

2

1.1

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description REFLECTED CEILING PLAN

Scale As indicated Ref. North

A04.06 REFLECTED CEILING PLAN - LEVEL 06 SCALE: 1/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


SHEET NOTES

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

F DN ELEV. #4 ELEV. #4

ML-1

ELEV. #1

ELEV. #1

1 ELEV. #5 ELEV. #5

ELEV. #2

ML-1

ELEV. #2

ML-1

SP-3

ELEV. #3

ELEV. #3

SERVICE ELEV.

ML-1

SERVICE ELEV.

ML-1 ML-1

ML-1

D

GENERAL NOTES

CPT-1

Issue Date 2 6.13.2012 3 6.18.2012

Description Issue for Pricing Issue for Permit & Construction

A RE: A00.35 FOR FINISH SCHEDULE B ALL WALLS TO BE PAINTED P-1, U.N.O.

WB-1

WB-1

C ALL WALLS TO RECEIVE RB-1, U.N.O. D CL-1 TO BE PAINTED TO MATCH P-1, U.N.O.

CPT-1 SF-1

SF-1

CPT-1

SF-1

SF-1

CPT-1

SP-2

SP-5

1' - 0"

1' - 0" TYP

E ALL CARPET TO BE CP-1

SP-2

SP-2

SP-2

F RE: A12.10 FOR FLOORING TRANSITION AND BASE DETAILS SF-1

SP-2

FE DL

DL

DL

B

8

7

6.5

5.5

5

4

3

2

1.1

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description FINISH PLAN

Scale As indicated Ref. North

A05.06 FINISH PLAN - LEVEL 06 SCALE: 1/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


SHEET NOTES

RELIANCE Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

Gensler 8

7

6.5

5.5

5

4

3

2

1.1

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

F

STORAGE 613

DN ELEV. #4 ELEV. #4

ELEV. #1

ELEV. #1

IT/SERVER 617 ELEV. #5 ELEV. #5

ELEV. #2 ELEV. #2

WAR RM 616

COPY/FILE 615 BREAK RM 614

ELEV. #3

ELEV. #3

SERVICE ELEV. SERVICE ELEV.

STORAGE 618

CLOSET 619

D

Issue Date 2 6.13.2012 3 6.18.2012

FE

WORKSTATION 622

WORKSTATION 624

Description Issue for Pricing Issue for Permit & Construction

OFFICE 612

OFFICE 611

CONFERENCE 605

FE DL

DL

DL

B

OFFICE 601

OFFICE 602

OFFICE 603

OFFICE 604

OFFICE 606

OFFICE 607

OFFICE 608

OFFICE 609

OFFICE 610

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description FURNITURE PLAN

Scale 1/8" = 1'-0" Ref. North

A06.06 FURNITURE PLAN - LEVEL 06 SCALE: 1/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

1

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


GL-1

GL-1

GL-1

GL-1

GL-1

GL-1

GL-1

RELIANCE

P-1 SCHED. DOORS

6"

4"

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

SCHED. DOOR

2 1/2" TYP VERTICAL MULLION

WD-1 ENTRY WALL SYSTEM BY MILLWORKER

6" GL-2 WD-1 OFFICE FRONT SYSTEM BY MILLWORKER

GL-2

FRONT ENTRANCE ELEVATION

13

SCALE: 3/8" = 1'-0"

6"

GL-2

GL-2

GL-2

WD-1 STILE BETWEEN SCHED DOOR

CONFERENCE ROOM ELEVATION @ LOBBY

Gensler

1

SCALE: 3/8" = 1'-0"

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc.

6" TYP

4" TYP

MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

GL-1

5' - 0"

SCHED. DOOR

WD-1

GL-1

3' - 9" DOOR OPENING

2 1/2" TYP. VERTICAL MULLION

SCHED. DOOR

3' - 9" DOOR OPENING

5' - 0"

WD-1

GL-1

SCHED. DOOR

5' - 0"

WD-1 PARTITION END CAP

3' - 9"

WD-1

GL-1

5' - 0"

WD-1 PARTITION END CAP

SCHED. DOOR

3' - 9"

SCHED. DOOR

3' - 9"

GL-1

WD-1

5' - 0"

PARTITION WD-1 END CAP

EXECUTIVE OFFICE ELEVATION

Issue Date 2 6.13.2012 3 6.18.2012

2

4" TYP

SCALE: 3/8" = 1'-0"

WD-1

GL-1

SCHED. DOOR

GL-1

SCHED. DOOR

GL-1

SCHED. DOOR

GL-1

Description Issue for Pricing Issue for Permit & Construction

SCHED. DOOR

SCHED CEILING WALL SYSTEM BY MILLWORKER GL-2

PROVIDE & INSTALL FUTURE BACKING AS REQUIRED

5' - 0"

6" TYP

CONFERENCE RM - CREDENZAL WALL ELEVATION 15 SCALE: 3/8" = 1'-0"

3' - 9" DOOR OPENING

3

SCHED CEILING

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

PROVIDE BLOCKING IN WALL FOR SIGNAGE

1' - 0"

Scale 3/8" = 1'-0"

RE: PLAN

RE: PLAN

VERIFY MOUNTING HTS OF TV & VIDEO CAMERA BEFORE INSTALLATION FOR OPTIMAL A/V

Project Number 25.1098.000

Description INTERIOR ELEVATIONS

CONCEALED FLOURESCENT STRIP UP/DOWNLIGHT

SCHED. BASE 1' - 0"

SCALE: 3/8" = 1'-0"

ST-2

WALL MTD RECESSED VIDEO CAMERA BY OTHERS

1' - 0"

CONFERENCE RM - TV WALL ELEVATION

Project Name Interior Build-Out

ALIGN

SCHED CEILING ST-2 SP-1; CUT & STACKED; SUPPORT FRAME TBD

8' - 6"

5' - 6" CL OF TV MONITOR

ALIGN

COORD. SIZE OF OPENING W/ EQUIPT. MAINTAIN 1" PERIMETER GAP AROUND TV. FLUSH W/ ADJACENT WALL RECESSED SCHED. EQUIPMENT.

Seal/Signature

06.18.2012

SCHED CEILING

GL-2 WALL SYSTEM BY MILLWORKER

3' - 9" DOOR OPENING

SCALE: 3/8" = 1'-0"

EQ

E.9

3' - 9" DOOR OPENING

ASSOCIATE OFFICE WALL ELEVATION

1' - 0"

EQ

3' - 9" DOOR OPENING

8' - 6"

2' - 10"

ALIGN

1' - 0"

ALIGN

FWP-1; ALIGN SEAMS W/ CL-3 ABOVE

A11.00 12

CORE DRILL WALL ELEVATION SCALE: 3/8" = 1'-0"

8

RECEPTION WALL ELEVATION SCALE: 3/8" = 1'-0"

4

© 2012 Gensler


RELIANCE SCHED CEILING SCHED FIXTURE CONCEALED UPPER CAB. SCHED FIXTURE

1' - 6 1/4"

5 EQ

LQ-1 UPPER CABS. EQ

EQ E.3

PF.2

2' - 10"

ST-3 COUNTERTOP

WD-1 FULL DEPTH UPPER CAB.

2' - 0"

ST-3 BACKSPLASH

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

PF.1

CONCEALED DOWN CAB. SCHED. FIXTURE WD-1 COFFEE SURROUND; COORD. OPENING W/ SCHED EQUIPT.

E.2

E.1

2' - 0" TRASH & RECYCLE DRAWERS

COFFEE BAR 3D VIEW

13

SCALE:

COFFEE BAR ELEVATION

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

1

SCALE: 3/8" = 1'-0"

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

6 EQ

COORD. W/ E.4

ALIGN

ALL VISIBLE CABINETRY SURFACES TO BE PL-1, UNO

E.6

PF.3

ALIGN

ALIGN

ALIGN

ALIGN

E.11

ALIGN

ALIGN

2' - 0"

2' - 5"

BUILT IN PLAM MICROWAVE SURROUND W/ BASE CABINET

PL-1 FULL HT BACKSPLASH CO-1 COUNTERTOP E.4

2' - 10"

PF.4 E.3

2' - 0" FIXED PL-1 PANEL

BREAK ROOM - EAST 3D VIEW

14

SCALE:

Issue Date 2 6.13.2012 3 6.18.2012

BREAK ROOM - EAST ELEVATION

Description Issue for Pricing Issue for Permit & Construction

2

SCALE: 3/8" = 1'-0"

SCHED CEILING

P-1

2' - 10"

CO-1 COUNTERTOP

PL-1

8 EQ

Seal/Signature

BREAK ROOM - WEST 3D VIEW

15

SCALE:

BREAK ROOM - WEST ELEVATION

3

SCALE: 3/8" = 1'-0"

SCHED CEILING

06.18.2012

SCHED CEILING

SCHED PARTITION

SCHED. FIXTURE

Project Name Interior Build-Out

SCHED BASE

SCHED BASE

2' - 5" P-1

2' - 0"

COAT ROD P-1

PL-1 UPPERS SCHED FIXTURE P-1 PL-1 COUNTER

PL-1 BASE

5' - 5" 6' - 0"

1' - 3" 1' - 0" 1' - 0" 1' - 0" 1' - 0"

PL-1 SHELVING

2' - 10"

PL-1 SHELF Project Number 25.1098.000

Description INTERIOR ELEVATIONS

Scale 3/8" = 1'-0"

SCHED DOORS

A11.01 CLOSET WALL ELEVATION - OPEN SCALE: 3/8" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

6

CLOSET WALL ELEVATION - CLOSED SCALE: 3/8" = 1'-0"

5

COPY/FILE ROOM ELEVATION SCALE: 3/8" = 1'-0"

4

© 2012 Gensler


SCHED. DOOR

RELIANCE

GL-1

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746 SP-2

P-1

WALL SYSTEM BY MILLWORKER

TYP. EXEC. OFFICE - INTERIOR CHATBOARD WALL ELEVATION

1

SCALE: 3/8" = 1'-0"

Gensler

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

ALIGN

WD-1 SOFFIT FWP-1; PROVIDE & INSTALL PLYWOOD BACKING AS REQ'D WD-1 SHELVING

EQ

EQ

SCHED CEILING

1' - 11 3/4"

SCHED CEILING

EQ

ST-3 COUNTER

2' - 7"

WD-1 BASE CABINETS

4 FILE DRAWERS

TYP. EXEC. WORK WALL ELEVATION SCALE: 3/8" = 1'-0"

SCHED BASE

12' - 0" 3 EQ

PULL OUT DRAWER FOR PRINTER 4 DRAWERS W/ ADJ. SHELVING

2

Issue Date 2 6.13.2012 3 6.18.2012

Description Issue for Pricing Issue for Permit & Construction

Seal/Signature

06.18.2012 Project Name Interior Build-Out

Project Number 25.1098.000

Description INTERIOR ELEVATIONS

Scale 3/8" = 1'-0"

A11.02 © 2012 Gensler

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt


SHEET NOTES 02 41 19.D02 EXISTING SLAB TO REMAIN

RELIANCE

02 41 19.D02 EXISTING SLAB TO REMAIN

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

0' - 6"

09 29 00.G00 CONTINUOUS ACOUS SEALANT 09 22 16.A11 SLIP-TYPE HEAD JOINT 09 22 16.A11 SLIP-TYPE HEAD JOINT

09 29 00.F00 SOUND ATTENUATION BLANKET

09 29 00.F00 SOUND ATTENUATION BLANKET

SCHEDULED CEILING, REFER TO REFLECTED CEILING PLAN 09 29 00.A00 GYPSUM BOARD 09 22 16.A00 METAL STUD

SCHEDULED CEILING, REFER TO REFLECTED CEILING PLAN 09 29 00.A00 GYPSUM BOARD 09 22 16.A00 METAL STUD 09 29 00.A00 GYPSUM BOARD

A3B HEAD CONDITION

2

SCALE: 3" = 1'-0"

Gensler

09 22 16.A00 METAL STUD

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

09 29 00.F00 SOUND ATTENUATION BLANKET MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

VARIES REFER TO PLAN(S)

02 41 19.D01 EXISTING WALL TO REMAIN

09 29 00.A00 GYPSUM BOARD

09 29 00.A00 GYPSUM BOARD

09 29 00.F00 SOUND ATTENUATION BLANKET

09 29 00.F00 SOUND ATTENUATION BLANKET

09 22 16.A00 METAL STUD

09 22 16.A00 METAL STUD

09 22 16.A01 METAL RUNNER TRACK

09 22 16.A01 METAL RUNNER TRACK

09 29 00.G00 CONTINUOUS ACOUS SEALANT 02 41 19.D02 EXISTING SLAB TO REMAIN

09 29 00.G00 CONTINUOUS ACOUS SEALANT 02 41 19.D02 EXISTING SLAB TO REMAIN

PARTITION TYPE D SCALE: 3" = 1'-0"

3 PARTITION TYPE A SCALE: 3" = 1'-0"

Issue Date 2 6.13.2012 3 6.18.2012

1

Description Issue for Pricing Issue for Permit & Construction

PARTITION TYPE NOTES

1A3D Seal/Signature PARTITION TYPE DESIGNATOR STUD DEPTH (SEE STUD DEPTH SCHEDULE BELOW) PARTITION SERIES DESIGNATOR (SEE PARTITION TYPES A12.00-A12.0X) FIRE RATING (WHERE APPLICABLE)

STUD DEPTH SCHEDULE TAG NUMBER DESIGNATOR 0 1 2 3 4 6 8

*

MTL STUD DEPTH 7/8" 1 5/8" 2 1/2" 3 5/8" 4" 6" 8"

MTL C-H STUD DEPTH

WOOD STUD DEPTH

9 5/8" 11 5/8"

2 1/2" 4" 6"

CMU WIDTH

4" 6"

3 5/8" 5 5/8" 7 5/8"

Project Name Interior Build-Out

Project Number 25.1098.000

THE DEPTH DESIGNATIONS 1 AND 2 ARE USED FOR 9.5/8" AND 11.5/8" BLOCKS RESPECTIVELY.

A. PARTITION TYPES ARE NOT SEQUENTIAL. B. ALL GYPSUM BOARD TO BE 5/8" THICK UON. C. REFER TO SHEET A12.01 FOR PARTITION HEAD AND SILL DETAILS. D. ALL PARTITIONS SHALL BE COORDINATED WITH SCHEDULED FINISHES FOR PARTITION LAYOUT AND REQUIRED CLEARANCE. E. PROVIDE 1/2" PLYWOOD SHEET BLOCKING FOR ARTWORK, TYPICAL. FOR EXACT LOCATION AND QUANTITY OF ARTWORK REFER TO ARTWORK CONSULTANT'S DRAWINGS, TBD. F. PROVIDE BLOCKING IN PARTITIONS FOR ALL MILLWORK AS REQUIRED. COORDINATE LOCATIONS AND BLOCKING TYPE WITH MILLWORKER.

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

06.18.2012

Description PARTITION TYPES

Scale As indicated

A12.00 © 2012 Gensler


SHEET NOTES

RELIANCE

EXISTING OR NEW SCHEDULED PARTITION SHEET METAL PROVIDE CONTINUOUS SHEET METAL BACKING BEHIND BASE EXTEND UP BEHIND GYP. BOARD

METAL STUD FRAMING HANGER WIRE

Terrace 7 2801 Via Fortuna Drive Suite 600 Austin, TX 78746

1/4"

SCHED PARTITION ALUMN FLOATABLE END CAP; PAINT TO MATCH PARTITION

ALIGN

CORNER BEAD

1/4"H X1/4"D CONT. REVEAL

REFER TO RCP

FLUSH WOOD BASE SCHEDULED ACOUSTICAL PANEL CEILING

CLOSED CELL COMPRESSIBLE GASKET; GASKET SHALL CREATE CONTINUOUS SEAL

PROVIDE ADDTIONAL BASE FOR FIELD CUT RE: FINISH PLAN FOR COLOR

9/16" WALL ANGLE

EXTRUDED ALUMN. TO ALIGN W/ EXIST. CURTAIN WALL MULLION & SILL LINE OF SILL BELOW

VARIES PER RCP

SHIM AS REQUIRED

CORNER BEAD

SCHED. FLOORING

5/8" GYP. BOARD OVER METAL STUD FRAMING

EXIST. EXTERIOR CURTAIN WALL SYSTEM SCHEDULED PARTITION

ENLARGED PLAN - PARTITION @ CENTER MULLION9 SCALE: 3" = 1'-0"

Gensler

CEILING TRANSITION

5

SCALE: 3" = 1'-0"

BASE - WOOD BASE

1

SCALE: 12" = 1'-0"

212 Lavaca St. Suite 390 Austin TX 78701 Tel: 512.867.8100 Fax: 512.867.8101

MEJ & Associates, Inc. MEP Engineers 811 Barton Springs Rd. Suite 700 Austin TX 78704 Tel: 512.457.8771 Fax: 512.457.8743

9' - 6"

9' - 6" DMPT REGLET SCHED CEILING

SCHED CEILING

EXIST. EXTERIOR WALL 15/16" WALL ANGLE

6"

6"

8' - 6"

SCHED FIXTURE

Issue Date 2 6.13.2012 3 6.18.2012

Description Issue for Pricing Issue for Permit & Construction

SCHED CEILING

CEILING TRANSITIONS

2

SCALE: 3" = 1'-0"

SCHEDULED DOOR WHERE OCCURS ON PLAN RESILIENT FLOORING SCHED DOOR WHERE OCCURS ON PLAN SCHED VINYL FLOORING

SCHLUTER RENO STAINLESS STEEL TRANSITION STRIP PROVIDE 1" UNDERCUT AT RESTROOMS & TOILET. ALL OTHER LOCATIONS 1/4"

ARMSTRONG VINYL REDUCER STRIP, VT0 SHADOW GREY

SCHEDULED TILE, (CT-3)

SCHED CARPET

1/2" MINIMUM SELF LEVELING MORTAR BED AT CERAMIC TILE NOTE: REFER TO A02.01 & A05.01 FOR SCOPE OF RESILIENT FLOOR SPOT FLOATING PREP WORK.

FEATHER TO ALIGN FLOOR FINISH - MAX 1/8" PER FOOT

TRANSITION - VCT TO CARPET AT DOOR SCALE: 6" = 1'-0"

7

LVLG & PATCHING COMPOUND. FEATHER TO ALIGN RESILIENT FLOOR FINISH MAX 1/8" PER FOOT

TRANSITION - RESILIENT FLOOR TO TILE SCALE: 6" = 1'-0"

Seal/Signature

3

06.18.2012 Project Name Interior Build-Out

SCHEDULED TILE SCHLUTER-SCHIENE, SATIN STAINLESS STEEL TRANSITION STRIP, ANCHOR TO SLAB

SCHED. PARTITION

Project Number 25.1098.000

SCHEDULED CARPET

ALUMN FLOATABLE END CAP; PAINT TO MATCH PARTITION

Description INTERIOR DETAILS

CLOSED CELL COMPRESSIBLE GASET; GASKET SHALL CREATE CONTINUOUS SEAL

FEATHER TO ALIGN FLOOR FINISH MAX 1/8" PER FOOT SLOPE

EXIST. EXTERIOR CURTIN WALL SYSTEM. NOTE: NO MECHANICAL FASTENERS PERMITTED INTO MULLION

1/2" MINIMUM SELF LEVELING MORTAR BED

Scale As indicated

DRYWALL MOLDING END CLOSURE.

ENLARGED PLAN - PARTITION AT END MULLION SCALE: 3" = 1'-0" K:\25.1098.000\BIM\Building Model\_User Model Files\Adrianna Hong_25.1098.000_Reliance.rvt

A12.10 8

TRANSITION - TILE TO CARPET SCALE: 6" = 1'-0"

4

NOTE: EVERY SHEETNOTE MAY NOT APPEAR ON THIS PAGE

© 2012 Gensler


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.