SMARTY SAVER SEMI AUTOMATIC
USEFUL INFORMATION FOR BUYING A DEFIBRILLATOR
WHAT IS A DEFIBRILLATOR?
Defibrillators are used when a person is in cardiac arrest. They deliver an energy shock to the heart (defibrillation).
Defibrillators are known by several names, including:
• AED
• Automated External Defibrillator
• Defib
• Defibrillator
• Public Access Defibrillator (PADs)
HOW TO USE A DEFIBRILLATOR
Defibrillators should be easily accessible in all settings. In an instance where one is locked in a cabinet, instructions on how to get in will be provided. Visual and audible instructions are also provided to enable the person to deliver CPR with the defibrillator. Defibrillation within the first three minutes of cardiac arrest can increase chances of survival by up to 70%, reducing at approximately 10% per minute after this.
TYPES OF DEFIBRILLATOR
There are two types of defibrillator; Semi-Automatic and Fully Automatic. Semi-automatic defibs require the rescuer to press a button to deliver a shock, whereas fully automatic defibrillators deliver them automatically.
MAINTENANCE
• Check the defibrillator regularly and ensure they are accessible
• Ensure there are no fault warnings on the defib
• Ensure all pads are within their expected life
• Ensure batteries have sufficient charge
SMARTY SAVER SEMI AUTOMATIC
LIGHTWEIGHT
INSTANT
The basic model of the Smarty Saver Series line is very affordable and easy to use. Reliable and durable {l meter drop test - dustproof and waterproof resistance IP rate 56). It can be easily operated by anyone in the medical field (e.g. ambulance, emergency room, etc.) and non-medical field too (e.g. public or private places).
The Semi-Automatic model analyses the patient’s ECG and if a shockable rhythm is detected it automatically starts charging the reservoir capacitor. The AED vocal message will suggest the operator presses the shock button to deliver the de-fibrillating shock.

If CPR is required, ensure the emergency services are called with 999 or 112, and send for the AED.
In CPR, do 30 chest compressions, followed by 2 rescue breaths. Do this at a rate of 100 to 120 compressions per minute.
When the AED is available and needed, turn on the device, remove clothing, and attach pads. Ensure nobody is touching the casualty, as this can interfere with the AED. FOLLOW INSTRUCTIONS GIVEN BY THE DEFIBRILLATOR
To book a first aid training course, visit www.wallacecamerontraining.com, call 01698 354 671 or email chrisc@wallacecameron.com
Charging time from shock alert*
Charging time from analysis time*
Analysis time
IEC60601-2-4 ≤ 9 sec with shock at 150J ≤ 12 sec with shock at 200J
IEC60601-2-4 ≤ 13 sec with shock at 150J ≤ 16 sec with shock at 200J
IEC/EN 60601-2-4 from 4 to 15 seconds
Adult: incremental first 150J - subsequent 200J Paediatric: fixed 50J
IEC60601-2-4 ≤ 9 sec with shock at 150J ≤ 12 sec with shock at 200J
IEC60601-2-4
≤ 13 sec with shock at 150J ≤ 16 sec with shock at 200J
IEC/EN 60601-2-4 from 4 to 15 seconds
Adult: incremental first 150J - subsequent 200J Paediatric: fixed 50J
IEC60601-2-4 ≤ 9 sec with shock at 150J ≤ 12 sec with shock at 200J
IEC60601-2-4
≤ 13 sec with shock at 150J ≤ 16 sec with shock at 200J
IEC/EN 60601-2-4 from 4 to 15 seconds
Impedance range 20-200 Ohms 20-200 Ohms 20-200 Ohms
Sensitivity 97% (IEC/EN 60601-2-4) 97% (IEC/EN 60601-2-4) 97% (IEC/EN 60601-2-4)
Specificity 99% (IEC/EN 60601-2-4) 99% (IEC/EN 60601-2-4) 99% (IEC/EN 60601-2-4)
Controls
Semi-automatic model N/A
Controls
Fully Automatic model
Light indicators
4 buttons: ON/OFF, shock delivery, Patient selection (adult/child)
3 buttons: ON/OFF, patient selection (adult/child) N/A
Device status: 2 LEDs red/green PADs placement: 2 red LEDs
Do not touch the patient: 2 red LEDs
Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs
Device status: 2 LEDs red/green PADs placement: 2 red LEDs Do not touch the patient: 2 red LEDs Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs
6 buttons: ON/OFF, shock delivery, patient selection (adult/child), live call, ECG streaming
5 buttons: ON/OFF, patient selection (adult/child), live call, ECG streaming
Device status: 2 LEDs red/green PADs placement: 2 red LEDs Do not touch the patient: 2 red LEDs Touch the patient: 1 green LED Adult patient: 1 green LED Paediatric patient: 1 green LED ON/OFF button: 2 green LEDs Shock button: 8 red LEDs CPR Quality feedback 8 LED bar: 2
streaming: 1 green blinking
EVENT RECORDING
Optional external memory
Stored data
“AEDl LOG.txt”: text file with detailed report of self- test activities and power ups
“AEDFILE.aed”: ECG trace, rescue events, voices and background audio
“AEDl LOG.txt”: text file with detailed report of self- test activities and power ups “AEDFILE.aed”: ECG trace, rescue events, voices and background audio
“AEDl LOG.txt”: text file with detailed report of self- test activities and power ups
“AEDFILE.aed”: ECG trace, rescue events, voices and background audio “AEDFILE.aed”review Through
DEFIBRILLATION PADS
Type
Dimensions
Shelf-life
BATTERY
Type
Voltage/capacity
Autonomy
Code SMT-C2001: Disposable, universal, pre- gelled, preconnected
Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face-to-Face
Total surface 136cm2; active surface 94cm2; 120cm cable length (external to packaging)
24-30 months, as indicated on the packaging
Code SMT-Cl 4032: Disposable battery 8 cells Li-Mn02
Code SMT-C2001: Disposable, universal, pre- gelled, preconnected
Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face-to-Face
Total surface 136cm2; active surface 94cm2 ; 120cm cable length (external to packaging)
24-30 months, as indicated on the packaging
Code SMT-Cl 4031: Disposable battery 8 cells Li-MnO2
Code SMT-C2001: Disposable, universal, pre- gelled, preconnected
Code SMT-C2002: Disposable, universal, pre- gelled, preconnected, Face- to- Face
Total surface 136cm2; active surface 94cm2; 120cm cable length (external to packaging)
24-30 months, as indicated on the packaging
Code SMT-Cl 4031: Disposable battery 8 cells Li-MnO2
Ah l 2VDC- 3000mAh 12VDC-3000mAh 12VDC-3000mAh
Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*
Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*
Up to 200 complete rescue cycles (200J shocks + CPR); Up to 36 hours of continuous ECG analysis*
Stand by life
to 3 years with a battery insertion test and daily self-test without any turning on the AED*
to 3 years with a battery insertion test and daily self-test without