ucts od
Man uf
ing Green tur Pr c a
Si n c
e 1 992
ucts od
Man uf
ing Green tur Pr ac
Si n c
e 1 992
INDEPENDENCE™
INDEPENDENCE™
INDEPENDENCE™
INDEPENDENCE™
1
2
3
2 1
3
INDEPENDENCE™
TECHNOLOGY OVERVIEW
12
www.aircleansystems.com
Phone: +1 (919) 255-3220
Toll Free: (800) 849-0472
Fax: +1 (919) 528-0015
13
*Additional filters are available for specific applications upon request.
14
www.aircleansystems.com
Phone: +1 (919) 255-3220
Toll Free: (800) 849-0472
Fax: +1 (919) 528-0015
15
B
A
E
Brushless/ Sparkless Blower
Bonded Carbon and/or HEPA Filters
D Pre-Filters Vapor-Proof Fluorescent Light
B AirZone™ Internal Baffling
A
B
E
Brushless/ Sparkless Blower
Bonded Carbon and/or HEPA Filters
D Pre-Filters Vapor-Proof Fluorescent Light
B AirZone™ Internal Baffling
A
B
PATRIOT™ DUCTLESS FUME HOOD DIMENSIONS - FOLDING SASH Product #
External Dimensions
Internal Dimensions
Width
Depth
Height
Width
Depth
Height
ACPT3000
36”
30”
54”
35”
26”
35”
ACPT3036
36”
36”
54”
35”
32”
35”
ACPT4000
48”
30”
54”
47”
26”
35”
ACPT4036
48”
36”
54”
47”
32”
35”
ACPT5000
60”
30”
54”
59”
26”
35”
ACPT5036
60”
36”
54”
59”
32”
35”
ACPT6000
72”
30”
54”
71”
26”
35”
ACPT6036
72”
36”
54”
71”
32”
35”
E Brushless/ Sparkless Blower Silconazyne™ Filter Optional HEPA or Bonded Carbon Filter
D
HighEfficiency Fluorescent Light
B
A
B
A Pre-Filter Brushless/ Sparkless Blower HEPA Filter Fluorescent Light
B
A
B
A Brushless/Sparkless Blower
Pre-Filter
HEPA Filter
Fluorescent Light
B
Brushless/Sparkless Blower AirSafe™ Controller HEPA Filter Pre-Filter
A
B
HEPASafe™ technology allows the operator to safely and easily change both the pre-filter and the primary HEPA filter while the enclosure is operational
Real-time readout of face velocity with precise airflow control and monitoring
“Flow smooth” foil provides even air distribution throughout enclosure, preventing turbulence
Electrical and utility cord access port
E
D
A
B
Brushless/Sparkless Blower Optional Bonded Carbon Filter
E
D Permanent HEPA Filter Primary HEPA Filter
B A Pre-Filter
1) Air enters at “A” in an even horizontal laminar fashion. 2) Contaminated air enters “B” where particulate is removed via electrostatic pre-filtration and HEPA filtration. 3) Particulate-free air moves upward to “C” where it enters the HEPASafe™ filtration area. 4) Particulate-free air then passes into “D”, the bonded carbon filtration bed, where dangerous chemical fumes and vapors are removed. 5) Clean air is then exhausted at “E” for return to the laboratory.
Brushless/Sparkless Blower
E Optional Bonded Carbon Filter
D Permanent HEPA Filter Primary HEPA Filter
B A
Pre-Filter
A Pre-Filter Brushless/ Sparkless Blower
HEPA Filter
UV Light Fluorescent Light
B
Pipette Shelf Slip Hatch
Brushless/Sparkless
E
Blowers
HEPA Filters
D
Fluorescent Light
UV Light
A
B
E
D
A
B
Brushless/Sparkless Protected Blower AirSafe™ Controller HEPA Filter Fluorescent Light
A
B
D
Bonded Carbon Filter HEPA Filter FlameRetardant Pre-Filter
A
B
Brushless/ Sparkless Blower
22"
10"
7"
A Pre-Filter Blower HEPA Filter Fluorescent Light
B
UV Light
Brushless/ Sparkless Blower Bonded Carbon Filter or HEPA Filter
B Pre-Filter
A
Optional Fluorescent Light (Standard on 48� workstations)
Brushless/ Sparkless Blower
Bonded Carbon Filter
PreFilter
A
B
Exhaust Plenum
Brushless/Sparkless Blowers
AirSafe™ Automatic Safety Controller
Bonded Carbon Filters Pre-Filter
Fume Hood Connection
Locking Casters
E
D
C A
C
B
A
D
B
A C