C_Oxygen_Systems_Vehicular_Equipment_EN_0710_01

Page 1

C1

Oxygen Systems and Vehicular Equipment

Oxygen Systems and Vehicular Equipment Ensure a reliable supply of oxygen during transport.


Oxygen Systems and Vehicular Equipment

Whether patients are being treated with stationary or

vehicular facilities, cylinder brackets, fittings for pressure

mobile ventilation or inhalation, the oxygen dosage has to

reducers and cylinders, and accessories such as hoses, oxy-

be safe and effective at all times. Medical personnel there-

gen administrators and oxygen cannula. A reliable oxygen

fore need a completely dependable supply of oxygen. In

supply is thus ensured for mobile use when patients need

addition to the proven OXYWAY pressure reducers and

prolonged treatment at the scene of an emergency or

flow regulators, users can count on Weinmann‘s entire

during transport.

product line of oxygen cylinders for delivery systems and

C2


C3

Oxygen Systems and Vehicular Equipment

OXYWAY

Pressure reducer and flow regulator You can rely on the accuracy of OXYWAY pressure reducers and flow regulators. For only the properly dosed supply of oxygen can achieve the desired effect in the ventilation of your patients. Our OXYWAY pressure reducers and flow regulators, which we offer in several variants, can be used in many different ways in

the practice of oxygen and emergency medicine. All are available with up to two oxygen outlets (see page C4): flow outlet and pressure outlet. The former is used to supply oxygen directly to the patient while the latter guarantees a safe supply of oxygen delivered via a ventilator and oxygen administrator. 1 2

Flow outlet UNF 9/16“ Pressure outlet G 3/8“

and OXYWAY Fast II

or OXYWAY Fix

OXYWAY Fine

OXYWAY Fast I

OXYWAY Click

OXYWAY Fix

OXYWAY Fine

OXYWAY Fast

for permanently set oxygen flow of 4 l/min or 120 l/min for MEDUMAT-ventilators

for infinitely adjustable oxygen flow of 0.5–3 / 1.5–8 / 3–15 l/min with contents and flow gauge

for infinitely adjustable oxy- for flow dosage via a central gen flow dosage in levels 1 /  gas system in rescue services 2 / 3 / 4 / 5 / 6 / 9 / 12 / 15 l/min or and hospitals 0.5 / 1 / 1.5 / 2 / 2.5 / 3 / 4 / 5 / 6 l/min

OXYWAY Click

Features: Greatest level of operating safety with ultrasonic-tested highpressure housing and dual sinter filter „Made in Germany“ quality by Weinmann – with more than 40 years of experience in the manufacture of pressure reducers

Country-specific threads for pressurized connections (e.g., PIN, Bullnose, DIN) Range of connection bolt lengths (15-140 mm) available; high-pressure connectors mounted left or right as required Variability on device outlet (straight or angled connection nozzles, disposable or reusable humidifiers, flow meters, suction injector, administrators, country-specific standard couplings)

Observance of all relevant safety standards and norms Flow levels that are easy to set and check Low maintenance: The interim maintenance after two years can be done by the user.

Only with OXYWAY Fast and OXYWAY Click: flow setting can be read from both sides

Connections for pressure reducers and oxygen cylinders Because international standards differ, some countries require different connections for pressure reducers and oxygen cylinders. You can acquire from us the commercially available international standard connections (see below) and customized connection variants.

NGO

G 3/4“

W 21,8/21,7“

G 5/8“ 90° Bullnose

Please go to www.weinmann.de to read all technical data in product data sheets or instructions for use.

G 5/8“ 72° Bullnose

G 5/8“ 60° Bullnose

PIN-Index


Oxygen Systems and Vehicular Equipment

OXYWAY

Order number

Outlet UNF 9/16“

Fix I

30051

Fix III

Gauge

- 1x UNF 9/16“ - 4 l/min - side

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

30301

- 1x G 3/8“ - 120 l/min - bottom

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fix III

30421

- 1x quick coupling as per DIN 13260 - 120 l/min - bottom

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 50 mm - right

Fine I

30501

- 1x UNF 9/16“ - infinitely adjustable - 3 – 15 l/min - bottom

Contents gauge + flow gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fine II

30701

- 1x UNF 9/16“ - infinitely adjustable - 1,5 – 8 l/min - bottom

Contents gauge + flow gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fine III

WM 30751

- 1x UNF 9/16“ - infinitely adjustable - 0,5 – 3 l/min - bottom

Contents gauge + flow gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fast I

WM 30801

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fast II

WM 308512)

- 1x G 3/8“ - 90 l/min - bottom

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fast II

WM 308412)

- 1x quick coupling as per DIN 13260 - 90 l/min - bottom

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Fast II High Flow

WM 31891

- 1x G 3/8“ - free flow: about 190 l/min - bottom

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - left

Fast III

WM 30601

- 1x UNF 9/16“ - dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min - bottom - 1x UNF 9/16“ - dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min - bottom - 1x UNF 9/16“ - dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min - bottom - 1x UNF 9/16“ - dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min - top - 1x UNF 9/16“ - dosage settings lock into place at: 0.5/1/1.5/2/2.5/3/4/5/6 l/min - bottom 1x UNF 9/16“ - dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min - bottom 1x UNF 9/16“ - dosage settings lock into place at: 1/2/3/4/5/6/9/12/15 l/min - bottom

Contents gauge

G ¾“ (DE, CH, IL, AT)

- 30 mm - right

Plug complies with DIN 13260 for central gas system

AGA plug for central – gas system

Click WM 31040 Flow dosage

2)

Connection bolt length and position

Pressure outlet

Click WM 31030 Flow dosage

1)

Country-specific inlet connections)

Ordering info: final digit of number refers to connector type, e.g., WM 30305 = NGO, CGA 540 WM 30301 = G ¾“ WM 30306 = PIN Index WM 30302 = G 5/8“, 60° Bullnose WM 30307 = G 5/8, 90° Bullnose WM 30303 = G 5/8“, 72° Bullnose WM 30304 = W21,8/ 21,7 NOTE: WM 30851 and 30841 are not to be used with MEDUMAT Variable, MEDUMAT Control, MEDUMAT Compact and MEDUMAT Elektronik

(option: right or left), connection bolt length from 15 mm to 140 mm available)

Please note that the connection nozzles for all pressure reducers have to be ordered separately. Please ask our Customer Service for advice. NOTE: other country-specific connectors are available upon request

C4


C5

Oxygen Systems and Vehicular Equipment

Accessories 1

3

2

WM 31122

5

WM 31130

WM 31140

6

WM 1470

WM 22319

WM 22345

WM 1415

8

7

WM 1475

WM 22252

WM 2057

12

11

10

9

4

WM 22296

WM 22929

Accessories Connection nozzles UNF 9/16“ 1 Straight nozzle WM 31122 Ø 6 mm, with swivel nut UNF 9/16“, female threads (chrome-plated) and seal 90° Angled nozzle WM 31130 Ø 6 mm, with swivel nut UNF 9/16“ female threads (chrome-plated) and seal 2

90° Angled nozzle WM 31140 Ø 6 mm, with wing nut UNF 9/16“ female threads (chrome-plated) and seal 3

hose connection nozzle G 3/8“ Straight nozzle WM 1415 (NATO Stock Number 4730-12-368-4912) Ø 6,7 mm, with swivel nut G 3/8“ female threads (chrome-plated) and seal , suitable for hoses Ø 6 mm interior diameter (WM 1411) 4

5

Straight nozzle WM 1470 Ø 5,2 mm, with swivel nut(chrome-plated) G 3/8“ female threads and seal, suitable for hoses Ø 5 mm interior diameter (WM 2081)

Please go to www.weinmann.de to read all technical data in product data sheets or instructions for use.

6

90° Angled nozzle WM 22319 Ø 5,2 mm, with swivel nut (chrome-plated) G 3/8“ female threads and seal

7

90° Angled nozzle WM 1475 Ø 5,2 mm, with wing nut (chrome-plated) G 3/8“ female threads and seal

Central gas supply connector for oxygen 8 Angled connector complies with DIN 13260 WM 2057 9

Angled connector, AGA WM 22345

10 Straight

connector, bayonet (AFNOR) WM 22252 11 Straight connector, bayonet (AFNOR) WM 22296

Angled connector 45° complies with British Standard 5682 WM 28627 (not shown)

12 SIS-screw

connector, complies with AS 2896 WM 22929 for central gas system, complies with Australian norm


Oxygen Systems and Vehicular Equipment

1

3

2

WM 3799

6

WM 3910

4

WM 1289

WM 8220

8

7

5

9

WM 3949

WM 1231 WM 1485

WM 1412

WM 22584

Additional accessories (e.g., administrators and adapters) 1

2

3

T-shaped distributor WM 3910 (NATO Stock Number 4730-12-323-8076) with swivel nut G 3/8“ female threads, G 3/8“ male threads and oxygen quick coupling (Walther) T-shaped distributor WM 1289 (NATO Stock Number 4730-12-368-6643) with wing nut G 3/8“ female threads and 2x G 3/8“ male threads

4

T-shaped distributor with check valve WM 8220 with swivel nut G 3/8“ female threads, G 3/8“ male threads and oxygen quick coupling (Walther)

5

Adapter for connector, complies with DIN 13260 WM 3949 with swivel nut G 3/8“ female threads, 20 cm hose and hose coupling, complies with DIN 13260

Connector for oxygen quick coupling WM 3799 (NATO Stock Number 6515-12-343-6142) angled 90° (accessory required for assembly: WM 2078) - oxygen cap (Walther), nominal size 4 mm, - hose connection Ø 6 mm

6

Adapter WM 1485 with swivel nut G 3/8“ female threads and oxygen quick coupling (Walther)

7

Screw nozzle WM 1412 with G 3/8“ male threads and hose connector Ø 4,4 mm

8

NIST Adapter WM 22584 with G 3/8“ female threads and NIST male threads for MEDUMATs, MODULs and OXYWAY pressure reducers

Screw-type blank cap with G 3/8“ WM 1231 with G 3/8“ female threads to seal connectors with G 3/8“ male threads (such as MEDUMAT Transport) 9

C6


C7

Oxygen Systems and Vehicular Equipment

2

1

WM 1929

WM 1925

3

4

WM 22210

WM 1921

WM 1429

WM 22200

MODUL Oxygen

Nasal Cannula

WM 22200

1

Infinitely adjustable oxygen inhalation from 0 to 15 liters/min, with O2 quick coupling (Walther) and straight connection nozzle for inhalation hose.

MODUL Combi WM 22210 Suction and oxygen inhalation from 0 to 15 liters/min, suction fixed at –0,5 bar, with O2 quick coupling (Walther) and connection socket for inhalation hose and test pressure gauge

WM 15341 WM 15342 WM 15343

Nasal cannula for children, double lumen with 2.1-meter connection hose

WM 1921

– Set I: 20 nasal cannula (20 x WM 1921) – Set II: 40 nasal cannula (40 x WM 1921) – Set III: 100 nasal cannula (100 x WM 1921)

WM 15344 WM 15345 WM 15346

2

Nasal cannula for adults, double lumen with 1.5-meter connection hose

– Set I: 20 nasal cannula (20 x WM 1925) – Set II: 40 nasal cannula (40 x WM 1925) – Set III: 100 nasal cannula (100 x WM 1925)

WM 1925 WM 15251 WM 15252 WM 15222

Nasal cannula for adults, double lumen with earpiece and 1.5-meter connection hose (not shown) WM 1929

Detailed descriptions of MODUL Combi and MODUL Oxygen are on Page A15. They can be installed in an emergency vehicle and integrated on a LIFE-BASE portable system (see Section B).

WM 1920

– Set I: 20 nasal cannula (20 x WM 1920) – Set II: 40 nasal cannula (40 x WM 1920) – Set III: 100 nasal cannula (100 x WM 1920)

3

Note

Nasal cannula for babies, double lumen with 2.1-meter connection hose

– Set I: 20 nasal cannula (20 x WM 1929) – Set II: 40 nasal cannula (40 x WM 1929) – Set III: 100 nasal cannula (100 x WM 1929)

WM 15220 WM 15225 WM 15221

Inhalation masks 4

Oxygen inhalation masks, plastic with connection hose

– Set I: 6 oxygen inhalation masks (6 x WM 1429) – Set II: 12 oxygen inhalation masks (12 x WM 1429)

WM 1429 WM 15210 WM 15215


Oxygen Systems and Vehicular Equipment

WM 22303

Pressure hose Hose of medical-grade PVC, white, 10 bar, internal diameter 5 mm, wall thickness 3 mm (WM 2081). Other hose lengths are available upon request. Hose connector A

Hose connector B

Length

Order Number

Swivel nut G 3/8“ female threads with angled connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle

35 cm

WM 22315

Swivel nut G 3/8“ female threads with straight connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle

45 cm

WM 22320

Swivel nut G 3/8“ female threads with angled connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle

47 cm

WM 22367

Swivel nut G 3/8“ female threads with straight connection nozzle

Swivel nut G 3/8“ female threads with straight connection nozzle

1m

WM 22301

Swivel nut G 3/8“ female threads with straight connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle

1m

WM 22302

Swivel nut G 3/8“ female threads with angled connection nozzle

Swivel nut G 3/8“ female threads with angled connection nozzle

1m

WM 22305

Swivel nut G 3/8“ female threads with straight connection nozzle

Screw nozzle with male threads G 3/8

1m

WM 22316

Walther male connector

Swivel nut G 3/8“ female threads with straight connection nozzle

3m

WM 22306

Walther male connector

Swivel nut G 3/8“ female threads with angled connection nozzle

3m

WM 22307

O2 male connector (DIN 13260-compliant) for central gas supply outlet

Walther male connector

3m

WM 22303

O2 male connector (DIN 13260-compliant) for central gas supply outlet

Swivel nut G 3/8“ female threads with angled connection nozzle

3m

WM 22312

O2 male connector (DIN 13260-compliant) for central gas supply outlet

Swivel nut G 3/8“ female threads with straight connection nozzle

3m

WM 22308

O2 male connector (bayonet AFNOR) for central gas supply outlet

Walther male connector

3m

WM 22304

O2 male connector (bayonet AFNOR) for central gas supply outlet

Swivel nut G 3/8“ female threads with straight connection nozzle

3m

WM 22311

O2 male connector (bayonet AFNOR) for central gas supply outlet

Swivel nut G 3/8“ female threads with angled connection nozzle

3m

WM 22314

O2 male connector (bayonet AFNOR) for central gas supply outlet

O2 male connector (bayonet AFNOR) for central gas supply outlet, straight

3m

WM 22371

O2 male connector (AGA) for central gas supply outlet

Swivel nut G 3/8“ female threads with straight connection nozzle

3m

WM 22309

C8


C9

Oxygen Systems and Vehicular Equipment

Oxygen administrators Oxygen administrators deliver a flow of oxygen to patient(s). The functions inhalation, ventilation and suction can be set up

independent of each other but can be supplied by a single gas source.

1

5 WM 3720

WM 3740

2

6 WM 3820

WM 3743

7

3

WM 3750

WM 3730

4

8 WM 3832

WM 3880

Accessories Oxygen administrator with two outlets WM 3720 Inlet: 1 x G 3/8“ wing nut, top Outlet: 2 x G 3/8“ male thread, free

Oxygen administrator with four outlets WM 3740 Inlet: 1 x G 3/8“ wing nut, top Outlet: 4 x G 3/8“ male thread, free

WM 3714 (not shown) reverse screw-on type Inlet: 1 x G 3/8“ male thread, top Outlet: 2 x G 3/8“ male thread, free

Oxygen administrator with four outlets WM 3743 Inlet: 1 x G 3/8“ male thread, top Outlet: 3 x G 3/8“ male thread, free 1 x G 3/8“ male thread, secretion, 13 l/min

1

Oxygen administrator with two outlets WM 3820 Inlet: 1 x G 3/8“ wing nut, left Outlet: 1 x G 3/8“ male thread, secretion, 13 l/min 1 x UNF 9/16“ male thread, 10 l/min 2

Oxygen administrator with three outlets WM 3730 Inlet: 1 x G 3/8“ wing nut, top Outlet: 3 x G 3/8“ male thread, free 3

WM 3834 (not shown) Inlet: 1 x G 3/8“ male thread, top Outlet: 3 x UNF 9/16“ male thread, 10 l/min, incl. 3 x WM 31130 angled connector

Oxygen administrator with three outlets WM 3832 Inlet: 1 x G 3/8“ wing nut, left Outlet: 1 x G 3/8“ male thread, secretion, 13 l/min 2 x UNF 9/16“ male thread, 10 l/min 4

Please go to www.weinmann.de to read all technical data in product data sheets or instructions for use.

5

6

Oxygen administrator with four outlets WM 3750 Inlet: 1 x G 3/8“ wing nut, left Outlet: 3 x UNF 9/16“ male thread, 10 l/min 1 x G 3/8“ male thread, secretion, 13 l/min 7

Oxygen administrator with four dosage setting stops for outlets WM 3880 Outlet: 4 x UNF 9/16“ male thread, 0-15 l/min, dosage clicks into place, incl. 4 x WM 31122 connection nozzle 8

Inlet / Outlet: 3 x G 3/8“ male thread, top, bottom, right

Cut-off valve Cut-off valve with two outlets WM 3737 Inlet: 1 x G 3/8“ wing nut, left Outlet: 1 x G 3/8“ male thread, secretion, 13 l/min 1 x G 3/8“ male thread, free, closed with cap 9

9


Oxygen Systems and Vehicular Equipment

1

2

3

4

5

WM 1818

WM 1814 WM 1822 WM 1805

WM 1885

WM 1825

Cylinder bracket

Oxygen cylinder

WM 1885

Empty, with G ¾“ connection thread*

Set of two for stationary O2 facilities in buildings or vehicles for two-liter and three-liter oxygen cylinders, Ø 100 mm (complies with Norm EN 1789) WM 1887 (not shown) Set of two for stationary O2 facilities in buildings or vehicles for 2.5-liter oxygen cylinder, Ø 115 mm (complies with Norm EN 1789) WM 1889 (not shown) (NATO Stock Number 2590-12-368-6436) Set of two for stationary O2 facilities in buildings or vehicles for five-liter, 10-liter and 11-liter oxygen cylinders, Ø 140 mm (complies with Norm EN 1789)

1

WM 1818-02

0.8-liter x 200 bar, capacity = 160 liter O2 2

3

4

WM 1814-02 Lightweight oxygen cylinder of aluminum, 2-liter x 200 bar, capacity = 400 liter O2 WM 1822-02 2-liter x 200 bar, capacity = 400 liter O2 WM 1805-02 (NATO Stock Number 6505-12-382-2129)

5-liter x 200 bar, capacity = 1000 Liter O2 5

WM 1825-02 (NATO Stock Number 6505-12-321-1981)

10-liter x 200 bar, capacity = 2000 liter O2, with safety cap and collar, integrated base WM 1830-02 (not shown) similar to WM 1825, but with 11 l x 200 bar, capacity = 2200 liter O2

* Different international connection threads are available upon request.

C10


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.