handover document

Page 1




Mr Philip Keefe 17 Summit Way Crystal Palace London SE19 2PU Doc ref SolPV HO

Version 1

Page 2 of 3


Mr Philip Keefe 17 Summit Way Crystal Palace London SE19 2PU

Doc ref SolPV HO

Version 1

Page 1 of 3

System Schematic and technical information System specification System components PV modules

8 of JA Solar JAM60-250J5 modules Serial numbers 1110M603S001601027859, 1110M603S001601028034 1110M603S001601027927, 1110M603S001601027874 1110M603S001601027864, 1110M603S001601028047 1110M603S001601028618, 1110M603S001601028868

Inverter

SunnyBoy SB1700 serial no 2001962575

Generation meters

Landys and Gyr A201146501

Output of System Azimuth of system Pitch of system SAP predicted annual yield

2.0 kwp south east facing 20 degrees 1643 kwh per annum

Your system has been installed by

Complete Plumbing Clean Energy 16-18 Paxton Place SE27 9SS Tel 0208 670 9538 Email info@cphsi.com

In accordance with the REAL assurance code and MCS standard document MIS 3002. Installation Date

25.11.2011

The performance of solar PV systems is impossible to predict with certainty due to the variability in the amount of solar radiation (sunlight) from location to location and from year to year. This estimate is based upon the Government's standard assessment procedure for energy rating of buildings (SAP) and is given as guidance only. It should not be considered as a guarantee of performance."


Mr Philip Keefe 17 Summit Way Crystal Palace London SE19 2PU

Doc ref SolPV HO

Version 1

Page 3 of 3

Warranty Data Solar modules

JA Solar JAM60-245-J5 x8

Output guarantee to 90% pmpp min Output guarantee to 80% Pmpp min Workmanship Product standards inverter warrantee inverter warrantee Supplier

90% 12 years 80% 25 years 5 years IEC61215 SunnyBoy SB1700 5 years Zenex Solar

Inverter Manufacturer

SMA Technology Sonnenallee 1 34266 Niestetal Germany Tel. +49 561 9522 0 Fax +49 561 9522 100 www.SMA.de info@SMA.de

Module Manufacturer

Your system has been installed by

JA solar Technology Ltd JA Solar Technology Co Ltd E6-E8 Plot Minhang Export Processing Zone Fengxian Shanghai 201401 China Tel +86(21)3718 1000 Email: Service@jasolar.com www.jasolar.com

Complete Plumbing Clean Energy 16-18 Paxton Place SE27 9SS Tel 0208 670 9538 Email info@cphsi.com

In accordance with the REAL assurance code and MCS standard document MIS 3002.


PV Incentive Comparison Calculator Mr P Keefe 17 Summit Way London SE19 2PU Renewable Technology

Photvoltaic

output rating

2

deemed output kw hours per year

1643.2

rate of tarrif or incentive

0.43

lifetime of tarrif

25

value of genration tarrif per year (41.3p per kw generated)

706.576

value of export taffif (50% of total generated x 3p)

24.648

units saved per year ( 50% of total generated)

821.6

unit cost of input fuel

0.12

value of saving at fuel cost 12p electric 4p gas

98.592

gain per watt output

0.505

Total financial gain from technology per year

829.816

Cost of supply and installation life time of tarrif

25

cost per year

0

cost per watt output

0

gain per watt output

0.505

nett gain

0.505

nett gain one year

ÂŁ829.82

nett gain life time of tarrif

ÂŁ20,745.40

Tarriffs are set to deliver an approximate rate of return of 5-8% for well sited installations As the tarrifs are linked to inflation in nominal terms the rate of return could therefore be considered to be approximatly 7-10% In the 2009 pre budget report the chancellor confirmed that households who use renewable technology to generate electricity mainly for own use will not be subject to income tax on feed in tarrifs. Department of Energy and Climate Change February 2010

The performance of solar PV systems is impossible to predict with certainty due to the variability in the amount of solar radiation (sunlight) from location to location and from year to year. This estimate is based upon the Government's standard assessment procedure for energy rating of buildings (SAP) and is given as guidance only. It should not be considered as a guarantee of performance."


PV Incentive Comparison Calculator Mr P Keefe 17 Summit Way London SE19 2PU

SAP Calculation Appendix M

Electricity Produced by PV Modules = 0.8xkwpxSxZpv S Annual solar irradiation from Table H2 Zpv Overshading Factor from Table H3

Table H2 Orientation of collector Horizontal

South

SE/SW

E/W

30 deg

1073

1027

913

785

730

45 deg

1054

997

854

686

640

60 deg

989

927

776

597

500

vertical

746

705

582

440

371

NE/NW

North

Overshading Factor Overshading Heavy Significant Modest None or very little

Energy and Climate Change

percent of sky blocked by obstacles greater 80% 60-80% 20-60% less than 20%

SAP Calculation KWP of array S solar irradiation Shading factor Annual SAP estimated output

Overshading Factor 0.5 0.65 0.8 1.0

0.8*kwp*S*Zs 2 1027 1 1643.2

The performance of solar PV systems is impossible to predict with certainty due to the variability in the amount of solar radiation (sunlight) from location to location and from year to year. This estimate is based upon the Government's standard assessment procedure for energy rating of buildings (SAP) and is given as guidance only. It should not be considered as a guarantee of performance."



PVSYST V5.52

complete plumbing clean energy

21/11/11 Page 1/4

JAM60-250-J5x8 SB1700 i2.0kwp shading sim 1419kwh

Grid-Connected System: Simulation parameters Project :

Philip Keefe

Geographical Site

London Latitude Legal Time Albedo

Situation Time defined as

Country 51.4°N Time zone UT+0 0.20

Longitude Altitude

Meteo data :

London, Synthetic Hourly data

Simulation variant :

JA Solar 250 x 8 SB1700 inverter shading 1419 kwh Simulation date

United Kingdom 0.0°E 5m

07/11/11 12h21

Simulation parameters Tilt

Collector Plane Orientation

30°

Azimuth

-55°

Free Horizon

Horizon

Linear shadings

Near Shadings PV Array Characteristics PV module

Si-mono

Number of PV modules Total number of PV modules Array global power Array operating characteristics (50°C) Total area Inverter Characteristics

Model Manufacturer In series Nb. modules Nominal (STC) U mpp Module area

JAM6-60-250 JA Solar 8 modules In parallel 8 Unit Nom. Power At operating cond. 2000 Wp 224 V I mpp Cell area 13.1 m²

1 strings 250 Wp 1806 Wp (50°C) 8.1 A 11.4 m²

Model Manufacturer Operating Voltage

Sunny Boy SB 1700 SMA 139-320 V Unit Nom. Power

1.55 kW AC

PV Array loss factors Thermal Loss factor Uc (const) 20.0 W/m²K => Nominal Oper. Coll. Temp. (G=800 W/m², Tamb=20°C, Wind=1 m/s.) Wiring Ohmic Loss Global array res. Module Quality Loss Module Mismatch Losses Incidence effect, ASHRAE parametrization IAM =

User's needs :

Unlimited load (grid)

464 mOhm

1 - bo (1/cos i - 1)

Uv (wind) NOCT Loss Fraction Loss Fraction Loss Fraction bo Parameter

0.0 W/m²K / m/s 56 °C 1.5 % at STC 1.5 % 2.0 % at MPP 0.05


PVSYST V5.52

complete plumbing clean energy

21/11/11 Page 2/4

JAM60-250-J5x8 SB1700 i2.0kwp shading sim 1419kwh

Grid-Connected System: Near shading definition Project :

Philip Keefe

Simulation variant :

JA Solar 250 x 8 SB1700 inverter shading 1419 kwh System type Linear shadings tilt Model Nb. of modules Model Unlimited load (grid)

Main system parameters Near Shadings PV Field Orientation PV modules PV Array Inverter User's needs

Grid-Connected 30째 JAM6-60-250 8 Sunny Boy SB 1700

azimuth Pnom Pnom total Pnom

-55째 250 Wp 2000 Wp 1550 W ac

Perspective of the PV-field and surrounding shading scene Zenith

East

West

South

Iso-shadings diagram Philip Keefe: Philip Keefe 17 Summit Way SW19 Beam shading factor (linear calculation) : Iso-shadings curves

90

Shading loss: 1 % Shading loss: 5 % Shading loss: 10 % Shading loss: 20 % Shading loss: 40 %

Attenuation for diffuse: 0.892 and albedo: 0.842

1: 22 june 2: 22 may - 23 july 3: 20 apr - 23 aug 4: 20 mar - 23 sep 5: 21 feb - 23 oct 6: 19 jan - 22 nov 7: 22 december

75

11h

60

12h 1 2

13h 14h

Sun height [째]

10h 3

15h

9h 45

30

16h

4

8h

17h

7h

5

6h

18h

6 7

15

19h

5h Behind the plane

Behind the plane 0 -120

-90

-60

-30

0 Azimuth [째]

30

60

90

120


PVSYST V5.52

complete plumbing clean energy

21/11/11 Page 3/4

JAM60-250-J5x8 SB1700 i2.0kwp shading sim 1419kwh

Grid-Connected System: Main results Project :

Philip Keefe

Simulation variant :

JA Solar 250 x 8 SB1700 inverter shading 1419 kwh System type Linear shadings tilt Model Nb. of modules Model Unlimited load (grid)

Main system parameters Near Shadings PV Field Orientation PV modules PV Array Inverter User's needs Main simulation results System Production

Produced Energy Performance Ratio PR

Grid-Connected 30° JAM6-60-250 8 Sunny Boy SB 1700

1419 kWh/year 70.9 %

azimuth Pnom Pnom total Pnom

Specific prod.

Normalized productions (per installed kWp): Nominal power 2000 Wp

-55° 250 Wp 2000 Wp 1550 W ac

709 kWh/kWp/year

Performance Ratio PR

6

0.8 Lc : Collection Loss (PV-array losses) 0.6 kWh/kWp/day Ls : System Loss (inverter, ...) 0.2 kWh/kWp/day Yf : Produced useful energy (inverter output) 1.94 kWh/kWp/day

PR : Performance Ratio (Yf / Yr) : 0.709

0.7

5

Performance Ratio PR

Normalized Energy [kWh/kWp/day]

0.6 4

3

0.5

0.4

0.3

2 0.2 1 0.1

0

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

0.0

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

JA Solar 250 x 8 SB1700 inverter shading 1419 kwh Balances and main results GlobHor

T Amb

GlobInc

GlobEff

EArray

E_Grid

EffArrR

EffSysR

kWh/m²

°C

kWh/m²

kWh/m²

kWh

kWh

%

%

January

20.0

5.70

25.8

23.1

42.0

36.0

12.44

10.66

February

34.0

5.50

39.7

35.6

65.3

58.0

12.59

11.18

March

70.0

6.80

77.0

69.5

127.2

115.3

12.62

11.44

April

103.0

8.30

107.1

95.2

172.6

157.5

12.33

11.24

May

138.0

11.50

136.5

118.5

210.8

192.6

11.81

10.78

June

146.0

14.70

140.6

121.7

213.6

195.0

11.61

10.60

July

142.0

17.10

137.9

119.5

206.5

188.4

11.45

10.44

August

124.0

17.10

125.9

110.8

191.4

174.7

11.63

10.61

September

88.0

15.20

97.0

87.5

153.8

140.4

12.12

11.06

October

52.0

11.60

60.4

54.7

98.1

88.4

12.41

11.19

November

26.0

8.20

33.6

30.3

54.4

47.7

12.37

10.85

December

15.0

6.90

18.8

16.7

29.6

24.8

12.02

10.06

Year

958.0

10.75

1000.3

883.0

1565.3

1418.6

11.96

10.84

Legends:

GlobHor

Horizontal global irradiation

EArray

Effective energy at the output of the array

T Amb

Ambient Temperature

E_Grid

Energy injected into grid

GlobInc

Global incident in coll. plane

EffArrR

Effic. Eout array / rough area

GlobEff

Effective Global, corr. for IAM and shadings

EffSysR

Effic. Eout system / rough area

Nov

Dec


PVSYST V5.52

complete plumbing clean energy

21/11/11 Page 4/4

JAM60-250-J5x8 SB1700 i2.0kwp shading sim 1419kwh

Grid-Connected System: Loss diagram Project :

Philip Keefe

Simulation variant :

JA Solar 250 x 8 SB1700 inverter shading 1419 kwh

Main system parameters Near Shadings PV Field Orientation PV modules PV Array Inverter User's needs

System type Linear shadings tilt Model Nb. of modules Model Unlimited load (grid)

Grid-Connected 30° JAM6-60-250 8 Sunny Boy SB 1700

azimuth Pnom Pnom total Pnom

-55° 250 Wp 2000 Wp 1550 W ac

Loss diagram over the whole year

958 kWh/m² +4.4% -9.0% -3.0% 883 kWh/m² * 13 m² coll.

Horizontal global irradiation Global incident in coll. plane Near Shadings, "linear" IAM factor on global Effective irradiance on collectors

efficiency at STC = 15.54%

PV conversion

1794 kWh

Array nominal energy (at STC effic.) -6.6% -2.4%

PV loss due to irradiance level PV loss due to temperature

-1.6%

Module quality loss

-2.1%

Module array mismatch loss

-0.6%

Ohmic wiring loss Array virtual energy at MPP

-9.4%

Inverter Loss during operation (efficiency)

1565 kWh

0.0% 0.0% 0.0% 0.0% 1419 kWh

Inverter Loss over nominal inv. power Inverter Loss due to power threshold Inverter Loss over nominal inv. voltage Inverter Loss due to voltage threshold Available Energy at Inverter Output

1419 kWh

Energy injected into grid


PVSYST V5.52

complete plumbing clean energy

02/11/11

16-18 Paxton place - SE27 9SS-London - United kingdom Mr Philip Keefe shading tables 0.892

Near Shadings definition Philip Keefe 17 Summit Way SW19

Near Shadings : Geographical Site

London

Country

(Multi) Rectangular field no 1 Tilt 30° Diffuse Factor 0.892

Defined active PV fields Orientation: Constant shading factors

area Azimuth Albedo Factor

United Kingdom 13 m² -55° 0.842

Shading factor table (linear), for the beam component Azimuth -180°

-160°

-140°

-120°

-100°

-80°

-60°

-40°

-20°

20°

40°

60°

80°

100°

120°

140°

160°

180°

Height 90°

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

80°

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

70°

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

0.999

0.992

0.990

0.993

0.998

1.000

60°

0.999

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

0.999

0.975

0.962

0.965

0.978

0.991

0.999

50°

0.999

0.994

0.998

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

1.000

0.976

0.922

0.893

0.915

0.957

0.988

0.999

40°

0.968

0.726

0.461

0.638

0.985

1.000

1.000

1.000

1.000

1.000

1.000

1.000

0.930

0.795

0.670

0.798

0.947

0.988

0.968

30°

0.110

0.296

0.247

0.197

0.269

1.000

1.000

1.000

1.000

1.000

1.000

1.000

0.813

0.514

0.618

0.680

0.936

0.968

0.110

20°

0.006

0.296

0.247

0.196

0.000

1.000

1.000

1.000

1.000

1.000

1.000

0.998

0.662

0.232

0.566

Behind

Behind

0.949

0.006

10°

Behind

0.296

0.247

0.196

0.000

1.000

1.000

1.000

1.000

1.000

1.000

0.981

0.511

Behind

Behind

Behind

Behind

Behind

Behind

Behind

0.296

0.247

0.196

0.000

1.000

1.000

1.000

1.000

1.000

1.000

0.965

Behind

Behind

Behind

Behind

Behind

Behind

Behind

Shading factor for diffuse: 0.892 and for albedo: 0.842





Datasheet SMA Sunny Boy inverter SB1200

1/2


Datasheet SMA Sunny Boy inverter SB1200

. r 4 k

2/2




Document Ref: MCSR 10.07 Microgeneration Certification Scheme Requirements COMPLETE PLUMBING & HEATING SERVICES LTD

Version: 1.0 Page 1 of 1

PV Array Test Report — D.0 Circuits Contractors name and address Complete plumbing clean energy 16-18 Paxton place SE27 9SS

Report reference No: Installation 17 Summit Way SE19 2PU

Test Date Description of work under test Solar pv TBCkwp

String Array

Signature Test Instrument(s) Clamp meter 10071345

1 JA solar JAM-60-250J5 8 37.82

Module Quantity

Array parameters

Voc(stc)

8.68 n/a n/a n/a n/a 4mm

I sc( stc)

Protective Device

Type Rating

(A)

D.C. Rating Capacity Wiring

String test Test Method: Annex-2

(V) (KA)

Type Phase Earth Voc Isc

(mm 2) (mm 2) (V)

287VDC 0.8 amps

(A)

150 watts

Sun Polarity check Earth continuity (where fitted) Connected to inverter (serial No.) Array insulation resistance Test Voltage Ref IEC 60 - de Easy Rcg No -.3Q7210 Test method: Annex-1 Pos - Earth (Nu) Neg - Earth (MO) Comments Tests carried oout by Nicholas I Cotton 26.11.2011

CPCE MCSR 10.07 Page 1 of 1

2

Yes 2001962575 1St ,uly

2000

<200mohms <200mohms <200mohms

Photovoltaic installation inspection and testing


MCS Installer Certificate No. MCS-00173460-X INSTALLER DETAILS MCS Certificated Installation Company Name: Complete Plumbing Clean Energy Ltd MCS Certificated Installation Company Number:

NAP 15335

MCS Certificated Installer Name: Nicholas Cotton

PRODUCT DETAILS MCS Certificated Product Name:

JAM6-60 series

MCS Certificated Product Manufacturer:

Shanghai JA Solar Tech Co Ltd. E6, E8 Plot, Shanghai Fengxian Area Shanghai, 201401, PRC.

MCS Certificated Product Number:

BABT 8515-01

Technology Type:

SOLAR PHOTOVOLTAIC

Estimated Annual Generation (kWh):

1643.00

Declared Net Capacity (kW):

2.00

INSTALLATION ADDRESS DETAILS Address:

17 SUMMIT WAY SE19 2PU

Supply MPAN:

1900047088788

Installation Type:

Non-Standalone

Commissioning Date:

24/11/2011

GENERATION METER DETAILS Generation Meter Serial Number (MSN): Generation Meter Reading: 0.00 (at commissioning date)

A201146501



NAPIT - Work Notification Details

1 of 1

NAPIT Administration

http://www.napitonline.com/ShowInstallation.asp?InstallationID=659041

Work Notification Details - Complete Plumbing Clean Energy Ltd (15335) - Work ID 659041 Click on an individual job to amend the record. All entries are saved automatically on to the database. Please ensure sections 1 and 2 are complete to finalise this work notification. Once both sections are complete and all details of the works have been recorded, click return to exit.

Section 1: Works date and Site Details Work Notification Complete. Local Authority will be notified on Saturday Go Back Member Menu Log Off

Work Notification ID : 659041

Installation Ref : CN50019

Installation Date : 24/11/2011 Installation Contact : Mr Philip Keefe Installation Telephone : 02086533045 Installation Address : 17 Summit Way

Contact Us

Dispatch Contact : Dispatch Address : 17 Summit Way

LONDON

LONDON

SE19 2PU SE19 2PU Operatives Involved : Nicholas Cotton, Complete Plumbing Clean Energy Ltd

Section 2: Work Activity Details

Work Type

Work

Location

Quantity

Status

Renewables Installed photovoltaics (PV modules)

House Dwelling

1

Notifiable to LA

Renewables Installed an invertor for microgeneration equipment

House Dwelling

1

Notifiable to LA

Copyright Š 2006 Borough IT Ltd . All rights reserved.

Legal | Privacy | Contact

24/11/2011 14:33


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.