CHARLOTTE MWABA
100502978
AT2.2 TWO STOREY TOWNHOUSE WORKING DRAWINGS DOCUMENTATION VPAU 596 -VU21596 PRODUCE WORKING DRAWINGS
CONTENTS SITE PLAN
A 00 A 01
GROUND FLOOR PLAN FIRST FLOOR PLAN
A 02
NORTH ELEVATION
A 04
WEST ELEVATION
A 04
SECTION A:A
A 05
SECTION B:B
A 06
DETAIL 1
A 07
DETAIL 2
A 08
WINDOW SCHEDULE (GROUND FLOOR)
A 09
DOOR SCHEDULE (GROUND FLOOR)
A 10
ELECTRICAL LAYOUT (GROUND FLOOR)
A 11
A 03
No.181A BRIGHTON STREET
POS LAWN AND GARDEN
EXISTING SINGLE STOREY RESIDENCE
3870
TILED PITCHED ROOF W -HB
W -HB
SITE DEVELOPMENT ANALYSIS TOTAL SITE AREA
PROPOSED FOOTPRINT PERMEABILITY
TPZ 4.8 M
33% (OF SITE AREA) 37% TOTAL PRIVATE OPEN SPACE (OF SITE AREA)
EXISTING BRICK WALL ON BOUNDARY
PAILING FENCE 1.6M HIGH
SECLUDED PRIVATE OPEN SPACE
ENTRY
59 .6 0
1200
4.2M2 PERMEABLE PAVING FFL: 59.60
760
TIMBER FENCE 1.2M HIGH
POS
DISTANCE TO CHURCH ST VIA HOWARD ST 160M
POS
8M2 PERMEABLE PAVING
16M2 PERMEABLE PAVING
FFL: 59.60
FFL:59.80
No.183 BRIGHTON STREET
59.52 AHD
PROPOSED TWO STOREY DWELLING BRICK VENEER
FFL: 59.60
CLOTHESLINE
GARDEN SHED 780mmX2200
ALL METHODS OF CONSTRUCTION SHALL COMPLY WITH AS, NCC & MUNICIPAL COUNCIL. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY SITE WORKS.
.6 0 59
4200 BIOWOOD TIMBER SCREEN 1.6M H
W -HB
W -HB
SILL 60.5 HEAD 62.0
SILL 60.5 HEAD 62.0
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
W -NH
W -HB SILL 60.5 HEAD 62.0
No.185 BRIGHTON STREET
4000
STORM WATER DRAINAGE SHALL BE CONNECTED TO THE LEGAL POINT OF DISCHARGE TO THE SATISFACTION OF THE RELEVANT AUTHORITIES.
CLIENT:
EXISTING SINGLE STOREY RESIDENCE CORRUGATED PITCHED ROOF
PROJECT: TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
PROPOSED GATE ACCESS TO LANEWAY
PAILING FENCE 1.6M HIGH
1000
BITUMEN FOOTPATH
REMOVING EXISTING TREES: ROOT BALL TO BE GROUND OUT AND AREA CLEARED TO GROUND LEVEL BY QUALIFIED ARBORIST. ALL WORK ACCORDING TO AS4970; AS4373
BLUE STONE KERB
59
.4 9
1000
5000
1000
SINGLE GARAGE
FALL
FFL:59.80
EXISTING CROSSOVER TO BE PROTECTED
GENERAL NOTES:
2.6X4.0
FALL
FALL
PERMEABLE GRAVEL DRIVEWAY
PATIO COLOURBOND ROOF SHEETING
GROUND FLOOR ROOF COLOURBOND KLIPLOK ROOF SHEETING
FIRST FLOOR ROOF COLOURBOND KLIPLOK ROOF SHEETING
TIMBER GATE
BRIGHTON STREET
DBH 0.4M
LANEWAY
(OF SITE AREA)
2750 3200 59 .6 0
(57% OF SITE AREA)
PROPOSED BIOWOOD FENCE 1.6M HIGH
NH HB
TELCO PIT GAS METER LPOD WATER METER DIAMETER AT BREAST HEIGHT TREE PROTECTION ZONE RAIN WATER HEAD & DP NON-HABITABLE ROOM WINDOW HABITABLE ROOM WINDOW
1.5M EASEMENT TO LANEWAY
LEGEND
DBH TPZ
EXISTING TREE TO BE REMOVED; SEE NOTES.
EXISTING DECIDUOUS TREE TO BE PROTECTED AS PER AS4970
DRAWING TITLE:
DRAWN BY:
SITE PLAN
CHARLOTTE M 100502978
POS PAVED AREA
CHECKED BY:
DATE
SCALE
CHARLOTTE M
2015/04/01
1:100
REVISON:
PROJECT NO:
SHEET NO:
DRAWING NO:
A
1502#2.2
A-01
01
ORIG. SH. SIZE A3
NOTES: STAIRS:
WITH AS, NCC & 19650
9320
540 200
240 600
1710
1401
1770
2855
795
900
1190
800
4050
5300
900
2870
1310
2170
570
2410
2030
610
1190
3.
STAIRCASE AND STAIRWELL TO BE CONSTRCUTED ACCORDING TO BCA/NCC VOL 2; SEC 3.9.1
4.
WIREFRAME BALUSTRADE AND STAINLESS STEEL HANDRAILS TO BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS AND SPECIFICATIONS
240
SELECTED SECTIONAL GARAGE DOOR AS SPECIFIED
2600 610
BALUSTRADE AND HANDRAIL TO BE MIN 1M FROM NOSING ACCORDING TO BCA/NCC VOL2; SECTION 3.9.2.3.
FIRST FLOOR OVER SHOWN DASHED
4550
1810
2.
EXTERNAL WALL TO BE BRICK VENEER (40MM CAVITY) INTERNAL WALL TO BE 90MM TIMBER STUDS
INSTALLATION AND FIXING IS TO BE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS
190 1310
STRINGER AND TREADS TO BE BLACKBUTT POLISHED TIMBER.
240 1240
240
240
900
2600
RISER: 175mm GOING: 250mm NOSING: 20mm
1.
ALL METHODS OF CONSTRUCTION SHALL COMPLY WITH AS, NCC & MUNICIPAL COUNCIL.
1670
CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY SITE WORKS.
240
AJ
11
D 10
90 D 09
3900X2600 CH 2700
FFL:59.80 WM/DR
POL. CONCRETE FCL62.50
L'DRY TILE
POL. CONCRETE FCL 62.50
FFL:59.80
FCL62.50
10
D 03
FIRST FLOOR OVER
AJ
D 04
D 05
DP
DP
SHED 2200X780
CLOTHES LINE 2530X800
240
9
1355
8
630 240 2980
1400
100 1830 100
12
6
COVERED PATIO
100
5
DINING
3750
FFL:59.60 6000X4000 FCL62.50
LIVING
910
B 06
D 06
1830
13
240
4
710
3260
WC TILE
SINGLE GARAGE
90
14
3
1340
15
2
350
240 810
16
UP
760
B 06
6940
710
350
D 07
680
W 06
FFL:59.80
1
350
1210
STORE
AJ
1210
1060
OUTDOOR AREA
90
POL. CONCRETE FCL 62.50
240
POL. CONCRETE FCL62.50
AJ
683
KITCHEN
1350
PLAY AREA
PERMEABLE PAVING
7
240
P
W 02
D 02
240 910 90 1290
3720
3740
W 04
FR VOID
2500
FFL:59.60
17
110
W 03
BUILT SHELVING
PERMEABLE PAVING
820
2870
AJ
COURTYARD
W 01
3250
2500
AJ
D 01
DP
W 05
D 08
1350
1210 730
1130
6830
110
680
1155
90
FFL:59.80
AJ
DP
1351
STUDY FCL62.50 POL.CONCRETE
745
ENTRY DP
STORE
1290
DP
1310
1560
1290
REFER TO SPECIFICATION FOR FIXTURES, FITTINGS AND FINISH INFORMATION
A 05
AJ STAINLESS STEEL HANDRAIL FIXED TO WALL WIREFRAME BALUSTRADE NEWEL POSTS 80x100mm
05 A 2990
600
1800
1800
1690
960 110
6000
800
2057 90 1790
350
4790
800
4800
4952
4548
191 1396
240
624
90
5180
4320
90
4140
240 2530
2260
4800
1150 100
19730
CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
GROUND FLOOR PLAN
DRAWN BY:
CHARLOTTE M 100502978
1150 100 2600
100
CHECKED BY:
DATE
SCALE
CHARLOTTE M
2015/04/01
1:100
REVISON:
PROJECT NO:
SHEET NO:
A
1502#2.2
A-02
ORIG. SH. SIZE A3
DRAWING NO: 02
NOTES: STAIRS:
STRINGER AND TREADS TO BE BLACKBUTT POLISHED TIMBER.
2.
BALUSTRADE AND HANDRAIL TO BE MIN 1M FROM NOSING ACCORDING TO BCA/NCC VOL2; SECTION 3.9.2.3.
3.
STAIRCASE AND STAIRWELL TO BE CONSTRCUTED ACCORDING TO BCA/NCC VOL 2; SEC 3.9.1
4.
460
140
4630
2340
820
1345
EXTERNAL WALL CLADDING TO BE LAID VERTICAL BIOWOOD TIMBER SHEET BOARDS
6800 90
140
1610
2420
370
1020 1600
WIREFRAME BALUSTRADE AND STAINLESS STEEL HANDRAILS TO BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS AND SPECIFICATIONS
GROUND FLOOR ROOF PLAN SHOWN UNDER
12180 140
RISER: 175mm GOING: 250mm NOSING: 20mm
1.
1880 1180
90
800
590
970
INTERNAL WALL TO BE 90MM TIMBER STUDS
140
INSTALLATION AND FIXING IS TO BE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS
2425 4658
ALL METHODS OF CONSTRUCTION SHALL COMPLY WITH AS, NCC & MUNICIPAL COUNCIL. CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY SITE WORKS. REFER TO SPECIFICATION FOR FIXTURES, FITTINGS AND FINISH INFORMATION
A 05
LEGEND LEGEND
90 DIA. DP AS SPECIFIED
250
250
140
RAIN WATER HEAD LOCATED IN BOX GUTTER AS SPECIFIED
5
12
BATH
MIN FCL 64.50 TILE
6
9
730
140
10
W 07
W 06
1290 900
4010
140
140790
8
7
1310
2410
BIR
11
W 08
100
140 MIN FCL 64.50 TILE
1260
D 01
B 06
MIN FCL 64.50 FFL:62.80 CARPET
1035
MIN FCL 64.50 CARPET
13
BEDROOM 2
BIR
14
3 4
GROUND FLOOR ROOF COLOURBOND KLIPLOK ROOF SHEETING
W 05
140 755
2110
WIR
15
2
LINEN CUP'B
ENS.
16
UP
740
D 03
FALL
3940
1
90
D 04
MAX.FCL 65.20 FFL:62.80 CARPET
D 02
B 06
867
HALLWAY
1110
W 04
FFL:62.80 MIN FCL 64.50 CARPET
160
970
744
MASTER BEDROOM
900
190
90 810
W 03
17
650
5325
2820
970
W 02 W 01
STAINLESS STEEL HANDRAIL FIXED TO WALL WIREFRAME BALUSTRADE NEWEL POSTS 80x100mm
3890 140
2200
900 820
1600
05 A
1530 1020
1170 985
90 2000
1220
900 850 45
2610
510
800 370
1790
3300 590
1915 90
1670 90
510
140 2425
93
12200
CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
DRAWN BY:
FIRST FLOOR PLAN
CHARLOTTE M 100502978
CHECKED BY:
DATE
SCALE
CHARLOTTE M
2015/04/01
1:100
REVISON:
PROJECT NO:
SHEET NO:
DRAWING NO:
A
1502#2.2
A-03
03
ORIG. SH. SIZE A3
1810 W MIGLAS AWNING WINDOW AS SPECIFIED
NOTES:
SHEETING WITH PARAPET WALLS TO SIDES BIOWOOD WALL CLADDING SPOTTED GUM FINISH
COLOURBOND PARAPET FLASHING CAPPING AS SPECIFIED
CLIMBER TRELLIS MESH (CTM) -AS SPECIFIED FIXED TO WALL
EXTERNAL FIRST FLOOR WALLS CLADDING TO BE LAID VERTICAL; BIOWOOD TIMBER BOARDS
GARAGE SECTIONAL DOOR AS SPECIFIED CUSTOM CLAD WITH BIOWOOD TIMBER PANEL
EXTERNAL RECYCLED BRICK WALL
EXTERNAL GROUND FLOOR WALL TO BE FACE BRICK
BIOWOOD WALL CLADDING GARAGE WALL SPOTTED GUM FINISH
INSTALLATION AND FIXING IS TO BE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS ALL METHODS OF CONSTRUCTION SHALL COMPLY WITH AS, NCC & MUNICIPAL COUNCIL.
FCL 62.50
BOUNDARY
BOUNDARY
CTM HEIGHT
A
W 01
ALL DIMENSIONS (INCLUDING NOMINAL MAX BUILDING HEIGHT ABOVE NGL) ARE NOMINAL CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY SITE WORKS.
FG
REFER TO WINDOWS AND DOOR SCHEDULES FOR WINDOW AND DOOR INFORMATION
350
6150
FFL 62.80
2400
2850
MIN FCL 64.50
2400
300
MAX. FCL 65.20
2700
D 10
2820
3250
REFER TO GENERAL SPECIFICATION MATERIALS AND FINISHES INFORMATION
FFL 59.80 NGL
WEST ELEVATION -2 MIGLAS AWNING WINDOW AS SPECIFIED 2170W 610W MIGLAS AWNING WINDOW AS SPECIFIED
SHEETING WITH PARAPET WALLS TO SIDES
COLOURBOND PARAPET FLASHING CAPPING AS SPECIFIED
COLOURBOND PARAPET FLASHING
BIOWOOD WALL CLADDING SPOTTED GUM FINISH
TIMBER FRAMED PATIO COULOURBOND CORRUGATED ROOF
LYSAGHT TAPERED RWH AS SPECIFIED
TIMBER POST; 75mm PRYDA POST ANCHOR
2900 2700
W 05
W 02
FG
W 04
A
W 03
A
FG
FG
FG
D 08
300
950
A
DP
200
FFL 59.80 NGL
A
240 3050 2700 3085
FCL 62.50
A
AJ
2465
FFL 62.80
W 04
350
6150 NOMINAL B.HEIGHT
MIN. FCL 64.50
BOUNDARY
BOUNDARY
MAX. FCL 65.20
AJ
AJ
DP
SL
FG
D 01
DP
AJ
NORTH ELEVATION -1 CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
DRAWN BY:
CHECKED BY:
REVISON:
DATE
SCALE
NORTH & WEST ELEVATIONS
CHARLOTTE M
CHARLOTTE M
A
2015/04/01
1:100
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A04
04
100502978
ORIG. SH. SIZE A3
NOTES: EXTERNAL WALL TO BE CLAY BRICK GROUND FLOOR TO BE MECHANICALLY POLISHED CONCRETE
CEILING GLASSWOOL INSULATION AS SPECIFIED ROOF FOIL BLANKET INSULATION AS SPECIFIED
SELECTED FLOORING TO BE LAID OVER 22MM PARTICLE BOARD SHEET FIXED TO POSI STRUTS ON FIRST FLOOR
120X45 RAFTER F17 SEASONED HARDWOOD @ 600 SPACING
ALL EXTERNALLY CLAD 90MM TIMBER STUDS TO BE FULLY SARKED MITEK POSI STRUTS TO BE INSTALLED AS PER MITEK INSTRUCTOINS AND MANUFACTURER'S SPECIFICATIONS
COLOURBOND FLASHING CAPING AS SPECIFIED
REFER TO WINDOWS AND DOOR SCHEDULES FOR WINDOW AND DOOR INFORMATION
BOUNDARY
D-02 A-06
300
MAX. FCL 65.20
BOUNDARY
REFER TO GENERAL SPECIFICATION FOR SPECIFIED MATERIALS AND PRODUCT INFORMATION
F5 38X38 CEILING BATTEN
SPECIFIED WALL BATT INSULATION
2400
3000
MIN. FCL 64.50
D 04
BED 2
BATH
LYSAGHT COLOURBOND DP AND SPREADER AS SPECIFIED BIOWOOD VERTICAL WALL CLADDING SHEETS; FIXED BY ADHESIVE AS SPECIFIED
FFL 62.80
350
LYSAGHT BOX GUTTER LYSAGHT RWH
2700
LYSAGHT DP
3050
6240
NOM. BUILDING HEIGHT
FCL 62.50
RENDERED BRICK WORK
WC
KIT
W 02
L'DRY
D 06
FG
D 09
CAV SL
ST WEEP HOLE @ 1200MM CENTRES
FFL 59.80 NGL
VAPOUR BARRIER TO EXTEND ABOVE SLAB REINFORCED CONCRETE SLAB AND FOOTINGS ACCORDING TO ENG. SPECIFICATIONS
SECTION A:A (TYPICAL CROSS SECTION) CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
DRAWN BY:
CHECKED BY:
REVISON:
DATE
SCALE
SECTION A:A
CHARLOTTE M
CHARLOTTE M
A
2015/04/01
1:50
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A05
05
100502978
ORIG. SH. SIZE A3
NOTES: STAIRS: RISER: 175mm GOING: 250mm NOSING: 20mm 1. STRINGER AND TREADS TO BE BLACKBUTT POLISHED TIMBER. 2. BALUSTRADE AND HANDRAIL TO BE MIN 1M FROM NOSING ACCORDING TO BCA/NCC VOL2; SECTION 3.9.2.3. 3. STAIRCASE AND STAIRWELL TO BE CONSTRCUTED ACCORDING TO BCA/NCC VOL 2; SEC 3.9.1 4. WIREFRAME BALUSTRADE AND STAINLESS STEEL HANDRAILS TO BE INSTALLED AS PER MANUFACTURERS INSTRUCTIONS AND SPECIFICATIONS EXTERNAL WALL TO BE CLAY BRICK GROUND FLOOR TO BE MECHANICALLY POLISHED CONCRETE SELECTED FLOORING TO BE LAID OVER 22MM PARTICLE BOARD SHEET FIXED TO POSI STRUTS ON FIRST FLOOR ALL EXTERNALLY CLAD 90MM TIMBER STUDS TO BE FULLY SARKED FRAMING UNDER ALL ROOF SHEETING AND BATTENS TO BE FULLY SARKED MITEK POSI STRUTS TO BE INSTALLED AS PER MITEK INSTRUCTOINS AND MANUFACTURER'S SPECIFICATIONS REFER TO WINDOWS AND DOOR SCHEDULES FOR WINDOW AND DOOR INFORMATION REFER TO GENERAL SPECIFICATION FOR SPECIFIED MATERIALS INFORMATION ROOF FOIL BLANKET INSULATION AS SPECIFIED 120X45 RAFTERS @ 600MM SPACING F17 SEASONED HARDWOOD
BOUNDARY
BOUNDARY
COLOURBOND FLASHING CAPING AS SPECIFIED
COLOURBOND KLIP LOK ROOF SHEETING
MAX. FCL 65.20 MIN FCL 64.50
2700
3200
ENS. W 02
BIOWOOD VERTICAL WALL CLADDING SHEETS FIXED BY ADHESIVE AS SPECIFIED
COLOURBOND KLIP LOK ROOF
A LINEN CUP'B
WIR
BATH BIR
FCL 62.50
BEDROOM 2
ROOF FOIL BLANKET INSULATION AS SPECIFIED
M
D-02 A-06 D 02
350
6450
NOMINAL. BUILDING HEIGHT
FFL 62.80
SPECIFIED GOLD WALL BATT INSULATION
MITEK POSI STRUTS @ 450MM SPACING
COLOURBOND FLASHING CAPING AS SPECIFIED
H
17 16 15
STAIR VOID
REF. V
13
PLAY AREA GARAGE SECTIONAL GARAGE DOOR AS SPECEFIED
190X45 SPOTTED GUM EXPOSED FASCIA FOR RAFTERS
14
WC
2100
2700
3250
DOUBLE LEAF GARAGE WALL WITH STEEL LINTEL OVER OPENING
D 07
KIT
WITH BUILT IN SHELVES
A A
STAKING PATIO DOOR WITH SILL
A
FG
CAV.SL
KITCHEN BREAKFAST BAR W 03
FG
100MM SPOTTED GUM POST
FG
FFL 59.80 NGL
PRYDA POST ANCHOR TO SLAB VAPOUR BARRIER TO EXTEND ABOVE SLAB EDGE REINFORCED CONCRETE SLAB AND FOOTINGS ACCORDING TO ENG. SPECIFICATIONS
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
CLIENT:
PROJECT:
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
SECTION B:B
DRAWN BY: CHARLOTTE MWABA 100502978
CHECKED BY: CHARLOTTE M
REVISION: A
DATE
SCALE
2015/04/01
1:50
PROJECT NO:
SHEET NO:
1502#2.2
A06
ORIG. SH. SIZE A2
DRAWING NO: 06
350
90
30
190
LOK ROOF SHEETING BRADFORD ATNTICON ROOF BLANKET INSULATION AS SPECIFIED
COLOURBOND FLASHING CAPPING
F5 ROOF BATTEN 35X70 @ 450 SPACING THERMOSEAL REFLECTIVE ROOF SARKING AS SPECIFIED
BOX GUTTER OVERFLOW OUTLET
90X45 F7 TIMBER SUPPORT PLATE F17 RAFTER 120X45 SEASONED HARDWOOD @ 600 SPACING
LYSAGHT RAIN WATER HEAD AS SPECIFIED LYSAGHT DP 90mm DIA SPECIFIED GOLD WALL BATT INSULATION
BIOWOOD VERTICAL WALL CLADDING PANEL FIXED BY ADHESIVE MIGLAS WINDOW HEAD 10MM CLEARANCE FLASHED WITH PACKER
CEILING PLASTERBOARD 10mm CEILING GLASSWOOL INSULATION AS SPECIFIED BETWEEN CEILING BATTENS
F5 CEILING BATTEN 38X38 @ 450 SPACING MIGLAS AWING WINDOW SYSTEM DOUBLE GLAZED TIMBER INTERNAL REVEAL ALUMINIUM EXTERNAL REVEAL
STAIRCASE VOID
OUTDOOR
DETAIL 1 -FIRST FLOOR BOX GUTTER SCALE 1:10 CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
DETAIL 1
DRAWN BY: CHARLOTTE MWABA 100502978
CHECKED BY:
CHARLOTTE M
REVISON:
DATE
SCALE
A
2015/04/01
1:10
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A07
07
ORIG. SH. SIZE A3
90mm STUD WALL WITH 10mm PLASTERBOARD FIXED WALL INSULATION BATTS AS SPECIFIED BIOWOOD VERTICAL WALL CLADDING PANEL FIXED BY ADHESIVE
FIRST FLOOR
OUTDOOR
VERTICAL APRON FLASHING AS SPECIFIED SPECIFIED CARPET OVERLAY PARTICLE SHEET FLOORING 22mm
F5 ROOF BATTEN 35X70 THERMOSEAL REFLECTIVE ROOF SARKING AS SPECIFIED
MITEK POSI STRUT TRUSS @ 450 CENTRES
F17 RAFTER 240X45 SEASONED HARDWOOD
F5 CEILING BATTEN 38X38 CEILING PLASTERBOARD 10mm
GROUND FLOOR GLASSWOOL INSULATION AS SPECIFIED BETWEEN CEILING BATTENS
190X45 F7 TIMBER SUPPORT PLATE AND PACKER 310 UB AS PER ENGINEERING SPEC. PRYDA FRAMING BRACKET FIXED WITH PRYDA TIMBER CONNECTOR NAILS FIXED TO RAFTER AND SUPPORT PLATE
DETAIL 2 -HIDDEN BEAM UNDER FIRST FLOOR LOADBEARING WALL CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
DETAIL 2
DRAWN BY: CHARLOTTE MWABA 100502978
CHECKED BY:
CHARLOTTE M
REVISON:
DATE
SCALE
A
2015/04/01
1:10
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A08
08
ORIG. SH. SIZE A3
GENERAL NOTES
LEGEND
SCHEDULE TO BE READ IN CONJUCTION WITH SPECIFICATION
A -AWNING
ALL DIMENSIONS INDICATED ARE NOMINAL. CLARIFY DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION
FG -FIXED GLASS PANE 'W01' -WINDOW NUMBER REFERENCE TO PLANS 'D01' -DOOR NUMBER REFERENCE TO PLANS
WINDOWS
SL -SLIDING WINDOWS SHALL BE INSTALLED ACCORDING TO MIGLAS INSTALLATION GUIDELINES, RELEVANT AUSTRALIAN STANDARDS AND BCA/NCC GLAZING SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS
H-HINGED ST-STACKING CAV SL -CAVITY SLIDING
ALL SPECIFIED WINDOW SYSTEMS REQUIRE REGULAR CLEANING AND MAINTENANCE TO ENSURE PERFORMANCE AND DURABILITY
FG
CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
W 02
PROJECT: NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
930
A
A
W 05 950
FG
950
FG
300
W 01
300
300
FFL 59.80
FG
772
1150 A
W 04 FG
1210
1000
A
610
600
1150
610
600
340 2058
A
1810
340
2058
2700
340
FFL 62.50
1210
2058
1210
W 06
W 03
DRAWING TITLE:
GROUND FLOOR WINDOW SCHEDULE
DRAWN BY:
CHECKED BY:
REVISON:
DATE
SCALE
CHARLOTTE M
CHARLOTTE M
A
2015/04/01
1:100
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A09
09
100502978
ORIG. SH. SIZE A3
LEGEND
GENERAL NOTES
A -AWNING SCHEDULE TO BE READ IN CONJUCTION WITH SPECIFICATION
FG -FIXED GLASS PANE 'W01' -WINDOW NUMBER REFERENCE TO PLANS
ALL DIMENSIONS INDICATED ARE NOMINAL. CLARIFY DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION
'D01' -DOOR NUMBER REFERENCE TO PLANS SL -SLIDING
PROVIDE WEATHER STRIPING AT ALL EXTERIOR DOORS
H-HINGED
INSTALLATION AND FIXING IS TO BE IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS
ST-STACKING CAV SL -CAVITY SLIDING
REFER TO SPECIFICATION FOR HARDWARE INFORMATION
1210
800
700
820
720
720
620
2170 1065
3225 1065
1040
3200
1080
1060
FFL 59.80
H
D 02
FG
H
D 03
H
CAV SL
D 06
CAV SL
D 08
SL
D 09
FG
ST
ST
600
600 D 04 D 01
600
640
FG
600
2400
2400
2400
2400
2400
1720
2500
2700
350
800
300
820 FFL 62.50
900
FG
D 10
NGL
CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
GROUND FLOOR DOOR SCHEDULE
DRAWN BY:
CHECKED BY:
REVISON:
DATE
SCALE
CHARLOTTE M
CHARLOTTE M
A
2015/04/01
1:100
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A10
10
100502978
ORIG. SH. SIZE A3
LEGEND
NOTES:
EXTERIOR LIGHT FITTING
ELECTRICAL LAYOUT GENERALLY REPRESENTS COMPONENTS AND CIRCUIT PATHS. READ IN CONJUNCTION WITH ELECTRICAL ENGINEERING DRAWINGS.
EXHAUST FAN SMOKE DETECTOR
SMOKE ALARM DEVICES SHALL BE INSTALLED TO COMPLY WITH NCC VOLUME 2. AND AS 3786-1993
DIMENSIONS REFER TO HALLWAY LIGHT FITTINGS
TV CONNECTION PLATE
READ IN CONJUNCTION WITH SPECIFICATION AND ALL OTHER RELEVANT APPROVED PLANS
TELEPHONE OUTLET
ALL DIMENSIONS INDICATED ARE NOMINAL. CLARIFY DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION
RECESSED CEILING LIGHT FIXTURE DOUBLE GPO @ 1200 ABOVE FFL DOUBLE GPO @ 350 ABOVE FFL
1370
2410
2580
915
1980
2640
2640
2430
2140
W
725
AJ
CH 2700
AJ
1
AJ
COURTYARD FFL:59.60
W 01
W 03
BUILT SHELVING
1
1-WAY SWITCH
2
2-WAY SWITCH
3
3-WAY SWITCH
AJ
STUDY D 01
DOUBLE WATERPROOF GPO
METER BOX
W 05
W 04
W 02
AJ
D 02
PLAY AREA
KITCHEN
CH 2700
CH 2700
OUTDOOR AREA
1 AJ
W 06
FFL:59.80
3 D 08
W
3 D 07 1
2 2
2
D 06 3
SINGLE GARAGE
WC
4
CH 3000
2
5
FFL:59.60
WM/DR D 10
1
8
7
9
LIVING
DINING
CH 2700
CH 2700
COVERED PATIO
D 09
CH 2700
L'DRY
6
FFL:59.80
10
W
W AJ
D 03
D 04
832
510 225
1
D 05
2
1550 90 2000 1750
1120
2620
LIGHT FITTED TO CENTRE OF GARAGE CEILING
CLIENT:
MELBOURNE OFFICE 22 SMITH ST, SOUTH YARRA MELBOURNE, VICTORIA WWW.FFBD.COM.AU
S.FINLEY 10 MARKSVILLE COURT, BENTLEIGH, MELBOURNE VICTORIA 3206
PROJECT: TWOSTOREY TOWNHOUSE WORKING DRAWINGS NEW RESIDENCE: SITE: 183 BRIGHTON STREET, RICHMOND, 3121 DRAWINGS NOT TO BE USED FOR CONSTRUCTION PURPOSES UNTIL BUILDING PERMIT ISSUED AND APPROVED. DO NOT SCALE DRAWINGS.
DRAWING TITLE:
GROUND FLOOR ELECTRICAL LAYOUT
DRAWN BY:
CHECKED BY:
REVISON:
DATE
SCALE
CHARLOTTE M
CHARLOTTE M
A
2015/04/01
1:100
PROJECT NO:
SHEET NO:
DRAWING NO:
1502#2.2
A 11
A 11
100502978
ORIG. SH. SIZE A3