INFORMATION LEAFLET

Argo-naught 2010 Weld Gas Analyser

di

el

w

id

NEW unique design prevents accidental turning of calibration wheel NEW isolated, sealed battery and sensor compartment prevents damage to electronics in case of sensor or battery leakage NEW clear, large, angled display to allow easy readings of oxygen level NEW display turns off automatically to avoid draining of batteries

w

ap

.R

• • • •

w

• •

NEW hermetically sealed, robust housing NEW air and water-tight NEW ideal for wet and sandy conditions NEW no electronic emissions NEW state of the art electronics NEW very high measurement accuracy NEW extremely quick response time

w

n

SPECIAL FEATURES OF THE ARGO-NAUGHT 2010 WGA

• • • •

NEW NEW NEW NEW

increased sensor life expectancy easy and quick Jack plug push-in sensor change no loose wires during sensor change very cost-effective maintenance

Manufactured in the UK to ISO standards

Weldwide Solutions Limited Information Leaflet Argo-naught 2010 Weld Gas Analyser

1


m

GENERAL

g.

co

The Argo-naught 2010 Weld Gas Analyser accurately monitors oxygen levels while fabricators use inert gas to purge stainless steel, titanium and other reactive metal pipework and vessels before and during welding. The Argo-naught 2010 Weld Gas Analyser allows continuous measurements of the oxygen content in the vicinity of the weld down to 0.1% (1000 ppm).

el

di

n

Correct use of the Weld Gas Analyser allows customers to determine when the safe level for welding has been reached, thus eliminating any guess work. It helps save on argon gas consumption, since some welders might purge much longer than is actually required by playing it safe. Therefore, the use of the Weld Gas Analyser helps lower the customer’s carbon footprint and will increase the welder’s production rate. It also helps to save on argon gas and enables fabricators to maintain or quicken work schedules that can increase profitability

w

throughout welding contracts.

w

.R

ap

id

The Argo-naught 2010 Weld Gas Analyser should be continually used during welding to monitor the weld purge levels. It will quickly identify any oxygen level drawn into the pipe volume that is being shielded with inert gas. Typically, customers choosing to purge pipes with gaps between the pipe end bevels, will tape up the gap prior to welding when they purge. If the gas flow is too low, argon will escape from the purge allowing atmosphere and oxygen through the weld gap once fabricators begin to remove the tape. The Argo-naught 2010 Weld Gas Analyser will save the weld root by showing the fabricator if the levels rise to an unacceptable level.

w

OPERATION OF THE ARGO-NAUGHT 2010 WELD GAS ANALYSER

w

The small size and battery operation of the Argo-naught 2010 Weld Gas Analyser makes it easily portable and ideal for monitoring oxygen levels for welding on-site. It is supplied with a stainless steel probe, a 2 metre rubber tube, a rubber vacuum bulb, operating instructions and calibration and test certificates. The rubber tube of the Argo-naught 2010 Weld Gas Analyser can be connected directly to the weld purge system or purge dam through the exhaust port of the purging device. Alternatively, the stainless steel probe can be inserted through the weld gap or the exhaust of the weld purging system. Once the Argo-naught 2010 Weld Gas Analyser is in place, the rubber bulb is activated to transport a sample of the atmosphere in the vicinity of the weld to the sensor of the instrument. The sensor accurately measures the oxygen content of the sample and displays the oxygen level on the easily readable LCD display. Welding can begin as soon as satisfactory oxygen levels are reached. Weldwide Solutions Limited Information Leaflet Argo-naught 2010 Weld Gas Analyser

2


g.

co

m

Weldwide Solutions Limited recommends the use of inflatable pipe purging dams and Silicone disc purging systems when customers are welding schedule pipework and all other kinds of cylindrical vessels. These products compliment the Argo-naught 2010 Weld Gas Analyser and, used together, they will help to eliminate all oxidised weld roots in stainless steel and other exotics.

di

n

SPECIFICATION OF THE ARGO-NAUGHT 2010 WELD GAS ANALYSER 0 % to 100 % oxygen

Accuracy

+/- 1 % of the full scale +/- 0.1 %

Battery Requirements Sensor life in air

.R

Dimensions

ap

Sensor type

id

Resolution

in less than 10 seconds

w

Response time to 90 % step change

Weight

el

Range

2x MN1500 LR6 1.5V (AA) Galvanic, Jack plug push-in 36-48 months (typically longer in lower oxygen environments) 60 mm x 120 mm x 35 mm 198 gms including sensor and batteries 0-50°C (recommended 10-30°C)

Operating temperature

0-40°C

Case

splash-proof, hermetically sealed

ISO standards

ISO EN 9001:2000 ISO EN 60601-1:2006

EMC

ISO EN 60601-1-2

RoHs

Complies with the RoHs directive

WEEE

Complies with the WEEE directive

w

w

w

Storage temperature

Weldwide Solutions Limited Information Leaflet Argo-naught 2010 Weld Gas Analyser

3


co

id

ap

w

el

g.

n

• • •

air and water-tight due to hermetically sealed, robust housing Ideal for wet and sandy conditions No electronic emissions Increased sensor life expectancy due to decreased contamination State of the art electronics allow very high measurement accuracy and extremely quick response time to changes in oxygen levels The unique design prevents the accidental turning of the calibration wheel during handling, which will falsify the reading Easy and quick sensor change due to push-in mechanism Very cost-effective maintenance (replacement sensors, calibration) sealed battery and sensor compartment prevents damage to electronics in case of sensor or battery leakage

di

m

ADVANTAGES OF USING THE ARGO-NAUGHT 2010 WELD GAS ANALYSER

Manufactured in the UK to ISO standards RoHS and WEEE compliant

• • •

Quick responses to oxygen levels whilst purging Identifies when it is safe to start welding Warns fabricators to stop welding when their purging technique allows air into the volume being shielded with inert gas Cuts down on inert shielding gas required Helps reduce customers’ carbon foot print Repeatedly allows customers to increase weld production rates Reliably eliminates weld defects associated with purging Helps achieve a uniform weld profile

w

w

w

• • • • •

.R

• •

Contact us Telephone: +44 (0)1554 700 350 Email: darren@weldwidesolutions.com Fax: +44 (0)1554 754 276 http://www.weldwidesolutions.com Weldwide Solutions Limited Information Leaflet Argo-naught 2010 Weld Gas Analyser

4


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.