Airfel DIGIFEL PREMIX Condensing Combi Boiler

Page 1

DIGIFEL PREMIX

Condensing Combi Boiler

24,30,38 kW

Thermal Efficiency

A

Energy Efficiency

Capacity

Quiet Operation

LCD Display

Premix Combustion


DIGIFEL PREMIX

Condensing Combi Boiler Digifel Premix, the new full condensing combi boiler of Airfel ErP, your safe and reliable brand, offers efficiency and energy saving with its frequency controlled pump and full flame modulation and complies with the regulations. Being in class 5 in NOx emissions, it is environmentally-friendly and eco-conscious. Airfel Digifel Premix hermetic full condensing combi boiler is durable and long lasting thanks to its stainless steel heat exchanger. It provides energy saving while offering highest level of comfort. It has a wide modulation range of 20% to 100%. Energy saving Airfel Digifel Premix full condensing combi boiler is consumer friendly and easy to use. This ultimate Airfel Digifel Premix combi complies with all flue connections of C13, C13x, C33, C43, C53, C63, C83, B23,B23P, B33, B33P. While taking one step ahead in energy performance and saving, Airfel Premix full condensing combi boiler has also increased the domestic water performance with its new stainless steel heat exchanger. CO2 emissions have decreased significantly. Specialized in quality, comfort, safety and saving, Airfel Digifel Premix full condensing combi boiler increases energy performance thanks to its Cold Burner technology in stainless steel heat exchanger.

24 kW, 30 kW and 38 kW thermal capacity options Complies with ErP directives Wide modulation range: 20% to 100% Full combustion technology with Premix burner High efficiency up to %108 (according to EN 677) High fuel saving with condensing technology New generation stainless steel heat exchanger Frequency controlled fan Frequency controlled PWM pump Higher energy performance with Cold Burner technology N0x class 5 Environmentally-friendly with low emission rates Diagnostic and safety systems Compatible with solar energy Ability to operate with boiler (optional) Integrated operation with outdoor sensor (optional) Integrated operation with room thermostat (optional) Manufactured in Daikin factories.


Energy Performance Heating Circuit

A2CPX030BATR

A2CPX038BATR

22,8

28,8

36,2

kW

Rated Thermal Load Min.

kW

4

4,8

6

Max./Min. Heating Power (80/600)

kW

3,7 - 22

4,5 - 27,9

5,7 – 35

108 %

Max./Min. Heating Power (50/300)

kW

4,3 - 24,1

5,2- 30

6,5 - 38

96,5

96,8

96,8

Energy Efficiency

Capacity

%

Thermal Efficiency

Quiet Operation

Compact Size

LCD Display

Thermal Efficiency at Rated Load (80/600) Thermal Efficiency at Rated Load (50/300)

%

105,7

104,1

104,9

Thermal Efficiency at Return Temperature 30°C

%

107,2

107,9

108,1

Efficiency Class |1 ( EN 15502)

-

A

A

A

N0x class

-

5

5

5

Waste Gas Temperature (G20) Minimum Operating Pressure Maximum Operating Pressure Expansion Tank Capacity Expansion Tank Initial Pressure

-

86

93,8

89,8

Bar

0,3

0,3

0,3

Bar

3

3

3

Liter

7

8

12

Bar

0,75

0,75

0,75

20/80

20/80

20/80

40/60

40/60

40/60

10

13

16

XL

XL

XL

2

2

2

Heating Circuit Temperature Range Min./Max.

Domestic Water Circuit

A2CPX024BATR Rated Thermal Load Max.

Domestic Water Temperature Min./Max. Hot Water Amount ΔT=30 °K

Liter/Min.

Domestic Water Profile (Ecodesign Lot2) Minimum Hot Water Flow

10/1

10/1

10/1

~230/50

~230/50

~230/50

Elektrical Data

Bar V/Hz

Supply Voltage Electrical Power

w

83

87

115

Electrical Protection Class

IP

X5D

X5D

X5D

Gas Pressure & Consumption

Plumbing Pressure Max./Min.

Liter/Min.

Natural Gas (G20) Inlet Pressure

mbar

21

21

21

LPG (G30/G31) Inlet Pressure

mbar

30/37

30/37

30/37

Natural Gas (G20) Consumption

m3/h

2,41

3,05

3,83

LPG (G31) Consumption

m3/h

0,93

1,18

1,48

kg

31

34

38

Device Dimensions

mm

733x403x345

733x403x410

733x403x445

Weight (Packaged)

kg

34,5

37,5

41,5

mm

470x840x420

470x840x490

470x840x520

m

10

10

10

Weight & Dimensions

Weight (Net)

Box Dimensions

ErP Values

Max. Flue Length (60/100 mm) Seasonal local heating energy efficiency class

A

Water heating energy efficiency class

A

Seasonal local heating energy efficiency class (ηs)

%

Water heating energy efficiency class (ηwh)

%

91 87

85

24,30,38 kW

PREMIX Condensation Technology

Thermo Regulation

Premix Combustion

Energy Saving

Double Exchanger

Energy Saving

Made in Turkey

Comfort Mode

Eco-Friendly

Cascade System

Frequency Converter Pump


AIRFEL SAFE COMBI

1-Automatic air purger 2-Safety valve 3-Three-way valve anti-blockage system 4-Anti-overheating function 5-Automatic by-pass system 6-Pump anti-blockage system 7-Flue gas safety system 8-Ionization flame control 9-Drain stopcock 10-Anti-freeze function 11-Operation without water safety system 12-IPx5D electrical protection system 13-Low-voltage safety system

www.airfel.com.tr • 444 999 0


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.