Viega PEX for Reclaimed Water Sell Sheet

Page 1

ViegaPEX™ Tubing

PEX for Reclaimed Water

As water supplies continue to diminish, the desire and

collection, water is run through an in-home filtration

need to reuse water has been a growing trend. To meet

system, and then reused in other areas of the home

this demand, Viega has added reclaimed water tubing to

such as laundry, toilets and irrigation systems. ViegaPEX

the ViegaPEX line.

tubing for reclaimed water comes to the market with the

The process of water reclamation varies. Often after

trust that professionals have already established with ViegaPEX systems.


New

ViegaPEX tubing - For reclaimed water - Not for potable water applications - PEX - Coil Technical Data PEX designation code 5006 ASTM F876, ASTM F877 Model V5009.7

Features and benefits • Highest rating for chlorine resistance

d ½ ¾ 1 1)

L [ft] 300 300 300

Version purple purple purple

Wt [lb] 17.100 32.100 51.000

Quantity 1 1 1

U.S. factory for the greatest quality control • Aids a home in receiving LEED® or National Green Building Standard™ points • System-matched tools and jaws make consistent connections • 25-year limited warranty

What types of reclaimed water exist? Blackwater:

Greywater:

Toilets

Showers, sinks, washing machines

Clearwater:

Stormwater:

Rainwater off the roof, condensation from appliances (except boilers), groundwater from sump pumps

• cNSF®us-rw certified listed for reclaimed water use (non-potable use only)

Originates during precipitation events and snow/ice melt

How Much Water Do We Use? Toilet Clothes Washer

26.7% 21.7%

Shower

Certifications

DG 1 1 1

center pull coil

• Available in sizes ½" to 1", 300 ft. coil lengths • Resin is manufactured and tubing is extruded in our

Part No 329111 329121 329131

16.8% 15.7%

Faucet

13.7%

Leaks Other

5.3%

Source: American Water Works Association Research Foundation, “Residential End Uses of Water.” 1999

• ICC ES-PMG™ 1038 plumbing applications • UL 263 and CAN/ULC S101 (US and Canadian fire resistance ratings) • ASTM E84 and CAN/ULC S102.2 • FS/SD (25/50) (US and Canadian plenum rating)

Some examples show 38% savings in potable water usage.*

* 38% of the potable water in New York City's Solaire condos is reduced by using reclaimed water, according to Pelli Clarke Pelli Architects LEED® is a registered trademark of the U.S. Green Building Council®

Viega LLC phone: 800-976-9819 e-mail: insidesales@viega.us web: www.viega.us

1017-V_EN_0316_1

1

3.1

PEX Press


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.