HIMOINSA DIESEL GENERATOR FOR TELECOM SOLUTIONS

Page 1


Wide access for maintenance Designs that simplify the maintenance and the servicing

Versatile control panels Himoinsa make their own control panels, ATS, ect. We have flexibility to satisfy all requirements.

Maximum protection Low coolant water level, high coolant temperature and over speed are provided to ensure safe operation

Fuel tanks In addition to the standard ‘day’ fuel tank, which can be connected to remote bulk tanks, we can provide a range of large capacity, double wall fuel tanks. They offer high integrated running

Quality Professional solutions, to the highest level of quality for operating in the most adversus conditions anywhere in the world


Durability Solutions that protect and extend the life of the product

VERSATILITY, EFFICIENCY AND RELIABILITY. SOLUTIONS SPECIALLY DESIGNED FOR TELECOMMUNICATIONS


HIMOINSA has created intelligent solutions that guarantee an uninterrupted supply adapted to the telecommunication sector needs. Among these, hybrid energetic systems that offer a reduced fuel consumption as well as a low operation cost and a longer service intervals. HIMOINSA has used all its experience in the energy sector to create products in the telecommunications field that are rugged, long running and extremely durable. These products cover power from 8 to 45 kVA and they can be tailor-made. A combination of the latest transmission and control technology, adapted with total focus on the specific requirements of the sector. Within this product range we offer compact generating sets that include in addition to the HIMOINSA standard, option range, several optionals such as the protection against high voltage (lighting surge arrestor), dummy load large capacity fuel tanks and high security padlocks.


1 GS + network Genset used as standby to the mains

ENERGY CENTRE

2 GS coupled together Alternating gensets together to provide Prime Power

ENERGY CENTRE

1 GS + batteries

1 GS + batteries + solar panels

Genset as backup of a battery bank

Hybrid system combining solar panel, battery bank

HIMOINSA generating sets can include options that allow control and management of the generating set remotely. Among these options you can find the following: Implementation of a GPS system that helps to keep localized the machine at any moment. Monitoring the fuel levels of the group Tele-management and tele-control of the generating set to gather and register data in real time, alarm notifications set up and report delivery about all energy system.


POWER AND CONTROL

ALTERNATOR

CEA7 (AS5) FITTED ON GENSET, PREHEATING,

3 PHASE SENSING AVR ( +/-1% ) F CLASS DOUBLE VARNISH (GREY PROTECTION)

BATTTERY CHARGER, WITH DIFFERENTIAL SWITCH, START BY DRY CONTACT, IP 55 AC5 FITTED ON GENSET, PREHEATING, BATTTERY CHARGER,NO DIFFERENTIAL SWITCH, START BY DRY CONTACT, IP 55 LIGHTING SURGE ARRESTOR “MAIN LINE CIRCUIT BREAKER

AVAILABLE FUEL TANKS (L) 100 LT TANK 330LT TANK 600LT TANK 750LT TANK 1000LT TANK

(only for switch-over)” LOW COOLING WATER LEVEL SEPARATED PANEL FOR GE1+GE2 REDUNDANT, TIME DEPENDENT SYSTEM WITHOUT MAIN. SEPARATED PANEL FOR GE1+GE2 REDUNDANT,

TIME DEPENDENT, MAIN BACK-UP SYSTEM.

OTHERS DSE 7320 over CEA7 PADLOCKS BAR AND PADLOCKS TOOL KIT DOCUMENTATION HOLDER DUMMY LOAD LIGHT GREY PAINT FINISH

MANY OPTIONS ARE AVAILABLE SPECIALLY DESIGNED FOR THE TELECOMMUNICATION SECTOR, ADAPTED TO THE SPECIFIC NEEDS OF EACH APPLICATION AND CUSTOMER


SINGLE-PHASE MODELS 5 - 20 kVA SINGLE-PHASE GENSET MODEL

HYW 5 M5

HYW 9 M5

3TNM 68

3TNV 76

3TNV 88

4TNV88

4,9 / 4

7,5 / 6

11,9 / 9,5

16,5 / 13,2

5,5 / 4,4

8,3 / 6,6

12,8 / 10,3

17,7 / 14,2

Not required

Not required

Not required

YES

40

40

63

80

HYW 25 M5

HYW 30 M5

HYW 40 M5

Engine model

4TNV 84T

4TNV 98

4TNV 98T

Prime Power (P.R.P.) - kVA / kW

19,5 / 15,6

30 / 24

37 / 30

Engine model Prime Power (P.R.P.) - kVA / kW Stand by Power - kVA / kW 97/68/EC COMPLIANT ATS amperes

HYW 13 M5

HYW 20 M5

25 - 40 kVA SINGLE-PHASE GENSET MODEL

21 / 17,1

33 / 26

40 / 32

97/68/EC COMPLIANT

Stand by Power - kVA / kW

YES

YES

YES

ATS amperes

100

125

160

HYW 6 T5

HYW 8 T5

HYW 13 T5

Engine model

3TNM 68

3TNV 76

3TNV 88

4TNV88

Prime Power (P.R.P.) - kVA / kW

5,4 / 4,3

7,8 / 6,2

12,3 / 9,8

16 / 12,8

Stand by Power - kVA / kW

5,9 / 4,7

8,3 / 6,6

12,5 / 10

17,1 / 13,7

Not required

8,9 / 7,1

13,4 / 10,7

18,3 / 14,6

30

30

30

30

HYW 20 T5

HYW 35 T5

HYW 45 T5

4TNV 84T

4TNV 98

4TNV 98T

Prime Power (P.R.P.) - kVA / kW

20 / 16

34 / 27

41 / 33

Stand by Power - kVA / kW

22 / 18

37 / 30

45 / 36

YES 40

YES 50

YES 63

THREE-PHASE MODELS 6 - 17 kVA THREE-PHASE GENSET MODEL

97/68/EC COMPLIANT ATS amperes 20 - 45 kVA THREE-PHASE GENSET MODEL Engine model

97/68/EC COMPLIANT ATS amperes

HYW 17 T5