Creative Proteomics: Flow Cytometry vs Microscopy

Page 1

FLOW CYTOMETRY

FLUORESCENCE MICROSCOPY

Flow Cytometry and Fluorescence Microscopy Flow Cytometry (FC) determines mul�ple physical and biological characteris�cs of cells by detec�ng the intensity of the sca�ered or emi�ed light of a single cell in a linear flow state before laser irradia�on. This technology can analyze cells rapidly at a rate of tens of thousands of cells per second. The types of samples can be various types of cells (such as peripheral blood, bone marrow, solid �ssues, cells in suspension or adherent culture), microorganisms, synthe�c microspheres, etc.

Sample (Mixture of cells) Non-target cell

RFP do not bind (No fluorescence)

An�body RFP labelled

Mixture of cells (Sample)

Target cells (fluorescent)

Op�cs/Laser

Target cell expressing specific protein

Fluorescent detector Sca�ered light detector (Fwd/side)

RFP binds and cell fluoresces red

Waste

A fluorescence microscope is an enhanced op�cal microscope that uses a higher intensity of light to excite the fluorophore in a sample. The fluorophores, in turn, emit a lower energy light with a longer wavelength that produces the magnified image. The loca�on of specific cell types of intracellular molecules in �ssue can be observed using a fluorescence microscope. Detector

Ocular

Excita�on filter Dichroic mirror

Light source Objec�ve

Specimen

Comparing the Two in Cell Analysis Flow Cytometry

Features

Throughput

Sensitivity Number of parameters detected on a single cell Complexity and cost

Applications

Flow cytometers o�en cannot specify the exact loca�on of components inside the cell. When flow cytometry quan�fies cell composi�on, it is performed at the whole cell level, while fluorescence microscopy can quan�fy the composi�on of the cell compartment.

Fluorescence microscopy can show how a component is distributed in the cells, uniformly or clustered in the anatomical compartment. It can also indicate the change (or not) in concentra�on over�me.

Up to 100,000 cells per second

Several hundreds of cells per second with specific imaging instrumenta�on

Depends on the fluorochromes, experimental design, and instrumenta�on

Depends on fluorochrome choice and exposure �me

Up to 30 on a single cell

Up to 6 on a single cell with special instruments

The more parameters needed, the more complex and costly instruments and so�ware will be

More complex experiments require more expensive instruments and so�ware

Cell sor�ng: physical separa�on and collec�on of user-defined cell popula�ons with specialized sorter

Cell sor�ng: not possible

Rare cell detec�on: easily performed

RNA detec�on: easily visualized, new assays allowed to develop mul�parametric analysis

RNA detec�on: specialized assays required to detect RNA and protein expression Structural/morphological data: imaging cytometers are available for this purpose Kine�c/�me-lapse data: possible but challenging

Email: info@creative-proteomics.com Tel: 1-631-275-3058

Fluorescence Microscopy

© 2008-2021 Creative Proteomics. All rights reserved.

Rare cell detec�on: �me-consuming to iden�fy without so�ware or instrumenta�on

Structural/morphological data: major strength of this technique Kine�c/�me-lapse data: rou�nely done


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.