Combi
boiler
Potterton Gold Combi HE
Potterton Gold Combi HE A
A compact model with flexible siting options, the Potterton Gold Combi HE A also lives up to Potterton’s trademark reliability. With a two year warranty and a host of useful features, this is one boiler that’s worth its weight in gold.
.H\ IHDWXUHV DQG EHQHILWV 24kW, 28kW and 33kW wall-mounted models
Filling loop included
A 2 year parts and labour product warranty
Fitted with an integral clock
Features the very latest stainless steel heat exchanger technology
24kW voted a ‘Best Buy’ in Which? Magazine report (September 2006 & 2007) for efficiency, ease of use and durability
Integral frost protection Intelligent control system that automatically adjusts the heat output to match demand
Suitable for use with the Multifit GasSaver - which can give annual DHW gas savings of upto 37%
Compact size for ease of installation Don’t forget to register your boiler so we can activate the 2 year warranty.
2 )XOO\ PRGXODWLQJ
)LWWHG FORFN
\HDU ZDUUDQW\
8OWUD ORZ 12[ HPLVVLRQV &ODVV WKH EHVW
&DQ EH VLWXDWHG LQ DQ XQYHQWLODWHG FXSERDUG
6('%8. %DQG $
Technical Information - 24, 28 & 33 HE A 5mm min
5mm min 450mm
200mm min
780mm
200mm min
NB. Flue is offset to the right. 5mm min in operation 450mm for servicing
3° (1 in 20) or 1.5° providing flue has been adequately clamped as per installation instructions
345mm
Gold Combi HE A Sales Code (Boiler only) Sales Code (Std Flue) Sales Code (Boiler with flue) Controls Concealed User Controls Operating mode selector switch with reset User adjustable DHW temperature User adjustable CH temperature LCD Operating Status Display LED Operating Status Display Integral 24hr Electro-Mechanical Timer Integral 7 day Electronic Timer Single Channel Wireless Programmable Room Thermostat Gas Gas (Natural Gas/LPG) Inlet Supply Pressure Maximum Gas Rate Central Heating Input (max) Central Heating Output - Condensing (max) Central Heating Output - Non condensing (max) Domestic Hot Water Input (max) Seasonal Efficiency SEDBUK Rating NOx Class NOx Levels EcoHomes Electrical Electrical Supply Permanent Live Required Power Consumtion External Fuse Rating Integral 'Boiler Only' Frost Thermostat Mechanical Wall Mounting Jig Isolating valves Gas Supply Connection Central Heating Connections Domestic Hot Water Connections Condensate Drain Connection Safety Discharge Connection Filling Loop Kit Hydraulic Domestic Hot Water Output (Raised 35o C) (max) Domestic Hot Water Operating Flow Rate (min) Domestic Hot Water Operating Pressure (min) Domestic Hot Water System Pressure (max) Safety Discharge Discharge Pressure Integral Automatic Bypass Integral Expansion Vessel Capacity CH System Capacity (max) Compartment Ventilation Required 24hr Pump Exercise Pump Overrun Concentric Flue Systems Concentric Flue Diameters Concentric Flue Length Max. Equivalent Vertical Length (Ø 60/100) Max. Equivalent Vertical Length (Ø 80/125) Max. Equivalent Horizontal Length (Ø 60/100) Max. Equivalent Horizontal Length (Ø 80/125) Twin Flue System Twin Pipe Flue Diameter Max. Equivalent Vertical Length Max. Equivalent Horizontal Length Plume Displacement Kit Max. Equivalent Vertical Length Weights Gross Packaged Boiler Weight Packaged Boiler Dimensions (LxWxD)
Units
mbar m3/hr kW kW kW kW % Band mg/kWhr Credits Volts/Hz watts amps
mm mm mm mm mm l/min l/min bar bar bar litres litres
24kW 5115896 5118489 5115897
28kW 5116207 5118489 5116208
33kW 5116209 5118489 5116210
Yes Yes Yes Yes Yes Yes Yes Optional Optional
Yes Yes Yes Yes Yes Yes Yes Optional Optional
Yes Yes Yes Yes Yes Yes Yes Optional Optional
NG 20 2.61 22.7 21 20 27.4 91.1 A 5 22.3 3
NG 20 3.06 27.4 25.9 24 32.1 91.1 A 5 26 3
NG 20 3.59 32.1 30.3 28 37.7 91.1 A 5 21.8 3
230/50 Yes 155 3 Yes
230/50 Yes 155 3 Yes
230/50 Yes 160 3 Yes
Yes Yes 22 22 15 21.5 15 Yes
Yes Yes 22 22 15 21.5 15 Yes
Yes Yes 22 22 15 21.5 15 Yes
9.8 2 0.15 8 3 Yes 8 125 No Yes Yes
11.5 2 0.15 8 3 Yes 8 125 No Yes Yes
13.5 2 0.15 10 3 Yes 10 155 No Yes Yes
mm mm m m m m
685 10 20 10 20
60/100 and 80/125 685 685 10 10 20 20 10 10 20 20
mm m m
80/80 15 15
80/80 15 15
80/80 15 15
m
13
13
8
kg mm
48.6
48.6 51 964 x 540 x 403
)OXH 2SWLRQV The standard flue is suitable only for horizontal termination applications. Maximum permissible equivalent flue lengths are:
Type:
Horizontal Concentric Vertical Concentric Horizontal/Vertical Twin Pipe Boiler Only *Depending on flue system used. Std. Flue
10/20* metres 10/20* metres 15 metres
Boiler with Std.be Flue Any additional ‘in line’ bends in the flue system must taken into consideration.
Gold CombiTheir 24 HE Plus B5115896 equivalent lengths are:
B5118489
Concentric Pipes:
135° bend B5118489 93° bend 135° bend 90° bend B5118489
Gold Combi 28 HE Plus
B5116207
Twin Flue Pipe:
Gold Combi 33 HE Plus
B5116209
The Potterton Gold Combi HE A can be fitted with the following flue systems: Horizontal Concentric
B5115897 0.5 metres
B5116208 1.0 metres 0.25 metres 0.50 metres B5116210
The elbow is now supplied with the flue system (not the appliance) and is not included in any equivalent length calculations. The Multifit flue illustrations show examples of permissible flue lengths. Instructions for guidance and fitting are included in each kit, where appropriate.
Flue System A Flue System G
Vertical Concentric
Flue System A Flue System G
Twin Pipe
Flue System N
Plume Displacement Kit
Flue System K
Vertical Concentric Flues 60/100mm - Flue System A
Horizontal Concentric Flues 60/100mm - Flue System A Item Description (MULTIFIT) Flue System A
Specification
KEY & OD Dimensions
Multifit Sales Code
Item Description (MULTIFIT) Flue System A
Standard Horizontal Flue inc Elbow
685mm
Specification
Key & OD Dimensions
Multifit Sales Code 5118576
60/100mm
5118489
Vertical Flue Terminal
100mm
Standard Horizontal Telescopic Flue 315-500mm inc Elbow
60/100mm
5118069
Roof Cover Plate
125mm
246143
Telescopic Internal Flue Kit
Flue Extension
1000mm
100mm
5111074 5111075
100mm
5119654
Flue Bend
93 degree
100mm
Flue Extension
1000mm
100mm
5111074
Flue Bend (Pair)
135 degree
100mm
5111085
Flue Bend (Pair)
135 degree
100mm
5111085
Flue Bend
135 degree
100mm
5111076
Flue Bend
135 degree
100mm
5111076
Pipe Support
Painted white
Flue Bend
93 degree
100mm
5111075
Pitched Roof Flashing
25 / 50 degree
125mm
5122151
Flat Roof Flashing
125mm
246144
Flue Wall Liner
100mm
5111067
Flue Terminal Deflector
60mm
5111068
100mm
5111080
Pipe Support
Painted white
5111080
Horizontal Concentric Flues 80/125mm - Flue System G Item Description (MULTIFIT) Flue System G
Specification
Horizontal Flue incl boiler & terminal adaptors
Key & OD Dimensions
Multifit Sales Code
125mm
5118580
Flue Extension
1000mm
125mm
5118584
Flue Bend
91.5 degree
125mm
5118588
Flue Bend (pair)
135 degree
125mm
5118597
Pipe Support
For use with 125mm Flue Pipes
125mm
5118610
Vertical Concentric Flues 80/125mm - Flue System G Item Description (MULTIFIT) Flue System G
Specification
Key & OD Dimensions 125mm
5111078
Flue Extension
1000mm
125mm
5118584
Flue Bend
91.5 degree
125mm
5118588
Flue Bend (Pair)
135 degree
125mm
5118597
Vertical Flue Terminal
Multifit Sales Code
Roof Cover Plate
125mm
246143
Flue Vertical Adaptor
100/125mm
5111070
Pitched Roof Flashing
25 / 50 degree
Flat Roof Flashing Pipe Support
For use with 125mm Flue Pipes
125mm
5122151
125mm
246144
125mm
5118610
Twin Pipe Flues 80/80mm - Flue System N Item Description (MULTIFIT) Flue System N
Specification
Vertical Flue Terminal
Key & OD Dimensions
Multifit Sales Code
125mm
5111078
Twin Pipe Extension (Pair inc Brackets)
1000mm
80mm
5111087
Twin Pipe Flue Bend (Pair)
90 degree
80mm
5111072
Twin Pipe Flue Bend (2 Pair)
135 degree
80mm
5111086
125mm
246143
80mm
5120172
Item Description (MULTIFIT) Flue System K
80mm
5111081
80/125mm
5111084
Plume Displacement Kit inc Elbow & clips
Roof Cover Plate Twin Pipe Flue Horizontal Terminal Kit (Pair) Twin Pipe Support (Pair)
Painted White
Twin to Concentric Adaptor 80/80 - 80/125
Plume Displacement 60/100mm Concentric to 60mm PDK - Flue System K Specification
Key & OD Dimensions
Multifit Sales Code
100mm
5118638
1000mm
60mm
5121368
125mm
5122151
Plume Displacement Kit Extension inc clip
Flat Roof Flashing
125mm
246144
Plume Displacement Kit Bend
93 degree
60mm
5121369
Twin Pipe Flue Adaptor (Boiler)
80mm
720089801
Plume Displacement Kit Bend (Pair)
135 degree
60mm
5121370
Pitched Roof Flashing
25 / 50 degree
Optional Accessories Item Description (MULTIFIT)
Specification
Key & OD Dimensions
Multifit Sales Code
Stand Off Kit
Combi and System Boilers only
40mm
5117035
Integral 24 hr Electro-mechanical Timer
Combi Boilers only
Image 1
247206
Integral 7 Day Electronic Timer
Combi Boilers only
Image 2
247207
Wireless Electro Mechanical Timer Room Thermostat
Combi Boilers only
Image 3
5117392
GasSaver
Gold only
Image 5
Expansion Valve Kit
GasSaver only
720055901
Stand Off kit
GasSaver only
720079701
Wireless Digital Timer Room Thermostat
Contacts: General Enquiries Tel:
Image 4 720056901
0844 8711 560 1.
For further information visit: www.pottertongold.co.uk Please note - calls to the contact centre may be recorded or monitored.
2.
3.
4.
5.