CELINE POWER INTERNATIONAL S.L.
CELINE POWER INTERNATIONAL S.L. Plaza Sierra Castilla 33 03177 San Fulgencio-Spain www.celine-photovoltaic-power.com info@celine-power.com
Plug & Save: Connect it and Save. It is that simple to convert sunlight into electricity, with the first worldwide mobile solar system with integrated energy storage from Sun Invention. Electricity flows directly from the solar panel into your socket and can reduce the electricity bill by approximately 25 per cent. You simply plug the outgoing power cable of the system into a socket. Several panels can be connected in between each other. In addition, the integrated energy storage ensures that electricity produced during the day is available at night. Whether you are a tenant or an owner – you will always find a sunny place for the panels in the garden, on the terrace or the roof, on the façade or on the balcony. The corresponding mounting accessories are part of the complete system, with three years guarantee.
Model Optimus (PS195mS1.3), with integrated energy storage:
Model Light (PS195oS1.3) & Basic (PS195BASIC), without energy storage:
Dimensions: 808mm x 1580mm x 60mm (W x H x D), double wall aluminium frame
Dimensions: 808mm x 1580mm x 60mm (W x H x D), double wall aluminium frame
Solar Panel: Pmax 195 W Voc 45,52 V lsc 5,58 A Vmpp 37,44 V lmpp 5,21 A
Panel: Pmax Voc lsc Vmpp lmpp
Inverter: V-DC mpp V-OC l-DC max V-AC nom f-AC nom P-AC nom l-AC nom Efficiency
24-40 V 50 V 10,4 A 184-264 V 47-51 Hz 235 W 1,07 A 95,2%
195 W 45,52 V 5,58 A 37,44 V 5,21 A
Inverter (only included in Light version): V-DC mpp 24-40 V V-OC 50 V l-DC max 10,4 A V-AC nom 184-264 V f-AC nom 47-51 Hz P-AC nom 235 W l-AC nom 1,07 A Efficiency 95,2%
Energy Storage: Lithium-Ion batteries Block 8 batteries with BMS 8 x 3,2 V/15 Ah Charge 430 Wh Discharge 250 Wh
Manufacturer warranty: Complete system: 3 years Solar panel: 10 years Inverter: 10 years (only included in light version) Performance warranty 80% Pmax (panel): 25 years
Manufacturer warranty: Complete system: 3 years Solar panel: 10 years Inverter: 10 years Performance warranty 80% Pmax (panel): 25 years
Protection class IP65 EN 50438 - ENEL - UL1741 - CQC VDE0126-1-1 - IEEE1547 - AS4777 EN 62109 - IEC 62109-1/-2 - SEMKO
Performance curve Model Optimus, Light as well as Basic at 20º inclination TRI-KA Measuring Messung 1
Start measuring: 21.08.201210:50:01 10:50:01 Messung Start:21.08.2012
End measuring: 21.08.2012 10:50:13 10:50:13 Messung Ende:21.08.2012
Power [W]
Current [A]
Client: Balcony module / Installation: Installation 1 / Inverter: Inverter 1 / String:1 String 1 String 1 Kunde: Balkon Modul / Anlage: Anlage 1 / Wechselrichter: Wechselrichter / String:
Temperatur Measured == gemessen temperature
32,3 °C
Measured == Bestrahlung radiation gemessen
720 W/m²
Measured= = Neigung inclination gemessen
20 °
ISC Roh = ISC STC = ISC NOM =
4,225 A 5,87 A 5,58 A
IMPP Roh = IMPP STC = IMPP NOM =
3,666 A 5,09 A 5,24 A
UOC Roh = UOC STC = UOC NOM =
42,58 V 44,66 V 45,4 V
UMPP Roh = UMPP STC = UMPP NOM =
34,35 V 36,44 V 37,2 V
P Roh = P STC = P NOM =
125,9 W 185,5 W 195 W
FF Roh = FF STC = FF NOM =
0,70 0,71 0,77
Voltage [V]
21.08.2012 11:07
Performance curve Model Optimus, Light as well as Basic at 70º inclination TRI-KA Measuring Messung 11
Messung Start:21.08.2012 Start measuring: 21.08.201210:53:02 10:53:02
Messung Ende:21.08.2012 End measuring: 21.08.2012 10:53:16 10:53:16
Power [W]
Current [A]
Kunde: Balkon Modul / Anlage: Anlage 1 / Wechselrichter: Wechselrichter / String: String 2 70° Client: Balcony module / Installation: Installation 1 / Inverter: Inverter 1 / String:1 String 2 70°
Voltage [V]
21.08.2012 11:09
Temperatur Measured == gemessen temperature
29,4 °C
Measured == Bestrahlung gemessen radiation
790 W/m²
Measured= = Neigung inclination gemessen
66 °
ISC Roh = ISC STC = ISC NOM =
4,239 A 5,37 A 5,58 A
IMPP Roh = IMPP STC = IMPP NOM =
3,909 A 4,95 A 5,24 A
UOC Roh = UOC STC = UOC NOM =
41,59 V 42,91 V 45,4 V
UMPP Roh = UMPP STC = UMPP NOM =
33,25 V 34,57 V 37,2 V
P Roh = P STC = P NOM =
130 W 171,1 W 195 W
FF Roh = FF STC = FF NOM =
0,74 0,74 0,77
CELINE POWER INTERNATIONAL S.L. Plaza Sierra Castilla 33 03177 San Fulgencio-Spain www.celine-photovoltaic-power.com info@celine-power.com