A7

Page 1

Nitrogen Gas Springs

NITROGEN

www.eoc.de


WW WWW W WW W W WW WW W W W W WW WW W W W W WW W W W W WW WW W W W W W W W W W W W

W

W

W

W

W W

W

W W

W

W W

Singapore

United States

DME: a blend of manufacturing, outsourcing and strategic partners

Belgium

W


The DME offer

Global service & distribution W

W

W W

W

DME, a global company, operating in over 100 countries worldwide. From automobiles and ap-

W

W

W

pliances to milk jugs and toothbrushes, DME technologies and services help the world’s leading

W

companies make your favorite products.

W

Success in today’s global market starts with the best product, at the best price, in the required time frame. To achieve this, DME provides customers with the best blend of manufacturing, outsourcing and strategic partners, managed to be deliv-

W

India

ered right on time anywhere in the world using

ChinaW

contemporary, sophisticated techniques.


DME’s commitment: to be an essential resource to customers around the globe


The DME offer

Always the right support Customers of mold technologies face unprecedented demands for speed, cost reduction and performance. Every day, they are pressed to find new ways to do more with less. They need a provider with the resources to contribute to their success, every step of the way. Almost seven decades ago, DME revolutionized the industry with its innovation in standard mold base. Since then, we have built upon our expertise to develop and offer the industry’s most comprehensive portfolio of injection molding supplies.


Runnerless Solutions

Molds & Components

Surface Finishing


The DME offer

Top quality products - at lower costs We deliver a variety of mold components available in all regional standards. Thousands of high performance, off-the-shelf and engineered solutions let our customers spend more time on valuable cavity work. Along with a comprehensive line of equipment and supplies, we provide the high quality products you need to speed up assembly and simplify operations. Only DME can provide customers with the worldwide resources required to compete in the markets of Injection Molds & Components, Hot and Cold Runner Technologies as well as in Die Set Molds & Components or Surface Finishing Technologies.

Our products: designed to make molds work more efficiently


DME NITROGEN GAS SPRING All DME products are accurately manufactured with equipments of high precision such as CNC, M/C, etc., and have passed several trial tests of over one million strokes under SPM80 condition. DME looks forward to a big contribution to the die set industry by developing the TSP series which is compacter than existing gas springs. Quality Assurance DME gas springs come with a two-year warranty from date of shipping from the warehouse or one million strokes. Every troubleshooting service and (or) exchange of parts during this term is free. Also, should any critical defects arise after the two-year guarantee period, the products shall be replaced free of charge. Maintenance DME gas springs are manufactured based on a simple structure , which requires no repairthroughout their lifetime. DME gas springs that are damaged during operations after use can be easily repaired by simply replacing the damaged parts . In addition, adequate load can be specified by directly adjusting the pressure on site. Fast Delivery In order to ensure fast deliveries and support parts for A/S, DME is equipped with requirements such as procurements of load testing facilities , gas charging facilities and a comprehensiveinventory for all spare parts. We also carry sufficient stock for certain models to minimize lead-timeand to reduce deadlock in production. Models that are out of stock can be delivered within 7 days. However, this lead-time varies according to quantity and location.

• •

Notice Although there is a tap of M6 or M8 on top of the piston rod for assembly and a disassembly, this should not be used to fix the gas springs or for any connecting devices. During the installation, please ensure that there is about 1mm of margin space between the contact surface and the upper part of the piston rods, Also, there is no need for pre - pressure because the initial pressure is strong enough. Any increase of pre-pressure can damage the molds. DME gas springs must be used as is. Do not cut or grind the upper part of the piston rods or grind the lower part of the gas springs, as it is dangerous. Any change on the gas spring can shorten its life and cause a malfunction. When installing the springs, please ensure that the bottom surface of the springs touch the mold to absorb the load of gas spring. However, when assembling with mounts, there should be space between the mount and the bottom surface of the mold. This is to prevent the mold from breaking should heavy load breaks the mount.

22/03/2011


Content

GAS SPRING *MODEL *NAME *PAGE

*TSP SERIES *GAS SPRING *P8~31

*TSM SERIES *GAS SPRING *P32~47

*TSS SERIES *GAS SPRING *P48~57

*TSL SERIES *GAS SPRING *P58~73

*PAN3 *CONTROL PANEL *P74

*PAN6 *CONTROL PANEL *P75

*PSS *MULTI PANEL *P76

*HB10.CB4.CB12 *P77

*COMPACT FITTING *FITTING *P78

*GF FITTING *FITTING *P79

*VF FITTING *FITTING *P80

*CHARGING DATA *FITTING *P81

*ACCUMULATOR *PRESSURE DISPERSION TANK *P82

*HOSE MANUAL *FITTING *P83

*FITTING EXAMPLE I,II *FITTING *P84~85

*DISTRIBUTION BLOCK

TECHNICAL DATA CHANGE E

*REPAIR TOOL *TOOLS *P87

*PIPING CHANGE PROCEDURE

*GAS SPRING *P88

*TECHNICAL DATA *GAS SPRING *P89~90

22/03/2011

*CHARGING *ACCESSARIES *P86

www.eoc.de - 1


Gas Springs

Info

Installation and operation

When installing the DME gas spring, the piston rods of the gas springs must be installed parallel to the operation direction and vertical to the installation ground. Failure to do so will result in the generation of odd load and abrasion of piston rods, bearings, and seals etc., which will reduce the life span of the gas spring. To prevent damage to the gas spring and to maximize its life span, please allow 10% margin to the standard stroke to reduce shock that is caused by the compression of gas. The margin can prevent damage on the gas spring when the piston rod touches the bottom surface and shortening a lifespan due to the impact by maximum gas pressure.

22/03/2011

Warning With gas spring fully charged with high pressure gas, non-compliance with this warning may lead to accidents , product damages , malfunctions , etc . Before using the spring , make sure to fully understand and observe the warning below.

2 - www.eoc.de


Gas Springs

Info

Model

EOC gas springs are available from 500N to 100,000N of initial force and from 10mm to 300mm of stroke. Depending on total length, EOC Normalien gas springs provide a wide range to choose from TSP , TSM , TSS and TSL series, and they are easy to use in small molds. Also, EOC Normalien gas springs are available for self contained type, individually used as an independent gas spring, and fitting system type, multiple gas springs that is connected by pipes to adjust gas pressure simultaneously for each gas spring. Conversion between those two types is possible. Recharging and discharging are simple and pressure can be adjusted easily. The maximum gas pressure for each model can be 150~180 bar.

TOSS GAS SPRING

System types Self-contained type Already charged when shipped, it can be easily used, as it does not need extra space for installation of other parts. It may be discharged and recharged with a maximum charging pressure of 150~180 bar.

22/03/2011

Self-contained type Hoses connect with a few gas springs together and each gas spring can be simultaneously charged and discharged. They are easily handled during operations as the control panel controls pressure for each gas spring. The maximum charging pressure is 150 bar.

www.eoc.de - 3


Gas Spring Technology

Info

Certificate Status

PISTON ROD DUST SEAL

PED

DUST RING

97/23/EC

STOP RING CARTRIDGE

1. SYSTEM As EOC Normalien GAS SPRINGS are produced and controlled by a system of international standard. Quality places as PED , ( European pressurized Module A1 ), ISO (Quality control system) and CE (Product Certificate).

O’ RING GUIDE BUSH CYLINDER

ROD SEAL WEAR RING PISTON

2. Product Line-up EOC Normalien gas springs provide a wide range to choose from 4 kinds of standards (TSP, TSM, TSS and TSL series), and more than 1,700 models are available.

PLUG

O’ RING VALVE

3. Product Assessment EOC Normalien Gas springs are exported to more than 30 countries and plans to expand our market abroad with a solid quality, fast delivery and good service.

TSM, TSS, TSL

PISTON ROD

4. Warranty All EOC Normalien gas springs come with a two-year warranty form date of loading from the warehouse or 0.3 ~ 1 million strokes, depending on model. DUST SEAL DUST RING CYLINDER

STOP RING CARTRIDGE ROD SEAL O’ RING

GUIDE BUSH

VALVE O’ RING

PLUG

22/03/2011

TSP

4 - www.eoc.de


22/03/2011

Application Examples

www.eoc.de - 5


TSP Series

www.eoc.de

22/03/2011

NITROGEN


NITROGEN GAS SPRING

TSP Series

TOSS GAS SPRING

CONTENTS

TSP0170 TSP0320 TSP0350 TSP0500 TSP0750 TSP1000 TSP1500 TSP2400 TSP4200 TSP6600 TSP9500 XTRA HIGH POWER

■ Specification

■ General Specification ● Filling Materials Nitrogen GAs(N2)

● Maximum Stroke Rate Per Minute (Recommended) ~50 to 100 (at 20℃)

● Maximum Filling Pressure ● Piston Rod Speed 150~180 bar (at 20℃) ●Minimum Filling Pressure

0.03~0.8 m/s ● Rod Surface Treatment

TYPE

Stroke (mm)

Cylinder Diameter Φ(mm)

Rod Φ(mm)

Initial Force (N)

End Force (N)

MAX. Charging Pressure

TSP0170 TSP0320 TSP0350 TSP0500 TSP0750

25 bar (at 20℃) ● Operation Temperature -5 to 80℃

Nitrate Coating ● Cylinder Surface Treatment Oxidized Black Coating

● Pressure Increase as per Temperature

TSP1000 TSP1500 TSP2400 TSP4200 TSP6600

±0.3% / ℃

TSP9500

22/03/2011

※ The above specification is subject to change without notice for performance improvement.

www.eoc.de - 7


TSP0170

TSP0170

TSP0170

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP0170

REPAIR KIT

Non-repairable

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 180Bar will be charged.

TSP0170 T SP 0170 (inch)

H

7 0.28 44 10 0.39 50 13 0.51 56 16 0.63 62 20 0.79 70 25 0.98 80 30 1.18 90 35 1.38 100 38 1.50 106 40 1.57 110 45 1.77 120 50 1.97 130 60 2.36 150 63 2.48 156 70 2.76 175 75 2.95 185 80 3.15 195 215 90 3.54 100 3.94 235 125 4.92 285 *= at full stroke

C 37 40 43 46 50 55 60 65 68 70 75 80 90 93 105 110 115 125 135 160

Initial I nitial

1,700

E nd force* 2,500 2,500 2,600 2,600 2,700 2,700 2,700 2,700 2,700 2,700 2,800 2,800 2,800 2,800 2,800 2,800 2,800 2,800 2,800 2,800

Gas vol. (㎤) (㎤)

Weight (k g)

2.2 2.9 3.6 4.4 5.3 6.5 7.7 8.9 9.6 10.1 11.3 12.5 14.9 15.6 17.3 18.5 19.7 22.1 24.5 30.4

0.06 0.06 0.07 0.07 0.08 0.08 0.09 0.10 0.11 0.11 0.12 0.12 0.14 0.14 0.15 0.15 0.16 0.18 0.20 0.22

INCREASING RATIO

(mm) (㎜)

Force (N) F orce(N)

( 180 bar bar // +20 +20 ℃ (180 ℃))

FORCE (N)

Strokee Strok

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP0170

Charging pressure(Bar)

Initial Force(N) 9.5

ex) What comes to the charging pressure of gas spring which demands force 1,000N?

105(Bar)

1,000(N) 9.5

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/10

8 - www.eoc.de


TSP0170 Mounts

TSP0170 Mounts XG0170 MOUNT

XC0170 MOUNT

32

30

2 × Ø7 25

25

Ø45

4 × Ø7

12

Ø45

20.5 21.5

7

9

XP0170 MOUNT

32 2 × Ø7 25

Ø45

10

7

22/03/2011

SHINWEON S&T CO.,LTD.

www.eoc.de - 9


TSP0320

TSP0320

NITROGEN GAS SPRING

STROKE

M6 Charge Port DP5

TSP0320

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP0320

REPAIR KIT

Non-repairable

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 180Bar will be charged.

TSP0320 T SP 0320 (inch)

H

7 0.28 44 10 0.39 50 13 0.51 56 16 0.63 62 20 0.79 70 25 0.98 80 30 1.18 90 35 1.38 100 38 1.50 106 40 1.57 110 45 1.77 120 50 1.97 130 60 2.36 150 63 2.48 156 70 2.76 175 75 2.95 185 80 3.15 195 3.54 215 90 100 3.94 235 125 4.92 285 *= at full stroke

C 37 40 43 46 50 55 60 65 68 70 75 80 90 93 105 110 115 125 135 160

I nitial

3,200

E nd force* 5,000 5,000 5,100 5,200 5,200 5,300 5,300 5,400 5,400 5,400 5,400 5,400 5,500 5,500 5,500 5,500 5,500 5,500 5,500 5,500

Gas vol. (㎤)

Weight (k g)

3.7 4.9 6.2 7.4 9.0 11.1. 13.1 15.2 16.4 17.2 19.3 21.3 25.4 26.6 29.5 31.6 33.6 37.7 41.8 52.0

0.09 0.11 0.11 0.12 0.14 0.15 0.16 0.18 0.18 0.19 0.21 0.22 0.25 0.26 0.28 0.28 0.32 0.33 0.36 0.43

INCREASING RATIO

(㎜)

Force (N) F orce(N)

( 180bar bar // +20 +20 ℃ (180 ℃))

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP0320

Charging pressure(Bar)

Initial Force(N) 17.7

ex) What comes to the charging pressure of gas spring which demands force 2,500N?

141(Bar)

2,500(N) 17.7

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/12

10 - www.eoc.de


TSP0320 Mounts

NITROGEN GAS SPRING XR0320(SR0150) MOUNT

TSP0320 Mounts

XB0320(SB0150) MOUNT

27

5 × Ø7 Ø38 40

28

Ø50

28

4 × Ø7

40

21.5 20 9

XG0320(SG0150) MOUNT

Ø50

4 × Ø7 18

30

34

21.5

9

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/13

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 11


TSP0350

TSP0350

NITROGEN GAS SPRING

STROKE

M6 Maintenance only

2 x M6 DP6

Charge Port M6

TSP0350

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP0350

REPAIR KIT

RCX0350

SELF CONTAINED-S FITTING-SYSTEM-F

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 180Bar will be charged.

TSP0350 T SP 0350 (inch)

H

10 0.39 50 13 0.51 56 16 0.63 62 20 0.79 70 25 0.98 80 30 1.18 90 35 1.38 100 38 1.50 106 40 1.57 110 45 1.77 120 50 1.97 130 60 2.36 150 63 2.48 156 70 2.76 170 75 2.95 180 80 3.15 190 90 3.54 210 100 3.94 230 125 4.92 280 *= at full stroke

C 40 43 46 50 55 60 65 68 70 75 80 90 93 100 105 110 120 130 155

I nitial

3,600

E nd force* 5,000 5,100 5,200 5,200 5,200 5,300 5,300 5,300 5,300 5,300 5,300 5,300 5,300 5,300 5,300 5,300 5,300 5,400 5,400

Gas vol. (㎤)

Weight (k g)

7.2 9.0 10.8 13.3 16.3 19.4 22.4 24.2 25.4 28.5 31.5 37.6 39.5 43.7 46.8 49.8 55.9 62.5 77.2

0.20 0.21 0.21 0.23 0.25 0.26 0.28 0.29 0.29 0.32 0.33 0.37 0.37 0.40 0.41 0.43 0.46 0.49 0.58

INCREASING RATIO

(㎜)

Force (N) F orce(N)

( 180bar bar // +20 +20 ℃ (180 ℃))

FORCE (N)

Strokee Strok

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP0350

Charging pressure(Bar)

Initial Force(N) 20.1

ex) What comes to the charging pressure of gas spring which demands force 3,300N?

164(Bar)

3,300(N) 20.1

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/14

12 - www.eoc.de


TSP0350 Mounts

NITROGEN GAS SPRING XP0350 MOUNT

TSP0350 Mounts XR0350 MOUNT

50 35

50

Ø49.5

4 × Ø7

35

Ø60

4 × Ø7

12 35

9 17

6.5

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/15

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 13


TSP0500

TSP0500

NITROGEN GAS SPRING

STROKE

M6 Maintenance only

2 x M6 DP6

Charge Port M6

TSP0500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP0500

REPAIR KIT

RCX0500

SELF CONTAINED-S FITTING-SYSTEM-F

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

TSP0500 T SP 0500 H

10 0.39 50 13 0.51 56 16 0.63 62 20 0.79 70 25 0.98 80 30 1.18 90 35 1.38 100 38 1.50 106 40 1.57 110 45 1.77 120 50 1.97 130 60 2.36 150 63 2.48 156 70 2.76 170 75 2.95 180 80 3.15 190 90 3.54 210 100 3.94 230 125 4.92 280 *= at full stroke

C 40 43 46 50 55 60 65 68 70 75 80 90 93 100 105 110 120 130 155

I nitial

4,700

E nd force* 6,700 6,800 6,900 7,000 7,000 7,100 7,100 7,100 7,100 7,100 7,200 7,200 7,200 7,200 7,200 7,200 7,200 7,200 7,200

Gas vol. (㎤)

Weight (k g)

10.4 13.1 15.7 19.3 23.7 28.2 32.6 35.3 37.0 41.5 45.9 54.8 57.4 63.6 68.1 72.5 81.4 90.3 112.4

0.26 0.28 0.29 0.31 0.33 0.36 0.38 0.39 0.41 0.43 0.46 0.51 0.52 0.55 0.57 0.60 0.65 0.70 0.82

INCREASING RATIO

(㎜) (inch)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP0500

Charging pressure(Bar)

Initial Force(N) 31.4

ex) What comes to the charging pressure of gas spring which demands force 4,000N?

127(Bar)

4,000(N) 31.4

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/16

14 - www.eoc.de


TSP0500 Mounts

NITROGEN GAS SPRING XP0500(SP0300) MOUNT

TSP0500 Mounts

XR0500(SR0300) MOUNT

55 40

Ø56.5

Ø68

55 40

4 × Ø7

12

4 × Ø7 40

17 6.5

9

XT0500(ST0300) MOUNT

XC0500(SC0300) MOUNT

2 × Ø9

52 40

52

40

59 77 95 53 4 × Ø7

20 M6

17 50.3 9

27.5 20

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/17

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 15


TSP0750

TSP0750

NITROGEN GAS SPRING

STROKE

M6 Maintenance only

2 x M8 DP6

Charge Port M6

TSP0750

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP0750

REPAIR KIT

RCX0750

SELF CONTAINED-S FITTING-SYSTEM-F

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

TSP0750 T SP 0750 H

10 0.39 52 13 0.51 58 16 0.63 64 20 0.79 72 25 0.98 82 30 1.18 92 35 1.38 102 38 1.50 108 40 1.57 112 45 1.77 122 50 1.97 132 60 2.36 152 63 2.48 158 70 2.76 172 75 2.95 182 80 3.15 192 90 3.54 212 100 3.94 232 125 4.92 282 *= at full stroke

C 42 45 48 52 57 62 67 70 72 77 82 92 95 102 107 112 122 132 157

I nitial

7,400

E nd force* 10,600 10,900 11,000 11,100 11,300 11,300 11,400 11,400 11,400 11,500 11,500 11,600 11,600 11,600 11,600 11,600 11,600 11,700 11,700

Gas vol. (㎤)

Weight (k g)

15.9 19.8 23.7 28.9 35.4 41.9 48.4 52.3 55.0 61.5 68.0 81.0 84.9 94.0 100.5 107.0 120.0 133.0 165.6

0.40 0.42 0.44 0.47 0.50 0.53 0.56 0.58 0.59 0.63 0.66 0.72 0.74 0.79 0.82 0.85 0.92 0.98 1.14

INCREASING RATIO

(㎜) (inch)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strokee Strok

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP0750

Charging pressure(Bar)

Initial Force(N) 49.1

ex) What comes to the charging pressure of gas spring which demands force 6,000N?

122(Bar)

6,000(N) 49.1

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/18

16 - www.eoc.de


TSP0750 Mounts

NITROGEN GAS SPRING XP0750(SP0500) MOUNT

TSP0750 Mounts

XR0750(SR0500) MOUNT Ø70.7

70 50

Ø86

70 50

4 × Ø9 4 × Ø9

20

50 22 13

6.5

XT0750(ST0500) MOUNT

XB0750(SB0500) MOUNT

64 50

20

64 50

4 × Ø9 2 × M8

2 × Ø9

22 13 70 50

20 50 70

2 × M10

XC0750(SC0500) MOUNT 2 × Ø9

66 82 100 54

M8

20

60 20 30

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/19

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 17


TSP1000

TSP1000

NITROGEN GAS SPRING

STROKE

M6 Maintenance only

2 x M8 DP6

Charge Port M6

TSP1000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP1000

REPAIR KIT

RCX1000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

TSP1000 T SP 1000 (inch)

H

13 0.51 64 16 0.63 70 20 0.79 78 25 0.98 88 30 1.18 98 35 1.38 108 38 1.50 114 40 1.57 118 45 1.77 128 50 1.97 138 60 2.36 158 63 2.48 164 70 2.76 178 75 2.95 188 198 80 3.15 90 3.54 218 100 3.94 238 125 4.92 288 *= at full stroke

C 51 54 58 63 68 73 76 78 83 88 98 101 108 113 118 128 138 163

I nitial

9,200

E nd force* 13,300 13,600 13,800 14,000 14,200 14,300 14,400 14,400 14,500 14,600 14,600 14,700 14,700 14,700 14,800 14,800 14,900 14,900

Gas vol. (㎤)

Weight (k g)

27.3 32.0 38.3 46.2 54.0 61.9 66.6 69.7 77.6 85.4 101.1 105.8 116.8 124.7 132.5 148.2 163.8 203.2

0.58 0.61 0.64 0.68 0.72 0.76 0.78 0.80 0.84 0.89 0.96 0.98 1.04 1.09 1.12 1.21 1.29 1.49

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP1000

Charging pressure(Bar)

Initial Force(N) 61.5

ex) What comes to the charging pressure of gas spring which demands force 8,500N?

138(Bar)

8,500(N) 61.5

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/20

18 - www.eoc.de


TSP1000 Mounts

NITROGEN GAS SPRING MD MOUNT

TSP1000 Mounts WELDED

MS MOUNT

30 2 × Ø11

76

89 111

54

54 76

4 × Ø11

20

MDB

WELDED

25

MSB

MDA

MSA

MK MOUNT

WELDED

24

XP1000(SP0750) MOUNT

24

56.5

75

4 × Ø9

4 × Ø11 75

68 89

24

17

17

56.5

12.7

12

20

XB1000(SB0750) MOUNT

XT1000(ST0750) MOUNT 70 56.5

20

2 × M8

75

2 × Ø9

70 56.5 22

4 × Ø9

13

56.5

20

2 × M10

XR1000(SR0750) MOUNT Ø80

XC1000(SC0750) MOUNT 2 × Ø9 90 110 130

Ø95 70 22

56.5

4 × Ø9

M8

13

30

20

SHINWEON S&T CO.,LTD.

80

www.shinweon.com TSP/21

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

40

www.eoc.de - 19


TSP1500

TSP1500

NITROGEN GAS SPRING

STROKE

M6 Maintenance only

2 x M8 DP6

Charge Port M6

TSP1500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP1500

REPAIR KIT

RCX1500

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SP 1500 (inch)

H

13 0.51 70 16 0.63 76 20 0.79 84 25 0.98 94 30 1.18 104 35 1.38 114 38 1.50 120 40 1.57 124 45 1.77 134 50 1.97 144 60 2.36 164 63 2.48 170 70 2.76 184 75 2.95 194 80 3.15 204 90 3.54 224 100 3.94 244 125 4.92 294 *= at full stroke

C 57 60 64 69 74 79 82 84 89 94 104 107 114 119 124 134 144 169

I nitial

15,200

E nd force* 20,900 21,400 21,900 22,300 22,600 22,900 23,000 23,000 23,200 23,300 23,500 23,600 23,700 23,800 23,800 23,900 24,000 24,100

Gas vol. (㎤)

Weight (k g)

48.8 56.8 67.4 80.7 93.9 107.2 115.2 120.5 133.7 147.0 173.5 181.5 200.1 213.3 226.3 252.9 279.5 346.0

1.04 1.08 1.13 1.20 1.27 1.34 1.37 1.40 1.47 1.58 1.66 1.71 1.80 1.87 1.93 2.07 2.19 2.53

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP1500

Charging pressure(Bar)

Initial Force(N) 101.7

ex) What comes to the charging pressure of gas spring which demands force 12,000N?

118(Bar)

12,000(N) 101.7

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/22

20 - www.eoc.de


TSP1500 Mounts

NITROGEN GAS SPRING MD MOUNT

TSP1500 Mounts WELDED

MS MOUNT

30 2 × Ø11

85

102 122

64

64 85

4 × Ø11

20

MDB

WELDED

25

MSB

MDA

MSA

MK MOUNT

WELDED

26

XP1500 MOUNT 85 60

26

4 × Ø11

4 × Ø13 85

83 105

24

20

21

60

17

12

30

XB1500 MOUNT

XT1500 MOUNT 90 73.5

20

2 × M8

100

2 × Ø11

90 73.5 27

4 × Ø11

16

73.5

20

2 × M12

XR1500 MOUNT

XC1500 MOUNT Ø85

2 × Ø11 102 123 146

Ø105 85 27

60.1

4 × Ø11

M8

16

30

20

SHINWEON S&T CO.,LTD.

90

www.shinweon.com TSP/23

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

45

www.eoc.de - 21


TSP2400

TSP2400

NITROGEN GAS SPRING

STROKE

M6 Maintenance only

4 x M8 DP6 Charge Port M6

TSP2400

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP2400

REPAIR KIT

RCX2400

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SP 2400 (inch)

H

16 0.63 77 20 0.79 85 25 0.98 95 30 1.18 105 35 1.38 115 38 1.50 121 40 1.57 125 45 1.77 135 50 1.97 145 60 2.36 165 63 2.48 171 70 2.76 185 75 2.95 195 80 3.15 205 90 3.54 225 100 3.94 245 125 4.92 295 *= at full stroke

C 61 65 70 75 80 83 85 90 95 105 108 115 120 125 135 145 170

I nitial

23,800

E nd force* 33,800 34,600 35,300 35,800 36,200 36,400 36,600 36,800 37,000 37,400 37,500 37,600 37,700 37,800 38,000 38,100 38,400

Gas vol. (㎤)

Weight (k g)

86.3 102.4 122.5 142.6 162.7 174.8 182.8 203.0 223.1 263.3 275.4 303.5 323.6 343.8 384.0 424.2 524.8

1.58 1.65 1.73 1.81 1.89 1.94 1.97 2.05 2.13 2.30 2.34 2.47 2.55 2.63 2.79 2.95 3.37

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP2400

Charging pressure(Bar)

Initial Force(N) 159.0

ex) What comes to the charging pressure of gas spring which demands force 20,000N?

126(Bar)

20,000(N) 159.0

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/24

22 - www.eoc.de


TSP2400 Mounts

NITROGEN GAS SPRING MD MOUNT

TSP2400 Mounts WELDED

MS MOUNT

38 2 × Ø13

102

120 152

76

76 102

4 × Ø13

20

MDB

WELDED

25

MSB

MDA

MSA

MK MOUNT 26

WELDED

XP2400(SP1500) MOUNT

26

73.5

4 × Ø11

100

95 117

73.5

24

23

23

100

19

12

32

XB2400(SB1500) MOUNT

XT2400(ST1500) MOUNT 90 73.5

20

90 73.5 29

4 × M8

4 × Ø11

100

M20 THRU

4 × Ø11

16

73.5

28.3

XR2400(SR1500) MOUNT Ø104

XC2400(SC1500) MOUNT 2 × Ø11 115 137 160

Ø122 85 29

73.5

4 × Ø11

M10

16

30

20

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/25

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

52.5 105

www.eoc.de - 23


TSP4200

TSP4200

NITROGEN GAS SPRING

STROKE

M8 Maintenance only

4 x M8 DP12 Charge Port G1/8

TSP4200

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP4200

REPAIR KIT

RCX4200

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SP 4200 (inch)

H

16 0.63 90 20 0.79 98 25 0.98 108 30 1.18 118 35 1.38 128 38 1.50 134 40 1.57 138 45 1.77 148 50 1.97 158 60 2.36 178 63 2.48 184 70 2.76 198 75 2.95 208 80 3.15 218 90 3.54 238 100 3.94 258 125 4.92 308 *= at full stroke

C 74 78 83 88 93 96 98 103 108 118 121 128 133 138 148 158 183

I nitial

42,200

E nd force* 60,600 62,300 63,800 65,000 65,900 66,400 66,600 67,200 67,700 68,500 68,700 69,100 69,400 69,600 70,000 70,300 70,900

Gas vol. (㎤)

Weight (k g)

150.5 177.8 212.0 246.2 280.3 300.8 314.5 348.7 382.8 451.2 471.7 519.5 553.6 587.8 656.1 724.5 895.3

3.21 3.32 3.46 3.60 3.75 3.82 3.88 4.02 4.16 4.44 4.52 4.72 4.86 5.00 5.27 5.56 6.25

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP4200

Charging pressure(Bar)

Initial Force(N) 282.6

ex) What comes to the charging pressure of gas spring which demands force 35,000N?

124(Bar)

35,000(N) 282.6

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/26

24 - www.eoc.de


TSP4200 Mounts

NITROGEN GAS SPRING MD MOUNT

TSP4200 Mounts WELDED

MS MOUNT

38 2 × Ø13

127

146 178

98

98 127

4 × Ø13

20

MDB

WELDED

25

MSB

MDA

MSA

MK MOUNT

WELDED

26

XP4200(SP3000) MOUNT 120 92

26

120

115 137

92

24

22

23

4 × Ø13.5

19

12

32

XB4200(SB3000) MOUNT

XT4200(ST3000) MOUNT 110 92

20

110 92 33

4 × Ø13.5

4 × M8

120

M20 THRU

4 × Ø13.5

18

92

42.4

XR4200(SR3000) MOUNT Ø130

XC4200(SC3000) MOUNT 2 × Ø13 145 170 195

Ø150

102.5 33

92

4 × Ø13.5

M12

18

30

20

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/27

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

62.5 125

www.eoc.de - 25


TSP6600

TSP6600

NITROGEN GAS SPRING

STROKE

M8 Maintenance only

4 x M10 DP12 Charge Port G1/8

TSP6600

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP6600

REPAIR KIT

RCX6600

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

TSP6600 T SP 6600 (inch)

H

16 0.63 100 20 0.79 108 25 0.98 118 30 1.18 128 35 1.38 138 38 1.50 144 40 1.57 148 45 1.77 158 50 1.97 168 60 2.36 188 63 2.48 194 70 2.76 208 75 2.95 218 80 3.15 228 90 3.54 248 100 3.94 268 125 4.92 318 *= at full stroke

C 84 88 93 98 103 106 108 113 118 128 131 138 143 148 158 168 193

I nitial

66,000

E nd force* 91,900 93,700 96,200 98,200 99,700 100,500 101,000 102,100 103,000 104,400 104,800 105,500 105,900 106,400 107,100 107,600 108,700

Gas vol. (㎤)

Weight (k g)

272.3 315.7 370.1 424.4 478.7 511.3 533.1 587.4 641.8 750.4 783.0 859.1 913.4 967.8 1076.5 1185.1 1456.8

6.01 6.19 6.42 6.65 6.87 7.01 7.11 7.33 7.56 8.01 8.15 8.47 8.70 8.93 9.38 9.84 10.98

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP6600

Charging pressure(Bar)

Initial Force(N) 441.6

ex) What comes to the charging pressure of gas spring which demands force 60,000N?

136(Bar)

60,000(N) 441.6

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/28

26 - www.eoc.de


TSP6600 Mounts

NITROGEN GAS SPRING MD MOUNT

TSP6600 Mounts WELDED

MS MOUNT

38 2 × Ø13

140

165 197

114

114 140

4 × Ø13

20

MDB

WELDED

25

MSB

MDA

MSA

MK MOUNT 32

WELDED

XP6600(SP5000) MOUNT

32

109.5

4 × Ø13.5

140

146 174

109.5

24

25

26

140

19

12

32

XB6600(SB5000) MOUNT

XT6600(ST5000) MOUNT 130 109.5

20

4 × Ø13.5

140

4 × M10

130 109.5 36

M20 THRU

4 × Ø13.5

21

109.5

56.6

XR6600(SR5000) MOUNT Ø155

XC6600(SC5000) MOUNT 2 × Ø13 165 195 220

Ø175

115 36

109.5 21

4 × Ø13.5

M12

30

20

SHINWEON S&T CO.,LTD.

148

www.shinweon.com TSP/29

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

74

www.eoc.de - 27


TSP9500

TSP9500

NITROGEN GAS SPRING

STROKE

M8 Maintenance only

4 x M10 DP13 Charge Port G1/8

TSP9500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

XP9500

REPAIR KIT

RCX9500

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SP 9500 (inch)

H

20 0.79 118 25 0.98 128 30 1.18 138 35 1.38 148 38 1.50 154 40 1.57 158 45 1.77 168 50 1.97 178 60 2.36 198 63 2.48 204 70 2.76 218 75 2.95 228 80 3.15 238 258 90 3.54 100 3.94 278 125 4.92 328 *= at full stroke

C 98 103 108 113 116 118 123 128 138 141 148 153 158 168 178 203

I nitial

95,000

E nd force* 127,600 131,000 133,700 135,900 137,000 137,700 139,200 140,500 142,600 143,100 144,200 144,900 145,500 146,500 147,400 149,100

Gas vol. (㎤)

Weight (k g)

509.9 591.6 673.3 755.0 804.0 836.6 918.3 1000.0 1163.3 1212.3 1326.7 1408.4 1490.0 1653.4 1816.7 2225.1

10.78 11.10 11.60 12.84 13.18 13.24 14.48 14.70 15.50 15.64 16.20 17.30 18.10 19.60 20.44 21.20

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSP9500

Charging pressure(Bar)

Initial Force(N) 635.9

ex) What comes to the charging pressure of gas spring which demands force 85,000N?

134(Bar)

85,000(N) 635.9

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSP/30

28 - www.eoc.de


TSP9500 Mounts

NITROGEN GAS SPRING MS MOUNT

TSP9500 Mounts WELDED

178

XB9500(SB7500) MOUNT

140 25 140

4 × Ø17.5

178

4 × Ø17.5

MSB

4 × M10

M20 THRU

190

MSA

138

25

70.7

XR9500(SR7500) MOUNT

XT9500(ST7500) MOUNT

Ø195

162 138

Ø220 162 138

138 41

4 × Ø17.5 4 × Ø17.5 41

27

XP9500(SP7500) MOUNT 190 138

190

4 × Ø17.5

27

XC9500(SC7500) MOUNT 2 × Ø13

200 230 260

138 135 24 M12

12

30

200

20 100

SHINWEON S&T CO.,LTD.

www.shinweon.com TSP/31

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 29


TSM Series

www.eoc.de

22/03/2011

NITROGEN


TSM Series

TOSS GAS SPRING

NITROGEN GAS SPRING

CONTENTS

TSM-SERIES TSM0150 TSM0300 TSM0500 TSM0750 TSM1500 TSM3000 TSM5000 COMPACT TYPE

■ Specification

TYPE

■ General Specification ● Filling Materials Nitrogen GAs(N2)

● Maximum Stroke Rate Per Minute (Recommended) ~50 to 100 (at 20℃)

● Maximum Filling Pressure ● Piston Rod Speed 150~175 bar (at 20℃) ●Minimum Filling Pressure 25 bar (at 20℃) ● Operation Temperature

0.03~0.8 m/s ● Rod Surface Treatment Nitrate Coating

Stroke (mm)

Cylinder Diameter Φ(mm)

TSM0150

Rod Φ(mm)

Initial Force (N)

End Force (N)

MAX. Charging Pressure

P34 Reference P34 Reference P34 Reference

TSM0300 TTM0300 TSM0500 TSM0750

● Cylinder Surface Treatment TSM1500

-5 to 80℃

Oxidized Black Coating

● Pressure Increase as per Temperature ±0.3% / ℃

TSM3000 TSM5000

22/03/2011

※ The above specification is subject to change without notice for performance improvement.

www.eoc.de - 31


TSM0150

TSM0150

NITROGEN GAS SPRING

STROKE

YELLOW

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0150

REPAIR KIT

Non-repairable

(inch)

10 0.39 62 13 0.51 68 15 0.59 72 16 0.63 74 20 0.79 82 25 0.98 92 30 1.18 102 35 1.38 112 38 1.50 118 40 1.57 122 45 1.77 132 142 50 1.97 60 2.36 165 63 2.48 172 70 2.76 185 80 3.15 205 100 3.94 245 125 4.92 295 *= at full stroke

C 52 55 57 58 62 67 72 77 80 82 87 92 105 109 115 125 145 170

(175·135·90·45 bar / +20℃ )

E nd force* 2,600 2,700 2,700 2,700 2,700 2,800 2,800 2,800 2,800 2,800 2,800 2,800 2,900 2,800 2,900 2,900 2,900 2,900

E nd force* 2,000 2,000 2,000 2,000 2,100 2,100 2,100 2,100 2,100 2,100 2,100 2,100 2,100 2,100 2,200 2,200 2,200 2,200

E nd force* 1,300 1,300 1,300 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400 1,400

E nd force* 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700

※ Special type is available upon requested. Note: All of EOC Normalien gas spring must be secured with a stroke reserved at least 10% of the length of the stroke. Not allowed disassembled in any case without manufacture’s instructions.

Gas vol. (㎤)

weight (k g)

4.7 5.7 6.4 6.8 8.1 9.9 11.6 13.3 14.4 15.1 16.8 18.5 22.0 23.4 25.4 28.9 35.8 44.5

0.14 0.15 0.16 0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 0.24 0.27 0.27 0.29 0.32 0.36 0.40

FORCE (N)

(㎜)

■ FORCE CHART

F orce(N)

H

GREEN

CHARGING PRESSURE (Bar)

T SM 0150 Strok e

BLUE

175(YELLOW)

TSM0150

GAS SPRING

RED

STROKE (%)

TSM0150 is pre-charged when shipped and comes in four types , depending on the force. The pressure cannot be adjusted but Nitrogen is rechargeable.

Color

Force (N)

bar

YELLOW RED BLUE

22/03/2011

GREEN

32 - www.eoc.de


TSM0150 Mounts

NITROGEN GAS SPRING SP0150 MOUNT

TSM0150 Mounts SR0150 MOUNT

40 28

40

Ø38

28

Ø50

4 × Ø7

5

4 × Ø7 26.9

21.5 5.5 9

SG0150 MOUNT

SB0150 MOUNT 40

50

28 18

40

28

34

30

4 × Ø7

5 × Ø7

21.5 20 9

SHINWEON S&T CO.,LTD.

www.shinweon.com TSM/35

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 33


TSM0300

TSM0300

NITROGEN GAS SPRING

STROKE M6

2 x M6 DP6

Charge Port M6

TSP0300

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0300

REPAIR KIT

RCM0300

SELF CONTAINED-S FITTING-SYSTEM-F

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SM0300 (inch)

H

10 0.39 70 15 0.59 80 20 0.79 90 25 0.98 100 30 1.18 110 35 1.38 120 38 1.50 126 40 1.57 130 45 1.77 140 50 1.97 150 60 2.36 170 63 2.48 176 70 2.76 190 80 3.15 210 90 3.54 230 100 3.94 250 110 4.33 270 120 4.72 290 125 4.92 300 *= at full stroke

C 60 65 70 75 80 85 88 90 95 100 110 113 120 130 140 150 160 170 175

I nitial

3,000

E nd force* 3,900 4,000 4,000 4,100 4,100 4,100 4,100 4,100 4,100 4,100 4,100 4,100 4,100 4,100 4,100 4,200 4,200 4,200 4,200

Gas vol. (㎤)

weight (k g)

8.5 12.0 15.5 19.1 22.6 26.1 28.3 29.7 33.2 36.7 43.8 45.9 50.9 57.9 65.0 72.1 79.1 86.2 89.7

0.44 0.46 0.50 0.52 0.56 0.58 0.58 0.60 0.62 0.66 0.70 0.72 0.76 0.80 0.84 0.90 0.96 1.00 1.04

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSM0300

Charging pressure(Bar)

Initial Force(N) 20.1

ex) What comes to the charging pressure of gas spring which demands force 2,500N?

※ Special type is available upon requested.

124(Bar)

2,500(N) 20.1

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/36

34 - www.eoc.de


TSM0300 Mounts

TSM0300 Mounts

NITROGEN GAS SPRING SP0300 MOUNT

SR0300 MOUNT

55 40

Ø56.5 Ø68

55 40

12

4 × Ø7

4 × Ø7

17

40 9

6.5

SC0300 MOUNT

ST0300 MOUNT 52 40

2 × Ø9 59 77 95

52 40 53 17

M6 20

4 × Ø7

9

27.5 50.3 20

TTM0300 (Threaded Option) H ±0.2 ST

C

+ 0.0 -0.2

M6

25

Ø16

2 × M6 DP6

M38×1.5

SN0300 MOUNT For TTM0300

SG0300 MOUNT For TTM0300 29

M38×1.5 47

Ø75

50

50 8

M38×1.5

4 × Ø9

12

16

SHINWEON S&T CO.,LTD.

www.shinweon.com TSM/37

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 35


TSM0500

TSM0500

NITROGEN GAS SPRING

STROKE M8

2 x M8 DP6

Charge Port M6

TSM0500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0500

REPAIR KIT

RCM0500

SELF CONTAINED-S FITTING-SYSTEM-F

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SM0500 (inch)

H

10 0.39 70 15 0.59 80 20 0.79 90 25 0.98 100 30 1.18 110 35 1.38 120 38 1.50 126 40 1.57 130 45 1.77 140 50 1.97 150 60 2.36 170 63 2.48 176 70 2.76 190 80 3.15 210 90 3.54 230 100 3.94 250 110 4.33 270 120 4.72 290 125 4.92 300 *= at full stroke

C 60 65 70 75 80 85 88 90 95 100 110 113 120 130 140 150 160 170 175

I nitial

4,650

E nd force* 6,100 6,200 6,300 6,300 6,400 6,400 6,400 6,400 6,400 6,400 6,500 6,500 6,500 6,500 6,500 6,500 6,500 6,500 6,500

Gas vol. (㎤)

weight (k g)

12.9 18.3 23.6 29.0 34.4 39.8 43.0 45.1 50.5 55.9 66.6 69.9 77.4 88.1 98.9 109.6 120.4 131.1 136.5

0.60 0.64 0.68 0.72 0.76 0.80 0.81 0.82 0.86 0.89 0.96 0.98 1.01 1.09 1.16 1.23 1.30 1.35 1.39

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSM0500

Charging pressure(Bar)

Initial Force(N) 31.4

ex) What comes to the charging pressure of gas spring which demands force 4,000N?

※ Special type is available upon requested.

127(Bar)

4,000(N) 31.4

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/38

36 - www.eoc.de


TSM0500 Mounts

NITROGEN GAS SPRING SP0500 MOUNT

TSM0500 Mounts SR0500 MOUNT

70 50

Ø70.7

Ø86

70 50

4 × Ø9 20

50

4 × Ø9 23 13

6.5

ST0500 MOUNT

SB0500 MOUNT

64 50

20

64 50

4 × Ø9 2 × M8 23

2 × Ø9 9

13 70 50

20 50 70

2 × M10

SC0500 MOUNT 2 × Ø9

66 82 100 54

20 M8

60 20 30

SHINWEON S&T CO.,LTD.

www.shinweon.com TSM/39

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 37


TSM0750

TSM0750

NITROGEN GAS SPRING

STROKE M8

2 x M8 DP6

Charge Port M6

TSM0750

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0750

REPAIR KIT

RCM0750

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

TSM0750 T SM0750 (inch)

H

10 0.39 70 12.7 0.50 75.4 15 0.59 80 20 0.79 90 25 0.98 100 30 1.18 110 35 1.38 120 38 1.50 126 40 1.57 130 45 1.77 140 50 1.97 150 60 2.36 170 63 2.48 176 70 2.76 190 75 2.95 200 80 3.15 210 90 3.54 230 100 3.94 250 125 4.92 300 *= at full stroke

C 60 62.7 65 70 75 80 85 88 90 95 100 110 113 120 125 130 140 150 175

I nitial

7,350

E nd force* 11,700 11,800 11,800 11,900 11,900 11,900 11,900 12,000 12,000 12,000 12,000 12,000 12,000 12,000 12,000 12,000 12,000 12,000 12,000

Gas vol. (㎤)

weight (k g)

13.2 16.6 19.5 25.7 32.0 38.3 44.6 48.4 50.9 57.1 63.4 76.0 79.8 88.5 94.8 101.1 113.7 126.2 157.6

0.75 0.78 0.80 0.86 0.92 0.94 1.02 1.04 1.06 1.10 1.14 1.24 1.26 1.34 1.38 1.43 1.53 1.62 1.84

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSM0750

Charging pressure(Bar)

Initial Force(N) 49.1

ex) What comes to the charging pressure of gas spring which demands force 6,000N?

※ Special type is available upon requested.

122(Bar)

6,000(N) 49.1

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/40

38 - www.eoc.de


TSM0750 Mounts

TSM0750 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø11

2 × Ø11 30

2 × Ø11 30

54

76 89 111

89 111

54 76

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C7

MK MOUNT

WELDED

WELDED

24

Ø90

24

4 × Ø11 68 89

Ø110

4 × Ø11 17

17

MRB MRA

12.7 19

20

C7

SP0750M MOUNT 75

56.5

75

ST0750 MOUNT

SB0750 MOUNT

4 × Ø9

70

56.5

56.5

4 × Ø9

70 56.5

20

24

13

2 × Ø9 24 6.5

75 56.5 2 × M8 20

SR0750 MOUNT

2 × M10

SC0750 MOUNT Ø80

2 × Ø9

Ø95

90 110 130 70

13

56.5

M8

4 × Ø9

30 40

24

80 20

SHINWEON S&T CO.,LTD.

www.shinweon.com TSM/41

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 39


TSM1500

TSM1500

NITROGEN GAS SPRING

STROKE M8

4 x M8 DP12 Charge Port G1/8

TSM1500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP1500

REPAIR KIT

RCM1500

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SM1500 (inch)

H

10 0.39 114 13 0.51 120 15 0.59 124 20 0.79 134 25 0.98 144 30 1.18 154 35 1.38 164 38 1.50 170 40 1.57 174 45 1.77 184 50 1.97 194 60 2.36 214 63 2.48 220 70 2.76 234 75 2.95 244 80 3.15 254 90 3.54 274 100 3.94 294 125 4.92 344 150 5.91 394 160 6.30 414 175 6.89 444 200 7.87 494 *= at full stroke

C 104 107 109 114 119 124 129 132 134 139 144 154 157 164 169 174 184 194 219 244 254 269 294

I nitial

15,150

E nd force* 19,000 19,500 19,700 20,200 20,500 20,800 20,900 21,000 21,100 21,200 21,300 21,500 21,500 21,600 21,600 21,700 21,800 21,800 21,900 22,000 22,000 22,100 22,100

Gas vol. (㎤)

weight (k g)

49.9 59.2 65.4 81.0 96.6 112.2 127.7 137.1 143.3 158.9 174.5 205.6 215.0 236.8 252.4 267.9 299.1 330.3 408.2 486.0 517.2 563.9 641.8

2.00 2.95 3.02 3.13 3.20 3.32 3.38 3.47 3.49 3.58 3.65 3.83 3.88 4.05 4.17 4.24 4.34 4.60 5.06 5.54 5.83 6.11 6.46

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSM1500

Charging pressure(Bar)

Initial Force(N) 101.7

ex) What comes to the charging pressure of gas spring which demands force 12,000N?

118(Bar)

12,000(N) 101.7

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/42

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

40 - www.eoc.de


TSM1500 Mounts

TSM1500 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

102 120 152

2 × Ø13 38

76

120 152

76 102

19

MTB 20

MDB MDA

MTA

25

MSB

WELDED

MSA

MR MOUNT

C9

MK MOUNT

WELDED

WELDED

26

Ø120

26

4 × Ø13 95 118

Ø152 4 × Ø13 23

19

MRB

23

MRA

19 32 C9

SP1500 MOUNT 100

73.5

100

ST1500 MOUNT

SB1500 MOUNT

90

4 × Ø11

73.5

73.5

90 73.5

20

24

29

4 × Ø11 M20 THRU 4 × M8

12

4 × Ø11 1

16

73.5 100

28.3

SR1500 MOUNT

SC1500 MOUNT Ø104

2 × Ø11

Ø122

115 137 160 4 × Ø11

29

73.5 16

85 M10 30 20

SHINWEON S&T CO.,LTD.

105

www.shinweon.com TSM/43

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

52.5

www.eoc.de - 41


TSM3000

TSM3000

NITROGEN GAS SPRING

STROKE M8

4 x M8 DP12 Charge Port G1/8

TSM3000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP3000

REPAIR KIT

RCM3000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SM3000 (inch)

H

10 0.39 114 13 0.51 120 15 0.59 124 20 0.79 134 25 0.98 144 30 1.18 154 35 1.38 164 38 1.50 170 40 1.57 174 45 1.77 184 50 1.97 194 60 2.36 214 63 2.48 220 70 2.76 234 75 2.95 244 80 3.15 254 90 3.54 274 100 3.94 294 125 4.92 344 150 5.91 394 160 6.30 414 175 6.89 444 200 7.87 494 *= at full stroke

C 104 107 109 114 119 124 129 132 134 139 144 154 157 164 169 174 184 194 219 244 254 269 294

I nitial

29,400

E nd force* 40,800 41,900 42,500 43,600 44,300 44,800 45,200 45,400 45,600 45,800 46,000 46,400 46,400 46,600 46,700 46,800 46,900 47,000 47,300 47,400 47,500 47,500 47,600

Gas vol. (㎤)

weight (k g)

70.3 85.4 95.5 120.6 145.7 170.8 195.9 211.0 221.1 246.2 271.3 321.5 336.6 371.8 396.9 422.0 472.3 522.5 648.1 773.7 823.9 899.3 1024.9

4.79 4.96 4.96 5.09 5.29 5.38 5.53 5.62 5.68 5.83 5.98 6.27 6.36 6.57 6.72 7.07 7.40 7.76 8.48 8.93 9.23 10.11 10.41

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSM3000

Charging pressure(Bar)

Initial Force(N) 196.2

ex) What comes to the charging pressure of gas spring which demands force 25,000N?

127(Bar)

25,000(N) 196.2

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/44

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

42 - www.eoc.de


TSM3000 Mounts

TSM3000 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

127 146 178

2 × Ø13 38

98

146 178

98 127

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C10

MK MOUNT

WELDED

WELDED

26

Ø140

26

4 × Ø13 115 137

Ø171 4 × Ø13 23

25

MRB

23

MRA

19 32 C10

SP3000 MOUNT 120 92

120

ST3000 MOUNT

SB3000 MOUNT

110

4 × Ø13.5

92

92

110 92

20

24

33

4 × Ø13.5 4 × M8

12

42.4

SR3000 MOUNT

18

92 120

M20 THRU

SC3000 MOUNT Ø130

2 × Ø13

Ø150

145 170 195 4 × Ø13.5

33

4 × Ø13.5 .5

92 18

102.5 M12 30 20

SHINWEON S&T CO.,LTD.

125

www.shinweon.com TSM/45

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

62.5

www.eoc.de - 43


TSM5000

TSM5000

NITROGEN GAS SPRING

STROKE M8

4 x M10 DP12 Charge Port G1/8

TSM5000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP5000

REPAIR KIT

RCM5000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SM5000 (inch)

H

10 0.39 117 13 0.51 123 15 0.59 127 20 0.79 137 25 0.98 147 30 1.18 157 35 1.38 167 38 1.50 173 40 1.57 177 45 1.77 187 50 1.97 197 60 2.36 217 63 2.48 223 70 2.76 237 75 2.95 247 80 3.15 257 90 3.54 277 100 3.94 297 125 4.92 347 150 5.91 397 160 6.30 417 175 6.89 447 200 7.87 497 *= at full stroke

C 107 110 112 117 122 127 132 135 137 142 147 157 160 167 172 177 187 197 222 247 257 272 297

I nitial

49,650

E nd force* 67,400 69,800 71,000 73,500 75,200 76,500 77,600 78,100 78,400 79,100 79,600 80,500 80,700 81,200 81,400 81,700 82,100 82,400 83,100 83,500 83,600 83,800 84,100

Gas vol. (㎤)

weight (k g)

125.6 149.2 164.9 204.1 243.4 282.6 321.9 345.4 361.1 400.4 439.6 518.1 541.7 596.6 635.9 675.1 753.6 832.1 1028.4 1224.6 1303.1 1420.9 1617.1

7.78 7.92 8.01 8.24 8.48 8.71 8.95 9.09 9.18 9.41 9.65 10.11 10.25 10.58 10.81 11.05 11.51 11.98 13.15 14.32 14.79 15.49 16.65

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSM5000

Charging pressure(Bar)

Initial Force(N) 331.7

ex) What comes to the charging pressure of gas spring which demands force 38,000N?

115(Bar)

38,000(N) 331.7

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/46

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

44 - www.eoc.de


TSM5000 Mounts

TSM5000 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

140 165 197

2 × Ø13 38

114

165 197

114 140

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C10

MK MOUNT

WELDED

WELDED

32

Ø165

32

4 × Ø17 146 174

Ø197 4 × Ø17 26

25

MRB

26

MRA

19 32 C10

SP5000 MOUNT 140

109.5

140

ST5000 MOUNT

SB5000 MOUNT

130

4 × Ø13.5

109.5

109.5

130 109.5

20

24 4 × M10

12

4 × Ø13.5 .5

36

4 × Ø13.5

21

109.5 140

56.6

SR5000 MOUNT

M20 THRU

SC5000 MOUNT Ø155

2 × Ø13

Ø175

165 195 220 4 × Ø13.5

36

109.5 21

115 M12 30 20

SHINWEON S&T CO.,LTD.

148

www.shinweon.com TSM/47

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

74

www.eoc.de - 45


TSS Series

www.eoc.de

22/03/2011

NITROGEN


TOSS GAS SPRING TSS Series

NITROGEN GAS SPRING

CONTENTS

TSS-SERIES TSS0750 TSS1500 TSS3000 TSS5000

TSS STANDARD

■ Specification

TYPE

■ General Specification ● Filling Materials Nitrogen GAs(N2)

● Maximum Stroke Rate Per Minute (Recommended) ~50 to 100 (at 20℃)

● Maximum Filling Pressure ● Piston Rod Speed 150~180 bar (at 20℃) ●Minimum Filling Pressure 25 bar (at 20℃) ● Operation Temperature -5 to 80℃

0.03~0.8 m/s ● Rod Surface Treatment

Stroke (mm)

Cylinder Diameter Φ(mm)

Rod Φ(mm)

Initial Force (N)

End Force (N)

MAX. Charging Pressure

TSS0750 TSS1500 TSS3000 TSS5000

Nitrate Coating ● Cylinder Surface Treatment Oxidized Black Coating

● Pressure Increase as per Temperature ±0.3% / ℃

22/03/2011

※ The above specification is subject to change without notice for performance improvement.

www.eoc.de - 47


TSS0750

TSS0750

NITROGEN GAS SPRING

STROKE M8

2 x M8 DP12 Charge Port G1/8

TSM1500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0750

REPAIR KIT

RCS0750

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SS0750 (inch)

H

10 0.39 90 12.7 0.50 95.4 15 0.59 100 20 0.79 110 25 0.98 120 30 1.18 130 35 1.38 140 38 1.50 146 40 1.57 150 45 1.77 160 50 1.97 170 60 2.36 190 63 2.48 196 70 2.76 210 75 2.95 220 80 3.15 230 90 3.54 250 100 3.94 270 125 4.92 320 150 5.91 370 160 6.30 390 175 6.89 420 200 7.87 470 *= at full stroke

C 80 82.7 85 90 95 100 105 108 110 115 120 130 133 140 145 150 160 170 195 220 230 245 270

I nitial

7,350

E nd force* 9,500 9,800 10,000 10,300 10,600 10,800 10,900 11,000 11,000 11,100 11,200 11,300 11,300 11,400 11,400 11,500 11,500 11,600 11,700 11,700 11,700 11,800 11,800

Gas vol. (㎤)

weight (k g)

21.4 24.7 27.6 33.9 40.2 46.5 52.8 56.5 59.0 65.3 71.6 84.2 87.9 96.7 103.0 109.3 121.8 134.4 165.8 197.2 209.8 228.6 260.0

1.00 1.00 1.02 1.06 1.12 1.16 1.20 1.24 1.26 1.30 1.36 1.45 1.48 1.52 1.60 1.64 1.74 1.82 2.04 2.30 2.37 2.52 2.76

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSS0750

Charging pressure(Bar)

Initial Force(N) 49.1

ex) What comes to the charging pressure of gas spring which demands force 6,000N?

122(Bar)

6,000(N) 49.1

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSM/50

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

48 - www.eoc.de


TSS0750 Mounts

TSS0750 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø11

2 × Ø11 30

76 89 111

2 × Ø11 30

54

89 111

54 76

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C7

MK MOUNT

WELDED

WELDED

24

Ø90

24

4 × Ø11 68 89

Ø110 4 × Ø11 17

19

MRB

17

MRA

12.7 20 C7

SP0750 MOUNT 75

56.5

75

ST0750 MOUNT

SB0750 MOUNT

70

4 × Ø9

56.5

56.5

70 56.5

20

24

24

2 × Ø9 2 × M8

12

20

SR0750 MOUNT

13

56.5 75 2 × M10

SC0750 MOUNT Ø80

2 × Ø9

Ø95

90 110 130 4 × Ø9

24

4 × Ø9

56.5 13

70 M8 30 20

SHINWEON S&T CO.,LTD.

80

www.shinweon.com TSS/51

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

40

www.eoc.de - 49


TSS1500

TSS1500

NITROGEN GAS SPRING

STROKE M8

4 x M8 DP12 Charge Port G1/8

TSS1500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP1500

REPAIR KIT

RCS1500

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SS1500 (inch)

H

10 0.39 122 13 0.51 127.4 15 0.59 132 20 0.79 142 25 0.98 152 30 1.18 162 35 1.38 172 38 1.50 178 40 1.57 182 45 1.77 192 50 1.97 202 60 2.36 222 63 2.48 228 70 2.76 242 75 2.95 252 80 3.15 262 90 3.54 282 100 3.94 302 125 4.92 352 150 5.91 402 160 6.30 422 175 6.89 452 200 7.87 502 250 9.84 602 300 11.8 702 *= at full stroke

C

I nitial

112 114.4 117 122 127 132 137 140 142 147 152 162 165 15,150 172 177 182 192 202 227 252 262 277 302 352 402

E nd force* 17,800 18,300 18,500 19,000 19,400 19,700 20,000 20,100 20,200 20,400 20,500 20,800 20,800 20,900 21,000 21,100 21,200 21,300 21,500 21,600 21,700 21,700 21,800 21,900 22,000

Gas vol. (㎤)

weight (k g)

68.5 76.0 84.1 99.7 115.3 130.9 146.4 155.8 162.0 177.6 193.2 224.3 233.7 255.5 271.1 286.6 317.8 349.0 426.8 504.7 535.9 582.6 660.5 816.3 972.1

3.06 3.09 3.13 3.24 3.33 3.42 3.50 3.59 3.62 3.70 3.80 3.99 4.06 4.16 4.28 4.34 4.56 4.73 5.20 5.62 5.80 6.16 6.50 7.39 8.27

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSS1500

Charging pressure(Bar)

Initial Force(N) 101.7

ex) What comes to the charging pressure of gas spring which demands force 12,000N?

118(Bar)

12,000(N) 101.7

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSS/52

50 - www.eoc.de


TSS1500 Mounts

TSS1500 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

102 120 152

2 × Ø13 38

76

120 152

76 102

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C9

MK MOUNT

WELDED

WELDED

26

Ø120

26

4 × Ø13 95 118

Ø152 4 × Ø13 23

19

MRB

23

MRA

19 32 C9

SP1500 MOUNT 100

73.5

100

ST1500 MOUNT

SB1500 MOUNT

90

4 × Ø11

73.5

73.5

90 73.5

20

24

29

4 × Ø11 4 × M8

12

28.3

SR1500 MOUNT

16

73.5 100

M20 THRU

SC1500 MOUNT Ø104

2 × Ø11

Ø122

115 137 160 4 × Ø11

29

4 × Ø11 1

73.5 16

85 M10 30 20

SHINWEON S&T CO.,LTD.

105

www.shinweon.com TSS/53

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

52.5

www.eoc.de - 51


TSS3000

TSS3000

NITROGEN GAS SPRING

STROKE M8

4 x M8 DP12 Charge Port G1/8

TSS3000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP3000

REPAIR KIT

RCS3000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SS3000 (inch)

H

10 0.39 122 13 0.51 127.5 15 0.59 132 20 0.79 142 25 0.98 152 30 1.18 162 35 1.38 172 38 1.50 178 40 1.57 182 45 1.77 192 50 1.97 202 60 2.36 222 63 2.48 228 70 2.76 242 75 2.95 252 80 3.15 262 90 3.54 282 100 3.94 302 125 4.92 352 150 5.91 402 160 6.30 422 175 6.89 452 200 7.87 502 250 9.84 602 300 11.8 702 *= at full stroke

C

I nitial

112 114.5 117 122 127 132 137 140 142 147 152 162 165 29,400 172 177 182 192 202 227 252 262 277 302 352 402

E nd force* 35,700 37,100 37,500 38,900 39,900 40,800 41,400 41,800 42,000 42,500 42,900 43,600 43,700 44,100 44,300 44,500 44,800 45,100 45,600 46,000 46,100 46,300 46,500 46,800 47,000

Gas vol. (㎤)

weight (k g)

110.5 123.1 135.6 160.8 185.9 211.0 236.1 251.2 261.2 286.4 311.5 361.7 376.8 412.0 437.1 462.2 512.4 562.7 688.3 813.9 864.1 939.5 1065.1 1316.3 1567.5

5.07 5.08 5.18 5.38 5.54 5.69 5.85 5.90 5.93 6.16 6.22 6.52 6.70 6.94 7.10 7.26 7.51 7.86 8.66 9.45 9.76 10.23 11.01 12.53 14.14

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSS3000

Charging pressure(Bar)

Initial Force(N) 196.2

ex) What comes to the charging pressure of gas spring which demands force 25,000N?

127(Bar)

25,000(N) 196.2

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSS/54

52 - www.eoc.de


TSS3000 Mounts

TSS3000 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

127 146 178

2 × Ø13 38

98

146 178

98 127

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C10

MK MOUNT

WELDED

WELDED

26

Ø140

26

4 × Ø13 115 137

Ø171 4 × Ø13 23

25

MRB

23

MRA

19 32 C10

SP3000 MOUNT 120 92

120

ST3000 MOUNT

SB3000 MOUNT

110

4 × Ø13.5

92

92

110 92

20

24

33

4 × Ø13.5 4 × M8

12

42.4

SR3000 MOUNT

18

92 120

M20 THRU

SC3000 MOUNT Ø130

2 × Ø13

Ø150

145 170 195 4 × Ø13.5

33

4 × Ø13.5 .5

92 18

102.5 M12 30 20

SHINWEON S&T CO.,LTD.

125

www.shinweon.com TSS/55

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

62.5

www.eoc.de - 53


TSS5000

TSS5000

NITROGEN GAS SPRING

STROKE M8

4 x M10 DP12 Charge Port G1/8

TSS5000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP5000

REPAIR KIT

RCS5000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SS5000 (inch)

H

10 0.39 121.5 13 0.51 127.5 15 0.59 132 20 0.79 142 25 0.98 152 30 1.18 162 35 1.38 172 38 1.50 178 40 1.57 182 45 1.77 192 50 1.97 202 60 2.36 222 63 2.48 228 70 2.76 242 75 2.95 252 80 3.15 262 90 3.54 282 100 3.94 302 125 4.92 352 150 5.91 402 160 6.30 422 175 6.89 452 200 7.87 502 250 9.84 602 300 11.81 702 *= at full stroke

C

I nitial

111.5 114.5 117 122 127 132 137 140 142 147 152 162 165 49,650 172 177 182 192 202 227 252 262 277 302 352 402

E nd force* 65,400 67,800 68,500 71,000 73,000 74,400 75,600 76,200 76,500 77,300 78,000 79,100 79,300 79,900 80,200 80,500 81,000 81,400 82,200 82,800 83,000 83,200 83,500 84,000 84,300

Gas vol. (㎤)

weight (k g)

137.4 160.9 180.6 219.8 259.1 298.3 337.6 361.1 376.8 416.1 455.3 533.8 557.4 612.3 651.6 690.8 769.3 847.8 1044.1 1240.3 1318.8 1436.6 1632.8 2025.3 2417.8

8.22 8.37 8.47 8.72 9.00 9.21 9.68 9.71 9.71 9.95 10.34 10.69 10.84 11.19 11.44 11.97 12.18 12.67 13.91 15.14 15.63 16.38 17.61 20.08 22.55

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSS5000

Charging pressure(Bar)

Initial Force(N) 331.7

ex) What comes to the charging pressure of gas spring which demands force 38,000N?

115(Bar)

38,000(N) 331.7

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSS/56

54 - www.eoc.de


TSS5000 Mounts

TSS5000 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

140 165 197

2 × Ø13 38

114

165 197

114 140

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C10

MK MOUNT

WELDED

WELDED

32

Ø165

32

4 × Ø17 146 174

Ø197 4 × Ø17 26

25

MRB

26

MRA

19 32 C10

SP5000 MOUNT 140

109.5

140

ST5000 MOUNT

SB5000 MOUNT

130

4 × Ø13.5

109.5

109.5

130 109.5

20

24 4 × M10 12

4 × Ø13.5 .5

36

4 × Ø13.5

21

109.5 140

56.6

SR5000 MOUNT

M20 THRU

SC5000 MOUNT Ø155

2 × Ø13

Ø175

165 195 220 4 × Ø13.5

36

109.5 21

115 M12 30 20

SHINWEON S&T CO.,LTD.

148

www.shinweon.com TSS/57

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

74

www.eoc.de - 55


TSL Series

www.eoc.de

22/03/2011

NITROGEN


NITROGEN GAS SPRING

TOSS GAS SPRING TSL Series

■ Specification

TYPE

■ General Specification ● Filling Materials Nitrogen GAs(N2)

● Maximum Stroke Rate Per Minute (Recommended) ~50 to 100 (at 20℃)

● Maximum Filling Pressure ● Piston Rod Speed 150~180 bar (at 20℃) ●Minimum Filling Pressure 25 bar (at 20℃) ● Operation Temperature

0.03~0.8 m/s ● Rod Surface Treatment Nitrate Coating

Stroke (mm)

Cylinder Diameter Φ(mm)

Rod Φ(mm)

Initial Force (N)

End Force (N)

MAX. Charging Pressure

TSL0500 TSL0750 TSL1500 TSL3000 TSL5000

● Cylinder Surface Treatment TSL7500

-5 to 80℃

Oxidized Black Coating

● Pressure Increase as per Temperature

TSL10000

±0.3% / ℃

22/03/2011

※ The above specification is subject to change without notice for performance improvement.

www.eoc.de - 57


TSL0500

TSL0500

NITROGEN GAS SPRING

M8

2 x M8 DP6

Charge Port G1/8

TSL0500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0500

REPAIR KIT

RCL0500

SELF CONTAINED-S FITTING-SYSTEM-F

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 0500 (inch)

H

10 0.39 105 15 0.59 115 20 0.79 125 25 0.98 135 30 1.18 145 35 1.38 155 38 1.50 161 40 1.57 165 45 1.77 175 50 1.97 185 60 2.36 205 63 2.48 211 70 2.76 225 80 3.15 245 90 3.54 265 100 3.94 285 110 4.33 305 120 4.72 325 125 4.92 335 160 6.30 405 *= at full stroke

C 95 100 105 110 115 120 123 125 130 135 145 148 155 165 175 185 195 205 210 245

I nitial

4,650

E nd force* 5,100 5,300 5,400 5,500 5,600 5,700 5,700 5,700 5,800 5,800 5,900 5,900 6,000 6,000 6,100 6,100 6,100 6,200 6,200 6,200

Gas vol. (㎤)

Weight (k g)

33.9 39.2 44.6 50.0 55.3 60.7 63.9 66.1 71.5 76.8 87.6 90.8 98.3 109.1 119.8 130.6 141.3 152.1 157.4 195.1

0.89 0.94 0.98 0.98 1.10 1.13 1.16 1.16 1.19 1.21 1.23 1.25 1.31 1.38 1.45 1.51 1.58 1.64 1.67 1.89

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSL0500 √

Charging pressure(Bar)

Initial Force(N) 31.4

ex) What comes to the charging pressure of gas spring which demands force 4,000N?

※ Special type is available upon requested.

127(Bar)

4,000(N) 31.4

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/60

58 - www.eoc.de


TSL0500 Mounts

NITROGEN GAS SPRING SP0500 MOUNT

TSL0500 Mounts SR0500 MOUNT

70

Ø70.7

50

Ø86 70 50

4 × Ø9

20

50

4 × Ø9

13 23

6.5

ST0500 MOUNT

SB0500 MOUNT

64 50

64 50 20 4 × Ø9 13

2 × M8

2 × Ø9

23

70 50

20 50 70

2 × M10

SC0500 MOUNT 2 × Ø9

66 82 100 54

20 M8

60 20 30

SHINWEON S&T CO.,LTD.

www.shinweon.com TSL/61

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 59


TSL0750

TSL0750

NITROGEN GAS SPRING

STROKE M8

2 x M8 DP12 Charge Port G1/8

TSL0750

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP0750

REPAIR KIT

RCL0750

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 0750 (inch)

H

10 0.39 115 12.7 0.50 120.4 15 0.59 125 20 0.79 135 25 0.98 145 30 1.18 155 35 1.38 165 38 1.50 171 40 1.57 175 45 1.77 185 50 1.97 195 60 2.36 215 63 2.48 222 70 2.76 235 75 2.95 245 80 3.15 255 90 3.54 275 100 3.94 295 125 4.92 345 150 5.91 395 160 6.30 415 175 6.89 445 200 7.87 495 250 9.84 595 300 11.81 695 *= at full stroke

C 105 107.7 110 115 120 125 130 133 135 140 145 155 158 165 170 175 185 195 220 245 255 270 295 345 395

I nitial

7,350

E nd force* 8,400 8,600 8,700 9,000 9,300 9,500 9,700 9,800 9,800 10,000 10,100 10,300 10,300 10,500 10,500 10,600 10,700 10,800 11,000 11,100 11,200 11,200 11,300 11,500 11,500

Gas vol. (㎤)

Weight (k g)

40.2 43.6 46.5 52.8 59.0 65.3 71.6 75.4 77.9 84.2 90.4 103.0 106.8 115.6 121.8 128.1 140.7 153.2 184.6 216.0 228.6 247.4 278.8 341.6 404.4

1.32 1.34 1.35 1.40 1.44 1.50 1.54 1.58 1.59 1.64 1.68 1.78 1.82 1.87 1.91 1.98 2.06 2.14 2.30 2.61 2.72 2.84 3.08 3.60 4.07

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

√ PRESSURE (Bar)

■ Calculation of charging pressure for TSL0750

Charging pressure(Bar)

√ √ √

STROKE (%)

Initial Force(N) 49.1

ex) What comes to the charging pressure of gas spring which demands force 6,000N?

122(Bar)

6,000(N) 49.1

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/62

60 - www.eoc.de


TSL0750 Mounts

TSL0750 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø11

2 × Ø11 30

76 89 111

2 × Ø11 30

54

89 111

54 76

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C7

MK MOUNT

WELDED

WELDED

24

Ø90

24

4 × Ø11 68 89

Ø110 4 × Ø11 17

19

MRB

16

MRA

12.7 20 C7

SP0750 MOUNT 75

56.5

75

ST0750 MOUNT

SB0750 MOUNT

70

4 × Ø9

56.5

56.5

70 56.5

20

24

24

2 × Ø9 2 × M8

12

20

SR0750 MOUNT

13

56.5 75

2 × M10

SC0750 MOUNT Ø80

2 × Ø9

Ø95

90 110 130 4 × Ø9

24

4 × Ø9

56.5 13

70 M8 30 20

SHINWEON S&T CO.,LTD.

80

www.shinweon.com TSL/63

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

40

www.eoc.de - 61


TSL1500

TSL1500

NITROGEN GAS SPRING

STROKE M8

4 x M8 DP12 Charge Port G1/8

TSL1500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP1500

REPAIR KIT

RCL1500

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 1500 (inch)

H

10 0.39 130 13 0.51 135.4 15 0.59 140 20 0.79 150 25 0.98 160 30 1.18 170 35 1.38 180 38 1.50 186 40 1.57 190 45 1.77 200 50 1.97 210 60 2.36 230 63 2.48 237 70 2.76 250 75 2.95 260 80 3.15 270 90 3.54 290 100 3.94 310 125 4.92 360 150 5.91 410 160 6.30 430 175 6.89 460 200 7.87 510 250 9.84 610 300 11.81 710 *= at full stroke

C

I nitial

120 122.4 125 130 135 140 145 148 150 155 160 170 174 15,150 180 185 190 200 210 235 260 270 285 310 360 410

E nd force* 18,500 19,100 19,200 19,700 20,100 20,400 20,600 20,700 20,800 20,900 21,000 21,200 21,100 21,400 21,400 21,500 21,600 21,600 21,800 21,900 21,900 22,000 22,000 22,100 22,100

Gas vol. (㎤)

Weight (k g)

56.1 63.6 71.7 87.2 102.8 118.4 134.0 143.3 149.6 165.1 180.7 211.9 224.3 243.0 258.6 274.2 305.3 336.5 414.4 492.3 523.4 570.2 648.1 803.8 959.6

3.40 3.45 3.48 3.58 3.66 3.78 3.86 3.92 4.00 4.04 4.16 4.36 4.40 4.47 4.60 4.67 4.85 5.03 5.47 5.92 6.22 6.37 6.82 7.90 8.68

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

√ PRESSURE (Bar)

■ Calculation of charging pressure for TSL1500

Charging pressure(Bar)

√ √ √

STROKE (%)

Initial Force(N) 101.7

ex) What comes to the charging pressure of gas spring which demands force 12,000N?

118(Bar)

12,000(N) 101.7

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/64

62 - www.eoc.de


TSL1500 Mounts

TSL1500 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

102 120 152

2 × Ø13 38

76

120 152

76 102

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C9

MK MOUNT

WELDED

WELDED

26

Ø120

26

4 × Ø13 95 118

Ø152 4 × Ø13 23

19

MRB

23

MRA

19 32 C9

SP1500 MOUNT 100

73.5

100

ST1500 MOUNT

SB1500 MOUNT

90

4 × Ø11

73.5

73.5

90 73.5

20

24

29

4 × Ø11 4 × M8

12

28.3

SR1500 MOUNT

16

73.5 100

M20 THRU

SC1500 MOUNT Ø104

2 × Ø11

Ø122

115 137 160 4 × Ø11

29

4 × Ø11 1

73.5 16

85 M10 30 20

SHINWEON S&T CO.,LTD.

105

www.shinweon.com TSL/65

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

52.5

www.eoc.de - 63


TSL3000

TSL3000

NITROGEN GAS SPRING

STROKE M8

4 x M8 DP12 Charge Port G1/8

TSL3000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP3000

REPAIR KIT

RCL3000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 3000 (inch)

H

10 0.39 140 13 0.51 145.5 15 0.59 150 20 0.79 160 25 0.98 170 30 1.18 180 35 1.38 190 38 1.50 196 40 1.57 200 45 1.77 210 50 1.97 220 60 2.36 240 63 2.48 247 70 2.76 260 75 2.95 270 80 3.15 280 90 3.54 300 100 3.94 320 125 4.92 370 150 5.91 420 160 6.30 440 175 6.89 470 200 7.87 520 250 9.84 620 300 11.81 720 *= at full stroke

C

I nitial

130 132.5 135 140 145 150 155 158 160 165 170 180 184 29,400 190 195 200 210 220 245 270 280 295 320 370 420

E nd force* 37,000 38,500 38,900 40,200 41,200 42,000 42,600 42,900 43,100 43,600 43,900 44,500 44,300 44,900 45,100 45,300 45,600 45,800 46,200 46,500 46,600 46,700 46,900 47,200 47,300

Gas vol. (㎤)

Weight (k g)

95.5 108.0 120.6 145.7 170.8 195.9 221.1 236.1 246.2 271.3 296.4 346.7 366.8 396.9 422.0 447.1 497.4 547.6 673.2 798.8 849.1 924.4 1050.0 1301.2 1552.4

5.74 5.84 5.92 6.09 6.48 6.55 6.62 6.73 6.80 6.98 7.15 7.51 7.68 7.86 8.04 8.27 8.58 8.85 9.65 10.69 11.05 11.58 12.46 14.23 16.00

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

√ PRESSURE (Bar)

■ Calculation of charging pressure for TSL3000

Charging pressure(Bar)

√ √ √

STROKE (%)

Initial Force(N) 196.2

ex) What comes to the charging pressure of gas spring which demands force 25,000N?

127(Bar)

25,000(N) 196.2

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/66

64 - www.eoc.de


TSL3000 Mounts

TSL3000 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

127 146 178

2 × Ø13 38

98

146 178

98 127

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C10

MK MOUNT

WELDED

WELDED

26

Ø140

26

4 × Ø13 115 137

Ø171 4 × Ø13 23

25

MRB

23

MRA

19 32 C10

SP3000 MOUNT 120 92

120

ST3000 MOUNT

SB3000 MOUNT

110

4 × Ø13.5

92

92

110 92

20

24

33

4 × Ø13.5 4 × M8

12

42.4

SR3000 MOUNT

18

92 120

M20 THRU

SC3000 MOUNT Ø130

2 × Ø13

Ø150

145 170 195 4 × Ø13.5

33

4 × Ø13.5 .5

92 18

102.5 M12 30 20

SHINWEON S&T CO.,LTD.

125

www.shinweon.com TSL/67

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

62.5

www.eoc.de - 65


TSL5000

TSL5000

NITROGEN GAS SPRING

STROKE M8

4 x M10 DP12 Charge Port G1/8

TSL5000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP5000

REPAIR KIT

RCL5000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 5000 (inch)

H

10 0.39 159.5 13 0.51 165.5 15 0.59 170 20 0.79 180 25 0.98 190 30 1.18 200 35 1.38 210 38 1.50 216 40 1.57 220 45 1.77 230 50 1.97 240 60 2.36 260 63 2.48 266 70 2.76 280 75 2.95 290 80 3.15 300 90 3.54 320 100 3.94 340 125 4.92 390 150 5.91 440 160 6.30 460 175 6.89 490 200 7.87 540 250 9.84 640 300 11.81 740 *= at full stroke

C

I nitial

149.5 152.5 155 160 165 170 175 178 180 185 190 200 203 49,650 210 215 220 230 240 265 290 300 315 340 390 440

E nd force* 63,300 65,600 66,500 69,100 71,000 72,600 73,900 74,500 74,900 75,800 76,500 77,800 78,100 78,700 79,100 79,400 80,000 80,500 81,400 82,100 82,300 82,600 83,000 83,500 83,900

Gas vol. (㎤)

Weight (k g)

153.1 176.6 196.3 235.5 274.8 314.0 353.3 376.8 392.5 431.8 471.0 549.5 573.1 628.0 667.3 706.5 785.0 863.5 1059.8 1256.0 1334.5 1452.3 1648.5 2041.0 2433.5

10.32 10.71 11.10 11.49 11.88 12.27 12.66 13.00 13.44 13.83 14.22 14.68 15.07 15.46 15.85 16.24 16.94 17.66 18.05 18.44 18.83 19.22 19.61 20.31 21.01

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

√ PRESSURE (Bar)

■ Calculation of charging pressure for TSL5000

Charging pressure(Bar)

√ √ √

STROKE (%)

Initial Force(N) 331.7

ex) What comes to the charging pressure of gas spring which demands force 38,000N?

115(Bar)

38,000(N) 331.7

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/68

66 - www.eoc.de


TSL5000 Mounts

TSL5000 Mounts

NITROGEN GAS SPRING MD MOUNT

WELDED

MS MOUNT

MT MOUNT

WELDED 4 × Ø13

2 × Ø13 38

140 165 197

2 × Ø13 38

114

165 197

114 140

19

MTB 20

MDB

MTA

25

MSB

MDA

WELDED

MSA

MR MOUNT

C10

MK MOUNT

WELDED

WELDED

32

Ø165

32

4 × Ø17 146 174

Ø197 4 × Ø17 26

25

MRB

26

MRA

19 32 C10

SP5000 MOUNT 140

109.5

140

ST5000 MOUNT

SB5000 MOUNT

130

4 × Ø13.5

109.5

109.5

130 109.5

20

24 4 × M10

12

4 × Ø13.5 .5

36

4 × Ø13.5

21

109.5 140

56.6

SR5000 MOUNT

M20 THRU

SC5000 MOUNT Ø155

2 × Ø13

Ø175

165 195 220 4 × Ø13.5

36

109.5 21

115 M12 30 20

SHINWEON S&T CO.,LTD.

148

www.shinweon.com TSL/69

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

74

www.eoc.de - 67


TSL7500

TSL7500

NITROGEN GAS SPRING

STROKE M8

4 x M10 DP12 Charge Port G1/8

TSL7500

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP7500

REPAIR KIT

RCL7500

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 7500 (inch)

H

15 0.59 185 20 0.79 195 25 0.98 205 30 1.18 215 35 1.38 225 38 1.50 231 40 1.57 235 45 1.77 245 50 1.97 255 60 2.36 275 63 2.48 282 70 2.76 295 75 2.95 305 80 3.15 315 90 3.54 335 100 3.94 355 125 4.92 405 150 5.91 455 160 6.30 475 175 6.89 505 200 7.87 555 250 9.84 655 300 11.81 755 *= at full stroke

C 170 175 180 185 190 193 195 200 205 215 219 225 230 235 245 255 280 305 315 330 355 405 455

I nitial

75,300

E nd force* 96,400 100,100 103,000 105,400 107,300 108,300 109,000 110,300 111,500 113,500 113,200 115,000 115,600 116,200 117,200 118,100 119,700 120,800 121,200 121,600 122,300 123,200 123,900

Gas vol. (㎤)

Weight (k g)

343.4 404.8 466.1 527.4 588.8 625.5 650.1 711.4 772.7 895.4 944.5 1018.0 1079.4 1140.7 1263.4 1386.0 1692.7 1999.3 2122.0 2305.9 2612.6 3225.9 3839.1

16.80 18.40 21.20 22.45 23.20 24.20 25.20 26.90 27.90 29.50 30.50 31.80 33.20 34.40 35.40 36.50 37.40 38.50 39.40 40.40 41.70 42.60 43.70

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSL7500 √

Charging pressure(Bar)

√ √ √

Initial Force(N) 502.4

ex) What comes to the charging pressure of gas spring which demands force 65,000N?

129(Bar)

65,000(N) 502.4

※ Special type is available upon requested.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/70

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strokee Strok

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

68 - www.eoc.de


TSL7500 Mounts

NITROGEN GAS SPRING MS MOUNT

WELDED

SB7500 MOUNT

SR7500 MOUNT

ST7500 MOUNT

SP7500 MOUNT

SC7500 MOUNT

SHINWEON S&T CO.,LTD.

www.shinweon.com TSL/71

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 69


TSL10000

TSL10000

NITROGEN GAS SPRING

STROKE M8

4 x M12 DP12 Charge Port G1/8

TSL10000

GAS SPRING

STROKE

MODEL

HOW TO SPECIFY

MOUNT

SP10000

REPAIR KIT

RCL10000

SELF CONTAINED-S FITTING-SYSTEM-F

MOUNT

CHARGING PRESSURE (Bar)

[Caution!] Charging pressure has to be specified. Otherwise, 150Bar will be charged.

T SL 10000 (inch)

H

20 0.79 200 25 0.98 210 30 1.18 220 35 1.38 230 38 1.50 236 40 1.57 240 45 1.77 250 50 1.97 260 60 2.36 280 63 2.48 287 70 2.76 300 75 2.95 310 80 3.15 320 90 3.54 340 100 3.94 360 125 4.92 410 150 5.91 460 160 6.30 480 175 6.89 510 200 7.87 560 250 9.84 660 300 11.81 760 *= at full stroke

C 180 185 190 195 198 200 205 210 220 223 230 235 240 250 260 285 310 320 335 360 410 460

I nitial

106,200

E nd force* 137,600 140,400 142,500 144,200 145,100 145,600 146,700 147,700 149,200 149,600 150,300 150,800 151,200 152,000 152,600 153,700 154,500 154,700 155,100 155,500 156,100 156,600

Gas vol. (㎤)

Weight (k g)

619.8 726.6 833.5 940.4 1004.5 1047.2 1154.1 1260.9 1474.6 1538.8 1688.4 1795.2 1902.1 2115.8 2329.5 2863.8 3398.1 3611.8 3932.4 4466.7 5535.3 6603.8

36.20 38.50 40.20 42.50 44.10 45.60 47.90 48.80 50.90 51.70 53.20 55.45 57.00 59.50 61.80 64.50 67.20 69.00 72.30 74.50 80.50 86.50

PRESSURE (Bar)

STROKE (%)

■ Calculation of charging pressure for TSL10000 √

Charging pressure(Bar)

√ √ √ √ √ √

Initial Force(N) 708.5

ex) What comes to the charging pressure of gas spring which demands force 85,000N?

120(Bar)

※ Special type is available upon requested.

85,000(N) 708.5

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

22/03/2011

www.shinweon.com TSL/72

INCREASING RATIO

(㎜)

F orce(N)

( 150 bar / +20 ℃ )

FORCE (N)

Strok e

■ CHARGING PRESSURE/FORCE INCREASE FACTOR

70 - www.eoc.de


TSL10000 Mounts

NITROGEN GAS SPRING MS MOUNT

SP10000 MOUNT

SB10000 MOUNT

ST10000 MOUNT

SHINWEON S&T CO.,LTD.

www.shinweon.com TSL/73

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

WELDED

www.eoc.de - 71


Control Panels

CONTROL PANEL

NITROGEN GAS SPRING

PAN3 PAN3 is used to check charging pressure, to charge gas and to discharge gas spring. It has 3 connection ports for fitting type gas spring. Gas should be charged through the charging plug. Gas spring is discharged when you open the valve to exhaust gas. Never charge with any other than Nitrogen (N2).

3 x Φ11 MOUNTING HOLES

3 x G 1/8 PORT CHARGING PLUG VC11

EXHAUST VALVE VT11

PRESSURE GAUGE GAU350

PAN3 USE EXAMPLE

HOSE HO104

PORT ADAPTOR

90˚ SWIVEL HF190

GF118

45˚ SWIVEL HF145

STRAIGHT SWIVEL HF100 PORT ADAPTOR GF118

HOSE

H0104

PAN3 + FITTING CONNECTION

1 PORT USE

2 PORT USE

SHINWEON S&T CO.,LTD.

3 PORT USE

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved 22/03/2011

www.shinweon.com 74

STRAIGHT SWIVEL HF100

72 - www.eoc.de


Control Panels

NITROGEN GAS SPRING

CONTROL PANEL PAN6

PAN6 is CONTROL PANEL for COMPACT FITTING. It is used to check charging pressure, to charge and to discharge gas spring. Never charge with any other than Nitrogen (N2).

130

52 4 x Ø7 MOUNTING HOLES

6,25

106

7 PRESSURE GAUGE GAU350 EXHAUST VALVE VT11

CHARGING PLUG VC11

75 12

42,5

45

23 12 x M6 PORT

PAN6 USE EXAMPLE

HOSE HO055

PORT ADAPTOR CF111

PORT ADAPTOR CF111

ELBOW PORT ADAPTOR CF090

STRAIGHT SWIVEL CF100 HOSE HO055

PAN6 + FITTING CONNECTION

VERTICALITY FIX 5 PORT USE

VERTICALITY FIX 7 PORT USE

SHINWEON S&T CO.,LTD.

HORIZONTALITY FIX 7 PORT USE

www.shinweon.com 75

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

STRAIGHT SWIVEL CF100

www.eoc.de - 73


Multi Panel

MULTI PANEL

NITROGEN GAS SPRING

PSS SERIES PSS MULTI PANEL is used when single mold needs multiple pressures. Depends on model, it can be used from 2 lines to 8 lines of different pressure as a customer needs.

PSS-2 PSS-3 PSS-4 PSS-5 PSS-6 PSS-7 PSS-8

4 x Φ9 MOUNTING HOLES

MODEL OPTIONAL PORT G 1/8 MAIN EXHAUST VALVE VT11

PSS-2

LINE EXHAUST VALVE VT11 COVER

PSS-3 PSS-4

CHARGING

PSS-5 PSS-6 PSS-7 PSS-8

CHARGING PLUG VC11

PRESSURE GAUGE GAU350

HOW TO SPECIFY

HOW TO SPECIFY

PSS MULTI PANEL

Line

PSS USE EXAMPLE LINE

HOSE HO104

PORT ADAPTOR GF118

PORT ADAPTOR GF118

STRAIGHT SWIVEL HF100

STRAIGHT SWIVEL HF100

HOSE HO104

PSS-3 + FITTING CONNECTION

SHINWEON S&T CO.,LTD.

HORIZONTALITY FIX PORT USE Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved 22/03/2011

www.shinweon.com 76

VERTICALITY FIX PORT USE

74 - www.eoc.de


NITROGEN GAS SPRING

Distribution Block

DISTRIBUTION BLOCK DISTRIBUTION BLOCK

Distribution Block is able to be easily used for a connection of different shaped and built gas springs.

All distribution block is able to be customized by user’s needs.

HB-10

Distribution 10 Port Block HOSE STRAIGHT SWIVEL

G 1/8 (10x)

45˚ SWIVEL PORT ADAPTOR

PLUG

HB-10 USE EXAMPLE

CB-4

Compact 4 Block

HOSE STRAIGHT SWIVEL

PORT ADAPTOR

BRANCH TEE PORT ADAPTOR

CB-4 USE EXAMPLE

CB-12 Compact 12 Block HOSE HO055

PORT ADAPTOR CF111 STRAIGHT SWIVEL CF100

PLUG CP16

CB-12 USE EXAMPLE

SHINWEON S&T CO.,LTD.

www.shinweon.com 77

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 75


Compact Fitting

COMPACT FITTING

NITROGEN GAS SPRING

COMPACT FITTING COMPACT FITTING is the smallest size to make fitting system with HOSE HO055 in small area. Also, it is able to apply in variety situations with GF fitting.

MINIMUM BEND RADIUS R15

HOSE

WORKING PRESSURE 200bar BURST PRESSURE 800bar STRAIGHT SWIVEL CF100

GAS SPRING

STRAIGHT SWIVEL CF100

STRAIGHT SWIVEL CF100

PORT ADAPTOR CF111

GAS SPRING

O’RING

STRAIGHT SWIVEL CF100

minimum working length (compression preparation)

END PLUG CP18

PORT ADAPTOR CF111

G 1/8 PORT ADAPTOR CF118

PORT ADAPTOR EXTENSION CF110

UNION CTH10

G 1/8 - M8 UNION CF188

BRANCH TEE PORT ADAPTOR CF094

UNION TEE CTH93

SHINWEON S&T CO.,LTD.

PLUG CP16

RUN TEE PORT ADAPTOR CF093

UNION ELBOW CTH90 Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved 22/03/2011

www.shinweon.com 78

ELBOW PORT ADAPTOR CF090

7/16 PORT ADAPTOR CF716

completion

76 - www.eoc.de


GF Fitting

GF FITTING

NITROGEN GAS SPRING

GF FITTING GF FITTING is the most common fitting system

by using HOSE HO104. It can be installed in fitting system by variety combinations.

MINIMUM BEND RADIUS R30

WORKING PRESSURE 200bar BURST PRESSURE 700bar

STRAIGHT SWIVEL HF100

GAS SPRING

HOSE HO104 PORT ADAPTOR GF118

45˚ SWIVEL HF145

STRAIGHT SWIVEL HF100

FITTING + HOSE USE EXAMPLE GAS SPRING

O’ RING

90˚ SWIVEL HF190

FITTING + HOSE Combination Cross-Section View

PORT ADAPTOR GF118

PORT ADAPTOR GF111

SWIVEL NUT BRANCH TEE FS094

UNION HTH10

PLUG GP716

90˚ SWIVEL NUT ELBOW FS090

SWIVEL NUT RUN TEE FS093

UNION TEE HTH93

END PLUG GP100

UNION CROSS HTH94

SHINWEON S&T CO.,LTD.

UNION ELBOW HTH90

www.shinweon.com 79

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

PLUG GP118

www.eoc.de - 77


VF Fitting

VF FITTING

NITROGEN GAS SPRING

VF FITTING STRAIGHT SWIVEL VF100 HOSE HO104

GAS SPRING

VF FITTING with HOSE HO104 is fitting system that

uses a connection of surface contact without sealing . It can be installed in fitting system by combinations.

PORT ADAPTOR VG111

STRAIGHT SWIVEL VF100 GAS SPRING

45˚ SWIVEL VF145

7/16-20-UNF 90˚ SWIVEL VF190 7/16-20-UNF PORT ADAPTOR VG111

45˚ SWIVEL NUT ELBOW VS045

UNION VTH10

UNION TEE VTH93

SWIVEL NUT RUN TEE VS093

UNION CROSS VTH94

SHINWEON S&T CO.,LTD.

90˚ SWIVEL NUT ELBOW VS090

UNION ELBOW VTH90

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved 22/03/2011

www.shinweon.com 80

SWIVEL NUT BRANCH TEE VS094

78 - www.eoc.de


Charging Data

CHARGING DATA

NITROGEN GAS SPRING

CHARGING METHOD GAS SPRING for fitting system type can be charged through the charging plug on PANEL. For self-contained type, checking pressure and charging gas can be done by PRESSURE TESTER.

CONTROL PANEL PAN3

CONTROL PANEL PAN6

◆ Charging gas in PAN6 that applied fitting system. ◆ Charging gas in PAN3 that applied fitting system.

MULTI PANEL PSS3

◆ Charging gas for each line in PSS that applied fitting system.

MINIMUM BEND RADIUS R30

CM6 ◆ GAS SPRING TSP0170 ~ 0320 TSM0150 PRESSURE TESTER PT118

CHARGING PLUG VC1118

◆ Pressure tester is used for checking and charging gas pressure of self contained gas spring. VALVE VH48

PRESSURE REGULATOR GR300

CHARGING COUPLING GAS SPRING VC55 TSP0350 ~ TSP9500 TSM,TTM0300 ~ TSM5000 TSS0750 ~ TSS5000 TSL0500 ~ TSL10000

CHARGING ADAPTOR

PORT ADAPTOR CM618

NITROGEN GAS charger (length 3m) GCH100

N2

CHARGING PLUG VC1118

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

SHINWEON S&T CO.,LTD.

www.shinweon.com 81

www.eoc.de - 79


Accumulator

ACCUMULATOR

NITROGEN GAS SPRING

PRESSURE DISTRIBUTION TANK By connection with fitting system, EOC ACCUMULATOR keeps constant pressure level by minimize the difference between initial pressure and final pressure.

8 x G 1/8

DESCRIPTION

VOLUME

TAN050-25 TAN050-50 TAN050-75 TAN080-25 TAN080-50 TAN080-75 TAN125-25 TAN125-50 TAN125-75 TAN210-25

※ The formula for pressure ratio of EOC Accumulator System is seen on page 89.

TAN210-50

HOW TO SPECIFY

HOW TO SPECIFY

TAN Accumulator

Specification

ACCUMULATOR USE EXAMPLE

HOSE HO104

PORT ADAPTOR GF118

PORT ADAPTOR GF118 STRAIGHT SWIVEL HF100

STRAIGHT SWIVEL HF100

HOSE HO104

2 PORT USE

4 PORT USE

22/03/2011

ACCUMULATOR + FITTING CONNECTION

80 - www.eoc.de


Hose Manual

HOSE MANUAL

NITROGEN GAS SPRING

GF FITTING + HO104 HOSE CONNECTION

STRAIGHT

Compression Completion

Compression Preparation

STRAIGHT

GF FITTING SWIVEL Compression Cross-Section View

GF FITTING + HOSE HO104 application

COMPACT FITTING + HO055 HOSE CONNECTION Compression Completion

Compression Preparation

COMPACT FITTING

SWIVEL Compression Cross-Section View

COMPACT FITTING + HOSE HO055 application

◆ Fitting System Type GAS SPRING Example

STRAIGHT FITTING Combination Cross-Section View TORSION

INTERFERENCE

HOSE CLAMP

Use for fixing hose.

HCL10 HOSE_ HO104 Fixing

SHINWEON S&T CO.,LTD.

HCL48 HOSE_ HO104 Fixing

www.shinweon.com 83

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

HCL06 HOSE_ HO055 Fixing

www.eoc.de - 81


Fitting Example I

FITTING EXAMPLE I

NITROGEN GAS SPRING

HOSE HO104

PAN3

Application Piping Diagram I

No.

MODEL

STANDARD

GAS SPRING

TSP4200 x 060

PORT ADAPTOR

GF118

SWIVEL NUT RUN TEE FS093 45˚ SWIVEL HF145

GAS SPRING

HOSE CLAMP HCL10 PORT ADAPTOR GF118

90˚ SWIVEL NUT ELBOW

FS090

SWIVEL NUT BRANCH TEE

FS094

SWIVEL NUT RUN TEE

FS093

45˚ SWIVEL

HF145

STRAIGHT SWIVEL

STRAIGHT SWIVEL HF100

CONTROL PANEL PAN3

QTY. PAGE

HF100

HOSE CLAMP

HCL10

HOSE

HO104

CONTROL PANEL

PAN3

SWIVEL NUT BRANCH TEE FS094

90˚ SWIVEL NUT ELBOW FS090

Working notice (GF FITTING Application MODEL) When you apply Fitting system, secure more than 20mm to avoid tool interference.

PSS3

Application Piping Diagram I

No.

MODEL

STANDARD

QTY. PAGE

TSL1500 x 025-MSA

GAS SPRING

GAS SPRING

TSL1500 x 025-MDA TSL1500 x 025

PORT ADAPTOR

GF118

90˚ SWIVEL NUT ELBOW

FS090

UNION TEE

HTH93

SWIVEL NUT RUN TEE

FS093

STRAIGHT SWIVEL

HF100

90˚ SWIVEL

HF190

45˚ SWIVEL

HF145

HOSE MULTI PANEL

90˚ SWIVEL HF190 HOSE HO104

90˚ SWIVEL NUT ELBOW FS090 GAS SPRING

HO104

45˚ SWIVEL HF145

PSS3

SHINWEON S&T CO.,LTD.

SWIVEL NUT RUN TEE FS093

UNION TEE HTH93

GAS SPRING

PORT ADAPTOR GF118

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved 22/03/2011

www.shinweon.com 84

MULTI PANEL PSS3

STRAIGHT SWIVEL HF100

82 - www.eoc.de


NITROGEN GAS SPRING

Fitting Example II

FITTING EXAMPLE II

HOSE HO055

BRANCH TEE PORT ADAPTOR CF094

G 1/8 PORT ADAPTOR CF118

PAN6

Application Piping Diagram I

No.

MODEL

STANDARD

GAS SPRING

TSM1500 x 038

G 1/8 PORT ADAPTOR

CF118

BRANCH TEE PORT ADAPTOR

CF094

GAS SPRING

ELBOW PORT ADAPTOR

HOSE CLAMP HCL06

ELBOW PORT ADAPTOR CF090

CF090

HOSE CLAMP

HCL06

HOSE

HO055 PAN6

CONTROL PANEL

CONTROL PANEL PAN6

QTY. PAGE

Working notice (COMPACT FITTING Application MODEL) When you apply Fitting system, secure more than 15mm to avoid tool interference.

PORT ADAPTOR CF111 STRAIGHT SWIVEL CF100

GAS SPRING

PAN6

Application Piping Diagram II

No.

MODEL

STANDARD

GAS SPRING

TSP1000 x 030

PORT ADAPTOR

CF111

ELBOW PORT ADAPTOR

CF090

STRAIGHT SWIVEL

CF100

COMPACT 12 BLOCK

CB-12

HOSE

HO055

CONTROL PANEL

PAN6

HOSE HO055

QTY. PAGE

DISTRIBUTION BLOCK CB-12 ELBOW PORT ADAPTOR CF090 CONTROL PANEL PAN6

SHINWEON S&T CO.,LTD.

www.shinweon.com 85

22/03/2011

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved

www.eoc.de - 83


Charging Accessories

KARRYKRIMP HK8201

ASSEMBLING TOOL MARK10

Standard) HK8201

Standard) MARK10

ㆍHO104 Hose & Swivel hose adaptor presses ㆍKARRYKRIMP can combine HO104 Hose & Swivel hose adaptor Hose.

ㆍHO055 Hose & Straight Swivel presses ㆍAssembling tool can combine HO055 Hose and Straight Swivel. ㆍIt is easy to carry, so suitable for moving around work place.

GAS BOOSTERS S86JN

HOSE ASSEMBLY GCH100(Length:3m)

Standard) S86JN

Standard) GCH100

ㆍGas booster increases gas pressure ratio to user’s setting during charging gas of fitting

ㆍCharging Hose System

Pressure ratio (30:1)

HOSE SCISSORS HS10 Standard) HS10 ㆍHose Cutter

CHARGING COUPLING VC55 Standard) VC55

ㆍCross Pressure Tester ㆍPortable pressure tester is used for controlling and charging pressure of self contained type. ㆍPlease select correct model which fits to product.

CHARGING PLUG VC1118 (G 1/8) VC11716 (7/16) Standard) VC1118 ㆍCharging Male Plug ㆍIt combined with charging coupling to charge gas.

22/03/2011

ㆍCharging Female Coupling ㆍIt combined with charging plug to charge gas.

PRESSURE TESTER PT118 (G1/8 type) PT716 (7/16 type) Standard) PT118

84 - www.eoc.de


Repair Tools

COMPACT LOAD CELL CLC

DIGITAL LOAD CELL DLE10

Standard) CLC1500

Standard) DLE10

Standard

ㆍGas pressure gauge ㆍIt measures accurate pressure by placing on product. ㆍPlease select correct model which fits to product ㆍUnit - bar (0~350) - Mpa (0~35)

VALVE TIGHTEN TOOL VTT26R Standard) VTT26R ㆍTorque Driver ㆍUsed for assembly or disassembly of valve. ㆍAvoiding break a valve by Over Torque.

STOPRING REMOVAL TOOL SRT42 (0350~4200) SRT50 (5000~10000) Standard) SRT42 ㆍUsed to remove gas during disassembly gas spring. ㆍStopring can be removed by stopring removal tool after using valve control tool. ㆍPlease select correct model which fits product.

ㆍDigital load checking gauge ㆍIt measures load by placing gas spring on the gauge. ㆍLoad Range - 0 ~ 10t (0 ~1 00kN)

VALVE CONTROL TOOL VCT06(M6 type) VCT18(G 1/8 type) Standard) VCT06 ㆍGas Control Tool ㆍUsed for exhausting gas during disassembly gas spring. ㆍPlease select correct model which fits product.

T-REMOVAL TOOL TRT06(M6 type) TRT08 (M8 type) Standard) TRT06 ㆍGas Spring Disassembly Tool ㆍSequence ① Remove the gas to valve control tools ② Remove the ring by using the Stopring Removal Tool. ③ Isolates the Rod Ass’y from the cylinder using the T-Removal Tool. ㆍPlease select correct model which fits product.

PRESSURE GAUGE GAU350

VALVE CV100

Standard) GAU350

Standard) CV100

ㆍCompact Pressure Gauge

22/03/2011

ㆍUnit - bar (0~350) - Mpa (0~35)

ㆍCheck Valve ㆍWhen you change fitting system type gas spring to self-contained type, you can assemble or disassemble with valve tighten tool.

www.eoc.de - 85


Piping Change Procedure

PIPING CHANGE PROCEDURE NITROGEN GAS SPRING Self contained gas spring and fitting system type gas spring can be switched each other when condition of work changes.

Self-contained type

CHANGE Fitting System type

Self-contained type (M6 PORT)

Fitting System type

Self-contained type Assembly Drawing Preparing for switch to fitting system type PLUG CP16 (M6)

Remove plug from cylinder by using wrench.

APPLICATION MODEL TSP4200 TSP6600 TSP9500 TSM1500 TSM3000 TSM5000 TSS0750 TSS1500 TSS3000 TSS5000 TSL0500 TSL0750 TSL1500 TSL3000 TSL5000 TSL7500 TSL10000 TSP0350 TSP0500 TSP0750 TSP1500 TSP2400 TSM0300 TSM0500 TSM0750

wrench 4mm

Exhaust gas by pushing valve with Valve Control Tool.

Fitting system type Assembly Drawing Preparing for switch to Self-contained type PORT ADAPTOR GF118 (G 1/8) Fitting system type

M6

SP16

Self-contained type

(G 1/8, 7/16 PORT) 2.1 ~ 2.5 reference

Remove Port Adaptor from cylinder.

Self-contained type

Fitting system type

(M6 PORT) 1.1 ~ 1.5 reference

PLUG PORT ADAPTOR Removal Tool 1.G 1/8 7/16-20

Self-contained type (M6 PORT)

Fitting System type (G 1/8, 7/16 PORT)

Install valve by using Valve Tighten Tool.

5mm wrench 4mm wrench

VALVE CONTROL TOOL

VALVE TIGHTEN TOOL

M6 PORT ADAPTOR (SPANNER 10mm) 3.G 1/8 7/16 PORT ADAPTOR (SPANNER 16mm)

Install plug by using wrench.

Remove valve by using Valve Tighten Tool.

※ Task Note VALVE

1.4 Make sure there is no residual gas left in the inside of cylinder before opening the valve. Then, remove the valve using valve

PLUG GP118 (G 1/8) wrench 5mm

1.5 Make sure the O’ring places

VALVE TIGHTEN TOOL

inside of the port adaptor before

Install Port Adaptor on Cylinder. Now, Ready for fitting system PORT ADAPTOR CF111 (M6) SP10

inside of plug before installation

of cy linder.

SHINWEON S&T CO.,LTD.

Copyright ⓒ2010 by SHINWEON S&T CO.,LTD All Rights Reserved 22/03/2011

www.shinweon.com 88

installation of cylinder. Completing plug 1.4 Fasten the valve using valve combination. tighten tool by torque of 9.8kgfㆍ Now, ready for selfcm. contained type 1.4 Make sure the O’ring places

86 - www.eoc.de


NITROGEN GAS SPRING

TECHNICAL DATA

Technical Data

■ Calculation of Pressure Ratio

EX) What is the pressure ratio when 50mm of stroke is applied with EOC GAS SPRING TSS5000 x 60?

■ Calculation of Accumulator applied

F = Pressure Ratio Va = Volume of Accumulator(㎠) Vg = Volume of Gas Spring(㎠) n = Numbers of Gas Spring S = Real Used Stroke(㎝) R = Cross Section of piston Rod(㎠)

EX) What is pressure ratio when 50mm of stroke is applied with 12 of EOC GAS SPRING TSS 5000 x 60 and 2 of Accumulators TAN080-75?

■ Initial force gradient due to temperature

Volume increases as temperature increases, and volume decreases as temperature decreases. (PV = RT) With constant pressure volume of any gas increases 1/273 by increment of 1℃ from 0℃ of temperature (Charles’s Law). Initial temperature

Final temperature

Pressure is proportional to the force EX) At 20℃, what is force of gas spring if temperature of gas spring (initial force of 7,350N) is increased by 50℃ during operation?

22/03/2011

absolute (K) = ℃ + 273

www.eoc.de - 87


TECHNICAL DATA

NITROGEN GAS SPRING

Technical Data

■ Calculation of Pressure Ratio ※ Weight conversion of Nitrogen gas P = Pressure V = Volume n = Number of mol R = Ideal gas constant T = Absolute temperature

(Ideal gas equation)

※ Molecular weight of Nitrogen M = 28.0134 Volume of Nitrogen gas 1mol = 22.4 Liter

EX) When you apply fitting system with 6 of EOC GAS SPRING TSM1500 x 60 and 10 of TSM5000 x 80, what is amount of nitrogen gas to be charged? Specifications : Nitrogen gas charging pressure 120bar 35℃) Cyilnder Volume (40.1 Liter)

Standard : Volume of TSM1500 x 60 = 205.6 ㎤ Charging Pressure: 150 bar (20℃) Volume of TSM1500 x 80 = 675.1㎤

(Number of mol)

(Molecular Weight of Nitrogen)

(Number of mol)

(Molecular Weight of Nitrogen) (actually using gas)

Ex) When you apply fitting system with 6 of EOC GAS SPRING TSM1500 x 60 and 10 of TSM5000 x 80, what is amount of nitrogen gas to be charged?

(Number of mol)

(Molecular Weight of Nitrogen)

22/03/2011

= If amount of charge in fitting line and Panel and actual using gas are considered as 50%, 40.1 Liter bomb can use 1.4 times with each 7.98Liter.

88 - www.eoc.de


Info

Model

TSP Series

TSM Series

XTRA HIGH POWER

COMPACT TYPE

Ex.MODEL TSP1000 X 050

Ex.MODEL TSM0750 X 050

Stroke (mm)

Rod Φ(mm)

Cylinder Φ(mm)

Initial Force (N)

TSP0170 TSP0320 TSP0350 TSP0500 TSP0750 TSP1000 TSP1500 TSP2400 TSP4200 TSP6600 TSP9500

Model

Stroke (mm)

Initial Force (N)

TSL Series

TSS STANDARD

ISO STANDARD

Ex.MODEL TSS0750 X 050

Stroke (mm)

Rod Φ(mm)

Cylinder Φ(mm)

Ex.MODEL TSL0750 X 050

Initial Force (N)

Model

Stroke (mm)

Rod Φ(mm)

Cylinder Φ(mm)

Initial Force (N)

TSL0500 TSL0750 TSL1500 TSL3000 TSL50000 TSL75000 TSL10000

22/03/2011

TSS0750 TSS1500 TSS3000 TSS5000

Cylinder Φ(mm)

TSM0150 TSM0300 TSM0500 TSM0750 TSM1500 TSM3000 TSM5000

TSS Series

Model

Rod Φ(mm)

www.eoc.de - 89


90 - www.eoc.de


GENERAL CONDITIONS OF SALE DME EUROPE 1. CONCLUSION OF CONTRACT - APPLICATION The contract is validly entered into and the order is accepted after written confirmation by seller. These sales conditions apply to the exclusion of any other terms or conditions, unless expressly accepted in writing beforehand by the vendor. Seller has 30 (thirty) days since the reception of the order to accept or to refuse it. During this period, buyer shall not withdraw his order. Absence of any written confirmation of the order shall only be interpreted as being an implicit acceptance in case of performance of the order by seller. 2. PAYMENT Unless otherwise agreed in writing, invoices are payable in the stated currency within 30 (thirty) days after invoice date to the-bank designated by seller. Transfer charges are for account of buyer. If buyer does not pay within this term, seller shall automatically have ipso jure and without any prior formal notice, the right to charge legal interest plus 2 % from due date of the invoice. Moreover, in case of late payment, a fixed indemnity corresponding to 10 % of the payable amount shall automatically be due from the first day following the due date, without prejudice to seller’s right to prove higher damage and ask for corresponding indemnity. Should payment be in foreign currency, seller has the right to adapt the foreign currency in case of depreciation-of this foreign currency in regard of the euro. Should payment of the delivered goods be in instalments, the non-payment of one of the instalments gives seller the right to terminate the contract. The payments, which were done until then, shall remain property of seller as indemnity, without prejudice to the right to claim further damages or to the right to require the performance of the contract. Payment of advance shall not give buyer the right to terminate the contract upon reimbursement of the paid advance, If payment is done by bill of exchange or check, payment is deemed satisfied only when the bill of exchange or the check is honoured. Place of payment is always Mechelen even if payment is done with bill of exchange. 3. RETENTION OF TITLE Delivered goods remain property of seller until full payment has been received by seller. The sale of an unpaid item by buyer to a third party results in automatic assignment of the debt due by the third party to buyer, inclusively the retention of title, to seller. Seller has then the authority to take any necessary means in order to validly assign towards the third party. Seller may retake unpaid goods at any time and he may inform any client and/or any subcontractor of buyer about the fact that seller is and remains the only owner of the concerned goods until full payment. The purchaser undertakes to carefully keep the goods that have not been paid for, and undertakes not to pledge them or use them in any other way as a guarantee or security. The purchaser shall inform third parties who may apply any security rights over his assets (such as, but not limited to, the lessor of the premises occupied by the purchaser) that the products are and shall remain the property of the vendor until full payment of all sums owed by the purchaser to the vendor, and in the event of an attachment or other measures taken by third parties that apply to products for which full payment has not yet been made the purchaser undertakes to immediately inform the vendor of this to enable him to apply his rights. 4. RISKS Notwithstanding the preceding provisions, the risk transfers to buyer as soon as he has the goods at his disposal.

8. DELIVERY Date of delivery is the date when the goods are ready for inspection at the indicated place. Place of origin is Mechelen, Belgium, or any other place indicated by seller. Seller is not responsible for any late delivery, except those delays due to his own fault or gross negligence. 9. RETURNING OF GOODS No goods can be returned without seller’s previous, express and written consent. If buyer commits an error in ordering, the retaking of goods is possible only for inventory standard items. Goods must be returned within 15 (fifteen) days after invoice date and all goods must be in original conditions,’ all costs of transport are for buyer, as well as insurance and repacking costs. Special-order goods, marked or used items are non-returnable. 10. DEFECTS Seller warrants defects in material and/or workmanship. Warranty is limited to the replacement or repair, at seller’s option, of any merchandise found defective during 1 month. This warranty does not include defects due to buyer’s fault or to abnormal use, bad maintenance, imperfect installation, buyer’s inadequate repair, unforeseeable circumstances or in case changes were brought to material without previous and express written approval of seller. Notice of conspicuous defects must be given to seller by registered letter sent within 10 (ten) working days following date of delivery. Notice of hidden defects must be given to seller by registered letter with in 10 (ten) working days after date of discovery, and in any case, within a 10-month term following date of delivery. Seller is not responsible for any damage and in particular salary and material costs, losses, loss of profit or loss of a chance incurred by buyer, unless it is demonstrated that defect is due to seller’s gross or intentional fault. If seller is responsible for defect, seller has the right either to terminate the contract and to pay back all the invoiced prices or to replace the delivered product within a reasonable term. If goods for repair must be transported, costs and risks of this transport are for buyer. In case seller is responsible for any damage, this will be limited to the foreseeable damage with a maximum amount corresponding to the amount of the product’s invoiced price. Should a third party lodge a claim against seller to obtain payment of an indemnity for a damage for which seller is not responsible in accordance with the present conditions or for a higher amount than the one seller is responsible for, buyer will warrant seller against those claims. 11. DESCRIPTION Only product descriptions used in seller’s latest literature and correspondence with buyer, are binding for description of goods. Buyer is responsible for using items in conformity with all regulations, including but not limited to, the safety regulations in force at the place of use. 12. SPECIFIC ORDERS For the performance of a special work, the project signed by buyer is binding to the extent it has been accepted by seller. For the performance of such work, special conditions may be required. In case of any inconsistency between general conditions and special conditions, the special conditions shall apply. Should special conditions be unclear, they shall be interpreted in light of the general conditions.

5. DISPATCHING OF INSIGNIFICANT VALUE Each dispatch of less than € 50 will be increased with costs of payments andmay, at sellers option, be sent cash on delivery (COD).

13. ACT OF GOD Seller shall not pay any damage for non-performance or late performance of his undertakings due to Act of God. Act of God includes in particular and without being limited thereto, strike, lock-out, and the non-performance by seller’s suppliers of their undertakings.

6. PRICE OFFERS AND PRICE LISTS Price offers and price lists are without obligation and are subject to change without any previous notice. Any information released by seller is delivered in good faith and seller shall not be responsible for the choice of material and goods.

14. VALIDITY AND INDIVIDUAL CLAUSES If one or more provisions of these present general conditions are held to be invalid, the remaining provisions will continue to be valid and enforceable, and parties will agree upon other provisions having an economic effect that corresponds closest to the economic effect of the invalid provision(s).

7. PRICE AND DISPATCHING All prices are ex works. Transportation, duties and taxes for account of buyer, unless seller’s previous and express written specification to the contrary. Seller shall send goods by the fastest and most economic way at the risks of buyer. Goods may be insured by seller at buyer’s option, the insurance premiums are for buyer. Seller is not responsible for the choice of packing.

15. WAIVER In case seller does not exercise one of his rights in accordance with the present conditions, this shall not be interpreted as a waiver of these rights. 16. APPLICABLE LAW – COMPETENT COURTS This sales contract will be governed by Belgian law. The competent court is the Commercial Court of Mechelen, without prejudice to seller’s right to introduce the case before another competent court.


Š2010 DME Europe Industriepark Noord G1, B-2800 Mechelen , Belgium - Trade Register Mechelen, VAT BE 0456.932.455. All rights reserved. No part of this publication may be reproduced without the prior permission in writing of DME Europe. Content subject to change without prior notice. Terms and conditions of sale see www.dmeeu.com

Your contact: DME Europe Industriepark Noord G1 2800 Mechelen - Belgium Tel.: +32 15 21 50 11 Fax: +32 15 40 51 11 dme_europe@dmeeu.com

BE Tel. : +32 15 21 50 21 Fax : +32 15 40 51 21 dme_benelux@dmeeu.com CZ Tel.: 800 142 451 - 571 616 320 Fax: 800 142 450 - 571 611 996 dme_cz@dmeeu.com DE Tel. : +49 (0)2351 437 0 0800 664 82 50 - Toll free Fax : +49 (0)2351 437 220 0800 664 82 51 - Toll free dme_normalien@dmeeu.com

ES Tel.: 900 900 342 - Toll free Fax: 900 900 343 - Toll free expulsores_girona@dmeeu.com

NL Tel. : +31 (0)2065 45 571 Fax : +31 (0)2065 45 572 dme_benelux@dmeeu.com

RO Tel. : 0800 833 370 - Toll free Fax : 0800 833 371 - Toll free dme_export@dmeeu.com

Export Tel. : +32 15 21 50 17 Fax : +32 15 40 51 17 dme_export@dmeeu.com

PL Tel. : +800 331 1312 Fax : +800 331 1313 dme_polska@dmeeu.com

SK Tel.: 0800 142 451 +420 571 616 320 Fax: 0800 142 450 +420 571 611 996 dme_cz@dmeeu.com

FR Tel.: +33 1 49 93 92 23 Fax: +33 1 49 93 92 22 dme_france@dmeeu.com

PT Tel.: 800 207 900 - Toll free Fax: 800 207 901 - Toll free expulsores_girona@dmeeu.com

UK Tel.: +44 2071 3300 37 Fax: +44 2071 3300 36 dme_uk@dmeeu.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.