Oglivy HR HOLT RENFREW OGILVY
Architect Rockefeller Center 1700 Broadway Suite 400 New York NY 10019 Phone: 212 492 1400 Fax: 212 492 1472
Heintges Facade Consultant 440 Park Avenue South, 15th Floor New York, NY 10016 Phone: 212.652.2966
10.31.2016 ISSUE FOR 100% DESIGN DEVELOPMENT
NCK Structural Engineer 1200 Avenue McGill College Bureau 1200 Montreal, QC, H3B 4G7 Phone: 514.878.3021 Fax: 514.878.2402
Kugler Ning Lighting Design Lighting Design 247 West 47th Street #1502 New York, NY 10018 Phone: 212.382.2100
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
ABBREVIATIONS
SHEET INDEX
SHEET NOTES
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
SHEET INDEX
A ACCESS ACOUS AFF AL ALT ANNUNC ANOD APPL ARCH AUTO AVG &
HVAC ACCESSORY ACOUSTIC(AL) ABOVE FINISHED FLOOR ALUMINUM ALTERNATE ANNUNCIATOR ANODIZED APPLIANCE ARCHITECT(URAL) AUTOMATIC AVERAGE AND BUILDING BOLLARD BOARD BLOCKING BROADLOOM BUILT UP
C CAB CPT CEM CER CLG COATG COILG CONC CONSTR CONT CONTR COV CMU
DOUBLE DEPARTMENT DESIGN(ED) DETAIL DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DISPENSER DIVISION DOWN DOLLAR (US CURRENCY) DOOR DISCONNECT DRAWER ELASTOMERIC ELECTRICAL EMBEDD(ED)(ING) ENGINEER(ED) ENTRANCE EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXPOSED(D) EXTERIOR
F FAB FD FE FE&C FHC FIN FLDG FPLC FR FRMG FXD FXTR FLR FURN FWC
FABRICATION FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER AND CABINET FIRE HOSE AND CABINET FINISH FOLDING FIREPLACE FIRE RAT(ING)(ED) FRAMING FIXED FIXTURE FLOOR(ING) FURNITURE FABRIC WALL COVERING
G GA GFRC GFRG GFRP GL GR GYP
INFORMATION INSTRUMENT(ATION) INSULATION INTERLOCK(ING) INTERIOR INFILTRATION
J JAN
K
KIT
JANITOR KITCHEN
LAV LB £ LT LVLG LVT MAX MFD MFR MECH MET MEMB MEZZ MIN MISC MLWK MOIST MOT MTD
LAVATORY POUND BRITHISH POUND (CURRENCY) LIGHT LEVELING LOUVER MAXIMUM MANUFACTURED MANUFACTURER MECHANICAL METAL MEMBRANE MEZZANINE MINIMUM MISCELLANEOUS MILLWORK MOISTURE MOTOR(IZED) MOUNTED
SIM SST STD STL STRFR STRUCT SURF SUSP SYS
SIMILAR STAINLESS STEEL STANDARD STEEL STOREFRONT STRUCTURAL SURFACE SUSPENDED SYSTEM(S)
Sheet Number A-0000 A-0001 A-0002 A-2000 A-2001 A-4000 A-4001 A-4100 A-6000 A-6001 A-6002 A-6100 A-6200 A-6201 A-6202 A-6300 A-6400 A-6401 A-6402 A-6500 A-6600 A-6700
T THK TLT TRAF TRANS TRTD T&G TYP
THICK TOILET TRAFFIC TRANSPARENT TREATED TOUNGUE AND GROOVE TYPICAL
U UNDRLAY UTIL UNO
V
VEH VERT VIF
UNDERLAYMENT UTILITY UNLESS NOTED OTHERWISE VECHICLE VERTICAL VERIFY IN FIELD
W W/ WC WD WDW W/O WT WTRPRF
Sheet Name COVER PAGE DRAWING INDEX DOOR SCHEDULE, DOOR TYPES, WALL TYPES & FINISH SCHEDULES ENLARGED DLM FACADE - ELEVATIONS ENLARGED DLM FACADE SCRIM ENLARGED DLM FACADE - PLANS ENLARGED DLM FACADE - PLANS WALL SECTIONS - DLM Wall Type 'A', 'A1' WALL TYPE 'A', 'A1' PLAN DETAILS WALL TYPE A, A1 SECTION DETAILS Wall Type "B" Wall Type "C" WALL TYPE 'C' PLAN DETAILS WALL TYPE 'C' INTERIOR ELEVATION & SECTION VESTIBULE WALL TYPE 'C1' Wall Type "D" WALL TYPE 'D' PLAN DETAILS WALL TYPE 'D' VITRINE DETAILS CANOPY PLANS AND SECTIONS ENTRY AND DISPLAY WINDOW AREA DETAILS OGILVY CANOPY
10.31.2016 ISSUE FOR 100%DD
08.05.2016 ISSUE FOR BID ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ● ■
WITH WATER CLOSET WOOD WINDOW WITHOUT WEIGHT WATERPROOFING
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
N
E ELAST ELEC EMBED ENGR ENTR EQ EQUIP EXIST EXP JT EXPS EXT
INFO INSTRUM INSUL INTLK INT INFILTR
M CABINET CARPET CEMENT(ITIOUS) CERAMIC CEILING COATING COILING CONCRETE CONSTRUCTION CONTINUOUS(ATION) CONTRACT(OR) COVER CONCRETE MASONRY UNIT
D DBL DEPT DES DET DF DIA DIFF DIM DISP DIV DN $ DR DSCON DWG
I
L
B BLDG BOLLD BD BLKG BRDLM BU
HEATING, VENTILATIING, AND AIR CONDITIONING
Holt Renfrew | Ogilvy
GAUGE GLASS FIBER REINFORCED CONCRETE GLASS FIBER REINFORCED GYPSUM GLAS FIBER REINFORCED PLASTER GLASS GRAD(E)(ING) GYPSUM
NIC NO NTS
NOT IN CONTRCT NUMBER NOT TO SCALE
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
O ORNA OVFL OVHD OPNG OPR
ORNAMENTAL OVERVLOW OVERHEAD OPENING(S) OPERABLE
INTERIOR LIGHTING CONSULTANT
P PTN PEDR PBD PNL POLYST PORT PREFIN PREFAB PLAM PLAS PLSTC PLYWD PRTECN
PARTITION PEDESTRIAN PARITICLE BOARD PANEL POLYSTRENE PORTABLE PREFINISHED PREFABRICATED PLASTIC LAMINATE PLASTER PLASTIC PLYWOOD PROTECTION
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
R RDR RECES RECPT REF REFL REFR REQD RESIS REINF RESIL RFG RM RO
S
SCR SECUR SF SG SHORG
READER RECESSED RECEPTACLE REFER(ENCE) REFLECTED REFRIGERATOR REQUIRED RESIST(ANT)(IVE) REINFORCED(D)(ING)(MENT) RESILIENT ROOFING ROOM ROUGH OPENING SCRIBE SECURITY SQUARE FEET SINGLE SHORING
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
CONSTRUCTION NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
ALL DIMENSIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR" OR "HOLD." ALLOW FOR THICKNESS OF FINISHES. COORDINATE AND PROVIDE BLOCKING WITHIN PARTITIONS FOR ALL MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. UNDERCUT OF DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4" UNLESS OTHERWISE NOTED. ALL INTERIOR GLAZING TO BE SAFETY GLAZING IN ACCORDANCE WITH APPLICABLE CODES. MARK THE LOCATION OF ALL PARTITIONS ON THE SLAB FOR REVIEW BY THE ARCHITECT PRIOR TO INSTALLATION. REVIEW SHALL BE FOR DESIGN INTENT. CONTRACTOR TO VERY ALL CONDITIONS IN ORDER TO ENSURE PROPER FIT. ALL PARTITIONS SHALL BE PERPENDICULAR OR PARALLEL TO BUILDING CORE WALLS, UNLESS OTHERWISE NOTED. HINGE FACE OF ALL DOOR OPENINGS SHALL BE LOCATED 6" FROM ADJACENT PERPENDICULAR WALL, UNLESS OTHERWISE NOTED. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. (REVIEW WITH ARCHITECT IN THE FIELD) REPAIR AND/OR RESTORE ALL EXISTING FIREPROOFING DAMAGED DUE TO DEMOLITION AND NEW WORK. FIREPROOFING SHALL BE AS REQUIRED TO MAINTAIN EXISTING FIRE PROTECTION RATING. PATCH AND REPAIR ALL EXISTING AND/OR NEW PENETRATIONS THROUGH EXISTING FIRE RATED SLABS AND PARTITIONS, AS REQUIRED, TO MAINTAIN EXISTING FIRE PROTECTION RATING. PATCH AND REPAIR ALL EXISTING WALLS, COLUMNS AND SURFACES SCHEDULED TO REMAIN AS REQUIRED TO LEAVE THEM SMOOTH AND EVEN TO RECEIVE NEW SCHEDULED FINISHES. REFER TO FINISH PLAN FOR ADDITIONAL INFORMATION.
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
H HD HDWD HDWE HM HORIZ
HEAD HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL
FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
DEMOLITION NOTES 1. 2. 3.
COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. PROVIDE AND MAINTAIN BARRICADES, LIGHTING AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT WORKERS AND OCCUPANTS OF THE BUILDING. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT THE SPREAD O DUST, FUMES, SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. UPON COMPLETION OF WORK, REMOVE PARTITIONS AND REPAIR SURFACES DAMAGED TO MATCH ADJACENT SURFACES. 4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE EFFECTED AREAS AT NO ADDITIONAL COST TO THE OWNER. 5. REMOVE FROM THE SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH AND OTHER MATERIALS RESULTING FORM DEMOLITION OPERATIONS. 6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT AND FIXTURES AS REQUIRED FOR NEW WORK. 7. REMOVE ABANDONED HVAC EQUIPMENT INCLUDING DUCTWORK. 8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, INCLUDING THE CONTENTS OF FLOOR CELL RACEWAY SYSTEMS, UNLESS OTHERWISE NOTED. 9. REMOVE EXISTING FLOOR FINISHES AND PREPARE SUBFLOOR AS REQUIRED TO RECEIVE NEW FLOOR FINISHES, UNLESS OTHERWISE NOTED. 10. REMOVE EXISTING CEILINGS, DUCTWORK, LIGHTING AND OTHER CEILING MOUNTED DEVICES, UNLESS OTHERWISE NOTED. 11. REMOVE EXISTING PLUMBING FIXTURES AS INDICATED INCLUDING PLUMBING LINES BACK TO BUILDING RISERS. 12. FOR ALL ITEMS SCHEDULED FOR REMOVAL AND REINSTALLATION, CONTRACTOR SHALL VERIFY AND DOCUMENT, IN WRITING, THE CONDITION AND FUNCTIONALITY OF THE ITEM(S) PRIOR TO REMOVAL. ANY DAMAGE TO ITEM(S) NOT DOCUMENTED SHALL BE REPAIRED BY CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
Date 1 2
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
Seal/Signature
GENERAL NOTES 1. 2. 3.
4.
5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
ALL WORK SHALL COMPLY WITH ALL LOCAL BUILDING CODES, LAWS, ORDINANCES, RULES AND REGULATIONS OF THE PUBLIC AUTHORITIES GOVERNING THE WORK. OBTAIN AND PAY FOR ALL PERMITS, INSPECTIONS AND FINAL SIGN-OFFS REQUIRED BY THE PUBLIC AUTHORITIES GOVERNING THE WORK. THE DRAWINGS AND PROJECT MANUAL ARE COMPLEMENTARY AND THEIR INTENT IS TO INCLUDE ALL ITEMS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT REQUIRED FOR THE CONSTRUCTION OF THE PROJECT. THE ORGANIZATION OF THE DRAWINGS AND PROJECT MANUAL SHALL NOT CONTROL THE CONTRACTOR IN DIVIDING WORK AMONG THE SUBCONTRACTORS OR IN ESTABLISHING THE EXTENT OF WORK PERFORMED BY ANY TRADE. REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. THE CONTRACTOR SHALL REPORT ANY CONFLICTS AND/OR OMISSIONS TO THE ARCHITECT PRIOR TO PERFORMING ANY WORK IN QUESTION. OTHERWISE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS TO COMPLETE THE WORK STATED IN ON THE CONTRACT DOCUMENTS BASED UPON THE OPTIMAL ESTABLISHED QUALITY STANDARD. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS AND/OR CHANGES TO THE ARCHITECT, IN WRITING, FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES AND USE OF ELEVATORS AS TO MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. OWNER WILL PROVIDE WORK NOTED AS "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION. MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES AND ALARMS FOR DURATION OF WORK IN ACCORDANCE WITH APPLICABLE CODES AND ORDINANCES. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE FOR DURATION OF WORK. ALL DAMAGE DUE TO IMPROPER PROTECTION SHALL BE REPAIRED AT NO ADDITIONAL COST TO THE OWNER. MAINTAIN WORK AREAS SECURE AND LOCKABLE FOR THE DURATION OF WORK AND COORDINATE WITH OWNER/LANDLORD TO ENSURE SECURITY. PROVIDE A DULY AUTHORIZED FULL-TIME REPRESENTATIVE ON THE JOB SITE AT ALL TIMES FOR SUPERVISION OF CONSTRUCTION AS OUTLINED IN THE PROJECT MANUAL. SUBMIT SAMPLES, DATA SHEETS AND SHOP DRAWINGS AS OUTLINED IN THE PROJECT MANUAL. MAINTAIN THE CONSTRUCTION PREMISES IN A NEAT AND ORDERLY CONDITION AS OUTLINED IN THE PROJECT MANUAL. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, THE CONTRACTOR SHALL SUBMIT A WRITTEN REQUEST FOR CLARIFICATION OR INFORMATION TO THE ARCHITECT. TELEPHONE INQUIRIES WILL NOT BE PERMITTED.
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
DRAWING INDEX
Scale
A-0001 © 2016 Gensler
SEE SCHED
DOOR SCHEDULE NUMBER 001 002 100 101
LOCATION
DOOR TYPE B B A A
WIDTH (mm) 0.89 0.89 1.90 1.86
FRAME
DIMENSIONS HEIGHT (mm) THICKNESS (mm) 2.30 0.04 QDLM EGRESS 2.30 0.04 QDLM EGRESS 3.59 MAIN ENTRY 3.59 VESTIBULE
MATERIAL MTL MTL GLASS GLASS
FINISH MT-06 MT-06 GLGL-
MATERIAL MTL MTL NONE NONE
FINISH MT-06 MT-06
ASSEMBLY RATING DETAILS JAMB 3/A-4002 3/A-4002
HEAD
2/A-4002 2/A-4002
SILL
2/A-4002 2/A-4002
FIRE RATING 45 45 NA NA
TEMP RISE
SMOKE LABEL
HARDWARE GROUP 2 2 1 1
REMARKS FINISH TO MATCH ADJ W-D WALL TYPE M-6 FINISH FINISH TO MATCH ADJ W-D WALL TYPE M-6 FINISH CUSTOM FRAMELESS GLASS DOOR CUSTOM FRAMELESS GLASS DOOR
DLM FACADE OWNER
REFER TO SCHE'D
HARDWARE GROUP No. 02 PROVIDE EACH DOOR WITH THE FOLLOWING:
QTY
DESCRIPTION CATALOG NUMBER
FINISH MFR
QTY
DESCRIPTION CATALOG NUMBER
FINISH MFR
1
CUSTOM BY CW MANUF W/ FULL HT DEADBOLDHOUSING DORMA CLOSER BT S80 ADA OPERATOR AND PIVOTS
SS
TBD
SS SS
DR TBD
2 1 1 1
HINGES PANIC HARDWARE CLOSER KICK PLATE
SS SS 26D 630
2 2
3
TE340 (UP TO 176LB) DORMA 9000 8916-SPA-T 90-8X34-.050-B4E COUNTERSUNK SCREWS 1608
SILENCERS
Wall Type
Description: Material & System Type
Glass Type
Curtainwall System consists of insulating glass units [GL-01] and coated aluminum spandrel panels [MT-02] four side structurally silicone glazed onto extruded aluminum glazing adapter frames fastened to standard-profile extruded aluminum framing. System incorporates continuous air seal closure/flashing to perimeter substrate.
MASTER ARCHITECT
TECTUS DORMA DORMA DON-JO ARCHITECT OF RECORD
DON-JO
Glass Makeup (all glass low-iron, heat treatment as required by design and/ or code)
Glass Coating
Center of Glass U-Value (Winter)
SHGC
W / m2-°K
A and A-1
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
Performance Criteria: Wind pressure/ suctions of +/- 0.81 kPa servicability; +/- 1.07kPa ultimate at field zones
System Finish
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
HARDWARE SETS HARDWARE GROUP No. 01 PROVIDE EACH DOOR WITH THE FOLLOWING:
SHEET NOTES
SEE SCHED
ASSEMBLY
SEE SCHED
Max module width mm
Max system vertical Max glass size span between supports mm
DOOR TYPE: A
HM DOOR, FINISH TO MATCH W-D
DOUBLE GLASS DOOR W/ TOP & BOTTOM SS RAILS
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
TYPICAL DOOR TYPES
Mullion size
mm
DOOR TYPE: B
01
SCALE: 1 : 20
INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
mm
METAL STUD Aluminum Mullion (MT-03) and GL-01 Aluminum Panel (MT-02): Exterior: A-1 Interior: A-2
GL-01: Typical Vision Glass IGU 35 mm [1-3/8"] insulating glass unit » 10 mm [3/8"] low iron HS outer lite » 16 mm [5/8"] argon airspace » 10 mm [3/8"] low iron HS laminated inner lite (5 mm [3/16"] + 5 mm [3/16"])
Double silver low-e coating on #2 surface Acceptable coatings: » Viracon VE-2M ^
1.42** ^
0.41** ^
1750
5220
1550 x 4806
150 x 70
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
System includes coated aluminum backpan, integral mineral fiber insulation, and galvanized steel vapor barrier sheet at spandrel zones, and integral mineral fiber insulation with galvanized steel vapor barrier sheet at aluminum panels. System includes stainless steel brackets where indicated to accept connection to W-B wind load brackets.
DOOR BOLT INTERIOR LIGHTING CONSULTANT
System is deadloaded at Level 5 and anchored for wind at Levels 2, 3, and 4. Dead load anchor for W-B penetrates system at Level 5.
TOP RAIL
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
** Published values ^ Coating, U-Value, and SHGC have not been reviewed / confirmed by Mechanical...
B
Outrigger Screen Wall System consists of custom 5mm [3/16"] aluminum panels [MT-01], laser cut and formed per architect's drawings, attached to vertically-oriented anodized aluminum support channels secured to custom steel truss assembly [MT-07]. System includes solid aluminum return panels [MT-05] at glazed areas of W-A, and at edge conditions, per architect's drawings.
GLASS DOOR Aluminum Scrim Panel (MT-01): n/a A-1
n/a
n/a
n/a
n/a
1750
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
7400 (at Max panel size: n/a cantilever) 1775 x 1400mm
Aluminum Return Panel (MT-05): A-1
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
Steel framing system includes vertical and horizontal truss Steel Framing (MT-07): members with horizontal wind-load struts tying back at each floor to M-1 integral brackets on W-A system. System is to be engineered and specified by Structural Engineer.
PUSH-PULL SET STRUCTURAL ENGINEER
System is deadloaded at Level 5 and anchored for wind at Levels ...
C and C-1
Storefront, Vestibule, and Vitrines System consists of insulating glass units [GL-02] or four-side structurally silicone glazed onto extruded alumninum glazing adapter frames fastened to steel mullions clad with stainless steel sheet [MT-04]. System incorporates continuous air seal closure/flashing to perimeter substrate.
EXTERIOR
Stainless Steel Cladding (MT-04): M-2
GL-02 GL-03 GL-04
System includes all-glass entrance doors [GL-03] and three-side supported monolithic glass sidelites and vestibule glazing [GL-04].
GL-02: Typical Vision Glass IGU 38 mm [1-1/2"] insulating glass unit » 12 mm [1/2"] low iron HS laminated outer lite (6 mm [1/4"] + 6 mm [1/4"]) » 16 mm [5/8"] argon airspace » 10 mm [3/8"] low iron HS laminated inner lite (5 mm [3/16"] + 5 mm [3/16"])
Acceptable coatings: Uncoated
2.67** ^
0.82** ^
2550
4000
2550 x 3770
VESTIBULE 1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
137 x 70
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
GL-03: Glass Entrances 19 mm [3/4"] monolithic safety glass » 19 mm [3/4"] low iron FT
System is deadloaded at sill and anchored for wind at head.
GL-04: Vestibule Glass 19 mm [3/4"] monolithic glass » 19 mm [3/4"] laminated lite [8 mm [5/16"] HS low-iron...
BOTTOM RAIL
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
CONCEALED FLOOR CLOSER ** Published values ^ Coating, U-Value, and SHGC have not been reviewed / confirmed by Mechanical...
METAL GRATE WALK OFF MATT D
Metal Panel Aluminum Panel (MT-06): System consists of 4mm [3/16”] aluminum panels [type MT-05 or type MT-06, as indicated on drawings] attached to vertically-oriented A-3 anodized aluminum support channels anchored to continuous backup construction. Air, water, and vapor barrier shall be installed on the face of the backup construction, with continuous black scrim faced insulation installed outboard of the air barrier. Connections to backup construction to be thermally isolated. System incorporates continuous air seal closure/flashing to perimeter substrate.
GL-05
GL-05: Glass Display Cases n/a 25 mm [1"] laminated glass » 25 mm [1"] laminated lite [12 mm [1/2"] HS low-iron + 2.3 mm [0.090"] clear SGP + 12 mm [1/2"] HS low-iron]
n/a
n/a
Max panel 4100 width: 455 mm
n/a
n/a
SLOPE 2% TO DRAIN
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
Design and engineering of backup structure by others.
DW_1133_HEAD & SILL DETAIL - ENTRANCE GLASS DOOR
System also includes glass display cases [GL-05] mounted in W-D wall.
FACADE CONSULTANT
System is deadloaded at sill and anchored for wind itermitently...
Canopy
Metal Finish Types A-1 A-2 A-3 M-1 M-2
Type Glazing GL-01
Canopy Cladding System consists of 4mm [3/16”] aluminum panels [type MT-05 or Aluminum Panel (MT-05): type MT-05A, as indicated on drawings] attached to anodized A-1 aluminum support channels anchored to canopy framing as shown in Structural Drawings. Perforated Aluminum Panel (MT-05A): A-1
DW_1133_HEAD & SILL DETAIL - ENTRANCE GLASS DOOR n/a
n/a
n/a
n/a
n/a
TBD by Gensler
TBD by Gensler
n/a
02
SCALE: 1 : 4
n/a
PVDF, 3-coat system, custom color metallic Acrylic, 1-coat system, custom color FEVE, 1-coat system base powder coat, custom color; FEVE, 1-coat system topcoat, clear, to acheive 80% gloss or greater.
Date 1 2
Aliphatic Acrylic Polyurethane, custom color AISI No. 8 mirror non-directional finish
Location W-A Typical Vision Glass IGU
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
Finish 35 mm [1-3/8"] insulating glass unit » 10 mm [3/8"] low iron HS outer lite » 16 mm [5/8"] argon airspace » 10 mm [3/8"] low iron HS laminated inner lite (5 mm [3/16"] + 5 mm [3/16"])
CONCEALED HINGE GL-02
W-C Typical Vision Glass IGU
38 mm [1-1/2"] insulating glass unit » 12 mm [1/2"] low iron HS laminated outer lite (6 mm [1/4"] + 6 mm [1/4"]) » 16 mm [5/8"] argon airspace » 10 mm [3/8"] low iron HS laminated inner lite (5 mm [3/16"] + 5 mm [3/16"])
GL-03
W-C1 Glass Entrances
19 mm [3/4"] monolithic safety glass » 19 mm [3/4"] low iron FT
GL-04
W-C1 Glass Vestibule
18 mm [3/4"] monolithic laminated glass » 8 mm [5/16"] low iron HS » 1.52 mm [0.060"] SGP interlayer » 8 mm [5/16"] low iron HS
GL-05
W-D Glass Vitrine
25 mm [1"] laminated glass » 25 mm [1"] laminated lite [12 mm [1/2"] HS low-iron + 2.3 mm [0.090"] clear SGP + 12 mm [1/2"] HS low-iron]
PANIC HARDWARE AS REQ.
Seal/Signature
DOOR FINISH TO MATCH ADJ. W-D MATERIAL AND FINISH AND PROVIDED BY SAME FABRICATOR ALIGN MATCH FINISH AND PANEL SIZE
Metal Finish Types A-1 PVDF, 3-coat system, custom color metallic A-2 Acrylic, 1-coat system, custom color A-3 FEVE, 1-coat system base powder coat, custom color; FEVE, 1-coat system topcoat, clear, to acheive 80% gloss or greater. M-1 M-2 Aluminum MT-01 MT-02
SEE ELEVATION
12
ALIGN MATCH FINISH AND PANEL SIZE
Aliphatic Acrylic Polyurethane, custom color AISI No. 8 mirror non-directional finish
Project Name
HOLT RENFREW OGILVY W-B Custom Cut and Formed Metal Panel W-A Metal Panel
A-1 A-1
MT-03 MT-05 MT-05A MT-06 MT-08 MT-09 MT-10
W-A Mullion Canopy Cladding; W-A and W-D Return Panels Perforated MT-05 @ Canopy Cladding W-D Metal Panel W-A Shadowbox Reveal at W-D Metal Panel W-D Metal Panel at Existing Ogilvy Building
Exterior: A-1 Interior: A-2 A-1 A-1 A-3 A-1 A-1 A-1
Steel MT-04 MT-07
W-C Mullion Cladding Steel Truss
M-2 M-1
W-C Base; W-D Base and Head
Type: Jet Mist. Finish: TBD
Project Number
06.9964.000 Description
DOOR SCHEDULE, DOOR TYPES, WALL TYPES & FINISH SCHEDULES Scale
As indicated
Stone ST-01
DOOR TYPE B JAMB SCALE: 1 : 4
03
A-0002 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy
01
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
02 03 04 05
1
A
03 ________ ________ A-6100
2
2 ________ ________ A-4100
3
1 ________ ________ A-4100
4 P.L.
A
06 07 08 09
A.3
10
1997
07
850
LEVEL 07 69.41
494
200 50
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
FACE OF SCRIM TO QDLM FACADE 50 REVEAL 850 1097
P.L.
NEW ENTRY DOORS AND STOREFRONT GLAZING SYSTEM. NEW EXIT EGRESS DOOR. NEW VITRINE DISPLAYS. NEW SCHEDULED PANELS ON EXTERIOR WALL ASSEMBLY. NEW GLAZING SYSTEM WITH OUTRIGGER SUPPORT FOR SCRIM. FACE OF SCRIM. LINE OF NEW DLM SCRIM IN FOREGROUND NEW DLM CANOPY NEW SIDE COVER FOR GAP BETWEEN SCRIM TO QDLM NEW SIAMESE CONNECTION.
LEVEL 07 69.41
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
LEVEL 07 69.41
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
LEVEL 06 66.32
LEVEL 06 66.32
08 ________ ________ A-6000
LEVEL 06 66.32
INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
05 ________ ________ A-6000 121
23360 MT05
EXTERIOR LIGHTING CONSULTANT 4560
1440
4560
1440
4560
(3) EQ WALL TYPE A & A1
(1) WALL TYPE A1
(3) EQ WALL TYPE A & A1
(1) WALL TYPE A1
(3) EQ WALL TYPE A & A1
3404
1656
3406
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
1748
02 ________ ________ A-6100
INTERIOR LIGHTING CONSULTANT LEVEL 05 62.06
1608
MT02
LEVEL 05 62.06
LEVEL 05 62.06
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
W-A1
1520
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
3218
09
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
06
LEVEL 04 57.75
MT02
GL01
MT02
GL01
05
GL01
MT02
05
05
02 ________ ________ A-6000
4806
02 ________ ________ A-6000
MT02
22034
LEVEL 04 57.75
W-A1
W-A1
W-A
W-A
W-A1
W-A
W-A1
ALIGN PANEL REVEALS WITH W-B SCRIM REVEALS
W-B
STRUCTURAL ENGINEER LEVEL 04 57.75
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
W-A
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
MT05
HISTORIC PRESERVATION CONSULTANT
LEVEL 03 53.00
LEVEL 03 53.00
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
LEVEL 03 53.00
CODE CONSULTANT
4707
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
1366
3 ________ ________ A-4100
W-A1
3618 01
1447
3 (EQ) MT-5 CANOPY PANELS 3873
04
04
W-D
SEISMIC JOINT
W-C1 MT06
GL05
GL05
W-C1
002
001
02
02
TOP OF CANOPY 46.89
MT05
TOP OF CANOPY 46.89
Date 1 2 3
Description
04/01/2016 Issue for Revised Schematic Pricing Pkg 08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
W-C
100
930
3588
W-D
________ ________ 02 A-6402
LEVEL 02 47.71 50
30 664 140 554
MT05
150
MT05
TOP OF CANOPY 46.89
LEVEL 02 47.71 08
MT02
50 552
02 ________ ________ A-6202
01
10
MT06
2165
3618
01 ________ ________ A-6402
LEVEL 02 47.71
GL02 GL04
GL03
GL04
1210
03 ENTRY LANDING 43.20 LEVEL 01 42.75
ENTRY LANDING 43.20
ST01
150
MT09
ENTRY LANDING 43.20
LEVEL 01 42.75
MT09
1 (EQ) W-D 9 (EQ) W-D
2 (EQ) W-D
EQ.
1900 3600
4 (EQ) W-D
EQ.
2 (EQ) W-D
2 (EQ) W-D 2 (EQ) W-D
10030
4982
4 (EQ) W-C
11 (EQ) WALL TYPE D
Seal/Signature
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
ENLARGED DLM FACADE ELEVATIONS
Scale
1 : 50
CANOPY EAST ELEVATION SCALE: 1 : 50
3
DLM FACADE ELEVATION - INNER LAYER GLAZING SCALE: 1 : 50
02
NORTH FACADE ELEVATION @ MTL CAP SCALE: 1 : 50
01
A-2000 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
1
2
A
2 ________ ________ A-4100
03 ________ ________ A-6100
3
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
4
1 ________ ________ A-4100
MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
23600
16500
3550
(2) EQ. WALL TYPE B
(11) EQ. WALL TYPE B
(2) EQ. WALL TYPE B
ARCHITECT OF RECORD LEVEL 07 69.41
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
VIF ALIGN WITH TOP OF PARAPET
LEVEL 07 69.41
3550
MT10
INTERIOR DESIGNER
LEVEL 06 66.32
LEVEL 06 66.32
ALIGN REVEAL AND SCRIM OUTSIDE FAC
900 EQ
MT01
VIF
EXTERIOR LIGHTING CONSULTANT
(6) EQ. WALL TYPE B
7976
W-B
EQ
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT 02 ________ ________ A-6100
LEVEL 05 62.06
LEVEL 05 62.06
1776
1303
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
W-B
LEVEL 04 57.75
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
LEVEL 04 57.75 MT01
MT01
MT01
VERTICAL TRANSPORTATION ENGINEERS
MT01
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
26189
W-B
02 ________ ________ A-6000
(9) EQ. WALL TYPE B
W-B
W-B
12649
W-B
12649
20712
26039
MT10
MATCH REVEALS WITH ADJACENT PERPENDICULAR W-B SCRIM PANELING
STRUCTURAL ENGINEER
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
LEVEL 03 53.00
CODE CONSULTANT
LEVEL 03 53.00
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
1776
01 ________ ________ A-6402
02 ________ ________ A-6202
3 ________ ________ A-4100
MT01
LEVEL 02 47.71
Date
50
06 ________ ________ A-6500
1409
1409
1404
LEVEL 02 47.71
554
1
TOP OF CANOPY 46.89
2
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
EQ
3091
3587
2969
1297 ENTRY LANDING 43.20 LEVEL 01 42.75
ENTRY LANDING 43.20 150
150
EQ
TO LEVEL 1
PANEL REVEAL, TYP
930
MT10
3501
PANEL TERMINATES AT FACE OF EMSEAL COVER
1210
ALIGN REVEAL WITH BOTTOM OF CANOPY
ALIGN WITH W-D AT DLM FACADE
150
552
TOP OF CANOPY 46.89
Description
LEVEL 01 42.75
Seal/Signature
1
2
3
4
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
ENLARGED DLM FACADE SCRIM
Scale
1 : 50
EAST FACADE ELEVATION @ MTL CAP1 SCALE: 1 : 50
2
DLM FACADE ELEVATION - OUTER LAYER SCRIM SCALE: 1 : 50
1
A-2001 © 2016 Gensler
SHEET NOTES 2
3
________ ________ 01 A-6300
02
150
2599
101
02 03
A-6300
824
02
________ ________ 2 A-6201
04
________ ________ 01 A-6401 404
05
________ ________ 03 A-6401
________ ________ 02 A-6401
850
1900
2507
850
01
99
225
ALIGN
75
174
200
04
398 EXIST. VIF
05
________ ________ 01 A-6201
TYP @ TYPE C
002
13
03
15 16
A
001 08
03 A-0002
17 18
Sim 01
2
10 11 12 13 14
A.3
236
________ ________ 03 A-6600
1560
1200 MIN
_
2316
________ ________ 3 A-6402
100
900
900
09
2266
1549
75
3600
A-2000
________ ________ 01 A-6600
3
A-6202 01
13650
403
4
99
1
01 02 03 04 05 06 07 08
19 20
A-2000
A-2001 4985
3
3600
10030
4986
NEW "TYPE C" ASSEMBLY, TYP. NEW EXIT EGRESS DOOR. NEW "TYPE D" ASSEMBLY, TYP. NEW VITRINE DISPLAYS. LINE OF NEW CANOPY BELOW. LINE OF NEW DLM SCRIM. SCRIM OPENINGS TO GLAZING. SCHEDULED METAL PANEL FRAME AND COVER CAP BETWEEN SCRIM AND CURTAIN WALL. NEW "TYPE A" & "TYPE A1" ASSEMBLY WITH OUTRIGGER SUPPORT FOR SCRIM. QDLM FACADE. (NIC) METAL REVEAL. NEW CANOPY DRAINAGE AS REQD. NEW SIAMESE CONNECTION AS PER CODE. CEILING TROFF WITH INTEGRATED DIRECTIONAL LIGHTS AND HOOKS FOR DISPLAY VISUAL HANGING. CUSTOM TROFF TO BE COORDINATED WITH MTL. CEILING PANEL. FIXTURES ARE NOT IN CURRENT SCOPE. TYPICAL FOR ALL INTERIOR LIGHTS OTHER THAN VESTIBULE. JOINT AT METAL PANEL RAINSCREEN NEW RECESSED LINEAR HEAT LAMP AT CANOPY. COORDINATE WITH MECHANICAL ENGINEERING DRAWINGS, TYP. NEW RECESSED LIGHT AT CANOPY, TYP. DRAIN TO SANITARY MAIN LINE WITHIN CANOPY STRUCTURE. RUN PARALLEL TO CANOPY STRUCTURE EMSEAL AT BUILDINGS JOINT AS REQUIRED EXISTING OGILVY BUILDING MASONRY, NIC
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
02
1
A-2000
A-2001
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
FACADE PLAN - LEVEL 01
01
SCALE: 1 : 50
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
1
2
3
4
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
A.5 EQ
EQ
VERTICAL TRANSPORTATION ENGINEERS
75
14
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
2341
A.3
75
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
05
03
01
EQ
A 03
CODE CONSULTANT 3673
3673
15
EQ
17
EQ
16
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
EQ1
950
950
849
10030
4985
8 EQ
4 EQ
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
FACADE REFLECTED CEILING PLAN - LEVEL 01
02
SCALE: 1 : 50
Date 1 2 3
1
2
3
Description
04/01/2016 Issue for Revised Schematic Pricing Pkg 08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
4
A.3
397 2899
1723
331
Seal/Signature
09 TYP. 10
18
900
15
A
08
200
05
200
19
900
1997
11
07
18 A-2001
01 15
3873
3
A-2000
Project Name
15
CANOPY BELOW
12 A-2000
12
HOLT RENFREW OGILVY
2773
2
07
06
3873
20
TYP. 08
TYP.
1
Project Number 05
A-6601
06.9964.000
02
Description A-2000
3550
4500
(2) EQ. WALL TYPE A1 & B
(3) EQ. WALL TYPE A
1500
4500 (3) EQ. WALL TYPE A
ENLARGED DLM FACADE - PLANS 1500
4500
3549
(3) EQ. WALL TYPE A
Scale
23600
1 : 50
FACADE PLAN - LEVEL 02 SCALE: 1 : 50
03
A-4000 © 2016 Gensler
1
2
3
SHEET NOTES
4
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest
01 02 03 04 05
A-6202
06 07 08 09 10 19
A.3
02
NEW DLM SCRIM. Montréal, (Québec) Canada QDLM FACADE. (NIC) H3G 1P7 OUTRIGGER SUPPORT SCHEDULED METAL PANEL FRAME AND COVER CAP BETWEEN SCRIM AND CURTAIN WALL. REMOVE PORTION OF EXISTING MASONRY. REPLACE EXTERIOR ENVELOPE WITH METAL PANEL ON NEW MASONRY INFILL PER STRCUCTURAL ENGINEER COORDINATION. TIE BACK TO EXISTING O ALIGN WITH ADJACENT FACE OF STONE. OWNER NEW DRAINAGE AS REQD. NEW PARAPET COPING, FLASHING, & WATERPROOFING MEMBRANE AS REQD. 60 Bloor Street West NEW "TYPE A" & "TYPE A1" ASSEMBLY WITH OUTRIGGER SUPPORT FOR SCRIM. Suite 300 SCRIM OPENINGS TO GLAZING. Toronto, (Ontario) Canada LINE OF METAL FINISH PANEL JOINT. M4W 3B8 EMSEAL AT BUILDINGS JOINT AS REQUIRED Telephone 514.842.7711
DLM FACADE
08 TYP.
900
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
A 04
05
A-2000
419 EXG. STONE VIF
200
901
2000
MASTER ARCHITECT
TYP. 04
09 2
10
01
TYP.
09 01
________ ________ 01 A-6001
A-2001
ARCHITECT OF RECORD
TYP. A-2000
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
3
________ ________ 02 A-6001 INTERIOR DESIGNER
02
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
A-2000
EXTERIOR LIGHTING CONSULTANT
FACADE PLAN - LEVEL 03. LEVEL 04
01
SCALE: 1 : 50
1
2
3
4
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
A.3
02
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
08 TYP.
STRUCTURAL ENGINEER
05
09
04
3550
4500
(2) EQ. WALL TYPE A1 & B
(3) EQ. WALL TYPE A
A
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
04
200
19
2000
900
________ ________ 02 A-6001
________ ________ 01 A-6001
10
09
TYP. 4500
1500
1500
(3) EQ. WALL TYPE A
399
4500
3550
(3) EQ. WALL TYPE A
(2) EQ. WALL TYPE A1 & B
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
23600
HISTORIC PRESERVATION CONSULTANT
FACADE PLAN - LEVEL 04
02
SCALE: 1 : 50
1
2
3
8855
8265
826
1721
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
4 5750
1748 55
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
614
1440
1651
1742
1099
FACADE CONSULTANT
555
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
A-6202
A.3 02 06
07
A
2
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
04 3
19
1
853
03
Date 2000
50
1100
06
3
07
05
397
01
23600
01 2 A-2000
A-2001
A-2000
________ ________ 01 A-6001
3
________ ________ 02 A-6001
FACADE PLAN - LEVEL 05
03
02
SCALE: 1 : 50 A-2000
1
2
3
4
Seal/Signature
A-6202
A.3 02 3
Project Name
2000
HOLT RENFREW OGILVY A
OPEN TO BELOW
Project Number
06.9964.000
04 200
19
900
601
1100
299
50 1100
TYP.
Description
05
ENLARGED DLM FACADE - PLANS
01 2 A-2000
________ ________ 01 A-6001
A-2001
01
A-2000
3
Scale
________ ________ 02 A-6001 323
1 : 50
23600 02 A-2000
FACADE PLAN - LEVEL 06 SCALE: 1 : 50
04
A-4001 © 2016 Gensler
SHEET NOTES 01 02 03 04 05 06 07 08 09 10
NEW EGRESS DOORS NEW STANDPIPE NEW METAL PANEL ON STUD WALL NEW CANOPY, SEE ALSO STRUCTURAL NEW GLAZING SYSTEM GAP IN BETWEEN SCRIM TO DLM GLAZING TO BE CAPPED WITH SCHEDULED ASSEMBLY/FINISH. QDLM FACADE. (NIC) NEW CANOPY DRAINAGE AS REQD. NEW DRAINAGE AS REQD. PROPERTY LINE
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
A
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
A
EXTERIOR LIGHTING CONSULTANT
PROPERTY LINE
LEVEL 07 69.41
LEVEL 07 69.41
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
PROPERTY LINE
2661
2795
INTERIOR LIGHTING CONSULTANT
07
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
07 LEVEL 06 66.32
LEVEL 06 66.32
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
7976
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
4255
04
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
09
________ ________ 01 A-6002 LEVEL 05 62.06
1650
VERTICAL TRANSPORTATION ENGINEERS
06
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
4311
06
3176
200 601
200
900
366 LEVEL 04 57.75
LEVEL 04 57.75
900
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
22034
200
HISTORIC PRESERVATION CONSULTANT
299 2921
LEVEL 05 62.06
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
4806
BEYOND
04
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
3378
12649
4806
FACADE CONSULTANT
05 03 05
508 END OF PLATE LEVEL 03 53.00
LEVEL 03 53.00
Date 1 2
A.3
A.5
3
B
04/01/2016 Issue for Revised Schematic Pricing Pkg 08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
3835
5230
4686
A
Description
________ ________ 05 A-6500 508 END OF PLATE
LEVEL 02 47.71
1409
LEVEL 02 47.71 205 TOP OF CANOPY 46.89 04
TOP OF CANOPY 46.89
TOP OF CANOPY 46.89
99
02
1778 TO CANOPY ANCHOR
02
03
174
Seal/Signature
4963
________ ________ 8 A-6400 01 3588
10 3588
125
3549
554
3673
LEVEL 02 47.71
08
02
10
VESTIBULE
01
01
ENTRY LANDING 43.20 LEVEL 01 42.75
Project Name
LEVEL 01 42.75
LEVEL 01 42.75
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
WALL SECTIONS - DLM
Scale
1 : 50
SECTION - QDLM EGRESS SCALE: 1 : 50
3
SECTION - SCRIM OPENING/ENTRANCE SCALE: 1 : 50
2
SECTION - SCRIM/DISPLAY WINDOW SCALE: 1 : 50
1
A-4100 © 2016 Gensler
A
A ________ ________ 10 A-6000
366
01 02 03 04 05
________ ________ 09 A-6000
04
04
SHEET NOTES
05 ________ ________ A-6000
08 ________ ________ A-6000
LEVEL 04 57.75
LEVEL 04 57.75
LEVEL 04 57.75
NEW "TYPE A" ASSEMBLY, TYP. NEW "TYPE A1" ASSEMBLY, TYP. NEW "TYPE B" ASSEMBLY, TYP. SCRIM STRUCTURAL SUPPORT, TYP. FIRE STOP ASSEMBLY @ EDGE OF FLOOR SLAB, TYP.
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
498
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
137
MASTER ARCHITECT 01
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD 03
02 ________ ________ A-6000
02 ________ ________ A-6000
INTERIOR DESIGNER
REFER TO SHEET A-2000
VARIES PER FLOOR
REFER TO SHEET A-2000
VARIES PER FLOOR
02 ________ ________ A-6000
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
03
W-A1
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
W-A
W-A
MT02
GL01
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
02
05
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
05
SCRIM TRUSS DESIGN IN PROGRESS
LEVEL 03 53.00
LEVEL 03 53.00
LEVEL 03 53.00
04
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
TYPE A & A1 - AXONOMETRIC
11
SCALE:
TYPE A1 - SECTION
08
SCALE: 1 : 20
TYPE A - SECTION
05
SCALE: 1 : 20
TYPE A & A1 - ELEVATION
01
SCALE: 1 : 20
VARIES PER LOCATION
4560
1440 TYP.
REFER TO SHEET A-2000
(3) EQ. WALL TYPE A
(1) WALL TYPE A1
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
GL-01
________ ________ 03 ________ ________ 04 A-6000 A-6000
A
MT-03
02
Fire Safing and Smoke Seal 268
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
04
HISTORIC PRESERVATION CONSULTANT
________ ________ 06 A-6000
03
01
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
Interior Finish ________ ________ 07 A-6000
CODE CONSULTANT
TYPE A & A1 - PLAN 418
W-B Truss See Struct. Dwgs.
02
SCALE: 1 : 20
98
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
W-B Wind Load Bracket Coordinate with Truss. See Struct. Dwgs.
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Steel Anchor Plate (Below) Dimensions to be Coordinated with Stuct. Eng.
Galvanized Steel Backpan
Extend of MT-01 Folds MT-01
MT-03
Aluminum Panel Support Bracket (Beyond)
Galvanized Steel Backpan
Galvanized Steel Backpan
Galvanized Steel Backpan
Mineral Wool Insulation
Mineral Wool Insulation
Mineral Wool Insulation Date 98
MT-03
98
Interior Finish
MT-03
98
Steel Anchor Assembly
Mineral Wool Insulation
1
MT-08
268 16
203 32
33
09
SCALE: 1 : 5
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
268
268 16
W-A Section @ Glass
366
366
2
Description
16
MT-08
1100
900
MT-02
Aluminum Adapter Clip
Aluminum Adapter Clip
Wind Load Connection to Truss (See Structural Drawings)
Interior Finish
GL-01
W-A Plan @ Anchor
03
SCALE: 1 : 5
727
Panel Support Bracket (Coordinate with Truss)
Seal/Signature
737
Edge of Slab
900
W-B Truss See Struct. Dwgs.
W-B Truss See Struct. Dwgs. MT-03
1100
1100
418
W-B Truss See Struct. Dwgs.
GL-01 Aluminum glazing adapter
MT-02
737
148
268
Extent of Truss
Wind Load Connection to W-B Truss (See Struct. Dwgs.)
Fire Safing and Smoke Seal 200
Extent of W-B Truss See Struct. Dwgs
70
Project Name
98
MT-01
203 268
MT-01
06.9964.000 Description
148
Extend of MT-01 Folds
Project Number
33
Galvanized Steel Backpan
Extent of W-B Truss See Struct. Dwgs.
Wall Type 'A', 'A1'
32
W-B Wind Load Bracket Coordinate with Truss. See Struct. Dwgs.
Extent of W-B Truss See Struct. Dwgs
366
HOLT RENFREW OGILVY
MT-01 16
Aluminum Panel Support Bracket Steel Anchor Assembly
70
348
12
GL-01
Interior Finish
Aluminum glazing adapter
Scale
200
Mineral Wool Insulation MT-02
Max Extents of MT-01 Folds
As indicated
Max Extents of MT-01 Folds
50
W-A Section @ Metal Panel SCALE: 1 : 5
10
W-A Plan @ Mtl Pnl @ Wind Load Bracket SCALE: 1 : 5
07
W-A Plan @ Window Surround SCALE: 1 : 5
06
W-A Plan @ Glass SCALE: 1 : 5
04
A-6000 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
Interior Construction See Arch. Dwgs.
CODE CONSULTANT
Seismic Joint Coordinate with Arch. Dwgs.
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
Galvanized Steel Backpan Mineral Wool Insulation
Galvanized Steel Backpan
FACADE CONSULTANT
Mineral Wool Insulation
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Refer to Arch. Dwgs. for Joint Movement
TBD
MT-05
Extent of Truss MT-01
MT-02
MT-05
Aluminum Adapter Clip
1
Aluminum Adapter Clip
Description
10/31/2016 ISSUE FOR 100% DD
Wind Load Connection to Truss (See Structural Drawings)
Wind Load Connection to Truss (See Structural Drawings)
W-D System @ Ogilvy Masonry Wall Details Pending Coordination of Backup Structure
Date
MT-02
Extent of Truss
Panel Support Bracket (Coordinate with Truss)
W-B Truss See Struct. Dwgs.
W-B Truss See Struct. Dwgs.
Extent of W-B Truss See Struct. Dwgs.
Extent of W-B Truss See Struct. Dwgs.
Seal/Signature
MT-01
MT-01
Project Name
Max Extents of MT-01 Folds
HOLT RENFREW OGILVY
Max Extents of MT-01 Folds 50
Project Number
50
06.9964.000 Description
WALL TYPE 'A', 'A1' PLAN DETAILS
Scale
1:5
W-A Plan @ Existing Building SCALE: 1 : 5
02
W-A Plan @ Shear Wall SCALE: 1 : 5
01
A-6001 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
Concrete curb
ARCHITECT OF RECORD
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
340
MT-02
Drainage Assembly See QDLM Dwgs. Adjacent facade system See QDLM Dwgs.
Steel Parapet Support
350
Steel Gutter Support 780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
Anchor for W-A and W-B To be coordinated with truss design. See Struct. Dwgs. INTERIOR DESIGNER
Waterproof Membrane
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
W-B Truss See Struct. Dwgs.
EXTERIOR LIGHTING CONSULTANT
Max Extent of MT-01 Folds 247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
MT-01 Stainless Steel Gutter w/ Heat Trace
INTERIOR LIGHTING CONSULTANT 300
Interior finish 335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
50
MT-03 MT-05
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
GL-01
Solid Portion of MT-01
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
STRUCTURAL ENGINEER
W-A Section @ L5 Parapet
01
SCALE: 1 : 10
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
1100 200
900
268
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
2% SLOPE
MT-05A (Perforated) 50
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
W-B Truss See Struct. Dwgs.
FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
MT-01 MT-05A (Perforated)
Stainless Steel Insect Screen
Note: Coordinate Structural Framing for Canopy with Under-slab Anchor
Date 1
Description
10/31/2016 ISSUE FOR 100% DD
Structural Thermal Break Coord. w/ Struct. Dwgs.
MT-05
ST-01
Interior Finish
MT-06
Canopy Section @ W-A & W-D SCALE: 1 : 10
02
Seal/Signature
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
WALL TYPE A, A1 SECTION DETAILS
Scale
1 : 10
A-6002 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy
01
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
02 03 04 05
NEW 5MM THK. ANODIZED METAL PANEL SCRIM ASSEMBLY, TYP. NEW IGU CURTAIN WALL ASSEMBLY, TYP. NEW MTL PANEL ASSEMBLY, TYP. SCRIM SUPPORT TRACK/FRAME SCRIM TRUSS, TYP. SEE ALSO STRCUTURAL DRAWINGS
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
QDLM FACADE (N.I.C), TYP.
MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 NEW "TYPE B" ASSEMBLY, TYP.
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
NEW "TYPE A1" ASSEMBLY, TYP.
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
TYPE B - AXONOMETRIC
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
01
SCALE:
Date 1
A
2
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
03 ________ ________ A-6100
_200MM
01 04
LEVEL 05 62013 Line of Gutter Beyond 2% Slope
A
50
5MM THK. MTL. PANEL
300
Cut portion of MT-01
GG
Solid portion of MT-01 02 ________ ________ A-6100
Seal/Signature
05
01
04
02
05
LEVEL 05 62.06
LEVEL 04 62013
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000
03
Description
Wall Type "B" AXONOMETRIC DIAGRAM SCALE: N.T.S Scale
As indicated
TYP Scrim Panel_PATTERN TBD SCALE: 1 : 60
05
Elevation Diagram of Gutter at L5 SCALE: 1 : 50
04
TYPE B - SECTION SCALE: 1 : 20
03
TYPE B - PLAN SCALE: 1 : 20
02
A-6100 © 2016 Gensler
________ ________ 05 A-6200
A.3
SHEET NOTES
Holt Renfrew | Ogilvy
01
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
NEW "TYPE C" ASSEMBLY, TYP.
DLM FACADE
A
04 ________ ________ A-6200
OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD 01
NEW "TYPE C" ASSEMBLY, TYP.
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 02 ________ ________ A-6200
3617
STONE PLYNTH AT SHOW WINDOW SIDEWALK
W-C
INTERIOR DESIGNER
VARIES PER LOCATION
02 ________ ________ A-6200
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
EXTERIOR LIGHTING CONSULTANT
550
ENTRY LANDING 43.20
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
ENTRY LANDING 43.20
INTERIOR LIGHTING CONSULTANT 65
LEVEL 01 42.75
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
________ ________ 06 A-6200
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
STRUCTURAL ENGINEER
TYPE C - AXONOMETRIC
07
SCALE:
TYPE C - SECTION
04
SCALE: 1 : 20
TYPE C - ELEVATION
01
SCALE: 1 : 20
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
________ ________ 03 A-6200
Refer to Arch. Dwgs. for Waterproofing Details
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
A 01
2507 TYP.
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
TYPE C - PLAN
02
SCALE: 1 : 20
Structural Thermal Break Coord. w/ Struct. Dwgs.
FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Interior Finish MT-04
MT-05 GL-02
Date 1 2
W-C Section @ Head
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
05
SCALE: 1 : 4
21
GL-02 MT-04 Steel Tee Heating Element
ST-01
MT-04
137
Stainless Steel Shoe
Seal/Signature
38
43
Interior Finish
225
16
225
VARIES
68
Project Name
70
HOLT RENFREW OGILVY Project Number
ST-01 Below
Rigid Insulation
06.9964.000
GL-02
Below-Grade Waterproofing
Ceramic Frit Border on #2 Surface 25
Description
Wall Type "C"
81
Scale
As indicated
W-C Section @ Sill SCALE: 1 : 4
06
W-C Typical Plan SCALE: 1 : 4
03
A-6200 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
GL-04
DLM FACADE Metal Stud See Struct. Dwgs.
OWNER
137
MT-04
38
Steel Tee
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
MT-06
16
MASTER ARCHITECT
68
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
225
225
172
GL-04
455
12
ARCHITECT OF RECORD
ST-01 Below
ST-01 GL-02
GL-02 Ceramic Frit Border on #2 Surface
W-C Plan @ Vestibule (W-C1) SCALE: 1 : 5
MT-06 780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
Mineral Wool Insulation Air Vapor Barrier Exterior Grade Sheathing
2
W-C Plan @ W-D SCALE: 1 : 5
01
INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Date 1
Description
10/31/2016 ISSUE FOR 100% DD
Seal/Signature
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
WALL TYPE 'C' PLAN DETAILS
Scale
1:5
A-6201 © 2016 Gensler
3
04 ________ ________ A-6200
2
02 ________ ________ A-6202
SHEET NOTES
Holt Renfrew | Ogilvy
01
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
02 03 04
01 ________ ________ A-6402
05 06
NEW ENTRY DOORS AND STOREFRONT GLAZING SYSTEM. NEW STONE FINISH FOR COLUMN ENCLOSURE. LINE OF METAL FINISH PANEL JOINT NEW CANOPY STRUCTURES. REFER TO STRUCTURE ENGINEER'S DWG. NEW CANOPY INTERIOR FINISH CEILING FOR FUTURE COORDINATION
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
04
CANOPY
03
MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
MT05
150
559
TOP OF CANOPY 46.89
05 150
ARCHITECT OF RECORD
150
150
696 02
01
559
150
02
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
01
INTERIOR DESIGNER W-C
W-C
W-C
W-C1
W-C1
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
2973
W-C
GL02
MT06
GL04
GL03
MT06
GL03
MT06
3288
MT06
ACCESS PANEL FOR FUTURE COORDINATION
02 ________ ________ A-6200
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
ST01 ST01
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
150
65
550
INTERIOR LIGHTING CONSULTANT
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
1774 4 (EQ) W-D
STRUCTURAL ENGINEER
OVERALL INT. ELEVATION - LV 1
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
01
SCALE: 1 : 20
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
A.5
A.3
A
A
A.3
Date 1
10/31/2016 ISSUE FOR 100% DD
TOP OF CANOPY 46.89
150
TOP OF CANOPY 46.89
Description
75
05
75
06 150
EQ
EQ
EQ
EQ
06 MT05
EQ
MT05
MT06
01
02
2812
MT06
02 ________ ________ A-6200
Seal/Signature
174 225
636
Project Name
HOLT RENFREW OGILVY
ENTRY LANDING 43.20
Project Number
ST01
LEVEL 01 42.75
06.9964.000
LEVEL 01 42.75
Description
WALL TYPE 'C' INTERIOR ELEVATION & SECTION
Scale
1 : 20
Elevation 2 - d SCALE: 1 : 20
3
INTERIOR ELEVATION AT DISPLAY WINDOW SCALE: 1 : 20
02
A-6202 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy
01
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
02 03 04 05
NEW FRAMELESS ENTRY DOOR ASSEMBLY AT VESTIBULE. NEW FRAMELESS GLAZING SYSTEM AT VESTIBULE. NEW FRAMELESS ENTRY DOOR ASSEMBLY AT STOREFRONT NEW DLM CANOPY. NEW SENSORMATIC MATS AT VESTIBULE.
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711 MASTER ARCHITECT
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
A
A.3
A.3
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
A
EXTERIOR LIGHTING CONSULTANT
TOP OF CANOPY 46.89
TOP OF CANOPY 46.89
________ ________ 05 A-6600
________ ________ 04 A-6600
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
________ ________ 03 A-6600 3513 1859
784
INTERIOR LIGHTING CONSULTANT
150
871
04
04
03
01
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
________ ________ 6 A-6600 01
W-C1
A.3
03
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
2216
02
MT06
MT06
05
03
A-6300
GL04
04 1900
STRUCTURAL ENGINEER
1403
850
02 ________ ________ A-6200
3588
3588
W-D
850
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
A ________ ________ 02 A-6401
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
________ ________ 2 A-6201
ST01
05
HISTORIC PRESERVATION CONSULTANT
05 LEVEL 01 42.75
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
LEVEL 01 42.75
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
2 FACADE CONSULTANT
SCALE: 1 : 20
05
VESTIBULE ELEVATION
03
SCALE: 1 : 20
2
Callout (2) of FACADE PLAN - LEVEL 01
01
SCALE: 1 : 20
2
06 ________ ________ A-6500
06 ________ ________ A-6500
Date 1 2
W-C1
W-C1
GL04 GL04
GL03
02
01
GL03
GL04
02
02
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
W-C1
W-C1
3588
VESTIBULE ELEVATION
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
01
GL03
GL04
02
Seal/Signature
Project Name ENTRY LANDING 43.20
ENTRY LANDING 43.20
HOLT RENFREW OGILVY
ST01
LEVEL 01 42.75
Project Number
LEVEL 01 42.75
06.9964.000 Description
VESTIBULE WALL TYPE 'C1'
Scale
1 : 20
VESTIBULE ELEVATION SCALE: 1 : 20
04
VESTIBULE ELEVATION SCALE: 1 : 20
02
A-6300 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy
01 02
1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
NEW "TYPE D" ASSEMBLY, TYP. REVEAL
DLM FACADE OWNER
A
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
04 ________ ________ A-6400
MASTER ARCHITECT ________ ________ 8 A-6400
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
3588
01
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 LEVEL 01 42.75
LEVEL 01 42.75
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
________ ________ 9 A-6400
STRUCTURAL ENGINEER
TYPE D - AXONOMETRIC
07
SCALE:
TYPE D - SECTION
04
SCALE: 1 : 20
TYPE D - ELEVATION
01
SCALE: 1 : 20
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
Structural Thermal Break Coord. w/ Struct. Dwgs.
CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
MT-05
Stainless Steel Insect Screen
Interior Finish
A
01
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
ST-01
________ ________ 10 A-6400
MT-06
Date 1
Description
10/31/2016 ISSUE FOR 100% DD
1
W-D Section @ Head
8
SCALE: 1 : 4
TYPE D - PLAN
02
SCALE: 1 : 20
334 150
184
Exterior Grade Sheathing Air Vapor Barrier Mineral Wool Insulation Seal/Signature
Metal Panel Support Framing MT-06
Metal Framing, See Struct. Dwgs.
64
Stainless Steel Insect Screen
Project Name
HOLT RENFREW OGILVY ST-01
Project Number
Rigid Insulation
06.9964.000
150
VARIES
MIN 150
66
Below-Grade Waterproofing
Description
Wall Type "D" 12 83
443
12
455
Exterior Grade Sheathing
Scale
Air Vapor Barrier Mineral Wool Insulation
As indicated
MT-06
W-D Section @ Sill SCALE: 1 : 4
9
W-D Typical Plan SCALE: 1 : 4
10
A-6400 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
See Struct. Dwgs.
Seismic Joint Coordinate with Arch. Dwgs.
Interior Construction See Arch. Dwgs.
Metal Framing, See Struct. Dwgs.
176
DLM FACADE
Metal Stud See Struct. Dwgs.
OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
MT-05
MT-06
16
MT-06
188
106
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
44
166
171
250
MASTER ARCHITECT
VIF
12
455
12
455
455
ARCHITECT OF RECORD
TBD
Refer to Arch. Dwgs. for Joint Movement MT-06
MT-06
Exterior Grade Sheathing Air Vapor Barrier Mineral Wool Insulation MT-06
Mineral Wool Insulation
Metal Framing, See Struct. Dwgs.
GL-04
Air Vapor Barrier Exterior Grade Sheathing
W-D System @ Ogilvy Masonry Wall Details Pending Coordination of Backup Structure
W-D Plan @ Existing Building SCALE: 1 : 5
03
W-C1 Plan @ W-D SCALE: 1 : 5
02
W-D Plan @ Shear Wall SCALE: 1 : 5
Shear Wall, See Struct. Dwgs.
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
Metal Framing Exterior Grade Sheathing Air Vapor Barrier Mineral Wool Insulation MT-06
INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
01
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
STRUCTURAL ENGINEER
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021 VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Date 1
Description
10/31/2016 ISSUE FOR 100% DD
Seal/Signature
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
WALL TYPE 'D' PLAN DETAILS
Scale
1:5
A-6401 © 2016 Gensler
SHEET NOTES
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
A
DLM FACADE
A
OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
847
MASTER ARCHITECT 616
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
1447
74
ARCHITECT OF RECORD
930
890
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 05
INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611 04
1210
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100 LEVEL 01 42.75
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
VITRINE - SECTION
04
SCALE: 1 : 5
TYPE D - SECTION (VITRINE)
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
01
SCALE: 1 : 20
STRUCTURAL ENGINEER
04 ________ ________ A-6402
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
930
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
890
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
930
890
CODE CONSULTANT
FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Date 1 2
VITRINE- ELEVATION
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
02
SCALE: 1 : 5
Metal Framing Exterior Grade Sheathing Air Vapor Barrier Mineral Wool Insulation
MT-06
Seal/Signature
GL-05 Metal Framing, See Struct. Dwgs.
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
GL-05 Exterior Grade Sheathing
WALL TYPE 'D' VITRINE DETAILS
Stainless Steel Cylinder lock
Air Vapor Barrier Mineral Wool Insulation
Scale
MT-06
W-D Section @ Display Case SCALE: 1 : 5
5 W-D Plan @ Display Case SCALE: 1 : 5
As indicated
3
A-6402 © 2016 Gensler
SHEET NOTES 1100
200
900
02 03 07 08 09 10 11 12 13 14
268
NEW DLM CANOPY LINE OF NEW "TYPE B" ASSEMBLY ABOVE. NEW DOOR ASSEMBLY. MET. GRATE WALK OFF MATT. CONCEALED FLOOR CLOSER. BOTTOM RAIL. TOP RAIL NEW CANOPY DRAINAGE. REFER TO STRUCTURAL DRAWING FOR DETAIL. NEW RECESSED LIGHT AT CANOPY, TYP
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
2% SLOPE MASTER ARCHITECT
MT-05A (Perforated)
50
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101 INTERIOR DESIGNER
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
W-B Truss See Struct. Dwgs.
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
INTERIOR LIGHTING CONSULTANT
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
MT-01
MT-05A (Perforated) STRUCTURAL ENGINEER
MT-05A (Perforated)
Refer to Arch. Dwgs for Waterproofing Details Refer to Struct. Dwgs for Framing Details TOP OF CANOPY 46.89
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
Note: Coordinate Structural Framing for Canopy with Under-slab Anchor
224
Stainless Steel Insect Screen
VERTICAL TRANSPORTATION ENGINEERS
588
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
216
Structural Thermal Break Coord. w/ Struct. Dwgs.
HISTORIC PRESERVATION CONSULTANT
148
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
MT-05 Interior Finish MT-05 FACADE CONSULTANT
GL-02
05
Canopy Section @ Drain
04
SCALE: 1 : 5
Canopy Section @ W-A & W-C
01
SCALE: 1 : 5
A
________ ________ 01 A-6500
A.3
Date
LEVEL 02 47.71
________ ________ 05 A-6500
1
________ ________ 04 A-6500
2
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
03 12
13 TOP OF CANOPY 46.89
50
SCALE: 1 : 5
13 14
3673
02 11
Seal/Signature
07
3588
Canopy Section @ End
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description 10 09
CANOPY PLANS AND SECTIONS 08 LEVEL 01 42.75
Scale
As indicated
CANOPY - SECTION SCALE: 1 : 20
06
A-6500 © 2016 Gensler
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7 GL04
DLM FACADE
MT06
MT06
MT06
OWNER VIF 12
SEE ELEVATION
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
12 12
150
150
12
12
150
12
12
MASTER ARCHITECT
150
150
150
150
GL04
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
12
12
12
12
12
ARCHITECT OF RECORD
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
MT06
MT06
02 ________ ________ A-6600
INTERIOR DESIGNER
A.3
A.3
A.3
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
A.3
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100 MT06
12
13
INTERIOR LIGHTING CONSULTANT
150
150
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944 MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
150
14
12
MT06
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
150
GL04
STRUCTURAL ENGINEER
2
SCALE: 1 : 4
05
TYPE C1 - VESTIBULE PLAN DETAIL SCALE: 1 : 4
04
COLUMN ENCLOSURE PLAN DETAIL @ VESTIBULE
03
SCALE: 1 : 4
PLAN DETAIL @ DISPLAY WINDOW
01
SCALE: 1 : 4
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
2
HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940 FACADE CONSULTANT
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
Refer to Arch. Dwgs. for Waterproofing Details
MT05
MT06
Date 1
MT-05
Structural Thermal Break Coord. w/ Struct. Dwgs.
Description
10/31/2016 ISSUE FOR 100% DD
Interior Finish
GL-04
Seal/Signature
W-C1 Section @ Head SCALE: 1 : 5
6 MT06
Project Name
137
HOLT RENFREW OGILVY
GL-04.
Project Number
Stainless Steel Shoe
150
Callout of Callout (2) of FACADE PLAN - LEVEL 01
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
06.9964.000
MT09
SLOPE 2% TO DRAIN
Description
LEVEL 01 42.75
ENTRY AND DISPLAY WINDOW AREA DETAILS
Scale
As indicated
W-C1 Section @ Sill SCALE: 1 : 5
7
COLUMN ENCLOSURE TYPICAL SECTION SCALE: 1 : 4
02
A-6600 © 2016 Gensler
SHEET NOTES 01 02 03
N.I.C
04 05 06 07 08
V.I.F. W/ EXISTING CANOPY STRUCTURE
2438
03
02
09
EXISTING CANOPY STRUCTURE/SUPPORT NEW CANOPY DRAINAGE. EXISTING STOREFRONT TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. NEW METAL FINISH CLAD ON EXISTING CANOPY STRUCTURES. NEW LIGHT FIXTURE AS PER SCHEDULE. NEW EXTERIOR HEATER AS PER SCHEDULE. LED LIGHT ILLUMINATION AT MTL. REVEAL. EXISTING SOFFIT TO BE PROTECTED DURING ALL PHASES OF CONSTRUCTION. EXISTING CANOPY DRAINAGE PIPES TO BE PROTECTED AND REUSED.
Holt Renfrew | Ogilvy 1307 Rue Sainte-Catherine Ouest Montréal, (Québec) Canada H3G 1P7
DLM FACADE OWNER
60 Bloor Street West Suite 300 Toronto, (Ontario) Canada M4W 3B8 Telephone 514.842.7711
04
MASTER ARCHITECT 01
1700 Broadway Suite 400 New York, NY USA 10019 Telephone 212.492.1400
ARCHITECT OF RECORD 11978
780 Avenue Brewster 4e Étage Montréal, (Québec) Canada H4C 2K1 Telephone 514.932.5101
V.I.F. W/ EXISTING CANOPY STURCTURE
NOTE: EXISTING CANOPY FINISHES TO BE REMOVED. EXISTING CANOPY STRUCTURES TO BE REPAIRED & PREPARED TO RECEIVE NEW METAL FINISH AS REQD. PRIOR TO CLAD/INSTALLATION.
OGILVY BLDG. CANOPY - PLAN
INTERIOR DESIGNER
1
SCALE: 1 : 30
435 Hudson Street 8th Floor New York, NY USA 10014 Telephone 212.366.1611
EXTERIOR LIGHTING CONSULTANT
247 West 37th Street Suite 1502 New York, NY USA 10018 Telephone 212.382.2100
381 V.I.F
04
EQ. B
EQ. B
1000 TYP. EQ. A
335 West 38th Street New York, NY USA 10018 Telephone 212.967.5944
750 TYP.
05
03
MECHANICAL, ELECTRICAL, PLUMBING & FIRE PROTECTION ENGINEERS
9825 Rue Verville Montréal, (Québec) Canada H3L 3E1 Telephone 514.383.3747
EQ. C
06
EQ. C
INTERIOR LIGHTING CONSULTANT
2057
V.I.F. W/ EXISTING CANOPY STRUCTURE
2438
N.I.C
10000
EQ. A
STRUCTURAL ENGINEER
12046 V.I.F. W/ EXISTING CANOPY STRUCTURE
OGILVY BLDG. CANOPY - RCP PLAN
1200 Avenue McGill College Bureau 1200 Montréal, (Québec) Canada H3B 4G7 Telephone 514.878.3021
2
SCALE: 1 : 30
VERTICAL TRANSPORTATION ENGINEERS
1410 Rue Stanley Bureau 604 Montréal, (Québec) Canada H4C 2K1 Telephone 514.284.3119
6
7
8 HISTORIC PRESERVATION CONSULTANT
1435 Rue Saint-Alexandre Bureau 1000 Montréal, (Québec) Canada H3A 2G4 Telephone 514.393.9490 CODE CONSULTANT
460 Rue Saint-Catherine Ouest Bureau 730 Montréal, (Québec) Canada H3B 1A7 Telephone 514.861.1940
N.I.C N.I.C
N.I.C
03
FACADE CONSULTANT 03 01
01
03
440 Park Avenue South, 15th Floor New York, NY 10016 Telephone 212.652.2966
03
02
2057 1236
06
06
Date
08
484
38 331 115
1
2438 854
2
Description
08/05/2016 ISSUE FOR PRICING - PROGRESS DD SET 10/31/2016 ISSUE FOR 100% DD
V.I.F. W/ EXISTING CANOPY STRUCTURE
3292 V.I.F. W/ EXISTING CANOPY STRUCTURE
OGILVY BLDG. CANOPY - SECTION
04
08
381
03
5
VARIES BY LOCATION
VARIES BY LOCATION
3106
2438
06
OGILVY BLDG. CANOPY - SIDE ELEVATION SCALE: 1 : 30
4
VARIES BY LOCATION
08
2057
227
115
06
2862
04
3106
07
SCALE: 1 : 30
484
227
115
484
09
07
04
38 331
07
227
02
38 331
01
OGILVY BLDG. CANOPY - ELEVATION SCALE: 1 : 30
03
03
3
Seal/Signature
Project Name
HOLT RENFREW OGILVY Project Number
06.9964.000 Description
OGILVY CANOPY
Scale
1 : 30
A-6700 © 2016 Gensler