House and wall detail - Wood frame- AutoCAD

Page 1

BARDEAUX D'ASPHALTE 20 ANS 12

12

8

8

12

12

8" (TYPE)

8

NOTE IMPORTANTE 8 LA CONSTRUCTION DOIT REMPLIR LES EXIGENCES DE LA PARTIE II DU CODE DE CONSTRUCTION, CHAPÎTRE BÂTIMENT. PRÉVOIR LES CHANGEMNTS NÉCESSAIRE AUX SPÉCIFICATIONS D'ISOLATION. LE RÉGLEMENT SUR "L'EFICACITÉ ÉNERGÉTIQUE " DEVRA ÊTRE COMPLÉTÉE PAR UN SPECIALISTE EN MÉCANIQUE DU BÂTIMENT.

SOLIN (TYPE) LINTEAU D'ACIER

PLAFOND R-DE-C

PLAFOND R-DE-C

POURCENTAGE D'OUVERTURES

2'-2"

=

3'-0"

0" - 62" : "L" 3-1/2" X 3-1/2" X 1/4"

1'-6"

63" - 88" : "L" 4" X 4" X 1/4"

PLANCHER R-DE-C PIERRE (TYPE)

89" -120" : "L" 5" X 3-1/2" X 1/4"

PLANCHER R-DE-C

3'-0" CRÉPI DE CIMENT (TYPE)

8'-0"

NIVEAU SOL FINI

8'-0"

1'-4"

BLOCS ARCHITECTUREAUX (TYPE)

NIVEAU SOL FINI

A ÉLÉVATION AVANT A3 Échelle : 3/16"=1'-0"

121" + : "L" 6" X 4" X 5-16"

DESSUS FONDATION

3'-0"

DESSUS FONDATION

LINTEAU D'ACIER AU-DESSUS DES OUVERTURES

ALLÈGE DE PIERRE (TYPE)

=

6'-4"

=

8'-2"

HAUT MUR SOUFFLÉ (VOIR DÉTAIL)

MUR HOR-SOL : 1413 PI.CA. 131,27 M.C OUVERTURES : 242PI.CA. 22,48 M.C. % OUVERTURES/MURS : 17313 %

REVÊTEMENT HORIZONTAL (TYPE)

8'-2"

=

=

2'-0" (TYPE)

DESSUS SEMELLE

DESSUS SEMELLE

DESSOUS SEMELLE

DESSOUS SEMELLE

NOTES GÉNÉRALES:

12

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS. - LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉS SELON LA NATURE DU SOL. - PRÉVOIRE UNE FINITION IMPERMÉABLE AUTOUR DE TOUS LES BAINS ET DOUCHES. - DOUBLER LES SOLIVES SOUS LES CLOISONS PARALLÈLES ET CAGES D'ESCALIERS. - LES LINTEAUX AUTOUR DES OUVERTURES SERONT DE 2-(2X12) SAUF INDICATION CONTRAIRE SUR LE PLAN. - LES HOTTES ET VENTILATEURS MÉCANIQUES DEVRONT ÉVACUER VERS L'EXTÉRIEUR. - PLANIFIER L'INSTALLATION D'UN ÉCHANGEUR D'AIR OBLIGATOIRE DU C.N.B DEPUIS 2012.

12

8

8 BARDEAUX D'ASPHALTE 20 ANS

PLAFOND R-DE-C

PLAFOND R-DE-C

L'ENTREPRENEUR OU MAITRE D'OEUVRE DOIT COORDONNER TOUS LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT D'ENTREPRENDRE LES TRAVAUX.

8'-2"

8'-2"

IMPORTANT

Projet :

Projet Final PLANCHER R-DE-C

PLANCHER R-DE-C

DESSUS FONDATION

DESSUS FONDATION

Titre :

Maison NIVEAU SOL FINI

8'-0"

8'-0"

NIVEAU SOL FINI

ARMATURE 1/2" Ø (TYPE)

Dessiner par :

Vérifié par :

CINDY OKINO Date :

A ÉLÉVATION ARRIÈRE A3 Échelle : 3/16"=1'-0"

NATHALIE MARTEL Révision :

22/06/2018

22/06/2018

Échelle :

DESSUS SEMELLE DESSOUS SEMELLE

DESSUS SEMELLE DESSOUS SEMELLE

3/16"=1'-0"

A3


SOLIN (TYPE)

12 6

12

IMPORTANT: 8" (TYPE)

BARDEAUX D'ASPHALTE 20 ANS

6

L'entrepreneur ou maitre d'oeuvre avant d'entreprendre les travaux devra mesurer sur place et coordonner tout les niveaux, toutes les pentes et toutes les dimensions sur le chantier avant l'éxécution des travaux.

PLAFOND R-DE-C

BLOCS ARCHITECTURAUX (TYPE)

8'-2"

2'-0" (TYPE)

Toutes les structures devront êtres vérifiés et approuvées par un ingénieur en structure. Prévoir un maître électricien pour l'installation électrique. Prévoir un plombier certifié pour l'installation de la tuyauterie.

PLANCHER R-DE-C DESSUS FONDATION

8'-0"

NIVEAU SOL FINI CRÉPI DE CIMENT (TYPE)

A ÉLÉVATION DROITE A4 Échelle : 3/16"=1'-0"

DESSUS SEMELLE DESSOUS SEMELLE

NOTES GÉNÉRALES: - LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS. - LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉS SELON LA NATURE DU SOL. - PRÉVOIRE UNE FINITION IMPERMÉABLE AUTOUR DE TOUS LES BAINS ET DOUCHES. - DOUBLER LES SOLIVES SOUS LES CLOISONS PARALLÈLES ET CAGES D'ESCALIERS. - LES LINTEAUX AUTOUR DES OUVERTURES SERONT DE 2-(2X12) SAUF INDICATION CONTRAIRE SUR LE PLAN. - LES HOTTES ET VENTILATEURS MÉCANIQUES DEVRONT ÉVACUER VERS L'EXTÉRIEUR. - PLANIFIER L'INSTALLATION D'UN ÉCHANGEUR D'AIR OBLIGATOIRE DU C.N.B DEPUIS 2012.

SOLIN (TYPE)

12 6

12 BARDEAUX D'ASPHALTE 20 ANS

6

PLAFOND R-DE-C

8'-2"

L'ENTREPRENEUR OU MAITRE D'OEUVRE DOIT COORDONNER TOUS LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT D'ENTREPRENDRE LES TRAVAUX.

Projet :

76"

= = =

IMPORTANT

Projet Final

42" MIN.

REVÊTEMENT HORIZONTAL (TYPE)

PLANCHER R-DE-C Titre :

DESSUS FONDATION

Maison 8'-0"

NIVEAU SOL FINI CRÉPI DE CIMENT (TYPE)

Dessiner par :

Vérifié par :

CINDY OKINO Date :

A ÉLÉVATION GAUCHE A4 Échelle : 3/16"=1'-0"

NATHALIE MARTEL Révision :

22/06/2018

22/06/2018

Échelle :

DESSUS SEMELLE DESSOUS SEMELLE

3/16"=1'-0"

A4


SELON LE C.N.B. POUR LES ESCALIERS

30'-0" 23'-6" 8'-0"

ART.8.8.2.2 ÉCHAPÉE Mesurer à partir du bord extérieur du nez de marche 1950 mm (77 po) min.

6'-6"

10'-0"

12'-0"

PILIER DE BÉTON 10' Ø SUR ASSISE DE BÉTON 25" X 25" X 8" TYP.

ART.9.8.8.4 HAUTEUR GARDE-CORPS Intérieur des logements et si max.71 po au-dessus du sol 900 mm (36 po de haut) 1070 mm (41 po de haut) pour plus de 71 po au-dessus du sol.

8"

60 X 24 POUTRE 3-(2 X 10)

PRÉVOIR CLOUAGE 2 X 10 DE BOIS TRAITÉ + ÉTRIERS À SOLIVES ANCRÉÀ LA RIVE DU PLANCHER AVEC 2 BOULONS 12" Ø @ 32" C/C

ART 9.8.7.1 MAINS COURANTES EXIGÉES Une main courante doit être installée sur au moins 1 côté d'un escalier. Sur les 2 côtés pour un escalier tournant. 8'-0"

SOLIVES 2 X 10 @ 16" C/C

8"

ART.9.8.8.5 OUVERTURES ENTRE LES BAROTINS 100 mm max(4 po) entre les barotins.

PILIER DE BÉTON 10" Ø SUR ASSISE DE BÉTON 25" X 25" X 8"(TYPE)

AU DESSUS PONTAGE 1 1 4" X 6" ESPACÉ 18"

ART 9.8.7.4 HAUTEUR DES MAINS COURANTES Doivent avoir une hauteur d'au moins 800 mm et d'au plus 965 mm (30 à 34 po de haut). DRAIN AGRIC. 4" Ø + FILTRE PÉRIMÉTRIQUE

LINT. -(2 X 12) ENCASTRÉ

SORTIE DE SÉCHEUSE

NOTES GÉNÉRALES:

15'-4"

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS. - LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉS SELON LA NATURE DU SOL. - PRÉVOIRE UNE FINITION IMPERMÉABLE AUTOUR DE TOUS LES BAINS ET DOUCHES. - DOUBLER LES SOLIVES SOUS LES CLOISONS PARALLÈLES ET CAGES D'ESCALIERS. - LES LINTEAUX AUTOUR DES OUVERTURES SERONT DE 2-(2X12) SAUF INDICATION CONTRAIRE SUR LE PLAN. - LES HOTTES ET VENTILATEURS MÉCANIQUES DEVRONT ÉVACUER VERS L'EXTÉRIEUR. - PLANIFIER L'INSTALLATION D'UN ÉCHANGEUR D'AIR OBLIGATOIRE DU C.N.B DEPUIS 2012.

5'-2"

30" X 10"

2'-6"

PRÉVOIR ARMATURE 1/2" Ø @ 8" C/C DANS LES DEUX SENS + 5 À 8 % AIR ENTRAINÉ POUR BALCON DE BÉTON 8"

10"

3'-6"

2'-8"

7'-0"

13'-2"

60 X 24

14'-8"

13'-2"

POUTRELLES DE PLANCHER 11 7 8" (VOIR FAB.)

IMPORTANT L'ENTREPRENEUR OU MAITRE D'OEUVRE DOIT COORDONNER TOUS LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT D'ENTREPRENDRE LES TRAVAUX.

1'-8"

60 X 24

1'-4"

3280

2-(2X10) MUR PORTEUR 2 X 4 @ 12' C/C + ENTREMISES À MI=HAUTEUR (TYPE)

POTEAU 3-(2 X 4) + PLAQUE D'ACIER

7'-0"

30'-0"

3'-8" POUTRE "PARALLAM" 7' X 11 7 8" ENCASTRÉE + ÉTRIERS

5'-2"

30'-0"

16'-0"

DRAIN DE PLANCHER 4" Ø

IMPORTANT: PRÉVOIR UN DÉTECTEUR DE FUMÉE À L'ÉTAGE, DANS TOUS LES CHAMBRES (OU À MOINS DE 16'-0" DE LA PORTE DE DE CELLE-CI DANS UN CORRIDOR). L'INSATALLATION SERA CONFORME AU CNB DU QUÉBEC CHAPITRE 1. IMPORTANT:

ENTRÉE EN VIGUEUR AU CODE DU CNB 2010 MODIFIÉ UN AVERTISSEUR DE FUMÉE DOIT ÊTRE INSTALLÉ DANS CHAQUE PIÈCE OÙ L'ON DORT (1X CHAMBRE) AINSI QUE UN PAR ÉTAGE DANS LES CORRIDORS INCLUANT LE SOUS-SOL. UN DÉTECTEUR DE MONOXYDE DE CARBONE (CO) EST REQUIS S'IL Y A UN FOYER AU GAZ OU AU BOIS OU UN GARAGE ANNEXÉ À LA MAISON.UN DÉTECTEUR COMBINÉ EST AUTORISÉ IL DOIT ÊTRE SITUÉ DANS LE CORRIDOR À MOINS DE 5 M DES CHAMBRES À COUCHER.(VOIR ARTICLE 9.32.3.9 DU CNB)

23'-0"

5'-4"

2-(2X4)

3280

10'-0"

24" X 8" (TYPE)

SEMMELES

13'-2"

POUTRELLES DE PLANCHER 11 7 8" (VOIR FAB.)

POUTRELLES DE PLANCHER 11 7 8" (VOIR FAB.)

16'-10"

SELON LE C.N.B. POUR NORMES INCENDIES

PLAFOND EN PENTE (VOIR COUPE P. 4/4)

24" x 12" (TYPE)

8" (TYPE)

POUTRELLES DE PLANCHER 11 7 8" (VOIR FAB.)

60 X 24

7'-0"

POUTRELLE RENFORCÉE (TYPE)

8" 9'-0"

8'-8" 10'-0"

8" 11'-0"

PRÉVOIR ARMATURE 2 X 15 M HAUT ET BAS DES FONDATIONS

30'-0"

Projet :

Projet Final FONDATION RÉGULIÈRE FONDATION SUIVANT L'ANGLE DES MARCHES

A PLAN DE FONDATION A1 Échelle : 1/8"=1'-0"

A VUES ISOMÉTRIQUES A1 Échelle : SANS ÉCHELLE

Titre :

SEMMELES & MURS

Maison Dessiner par :

NOTE MURS DE FONDATION: SELON LE TYPE DE PIERRE EXTÉTIURE CHOISI, PRÉVOIR, AU BESOIN, DES MURS DE FONDATIONS DE 21" EN REMPLACEMENT DES MURS DE 10".

NOTE ÉLÉMENT "PARALAM": TOUTES DIMENSIONS DES ÉLÉMENTS "PARALAM" DEVRONT ÊTRE VÉRIFIÉES PAR L'INGÉNIEUR DU FABRICANT

Vérifié par :

CINDY OKINO Date :

NATHALIE MARTEL Révision :

22/06/2018

22/06/2018

Échelle :

INDIQUÉE

A1


4'-3"

8'-9"

10'-6"

28 X 66

6'-6"

72 X 82

84 X 66

NOTE FÊNETRES: C.N.B.9.7.1.5: HAUTEUR DES APPUIS DE FÊNETRES OUVRANTES AU-DESSUS DES PLANCHET AU SU SOL:

8'-0"

10'-0"

LORSQUE L'APPUIS DE LA FÊNETRE EST SITUÉ À MOINS DE 900mm (36 PO.) DU PLANCHER FINI OU QUE LE NIVEAU DU PLANCHER FINI SOUS LA FÊNETRE EST À PLUS DE 60mm (23,6 PO.) AU-DESSUS D'UN AUTRE PLANCHER OU LE SOL DE L'AUTRE COTÉ DE LA FÊNTRE, LES FÊNETRES DOIVENT:

12'-0"

- ÊTRE PROTEGÉES PAR UN GARDE-CORPS INSTALÉ CONFORTÉMENT À LA SECTION 9.8.; OU - L'OUVERTURE DOIT ÊTRE LIMITÉE VERTICALEMENT OU HORIZONTALEMENT À AU PLUS 100mm (4 PO.).

BALCON DE BOIS TRAITÉ 10'-0" X 8'-0"

NOTE STRUCTURE DE LA TOITURE: SE RÉFÉRER AU PLAN DE TOITURE FOURNI PAR LE FABRICANT DES FERMES DE TOIT POUR L'EMPLACEMENT EXACT DE APPUIS ET DES POUTRES ET/OU DES FERMES MAÎTRESSES.

LINT. 3-(2 X 10)

14'-4"

8'-6" X 10'-0"

2'-6"

REF. DOUCHE 36" X 48"

20'-6" X 12'-6"

PRÉVOIR ACCÈS À L'ENTRETOIT 22" X 28" + COUPE-FROID

MURET 42" DE HAUT (TYPE)

13'-2"

FERMES DE TOIT @ 24" C/C TYPE "A" TRONQUÉES

8'-2"

8'-2"

SORTIE DE HOTTE

FERMES DE TOIT @ 24" C/C TYPE "A"

LINT. 3-(2 X 12)

POTEAU 3-(2 X 6) (TYPE)

A A5

2'-4"

BAIN 32" X 60"

MAIN COURANTE 36" DE HAUT. AVEC ESPACEMENT DES BARREAUX DE 4 " LIBRE MAX . (C.N.B. 9.8.8)

3080 3080

24" (TYPE)

33'-6"

3080

30'-0"

7'-0" MIRROIR

3'-8"

3'-8"

8'-2"

28 X 54

30'-0" 33'-6"

A A5

8'-6"

3080

8'-4"

12'-8" 4'-2"

SORTIE DE VENTILATEUR

3080

6'-4" FERMES DE TOIT @ 24" C/C TYPE "A"

6'-0"

2'-4"

6'-8"

3'-10"

2

13'-2"

1 3680

15'-8"

12'-0" X 12'-0"

NOTES GÉNÉRALES: - LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS. - LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉS SELON LA NATURE DU SOL. - PRÉVOIRE UNE FINITION IMPERMÉABLE AUTOUR DE TOUS LES BAINS ET DOUCHES. - DOUBLER LES SOLIVES SOUS LES CLOISONS PARALLÈLES ET CAGES D'ESCALIERS. - LES LINTEAUX AUTOUR DES OUVERTURES SERONT DE 2-(2X12) SAUF INDICATION CONTRAIRE SUR LE PLAN. - LES HOTTES ET VENTILATEURS MÉCANIQUES DEVRONT ÉVACUER VERS L'EXTÉRIEUR. - PLANIFIER L'INSTALLATION D'UN ÉCHANGEUR D'AIR OBLIGATOIRE DU C.N.B DEPUIS 2012.

10'-0" X 10'-0" 3'-10"

3480

11'-2"

4'-4"

2'-0"

4'-4"

LINT. 3-(2 X 10)

LINT. 3-(2 X 12)

POTEAU 6X6 (TYPE)

28

8"

1'-4"

3'-6"

56 POUTRE 3-(2 X 6) (TYPE)

2'-2"

FERMES DE TOIT @ 24" C/C TYPE "B"

38

8"

2'-2"

28

1'-4"

3'-6"

LINT. 3-(2 X 10)

8"

PANNEAU "OSB" 7/16"

BALCON DE BÉTON 10'-0" X 3'-6"

1'-4" 9'-0" (VOIR ÉLÉV.) 66 X 48 4'-3"

7'-4"

11'-0"

10'-6" 6'-8"

IMPORTANT

POLYSTIRÈNE EXTRUDÉ 1" TYPE 4 (R-5)

(VOIR ÉLÉV.) 84 X 66

64 X 82 9'-9"

10'-8"

1'-4"

10'-0"

5'-6"

L'ENTREPRENEUR OU MAITRE D'OEUVRE DOIT COORDONNER TOUS LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT D'ENTREPRENDRE LES TRAVAUX.

SOUFFLAGE EN 2 X 3 @ 16" C/C

12'-8"

Projet :

30'-0"

FOURRURES 1X 3 @ 16" C/C

Projet Final

ALLÈGE DE PIERRE

A PLAN REZ-DE-CHAUSSÉE A2 Échelle : 1/8"=1'-0"

A PLAN DU TOIT A2 Échelle : 1/8"=1'-0"

PIERRES

Titre :

Maison Dessiner par :

Vérifié par :

CINDY OKINO Date :

A DÉTAIL DU MUR SOUFFLÉ : PIERRE/REV. HORIZ. A2 Échelle : 1/2"=1'-0"

NATHALIE MARTEL Révision :

22/06/2018

22/06/2018

Échelle :

INDIQUÉE

A2


IMPORTANT:

FERMES DE TOIT TYPE "A" TRONQUÉES (VOIR FABRICANT)

L'entrepreneur ou maitre d'oeuvre avant d'entreprendre les travaux devra mesurer sur place et coordonner tout les niveaux, toutes les pentes et toutes les dimensions sur le chantier avant l'éxécution des travaux.

FERMES DE TOIT TYPE "A" (VOIR FABRICANT)

12

12

8

Toutes les structures devront êtres vérifiés et approuvées par un ingénieur en structure.

8

Prévoir un maître électricien pour l'installation électrique. Prévoir un plombier certifié pour l'installation de la tuyauterie.

PLAFOND R-DE-C

8'-2"

PLAFOND R-DE-C

SOFFITE VENTILÉ EN ALUMINUIM

MURET 42" DE HAUT

8'-2"

8'-2"

SOFFITE VENTILÉ EN ALUMINUIM

POUTRELLE RENFORCÉE (TYPE)

NOTES GÉNÉRALES:

PLANCHER R-DE-C

- LA CONSTRUCTION DEVRA ÊTRE EXÉCUTÉE SELON LES NORMES DU C.N.B DU CANADA, L'ÉDITION EN COURS. - LES EMPATTEMENTS DEVRONT ÊTRE MODIFIÉS SELON LA NATURE DU SOL. - PRÉVOIRE UNE FINITION IMPERMÉABLE AUTOUR DE TOUS LES BAINS ET DOUCHES. - DOUBLER LES SOLIVES SOUS LES CLOISONS PARALLÈLES ET CAGES D'ESCALIERS. - LES LINTEAUX AUTOUR DES OUVERTURES SERONT DE 2-(2X12) SAUF INDICATION CONTRAIRE SUR LE PLAN. - LES HOTTES ET VENTILATEURS MÉCANIQUES DEVRONT ÉVACUER VERS L'EXTÉRIEUR. - PLANIFIER L'INSTALLATION D'UN ÉCHANGEUR D'AIR OBLIGATOIRE DU C.N.B DEPUIS 2012.

PLANCHER R-DE-C 2-(2X4)

DESSUS FONDATION

DESSUS FONDATION

1'-4"

8'-8"

5'-4" PENTE 2%

NIVEAU SOL FINI

8'-0"

PENTE 2%

8'-0"

NIVEAU SOL FINI

10'-0" 6'-5" MIN. (ÉCHAPPÉE)

14'-8"

IMPORTANT L'ENTREPRENEUR OU MAITRE D'OEUVRE DOIT COORDONNER TOUS LES NIVEAUX, TOUTES LES PENTES ET TOUTES LES DIMENSIONS SUR LE CHANTIER AVANT D'ENTREPRENDRE LES TRAVAUX.

8" Projet :

DESSUS SEMELLE

DESSUS SEMELLE

Projet Final

DESSOUS SEMELLE

DESSOUS SEMELLE 2'

Titre :

Maison A COUPE AA A5 Échelle : 1/4"=1'-0"

Dessiner par :

Vérifié par :

CINDY OKINO Date :

NATHALIE MARTEL Révision :

22/06/2018

22/06/2018

Échelle :

1/4"=1'-0"

A5


BARDEAUX D'ASPHALTE

A DÉTAIL TOIT A1 Échelle : 1"=1'-0"

BANDE DE DÉPART SOLIN

GOUTIÈRE

FASCIA

TOITURE :

MOULURE EN "J" -

SOFFITE

12 6

DÉFLECTEUR

SOLIN D'ALUMINIUM

-

BARDEAUX D'ASPHALTE BANDE DE DÉPART 3'-0" SOUS-COUCHE (DECKGARD) CONTREPLAQUÉ 1/2" AVEC COLISSEAUX (AGRAFES EN "H") FERMES DE TOIT @ 24" C/C LAINE ISOLANT R-60 PARE-VAPEUR SCELLÉ FOURRURES 1" X 3" @ 16" C/C GYPSE 1/2"

12 6

DÉFLECTEUR

GOUTIÈRE

EL. 108'-1 3/4''

LISSE 2 X 8

DESSUS SABLIERE FASCIA D'ALUMINIUM

MUR EXTÉRIEUR VINYLE

SOFFITE PERFORÉ -

MOULURE EN "J"

SOLIVES DE RIVES DOUBLES AU DESSUS DES OUVERTURES

EL. 100'-0"

REVÊTEMENTEXTERIEUR (CLIN VINYLE) FOURRURES 1 x 3 @ 16" C/C PARE-AIR TYPE TYVEK REVÊTEMENT INTERMÉDIAIRE CONTREPLAQUÉ 1/2" MONTANT 2 X 6 @ 16" C/C LAINE MINÉRALE R-20 PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm FOURRURES 1 X 3 @ 16" C/C GYPSE VISSÉE 1/2"

PLINTHE -

LISSE D'ASSISE 2X4

EL. 98'-9 1/4

SOLIN

DESSUS FONDATION

BOULONS D'ANCRAGE 1/2"Ø X 6" @ 4'-0" C/C

-

SABLIÈRE DOUBLE (2-2" X 6")

BRIQUE 4" AVEC ATTACHE MÉTALIQUE (FEUILLARD) FOURRURES 1 x 3 @ 16" C/C ESPACE D'AIR 1" PARE-AIR TYPE TYVEK REVÊTEMENT INTERMÉDIAIRE CONTREPLAQUÉ 1/2" MONTANT 2 X 6 @ 16" C/C LAINE MINÉRALE R-20 PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm FOURRURES 1 X 3 @ 16" C/C GYPSE VISSÉE 1/2"

PLANCHER REZ-DE-CHAUSSÉE :

ISOLANT D'URÉTHANE GICLÉ

PLANCHER RDCH.

MUR EXTÉRIEUR BRIQUE

PLINTHE FEUILLARD

FINI DE PLANCHER CONTREPLAQUÉ 3/4" EMBOUVETÉ POUTRELLES DE PLANCHER AUTOPORTANTES 14" H. (voir fabricant) FOURRURES 1" X 3" @ 16" C/C GYPSE 1/2"

CHANTEPLEURS @ 24" C/C SOLIN

ÉTAFOAM

ANCRAGES 1/2" Ø X 6 LG @ 4'-0" C/C

CRÉPI PENTE 2%

PENTE 2%

MUR DE FONDATION VINYLE : -

MEMBRANE BITUMINEUSE GOUDRONNÉE MUR DE FONDATION 8" MONTANTS 2X4@16"C/C - ESPACE D'AIR 1/4" URÉTHANE GICLÉ 2 12 ÉP. TYPE PARE-VAPEUR FOURRURES 1 X 3 @ 16" C/C GYPSE VISSÉE 1/2"

MUR DE FONDATION BRIQUE : -

MEMBRANE BITUMINEUSE GOUDRONNÉE MUR DE FONDATION 10" MONTANTS 2X4@16"C/C - ESPACE D'AIR 1" URÉTHANE GICLÉ 2 12 ÉP. TYPE PARE-VAPEUR FOURRURES 1 X 3 @ 16" C/C GYPSE VISSÉE 1/2"

ARMATURE CONTINU 1/2"Ø AU NIVEAU DU SOL FINI, EN DESSOUS DES FENÊTRES ET DANS LE BAS DES MURS DE FONDATION

EL. 90'-9 1/4'' 90'-4 1/4'' EL.

DESSUS DALLE

JOINT D'ÉTANCHEITÉ

DESSUS EMPATTEMENTS

PIÈRRE CONCASSÉE 3/4" NET. MIN

8"

PLINTHE

DALLE : -

DRAIN FRANÇAIS 4"Ø AVEC MEMBRANE GÉOTEXTILE

2'

Projet :

10" ARMATURE 1/2"Ø @ 24" C/C

FINITION DALLE DE BÉTON 4" ÉP. (AVEC TREILIS MÉTALIQUE 6X6) ISOLANT RIGIDE 1" ÉP. (TYPE 4) R-5 PARE-VAPEUR POLYÉTHYLÈNE 0.006 mm PIÈRRE CONCASSÉE 8" / 10" ÉP. SOL NON-REMANIÉ

Titre :

COUPES DE MURS Dessiner par :

Vérifié par :

2'-6" CINDY OKINO Date :

A COUPE MUR VINYLE A1 Échelle : 3/8"=1'-0"

A COUPE MUR BRIQUE A1 Échelle : 3/8"=1'-0"

NATHALIE MARTEL Révision :

21/06/2018 Échelle :

INDIQUÉE

A1