Health & Wellness Internship

Page 1

CHARLIE LAUBERTH SUMMER/FALL 2016 ARCH 807


SSM St. Mary’s Witte Building 818 Euclid Renewal Shriner’s Hospital Renewal

JUNE

JULY

AUGUST

SEPTEMBER


City Foundry John Burrough’s

OCTOBER

NOVEMBER

DECEMBER

JANUARY


SHRINER’S HOSPITAL RENEWAL WASHINGTON UNIVERSITY STUDENT HOUSING

Washington University in Saint Louis is converting the original Shriner’s Hospital near Forest Park into graduate student housing. I joined the project during the transition from the design development to the construction document phase. I had responsibilities in editing partition types, drawing exterior details, and conducting site verification.

GENERAL PLAN NOTES

KEYNOTES 214

NEW STEEL GUARDRAIL - 42" HIGH PREFINISHED LATTICE STYLE WITH VERTICAL MOUNTING BRACKETS AT 6' O.C. MOUNT GUARDRAIL TO FACE OF EXISTING CONCRETE WALL, SEE STRUCT FOR DETAIL. PAINT. NEW 10'H TRASH ENCLOSURE WITH STEEL SLAT GATES. FULL BRICK MASONRY CLADDING OVER 8" CMU REINFORCED AND FULLY GROUTED. CAST STONE CAP. SEE SITE DETAILS FOR MORE INFORMATION. NEW DECORATIVE ALUMINUM GUARDRAIL. 42"H WITH VERTICAL PICKETS AT 4" O.C. EMBED NON-CORROSIVE SLEEVE 6" INTO TOP OF WALL AT SUPPORT POSTS.

233

AA

BB

CC

DD

EE

FF

GG

HH

II

JJ

238

KK

C:\Users\cpinkley12\Documents\14260_Shriners_wksh_v16_cpinkley12.rvt

B1 B2

C D

G H I

Storage 1003 UNIT "I" REVERSED 123

UNIT "I" REVERSED 121

DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ALL DIMENSIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES FOUND AMONG THE DOCUMENTS OR BETWEEN THE DOCUMENTS AND EXISTING CONDITIONS. ALL DIMENSIONS ARE TO FINISH FACE OF PARTITION OR FACE OF EXISTING WALL U.N.O. SEE PARTITION TYPES SHEETS FOR BALANCE OF INFORMATION. CONSTRUCT RATED ASSEMBLIES COMPLETE AND UNINTERRUPTED FROM THE CONSTRUCTION OF NON-RATED ASSEMBLIES. FLOOR PENETRATIONS AND WALL PENETRATIONS SHALL BE U.L. TESTED AND APPROVED FIRESTOP SYSTEM AT ALL NEW AND EXISTING RATED FLOOR AND RATED WALL PENETRATIONS, INCLUDING THOSE REVEALED DURING DEMOLITION. ALL EXPOSED CONDUIT OR PIPE TO BE PAINTED TO MATCH ADJACENT WALL. AT ALL EXISTING PLASTER WALL AND CEILING SURFACES TO REMAIN, ADD SKIM COAT OF NEW PLASTER TO MATCH ORIGINAL PLASTER TEXTURE. PREP FOR NEW FINISH. SEE DEMOLITION AND STRUCTURAL DRAWINGS FOR ALL FLOOR REPAIR/INFILL. SEE ENLARGED PLAN SHEETS FOR ADDITIONAL PARTITION TYPES, NOTES, AND DIMENSIONS. SEE MEP DRAWINGS FOR BALANCE OF PLAN INFORMATION.

B

E F

1 A202

Elec/Data 1004

A

UNIT "I" 124

UNIT "I" REVERSED 125

UNIT "I" 126

Bath 55 SF

Austin Carolinas New York St. Louis Office:

319 North 4th Street Suite 1000 St. Louis, MO 63102 p (314) 231-5700 f (314) 231-0816

Project Team: DFC Group, Inc 7777 Bonhomme Ave, Suite 1210 St. Louis MO 63105 p: (314) 725.8555 f: (314) 725.8855 Lawrence Group 319 North 4th Street, Suite 1000 St. Louis MO 63102 p: (314) 231.5700 f: (314) 231.0816 KPFF Consulting Engineers, Inc. 1630 Des Peres Road, Suite 100 St. Louis MO 63131 p: (314) 835.0524 f: (314) 835.0749

Owner Representative:

B3

Architect: W/D

W/D

Stair 4 S 4-1

DN

W/D

Structural Engineer: DW

1003

UP

REF. REF.

DW

DW

IR-128

Corridor 1001

DW

REF.

DW

REF.

S3.1

DW

J-127

REF.

I-129

IR-119

I-120

DW

REF.

UP W/D

W/D

W/D

DW

Civil Engineer:

Stock & Associates Consulting Engineers 257 Chesterfield Business Parkway Chesterfield, MO 63005 p: (636) 530.9100 f: (636) 530.9130

MEPF Engineer:

Horner & Shifrin, Inc. #401 S. 18th Street, Suite 400 St. Louis MO 63103 p: (314) 335.8621 f: (314) 531.6966

DN REF.

W/D

238

Sim

1 A501.1

ALIGN

B5

11/18/2016 9:58:15 AM

REF.

DW

I-126

REF.

1004

1001

I-124

IR-121

DW

IR-123

REF.

B4

W/D

W/D

IR-125

238

W/D

1002

Professional Seal:

B6 B7 238

UNIT "I" 120

UNIT "I" REVERSED 119

238

UNIT "I" REVERSED 128

UNIT "I" 129

238

238

UNIT "J" 127

Stair 3 S3-1

2 A202

4 A203

Project Title:

1

Sim

A501.2

1.0

1005A

DW

F-114

W/D

W/D

UNIT "F" 114

REF.

UNIT "C" REVERSED 118

2.0 DW

UNIT "A" 113

W/D

3 A202

214

DR-117

W/D

UNIT "D" REVERSED 117

4.0 REF.

W/D

Corridor 1005

PROJECT DESCRIPTION

DW

UNIT "A" REVERSED 112 2 A203

ER-116

UNIT "E" REVERSED 116

AR-112

REF. DW

D

6.0

214

DW REF. 214

A-111

W

214

KEYNOTES

UNIT "A" 111

W/D

233 C-115

UNIT "A" REVERSED 110

W/D W/D

214

319 North 4th Street Suite 1000 St. Louis, MO 63102 p (314) 231-5700 f (314) 231-0816

DFC Group, Inc 7777 Bonhomme Ave, Suite 1210 St. Louis MO 63105 p: (314) 725.8555 f: (314) 725.8855 Lawrence Group 319 North 4th Street, Suite 1000 St. Louis MO 63102 p: (314) 231.5700 f: (314) 231.0816 KPFF Consulting Engineers, Inc. 1630 Des Peres Road, Suite 100 St. Louis MO 63131 p: (314) 835.0524 f: (314) 835.0749

KEY PLAN 1

14

Unisex 1022

E-108

AD15

W/D REF.

1021A

Admis. 15 AD 15

AD12

Admis. 12 AD 12

20

6 A203

DW

AD16

Corridor 1023

1020B

AD14

Admis. Lounge 1024

DW

CR-109

C-106

AR-102

UP

AD17 1022

Janitor Closet 1021

REF.

DN

REF.

DW

16

W/D

Project Title:

Admis. 16 AD 16

Admis. 17 AD 17

1027A

Corridor 1020C 1021

Corridor Corridor 1020 967 SF REF.

V

Sim

19

DW

W/D

15

W/D

REF.

1019

REF.

REF.

Stair 2 S2-1 S2-1B

U

DW

Elev.

S2-1A

W/D

Mail Room 1013

1 A501.5

REF.

UP

W/D

1011

Conference Room 1011

DW

DW

W/D

DW

Office 1010

UNIT "B" 105

18 REF.

DW

1007A

DN

Sim

UP

Adm. 11 a Elec/Dat 1019

1010

UNIT "A" REVERSED 104

UNIT "A" 103

AR-104

Admis. 11 AD 11

1007B

Entry 1007

S

5 AS200

214

UNIT "A" REVERSED 102

UNIT "A" 101

A-103

W

RE F. D

Admis. 10 AD 10

Stock & Associates Consulting Engineers 257 Chesterfield Business Parkway Chesterfield, MO 63005 p: (636) 530.9100 f: (636) 530.9130 Horner & Shifrin, Inc. #401 S. 18th Street, Suite 400 St. Louis MO 63103 p: (314) 335.8621 f: (314) 531.6966

Sim

DN

1017

Civil Engineer:

MEPF Engineer:

Professional Seal:

Admis. 9 AD 9

13 AD10

Issue Date:

214

214

1009B

AD11

Author

A501.4

12

D-107

AD09

Unisex ADA Restroom 1017

A101.1

Drawn By:

11/03/2016

Admis. 8 AD 8

Lounge 1008

Sheet Number:

14260

1020C

AD04

Project Number:

11

B-105

AD01

UP

Structural Engineer:

First Floor Plan

214

Admis. 7 AD 7

AD08

Main Lobby 1009

Architect:

10

AD06

1012

UP

T

Office:

Project Team:

Sheet Title:

Admis. 6 AD 6

AD05

Admissions Lounge 1014 AD07

Storage 1012

S1-1B

Admis. 4 AD 4

Admis. 3 AD 3

Admis. 2 AD 2

Admis. 1 AD 1

D

Stair 1 S1-1

AD03

Shaft Shaft 121 121

C

Austin Carolinas New York St. Louis

Owner Representative:

S1-1A

B

Sim

Admis. 5 AD 5

Adm. 1

AD02

1006 1006

3 A201

1 A501.3

1009A

1/8" = 1'-0"

1004B

214

J

214

9

Elec./Data Elec./Data 1006 1006

1004B

214

DW DW

DN

A101.1

REF. REF.

H

G

F

E

AR-110

11/18/2016 9:58:25 AM

Admis. 13 AD13 AD 13

Admis. 14 AD 14

W D

21

W/D

W 17 X

UNIT "C" 106 UNIT "D" 107 UNIT "E" 108 (ADA)

R

UNIT "C" REVERSED Suite 109

L K

M

N

O

P

Q

PROJECT DESCRIPTION

LGA2.5

1 First Floor Plan

A

C:\Users\cpinkley12\Documents\14260_Shriners_wksh_v16_cpinkley12.rvt

8.0

214

W/D W/D

DW DW

REF. REF.

UNIT "C" 115

GENERAL PLAN NOTES

The Professional Architect's seal affixed to this sheet NEW STEEL GUARDRAIL - 42" HIGH PREFINISHED LATTICE STYLE WITH VERTICAL MOUNTING A DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. CONTRACTOR TO FIELD VERIFY applies only to the material and items shown on this BRACKETS AT 6' O.C. MOUNT GUARDRAIL TO FACE OF EXISTING CONCRETE WALL, SEE STRUCT FOR EXISTING CONDITIONS AND ALL DIMENSIONS. NOTIFY ARCHITECT OF ANY DISCREPANCIES FOUND sheet. All drawings, instruments or other documents not DETAIL. PAINT. AMONG THE DOCUMENTS OR BETWEEN THE DOCUMENTS AND EXISTING CONDITIONS. exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims B any ALL DIMENSIONS ARE TO FINISH FACE OF PARTITION OR FACE OF EXISTING WALL U.N.O. SEE and all responsibility for such plans, drawings or PARTITION TYPES SHEETS FOR BALANCE OF INFORMATION. documents not exhibiting this seal. C CONSTRUCT RATED ASSEMBLIES COMPLETE AND UNINTERRUPTED FROM THE CONSTRUCTION OF NON-RATED ASSEMBLIES. This drawing and details on it are the sole property D of the FLOOR PENETRATIONS AND WALL PENETRATIONS SHALL BE U.L. TESTED AND APPROVED FIRESTOP architect and may be used for this specific project only. It SYSTEM AT ALL NEW AND EXISTING RATED FLOOR AND RATED WALL PENETRATIONS, INCLUDING shall not be loaned, copied or reproduced, in whole or THOSE REVEALED DURING DEMOLITION. part, or for any other purpose or project without the E ALL EXPOSED CONDUIT OR PIPE TO BE PAINTED TO MATCH ADJACENT WALL. written consent of the architect. F AT ALL EXISTING PLASTER WALL AND CEILING SURFACES TO REMAIN, ADD SKIM COAT OF NEW No. Description Date PLASTER TO MATCH ORIGINAL PLASTER TEXTURE. PREP FOR NEW FINISH. G SEE DEMOLITION AND STRUCTURAL DRAWINGS FOR ALL FLOOR REPAIR/INFILL. H SEE ENLARGED PLAN SHEETS FOR ADDITIONAL PARTITION TYPES, NOTES, AND DIMENSIONS. I SEE MEP DRAWINGS FOR BALANCE OF PLAN INFORMATION.

214

7.0

A-101

5.0

Shriners Building

3.0

700-728 S EUCLID AVE. ST. LOUIS, MO 63110

REF.

A-113

700-728 S EUCLID AVE. ST. LOUIS, MO 63110

Shriners Building

CR-118

The Professional Architect's seal affixed to this sheet applies only to the material and items shown on this sheet. All drawings, instruments or other documents not exhibiting this seal shall not be considered prepared by this architect, and this architect expressly disclaims any and all responsibility for such plans, drawings or documents not exhibiting this seal.

This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or part, or for any other purpose or project without the written consent of the architect.

Second Floor Plan

No.

Sheet Title:

Description

Date


Existing Conditions

Site Plan


818 EUCLID RENEWAL

WASHINGTON UNIVERSITY STUDENT HOUSING Washington University in Saint Louis is also converting the Central Institute for the Deaf near Forest Park into graduate student housing. I joined the project during the transition from the design development to the construction document phase. I had responsibilities in editing partition types, drawing exterior details, and conducting site verification.


WITTE BUILDING

COMMERCIAL SPACE RENOVATION The owner of the historic Witte Building located on Laclede’s Landing in Saint Louis hired the Lawrence Group to renovate their interior spaces. The scope included redesigning the first and second floor community spaces, as well as some of the rented tenant spaces throughout the property. I created as-built drawings, schematic design options, and calculated gross rentable space.

Existing Conditions


SSM ST. MARY’S

POST-OCCUPANCY RESEARCH Lawrence Group designed a new 172 patient room hospital to be located in Jefferson City, MO. The building is fully occupied, which gave a unique chance to conduct research to further understand impacts of a decentralized nursing station. These experiments conducted through the evidence-based design model will be able to dictate future design in order to achieve nurse efficiency and optimal patient care. Following the lead of Hui Cai, we measured multiple variables in order to quantify the consequences of a decentralized nursing system in the Med-Surg and ICU departments. A bulk of the efforts were spent performing behavior tracking and behavior mapping by independent observation and nurse shadowing, respectively. We also interviewed those nurses and had them perform an awareness mapping exercise to understand how they collaborated with coworkers. Finally, We measured noise levels throughout the department to see if there was a decibel concentration in the collaboration hubs.

Typical Patient Room


Behavior Tracking Example

Exterior Courtyard


JOHN BURROUGHS HIGH CERAMICS YARD RENOVATION

I took the lead on a small remodel of a ceramic yard at John Burroughs School located in Saint Louis. LG had been designing a new math and science building for the school already, and this small project was a new addition to the overall scope. I visited the site to take photos and measurements in order to create an as-built documentation package. I then submitted multiple renderings of schematic design options for the client to choose from and move forward.


Schematic Rendering

Existing Conditions


CITY FOUNDRY

FEDERAL MOGUL FOUNDRY ADAPTIVE REUSE

City Foundry Saint Louis is an adaptive reuse project that will be located in the new Cortex district of Saint Louis. The $340 million project will include a food hall in the form of rentable stalls, large office spaces, over 45 retail spaces, a parking garage, public spaces, and a walkway connecting the site to the Great Rivers Greenway Trails sytem. I worked on the project sporadically throughout my time at LG. I assisted with schematic site plan drawings, market research, editing red-lines, and squarefoot calculations. When my internship had concluded, abatement of the Federal Mogul site had begun, and the project was in the design development stage.

Community Spaces


Food Hall



Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.