Refrigerant PFD final

Page 1

C-501 Primary Compressor 8292 kW

C-502 Compressor 2 6432 kW

C-503 Compressor 3 234.5 kW

E-502 Interstage Cooler 1785 m2 11.4 GJ/hr

E-501 Condensor 144 GJ/hr

E-303a 9.5 GJ/hr

E-407 68.8 GJ/hr

E-409a 7.9 GJ/hr

E-503 Precooler 1011 m2 33.6 GJ/hr

E-410a 7.9 GJ/hr

S-5012

V-501 Primary Knockout Drum 1.2 m-D x 6.7 m-H

E-303b 3.8 GJ/hr

E-408 27.4 GJ/hr

V-502 Secondary Knockout Drum 0.6 m-D x 6.7 m-H

E-409b 3.9 GJ/hr

E-410b 4.0 GJ/hr

S-5010

8900 kg-mol/hr

6 atm 13.3 C

1727 kg-mol/hr

6 atm 35.6 C S-5016

2731 kg-mol/hr

Used Cold Water

6 atm 10 C

S-5025

S-5001

C-503

6 atm 10 C 17 atm 93.3 C

17 atm 65.5 C

41 atm 166 C

41 atm 87.8 C

S-5002

S-5003

S-5004

S-5005

40 atm 78.8 C

S-5006

6 atm 10 C

437 kg-mol/hr S-5021

C-502

E-303a

E-501

C-501

E-502

S-5007

E-503

3162 kg-mol/hr

V-501 E-407

TIC I-1 6169 kg-mol/hr

370 kg-mol/hr

E-409a

S-5013 Cold Water S-5015

6 atm 10 C

370 kg-mol/hr 3.4 atm -5.6 C

E-410a

108 kg-mol/hr

S-5011

168 kg-mol/hr 3.4 atm -5.6 C 1835 kg-mol/hr

E-303b

S-5008 1209 kg-mol/hr

E-408

V-502 174 kg-mol/hr 3.4 atm -5.6 C

E-409b

S-5009 1727 kg-mol/hr

176 kg-mol/hr

PLANT LOCATION – REPUBLIC OF TATARSTAN, RUSSIA E-410b

AMMONIA PROCESSING PLANT REFRIGERATION SYSTEM PROCESS FLOW DIAGRAM

SECTION 5 - UTILITIES APPROVED BY: CRYSTAL LIN, PM

MY CHEMICAL ROMANCE SOLUTION INC. LOS ANGELES, CALIFORNIA SCALE

PROJECT NUMBER

DRAWING NUMBER

REV

NONE

01-2012

108A-PANG-108B

5

DATE

06-06-2012

CLIENT – HP CHEMICAL

SHEET

1 OF 3


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.