WALL TYPES
DRAWING SCHEDULE A1.01 A1.02 A1.03 A1.04 A2.01 A2.02 A2.03 A3.01 A3.02 A4.01 A4.02 A5.01 A5.02 A7.01 A7.02 A8.01 A8.02 A8.02
NOTES AND SCHEDULE LOCATION PLAN SITE PLAN GROUND FLOOR SITE PLAN FIRST FLOOR PROPOSED GROUND FLOOR PLAN PROPOSED FIRST FLOOR PLAN PROPOSED ROOF PLAN PROPOSED ELEVATIONS 1 PROPOSED ELEVATIONS 2 PROPOSED ELECTRICAL / REFLECTED CEILING PLAN - GROUND PROPOSED ELECTRICAL / REFLECTED CEILING PLAN - FIRST PROPOSED SECTION AA PROPOSED SECTION BB INTERNAL LAYOUT - KITCHEN / LAUNDRY INTERNAL LAYOUT - ENSUITE/POWDER WINDOW SCHEDULE 1 WINDOW SCHEDULE 2 DOOR SCHEDULE
01
WALL TYPE 01 CUSTOM ORB EXTERIOR CLADDING FIXED VERTICALLY TO 25MM DEEP TOP HATS @450MM CENTRES WITH APPROVED VAPOUR BARRIER BEHIND. 9MM COMPRESSED CEMENT CLADDING TO EXTERIOR AND INTERIOR FACE FIXED TO 92MM STEEL STUDS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 90MM ROCKWOOL CAVITY INSULATION. SELECT PAINT FINISH. SELECT TILE FINISH TO WET AREA FACE
02
03
WALL TYPE 02 3MM MIN. THICKNESS STEEL CORRUGATED CLADDING APPROVED VAPOUR BARRIER TO INTERNAL FACE. 25MM X 25MM STEEL RAILINGS FIXED HORIZONTALLY TO INTERNAL FACE OF STEEL CORRUGATED CLADDING 51MM OR 64MM STEEL STUDS WALL FRAMING INSTALLED TO MANUFACTURERS INSTRUCTIONS 75MM ROCKWOOL CAVITY INSULATION. 12MM GYPSUM BOARD/ PLASTERBOARD WALL LINING TO INTERNAL FACE (WATER RESISTANT PLASTERBOARD TO WET AREA FACES) SELECT PAINT FINISH TO DRY WALL SELECT TILE FINISH TO WET AREA FACE WALL TYPE 03 9MM COMPRESSED CEMENT CLADDING TO EXTERIOR AND INTERIOR FACE FIXED TO 92MM STEEL STUDS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 90MM ROCKWOOL CAVITY INSULATION. SELECT PAINT FINISH. SELECT TILE FINISH TO WET AREA FACE INTERNAL WALL 76MM STEEL STUDS WITH 12MM PLASTERBOARD WALL LINING TO BOTH FACES (WATER RESISTANT PLASTERBOARD TO WET AREA FACES) 75MM ROCKWOOL CAVITY INSULATION. SELECT PAINT FINISH TO DRY WALL SELECT TILE FINISH TO WET AREA FACE
B
NOTES 1. all water serving property to be mains water. 2. waste water management to be to discharge into existing system, refer to hydraulic engineersdwgs for details. 3. refer geotechnical report for site investigation assessment. 4. all work must comply with requirements of the building code of Australia + general requirements of all relevant authorities 5. the contractor/builder is responsible for setting out + checking all levels + measurements on siteAll dimensions to be verified on site prior to commencing works. figured dimensions to take precedence over scaled work. 6. all structural design/details + drawings to be done by a qualified structural engineer, structural drawings to be read in conjunction with architectural drawings. refer structural engineers drawings for all structural details. 7. refer services engineers drawings for all building services 8. all shop drawings to be submitted to architect/consultant for approval prior to manufacture 9. provide light + ventilation to the requirement of the building code of australia, parts 3.8.4- light +3.8.5-ventilation. provide minimum 25l/s mechanical ventilation to laundry + bathrooms 10. all timber framing to be in accordance with as 1684-timber framing code 11. all concrete works, slabs + footings to be in accordance with as2870-1988 part 1: residential slabs + footings construction 12. all exposed/external steel to be fully galvanised or sand blasted + zinc plated 13. all glazing to be designed in accordance with as1288.2006 + all full height glazing to be 6mm safety glass (grade a) to as1288.2006. External glazing to comply with AS2047. All awnings to bedrooms below 2.0m AFL/GL to have max. wind out of 100mm. 14. roof insulation- "anticon" blanket between u/s of roof deck and topof roof purlins + R3.0 insulation to ceiling / roof cavity 15. provide termite protection via approved chemical barrier in accordance with as 3660.1-2000 builder tp provide details of treatment used +supply certificate upon completion of the works 16. note: internal stair/external stair dimensions treads: 250mm MIN risers: 190mm MAX
BALUSTRADE
17. all collected stormwater to be discharged to nominated stormwater system WALL FINISHES 18. all water ponding areas against house to be collected by drains and connected to stormwater system T01
SELECT WALL TILE 19. flyscreens to all openable windows/ doors + sliding doors. max.apperture to mesh to be 1.8mm.- no aluminium mesh
FLOOR CONSTRUCTION / SUSPENDED FLOORS: 18MM COMPRESSED CEMENT FLOORING FIXED TO STEEL FLOOR FRAMING INSTALLED TO MANUFACTURER’S INSTRUCTIONS. 18MM BAMBOO FLOORING BOARDS OVER COMPRESSED FLOORING 75MM ROCKWOOL INSULATION TO FLOOR CAVITY AND FLAT METAL SHEET BASE COVER TO ENCLOSE FLOOR CAVITY TO UNDERSIDE. 30 MINUTE FIRE RATED COMPRESSED CEMENT LINING TO UNDERSIDES OF FLOOR CAVITY. PRE-DRILL CUT-OUTS FOR SERVICES AS REQUIRED AND INSTALL REMOVABLE COVER-PLATES FOR TRANSPORT. NOTE: TILES TO WET AREAS IN LIEU OF BAMBOO FLOORING, OVER FULLY TANKED COMPRESSED FLOORING, AND CEMENT SCREED. R
ROOF/CEILING CONSTRUCTION: STEEL ROOF DECKING WITH ANTICON BLANKET TO UNDERSIDE @3° PITCH SUSPENDED CEILING SYSTEM 75MM ROCKWOOL CAVITY INSULATION. (2 LAYERS) NOTE R4 INSULATION TO FLOORS/CEILINGS 12MM GYPSUM BOARD/ PLASTERBOARD CEILING LINING TO INTERNAL FACE (WATER RESISTANT PLASTERBOARD TO WET AREA CEILINGS) SELECT PAINT FINISH
20. Lighting: Interior =5W/m² Verandah/Exterior = 4W/m² Garage/Store = 3W/m² 21. NOTE: Waterproofing to wet areas as AS3740. Aluminium angle 'Waterstop' to tile edges in wet areas. Waterproofing to walls to 1.8m H
FLOOR FINISHES F01
FLOOR FINISH 01 TIMBER FLOORING
F02
FLOOR FINISH 02 SELECT TILES TO BATHROOM
F03
FLOOR FINISH 03 CONCRETE SLAB
TD01
TIMBER DECK 01
NOTE *ALL WET AREAS TO BE SET DOWN 50MM
WINDOW SAFETY GLASS: GRADE A SAFETY GLASS TO WINDOWS IN WET AREAS. SMOKE ALARMS: 2 INTERCONNECTED SMOKE ALARMS WITHIN 1.5M OF BEDROOMS & ONE OUTSIDE LAUNDRY.
CEILING TYPES
BUSHFIRE SHUTTERS: BUSHFIRE SHUTTERS WITH TESTNG TO AS 11530.8.2. CERTFICATON TO BE SUPPLIED. HTTPS://SONNENSCHUTZ.COM.AU/FLAME-ZONE-SHUTTERS/ OR EQUAL APPROVED. DECKING: NON-COMBUSTIBLE 19MM UBIQ TIMBER LOOK PENCIL ROUND EDGES WITHOUT GAPS HTTP://WWW.UBIQ.COM.AU/UBIQ-INEXDECKING/ OR JAMES HARDIE HARIEDECK WITHOUT GAPS OR EQUAL APPROVED. HTTP://WWW.JAMESHARDIE.COM.AU/UPLOADS/FILE/2018091976673AJH_HARDIEDECK_INSTALLATTON_GUIDE_060818_WEB.PDF
CL01
12MM PLASTERBOARD CEILING LINING. FLUSH FINISH ON SUSPENDED CEILING SYSTEM. SELECT PAINT FINISH
CL02
12MM WATER RESISTANT PLASTERBOARD CEILING LINING. FLUSH FINISH ON SUSPENDED CEILING SYSTEM. SELECT PAINT FINISH
CL03
6MM COMPRESSED FIBRE CEMENT SOFFIT CLADDING. FLUSH FINISH, SHADOWLINE TO EDGES + TO INTERNAL CONTROL JOINTS. SELECT PAINT FINISH
CL04
0.6MM FLAT METAL STEET TO U/S OF FLOOR STRUCTURE
23 DICKENS ST, NARBETHONG, VIC DRAWING
A1.01
SCHEDULES AND NOTES
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1 ISSUE
BUILDING LICENCE
DATE:
30 JANUARY 2018
SCALE: As
(@ A3)
indicated
11
10
17 41.7 m SETBACK
20 43.2 m SETBACK
CFA
BMO EVELOPE 19M 100.80M
EXISTING 30,000L RWT
19.0 m
100.80M
PROPOSED RESIDENCE 100.80M
DICKENS STREET
17.0 m SETBACK
GRAVEL DRIVEWAY
DRIVEWAY CRUSED ROCK
EXISTING 10,000L RWT
100.80M
SITE AREA 4064m²
RWT 14000L-22000 L
27 PCRZ
0
5
10
20
50m
N
23 DICKENS ST, NARBETHONG, VIC DRAWING
A1.02
LOCATION PLAN
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1 ISSUE
BUILDING LICENCE
DATE:
30 JANUARY 2018
SCALE: 1 : 750 (@ A3)
19.00 m
17.6 m
1.0 m
CFA 14,000L MIN.
RETAINING WALL
1.0 m RL 343.38 m
DRIVEWAY CRUSED ROCK GARAGE RL 343.20 m
RL 343.40 m
19.00 m
1.0 m
19.00 m
7.62 m
RETAINING WALL
19.00 m
RWT
N
23 DICKENS ST, NARBETHONG, VIC DRAWING
A1.03
SITE PLAN GROUND FLOOR
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 200 (@ A3)
17.0 m CFA 14,000L MIN.
ENTRY
RWT
-
N
23 DICKENS ST, NARBETHONG, VIC DRAWING
A1.04
SITE PLAN FIRST FLOOR
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 200 (@ A3)
12200
1400 OVER
8502
1800 W01
1000 90
11020
1000 90
90
9620
1400
LINE OF FLOOR OVER
GAMES
STEP
8000 GARAGE F03 G.02
FFL 343.20 m
D03 G02
s
s
f
90
03
02
FIRST FLOOR OVER
2220
F01 G.03
DECK 02
4000
STORE
FFL 343.40 m
1000
02
W02 G03
1000
f
RETAINING WALL
1 A5.02
RWT
1000
1000 90
11200
3260
3600 OVER
2000 SLIDER
1000 90
5760
11020
90
8510
1800 W02
1890
N
23 DICKENS ST, NARBETHONG, VIC DRAWING
A2.01
FLOOR PLAN GROUND FLOOR
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 100 (@ A3)
OVER
STEP
W03 G03
90
1 A5.01
8m from wall to store wall
D02 G03
02
SOLID FUEL HEATER AND HEARTH
10800 OVERALL
FALL CONCRETE APRON
GRAVEL DRIVEWAY
5000 GARAGE DOOR
03
90
2310 NOM
2220 W03
90 500
6090
10800 600
f D01 G01
5000 GARAGE
s
TD01 ----
3310
f
UP
2810
FFL 343.40 m
03
14.02.19 UDPATES
02
F01 G.01
TD01 ----
insulate RL 343.05 m d bi-fold vertical door for garage
90
W01 G01
s DECK 01
1 A5.01
90
RETAINING WALL
1000
02
90 2220
600
1 A5.02
W04 G01
1890
15800 OVERALL 7800
W08 1.01
01
W06 1.09
BIFOLD
W10 HIGH LEVEL 1.03 WINDOW
01
s W21 1.09
F02 1.03
f
87654321
LOW HEIGHT WALL GLASS OVER
SOLID FUEL HEATER WITH HEARTH
DECK 04
FLUE
4180
4000
2400
s
01
1 A5.01
W11 1.09
UP RL 345.20 m
DINING
990
P'DR F02 1.07
s 01
B
01
O/H
FR
L'DRY
f W19 1.09
f
2910
2830 BED 04
s
W18 1.08
f
900 BED 02
BED 04
BED 03
ENS. 02
F01 1.08
F01 1.06
F02 1.05
R
B
90
2000 w. 650
T.D ----
RL 346.70 m
W14 1.04
D07 1.05
D08 1.06
DECK 05
W13 1.04 D06 1.04
CL01 1.10
D10 1.08
CANOPY OVER
HALL
ST
D09 1.07
F02 WM
W12 1.10
90
1000 CANOPY
W20 1.09
90
360 900 90 800 w.
KITCHEN
F01 1.04
R
01
R
W17 1.08
W16 1.06
W15 1.05
90
12000
12000 OVERALL
FFL 346.70 m
F01 1.09
1 A5.01
CANOPY OVER
T.D. -----
f
LOUNGE
01
1 A5.02
RWT 22,500 L MIN.
90
3910
90
2100 L'DRY
90 1000 90
3340
1000 90
1800 ENS. 2
11800
1500
2000
4000 90
90
3420 BED 04
500 800
2000 W.
3910 DECK 05
2200
90 3420 BED 03
2200
2000 W.
1600 ENS. 2 910
800 W.
90
90 2910 BED 02 3090
15800
N
23 DICKENS ST, NARBETHONG, VIC DRAWING
A2.02
FLOOR PLAN FIRST FLOOR
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 100 (@ A3)
12000 OVERALL
W05 1.09
ENS 01
D04 1.01
4000
s CANOPY OVER
4000
1.03
4000
1.01
W09 HIGH LEVEL 1.02 WINDOW
F01 D05 1.02
F01 1.01
W07 f
RL 346.70 m
2000 CANOPY
90 1000
BED 01
T.D. ----
B
01
WIR
190
2820
1910
R DECK 03
690
1 A5.02
B
1710 90 ENSUITE
90
90
2730
900 w.
90
1420
7710
90
800 90 900 w.
90
5620 BED 01 90 1000 90
2400 w.
90
900 90 800 w.
7710
3000
3010
90
2000 w.
1500 WIR
800
2130 ENSUITE
2000
90
1300
4000 ENTRY DECK
3000
2200
3820 BED 02
1500
ARC FENCES ' BANKSIA' SELECT POWDER FINISH 1M AFL
800 w.
1350
2000 w.
650
0
5800
dp
dp
DECK BELOW
F
FALL FALL
CANOPY
3°
100 F
dp PARAPET WALL
FALL
F
FALL
CHIMNEY
3°
CHIMNEY
R
CANOPY OVER ENTRY
dp
ENTRY STAIRS BELOW
F
RIDGE CAPPING
CANOPY dp
3° DECK BELOW
dp
FALL
F
?
100
dp
RWT 22,500L MIN.
N
23 DICKENS ST, NARBETHONG, VIC DRAWING
A2.03
ROOF PLAN
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 100 (@ A3)
MATERIAL SCHEDULE
02
CORRUGATED METAL CLADDING (DARK)
03
COMPRESSED CEMENT CLADDING PAINT FINISH
STEEL POST / COLUMN
346700 mm
W06 1.09
01
S
W05 1.09
01
F
B
B
A
F
3300
3300 OVERALL
FIRST FLOOR
1700
C
2696
1.0M H STEEL ROD BALUSTRADE
F W08 1.01
200
B
RL 349.40 m
349396 mm
450
ROOF LEVEL
B
B
450
CUSTOM ORB WALL CLADDING
W01 G01
02
1700
01
WINDOW SCHEDULE
NORTH ELEVATION 1 : 100
2696
S
346700 mm
GROUND FLOOR
343200 mm
01
A
W16 1.06
F
F
3300
F
RWT
F 02
A W15 1.05
A W02 G03
SOUTH ELEVATION 1 : 100
23 DICKENS ST, NARBETHONG, VIC DRAWING
A3.01
ELEVATIONS 1
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
450
A
200
3300
FIRST FLOOR
B
W17 1.08
1700
A
F W19 1.09
450
349396 mm
1700
ROOF LEVEL
343200 mm
450
GROUND FLOOR WINDOW AWNING FIXED GLAZING LOUVERED GLAZING OPAQUE / TRANSLUCENT GLAZING SLIDING DOOR / WINDOW
1700
W. A. F. LV. O. S.
30 JANUARY 2018 1 : 100 (@ A3)
F
346700 mm
900
A
A
W10 1.03
W09 1.02
F
RWT
f
s
f
03
03
02
3300
02
1700
W14 1.04
W11 1.09
2150
1700
A
1700
450
01
200
FIRST FLOOR
F
900 349396 mm
2696
ROOF LEVEL
F
GROUND FLOOR
343200 mm
EAST ELEVATION 1 : 100
ROOF LEVEL
F
B
f
f
2696
S
W20 1.09
3500
W21 1.09
2696
B
W18 1.08
01
3296
a 01
1000
2696 346700 mm
S
1000
FIRST FLOOR
F
a
1725
01
W07 1.01
425
349396 mm
W04 G01
D03 G02
F
GARAGE DOOR
W03 G03
S
F 204
S GROUND FLOOR
2150
3500 O/A
03
343200 mm
WEST ELEVATION 1 : 100
23 DICKENS ST, NARBETHONG, VIC DRAWING
A3.02
ELEVATIONS 2
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 100 (@ A3)
CEILING TYPES
W
CL01
12MM PLASTERBOARD CEILING LINING. FLUSH FINISH ON SUSPENDED CEILING SYSTEM. SELECT PAINT FINISH
CL02
12MM WATER RESISTANT PLASTERBOARD CEILING LINING. FLUSH FINISH ON SUSPENDED CEILING SYSTEM. SELECT PAINT FINISH
CL03
6MM COMPRESSED FIBRE CEMENT SOFFIT CLADDING. FLUSH FINISH, SHADOWLINE TO EDGES + TO INTERNAL CONTROL JOINTS. SELECT PAINT FINISH
CL04
0.6MM FLAT METAL STEET TO U/S OF FLOOR STRUCTURE
LIGHTING AND ELECTRICAL
GAMES
DECK 01
CL01 G.01
CL02 ----
D
EQ
E
D
3600
3600
EQ
D P
W
S
1400
STAIRS
F
W2
GARAGE
3600
EQ.
3200
3600
OUTDOOR STAIRS
SMOKE DETECTOR
LIGHT SWITCH
W
TV
STORE
DATA
CL01 G.03
DECK 02 D
CL02 ----
EQ.
TELEVISION POINT DATA POINT
CL04
D
S
D
3600
EXTERNAL GPO DOUBLE GPO
F
1400
F
WALL LIGHT ( INTERNAL) 1800H 7W
EXHAUST FAN
EXT
F
AUTO DETECTOR
CEILING FAN
CL02 G.02
EQ.
PENDANT LIGHT FITTING
WALL LIGHT ( EXTERNAL) 1800H 7W
F
CL02
DOWNLIGHT LED ( INTERIOR) 10W
W1
CHIMNEY FLUE F
DOWN LIGHT (EXTERIOR) 7W
D
3600
EQ.
SURFACE MOUNTED FLUORESCENT TWIN TUBE + TRANSLUCENT DIFFUSER (1200x300MM) 36W
F
W
SKYLIGHT
LED
LED STRIP LIGHT CONTROL JOINT
DB
GROUND FLOOR REFLECTED CEILING PLAN 1 : 100
DISTRIBUTION BOARD NOTES GPO'S GENERAL 100MM AFL TO U/S OF SWITCHING PLATE OR 150MM AFL TO CL OF SWITCHING PLATE GPO'S TO BATHROOMS/ENSUITES /LAUNDRY/MIN 300MM FROM TOP OF BASIN/VANITY TYPICAL SWITCHES @ 1200 AFL CL + 450 MM OFF WALL EDGES CL
23 DICKENS ST, NARBETHONG, VIC DRAWING
A4.01
REFLECTED CEILING PLAN GROUND FLOOR
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1 ISSUE
BUILDING LICENCE
DATE:
30 JANUARY 2018
SCALE: As
(@ A3)
indicated
CEILING TYPES
3600
2100
CL02
12MM WATER RESISTANT PLASTERBOARD CEILING LINING. FLUSH FINISH ON SUSPENDED CEILING SYSTEM. SELECT PAINT FINISH
CL03
6MM COMPRESSED FIBRE CEMENT SOFFIT CLADDING. FLUSH FINISH, SHADOWLINE TO EDGES + TO INTERNAL CONTROL JOINTS. SELECT PAINT FINISH
CL04
0.6MM FLAT METAL STEET TO U/S OF FLOOR STRUCTURE
BED 01
WIR
CL01 1.01
CL01 1.02
D
D
EQ
D
EQ EQ 500
2100
12MM PLASTERBOARD CEILING LINING. FLUSH FINISH ON SUSPENDED CEILING SYSTEM. SELECT PAINT FINISH
1800
EQ
EQ.
CL01
DECK 03 CANOPY CL03
D W1 W1
W1
STAIRS
CL02 1.03
D
EQ
EXT
D P
W1
W1 D
LOUNGE EX
1500
P
P
EX D
EQ.
D
1800
D
1.5M H
DECK 05 CANOPY CL03
W1
1.05M AFL
CL02 D
CL01 1.08 D
CL01 1.10
ENS. 02 CL02 1.05
CL02 1.07 D
BED 03 CL01 1.06
D
EQ
EQ
EXT
EQ
EQ
1500
EXTERNAL GPO DOUBLE GPO
D
BED 02 CL01 1.04
LIGHT SWITCH TV DATA
D
S
TELEVISION POINT DATA POINT SKYLIGHT
ROBE
SURFACE MOUNTED FLUORESCENT TWIN TUBE + TRANSLUCENT DIFFUSER (1200x300MM) 36W
F
EQ
WALL LIGHT ( INTERNAL) 1800H 7W
SMOKE DETECTOR HALL
P'DR
D
EQ
ROBE
BED 04
ROBE
D
W2
W1
D
EXT
AUTO DETECTOR
EXHAUST FAN
LED
D
PENDANT LIGHT FITTING
CEILING FAN
DB
D
EQ
W1
D
EQ.
DOWNLIGHT LED ( INTERIOR) 10W
WALL LIGHT ( EXTERNAL) 1800H 7W
CL03 -----
EQ EQ
P
CL01 1.09
S
DOWN LIGHT (EXTERIOR) 7W
W1
DECK 04
EQ
D
1800
D
WINDOW
2400
D
EQ
E
ENS 01
2 WAY
D
EXT
LIGHTING AND ELECTRICAL
EQ LED
LED STRIP LIGHT CONTROL JOINT
DB
DISTRIBUTION BOARD NOTES GPO'S GENERAL 100MM AFL TO U/S OF SWITCHING PLATE OR 150MM AFL TO CL OF SWITCHING PLATE GPO'S TO BATHROOMS/ENSUITES /LAUNDRY/MIN 300MM FROM TOP OF BASIN/VANITY TYPICAL SWITCHES @ 1200 AFL CL + 450 MM OFF WALL EDGES CL
23 DICKENS ST, NARBETHONG, VIC DRAWING
A4.02
REFLECTED CEILING PLAN FIRST FLOOR
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1 ISSUE
BUILDING LICENCE
DATE:
30 JANUARY 2018
SCALE: As
(@ A3)
indicated
R
ROOF LEVEL
349396 mm
CL04
CL01 01
W06 1.09
2496
2696
W05 1.09
LOUNGE
F
S D04 1.01
W.
01
W11 1.09
1.09
F01 FIRST FLOOR
B
B
B
RL 346.70 m
346700 mm
RL 346.50 m
CL02
CL04 1500
CL02
RL 346.70 m
03 03
GARAGE
D03 G02
G.02
3300
3500
RL 345.20 m
D01 G01
SOLID FUEL HEATER S GROUND FLOOR
343200 mm
RL 343.20 m
F
F03 STEP
SECTION AA 1 : 50
23 DICKENS ST, NARBETHONG, VIC DRAWING
A5.01
SECTION AA
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 50 (@ A3)
R
3° ROOF LEVEL
3°
3°
349396 mm
01
W07 1.01
FIRST FLOOR
BED 04 01
2400
01
2496
2496
LOUNGE 1.09 CL01
1.08 CL01
2400 CEILING
W17 1.08
W11 1.09
RL 15.69 m
346700 mm
02
02
02
1200
G.02
STORE 2800
GARAGE
G.01
D02 G03
2400 STORE
GAMES
3300 CLEAR
2400
RETAINING WALL
3500 O/A
02
G.03
RETAINING WALL
343200 mm
SPOON DRAIN NOTE: FALL PATHWAYS AWAY FROM BUILDING
200
150MM CONCRETE SLAB GROUND FLOOR
200
200
1200
CONCRETE FOOTINGS TO S.ENG. DETAILS
CONCRETE FOOTINGS TO S.ENG. DETAILS
23 DICKENS ST, NARBETHONG, VIC DRAWING
A5.02
SECTION BB
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 50 (@ A3)
SPOON DRAIN NOTE: FALL PATHWAYS AWAY FROM BUILDING
1000
2856
2692
FIRST FLOOR
346700 mm
590
651
1000
900
FR.
FR
INTERNAL KITCHEN 1 : 50
KITCHEN AND ISLAND ELEVATION 1 : 50
KITCHEN PLAN 1 : 50
FIRST FLOOR
346700 mm
ELEVATION ISLAND 1 : 50 2100
990
600
390
2100
FIRST FLOOR
346700 mm
LAUNDRY PLAN 1 : 50
LAUNDRY INTERNAL 1 : 50
LAUNDRY SECTION 1 : 50
23 DICKENS ST, NARBETHONG, VIC DRAWING
A7.01
INTERNAL ELEVATIONS
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 50 (@ A3)
1230
1710 800
800
900
1710
200
ENS 01
D05 1.03
2130
1330
D05 1.03
F02 1.03
W10 1.03
800
W10 1.03
ENSUITE 01 1 : 50
ENS. 01 1 1 : 50
ENS. 01 2 1 : 50
ENS. 01 3 1 : 50
ENS. 01 4 1 : 50
W15 1.05
F02 1.05
ENSUITE 02 1 : 50
2400
D07 1.05
ENS. 02 1 1 : 50
ENS. 02 3 1 : 50
ENS. 02 2 1 : 50
ENS. 02 4 1 : 50
P'DR F02 1.07
2400
2830
ENS. 02
POWDER ROOM 1 : 50
23 DICKENS ST, NARBETHONG, VIC
P'DR 1 1 : 50
DRAWING
A7.02
PDR 2 1 : 50 INTERNAL ELEVATIONS 2
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 50 (@ A3)
23 DICKENS ST, NARBETHONG, VIC DRAWING
A-10
VIEWS
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 (@ A3)
23 DICKENS ST, NARBETHONG, VIC DRAWING
A-11
VIEWS 2
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 (@ A3)
NOTE NOTE: MANUFACTURER TO CONFIRM GLAZING MEETS RELEVANT AUSTRALIAN STANDARDS ALL WINDOWS ARE DOUBLE-GLAZED TO MANUFACTURERS SPECIFICATIONS 6 MM AIR GAP AND 6 MM INTERNAL GLAZING 1800
2220
1800
FOR ALUMNINIUM WINDOWS AND DOORS:
2220
Fixed windows – 638ComPlyGry-8Ar-4mmClr (code AWS-067-01) U-Value 2.53, SHGC 0.39 Awning windows – 638ComPlyGry-8Ar-4 (code AWS-008-14) U-Value 3.69, SHGC 0.32 Sliding doors – 638GyLam-12-6 (code AWS-02525) U-Value 3.96, SHGC 0.20
450
F
450
A
F
A
2000
2000
A F LV O S B
2000
B
B
F
S
900
900
A
A
1700
F
2150
2150
S
2150
F
AWNING FIXED GLAZING LOUVERED GLAZING OPAQUE / TRANSLUCENT GLAZING SLIDING DOOR / WINDOW BI-FOLD DOOR / WINDOW
B
W05 1.09
W06 1.09
W07 1.01
W08 1.01
W09 1.02 CAPRAL DOUBLE GLAZED FRAME OR SIMILAR FRAMING FIXED WINDOW+ AWNING WINDOW SELECT POWDERCOAT FINISH
CAPRAL FRAME OR SIMILAR FRAMING FIXED WINDOW + 889 SLIDING DOOR SELECT POWDERCOAT FINISH
23 DICKENS ST, NARBETHONG, VIC DRAWING
A-12
WINDOWS SCHEDULE 1
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 50 (@ A3)
450
3000
W04 G01
1700
W03 G03
450
W02 G03
F
GENERAL NOTES 1. ALL DIMENSIONS TO BE VERIFIED ON SITE 2. ALL EXTERNAL WINDOWS TO HAVE FLY SCREENS
F
1700
W01 G01
S
450
S
2150
2150
1700
1700
Sliding windows – 638CPGy-8Ar-4 (code AWS003-14) U-Value 3.55, SHGC 0.34
W10 1.03
NOTE NOTE: MANUFACTURER TO CONFIRM GLAZING MEETS RELEVANT AUSTRALIAN STANDARDS ALL WINDOWS ARE DOUBLE-GLAZED TO MANUFACTURERS SPECIFICATIONS 6 MM AIR GAP AND 6 MM INTERNAL GLAZING 2400
900
900
900
FOR ALUMNINIUM WINDOWS AND DOORS:
800
Fixed windows – 638ComPlyGry-8Ar-4mmClr (code AWS-067-01) U-Value 2.53, SHGC 0.39
A
Sliding doors – 638GyLam-12-6 (code AWS-02525) U-Value 3.96, SHGC 0.20
450
A
450
F
450
450
Awning windows – 638ComPlyGry-8Ar-4 (code AWS-008-14) U-Value 3.69, SHGC 0.32 A
AWNING FIXED GLAZING LOUVERED GLAZING OPAQUE / TRANSLUCENT GLAZING SLIDING DOOR / WINDOW BI-FOLD DOOR / WINDOW
S
W17 1.08
W18 1.08
F
f
W19 1.09
A-13
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
W21 1.09
CAPRAL DOUBLE GLAZED FRAME OR SIMILAR FRAMING FIXED WINDOW+ AWNING WINDOW SELECT POWDERCOAT FINISH
23 DICKENS ST, NARBETHONG, VIC WINDOWS SCHEDULE 2
450
f
W20 1.09
CAPRAL FRAME OR SIMILAR FRAMING FIXED WINDOW + 889 SLIDING DOOR SELECT POWDERCOAT FINISH
DRAWING
1700
F
a
2150
a
S
800
450
800
30 JANUARY 2018 1 : 50 (@ A3)
2150
A F LV O S B
2000
F
W16 1.06
1700
1700
1700
2150
W15 1.05
450
A
F
W14 1.04
2000
2150
A
1700 F
W13 1.04
2000
450
2000
A
2150
W12 1.10
1700
W11 1.09
F
F
F
GENERAL NOTES 1. ALL DIMENSIONS TO BE VERIFIED ON SITE 2. ALL EXTERNAL WINDOWS TO HAVE FLY SCREENS
2150
f
2150
s
1700
f
1700
2150
Sliding windows – 638CPGy-8Ar-4 (code AWS003-14) U-Value 3.55, SHGC 0.34
5000
2150
2400
2000
2150
2000
S
F
F D01 G01
S
D02 G.03
D03 G02
ALUMINIUM FRAMED, GLASS SLIDING DOORS
820
820
820
820
820
820
H
S D04 1.01
H D05 1.03
H
D06
H
D07
D08
H
H
D09
D10
DOOR MATERIAL: FRAMES: ARCHITRAVES
23 DICKENS ST, NARBETHONG, VIC DRAWING
A-14
DOOR SCHEDULE
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
2150
2150
2150
2150
2150
2150
2150
850
30 JANUARY 2018 1 : 50 (@ A3)
INDICATIVE ROOF FALL ARRANGEMENT 1 : 50
23 DICKENS ST, NARBETHONG, VIC DRAWING
A-15
BALCONY DRAINAGE DETAIL
* DO NOT SCALE OFF DRAWINGS, USE GIVEN DIMENSIONS ONLY
1
BUILDING LICENCE
DATE: SCALE:
ISSUE
30 JANUARY 2018 1 : 50 (@ A3)