Daikin UK Product Catalogue 2011 - part2

Page 1

VRV® systems

Outdoor units new new new

Air-Cooled VRV®-Q Introduction RQEQ-P / RQYQ-P Replacement VRV®III Heat Recovery / Heat Pump Air-Cooled VRV® REY(H)Q-P VRV®III Heat Recovery – High COP REYQ-P8/P9 VRV®III Heat Recovery BSVQ / BSV Individual / Multi Branch Selector Boxes RXHQ-P VRV®III Heating only RXYHQ-P9 VRV®III Heat Pump – High COP RXYQ-P9 VRV®III Heat Pump – Small Footprint RXYRQ-P VRV®III Heat Pump – Stylish Indoors RXYSQ-P8 VRV®III-S Heat Pump ® Water-Cooled VRV RWEYQ-P Heat Pump RWEYQ-P Heat Recovery Geothermal Application (Heat Pump & Heat Recovery) RWEYQ-PR

Indoor units 1. Cassette units

For a copy of our latest Price List please call 0845 6419000

133 134 136 137 138 139 141 142 143 144 145

4. Ceiling suspended units

FXFQ-P9 FXZQ-M9 FXCQ-M8 FXKQ-MA

146 147 148 149

2. Concealed ceiling units

128 130

FXDQ-M9 FXDQ-P7 FXSQ-P FXMQ-P7 FXMQ-MA

150 151 152 153 154

FXHQ-MA FXUQ-MA

156 157

5. Floor standing units

FXNQ-P FXLQ-P

158 159

6. Air curtains new

CYQ-DK

7. Hot water module

160 161

3. Wall mounted units

FXAQ-P

155

126 VRV_contents.indd 126

30/03/2011 18:44


The simple switchover for R22 systems

REDUCED REDUCED

REDUCED

Plug in VRV®III-Q

Up to

50%

Existing System

SAVED

Act now. Virgin R22 banned in January 2010 Save time and money, without compromising performance, when you replace existing R22 equipment. VRV®III-Q is the smart way to achieve: • • • • • •

Dramatically reduced installed cost – up to 50% saving compared with complete new system. Ability to reuse all existing pipework and possibility to reuse existing fan coils. Flexibility to use with existing pipework connected to other non-Daikin systems. Automatic pipework cleaning function. Higher energy efficiency and lower CO2 emissions than retrofitting refrigerant. Major potential to increase system capacity.

your comfort. our world.

For more information, visit www.daikin.co.uk/r22r Midlands Region

Northern Region

North London

Central London

0845 641 9370

0845 641 9340

0845 641 9360

0845 641 9350

South London 0845 641 9355

Scotland Region 0845 641 9330

Western Region 0845 641 9320

127 2515_BOOK_VRV_2011.indb 127

24/03/2011 12:23


Replacement VRV®

Daikin solution to R-22 phase out

R-410A VRV®-Q outdoor unit

R-22 refrigerant piping

* All units older than the K-Series must be replaced. * For heat recovery applications, the BS-boxes need to be replaced.

R-22 or R-410A indoor

What is R-22 and why is it phased-out? R-22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems. When R-22 is released into the air, the ultraviolet rays of the sun cause it to decompose and chlorine is released in the stratosphere. Chlorine reacts with ozone, reducing the amount of the ozone. Due to ozone layer depletion, harmful ultraviolet rays reach the surface of the earth giving rise to a number of health and environmental issues. The international community therefore, signed the Montreal Protocol to phase out ozone depletion materials by 2030. The European Union however, decided to ban R-22 already in 2015.

Technologies of VRV®-Q VRV ® -Q

Pressure

Indoor A

}

3.3 MPa

}

3.8 MPa

Pressure sensor

B

Change over valve Temperature sensor

~

~

Enthalpy

Antireverse valve

Temperature sensor

Catcher

A Decompression to 3.3MPa(s) R-22 existing piping can be used B Extra sub cool circuit high COP

Contamination is collected by the power of the refrigerant gas

Reduced pressure

Refrigerant pipe cleaning

As R-22 VRV® systems work on a lower pressure than R-410A systems; thus the copper refrigerant piping was also designed for these lower pressures. Therefore the Replacement VRV® (VRV®-Q) must operate at lower pressures than the standard VRV®III series. However thanks to the sub cool circuit a high efficiency level can be kept even with the lower pressures.

When replacing an air conditioning system, the piping is normally replaced as well since traces of old refrigerant and oil mixed with the oil and refrigerant of the new system can cause the equipment to malfunction. In order to allow re-use of existing R-22 piping with an R-410A system Daikin developed a technology to capture and retain the contamination left in the refrigerant piping. During the charging of the system, R-410A refrigerant starts circulating through the copper piping collecting the contamination left in the refrigerant piping. The refrigerant including the remaining oil from the R-22 system is filtered in the outdoor unit and the contamination is deposited in the outdoor unit. This process is executed only once and takes about 1 hour (depending on system characteristics). Daikin is the first manufacturer in the industry to develop this combination of automatic charging and refrigerant pipe cleaning function.

128 2515_BOOK_VRV_2011.indb 128

24/03/2011 12:23


Features of VRV®-Q Warranty

Possibility to increase capacity

Unlike using drop in refrigerants, the VRV®-Q condensing unit is provided with a manufacturers warranty, providing the existing pipework condition is deemed suitable for re-use.

Cooling loads often increase subsequent to the initial installation of the air conditioning system. The Replacement VRV® (VRV®-Q) enables system capacity to be increased without changing the refrigerant piping (depending on system characteristics). For example: It is possible to install a 16 HP Replacement VRV® on the refrigerant piping of an R-22 10 HP system.

Fast installation It is not necessary to remove the existing piping and even the indoor units can remain (depending on type of indoor unit). The unit automatically charges the refrigerant and cleans the refrigerant piping. This unique Daikin feature makes the installation time even shorter.

10 HP

16 HP

1.

Limited and planned-downtime As the refrigerant piping can be maintained the installation is less intrusive and less time consuming than for a completely new system. Moreover, downtime can be carefully planned: whereas if a problem occurs when not enough reclaimed R-22 is available, a long and unplanned downtime can be the result.

2.

Limited and phased investment cost It is possible to spread the various stages of replacement over a certain period of time because the indoor units can remain in many cases. The air conditioning replacement therefore, can be incorporated in the general refurbishment schedule of the building and the investment cost can be spread. A further reduction in installation cost can be achieved by maintaining the old refrigerant copper pipe work.

No restrictions on system history

1. Keep main piping

2. Add indoor units

Environmental awareness R-410A not only has a zero ozone depletion potential, it is also proven to be more energy efficient than R-22.

High efficiency

As a result of the combined automatic charging and refrigerant pipe cleaning function, it is possible to ensure a clean piping network, even when a compressor breakdown has previously occurred.

Upgrading an old R-22 system to a Replacement VRV® system will result in increased system efficiency. Efficiency gains of more than 40% can be realised, by virtue of technological developments in heat pump technology and the more efficient R-410A refrigerant. Increased energy efficiency equals lower energy consumption, subsequent lower energy costs and lower CO2 emissions.

EER of a 10 HP system

COP of a 10 HP system

4.50

4.00

3.50

3.00

3.98

2.50

3.10

2.00

2.37

1.50

R-22

R-407C

VRV®-Q

40% More efficient

4.00 3.00

R-22

3.10

R-407C

VRV®-Q

25% More efficient

R-22: RSXY10KA7 R-407C: RSXYP10L7 R-410A: RQYQ280P

129 2515_BOOK_VRV_2011.indb 129

24/03/2011 12:23


Specifications HEAT RECOVERY RQCEQ-P

280 RQEQ140P

Outdoor unit modules

360

2

RQEQ180P

2

460

500

2

1

1

2

540

636

3

Capacity Power input

HP

10

13

16

18

20

744

1

1

816

848

2

1

3

1

2

3

4

22

24

26

28

30

RQEQ212P Capacity range

712

1

cooling

nom.

kW

28.0

36.0

45.0

50.0

54.0

63.6

71.2

74.4

81.6

84.8

heating

nom.

kW

32.0

40.0

52.0

56.0

60.0

67.2

78.4

80.8

87.2

89.6

cooling

nom.

kW

7.04

10.3

12.2

13.9

15.5

21.9

21.2

23.3

27.1

29.2

heating

nom.

kW

8.00

10.7

13.4

14.7

16.1

17.7

20.7

21.2

23.1

23.6

EER

cooling

3.98

3.48

3.77

3.61

3.48

2.90

3.36

3.19

3.01

2.90

COP

heating

4.00

3.72

3.89

3.80

3.72

3.79

3.80

3.81

3.77

3.79

Max n° of indoor units to be connected Indoor index connection

Dimensions

minimum

20

26

29

33

36

40

43

47

50

162.5

200

225

250

275

300

325

350

375

standard

250

325

400

450

500

550

600

650

700

750

maximum

325

422.5

520

585

650

715

780

845

910

975

unit

height

mm

width

mm

depth

mm

Weight Sound pressure

16 125

1680 635+ 635

nom.

dBA

635+ 635+ 635+ 635 765

kg cooling

635+ 635+ 635

175+ 175 57

175+ 175+175 61

61

62

air flow rate (nominal at 230V)

175+175 +175+179

175+175 +179+179

175+179 +179+179

179+179+ 179+179

64

63

64

65

66

63

type Fan

179+ 179+179 Propeller

cooling

external static pressure (max.)

m3/min

95+ 95

95+ 95 + 110

110+110

95+ 110+110

110+ 110 + 110

Pa

motor

type

Operation range

cooling

min. - max.

°CDB

-5~43

heating

min. - max.

°CWB

-20~15.5

Hermetically sealed scroll compressor

type

R-410A

charge

kg

10.3+ 10.3

liquid

mm

9.52

gas

mm

22.2

discharge gas

mm

pressure equiliser tube

mm

max. total length

m

10.6+ 10.6

10.3+10.3 +10.6

10.3+10.6 +10.6

control

Piping connections

110+ 110+ 110+ 110

78

Compressor

Refrigerant

95+ 110+ 110+ 110

10.6+10.6 +10.6

11.2+11.2 +11.2

10.3+10.6 +10.6+11.2

10.3+10.6 +11.2+11.2

10.6+11.2 +11.2+11.2

11.2+11.2 +11.2+11.2

Electronic expansion valve 12.7

15.9

25.4 19.1

-

19.1

28.6

34.9

22.2 -

-

25.4

-

-

-

-

28.6 -

-

-

300

max. length between

OU-IU

m

120 (actual length)

level difference

OU-IU

m

50 (outdoor unit in highest position)

Power Supply

3~. 400V. 50Hz

Notes: Nominal cooling capacities are based on : indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 7.5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m

Accessories VRV®III-Q - REPLACEMENT VRV® - Heat recovery

RQCEQ460PY1 RQCEQ500PY1

RQCEQ280PY1 RQCEQ360PY1

Fixing box Outdoor unit multi connection piping kit

RQCEQ540PY1 RQCEQ636PY1

RQCEQ712PY1 RQCEQ744PY1 RQCEQ816PY1 RQCEQ848PY1

KJB111A BHFP26P36C

BHFP26P63C

BHFP26P84C

130 2515_BOOK_VRV_2011.indb 130

24/03/2011 12:23


HEAT PUMP Outdoor system System Capacity range Cooling capacity Heating capacity Power input - 50Hz

RQYQ140P *RQYQ8P *RQYQ10P *RQYQ12P *RQYQ14P *RQYQ16P *RQYQ18P *RQYQ20P *RQYQ22P *RQYQ24P *RQYQ26P *RQYQ28P *RQYQ30P

Outdoor unit module 1 Outdoor unit module 2 Nom. Nom. Cooling Heating

RQYQ140P RQYQ8P

HP kW kW kW kW

Nom. Nom.

EER COP Maximum number of connectable indoor units Dimensions Unit HeightxWidthxDepth mm Weight Sound pressure level Operation range Refrigerant Piping connections

Power supply

Unit Cooling Cooling Heating Type Liquid Gas Piping length Total piping length Level difference

kg dBA °CDB °CWB

Nom. Min.~Max. Min.~Max.

OD OD Max. System OU - IU IU - IU Phase / Frequency / Voltage

OU - IU Actual Max.

mm mm m m m m Hz / V

5 14.0 16.0 3.36 3.91 4.17 4.09 10 1,680x635 x765 175 54 -5~43 -20~16 R-410A 9.5 15.9 120 300 50/40 15 3~ / 50 / 400

8 22.4 25 5.24 6.42 4.27 3.89 17

RQYQ10P RQYQ12P RQYQ14P RQYQ16P RQYQ8P RQYQ8P RQYQ10P RQYQ12P RQYQ10P RQYQ12P RQYQ14P RQYQ10P RQYQ12P RQYQ12P RQYQ12P RQYQ16P RQYQ16P RQYQ16P 10 12 14 16 18 20 22 24 26 28 30 28 33.5 40 45 50.4 55.9 61.5 67 73 78.5 85 31.5 37.5 45 50 56.5 62.5 69 75 81.5 87.5 95 7.64 10.10 11.6 13.6 12.9 15.4 17.8 20.2 21.3 23.7 25.2 8.59 10.20 12.2 13.6 15.1 16.7 18.8 20.4 22.2 23.8 25.8 3.66 3.32 3.45 3.31 3.91 3.63 3.46 3.32 3.43 3.31 3.37 3.67 3.68 3.69 3.68 3.74 3.74 3.67 3.68 3.67 3.68 3.68 21 26 30 34 39 43 47 52 56 60 64 1,680x930x765 1,680x1,240x765 -

230 57

284

381

58

-

60

61

62

63

-5~43 -20~15.5 R-410A 9.5 19.1

12.7

15.9

22.2

19.1

28.6

34.9

150 300 50 (Outdoor unit in highest position)/ 40 (Indoor unit in highest position) 15 3~ / 50 / 400

Notes: Nominal cooling capacities are based on : indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 7.5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m

HEAT PUMP Outdoor system System

Cooling capacity Heating capacity Power input - 50Hz

Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3 Nom. Nom. Cooling Nom. Heating Nom.

EER COP Maximum number of connectable indoor units Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping connections Liquid OD Gas OD Piping length Max. OU - IU Total piping length System Actual Level difference OU - IU IU - IU Max. Power supply Phase / Frequency / Voltage

kW kW kW kW

dBA °CDB °CWB mm mm m m m m Hz / V

*RQYQ32P

*RQYQ34P

*RQYQ36P

*RQYQ38P

*RQYQ40P

*RQYQ42P

*RQYQ44P

*RQYQ46P

*RQYQ48P

RQYQ16P RQYQ16P 90 100 27.2 27.2 3.31 3.68

RQYQ10P RQYQ10P RQYQ14P 96 108 26.9 29.4 3.57 3.67

RQYQ10P RQYQ10P RQYQ16P 101 113 28.9 30.8 3.49 3.67

RQYQ10P RQYQ12P RQYQ16P 107 119 31.4 32.4 3.41 3.67

RQYQ12P RQYQ12P RQYQ16P 112 125 33.8 34.0 3.31 3.68 64

RQYQ10P RQYQ16P RQYQ16P 118 132 34.9 35.8 3.38 3.69

RQYQ12P RQYQ16P RQYQ16P 124 138 35.3 36.0 3.51 3.83

RQYQ14P RQYQ16P RQYQ16P 130 145 38.8 39.4 3.35 3.68

RQYQ16P RQYQ16P RQYQ16P 135 150 40.8 40.8 3.31 3.68

63

64

65 -5~43 -20~15.5 R-410A 19.1

34.9

41.3 150 300 50 (Outdoor unit in highest position)/ 40 (Indoor unit in highest position) 15 3~ / 50 / 400

Notes: Nominal cooling capacities are based on : indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 7.5m, level difference: 0m. Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping : 7.5m, level difference : 0m

Accessories VRV®III-Q - REPLACEMENT VRV® - Heat pump

RQYQ8~16P

RQYQ140P

Cool / Heat selector Fixing box Outdoor unit multi connection piping kit

RQYQ18~32P

RQYQ34~48P

BHFP22P100

BHFP22P151

KRC19-26A KJB111A -

-

131 2515_BOOK_VRV_2011.indb 131

24/03/2011 12:23


Achieve the highest energy efficiency levels in the industry Cooling

Cooling

Extracted Heat

Extracted Heat

VRV Heat Recovery System

Heating

Hot Water

Ventilation

Door Curtain

VRV®III Heat Recovery systems deliver energy efficiency levels of up to 91 VRV®III Heat Recovery is the all-in-one solution to maximise energy efficiency. A fully integrated system for heating, cooling, air curtains and hot water – to help achieve zero waste heat. • Free extracted heat from areas being cooled is diverted to areas requiring heat – to minimise operating costs. • Reclaimed heat can be used to power door air curtains and even hot water supplies. • Numerous heat recovery options, with 14 different types of indoor units available. • Suitable for all size of systems: a single outdoor unit (11kW to 170kW) can connect up to 64 indoor units.

your comfort. our world.

For more information please visit www.daikin.co.uk/heat-recovery

Midlands Region

Northern Region

North London

Central London

South London

0845 641 9370

0845 641 9340

0845 641 9360

0845 641 9350

0845 641 9355

1

Scotland Region 0845 641 9330

Western Region 0845 641 9320

REYQ8P8 model at 50% cooling – 50% heating load in conditions: outdoor temperature 11° CDB, indoor temperature: 18° CWB, 22°CDB

132 2515_BOOK_VRV_2011.indb 132

24/03/2011 12:23


REY(H)Q-P

VRV III inverter heat recovery high COP combination ®

REYHQ24P

• Only those areas calling for air conditioning need to be cooled or heated and the system can be shut down completely in unoccupied rooms • Quick cool/heat change over • Improved refrigerant containment check • Extra low noise during night time operation (step 1: 50dBA; step 2: 45dBA) • Possibility to extend the operation range in cooling down to -20°C

• Heat recovery operation can provide energy efficiency levels in excess of 9.0 • Top energy efficiency in Daikin heat recovery range, with high rate of ECA qualification • Wide range of indoor units: 13 different models in a total of 75 variations • Continuous heating during defrost (resulting in a higher integrated heating capacity) • Easy installation thanks to automatic refrigerant charging operation, automatic test operation • Increased piping flexibility: maximum piping length: 165m, increased total piping length: 1,000m • The ability to control each conditioned zone keeps VRV®III system running costs to an absolute minimum

COP

4.5 4.4 4.3 4.2 4.1 4 3.9 3.8

8

10

12

16

18

20

22

24

HP

COP – Daikin Hi COP VRV COP – Other leading brand Hi COP VRV

heat RECOVERY Outdoor units Independent unit Capacity range Capacity Power Input (Nominal) EER COP Dimensions Weight Sound Level Operation Range Refrigerant Power Supply Piping connections

INVERTER

Outdoor Unit Outdoor Unit Cooling Heating Cooling Heating Cooling Heating (Height x Width x Depth) Unit Sound Power Cooling Sound Pressure Cooling Cooling Min~Max Heating Min~Max

Liquid (OD) Gas Max total length Max n° of indoor units to be connected

HP kW kW kW kW

mm kg dBA dBA °CDB °CWB

8 REYQ8P8 REYQ8P8 8 22.4 25.0 5.20 5.71 4.31 4.38

10 REYQ10P8 REYQ10P8 10 28.0 31.5 7.09 7.38 3.95 4.27 1,680 x 1,300 x 765

12 REYQ12P8 REYQ12P8 12 33.5 37.5 8.72 8.84 3.84 4.24

16 REMQ8P9 REMQ8P9Y1B 16 45.0 50.0 10.5 11.5 4.29 4.36

18 REMQ8P9 REMQ10P9 18 50.4 56.5 12.7 13.4 3.98 4.22

20 REMQ8P9 REMQ12P9 20 56.0 62.5 13.9 14.3 4.04 4.36 85 64

331 78

78

80

82

81

58

58

60

62

61

22 REMQ10P8 REMHQ12P8 22 61.5 69.0 16.0 16.3 3.84 4.24

24 REMHQ12P8 REMHQ12P8 24 67.0 75.0 17.2 17.2 3.89 4.37

85 64

87 66

-5.0~43.0 -20.0~15.0 R-410A 3~/380-415V/50Hz

3~/400V/50Hz 12.7

mm mm m

15.9 28.6

-

26

34.9 1000 32

35

39

133 2515_BOOK_VRV_2011.indb 133

24/03/2011 12:23


REYQ-P8/P9

VRV III heat recovery compact combination ®

REYQ46-48P8Y1B

• Increased EER/COP thanks to the redesigned 8 and 12HP stand alone units and 8HP modular unit • Its operation range for example 8hp to 48hp in 2hp increment steps (21 system combinations), is wider than any of its contemporaries • Its ability to run no less than 64 indoor units in heat recovery format cannot at present be matched by other comparable systems • Continuous heating during defrost (resulting in a higher integrated heating capacity) • Easy installation thanks to automatic refrigerant charging operation, automatic test operation • Increased piping flexibility: maximum piping length: 165m, increased total piping length: 1,000m • The ability to control each conditioned zone keeps VRV®III system running costs to an absolute minimum • Only those areas calling for air conditioning need to be cooled or heated and the system can be shut down completely in unoccupied rooms

REYQ-P8

8

REYQ8P9 REYQ10P8 REYQ12P9 REYQ14P8 REYQ16P8 REMQ8P9 Modular units REMQ10P8 REMQ12P8 REMQ14P8 REMQ16P8 Number of outdoor units

1

1

REYQ-P8

30

Stand alone units

REYQ8P9 REYQ10P8 REYQ12P9 REYQ14P8 REYQ16P8 REMQ8P9 Modular units REMQ10P8 REMQ12P8 REMQ14P8 REMQ16P8 Number of outdoor units

10

12

14

• Quick cool/heat change over • Improved refrigerant containment check function • Flexible combination of outdoor units: Small footprint combination, high COP combination or any other combination of your choice

16

18

20

22

24

26

28

1 Not Applicable

1 1 1 1 1

1

Not Applicable

1

1

32

1

34

1

2

38

36

40

1

1 1

2

2

2

2

42

1

44

1 1 2

1 2

46

48

1 2 3

3 3

Stand alone units

Not Applicable

1 1 1 1 2

2 2

1 3

1 1

1 1

2

1

1 3

1 3

1 3

1 2 3

2 3

134 2515_BOOK_VRV_2011.indb 134

24/03/2011 12:23


REYQ-P8/P9 VRV®III heat recovery

heat recovery REYQ-P8 Capacity range Capacity Power Input (Nominal) EER COP Dimensions Weight Sound Level Operation Range

Cooling Heating Cooling Heating

(Height x Width x Depth) Sound Power Sound Pressure Cooling Heating

8 8 22.4 25.0 5.20 5.71 4.31 4.38

10 10 28.0 31.5 7.09 7.38 3.95 4.27

78 58

331 78 58

9.52 / 19.1

9.52 / 22.2

HP kW kW kW kW

Cooling Cooling Min~Max Min~Max

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas Max Total Length

mm kg dBA dBA o CDD o CWB

mm m

12 12 33.5 37.5 8.72 8.84 3.84 4.24 1,680x1,300x765

14 14 40.0 45.0 11.4 11.0 3.51 4.09

80 60 -5~43 -20~15 R-410A 3~/380-415V/50Hz -

83 62

16 16 45.0 50.0 14.1 12.8 3.19 3.91 339 84 63

12.7 / 28.6 1000

heat recovery REYQ-P8 Capacity range Capacity Power Input (Nominal) EER COP Dimensions Weight Sound Level Operation Range

HP kW kW kW kW

Cooling Heating Cooling Heating

(Height x Width x Depth) Sound Power Sound Pressure Cooling Heating

Cooling Cooling Min~Max Min~Max

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas Max Total Length

mm kg dBA dBA o CDD o CWB

18 18 50.4 56.5 12.7 13.4 3.98 4.22

20 22 20 22 55.9 61.5 62.5 69.0 14.9 17.0 15.2 17.1 3.76 3.62 4.11 4.04 1,680x930 + 930x765 204 + 254

81 61

254 + 254 83 62

83 63

15.9 / 28.6

mm m

24 24 67.0 75.0 19.2 18.9 3.49 3.97

83 63

26 28 26 28 73.0 78.5 81.5 87.5 21.6 23.8 20.6 22.3 3.38 3.30 3.96 3.92 1,680x930 + 1,240x765 254 + 334 83 83 63 63

-5~43 -20~15 R-410A 3~/380-415V/50Hz 15.9 / 34.9 1000

30 32 30 32 85.0 90.0 95.0 100.0 26.6 28.4 24.2 25.8 3.20 3.17 3.93 3.88 1,680x1,240 + 1,240x765 334 + 334 83 83 63 63

19.1 / 34.9

heat recovery REYQ-P8 Capacity range Capacity Power Input (Nominal) EER COP Dimensions Weight Sound Level Operation Range

HP kW kW kW kW

Cooling Heating Cooling Heating

(Height x Width x Depth) Sound Power Sound Pressure Cooling Heating

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas Max Total Length

Cooling Cooling Min~Max Min~Max

mm kg dBA dBA o CDD o CWB

mm m

34 34 95.4 107.0 26.9 26.3 3.55 4.07

36 38 40 36 38 40 101.0 107.0 112.0 113.0 119.0 125.0 29.1 31.2 33.4 28.1 30.0 31.8 3.47 3.43 3.35 4.02 3.97 3.93 1,680x930 + 930 + 1,240x765 204 + 254 + 334 254 + 254 + 334 84 85 85 85 64 64 65 65

42 44 42 44 118.0 124.0 132.0 138.0 35.8 38.0 33.5 35.2 3.30 3.26 3.94 3.92 1,680x930 + 1,240 + 1,240x765 254 + 334 + 334 85 85 65 65

46 48 46 48 130.0 135.0 145.0 150.0 40.8 42.6 37.1 38.7 3.19 3.17 3.91 3.88 1,680x1,240 + 1,240 + 1,240x765 334 + 334 + 334 85 85 65 65

-5~43 -20~15 R-410A 3~/380-415V/50Hz 19.1 / 41.3 1000

19.1 / 34.9

135 2515_BOOK_VRV_2011.indb 135

24/03/2011 12:23


BSVQ-P8

Individual branch selector for VRV® heat recovery

BSV4/6Q-PV

Multi branch selector for VRV® heat recovery

BSVQ100P8

BSVQ-P8 • High comfort levels: individual control and change over of 1 group of indoor units • Maximum design flexibility because individual and multi boxes can be combined in one system • Low built-in height • No drain piping needed • Allows multi tenant applications (option PCB required)

Maximum capacity index of connectable indoor units

BSVQ100P8

BSVQ160P8

20 < x ≤ 100

100 < x ≤ 160

Maximum number of connectable indoor units Power input Dimensions

160 < x ≤ 250

5

8

Cooling

kW

Heating

kW

0.005

(Height x Width x Depth)

mm

207 x 388 x 326

Weight Piping connections

BSVQ250P8

0.005

kg Outdoor unit

Liquid / gas / discharge gas

Type ∅ mm

Indoor unit

Liquid / gas

Type ∅ mm

12

15 Brazing connection

9.52 / 15.9 / 12.7

9.52 / 22.2 / 19.1 Brazing connection

9.52 / 15.9

Power Supply

9.52 / 22.2 1~/220-240V/50Hz

BSV4/6Q-PV • Rapid installation resulting from less brazing points and wiring • High comfort levels: individual control and change over of up to 4 or 6 groups of indoor units • Maximum design flexibility because individual and multi boxes can be combined in one system • Low built-in height • No drain piping needed

BSV4Q100PV

BSV4Q100PV Maximum capacity index of connectable indoor units

BSV6Q100PV

400

Maximum capacity index of connectable indoor units per branch

600 100

Number of branches

4

6

Maximum number of connectable indoor units

20

30

Maximum number of connectable indoor units per branch Power input Dimensions

kW

0.020

Heating

kW

0.020

0.030

(Height x Width x Depth)

mm

209 x 1,053 x 635

209 x 1,577 x 635

kg

60

Weight Piping connections

5

Cooling

Outdoor unit

Liquid / gas / discharge gas

Type ∅ mm

Indoor unit

Liquid / gas

Type ∅ mm

0.030

89 Brazing connection

12.7 x 28.6 x 19.1

15.9 x 28.6 x 28.6 Brazing connection 9.5 / 15.9

Power Supply

1~/220-240V/50Hz

136 2515_BOOK_VRV_2011.indb 136

24/03/2011 12:24


RXHQ-P

VRV®III heating only

RXHQ44-46-48P

• Compact size leaves maximum floor space • High external static pressure (up to 78.4Pa) allows indoor installation • Wide piping flexibility: maximum piping length: 165m, total piping length: 1,000m • All indoor units can be individually controlled • Phased installation possible

• Cost effective, low energy consumption heating system • Lower CO2 emissions compared to traditional heating systems • Easy installation thanks to automatic refrigerant charging and automatic testing • Easy compliance with F-gas regulation thanks to automated refrigerant containment check • Flexible combination of outdoor units

INVERTER

Heating only Outdoor system Capacity range Heating capacity Nom. Power input - 50Hz Heating Nom. COP Maximum number of connectable indoor units Dimensions Unit HeightxWidthxDepth Weight Unit Operation range Heating Min.~Max. Refrigerant Type Piping connections Liquid OD Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase / Frequency / Voltage Outdoor system System Outdoor unit module 1 Outdoor unit module 2 Capacity range Heating capacity Nom. Power input - 50Hz Heating Nom. COP Maximum number of connectable indoor units Operation range Heating Min.~Max. Refrigerant Type Piping connections Liquid OD Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase / Frequency / Voltage Outdoor system System Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3 Capacity range Heating capacity Nom. Power input - 50Hz Heating Nom. COP Maximum number of connectable indoor units Operation range Heating Min.~Max. Refrigerant Type Piping connections Liquid OD Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase / Frequency / Voltage

HP kW kW

mm kg °CWB mm mm m m Hz / V

8 8 25.0 5.56 4.5 17 187

12 12 37.5 9.44 3.97 26

16 16 50.0 12.90 3.88 34 1,680x1,240x765

18 18 56.5 15.30 3.69 39

316

324

-20.0~15.0 R-410A 9.5 19.1

22.2

12.7 28.6

12.7

15.9 28.6

1,000 50 (outdoor unit in highest position) (optional: 90) 3N~ / 50 / 400 22 RXHQ10P RXHQ12P 22 69.00 17.08 4.04 47

20 62.50 14.95 4.18 43

24 RXHQ12P

26 RXHQ8P

28 RXHQ10P

24 75.00 18.89 3.97 52

26 81.50 20.69 3.94 56

28 88.00 22.98 3.83 60 -20.0~15.0 R-410A

°CWB mm mm m m Hz / V

HP kW kW

14 14 45.0 11.30 3.98 30

240

20 RXHQ8P HP kW kW

10 10 31.5 7.70 4.09 21 1,680x930x765

30 32 RXHQ12P RXHQ14P RXHQ18P 30 32 94.00 102.00 24.67 26.63 3.81 3.83

34 RXHQ16P

36 RXHQ18P

34 107.00 28.23 3.79

36 113.00 30.62 3.69

64

15.9

19.1

28.6

34.9

41.3

1,000 50 (outdoor unit in highest position) (optional: 90) 3N~ / 50 / 400 38 RXHQ8P

40 RXHQ10P RXHQ12P

42 RXHQ12P

38 119.00 30.13 3.95

40 126.00 32.39 3.89

42 132.00 34.20 3.86

°CWB mm mm m m Hz / V

44 RXHQ8P

46 RXHQ10P

48 50 RXHQ12P RXHQ14P RXHQ18P

RXHQ18P 46 48 145.00 151.00 38.26 39.95 3.79 3.78 64 -20.0~15.0 R-410A 19.1 41.3 1,000 50 (outdoor unit in highest position) (optional: 90) 3N~ / 50 / 400 44 138.00 35.94 3.84

50 158.00 41.91 3.77

52 RXHQ16P

54 RXHQ18P

52 163.00 43.47 3.75

54 170.00 45.95 3.70

137 2515_BOOK_VRV_2011.indb 137

24/03/2011 12:24


RXYHQ-P9

VRV III inverter heat pump high COP combination ®

• Connectable to current Daikin control systems: DS-net, Intelligent Touch Controller, Intelligent Manager, BACnet Gateway, DMS-IF • Easy installation thanks to automatic refrigerant charging operation, automatic test operation • Refrigerant containment check function

• Top energy efficiency in Daikin heat pump range, thanks to the redesigned 8HP unit and newly developed 12HP high COP unit • Wide range of indoor units: 13 different models in a total of 75 variations • Compact size of outdoor units • Increased external static pressure: up to 78.4Pa • 2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st step: 54dBA, 2nd step: 45dBA • RoHS compliant • Easy combination with HRV

4.60 4.50 4.40

+ 13%

4.30

COP

4.20 4.10 4.00 3.90 3.80 3.70 12

16

18

20

22

24

26

28

30

32

34

36

New high COP range previous high COP range

RXYQ-P9 Modules

12 RXYQ8P9 RXYQ10P9 RXYHQ12P9

16

18

20

2

1 1

1

1

22

1

1 1

heat pump Outdoor Units Capacity range Capacity Power input (nominal) EER COP Dimensions Sound Level Operation Range

26

28

30

32

3

2 1

1 2

1 1 1

1

34

36

2

1 2

3

28 28 78.4 88.0 19.0 19.8 4.12 4.44

30 30 84.0 94.5 21.2 21.9 3.96 4.31

32 32 89.4 100.0 22.4 22.7 3.99 4.40

34 34 95.0 107.0 24.7 24.9 3.85 4.79

36 36 101.0 113.0 25.9 25.9 3.89 4.37

83 63

83 63

85 64

85 64

85 65

45

48 19.1 / 34.9

52

55

58 19.1 / 41.3

INVERTER

Cooling Heating Cooling Heating

HP kW kW kW kW

(Height x Width x Depth) Sound Power Cooling Sound Pressure Cooling Cooling Min~Max Heating Min~Max

mm dBA dBA °CDB °CWB

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas Max total length

24

mm m

12 12 33.5 37.5 8.6 8.6 3.89 4.37

16 16 44.8 50.0 10.4 11.1 4.29 4.50

18 18 50.4 56.5 12.6 13.2 4.00 4.27

20 20 56.0 63.0 13.8 14.3 4.05 4.42

22 22 61.5 69.0 16.0 16.3 3.84 4.24

82 60

82 61

83 62

83 62

29

32 15.9 / 28.6

35

1680x1240x765

80 60

19 26 12.7 / 28.6 12.7 / 28.6

24 24 67.2 75.0 15.7 16.7 4.29 4.50

26 26 72.8 81.5 17.8 18.8 4.09 4.34 83 83 62 62 -5.0~43.0 -20.0~15.0 R-410A 3N~/400V/50Hz 39 42 15.9 / 34.9 1000

138 2515_BOOK_VRV_2011.indb 138

24/03/2011 12:24


RXYQ-P9

VRV III inverter heat pump small footprint combination ®

RXYQ44P8 RXYQ46-48P7

• Increased EER/COP thanks to the redesigned 8HP unit • Outdoor unit capacity up to 54 HP • Wide range of indoor units: 13 different models in a total of 75 variations • Flexible combination of outdoor units: small footprint combination, high COP combination or any other combination of your choice • Compact size of outdoor units • Increased external static pressure: up to 78.4Pa • 2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st step: 54dBA, 2nd step: 45dBA • RoHS compliant

RXYQ-P9

5

RXYQ5P9

1

8

10

• Easy combination with HRV • Connectable to current Daikin control systems: DS-net, Intelligent Touch Controller, Intelligent Manager, BACnet Gateway, DMS-IF • Easy installation thanks to automatic refrigerant charging operation, automatic test operation • Refrigerant containment check function

12

14

16

18

1

RXYQ8P9

26

28

30

1 1

1

1

1

1

2

1

1

RXYQ14P9

1

RXYQ16P9

1

1

RXYQ18P9

32

34

36

38

40

RXYQ5P9

42

44

46

48

50

1

1

52

54

Not applicable

1

RXYQ8P9

1 1

RXYQ10P9 1

RXYQ12P9

1

1 2

1

1

1 1

RXYQ16P9 RXYQ18P9

24

1

RXYQ12P9

RXYQ14P9

22

1

RXYQ10P9

RXYQ-P9

20

Not applicable

1

1

1 2

1

1

1

2

2

2

2

2

3

139 2515_BOOK_VRV_2011.indb 139

24/03/2011 12:24


RXYQ-P9

VRV III inverter heat pump small footprint combination ®

heat pump Outdoor units Capacity range Capacity Power input (nominal) EER COP Dimensions Weight Sound Level Operation Range

HP kW kW kW kW

Cooling Heating Cooling Heating

(Height x Width x Depth) Sound Power Sound Pressure Cooling Heating

Cooling Cooling Min~Max Min~Max

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas Max. total length

mm kg dBA dBA CDB CWD

mm m

5 5 14.0 16.0 3.52 4.00 3.98 4.00 1,680x635x765 159 72 54

8 8 22.4 25.0 5.22 5.56 4.29 4.50

10 10 28.0 31.5 7.42 7.70 3.77 4.09 1,680x930x765

187

12 12 33.5 37.5 9.62 9.44 3.48 3.97

14 14 40.0 45.0 12.4 11.30 3.23 3.98

240

316

78 57

8 9.52 / 15.9

16 9.52 / 22.2

-5.0~43.0 -20.0~15.0 R-410A 3N~/400V/50Hz 19

23 12.7 / 28.6

18 18 49.0 56.5 16.2 15.30 3.02 3.69 324 83 63

80 60

58

13 9.52 / 19.1

16 16 45.0 50.0 14.2 12.90 3.17 3.88 1,680x1,240x765

26

29 15.9 / 28.6

1000

heat pump Outdoor units Capacity range Capacity Power input (nominal) EER COP Dimensions Weight Sound Level Operation Range

HP kW kW kW kW

Cooling Heating Cooling Heating

(Height x Width x Depth) Sound Power Sound Pressure Cooling Heating

Cooling Cooling Min~Max Min~Max

mm kg dBA dBA CDB CWD

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas

mm

Max. total length

m

20 20 55.9 62.5 14.7 14.9 3.80 4.18

22 22 61.5 69.0 17.0 17.1 3.62 4.04

24 24 67.0 75.0 19.2 18.9 3.49 3.97

26 26 71.4 81.5 20.9 20.7 3.41 3.94

83 62

83 63

83 63

85 64

35

39 15.9 / 34.9

42

32 15.9 / 28.6

28 28 77.0 88.0 23.6 23.0 3.26 3.83 85 65 -5.0~43.0 -20.0~15.0 R-410A 3N~/400V/50Hz 45

30 30 82.5 94.0 25.8 24.7 3.20 3.81

32 32 89.0 102.0 28.6 26.6 3.11 3.83

34 34 94.0 107.0 30.4 28.2 3.09 3.79

36 36 98.0 113.0 32.4 30.6 3.02 3.69

85 65

85 65

85 65

86 66

49 19.1 / 34.9

52

55

58 19.1 / 41.3

48 48

50 50

52 52

54 54

132.0 151.0 42.0 40.0 3.14 3.78

138.0 158.0 44.8 41.9 3.08 3.77

143.0 163.0 46.6 43.5 3.07 3.75

147.0 170.0 48.6 45.9 3.02 3.70

87 67

87 67

87 67

88 68

1000

heat pump Outdoor units Capacity range Capacity Power input (nominal) EER COP Dimensions Weight Sound Level Operation Range

HP Cooling Heating Cooling Heating

kW kW kW kW

(Height x Width x Depth)

mm kg dBA dBA CDB CWD

Sound Power Sound Pressure Cooling Heating

Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas Max. total length

Cooling Cooling Min~Max Min~Max

38 38

40 40

42 42

44 44

105.0 119.0 30.6 30.1 3.43 3.95

111.0 126.0 33.2 32.4 3.34 3.89

116.0 132.0 35.4 34.2 3.28 3.86

120.0 138.0 36.9 35.9 3.25 3.84

86 66

86 66

86 66

87 67

61 mm m

46 46 126.0 145.0 39.8 38.3 3.17 3.79 87 67 -5.0~43.0 -20.0~15.0 R-410A 3N~/400V/50Hz 64 19.1/41.3 1000

140 2515_BOOK_VRV_2011.indb 140

24/03/2011 12:24


RXYRQ-P

VRV III heat pump with connection to stylish indoor units ®

FXSQ-P VRV® indoor unit FVXS-F

FTXG-J

BPMKS967B3

FTXS-G BPMKS967B2

FTXG-J FXFQ-P9 VRV® indoor unit

FVXG-K

BPMKS967B2

• Innovative VRV® technology combined with stylish and silent indoor units • Wide range of indoor units: combine VRV® indoor units and stylish indoor units as Daikin Emura and Nexura • Up to 39 indoor units can be connected to a 18HP unit • Integrate temperature control, fresh air provision, Biddle air curtains and the production of hot water in one total solution system • High external static pressure (up to 78.4Pa) allows indoor installation • Night quiet mode in two steps: step 1: 50 dBA, step 2: 45 dBA • All indoor units can be individually controlled • Phased installation possible

RXYRQ8-12P

CONNECTABLE INDOOR UNITS Daikin Emura - Wall mounted unit Wall mounted unit Nexura - Floor standing unit Floor standing unit Flexi type unit Slim concealed ceiling unit Concealed ceiling unit 4-way blow ceiling mounted cassette (600x600) Round flow cassette Ceiling suspended cassette All VRV® indoor units in all available classes

20 class

25 class

35 class

42 class

50 class

60 class

71 class

FTXS20J -

FTXG25JW/S FTXS25J FVXG25K FVXS25F FLXS25B FDXS25E FDBQ25B FFQ25BV -

FTXG35JW/S FTXS35J FVXG35K FVXS35F FLXS35B FDXS35E FBQ35C FFQ35BV FCQ35C8 FHQ35B

FTXS42J -

FTXG50JW/S FTXS50J FVXG50K FVXS50F FLXS50B FDXS50C FBQ50C FFQ50BV FCQ50C8 FHQ50B

FTXS60G FLXS60B FDXS60C FBQ60C FFQ60BV FCQ60C8 FHQ60B

FTXS71G -

Heat PUMP Outdoor units Capacity range Cooling capacity Heating capacity Power input - 50Hz

Nom. Nom. Cooling Heating

Nom. Nom.

EER COP Maximum number of connectable indoor units Sound power level Cooling Nom. Sound pressure level Cooling Nom. Operation range Cooling Min.~Max. Heating Min.~Max. Refrigerant Type Piping connections Liquid OD Gas OD Total piping length System Actual Level difference OU - IU Power supply Phase / Frequency / Voltage

Branch provider Max. n° of indoor units to be connected Max. indoor unit connectable capacity Dimensions Height x Width x Depth Weight

HP kW kW kW kW

dBA dBA °CDB °CWB mm mm m m Hz / V

kW mm kg

RXYRQ8P 8 22.4 25.0 5.22 5.56 4.29 4.50 17

RXYRQ10P 10 28.0 31.5 7.42 7.70 3.77 4.09 21

RXYRQ12P 12 33.5 37.5 9.62 9.44 3.48 3.97 26

RXYRQ14P 14 40.0 45.0 12.4 11.30 3.23 3.98 30 80 60

78 57

58

RXYRQ16P 16 45.0 50.0 14.2 12.90 3.17 3.88 34

RXYRQ18P 18 49.0 56.5 16.2 15.30 3.02 3.69 39 83 63

-5.0~43.0 -20.0~15.0 R-410A 9.52 19.1

12.7 22.2

15.9 28.6

135 40 (outdoor unit in highest position) 3N~ / 50 / 400

BPMKS967B2 2 14.2 (7.1 + 7.1)

BPMKS967B3 3 20.8 (6.0 + 7.1 + 7.1) 180 x 294 x 350

7.5

8

141 2515_BOOK_VRV_2011.indb 141

24/03/2011 12:24


RXYSQ-P8

VRV III-S inverter heat pump ®

• High COP values • Easy installation thanks to automatic refrigerant charging operation, automatic test operation • Wide range of indoor units • Power consumption limit setting • Small capacities - 4, 5 & 6HP • Slim & flexible design • Space saving outdoor unit

RXYSQ4-5-6PA7V(Y)1B

Heat Pump Outdoor Unit (Single Phase) Capacity range Capacity Cooling Heating Power Input (Nominal) Cooling Heating EER COP Dimensions (Height x Width x Depth) Weight Sound Level Sound Power Cooling Sound Pressure Cooling Heating Operation Range Cooling Min~Max Heating Min~Max Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas/Drain Max total length

HP kW kW kW kW

mm kg dBA dBA dBA °CDB °CWB

RXYSQ4P8V1 4 11.2 12.5 2.81 2.74 3.99 4.56

RXYSQ5P8V1 5 14.0 16.0 3.51 3.86 3.99 4.15 1,345x900x320 120 67 51 53 -5~46 -20~15.5 R-410A 1N~/220-240V/50Hz 8

66 50 52

6 mm m

9.52 / 15.9 / 26 x 3

RXYSQ6P8V1 6 15.5 18.0 4.53 4.57 3.42 3.94

69 53 55

9 9.52 / 19.1 / 26 x 3

300

Heat Pump Outdoor Unit (Three Phase) Capacity range Capacity Cooling Heating Power Input (Nominal) Cooling Heating EER COP Dimensions (Height x Width x Depth) Weight Sound Level Sound Power Cooling Sound Pressure Cooling Heating Operation Range Cooling Min~Max Heating Min~Max Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas/Drain Max total length

HP kW kW kW kW

mm kg dBA dBA dBA °CDB °CWB

RXYSQ4P8Y1 4 11.2 12.5 2.89 2.82 3.88 4.43

RXYSQ5P8Y1 5 14.0 16.0 3.61 3.97 3.88 4.03 1,345x900x320 120 67 51 53 -5~46 -20~15.5 R-410A 3N~/380-415V/50Hz 8

66 50 52

6 mm m

9.52 / 15.9 / 26 x 3

RXYSQ6P8Y1 6 15.5 18.0 4.65 4.69 3.33 3.83

69 53 55

9 9.52 / 19.1 / 26 x 3

300

142 2515_BOOK_VRV_2011.indb 142

24/03/2011 12:24


RWEYQ-P

Water cooled VRV® heat pump

• Wide condensing unit range: 10, 20 & 30HP via 1 single| refrigerant circuit • High COP values: 5.21 nominal value • Up to 32 indoor units connectable to a 30HP condensing unit • Wide range of indoor units: 13 different models in a total of 75 variations • Compact design 1000mm (H) x 780mm (W) x 550mm (D) • Operation range (inlet water temperature): 10-45°C • Connectable to current Daikin control systems: DS-net, Intelligent Touch Controller, Intelligent Manager, BACnet Gateway, DMS-IF • Flexible piping length

RWEYQ10MY1

Actual piping length between the VRV®-WII and indoor units: 120m (Equivalent piping length: 140m)

Water piping Refrigerant piping

(Total piping length: 300m)

Level difference between indoor units: 15m

g ipin al p m Actu h 120 t leng

Level difference between the VRV®-WII and indoor units: 50m if the VRV®-WII is above 40m if the VRV®-WII is below

VRV®-WII

ng pipi ent ival 140 m u q E th leng

Indoor installation

Water piping length depends on the heat source equipment

RWEYQ-P Modules

8 RWEYQ8P RWEYQ10P

10

1

16

18

2

1 1

1

20

24

26

28

30

3

2 1

1 2

3

26 71.5 81.5 15.1 14.5 4.74 5.62

28 75.8 88.0 16.6 16.3 4.57 5.40

30 80.1 94.5 18.1 18.2 4.43 5.19

2

heat PUMP Outdoor Units Capacity Power input (nominal) EER COP Dimensions

Cooling Heating Cooling Heating

Unit

kW kW kW kW

Height Width Depth

Weight Unit Sound pressure (nominal) Cooling Inlet water temperature Cooling Min~Max Heating Min~Max Refrigerant Power supply Piping connections Liquid (OD) Gas Discharge gas Max total length Max n° of indoor units to be connected

mm mm mm kg dBA °C °C

mm mm mm m

10 26.7 31.5 6.03 6.05 4.43 5.21

8 22.4 25.0 4.55 4.24 4.92 5.90

16 44.8 50.0 9.10 8.48 4.92 5.90

780

18 49.1 56.5 10.6 10.3 4.63 5.49

20 53.4 63.0 12.1 12.1 4.41 5.21 1,000

24 67.2 75.0 13.7 12.7 4.91 5.91

780+780

780+780+780 550

149

150 51

50

9.52 19.1 13

149+149 53

150+149

16

149+149+149 150+149+149 150+150+149 150+150+150 55 56

10~45 10~45 R-410A 3~/400V/50Hz 15.9 -

12.7 22.2

150+150 54

19.1

28.6 26

29

34.9 300 32

36

36

36

36

143 2515_BOOK_VRV_2011.indb 143

24/03/2011 12:24


RWEYQ-P

Water cooled VRV® heat recovery

• Wide condensing unit range: 10, 20 & 30HP via 1 single refrigerant circuit • High COP values: 5.21 nominal value • Up to 32 indoor units connectable to a 30HP condensing unit • Wide range of indoor units: 13 different models in a total of 75 variations • Compact design 1000mm (H) x 780mm (W) x 550mm (D) • Operation range (inlet water temperature): 10-45°C • Connectable to current Daikin control systems: DS-net, Intelligent Touch Controller, Intelligent Manager, BACnet Gateway, DMS-IF • Flexible piping length

Stacked configuration is possible.

RWEYQ10MY1

Ceiling height

3,200mm or higher

Floor level 100-300mm

RWEYQ-P Modules

8 RWEYQ8P RWEYQ10P

10

1

16

18

2

1 1

1

20

24

26

28

30

3

2 1

1 2

3

26 71.5 81.5 15.1 14.5 4.74 5.62

28 75.8 88.0 16.6 16.3 4.57 5.40

30 80.1 94.5 18.1 18.2 4.43 5.19

2

heat RECOVERY Outdoor Units Capacity Power input (nominal) EER COP Dimensions

Cooling Heating Cooling Heating

Unit

kW kW kW kW

Height Width Depth

Weight Unit Sound pressure (nominal) Cooling Inlet water temperature Cooling Min~Max Heating Min~Max Refrigerant Power supply Piping connections Liquid (OD) Gas Discharge gas Max total length Max n° of indoor units to be connected

10 26.7 31.5 6.03 6.05 4.43 5.21

8 22.4 25.0 4.55 4.24 4.92 5.90

mm mm mm kg dBA °C °C

149

mm mm mm m

19.1 15.9

22.2 19.1

13

16

16 44.8 50.0 9.10 8.48 4.92 5.90

780

18 49.1 56.5 10.6 10.3 4.63 5.49

20 53.4 63.0 12.1 12.1 4.41 5.21 1,000

24 67.2 75.0 13.7 12.7 4.91 5.91

780+780

780+780+780 550

150 51

50

9.52

149+149 53

150+149

150+150 54

149+149+149 150+149+149 150+150+149 150+150+150 55 56

10~45 10~45 R-410A 3~/400V/50Hz 15.9

12.7

19.1

28.6 22.2 26

29

34.9 28.6 300 32

36

36

36

36

144 2515_BOOK_VRV_2011.indb 144

24/03/2011 12:24


RWEYQ-PR

Geothermal application VRV®III water cooled inverter heat pump

• Heating with ground sourced water as a renewable energy source! - Groundwater remains at a relatively constant temperature during the year - Superior efficiency remains even at extreme outdoor temperatures - Uses renewable energy: ground water, water from a lake, water from rivers • Extension of the operation range down to -10°C in heating - Add ethylene glycol to the water when the water inlet temperature is lower than 5°C - No multi combinations possible - Heat Pump and Heat Recovery systems

RWEYQ10PR

heat PUMP and heat RECOVERY Outdoor Units Independent Unit Capacity Dimensions

Outdoor Unit Cooling Heating Unit

Height Width Depth

Weight Unit Sound Pressure (Nominal) Cooling Inlet Water Temperature Cooling Heating Refrigerant Power Supply Piping connections Liquid (OD) HP / HR Gas HP / HR Discharge gas HP / HR Max total length Max n° of indoor units to be connected

INVERTER kW kW mm mm mm kg dBA °C °C

mm mm mm m

10 RWEYQ10PY1R 26.7 31.5

8 RWEYQ8PY1R 22.4 25.0 1,000 780 550

149

150 51

50

10~45 -10~45 R-410A 3~/400V/50Hz 9.52 / 9.52 - / 19.1 19.1 / 15.9

- / 22.2 22.2 / 19.1 300

13

16

145 2515_BOOK_VRV_2011.indb 145

24/03/2011 12:24


FXFQ-P9

Round flow cassette

BRC1E51

FXFQ-P9

BRC7F532

• Fresh air intake: standard knockout and optional kit • Reduced installation height: 214mm for class 20-63 • Drain-up pump with 850mm lift fitted as standard

• Modern style decoration panel in pure white with grey louvres. Also available in white with white louvres • 360° air discharge ensures uniform air flow and temperature distribution • Air discharge from the corners avoids dead zones that may be subject to temperature differences • Comfortable horizontal air discharge ensures draught free operation and prevents ceiling soiling • 23 different air flow patterns possible • Allows multi tenant applications (option PCB required)

850 mm

• Optional daily self-cleaning filter available • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

Examples of air flow patterns possible

FXFQ-P9 Indoor units Capacity Power input Dimensions Weight Air flow rate Sound power (nominal) Sound pressure Refrigerant Power supply Piping connections Decoration panel

1

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Heating Cooling Cooling Heating

High/Low High/Low High/Low High/Low

Liquid (OD)/Gas/Drain (OD) Model Colour HeightxWidthxDepth Weight

kW kW kW kW mm kg m³/min m³/min dBA dBA dBA

mm

mm kg

20 2.20 2.50

25 2.80 3.20 0.053 0.045

32 3.60 4.00

40 4.50 5.00 0.063 0.055 204x840x840

20 12.5 / 9.0 12.5 / 9.0 49.0 31.0 / 28.0 31.0 / 28.0

13.5 / 9.0 13.5 / 9.0 50.0 32.0 / 28.0 32.0 / 28.0

50 5.60 6.30 0.083 0.067 21 15.5 / 10.0 15.0 / 9.5 51.0 33.0 / 28.0 33.0 / 28.0 R-410A 1~/220-240V/50Hz

63 7.10 8.00 0.095 0.114

16.5 / 11.0 17.5 / 12.0 52.0 34.0 / 29.0 36.0 / 30.0

6.40 / 12.7 / 32 BYCQ140CW11 / BYCQ140CW1W 2 / BYCQ140CGW13 Pure white (RAL 9010) 50x950x950 / 50x950x950 / 130x950x950 5.5 / 5.5 / 11.5

80 100 9.00 11.20 10.00 12.50 0.120 0.173 0.108 0.176 246x840x840 24 23.5 / 14.5 26.5 / 17.0 23.5 / 14.5 28.0 / 17.5 55.0 58.0 38.0 / 32.0 41.0 / 33.0 38.0 / 32.0 42.0 / 34.0

125 14.00 16.00 0.258 0.246 288x840x840 26 33.0 / 20.0 33.0 / 20.0 61.0 44.0 / 34.0 44.0 / 34.0

9.5 / 15.9 / 32

Pure white standard panel with grey louvres; 2 Pure white standard panel with white louvres; 3 Pure white auto cleaning panel

146 2515_BOOK_VRV_2011.indb 146

24/03/2011 12:24


FXZQ-M9

4-way blow ceiling mounted cassette (600mmx600mm)

BRC1E51

• Extremely compact casing (575mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles • 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices • Modern style decoration panel in white (RAL9010) • Low noise operation: down to 25 dBA sound pressure level • Excellent low draught characteristics • Vertical auto-swing function moves the discharge flaps up and down for efficient air distribution throughout the room • Since the flaps can move to a 0 degree position, virtually no draught can be experienced

FXZQ-M9

BRC7E530

• Drain up pump with 750mm lift fitted as standard • Allows multi tenant applications (option PCB required) • 5 different air flow patterns: Any one of 5 air flow patterns can be freely selected between zero and 40 degrees and will then be maintained during the operational cycle of the air conditioner • Air can be discharged in any of 4 directions • Possibility to shut 1 or 2 flaps for easy installation in corners • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

Examples of air flow patterns possible 2-way blow

4-way blow

3-way blow

FXZQ-M9 Indoor units Capacity Power input Dimensions Weight Air flow rate Sound power (nominal) Sound pressure Refrigerant Power supply Piping connections Decoration panel

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Cooling Cooling

High/Low High/Low

Liquid (OD)/Gas/Drain (OD) Model Colour HeightxWidthxDepth Weight

kW kW kW kW mm kg m³/min dBA dBA

mm

mm kg

15 1.50 1.70 286x575x575 18 8.1/7 29/25 R-410A 1~/220-240V/50Hz 6.4 / 12.7 / 36 BYFQ60B7W1 White (Ral 9010) 55x700x700 2.7

20 2.20 2.50

25 2.80 3.20 0.073 0.064

9.00 / 7.00 47.0 30.0 / 25.0

32 3.60 4.00 0.076 0.068 286x575x575 18 9.50 / 7.50 49.0 32.0 / 26.0 R-410A 1~/220-240V/50Hz 6.4 / 12.7 / 36 BYFQ60B7W1 White (Ral 9010) 55x700x700 2.7

40 4.50 5.00 0.089 0.080

50 5.60 6.30 0.115 0.107

11.00 / 8.00 53.0 36.0 / 28.0

14.00 / 10.00 58.0 41.0 / 33.0

* Note: grey cells contain preliminary data

147 2515_BOOK_VRV_2011.indb 147

24/03/2011 12:24


FXCQ-M8

2-way blow ceiling mounted cassette

BRC1E51

BRC7C62

FXCQ20,25,32M8

• Compact dimensions, can easily be mounted in a ceiling void of only 355mm

355mm • Auto-swing function ensures efficient air and temperature distribution and prevents ceiling soiling • Drain up pump with 600mm lift fitted as standard • Leaves maximum floor and wall space for furniture, decorations and fittings • Easy to clean flat suction grille • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXCQ-M8 Indoor Units Capacity Power input Dimensions Weight Air flow rate Sound power (nominal) Sound pressure Refrigerant Power supply Piping connections Decoration panel

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Heating Cooling Cooling Heating

High/Low High/Low High/Low High/Low

Liquid (OD)/Gas/Drain Model Colour HeightxWidthxDepth Weight

kW kW kW kW mm kg m³/min m³/min dBA dBA dBA

20 2.20 2.50 0.077 0.044

7.0 / 5.0 7.0 / 5.0 45.0 33.0 / 28.0 33.0 / 28.0

25 2.80 3.20

32 3.60 4.00

0.092 0.059 305x780x600 26 9.0 / 6.5 9.0 / 6.5

50 5.60 6.30 0.130 0.097 305x995x600

31

32 12.0 / 9.0 12.0 / 9.0

50.0 35.0 / 29.0 35.0 / 29.0

mm

35.5 / 30.5 35.5 / 30.5 R-410A 1~/230V/50Hz

63 7.10 8.00 0.161 0.126 305x1,180x600 35 16.5 / 13.0 16.5 / 13.0 52.0 38.0 / 33.0 38.0 / 33.0

6.35 / 12.7 / 32 BYBC32GJW1

mm kg

40 4.50 5.00

BYBC50GJW1 White (10Y9/0.5) 53x1245x680 8.5

53x1030x680 8.0

80 125 9.00 14.00 10.00 16.00 0.209 0.256 0.176 0.223 305x1,670x600 47 48 26.0 / 21.0 33.0 / 25.0 26.0 / 21.0 33.0 / 25.0 54.0 60.0 40.0 / 35.0 45.0 / 39.0 40.0 / 35.0 45.0 / 39.0

BYBC63GJW1

9.5 / 15.9 / 32 BYBC125GJW1

53x1430x680 9.5

53x1920x680 12.0

148 2515_BOOK_VRV_2011.indb 148

24/03/2011 12:24


FXKQ-MA

Ceiling mounted corner cassette

BRC1E51

FXKQ63MA

BRC4C61

• Slim design 215mm height • Auto-swing function ensures efficient air and temperature distribution • Choice between 3 auto-swing positions for maximum comfort: standard, draught prevention, ceiling soiling prevention • Optimum air flow conditions are created by either downward air discharge or frontal air discharge (via optional grille) or a combination of both • Leaves maximum floor and wall space for furniture, decorations and fittings • Drain up pump with 500mm lift fitted as standard • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

Downward discharge

Frontal discharge

Closed decoration panel Combination

FXKQ-MA Indoor units Capacity Power input Dimensions Weight Air flow rate Sound pressure Refrigerant Power supply Piping connections Decoration panel

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Cooling

High/Low High/Low

kW kW kW kW mm kg m³/min dBA

FXKQ25MAVE 2.80 3.20

FXKQ32MAVE 3.60 4.00

FXKQ40MAVE 4.50 5.00 0.076 0.056

0.066 0.046 215x1,110x710 31 11.00 / 9.00 38.0 / 33.0

13.00 / 10.00 40.0 / 34.0

FXKQ63MAVE 7.10 8.00 0.105 0.085 215x1,310x710 34 18.00 / 15.00 42.0 / 37.0

R-410A 1~/220-240V/50Hz Liquid (OD)/Gas/Drain Model Colour HeightxWidthxDepth Weight

mm

6.4 / 12.7 / 32 BYK45FJW1

mm kg

70x1240x800 8.5

9.5 / 15.9 / 32 BYK71FJW1 White 70x1440x800 9.5

149 2515_BOOK_VRV_2011.indb 149

24/03/2011 12:24


FXDQ-M9

Concealed ceiling unit (small)

BRC1E51

BRC4C62

FXDQ20,25M9

• Designed for hotel bedrooms • Compact dimensions (230mm high & 652mm deep), can easily be mounted in a ceiling void • The air suction direction can be altered from rear to bottom suction • Air suction filter fitted as standard • For easy mounting, the drain pan can be located to the left or the right of the unit • Allows multi tenant application • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXDQ-M9 Indoor Units Capacity Power input Dimensions Weight Air Flow Rate Sound power (nominal) Sound Pressure Refrigerant Power Supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Heating Cooling Cooling Heating

High/Low High/Low High/Low High/Low

Liquid (OD)/Gas/Drain (OD)

kW kW kW kW mm kg m³/min m³/min dBA dBA dBA

20 2.20 2.50

25 2.80 3.20 0.050 0.050 230x502x652 17

6.70 / 5.20 6.70 / 5.20

7.40 / 5.80 7.40 / 5.80 50.0 37.0 / 32.0 37.0 / 32.0 R-410A 1~/230V/50Hz 6.4 / 12.7 / 27.2

mm

150 2515_BOOK_VRV_2011.indb 150

24/03/2011 12:24


FXDQ-P7

Slim concealed ceiling unit

BRC1E51

BRC4C65

FXDQ20-32P7

• Slim design for flexible installation • Compact dimensions, can easily be mounted in a ceiling void of only 240mm • 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices • Low noise: down to 29dBA sound pressure level • Adjustable external static pressure • Optional discharge flanger available • Drain up pump with 750mm lift fitted as standard • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

200mm

FXDQ-P7 Indoor Units Capacity Power input Dimensions Weight Air flow rate External static pressure Sound pressure Refrigerant Power supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling High/Standard Cooling

HH/H/L HH/H/L

Liquid (OD)/Gas/Drain (OD)

kW kW kW kW mm kg m³/min Pa dBA

mm

15 1.5 1.7 200x700x620 23.0 - / 7.5 / 6.5 29 / 28 / 27 R-410A 1~/220-240V/50Hz 6.4 / 12.7 / 26.0

20 2.20 2.50

25 2.80 3.20 0.086 0.067 200x700x620 23.0 8.0 / 7.2 / 6.4 30 / 10 33.0 / 31.0 / 29.0

32 3.60 4.00 0.089 0.070

40 4.50 5.00 0.160 0.147

50 5.60 6.30 0.165 0.152

200x900x620 27.0 28.0 10.5 / 9.5 / 8.5 12.5 / 11.0 / 10.0 44 / 15 34.0 / 32.0 / 30.0 35.0 / 33.0 / 31.0 R-410A 1~/220-240V/50Hz 6.4 / 12.7 / 26.0

63 7.10 8.00 0.181 0.168 200x1,100x620 31.0 16.50 / 14.5 / 13.00 36.0 / 34.0 / 32.0

9.5 / 15.9 / 26.0

* Note: grey cells contain preliminary data

151 2515_BOOK_VRV_2011.indb 151

24/03/2011 12:24


FXSQ-P

Concealed ceiling unit

BRC1E51

BRC4C65

• Reduction of power consumption of 20% (compared to FXSQ-M8 series) through use of new DC fan • Improved comfort thanks to 3-step airflow control • External static pressure up to 120 Pa facilitates the use with flexible ducts of varying lengths: ideal for shops and medium size offices • Possibility to change ESP through wired remote control allows optimisation of the supply air volume • Allows multi tenant applications (option PCB required) • Easy installation thanks to automatic air flow adjustment towards nominal air flow rate • Drain-up pump with 624mm lift fitted as standard • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXSQ20,25,32P

How does it work? • Installer calculates the total duct resistance to determine the required ESP • During test run, the unit will automatically select the correct fan curve (more than 8 fan curves available) guaranteeing the nominal AFR • Thanks to the high number of fan curves available, adjustments to duct work can be avoided, resulting in a quicker installation process Reduced installation time • After installation, it is possible that the actual duct resistance is lower than expected at the time of designing. As a consequence the air flow will be too high. With the automatic air flow adjustment function the unit can adapt its fan speed to a lower curve, so the air flow decreases • The air flow will always be within 10% of the rated air flow because of the amount of possible fan curves (more than 8 fan curves available per model) • Alternatively the installer can manually select a fan curve with the wired remote control

FXSQ-P7 Indoor units Capacity Power input Dimensions Weight Air flow rate External static pressure Sound power (nominal) Sound pressure Refrigerant Power supply Piping connections Decoration panel

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Heating High / Standard Cooling Cooling Heating

High/Low High/Low

High/Low High/Low

Liquid (OD)/Gas/Drain (OD) Model Colour HeightxWidthxDepth Weight

kW kW kW kW mm kg m³/min m³/min Pa dBA dBA dBA

20 2.20 2.50

25 2.80 3.20

0.073 0.073 300x550x700 23 9.00 / 6.50 9.00 / 6.50 70 / 30 55.0 32.0 / 26.0 32.0 / 26.0

mm

32 3.60 4.00 0.079 0.079

9.50 / 7.00 9.50 / 7.00 56.0 33.0 / 27.0 33.0 / 27.0

6.35 / 12.7 / 32 BYBS32DJW1

mm kg

55x650x500 3

40 50 63 80 100 125 4.50 5.60 7.10 9.00 11.20 14.00 5.00 6.30 8.00 10.00 12.50 16.00 0.192 0.192 0.142 0.163 0.247 0.303 0.192 0.192 0.142 0.163 0.247 0.303 300x700x700 300x1000x700 300x1400x700 26 35 46 16.00 / 11.00 13.50 / 16.00 25.00 / 20.00 32.00 / 23.00 39.00 / 28.00 16.00 / 11.00 13.50 / 16.00 25.00 / 20.00 32.00 / 23.00 39.00 / 28.00 100 / 30 100 / 40 120 / 40 120 / 50 63.0 59.0 63.0 61.0 66.0 37.0 / 29.0 37.0 / 30.0 38.0 / 32.0 40.0 / 33.0 37.0 / 29.0 37.0 / 30.0 38.0 / 32.0 40.0 / 33.0 R-410A 1~/220-240V/50Hz 9.5 / 15.9 / 32 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 White (10Y9/0,5) 55x800x500 55x1100x500 55x1500x500 3.5 4.5 6.5

140 16.00 18.00 0.261 0.249 47 46.00 / 32.00 46.00 / 32.00 140 / 50 67.00 42.00 / 34.00 42.00 / 34.00

152 2515_BOOK_VRV_2011.indb 152

24/03/2011 12:24


FXMQ-P7

Concealed ceiling unit (inverter fan)

BRC1E51

FXMQ40P7

BRC4C65

• Reduction of power consumption through use of new DC fan motor technology • Improved comfort thanks to 3-step airflow control • Compact height of 300mm, allows installation in narrow ceiling voids • Up to 200 Pa external static pressure allows extensive ductwork runs and flexible application • Possibility to change ESP through wired remote control allows optimisation of the supply air volume (changeable in 13 or 14 stages) • Built-in drain pump with 700mm lift fitted as standard • Allows multi tenant applications (option PCB required) • The air suction direction can be from bottom or rear • Standard air filter • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXMQ-P7 Indoor units Capacity Power input (Nominal) Dimensions Weight Air flow rate External static pressure Refrigerant Power supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling H/S/L

HH/H/L

kW kW kW kW mm kg m³/min Pa

40 4.50 5.00 0.194 0.182 300x700x700 28 16.0 / 13.0 / 11.0 160 / 100 / 30

50 5.60 6.30 0.215 0.203

18.0 / 16.5 / 15.0

63 7.10 8.00 0.23 0.218 300x1000x700 36 19.5 / 17.5 / 16.0

80 9.00 10.00 0.298 0.286

100 11.20 12.50 0.376 0.364

25.0 / 22.5 / 20.0 200 / 100 / 50

125 14.00 16.00 0.461 0.449

300x1400x700 46 32.0 / 27.0 / 23.0 39.0 / 33.0 / 28.0

R-410A 1~/220-240V/50Hz Liquid (OD)/Gas/Drain (OD)

mm

6.4 / 12.7 / 32

9.5 / 15.9 / 32

153 2515_BOOK_VRV_2011.indb 153

24/03/2011 12:24


FXMQ-MA

Concealed ceiling unit (large)

BRC1E51

FXMQ-MA

BRC4C62

Optional drain pump accessory

• Range of models 200-250 class • Up to 270 Pa external static pressure allows extensive ductwork runs and flexible application: ideal for use in large areas • Optional drain pump (accessory): housing the drain pump inside the unit has reduced the required installation space • Optional suction air filter plenums and filters • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display 470 mm and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

0 - 250 mm

Min. 530mm

470 mm 222 mm

FXMQ-ma Indoor units Capacity Power input (nominal) Dimensions Weight Air flow rate External static pressure Sound pressure Refrigerant Power supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling High/Low High / Standard Cooling High/Low

kW kW kW kW mm kg m³/min Pa dBA

Liquid (OD)/Gas/Drain (OD)

mm

200 22.40 25.00 1.294 1.294

250 28.00 31.50 1.465 1.465 470x1,380x1100 137

58.00 / 50.00 221 / 132

72.00 / 62.00 270 / 147 48.0 / 45.0 R-410A 1~/220-240V/50Hz

9.5 / 19.1 / PS1B

9.5 / 22.2 / PS1B

154 2515_BOOK_VRV_2011.indb 154

24/03/2011 12:24


FXAQ-P

Wall mounted unit

BRC1E51

BRC7E618

FXAQ40-63P

• Modern style flat front panel • Vertical auto-swing function moves the discharge flaps up and down for efficient air distribution throughout the room • 5 different discharge angles can be programmed via the remote control

• Both horizontal flaps and front panel can easily be removed and washed • All maintenance operations can be carried out from the front of the unit • Ideal for refurbishment projects • Allows multi tenant applications (option PCB required) • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXAQ-P Indoor units Capacity Power input (50Hz) Dimensions Weight Air flow rate Refrigerant Sound power Sound pressure Power supply Piping connections Casing colour

INVERTER Cooling Nominal Heating Nominal Cooling Nominal Heating Nominal (Height x Width x Depth) Cooling Cooling Cooling

HH/H/M/L Nominal HH/H/M/L

Liquid (OD)/Gas/Drain

kW kW kW kW mm kg m³/min dBA dBA mm

20 2.20 2.50 0.019 0.029

- / 7.5 / - / 4.5

25 2.80 3.20 0.028 0.034 290x795x238 11 -/8/-/5

32 3.60 4.00 0.030 0.035

40 4.50 5.00 0.020 0.020

- / 8.5 / - / 5.5

- / 12 / - / 9

50 5.60 6.30 0.033 0.039 290x1,050x238 14 - / 15 / - / 12

63 7.10 8.00 0.050 0.060

- / 19 / - / 14

- / 42 / - / 36

- / 46 / - / 39

R-410A - / 35 / - / 29

- / 36 / - / 29

- / 37 / - / 29 - / 39 / - / 34 1~/220-240V/50Hz 6.35 / 12.7 / VP13 (I.D. 13/O.D. 18) White (3.0Y8.5 / 0.5)

9.52/15.9/VP13 (I.D. 13/O.D. 18)

155 2515_BOOK_VRV_2011.indb 155

24/03/2011 12:24


FXHQ-MA Ceiling suspended unit

BRC1E51

BRC7E63

FXHQ32MA

• Air flow distribution for ceiling heights up to 3.8m without loss of capacity • Use of W-shaped Coanda flap enhances horizontal and vertical air circulation characteristics • Wider air discharge thanks to Coanda effect: up to 100 degrees

100° • Easy installation and maintenance • Long life filter fitted as standard • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXHQ-MA Indoor units Capacity Power input Dimensions Weight Air flow rate Sound pressure Refrigerant Power supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Cooling

High/Low High/Low

Liquid (OD)/Gas/Drain (OD)

kW kW kW kW mm kg m³/min dBA

32 3.60 4.00 0.111 0.111 195x960x680 24 12.00 / 10.00 36.0 / 31.0

mm

6.4 / 12.7 / 26

63 7.10 8.00 0.115 0.115 195x1,160x680 28 17.50 / 14.00 39.0 / 34.0 R-410A 1~/220-240V/50Hz

100 11.20 12.50 0.135 0.135 195x1,400x680 33 25.00 / 19.50 45.0 / 37.0

9.5 / 15.9 / 26

156 2515_BOOK_VRV_2011.indb 156

24/03/2011 12:24


FXUQ-MA

4-way blow ceiling suspended cassette

BRC1E51

• • • •

FXUQ71MA

BRC7C528

• Auto-swing function ensures efficient air and temperature distribution • Air flow distribution for ceiling heights up to 3.5m without loss of capacity • Air can be discharged at 5 different angles between 0 and 60 degrees • Air filter, drain pan and heat exchanger fin are mildew proof and anti-bacterial treated • Drain up pump with 500mm lift fitted as standard • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

Group control with other VRV indoor units possible 5m maximum distance between FXUQ unit and junction box Air can be discharged in any of 4 directions Possibility to shut 1 or 2 flaps for easy installation in corners

FXUQ-MA Indoor units Capacity Power input Dimensions Weight Air flow rate Sound power (nominal) Sound pressure

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Heating Cooling Cooling Heating

High/Low High/Low High/Low High/Low

Refrigerant Power supply Piping connections Liquid (OD)/Gas/Drain (OD) Combination with junction box

kW kW kW kW mm kg m³/min m³/min dBA dBA dBA

HxWxD

100 11.2 12.5

mm kg

125 14.0 14.0 0.289 0.269 230x895x895 31

BEVQ71MA

29.00 / 21.00 29.00 / 21.00 59.0 43.0 / 38.0 43.0 / 38.0 R-410A 1~/220-240V/50Hz 9.5 / 15.9 / 26 BEVQ100MA

71

100

mm

BEVQ-MA Dimensions Weight Casing Power supply

71 8.0 9.0 0.180 0.160 165x895x895 25 19.00 / 14.00 19.00 / 14.00 56.0 40.0 / 35.0 40.0 / 35.0

100x350x225 3.0 Galvanised steel plate 1~, 50Hz, 220-240V

3.0

VE

32.00 / 23.00 32.00 / 23.00 60.0 44.0 / 39.0 44.0 / 39.0

BEVQ125MA

125

3.5

157 2515_BOOK_VRV_2011.indb 157

24/03/2011 12:24


FXNQ-P

Concealed floor standing unit

BRC1E51

• • • •

BRC4C62

FXNQ20,25P

Ideal for installation beneath a window Long life filter fitted as standard Requires very little installation space, only 220mm depth The connecting port faces downward, eliminating the need to attach auxiliary piping

Connecting port

Refrigerant piping

FXNQ-P Indoor Units Capacity Power input Dimensions Weight Air flow rate Sound pressure Refrigerant Power supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Cooling

High/Low High/Low

Liquid (OD)/Gas/Drain (OD)

kW kW kW kW mm kg m³/min dBA

20 2.20 2.50

25 2.80 3.20 0.049 0.049 610x930x220 19 7.00 / 6.00 35.0 / 32.0

mm

32 3.60 4.00

40 4.50 5.00

0.090 0.090 610x1,070x220 23 8.00 / 6.00 11.00 / 8.50 38.0 / 33.0 R-410A 1~/220-240V/50Hz 6.4 / 12.7 / 21

50 5.60 6.30

63 7.10 8.00

0.110 0.110 610x1,350x220 27 14.00 / 11.00 16.00 / 12.00 39.0 / 34.0 40.0 / 35.0

9.5 / 15.9 / 21

158 2515_BOOK_VRV_2011.indb 158

24/03/2011 12:25


FXLQ-P

Floor standing unit

BRC1E51

BRC7C62

FXLQ20-25P

• New stylish modern casing: finished in RAL 9010 colour • Unit can be installed as free standing model by use of optional back plate • Ideal for installation beneath a window • The use of inverter type outdoor units results in an air conditioning system with a high energy efficiency • Home leave operation saves energy during absence • Requires very little installation space • Running the pipes from connections at the back, enables the unit to be wall mounted which in turn allows cleaning beneath the unit where dust tends to accumulate

• Wired remote control can easily be integrated in the unit • BRC1E51A – new wired controller: allows easy navigation through menu items, via a personalised display and minimal number of buttons. Provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 5 different actions per day possible

FXLQ-P Indoor Units Capacity Power input (50Hz) Dimensions Weight Air Flow Rate Refrigerant Sound Power Sound Pressure Power Supply Piping connections Casing colour

INVERTER Cooling Nominal Heating Nominal Cooling Nominal Heating Nominal (Height x Width x Depth) Cooling

HH/H/M/L

kW kW kW kW mm kg m³/min

Cooling Cooling

Nominal HH/H/M/L

dBA dBA

Liquid (OD)/Gas/Drain

20 2.20 2.50

25 2.80 3.20 0.049 0.049 600x1,000x232 27 -/7/-/6

- / 35 / - / 32

mm

32 3.60 4.00

40 4.50 5.00

0.090 0.090 600x1,140x232 32 -/8/-/6 - / 11 / - / 8.5 R-410A - / 38 / - / 33 1~/220-240V/50Hz 6.35 / 12.7 / 21 Pure white (RAL9010) + Iron grey (RAL7011)

50 5.60 6.30

63 7.10 8.00

0.110 0.110 600x1,420x232 38 - / 14/ - / 11 - / 16 / - / 12

- / 39 / - / 34

- / 40 / - / 35 9.52 / 15.9 / 21

159 2515_BOOK_VRV_2011.indb 159

24/03/2011 12:25


CYQ-DK-BN Biddle standard air curtain

CYQ-DK-F

NETWORK SOLUTION

• Connectable to VRV® heat recovery and heat pump • VRV® is among the first DX systems suitable for connection to air curtains • A payback period of less then 1.5 years compared to installing an electric air curtain • Provides virtually free air curtain heating via recovered heat from indoor units in cooling mode • Easy and quick to install at reduced costs since no additional water systems, boilers and gas connections are required • All year round comfort ensured by the constant discharge velocity and adjustable jet airflow width (European patent) • Maximum energy efficiency stemming from almost zero down flow turbulence, optimised air flow and the application of advanced discharge rectifier technology • Around 85% air separation efficiency, greatly reducing both heat loss and required indoor unit heating capacity

VRV®

BIDDLE STANDARD AIR CURTAIN

SMALL Indoor units Heating capacity Power input Delta T Casing Dimensions

Fan only Nom. Heating Nom. Inlet = room temperature Colour Height Unit F/C/R* Width Unit F/C/R* Depth Unit F/C/R*

Required ceiling void > Door height Favorable/normal/unfavorable conditions Door width Max. Weight Unit Fan - Air flow rate - Heating Refrigerant Type Sound pressure - Heating Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Voltage

kW kW kW K mm mm mm mm m m kg m³/h dBA mm

MEDIUM

CYQS150DK80*BN

CYQS200DK100*BN

CYQS250DK140*BN

CYQM100DK80*BN

9.0 0.35 0.35

11.6 0.46 0.46

16.2 0.58 0.58 16

1,500 / 1,500 / 1,548

2,000 / 2,000 / 2,048

2,500 / 2,500 / 2,548

9.2 0.37 0.37 17 BN: RAL9010 270 / 270 / 270 1,000 / 1,000 / 1,048 590 / 821 / 561 420

1.5 66 / 83 / 88 1,746

2.3 / 2.15 / 2.0 2.0 83 / 102 / 108 2,328

2.5 107 / 129 / 137 2,910

49

50

15

1.0 57 / 68 / 66 1,605 R-410A 50

CYQM150DK80*BN CYQM200DK100*BN CYQM250DK140*BN

11.0 0.56 0.56 14

13.4 0.75 0.75 13

19.9 0.94 0.94 15

1,500 / 1,500 / 1,548

2,000 / 2,000 / 2,048

2,500 / 2,500 / 2,548

2.5 / 2.4 / 2.3 1.5 2.0 73 / 88 / 93 94 / 111 / 117 2,408 3,210

51 51 9.52 / 19.0 9.52 / 16.0 Daikin wired remote control (BRC1E51A) 1~/230V/50Hz

9.52 / 16.0

V

2.5 108 / 136 / 144 4,013

53

54 9.52 / 19.0

LARGE Indoor units Heating capacity Power input Delta T Casing Dimensions

CYQL100DK125*BN Fan only Nom. Heating Nom. Inlet = room temperature Colour Height Unit F/C/R* Width Unit F/C/R* Depth Unit F/C/R*

Required ceiling void > Door height Favorable/normal/unfavorable conditions Door width Max. Weight Unit Fan - Air flow rate - Heating Refrigerant Type Sound pressure - Heating Piping connections Liquid (OD) / Gas Required accessories (should be ordered separately) Power supply Phase / Frequency / Voltage

kW kW kW K mm mm mm mm m m kg m³/h dBA mm

15.6 0.75 0.75

CYQL150DK200*BN

CYQL200DK250*BN

CYQL250DK250*BN

23.3 1.13 1.13

29.4 1.50 1.50 14

31.1 1.88 1.88 12

15 BN: RAL9010 370 / 370 / 370 1,000 / 1,000 / 1,048

1,500 / 1,500 / 1,548 2,000 / 2,000 / 2,048 774 / 1,105 / 745 520 3.0 / 2.75 / 2.5 1.5 2.0 100 / 118 / 141 126 / 151 / 155 4,650 6,200 R-410A 54 56 9.52 / 19.0 9.52 / 22.0 Daikin wired remote control (BRC1E51A) 1~/230V/50Hz

1.0 76 / 81 / 83 3,100 53 9.52 / 16.0

Hz / V

2,500 / 2,500 / 2,548

2.5 157 / 190 / 196 7,750 57 9.52 / 22.0

*F: Freehanging model, C: Cassette model, R: Recessed model

160 2515_BOOK_VRV_2011.indb 160

24/03/2011 12:25


Hot water module For VRV® heat recovery

Heating only hydrobox for VRV®

Ideally positioned for the commercial office sector Daikin UK now offers an energy efficient domestic hot water and heating solution for w.c. facilities, kitchens and staff break out areas. Hot water module The VRV®III hot water module provides an energy efficient means of producing hot water with a leaving temperature range of 25 to 80°C from recovered or recycled heat. To date, the primary operation of the VRV® heat recovery system has been to extract heat from areas being cooled and re-distribute to parts of the building with a heating requirement, often as a result of building orientation and diversity. However, if more heat is extracted than can be effectively re-used this surplus heat is generally dissipated to the atmosphere at the VRV® outdoor unit and subsequently the recovered energy is wasted and the system is not operating at its peak efficiency.

Using the surplus heat By using the hot water module with VRV®III heat recovery the surplus heat can be effectively used as renewable heat for the generation and storage of domestic hot water as well as for heating, via under floor circuits, fan coil units, and low temperature radiators. In combination the hot water module and the VRV®III heat recovery system means that less energy is wasted and the overall system efficiency is greatly improved, reducing running costs and reducing carbon emissions.

Hot water Use heat pump technology to produce hot water • Free hot water production possible • Possibility to connect to solar panels • P ossible applications: bathrooms, sinks, underfloor heating and radiators

For applications requiring either chilled water, different capacities and configurations, or connection to the full Heat Recovery range, please contact your local sales office for advice.

p to

u savE

17%

ed to r a p com s boiler a ga

• Hot water up to 80°C

161 Hot water module.indd 161

30/03/2011 19:24


HXHD125A

Heating only hydrobox for VRV®

Heating only hydrobox for VRV®

• VRV® plug & play, all necessary components integrated • Use heat pump technology to efficiently produce hot water, up to 17% savings compared to a gas boiler • Free hot water production possible by recovery of heat from areas requiring cooling • Leaving water temperature from 25 up to 80°C, without electric heater • Hot water production possible up to 35°C ambient outdoor temperature

• Possibility to connect thermal solar panels to the domestic hot water tank • Possible applications: bathrooms, sinks, under floor heating and radiators • No gas connection needed • Only connectable to REYAQ10-16P

Heating only Heating capacity Casing

Nom. Colour Material HeightxWidthxDepth

Dimensions Weight Refrigerant Sound pressure level (1) Sound pressure level (2) Sound pressure level (3) Heating operation Ambient range

Power supply Recommended fuses

Type

Minimum Maximum Waterside Minimum LW Maximum LW Phase / Frequency / Voltage

HXHD125A 14.0 Metallic Grey Pre coated sheet metal 705x600x695 92 R-134a / R-410A 40 43 38 -15 20 25 80 1~ / 50 / 220-240 20

kW

mm kg Cascade dBA dBA dBA °C °C °C °C Hz / V A

(1) Measuring conditions: Entering water: 55°C, leaving water: 65°C (3) Measuring conditions: Entering water: 55°C, leaving water: 65°C, low sound mode

(2) Measuring conditions: Entering water: 70°C, leaving water: 80°C Reversible hydrobox for VRV® (EKHBHV80,140BA) available on request.

OUTDOOR UNITS REYAQ-P Capacity

Dimensions Weight Heat exchanger Fan Air flow rate Fan Compressor Refrigerant

Piping connections Piping diameter Defrost method Power supply (±10%) Fuse Safety devices

Cooling (*1) EER Heating (*2) COP HeightxWidthxDepth Tube type Type Cooling Motor (drive) Output motor Motor type Name Charge Liquid (OD) / Gas / Discharge Gas Liquid (OD) / Gas / Discharge Gas

kW kW

10 28.0 3.95 31.5 4.27

mm kg

12 33.5 3.84 37.5 4.24

14 40.0 3.51 45.0 4.09

16 45.0 3.19 50.0 3.91

1680x1300x765 331

339 Cross finned coil Propeller

m³/min

190

210

235

240

Direct drive W

350x2

kg

(10.6)

mm

9.52 / 22.2 /19.1

Hz / V A

750x2 Hermetically sealed scroll compressor R-410A (10.8) (11.1) Braze connection 12.7 / 28.6 / 19.1 De-icer 3~ / 50 / 380-415

3~ / 25

(11.1) 12.7 / 28.6 / 22.2

3~ / 40 HPS Fan motor driver overload protector Over current relay Inverter overload protector

(*1) Rated cooling conditions: Outdoor temperature: 35°CDB, indoor unit: 27°C DB / 19 °C WB, equivalent refrigerant piping length: 5m, level difference: 0m. (*2) Rated heating conditions: Outdoor temperature: 7°C DB / 6°C WB, indoor unit: 20°C DB, equivalent refrigerant piping length: 5m, level difference: 0m.

162 HXHD125A.indd 162

30/03/2011 19:26


2515_BOOK_VRV_2011.indb 163

24/03/2011 12:25


Ventilation Air conditioning and air movement of course, are not the same. Neither actually includes the other but both are necessary components of a comfortable and energy efficient indoor climate.

Ventilation by itself cannot cope with the high heat gains generated by modern office complexes and indoor temperature and humidity levels can fluctuate wildly if ventilation alone is installed. On the other hand, air conditioning cannot supply the necessary fresh air needed for a balanced system. The ideal solution therefore, requires air conditioning and ventilation in combination.

Daikin manufactures and markets a range of fresh air reclaim, treatment and handling systems, carefully designed for integration with its air conditioning systems in order to achieve the most economic, environmentally conscious and best possible indoor comfort conditions.

1. Heat reclaim ventilation (HRV)

VAM-FA VKM-GA

165 166

2. Outdoor air processing unit

FXMQ-MF

167

3. Air handling applications

VRV Air handling application ERQ Air handling application VAP(W)-L Air handling units

168 169 171

For a copy of our latest Price List please call 0845 6419000

164 VentillationSubContents.indd 164

30/03/2011 19:33


VAM-FA

Heat reclaim ventilation

Clean outdoor air Total heat exchanged foul air

The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly. HRV units can be controlled individually or integral with the air conditioning system (Daikin VRV® or Sky Air series).

Foul indoor air

Total heat exchanged clean air

• 9 models to choose from • Compact, energy saving ventilation • Specially developed heat exchange element with HEP (High Efficiency Paper) • Easy integration into the VRV® system • Connectable to current Daikin control systems:

[iPU]

VAM-FA Ventilation Air flow rate Sound pressure level (max.) (1) External static pressure (max.) Temperature exchange efficiency Enthalpy exchange efficiency Dimensions

Weight Duct diameter Power supply

heating cooling H W D

m3/h dBA Pa % % % mm mm mm kg mm VE

VAM150FA8 VAM250FA8 VAM350FA8 VAM500FA8 VAM650FA8 VAM800FA8 VAM1000FA8 VAM1500FA8 VAM2000FA8 150 250 350 500 650 800 1,000 1,500 2,000 27/28.5 28/29 32/34 33/34.5 34.5/35.5 36/37 36/37 39.5/41.5 40/42.5 69 64 98 98 93 137 157 137 137 74 72 75 74 74 74 75 75 75 58 58 61 58 58 60 61 61 61 64 64 65 62 63 65 66 66 66 285 285 308 308 364 364 364 726 726 776 776 828 828 1,004 1,004 1,004 1,514 1,514 525 525 816 816 868 868 1,156 868 1,156 24 24 33 33 48 48 61 132 158 ø 100 ø 150 ø 150 ø 200 ø 200 ø 250 ø 250 ø 350 ø 350 1 ~, 50Hz, 220-240V

(1) Sound pressure level is measured in heat exchange mode.

165 2515_BOOK_Ventilation_2011.indb 165

21/03/2011 08:50


VKM-GA

Heat reclaim ventilation with DX coil

• Heat purge (economiser): heat accumulated indoors is discharged at night • Integration of air conditioning into HRV unit • Increased static pressure thanks to improved fan performance • Integrated control with VRV® system only • Connectable to current Daikin control systems:

[iPU]

VKM-GA Ventilation & DX coil Fresh air conditioning load Air flow rate Sound pressure level - 220V Sound pressure level - 240V Static pressure Temperature exchange efficiency Enthalpy exchange efficiency - cooling Enthalpy exchange efficiency - heating Dimensions

Weight Power supply

Cooling Heating UH - H - L UH - H - L UH - H - L UH - H - L UH - H - L UH - H - L UH - H - L Height Width Depth

kW kW m3/h dBA dBA Pa % % % mm mm mm kg V1

VKM50GA 4.71 5.58 500 - 500 - 440 38 - 36 - 33.5 39 -37 - 33.5 180 - 150 - 110 76 - 76 - 77.5 64 - 64 - 67 67 - 67 - 69 387 1,764 832 96

VKM80GA 7.46 8.79 750 - 750 - 640 40 - 37.5 - 34.5 41.5 - 39 - 37 170 - 120 - 80 78 - 78 - 79 66 - 66 - 68 71 - 71 - 73 387 1,764 1,214 109 1 ~, 220-240V, 50Hz

VKM100GA 9.12 10.69 950 - 950 - 820 40 - 38 - 35 41 - 39 - 36.5 150 - 100 - 70 74 - 74 - 76.5 62 - 62 - 66 65 - 65 - 69 387 1,764 1,214 114

166 2515_BOOK_Ventilation_2011.indb 166

21/03/2011 08:50


FXMQ-MF

Outdoor air processing unit

• 100% fresh air intake possible • Operation range: -5°C to 43°C • 225 Pa external static pressure allows extensive ductwork

FXMQ250MF

runs and flexible application: ideal for use in large areas

• Drain pump kit available as accessory

FXMQ-MFV1 Indoor Units Capacity Power input Dimensions Weight Air Flow Rate Power Supply Piping connections

Cooling Heating Cooling Heating (Height x Width x Depth) Cooling Heating

Medium Medium

Liquid (OD)/Gas/Drain

kw kw kw kw mm kg m³/min m³/min mm

FXMQ125MFV1 14.0 8.9 0.359 0.359 470x744x1100 86 18.0 18.0 9.5 / 15.9 / PS1B

FXMQ200MFV1 22.4 13.9 0.548 0.548

FXMQ250MFV1 28.00 17.40 0.638 0.638 470x1380x1100 123

28.0 28.0 220-240V/50Hz 9.5 / 19.1 / PS1B

35.0 35.0 9.5 / 22.2 / PS1B

167 2515_BOOK_Ventilation_2011.indb 167

21/03/2011 08:50


VRV®

Air handling applications

Air handling unit

EXV-kit

A R-410A inverter condensing units range for multi application with air handling units. • • • • •

Inverter controlled units Large capacity range (from 5 to 18HP) Cooling only and heat pump R-410A

EKEXMCB gas pipe

Control z: control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed)

liquid pipe F1,F2 communication

• Large range of expansion valve kits available • BRC1E51A is used to set the set point temperature (connected to the EKEXMCB).

Outdoor Unit RXYQ-P9 Capacity range Capacity Power Input Dimensions Weight Sound Level

Cooling Cooling (Height x Width x Depth)

Sound Power Cooling Sound Cooling Air Flow Rate (Nominal) at 230V) Cooling Operation Range Cooling Min~Max Refrigerant Power Supply Max n° of indoor units to be connected Piping connections Liquid (OD)/Gas

HP kW kW mm kg dBA dBA m3/min °CDB

mm

5 5 14.0 3.52 1,680x635x765 157 72 54 95

8 8 22.4 5.56

10 10 28.0 7.42 1,680x930x765

57 171

58 185

8 9.5 / 15.9

13 9.5 / 19.1

16 9.5 / 22.2

185

12 12 33.5 9.62

14 14 40.0 12.4

238

16 16 45.0 14.2 1,680x1,240x765 315

78

323 83 63 239

80 60 196 -5.0~43.0 R-410A 3N~/400V/50Hz 19 12.7 / 22.2

233

23

18 18 49.0 16.2

26 12.7 / 28.6

29 15.9 / 28.6

Combination Table Control box

3ph

Expansion valve kit

Outdoor units

control z

class 50

class 63

class 80

class 100

class 125

class 140

class 200

class 250

RXYQ5P9 RXYQ8P9 RXYQ10P9 RXYQ12P9 RXYQ14P9 RXYQ16P9 RXYQ18P9

EKEXMCB X X X X X X X

EKEXV50 X X X X X X X

EKEXV63 X X X X X X X

EKEXV80 X X X X X X X

EKEXV100 X X X X X X X

EKEXV125 X X X X X X X

EKEXV140 X X X X X X X

EKEXV200 X X X X X X X

EKEXV250 X X X X X X X

168 VRV.indd 168

30/03/2011 19:37


ERQ

Condensing units for air handling applications (pair)

A range of R-410A inverter condensing units for pair application with air handling units. Inverter controlled heat pump units with R-410A refrigerant. • • • • •

Large capacity range (from 100 to 250 class) Wide range of expansion valve kits available (from 63 to 250 class) Ventilation and air conditioning in one solution EKEXV-kit & control boxes are designed for outdoor installation and can be wall mounted Outdoor unit operation range: -5°CDB ~ 43°CDB

• F lexible control possibilities: Control x: control of air temperature (discharge temperature, suction temperature, room temperature) via external device (DDC controller) Control y: control of evaporating temperature via Daikin control (no DDC controller needed) Control z: control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed).

Air handling unit Liquid pipe

Liquid pipe

Gas pipe

Gas pipe

(Field Supply)

Expansion valve kit: EKEXV

F1,F2 communication

Control box: EKEQDCB: control z EKEQFCB: control x,y

DDC control (control x)

169 2515_BOOK_Ventilation_2011.indb 169

21/03/2011 08:50


HEAT PUMP Outdoor units Capacity Power input

Cooling Heating Cooling Heating

EER COP Casing Dimensions Weight Sound power level Sound pressure level Operation range

Nominal Nominal Nominal Nominal

kW kW kW kW

ERQ100AV1 11.2 12.5 2.81 2.74

ERQ125AV1 14.0 16.0 3.51 3.86

ERQ140AV1 15.5 18.0 4.53 4.57 3.42 3.94

3.99 4.56 Colour Material HxWxD Cooling Cooling Heating Cooling Heating

Refrigerant type Piping connections

Piping length Power supply

Nominal Nominal Nominal Min-Max Min-Max

mm kg dBA dBA dBA °CDB °CWB

Liquid Gas Drain Max total length

mm mm mm m

Nominal Nominal Nominal Nominal

kW kW kW kW

4.15 Daikin White Painted galvanized steel plate 1,345 x 900 x 320 120 67 51 53 -5 ~ 46 -20 ~ 15.5 R-410A ø9.52

66 50 52

69 53 55

ø15.9

ø19.1 3 x ø26 55 1 ~, 220-240V, 50Hz

HEAT PUMP Outdoor units Capacity Power input

Cooling Heating Cooling Heating

EER COP Casing Dimensions Weight Sound power level Sound pressure level Operation range

Colour Material HxWxD Cooling Cooling Cooling Heating

Refrigerant type Piping connections Piping length Power supply

Nominal Nominal Min-Max Min-Max

mm kg dBA dBA °CDB °CWB

Liquid mm Gas mm Max total length m

ERQ125AW1 14.0 16.0 3.52 4.00 3.98 4.00

ERQ200AW1 22.4 25.0 5.22 5.56 4.29 4.50 Daikin White Painted galvanized steel plate

1,680 x 635 x 765 159 72 54

ø15.9

ERQ250AW1 28.0 31.5 7.42 7.70 3.77 4.09

1,680 x 930 x 765 187

240 78

57 -5 ~ 43 -20 ~ 15 R-410A ø9.52 ø19.1 55 3N~, 400V, 50Hz

58

ø22.2

170 2515_BOOK_Ventilation_2011.indb 170

21/03/2011 08:50


VAP(W)-L

Air handling units

Air handling units The Daikin range has 5 air flow volumes from 1750 m3/hr (0.48 m/3s) to 9000 m/3hr (2.54 m/3s) all capable of 250 pa external static. They can be broken down into 3 distinct groups all of which are available in both Internally mounted plant room - VAP and externally mounted weatherproofed types - VAW. The range VAP/WLA-D is a straight forward supply only unit • Type A with heating by LTHW, Type B with heating by Electric, Type C with heating by LTHW & DX cooling, Type D with heating by Electric & DX cooling,

The range VAP/WLE-H is a Supply & Extract with a Heat cube plate heat exchanger which recovers sensible heat thus reducing energy • Type E Heat Cube with heating by LTHW, Type F Heat Cube with heating by Electric, Type G Heat Cube with heating by LTHW & DX cooling, Type H Heat Cube with heating by Electric & DX cooling,

The range VAP/WLI-L is a Supply & Extract with a Thermal Wheel heat exchanger which recovers sensible heat thus reducing energy • Type I Thermal Wheel with heating by LTHW, Type J Thermal Wheel with heating by Electric, Type K Thermal Wheel with heating by LTHW & DX cooling, Type L Thermal Wheel with heating by Electric & DX cooling.

Capacity conditions The heating conditions are based on Airside - 5°C db on and 20°C db off, LTHW on 82°C & off @ 71°C The cooling conditions are based on Airside on coil 32°C db / 22°C wb, off @ 22°C db & 18°C wb using R410A @ 6°C Evaporating Notes Units come as standard with left hand connections (in direction of airflow) but right hand are available at no extra charge. Filtration - All models with heating coils have G4 (panel) Class filtration all units with heating & cooling coils have G4 (panel) + F6 (bag) Class filtration. The larger internal units are delivered in a number of sections which will assist in getting these units into plant room areas the number of sections are shown on the following pages (indicated as shipped in pcs) further details are shown on the General Arrangement drawings. These units will need bolting together on site (by others). The noise levels shown are Sound power levels (dbA) at source you should note that the models with supply and extract fans (models E to L) may have different noise levels which is why they are shown separately. For further details please refer to the Technical Manual, Data Sheets or General Arrangement drawings.

Type

Fan

Damper

Filter – G4 Panel

A

3

3

3

B

3

3

3

Filter - F6 Bag Rigid

3

3

3

3

3

3

3

3

E

3

3

3

F

3

3

3

3

3

3

3

H

3

3

3

3

I

3

3

3

3

3

3

3

3

L

3

3

3

3

Recoup

Wheel

3 3

3

3

G

3

Cooling DX R410A

3

C

J

Electric

3

D

K

Heating LTHW

3 3

3 3

3 3

3

3

3

3

3 3

3 3

3

3 3

3

3

3

171 2515_BOOK_Ventilation_2011.indb 171

21/03/2011 08:50


VAP-L

Specification tables Types A, B, C

Internally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Heating Grade Power Supply

Fan Run Current Start Current

Complete with LPHW heating coil Type A m3/hr pa mm mm mm kg Pcs dB kW V Hz ph kW A A

VAPLA1750AW 1750

VAPLA3000AW 3000

1400 790 654 126 1 79.9 14.54

1630 890 754 170 1 83.1 23.94

0.75 1.79 12.26

1.1 2.5 17.5

VAPLB1750AW 1750

VAPLB3000AW 3000

2030 790 654 133 1 79.8 15

2030 890 754 178 1 82.9 24

0.75 2.05 11.1

1.1 2.5 17.5

Internally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Heating Grade Power Supply

Fan Run Current Start Current

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Cooling Heating Grade Power Supply

Fan Run Current Start Current Condensing Unit Expansion Valve Kit Control box option

VAPLA7000AW 7000

VAPLA9000AW 9000

1830 1190 1054 280 1 81.1 60

1630 1190 1354 304 1 84.9 76.97

2.2 4.59 35.8

3 6.19 46.42

Complete with Electric heating coil Type B m3/hr pa mm mm mm kg Pcs dB kW V Hz ph kW A A

Internally Mounted Air Handling Unit Air flow External Static Dimensions

VAPLA4000AW 4000 250 1480 890 1054 181 1 81.1 34.24 G4 400 50 3 1.1 2.5 17.5

VAPLB4000AW 4000 250 2080 890 1054 191 1 80.9 36 G4 400 50 3 1.1 2.5 17.5

VAPLB7000AW 7000

VAPLB9000AW 9000

2380 1190 1054 290 1 81.1 60

2200 1190 1354 319 1 84.8 82.5

2.2 4.59 35.8

3 6.19 46.43

Complete with LPHW heating coil & R410a DX Cooling coil Type C m3/hr pa mm mm mm kg Pcs dB kW kW V Hz ph kW A A

VAPLC1750AW 1750 2330 790 754 205 1 82.2 7.68 14.54

0.55 1.27 8.84 ERQ100A EKEXV63 EKEQFCB

VAPLC3000AW 3000

VAPLC4000AW VAPLC7000AW 4000 7000 250 2510 2560 2670 890 990 1190 854 954 1254 248 252 383 2 2 2 81.6 82.5 85.9 12.57 18.10 31.80 23.94 34.24 60 F6 + G4 400 50 3 1.1 1.5 2.2 2.31 3.05 4.28 17.09 24.1 35.52 Recommendation for connection to Daikin condensing units ERQ125A ERQ200A 2 x ERQ140A EKEXV125 EKEXV200 2 x EKEXV140 EKEQFCB EKEQFCB 2 x EKEQFCB

VAPLC9000AW 9000 2810 1240 1354 443 2 86 40.42 76.97

3 6.2 46.5 2 x ERQ200A 2 x EKEXV200 2 x EKEQFCB

172 2515_BOOK_Ventilation_2011.indb 172

21/03/2011 08:50


VAP-L

Specification tables Types D, E, F

Internally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Cooling Heating Grade Power Supply

Fan Run Current Start Current

Complete with Electric heating coil & R410a DX Cooling coil Type D m3/hr pa mm mm mm kg Pcs dB kW kW V Hz ph kW A A

Condensing Unit Expansion Valve Kit Control box option

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

0.55 1.27 8.84

Length Height Width Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

VAPLD3000AW 3000

VAPLD4000AW VAPLD7000AW 4000 7000 250 2600 2630 2820 890 990 1190 854 954 1254 259 297 395 2 2 2 81.5 82.3 85.9 12.57 18.10 31.80 24 36 60 F6 + G4 400 50 3 1.1 1.5 2.2 2.31 3.05 4.28 17.01 24.1 35.52 Recommendation for connection to Daikin condensing units ERQ125A ERQ200A 2 x ERQ140A EKEXV125 EKEXV200 2 x EKEXV140 EKEQFCB EKEQFCB EKEQFCB

VAPLD9000AW 9000 2970 1240 1354 458 2 85.9 40.42 82.5

3 6.19 46.43 2 x ERQ200A 2 x EKEXV200 EKEQFCB

Heat Recovery (Plate Heat Exchanger) Complete with LPHW heating coil Type E m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

Internally Mounted Air Handling Unit Air flow External Static Dimensions

2440 790 754 214 1 82 7.68 15

ERQ100A EKEXV63 EKEQFCB

Internally Mounted Air Handling Unit Air flow External Static Dimensions

VAPLD1750AW 1750

VAPLE1750AW 1750

VAPLE3000AW 3000

2580 1480 654 538

2780 1680 754 548

82.3 82.1 14.54

85.2 85.1 23.94

1.1 2.31 17.09 1.1 2.31 17.09

1.5 3.19 22.6 1.1 2.5 17.5

VAPLE4000AW 4000 250 2630 1680 1054 616 2 83.5 83.4 34.24 G4 400 50 3 1.5 3.19 22.6 1.5 3.19 22.6

VAPLE7000AW 7000

VAPLE9000AW 9000

3280 2280 1054 810

3010 2280 1354 910

82.9 82.8 60

86.5 86.5 76.97

3 6.19 46.42 3 6.19 46.42

4 7.81 56.23 4 7.81 56.23

Heat Recovery (Plate Heat Exchanger) Complete with Electric heating coil Type F m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

VAPLF1750AW 1750

VAPLF3000AW 3000

2580 1480 654 538

2780 1680 754 548

82.1 82.1 15

85 85.1 24

1.1 2.31 17.09 1.1 2.31 17.09

1.5 3.19 22.65 1.1 2.5 17.5

VAPLF4000AW 4000 250 2730 1680 1054 627 2 83.3 83.4 36 G4 400 50 3 1.5 3.19 22.65 1.5 3.19 22.65

VAPLF7000AW 7000

VAPLF9000AW 9000

3280 2280 1054 822

3060 2280 1354 923

82.6 82.8 60

86.4 86.5 82.5

3 6.19 46.43 3 6.19 46.43

4 7.81 56.23 4 7.81 56.23

173 2515_BOOK_Ventilation_2011.indb 173

21/03/2011 08:50


VAP-L

Specification tables Types G, H, I

Internally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

Heat Recovery Plate Heat Exchanger LPHW heating & R410a DX Cooling Type G m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

Condensing Unit Expansion Valve Kit Control box option

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

Capacity Filter Electrical Details

3650 1680 854 603 2 83.6 85.1 6.47 23.94

82.6 82.1 4.02 14.54

Length Height Width Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

VAPLG7000AW 7000

VAPLG9000AW 9000

4480 2280 1254 990

4290 2380 1354 1080 3

87.4 87.2 83.7 82.7 10.02 17.83 34.24 60 F6 + G4 400 50 3 1.1 2.2 3 2.31 4.28 5.6 17.09 35.52 40.88 1.1 1.5 3 2.5 3.19 6.19 17.5 22.65 46.53 Recommendation for connection to Daikin condensing units ERQ100A ERQ100A ERQ200A EKEXV63 EKEXV100 EKEXV200 EKEQFCB EKEQFCB EKEQFCB

0.75 1.79 12.28 1.1 2.5 17.5

VAPLH1750AW 1750

VAPLH3000AW 3000

3580 1480 754 510

3830 1680 854 620 2 84.8 82.5 6.47 24

82 84 4.02 15

87.2 86.5 21.82 76.97

4 7.81 56.23 4 7.81 56.23 ERQ200A EKEXV200 EKEQFCB

VAPLH4000AW 4000 250 3480 1680 1154 670

VAPLH7000AW 7000

VAPLH9000AW 9000

4480 2280 1254 990

4340 2380 1354 1080 3

87.3 87.2 83.7 84.2 10.02 17.83 36 60 F6 + G4 400 50 3 1.1 2.2 3 2.31 4.28 6.19 17.09 26.96 46.42 1.1 1.5 3 2.5 3.19 6.19 17.5 22.6 46.42 Recommendation for connection to Daikin condensing units ERQ100A ERQ100A ERQ200A EKEXV63 EKEXV100 EKEXV200 EKEQFCB EKEQFCB EKEQFCB

0.75 1.79 12.28 1.1 2.5 17.5 ERQ100A EKEXV63 EKEQFCB

Internally Mounted Air Handling Unit

Weight Shipped in Sound Power Level

3330 1480 754 503

VAPLG4000AW 4000 250 3230 1680 1154 659

Heat Recovery Plate Heat Exchanger Electric heating & R410a DX Cooling Type H

Condensing Unit Expansion Valve Kit Control box option

Air flow External Static Dimensions

VAPLG3000AW 3000

ERQ100A EKEXV63 EKEQFCB

Internally Mounted Air Handling Unit Air flow External Static Dimensions

VAPLG1750AW 1750

88.4 83.1 21.82 82.5

4 7.11 50.48 3 6.19 46.53 ERQ200A EKEXV200 EKEQFCB

Heat Recovery (Thermal Wheel) Complete with LPHW heating coil Type I m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

VAPLI4000AW 4000 2630 1680 1154 649 3 83.6 83.2 34.24

1.5 3.19 22.6 1.5 3.19 22.6

VAPLI7000AW 7000 250 2840 2080 1354 826 3 91.1 91.2 60 G4 400 50 3 3 6.19 46.43 3 6.19 46.43

VAPLI9000AW 9000 2960 2280 1454 997 3 86.4 86.2 76.97

4 7.81 56.23 4 7.81 56.23

174 2515_BOOK_Ventilation_2011.indb 174

21/03/2011 08:50


VAP-L

Specification tables Types J, K, L

Internally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

Heat Recovery (Thermal Wheel) Complete with Electric heating coil Type J m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

Internally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Dry Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

Internally Mounted Air Handling Unit

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current Condensing Unit Expansion Valve Kit Control box option

2630 1680 1154 649 83.4 83.2 36

1.5 3.19 22.65 1.5 3.19 22.65

VAPLK4000AW 4000

VAPLK7000AW 7000 250 3540 2080 1354 948

3330 1680 1154 649 2 87.3 83.2 5.15 34.24

86.9 82 9.02 60 F6 + G4 400 50 3 3 5.6 40.88 3 6.19 46.43 Recommendation for connection to Daikin condensing units ERQ100A EKEXV80 EKEQFCB

2.2 4.28 35.52 1.5 3.19 22.6 ERQ100A EKEXV63 EKEQFCB

Length Height Width Dry

VAPLJ7000AW 7000 250 2840 2080 1354 872 2 82.1 82 60 G4 400 50 3 3 6.19 46.43 3 6.19 46.43

VAPLJ9000AW 9000 2960 2280 1454 997 86.3 86.2 82.5

4 7.81 56.23 4 7.81 56.23

Heat Recovery (Thermal Wheel) LPHW heating & R410a DX Cooling coil Type K

Condensing Unit Expansion Valve Kit Control box option

Air flow External Static Dimensions

VAPLJ4000AW 4000

VAPLK9000AW 9000 3610 2280 1454 1065 3 91.2 86.2 11.6 76.97

4 7.11 50.48 4 7.81 56.23 ERQ125A EKEXV100 EKEQFCB

Heat Recovery (Thermal Wheel) Electric heating & R410a DX Cooling coil Type L m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

VAPLL4000AW 4000

VAPLL7000AW 7000 250 3680 2080 1354 971

3610 1680 1154 649 2 87.3 83.2 5.15 36

2.2 4.28 35.52 1.5 3.19 22.65 ERQ100A EKEXV63 EKEQFCB

86.9 82 9.02 60 F6 + G4 400 50 3 3 5.6 40.88 3 6.19 46.43 Recommendation for connection to Daikin condensing units ERQ100A EKEXV80 EKEQFCB

VAPLL9000AW 9000 3730 2280 1454 1065 3 91.1 86.2 11.6 82.5

4 7.11 50.48 4 7.81 56.23 ERQ125A EKEXV100 EKEQFCB

175 2515_BOOK_Ventilation_2011.indb 175

21/03/2011 08:50


VAW-L

Specification tables Types A, B, C

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Heating Grade Power Supply

Fan Run Current Start Current

Complete with LPHW heating coil Type A m3/hr pa mm mm mm kg Pcs dB kW V Hz ph kW A A

VAWLA1750AW 1750

VAWLA3000AW 3000

1600 790 654 176 1 79.9 14.54

1670 890 754 176 1 83.4 23.94

0.75 2.06 11.1

1.1 2.5 17.5

VAWLB1750AW 1750

VAWLB3000AW 3000

2070 790 654 137 1 80.2 15

2130 890 754 182 1 83.2 24

0.75 2.06 11.1

1.1 2.5 17.5

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Heating Grade Power Supply

Fan Run Current Start Current

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Cooling Heating Grade Power Supply

Fan Run Current Start Current Condensing Unit Expansion Valve Kit Control box option

VAWLA7000AW 7000

VAWLA9000AW 9000

1900 1190 1054 289 1 81.3 60

1700 1190 1354 315 1 85 76.97

2.2 4.59 35.8

3 6.19 46.42

Complete with Electric heating coil Type B m3/hr pa mm mm mm kg Pcs dB kW V Hz ph kW A A

Externally Mounted Air Handling Unit Air flow External Static Dimensions

VAWLA4000AW 4000 250 1750 890 1054 222 1 81.3 34.24 G4 400 50 3 1.5 3.19 22.6

VAWLB4000AW 4000 250 2090 890 1054 203 1 81.1 36 G4 400 50 3 1.1 2.5 17.5

VAWLB7000AW 7000

VAWLB9000AW 9000

2380 1190 1054 289 1 81.1 60

2310 1190 1354 330 1 84.9 82.5

2.2 4.59 35.8

3 6.19 46.42

Complete with LPHW heating coil & R410a DX Cooling coil Type C m3/hr pa mm mm mm kg Pcs dB kW kW V Hz ph kW A A

VAWLC1750AW 1750 2350 790 754 213 1 82.3 7.68 14.54

0.55 1.27 8.84 ERQ100A EKEXV63 EKEQFCB

VAWLC3000AW 3000

VAWLC4000AW VAWLC7000AW 4000 7000 250 2400 2400 2550 890 990 1190 854 954 1254 252 290 385 1 1 1 81.8 82.6 86 12.57 18.10 31.80 23.94 34.24 60 F6 + G4 400 50 3 1.1 1.5 2.2 2.31 3.05 4.28 17.09 24.1 35.52 Recommendation for connection to Daikin condensing units ERQ125A ERQ200A 2 x ERQ140A EKEXV125 EKEXV200 2 x EKEXV140 EKEQFCB EKEQFCB 2 x EKEQFCB

VAWLC9000AW 9000 2700 1240 1354 447 1 86.1 40.42 76.97

3 6.19 46.43 2 x ERQ200A 2 x EKEXV200 2 x EKEQFCB

176 2515_BOOK_Ventilation_2011.indb 176

21/03/2011 08:50


VAW-L

Specification tables Types D, E, F

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Cooling Heating Grade Power Supply

Fan Run Current Start Current

Complete with Electric heating coil & R410a DX Cooling coil Type D m3/hr pa mm mm mm kg Pcs dB kW kW V Hz ph kW A A

Condensing Unit Expansion Valve Kit Control box option

VAWLD1750AW 1750 2560 790 754 219 1 82.2 7.68 15

0.55 1.27 8.84 ERQ100A EKEXV63 EKEQFCB

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

VAWLD4000AW VAWLD7000AW 4000 7000 250 2630 2680 2850 890 990 1190 854 954 1254 259 298 385 1 1 1 81.7 82.5 86 12.57 18.10 31.80 24 36 60 F6 + G4 400 50 3 1.1 1.5 2.2 2.31 3.05 4.59 17.09 24.1 35.8 Recommendation for connection to Daikin condensing units ERQ125A ERQ200A 2 x ERQ140A EKEXV125 EKEXV200 2 x EKEXV140 EKEQFCB EKEQFCB EKEQFCB

VAWLD9000AW 9000 2980 1240 1354 447 1 86 40.42 82.5

3 6.19 46.43 2 x ERQ200A 2 x EKEXV200 EKEQFCB

Heat Recovery (Plate Heat Exchanger) with LPHW heating coil Type E m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

VAWLE1750AW 1750

VAWLE3000AW 3000

2550 1480 654 380 1 82.7 82.4 14.54

2900 1680 754 555 1 85.5 85.4 23.94

1.1 2.31 17.09 1.1 2.31 17.09

1.5 3.19 22.33 1.5 3.19 22.65

Externally Mounted Air Handling Unit Air flow External Static Dimensions

VAWLD3000AW 3000

VAWLE4000AW 4000 250 2750 1680 1054 655 1 83.7 83.6 34.24 G4 400 50 3 2.2 4.59 35.6 1.5 3.19 22.6

VAWLE7000AW 7000

VAWLE9000AW 9000

3480 2280 1054 830 1 83.2 83 60

3130 2280 1354 940 1 86.7 86.7 76.97

3 6.19 46.42 3 6.19 46.42

4 7.81 56.23 4 7.81 56.23

Heat Recovery (Plate Heat Exchanger) with Electric heating coil Type F m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

VAWLF1750AW 1750

VAWLF3000AW 3000

2600 1480 654 382 1 82.5 82.4 15

2900 1680 754 570 1 85.3 85.4 24

1.1 2.31 17.09 1.1 2.31 17.09

1.5 3.19 22.65 1.5 3.19 22.65

VAWLF4000AW 4000 250 2850 1680 1054 645 1 83.5 90.1 36 G4 400 50 3 1.5 3.19 22.65 1.5 3.19 22.65

VAWLF7000AW 7000

VAWLF9000AW 9000

3400 2280 1054 850 1 82.9 83 60

3180 2280 1354 960 1 86.6 86.7 82.5

3 6.19 46.43 3 6.19 46.43

4 7.81 56.23 4 7.81 56.23

177 2515_BOOK_Ventilation_2011.indb 177

21/03/2011 08:50


VAW-L

Specification tables Types G, H, I

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

Heat Recovery Plate Heat Exchange LPHW heating & R410a DX Cooling Type G m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

Condensing Unit Expansion Valve Kit Control box option

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

Capacity Filter Electrical Details

3350 1480 754 522 1 84.2 82.5 4.02 14.54

0.75 1.79 12.28 1.1 2.5 17.5

VAWLH1750AW 1750

VAWLH3000AW 3000

VAWLH4000AW VAWLH7000AW 4000 7000 250 3950 3600 4450 1680 1680 2280 854 1154 1254 640 695 1030 1 1 1 85 87.4 87.3 82.8 83.8 84.2 6.47 10.02 17.83 24 36 60 F6 + G4 400 50 3 1.5 2.2 3 3.05 4.28 6.19 24.01 26.96 46.42 1.1 1.5 3 2.5 3.19 6.19 17.5 22.6 46.42 Recommendation for connection to Daikin condensing units ERQ100A ERQ100A ERQ200A EKEXV63 EKEXV100 EKEXV200 EKEQFCB EKEQFCB EKEQFCB

3600 1480 754 525 1 84.2 82.2 4.02 15

0.75 1.79 12.28 1.1 2.5 17.5 ERQ100A EKEXV63 EKEQFCB

Externally Mounted Air Handling Unit

Weight Shipped in Sound Power Level

VAWLG4000AW VAWLG7000AW 4000 7000 250 3750 3350 4350 1680 1680 2280 854 1154 1254 630 683 1005 1 1 1 83.8 87.5 87.3 85.3 83.8 82.9 6.47 10.02 17.83 23.94 34.24 60 F6 + G4 400 50 3 1.1 2.2 3 2.31 4.28 5.6 17.09 35.52 40.88 1.5 1.5 3 3.19 3.19 6.19 22.65 22.65 46.53 Recommendation for connection to Daikin condensing units ERQ100A ERQ100A ERQ200A EKEXV63 EKEXV100 EKEXV200 EKEQFCB EKEQFCB EKEQFCB

Length Height Width Delivered Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

VAWLG9000AW 9000 4350 2380 1354 1105 1 87.3 86.7 21.82 76.97

4 7.81 56.23 4 7.81 56.23 ERQ200A EKEXV200 EKEQFCB

Heat Recovery Plate Heat Exchanger Electric heating & R410a DX Cooling Type H

Condensing Unit Expansion Valve Kit Control box option

Air flow External Static Dimensions

VAWLG3000AW 3000

ERQ100A EKEXV63 EKEQFCB

Externally Mounted Air Handling Unit Air flow External Static Dimensions

VAWLG1750AW 1750

VAWLH9000AW 9000 4500 2380 1354 1220 1 85.6 83.3 21.82 82.5

4 7.81 56.23 4 7.81 56.23 ERQ200A EKEXV200 EKEQFCB

Heat Recovery (Thermal Wheel) Complete with LPHW heating coil Type I m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

VAWLI4000AW 4000 2650 1680 1154 705 1 83.8 83.3 34.24

2.2 4.59 35.8 1.5 3.19 22.6

VAWLI7000AW 7000 250 2860 2080 1354 930 1 82.4 82.1 60 G4 400 50 3 3 6.19 46.43 3 6.19 46.43

VAWLI9000AW 9000 2980 2280 1454 1060 1 86.5 86.3 76.97

4 7.81 56.23 4 7.81 56.23

178 2515_BOOK_Ventilation_2011.indb 178

21/03/2011 08:50


VAW-L

Specification tables Types J, K, L

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Return Fan Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

Heat Recovery (Thermal Wheel) Complete with Electric heating coil Type J m3/hr pa mm mm mm kg Pcs dB dB kW V Hz ph kW A A kW A A

Externally Mounted Air Handling Unit Air flow External Static Dimensions

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Length Height Width Delivered Dry Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current

m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

Externally Mounted Air Handling Unit

Weight Shipped in Sound Power Level Capacity Filter Electrical Details

Supply Fan Return Fan Cooling Heating Grade Power Supply

Supply Fan Run Current Start Current Return Fan Run Current Start Current Condensing Unit Expansion Valve Kit Control box option

2650 1680 1154 664 1 83.6 83.3 36

1.5 3.19 22.6 1.5 3.19 22.6

VAWLK4000AW 4000 3350 1680 1154 758 1 87.5 83.3 5.15 34.24

2.2 4.28 35.52 1.5 3.19 22.6 ERQ100A EKEXV63 EKEQFCB

Length Height Width Delivered Dry

VAWLJ7000AW 7000 250 2860 2080 1354 940 1 82.2 82.1 60 G4 400 50 3 3 6.19 46.43 3 6.19 46.43

VAWLJ9000AW 9000 2980 2280 1454 1070 1 86.4 86.3 82.5

4 7.81 56.23 4 7.81 56.23

Heat Recovery (Thermal Wheel) LPHW heating & R410a DX Cooling coil Type K

Condensing Unit Expansion Valve Kit Control box option

Air flow External Static Dimensions

VAWLJ4000AW 4000

VAWLK7000AW 7000 250 2560 2080 1354 992 1 87 82.1 9.02 60 F6 + G4 400 50 3 3 5.6 40.88 3 6.19 46.43 Recommendation for connection to Daikin condensing units ERQ100A EKEXV80 EKEQFCB

VAWLK9000AW 9000 3630 2280 1454 1130 1 91.2 86.3 11.6 76.97

4 7.11 50.48 4 7.81 56.23 ERQ125A EKEXV100 EKEQFCB

Heat Recovery (Thermal Wheel) Electric heating & R410a DX Cooling coil Type L m3/hr pa mm mm mm kg Pcs dB dB kW kW V Hz ph kW A A kW A A

VAWLL4000AW 4000 3630 1680 1154 762 1 87.4 83.3 5.15 36

2.2 4.28 35.52 1.5 3.19 22.65 ERQ100A EKEXV63 EKEQFCB

VAWLL7000AW 7000 250 3700 2080 1354 971 1 86.9 82.1 9.02 60 F6 + G4 400 50 3 3 5.6 40.88 3 6.19 46.43 Recommendation for connection to Daikin condensing units ERQ100A EKEXV80 EKEQFCB

VAWLL9000AW 9000 3750 2280 1454 1133 1 91.2 86.3 11.6 82.5

4 7.11 50.48 4 7.81 56.23 ERQ125A EKEXV100 EKEQFCB

179 2515_BOOK_Ventilation_2011.indb 179

21/03/2011 08:50


180 2515_BOOK_Ventilation_2011.indb 180

21/03/2011 08:50


2515_BOOK_ControlSystems_2011.indb 181

21/03/2011 07:34


Control systems In order to realise maximum efficiency, commercial air conditioning systems must be subject to precise, 24 hour control.

Daikin manufactures and markets a complete suite of advanced computerised central control and monitoring systems designed to simplify air conditioning management and reduce energy usage running costs. Daikin computerised control systems not only provide the highly sophisticated regulation and day to day monitoring necessary for modern, hi tech air

conditioning installations – they also provide owners, landlords and tenants of commercial buildings with valuable performance data on consumption as well as a wide range of operating parameters. Dedicated Daikin central control can be applied to both VRVŽ and mixed VRVŽ/Sky Air and Split installations with up to 1,024 indoor units and can also be integrated with building management systems.

1. Individual control systems

Wired remote control Simplified remote control Infrared remote control

183 183 183

2. Network solutions

Intelligent Touch Controller Intelligent Manager DMS-IF BACnet Gateway DNSS EcoSave

184 186 187 187 189

For a copy of our latest Price List please call 0845 6419000

182 Control systems.indd 182

30/03/2011 19:38


Individual control systems

BRC1E51A

BRC2C51

BRC4*/BRC7*

BRC1E51A

BRC2C51

BRC4*/BRC7*

User-friendly remote control with contemporary design.

Simple, compact and easy to operate unit, suitable for use in hotel bedrooms.

Operation buttons: ON/OFF, operating mode selection, fan speed control, temperature setting, menu management.

Operation buttons: ON/OFF, operating mode selection, fan speed control, temperature setting.

Easy Setup: All main functions directly accessible, improved graphical user interface for advanced menu settings.

Display: Cool/heat changeover control, Heat Recovery Ventilation (HRV) in operation, set temperature, operating mode, centralised control indication, fan speed, defrost/hot start, malfunction adjustment, operating mode selection, fan speed control, filter sign reset, inspection test/operation.

Operation buttons: ON/OFF, timer mode start/stop, timer mode on/off, programme time, temperature setting, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), operating mode, fan speed control, filter sign reset, inspection / test indication.

Wired remote control

Display: Real time clock with auto update to daylight saving time, schedule timer with holiday setting, weekly timer and home leave operation, built-in backup power when a power failure occurs, all settings remain stored up to 48 hours.

Multilingual display Guide on display Backlight Contrast adjustment Keylock Built-in, backup power Schedule and setback capabilities User restriction options Louver position adjustment Reports system malfunctions Space temperature sensor Simultaneous operation with Daikin multi-zone controllers Simultaneous operation with BACnet® and LonWorks® Group control capacity Communications 1

Simplified remote control

Infrared remote control

Display: Operating mode, battery change, set temperature, air flow direction (FXHQ, FXFQ, FXCQ and FXAQ models only), programmed time, inspection/test operation, fan speed.

Wired remote control BRC1E51A

'Simplified' (built-in) wired remote BRC2C51 / BRC3A61

Wireless remote control BRC4* / BRC7*

             Up to 16 indoor units 2-wire / P1-P2

   Up to 16 indoor units 2-wire / P1-P2

 1   Up to 16 indoor units Infrared

Audible tones from the indoor unit indicate existing malfunction details

183 2515_BOOK_ControlSystems_2011.indb 183

21/03/2011 07:34


Network solutions Allows detailed & easy monitoring and operation of VRV® systems (max. 2 X 64 groups/indoor units). third party controller (domotics, BMS, etc.)

Public line Airconditioning Network Service System

Onboard modem

Fire alarm

Ethernet Forced OFF contact input

PCMCIA flash memory

DIII-NET

• CSV output of PPD (option) result

Indoor units

HRV

Pi-port Onboard Ethernet port

DIO unit Links to the wattmeter when using the PPD (option) function

Controls drain pump lighting etc.

Malfunction

Monitoring of room enter/ exit sign DI unit

Remote monitoring/control via internet, e-mail PPD data is available on the internet RS-232C

DIII-NET Allows monitoring/control of up to 64 units (groups) of A/Cs and equipment

DIII-NET PLUS adapter Indoor units

Languages • English • German • Portuguese

• French • Italian

• Spanish • Dutch

System layout • Up to 2 x 64 indoor units can be controlled • Onboard Ethernet port (web browser + e-mail) • Digital i/o contacts (option) • Touch panel (full colour LCD via icon display)

Management • Web application & internet compatibility - Monitoring & control according to user - Remote monitoring & control of more than one building - Remote monitoring & control of more than one building via internet • Power Proportional Distribution: PPD (option) • PPD data is available on the internet • Easy management of electricity consumption • Enhanced history function

HRV

Control

Monitoring

• Individual control (set point, start/stop, fan speed) (max. 2 x 64 groups/indoor units) • Enhanced scheduling function (8 schedules, 17 patterns) • Flexible grouping in zones • Yearly schedule • Fire emergency stop control • Interlocking control • Increased HRV monitoring and control function • Automatic cooling / heating change-over • Heating optimization • Temperature limit • Password security: 3 levels (general, administration & service) • Quick selection and full control • Simple navigation • Set back schedule new

• • • •

Visualisation via Graphical User Interface (GUI) Icon colour display change function Indoor units operation mode Error messages via e-mail & mobile phone (option) • Indication filter replacement • Multi PC

Cost performance • Free cooling function new • Labour saving • Easy installation • Compact design: limited installation space • Overall energy saving

Open interface • Communication to any third party controller (domotics, BMS, etc.) is possible via open interface

Connectable to: • VRV® • HRV

• Sky Air (via interface adapter) • Split (via interface adapter)

184 2515_BOOK_ControlSystems_2011.indb 184

21/03/2011 07:34


Network solutions Free Cooling function The combined application of the VRV system with VAM Heat Recovery Ventilation units can be greatly enhanced with the use of the Intelligent Touch Controller with it’s optional software which can support free cooling interlock with the VAM units providing cooling whilst restricting the VRV Indoor Units whenever the external temperature is within free cooling limits.

Advantages • Reduces the energy consumption and uses energy in a more efficient way, by directly introduction of fresh air into rooms. • Maintains indoor comfort through the introduction of low temperature outdoor air.

Free cooling function is possible when the outdoor temperature is less than the indoor room temperature

To perform this feature the Intelligent Touch Controller is required with the Free Cooling Software Update and also the use of the optional Outdoor Temperature Sensor Kit DAM101A51.

185 2515_BOOK_ControlSystems_2011.indb 185

21/03/2011 07:34


Network solutions [iPU]

The ideal solution for control and management of maximum 1,024 VRV® indoor units.

~

Intranet/Internet Web Access

Web Access Malfunction report by E-Mail

Air Conditioning Network Service System (Optional Maintenance Service)

(Via Internet) Ai unit

DAM602B51/52

DIII-NET DIII-NET Dio unit

~

Sub PC

DIII-NET

ETHERNET

DIII-NET

Fire alarm

Power supply facility · Elevator · Pump · Lighting,...

Electricity Measurement

VRV® System

Local monitoring & control

Daikin Central Air Conditioning System HRV

Languages

Management

Monitoring

• • • • • • •

• Web access (option) • Power Proportional Distribution (option) • Operational history management (start/stop, malfunction, operation hours) • Generation of reports (graphics & tables) (daily, weekly, monthly) • Peak load shedding • Advanced tenant management • Sliding temperature • Eco mode (option) • Pre cooling and heating function new

• Visualisation via a Graphical User Interface (GUI) featuring free layout • Operation mode of indoor units • Fault indication • Indication filter replacement • Setpoint indication • Operation time monitoring • Multi PC • On-line help

English French German Italian Spanish Dutch Portuguese

System layout • Up to 1,024 indoor units can be controlled (by 4 iPUs) • Ethernet TCPIP / 10 base / T communication • Integrated digital contacts on the Intelligent Processing Unit (iPU) · 20 general input ports · 2 digital outputs • Stand alone operation of the iPU for minimum 48 hours • Compatible with UPS shutdown software

Control • Individual control (setpoint, start/stop, fan speed) (max. 1,024 indoor units) • Group control (100 groups) • Schedule control (128 programs) • Fire emergency stop control (32 programs) • Interlocking control • Setpoint limitation • Automatic cooling/heating change-over • Power failure/release control • Temperature limit (automatic start) • Timer extension

Cost performance • Labour saving • Easy installation • Compact design: limited installation space • Overall energy saving

Connectable to: • VRV® • HRV • Sky Air (via interface adapter) • Split (via interface adapter)

186 2515_BOOK_ControlSystems_2011.indb 186

21/03/2011 07:34


Network solutions LON BMS ®

dms504b51

LonWorks® Networks Compatible Gateway

LonTalk

DIII- NET

ETHERNET (TCP/IP)

adapter

• Interface for Lon connection to LonWorks® networks • Communication via Lon® protocol (twisted pair wire) • 64 units connectable per DMS-IF • Unlimited sitesize • Quick and easy installation

Local Control VRV® Outdoor unit HRV

LonTalk adapter Remote Control LonPoint

LonPoint

BUILDING CONTROL NETWORK

DAIKIN A/C INFRASTRUCTURE

Security

BMS

Fire alarm System

DMS502A51

Integrated control system connecting VRV® system with BMS system Local Control

VRV® Outdoor unit BACNET / ETHERNET

• PPDdata is available on BMS system • Interface for BMS system • Communication via BACnet protocol (connection via Ethernet) • 256 units connectable per BACnet gateway • Unlimited sitesize • Easy and fast installation

DIII- NET

HRV

DAIKIN A/C INFRASTRUCTURE

Remote Control

Fire alarm

BUILDING CONTROL NETWORK

Pump

Security

Lighting

Power supply facility

Elevator

187 2515_BOOK_ControlSystems_2011.indb 187

21/03/2011 07:34


2515_BOOK_ControlSystems_2011.indb 188

21/03/2011 07:34


Daikin network service system Remote monitoring and diagnostics system for professionals The Daikin Network Service System is designed to optimise the running of your air conditioning equipment, increasing its operational efficiency, minimising possible down time and increasing customer comfort levels.

189 2515_BOOK_ControlSystems_2011.indb 189

21/03/2011 07:34


Unique innovation by Daikin What is the Daikin Network Service System (DNSS)? The DNSS is a remote monitoring system, which will allow you to continuously optimise the running of your Daikin equipment; control your energy consumption (so reduce your Carbon Footprint), extend the lifespan of your equipment and reduce operational costs.

YOUR INSTALLATION UNDER CONTINUOUS MONITORING • 24/7/365 remote monitoring • Predictive maintenance

Prevent product malfunctions The DNSS will analyse the data from your equipment every minute of the day and will alert us before the equipment actually breaks down. In this way, failures can be prevented and possible down time reduced to an absolute minimum.

Remote diagnostics

• Improved reliability • Improved comfort levels • Helps increase efficiency • Helps reduce maintenance costs • Extends product lifetime

The DNSS continuously checks the cleanliness of the system filters and heat exchanger. Furthermore, the DNSS manages a wide range of data (pressures, temperatures, running hours, etc.) in order to let your equipment run as efficiently and trouble free as possible. This will also prevent your equipment from using too much energy.

Extend product lifetime

extra value at low cost • A strategy of preventing breakdowns and limiting unnecessary maintenance visits

The DNSS is designed to make sure that your equipment is maintained and running as efficiently as possible. This optimisation will extend the lifespan of your equipment.

• Efficiently organising site interventions by diagnosing the nature and the extent of the problem before going to site

Malfunction messages

• Innovative technology that helps to optimise your equipment’s potential

In the unlikely event of a problem occurring, your regional Daikin office will contact you directly. Our engineers, who are dedicated to your installation, will inform you regarding the nature of the problem and will help you towards the next step of solving the problem.

• Ensures the most comfortable environment in your premises

190 2515_BOOK_ControlSystems_2011.indb 190

21/03/2011 07:34


2515_BOOK_AppliedSystems_2011.indb 191

25/03/2011 08:38


Applied systems Precise environmental control is vital in many industrial and commercial applications. Daikin offers an outstanding range of powerful air cooled, water cooled and condenserless chiller systems that will maintain ideal conditions in even the largest premises.

Daikin water chillers are of advanced design, compact and easy to install and maintain. They prove flexible and effective in multiple process cooling applications in for example, fish farms, wine cellars, maritime transport, agricultural, pharmaceutical or industrial processes. When combined with air handling units or Daikin fan coil units of course, they are ideal for air conditioning offices, hotels, restaurants and even domestic premises. Matched and flexible equipment/refrigerant combinations enable Daikin to offer a

1. Air cooled chiller

For a copy of our latest Price List please call 0845 6419000

new new new new new new new new new new

complete range of chillers, genuinely optimised for use with R-134a, R-407C and R-410A. All chiller components – evaporator, condenser, dryer, oil etc – have been specially selected for use with either R-407C, R-410A or R-134a refrigerants. The end result is a range of hi tech, high performance units, indicated by published EUROVENT data to be among the most energy efficient of their type on the market. Advanced technology, unsurpassed product reliability and quality, make Daikin chillers the first choice for professionals.

2. Condensing unit

EWAQ-ACV3 EWAQ-ACW1 EWYQ-ACV3 EWYQ-ACW1 EUWAC-FBZW1 EUWA*-KBZW1 EUWY*-KBZW1 EWAQ-DAYN EWYQ-DAYN EWAD-E-SS EWAD-E-SL EWAD-D-SS EWAD-D-SL EWAD-D-SR EWAD-D-SX EWAD-D-XS EWAD-D-XR EWAD-D-HS EWAD-BZSS/SL EWAD-BZXS/XL/XR EWYD-BZSS EWYD-BZSL EWAD-C-SS/SL EWAD-C-SR EWAD-C-XS/XL EWAD-C-XR EWAD-C-PS/PL EWAD-C-PR

195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222

ERAD-E-SS ERAD-E-SL

225 226

3. Water cooled chiller new

new new new new new

EWWP-KBW1N EWWD-MBYN EWWD-G-SS EWWD-G-XS EWWD-I-SS EWWD-I-XS EWWD-BJYNN EWWQ-AJYNN EWWQ-AJYNN/A EWWD-FZXS

229 231 232 233 234 235 236 237 238 239

4. Water cooled condenserless chiller new new

EWLP-KBW1N EWLD-MBYN EWLD-G-SS EWLD-I-SS

241 242 243 244

DICN (Daikin Integrated Chiller Network)

245

EHMC, EKBT (Hydraulic Module)

246

192 2515_BOOK_AppliedSystems_2011.indb 192

25/03/2011 08:38


Daikin chiller range Daikin’s 50 years of experience manufacturing chillers, has given us a comprehensive portfolio of cooling only, heat pumps and heat recovery models.

The range includes 5 kW to 2,200 kW, utilising both scroll and screw compressors designed and manufactured by Daikin. Now introducing a new range of inverter screw chillers with ESEERs over 5.

2000

1750

1500

1250

1000

Cooling Capacity (kW)

800

600

400

300

200

100

0

2000

1750

1500

1250

1000

50

Condenserless Range

Cooling Capacity (kW)

800

600

400

300

200

100

0

2000

1750

1500

1250

1000

800

50

Water Cooled Range

Cooling Capacity (kW)

600

400

300

200

100

50

0

Air Cooled Range

EWAQ080-260DY

R407c

EWYQ005-013AC

R410a

R410a

EWAQ005-013AC EWWQ400-C22A

EWLP012-065KB

EUWA5-24KB EUWY5-24KB

EWWP014-065KB

R134a

EWLD120-540MB EWLD340-C17I

EWWD170-600G

EWAD180-620D

EWAD650-C120

EWLD160-550G

EWWD120-540MB

EWAD330-490B

EWYD260-580BZ

R134a

R407c

R407c

EWYQ080-250DY

EWWD380-C11B EWWD340-C19I

COOLING ONLY

EWWD320-C10FZ

HEAT PUMP

193 2515_BOOK_AppliedSystems_2011.indb 193

25/03/2011 08:38


Air cooled chiller In the chilled water market, chillers of the air cooled type are most frequently used. Out of its wide range of chillers in cooling only or heat pump version, with or without integrated hydronic components, Daikin always offers you a chiller fitting your application needs.

Air cooled chiller new new new new new new

EWAQ-ACV3 EWAQ-ACW1 EWYQ-ACV3 EWYQ-ACW1 EUWAC-FBZW1 EUWA*-KBZW1 EUWY*-KBZW1 EWAQ-DAYN EWYQ-DAYN EWAD-E-SS EWAD-E-SL EWAD-D-SS EWAD-D-SL EWAD-D-SR

195 196 197 198 199 200 201 202 203 204 205 206 207 208

new new new new

EWAD-D-SX EWAD-D-XS EWAD-D-XR EWAD-D-HS EWAD-BZSS/SL EWAD-BZXS/XL/XR EWYD-BZSS EWYD-BZSL EWAD-C-SS/SL EWAD-C-SR EWAD-C-XS/XL EWAD-C-XR EWAD-C-PS/PL EWAD-C-PR

209 210 211 212 213 214 215 216 217 218 219 220 221 222

For a copy of our latest Price List please call 0845 6419000

194 2515_BOOK_AppliedSystems_2011.indb 194

25/03/2011 08:38


EWAQ-ACV3

EWAQ005-011ACV3

Air cooled mini chiller inverter

Options (factory mounted) • Evaporator heater tape

Strengths • Optimised for use with R-410A • Inverter controlled swing compressor (size 005-007) - Precise temperature control • Inverter controlled scroll compressor (size 009-011) • ESEER up to 4.57 • Cooling operation from 10°C to 46°C (to 43°C for size 005-007) • PE treated condenser coil • Built-in hydraulic module: - No buffer tank required - 2-speed or 3-speed pump • Sound power down to 62dBA • Main switch accessible without removing panels • Refrigerant charge less than 3 kg • Easy ‘plug and play’ installation

Option kit • Digital Input/Output PCP (size 009-011 only) Control • Leaving water control Available inputs • Voltage free contact: - ON/OFF Schedule timer: - ON/OFF - Silent operation

Cooling ONLY Capacity class Cooling capacity Power input EER ESEER Dimensions Weight Water heat exchanger

Nom. Cooling

Unit Unit Type Water volume Nominal water flow Air heat exchanger Type Pump Nominal ESP unit Hydraulic components Expansion vessel Fan Air flow rate Fan motor Speed Sound power level Sound pressure level Compressor Operation range Refrigerant

Water circuit Piping connections Power supply

INVERTER kW kW

Nom.

005 5.2 1.89 2.75 3.75

006 6.0 2.35 2.55 3.83 805x1,190x360 100

HeightxWidthxDepth mm kg

007 7.1 2.95 2.41 3.87

009 8.5 2.74 3.11 4.57

010 9.5 3.19 2.98 4.52 1,435x1,418x382 180

011 11.0 3.82 2.88 4.46

Brazed plate l l/min

Cooling Cooling Volume Cooling Cooling Steps Nom. Nom. Cooling

Nom. Nom.

Cooling Cooling Night quiet mode Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Control Circuits Quantity Piping connections diameter Piping Water heat exchanger inlet / outlet Water heat exchanger drain Phase / Frequency / Voltage

kPa l m³/min rpm dBA dBA dBA °CDB °CDB

17.2 Tube type 45.1 6 -

14.9 49.4

62 48

20.4

24.4

38.3

58.0 96

63 50

Hermetically sealed swing compressor 5~20 10~43

1.01 27.2 Hi-XSS 54.6 10 100 780 8 64 51 45 Hermetically sealed scroll compressor 5~22 10~46

31.5 49.1 97

R-410A kg

1.7

2.95 Electronic expansion valve 1

inch inch

1" MBSP Hose nipple 1/2" FBSP

G 5/4" (female) 5/4" 1~ / 50 / 230

Hz / V

195 2515_BOOK_AppliedSystems_2011.indb 195

25/03/2011 08:38


EWAQ-ACW1

EWAQ009-013ACW1

Air cooled mini chiller inverter

Options (factory mounted) • Evaporator heater tape

Strengths • Optimised for use with R-410A • Precise temperature control • Inverter controlled scroll compressor • ESEER up to 4.68 • Cooling operation from 10°C to 46°C • PE treated condenser coil • Built-in hydraulic module: - No buffer tank required - 2-speed or 3-speed pump • Sound power down to 62dBA • Main switch accessible without removing panels • Refrigerant charge less than 3kg • Easy ‘plug and play’ installation

Option kit • Digital Input/Output PCP Control • Leaving water control Available inputs • Voltage free contact: - ON/OFF Schedule timer: - ON/OFF - Silent operation

Cooling ONLY Indoor units Cooling capacity Power input EER ESEER Dimensions Weight Water heat exchanger

Nom. Cooling

Unit Unit Type Water volume Nominal water flow Air heat exchanger Type Pump Nominal ESP unit Hydraulic components Expansion vessel Fan motor Speed Sound power level Sound pressure level Compressor Operation range Refrigerant

Water circuit Power supply

INVERTER kW kW

Nom.

009 9.0 2.96 3.04 4.68

011 11.0 3.82 2.88 4.63 1,435x1,418x382 180 Brazed plate 1.01 31.5 Hi-XSS 49.1 10 780 8

HeightxWidthxDepth mm kg l l/min

Cooling Cooling Volume Cooling Steps Nom. Nom. Cooling

Cooling Cooling Night quiet mode Type Water side Cooling Air side Cooling Type Charge Control Circuits Quantity Piping connections diameter Piping Phase / Frequency / Voltage

Nom.

kPa l rpm

25.8 56.4

dBA dBA dBA Min.~Max. Min.~Max.

64 51 45

013 13.2 5.10 2.59 4.52

37.8 40.9

66 52 46 Hermetically sealed scroll compressor 5~22 10~46 R-410A 2.95 Electronic expansion valve 1 G 5/4" (female) 5/4" 3N~ / 50 / 400

°CDB °CDB kg

inch inch Hz / V

196 2515_BOOK_AppliedSystems_2011.indb 196

25/03/2011 08:38


EWYQ-ACV3

EWYQ005-011ACV3

Air cooled mini chiller inverter

• • •

Strengths • Optimised for use with R-410A • Inverter controlled swing compressor (size 005-007) - Precise temperature control • Inverter controlled scroll compressor (size 009-011) • ESEER up to 4.57 • COP up to 3.44 • Cooling operation from 10°C to 46°C (to 43 °C for size 005-007) • Heating operation from -15°C to 35°C (to 25 °C for size 005-007) • PE treated condenser coil

Nom. Nom. Cooling Heating

EER COP ESEER Dimensions Weight

Nom. Nom.

Available inputs • Voltage free contact: - ON/OFF - Cooling/Heating changeover • Schedule timer: - ON/OFF - Dual setpoint - Silent operation

Options (factory mounted) • Evaporator heater tape Option kit • Digital Input/Output PCP (size 009-011 only)

HEATING & Cooling Capacity class Cooling capacity Heating capacity Power input

Control • Leaving water control • Setpoint in heating & cooling

Built-in hydraulic module - No buffer tank required - 2-speed or 3-speed pump Sound power down to 62dBA Main switch accessible without removing panels • Refrigerant charge less than 3kg • Easy ‘plug and play’ installation

INVERTER kW kW kW kW

Unit HeightxWidthxDepth mm Unit kg Operation weight kg Water heat exchanger Type Water volume l Nominal water flow Cooling l/min Heating l/min Air heat exchanger Type Pump Nominal ESP unit Cooling kPa Hydraulic components Expansion vessel Volume l Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Fan motor Speed Cooling Nom. rpm Heating Nom. rpm Steps Sound power level Cooling Nom. dBA Heating Nom. dBA Sound pressure level Cooling Nom. dBA Heating Nom. dBA Night quiet mode Cooling dBA Heating dBA Compressor Type Operation range Water side Cooling Min.~Max. °CDB Heating Min.~Max. °CDB Air side Cooling Min.~Max. °CDB Heating Min.~Max. °CDB Refrigerant Type Charge kg Control Circuits Quantity Water circuit Piping connections diameter inch Piping inch Piping connections Water heat exchanger inlet / outlet Water heat exchanger drain Power supply Phase / Frequency / Voltage Hz / V

005 5.2 5.65 1.89 1.97 2.75 2.87

006 6.0 6.35 2.35 2.24 2.55 2.83 805x1,190x360 100 104

007 7.1 7.75 2.95 2.83 2.41 2.74

009 8.5 10.0 2.74 2.91 4.37 3.44 4.57

010 9.5 11.5 3.19 3.38 2.98 3.40 4.52 1,435x1,418x382 180 -

011 11.0 13.0 3.82 3.86 2.88 3.37 4.46

Brazed plate 17.2 19.5 Tube type 45.1 6 -

14.9 17.5 49.4

62

20.4 23.5

24.4 28.7

38.3

58.0 96

63 -

48 48

50 49

Hermetically sealed swing compressor 5~20 25~50 10~43 -15~25

1.01 27.2 33.0 Hi-XSS 54.6 10 100 90 780 760 8 64 64 51 51 45 42 Hermetically sealed scroll compressor 5~22 25~50 10~46 -15~35

31.5 37.3 49.1 97

R-410A 1.7

2.95 Electronic expansion valve 1

1" MBSP Hose nipple 1/2" FBSP

G 5/4" (female) 5/4" 1~ / 50 / 230

197 2515_BOOK_AppliedSystems_2011.indb 197

25/03/2011 08:38


EWYQ-ACW1

EWYQ009ACW1

Air cooled mini chiller inverter

Options (factory mounted) • Evaporator heater tape

Strengths • Optimised for use with R-410A • Precise temperature control • Inverter controlled scroll compressor (size 009-011) • ESEER up to 4.68 • COP up to 3.41 • Heating operation from -15°C to 35°C (to 25 °C for size 005-007) • PE treated condenser coil • Built-in hydraulic module - No buffer tank required - 2-speed or 3-speed pump • Sound power down to 62dBA • Main switch accessible without removing panels • Refrigerant charge less than 3kg • Easy ‘plug and play’ installation

Available inputs • Voltage free contact: - ON/OFF - Cooling/Heating changeover • Schedule timer: - ON/OFF - Dual setpoint - Silent operation

Option kit • Digital Input/Output PCP (size 009-013 only) Control • Leaving water control • Setpoint in heating & cooling

HEATING & Cooling Indoor units Cooling capacity Heating capacity Power input

Nom. Nom. Cooling Heating

Nom. Nom.

INVERTER kW kW kW kW

EER COP ESEER Dimensions Unit HeightxWidthxDepth mm Weight Unit kg Water heat exchanger Type Water volume l Nominal water flow Cooling l/min Heating l/min Air heat exchanger Type Pump Nominal ESP unit Cooling kPa Hydraulic components Expansion vessel Volume l Fan motor Speed Cooling Nom. rpm Heating Nom. rpm Steps Sound power level Cooling Nom. dBA Heating Nom. dBA Sound pressure level Cooling Nom. dBA Heating Nom. dBA Night quiet mode Cooling dBA Heating dBA Compressor Type Operation range Water side Cooling Min.~Max. °CDB Heating Min.~Max. °CDB Air side Cooling Min.~Max. °CDB Heating Min.~Max. °CDB Refrigerant Type Charge kg Control Circuits Quantity Water circuit Piping connections diameter inch Piping inch Power supply Phase / Frequency / Voltage Hz / V

009 9.0 11.0 2.96 3.23 3.04 3.41 4.68

011 11.0 12.5 3.82 3.70 2.88 3.38 4.63 1,435x1,418x382 180 Brazed plate 1.01 31.5 35.8 Hi-XSS 49.1 10 780 760 8

25.8 31.5 56.4

64

013 13.2 14.0 5.10 4.19 2.59 3.34 4.52

37.8 40.1 40.9

66 64

51

52 51

45 42

46 43 Hermetically sealed scroll compressor 5~22 25~50 10~46 -15~35 R-410A 2.95 Electronic expansion valve 1 G 5/4" (female) 5/4" 3N~ / 50 / 400

198 2515_BOOK_AppliedSystems_2011.indb 198

25/03/2011 08:38


Air cooled chiller with centrifugal fan

EUWAC-FBZW1

EUWAC8FBZW1

Air cooled chiller with centrifugal fan

Control • Water inlet temperature control

Strengths • Daikin scroll compressor • Standard reverse phase protection • High fan static pressure (up to 150Pa) • Operation down to -10°C ambient temperature • Pressure gauges

Available inputs / outputs • Input - ON / OFF (per circuit) - Pump / flow switch • Output - Compressor operation - Summary alarm - Pump relay contact

Options (factory mounted) • Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL)

* OPZH: Option LWE high glycol OPZL: Option LWE low glycol

Accessories (kit) • Filter • BMS gateway (MODBUS / J-BUS protocol) • Remote user interface • Hydraulic module (see also EHMC)

Cooling ONLY Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight

Nom. Cooling

Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type - evaporator Minimum water volume in the system Water flow rate Nom. Nominal water Cooling Heat pressure drop exchanger Model Type Quantity Air heat exchanger Type Fan Air flow rate Nom. Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Evaporator water drain Power supply Phase / Frequency / Voltage

kW % kW mm kg kg l l/min kPa

m³/min dBA

5 11.6 5.2 2.23 1,345x856x630 164 166 101 33

10 23.8 9.67 2.46 1,395x1,330x630 261 266 212 68

26

42

48

AC70-24

AC70-34 1 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 109.8 66 Hermetically sealed scroll compressor -10 (OPZL) ~ 21 -10 ~ 43 R-407C Thermostatic expansion valve 1 3.9 FBSP 1" Field installation 3N~ / 50 / 400

AC70-40

70.2 63

°CDB °CDB

kg

8 18.4 100-0 7.66 2.40 1,290x1,180x630 224 228 Brazed plate, one per circuit 153 53

2.1

Hz / V

126 69

4.7

199 2515_BOOK_AppliedSystems_2011.indb 199

25/03/2011 08:38


EUWA*-KBZW1 Air cooled chiller

EUWA*16KBZW1

Options (factory mounted) • Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL) • High ESP fans (50Pa) (OPHF) • Pump size up (OPHP)

Strengths • Optimised for use with R-407C • Integrated hydraulic module (models B and P) • Built-in buffer tank (model B) • Daikin scroll compressor • Standard main isolator switch • Standard water flow switch • Standard filter (delivered as a kit with the unit) • Operation down to -15°C ambient temperature • Standard reverse phase protection • Standard condenser protection grille • Freeze-up protection and prevention • PE treated condenser coil

Accessories (kit) • Refrigerant pressure gauges • Address card and BMS gateway (MODBUS / J-BUS protocol) • Remote user interface • 200l buffer tank • Soft starter (single circuit)

Control • Water inlet temperature control Available inputs / outputs • Input - Remote ON / OFF - Pump contact • Output - Compressor operation - Summary alarm - Pump relay contact

Cooling ONLY Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight

N5 Nom. Cooling

Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Hydraulic components Expansion vessel Volume Fan group Air flow rate Cooling Nom. Fan group 2 Air flow rate Cooling Nom. Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Refrigerant circuit 2 Charge Water circuit Piping connections diameter Piping Power supply Phase / Frequency / Voltage

kW % kW mm kg kg l l/min kPa

l m³/min m³/min dBA

150 152

P5 11.3

B5

N8

N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24 22.5 26.5 34.6 46.6 55.3 0-100 0-50-100 4.48 7.27 8.64 11.50 14.70 17.90 23.80 2.53 2.46 2.60 2.30 2.35 2.60 2.32 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734 168 180 215 229 241 245 259 271 248 262 274 430 448 460 490 508 520 496 514 526 171 239 218 232 300 248 262 330 251 265 335 436 457 525 496 518 545 503 524 592 Brazed plate 1.14 1.615 1.9 2.375 2.964 3.9 4.524 32 51 64 76 99 134 158 24

12 160 (per 2 fans)

P8 19.7

B8

38 -

43

37

22

Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 12 12 12 170 (per 2 fans)

12 -

67

76

3.9

4.6

12

-

12

170 (per 2 fans) 78 79 Hermetically sealed scroll compressor -10 (OPZL) ~ 25 -15 ~ 43 R-407C Thermostatic expansion valve

°CDB °CDB

1 kg kg inch inch Hz / V

-

5.9

6.0

G 1"1/4 (male) 1-1/4"

4.6 4.6

81

2 5.9 5.9 2" male -

6.0 6.0

3N~ / 50 / 400

200 2515_BOOK_AppliedSystems_2011.indb 200

25/03/2011 08:38


EUWY*-KBZW1 Air cooled chiller

EUWY*16KBZW1

Options (factory mounted) • Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL) • High ESP fans (50Pa) (OPHF) • Pump size up (OPHP)

Strengths • Optimised for use with R-407C • Integrated hydraulic module (models B and P) • Built-in buffer tank (model B) • Daikin scroll compressor • Standard main isolator switch • Standard water flow switch • Standard filter (delivered as a kit with the unit) • Operation down to -15°C ambient temperature in cooling mode, down to -10°C in heating mode • Standard reverse phase protection • Standard condenser protection grille • Freeze-up protection and prevention • PE treated condenser coil

Accessories (kit) • Refrigerant pressure gauges • Address card and BMS gateway (MODBUS / J-BUS protocol) • Remote user interface • 200l buffer tank • Soft starter (single circuit)

Control • Water inlet temperature control Available inputs / outputs • Input - Remote ON / OFF - Pump contact - Remote cool / heat selection • Output - Compressor operation - Summary alarm - Pump relay contact

HEATING & Cooling Capacity class Cooling capacity Heating capacity Capacity steps Power input

N5

Nom. Nom. Cooling Heating

EER COP Dimensions Weight

Nom. Nom.

kW kW % kW kW

Unit HeightxWidthxDepth mm Unit kg Operation weight kg Water heat exchanger Type Water volume l Nominal water flow Cooling l/min Heating l/min Nominal water Cooling Filter kPa pressure drop Heating Filter kPa Air heat exchanger Type Hydraulic components Expansion vessel Volume l Fan group Air flow rate Cooling Nom. m³/min Fan group 2 Air flow rate Cooling Nom. m³/min Sound power level Cooling Nom. dBA Compressor Type Operation range Water side Cooling Min.~Max. °CDB Heating Min.~Max. °CDB Air side Cooling Min.~Max. °CDB Heating Min.~Max. °CDB Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit 2 Charge kg Water circuit Piping connections diameter inch Piping inch Power supply Phase / Frequency / Voltage Hz / V

P5 9.1 11.9

B5

N8

P8 17.1 18.5

B8

N10 P10 B10 N12 P12 B12 N16 P16 B16 N20 P20 B20 N24 P24 B24 21.0 25.0 34.2 40 50.0 24.0 27.0 37.0 46 54.0 0-100 0-50-100 3.77 7.38 8.49 11.3 14.8 16.2 22.6 4.56 7.01 8.98 10.7 14.10 17.3 21.4 2.41 2.32 2.47 2.21 2.3 2.5 2.2 2.61 2.64 2.67 2.52 2.62 2.66 2.52 1,230x1,290x734 1,450x1,290x734 1,321x2,580x734 1,541x2,580x734 163 181 193 227 241 253 258 272 284 258 272 284 455 473 485 516 534 546 516 534 546 165 184 252 230 244 312 261 275 343 261 275 343 461 482 550 522 544 612 522 544 612 Brazed plate 1.140 1.615 1.900 2.375 2.964 3.900 4.524 26 49 60 72 98 115 143 34 53 69 77 106 132 155 10 25 24 33 12 19 17 29 31 38 14 16 22 Cross fin coil/Hi-X tubes and PE coated waffle louvre fins 12 12 12 12 12 12 12 160 (per 2 fans) 170 (per 2 fans) 170 (per 2 fans) 67 76 78 79 81 Hermetically sealed scroll compressor -10(OPZL) ~ 20 35 ~ 50 -15 ~ 43 -10 ~ 21 R-407C Thermostatic expansion valve 1 2 4.6 4.7 5.4 5.1 5.4 5.6 5.1 5.4 5.6 G 1"1/4 (male) 2" male 1-1/4" 2" 3N~ / 50 / 400

201 2515_BOOK_AppliedSystems_2011.indb 201

25/03/2011 08:38


EWAQ-DAYN

EWAQ130-150DAYN

Air cooled chiller, multiple scroll

Strengths • Wide capacity range: 80 to 254kW with 8 cooling only models • Optimised for use with R-410A refrigerant • Multiple refrigerant circuits and multiple compressors per circuit • Reliable and efficient scroll with high EER values • Good part load efficiency (seasonal EER) • Anti-corrosion treated aluminium coils • Low operating noise levels • Easy ’plug and play’ installation • Unit dimensions allow easy transport • Fans protected against abnormal operation (4 - 8 fans depending on unit size) • Safety valves in each circuit • Electronic circuit breakers • Electronic expansion valve

• • • • • • • • •

True dual plate brazed plate heat exchanger Sight glass All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at side of unit Increased reliability via 2 independent refrigerant circuits Dual circuit heat exchanger (from >100 kW) Non hermetic filter/dryer Daikin controller (Pcaso) with user friendly and powerful LCD interface

Options (factory mounted) • Single pump contactor (OPSC) • Twin pump contactor (OPTC) • Single pump (OPSP) • Twin pump (OPTP) (1 pump casing, dual motor) • High ESP pump (OPHP) (single pump only) • Buffer tank (OPBT) • Inverter fans (OPIF) (Not available with option OPLN) • Glycol 0°C / -10°C (OPZL) • Dual pressure relief valve (OP03) • Evaporator heater tape (OP10) • Option valves (discharge, liquid line and suction stop valve) • A-meter / V-meter (OP57) • Low Noise (OPLN) (=OPIF + compressor housing) • Condenser protection grills (OPCG)

Cooling ONLY Capacity class Cooling capacity Capacity steps Power input EER ESEER Dimensions Weight

Nom.

Cooling

kW % Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Nominal water flow Cooling Nominal water Cooling Total pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Water heat exchanger inlet / outlet Water heat exchanger drain Power supply Phase / Frequency / Voltage

kW

mm kg kg l/min kPa

m³/min rpm dBA

080 80

100 105

180 210 240 260 182 209 236 254 21/29-43/50/5722/28-40/50/560-25-50-75-100 0-25-50-75-100 0-25-50-75-100 71/79-100 72/78-100 46.6 56.3 64.5 74.6 82.8 94.0 2.81 2.70 2.82 2.80 2.85 2.70 4.34 4.22 4.36 4.32 4.20 4.00 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850 1,500 1,550 1,800 1,850 3,150 3,250 1,517 1,569 1,825 1,877 3,189 3,292 Brazed plate 377 436 522 599 677 728

0-50-100 26.4 36.2 3.03 2.90 4.12 4.00 2,311x2,000x2,566 1,350 1,400 1,365 1,415 229

301

59

58

150 152

52

49

52

53

Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle fins 800 860 1,290 900 970 88 89 90 Scroll compressor -10 (OPZL) ~ 25 -15 ~ 43 R-410A 19 25 29 28 Electronic expansion valve 2 3" OD 1/2"G 3~ / 50 / 400

780 880 86

°CDB °CDB kg

130 131

33 1

Hz / V

51

47 1,600 900 91

39

3"

202 2515_BOOK_AppliedSystems_2011.indb 202

25/03/2011 08:38


EWYQ-DAYN

EWYQ130-150DAYN

Air cooled chiller, multiple scroll

Strengths • Wide capacity range: 77 to 252kW with 8 heat pump models • Optimised for use with R-410A refrigerant • Multiple refrigerant circuits and multiple compressors per circuit • Reliable and efficient scroll with high EER values • Good part load efficiency (seasonal EER) • Anti-corrosion treated aluminium coils • Low operating noise levels • Easy 'plug and play' installation • Unit dimensions allow easy transport • Fans protected against abnormal operation (4 - 8 fans depending on unit size) • Safety valves in each circuit • Electronic circuit breakers • Electronic expansion valve

• • • • • • • • •

True dual plate brazed plate heat exchanger Sight glass All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at side of unit Increased reliability via 2 independent refrigerant circuits Dual circuit heat exchanger (from >100 kW) Non hermetic filter/dryer Daikin controller (Pcaso) with user friendly and powerful LCD interface

Options (factory mounted) • Single pump contactor (OPSC) • Twin pump contactor (OPTC) • Single pump (OPSP) • Twin pump (OPTP) (1 pump casing, dual motor) • High ESP pump (OPHP) (single pump only) • Buffer tank (OPBT) • Inverter fans (OPIF) (Not available with option OPLN) • Glycol 0°C / -10°C (OPZL) • Dual pressure relief valve (OP03) • Evaporator heater tape (OP10) • Option valves (discharge, liquid line and suction stop valve) • A-meter / V-meter (OP57) • Low Noise (OPLN) (=OPIF + compressor housing) • Condenser protection grills (OPCG)

HEATING & Cooling Capacity class Cooling capacity Heating capacity Capacity steps Power input

Nom. Nom.

Cooling Heating

EER COP ESEER Dimensions Weight

kW kW % Nom. Nom.

kW kW

Unit HeightxWidthxDepth mm Unit kg Operation weight kg Water heat exchanger Type Nominal water flow Cooling l/min Heating l/min Nominal water Cooling Total kPa pressure drop Heating Total kPa Air heat exchanger Type Fan Air flow rate Nom. m³/min Speed rpm Sound power level Cooling Nom. dBA Compressor Type Operation range Water side Cooling Min.~Max. °CDB Water side Heating Min.~Max. °CDB Air side Cooling Min.~Max. °CDB Air side Heating Min.~Max. °CDB Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit 2 Charge kg Piping connections Water heat exchanger inlet / outlet Water heat exchanger drain Power supply Phase / Frequency / Voltage Hz / V

080 77 87.7

100 100 114

130 136 149

180 210 230 250 183 211 231 252 199 225.00 258 281 21/29-43/50/5722/28-44/50/560-25-50-75-100 0-25-50-75-100 0-25-50-75-100 71/79-100 72/78-100 47.6 55.7 63.8 75.3 82.2 93.5 49.6 58.8 68.0 77.0 84.2 96.6 2.86 2.60 2.87 2.80 2.81 2.70 3.00 2.81 2.93 2.92 3.06 2.91 4.31 4.07 4.33 4.23 4.20 4.00 2,311x2,000x2,631 2,311x2,000x3,081 2,311x2,000x4,850 1,550 1,600 1,850 1,900 3,200 3,300 1,567 1,619 1,875 1,927 3,239 3,342 Brazed plate, one per unit 390 416 525 605 662 722 427 473 570 645 740 806 43 38 41 44 39 38 51 49 48 50 48 46 Cross fin coil/Hi-Xss tubes and poly ethylene coated waffle fins 800 860 1,290 1,600 900 970 900 88 89 90 91 Scroll compressor -10 (OPZL) ~ 25 25 ~ 50 -15 ~ 43 -10 ~ 21 R-410A Electronic expansion valve 2 22 32 39 22 32 39 3" OD 3" 1/2"G 3~ / 50 / 400

0-50-100 26.5 36.2 30.0 38.1 2.91 2.76 2.92 2.99 4.00 3.81 2,311x2,000x2,566 1,400 1,450 1,415 1,465 221 251

287 327 36

47

46 780 880 86

1 33

37 -

150 145 165

203 2515_BOOK_AppliedSystems_2011.indb 203

25/03/2011 08:38


Air cooled chiller, standard efficiency, standard sound

EWAD-E-SS

EWAD140,160E-SS

Air cooled chiller, standard efficiency, standard sound

• • • • • •

Strengths • Wide capacity range (101kW - 413kW) • Single refrigerant circuit with single screw compressor • Compact design with brazed plate heat exchanger Standard available • Wye delta starter (y - d) • Double setpoint • Fans circuit breakers with thermal overload relays • Phase monitor • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Suction line shut off valve • Low pressure side manometers

• • • • • • • • • • • • • • • • •

Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock

Options (factory mounted) • Total heat recovery • Partial heat recovery • Soft starter • Brine version • Compressor thermal overload relays • Under / Over voltage control • Energy meter • Capacitors for power factor correction

Current limit - display 20 mm evaporator insulation Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Single pump (low or high lift) Twin pump (low or high lift) Not available on sizes 100 and 120 Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation

Cooling ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

100 101

120 121

Hz / V

160 163

180 183

210 214

260 256

310 307

360 360

410 413

68.5 71.7 2.67 2.98 2.81 3.02 2,273x1,292x3,965 2,086 2,116 Plate to plate 24 30 8.74 10.22

86.7 2.95 3.18

111 133 2.77 2.71 3.05 3.23 2,223x2,236x3,070 2,919 2,963

146 2.84 3.34

25 12.22

30 14.65

44 19.74

Stepless 25 38.7 2.61

46.9 2.57

2.93 2,273x1,292x2,165 1,684 1,699

53.4 60.3 2.58 2.70 2.75 2.93 2,273x1,292x3,065 1,861 1,881

12 4.83

15 5.76

17 6.58

24

25

10,922

10,575 91.5 73.5

°CDB °CDB kg

140 138

18

21

20 7.77 24

22

21

High efficiency fin and tube type with integral subcooler 16,383 15,863 21,844 21,150 32,767 920 92.3 93.0 94.2 73.7 73.9 75.1 75.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 23 28 30 33 46 1 3" 3~ / 50 / 400

36 17.21

48

45 31,725 94.5 75.3

95.2 76.0

56

60

204 2515_BOOK_AppliedSystems_2011.indb 204

25/03/2011 08:38


EWAD-E-SL

EWAD130,160E-SL

Air cooled chiller, standard efficiency, low sound

• • • • • •

Strengths • Wide capacity range (97.9kW - 398kW) • Single refrigerant circuit with single screw compressor • Low operating sound levels • Compact design with brazed plate heat exchanger Standard available • Wye delta starter (y - d) • Double setpoint • Fans circuit breakers with thermal overload relays • Phase monitor • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Suction line shut off valve • Low pressure side manometers

• • • • • • • • • • • • • • • •

Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock

Options (factory mounted) • Total heat recovery • Partial heat recovery • Soft starter • Brine version • Compressor thermal overload relays • Under / Over voltage control • Energy meter • Capacitors for power factor correction • Current limit - display

20mm evaporator insulation Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Single pump (low or high lift) Twin pump (low or high lift) Not available on sizes 100 and 120 Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation

Cooling ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

100 97.9

120 116

Hz / V

160 157

180 177

210 209

250 249

300 296

350 345

400 398

67.8 72.1 2.61 2.89 3.07 3.32 2,273x1,292x3,965 2,186 2,216 Plate to plate 24 30 8.47 9.97

84.5 2.95 3.55

110 134 2.69 2.58 3.41 3.34 2,223x2,236x3,070 3,029 3,073

150 2.65 3.45

25 11.90

30 14.15

36 16.50

44 19.01

46

45

44

42

Stepless 25 38.8 47.9 2.52 2.42 3.01 2.97 2,273x1,292x2,165 1,784 1,799

53.0 60.6 2.53 2.60 2.85 3.00 2,273x1,292x3,065 1,961 1,981

12 4.68

17 6.40

15 5.54 23

8,372

8,144 89.0 71.0

°CDB °CDB kg

130 134

18

21

20 7.51

21

20

High efficiency fin and tube type with integral subcooler 12,558 12,217 16,744 16,289 25,117 715 89.8 90.5 91.7 71.2 71.4 72.6 72.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 23 28 30 33 46 1 3" 3~ / 50 / 400

24,433 92.0 72.8

92.7 73.5

56

60

205 2515_BOOK_AppliedSystems_2011.indb 205

25/03/2011 08:38


EWAD-D-SS

EWAD390D-SS

Air cooled chiller, standard efficiency, standard sound

Strengths • Eurovent EER up to 2.93 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 389-578kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops • Four noise level versions standard / low / reduced & quiet. Standard available • Electronic expansion valve • Evaporator heater • Suction stop valve • Main switch

Options (factory mounted) • Glycol application • Single pump • Twin pump • High ESP pump • High ESP twin pump • Total heat recovery • Partial heat recovery • Fan silent • Low ambient • Power factor 0.9 • Gauges • Coil guards

Cooling ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

390 389

440 436

470 466

152 2.56 3.36 2,223x2,234x3,139 2,960 3,090

164 2.66 3.54

167 2.79 3.55

4,030 4,195

4,220

130 18.60

165 20.80

175 22.20

45.6

37.9 32,772

95.8 76.5

96.7

56

60

°CDB °CDB

kg Hz / V

66.5

510 502 Stepless 12.5 184 2.73

530 532

560 556

580 578

194 2.74

205 2.72 3.56

197 2.93 3.39

3.52 2,223x2,234x4,040 4,230 4,395 Single pass shell & tube 165 24.00 25.40 47.1

52.1

High efficiency fin and tube type with integral subcooler 43,694 43,455 43,694 920 96 96.7 98.2 77.0 78.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 70 76 82 139.7mm 3 / 50 / 400

4,235

26.50

160 27.60

57.4

51.2 42,300 98.7 79.0

87

92

206 2515_BOOK_AppliedSystems_2011.indb 206

25/03/2011 08:38


EWAD-D-SL

EWAD400-530D-SL

Air cooled chiller, standard efficiency, low sound

Strengths • Eurovent EER up to 2.78 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 184-533kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops • Four noise level versions standard / low / reduced & quiet. Standard available • Electronic expansion valve • Evaporator heater • Suction stop valve • Main switch

Options (factory mounted) • Glycol application • Single pump • Twin pump • High ESP pump • High ESP twin pump • Total heat recovery • Partial heat recovery • Fan silent • Low ambient • Power factor 0.9 • Gauges • Coil guards

Cooling ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

180 184

200 198

81.4 79.7 2.26 2.48 3.00 3.12 2,355x2,234x2,239 2,475 2,470 2,500 Plate to plate 25 30 8.80 9.40 28.9

21.8

15,300

230 225

250 245

10.70

11.70

100 12.50

13.10

300 320 370 298 321 370 Stepless 12.5 119 123 133 2.50 2.60 2.78 3.20 3.24 3.41 2,223x2,234x3,139 2,960 3,090 Single pass shell & tube 130 14.20 15.30 17.70

84.5 2.66 3.31

93.4 101 108 2.62 2.58 2.54 3.21 3.26 3.23 2,355x2,234x3,139 2,860 2,960

57.8

49.0

53.9

58.9

59.5

14,900

260 261

22,900 900

93.7

94.3 75.0

36

42

48

55.2

67.4

400 404

440 440

510 505

530 533

169 2.39 3.65

195 2.73 3.77

4,029 4,194

170 186 203 2.59 2.57 2.49 3.67 3.57 3.67 2,223x2,234x4,040 4,224 4,229 4,394

165 19.30

21.00

50

88.9

54 114.3

97.2 77.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 58 66

480 477

22.80

165 24.10

160 25.40

47.5

62.1

54.0

48.4

43.4

170

High efficiency fin and tube type with integral subcooler 22,600 22,300 24,428

°CDB °CDB

kg

280 275

33,489 715 94.2 74.5

94.7

70

76 139.7

82

4,234

32,572 95.7 76.0

96.2 76.5

84

86

3 / 50 / 400

Hz/V

207 2515_BOOK_AppliedSystems_2011.indb 207

25/03/2011 08:38


EWAD-D-SR

EWAD400-530D-SR

Air cooled chiller, standard efficiency, reduced sound

Strengths • Eurovent EER up to 2.73 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 177-533kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops • Four noise level versions standard / low / reduced & quiet. Standard available • Electronic expansion valve • Evaporator heater • Suction stop valve • Main switch

Options (factory mounted) • Glycol application • Single pump • Twin pump • High ESP pump • High ESP twin pump • Total heat recovery • Partial heat recovery • Fan silent • Low ambient • Power factor 0.9 • Gauges • Coil guards

COOLING ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

180 177

190 190

84.0 82.7 2.11 2.30 2.89 3.00 2,355x2,234x2,239 2,620 2,650 Plate to plate 25 30 8.50 9.10 26.9

20.1

15,300

220 219

240 238

250 252

85.2 2.57 3.34

94.7 103 111 2.51 2.44 2.38 3.21 3.23 3.16 2,355x2,234x3,139 2,890 3,100

10.40

11.30

100 12.00

55.1

46.6

50.8

14,900

22,900 680

88.7

89.3 70.0

36

42

48

280 310 370 278 312 366 Stepless 12.5 122 125 138 2.28 2.49 2.65 3.13 3.25 3.42 2,223x2,234x3,139 3,110 3,240 Single pass shell & tube 130 13.30 14.90 17.40

12.60 55.2

52.7

65.1

400 404

440 440

510 505

530 533

169 2.39 3.65

195 2.73 3.77

4,040 4,342

170 186 203 2.59 2.57 2.49 3.67 3.57 3.67 2,223x2,234x4,040 4,240 4,542

165 19.30

21.00

50

88.9

54

92.2 72.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 58 66 2

22.80

165 24.10

160 25.40

47.5

62.1

54.0

48.4

43.4

33,489 715 90.7 71.0

89.7

114.3

480 477

170

High efficiency fin and tube type with integral subcooler 22,600 22,300 24,428

°CDB °CDB kg

270 265

70

76

82

32,572 92.2 72.5

92.7 73.0

84

86

139.7 3 / 50 / 400

Hz / V

208 2515_BOOK_AppliedSystems_2011.indb 208

25/03/2011 08:38


EWAD-D-SX

EWAD230-410D-SX

Air cooled chiller, standard efficiency, extra low sound

Strengths • Eurovent EER up to 2.71 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 203-492kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops • Four noise level versions standard / low / reduced & quiet. Standard available • Electronic expansion valve • Evaporator heater • Suction stop valve • Main switch

Options (factory mounted) • Glycol application • Single pump • Twin pump • High ESP pump • High ESP twin pump • Total heat recovery • Partial heat recovery • Fan silent • Low ambient • Power factor 0.9 • Gauges • Coil guards

Cooling ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

210 203

230 231

250 253

270 271

79.9 2.54 3.39 2,420x2,234x3,139 3,110 3,200

85.2 2.71 3.63

93.5 2.70 3.52

104 2.59 3.55

3,475

3,425

310 309

370 370

410 413

450 451

11.00

44.7

33.8

490 492

136 2.27 3.25

148 2.49 3.24

169 2.44 3.49

3,560 3,735

4,302 4,472

173 187 2.60 2.63 3.61 3.58 2,420x2,234x4,940 4,506 4,581 4,676 4,746

12.10

165 12.90

Single pass shell & tube 160 13.70 14.30 14.70

175 17.70

19.70

21.50

165 23.50

38

38.3

34.9

44.5

43.9

50

44.8

25,933

28,625

33,116

85.7 65.5

86.2 66.0

76

82

115

37.7

40.5

High efficiency fin and tube type with integral subcooler 17,200 26,495 500 84.7 65.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 60 65 114.3 3 / 50 / 400

17,900

84.3

°CDB °CDB

kg

300 299 Stepless 12.5 114 126 2.50 2.37 3.44 3.39 2,420x2,234x4,040 3,430 3,590

90 9.70

12,900

290 286

56

Hz / V

170

70 139.7

209 2515_BOOK_AppliedSystems_2011.indb 209

25/03/2011 08:38


EWAD-D-XS

EWAD250D-XS

Air cooled chiller, high efficiency, standard sound

Strengths • High efficiency levels • Eurovent EER up to 3.2 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 247–622kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops

Options (factory mounted) • Glycol application • Total heat recovery • Partial heat recovery • Fan silent • Power factor 0.9 • Gauges • Coil guards

Standard available • Evaporator heater • Suction stop valve • Electronic expansion valve • Main switch

Cooling ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

250 247

280 275

300 302

330 327

79.1 3.12 3.56 2,355x2,234x3,138 2,905 3,000

87.1 3.16 3.60

94.1 3.20 3.62

380 376 Stepless 12.5 120 3.14 3.58

400 401

95 11.80

13.10

14.40

104 113 127 3.15 3.12 3.16 3.85 3.67 3.59 2,355x2,234x4,040 3,235 3,240 3,400 Single pass shell & tube 165 160 15.60 16.70 17.90 19.10

48.1

44.9

48.8

46.1

22,300

3,285

115

50.8

57.6

63.5

470 469

520 524

150 3.12 3.84 2,223x2,234x4,040 3,510 3,780

166 3.15 4.00

30,600

96.8

66

620 622

181 194 3.18 3.20 4.01 3.88 2,223x2,234x4,940 4,670 4,685 4,940

270

255 25.00

27.40

29.70

47.4

62.9

56.2

37.9

77.5

58

580 575

22.40

High efficiency fin and tube type with integral subcooler 29,700 44,000 43,000 43,695 900 97.2 98.7

54,616 920 99.2 79.0

°CDB °CDB

kg

350 351

76 114.3

Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 73 76

86

100 168.3

3 / 50 / 400

Hz / V

210 2515_BOOK_AppliedSystems_2011.indb 210

25/03/2011 08:38


EWAD-D-XR

EWAD270-390D-XR

Air cooled chiller, high efficiency, reduced sound

Strengths • High efficiency levels • Reduced sound levels • Eurovent EER up to 3.12 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 243–600kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops

Options (factory mounted) • Glycol application • Total heat recovery • Partial heat recovery • Fan silent • Power factor 0.9 • Gauges • Coil guards

Standard available • Evaporator heater • Suction stop valve • Electronic expansion valve • Main switch

Cooling ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

240 243

270 272

300 296

80.6 3.01 3.63 2,355x2,234x3,138 3,005 3,100

87.0 3.12 3.70

95.1 3.11 3.69

320 322

370 370 Stepless 12.5 119 3.12 4.01

390 394

95 11.60

13.00

14.10

106 115 127 3.05 2.99 3.10 3.82 3.71 3.82 2,355x2,234x4,040 3,335 3,340 3,500 Single pass shell & tube 165 160 15.40 16.40 17.70 18.80

46.7

44.0

47.5

44.7

3,385

115

49.2

56.2

55.6

91.8 72.5

60

460 455

510 512

152 2.99 3.89 2,223x2,234x4,040 3,610 3,880

167

560 561

600 600

183 198 3.07 3.03 4.11 3.93 2,223x2,234x4,940 4,770 4,785 5,040

270

255

21.70

24.40

26.80

28.60

44.8

60.4

53.7

36.1

High efficiency fin and tube type with integral subcooler 12,500 33,488 680 92.2 93.2

41,861

41,864 715 93.7

73.5 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 80

°CDB °CDB

kg

350 345

68 114.3

104 168.3

3 / 50 / 400

Hz/V

211 2515_BOOK_AppliedSystems_2011.indb 211

25/03/2011 08:38


EWAD-D-HS

EWAD340-450D-HS

Air cooled chiller, high ambient

Strengths • High ambient mode HS • Eurovent EER up to 3.07 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 195–587kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops

Options (factory mounted) • Glycol application • Total heat recovery • Partial heat recovery • Fan silent • Power factor 0.9 • Gauges • Coil guards

Standard available • Evaporator heater • Suction stop valve • Electronic expansion valve • Main switch

Cooling ONLY Capacity Class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Fan motor Speed Cooling Nom. Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW

mm kg kg l l/s kPa

l/s rpm dBA dBA

200 195

210 208

230 234

77.2 75.5 2.52 2.76 3.11 3.26 2,223x2,234x2,239 2,475 2,470 2,500 Plate to plate 25 30 9.30 9.90

83.0

11.10

12.20

13.10

90 13.80

31.5

46.1

52.1

53.7

59.3

23.7

23,900

22,800

260 256

290 289

310 306

97.7 104 2.80 2.78 3.34 3.21 3.30 3.28 2,223x2,234x3,339 2,865 2,870 2,960

112 2.73 3.27

91.0

2.81

95

35,900

95.7

°CDB °CDB

kg

36

42 88.9

Hz / V

270 274

44

340 336 Stepless 12.5 120 2.80 3.25

380 381

420 415

14.60

127 141 150 162 175 182 191 3.00 2.94 2.98 2.95 2.94 3.00 3.07 3.57 3.61 3.68 3.66 3.71 3.79 2,223x2,234x4,040 2,223x2,234x4,940 3,185 3,277 3,942 4,356 4,361 4,366 3,300 3,447 4,112 4,526 Single pass shell & tube 115 170 165 160 16.00 18.20 19.80 21.40 22.80 24.50 26.10 28.00

64.4

58.3

69.9

45.8

450 448

52.5

High efficiency fin and tube type with integral subcooler 35,000 34,100 47,900 43,694 42,300 900 96.3 96.7 98.7 96.7 77.0 79.0 77.0 Semi-hermetic single screw compressor -15~15 -18~48 R-134a 2 55 56 58 66 70 90 114.3 3 / 50 / 400

480 478

510 514

58.0

50.9

550 547

55.7

590 587

52.6

54,616 920 97.7 77.5

99.2 79.0

95

100

99.7 79.5

139.7

212 2515_BOOK_AppliedSystems_2011.indb 212

25/03/2011 08:38


EWAD-BZSS/SL

EWAD330,360BZS(S,L)

Air cooled inverter chiller, standard efficiency, standard/low sound

Strengths • ESEER up to 4.70 • All models are PED pressure vessel approved • Inverter stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 329~515kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Quick start-up • Standard electronic expansion valve • Power factor > 0.95 Standard available • Double setpoint • Fans thermal relays • Phase monitor • Inverter compressor starter • Evaporator victaulic kit • Fan silent mode • Fan speed regulation • Evaporator electric heater

• • • • • • •

Electronic expansion valve Discharge line shut off valve Suction line shut off valve Low pressure side manometers Hour run meter General fault contactor Main switch interlock

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP pump • High ESP twin pump • Double pressure relief valve with diverter • Refrigerant high pressure side gauge • Coil guards • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

Cooling ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (SS)

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Weight (SL) Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level (SS) Cooling Nom. Sound power level (SL) Cooling Nom. Sound pressure level (SS) Cooling Nom. Sound pressure level (SL) Cooling Nom. Compressor Type Operation range Water side Cooling Min.~Max. Air side Cooling Min.~Max. Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

INVERTER kW % kW

mm kg kg kg kg l l/s kPa

l/s rpm dBA dBA dBA dBA

330 329

360 358

400 395

120.0 136 2.74 2.63 4.59 4.60 2,355x2,234x4,381 4,190 4,440 4,340 4,590 271 15.72

17.10

264

60

61

72

67

460 459

490 488

520 515

168 2.73 4.57

181 2.70 4.70 2,355x2,234x6,181 4,990 5,240 5,140 5,390

193 2.67 4.60

21.93

23.32

24.61

78

69

76

248

High efficiency fin and tube type with integral subcooler 40,833 700 103.2 97.3

32,667 102.8 96.9 83.0 77.0

Semi-hermetic single screw compressor -9.5~15 -10~45 R-134a 99 105 114 2 168.3mm 3~ / 50 / 400

°CDB °CDB kg

420 423 Stepless 13.5 147 159 2.69 2.66 4.55 4.59 2,355x2,234x5,281 4,590 4,840 4,740 4,990 Single pass shell & tube 256 18.87 20.21

73

Hz / V

49,000 103.6 98.2 83.5 77.5

118

121

213 2515_BOOK_AppliedSystems_2011.indb 213

25/03/2011 08:38


EWAD-BZXS/XL/XR

EWAD330,360BZX(S,L,R)

Air cooled inverter chiller, high efficiency, standard/low/reduced sound

Strengths • ESEER up to 5.01 • All models are PED pressure vessel approved • Inverter stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 329~515kW • 2 truly independent refrigerant circuits • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Quick start-up • Standard electronic expansion valve • Power factor > 0.95

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP pump • High ESP twin pump • Double pressure relief valve with diverter • Refrigerant high pressure side gauge • Coil guards • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

Standard available • Double setpoint • Fans thermal relays • Phase monitor • Inverter compressor starter • Evaporator victaulic kit • Fan silent mode • Fan speed regulation • Evaporator electric heater • Electronic expansion valve • Discharge line shut off valve • Suction line shut off valve • Low pressure side manometers • Hour run meter • General fault contactor • Main switch interlock

Cooling ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions Weight (XS) Weight (XL) Weight (XR) Water heat exchanger

Air heat exchanger Fan Sound power level (XS) Sound pressure level (XS) Sound power level (XL) Sound pressure level (XL) Sound power level (XR) Sound pressure level (XR) Compressor Operation range Refrigerant

Piping connections Power supply

INVERTER

Nom. Method Minimum capacity Cooling Nom.

kW

Unit HeightxWidthxDepth Unit Operation weight Unit Operation weight Unit Operation weight Type Water volume Nominal water flow Cooling Nominal water Cooling Heat pressure drop exchanger Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Cooling Nom. Type Water side Cooling Min.~Max. Air side Cooling Min.~Max. Type Charge Circuits Quantity Evaporator water inlet/outlet Phase / Frequency / Voltage

mm kg kg kg kg kg kg

% kW

l l/s kPa

l/s rpm dBA dBA dBA dBA dBA dBA

330 329

360 358

400 395

118.0 135 2.79 2.65 4.79 4.82 2,355x2,234x4,381 4,190 4,440 4,340 4,590 4,390 4,640 271 15.72

17.10

264

60

61

72

67

460 459

490 488

520 515

165 2.78 4.81

178 2.74 5.01 2,355x2,234x6,181 4,990 5,240 5,140 5,390 5,190 5,440

190 2.71 4.84

21.93

23.32

24.61

78

69

76

248

High efficiency fin and tube type with integral subcooler 40,833 700 103.2

32,667 102.8 83.0 96.9

97.3 77.0

92.9

93.3 73.0 Semi-hermetic single screw compressor -9.5~15 -10~45 R-134a 99 105 114 2 168.3 3~ / 50 / 400

°CDB °CDB kg

420 423 Stepless 13 145 157 2.72 2.69 4.78 4.84 2,355x2,234x5,281 4,590 4,840 4,740 4,990 4,790 5,040 Single pass shell & tube 256 18.87 20.21

73

Hz / V

49,000 103.6 83.5 98.2 77.5 94.2 73.5

118

121

214 2515_BOOK_AppliedSystems_2011.indb 214

25/03/2011 08:38


EWYD-BZSS

EWYD260BZSS

Air cooled heat pump inverter chiller, standard efficiency, standard sound

Strengths • Optimised for use with R-134a • Cooling range: 254 - 583kW • Heating range: 270 - 615kW • EER range up to 2.87 • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Seasonal quietness • Low starting current • No gas boiler required • Optimised defrost cycles • Optimum ESEER values • PID microprocessor control • Power factor up to 0.95 • 2-3 truly independent refrigerant circuits • Standard operation range down to -12°C

Standard available • Double setpoint • Fans thermal relays • Phase monitor • Inverter compressor starter • Evaporator electric heater • Discharge line shut off valve • Suction line shut off valve • Low pressure side manometers • Hour run meter • General fault contactor Options • Partial heat recovery • Fan silent mode • Double pressure relief valve with diverter • Condenser coil guards • Spring Anti Vibration Mounts

HEATING & COOLING Capacity class Cooling capacity Heating capacity Capacity control Power input

Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.

EER COP ESEER Dimensions Weight

INVERTER kW kW % kW kW

Unit HeightxWidthxDepth mm Unit kg Operation weight kg Water heat exchanger Type Water volume l Nominal water flow Cooling l/s Heating l/s Nominal water Cooling Heat kPa pressure drop exchanger Heating Heat kPa exchanger Air heat exchanger Type Fan Air flow rate Nom. l/s Speed rpm Sound power level Cooling Nom. dBA Heating Nom. dBA Sound pressure level Cooling Nom. dBA Heating Nom. dBA Compressor Type Operation range Water side Cooling Min.~Max. °CDB Air side Cooling Min.~Max. °CDB Refrigerant Type Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage Hz / V

250 254 270

270 273 297

290 292 324

320 324 333

90.3 100 109 90.4 99 107 2.81 2.74 2.69 2.98 2.99 3.03 4.05 4.04 4.01 2,335x2,254x3,547 3,410 3,455 3,500 3,550 3,595 3,640

340 339 349

370 365 379

380 382 410 Stepless

410 413 443

13 124 134 142 152 163 124 132 141 155 165 2.74 2.73 2.68 2.72 2.68 2.80 2.87 2.90 2.85 2.81 4.01 4.02 3.94 4.03 4.01 2,335x2,254x4,381 2,335x2,254x5,281 3,870 3,940 4,010 4,390 4,010 4,068 4,138 4,518 Single pass shell & tube 133 128 15.46 16.21 17.42 18.25 19.72 20.81 15.89 16.66 18.11 19.57 21.15 22.14 116 117 2.79 2.84 4.07

12.12 12.89

138 13.03 14.18

13.94 15.49

37

42

48

53

58

53

57

46

42

49

58

55

60

57

65

52

100.5 100.5 82.1 82.1

94

100

460 457 475

510 505 530

161 164 2.83 2.90 4.31

178 176 2.83 3.02

520 522 558

580 583 615

186 184 2.81 3.04

215 205 2.71 3.00 4.05

9

5,015 5,255

4.13 2,335x2,254x6,583 5,495 5,735 5,724 5,964 5,953

240 21.83 22.68

24.11 25.33

24.92 26.65

218 27.87 29.39

51

61

50

53

65

57

66

55

60

71

High efficiency fin and tube type with integral subcooler 42,304 52,880 920 101.2 101.8 101.2 101.8 82.3 82.5 82.3 82.5 Semi-hermetic single screw compressor -8~15 -10~45 R-134a 118 121.0 124 148 2 139.7 3~ / 50 / 400

31,728

88

440 436 463

229

63,456 103.6 103.6 83.7 83.7

177

183

186

3 219.1mm

215 2515_BOOK_AppliedSystems_2011.indb 215

25/03/2011 08:38


EWYD-BZSL

EWYD260BZSL

Air cooled heat pump inverter chiller, standard efficiency, low sound

Strengths • Optimised for use with R-134a • Cooling range: 248 - 567kW • Heating range: 270 - 615kW • EER range up to 2.87 • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Seasonal quietness • Low starting current • No gas boiler required • Optimised defrost cycles • Optimum ESEER values • PID microprocessor control • Power factor up to 0.95 • 2-3 truly independent refrigerant circuits • Standard operation range down to -12°C • Low operating sound levels

Standard available • Double setpoint • Fans thermal relays • Phase monitor • Inverter compressor starter • Fans speed control device • Evaporator electric heater • Discharge line shut off valve • Suction line shut off valve • Low pressure side manometers • Hour run meter • General fault contactor Options • Partial heat recovery • Double pressure relief valve with diverter • Condenser coil guards • Spring Anti Vibration Mounts

HEATING & COOLING Capacity class Cooling capacity Heating capacity Capacity control Power input

Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.

EER COP ESEER Dimensions Weight

INVERTER kW kW % kW kW

Unit HeightxWidthxDepth mm Unit kg Operation weight kg Water heat exchanger Type Water volume l Nominal water flow Cooling l/s Heating l/s Nominal water Cooling Heat kPa pressure drop exchanger Heating Heat kPa exchanger Air heat exchanger Type Fan Air flow rate Cooling Nom. l/s Heating Nom. l/s Fan motor Speed Cooling Nom. rpm Heating Nom. rpm Sound power level Cooling Nom. dBA Heating Nom. dBA Sound pressure level Cooling Nom. dBA Heating Nom. dBA Compressor Type Operation range Water side Cooling Min.~Max. °CDB Air side Cooling Min.~Max. °CDB Refrigerant Type Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage Hz / V

250 248 270

270 266 297

290 291 324

88.5 98 109 90.4 99 107 2.80 2.70 2.66 2.98 2.99 3.03 4.18 4.16 4.11 2,335x2,254x3,547 3,750 3,795 3,840 3,888 3,933 3,978

320 316 333

370 372 410 Stepless

400 403 443

430 425 463

13 122 132 142 149 161 124 132 141 155 165 2.72 2.68 2.62 2.71 2.64 2.80 2.87 2.90 2.85 2.81 4.18 4.16 4.13 4.19 4.14 2,335x2,254x4,381 2,335x2,254x5,281 4,210 4,280 4,350 4,730 4,343 4,408 4,478 4,858 Single pass shell & tube 133 128 15.12 15.83 16.98 17.77 19.28 20.30 15.89 16.66 18.11 19.57 21.15 22.14

138 12.70 14.18

13.89 15.49

36

40

48

51

42

49

58

55

94.0 94.9 75.6 76.5

100

450 448 475

156 164 2.87 2.90 4.31 5,525 5,765

490 493 530

510 510 558

570 567 615

9 174 183 214 176 184 205 2.83 2.79 2.65 3.02 3.04 3.00 4.29 4.23 4.10 2,335x2,254x6,583 6,005 6,245 6,234 6,474 6,463

240 21.39 22.68

23.56 25.33

229 24.34 26.65

218 27.11 29.39

55

50

55

44

48

59

48

51

62

60

57

65

52

57

66

55

60

71

High efficiency fin and tube type with integral subcooler 32,576 40,720 42,304 52,880 715 920 94.7 95.3 96.1 96.7 75.8 76.0 77.2 77.4 Semi-hermetic single screw compressor -8~15 -10~45 R-134a 118 121 124 148 2 139.7 3 ~/ 50 / 400

24,432 31,728

94

360 355 379

113 117 2.79 2.84 4.29

11.83 12.89

88

330 331 349

48,864 63,456

97.0 98.4 77.2 78.6

177

183

186

3 219.1mm

216 2515_BOOK_AppliedSystems_2011.indb 216

25/03/2011 08:38


EWAD-C-SS/SL

EWAD-C-

Air cooled chiller, standard efficiency, standard/low sound

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • 11 sizes to cover a range from 647 up to 1,922kW • EER range up to 2.99 • 2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Partial and heat recovery option available • New MicroTech III controller

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP fans • Fan silent • Low ambient • Power factor 0.9 • Dual pressure relief valve • Suction line shut off valve • A/V meter • Condenser coil guards • Soft starter • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

Standard available • Wye Delta Starter (Y - D) • Double setpoint • Fans thermal relays • Phase monitor • Evaporator victaulic kit • 20mm Evaporator insulation • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock • Emergency stop

COOLING ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions

Nom. Method Minimum capacity Cooling Nom.

Unit

650 647

740 744

830 832

910 912

970 967

221 2.93 3.95

262 2.84 3.87

299 2.78 3.89

318 2.87 3.84

12.5 351 2.76 3.8

kg kg kg kg

5,630 5,910 5,920 6,200

5,740 5,990 6,030 6,280

5,760 6,010 6,050 6,300

6,280 6,530 6,570 6,820

6,560 6,810 6,850 7,100

l l/s kPa

30.9

266 35.56

39.74

251 43.6

46.21

52

61

68

kW % kW

HeightxWidthxDepth mm

Weight (SS)

Unit Operation weight Weight (SL) Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. (SS) Sound pressure level (SS) Cooling Nom. Sound power level Cooling Nom. (SL) Sound pressure level (SL) Cooling Nom. Compressor Type Operation range Water side Cooling Air side Cooling Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

Heat exchanger

l/s rpm dBA

Min.~Max. Min.~Max.

2,540x2,285x6,185

73

59 53,444

64,133 101.1

C11 1,064

63

100.0

100.9

79.0

79.5

80.4

96.0

96.1

97.5

97.1

97.6

dBA

75.5

75.6

76.5

76.6

76.8

146

144 2

128

C14 1,419

C15 1,538

C16 1,622

72

54

58

47

59

C17 1,714

65

73

High efficiency fin and tube type with integral subcooler 74,822 85,510 96,199 106,888 920

99.5

101.5

101.7

80.6

°CDB °CDB

C13 H14 1,319 1,418 Stepless

C18 1,802

7 378 402 441 474 500 551 580 618 665 2.82 2.86 2.99 2.84 2.79 2.8 2.77 2.71 3.88 3.84 4.08 4.07 3.88 3.9 3.87 3.78 3.79 2,540x2,285 2,540x2,285 2,540x2,285x8,885 2,540x2,285x10,185 2,540x2,285x11,085 x7,085 x7,985 7,010 7,280 7,900 10,310 10,320 10,710 10,770 11,240 7,250 7,520 8,280 10,730 11,110 11,260 12,110 7,300 7,570 8,190 10,750 10,770 11,150 11,210 11,680 7,540 7,810 8,570 11,170 11,550 11,700 12,560 Single pass shell & tube 243 386 421 408 474 50.85 55.04 62.9 67.7 67.78 73.5 77.51 81.89 86.00

dBA dBA

kg

C12 1,152

98.1

101.9

102.9

80.7

81.0

98.2

103.0

117,577 103.2

99.1

C20 1,922

682 2.75 3.81

714 2.69 3.77

2,540x2,285x11,985 11,600 12,480 12,040 12,920 850 89.50

91.70

39

40

128,266

103.3

103.5

103.7

81.2

81.5

81.9

99.9

101

77.9

78

275

305

81.1

76.9 77 77.2 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 46 R-134a 162 178 196 260

36

C19 1,875

99.5 77.3

77.4

261 3

168.3mm

219.1mm

273mm

3 / 50 / 400

Hz / V

217 2515_BOOK_AppliedSystems_2011.indb 217

25/03/2011 08:38


EWAD-C-SR

EWAD-C-

Air cooled chiller, standard efficiency, reduced sound

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • 11 sizes to cover a range from 647 up to 1,714 kW • EER range up to 2.93 • 2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Partial and heat recovery option available • New MicroTech III controller

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP fans • Fan silent • Low ambient • Power factor 0.9 • Dual pressure relief valve • Suction line shut off valve • A/V meter • Condenser coil guards • Soft starter • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

Standard available • Wye Delta Starter (Y - D) • Double setpoint • Fans thermal relays • Phase monitor • Evaporator victaulic kit • 20 mm Evaporator insulation • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock • Emergency stop

COOLING ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions

Nom. Method Minimum capacity Cooling Nom.

Unit

kW % kW

620 619

720 715

790 789

880 876

920 922

C10 1,020

C11 1,112

C12 H14 1,270 1,321 Stepless

C13 1,367

C14 1,471

C15 1,556

C14 1,623

C17 1,714

C18 1,795

C19 1,833

223 2.77 4.08

272 2.62 3.96

315 2.51 3.98

331 2.65 3.99

12.5 369 2.5 4

395 2.59

417 2.67

457 2.78 4.12

517 2.64 3.9

576 2.55 3.87

603 2.58 3.9

7 647 2.51 3.83

702 2.44 3.79

718 2.50 3.82

757 2.42 3.77

HeightxWidthxDepth mm

Weight

Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Air side Cooling Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

Heat exchanger

kg kg

5,920 6,200

6,030 6,280

6,050 6,300

6,750 6,820

l l/s kPa

266 29.57 34.15

37.71

251 41.83

47

57

l/s rpm dBA dBA Min.~Max. Min.~Max.

2,540x2,285x6,185

67

55 41,006

91.5 71.0

92.0 71.5

3.96 2,540x2,285 2,540x2,285 2,540x2,285x8,885 2,540x2,285x10,185 2,540x2,285x11,085 x7,085 x7,985 6,850 7,300 7,570 8,190 10,750 10,770 11,150 11,210 11,680 7,100 7,540 7,810 8,570 11,170 11,550 11,700 12,560 Single pass shell & tube 243 386 421 408 474 44.05 48.75 53.11 60.67 63.11 65.32 70.28 74.32 77.57 81.80 62

49,207 92.5 72

93.0 72.5

°CDB °CDB kg

128

495 2.67 4.00

144 2 168.3mm

Hz / V

58

68

50

54

44

54

60

66

High efficiency fin and tube type with integral subcooler 57,408 65,610 73,811 82,012 90,213 715 93.5 93.8 94 94.8 94.9 95.1 95.2 72.6 72.7 72.9 73.0 73.1 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 46 R-134a 162 178 196 260 261 3 219.1mm 3 / 50 / 400

33 90,216 95.5 73.4

275

2,540x2,285x11,985 12,040 12,920 850 85.60

87.50

36

37

98,417 95.9 73.7

74

305 273mm

218 2515_BOOK_AppliedSystems_2011.indb 218

25/03/2011 08:38


EWAD-C-XS/XL

EWAD-C-

Air cooled chiller, high efficiency, standard/low sound

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • 11 sizes to cover a range from 760 up to 2,008kW • EER range up to 3.29 • 2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Partial and heat recovery option available • New MicroTech III controller

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP fans • Fan silent • Low ambient • Power factor 0.9 • Dual pressure relief valve • Suction line shut off valve • A/V meter • Condenser coil guards • Soft starter • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

Standard available • Wye Delta Starter (Y - D) • Double setpoint • Fans thermal relays • Phase monitor • Evaporator victaulic kit • 20 mm Evaporator insulation • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock • Emergency stop

COOLING ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions

Nom. Method Minimum capacity Cooling Nom.

Unit

kW % kW

HeightxWidthxDepth mm

Weight (XS)

Unit Operation weight Weight (XL) Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Fan motor Speed Cooling Sound power level (XL) Cooling Nom. Sound pressure Cooling Nom. level (XL) Sound power level (XL) Cooling Nom. Sound pressure Cooling Nom. level (XL) Compressor Type Operation range Water side Cooling Air side Cooling Refrigerant Type Charge Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kg kg kg kg

Heat exchanger

Nom.

Min.~Max. Min.~Max.

l l/s kPa

760 756

830 830

890 889

233 3.25 4.02 2,540x2,285 x6,185 5,990 6,240 6,280 6,520

253 278 3.28 3.2 4.11 4.02 2,540x2,285 x7,085 6,340 6,360 6,580 6,600 6,630 6,650 6,870 6,890

251 36.1

243 39.67 42.49

80

56

64

990 C10 C11 C12 C13 H14 H15 C14 C15 C16 1,001 1,074 1,196 1,280 1,349 1,415 1,525 1,409 1,526 1,596 Stepless 12.5 307 338 364 400 411 444 475 437 474 504 3.26 3.18 3.29 3.2 3.29 3.19 3.21 3.23 3.22 3.17 4.11 4.05 4.14 4.02 4.28 4.31 4.35 4.23 4.19 4.17 2,540x2,285 2,540x2,285x9,785 2,540x2,285x11,985 x7,985 7,190 7,470 8,220 8,240 8,900 10,560 11,310 11,570 7,600 7,870 8,610 8,630 9,890 11,040 12,170 12,430 7,480 7,760 8,510 8,530 9,190 11,000 11,760 12,010 7,880 8,160 8,900 8,920 10,180 11,490 12,610 12,870 Single pass shell & tube 403 386 979 491 850 47.82 51.32 57.13 61.18 64.45 67.50 72.86 67.34 72.9 76.24 61

69

45

51

71

77

64,133

80.2

80.7

80.3

80.4

dBA dBA

96.8

97.4

98

98.2

98.8

98.9

76.3

76.5

76.9

77.1

76.7

76.8

100.2

100.5 79.7

°CDB °CDB kg

146

162

77

57

533 3.16 4.16 2,540x2,285 x12,885 11,900 12,760 12,350 13,200

871 850 80.48 84.47 88.79 90.77 93.2

62

68

182

214

80.5

80.7

80.9

168.3

64

37

77.1

77.2

100 77.3

312

219.1 3~ / 50 / 400

248 273 3 / 50 / 400

43

100.4

77

328 3

77.5

343

219.1

95.8

41

81 100.2

77.4

Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 50 R-134a 225 291 297

39

160,332 920 103.9

80.8

99.6

2 kg mm Hz / V

7 561 590 615 642 672 3.15 3.09 3.04 2.99 4.13 4.12 4.03 4.01 2,540x2,285 2,540x2,285x14,685 x13,785 12,260 12,600 13,140 13,470 12,700 13,040 13,580 13,910

High efficiency fin and tube type with integral subcooler 85,510 106,888 128,266 138,954 149,643 920 920 920 101.4 101.9 102.4 102.5 102.9 103.1 103.2 103.5 103.7

l/s rpm rpm dBA dBA

74,822

84

C17 C18 C19 C20 C21 C22 1,685 1,768 1,858 1,901 1,953 2,008

343

273 3~ / 50 / 400

3 / 50 / 400

219 2515_BOOK_AppliedSystems_2011.indb 219

25/03/2011 08:38


EWAD-C-XR

EWAD-C-

Air cooled chiller, high efficiency, reduced sound

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • 11 sizes to cover a range from 736 up to 1959kW • EER range up to 3.2 • 2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Partial and heat recovery option available • New MicroTech III controller

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP fans • Fan silent • Low ambient • Power factor 0.9 • Dual pressure relief valve • Suction line shut off valve • A/V meter • Condenser coil guards • Soft starter • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

Standard available • Wye Delta Starter (Y - D) • Double setpoint • Fans thermal relays • Phase monitor • Evaporator victaulic kit • 20mm Evaporator insulation • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock • Emergency stop

COOLING ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions

Nom. Method Minimum capacity Cooling Nom.

Unit

kW % kW

HeightxWidthxDepth mm

Weight

Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Air side Cooling Refrigerant Type Charge Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kg kg

Heat exchanger

l l/s kPa

l/s rpm dBA dBA Min.~Max. Min.~Max.

740 736

C10 C11 C12 C13 H14 H15 C14 C15 C16 C17 1,041 1,168 1,247 1,302 1,367 1,468 1,378 1,486 1,550 1,639 Stepless 12.5 235 254 281 309 343 365 404 415 454 491 438 479 513 541 3.14 3.2 3.08 3.15 3.03 3.2 3.08 3.14 3.01 2.99 3.15 3.1 3.03 4.29 4.36 4.23 4.34 4.24 4.38 4.25 4.33 4.38 4.43 4.34 4.26 4.2 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285 2,540x2,285x9,785 2,540x2,285x11,985 x6,185 x7,085 x7,985 x12,885 6,280 6,630 6,650 7,480 7,760 8,510 8,530 9,190 11,000 11,760 12,010 12,350 6,520 6,870 6,890 7,880 8,160 8,900 8,920 10,180 11,490 12,610 12,870 13,200 Single pass shell & tube 251 243 403 386 979 491 850 35.17 38.74 41.36 46.54 49.76 55.78 59.56 62.21 65.20 70.00 65.85 70.98 74.07 78.32 76 49,207

810 811

870 866

54

61

57,408

92

92.3 71.5

146

162

°CDB °CDB kg kg mm Hz / V

168.3

970 974

58

65

43

49

67

73

79

74

54

59

65

C18 C19 C20 C21 C22 1,722 1,813 1,854 1,902 1,959 7 567 595 624 658 692 3.04 2.97 2.89 2.83 4.21 4.2 4.1 4.08 2,540x2,285 2,540x2,285x14,685 x13,785 12,700 13,040 13,580 13,910 871 82.3

86.61

61

35

High efficiency fin and tube type with integral subcooler 65,610 82,012 82,014 98,414 106,616 114,817 123,018 715 93.5 93.7 94.3 94.5 94.4 94.6 95.1 95.2 95.3 95.6 95.7 95.9 72.3 72.5 72.2 72.3 72.5 72.6 72.8 72.9 73 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 50 R-134a 182 214 225 291 297 312 328 343 2 3 248 219.1 273 219.1 273 3 / 50 / 400

850 88.5 90.7 37

93.5

39

41

123,021 96.2 73.3

96.6 73.7

343

220 2515_BOOK_AppliedSystems_2011.indb 220

25/03/2011 08:38


EWAD-C-PS/PL

EWAD-C-

Air cooled chiller, premium efficiency, standard/low sound

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • 11 sizes to cover a range from 821 up to 1,562kW • EER range up to 3.64 • 2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Partial and heat recovery option available • New MicroTech III controller

Standard available • Wye Delta Starter (Y - D) • Double setpoint • Fans thermal relays • Phase monitor • Evaporator victaulic kit • 20mm Evaporator insulation • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock • Emergency stop

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP fans • Fan silent • Low ambient • Power factor 0.9 • Dual pressure relief valve • Suction line shut off valve • A/V meter • Condenser coil guards • Soft starter • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

COOLING ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions

Nom. Method Minimum capacity Cooling Nom.

Unit

kW % kW

820 821

225 3.64 4.44

HeightxWidthxDepth mm

Weight (PS)

Unit Operation weight Weight (PL) Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level (PS) Cooling Nom. Sound pressure level (PS) Cooling Nom. Sound power level (PL) Cooling Nom. Sound pressure level (PL) Cooling Nom. Compressor Type Operation range Water side Cooling Air side Cooling Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

Heat exchanger

249 3.58 4.5

7,530 8,130 7,820 8,420

274 3.56 4.41

7,660 8,700 7,950 8,990

39.22

599 42.53

1,043 46.6

57

65

30

96,199

l/s rpm dBA dBA dBA dBA Min.~Max. Min.~Max.

980 975

2,540x2,285x8,885

kg kg kg kg l l/s kPa

890 890

101 79.5 98.4 76.9

°CDB °CDB kg mm Hz / V

204

202

204

219.1

C11 1,074

C12 1,158

301

Stepless 12.5 330 3.51 4.39

C13 1,279

363 3.52 4.53 4.44 2,540x2,285 2,540x2,285x9,785 x11,085 8,290 8,550 9,390 9,330 9,590 10,380 8,580 8,840 10,380 9,620 9,880 10,670 Single pass shell & tube 1,027 995 51.3 55.31 61.12 61

69

60

C14 1,390

C15 1,474

C16 1,562

396 3.51 4.31

424 3.48 4.33

453 3.45 4.32

2,540x2,285x11,985 9,730 10,720 10,720 11,010

66.41

979 70.30

74.50

73

81

89

High efficiency fin and tube type with integral subcooler 106,888 117,577 128,266 920 101.8 102.3 102.6 102.9 80 80.5 80.4 80.5 98.8 99.9 99.3 99.6 77 77.1 77.2 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 52 R-134a 220 252 2 273 3 / 50 / 400

128,266 103.2 80.8 99.9 77.5

103.5 81.1 100.2 77.8

254

221 2515_BOOK_AppliedSystems_2011.indb 221

25/03/2011 08:38


EWAD-C-PR

EWAD-C-

Air cooled chiller, premium efficiency, reduced sound

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • 11 sizes to cover a range from 809 up to 1,521W • EER range up to 3.7 • 2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator - one pass refrigerant side to minimize pressure drops • Partial and heat recovery option available • New MicroTech III controller

Standard available • Wye Delta Starter (Y - D) • Double setpoint • Fans thermal relays • Phase monitor • Evaporator victaulic kit • 20mm Evaporator insulation • Evaporator electric heater • Electronic expansion device • Discharge line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock • Emergency stop

Options • Total heat recovery • Partial heat recovery • Single pump • Twin pump • High ESP fans • Fan silent • Low ambient • Power factor 0.9 • Dual pressure relief valve • Suction line shut off valve • A/V meter • Condenser coil guards • Soft starter • Blank Cu/Al coils • Cu/Sn coils • Cu/Cu coils • Spring Anti Vibration Mounts

COOLING ONLY Capacity class Cooling capacity Capacity control Power input EER ESEER Dimensions

Nom. Method Minimum capacity Cooling Nom.

Unit

kW % kW

810 809

880 875

960 956

C10 1,053

219 3.7 4.63

244 3.58 4.59

272 3.51 4.54

299 3.52 4.59

HeightxWidthxDepth mm

Weight

Unit Operation weight Water heat exchanger Type Water volume Nominal water flow Cooling Nominal water Cooling pressure drop Air heat exchanger Type Fan Air flow rate Nom. Speed Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Water side Cooling Air side Cooling Refrigerant Type Charge Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

2,540x2,285x8,885

kg kg

Heat exchanger

l l/s kPa

7,820 8,420

38.65

599 41.81

1,043 45.69

56

63

29

73,811

l/s rpm dBA dBA Min.~Max. Min.~Max.

7,950 8,990

92.7 71.2

°CDB °CDB kg mm Hz / V

204

202

204

219.1

C11 1,132 Stepless 12.5 330 3.43 4.5

C13 1,251

364 3.44 4.53 2,540x2,285 2,540x2,285x9,785 x11,085 8,580 8,840 10,380 9,620 9,880 10,670 Single pass shell & tube 1,027 995 50.3 54.11 59.76 59

66

58

High efficiency fin and tube type with integral subcooler 82,012 90,213 715 93.4 93.8 94.1 71.7 72.0 Semi-hermetic single screw compressor -8 ~ 15 -18 ~ 52 R-134a 220 252 2 273 3 / 50 / 400

C14 1,359

C15 1,439

C16 1,521

396 3.43 4.51

425 3.39 4.50

457 3.33 4.45

2,540x2,285x11,985 10,720 11,010

64.95

979 68.7

72.6

70

77

84

98,414 94.4

98,417 94.7 72.3

95 72.6

254

222 2515_BOOK_AppliedSystems_2011.indb 222

25/03/2011 08:38


2515_BOOK_AppliedSystems_2011.indb 223

25/03/2011 08:38


Condensing unit The Daikin condensing units can be used in a wide variety of air conditioning, refrigeration and ventilation applications.

Condensing unit ERAD-E-SS ERAD-E-SL

225 226

For a copy of our latest Price List please call 0845 6419000

224 2515_BOOK_AppliedSystems_2011.indb 224

25/03/2011 08:38


ERAD-E-SS

ERAD170,200E-SS

Air cooled condensing unit, standard efficiency, standard sound

Options (factory mounted) • Total heat recovery • Partial heat recovery • Soft starter • Brine version • Compressor thermal relays • Under / over voltage control • Energy meter • Capacitors cosfi 0.9 • Current limit - display • Speedtrol • Condenser coil guards • Cu-cu condenser coil • Cu-cu sn condenser coil • Alucoat fins coil • High pressure side manometers • Container kit • Rubber anti vibration mount • Spring anti vibration mount • Double pressure relief valve with diverter • Compressor circuit breakers • Fan speed regulation

Strengths • Wide capacity range (121kW - 488kW) • Single refrigerant circuit with single screw compressor • Two sound versions available • Compact design with brazed plate heat exchanger Standard available • Wye delta starter (y - d) • Double setpoint • Fans circuit breakers with thermal overload relays • Phase monitor • Discharge line shut off valve • Suction line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock

COOLING ONLY Indoor units Cooling capacity Capacity control Power input EER Dimensions Weight Air heat exchanger Fan Fan motor Sound power level Sound pressure level Compressor Operation range Refrigerant

Power supply

Nom. Method Minimum capacity Cooling Nom.

kW

Unit HeightxWidthxDepth Unit Operation weight Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Type SST Min-Max Condenser Min-Max Type Charge Circuits Quantity Phase / Frequency / Voltage

mm kg kg

% kW

l/s rpm dBA dBA

120 121

140 144

Hz / V

200 196

220 219

250 252

310 306

370 370

440 435

490 488

Stepless 25 41.8 51.0 2.90 2.83 2,273x1,292x2,165 1,584 1,617 10,922

10,575 91.5 73.5

°C °C kg

170 165

17

20

57.4 65.2 73.7 76.6 92.8 122.0 147.2 160.8 2.87 3.00 2.97 3.28 3.30 3.04 2.96 3.03 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070 1,741 1,936 2,679 1,781 1,981 2,756 High efficiency fin and tube type with integral subcooler 16,383 15,863 21,844 21,150 32,767 31,725 920 92.3 93.0 94.2 94.5 95.2 73.7 73.9 75.1 75.0 75.3 76.0 Semi-hermetic single screw compressor -9~12 -18~48 R-134a 22 27 29 32 45 54 58 1 3~ / 50 / 400

225 2515_BOOK_AppliedSystems_2011.indb 225

25/03/2011 08:38


ERAD-E-SL

ERAD160,190E-SL

Air cooled condensing unit, standard efficiency, low sound

Options (factory mounted) • Total heat recovery • Partial heat recovery • Soft starter • Brine version • Compressor thermal relays • Under / over voltage control • Energy meter • Capacitors cosfi 0.9 • Current limit - display • Speedtrol • Condenser coil guards • Cu-cu condenser coil • Cu-cu sn condenser coil • Alucoat fins coil • High pressure side manometers • Container kit • Rubber anti vibration mount • Spring anti vibration mount • Double pressure relief valve with diverter • Compressor circuit breakers • Fan speed regulation

Strengths • Wide capacity range (116kW - 462kW) • Single refrigerant circuit with single screw compressor • Two sound versions available • Compact design with brazed plate heat exchanger • Low operating sound levels Standard available • Wye delta starter (y - d) • Double setpoint • Fans circuit breakers with thermal overload relays • Phase monitor • Discharge line shut off valve • Suction line shut off valve • Ambient outside temperature sensor and set-point reset • Hour run meter • General fault contactor • Set-point reset, demand limit and alarm from external device • Fans circuit breakers • Main switch interlock

COOLING ONLY Indoor units Cooling capacity Capacity control Power input EER Dimensions Weight Air heat exchanger Fan Fan motor Sound power level Sound pressure level Compressor Operation range Refrigerant

Power supply

Nom. Method Minimum capacity Cooling Nom.

kW

Unit HeightxWidthxDepth Unit Operation weight Type Air flow rate Nom. Speed Cooling Nom. Cooling Nom. Cooling Nom. Type SST Min-Max Condenser Min-Max Type Charge Circuits Quantity Phase / Frequency / Voltage

mm kg kg

% kW

l/s rpm dBA dBA

120 116.0

140 137

Hz / V

190 187

210 209

240 243

300 295

350 352

410 409

460 462

Stepless 25 42.3 52.5 2.74 2.61 2,273x1,292x2,165 1,684 1,717 8,372

8,144 89.0 71.0

°C °C kg

160 159

17

20

57.6 66.3 73.9 78.2 91.5 122 150 167 2.75 2.82 2.83 3.11 3.23 2.88 2.73 2.76 2,273x1,292x3,065 2,273x1,292x3,965 2,223x2,236x3,070 1,841 2,036 2,789 1,881 2,081 2,886 High efficiency fin and tube type with integral subcooler 12,558 12,217 16,744 16,289 25,117 24,433 715 89.8 90.5 91.7 92.0 92.7 71.2 71.4 72.6 72.5 72.8 73.5 Semi-hermetic single screw compressor -9~12 -18~48 R-134a 22 27 29 32 45 54 58 1 3~ / 50 / 400

226 2515_BOOK_AppliedSystems_2011.indb 226

25/03/2011 08:38


2515_BOOK_AppliedSystems_2011.indb 227

25/03/2011 08:38


Water cooled chiller Daikin offers you compact water cooled chiller units which require only very limited space in a machine room. Used for commercial or industrial applications, these chillers generate cold and hot water, which can be used for chilling, heating, or even both at the same time.

Water cooled chiller new

new new new new new

EWWP-KBW1N EWWD-MBYN EWWD-G-SS EWWD-G-XS EWWD-I-SS EWWD-I-XS EWWD-BJYNN EWWQ-AJYNN EWWQ-AJYNN/A EWWD-FZXS

229 231 232 233 234 235 236 237 238 239

For a copy of our latest Price List please call 0845 6419000

228 2515_BOOK_AppliedSystems_2011.indb 228

25/03/2011 08:38


EWWP-KBW1N

EWWP014-035KBW1N

Water cooled chiller

Options (factory mounted) • Chilled water temperature down to - 5°C (OPZH) or -10°C (OPZL)

Strengths • One of the most compact units in the market (60cm x 60cm x 60cm for models 014 to 035) • Daikin scroll compressor • Standard reverse phase protection • Extension possible up to 195kW For single module units • Standard main isolator switch • Basic hydraulic components for KB-series included with the unit as a kit: flow switch, air purge, filter + shut-off valves for both condenser and evaporator

Available inputs/outputs • Input - Remote ON / OFF - Pump contact - Cool/heat selection • Output - Compressor operation - Summary alarm - Pump relay contact

Accessories (kit) • Compressor soundproof material (-3dBA) • Hydraulic module (see page EHMC) • BMS gateway (MODBUS protocol) • Remote user interface Control • Microprocessor control • Water inlet temperature control • Cold water or hot water regulation

HEATING ONLY & COOLING ONLY Capacity class Cooling capacity Nom. Heating capacity Nom. Capacity steps number Power input Cooling Nom. EER Dimensions Unit HeightxWidthxDepth Weight Unit Operation weight Water heat exchanger Type - evaporator Minimum water volume in the system Water flow rate Min. Nom. Max. Water heat exchanger Type - condenser Water flow rate Min. Nom. Max. Sound power level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Evaporator water drain Condenser water inlet/outlet Condenser water drain Power supply Phase / Frequency / Voltage

kW kW

014 13.0 16.6

022 21.5 27.3

028 28.0 35.4

035 32.5 41.2

045 43.0 54.8

055 065 56.0 65.0 71.4 82.7 2 11.80 15.50 17.60 3.64 3.61 3.69 600x600x1,200 300 320 334

mm kg kg

118

1 5.79 7.48 3.71 3.74 600x600x600 155 165

l l/min l/min l/min

62 19 37 75

103 31 62 123

134 40 80 161

155 47 93 186

205 62 123 247

268 80 161 321

311 93 186 373

l/min l/min l/min dBA

24 48 95

39 78 157 64

51 102 203

59 118 237 71

79 157 314

102 205 410

118 237 474 74

kW

3.61 3.60

8.75 3.71 172

67

°CDB °CDB

kg

1.2

1 2 2.5 FBSP 25mm FBSP 25mm

3.1

2 4.6 5.6 FBSP 40mm FBSP 40mm

Hz / V

090 86.0 110

100 99.0 126

110 120 130 112 121 130 143 154 165 4 23.6 27.3 31.0 33.1 35.2 3.64 3.63 3.61 3.66 3.69 1,200x600x1,200 600 620 640 654 668 Brazed plate 205 268 311 123 142 161 173 186 247 284 321 347 373 493 568 642 694 745 Brazed plate 157 181 205 221 237 314 362 410 442 474 629 724 819 883 948 71 75 77 Hermetically sealed scroll compressor -10 (OPZL) ~ 25 20 ~ 55 R-407C Thermostatic expansion valve 4 9.2 10.2 11.2 2 x 2 x FBSP 38mm Field installation 2 x 2 x FBSP 38mm Field installation 3N~ / 50 / 400

145 142 181

155 155 198

39.1 3.63

42.8 3.62

165 168 214

175 177 226

6 46.5 48.6 50.7 3.61 3.64 3.67 1,800x600x1,200 940 960 974 988

920

205 204 407 814

185 186 237

222 444 889

195 195 248 52.8 3.69 1.002

268 311 254 267 280 507 533 559 1,015 1,066 1,118

241 482 963

260 283 307 323 339 355 519 567 614 647 679 711 1,038 1,133 1,229 1,293 1,357 1,422 73 76 78 79

6 13.8

14.8 15.8 3 x 2 x FBSP 38mm

16.8

3 x 2 x FBSP 38mm

229 2515_BOOK_AppliedSystems_2011.indb 229

25/03/2011 08:38


EWWP

Water cooled chiller

EWWP014-035KBW1N

EWWP090-130KBW1N

EWWP145-195KBW1N

SELECTION TABLE

1 MODULE (KB-SERIES)

2 MODULES (KB-SERIES)

3 MODULES (KB-SERIES)

Capacity index

014

022

028

035

045

055

065

090

100

110

120

130

145

155

165

175

185

195

Cooling capacity (kW)

13.0

21.5

28.0

32.5

43.0

56.0

65.0

86.0

99.0

112

121

130

142

155

168

177

186

195

16.6 1 -

27.3 1 -

35.4 1 -

41.2 1 -

54.8 1 1 -

71.4 1 1 -

82.7 1 1 -

110 2 1 -

126 1 1 1 -

143 2 1 -

154 1 1 1 -

165 2 1 -

181 2 1 1

198 1 2 1

214 3 1

226 2 1 1

237 1 2 1

248 3 1

Heating capacity (kW) UNIT + CONTROL (Factory mounted) MODULAR UNITS (Controller available as accessory) CONTROL (kit)

EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N EWWP045KAW1M EWWP055KAW1M EWWP065KAW1M ECB2MUAW ECB3MUAW

For example: for a 121 kW HP system, select: EWWP055KBW1N + EWWP065KBW1N

230 2515_BOOK_AppliedSystems_2011.indb 230

25/03/2011 08:38


EWWD-MBYN

EWWD120MBYN

Water cooled chiller

Strengths • Compact and modular design • DAIKIN stepless single screw compressor • Standard reverse phase protection • VICTAULIC joints • DICN operation as standard within same series • Standard discharge shut-off valve • Standard filter, flow switch Options (factory mounted) • Main isolator switch • Low noise (-5 to -7dB(A)) • Compressor suction stop valve • Ampere & Voltmeter (read-out on switchbox) • Dual pressure relief valve

Accessories • Gateway BACnet RS232 (EKBMSBNA) • Gateway ModBus RS232/RS485 (EKBMSMBA) • Address card screw chillers (EKAC’200A) • Remote controller kit screw chillers Control • Microprocessor control • Water inlet or outlet temperature control • Weekly operating schedule

Available inputs/outputs • Input - ON / OFF - Pump contact - Dual setpoint through analog signal - Floating setpoint • Output - Compressor operation - Summary alarm (per circuit) - Pump relay contact

HEATING ONLY & COOLING ONLY Capacity class Cooling capacity Heating capacity Capacity steps Power input EER COP Dimensions

Nom. Nom. Cooling Heating

Unit

Unit Operation weight Water heat exchanger Water flow rate - evaporator

kW kW % kW kW

Nom. Nom.

HeightxWidth (incl. filter space)xDepth

Weight

Nominal water pressure drop (circuit1/circuit2)

Min. Nom. Max. Cooling

180 240 183 249.0 216 290.0 stepless 30 - 100 45.2 61.6 54.0 72.8 4.05 4.04 4.00 3.98

Power supply

Circuits Quantity Relief device outlet Evaporator water inlet/outlet Evaporator water drain Condenser water inlet/outlet Phase / Frequency / Voltage

360 366 431

440 432 505

69.2 83.4 3.95 3.92

90.5 108.0

107.0 127.0

3.99

3.98

500 498 580 stepless 15 - 100 123.0 146.0 4.05 3.97

520 522 617

540 546 655

131.0 156.0 3.98 3.96

138.0 167.0 3.96 3.92

1,273 1,318 265 525 1,070

1,527 1,588 350 714 1,400

1,623 1,693 400 783 1,600

2,546 2,636 525 1,049 2,100

2,800 2,906 625 1,238 2,500

3,034 3,156 700 1,428 2,800

3,150 3,281 750 1,496 3,000

3,346 3,485 800 1,565 3,200

21 / -

25 / -

26 / -

22 / -

25 / 25

25 / 26

26 / 26

26 / 22

22 / 22

2/23 / -

3/28 / -

7/33 / -

9/31 / -

7/7 33 / 33

7/9 33 / 31

9/9 31 / 31

l

600

890

1,220

1,215

1,275

1,335

l/min l/min l/min kPa

217 435 800

336 654 1,050

450 890 1,230

3/3 3/7 28 / 28 28 / 33 Brazed plate, one per circuit 1,330 895 1,055 Shell and tube 520 670 790 981 1,309 1,545 1,370 2,100 2,290

900 1,781 2,470

970 1,871 2,600

1,040 1,962 2,730

30 / 38

38 / 38

mm kg kg l/min l/min l/min kPa

25 / dBA °CDB °CDB kg

30 / -

87

93

2,000x2,681(3,254)x930

38 / -

30 / 30

94

93 Semi-hermetic single screw compressor -10 ~ 20 20 ~ 60 20 ~ 50 R-134a 37 38 70 72 Thermostatic Electronic expansion Electronic expansion valve expansion valve. Thermostatic valve expansion valve

20 ~ 50 18

4.04

1,018x2,681(3,254)x930

35

Thermostatic expansion valve

Piping connections

280 273.0 327.0

28.7 34.5 4.29 4.26 1,018x2,681(3,051) x930 1,000 1,032 175 353 700

Heat exchanger Filter kPa Total kPa

Type Minimum water volume in the system Water heat exchanger Type - condenser Water flow rate Min. Nom. Max. Nominal water Heating pressure drop (circuit1/circuit2) Sound power level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control

120 123 147

1 1x1"

20 ~ 60 74

75

76

Electronic expansion valve 2

2 x 1"

76.1mm

96

3 x 1"

4 x 1"

88.9mm Field installation 88.9mm 3~ / 50 / 400

76.1mm Hz / V

231 2515_BOOK_AppliedSystems_2011.indb 231

25/03/2011 08:38


EWWD-G-SS

Water cooled chiller, standard efficiency, standard sound EWWD-G-SS

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 165.5–555.7kW • EER range up to 4 • 1-2 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return Standard available • Suction stop valve • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Glycol application • Total heat recovery • Partial heat recovery • Power factor 0.9 • A/V meter • Low noise • Soft starter • Cu/Ni heat exchanger Accessories • Communication cards (EKAC200J –EKACBC – EKACLON) • Remote user interface (EKRUPCK) • Buffer tanks (EKBT500N - EKBTC10N - EKBT500C - EKBTC500C) • Daikin serial sequencing panel (EKDSSP) • Modem (EKMODEM – EKG SMOD) • Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB)

HEATING ONLY & COOLING ONLY Indoor units Cooling capacity Heating capacity Capacity control Power input

Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.

EER COP ESEER Dimensions Weight

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type - evaporator Water volume Nominal water Cooling Total pressure drop Water heat exchanger Type - condenser Water flow rate Nom. Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW kW

170 166 204

210 201 247

260 253 310

300 280 343

320 334 410

380 372 456

420 403 494

460 448 552

500 494 610

600 556 674

129 161 3.83 3.79 5.1

150 177 3.70 3.81 4.93

Stepless % kW kW

mm kg kg l kPa

l/s kPa

25 42.2 52.7 3.93 3.87 5.00

50.6 64.9 63.5 80.8 3.97 3.90 3.89 3.84 5.04 4.95 1,860x920x3,435 1,410 1,503 1,480 1,650

1,393 1,470 60

56

48

69

4.72

123 43

84.3 106 3.96 3.88 5.28

93 117 4.00 3.91 5.33

2,687 2,697 2,840 2,850 Single pass shell and tube 118 113 53

9.95

12.02

15.19

16.98

39

41

63

77

dBA dBA

64

63

Single pass shell and tube 19.99 22.22 40

50

12.5 101 115 127 144 3.97 3.89 3.89 3.84 5.29 5.19 1,880x860x4,305 2,702 2,757 2,860

2,762 2,970

173 72

168 54

24.08 41

87.7 69.7

68

26.90

29.77

33.73

57

60

75

90.2 71.7

°CDB °CDB kg

75.3 89.2 3.72

55

Semi-hermetic single screw compressor -8~15 20~55 R-134a 110 50 Electronic expansion valve

1

55

110

2

88.9mm

114.3mm

139.7mm

5" 3 / 50 / 400

Hz / V

232 2515_BOOK_AppliedSystems_2011.indb 232

25/03/2011 08:38


EWWD-G-XS

EWWD-G-XS

Water cooled chiller, high efficiency, standard sound

Strengths • High efficiency • EER range up to 4.73 • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 186.4–603.9kW • 1-2 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return Standard available • Suction stop valve • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Glycol application • Total heat recovery (EWWD190500DJYNN/A) • Partial heat recovery • Power factor 0.9 • A/V meter • Low noise • Soft starter • Cu/Ni heat exchanger Accessories • Communication cards (EKAC200J - EKACBAC - EKACLON) • Remote user interface (EKRUPCK) • Buffer tanks (EKBT500N - EKBTC10N - EKBT500C - EKBTC500C) • Daikin Serial Sequencing panel (EKDSSP) • Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB)

HEATING ONLY & COOLING ONLY Indoor units Cooling capacity Heating capacity Capacity control Power input

Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.

EER COP ESEER Dimensions Weight

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type - evaporator Water volume Nominal water Cooling Total pressure drop Water heat exchanger Type - condenser Water flow rate Nom. Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW kW

190 186 220

230 223 264

280 277 326

320 307 354

380 366 434

400 408 482

460 444 524

500 496 585

550 541 638

650 604 712

87.2 110 4.68

95.1 120 4.67

105 132 4.73 4.38 4.42 6.24 6.23 6.31 1,880x860x4,305 2,800 2,945 2,955 2,975 3,020 3,280 3,290 3,315 Single pass shell and tube 170 285

115 144 4.72 4.43 6.30

137 162 4.39 4.40 5.85

Stepless % kW kW

mm kg kg l kPa

l/s kPa dBA dBA

25 39.6 50.1 4.70 4.38 5.97 1,650 1,800 125

12.5

48.1 59.4 60.6 74.5 4.64 4.66 4.35 4.38 5.9 5.92 1,860x920x3,435 1,665 1,680 1,810 1,820 120

110

25

35

44

10.78

12.95

16.07

18.08

17

20

25

28

79.2 99.9 4.62 4.34 6.15

30

24

Single pass shell and tube 21.27 23.66

1 114.3mm

280

39

46

57

25.76

28.71

31.34

35.40

16

15

19

90.9 71.7 Semi-hermetic single screw compressor -8~15 20~55 R-134a 110 105 Electronic expansion valve

55

2,990 3,340

28

17

88.2 69.7

°CDB °CDB kg

71.4 83.7 4.30 4.23 5.46

100 2

139.7mm

168.3mm

5" 3 / 50 / 400

Hz / V

233 2515_BOOK_AppliedSystems_2011.indb 233

25/03/2011 08:38


EWWD-I-SS

Water cooled chiller, standard efficiency, standard sound

EWWD-I-SS

Strengths • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 333-1,510kW • EER range up to 4.66 • 1-2-3 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops

Options (factory mounted) • Glycol application • Total heat recovery • Partial heat recovery • Power factor 0.9 • Suction stop valve • A/V meter • Soft starter • Cu / Ni heat exchanger • Dual pressure relief valve

Standard available • Main switch • Gauges • Electronic expansion valve

Accessories • Communication cards (EKAC200J – EKACBAC – EKACLON) • Remote user interface (EKRUPCK) • Buffer tanks (EKBT500N - EKBTC10N - EKBT500C - EKBTC500C) • Daikin serial sequencing panel (EKDSSP) • Modem (EKMODEM – EKG SMOD) • Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB)

HEATING ONLY & COOLING ONLY Indoor units Cooling capacity Heating capacity Capacity control Power input

Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.

EER COP ESEER Dimensions Weight

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type - evaporator Water volume Nominal water Cooling Heat pressure drop exchanger Water heat exchanger Type - condenser Water flow rate Nom. Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW kW % kW kW

mm kg kg l kPa

l/s kPa dBA dBA

340 333 388.4

900 950 C10 C12 C13 C14 C15 C16 C17 910 986 1,027 1,155 1,204 1,274 1,346 1,401 1,455 1,072 1,161 1,217 1,363 1,427 1,507 1,227 1,661 1,730 Stepless 25 12.5 8.3 71.5 85.8 101 120 141 156 171 186 200 218 237 254 268 282 298 317 335 87.4 104 122 143 174 191 208 225 243 262 282 309 326 344 363 383 401 4.66 4.59 4.56 4.47 4.53 4.52 4.57 4.55 4.51 4.33 4.54 4.50 4.51 4.43 4.35 4.44 4.42 4.41 4.35 4.36 4.42 4.41 4.43 4.32 4.41 4.38 3.38 4.34 4.31 5.06 4.96 4.93 4.86 5.54 5.75 5.56 5.7 5.47 5.61 5.36 5.51 5.56 5.54 5.55 5.45 1,821x1,430x3,398 2,113x1,350x4,361 2,323x2,135x4,426 2,150 2,160 2,179 2,224 3,909 3,927 3,945 3,971 3,996 4,080 4,092 6,079 6,097 6,136 6,174 6,192 6,210 2,380 2,396 2,410 2,457 4,217 4,228 4,243 4,262 4,288 4,369 4,386 6,628 6,646 6,670 6,699 6,717 6,735 Single pass shell and tube 193 183 172 271 263 256 248 241 233 472 504 489 472 37

400 394 460

50

460 460 538

550 538 630

54

650 640 757

62

700 705 832

55

44

850 844 993

58

53

66

51

62

56

47

58

62

66

C18 1,510 1,790

353 420 4.28 4.26 5.27 6,228 6,761

71

Single pass shell and tube 19.33 22.92 26.80 31.44 37.31 41.14 45.53 49.21 53.03 57.52 60.39 67.32 70.33 74.34 78.55 82.08 85.52 89.01 26

28

93.7 75.2

96.6 76.2

54

52

30

26

25

96.7 78.2

28

96.9 77.8

97.3 78.2

108

106 168.3mm

°CDB °CDB

1 kg

800 782 919

51

50

26

23

24

25

97.8 98.9 99.8 100.4 100.8 101.2 78.7 79.8 80.7 80.4 80.8 81.2 Semi-hermetic single screw compressor -8~15 20~55 R-134a Electronic expansion valve 2 104 100 156 155 154

24

23 103.0 83.0

3 153 152 219.1mm

151

150

5" 3 / 50 / 400

Hz / V

234 2515_BOOK_AppliedSystems_2011.indb 234

25/03/2011 08:38


EWWD-I-XS

Water cooled chiller, high efficiency, standard sound

EWWD-I-XS

Strengths • High efficiency • All models are PED pressure vessel approved • Stepless single-screw compressor • Optimised for use with R-134a • Cooling range: 362-1,134 kW • EER range: 4.72-5.1 • 1 or 2 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator – one pass refrigerant side to minimize pressure drops Standard available • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Glycol application • Partial heat recovery • Power factor 0.9 • Suction stop valve • A/V meter • Soft starter • Cu / Ni heat exchanger • Dual pressure relief valve Accessories • Communication cards (EKAC200J – EKACBAC – EKACLON) • Remote user interface (EKRUPCK) • Buffer tanks (EKBT500N - EKBTC10N - EKBT500C - EKBTC500C) • Daikin serial sequencing panel (EKDSSP) • Plant visor (EKPV 2J) • Modem (EKMODEM – EKG SMOD) • Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB)

HEATING ONLY & COOLING ONLY Indoor units Cooling capacity Heating capacity Capacity control Power input

Nom. Nom. Method Minimum capacity Cooling Nom. Heating Nom.

EER COP ESEER Dimensions Weight

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type - evaporator Water volume Nominal water Cooling Heat pressure drop exchanger Water heat exchanger Type - condenser Water flow rate Nom. Water flow rate 2 Nom. Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW kW % kW kW

mm kg kg l kPa

360 362 410.9

71 85.9 5.10 4.78 5.34 2,594 2,998

440 433 493

500 506 577

600 573 660

25 85.4 100 103 121 5.07 5.06 4.79 4.77 5.27 5.22 1,883x1,430x4,081 2,667 2,704 3,078 3,116

326

317

64

48

121 143 4.75 4.62 5.11

308 54

l/s l/min kPa

20.69

24.77

48

47

dBA dBA

93.7 75.20

96.6 76.2

90

87

750 720 823

28.95

33.16

51

°CDB °CDB

156 189 5.10 4.80 6.31

48

47

48

85

180

177

168.3mm

174

C10 976 1,126

C11 1,038 1,203

C12 1,134 1,313

199 240 4.9 4.69 5.9

219 263

240 285 4.73

4.57 6.05

5,097 5,729

4.61 5.67 5,132 5,741 504

50

72

46

52

23.31 28

28.07 28.07

27.10 33

32.82 32.82

47

96.9 97.3 97.8 77.8 78.2 78.7 Semi-hermetic single screw compressor -8~15 20~55 R-134a Electronic expansion valve

1 kg

950 933 1,069

170 206 5.08 4.81 6.01

Single pass shell and tube 20.58 20.44 24.75 20.58 24.98 24.75

66 96.7 78.2

850 866 990

12.5 185 223 5.05 4.79 6.14 2,245x1,350x4,769 4,964 4,997 5,049 5,073 5,582 5,615 5,671 5,695 Single pass shell and tube 539 528 141 172 5.09 4.78 6.13

68

-

800 795 908 Stepless

50

65

98.9 79.8

99.8 80.7

2 172 219.1mm

170

5" 3 / 50 / 400

Hz / V

235 2515_BOOK_AppliedSystems_2011.indb 235

25/03/2011 08:38


EWWD-BJYNN

EWWDC11BJYNN

Water cooled chiller, high efficiency, flooded evaporator

Strengths • All models are PED pressure vessel approved • 1 and 2 stepless single-screw compressors • Optimised for use with R-134a • Cooling range: 369–1050kW • Super high efficiency: EER up to 5.84 • Very high EER values at part loads condition • Flooded evaporator • Expansion valve with liquid level control Standard available • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Glycol application • Suction stop valve • A / V meter • Soft starter • Cu / Ni heat exchanger Accessories • Communication cards (EKAC200J – EKACBAC – EKACLON) • Remote user interface (EKRUPCK) • Buffer tanks (EKBT500N - EKBTC10N - EKBT500C - EKBTC500C) • Daikin serial sequencing panel (EKDSSP) • Modem (EKMODEM – EKG SMOD) • Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB)

COOLING ONLY Capacity class Cooling capacity Capacity steps Power input EER ESEER Dimensions Weight

Nom. Cooling

Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Type - evaporator Minimum water volume in the system Water flow rate Min. Nom. Max. Nominal water Cooling Heat pressure drop exchanger Water heat exchanger Minimum water volume in the system - condenser Water flow rate Min. Nom. Max. Nominal water Heating pressure drop Water heat exchanger - heat recovery condenser Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water drain Power supply Phase / Frequency / Voltage

380 369

750 734

l l/min l/min l/min kPa

78 565 1,058 1,788

129 142 5.65 5.71 7.16 7.23 2,300x4,145x1,743 5,546 5,636 5,911 6,045 Flooded shell and tube 184 932 1,216 2,104 2,339 2,946 3,846

35

43

37

51

37

l l/min l/min l/min kPa

83 665 1,244 2,103

111 948 1,499 2,998

133 1,086 1,752 3,435

181 1,478 2,474 4,675

199 1,703 2,746 5,386

35

25

26

28

26

kW % kW

mm kg kg

Type dBA

460 550 445 521 stepless 25 - 100 65 77.9 90 5.68 5.71 5.79 6.44 6.47 6.56 2,250x3,625x1,551 2,250x3,860x1,551 3,089 3,370 3,603 3,250 3,588 3,870 107 615 1,276 1,945

134 776 1,494 2,455

900 895 Stepless 12.5 - 100 155 5.77 7.32 2,300x4,145x1,808 6,007 6,460 210

C10 976

167 180 5.81 5.83 7.37 7.40 2,300x4,145x1,910 6,448 6,598 6,972 7,163 281 1,382 2,798 4,370

1,209 2,566 3,825 45

C11 1,050

302 1,632 3,010 5,162

41

34

1,904 3,010 6,020

1,924 3,277 6,085

263 2,146 3,526 6,786

25

29

27

82

82.5

83

230

274

290

243

Shell and tube 78

79

80

130

165

180

°CDB °CDB kg

850 816

Hz / V

81 81.5 Semi-hermetic single screw compressor -8 ~ 15 21 ~ 50 R-134a 200 215 Electronic expansion valve 1 1/2" gas 3~ / 50 / 400

236 2515_BOOK_AppliedSystems_2011.indb 236

25/03/2011 08:38


EWWQ-AJYNN

EWWQC19-C20AJYNN

Water cooled chiller, standard efficiency

Strengths • Cooling range: 388-2,093kW • EER range up to 4.64 • ESEER up to 5.37 • 1 or 2 stepless single-screw compressors • 1 or 2 truly independent refrigerant circuits • Optimised for use with R-410A • Shell and tube heat exchanger • Standard electronic expansion valve • Compact design • Partial heat recovery available • All models are PED pressure vessel approved Standard available • Glycol application • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Partial heat recovery • Power factor 0.9 • A/V meter • Soft starter • Pressure relief valve • Suction stop valve Accessories • Communication cards (EKAC200J – EKACBAC –EKACLON) • Modem (EKMODEM – EKG SMOD) • Remote user interface (EKRUPCK) • Converter RS485 to RS232 (EKCON) or to USB (EKCONUSB)

COOLING ONLY Capacity class Cooling capacity Capacity control

Nom. Method Minimum capacity

kW

480 474.13

750 742.14

800 812.53

850 880.09

106.27 130.44 147.86 169.73 4.46 4.40 4.41 4.37 4.98 4.97 4.72 1,846x1,266 1,846x1,065x3,431 2,000x1,226x3,440 x3,561 1,933 1,967 2,283 2,332 2,407 2,135 2,169 2,543 2,628 2,777

12.5 stepless 12.5 - 100 175.22 4.64 5.37 2,170x1,350 x4,902 3,921 4,422

25 stepless 25 - 100 206.4 4.26 4.60 1,846x1,266 x3,561 2,427 2,795

% %

Capacity steps Power input EER ESEER Dimensions

400 387.96

Cooling

Nom.

Unit

HeightxWidthxDepth mm

Unit Operation weight Water heat exchanger Type Water heat exchanger Water flow rate Nom. - evaporator Nominal water Cooling pressure drop Water heat exchanger Water flow rate Nom. - condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Condenser Cooling Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Refrigerant circuit 2 Charge Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW

Weight

kg kg l/min Heat kPa exchanger l/min kPa dBA dBA Min.~Max. Min.~Max.

600 574.36

650 651.45

25 stepless 25 - 100 87.37 4.44 4.95

1,111.8 1,359 1,646.4 1,867.2 2,124.6 2,328.6 2,519.4

C13 C14 C15 C16 C17 C18 C19 C20 1,210.09 1,281.09 1,352.09 1,488.14 1,620.34 1,783.43 1,928.13 2,092.73 12.5 stepless 12.5 - 100 261.72 279.05 296.39 339.95 375.37 408.72 441.58 475.47 4.62 4.59 4.56 4.38 4.32 4.36 4.37 4.40 5.36 5.35 5.29 4.93 4.82 4.89 4.87 2,455x1,350x4,835

2,547x1,350x4,844

2,547x1,350x4,809

4,529 4,536 4,607 4,988 4,999 5,053 5,204 5,289 5,186 5,200 5,280 5,602 5,615 5,670 5,881 5,970 3,468 3,671.4 3,875.4 4,260

4,636 5,105.4 5,519.4 5,990.4

1,372.2 1,675.2 2,034.6 2,307.6 2,632.2 2,851.2 3,136.2 3,132.6 3,445.2 3,676.8 3,794.4 4,249.2 4,504.2 4,759.2 5,277.6 5,760.6 6,328.8 6,841.2 7,413.6 60.15 64.35 67.91 66.02 16.46 64.44 20.43 66.55 67.64 25.92 70.09 100.2 101.2 82.2 83.0

102.3 83.9

1 80

90 -

168.3mm 5" Hz / V

C10 C11 C12 980.45 1.028.15 1,077.43 stepless 12.5 25 stepless Stepless 12.5 - 100 25 - 100 194.02 212.97 245.47 236.90 4.59 4.60 4.19 4.55 5.36 5.34 4.53 5.33 1,846x1,266 2,379x1,350 2,170x1,350x4,902 x3,561 x4,912 3,949 3,988 2,457 4,344 4,463 4,496 2,812 4,780 Shell and tube 2,554.2 2,809.8 2,943 3,088.2

49.43 64.65 45.04 47.92 54.74 53.80 50.22 63.54 59.07 57.23 70.01 45.37 50.28 55.40 59.86 69.74 89.42 98.78 122.57

°CDB °CDB

kg kg

900 891.19

73.40

69.77 16.52 19.31 16.93 17.08 15.02

101.5 104.7 102.3 104.7 105.1 103.2 104.7 105.2 106.5 83.2 84.0 84.9 85.2 85.6 86 86.5 86.9 Semi-hermetic single screw compressor -4~10 25~45 R-410A Electronic expansion valve 2 1 2 1 100 85 100 85 100 95 100 85 85 95 100 219.1mm 6" 5" 6" 5" 6" 5" 3~ / 50 / 400

105.8 106.2 106.6 107.1 107.5 86.2 86.6 87 87.5 87.9

2 130 130 273mm 6"

237 2515_BOOK_AppliedSystems_2011.indb 237

25/03/2011 08:38


EWWQ-AJYNN/A

EWWQC19-C22AJYNN/A

Water cooled chiller, high efficiency

Strengths • Cooling range: 431-2,196kW • EER range up to 5.09 • ESEER up to 5.98 • 1 or 2 stepless single-screw compressors • 1 or 2 truly independent refrigerant circuits • Optimised for use with R-410A • Shell and tube heat exchanger • Standard electronic expansion valve • Compact design • Partial heat recovery available • All models are PED pressure vessel approved Standard available • Glycol application • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Partial heat recovery • Power factor 0.9 • A/V meter • Soft starter • Pressure relief valve • Suction stop valve Accessories • Communication cards (EKAC200J – EKACBAC –EKACLON) • Converter RS485 to RS232 • Converter RS485 to USB • Modem (EKMODEM – EKG SMOD) • Remote user interface (EKRUPCK) • Daikin serial sequencing panel (EKDSSP)

COOLING ONLY Capacity class Cooling capacity Capacity steps Power input EER ESEER Dimensions

Nom.

kW %

Cooling

Nom.

Unit

HeightxWidthxDepth mm

Unit Operation weight Water heat exchanger Type Water heat exchanger Water flow rate Nom. - evaporator Nominal water Cooling pressure drop Water heat exchanger Type - condenser Water flow rate Nom. Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Condenser Cooling Refrigerant Type Control Circuits Quantity Refrigerant circuit Charge Refrigerant circuit 2 Charge Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW

Weight

kg kg l/min Heat kPa exchanger

Min.~Max. Min.~Max.

440 431

550 527

650 635

750 740

800 818

950 993

86.67 104.72 128.28 145.95 4.97 5.03 5.09 5.07 5.58 5.61 5.69 5.67 2,001x1,218 2,000x1,211x3,987 x3,855 2,322 2,403 2,464 2,738 2,594 2,685 2,745 3,158

162.04 196.57 5.05 5.64 5.39 2,000x1,266 2,001x1,448 x3,854 x3,891 2,407 2,427 2,815 3,056

1,197

1,463.4 1,813.2

2,058

2,272.8

2,760

C11 C12 C13 C14 C15 C16 C18 1,139 1,182 1,297 1,397 1,479 1,605 1,769 stepless stepless 12.5 - 100 25 - 100 232.06 233.11 257.54 274.77 291.86 321.48 356.36 4.91 5.07 5.04 5.08 5.07 4.99 4.96 5.28 5.87 5.88 5.98 5.93 5.67 5.71 2,001x1,448 2,453x1,350x4,985 2,547x1,350x4,844 x3,891 2,457 4,831 4,873 4,919 4,969 5,117 3,086 5,479 5,512 5,546 5,606 5,794 5,843 Shell and tube 2,944.2 3,164.4 3,286.2 3,606.0 3,882.6 4,108.8 4,459.8 4,957.0

55.77

68.81

64.27

57.46

53.85

53.69

stepless 25 - 100

71.54

C10 1,059 stepless 12.5 - 100 209.49 5.06 5.89 2,453x1,350 x4,985 4,775 5,431

68.89

64.23

55.13

67.85

75.14

4,708.8

4,986

49.20

46.82

l/min kPa

1,457.4 1,778.4

2,199

2,496.6

2,760

3,350.4 3,573.6

Shell and tube 3,861 3,986.4 4,380

50.16

39.75

42.38

46.94

59.79

64.73

40.10

83.56

dBA dBA

100.9 82.2

101.7 83.0

102.6 102.7 83.9

102 83.2

102.9 84.0

110

130

105.2 103.8 105.6 106.1 106.5 85.6 84.9 86 86.5 86.9 Semi-hermetic single screw compressor -4~10 25~45 R-410A Electronic expansion valve 2 1 120 130 120 120 120 273mm 5" 3~ / 50 / 400

°CDB °CDB

1 kg kg

95 219.1mm

Hz / V

47.93

48.17

70.1

89.12

C19 1,901

C20 2,061

C22 2,196

390.31 425.94 460.72 4.87 4.84 4.77 5.48 5.50 5.38 2,547x1,350x4,809 5,388 6,110

5,408 6,118

5,414 6,124

5,283

5,727

6,103.8

91.3

113.04 126.77

5,425.2 5,985.6 6,454.8 7,005.6 7,485.6 44.26

61.21

60.50

105.8 86.2

106.2 86.6

106.6 87

79.00 107.1 87.5

107.5 87.9

2 130 130

238 2515_BOOK_AppliedSystems_2011.indb 238

25/03/2011 08:38


EWWD-FZXS

EWWD640-C10FZXS

Water cooled chiller with centrifugal compressor

Standard available • Inverter compressor starter • Evaporator victaulic kit • Evaporator water side design pressure 10 bar • 20 mm evaporator insulation • Condenser victaulic kit • Condenser water side design 16 bar • Electronic expansion device • Hour run meter • General fault contactor

Strengths • Oil free centrifugal compressor (with magnetic bearings) • Integrated VFD to reach outstanding partial load efficiencies (ESEER up to 9.60), resulting in great energy savings • Reduced maintenance thanks to the elimination of oil • Low sound level (sound pressure at 1m around 80 dB(A)) • Extensive options list • Easy integration with control systems (BMS, Sequencing Panels)

COOLING ONLY Indoor units Cooling capacity Capacity control Power input

Min. Max. Method Cooling Cooling

EER ESEER Dimensions Weight

Min. Max.

HeightxWidthxDepth Unit Unit Operation weight Water heat Type exchanger Nominal water Cooling Heat evaporator exchanger pressure drop Water heat Type exchanger Water flow rate Nom. condenser Nominal water Cooling pressure drop Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Condenser water inlet/outlet Power supply Phase / Frequency / Voltage

kW kW

320 114 317

430 128 429

kW kW

21.6 65.9

27.7 85.7

mm kg kg

5.40 8.60 1,823x1,276x3,254 2,360 2,416 2,520 2,634

kPa

30

31

l/s kPa

18.3

24.6

24

25

dBA dBA

89.0 70.9

90.1 72.0

210

190

°CDB °CDB kg

mm mm Hz / V

168.3

520 640 172 114 521 635 Variable speed centrifugal compressor 33.1 21.6 104 132 6.00 5.40 9.40 8.80 1,823x1,276x3,419 1,755x1,790x3,441 2,546 3,709 2,812 4,074 Flooded shell and tube (2 passes) 23

18

Flooded shell and tube (2 passes) 29.9 36.7 28

24

91.2 92.4 73.0 73.8 Oil free centrifugal compressor with magnetic bearings 2~15 18~46 R-134a 180 220 Electronic expansion valve 1 219.1

168.3

860 128 856

C10 172 1,048

27.7 171 5.50 8.60 1,748x1,853x3,289 4,095 4,548

33.1 206 5.90 9.60 1,794x1,904x3,401 4,765 5,330

21

11

49.1

59.9

25

29

93.6 75.1

94.6 75.9

300

273 219.1

3~ / 50 / 400

239 2515_BOOK_AppliedSystems_2011.indb 239

25/03/2011 08:38


Condenserless chiller Daikin offers you flexible and compact chillers with remote condenser, which can be used to satisfy applications with special requirements in the field of available space, sound level or extreme operating conditions. In these exceptional cases, remote condenser solutions can be preferred over standard air cooled or water cooled solutions.

Water cooled condenserless chiller new new

EWLP-KBW1N EWLD-MBYN EWLD-G-SS EWLD-I-SS

241 242 243 244

For a copy of our latest Price List please call 0845 6419000

240 2515_BOOK_AppliedSystems_2011.indb 240

25/03/2011 08:38


EWLP-KBW1N

EWLP014KBW1N

Water cooled condenserless chiller

Strengths • One of the most compact units in the market (60cm x 60cm x 60cm for models 012 to 030) • Daikin scroll compressor • Standard main isolator switch • Basic hydraulic components : included as a kit with the unit: flow switch, air purge, filter + shut-off valves • Standard reverse phase protection Options (factory mounted) • Chilled water temperature down to - 5°C (ZH) or -10°C (ZL)

Control • Microprocessor control • Water inlet temperature control Available inputs/outputs • Input - Remote ON / OFF - Pump contact • Output - Compressor operation - Summary alarm - Pump relay contact

Accessories (kit) • Compressor soundproof material (-3dBA). • Hydraulic module (see also EHMC) • BMS gateway (MODBUS) • Remote user interface

COOLING ONLY Indoor units Cooling capacity Power input EER Dimensions Weight Water heat exchanger - evaporator

Sound power level Compressor Operation range Refrigerant

Piping connections Power supply

Nom. Cooling

Nom.

Unit HeightxWidthxDepth Unit Minimum water volume in the system Water flow rate Min. Nom. Max. Model Quantity Type Cooling Nom. Type Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Type Control Circuits Quantity Evaporator water inlet/outlet Evaporator water drain Phase / Frequency / Voltage

kW kW mm kg l l/min l/min l/min

dBA

012 12.1 4.2 2.88

020 20.0 6.6 3.03

108 62 17 35 69

141 103 29 57 115

026 26.8 8.5 3.15

030 31.2 10.1 3.09

040 40.0 13.4 2.99

147 134 38 77 153

151 155 45 89 179 1 Brazed plate 71 Hermetically sealed scroll compressor -10~20 25~60 R-407C Thermostatic expansion valve

252 205 57 115 229

055 53.7 17.8 3.02 600x600x1,200 265 268 77 154 307

600x600x600

64

°CDB °CDB

1 FBSP 25mm

67

065 62.4 20.3 3.07 274 311 89 179 358

74

2 FBSP 40mm Field installation 3N~ / 50 / 400

Hz / V

241 2515_BOOK_AppliedSystems_2011.indb 241

25/03/2011 08:38


EWLD-MBYN

EWLD120MBYN

Water cooled condenserless chiller

Control • Microprocessor control • Water inlet temperature control • Weekly operation schedule

Strengths • Daikin stepless single screw compressor • Compact and modular design • Standard phase sequence controller • VICTAULIC joints • DICN operation as standard within same series • Standard discharge shut-off valve • Standard flow switch • Standard filter • Ampere and Voltmeter (read-out on switchbox) • Dual pressure relief valve

Available inputs/outputs • Input - ON / OFF - Pump contact - Dual setpoint through analog signal - Floating set point • Output - Compressor operation - Summary alarm - Fan-condenser relay contacts - Pump relay contact

Accessories (kit) • BMS gateway (MODBUS / J-BUS / BACNET protocol) • Remote user interface

COOLING ONLY Capacity class Cooling capacity Capacity steps Power input EER Dimensions Weight

Nom. Cooling

Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Minimum water volume in the system - evaporator Water flow rate Min. Nom. Max. Nominal water Cooling Heat pressure drop exchanger (circuit 1) Filter Total Nominal water Cooling Heat pressure drop exchanger (circuit 2) Filter Total Model 1 Quantity Type Model 2 Quantity Type Type Sound power level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Control

kW % kW mm kg kg l l/min l/min l/min kPa kPa kPa kPa

120 116

170 240 170 235 stepless 30 - 100 49.8 66.5 3.41 3.53 1,018x2,681x930 1,110 1,342 1,130 1,369 830 1,150 265 350 487 674 1,070 1,400

32.0 3.63 891 907 570 175 333 700

Circuits Quantity Evaporator water inlet/outlet

Power supply

Evaporator water drain Phase / Frequency / Voltage

77.9 3.40

99.6 3.41

116 3.49

1,428 1,462 1,300 400 760 1,600

2,220 2,260 830 525 975 2,100

2,452 2,497 990 625 1,161 2,500

480 470 stepless 15 - 100 133 3.53 2,000x2,681x930 2,684 2,738 1,150 700 1,347 2,800

500 500

540 530

144 3.47

156 3.40

2,770 2,831 1,220 750 1,434 3,000

2,856 2,924 1,295 800 1,520 3,200

25

26

22

25

26

22

3 28

6 32

8 30

3 28

7 33

9 31

-

25

26

22

1

3 28 2

7 33

9 31

AC250Q-NP96

87

AC250Q-NP128 -

93

AC250Q-NP162

1 AC250Q-NP96

1 AC250Q-NP128 Brazed plate, one per circuit

94

93 Semi-hermetic single screw compressor -10 ~ 20 25 ~ 62 25 ~ 55 R-134a Thermostatic Thermostatic expansion Electronic expansion valve expansion valve valve Electronic expansion valve

25 ~ 55

Thermostatic expansion valve

Piping connections

400 405

2 23

AC120EQ-NP156

°CDB °CDB

340 340

21

kPa kPa

dBA

260 265

1 3" OD victaulic coupling

2 AC250Q-NP128 -

1 AC250EQ-NP128 1 AC250EQ-NP162

2 AC250EQ-NP162 -

96

25 ~ 62

Electronic expansion valve 2

3" victaulic coupling Field installation 3~ / 50 / 400

Hz / V

242 2515_BOOK_AppliedSystems_2011.indb 242

25/03/2011 08:38


EWLD-G-SS

Water cooled condenserless chiller, standard efficiency, standard sound EWLD-G-SS

Strengths • Cooling range: 161-526kW • EER range: 3.48-3.70 • Stepless single-screw compressor • Optimised for use with R-134a • 1-2 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return • All models are PED pressure vessel approved Standard available • Main switch • Suction stop valve • Gauges • Electronic expansion valve

Options (factory mounted) • Glycol application • Partial heat recovery • Power factor 0.9 • A/V meter • Low noise • Soft starter • Liquid receiver Accessories • Communication cards (EKAC200J – EKACBAC –EKACLON) • Converter RS485 to RS232 or to USB • Modem (EKMODEM – EKG SMOD) • Bacnet gateway (EKBMSBNJ) • Remote user interface (EKRUPCK) • Daikin serial sequencing panel (EKDSSP) • Buffer tanks (EKBT500N – EKBTC10N – EKBT500C – EKBTC10C)

COOLING ONLY Indoor units Cooling capacity Capacity steps Power input EER Dimensions Weight

Nom. Cooling

Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Minimum water volume in the system - evaporator Water flow rate Min. Nom. Max. Nominal water Cooling Heat pressure drop exchanger Model Quantity Type Type Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW mm kg kg l l/min l/min l/min kPa

160 161

190 240 189 244 stepless 25 - 100 54.3 65.9 3.48 3.70 1,860x1,000x3,700

45.4 3.54 1,280 1,337

280 270

320 316

74.6 3.62 1,398 1,516

1,151 230.20 460.39 649.15

1,354 270.90 541.81 763.95

1,749 349.74 699.47 986.26

1,938 387.58 775.16 1,092.97

48

69

43

53

360 352

380 420 381 428 stepless 12.5 - 100 90.6 99.7 108.6 120 3.48 3.53 3.51 3.57 1,942x1,100x4,400 2,442 2,446 2,501 2,560 1,130 1,262 1,365 1,535 452.22 504.83 546.25 613.90 904.44 1,009.65 1,092.50 1,227.81 1,275.27 1,423.61 1,540.42 1,731.21 64

63

72

480 476

550 526

131.5 3.62

148 3.55 2,506

2,670 1,704 681.84 1,363.69 1,922.80 54

1,884 753.80 1,507.60 2,125.71 68

1 EV19270055

EV27270066

EV27270077 EV27270088 Shell and tube - direct expansion

88 69.7

dBA dBA

EV32270088

EV32270099

90.5 71.7 Semi-hermetic single screw compressor -8~15 25~60 R-134a

°CDB °CDB 5

kg

10 Electronic expansion valve

1

2

88.9

114.3 3~ / 50 / 400

Hz / V

139.7

243 2515_BOOK_AppliedSystems_2011.indb 243

25/03/2011 08:38


EWLD-I-SS

EWLD-

Water cooled condenserless chiller, standard efficiency, standard sound

Strengths • Cooling range: 328-1,422kW • EER range: 3.51-3.91 • Stepless single-screw compressor • Optimised for use with R-134a • 1 or 2 truly independent refrigerant circuits • Standard electronic expansion valve • DX shell and tube evaporator – one pass refrigerant side for easy oil circulation and return • All models are PED pressure vessel approved Standard available • Main switch • Gauges • Electronic expansion valve

Options (factory mounted) • Glycol application • Total heat recovery • Partial heat recovery • Power factor 0.9 • A/V meter • Soft starter • Liquid receiver Accessories • Communication cards (EKAC200J – EKACBAC –EKACLON) • Converter RS485 to RS232 • Converter RS485 to USB • Modem (EKMODEM – EKG SMOD) • Bacnet gateway (EKBMSBNJ) • Remote user interface (EKRUPCK) • Sequencing panel (EKCSCII) • Buffer tanks (EKBT500N – EKBTC10N – EKBT500C – EKBTC10C) • Plant visor (EKPV 2J)

COOLING ONLY Indoor units Cooling capacity Capacity control Power input EER Dimensions Weight

Nom. Method Minimum capacity Cooling Nom.

Unit HeightxWidthxDepth Unit Operation weight Water heat exchanger Water flow rate Nom. - evaporator Nominal water Cooling Total pressure drop Type Sound power level Cooling Nom. Sound pressure level Cooling Nom. Compressor Type Operation range Evaporator Cooling Min.~Max. Condenser Cooling Min.~Max. Refrigerant Type Charge Control Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage

kW % kW mm kg kg l/min kPa

dBA dBA

320 328

400 391

420 428

500 504

600 596

650 657

750 730

800 788

850 850

900 950 919 966 Stepless

C10 C11 C12 C13 C14 C15 C16 C17 1,033 1,078 1,125 1,188 1,267 1,319 1,370 1,422

25 12.5 8.3 83.8 100 116 137 165 181 198 214 231 252 271 279 296 312 329 347 366 386 405 3.91 3.9 3.7 3.67 3.61 3.63 3.69 3.67 3.65 3.56 3.59 3.64 3.60 3.61 3.65 3.60 3.55 3.51 1,899x1,464x3,114 2,325x1,464x4,391 2,415x2,135x4,426 1,861 1,869 1,884 3,331 3,339 3,347 3,356 3,364 3,412 5,146 5,167 5,188 5,208 2,054 2,052 2,056 3,602 3,603 3,604 3,605 3,645 5,667 5,671 5,677 5,680 940.2 1,120.8 1,227.0 1,444.8 1,708.8 1,883.4 2,092.8 2,259.0 2,436.6 2,634.6 2,769.0 2,961.0 3,090.0 3,225.0 3,405.6 3,631.8 3,781.2 3,927.6 4,076.4 34 93.7 75.2

47 96.6 76.2

54

49

96.7 78.2

96.9 77.8

39 97.3 78.2

°CDB °CDB kg 1

52

47

168.3mm Hz / V

45

52

46

49

Single pass shell and tube 97.8 98.9 99.8 100.4 100.8 101.2 78.7 79.8 80.7 80.4 80.8 81.2 Semi-hermetic single screw compressor -8~15 25~60 R-134a 5 Electronic expansion valve 2

41 103 83

51

55

59

100.4 100.8 101.2 80.4 80.8 81.2

63 103 83

3 219.1mm

3~ / 50 / 400

244 2515_BOOK_AppliedSystems_2011.indb 244

25/03/2011 08:38


D.I.C.N.

Daikin Integrated Chiller Network

Applicable series: • EWAQ080-260DAYN (R-410A) • EWYQ080-250DAYN (R-410A) • EWWD120-540MBYN (R-134a) • EWLD120-540MBYN (R-134a)

Daikin chillers can be equipped with DICN which allows the simultaneous operation of up to 4 chillers as if they were a single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable operation of the chiller plant. This function enables a Daikin 2MW chiller plant to be operated via a single controller. Please note that DICN is only possible within the same series.

245 2515_BOOK_AppliedSystems_2011.indb 245

25/03/2011 08:38


Hydraulic Module

EHMC

Hydraulic module

EHMC10-15-30AV1010

mH2O 55 50 45

• • • • • •

3 models available 100 l tank for all sizes Freeze up protection High static pump (option) Standard drain kit (for indoor use) Standard dual pressure ports (before & behind the pump)

40 35

LEGENDS 30

Pump characteristics 1. EHMC30AV1080 2. EHMC10AV1080 & EHMC15AV1080 3. EHMC30AV1010 4. EHMC10AV1010 & EHMC15AV1010

25 20 15

Hydraulic module + filter pressures losses 5. EHMC15/30AV1010 & EHMC15/30AV1080 6. EHMC10AV1010 & EHMC10AV1080

10 5 0

0 20 40 60 80 100 120 140 160 180 200 220 240 260 WF (l/min)

Water flow

HYDRAULIC MODULE 10

EHMC-AV Nominal flow Nominal static height Nominal input Dimensions (HxWxD) Machine weight Sound power Sound pressure Power supply Operation range Piping connections

1010

Water side Air side Water inlet/outlet Drain connection

l/min mH2O W mm kg dBA dBA V1 °C °CDB

15 1080

1010

62 17 630

1010

88 34 1,050

15 650

101

102

1,284x635x688 99

30 1080 27 1,070

10 1,070

104

105

1,284x635x688

63 52

27 2,090 1,284x635x688

63 52

111 63 52

1~/230V/50Hz -10°C ~ 55°C -10°C ~ 43°C 2" BSPF 1/2"

1" BSPF

1080 187

2-1/2" BSPF

BUFFER TANK Description

Volume

Dimensions

Unit weight

Buffer tank with cabinet

200l

1,284x637x754

86.5

EKBT500N

Buffer tank

500l

710x1,670

70

EKBTC10N

Buffer tank

1,000l

860x2,020

100

EKBT500C

Buffer tank with cabinet

500l

1,200x1,200x1,950

160

EKBTC10C

Buffer tank with cabinet

1,000l

1,200x1,450x1,950

185

MODEL EKBT

246 2515_BOOK_AppliedSystems_2011.indb 246

25/03/2011 08:38


2515_BOOK_AppliedSystems_2011.indb 247

25/03/2011 08:38


Fan coil units Fan coil units are a highly efficient means of turning a water chiller, heat pump or hot water boiler into an efficient, quiet air conditioning system.

These units are an effective solution to provide a comfortable environment for both commercial and residential applications. Daikin offers a wide range of fan coil units for both concealed and exposed applications.

3 models are available in flexible application. The only moving part in the units is the fan, making them ideal for use in offices, hotels and at home. The goal is to obtain the right solution, both technically and aesthetically.

1. Fan coil units

Controllers

249

2. Floor standing unit

FWV-DT/DF

250

3. Flexi type units

FWL-DT/DF FWM-DT/DF FWD-AT/AF

251 252 253

4. Wall mounted unit

FWT-BT

254

5. Concealed ceiling units

FWB-BT

255

6. Cassette units new

new

FWC-BT/BF FWF-BT/BF

256 257

For a copy of our latest Price List please call 0845 6419000

248 FanCoilSubContents.indd 248

29/03/2011 18:52


Fan coil unit Controllers

The fan coil units can be operated by different controllers according to the model.

ECFWMB6

FWEC1AA/FWEC2AA/FWEC3AA

Electronic controller FWEC1AA • Control of on-off valves for two or four pipes systems • Control of auxiliary heating element • Cooling/heating switching in the following modes: local or remote manual (centralised), automatic (depending on water temperature (optional) or air temperature) • Possibility, by means of clean contacts, of remote centralised cooling/heating switching and external activation • Temperature sensor kit (accessory FWTSKAA) • Economy function (setpoint correction by 2.5°C and forcing of the fan to run at minimum available speed) • Composed by: - lc display - keyboard • On board and wall mounted installation

EPIMSA6/EPIA6

Electromechanical built-in controller ECFWMB6 • Fan speed selector • Manual cooling/heating changeover • ON / OFF valves can also be controlled with ECFWMB6 Master / slave interface EPIMSA6 • Available as an additional interface, which is required for units with a current greater than 1.12A • Optional for remote control of up to 4 fan coil units • Up to 3 Master / Slave interfaces can be connected in parallel, enabling control over up to 12 fan coil units

FWEC2AA same as FWEC1AA with following additional functions: 1) Humidity management: - display of relative humidity - dehumidification function (cooling mode) Manual activation 2) Serial communication interface (RS485 bus) - possibility to set up a masterslave system up to 247 slave units, in which one of the controls plays the role of master and manages all the other slave units (modbus protocol) FWEC3AA same as FWEC2AA with following additional functions: 1) Back light

Power interface EPIA6 • Available as an additional interface, which is required for units with a current greater than 1.12A • Required for connection of ECFWER6 to FWD12-18 • Can be used as an alternative for Master / Slave interface

2) Proportional valve control (two voltage outputs for the proportional valves) 3) Voltage contact 0-10V (same as 2) 4) Time clock and weekly schedule (on / off or setpoint air) 5) Integration in BMS (already included in the FWEC2AA version) 6) Two digital outputs (voltage free) to manage electric heaters with the weekly schedule

MERCA

Standard wired remote controller • • • • • • • • • •

Fan speed Sleep function Swing Temperature setting Operating mode LCD display ON / OFF switch Real time clock Timer active Timer ON / OFF

SRC-COB/HPB

WRC-COB/HPB

Simplified wired remote controller for cooling only & heat pump

Wireless controller for cooling only & heat pump

• • • • • • • •

• • • • • • • • • •

Temperature display Temperature setting Timer switch setting ON / OFF switch Fan speed Operating mode Swing 'Sleep' function

LCD display Temperature setting Operating mode Timer switch setting Turbo mode Swing 'Sleep' function Real time clock ON / OF switch Fan speed

249 2515_BOOK_FanCoilUnits_2011.indb 249

21/03/2011 19:45


FWV-DT/DF

Floor standing unit

FWV01, 02DT/DF

FWEC1, 2, 3A

ECFWMB6

• Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor • Quick fixing system for wall mounted installation • Pre-assembled 3-way/4-port ON/OFF valves are available • Valve packages are insulated, no extra drain pan required • Valve packages contain balancing valves and sensor pocket • Fast-on connections for electrical options: no tools needed • Quick removal of washable filter • Electric heater: no relay up to 2kW capacity • Electronic controller with water probe, available in standard, advanced and advanced plus version

Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow

Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit

High High High High HeightxWidthxDepth

Unit Water volume Water volume

Cooling Heating Water pressure drop Cooling Heating Fan Type Air flow rate High Sound power level High Piping connections Drain OD Water connections Std. heat exchanger Power supply Phase / Frequency / Voltage Current input High

kW kW kW kW W mm

01 1.54 1.20 2.14

02 2.09 1.51 2.57

37 53 564x774x226

03 2.93 2.11 3.81 56 564x984 x226

2-PIPE 04 4.33 3.15 5.63 -

98 564x1,194x226

kg l l

19 0.5

20 0.7

25 1

30

l/h l/h kPa kPa

265 265

359 359

504 504 11

745 745 12

m³/h dBA mm inch Hz / V A

06 4.77 3.65 6.36

31 1.4

08 6.71 4.91 7.83

10 8.02 5.96 10.03

137 175 564x1,404x251 41 2.1

01 1.46 1.14

02 1.90 1.51

03 2.87 2.07

1.90 2.10 37 53 564x774x226

3.08 56

20 0.5

820 1,154 1,343 820 1,154 1,343 13 14 12 19 9 11 9 10 9 16 Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 45 50 47 52 56 58 64 16 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76

21 0.7 0.2

251 196

564x984 x226 26 1 0.3

4-PIPE 04 4.33 3.15 5.05

06 4.67 3.57

5.30 98 564x1,194x226 32

33

08 6.64 4.85

10 7.88 5.85

7.91 9.30 137 175 564x1,404x251

1.4

44 2.1

0.4

0.6

327 182

494 745 803 1,142 1,355 286 396 465 694 816 13 11 12 14 12 19 7 8 5 10 8 9 Centrifugal multi-blade, double suction 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 16 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76

250 2515_BOOK_FanCoilUnits_2011.indb 250

21/03/2011 19:45


FWL-DT/DF Flexi type unit

FWL03DT/DF

FWL03DT/DF

ECFWMB6

FWEC1, 2, 3A

• Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor • Quick fixing system for wall or ceiling mounted installation • Pre-assembled 3-way/4-port ON/OFF valves are available • Valve packages are insulated, no extra drain pan required • Valve packages contain balancing valves and sensor pocket • Fast-on connections for electrical options: no tools needed • Quick removal of washable filter • Electric heater: no relay up to 2kW capacity • Electronic controller with water probe, available in standard, advanced and advanced plus version

Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Water pressure drop Fan Sound power level Water connections Power supply Current input

Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit

High High High High HeightxWidthxDepth

kW kW kW kW W mm

01 1.54 1.20 2.14

02 2.09 1.51 2.57

37 53 564x774x226

03 2.93 2.11 3.81 56 564x984 x226

2-PIPE 04 4.33 3.15 5.63 -

98 564x1,194x226

Unit Water volume Water volume

kg l l

20 0.5

21 0.7

27 1

32

Cooling Heating Cooling Heating Type Air flow rate High High Std. heat exchanger Phase / Frequency / Voltage High

l/h l/h kPa kPa

265 265

359 359

504 504 11

745 745 12

m³/h dBA inch Hz / V A

06 4.77 3.65 6.36

33 1.4

08 6.71 4.91 7.83

10 8.02 5.96 10.03

137 175 564x1,404x251 44 2.1

01 1.46 1.14

02 1.90 1.51

03 2.87 2.07

1.90 2.10 37 53 564x774x226

3.08 56

21 0.5

820 1,154 1,343 820 1,154 1,343 13 14 12 19 9 11 9 10 9 16 Centrifugal multi-blade, double suction 319 344 442 706 785 1,011 1,393 45 50 47 52 56 58 64 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76

22 0.7 0.2

251 196

564x984 x226 28 1 0.3

4-PIPE 04 4.33 3.15 5.05

06 4.67 3.57

5.30 98 564x1,194x226 34

35

08 6.64 4.85

10 7.88 5.85

7.91 9.30 137 175 564x1,404x251

1.4

46 2.1

0.4

0.6

327 182

494 745 803 1,142 1,355 286 396 465 694 816 13 11 12 14 12 19 7 8 5 10 8 9 Centrifugal multi-blade, double suction 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 1/2 3/4 1 / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76

251 2515_BOOK_FanCoilUnits_2011.indb 251

21/03/2011 19:45


FWM-DT/DF Flexi type unit

FWM01, 02DT/DF

FWEC1, 2, 3A

FWM01, 02DT/DF

• Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor • Quick fixing system for wall or ceiling mounted installation • Pre-assembled 3-way/4-port ON/OFF valves are available • Valve packages are insulated, no extra drain pan required • Valve packages contain balancing valves and sensor pocket • Fast-on connections for electrical options: no tools needed • Quick removal of washable filter • Electric heater: no relay up to 2kW capacity • Electronic controller with water probe, available in standard, advanced and advanced plus version

Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Water pressure drop Fan Sound power level Piping connections Water connections Power supply Current input

Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit Unit Water volume Water volume

High High High High HeightxWidthxDepth

Cooling Heating Cooling Heating Type Air flow rate High High Drain OD Std. heat exchanger Phase / Frequency / Voltage High

kW kW kW kW W mm kg l l

01 1.54 1.20 2.14

02 2.09 1.51 2.57

37 53 535x584x224 14 15 0.5 0.7

03 2.93 2.11 3.81 56 535x794x224 19 1

2-PIPE 04 4.33 3.15 5.63 -

06 4.77 3.65 6.36

98 535x1,004x224 23 1.4

08 6.71 4.91 7.83

10 8.02 5.96 10.03

137 175 535x1,214x249 32 2.1

01 1.46 1.14

265 265

359 359

9

11

m³/h dBA mm inch Hz / V A

319 45

344 50

0.17

0.24

13

504 504 11

745 745 12

820 1,154 1,343 820 1,154 1,343 14 12 19 9 10 9 16 Centrifugal multi-blade, double suction 442 706 785 1,011 1,393 47 52 56 58 64 17 1/2 3/4 1~ / 50 / 230 0.25 0.44 0.43 0.60 0.76

03 2.87 2.07

1.90 2.10 37 53 535x584x224 15 16 0.5 0.7

3.08 56 535x794x224 20 1

0.2

0.3

-

l/h l/h kPa kPa

02 1.90 1.51

251 196

4-PIPE 04 4.33 3.15 5.05

06 4.67 3.57

08 6.64 4.85

10 7.88 5.85

5.30 98 535x1,004x224 25 1.4

7.91 9.30 137 175 535x1,214x249 34 2.1

0.4

0.6

327 182

494 745 803 1,142 1,355 286 396 465 694 816 13 11 12 14 12 19 7 8 5 10 8 9 Centrifugal multi-blade, double suction 307 327 431 690 763 998 1,362 45 50 47 52 56 58 64 17 1/2 3/4 1~ / 50 / 230 0.17 0.24 0.25 0.44 0.43 0.60 0.76

252 2515_BOOK_FanCoilUnits_2011.indb 252

21/03/2011 19:45


FWD-AT/AF

Flexi type unit

FWD04AT/AF

FWD04AT/AF

FWEC1,2,3A

• Quick fixing system for wall or ceiling mounted installation • Straight duct connector is mounted to discharge side • Electronic controller with water probe, available in standard, advanced and advanced plus version • The air filter can easily be removed for cleaning

Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow Water pressure drop Fan

Sound power level Piping connections Water connections Power supply Current input

Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit Unit Water volume Water volume

High High High High

kW kW kW kW W HeightxWidthxDepth mm kg l l

Cooling Heating Cooling Heating Type Air flow rate High Available pressure High High Drain OD Std. heat exchanger Phase / Frequency / Voltage High

04 3.90 3.08 4.05

06 6.20 4.65 7.71

234 349 280x754x559 280x964x559 33 41 1.06 1.42

2-PIPE 10 12 8.82 11.90 7.16 9.36 10.79 14.45 443 714 280x1,174x559 352x1,174x718 47 49 65 1.79 2.38 2.5 08 7.80 6.52 9.43

16 16.40 12.80 19.81

18 18.30 14.10 21.92

1,197 352x1,384x718 77 80 4.02 5.03

-

l/h l/h kPa kPa

674 674 17 14

m³/h Pa dBA mm inch Hz / V A

800 66 66

0.95

1,064 1,064

1,339 1,339

1,514 2,056 2,833 3,140 1,514 2,056 2,833 3,140 24 16 26 34 45 20 13 21 28 37 Centrifugal multi-blade, double suction 1,250 1,600 2,200 3,000 58 68 64 97 145 134 69 72 74 78 16 3/4 1 1~ / 50 / 230 1.58 1.97 3.21 5.37

04 3.90 3.08

06 6.20 4.65

4.49 6.62 234 349 280x754x559 280x964x559 35 43 1.06 1.42 0.35

0.47

674 349 17 9

1,064 581

800 63 66

0.95

4-PIPE 10 12 8.82 11.90 7.16 9.36 9.21 15.86 443 714 280x1,174x559 352x1,174x718 50 52 71 1.79 2.38 2.50 08 7.80 6.52

0.59 1,339

1.42

16 16.40 12.80

18 18.30 14.10

21.15 1,197 352x1,384x718 83 86 4.02 5.03 1.72

1,514

2,056 2,833 3,140 808 1,392 1,856 24 16 26 34 45 15 13 12 16 Centrifugal multi-blade, double suction 1,250 1,600 2,200 3,000 53 63 59 92 138 128 69 72 74 78 16 3/4 1 1~ / 50 / 230 1.58 1.97 3.21 5.37

253 2515_BOOK_FanCoilUnits_2011.indb 253

21/03/2011 19:45


FWT-BT

Wall mounted unit

FWT05, 06BT

MERCA

SRC-COB/HPB

WRC-COB/HPB

• • • • • • • • • • •

Wide operating range Easy installation and maintenance 3-speed fan motor Double-intake centrifugal fans Excellent air flow and air distribution Flexibility via interchangeable water connection side High power air flow Insulated with self-extinguishing class 1 heat insulation Removable washable air filter (self-extinguishing class 1) Slim and compact aesthetic design Wireless remote control up to 9m distance, availability of a wired or simplified controller • LED indicator gives run and fault indication

Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Water flow Water pressure drop Fan Sound power level Sound pressure level Piping connections Water connections Power supply Current input

Total capacity High Sensible capacity High 2-Pipe High High Unit HeightxWidthxDepth Unit Operation weight Water volume Cooling Heating Cooling Heating Type Air flow rate High High High Drain OD Std. heat exchanger Phase / Frequency / Voltage High

kW kW kW W mm kg kg l l/h l/h kPa kPa m³/h dBA dBA mm inch Hz / V A

02 2.34 1.74 3.02 24 260x799x198 10 10 0.49 402 402 48.3 42

2-PIPE 04 3.22 2.35 4.10 29

03 2.78 2.03 3.75 25

05 4.54 3.65 6.01 66

260x899x198 12 13 0.57 478 478 64.7 58.6

467

510 53

40

39 16

0.11

554 554 69.3 60.6 Centrifugal-direct driven fan motor 586 55 42

06 5.28 4.33 6.74 69 304x1,062x222 16 17 0.85

781 781 50.3 50.6

908 908 69.3 70.6

1,070 61 49

1,121 64 50 20

1/2 1~ / 50 / 220-240 0.13

0.29

0.30

254 2515_BOOK_FanCoilUnits_2011.indb 254

21/03/2011 19:45


FWB-BT

Concealed ceiling unit

FWB04BT

FWEC1, 2, 3A

• Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor • Compact dimensions, can easily be mounted in a narrow ceiling void 3, 4 or 6 stage row cooling coil • Drain pan to collect the condensate from: heat exchanger and regulating valves • 7-speed electrical motors (with thermal protection on windings) • All 7 speeds pre-wired in the factory in the terminal block of the switch box • The air filter can easily be removed for cleaning

Indoor units Cooling capacity Heating capacity Power input Dimensions Weight Heat exchanger Additional heat exchanger Water flow

Water pressure drop

Fan

Sound power level Sound pressure level Piping connections Water connections Power supply Current input

Total capacity Sensible capacity 2-Pipe 4-Pipe High Unit Unit Operation weight Water volume Water volume

High High High High

kW kW kW kW W HeightxWidthxDepth mm kg kg l l

Cooling Heating Additional heat exchanger Cooling Heating Additional heat exchanger Type Air flow rate High Available pressure High High High Drain OD Std. heat exchanger Add. heat exchanger Phase / Frequency / Voltage High

l/h l/h l/h kPa kPa kPa m³/h Pa dBA dBA mm inch inch Hz / V A

02 2.61 1.88 5.47

23 24 1.1

03 3.14 2.16 6.01 3.14 79 239x1,039x609 24 26 1.5

04 3.49 2.34 6.47

05 5.08 3.6 10.31

26 28 2.2

31 33 1.6

598 567

873 904

0.4 448 480 8 7

539 527 275 14 10 3

2-PIPE 06 5.45 3.87 11.39 5.99 154 239x1,389x609 33 35 2.1

07 6.47 4.4 12.28

08 7.57 5.23 15.05

35 38 3.2

43 45 2.1

09 8.67 5.96 16.85 12.8 294 239x1,739x609 45 48 2.8

0.6

11 8

400 71 56 44.5

0.36

936 1,111 1,299 999 1,077 1,319 526 15 8 14 12 7 10 16 5 Centrifugal - forward blades - directly coupled on fan motor 800 65 59 47.5 16 3/4 3/4 1~ / 50 / 230 0.73

10 10.34 6.9 18.78

48 52 4.2

1.7 1,488 1,479 1,123 21 15 8

1,774 1,647 26 18

1,200 59 69 57.5

1 1.28

255 2515_BOOK_FanCoilUnits_2011.indb 255

21/03/2011 19:45


FWC-BT/BF Round flow cassette

FWC-BT/BF

BRC315D7

BRC7E532/3

• 360° air discharge ensures uniform air flow and temperature distribution • DC Fan motor: Low Power input • Modern stylish decoration panel in white (RAL9010) • Fresh air intake kit available • Comfortable horizontal air discharge ensures draught free operation and prevents ceiling soiling • Possibility to close 1 or 2 flaps for different air flow patterns Examples of air flow patterns possible

• Drain pump standard mounted (lift: 850mm)

850 mm

Indoor units Cooling capacity Heating capacity Power input Dimensions Water pressure drop Fan Sound power level Sound pressure level Piping connections Power supply

2-PIPE Total capacity High 2-Pipe High 4-Pipe High High Unit HeightxWidthxDepth Cooling Heating Type Air flow rate High High High Drain OD Phase / Frequency / Voltage

kW kW kW kW mm kPa

m³/h dBA dBA mm Hz / V

06 6.0 8.0

07 7.0 8.9

4-PIPE 08 8.0 10.6

09 9.0 12.1

29

40

19 19

22 22

06 6.0

07 6.7 8.4 40 25 20

09 8.9

9.7 64

11.0 93

32 27

41 34

-

65

94

7.5 28

29 29

35 35

20 17

30.8 59 44

17.1 43 29

288x840x840

17.7 46 30

08 7.8

288x840x840

Turbo fan 20.6 25.4 49 55 34 39 VP25 (external dia. 32, internal dia. 25) 1~ / 50 / 220-240

Turbo fan 19.9 24.6 47 53 33 39 VP25 (external dia. 32, internal dia. 25) 1~ / 50 / 220-240

29.0 57 43

* Note: grey cells contain preliminary data

256 2515_BOOK_FanCoilUnits_2011.indb 256

21/03/2011 19:45


FWF-BT/BF

4-way blow ceiling mounted cassette

FWF-BT/BF

BRC315D7

BRC7E530/1

• Extremely compact casing (575mm in width and depth) enables unit to fit flush into ceilings and match standard architectural modules, without cutting ceiling tiles • Modern stylish decoration panel in white (RAL9010) • Comfortable horizontal air discharge ensures draught free operation and prevents ceiling soiling

• Possibility to close 1 or 2 flaps for different air flow patterns Examples of air flow patterns possible 2-way blow

4-way blow

3-way blow

• Drain pump standard mounted (lift: 750mm)

Indoor units Cooling capacity Heating capacity Power input Dimensions Water pressure drop Fan Sound power level Sound pressure level Piping connections Power supply

2-PIPE Total capacity High 2-Pipe High 4-Pipe High High Unit HeightxWidthxDepth Cooling Heating Type Air flow rate High High High Drain OD Phase / Frequency / Voltage

kW kW kW kW mm kPa

m³/h dBA dBA mm Hz / V

02 2.0 2.9

03 3.2 4.0

4-PIPE 04 4.2 5.4

05 5.4 6.9

66

66

5 5

18 18

02 2.0

03 2.7 3.8 62 13 5

05 4.5

4.9 86

6.1 117

21 9

33 13

-

89

116

3.9 66

29 29

46 46

5 11

14.9 55 42

7.9 44 27

260x575x575

7.9 44 27

04 3.5

260x575x575

Turbo fan 7.9 11.2 44 50 27 35 VP20 (external dia. 26, internal dia. 20) 1~ / 50 / 220-240

Turbo fan 7.2 10.4 46 52 31 36 VP20 (external dia. 26, internal dia. 20) 1~ / 50 / 220-240

13.9 57 41

* Note: grey cells contain preliminary data

257 2515_BOOK_FanCoilUnits_2011.indb 257

21/03/2011 19:45


Air purifiers Allergens are impurities in the air that can bring on an allergic reaction. In an urban environment, a mixture of these allergens with other impurities present in the air can turn allergens into heavy allergens. These in turn can have increased negative health effects such as aggravated symptoms and the triggering of latent allergies.

Daikin’s latest air purifier model, the MC707, is the result of many years of investment in innovation at the service of the customer’s well-being. These efforts place the MC707 among the best residential air purifiers on the market today. Besides a number of practical features, the MC707 owes its enhanced performance to an advanced 7-layer filtering system, the product of Daikin’s continuous drive for innovation and efficiency.

The unique Flash Streamer technology decomposes chemical substances such as odours and formaldehyde into harmless byproducts. It also promotes a photocatalytic reaction on the surface of the Titanium Apatite Photocatalytic Filter that removes bacteria and viruses. Daikin has already received great praise for its air purifiers. A UK Allergy Certificate and the Daikin TüV Award confirm the efficiency of our units.

Photocatalytic air purifier MC707VM-S

259

For a copy of our latest Price List please call 0845 6419000

258 2515_BOOK_AirPurifier_2011.indb 258

23/03/2011 11:47


Photocatalytic air purifier MC707VM-S

MC707VM-S

Pure air for free and healthy breathing • Stylish design • Improved performance • Unprecedented comfort • Super quiet operation • Easy to maintain • Portable • No installation

Three times purification, a good deed for your health Pollen, dust and pet hair are just some of the potential causes of allergies, asthma and respiratory problems. A Daikin air purifier cleans the air and relieves you of these troubles thanks to a three-part operation: • Allergen removal • Virus and bacteria removal • Odour removal

Flash Streamer unit

Pre-filter (with catechin*) Removes large dust particles and pet hairs.

Bio-Antibody Filter Airborne viruses are captured and removed.

Plasma Ionizer Dust and pollen are positively charged and sent to the Electrostatic Filter.

Flash Streamer High-speed electrons are generated by the Flash Streamer. These electrons powerfully break down odours and formaldehyde.

Deodorising Catalyst Odours are adsorbed and broken down before the air is returned to the room.

Electrostatic Dust Collection Filter (front) Positively charged dust and pollen are adsorbed by the negatively charged filter.

*

polluted air

>

>

>

>

>

PLEATED FILTER

>

>

purified air

Titanium Apatite Photocatalytic Filter (back) Odour, bacteria and viruses are adsorbed and decomposed. * Catechin is a natural anti-bacterial substance derived from tea leaves that kills germs that can attach to these particles.

* The filtering surface of a pleated filter is approximately 1.5 times larger than that of a conventional flat filter.

MC707VM-S Model Power supply Dimensions Colour Weight Mode (50Hz) Power input Sound pressure level Sound power level Air flow rate Dust collecting method Deodorising

Bacteria filtering method Filter

HxWxD

mm Kg kW dB(A) dB(A) m3/h

Method Deodorising performance (%) Regenerate method Dust collection and deodorisation

Form Function Lifetime Bio-Antibody filter Pre-filter

Turbo 0.055 47 62 420

MC707VM-S 1~, 220-240/220-230V, 50/60Hz 533x425x213 Sparkling silver + metallic ocean blue 8.7 H M L 0.023 0.014 0.010 38 31 24 52 40 39 285 180 120 Plasma ionizer (electrostatic dust collection) + Electrostatic dust collection filter Flash Streamer + Titanium apatite photocatalytic filter + Deodorising catalyst 95 The Flash Streamer activates the photocatalytic reaction Bio-Antibody filter + Flash Streamer + Titanium apatite photocatalytic filter Pleated filter Deodorisation + disinfection + dust collection + adjuvant removal 1 filter/1 year New Catechin pre-filter

Silent 0.008 16 31 60

259 2515_BOOK_AirPurifier_2011.indb 259

23/03/2011 11:47


260 2515_BOOK_AirPurifier_2011.indb 260

23/03/2011 11:48


261 2515_BOOK_AirPurifier_2011.indb 261

23/03/2011 11:48


Foreword

Power supply

Daikin UK is a leading supplier of heating, cooling and refrigeration solutions for commercial, residential and industrial applications.

T1 = 3~, 220V, 50Hz V1 = 1~, 220-240V, 50Hz VE = 1~, 220-240V, 50Hz/60Hz V3 = 1~, 230V, 50Hz VM = 1~, 220~240V/220~230V, 50Hz/60Hz W1 = 3N~, 400V, 50Hz Y1 = 3~, 400V, 50Hz

Daikin – the leader in manufacturing quality and customer service Daikin was founded in 1924 in Osaka, Japan. The company we now know as Daikin Industries Ltd (DIL) is the parent company of Daikin Europe N.V. (DENV) which was established in Ostend, Belgium in 1972. Daikin Europe is continuously updating and expanding its manufacturing facilities, to a point where they are now acknowledged as the most advanced in their field in Europe. This is backed by zero defect production, efficient supply chain management and unrivalled research and development support from DIL. These substantial production facilities are underpinned by a network of wholly owned affiliate companies in the UK, France, Germany, Italy, Spain, Portugal, Poland, Greece, Belgium, Holland and Central Europe. There are also numerous independent distributors throughout Europe, Africa and the Middle East.

With more than 50 years experience in the production of heat pumps now manufacturing over a million units a year, Daikin has been at the forefront of the drive for energy efficient heat pump technology. The systems are manufactured entirely ‘in-house’ in Daikin’s state of the art factories – this includes the all important energy efficient inverter driven compressor unit. As one of many wholly owned affiliate companies, Daikin UK is a leading supplier of heating, cooling and refrigeration solutions for commercial, residential and industrial applications. Our product portfolio comprises a wide range of highly energy efficient climate control systems which provides the public and private sectors with the right product for any application and requirement.

• State of the art direct expansion air conditioning

Measuring conditions COOLING ONLY 1) nominal cooling capacities are based on: indoor temperature outdoor temperature refrigerant piping length level difference

27°CDB/19°CWB 35°CDB 7.5m 0m

HEAT PUMP 1) nominal cooling capacities are based on: indoor temperature outdoor temperature refrigerant piping length level difference 2) nominal heating capacities are based on: indoor temperature outdoor temperature refrigerant piping length level difference

27°CDB/19°CWB 35°CDB 7.5m 0m 20°CDB 7°CDB/6°CWB 7.5m 0m

CHILLERS: Air-cooled

• H eat pump residential and light commercial heating, domestic hot water and cooling

cooling only heat pump

Water-cooled

cooling only

• Applied central cooling and heating

Remote condenser

• Medium to low temperature refrigeration

heating only

Remote evaporator

cooling capacity/power input conditions

Fan coil units

cooling heating

evaporator: 12°C/7°C ambient: 35°C evaporator: 12°C/7°C ambient: 35°C condenser: 40°C/45°C ambient: 7°CDB/6°CWB evaporator: 12°C/7°C condenser: 30°C/35°C evaporator: 12°C/7°C condenser: 40°C/45°C evaporator: 12°C/7°C condensing temperature: 45°C / liquid temperature: 40°C suction dew point: 5°C ambient: 35°C superheat: 10°C room temperature: 27°C/19°C entering water temperature: 7°C/12°C room temperature: 20°C water inlet temperature: 50°C (2-pipe) / 70°C (4-pipe)

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring conditions: please refer to the technical databooks). The sound power level is an absolute value indicating the ‘power’ which a sound source generates. For more detailed information please consult our technical databooks.

1 2515ProductCatCover_2011_artwork.indd 2

262 28/03/2011 18:39


Daikin UK Product Catalogue 2011

your comfort. our world.

Head Office Daikin Airconditioning UK Limited The Heights, Brooklands, Weybridge, Surrey KT13 0NY Tel 0845 6419000 Fax 0845 6419009

www.daikin.co.uk Unique solutions for every environment

FSC Carbon Balanced Paper

Visit www.eca.gov.uk/etl and type ‘Daikin’ in the quick search box for details of the latest ECA qualifying Daikin units Daikin units comply with the European regulations that guarantee the safety of the product.

The present catalogue is drawn up by way of information only and does not constitute an offer binding upon Daikin UK. Daikin UK has compiled the content of this catalogue to the best of its knowledge. No express or implied warranty is given particular purpose of its content and the products and services

ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.

Daikin Europe N.V. participates in the Eurovent Certification Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP) and Fan Coil Units (FC); the certified data of certified models are listed in the Eurovent Directory. Multi units are Eurovent certified for combinations up to 2 indoor units. VRV products, Rooftops, FWB-J and FWD-units are not within the scope of the Eurovent Certification Programme.

presented therein. Specifications are subject to change without prior notice. Daikin UK explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this catalogue. All content is copyrighted by Daikin UK.

Unique solutions for every environment www.daikin.co.uk

for the completeness, accuracy, reliability or fitness for

UKEPCEN11-500 / 04.11 / DesignHQ. Copyright 2011 Daikin The present publication supersedes UKEPCEN10-500 Printed in the UK on FSC certified paper from sustainable sources.

Daikin UK is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

Daikin UK Product Catalogue 2011


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.