the name Mitsubishi is synonymous with excellence Known the world over, Mitsubishi is a trusted global leader associated with a variety of products and services. Founded in 1921, Mitsubishi Electric quickly rose to the forefront of the air conditioning industry - a position we still enjoy today.
Unsurpassed air conditioning from Mitsubishi Electric Air conditioning is an ideal way of controlling the internal environment of any building, large or small. It does not only provide cooling when required, but also heating and often hot water can be supplied from the same system. Providing heating and hot water as part of an integrated air conditioning system is far more efficient than traditional heating methods such as gas and as a result reduced running costs and emissions can be realised. More and more people are experiencing the benefits of comfortable working, living and leisure environments made possible with air conditioning. As market leaders, we pride ourselves in providing high performance, competitive systems with low running costs and emissions.
Environmental Awareness Mitsubishi Electric boasts an explicit commitment to sustainable business practices such as energy and resource efficiency, minimising ecological impacts and reducing greenhouse gas emissions. All of our factories and UK operations are ISO14001 registered, the international standard that ensures that we are fully aware of the environmental impact of all our processes and ensures we have procedures in place to reduce them. However, we have gone far further than any accepted minimum standards. Our ‘Environmental Vision 2021’ provides a vision for a lower emission future that influences all our policy decisions. Our Green Gateway Initiative takes this vision even further as it looks to install behavioural change in our own operations and our wider sphere of influence with contractors, consultants and end users. It looks to highlight the advantages and opportunities provided, by ensuring all of our activities are undertaken with consideration to the environment. We are also proud to be a partner within Sustainable Energy Europe, whose stated aim is to raise awareness of energy use in Europe. The Forest Stewardship Council (FSC) is an international network promoting responsible management of the world's forest. The paper this catalogue is printed on supports the development of responsible forest management worldwide. The wood comes from FSC certified, well managed forests, company controlled sources and/or recycled material.
n www.green-gateway.co.uk
n www.sustenergy.org
n www.mitsubishielectric.com/eco
Page 1
Contents 34
PCA-RP Power Inverter Heat Pump, Ceiling Suspended System
10
MSZ-HC-VA(B) Inverter Heat Pump, Wall Mounted System
34
PCA-RP Standard Inverter Heat Pump, Ceiling Suspended System
10
MSZ-GE-VA Inverter Heat Pump, Wall Mounted System
36
PCA-RP-HAQ Power Inverter Heat Pump, Stainless Steel Ceiling Suspended System
10
MSZ-FD-VA Inverter Heat Pump, Wall Mounted System
36
PCA-RP-HAQ Standard Inverter Heat Pump, Stainless Steel Ceiling Suspended System
12
MFZ-KA-VA Inverter Heat Pump, Floor Mounted System
38
PSA-RP Power Inverter Heat Pump, Floor Standing System
12
MXZ-B/C-VA/YA Multi-Split Inverter Heat Pump
38
PSA-RP Standard Inverter Heat Pump, Floor Standing System
14
Branch Boxes for MXZ-8B-VA/YA Power Multi Inverter Heat Pump
40
PHV DXE Recessed Power Inverter Heat Pump, Air Curtain System
16
Accessories / Optional Extras
40
PHV DXE Free Standing Power Inverter Heat Pump, Air Curtain System
42
PHV NT Chilled Water Heat Pump, Sensible Cooling Wall Mounted System
42
Air Handling Unit Controller
44
Common Multi-Split Combinations
48
Accessories / Optional Extras
56
Y Series (4-6hp) Heat Pump, Outdoor Unit
58
Y Series (8-50hp) Standard Heat Pump, Outdoor Unit
60
Y Series (8-36hp) High COP Heat Pump, Outdoor Unit
60
Y Series (8-20hp) Zubadan Heat Pump, Outdoor Unit
62
Y Series (8-36hp) Replace Multi Heat Pump, Outdoor Unit
64
R2 Series (8-36hp) Standard Heat Recovery, Outdoor Unit
20
PKA-RP Power Inverter Heat Pump, Wall Mounted System
20
PKA-RP Standard Inverter Heat Pump, Wall Mounted System
22
PKA-RP Zubadan Inverter Heat Pump, Wall Mounted System
22
PKA-RP Power Inverter Heat Pump, High SHF Wall Mounted System
24
SEZ-KD Inverter Heat Pump, Ceiling Concealed Ducted System
24
PEAD-RP Power Inverter Heat Pump, Ceiling Concealed Ducted System
26
PEAD-RP Standard Inverter Heat Pump, Ceiling Concealed Ducted System
26
PEAD-RP Zubadan Inverter Heat Pump, Ceiling Concealed Ducted System
28
PEA-RP Power Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
28
PEA-RP Standard Inverter Heat Pump, Large Capacity Ceiling Concealed Ducted System
30
SLZ-KA Inverter Heat Pump, 600x600 4-Way Blow Ceiling Cassette System
66
R2 Series (8-28hp) High COP Heat Recovery, Outdoor Unit
30
PLA-RP Power Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
66
R2 Series (8-12hp) Replace Multi Heat Recovery, Outdoor Unit
32
PLA-RP Standard Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
68
WY Series (8-36hp) Water Cooled Heat Pump, Condensing Unit
32
PLA-RP Zubadan Inverter Heat Pump, 4-Way Blow Ceiling Cassette System
70
WR2 Series (8-24hp) Water Cooled Heat Recovery, Condensing Unit
Page 2
Page 3
Contents 72
PFD-P-VM-E Heat Pump, Close Control System
100
Lossnay VL 100U, Residential Model
74
PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit
100
Lossnay LGH-RSDC-E, DC Model
74
PLFY-P-VCM-E2 600x600 4-Way Blow Ceiling Cassette Indoor Unit
102
Lossnay LGH RX5-E, Commercial Series
76
PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit
102
Accessories / Optional Extras
76
PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit
78
PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit
78
PEFY-P-VMA-E Ceiling Concealed Ducted Indoor Unit
80
PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit
106
Core Products - Remote Controllers
80
PCFY-P-VKM-E Ceiling Suspended Indoor Unit
108
Core Products - Centralised Controllers
82
PKFY-P-VBM/VHM/VKM-E Wall Mounted Indoor Unit
110
Core Products - Interfaces
82
PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit
113
TG2000 Software Packages
84
PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit
113
AG150 Panel and Cover Options
84
PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit
114
AG150/GB50/G50 Software Options - Pin Code Activation
86
PFFY-P-VKM-E Floor Standing Exposed Indoor Unit
117
BEMS Core Products
86
GUF-RD3 Lossnay Outdoor Air Processing Unit
120
Procon M2M
88
PWFY-P VRF Heat Pump Boiler
121
Run Standby Panel
88
VRF PHV NT Chilled Water, Sensible Cooling Wall Mounted Indoor Unit
121
Commissioning
90
VRF PHV DXE Recessed Air Curtain
90
VRF PHV DXE Free Standing Air Curtain
92
BC Controllers / Water System Connection Box
94
Air Handling Unit Controllers
96
Accessories / Optional Extras
Page 4
TM
Page 5
Split-System Product Range Overview Outdoor Units
0.9kW Cooling Capacity M Series Inverter
MUZ-HC25-35VA(B)
44kW Cooling Capacity
M Series Inverter (Multi-Split)
M Series Inverter
M Series Inverter
M Series Inverter Multi-Split
M Series Inverter Multi-Split
M Series Inverter Multi-Split
M Series Power Multi
Mr Slim Standard Inverter
Mr Slim Standard Inverter
Mr Slim Power Inverter
Mr Slim Power Inverter
Mr Slim Power Inverter
MUZ-GE25-35VA MUZ-FD25-35VABH SUZ-KA25/35VA2 MXZ-2C52VA
MUZ-GE50VA SUZ-KA50-60VA2
MUZ-GE60-71VA SUZ-KA71VA2
MXZ-3C54VA MXZ-4C71VA
MXZ-4C80VA MXZ-5C100VA
MXZ-6C120VA
MXZ-8B140VA MXZ-8B160YA
PUHZ-P100V/YHA(3)
PUHZ-P125-250V/YHA(3)
PUHZ-RP35/50VHA4
PUHZ-RP60/71VHA4
PUHZ-RP100-250V/YKA
Indoor Units Model / Size
MSZ-HC-VA(B)
22 (2.2kW)
Multi-Split only
25 (2.5kW)
35 (3.5kW)
50 (5.0kW)
60 (6.0kW)
71 (7.1kW)
100 (10.0kW)
125 (12.5kW)
140 (14.0kW)
200 (19.0kW)
250 (22.0kW)
400 (38.0kW)
Mr Slim Zubadan Inverter
PUHZ-HRP71-125V/YHA2
500 (44.0kW)
MSZ-GE-VA MSZ-FD-VA PKA-RP-HAL/KAL MFZ-KA-VA SEZ-KD-VAQ PEAD-RP-JAQ PEA-RP-GAQ SLZ-KA-VAQ PLA-RP-BA(2)(3) PCA-RP-KAQ PCA-RP-HAQ PSA-RP-GA Page 6
Page 7
The Adaptable Split-System Range
Designed to fit anywhere
M Series
Available in a variety of options, our Split-System range fits in wherever it’s needed. Indoor units can be four way blow cassettes, ducted, wall, floor or ceiling mounted.
Room Air Conditioning
Up to eight indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.
Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to
www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 8
Air Conditioning Commercial Heating Domestic Heating Photovoltaics
Wall Mounted Systems MSZ-HC-VA(B) Classic Inverter Heat Pump Indoor MSZ-HC25VA
Outdoor MUZ-HC25VA
MSZ-HC35VAB MUZ-HC35VAB
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Starting Cooling Current (A) Nominal & UK Outdoor (kW)
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor
Outdoor
(kg)
(kg)
3.2 (0.9-4.4)
2.5 (0.9-3.0) 2.65 (0.75-3.65) 2.5 (0.9-3.0)
166
244
410
1.98
4.2
4.2 / 3.7 [5.5]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
10 / 5
9
25
3.6 (0.9-4.8)
3.4 (1.0-3.7) 3.0 (0.75-4.0) 3.35 (1.0-3.65)
196
280
476
2.58
5.3
4.8 / 5.3 [6.5]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
10 / 5
9
25
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
Indoor (kg)
(kg)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Note: Indoor price includes infra-red remote controller
MSZ-GE-VA Inverter Heat Pump Indoor MSZ-GE22VA MSZ-GE25VA MSZ-GE35VA
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
N/A Multi-Split Only 3.3 (0.9-4.0) MUZ-GE25VA MUZ-GE35VA
3.2 (1.3-4.5) 4.0 (1.6-5.3)
Indoor Outdoor System Price Price Price
Sensible Starting Cooling Current (A) Nominal & UK Outdoor
(£)
(£)
(£)
2.2 (0.9-3.0) 2.75 (0.75-3.3) 2.2 (0.9-3.0)
184
-
-
-
-
-/-
6/-
-
9.52(3/8")
6.35(1/4")
-
10
-
2.65 (1.1-3.75) 2.5 (1.1-3.45)
189
334
523
2.40
3.7
3.7 / 2.9 [7.4]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
10
30
4.6
4.6 / 4.2 [8.6]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
10
33
2.5 (1.1-3.5) 3.5 (1.1-4.0)
3.3 (1.35-4.4) 3.45 (1.1-3.95)
227
379
606
(kW)
2.87
MSZ-GE50VA
MUZ-GE50VA
5.8 (1.4-7.3)
5.0 (1.4-5.5) 4.8 (1.15-6.05) 4.95 (1.4-5.45)
307
485
792
3.80
7.0
7.0 / 6.8 [13]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
30 / 15
10
54
MSZ-GE60VA
MUZ-GE60VA
6.8 (2.0-9.3)
6.0 (1.5-7.5) 5.65 (1.65-7.75) 5.95 (1.5-7.45)
335
522
857
4.74
7.9
7.9 / 7.8 [14.5]
6 / 16
4 Core
15.88(5/8")
6.35(1/4")
30 / 15
16
50
MSZ-GE71VA
MUZ-GE71VA
8.1 (2.2-9.9)
7.1 (2.4-8.7) 6.75 (1.85-8.25) 7.05 (2.4-8.65)
453
680
1133
5.54
9.4
9.4 / 9.3 [16.6]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
30 / 15
16
53
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
Indoor (kg)
(kg)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Note: Indoor price includes infra-red remote controller
MSZ-FD-VA Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Starting Cooling Current (A) Nominal & UK Outdoor (kW)
MSZ-FD25VA
MUZ-FD25VABH 3.2 (1.5-6.3)
2.5 (1.1-3.5) 2.65 (1.25-5.25) 2.5 (1.1-3.45)
233
432
665
2.13
2.9
2.9 / 2.4 [10]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
12
36
MSZ-FD35VA
MUZ-FD35VABH 4.0 (1.3-6.6)
3.5 (0.8-4.0)
274
497
771
2.98
3.9
3.9 / 3.8 [10.5]
6 / 16
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
12
36
3.3 (1.1-5.5)
3.45 (0.8-3.95)
Note: Indoor price includes infra-red remote controller
Page 10
Page 11
Floor Mounted Systems MFZ-KA-VA Inverter Heat Pump Indoor MFZ-KA25VA
Outdoor SUZ-KA25VA2
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
3.4 (0.9-5.1)
2.5 (0.9-3.4) 2.85 (0.75-4.25) 2.5 (0.9-3.35)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
464
474
938
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
3.65
3.85 / 3.25 [8.4]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
6 / 10
4 Core
9.52(3/8")
6 / 20
4 Core
12.7(1/2")
Sensible Starting Cooling Current (A) Nominal & UK Outdoor (kW)
1.65
System Running Current (A) Heating / Cooling
MFZ-KA35VA
SUZ-KA35VA2
4.0 (0.9-6.2)
3.5 (0.9-3.9) 3.3 (0.75-5.15) 3.45 (0.9-3.85)
513
539
1052
2.28
4.75
4.95 / 4.75 [9.4]
MFZ-KA50VA
SUZ-KA50VA2
6.0 (0.9-7.9)
4.8 (0.9-5.4) 5.0 (0.75-6.55) 4.75 (0.9-5.35)
612
606
1218
3.02
6.75
6.55 / 6.95 [16.2]
Starting Current
Running Current
Fuse Rating
Indoor
Outdoor
(kg)
(kg)
20 / 12
14
33
6.35(1/4")
20 / 12
14
37
6.35(1/4")
30 / 15
14
53
Note: Indoor price includes infra-red remote controller
Multi-Split Outdoor Units MXZ-B/C-VA/YA Multi-Split Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
Outdoor Price
(kW)
(kW)
(kW)
(kW)
(£)
(A)
(A) [MAX]
Total Pipe Length
(A)
Interconnecting Cable
(m)
Max Pipe Length per Indoor Unit
Furthest Pipe Length Out to Ind
Max Height Difference Out to Ind
Max Height Difference Ind to Ind
(m)
(m)
(m)
(m)
Outdoor (kg)
2 units
MXZ-2C52VA
6.4 (1.0-7.0)
5.2 (1.1-6.0)
5.3 (0.85-5.8)
5.15 (1.1-5.95)
803
7.22
7.22 [10.2]
16
4 Core
30
20
N/A
15*2
N/A
38
2 - 3 units
MXZ-3C54VA
7.0 (2.6-9.0)
5.4 (2.9-6.8)
5.8 (2.15-7.5)
5.35 (2.9-6.75)
944
6.43
6.43 [15]
25
4 Core
50
25
N/A
15*2
N/A
57
7.49
7.49 [15]
N/A
15*2
N/A
58
2 - 4 units
MXZ-4C71VA
8.6 (3.4-10.7)
7.1 (3.7-8.8)
7.15 (2.85-8.9)
7.05 (3.65-8.75)
1432
25
4 Core
60
25
2 - 4 units
MXZ-4C80VA
9.4 (3.4-11.6)
8.0 (3.7-9.2)
7.8 (2.85-9.65)
7.95 (3.65-9.15)
1740
8.59
8.59 [17.4]
25
4 Core
70
25
N/A
15*2
N/A
67
2 - 5 units
MXZ-5C100VA
12.0 (4.1-14.0)
10.0 (3.9-11.0)
9.95 (3.4-11.65)
9.9 (3.85-10.9)
1947
12.45
12.45 [18.4]
25
4 Core
80
25
N/A
15*2
N/A
68
2 - 6 units
MXZ-6C120VA
14.0 (3.5-16.5)
12.0 (3.5-13.5)
11.65 (2.9-13.7)
11.9 (3.45-13.4)
2538
15.85
15.85 [27]
40
4 Core
80
25
N/A
15*2
N/A
88
14
17.05 [29.5]
115
15*1
70
30*3
12
129
7
7.00 [13]
115
15*1
70
30*3
12
139
2 - 8 units 2 - 8 units
MXZ-8B140VA MXZ-8B160YA
16.0 18.0
14.0 15.5
13.3 14.95
13.9 15.4
2563 3211
40 25
4 Core 4 Core
Note: For indoor unit selection please consult the product catalogue *1 From Branch Box *2 10 if outdoor higher than indoor *3 20 if outdoor lower than indoor
Page 12
Page 13
Branch Boxes for MXZ-8B140VA / MXZ-8B160YA Model Reference
Number of Connectable Indoor Units
Power Supply to Branch Box
Power Supply to Indoor Units
PAC-AK31BC
1-3
From Outdoor Unit
From Branch Box
PAC-AK52BC
1-5
From Outdoor Unit
From Branch Box
Page 14
Dimensions WxDxH
(£)
Pipe Size mm (in) Main Outdoor Side Gas
Pipe Size mm (in) Main Outdoor Side Liquid
Max Pipe Length Outdoor to Branch Box (m)
Total Pipe Length Branch Boxes to Indoor (m)
450x280x198
324
15.88(5/8”)
9.52(3/8”)
55
60
30
15
450x280x198
387
15.88(5/8”)
9.52(3/8”)
55
60
30
15
(mm)
Price
Max Height Difference Max Height Difference Outdoor to Branch Box Branch Box (m) to Indoor (m)
Page 15
Accessories / Optional Extras Description
Model Ref.
Catechin Filter For MSZ-HC25/35VA(B) (10 pack)
MAC-3003CF
Anti-Allergy Enzyme Filters For MSZ-GE22-50VA (10 pack) For MSZ-GE60/71VA (10 pack) For MFZ-KA25-50VA (10 pack)
MAC-408FT-E MAC-2310FT-E MAC-415FT-E
Wired Remote Controller For MSZ-GE22-71VA, MSZ-FD25/35VA & MFZ-KA25-50VA
PAR-30MAA
70
Interfaces For connection to M-NET System For Contact Terminal and PAR-30MAA Wired Remote Controller
MAC-399IF MAC-397IF
113 51
Air Outlet Guides For MXZ-2C52VA, MUZ-HC, MUZ-GE & MUZ-FD For MXZ-3C54VA, MXZ-4C71VA, MXZ-4C80VA & MXZ-5C100VA For MXZ-8B140VA, MXZ-8B160YA
MAC-889SG MAC-856SG PAC-SG59SG-E
101 109 40
Power Multi MXZ-8B Connection Pipe
PAC-AK52YP-E
70
Page 16
Price (ÂŁ) 55
77 233 90
Page 17
The Adaptable Mr Slim Range
Designed to fit anywhere
Mr Slim
Available in a variety of options, the Mr Slim range fits in wherever it’s needed. Indoor units can be four way blow cassettes, ducted, floor, wall or ceiling mounted.
Packaged Split-System Air Conditioning
Up to four indoor units can then be connected to a single outdoor unit providing the ideal air conditioning solution.
Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk
Air Conditioning Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 18
Domestic Heating
Commercial Heating Photovoltaics
Wall Mounted Systems PKA-RP Power Inverter Heat Pump Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PKA-RP35HAL PUHZ-RP35VHA4
4.1 (1.6-5.2)
3.6 (1.6-4.5)
PKA-RP50HAL PUHZ-RP50VHA4
5.0 (2.5-7.3)
Indoor
Outdoor
Sensible Power Cooling Supply Nominal & UK Phase
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
(kg)
(kg)
50 / 30
13
42
6.35(1/4")
50 / 30
13
42
(£)
(£)
(£)
3.5 (1.35-4.4) 3.3 (1.45-4.15)
464
800
1264
2.92
1
5
5.33 / 4.66 [13.4]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
4.6 (2.3-5.6) 4.25 (2.15-6.2) 4.25 (2.1-5.15)
532
962
1494
3.31
1
5
6.45 / 6.68 [13.4]
6 / 16
4 Core
12.7(1/2")
(kW)
Indoor Outdoor
6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.5 (2.5-6.15)
550
1048
1598
5.16
1
5
8.09 / 7.11 [19.4]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
21
67
6.8 (3.0-8.65) 6.55 (3.05-7.45)
595
1092
1687
5.54
1
5
9.75 / 8.99 [19.4]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
21
67
PUHZ-RP100VKA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
675
1322
1997
7.30
1
5
14.15 / 13.25 [27.1]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
21
116
675
1429
2104
7.30
3
5
5.32 / 5.01 [8.6]
6 / 10
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
21
124
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
PKA-RP60KAL PUHZ-RP60VHA4
7.0 (2.8-8.2)
PKA-RP71KAL PUHZ-RP71VHA4 8.0 (3.5-10.2) PKA-RP100KAL
Indoor Outdoor System Price Price Price
7.1 (3.3-8.1)
3 Phase System PKA-RP100KAL
PUHZ-RP100YKA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
Note: Indoor price includes infra-red remote controller
PKA-RP Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PKA-RP100KAL PUHZ-P100VHA3 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase
Starting Current (A) Outdoor
(£)
(£)
(£)
675
1085
1760
7.05
1
8
14.81 / 14.15 [28.6]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
675
1207
1882
7.05
3
3
5.65 / 5.06 [13.6]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
(kW)
Indoor Outdoor (kg)
(kg)
50 / 30
21
75
50 / 30
21
77
3 Phase System PKA-RP100KAL
PUHZ-P100YHA 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
Note: Indoor price includes infra-red remote controller
Page 20
Page 21
PKA-RP Zubadan Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PKA-RP100KAL PUHZ-HRP100VHA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 11.1 (4.45-13.85) 9.2 (4.5-10.5)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
(kg)
75 / 30
21
120
75 / 30
21
134
(£)
(£)
675
1845
2520
7.30
1
14
14.15 / 13.39 [35.6]
6 / 40
4 Core
15.88(5/8")
9.52(3/8")
675
1974
2649
7.30
3
3
5.32 / 5.06 [13.6]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
Starting Current (A) Outdoor
Max System Running Current (A)
Fuse Rating (A) Indoor / Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas
Liquid
Max Pipe Length / Height (m)
5
19.6
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
(kW)
Indoor Outdoor (kg)
(£)
3 Phase System PKA-RP100KAL PUHZ-HRP100YHA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 11.1 (4.45-13.85) 9.2 (4.5-10.5) Note: Indoor price includes infra-red remote controller
PKA-RP Power Inverter Heat Pump (High SHF) Indoor PKA-RP100KAL
Outdoor PUHZ-RP60VHA4
Cooling (kW)
6.0
Sensible Cooling*1
Sensible Cooling*2
(kW)
(kW)
(£)
(£)
(£)
Power Supply Phase
5.64
5.76
675
1048
1723
1
Indoor Outdoor System Price Price Price
Indoor Outdoor (kg)
(kg)
21
67
Note: Indoor price includes infra-red remote controller *1 35ºC outdoor / 27ºC DB indoor, 47% relative humidity *2 35ºC outdoor / 24ºC DB indoor, 45% relative humidity
Page 22
Page 23
Ceiling Concealed Ducted Systems SEZ-KD Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor Outdoor (kg)
(kg)
SEZ-KD25VAQ
SUZ-KA25VA2
3.0 (0.9-4.5)
2.5 (0.9-3.2)
2.5 (0.75-3.75) 2.5 (0.9-3.15)
333
474
807
2.00
1
3.65
4.05 / 3.45 [8.6]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
18
33
SEZ-KD35VAQ
SUZ-KA35VA2
4.2 (0.9-5.0)
3.7 (1.0-3.9)
3.5 (0.75-4.15) 3.65 (1.0-3.85)
352
539
891
2.89
1
4.75
5.25 / 5.05 [9.7]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
21
37
SEZ-KD50VAQ
SUZ-KA50VA2
6.4 (1.1-7.2)
5.1 (1.1-5.6)
5.3 (0.9-6.0) 5.05 (1.1-5.55)
431
606
1037
3.88
1
6.75
7.05 / 7.45 [16.7]
6 / 20
4 Core
12.7(1/2")
6.35(1/4")
30 / 30
23
53
SEZ-KD60VAQ
SUZ-KA60VA2
7.4 (0.9-8.0)
5.6 (1.1-6.3) 6.15 (0.75-6.65) 5.55 (1.1-6.25)
477
648
1125
4.42
1
9.75
10.45 / 9.05 [16.7]
6 / 20
4 Core
15.88(5/8")
6.35(1/4")
30 / 30
27
53
8.89
9.85 / 9.75 [17.0]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
30 / 30
27
53
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
SEZ-KD71VAQ
SUZ-KA71VA2
8.1 (0.9-10.4) 7.1 (0.9-8.3) 6.75 (0.75-8.65) 7.05 (0.9-8.25)
533
725
1258
5.25
1
Note: Indoor price includes separate PAR-30MAA wired remote controller
PEAD-RP Power Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Indoor Outdoor (kg)
(kg)
PEAD-RP35JAQ PUHZ-RP35VHA4 4.1 (1.6-5.2)
3.6 (1.6-4.5)
3.5 (1.35-4.4) 3.3 (1.45-4.15)
479
800
1279
3.06
1
5
5.15 / 4.81 [14.1]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
50 / 30
26
42
PEAD-RP50JAQ PUHZ-RP50VHA4 6.0 (2.5-7.3)
5.0 (2.3-5.6)
5.1 (2.15-6.2) 4.6 (2.1-5.15)
545
962
1507
4.20
1
5
7.38 / 7.35 [14.4]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
50 / 30
28
42
PEAD-RP60JAQ PUHZ-RP60VHA4 7.0 (2.8-8.2)
6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.5 (2.5-6.15)
PEAD-RP71JAQ PUHZ-RP71VHA4 8.0 (3.5-10.2) 7.1 (3.3-8.1)
6.8 (3.0-8.65) 6.55 (3.05-7.45)
582
1048
1630
4.98
1
5
8.29 / 7.63 [20.6]
6 / 25
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
33
67
647
1092
1739
5.89
1
5
9.46 / 9.62 [21]
6 / 25
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
33
67
PEAD-RP100JAQ
PUHZ-RP100VKA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
727
1322
2049
8.20
1
5
12.73 / 12.98 [29.2]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
41
116
PEAD-RP125JAQ
PUHZ-RP125VKA 14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.5 (5.05-12.9)
748
1516
2264
10.50
1
5
16.45 / 18.09 [29.3]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
43
116
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
47
118
PEAD-RP140JAQ
PUHZ-RP140VKA 16.0 (5.7-18.0) 14.0 (6.2-15.3) 13.6 (4.85-15.3) 12.9 (5.7-14.1)
799
1821
2620
11.62
1
5
18.94 / 20.39 [30.8]
3 Phase Systems PEAD-RP100JAQ
PUHZ-RP100YKA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
727
1429
2156
8.20
3
5
5.48 / 5.63 [10.7]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
41
124
PEAD-RP125JAQ
PUHZ-RP125YKA 14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.5 (5.05-12.9)
748
1634
2382
10.50
3
5
7.25 / 7.89 [12.3]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
43
126
5
8.25 / 8.83 [13.8]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
47
132
PEAD-RP140JAQ
PUHZ-RP140YKA 16.0 (5.7-18.0) 14.0 (6.2-15.3) 13.6 (4.85-15.3) 12.9 (5.7-14.1)
799
1970
2769
11.62
3
Note: Indoor price includes separate PAR-30MAA wired remote controller
Page 24
Page 25
PEAD-RP Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor Outdoor (kg)
(kg)
PEAD-RP35JAQ
SUZ-KA35VA2
4.1 (0.9-5.0)
3.6 (1.0-3.9)
3.4 (0.75-4.15) 3.55 (1.0-3.85)
479
539
1018
3.06
1
4.75
5.82 / 5.62 [10.3]
6 / 16
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
26
37
PEAD-RP50JAQ
SUZ-KA50VA2
5.9 (0.9-7.2)
4.9 (1.1-5.6)
4.9 (0.75-6.0) 4.85 (1.1-5.55)
545
606
1151
4.17
1
6.75
7.74 / 8.14 [17.4]
6 / 20
4 Core
12.7(1/2")
6.35(1/4")
30 / 30
28
53
PEAD-RP60JAQ
SUZ-KA60VA2
7.0 (0.9-8.0)
5.7 (1.1-6.3)
5.8 (0.75-6.65) 5.65 (1.1-6.25)
582
648
1230
4.90
1
9.75
11.37 / 9.97 [17.6]
6 / 20
4 Core
15.88(5/8")
6.35(1/4")
30 / 30
33
53
PEAD-RP71JAQ
SUZ-KA71VA2
8.0 (0.9-10.2) 7.1 (0.9-8.1)
6.65 (0.75-8.5) 7.05 (0.9-8.05)
647
725
1372
5.89
1
8.89
10.92 / 10.82 [18.1]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
30 / 30
33
53
PEAD-RP100JAQ
PUHZ-P100VHA3 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
727
1085
1812
7.99
1
8
16.18 / 15.38 [30.7]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
41
75
PEAD-RP125JAQ
PUHZ-P125VHA3 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
748
1242
1990
10.46
1
11
19.49 / 20.59 [30.8]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
43
99
6 / 40
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
47
99
PEAD-RP140JAQ
PUHZ-P140VHA3 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.5 (5.05-13.8)
799
1507
2306
11.42
1
11
23.23 / 24.38 [32.3]
3 Phase System PEAD-RP100JAQ
PUHZ-P100YHA
11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
727
1207
1934
7.99
3
3
5.12 / 5.03 [15.7]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
41
77
PEAD-RP125JAQ
PUHZ-P125YHA
14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
748
1405
2153
10.46
3
4
6.29 / 6.85 [15.8]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
43
101
PEAD-RP140JAQ
PUHZ-P140YHA
16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.5 (5.05-13.8)
799
1671
2470
11.42
3
4
7.19 / 7.34 [15.8]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
47
101
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
14
10.99 / 10.15 [31.5]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
14.43 / 14.28 [37.7]
6 / 40
4 Core
15.88(5/8")
6 / 25
4 Core
15.88(5/8")
Note: Indoor price includes separate PAR-30MAA wired remote controller
PEAD-RP Zubadan Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PEAD-RP71JAQ PUHZ-HRP71VHA2 8.0 (3.5-10.2) 7.1 (3.3-8.1)
7.9 (3.45-10.1) 6.55 (3.05-7.45)
PEAD-RP100JAQ PUHZ-HRP100VHA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 11.1(4.45-13.85) 9.2 (4.5-10.5)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
647
1773
2420
727
1845
2572
3 Phase Systems
Sensible Power Cooling Supply Nominal & UK Phase (kW)
5.89
1
Starting Current (A) Outdoor
8.20
1
14
4.98
1
5
Indoor Outdoor (kg)
(kg)
75 / 30
33
120
9.52(3/8")
75 / 30
41
120
9.52(3/8")
50 / 30
33
67
PEAD-RP100JAQ PUHZ-HRP100YHA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 11.1(4.45-13.85) 9.2 (4.5-10.5)
727
1974
2701
8.20
3
3
6.07 / 6.09 [15.7]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
41
134
PEAD-RP125JAQ PUHZ-HRP125YHA2 14.0 (5.0-16.0) 12.5 (5.5-14.0) 13.85 (4.95-15.85) 11.5 (5.05-12.9)
748
2299
3047
10.50
3
3
7.84 / 7.94 [15.8]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
43
134
Note: Indoor price includes separate PAR-30MAA wired remote controller
Page 26
Page 27
Large Capacity Ceiling Concealed Ducted Systems PEA-RP Power Inverter Heat Pump Indoor
Outdoor
PEA-RP200GAQ PUHZ-RP200YKA
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
22.4 (9.5-25.0)
19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.5 (8.3-20.6)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
1140
2870
4010
Sensible Power Cooling Supply Nominal & UK Phase (kW)
15.39
3
Running Current (A) Starting Current (A) Indoor / Outdoor [MAX] Outdoor
5
2.0 / 8.94 [19]
Fuse Rating (A) Indoor / Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas
Liquid
Max Pipe Length / Height (m)
6 / 20
3 Core
28.58(1 1/8")
9.52(3/8")
120 / 30
Indoor Outdoor (kg)
(kg)
70
135
27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 20.25 (10.3-25.75)
1300
3058
4358
18.92
3
5
2.3 / 11.23 [21]
6 / 25
3 Core
28.58(1 1/8")
12.7(1/2")
120 / 30
77
141
PEA-RP400GAQ PUHZ-RP200YKAx2 44.8 (18.0-50.0) 38.0 (18.0-44.8) 38.1 (15.3-42.5) 34.95 (16.55-41.2)
1895
5740
7635
28.50
3
5
3.8 / 8.94 [19]
10 / 20
3 Core
28.58(1 1/8")
9.52(3/8")
120 / 30
130
135
PEA-RP500GAQ PUHZ-RP250YKAx2 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5)
2250
6116
8366
33.88
3
5
5.4 / 11.23 [21]
10 / 25
3 Core
28.58(1 1/8")
12.7(1/2")
120 / 30
133
141
Fuse Rating (A) Indoor / Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas
Liquid
Max Pipe Length / Height (m)
PEA-RP250GAQ PUHZ-RP250YKA
Note: Indoor price includes separate PAR-30MAA wired remote controller
PEA-RP Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PEA-RP200GAQ PUHZ-P200YHA3
22.4 (9.5-25.0)
PEA-RP250GAQ PUHZ-P250YHA3
27.0 (12.5-31.5) 22.0 (11.2-28.0) 22.95 (10.65-26.8) 20.25 (10.3-25.75)
19.0 (9.0-22.4) 19.05 (8.1-21.25) 17.5 (8.3-20.6)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase
Running Current (A) Starting Current (A) Indoor / Outdoor [MAX] Outdoor
(kg)
70 / 30
70
126
12.7(1/2")
70 / 30
77
135
28.58(1 1/8")
9.52(3/8")
70 / 30
130
126
28.58(1 1/8")
12.7(1/2")
70 / 30
133
135
(£)
(£)
1140
2236
3376
15.39
3
5
2.0 / 9.88 [19]
6 / 20
3 Core
28.58(1 1/8")
9.52(3/8")
1300
2456
3756
18.92
3
5
2.3 / 12.0 [21]
6 / 25
3 Core
28.58(1 1/8")
10 / 20
3 Core
10 / 25
3 Core
(kW)
PEA-RP400GAQ PUHZ-P200YHA3x2 44.8 (19.0-50.0) 38.0 (18.0-44.8) 38.1 (16.15-42.5) 34.95 (16.55-41.2)
1895
4472
6367
28.50
3
5
3.8 / 9.88 [19]
PEA-RP500GAQ PUHZ-P250YHA3x2 54.0 (25.0-63.0) 44.0 (22.4-56.0) 45.9 (21.25-53.55) 40.5 (20.6-51.5)
2250
4912
7162
33.88
3
5
5.4 / 12.0 [21]
Indoor Outdoor (kg)
(£)
Note: Indoor price includes separate PAR-30MAA wired remote controller
Page 28
Page 29
4-Way Blow Ceiling Cassette Systems (600x600) SLZ-KA Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor Outdoor (kg)
(kg)
SLZ-KA25VAQ
SUZ-KA25VA2
3.2 (0.9-4.5)
2.5 (0.9-3.2) 2.65 (0.75-3.75) 2.5 (0.9-3.15)
428
474
902
2.15
1
3.65
4.05 / 3.45 [8.5]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
17 [3]
33
SLZ-KA35VAQ
SUZ-KA35VA2
4.0 (0.9-5.0)
3.5 (1.0-3.9)
3.3 (0.75-4.15) 3.45 (1.0-3.85)
483
539
1022
2.70
1
4.75
5.15 / 4.95 [9.6]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
17 [3]
37
SLZ-KA50VAQ
SUZ-KA50VA2
5.0 (0.9-6.5)
4.6 (1.1-5.2)
4.15 (0.75-5.4) 4.55 (1.1-5.15)
576
606
1182
3.13
1
6.75
7.05 / 7.45 [16.7]
6 / 20
4 Core
12.7(1/2")
6.35(1/4")
30 / 30
17 [3]
53
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
Note: Indoor price includes separate SLP-2AAW grille & PAR-30MAA wired remote controller
4-Way Blow Ceiling Cassette Systems PLA-RP Power Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Indoor Outdoor (kg)
(kg)
PLA-RP35BA
PUHZ-RP35VHA4 4.1 (1.6-5.2)
3.6 (1.6-4.5) 3.5 (1.35-4.4) 3.3 (1.45-4.15)
509
800
1309
3.02
1
5
5.15 / 4.98 [13.2]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
50 / 30
22[6]
42
PLA-RP50BA
PUHZ-RP50VHA4 6.0 (2.5-7.3)
5.0 (2.3-5.6) 5.1 (2.15-6.2) 4.6 (2.1-5.15)
578
962
1540
4.05
1
5
7.62 / 7.08 [13.4]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
50 / 30
22[6]
42
PLA-RP60BA
PUHZ-RP60VHA4 7.0 (2.8-8.2)
PLA-RP71BA2 PUHZ-RP71VHA4 8.0 (3.5-10.2)
6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.5 (2.5-6.15)
615
1048
1663
4.56
1
5
8.34 / 7.31 [19.4]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
23[6]
67
7.1 (3.3-8.1) 6.8 (3.0-8.65) 6.55 (3.0-7.45)
683
1092
1775
5.18
1
5
8.76 / 8.71 [19.5]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
23[6]
67
PLA-RP100BA3
PUHZ-RP100VKA
11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
787
1322
2109
7.40
1
5
11.26 / 11.04 [27.5]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
26[6]
116
PLA-RP125BA2
PUHZ-RP125VKA
14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.5 (5.05-12.9)
781
1516
2297
8.88
1
5
16.02 / 16.73 [27.5]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
27[6]
116
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
27[6]
118
PLA-RP140BA2
PUHZ-RP140VKA
16.0 (5.7-18.0) 14.0 (6.2-15.3) 13.6 (4.85-15.3) 12.9 (5.7-14.1)
841
1821
2662
9.94
1
5
19.76 / 19.90 [29.1]
3 Phase Systems PLA-RP100BA3
PUHZ-RP100YKA
11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
787
1429
2216
7.40
3
5
4.59 / 4.51 [9]
6 / 10
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
26[6]
124
PLA-RP125BA2
PUHZ-RP125YKA
14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.5 (5.05-12.9)
781
1634
2415
8.88
3
5
6.26 / 6.51 [10.5]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
27[6]
126
5
7.61 / 7.66 [12.1]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
27[6]
132
PLA-RP140BA2
PUHZ-RP140YKA
16.0 (5.7-18.0) 14.0 (6.2-15.3) 13.6 (4.85-15.3) 12.9 (5.7-14.1)
841
1970
2811
9.94
3
Note: Indoor price includes separate PLP-6BA grille & PAR-30MAA wired remote controller
Page 30
Page 31
PLA-RP Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor Outdoor (kg)
(kg)
PLA-RP35BA
SUZ-KA35VA2
4.1 (0.9-5.0)
3.6 (1.0-3.9) 3.4 (0.75-4.15) 3.55 (1.0-3.85)
509
539
1048
3.02
1
4.75
4.97 / 4.77 [9.4]
6 / 10
4 Core
9.52(3/8")
6.35(1/4")
20 / 12
22[6]
37
PLA-RP50BA
SUZ-KA50VA2
6.0 (0.9-7.2)
5.5 (1.1-5.6) 5.0 (0.75-6.0) 5.45 (1.1-5.55)
578
606
1184
4.46
1
6.75
6.71 / 7.11 [16.4]
6 / 20
4 Core
12.7(1/2")
6.35(1/4")
30 / 30
22[6]
53
PLA-RP60BA
SUZ-KA60VA2
6.9 (0.9-8.0)
6.1 (1.1-6.3) 5.75 (0.75-6.65) 6.05 (1.1-6.25)
615
648
1263
4.64
1
9.75
10.11 / 8.71 [16.4]
6 / 20
4 Core
15.88(5/8")
6.35(1/4")
30 / 30
23[6]
53
683
725
1408
5.18
1
8.89
9.46 / 9.36 [16.6]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
30 / 30
23[6]
53
9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
760
1085
1845
6.96
1
8
14.92 / 14.16 [28.9]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
25[6]
75
PLA-RP125BA PUHZ-P125VHA3 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
781
1242
2023
8.73
1
11
18.23 / 18.48 [29]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
25[6]
99
PLA-RP140BA2 PUHZ-P140VHA3 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.5 (5.05-13.8)
841
1507
2348
9.66
1
11
22.50 / 23.71 [30.6]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
27[6]
99
9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
760
1207
1967
6.96
3
3
5.34 / 5.09 [13.9]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
25[6]
77
PLA-RP125BA PUHZ-P125YHA
14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
781
1405
2186
8.73
3
4
6.54 / 6.51 [14]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
25[6]
101
PLA-RP140BA2 PUHZ-P140YHA
16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.5 (5.05-13.8)
841
1671
2512
9.66
3
4
7.91 / 8.28 [14.1]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
27[6]
101
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
14
8.76 / 8.89 [30]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
PLA-RP71BA
SUZ-KA71VA2
8.0 (0.9-10.2) 7.1 (0.9-8.1) 6.65 (0.75-8.5) 7.05 (0.9-8.05)
PLA-RP100BA PUHZ-P100VHA3 11.2 (4.5-12.5)
3 Phase System PLA-RP100BA
PUHZ-P100YHA
11.2 (4.5-12.5)
Note: Indoor price includes separate PLP-6BA grille & PAR-30MAA wired remote controller
PLA-RP Zubadan Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PLA-RP71BA2 PUHZ-HRP71VHA2 8.0 (4.5-10.2) 7.1 (4.9-8.1) 7.9 (4.45-10.1) 6.55 (4.5-7.45) PLA-RP100BA3 PUHZ-HRP100VHA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 11.1 (4.45-13.85) 9.2 (4.5-10.5) 3 Phase Systems PLA-RP60BA
6.9 (0.9-8.0)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
683
1773
2456
787
1845
2632
5.7 (1.1-6.3) 5.75 (0.75-6.65) 5.65 (1.1-6.25)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
5.18
1
Starting Current (A) Outdoor
Indoor Outdoor (kg)
(kg)
75 / 30
23[6]
120
7.40
1
14
11.76 / 11.26 [36]
6 / 40
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
26[6]
120
4.33
1
9.75
10.11 / 8.71 [16.4]
6 / 20
4 Core
15.88(5/8")
6.35(1/4")
30 / 30
23[6]
53
PLA-RP100BA3 PUHZ-HRP100YHA2 11.2 (4.5-14.0) 10.0 (4.9-11.4) 11.1 (4.45-13.85) 9.2 (4.5-10.5)
787
1974
2761
7.40
3
3
4.86 / 4.69 [14]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
26[6]
134
PLA-RP125BA2 PUHZ-HRP125YHA2 14.0 (5.0-16.0) 12.5 (5.5-14.0) 13.85 (4.95-15.85)11.5 (5.05-12.9)
781
2299
3080
8.88
3
3
6.37 / 6.70 [14]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
27[6]
134
Note: Indoor price includes separate PLP-6BA grille & PAR-30MAA wired remote controller
Page 32
Page 33
Ceiling Suspended Systems PCA-RP Power Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
[MAX]
Fuse Rating (A) Indoor / Outdoor
Interconnecting Cable
System Running Current (A) Heating / Cooling
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas
Liquid
Max Pipe Length / Height (m)
Indoor Outdoor (kg)
(kg)
PCA-RP50KAQ
PUHZ-RP50VHA4
5.5 (2.5-6.6)
5.0 (2.3-5.6) 4.7 (2.15-5.6) 4.6 (2.1-5.15)
629
962
1591
3.95
1
5
6.96 / 7.14 [13.4]
6 / 16
4 Core
12.7(1/2")
6.35(1/4")
50 / 30
25
42
PCA-RP60KAQ
PUHZ-RP60VHA4
7.0 (2.8-8.2)
6.0 (2.7-6.7) 5.95 (2.4-6.95) 5.5 (2.5-6.15)
657
1048
1705
4.86
1
5
8.82 / 6.84 [19.4]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
32
67
PCA-RP71KAQ
PUHZ-RP71VHA4
8.0 (3.5-10.2) 7.1 (3.3-8.1) 6.8 (3.0-8.65) 6.55 (3.05-7.45)
708
1092
1800
5.40
1
5
10.06 / 8.94 [19.4]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
32
67
PCA-RP100KAQ
PUHZ-RP100VKA
11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9)
803
1322
2125
7.70
1
5
13.78 / 12.04 [27.2]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
36
116
9.2 (4.5-10.5)
PCA-RP125KAQ
PUHZ-RP125VKA
14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.5 (5.05-12.9)
846
1516
2362
9.00
1
5
17.66 / 17.66 [27.3]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
38
116
PCA-RP140KAQ
PUHZ-RP140VKA
16.0 (5.7-18.0) 14.0 (6.2-15.3) 13.6 (4.85-15.3) 12.9 (5.7-14.1)
905
1821
2726
9.94
1
5
20.13 / 19.82 [28.9]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
39
118
11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9)
803
1429
2232
7.70
3
5
5.25 / 4.63 [8.7]
6 / 10
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
36
124
3 Phase Systems PCA-RP100KAQ
PUHZ-RP100YKA
9.2 (4.5-10.5)
PCA-RP125KAQ
PUHZ-RP125YKA
14.0 (5.0-16.0) 12.5 (5.5-14.0) 11.9 (4.25-13.6) 11.5 (5.05-12.9)
846
1634
2480
9.00
3
5
6.67 / 6.67 [10.3]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
38
126
PCA-RP140KAQ
PUHZ-RP140YKA
16.0 (5.7-18.0) 14.0 (6.2-15.3) 13.6 (4.85-15.3) 12.9 (5.7-14.1)
905
1970
2875
9.94
3
5
7.63 / 7.52 [11.9]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
39
132
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
Note: Indoor price includes separate PAR-30MAA wired remote controller
PCA-RP Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Sensible Power Cooling Supply Nominal & UK Phase (kW)
Starting Current (A) Outdoor
Indoor Outdoor (kg)
(kg)
PCA-RP50KAQ
SUZ-KA50VA2
5.5 (0.9-6.6)
5.0 (1.1-5.6) 4.55 (0.75-5.5) 4.95 (1.1-5.55)
629
606
1235
3.95
1
6.75
6.72 / 7.12 [16.4]
6 / 20
4 Core
12.7(1/2")
6.35(1/4")
30 / 30
25
53
PCA-RP60KAQ
SUZ-KA60VA2
6.9 (0.9-8.0)
5.7 (1.1-6.3) 5.75 (0.75-6.65) 5.65 (1.1-6.25)
657
648
1305
4.62
1
9.75
10.14 / 8.74 [16.4]
6 / 20
4 Core
15.88(5/8")
6.35(1/4")
30 / 30
32
53
PCA-RP71KAQ
SUZ-KA71VA2
7.9 (0.9-10.2)
7.1 (0.9-8.1) 6.55 (0.75-8.5) 7.05 (0.9-8.05)
708
725
1433
5.40
1
8.89
9.37 / 9.27 [16.5]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
30 / 30
32
53
PCA-RP100KAQ PUHZ-P100VHA3 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
803
1085
1888
7.24
1
8
15.73 / 14.09 [28.7]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
36
75
PCA-RP125KAQ PUHZ-P125VHA3 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
846
1242
2088
8.86
1
11
18.55 / 18.42 [28.8]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
38
99
PCA-RP140KAQ PUHZ-P140VHA3 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.5 (5.05-13.8)
905
1507
2412
9.66
1
11
21.09 / 21.97 [30.4]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
39
99
PCA-RP100KAQ PUHZ-P100YHA 11.2 (4.5-12.5) 9.4 (4.9-11.2) 9.5 (3.85-10.65) 8.65 (4.5-10.3)
803
1207
2010
7.24
3
3
5.33 / 5.09 [13.7]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
36
77
PCA-RP125KAQ PUHZ-P125YHA 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
846
1405
2251
8.86
3
4
6.54 / 6.50 [13.8]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
38
101
PCA-RP140KAQ PUHZ-P140YHA 16.0 (5.0-18.0) 13.6 (5.5-15.0) 13.6 (4.25-15.3) 12.5 (5.05-13.8)
905
1671
2576
9.66
3
4
7.44 / 7.67 [13.9]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
39
101
3 Phase System
Note: Indoor price includes separate PAR-30MAA wired remote controller
Page 34
Page 35
Stainless Steel Ceiling Suspended Systems PCA-RP-HAQ Power Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor Outdoor (kg)
(kg)
(£)
(£)
(£)
PCA-RP71HAQ PUHZ-RP71VHA4 7.6 (3.5-10.2) 7.1 (3.3-8.1) 6.45 (3.0-8.65) 6.55 (3.05-7.45)
1132
1092
2224
5.25
1
5
10.02 / 9.93 [19.4]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
41
67
PCA-RP125HAQ
1325
1516
2841
9.63
1
5
18.18 / 17.42 [27.7]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
56
116
1325
1634
2959
9.63
3
5
7.14 / 6.87 [10.7]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
56
126
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
PUHZ-RP125VKA 13.8 (5.0-16.0) 12.5 (5.5-14.0) 11.75 (4.25-13.6) 11.5 (5.05-12.9)
(kW)
3 Phase Systems PCA-RP125HAQ
PUHZ-RP125YKA 13.8 (5.0-16.0) 12.5 (5.5-14.0) 11.75 (4.25-13.6) 11.5 (5.05-12.9)
Note: Indoor price includes separate PAR-30MAA wired remote controller
PCA-RP-HAQ Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
PCA-RP125HAQ PUHZ-P125VHA3 13.8 (5.0-16.0) 12.3 (5.5-14.0) 11.75 (4.25-13.6) 11.3 (5.05-12.9)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase
Starting Current (A) Outdoor
(£)
(£)
(£)
1325
1242
2567
9.59
1
11
19.11 / 19.47 [29.2]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
1325
1405
2730
9.59
3
4
6.73 / 6.86 [14.2]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
(kW)
Indoor Outdoor (kg)
(kg)
50 / 30
56
99
50 / 30
56
101
3 Phase System PCA-RP125HAQ PUHZ-P125YHA
13.8 (5.0-16.0) 12.3 (5.5-14.0) 11.75 (4.25-13.6) 11.3 (5.05-12.9)
Note: Indoor price includes separate PAR-30MAA wired remote controller
Page 36
Page 37
Floor Standing Systems PSA-RP Power Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase
Starting Current (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
System Running Current (A) Heating / Cooling
Indoor Outdoor (kg)
(kg)
(£)
(£)
(£)
PUHZ-RP71VHA4 7.6 (3.5-10.2) 7.1 (3.3-8.1) 6.45 (3.0-8.65) 6.55 (3.05-7.45)
808
1092
1900
5.18
1
5
9.98 / 9.85 [19.7]
6 / 20
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
43
67
PSA-RP100GA PUHZ-RP100VKA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
935
1322
2257
8.10
1
5
14.69 / 13.39 [27.6]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
51
116
PSA-RP125GA PUHZ-RP125VKA 14.0 (5.0-16.0) 12.4 (5.5-14.0) 11.9 (4.25-13.6) 11.4 (5.05-12.9)
987
1516
2503
9.30
1
5
18.40 / 18.44 [27.7]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
51
116
PSA-RP100GA PUHZ-RP100YKA 11.2 (4.5-14.0) 10.0 (4.9-11.4) 9.5 (3.85-11.9) 9.2 (4.5-10.5)
935
1429
2364
8.10
3
5
5.83 / 5.37 [9.1]
6 / 10
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
51
124
PSA-RP125GA PUHZ-RP125YKA 14.0 (5.0-16.0) 12.4 (5.5-14.0)
987
1634
2621
9.30
3
5
7.24 / 7.25 [10.7]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
75 / 30
51
126
System Running Current (A) Heating / Cooling
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
[MAX]
Fuse Rating (A) Indoor / Outdoor
Gas
Liquid
Max Pipe Length / Height (m)
8
14.55 / 13.84 [29.1]
6 / 32
4 Core
15.88(5/8")
9.52(3/8")
6 / 32
4 Core
15.88(5/8")
PSA-RP71GA
(kW)
3 Phase Systems
11.9 (4.25-13.6) 11.4 (5.05-12.9)
Note: Indoor price includes built in PAR-21MAA wired remote controller
PSA-RP Standard Inverter Heat Pump Indoor
Outdoor
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
(kW)
(kW)
(kW)
(kW)
(£)
(£)
(£)
9.5 (3.85-10.65)
8.65 (4.5-10.3)
935
1085
2020
PSA-RP100GA PUHZ-P100VHA3 11.2 (4.5-12.5) 9.4 (4.9-11.2)
PSA-RP125GA PUHZ-P125VHA3 14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
Indoor Outdoor System Price Price Price
Sensible Power Cooling Supply Nominal & UK Phase (kW)
7.80
1
Starting Current (A) Outdoor
987
1242
2229
9.35
1
11
22.08 / 19.42 [29.2]
Indoor Outdoor (kg)
(kg)
50 / 30
51
75
9.52(3/8")
50 / 30
51
99
3 Phase System PSA-RP100GA
PUHZ-P100YHA
11.2 (4.5-12.5) 9.4 (4.9-11.2)
8.65 (4.5-10.3)
935
1207
2142
7.80
3
3
5.23 / 4.97 [14.1]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
51
77
PSA-RP125GA
PUHZ-P125YHA
14.0 (5.0-16.0) 12.3 (5.5-14.0) 11.9 (4.25-13.6) 11.3 (5.05-12.9)
987
1405
2392
9.35
3
4
7.78 / 6.84 [14.2]
6 / 16
4 Core
15.88(5/8")
9.52(3/8")
50 / 30
51
101
9.5 (3.85-10.65)
Note: Indoor price includes built in PAR-21MAA wired remote controller
Page 38
Page 39
Air Curtain Systems PHV DXE Recessed Power Inverter Heat Pump Heat Output Indoor
Outdoor
(kW)
100% / 50%
COP 100% / 50%
Indoor Supply (50Hz) (V)
Indoor Loading (A)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Velocity
Air Volume
(m/s)
(m3/h)
Noise at 3m Max Mounting dB(A) Height (m) 100% / 50%
Fuse Rating (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas
Liquid
Max Pipe Length / Height (m)
Indoor Outdoor (kg)
(kg)
PHV1000R DXE HO PUHZ-RP71VHA4
8.6 / 5.34
2.4 / 3.15
415V*1
7.8*1
2362
1092
3454
9
1400
56
3.5
20
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
45
67
PHV1500R DXE LO
PUHZ-RP71VHA4
10.1 / 5.6
2.3 / 3.4
415V*1
12.7*1
2512
1092
3604
9
2500
58
3.5
20
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
66
67
PHV1500R DXE HO PUHZ-RP140VKA
14.4 / 8.3
2.5 / 3.7
415V*1
12.7*1
2841
1821
4662
9
2600
58
3.5
32
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
67
118
14.1 / 7.9
2.9 / 3.7
*2
415V
*2
15.7
3302
1322
4624
9.5
3300
59
3.5
32
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
85
116
PHV2000R DXE LO
PUHZ-RP100VKA
3 Phase Systems PHV1500R DXE HO
PUHZ-RP140YKA
14.4 / 8.3
2.5 / 3.7
415V*1
12.7*1
2841
1970
4811
9
2600
58
3.5
16
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
67
132
PHV2000R DXE LO
PUHZ-RP100YKA
14.1 / 7.9
2.9 / 3.7
415V*2
15.7*2
3302
1429
4731
9.5
3300
59
3.5
10
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
85
124
PHV2000R DXE HO
PUHZ-RP200YKA
2.4 / 3.2
*2
*2
3409
2870
6279
9
3130
59
3.5
20
2 Core 28.58(1 1/8")
9.52(3/8")
100 / 30
88
135
Velocity
Air Volume
(m/s)
(m3/h)
21.3 / 11.2
415V
15.7
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
PHV DXE Free Standing Power Inverter Heat Pump Heat Output Indoor
Outdoor
(kW)
100% / 50%
COP 100% / 50%
Indoor Supply (50Hz) (V)
Indoor Loading (A)
Indoor Outdoor System Price Price Price (£)
(£)
(£)
Noise at 3m Max Mounting dB(A) Height (m) 100% / 50%
Fuse Rating (A) Outdoor
Interconnecting Cable
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas
Liquid
Max Pipe Length / Height (m)
Indoor Outdoor (kg)
(kg)
PHV1000 DXE HO PUHZ-RP71VHA4
8.6 / 5.34
2.4 / 3.15
415V*1
7.8*1
2362
1092
3454
9
1400
56
3.75
20
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
39
67
PHV1500 DXE LO
10.1 / 5.6
2.3 / 3.4
415V*1
12.7*1
2577
1092
3669
9
2500
58
3.75
20
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
59
67
2.5 / 3.7
*1
*1
2890
1821
4711
9
2600
58
3.75
32
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
60
118
*2
PUHZ-RP71VHA4
PHV1500 DXE HO PUHZ-RP140VKA PHV2000 DXE LO
PUHZ-RP100VKA
14.4 / 8.3
415V
12.7
14.1 / 7.9
2.9 / 3.7
415V
15.7
3012
1322
4334
9.5
3300
59
3.75
32
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
78
116
14.4 / 8.3
2.5 / 3.7
415V*1
12.7*1
2890
1970
4860
9
2600
58
3.75
16
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
60
132
2.9 / 3.7
415V
*2
*2
3012
1429
4441
9.5
3300
59
3.75
10
2 Core
15.88(5/8")
9.52(3/8")
50 / 30
78
124
415V
*2
*2
3119
2870
5989
9
3130
59
3.75
20
2 Core 28.58(1 1/8")
9.52(3/8")
100 / 30
80
135
*2
3 Phase Systems PHV1500 DXE HO PUHZ-RP140YKA PHV2000 DXE LO
PUHZ-RP100YKA
PHV2000 DXE HO PUHZ-RP200YKA
14.1 / 7.9 21.3 / 11.2
2.4 / 3.2
15.7 15.7
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
Page 40
Page 41
Sensible Cooling Wall Mounted System PHV NT Chilled Water Heat Pump System PHV2000 NT V
Indoor
Cooling
Outdoor
EER
(kW)
PHV2000 NT PUHZ-HW140VHA2
SHF
Indoor Loading (A)
System Price (ยฃ)
(kW)
Sensible Cooling
Power Supply Phase Outdoor
Velocity (m/s)
Fuse Running Rating (A) Current (A) Outdoor [MAX] Outdoor
Air Volume (m3/h)
Hydraulic Resistance Indoor / Outdoor
Water Volume Flow Rate (m3/h) Indoor
(kPa @ 3.18 m3/h)
Indoor
Outdoor
(kg)
(kg)
12.0
3.8
1.0
2.7
4967
12.0
1
9
2885
22.2 [35]
40
36 / 15
3.18
90
134
12.0
3.8
1.0
2.7
5172
12.0
3
9
2885
7.6 [13]
16
36 / 15
3.18
90
148
3 Phase System PHV2000 NT Y
PHV2000 NT PUHZ-HW140YHA2
Note: Both systems must be purchased as a whole system and not as individual indoor or outdoor units. System price includes PAR-W21MAA wired remote controller. Water flow temperature to be set to 10ยบC (cannot be set lower). Includes room/return air temperature control, remote On/Off and room over-heat alarm. Test conditions: 35ยบC DB / 27ยบC WB outdoor conditions, 24ยบC DB / 40% relative humidity indoor conditions - validated by BSRIA assessment.
Air Handling Unit Controller PAC-IF012B-E Air Handling Unit Controller Air Handling Unit Controller
Outdoor Unit
PAC-IF012B-E
Size 35
Capacity
Auto Step
(kW)
Heating Cooling PUHZ-RP PUHZ-P (nominal) (nominal) 4.1
3.6
VHA4
-
Manual Step
-
VHA4
Heat Exchanger Volume (cm3)
Pipe Size (mm) Gas / Liquid
Dimensions WxDxH
Weight (kg)
(ยฃ)
PUHZ-(H)(R)P
SUZ-KA
Max Capacity
Min Capacity
(mm)
-
319
12.7 / 6.35
9.52 / 6.35
1050
350
336x69x278
2.5
12.7 / 6.35
1500
500
336x69x278
2.5
SUZ-KA PUHZ-HRP PUHZ-RP PUHZ-HRP VA2
AHUC Price
PAC-IF012B-E
Size 50
6.0
5.0
VHA4
-
VA2
-
VHA4
-
319
12.7 / 6.35
PAC-IF012B-E
Size 60
7.0
6.0
VHA4
-
VA2
-
VHA4
-
319
15.88 / 9.52
15.88 / 6.35
1800
600
336x69x278
2.5
PAC-IF012B-E
Size 71
8.0
7.1
VHA4
-
VA2
VHA2
VHA4
VHA2
319
15.88 / 9.52
15.88 / 9.52
2130
710
336x69x278
2.5
PAC-IF012B-E
Size 100
11.2
10.0
319
15.88 / 9.52
-
3000
1000
336x69x278
2.5
-
3750
1250
336x69x278
2.5
VKA/YKA VHA3/YHA
-
V/YHA2 VKA/YKA V/YHA2
PAC-IF012B-E
Size 125
14.0
12.5
VKA/YKA VHA3/YHA
-
YHA2
VKA/YKA
YHA2
319
15.88 / 9.52
PAC-IF012B-E
Size 140
16.0
14.0
VKA/YKA VHA3/YHA
-
-
VKA/YKA
-
319
15.88 / 9.52
-
4200
1400
336x69x278
2.5
PAC-IF012B-E
Size 200
22.4
19.0
YKA
YHA3
-
-
YKA
-
319
28.58 / 9.52
-
6000
2000
336x69x278
2.5
PAC-IF012B-E
Size 250
27.0
22.0
YKA
YHA3
-
-
YKA
-
319
28.58 / 12.7
-
7500
2500
336x69x278
2.5
Note: One air handling unit controller is required per air handling unit. Cooling: Indoor 27ยบC DB/19ยบC WB, Outdoor 35ยบC DB/24ยบC WB Heating: Indoor 20ยบC DB, Outdoor 7ยบC DB/6ยบC WB.
Page 42
Page 43
Common Multi-Split Combinations Please note this list is not exhaustive
Twin Systems
(including pipe kit)
(2) PLA-RP35BA / (1) PUHZ-RP71VHA4 (2) PLA-RP50BA / (1) PUHZ-RP100VKA (2) PLA-RP60BA / (1) PUHZ-RP125VKA (2) PLA-RP71BA2 / (1) PUHZ-RP140VKA (2) PLA-RP50BA / (1) PUHZ-RP100YKA (2) PLA-RP60BA / (1) PUHZ-RP125YKA (2) PLA-RP71BA2 / (1) PUHZ-RP140YKA (2) PLA-RP100BA3 / (1) PUHZ-RP200YKA (2) PLA-RP125BA2 / (1) PUHZ-RP250YKA
Power Power Power Power Power Power Power Power Power
(2) PLA-RP50BA / (1) PUHZ-P100VHA3 (2) PLA-RP60BA / (1) PUHZ-P125VHA3 (2) PLA-RP71BA / (1) PUHZ-P140VHA3 (2) PLA-RP50BA / (1) PUHZ-P100YHA (2) PLA-RP60BA / (1) PUHZ-P125YHA (2) PLA-RP71BA / (1) PUHZ-P140YHA (2) PLA-RP100BA / (1) PUHZ-P200YHA3 (2) PLA-RP125BA / (1) PUHZ-P250YHA3
Standard Standard Standard Standard Standard Standard Standard Standard
Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter
Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin
Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter
System, Single Phase System, Single Phase System, Single Phase System, Single Phase System, Three Phase System, Three Phase System, Three Phase System, Three Phase System, Three Phase
Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin
System, Single Phase System, Single Phase System, Single Phase System, Three Phase System, Three Phase System, Three Phase System, Three Phase System, Three Phase
£2,103 £2,471 £2,739 £3,180 £2,578 £2,857 £3,329 £4,464 £4,640 £2,234 £2,465 £2,866 £2,356 £2,628 £3,030 £3,776 £4,038
(2) PLA-RP35BA / (1) PUHZ-HRP71VHA2 (2) PLA-RP50BA / (1) PUHZ-HRP100VHA2 (2) PLA-RP50BA / (1) PUHZ-HRP100YHA2 (2) PLA-RP60BA / (1) PUHZ-HRP125YHA2
Zubadan Zubadan Zubadan Zubadan
(2) PCA-RP50KAQ / (1) PUHZ-RP100VKA (2) PCA-RP60KAQ / (1) PUHZ-RP125VKA (2) PCA-RP71KAQ / (1) PUHZ-RP140VKA (2) PCA-RP50KAQ / (1) PUHZ-RP100YKA (2) PCA-RP60KAQ / (1) PUHZ-RP125YKA (2) PCA-RP71KAQ / (1) PUHZ-RP140YKA (2) PCA-RP100KAQ / (1) PUHZ-RP200YKA (2) PCA-RP125KAQ / (1) PUHZ-RP250YKA
Power Inverter Ceiling Suspended, Twin System, Single Phase Power Inverter Ceiling Suspended, Twin System, Single Phase Power Inverter Ceiling Suspended, Twin System, Single Phase Power Inverter Ceiling Suspended, Twin System, Three Phase Power Inverter Ceiling Suspended, Twin System, Three Phase Power Inverter Ceiling Suspended, Twin System, Three Phase Power Inverter Ceiling Suspended, Twin System, Three Phase Power Inverter Ceiling Suspended, Twin System, Three Phase
£2,573 £2,823 £3,230 £2,680 £2,941 £3,379 £4,496 £4,770
(2) PCA-RP50KAQ / (1) PUHZ-P100VHA3 (2) PCA-RP60KAQ / (1) PUHZ-P125VHA3 (2) PCA-RP71KAQ / (1) PUHZ-P140VHA3 (2) PCA-RP50KAQ / (1) PUHZ-P100YHA (2) PCA-RP60KAQ / (1) PUHZ-P125YHA (2) PCA-RP71KAQ / (1) PUHZ-P140YHA (2) PCA-RP100KAQ / (1) PUHZ-P200YHA3 (2) PCA-RP125KAQ / (1) PUHZ-P250YHA3
Standard Inverter Ceiling Suspended, Twin System, Single Phase Standard Inverter Ceiling Suspended, Twin System, Single Phase Standard Inverter Ceiling Suspended, Twin System, Single Phase Standard Inverter Ceiling Suspended, Twin System, Three Phase Standard Inverter Ceiling Suspended, Twin System, Three Phase Standard Inverter Ceiling Suspended, Twin System, Three Phase Standard Inverter Ceiling Suspended, Twin System, Three Phase Standard Inverter Ceiling Suspended, Twin System, Three Phase
£2,336 £2,549 £2,916 £2,458 £2,712 £3,080 £3,862 £4,168
Page 44
Inverter Inverter Inverter Inverter
Cassette, Twin Cassette, Twin Cassette, Twin Cassette, Twin
System, Single Phase System, Single Phase System, Three Phase System, Three Phase
£2,784 £2,994 £3,123 £3,522
(2) PKA-RP35HAL / (1) PUHZ-RP71VHA4 (2) PKA-RP50HAL / (1) PUHZ-RP100VKA (2) PKA-RP60KAL / (1) PUHZ-RP125VKA (2) PKA-RP71KAL / (1) PUHZ-RP140VKA (2) PKA-RP50HAL / (1) PUHZ-RP100YKA (2) PKA-RP60KAL / (1) PUHZ-RP125YKA (2) PKA-RP71KAL / (1) PUHZ-RP140YKA (2) PKA-RP100KAL / (1) PUHZ-RP200YKA
Power Power Power Power Power Power Power Power
(2) PKA-RP50HAL / (1) PUHZ-P100VHA3 (2) PKA-RP60KAL / (1) PUHZ-P125VHA3 (2) PKA-RP71KAL / (1) PUHZ-P140VHA3 (2) PKA-RP50HAL / (1) PUHZ-P100YHA (2) PKA-RP60KAL / (1) PUHZ-P125YHA (2) PKA-RP71KAL / (1) PUHZ-P140YHA (2) PKA-RP100KAL / (1) PUHZ-P200YHA3
Standard Standard Standard Standard Standard Standard Standard
System, Single Phase System, Single Phase System, Single Phase System, Three Phase System, Three Phase System, Three Phase System, Three Phase
£2,212 £2,405 £2,760 £2,334 £2,568 £2,924 £3,676
(2) PKA-RP50HAL / (1) PUHZ-HRP100VHA2 (2) PKA-RP50HAL / (1) PUHZ-HRP100YHA2
Zubadan Inverter Wall Mounted, Twin System, Single Phase Zubadan Inverter Wall Mounted, Twin System, Three Phase
£2,972 £3,101
(2) PSA-RP71GA / (1) PUHZ-RP140VKA (2) PSA-RP71GA / (1) PUHZ-RP140YKA (2) PSA-RP100GA / (1) PUHZ-RP200YKA (2) PSA-RP125GA / (1) PUHZ-RP250YKA
Power Power Power Power
£3,500 £3,649 £4,830 £5,122
(2) PSA-RP71GA / (1) PUHZ-P140VHA3 (2) PSA-RP71GA / (1) PUHZ-P140YHA (2) PSA-RP100GA / (1) PUHZ-P200YHA3 (2) PSA-RP125GA / (1) PUHZ-P250YHA3
Standard Standard Standard Standard
(2) PEAD-RP35JAQ / (1) PUHZ-RP71VHA4 (2) PEAD-RP50JAQ / (1) PUHZ-RP100VKA (2) PEAD-RP60JAQ / (1) PUHZ-RP125VKA (2) PEAD-RP71JAQ / (1) PUHZ-RP140VKA (2) PEAD-RP50JAQ / (1) PUHZ-RP100YKA (2) PEAD-RP60JAQ / (1) PUHZ-RP125YKA (2) PEAD-RP71JAQ / (1) PUHZ-RP140YKA (2) PEAD-RP100JAQ / (1) PUHZ-RP200YKA (2) PEAD-RP125JAQ / (1) PUHZ-RP250YKA
Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase Power Inverter Ceiling Concealed Ducted, Twin System, Single Phase Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase Power Inverter Ceiling Concealed Ducted, Twin System, Three Phase
Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall
Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin
Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall Inverter Wall
Inverter Inverter Inverter Inverter
Floor Floor Floor Floor
Inverter Inverter Inverter Inverter
System, Single Phase System, Single Phase System, Single Phase System, Single Phase System, Three Phase System, Three Phase System, Three Phase System, Three Phase
Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin
Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin
Floor Floor Floor Floor
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
Mounted, Twin Mounted, Twin Mounted, Twin Mounted, Twin
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
£2,083 £2,449 £2,679 £3,074 £2,556 £2,797 £3,223 £4,310
£3,186 £3,350 £4,196 £4,520
£2,043 £2,405 £2,673 £3,108 £2,512 £2,791 £3,257 £4,344 £4,574
Page 45
Common Multi-Split Combinations Please note this list is not exhaustive
(2) PEAD-RP50JAQ / (1) PUHZ-P100VHA3 (2) PEAD-RP60JAQ / (1) PUHZ-P125VHA3 (2) PEAD-RP71JAQ / (1) PUHZ-P140VHA3 (2) PEAD-RP50JAQ / (1) PUHZ-P100YHA (2) PEAD-RP60JAQ / (1) PUHZ-P125YHA (2) PEAD-RP71JAQ / (1) PUHZ-P140YHA (2) PEAD-RP100JAQ / (1) PUHZ-P200YHA3 (2) PEAD-RP125JAQ / (1) PUHZ-P250YHA3
Standard Inverter Ceiling Concealed Ducted, Twin System, Single Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Single Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Single Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase Standard Inverter Ceiling Concealed Ducted, Twin System, Three Phase
£2,168 £2,399 £2,794 £2,290 £2,562 £2,958 £3,710 £3,972
(3) PKA-RP50HAL / (1) PUHZ-P140VHA3 (3) PKA-RP50HAL / (1) PUHZ-P140YHA (3) PKA-RP60KAL / (1) PUHZ-P200YHA3 (3) PKA-RP71KAL / (1) PUHZ-P250YHA3
Standard Standard Standard Standard
(3) PSA-RP71GA / (1) PUHZ-RP250YKA
Power Inverter Floor Mounted, Triple System, Three Phase
£5,653
(3) PSA-RP71GA / (1) PUHZ-P250YHA3
Standard Inverter Floor Mounted, Triple System, Three Phase
£5,051
(2) PEAD-RP35JAQ / (1) PUHZ-HRP71VHA2 (2) PEAD-RP50JAQ / (1) PUHZ-HRP100VHA2 (2) PEAD-RP50JAQ / (1) PUHZ-HRP100YHA2 (2) PEAD-RP60JAQ / (1) PUHZ-HRP125YHA2
Zubadan Inverter Ceiling Concealed Ducted, Twin System, Single Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System, Single Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System,Three Phase Zubadan Inverter Ceiling Concealed Ducted, Twin System,Three Phase
£2,724 £2,928 £3,057 £3,456
(3) PEAD-RP50JAQ / (1) PUHZ-RP140VKA (3) PEAD-RP50JAQ / (1) PUHZ-RP140YKA (3) PEAD-RP60JAQ / (1) PUHZ-RP200YKA (3) PEAD-RP71JAQ / (1) PUHZ-RP250YKA
Power Inverter Ceiling Concealed Ducted, Triple System, Single Phase Power Inverter Ceiling Concealed Ducted, Triple System, Three Phase Power Inverter Ceiling Concealed Ducted, Triple System, Three Phase Power Inverter Ceiling Concealed Ducted, Triple System, Three Phase
£3,487 £3,636 £4,647 £5,030
(3) PEAD-RP50JAQ / (1) PUHZ-P140VHA3 (3) PEAD-RP50JAQ / (1) PUHZ-P140YHA (3) PEAD-RP60JAQ / (1) PUHZ-P200YHA3 (3) PEAD-RP71JAQ / (1) PUHZ-P250YHA3
Standard Inverter Ceiling Concealed Ducted, Triple System, Single Phase Standard Inverter Ceiling Concealed Ducted, Triple System, Three Phase Standard Inverter Ceiling Concealed Ducted, Triple System, Three Phase Standard Inverter Ceiling Concealed Ducted, Triple System, Three Phase
£3,173 £3,337 £4,013 £4,428
Triple Systems
(including pipe kit)
(3) PLA-RP50BA / (1) PUHZ-RP140VKA (3) PLA-RP50BA / (1) PUHZ-RP140YKA (3) PLA-RP60BA / (1) PUHZ-RP200YKA (3) PLA-RP71BA2 / (1) PUHZ-RP250YKA
Power Power Power Power
(3) PLA-RP50BA / (1) PUHZ-P140VHA3 (3) PLA-RP50BA / (1) PUHZ-P140YHA (3) PLA-RP60BA / (1) PUHZ-P200YHA3 (3) PLA-RP71BA / (1) PUHZ-P250YHA3
Standard Standard Standard Standard
(3) PCA-RP50KAQ / (1) PUHZ-RP140VKA (3) PCA-RP50KAQ / (1) PUHZ-RP140YKA (3) PCA-RP60KAQ / (1) PUHZ-RP200YKA (3) PCA-RP71KAQ / (1) PUHZ-RP250YKA
Power Power Power Power
(3) PCA-RP50KAQ / (1) PUHZ-P140VHA3 (3) PCA-RP50KAQ / (1) PUHZ-P140YHA (3) PCA-RP60KAQ / (1) PUHZ-P200YHA3 (3) PCA-RP71KAQ / (1) PUHZ-P250YHA3
Standard Inverter Ceiling Suspended, Triple System, Single Phase Standard Inverter Ceiling Suspended, Triple System, Three Phase Standard Inverter Ceiling Suspended, Triple System, Three Phase Standard Inverter Ceiling Suspended, Triple System, Three Phase
£3,425 £3,589 £4,238 £4,611
(3) PKA-RP50HAL / (1) PUHZ-RP140VKA (3) PKA-RP50HAL / (1) PUHZ-RP140YKA (3) PKA-RP60KAL / (1) PUHZ-RP200YKA (3) PKA-RP71KAL / (1) PUHZ-RP250YKA
Power Power Power Power
£3,588 £3,737 £4,691 £5,014
Page 46
Inverter Inverter Inverter Inverter
Cassette, Triple Cassette, Triple Cassette, Triple Cassette, Triple
Inverter Inverter Inverter Inverter
Inverter Inverter Inverter Inverter
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
Cassette, Triple Cassette, Triple Cassette, Triple Cassette, Triple
Ceiling Ceiling Ceiling Ceiling
Inverter Wall Inverter Wall Inverter Wall Inverter Wall
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
Suspended, Triple Suspended, Triple Suspended, Triple Suspended, Triple
Mounted, Triple Mounted, Triple Mounted, Triple Mounted, Triple
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
£3,586 £3,735 £4,746 £5,138 £3,272 £3,436 £4,112 £4,536 £3,739 £3,888 £4,872 £5,213
Quadruple Systems
Inverter Wall Inverter Wall Inverter Wall Inverter Wall
Mounted, Triple Mounted, Triple Mounted, Triple Mounted, Triple
System, Single Phase System, Three Phase System, Three Phase System, Three Phase
£3,274 £3,438 £4,057 £4,412
(including pipe kit)
(4) PLA-RP50BA / (1) PUHZ-RP200YKA (4) PLA-RP60BA / (1) PUHZ-RP250YKA
Power Inverter Cassette, Quadruple System, Three Phase Power Inverter Cassette, Quadruple System, Three Phase
£5,285 £5,621
(4) PLA-RP50BA / (1) PUHZ-P200YHA3 (4) PLA-RP60BA / (1) PUHZ-P250YHA3
Standard Inverter Cassette, Quadruple System, Three Phase Standard Inverter Cassette, Quadruple System, Three Phase
£4,651 £5,019
(4) PCA-RP50KAQ / (1) PUHZ-RP200YKA (4) PCA-RP60KAQ / (1) PUHZ-RP250YKA
Power Inverter Ceiling Suspended, Quadruple System, Three Phase Power Inverter Ceiling Suspended, Quadruple System, Three Phase
£5,489 £5,789
(4) PCA-RP50KAQ / (1) PUHZ-P200YHA3 (4) PCA-RP60KAQ / (1) PUHZ-P250YHA3
Standard Inverter Ceiling Suspended, Quadruple System, Three Phase Standard Inverter Ceiling Suspended, Quadruple System, Three Phase
£4,855 £5,187
(4) PKA-RP50HAL / (1) PUHZ-RP200YKA (4) PKA-RP60KAL / (1) PUHZ-RP250YKA
Power Inverter Wall Mounted, Quadruple System, Three Phase Power Inverter Wall Mounted, Quadruple System, Three Phase
£5,311 £5,571
(4) PKA-RP50HAL / (1) PUHZ-P200YHA3 (4) PKA-RP60KAL / (1) PUHZ-P250YHA3
Standard Inverter Wall Mounted, Quadruple System, Three Phase Standard Inverter Wall Mounted, Quadruple System, Three Phase
£4,677 £4,969
(4) PEAD-RP50JAQ / (1) PUHZ-RP200YKA (4) PEAD-RP60JAQ / (1) PUHZ-RP250YKA
Power Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase Power Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase
£5,153 £5,489
(4) PEAD-RP50JAQ / (1) PUHZ-P200YHA3 (4) PEAD-RP60JAQ / (1) PUHZ-P250YHA3
Standard Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase Standard Inverter Ceiling Concealed Ducted, Quadruple System, Three Phase
£4,519 £4,887
Page 47
Accessories / Optional Extras Description
Model Ref.
Price (£)
Wall Mounted Units Terminal block CN22 connector
S70 515 716 S71 000 028
2 1
Ceiling Concealed Ducted Units Interface for connection to M-NET System SEZ-KD25-71VAQ Interface for group control and run/fault SEZ-KD25-71VAQ
MAC-399IF MAC-397IF
4-Way Blow Cassette Units Grille for PLA-RP35-140BA(2)(3) Grille for SLZ-KA25-50VAQ Multi function casement PLA-RP35-140BA(2)(3) for fresh air 100mm knockout or to hold the high efficiency filter option High efficiency filter PLA-RP35-140BA(2)(3) Grille and infra-red controller PLA-RP35-140BA(2)(3) Grille with filter lowering function PLA-RP35-140BA(2)(3) ‘I-See Sensor’ corner panel PLA-RP35-140BA(2)(3) Infra-red signal receiver PLA-RP35-140BA(2)(3) Infra-red controller (PAR-SL97A-E) PLA-RP35-140BA(2)(3) Interface for connection to M-NET System SLZ-KA25-50VAQ Interface for group control and run/fault SLZ-KA25-50VAQ
Ceiling Suspended Units Wireless remote controller and adaptor Optional drain lift pump PCA-RP50KAQ Optional drain lift pump PCA-RP60KAQ Optional drain lift pump PCA-RP71-140KAQ Oil mist filter for PCA-RP71/125HAQ (12 pack) Decoration covers (front cover & suspending bracket) for PCA-RP71HAQ Decoration covers (front cover & suspending bracket) for PCA-RP125HAQ
Page 48
113 51
PLP-6BA SLP-2AAW PAC-SH53TM-E
142 76 211
PAC-SH59KF-E PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714 MAC-399IF MAC-397IF
170 250 390 46 46 83 113 51
PAR-SL94B-E PAC-SH83DM-E PAC-SH85DM-E PAC-SH84DM-E PAC-SG38KF-E PAC-SF81KC-E PAC-SF82KC-E
86 93 93 93 37 73 80
Description Outdoor Units Drain socket set PUHZ-RP / PUHZ-P / PUHZ-HRP Air outlet guide PUHZ-RP35-50 Air outlet guide PUHZ-RP60-71 / PUHZ-P100 / PUHZ-P125-250 (2 sets required) / PUHZ-HRP (2 sets required) Air outlet guide PUHZ-RP100-250 (2 sets required) Air protect guide (allows cooling at -15ºC) PUHZ-RP35-50 Air protect guide (allows cooling at -15ºC) PUHZ-RP60-71 / PUHZ-P100 / PUHZ-P125-250 (2 sets required) / PUHZ-HRP71-125 (2 sets required) Air protect guide (allows cooling at -15ºC) PUHZ-RP100-250 (2 sets required)
Model Ref.
Price (£)
PAC-SG61DS-E PAC-SG58SG-E PAC-SG59SG-E
16 40 40
PAC-SH96SG-E PAC-SG56AG-E PAC-SH63AG-E
43 111 127
PAC-SH95AG-E
127
System Control Units Remote on/off adaptor Run/fault indication Remote sensor A/M-NET adaptor Simplified remote controller Wired controller Sub interface board
PAC-SA89TA-E PAC-SF40RM-E PAC-SE41TS-E PAC-SF81MA PAC-YT51CRB PAR-30MAA PAC-SK82SI-E
5 92 19 116 104 70 72
Pipe Kits Multi distribution pipe twin units - 50:50 - sizes 71/100/125/140 Multi distribution pipe twin units - 50:50 - sizes 200/250 Multi distribution pipe triple units - 33:33:33 - sizes 140/200/250
MSDD-50TR-E MSDD-50WR-E MSDT-111R-E
63 90 171
Multi distribution pipe quadruple units - 25:25:25:25 - sizes 200/250
MSDF-1111R-E
313
Power Supply Terminal Kits for PUHZ-RP200/250YKA Power supply terminal kit for PLA-RP Power supply terminal kit for PKA-RP Power supply terminal kit for PCA-RP / PSA-RP Power supply terminal kit for PEAD-RP / PCA-RP-HAQ
PAC-SH52HR-E PAC-SG94HR-E PAC-SG96HR-E PAC-SG97HR-E
21 23 23 23
Page 49
The energy efficient
City Multi VRF range
City Multi
Unique 2-pipe technology provides simultaneous heating and cooling, alongside excellent energy efficiency and corresponding EER/COP ratings. Up to 50 indoor units can be connected to a single outdoor unit, offering the sophistication, control and energy efficiency demanded today.
Energy Efficient VRF Systems Simple technology at its best Many of our systems have an energy label of A, are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to
www.eca.gov.uk
Air Conditioning Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 50
Domestic Heating
Commercial Heating Photovoltaics
A Wide Choice of Models
The YJM-A air sourced outdoor models are modular in design and as such differing combinations of them can be connected together to create the required outdoor unit size needed for a particular application. The new YJM-A models also now make use of an extra large single module. Both the Y and R2 Series come in Standard (-P) and High COP (-EP) versions. In addition, the standard versions allow for space-saving by virtue of the combination of units having a smaller foot print than the high COP versions.
The model line up Size
Series Y
R2
200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 1250
Model Name
8hp
PUHY-EP
n
PURY-P
n
PUHY-P
PURY-EP
n
10hp 12hp 14hp 16hp 18hp 20hp 22hp 24hp 26hp 28hp 30hp 32hp 34hp 36hp 38hp 40hp 42hp 44hp 46hp 48hp 50hp
n
n n n n
n n n n
n n
n
n n n n
n n
n
n
n n n n
n n n n
n n n n
Y Series Heat Pump - Standard Version Y Series (8-12hp) PUHY-P YJM-A 8hp 10hp 12hp
PUHY-P200 YJM-A PUHY-P250 YJM-A PUHY-P300 YJM-A
n n n
n
n n n
n
n n n
n n n
n n
n
n n
n
n
Y Series (36hp) PUHY-P YSJM-A 36hp
PUHY-P900 YSJM-A
Y Series (14-16hp) PUHY-P YJM-A
Y Series (38-40hp) PUHY-P YSJM-A
14hp
38hp
16hp
PUHY-P350 YJM-A PUHY-P400 YJM-A
40hp
PUHY-P950 YSJM-A
PUHY-P1000 YSJM-A
Y Series (18hp) PUHY-P YJM-A
Y Series (42hp) PUHY-P YSJM-A
18hp
42hp
PUHY-P450 YJM-A
PUHY-P1050 YSJM-A
Y Series (20-22hp) PUHY-P YSJM-A
Y Series (44hp) PUHY-P YSJM-A
20hp
44hp
22hp
PUHY-P500 YSJM-A PUHY-P550 YSJM-A
PUHY-P1100 YSJM-A
Y Series (24-26hp) PUHY-P YSJM-A
Y Series (46-48hp) PUHY-P YSJM-A
24hp
46hp
26hp
PUHY-P600 YSJM-A PUHY-P650 YSJM-A
48hp
PUHY-P1150 YSJM-A PUHY-P1200 YSJM-A
Y Series (28-30hp) PUHY-P YSJM-A
Y Series (50hp) PUHY-P YSJM-A
28hp
50hp
30hp
PUHY-P700 YSJM-A PUHY-P750 YSJM-A
34hp
n
n
n
n
n
Y Series (26hp) PUHY-EP YSJM-A
12hp
26hp
PUHY-P800 YSJM-A
Y Series Heat Pump - High COP Version
PUHY-EP650 YSJM-A
Y Series (28hp) PUHY-EP YSJM-A
16hp
28hp
PUHY-EP400 YSJM-A
PUHY-EP700 YSJM-A
Y Series (18hp) PUHY-EP YSJM-A
Y Series (30hp) PUHY-EP YSJM-A
18hp
30hp
PUHY-EP450 YSJM-A
PUHY-EP750 YSJM-A
Y Series (20hp) PUHY-EP YSJM-A
Y Series (32hp) PUHY-EP YSJM-A
20hp
32hp
PUHY-EP500 YSJM-A
PUHY-EP800 YSJM-A
Y Series (22hp) PUHY-EP YSJM-A
Y Series (34hp) PUHY-EP YSJM-A
22hp
34hp
PUHY-EP550 YSJM-A
PUHY-EP850 YSJM-A
Y Series (24hp) PUHY-EP YSJM-A
Y Series (36hp) PUHY-EP YSJM-A
24hp
36hp
PUHY-EP600 YSJM-A
PUHY-EP900 YSJM-A
R2 Series Heat Recovery - Standard Version R2 Series (8-12hp) PURY-P YJM-A 8hp 10hp 12hp
PURY-P200 YJM-A PURY-P250 YJM-A PURY-P300 YJM-A
R2 Series (26-28hp) PURY-P YSJM-A 26hp 28hp
PURY-P650 YSJM-A PURY-P700YSJM-A
R2 Series (14-16hp) PURY-P YJM-A
R2 Series (30-32hp) PURY-P YSJM-A
14hp
30hp
16hp
PURY-P350 YJM-A PURY-P400 YJM-A
32hp
PURY-P750 YSJM-A PURY-P800YSJM-A
R2 Series (18hp) PURY-P YJM-A
R2 Series (34hp) PURY-P YSJM-A
18hp
34hp
PURY-P450 YJM-A
R2 Series (18-24hp) PURY-P YSJM-A(1) 18hp 20hp 22hp 24hp
PURY-P450 YSJM-A1 PURY-P500 YSJM-A PURY-P550 YSJM-A PURY-P600 YSJM-A
PURY-P850 YSJM-A
R2 Series (36hp) PURY-P YSJM-A 36hp
PURY-P900 YSJM-A
R2 Series Heat Recovery - High COP Version R2 Series (8hp) PURY-EP YJM-A
R2 Series (18-20hp) PURY-EP YSJM-A
8hp
18hp
PURY-EP200 YJM-A
20hp
PURY-EP450YSJM-A PURY-EP500YSJM-A
R2 Series (10-12hp) PURY-EP YJM-A
R2 Series (22-24hp) PURY-EP YSJM-A
10hp
22hp
12hp
PUHY-P850 YSJM-A
PUHY-EP300 YJM-A
Y Series (16hp) PUHY-EP YSJM-A
PUHY-P1250 YSJM-A
Y Series (32-34hp) PUHY-P YSJM-A 32hp
n
Y Series (12hp) PUHY-EP YJM-A
PURY-EP250 YJM-A PURY-EP300YJM-A
24hp
PURY-EP550YSJM-A PURY-EP600YSJM-A
R2 Series (14hp) PURY-EP YJM-A
R2 Series (26hp) PURY-EP YSJM-A
14hp
26hp
PURY-EP350 YJM-A
PURY-EP650YSJM-A
Y Series (8hp) PUHY-EP YJM-A
Y Series (10hp) PUHY-EP YJM-A
R2 Series (16hp) PURY-EP YSJM-A
R2 Series (28hp) PURY-EP YSJM-A
8hp
10hp
16hp
28hp
Page 52
PUHY-EP200 YJM-A
PUHY-EP250 YJM-A
PURY-EP400 YSJM-A
PURY-EP700YSJM-A
Page 53
City Multi Product Range Overview Outdoor Units
11.2kW Cooling Capacity Y Series (4/5/6hp)
WY / WR2 Series
Y Series Zubadan
Y Series Replace Multi
R2 Series Replace Multi
Y / R2 Series
Y / R2 Series
PUMY-P100-140V/YHMB
PQ(H/R)Y-P200-300YHM-A
PUHY-HP200/250YHM-A
PUHY-RP200-350YJM-B
PURY-RP200-300YJM-B
PUH/RY-P200-300YJM-A PUH/RY-EP200YJM-A
PUH/RY-P350/400YJM-A PUHY-EP250YJM-A PURY-EP250/300YJM-A
Indoor Units Model / Size
15 (1.7kW)
20 (2.2kW)
25 (2.8kW)
32 (3.6kW)
40 (4.5kW)
50 (5.6kW)
63 (7.1kW)
80 (9.0kW)
100 (11.2kW)
125 (14.0kW)
140kW Cooling Capacity Y / R2 Series
PUH/RY-P450YJM-A PUHY-EP300YJM-A PURY-EP350YJM-A
140 (16.0kW)
200 (22.4kW)
250 (28.0kW)
PLFY-P-VBM-E PLFY-P-VCM-E2 PLFY-P-VLMD-E PMFY-P-VBM-E PEFY-P-VMS1-E PEFY-P-VMA-E PEFY-P-VMH-E PCFY-P-VKM-E PKFY-P-VBM/VHM/VKM-E PFFY-P-VLRM-E PFFY-P-VLRMM-E PFFY-P-VLEM-E PFFY-P-VKM-E GUF-RD3 PWFY-P
Page 54
Page 55
Air Cooled Outdoor Units Y Series (4-6hp) R410A Heat Pump Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Max No. of Indoor Units
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
PUMY-P100VHMB
12.5
11.2
10.4
10.3
3.66
3.34
3.27
2.84
8
PUMY-P125VHMB
16.0
14.0
13.3
12.9
4.33
4.32
3.85
3.66
PUMY-P140VHMB
18.0
15.5
14.9
14.3
5.58
5.35
4.99
PUMY-P100YHMB
12.5
11.2
10.4
10.3
3.63
3.30
3.23
PUMY-P125YHMB
16.0
14.0
13.3
12.9
4.29
4.27
PUMY-P140YHMB
18.0
15.5
14.9
14.3
5.32
5.32
Page 56
Price (ÂŁ)
Running Current (A)
Electrical Supply
Mains Cable No. Cores
Phase
32
220-240v, 50Hz
3
18.3
32
220-240v, 50Hz
23.6
22.7
32
5.32
4.84
16
5
6.29
6.26
5
7.8
7.8
Starting Current
Fuse Rating
Airflow
Dimensions WxDxH
Noise
Weight
High
(dBA)
(kg)
Single
100
49
129
950x330+30x1350
3
Single
100
50
129
950x330+30x1350
220-240v, 50Hz
3
Single
100
51
129
950x330+30x1350
380-415v, 50Hz
4 + earth
3
100
49
142
950x330+30x1350
16
380-415v, 50Hz
4 + earth
3
100
50
142
950x330+30x1350
16
380-415v, 50Hz
4 + earth
3
100
51
142
950x330+30x1350
(A)
Heating
Cooling
(A)
2815
5
15.5
14.1
10
3166
5
18.3
4.53
12
3534
5
2.81
8
2815
5
3.82
3.63
10
3166
4.73
4.52
12
3534
(m3/min)
(mm)
Page 57
Y Series (8-50hp) Standard Heat Pump Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Nominal Nominal UK HP UK COP P UK Nominal Nominal UK HP UK COP P UK Heating Cooling Heating Heating Cooling Heating Cooling Heating Heating Cooling
Max No. of Indoor Units
Price (ÂŁ)
Starting Running Current (A) Current
Fuse Rating
(A)
Heating
Cooling
(A)
Electrical Supply
Mains Cable Phase No. Cores
Airflow
Noise
Weight
High
(dBA)
(kg)
(m3/min)
Dimensions WxDxH (mm)
7.36
5.78
3.23
17
4013
8
9.0
8.6
20
380-415v, 50Hz 4 + earth
3
170
56
190
920x760x1710
7.40
9.25
7.27
4.26
21
5013
8
11.3
11.4
20
380-415v, 50Hz 4 + earth
3
170
58
200
920x760x1710
9.00
12.40
8.97
5.81
26
6138
8
14.2
13.9
25
380-415v, 50Hz 4 + earth
3
170
59
215
920x760x1710
11.19
11.01
14.99
10.85
7.10
30
7161
8
17.2
17.0
32
380-415v, 50Hz 4 + earth
3
210
60
250
1220x760x1710
42.3
12.82
13.11
17.18
12.44
8.46
34
8265
8
19.8
20.2
32
380-415v, 50Hz 4 + earth
3
210
61
250
1220x760x1710
48.7
46.0
14.62
15.47
16.67
13.30
9.75
39
9207
8
22.5
23.9
40
380-415v, 50Hz 4 + earth
3
370
62
290
1750x760x1710
54.8
51.5
15.03
15.38
17.13
13.68
9.69
43
10107
8/8
23.2
23.7
20 / 20 380-415v, 50Hz 4 + earth
3
170 / 170
61
200+200
920+920x760x1710
62.4
60.0
58.0
16.87
17.16
19.23
15.35
10.81
47
11232
8/8
26.0
26.5
25 / 20 380-415v, 50Hz 4 + earth
3
170 / 170
61.5
215+200
920+920x760x1710
69.0
69.2
66.6
63.5
18.88
18.75
21.52
17.18
11.81
50
12255
8/8
29.1
28.9
32 / 20 380-415v, 50Hz 4 + earth
3
210 / 170
62
250+200
1220+920x760x1710
81.5
73.0
73.8
70.9
67.2
20.47
20.39
23.34
18.63
12.85
50
13380
8/8
31.6
31.5
32 / 25 380-415v, 50Hz 4 + earth
3
210 / 170
62.5
250+215
1220+920x760x1710
PUHY-P700YSJM-A
88.0
80.0
88.0
76.6
73.6
22.27
22.47
28.06
20.71
14.49
50
14419
8/8
34.4
34.7
32 / 32 380-415v, 50Hz 4 + earth
3
210 / 210
63
250+250
1220+1220x760x1710
PUHY-P750YSJM-A
95.0
85.0
95.0
82.7
78.2
24.67
24.70
31.08
22.94
15.93
50
15523
8/8
38.1
38.1
32 / 32 380-415v, 50Hz 4 + earth
3
210 / 210
63.5
250+250
1220+1220x760x1710
PUHY-P800YSJM-A
100.0
90.0
100.0
87.0
82.8
25.70
27.10
32.38
23.90
17.48
50
16465
8/8
39.7
41.8
40 / 32 380-415v, 50Hz 4 + earth
3
370 / 210
64
290+250
1750+1220x760x1710
PUHY-P850YSJM-A
108.0
96.0
102.6
95.0
88.3
28.42
29.62
37.80
26.15
18.07
50
17569
8/8
43.9
45.7
40 / 32 380-415v, 50Hz 4 + earth
3
370 / 210
64.5
290+250
1750+1220x760x1710
PUHY-P900YSJM-A
113.0
101.0
107.4
99.4
92.9
30.05
32.06
39.97
27.65
19.56
50
18511
8/8
46.4
49.5
40 / 40 380-415v, 50Hz 4 + earth
3
370 / 370
65
290+290
1750+1750x760x1710
PUHY-P950YSJM-A
119.5
108.0
113.5
105.2
99.4
30.02
30.50
39.93
27.62
18.61
50
19593
8/8/8
46.4
47.1
32 / 25 / 20 380-415v, 50Hz 4 + earth
3
210 / 170 / 170
64.5
250+215+200
1220+920+920x760x1710
PUHY-P1000YSJM-A
127.0
113.0
120.7
111.8
104.0
33.15
32.10
44.09
30.50
19.58
50
20718
8/8/8
51.2
49.6
32 / 25 / 25 380-415v, 50Hz 4 + earth
3
210 / 170 / 170
64.5
250+215+215
1220+920+920x760x1710
PUHY-P1050YSJM-A
132.0
118.0
125.4
116.2
108.6
34.10
33.81
45.35
31.37
20.62
50
21741
8/8/8
52.7
52.2
32 / 32 / 25 380-415v, 50Hz 4 + earth
3
210 / 210 / 170
65
250+250+215 1220+1220+920x760x1710
PUHY-P1100YSJM-A
140.0
124.0
133.0
123.2
114.1
36.08
35.73
47.99
33.19
21.80
50
22764
8/8/8
55.7
55.2
32 / 32 / 32 380-415v, 50Hz 4 + earth
3
210 / 210 / 210
65
250+250+250 1220+1220+1220x760x1710
PUHY-P1150YSJM-A
145.0
130.0
137.8
127.6
119.6
37.27
38.34
49.57
34.29
23.39
50
23706
8/8/8
57.6
59.2
40 / 32 / 32 380-415v, 50Hz 4 + earth
3
370 / 210 / 210
65.5
290+250+250 1750+1220+1220x760x1710
PUHY-P1200YSJM-A
150.0
136.0
142.5
132.0
125.1
39.26
40.84
52.22
36.12
24.91
50
24810
8/8/8
60.6
63.1
40 / 32 / 32 380-415v, 50Hz 4 + earth
3
370 / 210 / 210
66
290+250+250 1750+1220+1220x760x1710
PUHY-P1250YSJM-A
156.5
140.0
148.7
137.7
128.8
40.86
42.94
54.34
37.59
26.19
50
25752
8/8/8
63.1
66.3
40 / 40 / 32 380-415v, 50Hz 4 + earth
3
370 / 370 / 210
66
290+290+250 1750+1750+1220x760x1710
PUHY-P200YJM-A
25.0
22.4
25.0
22.8
21.3
5.84
5.62
PUHY-P250YJM-A
31.5
28.0
31.5
28.7
26.6
7.34
PUHY-P300YJM-A
37.5
33.5
35.6
32.3
31.5
9.25
PUHY-P350YJM-A
45.0
40.0
42.8
38.7
37.6
PUHY-P400YJM-A
50.0
45.0
47.5
43.0
PUHY-P450YJM-A
56.0
50.0
50.7
PUHY-P500YSJM-A
63.0
56.0
57.0
PUHY-P550YSJM-A
69.0
63.0
PUHY-P600YSJM-A
76.5
PUHY-P650YSJM-A
Note: Price includes Twinning Kit where necessary. HP = High Performance, COP P = COP Priority
Page 58
Page 59
Y Series (8-36hp) High COP Heat Pump Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Nominal Nominal UK HP UK COP P UK Nominal Nominal UK HP UK COP P UK Heating Cooling Heating Heating Cooling Heating Cooling Heating Heating Cooling
Max No. of Indoor Units
Price (£)
Starting Running Current (A) Current
Fuse Rating
(A)
Heating
Cooling
(A)
Electrical Supply
Mains Phase Cable No. Cores
Airflow
Noise
Weight
High
(dBA)
(kg)
(m3/min)
Dimensions WxDxH (mm)
6.98
5.48
2.93
17
4588
8
8.5
7.8
20
380-415v, 50Hz 4 + earth
3
170
57
200
920x760x1710
6.73
9.01
7.08
3.87
21
5765
8
11.0
10.4
20
380-415v, 50Hz 4 + earth
3
210
60
250
1220x760x1710
8.03
11.22
8.12
5.18
26
7199
8
12.9
12.4
25
380-415v, 50Hz 4 + earth
3
370
61
290
1750x760x1710
11.41
10.34
15.29
11.07
6.67
35
9257
8/8
17.6
15.9
20 / 20 380-415v, 50Hz 4 + earth
3
170 / 170
60
200+200
920+920x760x1710
46.0
12.90
11.87
14.71
11.74
7.48
39
10434
8/8
19.9
18.3
20 / 20 380-415v, 50Hz 4 + earth
3
210 / 170
62
250+200
1220+920x760x1710
54.8
51.5
14.28
13.30
16.28
12.99
8.38
43
11868
8/8
22.0
20.5
25 / 20 380-415v, 50Hz 4 + earth
3
370 / 170
62.5
290+200
1750+920x760x1710
60.0
58.0
15.78
15.36
17.99
14.36
9.68
47
13045
8/8
24.3
23.7
25 / 20 380-415v, 50Hz 4 + earth
3
370 / 210
63.5
290+250
1750+1220x760x1710
69.2
66.6
63.5
17.30
16.82
19.72
15.74
10.60
50
14479
8/8
26.7
26.0
25 / 25 380-415v, 50Hz 4 + earth
3
370 / 370
64
290+290
1750+1750x760x1710
73.0
73.8
70.9
67.2
18.56
17.46
21.16
16.89
11.00
50
15118
8/8/8
28.6
26.9
20 / 20 / 20 380-415v, 50Hz 4 + earth
3
210 / 170 / 170
63
250+200+200
1220+920+920x760x1710
88.0
80.0
88.0
76.6
73.6
20.00
19.13
25.20
18.60
12.34
50
16552
8/8/8
30.9
29.5
25 / 20 / 20 380-415v, 50Hz 4 + earth
3
370 / 170 / 170
63.5
290+200+200
1750+920+920x760x1710
PUHY-EP200YJM-A
25.0
22.4
25.0
22.8
21.3
5.54
5.09
PUHY-EP250YJM-A
31.5
28.0
31.5
28.7
26.6
7.15
PUHY-EP300YJM-A
37.5
33.5
35.6
32.3
31.5
8.37
PUHY-EP400YSJM-A
50.0
45.0
47.5
43.0
42.3
PUHY-EP450YSJM-A
56.0
50.0
50.7
48.7
PUHY-EP500YSJM-A
63.0
56.0
57.0
PUHY-EP550YSJM-A
69.0
63.0
62.4
PUHY-EP600YSJM-A
76.5
69.0
PUHY-EP650YSJM-A
81.5
PUHY-EP700YSJM-A PUHY-EP750YSJM-A
95.0
85.0
95.0
82.7
78.2
21.93
20.43
27.63
20.39
13.18
50
17729
8/8/8
33.8
31.5
25 / 20 / 20 380-415v, 50Hz 4 + earth
3
370 / 210 / 170
64.5
290+250+200 1750+1220+920x760x1710
PUHY-EP800YSJM-A
100.0
90.0
100.0
87.0
82.8
22.77
21.63
28.69
21.18
13.95
50
19163
8/8/8
35.1
33.4
25 / 25 / 20 380-415v, 50Hz 4 + earth
3
370 / 370 / 170
65
290+290+200 1750+1750+920x760x1710
PUHY-EP850YSJM-A
108.0
96.0
102.6
95.0
88.3
24.65
23.58
32.78
22.68
14.38
50
20340
8/8/8
38.1
36.4
25 / 25 / 20 380-415v, 50Hz 4 + earth
3
370 / 370 / 210
65.5
290+290+250 1750+1750+1220x760x1710
PUHY-EP900YSJM-A
113.0
101.0
107.4
99.4
92.9
25.50
24.81
33.92
23.46
15.13
50
21774
8/8/8
39.4
38.3
25 / 25 / 25 380-415v, 50Hz 4 + earth
3
370 / 370 / 370
66
290+290+290 1750+1750+1750x760x1710
Price
Starting Running Current (A) Current
Note: Price includes Twinning Kit where necessary. HP = High Performance, COP P = COP Priority
Y Series (8-20hp) Zubadan Heat Pump Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Max No. of Indoor Units
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
PUHY-HP200YHM-A
25.0
22.4
28.0
19.9
6.52
6.40
11.02
4.99
17
PUHY-HP250YHM-A
31.5
28.0
35.3
24.9
8.94
9.06
15.11
7.07
PUHY-HP400YSHM-A
50.0
45.0
56.0
40.1
13.35
12.86
22.56
PUHY-HP500YSHM-A
63.0
56.0
70.6
49.8
18.04
18.16
30.49
(£)
Fuse Rating
Electrical Supply
Mains Phase Cable No. Cores
Airflow
Dimensions WxDxH
Noise
Weight
High
(dBA)
(kg)
3
225
56
220
920x760x1710
380-415v, 50Hz 4 + earth
3
225
57
220
920x760x1710
19.8
32 / 32 380-415v, 50Hz 4 + earth
3
225 / 225
59
220+220
920+920x760x1710
28.0
32 / 32 380-415v, 50Hz 4 + earth
3
225 / 225
60
220+220
920+920x760x1710
(A)
Heating
Cooling
(A)
5784
8
10.0
9.8
32
380-415v, 50Hz 4 + earth
21
7228
8
13.8
14.0
32
10.03
34
11649
8/8
20.6
14.16
43
14537
8/8
27.8
(m3/min)
(mm)
Note: Price includes Twinning Kit where necessary
Page 60
Page 61
Y Series (8-36hp) Replace Multi Heat Pump Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Nominal Nominal UK HP UK COP P UK Nominal Nominal UK HP UK COP P UK Heating Cooling Heating Heating Cooling Heating Cooling Heating Heating Cooling
Max No. of Indoor Units
Price (ÂŁ)
Starting Running Current (A) Current
Fuse Rating
(A)
Heating
Cooling
(A)
Electrical Supply
Mains Phase Cable No. Cores
Airflow
Noise
Weight
High
(dBA)
(kg)
(m3/min)
Dimensions WxDxH (mm)
7.34
5.63
4.43
17
5570
8
8.7
8.7
20
380-415v, 50Hz 4 + earth
3
185
56
230
920x760x1710
7.62
9.31
7.15
5.94
21
6961
8
12.1
12.7
20
380-415v, 50Hz 4 + earth
3
185
57
255
920x760x1710
8.98
12.43
9.14
7.36
26
8354
8
15.2
14.4
25
380-415v, 50Hz 4 + earth
3
185
59
255
920x760x1710
12.60
11.79
16.63
12.22
9.67
30
9744
8
20.2
18.9
32
380-415v, 50Hz 4 + earth
3
185
60
255
920x760x1710
42.3
11.38
11.87
14.57
11.04
9.73
32
11230
8/8
17.5
18.3
20+20 380-415v, 50Hz 4 + earth
3
185 / 185
59
230+230
920+920x760x1710
48.7
46.0
12.81
13.77
16.40
11.66
9.64
32
12621
8/8
20.7
22.2
20+20 380-415v, 50Hz 4 + earth
3
185 / 185
59.5
255+230
920+920x760x1710
54.8
51.5
14.44
15.68
18.48
13.14
10.98
32
14012
8/8
24.2
26.2
20+20 380-415v, 50Hz 4 + earth
3
185 / 185
60
255+255
920+920x760x1710
66.2
60.0
58.0
16.62
17.50
21.27
15.12
12.25
32
15405
8/8
27.3
28.7
25+20 380-415v, 50Hz 4 + earth
3
185 / 185
61
255+255
920+920x760x1710
69.0
73.4
66.6
63.5
19.22
18.59
24.60
17.49
13.01
32
16798
8/8
31.1
30.8
25+25 380-415v, 50Hz 4 + earth
3
185 / 185
62
255+255
920+920x760x1710
81.5
73.0
78.2
70.9
67.2
21.73
21.09
27.81
19.77
14.76
32
18188
8/8
35.0
34.0
32+25 380-415v, 50Hz 4 + earth
3
185 / 185
62.5
255+255
920+920x760x1710
PUHY-RP700YSJM-B
88.0
80.0
84.5
76.6
73.6
20.13
22.22
26.57
18.72
18.66
32
19685
8/8/8
33.0
36.4
20+20+20 380-415v, 50Hz 4 + earth
3
185 / 185 / 185
61.5
255+255+230
920+920+920x760x1710
PUHY-RP750YSJM-B
95.0
85.0
91.2
82.7
78.2
21.78
24.14
28.75
20.26
20.28
32
21076
8/8/8
36.5
39.7
20+20+20 380-415v, 50Hz 4 + earth
3
185 / 185 / 185
62
255+255+255
920+920+920x760x1710
PUHY-RP800YSJM-B
100.0
90.0
96.0
87.0
82.8
23.75
25.49
31.35
22.09
21.41
32
22469
8/8/8
39.3
42.0
25+20+20 380-415v, 50Hz 4 + earth
3
185 / 185 / 185
62.5
255+255+255
920+920+920x760x1710
PUHY-RP850YSJM-B
108.0
96.0
103.7
94.0
88.3
26.47
27.11
34.15
24.09
22.77
32
23862
8/8/8
43.2
44.1
25+25+20 380-415v, 50Hz 4 + earth
3
185 / 185 / 185
63.5
255+255+255
920+920+920x760x1710
PUHY-RP900YSJM-B
113.0
101.0
108.5
98.3
92.9
28.39
28.29
36.62
25.83
23.76
32
25255
8/8/8
45.9
45.7
25+25+25 380-415v, 50Hz 4 + earth
3
185 / 185 / 185
64
255+255+255
920+920+920x760x1710
PUHY-RP200YJM-B
25.0
22.4
25.0
22.8
19.9
5.69
5.68
PUHY-RP250YJM-B
31.5
28.0
31.5
28.7
24.9
7.22
PUHY-RP300YJM-B
37.5
33.5
36.0
32.6
31.5
9.42
PUHY-RP350YJM-B
45.0
40.0
43.2
39.2
37.6
PUHY-RP400YSJM-B
50.0
45.0
48.0
43.5
PUHY-RP450YSJM-B
56.0
50.0
53.8
PUHY-RP500YSJM-B
63.0
56.0
60.5
PUHY-RP550YSJM-B
69.0
63.0
PUHY-RP600YSJM-B
76.5
PUHY-RP650YSJM-B
Note: Price includes Twinning Kit where necessary. HP = High Performance, COP P = COP Priority
Page 62
Page 63
R2 Series (8-36hp) Standard Heat Recovery Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Nominal Nominal UK HP UK COP P UK Nominal Nominal UK HP UK COP P UK Heating Cooling Heating Heating Cooling Heating Cooling Heating Heating Cooling
PURY-P200YJM-A
25.0
22.4
25.0
22.8
21.3
5.69
5.18
PURY-P250YJM-A
31.5
28.0
31.5
28.7
26.6
7.32
PURY-P300YJM-A
37.5
33.5
35.6
32.3
31.5
8.78
PURY-P350YJM-A
45.0
40.0
42.8
38.7
37.6
PURY-P400YJM-A
50.0
45.0
47.5
43.0
PURY-P450YJM-A
56.0
50.0
50.7
PURY-P450YSJM-A1
56.0
50.0
50.7
PURY-P500YSJM-A
63.0
56.0
PURY-P550YSJM-A
69.0
PURY-P600YSJM-A
Max No. of Indoor Units
Price (ÂŁ)
Starting Running Current (A) Current
Fuse Rating
(A)
Heating
Cooling
(A)
Electrical Supply
Mains Cable Phase No. Cores
Airflow
Noise
Weight
High
(dBA)
(kg)
(m3/min)
Dimensions WxDxH (mm)
7.17
5.63
2.98
20
4422
8
8.7
8.0
20
380-415v, 50Hz 4 + earth
3
185
56
240
920x760x1710
7.05
9.22
7.25
4.05
25
5530
8
11.3
10.8
20
380-415v, 50Hz 4 + earth
3
185
57
240
920x760x1710
8.67
11.77
8.52
5.59
30
6705
8
13.5
13.4
25
380-415v, 50Hz 4 + earth
3
185
59
245
920x760x1710
10.89
11.33
14.59
10.56
7.31
35
7904
8
16.8
17.5
32
380-415v, 50Hz 4 + earth
3
225
60
270
1220x760x1710
42.3
12.75
13.55
17.09
12.37
8.74
40
9316
8
19.7
20.9
40
380-415v, 50Hz 4 + earth
3
225
61
270
1220x760x1710
48.7
46.0
14.58
14.49
16.62
13.27
9.13
45
10326
8
22.5
22.3
40
380-415v, 50Hz 4 + earth
3
360
62
320
1750x760x1710
48.7
46.0
13.30
12.50
15.16
12.10
7.88
45
10084
8/8
20.5
19.3
20 / 20 380-415v, 50Hz 4 + earth
3
185 / 185
59.5
240+240
920+920x760x1710
57.0
54.8
51.5
15.10
14.85
17.21
13.74
9.36
50
11192
8/8
23.3
22.9
20 / 20 380-415v, 50Hz 4 + earth
3
185 / 185
60
240+240
920+920x760x1710
63.0
62.4
60.0
58.0
16.95
17.30
19.32
15.42
10.90
50
12367
8/8
26.2
26.7
25 / 20 380-415v, 50Hz 4 + earth
3
185 / 185
61
245+240
920+920x760x1710
76.5
69.0
69.2
66.6
63.5
19.07
19.65
21.74
17.35
12.38
50
13542
8/8
29.4
30.3
25 / 25 380-415v, 50Hz 4 + earth
3
185 / 185
62
245+245
920+920x760x1710
PURY-P650YSJM-A
81.5
73.0
73.8
70.9
67.2
20.47
21.53
23.34
18.63
13.56
50
14741
8/8
31.6
33.2
32 / 25 380-415v, 50Hz 4 + earth
3
225 / 185
62.5
270+245
1220+920x760x1710
PURY-P700YSJM-A
88.0
80.0
88.0
76.6
73.6
22.33
23.95
28.14
20.77
15.45
50
16170
8/8
34.5
37.0
40 / 25 380-415v, 50Hz 4 + earth
3
225 / 185
63
270+245
1220+920x760x1710
PURY-P750YSJM-A
95.0
85.0
95.0
82.7
78.2
24.05
26.47
30.30
22.37
17.07
50
17369
8/8
37.1
40.9
40 / 32 380-415v, 50Hz 4 + earth
3
225 / 225
63.5
270+270
1220+1220x760x1710
PURY-P800YSJM-A
100.0
90.0
100.0
87.0
82.8
26.04
28.30
32.81
24.22
18.25
50
18781
8/8
40.2
43.7
40 / 40 380-415v, 50Hz 4 + earth
3
225 / 225
64
270+270
1220+1220x760x1710
PURY-P850YSJM-A
108.0
96.0
102.6
95.0
88.3
28.42
29.26
37.80
26.15
17.85
50
19932
8/8
43.9
45.2
40 / 40 380-415v, 50Hz 4 + earth
3
360 / 225
64.5
320+270
1750+1220x760x1710
PURY-P900YSJM-A
113.0
101.0
107.4
99.4
92.9
30.05
30.23
39.97
27.65
18.44
50
20942
8/8
46.4
46.7
40 / 40 380-415v, 50Hz 4 + earth
3
360 / 360
65
320+320
1750+1750x760x1710
Note: Price includes Twinning Kit where necessary. HP = High Performance, COP P = COP Priority
Page 64
Page 65
R2 Series (8-28hp) High COP Heat Recovery Outdoor Unit Capacity Model Reference
Power Input
(kW)
Nominal Nominal UK HP UK COP P UK Nominal Nominal UK HP UK COP P UK Heating Cooling Heating Heating Cooling Heating Cooling Heating Heating Cooling
PURY-EP200YJM-A
25.0
22.4
25.0
22.8
21.3
5.56
5.07
PURY-EP250YJM-A
31.5
28.0
31.5
28.7
26.6
7.15
PURY-EP300YJM-A
37.5
33.5
35.6
32.3
31.5
8.60
PURY-EP350YJM-A
45.0
40.0
42.8
38.7
37.6
PURY-EP400YSJM-A
50.0
45.0
47.5
43.0
PURY-EP450YSJM-A
56.0
50.0
50.7
PURY-EP500YSJM-A
63.0
56.0
57.0
PURY-EP550YSJM-A
69.0
63.0
PURY-EP600YSJM-A
76.5
PURY-EP650YSJM-A
81.5
PURY-EP700YSJM-A
(kW)
88.0
Max No. of Indoor Units
Price (£)
Starting Running Current (A) Current
Fuse Rating
(A)
Heating
Cooling
(A)
Electrical Supply
Mains Cable Phase No. Cores
Airflow
Noise
Weight
High
(dBA)
(kg)
(m3/min)
Dimensions WxDxH (mm)
7.01
5.50
2.92
20
5033
8
8.5
7.8
20
380-415v, 50Hz 4 + earth
3
185
57
240
920x760x1710
6.76
9.01
7.08
3.89
25
6359
8
11.0
10.4
20
380-415v, 50Hz 4 + earth
3
225
60
270
1220x760x1710
8.25
11.52
8.34
5.32
30
7834
8
13.2
12.7
25
380-415v, 50Hz 4 + earth
3
225
60
270
1220x760x1710
10.58
10.28
14.18
10.26
6.63
35
8998
8
16.3
15.8
32
380-415v, 50Hz 4 + earth
3
360
61
320
1750x760x1710
42.3
11.36
10.41
15.22
11.02
6.71
40
10198
8/8
17.5
16.0
20 / 20 380-415v, 50Hz 4 + earth
3
185 / 185
60
240 + 240
920+920x760x1710
48.7
46.0
12.87
11.99
14.67
11.71
7.55
45
11524
8/8
19.8
18.5
20 / 20 380-415v, 50Hz 4 + earth
3
225 / 185
62
270 + 240
1220+920x760x1710
54.8
51.5
14.38
13.62
16.39
13.09
8.58
50
12999
8/8
22.2
21.0
25 / 20 380-415v, 50Hz 4 + earth
3
225 / 185
62
270 + 240
1220+920x760x1710
62.4
60.0
58.0
15.93
15.40
18.16
14.50
9.70
50
14325
8/8
24.6
23.8
25 / 20 380-415v, 50Hz 4 + earth
3
225 / 225
63
270 + 270
1220+1220x760x1710
69.0
69.2
66.6
63.5
17.38
16.87
19.81
15.82
10.63
50
15800
8/8
26.8
26.0
25 / 25 380-415v, 50Hz 4 + earth
3
225 / 225
63
270 + 270
1220+1220x760x1710
73.0
73.8
70.9
67.2
19.73
19.01
22.49
17.95
11.98
50
17091
8/8
30.4
29.3
32 / 25 380-415v, 50Hz 4 + earth
3
360 / 225
63.5
320 + 270
1750+1220x760x1710
50
18255
8/8
34.0
32.8
32 / 32 380-415v, 50Hz 4 + earth
3
360 / 360
64
320 + 320
1750+1750x760x1710
Noise
Weight (kg)
Dimensions WxDxH
High
(dBA)
80.0
88.0
76.6
73.6
22.05
21.22
27.78
20.51
13.69
Note: Price includes Twinning Kit where necessary. HP = High Performance, COP P = COP Priority
R2 Series (8-12hp) Replace Multi Heat Recovery Outdoor Unit Capacity Model Reference
Power Input
(kW)
(kW)
Nominal Nominal UK HP UK COP P UK Nominal Nominal UK HP UK COP P UK Heating Cooling Heating Heating Cooling Heating Cooling Heating Heating Cooling
PURY-RP200YJM-B
25.0
22.4
24.0
21.8
21.1
5.50
4.95
PURY-RP250YJM-B
31.5
28.0
30.2
27.4
26.3
7.22
PURY-RP300YJM-B
37.5
33.5
36.0
32.6
31.5
8.70
Max No. of Indoor Units
Price (£)
Starting Running Current (A) Current
Fuse Rating
(A)
Heating
Cooling
(A)
Electrical Supply
Mains Cable Phase No. Cores
Airflow (m3/min)
(mm)
7.26
5.34
3.61
20
6404
8
8.9
8.0
20
380-415v, 50Hz 4 + earth
3
225
56
275
1220x760x1710
6.82
9.53
7.00
4.98
25
8006
8
11.9
11.2
20
380-415v, 50Hz 4 + earth
3
225
57
290
1220x760x1710
8.35
11.48
8.44
6.10
30
9607
8
14.6
13.6
25
380-415v, 50Hz 4 + earth
3
225
59
290
1220x760x1710
Note: Price includes Twinning Kit where necessary. HP = High Performance, COP P = COP Priority
Page 66
Page 67
Water Cooled Condensing Units WY Series (8-36hp) R410A Water Cooled Heat Pump Condensing Unit Capacity Model Reference
Power Input
(kW)
(kW)
Max No. of Indoor Units
Running Current (A)
Electrical Supply
Mains Cable No. Cores
Phase
20
380-415v, 50Hz
4 + earth
20
380-415v, 50Hz
11.3
20
12.7
20 / 20
16.1
15.2
8/8
18.6
15440
8/8
16783
8/8
50
18561
15.58
50
18.27
17.19
20.74
19.18
96.0
23.21
101.0
25.67
Starting Current
Fuse Rating
Dimensions WxDxH
Noise
Weight
(dBA)
(kg)
3
47
195
880x550x1160
4 + earth
3
49
195
880x550x1160
380-415v, 50Hz
4 + earth
3
50
195
880x550x1160
380-415v, 50Hz
4 + earth
3
50
195+195
880+880x550x1160
20 / 20
380-415v, 50Hz
4 + earth
3
51
195+195
880+880x550x1160
17.6
20 / 20
380-415v, 50Hz
4 + earth
3
52
195+195
880+880x550x1160
22.6
20.8
20 / 20
380-415v, 50Hz
4 + earth
3
52.5
195+195
880+880x550x1160
26.4
23.9
20 / 20
380-415v, 50Hz
4 + earth
3
53
195+195
880+880x550x1160
8/8/8
22.7
21.5
20 / 20 / 20
380-415v, 50Hz
4 + earth
3
53
195+195+195 880+880+880x550x1160
19881
8/8/8
25.5
24.0
20 / 20 / 20
380-415v, 50Hz
4 + earth
3
53.5
195+195+195 880+880+880x550x1160
50
21201
8/8/8
28.2
26.5
20 / 20 / 20
380-415v, 50Hz
4 + earth
3
54
195+195+195 880+880+880x550x1160
50
22544
8/8/8
32.0
29.6
20 / 20 / 20
380-415v, 50Hz
4 + earth
3
54
195+195+195 880+880+880x550x1160
21.20
50
23887
8/8/8
35.8
32.7
20 / 20 / 20
380-415v, 50Hz
4 + earth
3
54.5
195+195+195 880+880+880x550x1160
23.22
50
25230
8/8/8
39.6
35.8
20 / 20 / 20
380-415v, 50Hz
4 + earth
3
55
195+195+195 880+880+880x550x1160
Nominal Heating
Nominal Cooling
Nominal Heating
Nominal Cooling
PQHY-P200YHM-A
25.0
22.4
4.12
3.92
17
PQHY-P250YHM-A
31.5
28.0
5.80
5.45
21
PQHY-P300YHM-A
37.5
33.5
8.15
7.36
26
PQHY-P400YSHM-A
50.0
45.0
8.65
8.25
34
PQHY-P450YSHM-A
56.0
50.0
10.42
9.84
39
PQHY-P500YSHM-A
63.0
56.0
12.06
11.45
PQHY-P550YSHM-A
69.0
63.0
14.65
PQHY-P600YSHM-A
76.5
69.0
17.12
PQHY-P650YSHM-A
81.5
73.0
PQHY-P700YSHM-A
88.0
PQHY-P750YSHM-A
Price (ÂŁ)
(A)
Heating
Cooling
(A)
5688
8
6.3
6.0
7008
8
8.9
8.4
8351
8
12.5
11457
8/8
13.3
12777
8/8
43
14097
13.46
47
15.48
50
14.74
13.96
80.0
16.51
95.0
85.0
PQHY-P800YSHM-A
100.0
90.0
PQHY-P850YSHM-A
108.0
PQHY-P900YSHM-A
113.0
(mm)
Note: Price includes Twinning Kit where necessary. Condensing unit must be installed inside a building.
Page 68
Page 69
WR2 Series (8-24hp) R410A Water Cooled Heat Recovery Condensing Unit Capacity Model Reference
Power Input
(kW)
(kW)
Max No. of Indoor Units
Nominal Heating
Nominal Cooling
Nominal Heating
Nominal Cooling
PQRY-P200YHM-A
25.0
22.4
4.12
3.96
20
PQRY-P250YHM-A
31.5
28.0
5.80
5.51
25
Price (ÂŁ)
Starting Current
Running Current (A)
Fuse Rating
Electrical Supply
Mains Cable No. Cores
Phase
Noise
Weight
(dBA)
(kg)
Dimensions WxDxH
(A)
Heating
Cooling
(A)
(mm)
5688
8
6.3
6.1
20
380-415v, 50Hz
4 + earth
3
47
181
880x550x1160
7008
8
8.9
8.5
20
380-415v, 50Hz
4 + earth
3
49
181
880x550x1160
12.5
11.5
20
380-415v, 50Hz
4 + earth
3
50
181
880x550x1160
PQRY-P300YHM-A
37.5
33.5
8.15
7.44
30
8351
8
PQRY-P400YSHM-A
50.0
45.0
8.65
8.32
40
11604
8/8
13.3
12.8
20 / 20
380-415v, 50Hz
4 + earth
3
50
181+181
880+880x550x1160
PQRY-P450YSHM-A
56.0
50.0
10.42
9.94
45
12924
8/8
16.1
15.3
20 / 20
380-415v, 50Hz
4 + earth
3
51
181+181
880+880x550x1160
PQRY-P500YSHM-A
63.0
56.0
12.06
11.57
50
14244
8/8
18.6
17.8
20 / 20
380-415v, 50Hz
4 + earth
3
52
181+181
880+880x550x1160
PQRY-P550YSHM-A
69.0
63.0
14.65
13.60
50
15587
8/8
22.6
21.0
20 / 20
380-415v, 50Hz
4 + earth
3
52.5
181+181
880+880x550x1160
PQRY-P600YSHM-A
76.5
69.0
17.12
15.62
50
16930
8/8
26.4
24.1
20 / 20
380-415v, 50Hz
4 + earth
3
53
181+181
880+880x550x1160
Note: Price includes Twinning Kit where necessary. Condensing unit must be installed inside a building.
Page 70
Page 71
Close Control System PFD-P-VM-E Close Control Heat Pump System Capacity Model Reference
Power Input
(kW)
(kW)
SHF
Price (ÂŁ)
Starting Current
Running Current
(A)
(A)
External Static Pressure
Electrical Supply
Mains Cable No. Cores
Phase
16
380-415v, 50Hz
4 + earth
120
20
380-415v, 50Hz
N/A
20
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
Nominal Heating
Nominal Cooling
UK Heating
UK Cooling
PFD-P250VM-E
31.5
28.0
29.1
26.6
2.5
2.5
N/A
N/A
0.93
POA
47
4.9
120
PFD-P500VM-E
63.0
56.0
55.4
51.5
5.0
5.0
N/A
N/A
0.93
POA
68
8.7
PUHY-P250YJM-A
31.5
28.0
28.7
26.6
N/A
POA
8
PUHY-P250YJM-A x2
63.0
56.0
54.8
51.5
N/A
POA
8/8
Refer to Databook Refer to Databook
(Pa)
Fuse Rating
Airflow
Dimensions WxDxH
Noise
Weight
High
(dBA)
(kg)
3
160
59
380
1380x780x1950
4 + earth
3
320
63
520
1980x780x1950
380-415v, 50Hz
4 + earth
3
170
58
200
920x760x1710
20 / 20 380-415v, 50Hz
4 + earth
3
170 / 170
58 / 58
380-415v, 50Hz
4 + earth
3
N/A
49
20 / 20 380-415v, 50Hz
4 + earth
3
N/A
49 / 49
(A)
(m3/min)
(mm)
Outdoor Units Refer to Refer to Refer to Refer to Databook Databook Databook Databook Refer to Refer to Refer to Refer to Databook Databook Databook Databook
N/A
200+200 920+920x760x1710
POA = Price on Application
Note: 2 x PUHY-P250YJM-A units are needed when connected to a PFD-P500VM-E
Condensing Units PQHY-P250YHM-A
31.5
28.0
N/A
N/A
PQHY-P250YHM-A x2
63.0
56.0
N/A
N/A
5.51
5.51 / 5.51 5.45 / 5.45
Note: 2 x PQHY-P250YHM-A units are needed when connected to a PFD-P500VM-E
Page 72
5.45
N/A
N/A
N/A
POA
8
8.5
N/A
N/A
N/A
N/A
POA
8/8
8.5 / 8.5
N/A
20
195
880x550x1160
195+195 880+880x550x1160
POA = Price on Application
Page 73
Indoor Units PLFY-P-VBM-E 2, 3 and 4-Way Blow Ceiling Cassette Indoor Unit Capacity Model Reference
SHF
(kW)
Power Input (kW)
Running Current (A)
Electrical Supply
Mains Cable No. Cores
Phase
(dBA) (m3/min) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi
0.22
220-240v, 50Hz
3
Single
27-28-29-31 11-12-13-14
22[6]
PLP-6BA
0.22
0.29
220-240v, 50Hz
3
Single
27-28-30-31 12-13-14-16
22[6]
PLP-6BA
0.04
0.22
0.29
220-240v, 50Hz
3
Single
27-28-30-31 12-13-14-16
22[6]
PLP-6BA
0.04
0.05
0.29
0.36
220-240v, 50Hz
3
Single
28-29-30-32 14-15-16-18
23[6]
PLP-6BA
982
0.06
0.07
0.43
0.51
220-240v, 50Hz
3
Single
30-32-35-37 16-18-20-22
23[6]
PLP-6BA
0.79
1066
0.14
0.15
0.94
1.00
220-240v, 50Hz
3
Single
34-37-39-41 21-24-27-29
27[6]
PLP-6BA
0.75
1331
0.15
0.16
1.00
1.07
220-240v, 50Hz
3
Single
35-38-41-43 22-25-28-30
27[6]
PLP-6BA
Electrical Supply
Mains Cable No. Cores
Phase
(dBA) (m3/min) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi
Price
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
2.6
0.82
0.96
769
0.02
0.03
0.14
4.3
3.3
0.79
0.91
831
0.03
0.04
5.9
5.3
4.1
0.75
0.83
872
0.03
8.0
7.5
6.7
5.2
0.73
0.79
920
10.0
9.4
8.5
6.5
0.72
0.78
12.5
11.7
10.6
8.1
0.72
16.0
15.0
13.3
10.2
0.70
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PLFY-P32VBM-E
4.0
3.6
4.0
3.7
3.4
PLFY-P40VBM-E
5.0
4.5
5.0
4.7
PLFY-P50VBM-E
6.3
5.6
6.3
PLFY-P63VBM-E
8.0
7.1
PLFY-P80VBM-E
10.0
9.0
PLFY-P100VBM-E
12.5
11.2
PLFY-P125VBM-E
16.0
14.0
Noise
Airflow
Weight (kg)
Grille Ref
Note: Indoor price includes PLP-6BA grille. HP = High Performance, COP P = COP Priority
PLFY-P-VCM-E2 600x600 4-Way Blow Ceiling Cassette Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
Noise
Airflow
Weight (kg)
Grille Ref
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PLFY-P20VCM-E2
2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
660
0.05
0.05
0.23
0.23
220-240v, 50Hz
3
Single
28-31-35
8-9-10
15.5[3]
SLP-2AAW
PLFY-P25VCM-E2
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.95
675
0.05
0.05
0.23
0.23
220-240v, 50Hz
3
Single
28-31-37
8-9-10
15.5[3]
SLP-2AAW
PLFY-P32VCM-E2
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
692
0.06
0.06
0.28
0.28
220-240v, 50Hz
3
Single
29-33-38
8-9-11
17[3]
SLP-2AAW
PLFY-P40VCM-E2
5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
747
0.06
0.06
0.28
0.28
220-240v, 50Hz
3
Single
30-34-39
8-9-11
17[3]
SLP-2AAW
Note: Indoor price includes SLP-2AAW grille. HP = High Performance, COP P = COP Priority
Page 74
Page 75
PLFY-P-VLMD-E 2-Way Blow Ceiling Cassette Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
Electrical Supply
Mains Cable No. Cores
Phase
Noise
Airflow
(dBA) (m3/min) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi
Weight (kg)
Grille Ref
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PLFY-P20VLMD-E
2.5
2.2
2.5
2.3
2.1
1.6
0.90
1.00
868
0.065
0.072
0.30
0.36
220-240v, 50Hz
3
Single
27-30-33
6.5-8.0-9.5
23[6.5]
CMP-40VLW-C
PLFY-P25VLMD-E
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
885
0.065
0.072
0.30
0.36
220-240v, 50Hz
3
Single
27-30-33
6.5-8.0-9.5
23[6.5]
CMP-40VLW-C
0.072
0.30
0.36
220-240v, 50Hz
3
Single
27-30-33
6.5-8.0-9.5
24[6.5]
CMP-40VLW-C
PLFY-P32VLMD-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.85
894
0.065
PLFY-P40VLMD-E
5.0
4.5
5.0
4.7
4.3
3.3
0.70
0.76
984
0.074
0.081
0.34
0.40
220-240v, 50Hz
3
Single
29-33-36
7.0-8.5-10.5
24[6.5]
CMP-40VLW-C
PLFY-P50VLMD-E
6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
1077
0.075
0.082
0.35
0.41
220-240v, 50Hz
3
Single
31-34-37
9.0-11.0-12.5
27[7.5]
CMP-63VLW-C
PLFY-P63VLMD-E
8.0
7.1
8.0
7.5
6.7
5.2
0.70
0.75
1118
0.094
0.101
0.43
0.49
220-240v, 50Hz
3
Single
32-37-39
10.0-13.0-15.5
28[7.5]
CMP-63VLW-C
0.73
0.82
1370
0.140
0.147
0.66
0.72
220-240v, 50Hz
3
Single
33-36-39
15.5-18.5-22.0 44[12.5] CMP-100VLW-C
0.157
0.69
0.75
220-240v, 50Hz
3
Single
36-39-42
17.5-21.0-25.0 47[12.5] CMP-100VLW-C
0.28
1.33
1.35
220-240v, 50Hz
3
Single
Electrical Supply
Mains Cable No. Cores
Phase
(dBA) (m3/min) Lo-Mi1-Mi2-Hi Lo-Mi1-Mi2-Hi
PLFY-P80VLMD-E
10.0
9.0
10.0
9.4
8.5
6.5
PLFY-P100VLMD-E
12.5
11.2
12.5
11.7
10.6
8.1
0.73
0.79
1448
0.150
PLFY-P125VLMD-E
16.0
14.0
16.0
15.0
13.3
10.2
0.73
0.80
1771
0.27
40-42-44-46 24-27-30-33
56[13]
CMP-125VLW-C
Note: Indoor price includes relevant size CMP-VLW-C grille. HP = High Performance, COP P = COP Priority
PMFY-P-VBM-E 1-Way Blow Ceiling Cassette Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Noise
Airflow
Weight
Grille Ref
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
1.6
0.86
1.00
944
0.042
0.042
0.20
0.20
220-240v, 50Hz
3
Single
27-30-33-35 6.5-7.2-8.0-8.7
14[3]
PMP-40BMW
2.7
2.0
0.81
0.95
963
0.044
0.044
0.21
0.21
220-240v, 50Hz
3
Single
32-34-36-37 7.3-8.0-8.6-9.3
14[3]
PMP-40BMW
3.4
2.6
0.76
0.85
974
0.044
0.044
0.21
0.21
220-240v, 50Hz
3
Single
32-34-36-37 7.3-8.0-8.6-9.3
14[3]
PMP-40BMW
4.3
3.3
0.72
0.82
1065
0.054
0.054
0.26
0.26
220-240v, 50Hz
3
Single
33-35-37-39 7.7-8.7-9.7-10.7
14[3]
PMP-40BMW
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PMFY-P20VBM-E
2.5
2.2
2.5
2.3
2.1
PMFY-P25VBM-E
3.2
2.8
3.2
3.0
PMFY-P32VBM-E
4.0
3.6
4.0
3.7
PMFY-P40VBM-E
5.0
4.5
5.0
4.7
(kg)
Note: Indoor price includes PMP-40BMW grille. HP = High Performance, COP P = COP Priority
Page 76
Page 77
PEFY-P-VMS1-E Ultra Thin Ceiling Concealed Ducted Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Noise
Electrical Supply
Mains Cable No. Cores
Phase
Airflow
(dBA) Lo-Mi-Hi (15Pa)
(m3/min) Lo-Mi-Hi
Weight
External Static Pressure
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
PEFY-P15VMS1-E
1.9
1.7
1.9
1.8
1.6
1.2
0.94
1.00
552
0.03
0.05
0.31
0.42
220-240v, 50Hz
3
Single
22-24-28
5.0-6.0-7.0
19
5-15-35-50
PEFY-P20VMS1-E
2.5
2.2
2.5
2.3
2.1
1.6
0.86
1.00
568
0.03
0.05
0.36
0.47
220-240v, 50Hz
3
Single
22-25-29
5.5-6.5-8.0
19
5-15-35-50
PEFY-P25VMS1-E
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
585
0.04
0.06
0.39
0.50
220-240v, 50Hz
3
Single
24-26-30
5.5-7.0-9.0
19
5-15-35-50
PEFY-P32VMS1-E
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
593
0.05
0.07
0.39
0.50
220-240v, 50Hz
3
Single
24-27-32
6.0-8.0-10.0
20
5-15-35-50
PEFY-P40VMS1-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.82
631
0.05
0.07
0.45
0.56
220-240v, 50Hz
3
Single
28-30-33
8.0-9.5-11.0
24
5-15-35-50
PEFY-P50VMS1-E
6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
657
0.07
0.09
0.56
0.67
220-240v, 50Hz
3
Single
30-32-35
9.5-11.0-13.0
24
5-15-35-50
PEFY-P63VMS1-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
677
0.07
0.09
0.61
0.72
220-240v, 50Hz
3
Single
30-33-36
12.0-14.0-16.5
28
5-15-35-50
Electrical Supply
Mains Cable No. Cores
Phase
(kg)
(Pa) Lo-Mi1-Mi2-Hi
Note: HP = High Performance, COP P = COP Priority
PEFY-P-VMA-E Ceiling Concealed Ducted Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Noise
Airflow
(dBA) Lo-Mi-Hi (50Pa)
(m3/min) Lo-Mi-Hi
Weight
External Static Pressure
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
PEFY-P20VMA-E
2.5
2.2
2.5
2.3
2.1
1.6
0.90
1.00
586
0.04
0.06
0.42
0.53
220-240v, 50Hz
3
Single
23-25-26
6.0-7.5-8.5
23
35-50-70-100-150
PEFY-P25VMA-E
3.2
2.8
3.2
3.0
2.7
2.0
0.78
0.90
602
0.04
0.06
0.42
0.53
220-240v, 50Hz
3
Single
23-25-26
6.0-7.5-8.5
23
35-50-70-100-150
PEFY-P32VMA-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.85
610
0.05
0.07
0.44
0.55
220-240v, 50Hz
3
Single
23-26-29
7.5-9.0-10.5
23
35-50-70-100-150
PEFY-P40VMA-E
5.0
4.5
5.0
4.7
4.3
3.3
0.79
0.91
649
0.07
0.09
0.53
0.64
220-240v, 50Hz
3
Single
23-27-30
10-12-14
26
35-50-70-100-150
PEFY-P50VMA-E
6.3
5.6
6.3
5.9
5.3
4.1
0.79
0.88
676
0.09
0.11
0.63
0.74
220-240v, 50Hz
3
Single
25-29-32
12.0-14.5-17.0
26
35-50-70-100-150
PEFY-P63VMA-E
8.0
7.1
8.0
7.5
6.7
5.2
0.78
0.87
698
0.10
0.12
0.90
1.01
220-240v, 50Hz
3
Single
25-29-33
13.5-16.0-19.0
32
35-50-70-100-150
PEFY-P80VMA-E
10.0
9.0
10.0
9.4
8.5
6.5
0.72
0.78
796
0.12
0.14
1.04
1.15
220-240v, 50Hz
3
Single
26-29-34
14.5-18.0-21.0
32
35-50-70-100-150
PEFY-P100VMA-E
12.5
11.2
12.5
11.7
10.6
8.1
0.79
0.89
882
0.22
0.24
1.36
1.47
220-240v, 50Hz
3
Single
28-33-37
23-28-33
42
35-50-70-100-150
PEFY-P125VMA-E
16.0
14.0
16.0
15.0
13.3
10.2
0.77
0.86
1010
0.32
0.34
1.94
2.05
220-240v, 50Hz
3
Single
32-36-40
28-34-40
42
35-50-70-100-150
(kg)
(Pa) Lo-Mi1-Mi2-Mi3-Hi
Note: HP = High Performance, COP P = COP Priority
Page 78
Page 79
PEFY-P-VMH-E High Static Pressure Ceiling Concealed Ducted Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Noise
Electrical Supply
Mains Cable No. Cores
Phase
(dBA) Lo-Hi (150Pa)
Airflow
Weight
(m3/min) Lo-Hi
External Static Pressure
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
PEFY-P80VMH-E
10.0
9.0
10.0
9.4
8.5
6.5
0.74
0.83
1210
0.32
0.32
1.47
1.47
220-240v, 50Hz
3
Single
38-43
18-25
50
100-150-200
PEFY-P100VMH-E
12.5
11.2
12.5
11.7
10.6
8.1
0.80
0.91
1339
0.48
0.48
2.34
2.34
220-240v, 50Hz
3
Single
38-44
26.5-38.0
70
100-150-200
PEFY-P125VMH-E
16.0
14.0
16.0
15.0
13.3
10.2
0.74
0.81
1534
0.48
0.48
2.34
2.34
220-240v, 50Hz
3
Single
38-44
26.5-38.0
70
100-150-200
PEFY-P140VMH-E
18.0
16.0
18.0
16.8
15.2
11.6
0.74
0.82
1688
0.48
0.48
2.35
2.35
220-240v, 50Hz
3
Single
38-44
28-40
70
100-150-200
PEFY-P250VMH-E
31.5
28.0
31.5
29.5
26.5
20.3
0.75
0.84
2174
1.23
1.23
2.0
2.0
380-415v, 50Hz
5
3
52 (130Pa)
72
100
130-260
Electrical Supply
Mains Cable No. Cores
Noise
Airflow
Phase
(dBA) Lo-Mi1-Mi2-Hi
(m3/min) Lo-Mi1-Mi2-Hi
(kg)
(Pa) Lo-Mi-Hi
Note: HP = High Performance, COP P = COP Priority
PCFY-P-VKM-E Ceiling Suspended Indoor Unit Capacity Model Reference
PCFY-P40VKM-E
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
Weight (kg)
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
933
0.04
0.04
0.28
0.28
220-240v, 50Hz
3
Single
29-32-34-36
10-11-12-13
24
PCFY-P63VKM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.72
0.77
1035
0.05
0.05
0.33
0.33
220-240v, 50Hz
3
Single
31-33-35-37
14-15-16-18
32
PCFY-P100VKM-E
12.5
11.2
12.5
11.7
10.6
8.1
0.70
0.75
1285
0.09
0.09
0.65
0.65
220-240v, 50Hz
3
Single
36-38-41-43
21-24-26-28
36
PCFY-P125VKM-E
16.0
14.0
16.0
15.0
13.3
10.2
0.69
0.75
1634
0.11
0.11
0.76
0.76
220-240v, 50Hz
3
Single
36-39-42-44
21-24-27-31
38
Note: HP = High Performance, COP P = COP Priority
Page 80
Page 81
PKFY-P-VBM/VHM/VKM-E Wall Mounted Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
Electrical Supply
Mains Cable No. Cores
Noise
Airflow
Phase
(dBA) Lo-Mi1-Mi2-Hi
(m3/min) Lo-Mi1-Mi2-Hi
Weight (kg)
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PKFY-P15VBM-E
1.9
1.7
1.9
1.8
1.6
1.2
0.75
0.83
458
0.04
0.04
0.20
0.20
220-240v, 50Hz
3
Single
29-31-32-33
4.9-5.0-5.2-5.3
10
PKFY-P20VBM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.71
0.75
466
0.04
0.04
0.20
0.20
220-240v, 50Hz
3
Single
29-31-34-36
4.9-5.2-5.6-5.9
10
PKFY-P25VBM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
478
0.04
0.04
0.20
0.20
220-240v, 50Hz
3
Single
29-31-34-36
4.9-5.2-5.6-5.9
10
PKFY-P32VHM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.76
0.85
483
0.03
0.04
0.30
0.40
220-240v, 50Hz
3
Single
34-37-41
9-10-11
13
PKFY-P40VHM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.74
0.82
497
0.03
0.04
0.30
0.40
220-240v, 50Hz
3
Single
34-38-41
9-10.5-11.5
13
PKFY-P50VHM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.72
0.78
523
0.03
0.04
0.30
0.40
220-240v, 50Hz
3
Single
34-39-43
9-10.5-12
13
PKFY-P63VKM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.78
0.85
548
0.04
0.05
0.30
0.37
220-240v, 50Hz
3
Single
39-45
16-20
21
Electrical Supply
Mains Cable No. Cores
Noise
Airflow
Phase
(dBA) Lo-Hi
(m3/min) Lo-Hi
Note: HP = High Performance, COP P = COP Priority
PFFY-P-VLRM-E Floor Standing Concealed Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Weight
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
1.6
0.81
0.88
638
0.04
0.04
0.19
0.19
220-240v, 50Hz
3
Single
34-40
5.5-6.5
18.5
2.7
2.0
0.70
0.80
648
0.04
0.04
0.19
0.19
220-240v, 50Hz
3
Single
34-40
5.5-6.5
18.5
3.7
3.4
2.6
0.74
0.81
660
0.06
0.06
0.29
0.29
220-240v, 50Hz
3
Single
35-40
7-9
20
4.7
4.3
3.3
0.72
0.79
684
0.065
0.065
0.32
0.32
220-240v, 50Hz
3
Single
38-43
9-11
21
6.3
5.9
5.3
4.1
0.74
0.80
691
0.085
0.085
0.40
0.40
220-240v, 50Hz
3
Single
38-43
12-14
25
8.0
7.5
6.7
5.2
0.73
0.79
733
0.10
0.10
0.46
0.46
220-240v, 50Hz
3
Single
40-46
12-15.5
27
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PFFY-P20VLRM-E
2.5
2.2
2.5
2.3
2.1
PFFY-P25VLRM-E
3.2
2.8
3.2
3.0
PFFY-P32VLRM-E
4.0
3.6
4.0
PFFY-P40VLRM-E
5.0
4.5
5.0
PFFY-P50VLRM-E
6.3
5.6
PFFY-P63VLRM-E
8.0
7.1
(kg)
Note: HP = High Performance, COP P = COP Priority
Page 82
Page 83
PFFY-P-VLRMM-E Floor Standing Concealed Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Noise
Electrical Supply
Mains Cable No. Cores
Phase
Airflow
(dBA) Lo-Mi-Hi (20Pa)
(m3/min) Lo-Mi-Hi
Weight
External Static Pressure
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
PFFY-P20VLRMM-E
2.5
2.2
2.5
2.3
2.1
1.6
0.81
0.88
767
0.04
0.04
0.34
0.34
220-240v, 50Hz
3
Single
31-36-40
4.5-5.5-6.5
18.5
20-40-60
PFFY-P25VLRMM-E
3.2
2.8
3.2
3.0
2.7
2.0
0.70
0.80
778
0.04
0.04
0.34
0.34
220-240v, 50Hz
3
Single
31-36-40
4.5-5.5-6.5
18.5
20-40-60
PFFY-P32VLRMM-E
4.0
3.6
4.0
3.7
3.4
2.6
0.74
0.81
790
0.04
0.04
0.38
0.38
220-240v, 50Hz
3
Single
27-32-37
6.5-7.5-9
20
20-40-60
PFFY-P40VLRMM-E
5.0
4.5
5.0
4.7
4.3
3.3
0.72
0.79
824
0.05
0.05
0.43
0.43
220-240v, 50Hz
3
Single
30-36-40
8-9.5-11
21
20-40-60
PFFY-P50VLRMM-E
6.3
5.6
6.3
5.9
5.3
4.1
0.74
0.80
828
0.05
0.05
0.48
0.48
220-240v, 50Hz
3
Single
32-37-41
10-12-14
25
20-40-60
PFFY-P63VLRMM-E
8.0
7.1
8.0
7.5
6.7
5.2
0.73
0.79
881
0.07
0.07
0.59
0.59
220-240v, 50Hz
3
Single
35-40-44
11-13-15.5
27
20-40-60
Electrical Supply
Mains Cable No. Cores
Phase
(kg)
(Pa) Lo-Mi-Hi
Note: HP = High Performance, COP P = COP Priority
PFFY-P-VLEM-E Floor Standing Exposed Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Noise
Airflow
(dBA) Lo-Hi
(m3/min) Lo-Hi
Single
34-40
5.5-6.5
23
Single
34-40
5.5-6.5
23
3
Single
35-40
7-9
25
220-240v, 50Hz
3
Single
38-43
9-11
26
0.40
220-240v, 50Hz
3
Single
38-43
12-14
30
0.46
220-240v, 50Hz
3
Single
40-46
12-15.5
32
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
1.6
0.81
0.88
715
0.04
0.04
0.19
0.19
220-240v, 50Hz
3
2.0
0.70
0.80
728
0.04
0.04
0.19
0.19
220-240v, 50Hz
3
3.4
2.6
0.74
0.81
743
0.06
0.06
0.29
0.29
220-240v, 50Hz
4.7
4.3
3.3
0.72
0.79
768
0.065
0.065
0.32
0.32
6.3
5.9
5.3
4.1
0.74
0.80
777
0.085
0.085
0.40
8.0
7.5
6.7
5.2
0.73
0.79
824
0.10
0.10
0.46
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PFFY-P20VLEM-E
2.5
2.2
2.5
2.3
2.1
PFFY-P25VLEM-E
3.2
2.8
3.2
3.0
2.7
PFFY-P32VLEM-E
4.0
3.6
4.0
3.7
PFFY-P40VLEM-E
5.0
4.5
5.0
PFFY-P50VLEM-E
6.3
5.6
PFFY-P63VLEM-E
8.0
7.1
Weight (kg)
Note: HP = High Performance, COP P = COP Priority
Page 84
Page 85
PFFY-P-VKM-E Floor Standing Exposed Indoor Unit Capacity Model Reference
SHF
(kW)
Price
Power Input (kW)
Running Current (A)
Electrical Supply
Mains Cable No. Cores
Noise
Airflow
Phase
(dBA) Lo-Mi1-Mi2-Hi
(m3/min) Lo-Mi1-Mi2-Hi
0.20
220-240v, 50Hz
3
Single
27-31-34-37
5.9-6.8-7.6-8.7
15
0.20
0.20
220-240v, 50Hz
3
Single
28-32-35-38
6.1-7.0-8.0-9.1
15
0.20
0.20
220-240v, 50Hz
3
Single
28-32-35-38
6.1-7.0-8.0-9.1
15
0.24
0.24
220-240v, 50Hz
3
Single
35-38-42-44
8.0-9.0-9.5-10.7
15
(UK)
High Sensible (UK)
(£)
Nominal Heating
Nominal Cooling
Heating
Cooling
1.6
0.81
0.88
680
0.025
0.025
0.20
2.7
2.0
0.74
0.85
693
0.025
0.025
3.4
2.6
0.71
0.77
706
0.025
0.025
4.3
3.3
0.70
0.76
730
0.028
0.028
Price
Power Input
Running Current (A)
Nominal Heating
Nominal Cooling
UK HP Heating
UK COP P Heating
UK Cooling
UK High Sensible Cooling
PFFY-P20VKM-E
2.5
2.2
2.5
2.3
2.1
PFFY-P25VKM-E
3.2
2.8
3.2
3.0
PFFY-P32VKM-E
4.0
3.6
4.0
3.7
PFFY-P40VKM-E
5.0
4.5
5.0
4.7
Weight (kg)
Note: HP = High Performance, COP P = COP Priority
Lossnay Outdoor Air Processing Units GUF-RD3 Lossnay Outdoor Air Processing Unit Capacity Model Reference
Nominal Heating
Nominal Cooling
(kW)
UK HP Heating
UK COP P Heating
UK Cooling
(£)
(kW)
Low
High
Electrical Supply
Mains Cable No. Cores
Noise
Airflow
Phase
(dBA) Lo-Hi
(m3/h) Lo-Hi
Weight (kg)
GUF-50RD3
6.42 (2.25)
5.29 (1.66)
6.42 (2.25)
5.93 (2.08)
5.03 (1.58)
1657
0.265
0.70
1.15
220-240v, 50Hz
3
Single
33.5-34.5
400-500
54
GUF-100RD3
13.00 (4.70)
10.81 (3.49)
13.00 (4.70)
12.01 (4.34)
10.27 (3.32)
2324
0.505
1.73
2.20
220-240v, 50Hz
3
Single
38-39
800-1000
92
Note: HP = High Performance, COP P = COP Priority
Page 86
Page 87
VRF Heat Pump Boilers PWFY-P VRF Heat Pump Boiler Model Reference
Pipe Size
Capacity (kW) Capacity (kW) Capacity (kW) UK Nominal Nominal Heating Heating Cooling
Pipe Size
Pipe Size
mm (in)
mm (in)
Gas Refrigerant
Liquid Refrigerant
Price
Weight
Water
(£)
(kg)
mm (in)
Dimensions WxDxH (mm)
Electrical Supply
Phase
Mains Cable No. Cores
PWFY-P100VM-E-BU
12.5
-
12.5
15.88 (5/8”)
9.52 (3/8”)
19.05 (3/4”)
3178
60
450x300x785(800)
220-240v, 50Hz
Single
3
PWFY-P100VM-E-AU
12.5
11.2
10.4
15.88 (5/8”)
9.52 (3/8”)
19.05 (3/4”)
957
35
450x300x785(800)
220-240v, 50Hz
Single
3
PWFY-P200VM-E-AU
25.0
22.4
20.8
19.05 (3/4”)
9.52 (3/8”)
19.05 (3/4”)
1590
38
450x300x785(800)
220-240v, 50Hz
Single
3
Water Volume in PWFY-P Heat Exchanger
Price
Velocity
(£)
(m/s)
2098
9
Chilled Water Wall Mounted Unit VRF PHV NT Sensible Cooling, Wall Mounted Indoor Unit Model Reference
Capacity (kW)
SHF
Water Volume Flow Rate (m3/h)
VRF PHV2000 NT
12.0
1.0
3.18
Hydraulic Hydraulic Resistance Resistance of PWFY-P (kPa @ 3.18 m3/h) 36
Water Volume of Coil
(kPa @ 3.18 m3/h)
(litres)
38*1
5.1
Air Volume
Noise @ 3m
(m3/h)
(dBA)
2885
59
Weight (kg)
Dimensions WxDxH (mm)
(A)
Electrical Supply
Phase
Outdoor Unit Model
2.7
220-240v, 50Hz
Single
PUHY / PURY / PQHY / PQRY
Loading
(litres)
2.09
90
2296x377x255
Note: Price includes PAR-W21MAA wired remote controller. For use with a Mitsubishi Electric PWFY-P200VM-E-AU water cooling unit as part of a VRF system. Water flow temperature from the PWFY-P is to be set to 10ºC (cannot be set lower) Test conditions: 35ºC DB / 27ºC WB outdoor conditions, 24ºC DB / 40% relative humidity indoor conditions - validated by BSRIA tests. *1 Without strainer.
Page 88
Page 89
VRF Air Curtains VRF PHV DXE Recessed Heat Pump Air Curtain Indoor
Heat Output
Indoor Supply
(kW)
(50Hz) (V)
VRF PHV1000R DXE HO
9
415V*1
VRF PHV1500R DXE LO
10.6
VRF PHV1500R DXE HO VRF PHV2000R DXE LO VRF PHV2000R DXE HO
Price
Velocity
Air Volume
Noise at 3m
(m/s)
(m3/h)
dB(A)
Max Mounting Height (m)
Indoor
(£)
7.8*1
3231
9
1400
56
3.5
45
PUMY / PUHY / PURY / PQHY / PQRY
415V*1
12.7*1
3434
9
2500
58
3.5
66
PUMY / PUHY / PURY / PQHY / PQRY
15.1
415V*1
12.7*1
3714
9
2600
58
3.5
67
PUMY / PUHY / PURY / PQHY / PQRY
16.4
415V
*2
*2
4261
9.5
3300
59
3.5
85
PUMY / PUHY / PURY / PQHY / PQRY
415V
*2
*2
4611
9
3130
59
3.5
88
PUHY / PURY / PQHY / PQRY
Price
Velocity
Air Volume
Noise at 3m
(m/s)
(m3/h)
dB(A)
Max Mounting Height (m)
Indoor
(£)
21.4
Loading
(A)
15.7 15.7
(kg)
Outdoor Unit Model
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000R DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
VRF PHV DXE Free Standing Heat Pump Air Curtain Indoor
Heat Output
Indoor Supply
(kW)
(50Hz) (V)
VRF PHV1000 DXE HO
9
415V*1 *1
Loading
(A)
(kg)
Outdoor Unit Model
2939
9
1400
56
3.75
39
PUMY / PUHY / PURY / PQHY / PQRY
*1
12.7
3204
9
2500
58
3.75
59
PUMY / PUHY / PURY / PQHY / PQRY
7.8*1
VRF PHV1500 DXE LO
10.6
415V
VRF PHV1500 DXE HO
15.1
415V*1
12.7*1
3477
9
2600
58
3.75
60
PUMY / PUHY / PURY / PQHY / PQRY
VRF PHV2000 DXE LO
16.4
415V*2
15.7*2
3957
9.5
3300
59
3.75
78
PUMY / PUHY / PURY / PQHY / PQRY
21.4
*2
*2
4397
9
3130
59
3.75
80
PUHY / PURY / PQHY / PQRY
VRF PHV2000 DXE HO
415V
15.7
Notes: *1 for units with electric heaters disabled, 240v power supply 1.8 amp load (1.3 amp load for VRF PHV1000 DXE HO) *2 for units with electric heaters disabled, 240v power supply 2.7 amp load.
Page 90
Page 91
BC Controllers / Water System Connection Box BC Controllers Power Input
Running Current
Model Reference
Number of Connections
CMB-P104V-G1
4
0.085
0.36
CMB-P105V-G1
5
0.104
0.44
CMB-P106V-G1
6
0.123
0.52
(kW)
(A)
Price
Electrical Supply
Mains Cable No. Cores
Phase
Weight (kg)
1462
220-240v, 50Hz
3
Single
24
1744
220-240v, 50Hz
3
Single
27
2003
220-240v, 50Hz
3
Single
28
Electrical Supply
Mains Cable No. Cores
Phase
Weight (kg)
(£)
Note: CMB-P-V-G1 units are for use with PURY-(E)P200-350YJM-A & PQRY-P200-300YHM-A only.
Master BC Controllers Price
Model Reference
Number of Connections
CMB-P108V-GA1
8
0.161
0.68
2634
220-240v, 50Hz
3
Single
43
CMB-P1010V-GA1
10
0.198
0.83
3168
220-240v, 50Hz
3
Single
48
CMB-P1013V-GA1
13
0.255
1.07
3882
220-240v, 50Hz
3
Single
55
CMB-P1016V-GA1
16
0.312
1.30
4726
220-240v, 50Hz
3
Single
62
CMB-P1016V-HA1
16
0.312
1.30
4553
220-240v, 50Hz
3
Single
69
Electrical Supply
Mains Cable No. Cores
Phase
Weight (kg)
Power Input
(kW)
Running Current
(A)
(£)
Note: CMB-P-V-GA1 units are for use with PURY-(E)P200-650Y(S)JM-A(1) & PQRY-P200-600Y(S)HM-A only. CMB-P1016V-HA1 unit is for use with PURY-P700-900YSJM-A only.
Slave BC Controllers Power Input
Number of Connections
CMB-P104V-GB1
4
0.076
0.32
1200
220-240v, 50Hz
3
Single
22
CMB-P108V-GB1
8
0.151
0.63
2346
220-240v, 50Hz
3
Single
32
CMB-P1016V-HB1
16
0.301
1.26
4092
220-240v, 50Hz
3
Single
55
Price
Electrical Supply
Mains Cable No. Cores
Phase
Weight (kg)
220-240v, 50Hz
3
Single
20
(kW)
Running Current
Price
Model Reference
(A)
(£)
Water System Connection Box (WCB) Model Reference
Number of Connections
CMB-PW202V-j
2
Page 92
Power Input 0.024
(kW)
Running Current 0.10
(A)
(£)
1043
Page 93
Air Handling Unit Controllers Air Handling Unit Controller Model Reference
Unit Size (Air Handling Unit)
Allowed Heat Exchanger Capacity (kW) Heating
Allowed Heat Exchanger Capacity (kW) Cooling
Allowed Standard Heat Exchanger Evaporator Path Volume (cm3) Number *1
Price (£)
Reference Air Flow Rate (m3/h)*3
Dimensions (WxDxH) ( ) = Including mountings
Weight (kg)
PAC-AH125M-j
P100
10.0 - 12.5
9.0 - 11.2
1500 - 2850
4-5
606
2000
328 x 104 (122) x 378 (420)
5
PAC-AH125M-j
P125
12.5 - 16.0
11.2 - 14.0
1900 - 3550
4-5
606
2500
328 x 104 (122) x 378 (420)
5
PAC-AH140M-j
P140
16.0 - 18.0
14.0 - 16.0
2150 - 4050
5-6
632
3000
328 x 104 (122) x 378 (420)
5
PAC-AH250M-j
P200
18.0 - 25.0
16.0 - 22.4
3000 - 5700
6 - 10
662
4000
328 x 104 (122) x 378 (420)
5
328 x 104 (122) x 378 (420)
5
25.0 - 31.5
22.4 - 28.0
3750 - 7100
8 - 10
662
5000
P400*2
40.0 - 50.0
36.0 - 45.0
6000 - 11400
16 - 20
1128
8000
328 x 104 (122) x 378 (420)
5
P500*
50.0 - 63.0
45.0 - 56.0
7500 - 14200
16 - 20
1128
10000
328 x 104 (122) x 378 (420)
5
PAC-AH250M-j
P250
PAC-AH500M-j PAC-AH500M-j
2
Note: One air handling unit controller is required per air handling unit. Saturated refrigerant temperature at exit of evaporator = 8.5ºC, SH=5K, liquid temperature = 25ºC, air = 27ºCDB/19ºCWB. *1 When the diameter of the heat exchanger tube is ø9.52. *2 P400 and P500 are not compatible with PURY and PQRY. *3 If using in combination with standard indoor units, then these figures do not apply.
APPLICABLE OUTDOOR / CONDENSING UNITS PUHY-P Y(S)JM-A PUHY-EP Y(S)JM-A PUHY-HP Y(S)HM-A PUHY-RP Y(S)JM-B PURY-P Y(S)JM-A PURY-EP Y(S)JM-A PURY-RP YJM-B PQHY-P Y(S)HM-A PQRY-P Y(S)HM-A
Page 94
Page 95
Accessories / Optional Extras Description Outdoor Units Branch Pipe (Joint) for size 200 or below - total capacity of indoor units Branch Pipe (Joint) for size 201-400 - total capacity of indoor units Branch Pipe (Joint) for size 401-650 - total capacity of indoor units or first branch of (E)P450-P650 Branch Pipe (Joint) for size 651 or above - total capacity of indoor units or first branch of P700-P1250 / EP700-EP900 Branch Pipe for 2 branches (PUMY) Twinning Kit for PUHY-P500-650YSJM-A / PUHY-EP400-600YSJM-A / PUHY-HP400-500YSHM-A / PQHY-P400-600YSHM-A Twinning Kit for PUHY-P700-900YSJM-A Twinning Kit for PUHY-P950-1250YSJM-A / PUHY-EP650-900YSJM-A / PQHY-P650-900YSHM-A Twinning Kit for PUHY-RP400-650YSJM-B Twinning Kit for PUHY-RP700-900YSJM-B Twinning Kit for PURY-P450-650YSJM-A(1) / PURY-EP400-600YSJM-A Twinning Kit for PURY-P700-800YSJM-A Twinning Kit for PURY-EP650-700YSJM-A Twinning Kit for PURY-P850-900YSJM-A Twinning Kit for PQRY-P400-600YSHM-A PQFY Auto-Changeover controller VRF AHU Interface (for use with 24v AC signals) Energy Monitoring Connector 4-Way Blow Cassette Units Grille for PLFY-P-VBM-E Grille for PLFY-P-VCM-E2 Grille and infra-red controller for PLFY-P-VBM-E Grille with filter lowering function for PLFY-P-VBM-E ‘I -See Sensor’ corner panel for PLFY-P-VBM-E Infra-red signal receiver for PLFY-P-VBM-E Infra-red Controller (PAR-SL97A-E) for PLFY-P-VBM-E
Page 96
Model Ref.
Price (£)
Description
Model Ref.
Price (£)
CMP-40VLW-C CMP-63VLW-C CMP-100VLW-C CMP-125VLW-C PAC-KH11OF
142 197 237 422 75
CMY-Y102S-G2 CMY-Y102L-G2 CMY-Y202-G2
55 69 74
CMY-Y302-G2
93
2-Way Blow Cassette Units Grille for PLFY-P20-40VLMD-E Grille for PLFY-P50-63VLMD-E Grille for PLFY-P80-100VLMD-E Grille for PLFY-P125VLMD-E OA duct flange for PLFY-P20-100VLMD-E
CMY-Y62-G-E CMY-Y100VBK2
52 81
1-Way Blow Cassette Units Grille for PMFY-P-VBM-E
PMP-40BMW
225
CMY-Y200VBK2 CMY-Y300VBK2
97 177
CMY-RP100VBK CMY-RP200VBK CMY-R100VBK CMY-R200VBK CMY-R100XLVBK CMY-R200XLVBK CMY-Q100VBK ACH1 ACH2 PAC-CN32WHMC-UK
90 193 132 149 259 290 228 140 140 5
Ceiling Concealed Ducted Units Drain lift-up mechanism for PEFY-P-VMH-E Long life filter for PEFY-P80VMH-E Long life filter for PEFY-P100-140VMH-E Long life filter for PEFY-P250VMH-E Filter box for PEFY-P80VMH-E (necessary when long life filter is used) Filter box for PEFY-P100-140VMH-E (necessary when long life filter is used) Filter box for PEFY-P250VMH-E (necessary when long life filter is used)
PAC-KE04DM-F PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F
172 53 69 121 161 169 190
BC Controllers Joint pipe Cover cap for CMB-PW202V-J
CMY-R160-J1 CMY-S202-J
46 64
Indoor Units Remote sensor
PAC-SE41TS-E
19
VRF Heat Pump Boilers Controller Thermistor (10m cable)
PAR-W21MAA THERM-10M
120 20
Close Control System Inverter (soft start) for PFD-P250VM-E Inverter (soft start) for PFD-P500VM-E
PFD-P250-INV PFD-P500-INV
723 1204
PLP-6BA SLP-2AAW PLP-6BALM PLP-6BAJ PAC-SA1ME-E PAR-SA9FA-E S70E40714
142 76 250 390 46 46 83
Page 97
The Unbeatable
Lossnay The Lossnay allows the extraction of stale air and efficient recovery of heating or cooling energy to treat incoming fresh air. Whatever your environment, it’s simple to improve it with Lossnay.
Lossnay Total Heat Exchangers
Simple technology at its best Many of our systems are registered on the Energy Technology List and hence qualify for 100% first year enhanced capital allowances. For further information please go to www.eca.gov.uk
Air Conditioning Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Page 98
Domestic Heating
Commercial Heating Photovoltaics
Lossnay Residential Model Lossnay VL 100U, Residential Model Power Consumption
Model Reference VL 100U
Airflow (W)
(£)
(dBA) Lo-Hi
Mains Cable No. Cores
Temperature Exchange Efficiency (%)
200
29.5-39
3
Max Airflow
Price (£)
Max Noise
(m3/h)
520
950
Price
(m3/h)
Lo-Hi
Lo-Hi
23-26
65-105
Noise
Weight (kg)
Duct Size (mm)
Fuse Rating (A)
77-70
6.5
2xØ75
6
Mains Cable No. Cores
Max Temperature Exchange Efficiency (%)
Weight (kg)
Duct Size (mm)
Fuse Rating (A)
3
90
45
200
6
Lo-Hi
Note: Unit is Single phase 240v, 50hz
DC Lossnay Model Lossnay LGH-RSDC-E, DC Model Model Reference
Max Power Input
Starting Current
(W)
(A)
279
2
LGH-50RSDC-E
Max External Static Pressure (Pa)
102
(dBA)
35
Note: Unit is Single phase 240v, 50hz
Page 100
Page 101
Lossnay Commercial Models Lossnay LGH RX5-E, Commercial Series Max Running Current
Mains Cable No. Cores
Temperature Exchange Efficiency (%)
Weight (kg)
Duct Size (mm)
Fuse Rating (A)
29
3
85.5
20
100
6
539
27.5
3
83.5
20
150
6
709
32.5
3
88
29
150
6
500
874
35
3
86
32
200
6
650
1092
35
3
86
40
200
6
1.75
800
1280
35.5
3
87.5
53
250
6
4.6
2.40
1000
1469
38
3
87
59
250
6
Max Power Input
Starting Current
(W)
(A)
Max Airflow
Price
(m3/h)
(£)
LGH-15RX5-E
110
0.8
0.46
150
457
LGH-25RX5-E
129
0.9
0.55
250
LGH-35RX5-E
212
2.4
0.92
350
LGH-50RX5-E
286
3.0
1.25
LGH-65RX5-E
380
4.4
1.80
LGH-80RX5-E
415
3.8
LGH-100RX5-E
535
Model Reference
(A)
Max Noise (dBA)
LGH-150RX5-E
830
7.3
3.50
1500
2524
40.5
3
81
105
(SA,RA)250 (OA,EA)270x700
10
LGH-200RX5-E
1100
11.9
4.80
2000
2884
41
3
83
118
(SA,RA)250 (OA,EA)270x700
16
Note: All units are Single phase 240v, 50hz
Accessories / Optional Extras Description
Model Ref.
Remote Controllers Lossnay remote controller for LGH RX5-E Lossnay Fan Speed Controller
PZ-60DR-E
High Efficiency Filters High efficiency filter for LGH-15RX5-E / LGH-25RX5-E High efficiency filter for LGH-35RX5-E High efficiency filter for LGH-50RX5-E High efficiency filter for LGH-65RX5-E High efficiency filter for LGH-80RX5-E / LGH-150RX5-E (2 sets) High efficiency filter for LGH-100RX5-E / LGH-200RX5-E (2 sets)
Page 102
Price (£) 80
Lossnay-5-FSC
207
PZ-25RFM PZ-35RFM PZ-50RFM PZ-65RFM PZ-80RFM PZ-100RFM
101 109 118 187 135 162
Page 103
A Wide Range of Control Options The need for control is paramount in order to optimise the performance of any air conditioning system and minimise its running costs. Mitsubishi Electric offer a wide range of control options designed to do just this.
Controls
With the array of comprehensive control systems available from Mitsubishi Electric, it becomes simple to design and install air conditioning systems. From a simple hand held controller to an AG150 system you are in control.
A Comprehensive Range of Control Options
Air Conditioning Domestic Heating Page 104
Commercial Heating Photovoltaics
Core Products - Remote Controllers Reference
Details
PAC-YT51CRB
Simplified MA Remote Controller
Cost (£) 104
Reference
Details
PAR-30MAA
Deluxe MA Remote Controller with blue backlight display
Dimensions: 70x41x120 City Multi, Mr Slim and M Series (Via MAC-397IF interface)
Reference
Details Simplified ME Remote Controller
Dimensions: 120x19x120 City Multi, Mr Slim and M Series (Via MAC-397IF interface)
Cost (£) 104
Monitor: Setpoint, Fan speed, On/Off, Test run, Fault codes, Permit/prohibit and Setpoint limit (with MELANS) Control: Setpoint, Fan speed, On/Off
Reference
Details
PAR-W21MAA
MA Air to Water Remote Controller
Details
BS-51COV-B
Brushed Stainless Steel Cover
Dimensions: 130x19x120 City Multi (PWFY-P, VRF PHV2000 NT) and Mr Slim (PHV2000 NT)
Cost (£) 30
Reference
Details
PAR-F27MEA
ME Remote Controller
Details Polished Stainless Steel Cover
Reference PB-51COV-B
Page 106
Cost (£) 30
Reference
Details
PAR-FL32MA
Wireless Remote Controller Monitor: Setpoint, On/Off, Mode, Air flow, Lossnay, Test run, Fault codes, Permit/Prohibit Control: Setpoint, On/Off, Mode, Air flow, Lossnay, Test run, Daily Timer
Dimensions: 70x41x120
Dimensions: 157x18x57 City Multi and Mr Slim
Polished Brass Cover
75
Dimensions: 130x19x120 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Polished Stainless Steel Cover for PAC-SE51CRA / PAC-YT51CRB Mode button not available
Details
Cost (£)
Monitor: Setpoint, Fan speed, On/Off, Mode, Air flow, Lossnay, Test run, Fault codes, Permit/Prohibit, Return air temperature Control: Setpoint, Fan speed, On/Off, Mode, Air flow, Lossnay, Test run, Setpoint limit, Permit/Prohibit, Daily Timer
Dimensions: 70x41x120
Reference
120
Control: Setpoint, On/Off, Mode, Test run, Weekly Timer
Brushed Stainless Steel Cover for PAC-SE51CRA / PAC-YT51CRB Mode button not available
PS-51COV-B
Cost (£)
Monitor: Setpoint, On/Off, Mode, Test run, Fault codes, Water temperature
Dimensions: 70x41x120 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Reference
70
Monitor: Setpoint, Fan speed, On/Off, Mode, Air flow, Lossnay, Test run, Fault codes, Permit/Prohibit, Return air temperature, Maintenance function for Mr Slim units Control: Setpoint, Fan speed, On/Off, Mode, Air flow, Lossnay, Test run, Setpoint limit, Permit/Prohibit, Weekly Timer, Night set back, Energy saving, Silent mode and Run/Standby with Mr Slim
Monitor: Setpoint, Fan speed, On/Off, Mode, Test run, Fault codes Control: Setpoint, Fan speed, On/Off, Mode
PAC-SE51CRA
Cost (£)
Cost (£) 30
Reference
Details
PAR-FA32MA
Wireless Receiver
Polished Brass Cover for PAC-SE51CRA / PAC-YT51CRB Mode button not available
Monitor: Setpoint, On/Off, Mode, Air flow, Lossnay, Test run, Fault codes, Permit/Prohibit Control: Setpoint, On/Off, Mode, Air flow, Lossnay, Test run, Daily Timer
Dimensions: 70x41x120
Dimensions: 70x18x120 City Multi and Mr Slim
Cost (£) 34
Cost (£) 55
Page 107
Core Products - Centralised Controllers Reference
Details
AT50
AT50 Touch Screen Centralised Controller
Cost (£) 781
Reference
5” QVGA touch screen centralised controller with full control of up to 50 indoor units. Weekly timer, Night set back, Screen lock. This price only includes the AT50 Controller. Each AT50 Controller may require its own power supply PAC-SC51KUA (when used on more than one system).
Details AG150 Touch Screen Centralised Controller
Cost (£) 1375
9” wide touch screen centralised controller with full control of up to 50 indoor units. Refrigerant status check function. Internet connection with SSL security. Sliding temperature, night set back, optimised start, AutoCAD drawing display, screen lock, USB back-up and restore. Some functions may require a PAC-YG63MCA. Additional options using PIN Codes. Refer to PIN CODE ACTIVATION. Dimensions: 300x62x175 This only includes the AG150 Controller. Each AG150 Controller requires its own power supply PAC-SC51KUA. City Multi, Mr Slim and M Series (Via A2M Adaptor)
Reference
Details
PAC-YG50ECA
AG150 Expansion Controller
997
Dimensions: 250x97x266 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Dimensions: 180x30x120 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Reference
Cost (£)
Available March 2011 WebPages centralised controller (without keypad or display) with full control of up to 50 indoor units. Local remote controller can be enabled or disabled. Weekly timer, current alarm with alarm log, Annual Sheduling PIN Code included, Sliding temperature, Night set back, Optimised start. Some functions may require a PAC-YG63MCA.
Available April 2011
AG150 Controller
Details
GB50ADA Controller GB50ADA Centralised Controller
Reference
Details
PAC-SC51KUA
Power Supply
Cost (£) 220
The AG150 controller will be purchased with the PAC-SC51KUA power supply unit. Each AG150 requires its own power supply. Each power supply unit will require a 240VAC, 6 amp fused supply. Dimensions: 271x72x169 AG150 and AT50
Cost (£) 1011
The new PAC-YG50ECA expansion controller allows the AG150 to monitor and control up to 150 indoors units. 2 required for 51 to 100 indoor units. 3 required for 101 to 150 indoor units. Ethernet connection between AG150 and PAC-YG50ECA. Ethernet cables and hub not supplied by MEUK. Dimensions: 250x97x266 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Page 108
Page 109
Core Products - Interfaces Reference
Details
IO Interface
IO Interface
Details
PAC-SA89TA-E
3 Wire Adaptor
Details
MAC-397IF
Hardwired Remote Controller Interface
Cost (£) 51
Hardwired remote controller interface, On/Off or Fire Alarm input and Run or Fault output. PAC-YT51CRB and PAR-21MAA connectable.
Cost (£)
Dimensions: 160x55x70 M and S Series
160
Monitor and control: On/Off, remote Permit/Prohibit using volt free contact. Control: Remote controller Permit/Prohibit using volt free contact, Setpoint, Mode and Fan Speed using a DC voltage (0 to 10V DC). Monitor: Run, Faults, Heating/Cooling, Thermo On/Off. Relay may be closed or opened under run and fault conditions. Includes two energy saving functions: Auto mode for 0.5, 1 or 2 hours and Dual Setpoint. Dimensions: 85x32x138 Splits ONLY
Reference
Reference
Reference
Details
MAC-399IF
A2M Adaptor
Cost (£) 113
Converter to M-NET. Connect to indoor unit.
Cost (£)
Dimensions: 160x55x70 M and S Series
5
Control the indoor unit On/Off remotely. The On/Off remote controller button will be disabled. By pushing the button, the remote controller will display “Centrally controlled”. (Cable length < 1m) City Multi and Mr Slim
Reference
Details
PAC-SA88HA-EP
5 Wire Adaptor
Cost (£)
Reference
Details
ProconTM TCB1
ProconTM TCB1 Remote Interlock
Details 9 Wire Adaptor for AG150 / GB50ADA
Cost (£) 30
Monitor and control: Common On/Off. Monitor: Common Error Codes. A relay can be driven under common fault conditions (if one or more indoor units are in faults). Ability to connect to Fire Alarm system. 12V/24VDC required for inputs. (Cable length < 1m). Option 1: 12V / 24VDC: Units On but “Centrally Controlled”. 0V: Units Off Option 2: 12V / 24VDC: Units Off and “Centrally Controlled”. 0V: Normal conditions. City Multi, Mr Slim and M Series (Via A2M Adaptor)
Page 110
Ex-stock
Dimensions: 80x45x80 City Multi and Mr Slim
Using CN52: Monitor fan motor or thermostat, cooling / dry and heating (Cable length < 1m). CN51 / CN52 available with City Multi. CN51 only available with Mr Slim
PAC-YG10HA-E
Stock
45
Monitor and control: On/Off. The On/Off remote controller button will NOT be disabled. 12V DC power supply required.
9
Using CN51: Monitor and control the indoor unit On/Off remotely with pulse signal. Also, monitor Error Codes. A relay can be driven under fault conditions.
Reference
Cost (£)
Reference
Details
PAC-SF81MA
A2M Adaptor
Cost (£) 116
Converter to MNET. Connect to outdoor unit. Dimensions: 130x15x90 Mr Slim ONLY
Page 111
TG2000 Software Packages Reference
Details
PAC-SK82SI
Serial Adaptor
Cost (£) 72
Reference
Details
TG2000-Software
TG2000 Software
Interface for A32M. Connect to outdoor unit.
Cost (£)
Stock
FOC
4-weeks
Control up to 40 x AG150/GB50ADA’s i.e. 2000 indoor units via graphical interface (building specific with AutoCAD drawing). As standard: centralised function, setpoint limit, trend logging, night mode.
Dimensions: 130x15x90 Mr Slim ONLY
With PIN Codes: Energy charging, Energy saving, Load shedding. With MNET Interface: Control and monitor general equipment. FOC = Free of Charge
Reference
Details
PAC-YG60MCA
Pulse Energy Meters (x4) MNET Interface
Reference
Details
TG2000-Graphic
One graphical page for TG2000
Cost (£)
Monitor up to 4 energy pulse meters for air conditioning or third party equipment energy monitoring. AG150/GB50, TG2000 and G50-EC-Full required for full energy monitoring. AG150/GB50 and G50-PC-Full required for load shedding. Interface connected on MNET. 24VDC power supply required.
Reference
Details
PAC-YG66DCA
Third Party Equipment Digital MNET Interface (On/Off, Run, Faults)
Stock
150
4-weeks
The complete system configuration can be allocated between multiple screens in TG2000. Each screen can display a bitmap image representing the area of the building or floor where the units or groups are physically located. One graphical page would represent an area of the building or a floor. A maximum of 30 indoor units can be allocated to one graphical page (screen).
300
Dimensions: 200x45x120 AG150, AT50 and GB50ADA
Cost (£)
AutoCAD drawing must be sent 2 weeks prior to site visit.
AG150 Panel and Cover Options Cost (£)
Reference
Details
PAC-YG83UTB
AG150 Back Box
Stock
60
4-weeks
Metal back box for the AG150. The PAC-SC51KUA power supply cannot be installed inside the PAC-YG83UTB.
300
Monitor and control up to 2 pieces of general equipment using the AG150/GB50 Web browser or TG2000. Interlocking available (contact sales offices for more details). Interface connected on MNET. Volt free contact signals for input and output. 24VDC power supply required. Dimensions: 200x45x120 AG150, AT50 and GB50ADA
Cost (£)
Dimensions: 346x60x220
Reference
Details
PAC-YG81TB
AG150 Wall Mounted Box
Cost (£)
Stock
72
4-weeks
Plastic wall mounted box for the AG150. The PAC-SC51KUA power supply cannot be installed inside the PAC-YG81TB.
Reference
Details
PAC-YG63MCA
Third Party Equipment Analogue MNET Interface (Temperature. Humidity)
300
Monitor one temperature and one humidity sensor (4-20mA, 1-5V, 0-10V, PT100) using the AG150/GB50 Web browser or TG2000. Interlocking available (contact sales offices for more details). High / low humidity and temperature alarms available via volt free contact and Email. Interface connected on MNET. 24VDC power supply required. Dimensions: 200x45x120 AG150, AT50 and GB50ADA
Page 112
Dimensions: 299x65x184
Cost (£) Reference
Details
PAC-YG85KTB
AG150 Panel
Cost (£)
Stock
90
4-weeks
Plastic panel for the AG150 and the PAC-SC51KUA. The top of the panel is used for the AG150 and the bottom for the PAC-SC51KUA power supply.
Dimensions: 299x101x399
Page 113
Reference
Details
PAC-YG71CBL
AG150 Black Cover
Cost (£)
Stock
72
4-weeks
Details Energy Charge (TG2000) [per G50/GB50]
Cost (£)
Stock
258
2-weeks
Optional black cover for AG150.
Energy Charge. TG2000 required. Able to generate bills for individual indoor units, group of indoor units or complete system. Able to export the bills to Microsoft Excel using CSV file.
Dimensions: 300x20x175
PAC-YG60MCA required with energy meters.
G50/GB50/AG150 Software Options Pin Code Activation Reference
Reference G50-EC-Full
Details
G50-Web Monitor G50-Web Monitor (WebPages) [per G50/GB50]
Cost (£)
Stock
FOC
2-weeks
Monitor and control the G50/GB50 using a web browser. Connect the PC directly to G50/GB50 using a CROSS OVER cable or with a hub using standard computer network cables. Network cables and hubs not supplied by Mitsubishi Electric.
Reference
Details
G50-ES-Full-Opt1 G50-ES-Full-Opt2 G50-ES-Full-Opt3
Energy Saving (TG2000) for up to 20 units [per G50/GB50] Energy Saving (TG2000) for up to 35 units [per G50/GB50] Energy Saving (TG2000) for up to 50 units [per G50/GB50]
Details
G50-E-mail
G50-E-mail (WebPages) [per G50/GB50]
Cost (£)
Stock
FOC
2-weeks
Enable Email activation on fault conditions. 10 different Emails can be set-up. Faults can be filtered and redirected to specific Emails. When the fault occurs, one Email will be sent. Another Email will be sent when the fault has been cleared.
Stock
217 340 423
2-weeks
Cost (£)
Stock
217 340 464
2-weeks
TG2000 required. 4 different options of Energy Saving (control time configurable): - Indoor unit: Setpoint ±2 to 9°C, fan only, unit off - Outdoor unit: De-rate capacity outdoor to 90, 80, 70, 60%
Reference
Details
G50-PC-Full-Opt1 G50-PC-Full-Opt2 G50-PC-Full-Opt3
Load shedding (TG2000) for up to 20 units [per G50/GB50] Load shedding (TG2000) for up to 35 units [per G50/GB50] Load shedding (TG2000) for up to 50 units [per G50/GB50] PAC-YG60MCA required with energy meters.
FOC = Free of Charge
Reference
Cost (£)
4 different levels of maximum limit can be set-up to which energy saving options can be enabled.
Reference
Details
G50-VRC-Full-Opt1 G50-VRC-Full-Opt2 G50-VRC-Full-Opt3
V.R.C. (WebPages) for up to 20 units [per G50/GB50] V.R.C. (WebPages) for up to 35 units [per G50/GB50] V.R.C. (WebPages) for up to 50 units [per G50/GB50]
Cost (£)
Stock
309 433 773
2-weeks
V.R.C.: Virtual Remote Controller FOC = Free of Charge
Able to set-up 50 different usernames and passwords. Units can be allocated to individual users.
Reference
Details
G50-AS-Full
Annual Scheduling (WebPages) [per G50/GB50]
Cost (£)
Stock
FOC
2-weeks
Annual Scheduling with Night Set Back available from WebPages (PC) Able to set the setpoint temperature down to 12°C with Night Set Back at any time of the day.
Reference
Details
PAR-21PC
Remote Controller Software
Cost (£) FOC
Remote controller software interface to be installed on computer. Allows customer to control and monitor up to 16 indoor units (within one group). PIN Code required for each PC. FOC = Free of Charge
Page 114
FOC = Free of Charge
Page 115
Reference
Details
AG150 - Basic
AG150 Web Monitoring, Email and Annual scheduling [per AG150]
Cost (£)
Stock
FOC
2-weeks
Monitor and control the AG150 using a Web browser. Email can be sent under fault conditions using SSL security. Annual scheduling available.
BEMS Core Products Reference
Details
MOD-IP/50
ProconTM MODBUS-IP/50 Interface
Reference
Details AG150 Energy Charge, Energy Saving and Load Shedding [per AG150]
Cost (£)
Stock
463
2-weeks
Stock
1541
4-weeks
Modbus Interface. 50 Indoor units max. Cost does not include commissioning. Monitor and control: On/Off, Mode, Fan speed, Setpoint Monitor: Error Code and Return air temperature Dimensions: 144x34x104 City Multi, Mr Slim and M Series (Via A2M Adaptor, AG150 or GB50ADA)
FOC = Free of Charge
AG150 - Energy
Cost (£)
Energy monitoring function available from the AG150 centralised controller. Energy saving features as well as Load shedding can be activated to reduce energy consumption. Energy meters and PAC-YG60MCA required for Energy monitoring and Load shedding.
Reference
Details
AG150 - VRC
V.R.C. (WebPages) for up to 50 units [per AG150]
Cost (£)
Stock
156
2-weeks
Reference
Details
ProconTM A32M
ProconTM A32M Modbus Interface
Details
AG150 - INTERLOCK AG150 Interlock
Reference
Details GB50ADA Web Monitoring, Email and Annual scheduling [per GB50ADA]
4-weeks
Monitor and control: On/Off, Mode, Fan speed, Setpoint Monitor: Error Code and Return air temperature Dimensions: 270x75x210 Mr Slim ONLY (Via PAC-SK82SI Adaptor)
Cost (£)
Stock
210
2-weeks
The interlock function is used to interlock inputs (software or hardware) with outputs (software or hardware). Up to 150 interlock functions can be set-up using the WebPages. 3 or 5 wire adaptors will be required to connect to each indoor unit.
GB50ADA - Basic
Stock
994
Modbus Interface. 32 outdoor units max. Modbus to Trend interface SXNC200 available (Not supplied by MEUK). Cost does not include commissioning. PAC-SK82SI required per outdoor unit.
V.R.C. Virtual Remote Controller. Able to set-up 50 different user names and passwords. Units can be allocated to individual users.
Reference
Cost (£)
Cost (£)
Stock
FOC
2-weeks
Reference
Details
ProconTM A1M
ProconTM A1M Modbus Interface
Cost (£)
Stock
76
4-weeks
Modbus Interface. 1 indoor unit max. Cost does not include commissioning. Monitor and control: On/Off, Mode, Fan speed, Setpoint Monitor: Error Code and Return air temperature Dimensions: 72x27x50 Mr Slim (inc Air Curtains) and M Series
Monitor and control the GB50ADA using a Web browser. Email can be sent under fault conditions using SSL security. Annual scheduling available.
FOC = Free of Charge
Page 116
Page 117
Reference
Details
ProconTM BAC-IP/50 ProconTM BAC-IP/50 BACnet® Interface
Cost (£)
Stock
1833
4-weeks
Reference
Details
ProconTM KNX-EIB-IP-100 ProconTM KNX-EIB-IP-100 KNX Interface
Cost (£)
Stock
2793
4-weeks
50 indoor units max. Cost does not include commissioning.
100 indoor units max. DIN Rail Mounted. Cost does not include commissioning.
Monitor and control: On/Off, Mode, Setpoint, Fan speed, Permit / Prohibit, Louver, Filter sign Monitor: Error Code, Return air temperature
Monitor and control: On/Off, Mode, Setpoint, Fan speed, Permit / Prohibit, Louver, Filter sign Monitor: Error Code, Return air temperature
Dimensions: 144x34x104 City Multi, Mr Slim and M Series (Via A2M Adaptor, AG150 or GB50ADA)
Reference
Details
BAC-HD150
BAC-HD150 BACnet® Interface
Dimensions: 107x58x105 City Multi, Mr Slim and M Series (Via A2M Adaptor, AG150 or GB50ADA)
Cost (£)
Stock
1725
4-weeks
Reference
Details
ProconTM KNX-EIB-A-1
ProconTM KNX-EIB-A-1 KNX Interface
Cost (£)
Stock
219
4-weeks
One indoor unit max. Connect to indoor unit. Cost does not include commissioning. 50 indoor units max. Cost does not include commissioning.
Monitor and control: On/Off, Mode, Setpoint, Fan speed Monitor: Error Code, Return air temperature
Monitor and control: On/Off, Mode, Setpoint, Fan speed, Permit / Prohibit, Louver, Filter sign Monitor: Error Code, Return air temperature
Dimensions: 60x28x45 Mr Slim and M series
Dimensions: 250x97x266 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Reference
Details
ProconTM BAC-A/50
ProconTM BAC-A/50 BACnet® Interface
Cost (£)
Stock
988
4-weeks
Reference
Details
LMAP
LMAP LonWorks® Interface
Cost (£)
Stock
1084
4-weeks
LonWorks® Interface. 50 indoor units max. AG150 optional. Cost does not include commissioning. 50 indoor units max. PAC-SK82SI required for each Mr Slim outdoor. Cost does not include commissioning.
Monitor and control: On/Off, Mode, Setpoint, Fan speed, Permit / Prohibit, Louver, Filter sign Monitor: Error Code, Return air temperature, Thermo
Monitor and control: On/Off, Mode, Setpoint, Fan speed, Permit / Prohibit, Louver, Filter sign Monitor: Error Code, Return air temperature
Dimensions: 340x360x60 City Multi, Mr Slim and M Series (Via A2M Adaptor)
Dimensions: 270x75x210 Mr Slim ONLY (Via PAC-SK82SI Adaptor)
Reference Reference
Details
ProconTM KNX-EIB-IP-15 ProconTM KNX-EIB-IP-15 KNX Interface
Cost (£)
Stock
1479
4-weeks
15 indoor units max. DIN Rail Mounted. Cost does not include commissioning. Monitor and control: On/Off, Mode, Setpoint, Fan speed, Permit / Prohibit, Louver, Filter sign Monitor: Error Code, Return air temperature Dimensions: 107x58x105 City Multi, Mr Slim and M Series (Via A2M Adaptor, AG150 or GB50ADA)
Page 118
Details
ProconTM MELCOTELTM ProconTM MELCOTELTM Hotel Interface
Cost (£)
Stock
1412
4-weeks
Control and monitor up to five AG150/GB50. 250 Indoor units max. Cost does not include commissioning. Works with and without a key card system. 3 Wire Adaptor (PAC-SA89TA-E) required for each indoor unit. Monitor and control: Occupied settings reset, automatic switch OFF, setback control, night-time OFF, night-time setpoint offset, window open control, outside temperature adjustment, remote monitoring with Mini M2M Software available: Configuration Manager to set up the Melcotel and Live Status to monitor all the settings Dimensions: 300x70x350 City Multi ONLY (Via AG150 or GB50ADA)
Page 119
Run Standby Panel
Procon M2M TM
Reference
Details
M2M-IP/50
ProconTM Maxi M2M-IP/50
Cost (£)
Stock
1301
4-weeks
Details
Cost (£)
Stock
ProconTM PANEL_RS_SMS ProconTM Run Standby Panel
Reference
644
4-weeks
The panel PANEL_RS_SMS replaces the previous run standby panels. The new panel is smaller and uses Micro M2M technology. The panel can control up to 8 indoor units and will send a text message under fault condition. The PANEL_RS_SMS is pre-configured as a PANEL_RS1 and can be re-configured as PANEL_RS2 or PANEL_RS3 using a jumper. For more than two units, one ProconTM A1M needs to be purchased per additional unit. Fault output using volt free contact.
Machine 2 Machine GPRS interface. 50 indoor units max. Max of 1 x AG150/GB50 required. 22 analogue or digital inputs. 16 digital outputs. Cost includes one year server hosting and one year SIM card subscription. Monitor and control up to 25 groups: On/Off, Mode, Fan Speed, Setpoint, Permit/Prohibit, Louver, Filter sign Monitor and control up to 50 groups: On/Off, Mode, Setpoint Monitor: Error Code and Return air temperature Dimensions: 300x70x350 City Multi, Mr Slim and M Series (Via A2M Adaptor, AG150 or GB50ADA)
Reference
Details
M2M-A/16
ProconTM Mini M2M-A/16
Cost (£)
Stock
771
4-weeks
Machine 2 Machine GPRS interface. 16 indoor units max. For more than one unit, one ProconTM A1M needs to be purchased per additional unit. 8 analogue or digital inputs. 4 digital outputs. Cost includes one year server hosting and one year SIM card subscription. Monitor and control: On/Off, Mode, Fan Speed, Setpoint Monitor: Error Code and Return air temperature Dimensions: 255x60x180 Mr Slim and M Series (via ProconTM A1M)
Dimensions: 253x90x180 Mr Slim and M Series (via Procon A1M)
Commissioning Reference
Details
TG2000-Com-Opt1
TG2000 Commissioning - up to 100 units
Cost (£)
Stock
464
2-weeks
The TG2000 commissioning option allows for complete commissioning and testing of the TG2000, AG150 / GB50ADA (x2) and each WORKING A/C system plus the activation of any additional TG2000 software function. Please note that for each additional TG2000 software function to work, the associated AG150 / GB50ADA controllers must have had appropriate PIN code(s) activated.
Reference
Details
M2M-SMS-A/08
ProconTM Micro M2M-SMS-A/08
Cost (£)
Stock
390
4-weeks
Machine 2 Machine SMS interface. 8 indoor units max. For more than one unit, one ProconTM A1M needs to be purchased per additional unit. Micro M2M cannot be connected to the M2M server. Monitor and control: On/Off, Mode, Fan Speed, Setpoint, Back-up & Rotate Monitor: Error Code, Return air temperature and High temperature alarm Dimensions: 70x51x105 Mr Slim and M Series (via ProconTM A1M)
Page 120
Reference
Details
TG2000-Com-Opt2
TG2000 Commissioning - up to 200 units
Cost (£)
Stock
927
4-weeks
The TG2000 commissioning option allows for complete commissioning and testing of the TG2000, AG150 / GB50ADA (x4) and each WORKING A/C system plus the activation of any additional TG2000 software function. Please note that for each additional TG2000 software function to work, the associated AG150 / GB50ADA controllers must have had appropriate PIN code(s) activated.
Page 121
Mitsubishi Electric Partner Programme Open to all contractors - large or small - the Mitsubishi Electric Partner Programme offers contractors a totally new and unique set of benefits. There are two categories within the programme - Accredited Installer and Business Solutions Partner. These levels are a straight-forward reflection of the Partner’s stage of growth. All customers signing up to the programme standards are committing to continued training and professional development.
For more information please contact your local sales office
Mitsubishi Electric Training Options Mitsubishi Electric has four state-of-the-art training suites based at different locations around the country for your convenience. Providing training for all levels of expertise, our courses are taught by experienced engineers, with a wealth of knowledge and are all CPD accredited.
For bookings please telephone 0161 866 6089
Many of our systems have an energy label of A. These systems meet the criteria of the Energy Technology List and hence could qualify for 100% first year enhanced capital allowances (whole system cost and ‘reasonable’ cost of installation). For further information please go to www.eca.gov.uk
Nominal Conditions: Cooling; indoor 27˚C DB, 19˚C WB; outdoor 35˚C DB, 24˚C WB. Nominal Conditions: Heating; indoor 20˚C DB; outdoor 7˚C DB, 6˚C WB. UK Conditions: Summer; indoor 21˚C DB, 15˚C WB; outdoor 27˚C DB. UK Conditions: Winter; indoor 21˚C DB; outdoor -1˚C WB.
Note: The fuse rating is only a typical value, it is the responsibility of a qualified electrician/electrical engineer to select the correct cable size and fuse rating based on current regulation and site specific conditions.
Domestic Heating Photovoltaics Air Conditioning Commercial Heating
Effective as of 1st March 2011
Price List 2011 Air Conditioning
Difference Wo r l d o f Making a The Renewable Solutions Provider
The Renewable Solutions Provider
Making a World of Difference 2011 Air Conditioning Price List After Sales Service: 0161 866 6089 email: air.conditioning@meuk.mee.com web: www.mitsubishielectric.co.uk/aircon UNITED KINGDOM Mitsubishi Electric Europe Living Environmental Systems Division Travellers Lane, Hatfield, Hertfordshire, AL10 8XB, England General Enquiries Telephone: 01707 282880 Fax: 01707 278881 IRELAND Mitsubishi Electric Europe Westgate Business Park, Ballymount, Dublin 24, Ireland Telephone: Dublin (01) 419 8800 Fax: Dublin (01) 419 8890 International code: (003531) Country of origin: United Kingdom – Japan – Thailand – Malaysia. ©Mitsubishi Electric Europe 2011. Mitsubishi and Mitsubishi Electric are trademarks of Mitsubishi Electric Europe B.V. The company reserves the right to make any variation in technical specification to the equipment described, or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. Third-party product and brand names may be trademarks or registered trademarks of their respective owners.
Printed in November 2010
SAP No. 238469
Designed by Square Bear Limited 01604 899099. Square Bear Limited are committed to using FSC certified paper and printers, wherever possible. The sealant process used on this catalogue is environmentally friendly, recyclable and biodegradable.
2011 Air Conditioning Price List
Telephone: 01707 282880
Effective as of 1st March 2011
Air Conditioning Commercial Heating Domestic Heating Photovoltaics