Potterton Gold Combi HE A

A compact model with flexible siting options, the Potterton Gold Combi HE A also lives up to Potterton’s trademark reliability. With a two year warranty and a host of useful features, this is one boiler that’s worth its weight in gold.

.H\ IHDWXUHV DQG EHQHILWV 24kW, 28kW and 33kW wall-mounted models

Filling loop included

A 2 year parts and labour product warranty

Fitted with an integral clock

Features the very latest stainless steel heat exchanger technology

24kW voted a ‘Best Buy’ in Which? Magazine report (September 2006 & 2007) for efficiency, ease of use and durability

Integral frost protection Intelligent control system that automatically adjusts the heat output to match demand

Suitable for use with the Multifit GasSaver - which can give annual DHW gas savings of upto 37%

Compact size for ease of installation Don’t forget to register your boiler so we can activate the 2 year warranty.

2 )XOO\ PRGXODWLQJ

)LWWHG FORFN

\HDU ZDUUDQW\

8OWUD ORZ 12[ HPLVVLRQV &ODVV WKH EHVW

&DQ EH VLWXDWHG LQ DQ XQYHQWLODWHG FXSERDUG

6('%8. %DQG $


Technical Information - 24, 28 & 33 HE A 5mm min

5mm min 450mm

200mm min

780mm

200mm min

NB. Flue is offset to the right. 5mm min in operation 450mm for servicing

3° (1 in 20) or 1.5° providing flue has been adequately clamped as per installation instructions

345mm

Gold Combi HE A Sales Code (Boiler only) Sales Code (Std Flue) Sales Code (Boiler with flue) Controls Concealed User Controls Operating mode selector switch with reset User adjustable DHW temperature User adjustable CH temperature LCD Operating Status Display LED Operating Status Display Integral 24hr Electro-Mechanical Timer Integral 7 day Electronic Timer Single Channel Wireless Programmable Room Thermostat Gas Gas (Natural Gas/LPG) Inlet Supply Pressure Maximum Gas Rate Central Heating Input (max) Central Heating Output - Condensing (max) Central Heating Output - Non condensing (max) Domestic Hot Water Input (max) Seasonal Efficiency SEDBUK Rating NOx Class NOx Levels EcoHomes Electrical Electrical Supply Permanent Live Required Power Consumtion External Fuse Rating Integral 'Boiler Only' Frost Thermostat Mechanical Wall Mounting Jig Isolating valves Gas Supply Connection Central Heating Connections Domestic Hot Water Connections Condensate Drain Connection Safety Discharge Connection Filling Loop Kit Hydraulic Domestic Hot Water Output (Raised 35o C) (max) Domestic Hot Water Operating Flow Rate (min) Domestic Hot Water Operating Pressure (min) Domestic Hot Water System Pressure (max) Safety Discharge Discharge Pressure Integral Automatic Bypass Integral Expansion Vessel Capacity CH System Capacity (max) Compartment Ventilation Required 24hr Pump Exercise Pump Overrun Concentric Flue Systems Concentric Flue Diameters Concentric Flue Length Max. Equivalent Vertical Length (Ø 60/100) Max. Equivalent Vertical Length (Ø 80/125) Max. Equivalent Horizontal Length (Ø 60/100) Max. Equivalent Horizontal Length (Ø 80/125) Twin Flue System Twin Pipe Flue Diameter Max. Equivalent Vertical Length Max. Equivalent Horizontal Length Plume Displacement Kit Max. Equivalent Vertical Length Weights Gross Packaged Boiler Weight Packaged Boiler Dimensions (LxWxD)

Units

mbar m3/hr kW kW kW kW % Band mg/kWhr Credits Volts/Hz watts amps

mm mm mm mm mm l/min l/min bar bar bar litres litres

24kW 5115896 5118489 5115897

28kW 5116207 5118489 5116208

33kW 5116209 5118489 5116210

Yes Yes Yes Yes Yes Yes Yes Optional Optional

Yes Yes Yes Yes Yes Yes Yes Optional Optional

Yes Yes Yes Yes Yes Yes Yes Optional Optional

NG 20 2.61 22.7 21 20 27.4 91.1 A 5 22.3 3

NG 20 3.06 27.4 25.9 24 32.1 91.1 A 5 26 3

NG 20 3.59 32.1 30.3 28 37.7 91.1 A 5 21.8 3

230/50 Yes 155 3 Yes

230/50 Yes 155 3 Yes

230/50 Yes 160 3 Yes

Yes Yes 22 22 15 21.5 15 Yes

Yes Yes 22 22 15 21.5 15 Yes

Yes Yes 22 22 15 21.5 15 Yes

9.8 2 0.15 8 3 Yes 8 125 No Yes Yes

11.5 2 0.15 8 3 Yes 8 125 No Yes Yes

13.5 2 0.15 10 3 Yes 10 155 No Yes Yes

mm mm m m m m

685 10 20 10 20

60/100 and 80/125 685 685 10 10 20 20 10 10 20 20

mm m m

80/80 15 15

80/80 15 15

80/80 15 15

m

13

13

8

kg mm

48.6

48.6 51 964 x 540 x 403

)OXH 2SWLRQV The standard flue is suitable only for horizontal termination applications. Maximum permissible equivalent flue lengths are:

Type:

Horizontal Concentric Vertical Concentric Horizontal/Vertical Twin Pipe Boiler Only *Depending on flue system used. Std. Flue

10/20* metres 10/20* metres 15 metres

Boiler with Std.be Flue Any additional ‘in line’ bends in the flue system must taken into consideration.

Gold CombiTheir 24 HE Plus B5115896 equivalent lengths are:

B5118489

Concentric Pipes:

135° bend B5118489 93° bend 135° bend 90° bend B5118489

Gold Combi 28 HE Plus

B5116207

Twin Flue Pipe:

Gold Combi 33 HE Plus

B5116209

The Potterton Gold Combi HE A can be fitted with the following flue systems: Horizontal Concentric

B5115897 0.5 metres

B5116208 1.0 metres 0.25 metres 0.50 metres B5116210

The elbow is now supplied with the flue system (not the appliance) and is not included in any equivalent length calculations. The Multifit flue illustrations show examples of permissible flue lengths. Instructions for guidance and fitting are included in each kit, where appropriate.

Flue System A Flue System G

Vertical Concentric

Flue System A Flue System G

Twin Pipe

Flue System N

Plume Displacement Kit

Flue System K


Vertical Concentric Flues 60/100mm - Flue System A

Horizontal Concentric Flues 60/100mm - Flue System A Item Description (MULTIFIT) Flue System A

Specification

KEY & OD Dimensions

Multifit Sales Code

Item Description (MULTIFIT) Flue System A

Standard Horizontal Flue inc Elbow

685mm

Specification

Key & OD Dimensions

Multifit Sales Code 5118576

60/100mm

5118489

Vertical Flue Terminal

100mm

Standard Horizontal Telescopic Flue 315-500mm inc Elbow

60/100mm

5118069

Roof Cover Plate

125mm

246143

Telescopic Internal Flue Kit

Flue Extension

1000mm

100mm

5111074 5111075

100mm

5119654

Flue Bend

93 degree

100mm

Flue Extension

1000mm

100mm

5111074

Flue Bend (Pair)

135 degree

100mm

5111085

Flue Bend (Pair)

135 degree

100mm

5111085

Flue Bend

135 degree

100mm

5111076

Flue Bend

135 degree

100mm

5111076

Pipe Support

Painted white

Flue Bend

93 degree

100mm

5111075

Pitched Roof Flashing

25 / 50 degree

125mm

5122151

Flat Roof Flashing

125mm

246144

Flue Wall Liner

100mm

5111067

Flue Terminal Deflector

60mm

5111068

100mm

5111080

Pipe Support

Painted white

5111080

Horizontal Concentric Flues 80/125mm - Flue System G Item Description (MULTIFIT) Flue System G

Specification

Horizontal Flue incl boiler & terminal adaptors

Key & OD Dimensions

Multifit Sales Code

125mm

5118580

Flue Extension

1000mm

125mm

5118584

Flue Bend

91.5 degree

125mm

5118588

Flue Bend (pair)

135 degree

125mm

5118597

Pipe Support

For use with 125mm Flue Pipes

125mm

5118610

Vertical Concentric Flues 80/125mm - Flue System G Item Description (MULTIFIT) Flue System G

Specification

Key & OD Dimensions 125mm

5111078

Flue Extension

1000mm

125mm

5118584

Flue Bend

91.5 degree

125mm

5118588

Flue Bend (Pair)

135 degree

125mm

5118597

Vertical Flue Terminal

Multifit Sales Code

Roof Cover Plate

125mm

246143

Flue Vertical Adaptor

100/125mm

5111070

Pitched Roof Flashing

25 / 50 degree

Flat Roof Flashing Pipe Support

For use with 125mm Flue Pipes

125mm

5122151

125mm

246144

125mm

5118610

Twin Pipe Flues 80/80mm - Flue System N Item Description (MULTIFIT) Flue System N

Specification

Vertical Flue Terminal

Key & OD Dimensions

Multifit Sales Code

125mm

5111078

Twin Pipe Extension (Pair inc Brackets)

1000mm

80mm

5111087

Twin Pipe Flue Bend (Pair)

90 degree

80mm

5111072

Twin Pipe Flue Bend (2 Pair)

135 degree

80mm

5111086

125mm

246143

80mm

5120172

Item Description (MULTIFIT) Flue System K

80mm

5111081

80/125mm

5111084

Plume Displacement Kit inc Elbow & clips

Roof Cover Plate Twin Pipe Flue Horizontal Terminal Kit (Pair) Twin Pipe Support (Pair)

Painted White

Twin to Concentric Adaptor 80/80 - 80/125

Plume Displacement 60/100mm Concentric to 60mm PDK - Flue System K Specification

Key & OD Dimensions

Multifit Sales Code

100mm

5118638

1000mm

60mm

5121368

125mm

5122151

Plume Displacement Kit Extension inc clip

Flat Roof Flashing

125mm

246144

Plume Displacement Kit Bend

93 degree

60mm

5121369

Twin Pipe Flue Adaptor (Boiler)

80mm

720089801

Plume Displacement Kit Bend (Pair)

135 degree

60mm

5121370

Pitched Roof Flashing

25 / 50 degree

Optional Accessories Item Description (MULTIFIT)

Specification

Key & OD Dimensions

Multifit Sales Code

Stand Off Kit

Combi and System Boilers only

40mm

5117035

Integral 24 hr Electro-mechanical Timer

Combi Boilers only

Image 1

247206

Integral 7 Day Electronic Timer

Combi Boilers only

Image 2

247207

Wireless Electro Mechanical Timer Room Thermostat

Combi Boilers only

Image 3

5117392

GasSaver

Gold only

Image 5

Expansion Valve Kit

GasSaver only

720055901

Stand Off kit

GasSaver only

720079701

Wireless Digital Timer Room Thermostat

Contacts: General Enquiries Tel:

Image 4 720056901

0844 8711 560 1.

For further information visit: www.pottertongold.co.uk Please note - calls to the contact centre may be recorded or monitored.

2.

3.

4.

5.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.