GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
E.O. Nº: Revision: Rev. date: Page:
ENGINEERING ORDER
SB-28-0124 00 15/Nov/2010 1 de 9
Subject: FUEL - GENERAL - REVISE THE ELECTRICAL BONDING OF THE EQUIPMENT IN THE FUEL TANKS – ADDITIONAL WORK
Reference Documents: Description
Type
Number
Rev.
Date (d/m/y)
FUEL - GENERAL - REVISE THE ELECTRICAL BONDING OF THE EQUIPMENT IN THE FUEL TANKS
SB
A340-28-4097
05
03/Jun/10
FUEL - GENERAL - REVISE THE ELECTRICAL BONDING OF THE EQUIPMENT IN THE FUEL TANKS
SBIT
SEMB/914.0701/09
--
29/Oct/09
AC Configuration modified (Y/N): N
Rotable Inventory modified (Y/N): N
337/SEG VOO or equiv. required (Y/N): N
Summary
The ADDITIONAL WORK required by this EO is only applicable to aircraft on which the Revision 03 or any previous revision of Airbus Service Bulletin A340-28-4097 has been embodied by means of accomplishment of LAN Engineering Orders AD-28-0086 or AD-28-0087 as per A/C applicability. The embodiment of SB A340-28-4097 was mandated by the requirements of EASA AD 2007-0278.
Prepared by:
Reviewed by:
Constantino Restrepo P. Aircraft System Engineer
Luis A. Ramirez C. Lic. Ing. Esp. DGAC 138 System Group Leader
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
I Revision Control Record Items Rev. Affected Nยบ
All
00
ENGINEERING ORDER Description of Change
Initial Release
E.O. Nยบ: Revision: Rev. date: Page:
SB-28-0124 00 15/Nov/2010 2 de 9
Approval Name / Date
Luis Ramirez C Systems Group Leader Base Engineering Date: ___ / ____ / 2010
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
E.O. Nยบ: Revision: Rev. date: Page:
ENGINEERING ORDER
SB-28-0124 00 15/Nov/2010 3 de 9
II Cost information EO issued for the following reason Airworthiness: Commercial:
Contractual:
Reliability: X
III Parts List
REFER TO MODIFICATION JIC ON MAINTENIX IV Required Equipment and Tools
REFER TO MODIFICATION JIC ON MAINTENIX V Required Drawings Item N/A
Drawing Number N/A
Rev N/A
Description
Remarks N/A
N/A
VI Weight and Balance change It is required to update W&B report after accomplishment of this EO? (Y/N/Calc): Item Weight (lbs) Arm (in)
TOTAL
N/A
N/A
N Moment (lbs-in)
N/A
VII Electrical Load changes It is required to update the Electrical Load after accomplishment of this EO? (Y/N): Element Removed Load Added Load
TOTAL
N/A
N/A
N Affected Bus
N/A
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
AREA
EQUIPMENT & SYSTEMS Water Drain
Rib 2-3
Rib (RH)
18-19
Ventilation Intake System
Qty 2 2 4
Qty 4 2 2 2 2 2 2 2 2
E.O. Nยบ: Revision: Rev. date: Page:
ENGINEERING ORDER Table 1. ELECTRICAL BONDING METHOD Install the bonding lead. Bond the pipe clamp to the pipe. Bond the bolt to the structure. Bond the contact surfaces between Elbow and Flame arrestor. Bond two of the unions of the Elbow and Flame arrestor.
Table 2. Description screw Item (1) washer Item (2) rivet Item (3)
Figure
Kit No.
Refer to figure 1, Sheet 1 and Sheet 2
284097C 02S01
Refer figure 2
None
to
SB-28-0124 00 15/Nov/2010 4 de 9
Action Retain Retain Discard
Table 3 Description rivet MS20470AD5-10A Item 3 bonding lead F2818007601200 Item 4 screw Item (1) washer Item (2) clamp NSA5519-4B Item 7 screw NAS1096-1-7 Item 5 washer NAS1149DN632K item 6 washer NAS1149DN616H item 8 nut MS21042-06 Item 9
Qty 4 4 4 1
Table 4. Description bolt Item (15) washer Item (16) nut Item (3) O-ring Item (18)
Action Retain Retain Retain Retain
Qty 4 4 4 1
Table 5. Description bolt Item (15) washer Item (16) nut Item (3) O-ring Item (18)
Action Install Install Install Install
Action Install Install Install Install Install Install Install Install Install
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
ENGINEERING ORDER
E.O. Nยบ: Revision: Rev. date: Page:
SB-28-0124 00 15/Nov/2010 5 de 9
Figure 1 Sheet 1 Electrical Bonding Installation Water Drain System
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
ENGINEERING ORDER
E.O. Nยบ: Revision: Rev. date: Page:
SB-28-0124 00 15/Nov/2010 6 de 9
Figure 1 Sheet 2 Electrical Bonding Installation Water Drain System Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
ENGINEERING ORDER
E.O. Nยบ: Revision: Rev. date: Page:
SB-28-0124 00 15/Nov/2010 7 de 9
Figure 2 Electrical Bonding Installation Ventilation Intake System Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
ENGINEERING ORDER
E.O. Nยบ: Revision: Rev. date: Page:
SB-28-0124 00 15/Nov/2010 8 de 9
Engineering Deviation Authorization E.O. Step and Comments
Authorized Deviation
References
(application must be signed here)
Engineering Approval Signature
Mechanic License Nยบ & Signature
Inspector License Nยบ & Signature
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director
GERENCIA DE SOPORTE TECNICO SUBGERENCIA DE INGENIERIA
ENGINEERING ORDER
E.O. Nยบ: Revision: Rev. date: Page:
SB-28-0124 00 15/Nov/2010 9 de 9
Discrepancy Report Discrepancy Nr.
Mechanic License Nr. & Signature
Inspector. License. Nยบ & Signature
Lan Engineering Services This document and attachment are Lan property and can not be used, copied o given to any other party without the written authorization of the Engineering Director