gloriakatologue

Page 1

fire safety catalogue extinguishers and trolley units ancilliary items brigade equipment detection and alarms


The Gloria brand is recognised by the independent fire trade as a product of renowned quality. Fully approved to relevant British and European standards with a proven track record of durability and reliability – the Gloria range offers customers true peace of mind. With both stored pressure and cartridge operated extinguishers available, to cover practically any type of fire risk, you needn’t waste time searching for a complete extinguisher range – you’ve just found it. Items in this catalogue are available at the time of publication but we reserve the right to change our product range and/or product specification anytime.

1 SECTION 1 Fire Power Extinguishers Trolley Units

extinguishers extinguishers and trolley units ancilliary items brigade equipment detection and alarms

2-8 9-10

2-10


E x t i n gu i s h e r s

Water Extinguishers Portable Fire Extinguishers4Section 1

Stored Pressure/Cartridge Operated

All Water General n Easy squeeze grip operation n Fully refillable n Controlled discharge n Internal polyethylene lining n Wall mount bracket included n Strong protective base n Robust discharge hose n Jet nozzle For Stored Pressure (Water additive only) n Weight and ease of use advantages n Effective spray application n Spray nozzle n Have passed the 35kv conductivity discharge test

Specifications Model: Item number:

SP Water

SP Water Additive

SP Water Additive

CO Water

W9DN

W3DX

W6DX

WI9DB

4903/207

4918/207

4919/207

4904/207

Capacity

9ltr

3ltr

6ltr

9ltr

Fire rating

13A

13A

21A

13A

Height (mm)

620

435

533

568

Cylinder diameter (mm)

200

160

180

183

Overall width (mm)

280

275

230

216

Filled weight (kg)

14.3

4.4

12.6

8

Range of throw (m)

7-8

4

4

4-6

Duration of discharge (secs)

60

30

60

45

Working pressure (bar)

7

7

7

14

Temperature range (째c)

0 to +60

+5 to +60

+5 to +60

0 to +60

BS EN3 approved

Y

Y

Y

Y

Med approved

Y

Y


E x t i ngui s he r s

Foam Extinguishers Portable Fire Extinguishers4Section 1

Stored Pressure/Cartridge Operated

For Shrouded Head Foam (Below)

All Foam General n Easy squeeze grip operation

n Unique push button operation

n Fully refilable

n Wire transport bracket and securing strap included

n Controlled discharge n Internal polyethylene lining n Wall mount bracket included n Strong protective base* n Robust discharge hose n Spray nozzle n Have passed the 35kv conductivity discharge test *Excludes 2ltr models

SP Foam

Specifications Model: Item number: Type Capacity Fire rating Height (mm)

SD2LW AFFF Foam Spray S/P

AFFF 4260/207 AFFF Foam 2ltr Foam Spray Spray 5A 55B S/P S/P 365

SP Foam

SP Foam

SP Foam

CO Foam

CO Foam

SP Foam (shrouded head)

S3DLWB

S6DLWB

S9DLWB

SI6DB

SI9DB

S2LW

4257/207 AFFF Foam 3ltr Spray 8A 89B S/P 485

4251/207

4252/207

4253/207

4254/207

4256/207

6ltr

9ltr

6ltr

9ltr

2ltr

13A 183B

21A 183B

13A 233B

21A 233B

5A 70B

455

610

610

623

365

Cylinder diameter (mm)

108

165

170

200

160

200

110

Overall width (mm)

145

270

260

260

270

285

152

Filled weight (kg)

3.5

5.9

10.5

14.9

7

8

3.5

Range of throw (m)

2.5

4

4-6

4-6

4-6

4-6

2

Duration of discharge (secs)

22

14

36

53

26

49

20

Working pressure (bar)

15

7

7

7

14

8

15

Temperature range (째c)

0 to +60

+5 to +60

0 to +60

0 to +60

0 to +60

0 to +60

0 to +60

Y

Y

Y

Y

Y

Y

Y

Y

Y

BS EN3 approved Med approved

Y


E x t i n gu i s h e r s

Powder Extinguishers Powder Extinguishers4Section 1

Stored Pressure/Cartridge Operated

All Powder General n Easy squeeze grip operation n Fully refillable n Controlled discharge n Multi-purpose application n 1 & 2kg C/W wire transport bracket and securing strap n 6,9 & 12kg C/W wall mounting bracket n Strong protective base* n Robust discharge hose (4,6,9 & 12kg) *Excludes 1kg and 2kg models

Specifications Model: Item number: Capacity

SP Powder

SP Powder

SP Powder

SP Powder

SP Powder

SP Powder

PD1GA

PD2G

PD4GA

PD6GA

PD9GA

PD12GA

4358/207

4352/207

4354/207

4356/207

4359/207

4366/207

1kg

2kg

4kg

6kg

9kg

12kg

5A 34B

13A 89B

21A 113B

27A 183B

43A 233B

55A 233B

Height (mm)

280

408

415

505

605

590

Cylinder diameter (mm)

95

108

160

160

200

210

Overall width (mm)

135

170

310

285

305

265

Filled weight (kg)

1.5

3.2

6.7

9.1

13.6

17.3

Fire rating

Range of throw (m)

4

4

6

6

7

7

Duration of discharge (secs)

8

10

12

16

16

22

Working pressure (bar)

15

15

15

15

15

15

Temperature range (째c)

-30 to +60

-30 to +60

-30 to +60

-30 to +60

-30 to +60

-30 to +60

Y

Y

Y

Y

Y

Y

Y

Y

BS EN3 approved Med approved

Y

Y** **For Lifeboat use only


E x t i ngui s he r s

Powder Extinguishers Water Extinguishers4Section 1

Stored Pressure/Cartridge Operated

For Shrouded Head Powder

Cartridge Operated Powder

n Unique push button operation

n Easy squeeze grip operation

n Compact with easy operation

n Fully refilable

n Carrying handle

n Controlled discharge

n Integrated, protected, pressure gauge

n Multi-purpose application

n Fully refillable

n Heavy duty brass head assembly

n Controlled discharge

n C/W wall mount bracket

n C/W bracket and securing strap

n Strong protective base n Robust discharge hose

Specifications Model: Item number: Capacity

SP Powder (Shrouded Head)

SP Powder (Shrouded Head)

CO Powder

CO Powder

P1GM

P2GM

PEP6GA

PEP12GA

4351/207

4362/207

4360/207

4368/207

1kg

2kg

6kg

12kg

8A 34B

13A 89B

27A 144B

43A 233B

Height (mm)

267

315

540

640

Cylinder diameter (mm)

90

110

160

200

Overall width (mm)

109

145

270

320

Filled weight (kg)

1.5

3.5

10.1

19

Range of throw (m)

4

4

6

7

Duration of discharge (secs)

8

10

14

21

Fire rating

Working pressure (bar)

15

15

Temperature range (째c)

-30 to +60

-30 to +60

-20 to +60

-20 to +60

Y

Y

Y

Y

Y**

Y**

Y

Y

BS EN3 approved Med approved

**For Lifeboat use only


E x t i n gu i s h e r s

CO2 Extinguishers co2 Extinguishers4Section 1

Stored Pressure

n Easy squeeze grip operation n Fully refilable n Controlled discharge n Wall mount bracket included n C20GH offers 55B rating & safe to handle horn n Lightweight aluminium cylinder

Specifications Model: Item number:

SP CO2

SP CO2

SP CO2

C20G

C20GH

C50G

4705/207

4706/207

4707/207

Capacity

2kg

2kg

5kg

Fire rating

34B

55B

70B

Height (mm)

490

490

750

Cylinder diameter (mm)

117

117

152

Overall width (mm)

180

180

310

Filled weight (kg)

4.93

4.93

11.59

Range of throw (m)

4

4

4

Duration of discharge (secs)

8

9

14

Working pressure (bar)

56

56

56

Temperature range (째c)

-30 to +60

-30 to +60

-30 to +60

Y

Y

Y

BS EN3 approved Med approved

Y


E x t i ngui s he r s

F-Class

Cartridge Operated

Stored Pressure

n Easy squeeze grip operation

n Easy squeeze grip operation

n Fully refilable

n Fully refilable

n Controlled discharge

n Controlled discharge

n Lance applicator

n Lance applicator

n Specifically designed for use on metal fires

n Specifically designed for use on cooking oil fires

n Wall mount bracket included

n Solution reacts with oil to prevent re-ignition

n Strong protective base

n Wall mount bracket included

Specifications Model: Item number: Capacity

CO Powder D-Class

D-Class & F-Class Extinguishers4Section 1

D-Class Powder Extinguishers

CO F-Class

P12M

W6DRC

4367/207

4500/207

12kg

6ltr

D

13A 75F

Height (mm)

685

533

Cylinder diameter (mm)

218

180

Overall width (mm)

306

242

Filled weight (kg)

21

11.8

Fire rating

Range of throw (m)

7

4

Duration of discharge (secs)

20

43

Working pressure (bar)

15

7

Temperature range (째c)

-20 to +60

0 to +60 Y

BS EN3 approved Med approved

Y


E x t i n gu i s h e r s

Polished Extinguisher

Stored Pressure

Stored Pressure

Extinguishers4Section 1

Stainless Steel Extinguishers

n Ideal for environments where hygiene is paramount when considering architecture n Highly polished surface finish n Corrosion resistant construction n Simple “seize and squeeze” operation n Controllable discharge assures efficient use of content and minimises clean-up n All extinguishers are re-chargeable

Specifications Model: Item number:

SP Water

SP Water

SP Foam

SP Foam

SP CO2

FPW6S

FPW9S

FPF6S

FPF9S

C20G

4905/207

4906/207

4217/207

4218/207

4705/06

Capacity

6ltr

9ltr

6ltr

9ltr

2kg

Fire rating

13A

21A

13A 144B

21A 183B

34B

Height (mm)

500

640

500

640

490

Cylinder diameter (mm)

180

180

180

180

117

Overall width (mm)

300

300

300

300

180

Filled weight (kg)

8.63

12.22

8.63

12.22

4.93

Range of throw (m)

>4

>4

>4

>4

4

Duration of discharge (secs)

40

60

25

40

8

Working pressure (bar)

15 bar

15 bar

15 bar

15 bar

56

Temperature range (°c)

0 to 60

0 to 60

0 to 60

0 to 60

-30 to +60

BS EN3 approved Med approved


E x t i ngui s he r s

Powder/Foam Trolley Units Trolley Extinguishers4Section 1

Stored Pressure/Catridge Operated

n Mobile & stable

n Weather-resistant polyester paint finish

n Solid tyred steel wheels

n Safety valve

n Space-saving design

n Easy to maintain

n Controlled discharge n Single operator required n CE marked n Precision built mechanical pressure gauge for accurate pressure reading n High grade brass head ensures reliability & optimises efficiency

Specifications Model: Item number:

SP Powder

SP Powder

CO Powder

CO Foam

PD25

PD50

P50G

LW50

UTR00008

UTR00009

UTR00007 / UTR00006

UTR00005

Capacity

25kg

50kg

50kg

50ltr

Height (mm)

1004

1130

1070

595

Cylinder diameter (mm)

250

300

495

660

Overall width (mm)

380

450

615

103

Filled weight (kg)

45

82

100

12

10-12

65

Range of throw (m) Duration of discharge (secs) Working pressure (bar) Temperature range (째c)

25

50

50

18

14

0 to +50

-20 to +60

C/W 5m hose

Available with 5 & 10m hose BS EN3 approved Med approved


E x t i n gu i s h e r s

10

CO2 Trolley Units Trolley Extinguishers4Section 1

Stored Pressure

n Approval to DIN EN 3 n Cylindrical snow horn for effective fire fighting n Mobile & stable n Controlled discharge n Additional handles on snow horn for optimal performance

Specifications Model: Item number:

SP CO2

SP CO2

SP CO2

SP CO2

KS10

KS20

KS30

KS50

UTR00000

UTR00001

UTR0003 / UTR0002

UTR0004

Capacity

10kg

20kg

30kg

50kg

Fire rating

113B

144B

B

5 x 144B

Height (mm)

1040

1210

1520

1590

Cylinder diameter (mm)

480

480

520

540

Overall width (mm)

480

480

1540

1100

Filled weight (kg)

45

72.4

110

150

Range of throw (m)

4-5

5.5

4-5

4-5

Duration of discharge (secs)

15

20

78

45

Working pressure (bar)

58

58

58

56

Temperature range (째c)

-20 to +60

-20 to +60

-20 to +60

-20 to +60

C/W 6m hose

C/W 6m hose

Available with 6 & 10m hose

C/W 6m hose

BS EN3 approved Med approved


Kite KM mar BS 506 k No 81/ EN 1 560 023 869 38 :199

FIR BLAE N

2 section 2 Fire Blankets Cabinets Covers Stands Fire Points Panic Bolts, Key Box and Latches Dorgard Escape Ladders Alarm Bell Fire Buckets Domestic Extinguishers First Aid Kits

12 12-13 14 14 15 16-17 17 17 17 18 18 18

P RE ULL L E A TA SE BS T BLA O NK ET

ancillary items extinguishers and hose reels ancilliary items brigade equipment detection and alarms

Pu an ll tab do sd utw ow ard n s Co v ma er b ter urn ial co ing mp Sw let ely lea itch o ve f co f hea ve red t and un til c oo

11-18


Fire Blankets and Cabinets4Section 2

12

A N C I L L A RY I T E M S

BLANKETS

CABINETS

Fire Blankets

Hinged Door Cabinets

a

b

c

A range of top quality slim fire blankets. Suitable for smothering and extinguishing fires in homes, kitchens, schools, hospitals, laboratories, offices and factories.

A choice of single and double hinged cabinets made from tough new ABS and PE plastics. Traditional GRP cabinets are also still available if preferred.

Fire blankets offer a number of advantages over other blankets commonly available:

ABS/Polyurethane Cabinets

■ 12 months warranty. ■ 200 gram cloth ensures flexibility and drapability. ■ The suppleness and strength of the blanket. offers user confidence as it is well insulated, yet easily drapes over the fire. ■ Full traceability through individual blanket batch numbering.

■ E nvironmentally friendly ­– manufactured from recyclable or recycled materials. ■ Consistent, smooth finish (internal and external). ■ Will not chip or crack. ■ Easily transportable. ■ Innovative design and manufacturing process. ■ Higher impact strength than GRP.

■ Flush end caps for easy cleaning.

■ Hygienic – suitable for food preparation and clinical environments (unlike GRP).

■ Hinged cap with security seal option to avoids blankets being tampered with.

■ Suitable for wall or post mounting.

■ Production is made under a quality management system ISO 9001:2000 ensuring strict quality control procedures are met.

GRP Cabinets

■ All blankets comply with BS EN 1869:1997 and are kitemarked. Description 1.0m x 1.0m slim pack – red 1.2m x 1.2m slim pack – red 1.8m x 1.2m slim pack – red

Part Number 81/02332 81/02338 81/02344

■ Toggle clamp closure mechanism.

■ Specially designed base to give safe, two-handed removal of extinguisher. ■ Polymide wing closure. ■ Corrosion resistant construction. ■ High-gloss finish. ■ Suitable for wall or post mounting.

Ref Description Part Number A Single cabinet – ABS 81/00791 Double cabinet – ABS 81/00861 B Single cabinet – GRP 46/54653 Double cabinet – GRP 46/54654 C Single – Clear front 81/02811 C Double – Clear front 81/02812 All the above are not suitable for 5kg C02 Extinguishers A Single cabinet for 5kg CO2 Ext – ABS 81/02239


a nc i llary i tem s

13

Hose Reel Rgid Cover

A choice of vehicle extinguisher cabinets made from polyethylene.

Manufactured in red glass-reinforced polyester resin (GRP).

Polyethylene Cabinet

Suitable for rear-mounted fixed and swinging hose reels (fixings not supplied).

■ Shatterproof and lightweight design.

Lift-off-front for easy access to hose reel.

■ Incorporates 4 x M8 encapsulated T nuts.

Designed for use in harsh environmental conditions.

H570mm x W600mm x D260mm.

Cabinets4Section 2

Vehicle Extinguisher Cabinet

Description Part Number * Vehicle extinguisher cabinet for 9kg Extinguisher – H750 x W300 x D270mm 81/00870 * Vehicle extinguisher cabinet for 81/00792 6kg Extinguisher – H650 xW240 x D240mm * These do not include a fixing kit – please order separately Fixing kit for vehicle cabinet – 30/60 degree angle mounting Fixing kit for vehicle cabinet – horizontal mounting

Description Hose Reel Rigid Cover

Part Number 81/00247

Hose Cradle

81/02053 81/02327

■ Manufactured in red glass-reinforced polyester resin. ■ Can be mounted in cabinets or to walls. (fixings not supplied) Description Hose Cradle

Part Number 46/54225


A N C I L L A RY I T E M S

14

STANDS

Extinguisher Covers

Extinguisher Stands - GRP

■ Manufactured from PVC.

A prestige range of fire extinguisher stands.

■ Clear viewing port.

■ High-gloss finish.

■ Ideal protection in harsh environments.

■ Single and double versions.

Covers & Stands4Section 2

COVERS

■ Designed for rapid removal Description Red 20" x 11" extinguisher cover Red 24" x 11" extinguisher cover

Part Number 81/00107 81/00108

Hose Reel Cover

Extinguisher Stands - Moulded Plastic

■ Manufactured from strengthened PVC.

Description Single stand – red Double stand – red

■ Ideal protection in harsh environments. ■ Designed for rapid removal. Description Red hose reel flexible cover

Description Part Number Single stand – red 81/02405 Single stand – grey 81/02406 Double stand – red 81/02407 Double stand – grey 81/02408

Part Number 46/57354

Part Number 81/02743 81/02744


A NC I L L ARY I T E M S

15

Mobile Fire Points

Extinguisher Fire Points

Fire Points4Section 1

Double / Triple

■ Manufactured from plastic ABS. ■ Will not chip or crack.

A choice of mobile fire points, ideal for moving firefighting equipment close to the source of a fire.

■ Higher impact strength than GRP.

■ Chassis fabricated from mild steel square tube. ■ Epoxy polyester powder paint finish in red.

Description Single fire point Double fire point

Part Number 46/57357 46/57358

■ Nylon wheels with rubber tread for ease of movement. ■ Ideal for petrol station forecourts.

Description Part Number To hold two fire extinguishers and one fire bucket 81/00212 To hold three fire extinguishers and two fire buckets 46/57049 To hold two fire extinguishers, and a fire bucket, complete with bell 46/57815


16

A N C I L L A RY I T E M S

ESCAPE BOLTS, KEYS AND LATCHES

Key Box and Glasses

Escape & Fire Safety 4Section 2

Redlam Panic Bolts

Manufactured from cast aluminium, Redlam panic bolts are the economical solution to the problem of providing reliable security for internal emergency exits.

■ Manufactured from durable ABS plastic.

Mark I Designed for emergency exit single doors. Breaking the Ceramtube™ results in the bolt sliding back automatically and unlocking the door.

■ Spare glass for Mk II key box can also be supplied.

Mark II Designed for interconnecting emergency exit doors. Operates on one side of the door by breaking the Ceramtube™ and on the other side of the door by pushing the knob. Both versions are supplied complete with hammer and chain. Padlocks and ‘To open break tube’ signs are available separately. Use of an optional padlock prevents unauthorised removal of Ceramtube™ without breaking the tube itself. Ceramtube™ Replacement cartridges for both Mk I and Mk II Redlam panic bolts. Designed to produce no sharp edges when smashed. Packed in boxes of twenty.

■ Unique ‘snap fit’ design. ■ Mk I key box supplied complete with printed glass.

Ref A B

Description Mk I key box Hammer and chain Spare glass for Mk I key box Spare glass for Mk II key

Part Number 46/54280 39/51921 46/27218 46/57345

Panic Latch

Incorporates a robust rectangular section, steel cross arm with downward thrust action, giving added strength, ease of operation and an attractive appearance. ■ Manufactured primarily from Mazak Alloy to BS 1004A. ■ Finished in dark metallic grey. ■ Surface mounted. ■ Supplied with full fixing instructions.

Description Mk I Panic bolt Mk II Panic bolt Keeper plate (spare) Hammer and chain (spare) Ceramtube™ (box of 20) Padlock (anti-tamper)

Part Number 46/32207 46/32951 46/33070 39/51921 46/57050 46/54457

■ Can be converted for right or left. hand operation.

Description Panic latch

Part Number 46/57615


A NC I L L ARY I T E M S Single and Double Door Panic Latch/Bolt

17

Escape Ladders 15 and 25 feet ■ Suitable for two and three storey buildings. ■ Unique ‘tangle-free’ design. ■ Fully assembled. ■ Quickly attached to window for easy escape. ■ White coating to prevent corrosion. Description Escape ladder – 15 foot Escape ladder – 25 foot

■ Conforms to BS 5725 part 1. ■ Specified and approved by fire officers and local authorities.

Part Number 46/6355 46/6430

Rotary Hand Alarm Bell

■ Anti-thrust device prevents upward leverage of the bottom shoot, providing increased security. ■ Triple action device fitted to the top shoot keeps the shoots withdrawn when the door is open and automatically releases them when the door is closed. ■ Surface mounted – fixing instructions supplied. ■ Manufactured from cast iron with steel tubes, brass follower and extruded aluminium guides. ■ Finished in dark metallic grey. Description Single door panic latch/bolt Double door panic latch/bolt

Part Number 46/60145 46/61564

Acoustic Fire Door Release Device ■ Ideal for outside locations such as caravan sites ■ Bell sounds 60dB alarm up to 35 metres ■ Die-cast aluminium dome, powder coated red ■ Base plate die-cast aluminium ■ Pre-drilled flange for fast and easy mounting (fixings not included) ■ Weight 1.8 kg, overall diameter 280mm, depth 135mm Dorgard is an acoustically activated fire door release device. Dorgard can hold fire doors open in any position and release them automatically should a fire alarm sound. ■ Manufactured and tested in accordance with BS EN 1155. ■ Accepted by Chief Fire Officers Association (CFOA). ■ Endorsed by the National Care Homes Association. ■ Designed in line with the Disability Discrimination Act. Description Part Number Dorgard Auto release - black 81/02781 Other colours available on request, subject to lead times.

Description Rotary Hand Alarm Bell

Part Number 42/57030

Escape & Fire Safety 4Section 2

Steel escape ladders, intended for domestic use only.


A N C I L L A RY P R O D U C T S

18

Home/Car Guard Extinguishers

Metal and Plastic

Stored Pressure Multi-Purpose

■ Suitable for garage forecourt protection and clearing up spillages.

■ Ideal for the home, car, boat, caravan or garage.

■ Metal buckets are epoxy polyester powder painted in red.

■ Safe for most household fire types including electrical fires (not suitable for cooking fat fires).

■ ‘Fire’ label supplied loose with metal bucket.

■ High grade nickel plated brass valve assembly ensures reliability and optimizes efficiency whilst being protected from corrosion.

Safety Products4Section 2

Fire Buckets

■ Lids for both buckets are supplied separately. ■ Wall-mounting bracket suitable for metal and plastic buckets. Ref A B C D E

Description Metal flat bottom Metal lid for 3745/00 Plastic 2 gallon 'D' type Plastic lid for 3745/01 Wall mounting bracket

Part Number 3745/00 3747/00 3745/01 3747/01 3749/00

First Aid Kits

■ Now comes complete with wire bracket.

■ Coated steel levers built to withstand the hardest knocks. ■ 14 bar working pressure for maximum fire fighting performance gives greater application reach ensuring user safety. ■ Long drawn high grade steel body shell for optimum strength. ■ Polyester external coating adds extra protection to withstand extreme temperatures, dirty environments and UV degradation. ■ Precision built mechanical pressure gauge provides a very accurate indication of extinguisher’s pressure status. ■ Approved to the Pressure Equipment Directive. ■ CE marked and kitemarked.

A comprehensive range of first aid kits that are fully compliant with the Approved Code of Practice and the Health and Safety Executive. Description 1 to 10 persons 1 to 20 persons 1 to 50 persons

Part Number 81/02807 81/02808 81/02809

Type

Powder Powder 1kg 2kg

Fire rating Height (mm) Cylinder dia (mm) Overall width (mm) Filled weight (kg) Range of throw (m) Duration of discharge (secs) Working pressure (at 20˚C) Temperature range (˚C) BS EN3 approved Part number

8A 34B 13A 70B 335 385 78 112 118 132 2.0 3.42 >2 >2 min 6 min 9 14 bar 14 bar -20 to +60 -20 to +60 ✓ ✓ 81/02652 81/02694


3 SEction 3 Inlet Breechings

20

Inlet and Outlet Cabinets Outlet Valves Valve Ancill足aries Standpipes/Bars/Keys Underground Hydrants Blank Plugs Dividing Breeching Hoses and Couplings Branchpipes and Nozzles Reelfoam Units Foam

21 21 22 22 23 23 23 24 25 25 26

brigade equipment extinguishers and hose reels ancilliary items brigade equipment detection and alarms

19-26


B RI G A D E E Q U I P M E N T

20

Inlet Breechings

Dry Riser Mains Installation/Inlet Breechings4Section 3

Dry Rising Mains Installation Dry and wet rising mains are intended for use by the fire brigade or other trained personnel. They provide a readily available means of delivering considerable quantities of water to extinguish or to prevent the spread of fire. Dry risers are vertical mains fitted into staircase enclosures or other suitable positions, with outlet valves on each floor and inlets fitted at ground level to enable the fire brigade to connect to the water supply. Wet risers are pipes kept permanently charged with water either from a storage tank (via a booster pump) or direct from the town’s main water supply. Before installing dry or wet rising mains the exact requirements of the local fire brigade must be ascertained.

Complies with BS 5041 Part 3 Air Release Valve

Dry riser inlet breechings are normally fitted in glass-fronted cabinets on the outside walls of buildings and have either two or four inlet connections.

Landing Valve

They are used to feed water into the rising main through 21⁄2" fire hoses. A 100mm (4") rising main uses a two-way inlet breeching and a 150mm (6") main uses a four-way inlet breeching. Drain Valves to BS 5154 Normally fitted to inlet breechings but can be supplied separately.

Landing Valve

External Wall

Two-way Inlet Breechings 4" BSTD, 4" BSP parallel female or 100mm NP16 – can be mounted either horizontally or vertically. Air Release Valve - See page 22

Steel Cabinet with Glazed Door

Gate Valve

Landing Valve

Two-way Inlet Breaching

Ground Floor

25mm Drain Valve

Description Inlet breeching two way flanged 4” BSTD (4 Holes) Inlet breeching two way flanged 100mm (8 Holes) Inlet breeching two way screwed 4” BSP female Drain valve Blank cap and chain (drain valve) Rubber cap female

Part Number 46/54189 46/54903 46/54194 46/57363 46/57364 46/57365


B RI G A D E E Q U I P M E N T Inlet and Outlet Cabinets

Outlet Valves

A range of inlet and outlet cabinets built to comply with BS5041: Part 5.

Landing Valves Landing valves used on dry rising mains should normally be of the gate valve type, but globe pattern valves are occasionally used. They act as outlets from the rising main and are fitted in easily accessible positions on each floor above the first floor of a building and sometimes in deep basement areas.

n Designed to house inlet breechings and landing valves. n Georgian wired glass panel and spring cylinder lock with key. n Manufactured from zintec, epoxy polyester powder coated in red. Cabinet sizes Type of cabinet Two way vertical inlet Two way horizontal inlet Outlet

Width (mm) Length (mm) Depth (mm) 395 595 295 595 395 295 463 612 325

NB: Please measure size of aperture before ordering.

Description Part Number Two way inlet vertical dry riser cabinet 43/01035 Two way inlet horizontal dry riser cabinet 43/01036 Dry riser outlet cabinet 43/01034 Spare glass for vertical dry riser inlet cabinet – H435mm x W190mm 43/01037 Spare glass for horizontal dry riser inlet cabinet – H235mm x W375mm 43/01038 Spare glass for dry riser outlet cabinet – H475mm x W190mm 46/63274 Spare glass for vertical dry riser inlet cabinet – H430mm x W185mm 81/02349 Spare glass for horizontal dry riser inlet cabinet – H239mm x W344mm 81/02350 Spare glass for dry riser outlet cabinet – H435mm x W282mm 81/02351

Dry Riser Gate Valves With 21⁄2" instantaneous female outlet to BS 336, blank cap and chain, strap and padlock. Dry riser gate valves comply with the requirements of BS 5041:Part 2. Valves can be mounted in boxes complying with BS 5041:Part 4. n Inlet flanged 21⁄2" BSP or 3" BS Table D or 65mm BS 4504 Table 16/21. n Inlet screwed 21⁄2" BSP. Globe Pattern Landing Valves (LP) These screw-down stop valves are primarily used as hydrant outlets on wet rising mains, but are occasionally used on dry risers under special circumstances and after discussion with the fire brigade. n Gunmetal bodies, major working parts in manganese bronze. n Comply with the requirements of BS 504:Part 1 and BS 5154. n Outlets are 21⁄2" instantaneous female to BS 336 and inlets flanged or screwed as required. n Accessories include blank caps and chain, straps and padlocks. Horizontal/Oblique Ref Description A Flanged 2 " BSTD horizontal A Flanged 65mm/ 3"BSTD horizontal A 2 " BSP female inlet horizontal A 2 " BSTD horizontal A 65mm / 3" BSTD horizontal B 2 " BSTD oblique B 65mm / 3" BSTD oblique

Part Number 46/54101 46/54897 46/54923 46/54088 46/54898 46/54090 46/54902

Bib Nose/Right Angle Ref Description C 2 " BSTD bib nose D 2 " BSTD right angle

Part Number 46/54516 46/54089

1 ⁄2

1 ⁄2 1 ⁄2

1 ⁄2

1 ⁄2 1 ⁄2

Outlet Equipment4Section 3

21


B RI G A D E E Q U I P M E N T

Brigade Equipment • General4Section 3

22

Valve Ancillaries

Standpipes/Bars/Keys

The anti-tamper leather strap is for use with globe valves and can be fastened using the 3⁄4" brass padlock. Other accessories include a replacement washer and an air release valve for use at the top of a hydrant system.

Standpipes, keys and bars are used to obtain water from a pressurised mains supply via underground hydrants. The standard outlet for underground valves according to BS 750 is 21⁄2" BSRT male.

Air Release Valves Air valves are fitted at the top of a riser to release air when the riser is charged with water or to admit air when draining off.

Standpipes have as standard a 21⁄2" BSRT female inlet, which is compatible with our underground hydrants. Standpipes are supplied either with single or double head outlets. Outlets are 2" female instantaneous with single twist release (BS 336). The double-head type is supplied with one blank plug as standard. Contractors’ standpipes are supplied with a brass double check valve as standard.

n Screwed 1" BSP male.

Ref A B B C D

Description Part Number Padlock brass 3⁄4" 46/54458 Leather strap 1⁄2" x 13 3⁄4" 46/54456 Leather strap 1⁄2" x 22" 46/54944 Air release valve 1" BSP 46/54175 Washer 21⁄2" instantaneous 46/54470

Technical Specification Standpipe double head, overall length to centre circle of head (A)

839mm

Standpipe single head, overall length to centre circle of head (B)

839mm

Contractors’ standpipe with double check valve, single and double top – overall length (to centre of horizontal pipework)

970mm

Hydrant key length (Part number 46/54177)

1042mm

Hydrant bar key length (Part number 46/54177)

1042mm

Hydrant bar length (Part number 46/54178)

915mm

Hydrant key length (Part number 46/54178)

762mm

Ref A B C D D

Description Part Number Standpipe double head alloy 46/54958 1 2 ⁄2" BSRT female 46/54456 Standpipe single head alloy 46/32575 21⁄2" BSRT female 46/54175 Contractors stand pipe single 46/54470 C/W double check valve Hydrant bar and key alloy 46/54177 Hydrant bar and key mild steel 46/54178 Standpipe base washer 46/57366


B RI G A D E E Q U I P M E N T Underground Hydrants

Blank Plugs

BS 750 Type II Hydrant

Blank plugs are used to seal off water supplies and prevent dirt entering the valves or connectors. Blank plugs are 21⁄2" instantaneous male type.

Screw-down type, cast iron body with manganese bronze valve and forged bronze spindle. Supplied with blank cap, chain and frost valve.

Gunmetal and aluminium blank plugs are pressure resistant; plastic and rubber blank caps act as dust cover only.

Type 2: Inlet flange

3" BS Table ‘E’ or 80mm NP16

Outlet connection

21⁄2" BS Round Thread Male

Body Test Pressure

24 Bar

Seat and Valve tested to

16 Bar

Weight

23kg

Ref A B C D

Description Male alloy – 21⁄2" instantaneous Male gunmetal – 21⁄2" instantaneous Male rubber – 21⁄2" instantaneous Male plastic – 21⁄2" instantaneous

Part Number 46/54322 46/54330 46/54324 46/54325

Dividing Breeching Ref A B

Description Underground hydrant type 2 Plastic blank cap

Part Number 46/57368 46/57382

Unvalved inlet end 21⁄2" male instantaneous and two outlet ends each 21⁄2" female instantaneous with single twist release. Description Aluminium alloy (unvalved) – 21⁄2"instantaneous

Part Number 46/57821

Brigade Equipment • General4Section 3

23


B RI G A D E E Q U I P M E N T

24

Hose and Couplings Hose & Couplings4Section 3

Instantaneous Couplings to BS 336

A selection of hose and couplings assemblies are listed below.

Description 18.3m x 45mm type 2 C/W light alloy couplings 18.3m x 64mm type 2 C/W light alloy couplings 23.0m x 64mm type 2 C/W light alloy couplings 18.3m x 64mm type 1 C/W light alloy couplings 23.0m x 64mm type 1 C/W light alloy couplings

Part Number 46/57391 46/57377 46/54914 46/57379 46/57002

The predominant size is 64mm, the only size recognised by BS 336. The couplings incorporate a double pull release and double ribbed (DR) hose tail. The hose is pushed over the tails and secured by wire or clips.

Layflat Hose to BS 6391:1983 Metric Conversion Table Feet 60’ 75’

Metres 18.3m 23.0m

A range of instantaneous couplings, used for connecting the water hose to the water supply quickly. The instantaneous system is designated by BS 336 and is standard with British fire services for delivery applications.

Inches 1.75" 2.5"

Millimetres 45mm 64mm

Type 1 and Type 2 Layflat Hose General-purpose synthetic delivery hose. Suitable for industrial and rural fire brigades as well as static building protection. For marine use and for general industrial, commercial and civil engineering applications (including water authority applications) where a high-burst performance hose is not necessary. n Lightweight and flexible. n Heat and cold resistant. n Anti-rot and anti-twist. n Type 2 version has a dirt-repellent, external elastomeric coating. Technical Specification – Type 1 and Type 2 Size

Weight (gr/m)

Working pressure Burst pressure (bar) (bar)

13⁄4 " (45mm)

200/230

12

49

2" (51mm)

230

10

39

21⁄2 " (64mm)

280

10

39

Technical Specification Mechanism Hose connection Male – overall length Female – overall length

Ref A B C

Double pull release Ribbed tails 114mm 120mm

Description 21⁄2” x 21⁄2” (64mm x 64mm) tail light alloy 21⁄2” x 21⁄2” (64mm x 64mm) tail gunmetal 21⁄2” x 21⁄2” (64mm x 64mm) tail plastic Washer 21⁄2” instantaneous

Part Number 46/32200 46/32190 46/34215 46/54470


B RI G A D E E Q U I P M E N T Reelfoam Units

Branchpipes provide an adjustable nozzle for altering the curtain of water from a narrow spray to a wide spray. Nozzles provide a fixed jet of water. The basic branchpipe according to BS 336 has an 21⁄2" inlet male instantaneous and outlet threaded 11⁄3" BSP male for either a plain jet or a branchpipe adjustable nozzle. The branchpipe is controlled from ‘shut off’ through ‘jet’ and ‘spray’ to wide-angle ‘curtain’ by rotating the annular sleeve. Dimensions Nozzle – length Branchpipe – overall length Instantaneous adaptor – overall length

120mm 178mm 112mm

n Designed to connect to a manual water fire hose reel. n Controllable discharge. n Operates with 12 litres of alcohol resistant foam concentrate (not supplied – see page 70). n Provides a firefighting capacity greater than the traditional 135 litre foam engine. Description Low expansion unit with 19mm alloy couplings Chrome nozzle – alloy fittings

Ref A B C

Description Part Number Price 21⁄2" Instantaneous integral gunmetal 46/54146 21⁄2" Instantaneous integral diffuser alloy 21⁄2" Instantaneous male x 1⁄2" Jet Blue ABS

46/54393 46/54396

Part Number 46/57431 46/33141

Branchpipes, Nozzles & Reelfoam Units4Section 3

Branchpipes and Nozzles

25


B RI G A D E E Q U I P M E N T

26

Foam

3% and 6% AFFF

Profoam 806 – Protein Foam – Not suitable for extinguishers A premixable, low-expansion foam. Suitable for all types of nozzles, inductors, foam chambers and discharge units.

Foam4Section 3

Reddaway Foam

A synthetic aqueous film forming foam concentrate for extinguishing and securing flammable hydrocarbon liquid fires. Storex Reddaway AFFF is a unique combination of hydrocarbon and fluorochemical surface active agents. AR – AFFF (3% – 6%) - Not suitable for extinguishers A synthetic alcohol resistant aqueous film forming foam concentrate for extinguishing and securing flammable hydrocarbon and polar solvent liquid fires. A polymer additive protects the foam blanket from the destructive action of polar solvents. It is used in high-risk situations where hydrocarbons and polar solvents are stored, processed, or transported. It is ideal for industrial and municipal fire departments. Typical applications include bulk storage tanks, process areas, loading racks, marine terminals, military bases and airports. 3% FP - Not suitable for extinguishers A fluoroprotein firefighting foam concentrate for extinguishing and securing flammable hydrocarbon liquid fires. A protein base material provides a tough cohesive foam blanket with high resistance to heat that quickly smothers, cools and seals the fire risk. Fluorochemical surface active agents combined with the protein base increase the fluidity and fuel repellency of the foam. Ref A B

Description AFFF Reddaway 6% – 25ltr drum AFFF Reddaway 3% – 25ltr drum AR AFFF Reddaway 3% – 6% – 25ltr drum FP Storex Reddaway 3% – 25ltr drum

Part Number 46/63237 46/63238 46/63239 46/63241

Centrifoam 906 – Film Forming Protein – Not suitable for extinguishers A low-expansion foam that forms a vapour seal over hydrocarbon fuel. Filmfoam 916 – AFFF A low-expansion foam suitable for hydrocarbon fuel. Filmfoam A836 – AFFF An alcohol resistant foam, suitable for polar solvent and hydrocarbon fuels. Ref Description Part Number A Profoam 806 Protein Foam 6% – 25ltr drum 46/24224 Centrifoam 906 FFFP 6% – 25ltr drum 46/57661 B Filmfoam 916 AFFF 6% – 25ltr drum 46/57664 Filmfoam A836 AFFF alcohol resistant – 25ltr drum 46/57668


4 SECTION 4 Conventional Detection Devices 28 Addressable Analogue Detection Devices 30-31 Manual Call Points & Sounders 31 Bells Sounders & Strobes 32 Door Holders 33 Sealed Lead Acid Batteries 34 Smoke/Heat Alarms 35 BS5839 Part 6 Grade C System/ CO Alarms 36 Emergency Lighting 37 Conventional Call System/ Test Equipment 38

detection & alarms extinguishers and hose reels ancilliary items brigade equipment detection and alarms

27-38


DETECTION & ALARMS

28

Fire Control & Detection Equipment4Section 4

Conventional Detection Devices Apollo Range

Apollo Accessories

Complying to EN54 Pts 5/7/8 and LPC certificated.

The series 65 range of conventional detection devices offer a complete answer to all your requirements. They are compatible with any conventional control panel. Ionisation Smoke Detector Series 65 Description Ionisation Smoke Detector Series 65

Code Number 82/00399 (a)

Optical Smoke Detector Series 65 Description Optical Smoke Detector Series 65

Code Number 82/00400 (b)

A range of bases to complement series 65 devices and to offer many alternative options. Mounting Bases Description Mounting base standard series 60/65 Mounting base with line diode series 60/65

Technical Specification Apollo

Heat Detectors Description Heat Detector CR (84-100C) Series 65 Heat Detector A1R (54-65C) Series 65

Code Number 82/00401 82/00402 (c)

Technical Specification

Voltage

Ion

Opt

Heat

Comb

24 DC

24V DC

24V DC

24V DC

Quiescent current

45µA

45µA

53µA

Alarm current

52mA

52mA

52mA

52mA

Relay base max switching contact 50 volts

Code Number 82/00046 (d) 82/00050


DETECTION & ALARMS

29

Hochiki Range

Hochiki Accessories

The CDX range is a well established range of conventional devices with an outstanding performance record. Hochiki's flat response technology enables the photoelectronic device to be equally sensitive to a much wider range of combustible materials.

A range of bases to complement the CDX range of devices offering many alternative options.

Ionisation Beam Detector Description Ionisation Smoke Detector CDX Range

Code Number 82/00037 (a)

Photoelectric Smoke Detector Description Photoelectric Smoke Detector CDX Range

Code Number 82/00040 (b)

Heat Detectors Description Fixed Temperature (90C) CDX Range Rate of rise Grade 1 (60C) CDX Range Combined Heat Grade 2 (60C) CDX Range

Code Number 82/00045 82/00042 (c) 82/00043

Technical Specification - For all devices

Operating voltage 15 - 30V DC Quiescent current 35ÂľA Alarm current 40mA For all devices

The Hochiki beam detector is tested to BS5839 Pt5 and is LPCB approved. Direct wall mounting ensures virtually no vibration when in use. Photoelectric Beam Detector Description Two Wire Beam Detector CDX Range

Code Number 82/00290

Mounting Bases (Conventional)

Description Electronic free mounting base CDX Range Schottky line continuity base (Safeline) with remote indicator Remote indicator output CDX Range

Code Number 82/00047 (b) 82/00049 82/00051

Fire Control & Detection Equipment4Section 4

Conventional Detection Devices


30

DETECTION & ALARMS

Fire Control & Detection Equipment4Section 4

Addressable Analogue Detection Devices Hochiki Accessories

Apollo Range

KAC Manual Call Points

Manual Call Points (Conventional) KAC Manual callpoints - the major producer of call points offering surface and flush options with accessories - all to EN54 Pt2 and LPC certificated Description EN54 MCP for indoor use Transparent hinged cover Replacement glass Spare test key Pattress box

Code Number 82/00404 82/00406 82/00405 82/00407 82/00062

Class 2000 spares Description Transparent hinged cover Replacement glass Spare test key Pattress box

Code Number 82/00056 82/00058 82/00060 82/00062

Apollo XP95 Analogue Devices All devices are moulded in self extinguishing white polycarbonate material and are set to EN54 thresholds. Description XP95 Ionisation smoke device XP95 Optical smoke device XP95 Multi sensor device XP95 Temperature (STD) device XP95 High temp device XP95 Loop powered beam detector XP95 Beam detector reflector

Code Number 82/00095 82/00097 82/00103 82/00100 82/00101 82/00289 82/00291

(a) (b) (c) (d)

Technical Specification

Supply voltage V DC Modulation voltage V DC Quiescent current Alarm current

Ion

Opt

Heat

Multi

17 - 28

17 - 28

17 - 28

14 - 28

5-9

5-9

5-9

5-9

280µA

340µA

250µA

500µA

2mA

4mA

2mA

3.5mA

Apollo Accessories Apollo Bases & Accessories XP95 Range Description Common base device and expert card Isolating base (20 devices) Isolator base Low power relay base Blank expert card Apollo Test Set

Code Number 82/00104 82/00108 82/00110 82/00091 82/00112 82/00133


DETECTION & ALARMS

31

Hochiki Range

Apollo XP95

Manual Call Points (Addressable) The XP95 range of manual call points uses the KAC world series call point It is available in three types. Approved to BS5839 Pt 2.

Hochiki ASX Analogue Devices This range is designed to meet European approvals EN54 Pt5, Pt 7 and Pt 9 set to EN54 thresholds. Description ASX Optical smoke device ASX Ionisation smoke device ASX Heat device R/R ASX Multi sensor device

Description Weather Proof Manual Call Point Series XP95 Surface Manual Call point for Series XP95 Flush Manual Call point for Series XP95

Code Number 82/00098 82/00096 82/00099 82/000102

(a) (b) (c) (d)

Technical Specification Ion

Opt

Heat

Multi

24

24

24

24

Low

140µA

120µA

90µA

120µA

Normal

350µA

310µA

350µA

450µA

127

127

127

127

Supply voltage V DC Standby current

Devices per loop

Code Number 82/00127 (a) 82/00125 82/00128

Technical Specification - Apollo Operating voltage 17 - 28V DC Communication protocol 5 - 9V Quiescent current 350µA Alarm current 2mA

Apollo Apollo Sounders Description 90dB sounder low profile loop powered sounder 100dB loop sounder

Code Number 82/00131 82/00129

Technical Specification - Apollo

Hochiki Accessories Hochiki Bases & Accessories ASX Range Description Common base Addressable base Master addressable base Isolator module Mini zone monitoring module Zone monitor Relay output module Dual switch monitor Hand held programmer

Code Number 82/00105 82/00106 82/00107 82/00114 82/00115 82/00116 82/00118 82/00119 82/00124

Low profile sounder Sound output 85dB (A) @ 1 metre Current consumption 3mA 100dB sounder Operating voltage 14 - 28V DC polarity sensitive Quiescent current 1.1mA Alarm current 4.5mA IP42

Fire Control & Detection Equipment4Section 4

Addressable Analogue Manual Call Points and Sounders


DETECTION & ALARMS

32

Fire Control Accessories4Section 4

Bells, Sounders, Strobes for any System Fulleon

Fulleon Bells Description 6” Motorised bell 24 volt

Code Number 82/00064 (a)

Roshni Low Profile Description Roshni low profile, shallow base, 24 volt

Code Number 82/00070 (b)

Standard Squashni Sounder Description Standard Squashni sounder. Tone 3. White Standard Squashni sounder cover. White

Code Number 82/00069 82/00068 (c)

Technical Specification Bells 6” Supply voltage Alarm current 25mA Output 93/95dB (A) Roshni Supply voltage 9 - 28V DC Alarm current 16mA Output @ 1 mtr 102dB (A)

8” 18 - 30V DC 28mA 95/97dB (A) @ 1 metre

18 - 30V DC

@ 1 metre

Squashni Supply voltage 10 - 28V DC Alarm current 18mA Output @ 1 mtr 93dB (A)

Singe Voice Fire Cryer Enhanced Sounder Description Code Number Singe message non-sync. Voice enhanced sounder 82/00074 (d) Alternative messages available Banshee Sounder Description Banshee LP.LF.Red

Code Number 82/00071

Kobishi Strobe Description Strobe light with interchangeable red lens

Code Number 82/00075 (e)

Technical Specification Fire Cryer Alarm current 20mA Supply voltage

Kobishi Strobe Supply voltage 24V DC 24V DC Alarm current 35mA Flash rate 60 - 100


DETECTION & ALARMS

33

Fulleon

Vimpex

Fulleon door holders designed to hold open fire or smoke stop doors.

Vimpex door holders are IP54 rated and comply with BS 5839 Pt3 and EN 1155. A special feature is a spring loaded device to eliminate residual magnetism. A manual release button is standard for both models.

In the event of an emergency they will release the door. A manual release button is standard for both models. Door Holders & Accessories Description Wall mounted magnet door release 230 volt Wall mounted magnet door release 24 volt Floor mounted bracket for above Technical Specification - Fulleon Power supply Holding current Kilogram force

24V DC or 230V AC 50mA or 2VA 40kg

Code Number 82/00082 (a) 82/00080 82/00085

Door Holders & Accessories Description Surface door retainer with back box 24 volt Surface door retainer with back box 230 volt Floor mounted bracket for above Technical Specification - Vimpex Power supply Holding current Kilogram force

24V DC or 230V AC 25mA or 1.5VA 20kg

Code Number 82/00081 (c) 82/00083 82/00084

Fire Control Accessories4Section 4

Door Holders for any System


34

DETECTION & ALARMS

Sealed Lead Acid Batteries Fire Control Accessories4Section 4

The NP range is highly respected and offers the following features. n Deep discharge recovery n Security from electrolyte leakage n Oxygen recombining n Float or cyclic use n Usable in any orientation n Lead calcium grids giving long life Description 1.2AH 12 volt SLA Battery 2.1AH 12 volt SLA Battery 2.8AH 12 volt SLA Battery 7.0AH 12 volt SLA Battery 12.0AH 12 volt SLA Battery 24.0AH 12 volt SLA Battery

Code Number 82/00192 82/00193 82/00194 82/00195 82/00196 82/00197

A guide to SLA Battery back up capacity The capacity of SLA batteries fitted to the Control and Indicating Equipment is determined by the type of system installed (L or P) and is specified in BS 5839 Part 1 1988, section 16.5 Duration of the standby supply the following is a simple guide to calculate the capacity. 1. Establish the total standby current drawn by all devices connected to and including the Control and Indicating Equipment. Add all the current readings together. Don’t forget to pay attention to the decimal places. i.e. mA 10-3, µA 10-6, etc. 2. Establish the total alarm current drawn by all devises connected to and including the Control and Indicating Equipment. Add all the current readings together. Don’t forget to pay attention to the decimal places. i.e. mA 10-3, µA 10-6, etc.

Example Product Panel x 1 Ionisation x 10 Optical x 5 Heat x 2 MCP x 4 Sounders x 6 Total

Standby

Total Standby

Alarm

Total Alarm

35mA 45µA 45µA 53µA 0 0

35mA 450µA 225µA 106µA 0 0

100mA 52mA 52mA 52mA 50mA 16mA

100mA 520mA 260mA 104mA 200mA 96mA

35.143mA

35.781mA

332mA

1.280 A

The system has to meet the requirements for an L type environment, (life safety) and is supervised at intervals of not more than 12 hours. Total standby current multiplied by 24 hours = 35.781mA x 24 = 0.858744 Ah. Total alarm current multiplied by 30 min. = 1.280A x 0.5 = 0.64 Ah. Add the standby Ah and the Alarm Ah = 0.858744 + 0.64 = 1.498744 Ah Add 20% margin for charging. = 1.8 Ah. It is common practice to choose the nearest available size moving up a size if

3. Multiply the standby current by the number of hours standby required. 4. As all the L and P systems require an alarm period of 30 minutes (except in very special cases, see standard) total alarm current should be multiplied by 0.5 (half of one hour) 5. Add the results of 3 and 4 together 6. BS 5839 Part 1 specifies that the batteries are able to provide its designed standby duration after 24 hours charge from it’s discharge state. To allow for this the capacity of the battery should be increased by 20% to overcome problems with charge rates.

necessary. So in this case the next available size will be 2.2 Ah.


DETECTION & ALARMS

35

Smoke/Heat Alarms BRK

All products are kite marked to BS5446 Pt 1 and C.E. approved except heat alarms which are tested EN54 Pt 5 sensitivity and BS5446 Pt 1 environmental

BS5446 Pt1 1990 Smoke Alarms Description IONISATION 230 volt - 10 year lithium secondary supply with silence and interconnect OPTICAL 230 volt - 10 year lithium secondary supply with silence and interconnect HEAT 230 volt - 10 year lithium secondary supply and interconnect

Smoke & Heat Alarm Accessories Description Common base (Smoke Alarm) Common base (Heat Alarm)

Code Number

9 Volt DC Units Description IONISATION Basic Product

Code Number 82/00203

(a)

BRK 82/00138

(a)

82/00398

(b)

82/00140

(c)

9 Volt DC Units Description IONISATION ALARM Ionisation smoke alarm OPTICAL alarm Optical smoke alarm interconnectable with alkaline battery Code Number 82/00218 (d) 82/00206

Code Number 82/00205

(b)

82/00212

(c)

230 Volt/9v DC AC/DC Unit Description IONISATION AC/DC + Alkaline + Interconnect OPTICAL AC/DC + Alkaline + Interconnect

82/00210

(d)

82/00214

(e)

Accessories Description Common Base (Smoke Alarm)

Code Number 82/00218

Code Number

Fire & Gas Alarms4Section 4

Kidde


DETECTION & ALARMS

Fire & Gas Alarms4Section 4

36

Fire Alarms

CO Alarms

BRK

Kidde Sensors

Flexi-Point - BS5839 Pt6 Grade C n 230V AC Supply CO Alarms Description Code Number 9CO-5 4.5v DC Carbon Monoxide Alarm - Basic 82/00223 900-0146 4.5v DC Carbon Monoxide Alarm - Digital Display 82/00421

n 20 devices can be wired in n Built in call point (BS5839 Pt2) n Built in sounder n 10 year lithium secondary supply 9V DC n Enabling key switch Slave Panel As above less n Enabling key switch Description Callpoint. Master Auxiliary. Master

Code Number 82/00136 (a) 82/00137 (b)

Certified by BSI to conform to EN 50291, with a 5 year manufacturer’s warranty. These alarms are Loud 85 decibel alarm with a flashing red light to warn when dangerous levels of CO are detected. They use proprietary electrochemical sensor technology with a self-diagnosing feature will indicate unit or sensor malfunction. Easy to install, with an automatic endof-life warning after seven years, uses 3 x AA battery (supplied). Additional features of the 900-0146 Digital Display alarm only This alarm also has digital display continuously shows concentration of CO detected above 30ppm (parts per million), with peak level function to display the highest CO reading taken above 11ppm since the last peak level reset or power-up. The alarm is backlit display to take readings in the dark.


DETECTION & ALARMS

37

Emergency Lighting Thomas Glover

e

f

A range of emergency luminaires in compliance to BSEN 60598-1, BSEN 4533-10Z, BSEN 60924 and suitable to be used in a BS5266 system. Models available are Bricklite models IP65 giving 54 lumens output - available in NM and M modes all at 3 hours operation and featuring “The Friendly Clip Cover” Low profile standard IP20 giving 60 lumens output available in NM, M and S. All at 3 hours operation.

NM - Non maintained - lamp illuminated under mains failure M - Maintained - lamp switched under mains failure. S - Sustained - second lamp illuminated under mains failure. Features include • Friendly clip cover • Ni-Cad battery locater • Besa box mountings • Double insulated • Impregnated transformers and invertors

Exit Boxes 8 watt wall mounted steel enclosures - 3 hours operation. Twin Spot Light Units 2 x 20 watt spots non maintained - metal enclosure - for commercial/ industrial use. Adhesive Eurogram Kits for bricklites and for low profiles

Description Metal exit box 8 watt maintained 2 by 20 watt twin spot (excludes batteries) IP65 bricklite 3 Hr. 8 watt maintained IP65 bricklite 3 Hr. 8 watt non-maintained IP20 3Hr. 8 watt maintained IP20 3Hr. 8 watt non-maintained Adhesive eurogram kit (bricklite) Adhesive eurogram kit for IP20 model

Code Number 82/00272 (a) 82/00271 (b) 82/00002 82/00001 (c) 82/00006 82/00005 (d) 82/00003 82/00004

Batteries (Ni-Cad Replacement Hi-Temp Ni-cad Battery, packs in C-Cell and D-Cell sizes Description C Size Ni-Cad 3.6V 1.5 AH D Size Ni-Cad 2.4V 4AH

Code Number 82/00134 (e) 82/00135 (f)

Emergency Lighting4Section 4

Thomas Glover


DETECTION & ALARMS

38

Conventional Call System & Test Equipment 4Section 4

Conventional Call Systems

Test Equipment No Climb

Canisters of “Ozone” friendly smoke suitable for testing ionisation or optical smoke detectors. The 150 ML hand held aerosol will provide up to 200 tests. The 250 ml aerosol is to be used with dispenser kit. Universal detector removal tool suitable for use with a wide range of detectors from 65m to 110mm diameter.

Disabled Persons Toilet Alarm

n n n

Comes as complete kits

Aerosol dispenser/tester for use with 250ml aerosol - lightweight -

Standard or economy kits

suitable for floor and ceiling voids. Transparent cup enables view of detector L.E.D.

Many options on extras

Description Standard Kit Economy kit

Code Number 82/00231 82/00232

Extension pole to extend area of activity. Description Aerosol smoke dispensor/tester Aerosol Spray 150ml Aerosol Spray 200ml (use with dispensers)

Code Number 82/00199 (a) 82/00202 (b) 82/00200

Description Universal detector remover 1.2 to 4.5 meter telescopic extension pole

Code Number 82/00198 (c) 82/00201

ACT

Intelligent Battery Tester The professional tester which shows on the L.C.D. by scrolling through. • Capacity • Voltage • Temperance

Description Intelligent Battery Tester Gold IBT

Code Number 82/00396 (d)


39 Information Update Fire fighting foams containing Perfluorooctane Sulphonate (PFOS) The Department for Environment, Food and Rural Affairs (DEFRA) issued a consultation paper in October 2004 on UK proposals to introduce regulations on the restriction of use and marketing of perfluorooctane sulphonate. PFOS, recently proved to be bioaccumulative, persistent, toxic and a risk to the aquatic and terrestrial environment, have been used in fire fighting foams for many years.

Fire Safety Order (FSO) The Fire Safety Order will encompass and replace all existing fire legislations: • Fire Precautions Act 1971 • Fire Precautions (Workplace) Regulations 1997/1999 • Management of Health and Safety in the Workplace Regulations 1999 • + 100 pieces of related legislation and only apply in England and Wales.

Formulators, producers and users of PFOS in fire fighting foams will be affected by these proposals. It is thought that as substitutes exist for fire fighting foams a time limited derogation will be put in place before a total phase out of PFOS. If these proposals go ahead, fire fighting foams containing PFOS will have to be incinerated at high temperature.

Who will be affected by the FSO?

How do I know if the extinguishers I buy contain PFOs?

• Anyone responsible for a building to which the public have access

The FIREPOWER range have been PFOS free since 2001.

Disability Discrimination Act 1995: Part III

• Non domestic premises • All employers • Self employed

• Voluntary organisations

Since the 1st of October 2004 service providers have had a legal requirement to make ‘reasonable adjustments’ to their premises to ensure disabled people can use their services.

All premises affected by the FSO will have to carry out a fire risk assessment.

Who is affected by the DDA?

• Reduce the risk of fire and the spread of fire

Everyone that provides paid or free goods, facilities or services to the public is defined as a service provider. Eg. Hotels, Restaurants, Retail shops, Schools, Hospitals, Theatres, Airports etc...

• Extend protection explicitly to all occupants, not just employees

What types of adjustments need to be made to the premises? These adjustments relate to the building’s ‘physical features’ i.e. entrances/exits, floor layouts, toilet facilities, printed materials, fire & safety provisions etc... What is considered ‘reasonable’? The Act does not list what particular adjustments should be made to a building. The adjustments made will depend upon the size and resource of the service provider and how practical it is to make these changes. Disability can take many forms such as sight or hearing impairment, physical and mobility problems, mental health problems or learning difficulties. These disabilities need to be taken into account when developing a fire safety strategy. Thomas Glover offers a range of products that can help customers tailor their fire safety strategy to reflect the requirements of the DDA: • Supplementing Fire Alarm bells with visual flashing beacons to alert the hard of hearing • Braille and tactile signs specifically designed for blind and partially sighted people • Evacuation chairs and Dorgard to ease mobility through the building For more information please log on to www.drc-gb.org Fire (Scotland) Act The Scottish Executive is proposing new primary legislation to consolidate existing fire regulatory requirements and to reform the operation of the fire and rescue service. For more information please log on to www.scotland.gov.uk

Aim of the FSO:

• Protect the fire fighters • Protection of property For more information please log on to www.odpm.gov.uk

Which Extinguisher to use Which A Extinguisher Freely burning to use materials. Water Water with Additive Spray Foam ABC Dry Powder Dry Powder Special Metal Dry Powder Special Monnex C02 Gas Hose Reels Wet Chemical

B Flammable liquids

C Flammable gases

D Flammable metals

F Electrical Hazards

Cooking oils and fat


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.