Over 85 of electro-installation and stowage material production The beginning of electrotechnic production of KOPOS KOLÍN goes back to the year 1926. Even before the WWII the company reached monopolistic status among keen competition on domestic market. After war the assortment changed slightly to match political needs. Starting from 1994, new management of the company started with intense investments and development program. To ensure enough of quality raw material, the company has built its own PVC mixture production facility. The peak of the modernization process with regards to the quick growth of the company and its high logistics demands occurred in the year of 2005 and in 2009 there were opened two new storage and administrative production halls. Within the innovation processes the company progressively introduces a new way of producing the technical documentation and a lot of modern technologies. A lot of new products were introduced, e.g. series of electroinstallation laths, double-coated corrugated pipes, double-coated parapet culverts, lead-free products or wide range of halogen-free products. There are 7000 kinds of products up today in the assortment of KOPOS KOLÍN. The company’s number one production priority is the quality of products. New products are always adjusted to match the EU standard requirements and all the assortment is traditionally tested according requirements of harmonized electrotechnic standards. KOPOS KOLÍN a.s. is a holder of the certificate ISO 9001 and ISO 14001 as well as the Safe company and the Czech quality certificates. The company provides 100% guarantee on keeping the process stability, and consequently on the quality and safety of the products. The company is always ready to match increased needs of the market and this helps to keep its permanent leading position. It can be considered a significant success that in the recent years KOPOS KOLÍN a.s. opened up 13 daughter sales companies mainly in Easter Europe, Central America but also in Asia and in Africa, and it evolved from a domestic supplier to a company with a share in the world’s market. The most important man in KOPOS KOLÍN is always the customer. THANK YOU FOR YOUR PARTNERSHIP
JUNCTION BOXES AND ACCESSORIES
1
WIRING TRUNKINGS AND ACCESSORIES
2
WIRING PIPES AND ACCESSORIES
3
F I X I N G M AT E R I A L
4
T E C H N I C A L I N F O R M AT I O N
5
WIRING BOXES AND ACCESSORIES
1
Junction boxes and accessories In compliance with the standard ČSN EN 60 670-1 - Boxes and covers for electric accessories for house and other similar fixed electrical installations. Under parget ............................................................................................................................................................................................................................................... 1-4 Material: Hard self-snuffing polyvinylchloride (PVC) with temperature resistance from -5 °C to +60 °C. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 850 °C. KOPOS KOLÍN a.s. as the manufacturer recommends installing the boxes on and into construction materials with fire classes A1 to D according to ČSN EN 13501-1. Krabice jsou určené pro rozvody s napětím 400 V and s proudem max 16 A. The boxes are designed for distribution system with voltage 400 V and with maximum current 16 A. A basic color of boxes under plaster is light grey. Boxes can be also produced in different colors. Into thermal insulation ............................................................................................................................................................................................................................. 1-17 Material: self-snuffing halogen-free polypropylene (PP) with temperature resistance from -25 °C to +60 °C. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 850 °C. KOPOS KOLÍN a.s. as the manufacturer recommends installing the boxes on and into construction materials with fire classes A1 to F according to ČSN EN 13501-1. The boxes are designed for distribution system with voltage 400 V. Into hollow walls ....................................................................................................................................................................................................................................... 1-19 Material: Hard self-snuffing polyvinylchloride (PVC) with temperature resistance from -5 °C to +60 °C. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 850 °C. KOPOS KOLÍN a.s. as the manufacturer recommends installing the boxes on and into construction materials with fire classes A1 to F according to ČSN EN 13501-1. The boxes are designed for distribution system with voltage 400 V and with maximum current 16 A. The KOPOS KOLÍN company, as the manufacturer, recommends using the KI 68 L/1 box and its modification for installation into construction materials with class and to C3 in compliance with the formerly valid standard ČSN 73 0862. For all the products in the product line for hollow walls, we recommend using set of cutters supplied by us, see page 1-71 - 1-72.
J U N C T I O N B O X E S
Trunking boxes ......................................................................................................................................................................................................................................... 1-30 Material: Hard self-snuffing polyvinylchloride (PVC) with temperature resistance from -5 °C to +60 °C. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 850 °C. KOPOS KOLÍN a.s. as the manufacturer recommends installing the boxes on and into construction materials with fire classes A1 to C according to ČSN EN 13501-1. The boxes are designed for distribution system with voltage 400 V and with maximum current 16 A. In combination with heat-insulating pad (see page 1-67) with thickness of 5 mm made of material with reaction to fire class A1 - F the installation on flammable surfaces may be carried out without any limitation. Closed boxes – plastic (IP 40, 54, 65, 66) ................................................................................................................................................................................................ 1-38 Material: Hard self-snuffing polyvinylchloride (PVC) with temperature resistance from -5 °C to +60 °C is used for boxes 8101 - 8119. Self-snuffing polypropylene (PP) and polyethylene (PE) with temperature resistance from -5 °C to +60 °C is used for boxes 8130 and 8135. Flame retardant polypropylene (PP) and polycarbonate (PC) with temperature resistance from -25 to +60°C is used for KSK series boxes. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 650 °C (850°C for KSK series boxes). KOPOS KOLÍN as the manufacturer recommends installing boxes (except the types 003.CS.K and 005.CS.K) on and into construction materials with fire classes A1 to C or D according to ČSN EN 13501-1. In combination with 5 mm heat-insulating pad, the installation on construction materials can be carried out without fire class A1 - F limitation. In the case of installation on construction materials with fire class A2 to C or D according to EN 13 501-1, they are designed for wiring with voltage of 400 V and a current of max 16 A. In the case of installation on construction materials with reaction to fire class A1 or with heat-insulating pad, they are designed for distribution system with voltage 500 V. The 003.CS.K and 005.CS.K type boxes may be used only on construction materials with reaction to fire class A1. Closed boxes – metal (IP 54) .................................................................................................................................................................................................................... 1-49 Material: Al-alloy suitable for installation on construction materials with reaction to fire class A1 to C or D (see page 5-3). In combination with heat-insulating non-flammable pad with thickness of 5 mm made of material with reaction to fire class A1, the installation on construction materials may be carried out without any limitation. Halogen-free (HF) ..................................................................................................................................................................................................................................... 1-53 Material: PC, PPO – is self-snuffing with temperature resistance from -45 °C to +105 °C. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 850 °C. KOPOS KOLÍN a.s. as the manufacturer recommends installing the boxes on and into construction materials with fire classes A1 to F according to ČSN EN 13501-1 (This classification applies to KU 68 LD/1HF and KP 64/LD HF boxes). For other halogen-free junction box, the manufacturer recommends mounting on and in construction materials with fire class A1 to C or D according to ČSN EN 13 501-1. The boxes are designed for distribution system with voltage 400 V and with maximum current 16 A. In combination with heat-insulating non-flammable pad with thickness of 5 mm made of material (see page 1-67) over the whole contact surface, or with heat-insulating bed, the installation on construction materials may be carried out without any limitation. The material is resistant to flame propagation and is halogen free. It is used for environment with higher concern over public and health protection. Compared to commonly manufactured types, the junction distribution boxes differ only in used material, which is marked with the HF letters at the end of the type code. Accessories .............................................................................................................................................................................................................................................. 1-59 Terminal plates ......................................................................................................................................................................................................................................... 1-68 Terminal plates are resistant to excessive heat and burning in compliance with ČSN EN 60 998-1:97 and ČSN EN 60 998-2-1:97, and passed the flaming loop test 850 °C. Help tools and utilities .............................................................................................................................................................................................................................. 1-71 Multi-purpose box KOPOBOX mini ........................................................................................................................................................................................................ 1-73 Material: self-snuffing PC-ABS of temperature resistance from -5 till +60°C The system of KOPOBOX mini boxes conforms to the requirements of ČSN EN 60 670-1, Art.. 18 and it conforms to the proof Test against excessive heat and burning by glowing loop of temperature 850 °C. KOPOS KOLÍN a.s. as the manufacturer recommends the assembling of those boxes on/to building materials of Class Reaction to Fire A1 till F in accordance to ČSN EN 13 501-1. The Boxes are intended for distributions of max. voltage of 500 V. The material is resistant against spread of flame and doesn’t contain halogens. The Boxes can be used at environment of higher interest for protection of persons and equipment. Into concrete floors .................................................................................................................................................................................................................................. 1-77 Material: Halogen-free, self-snuffing polyamide (PA) with temperature resistance from -30 °C to +105 °C and polyethylene (PE) with temperature resistance from -30 °C to +70 °C. According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 850 °C. Sets are designed for use in cast concrete floors. The boxes are designed for distribution system with voltage 500 V.
2
Junction boxes and accessories
1
For embedding into poured concrete ..................................................................................................................................................................................................... 1-84 Material: Halogen-free polyethylene (PE) with temperature resistance from -30 °C to +70°C (90 °C for and short term), halogen-free polypropylene (PP) with temperature resistance from -25 °C to +105 °C, halogen-free polyamide (PA) with temperature resistance from -30 °C to +105 °C (120 °C for and short term). According to the requirements of ČSN EN 60 670-1 § 18, the boxes comply with the excessive-heat resistance test as well as the test with flaming loop with temperature 650 °C. This assembly is designed for concrete constructions; used polyethylene is not self-snuffing. The boxes are designed for distribution system with voltage 400 V.
KSK series boxes - p. 1-38
J U N C T I O N All boxes, accessories (except PI 80....) and terminal plates are in compliance with EU directions.
Icons - capture material
functionality during and fire
temperature resistance, scope of application (°C)
lenght (mm)
flaming loop test (°C)
halogen-free material
fire class
dimensions – width, height, depth (mm)
self-snuffing
number of conductors x diameter (mm2), load-current capacity: (A)
spacing when joining two boxes (mm)
milled (drilled) hole diameter (mm)
allows to install double-socket
package (pcs)
products manufactured from leadless material
accessories, additional assortment
level of protection - IP classification
auxiliary tools
B O X E S
3
1
KU 68-1901
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KU 68-1901
J U N C T I O N B O X E S u n d e r
KA
boxes loose in cardboard, device screws not placed in boxes
100
8595057600096
ZB
boxes packed in packs of 10 pieces in shrink film, device screws included in the package
10; 80
8595057619265
SN
two boxes fitted with blanking cap, 4 device screws included - packed in shrink film
2; 100
8595057687974
Possibility to join into and continuous series with and spacing of 71 mm. Connection of up to three boxes in and row is recommended. Boxes can be joined with boxes KP 68/2, KP 68 and KPR 68. Possibility to insert a terminal plate and screwless terminals. Sold in packs (2; 10; 100 pcs).
- accessories
- auxiliary tools
KO 68 pg. 1-59
KU 68-1902
ZV 68 pg. 1-62
S-66 pg. 1-68
TYP0... pg. 1-70
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KU 68-1902
p a r g e t
KA
boxes loose in cardboard fitted with a cap
100
To create path branches. Sold in packs (100 pcs). Easy-to-install lid, even without tools.
- accessories
ZV 68 pg. 1-62
4
FR 68 SDS ∅ 80 mm pg. 1-72
- auxiliary tools
S-66 pg. 1-68
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
package
8595057600195
KU 68-1903
1
- junction box
PVC
-5 - +60°C
850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
KU 68-1903
KA
boxes loose in cardboard fitted with a cap and a terminal plate
8595057600287
Clearly arranged installation. High quality connection of electrical potentials using screws. Brass PE terminal.
- accessories
ZV 68 pg. 1-62
KP 67/2
100
J U N C T I O N
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71/81
conf.
description
EAN pcs
KP 67/2
KA
boxes loose in cardboard, device screws not placed in boxes
90
8595057615496
ST
each box fitted with an EAN label, device screws fitted in the box
90
8595057699427
For modern installations in combined frames. Vertical and horizontal connection with a spacing of 71 or 81 mm. Possibility to connect 5 boxes in a series. Possibility to increase axial distance with a spacer for the design lines Element, Neo. Sold in packs.
B O X E S u n d e r p a r g e t
- accessories
V 68 pg. 1-60
DR18 pg. 1-65
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
package
5
1
KP 67/3
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 67/3
boxes loose in cardboard, device screws not placed in boxes
8595057650558
Suitable for 2x double frames. When using the DR18 spacers, boxes are suitable for devices with larger widths, such as Neo .... Sold in packs (100 pcs).
- accessories
DR18 pg. 1-65
V 68 pg. 1-60
KP 68/2
TYP0... pg. 1-70
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 68/2
p a r g e t
KA
boxes loose in cardboard, device screws not placed in boxes
ZB
boxes packed in packs of 10 pieces in shrink film, device screws not fitted in the boxes
150
8595057600089
10; 120
8595057619272
Possibility to join into and continuous series with and spacing of 71 mm. Connection of up to three boxes in and row is recommended. Boxes can be joined with boxes KU 68-1901, KP 68 and KPR 68. Allows the installation of wiring in thin partitions. Sold in packs (10; 150 pcs).
- accessories
V 68 pg. 1-60
6
100
Possibility to connect up to 5 boxes vertically and horizontally.
J U N C T I O N B O X E S u n d e r
KA
- auxiliary tools
ZV 68 pg. 1-62
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
package
KP 68
1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 68
KA
boxes loose in cardboard, device screws not placed in boxes
100
Possibility to join into and continuous series with and spacing of 71 mm. Connection of up to three boxes in and row is recommended. Boxes can be joined with boxes KU 68-1901, KP 68/2 and KPR 68. Universal box for most devices. Sold in packs (100 pcs).
- accessories
J U N C T I O N
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
ZV 68 pg. 1-62
V 68 pg. 1-60
KPR 68
8595568910592
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KPR 68
KA
packed in packs of 10 pieces in shrink film, packs aligned in cardboard
10; 100
Easy installation of devices with big depth.
p a r g e t
Possibility to join into and continuous series with and spacing of 71 mm. Connection of up to three boxes in and row is recommended. Possibility to easily clamp under the device using screwless terminals. Boxes can be joined with boxes KU 68-1901, KP 68/2 and KP 68. Sold in the smallest complete packages (10 pcs).
- accessories
V 68 pg. 1-60
8595057648302
B O X E S u n d e r
- auxiliary tools
ZV 68 pg. 1-62
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
package
7
1
KP 64/2
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 64/2
two boxes packed in shrink foil and covered with label, device screws included in the bag, packs placed in cardboard
Sold in the smallest complete packages (2 pcs).
VKP 64/2L pg. 1-61
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 64/3
p a r g e t
KA
two boxes packed in shrink foil and covered with label, device screws included in the bag, packs placed in cardboard
2; 32
For modern installations in combined frames. Significant rigidity makes device installation easier. Sold in the smallest complete packages (2 pcs).
- accessories
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
8
8595057632707
Significant rigidity makes device installation easier.
- accessories
KP 64/3
2; 50
For modern installations in combined frames.
J U N C T I O N B O X E S u n d e r
KA
material
temperature resistance
self-snuffing
fire class
flaming loop test
spacing when joining boxes
package
8595057632714
KP 64/4
1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 64/4
KA
two boxes packed in shrink foil and covered with label, device screws included in the bag, packs placed in cardboard
8595057632721
For modern installations in combined frames. Significant rigidity makes device installation easier. Sold in the smallest complete packages (2 pcs).
- accessories
J U N C T I O N
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
KP 64/5
2; 28
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 64/5
KA
two boxes packed in shrink foil and covered with label, device screws included in the bag, packs placed in cardboard
2; 16
8595057657212
B O X E S u n d e r p a r g e t
For modern installations in combined frames. Significant rigidity makes device installation easier. Sold in the smallest complete packages (2 pcs).
- accessories
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
fire class
flaming loop test
spacing when joining boxes
package
9
1
KP 67X67
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
71
conf.
description
EAN pcs
KP 67X67
boxes loose in cardboard, device screws not placed in boxes
8595057600072
Suitable for 2x double frames. Square shape increases the mounting volume of the box. Spacer for a spacing of 83 mm.
- accessories
TYP0... pg. 1-70
DR42 pg. 1-65
KUH 1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KUH 1
p a r g e t
KA
boxes packed individually in shrink film, installation screws included
More space in the box allows the insertion of active elements under the device. Possibility to insert the terminal S-66 directly under the device. Suitable for modern electrical system with higher space requirements.
- accessories
V 68 pg. 1-60
10
100
Possibility to connect up to 5 boxes vertically and horizontally.
J U N C T I O N B O X E S u n d e r
KA
S-66 pg. 1-68
ZV 68 pg. 1-62
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
package
1; 35
8595057688445
KO 97/5
1
- junction box with cover KO 97 V
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KO 97/5
KA
boxes with attached lids placed in a cardboard separately
90
8595057600164
A large number of knockouts to make larger installations. Projections against ripping the box out of the wall. Sufficient space for terminal plate and circuit connection.
J U N C T I O N
- accessories
S-96 pg. 1-68
ZV 97 pg. 1-62
KR 97/5
TYP0... pg. 1-70
SP-96 pg. 1-68
- junction box with cover KO 97 V and terminal plate SP-96
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KR 97/5
KA
terminal plate SP-96 screwed into the box, lids included and each box placed into cardboard
A large number of knockouts to make larger installations. Projections against ripping the box out of the wall. Sufficient space for terminal plate and circuit connection.
80
8595057600256
B O X E S u n d e r p a r g e t
- accessories
ZV 97 pg. 1-62
S-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
TYP0... pg. 1-70
11
1
KOM 97
- junction box with cover KO 97 V
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KOM 97
boxes with attached lids placed in a cardboard separately
8595057632752
Projections against ripping the box out of the wall. Sufficient space for terminal plate and circuit connection.
- accessories
KO 100
SP-96 pg. 1-68
S-96 pg. 1-68
ZV 97 pg. 1-62
TYP0... pg. 1-70
- junction box with cover
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KO 100
p a r g e t
KA
individual boxes and lids packed in cardboard
A large number of knockouts for introducing cables and pipes.
- accessories
S-66 pg. 1-68
12
40
A large number of knockouts to make larger installations.
J U N C T I O N B O X E S u n d e r
KA
S-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
SP-96 pg. 1-68
TYP0... pg. 1-70
74
8595057600133
KO 100 E
1
- junction box with cover V 100 E
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KO 100 E
KA
individual boxes and lid packings placed in cardboard
40
8595057612655
A large number of knockouts for introducing cables and pipes. Possibility to install the support trunking TS 35. Possibility to set the lid in a horizontal position. Possibility to break the sidewall for easier cable handling.
J U N C T I O N
- accessories
KO 125
SP-96 pg. 1-68
S-96 pg. 1-68
S-66 pg. 1-68
EPS 3 pg. 1-70
TYP0... pg. 1-70
TS35 pg. 2-46
- junction box with cover KO 125 V
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KO 125
KA
each box packed individually in shrink foil and labelled
1; 34
A large number of knockouts for introducing cables and pipes.
8595057600140
B O X E S u n d e r p a r g e t
Possibility to install the support trunking TS 35 and terminal plates.
- accessories
S-66 pg. 1-68
S-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
SP-96 pg. 1-68
EPS 3 pg. 1-70
TYP0... pg. 1-70
TS35 pg. 2-46
13
1
KO 125 E
- junction box with cover V 125/1
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KO 125 E
1; 20
8595057612587
Possibility to install the support trunking TS 35. Possibility to set the lid in a horizontal position. Possibility to break the sidewall for easier cable handling.
- accessories
SP-96 pg. 1-68
S-96 pg. 1-68
S-66 pg. 1-68
EPS 2 pg. 1-70
TYP0... pg. 1-70
TS35 pg. 2-46
KO 125 E/EQ02 - junction box with equipotential terminal
PVC
-5 - +60°C
850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
KO 125 E/EQ02
p a r g e t
14
each box packed individually in shrink foil and labelled
A large number of knockouts for introducing cables and pipes.
J U N C T I O N B O X E S u n d e r
KA
KA
each box packed individually in shrink foil and labelled
Equipotential terminal plates for 5 wires of 25 mm and 1 flat wire of 30x4 mm. A large number of knockouts for introducing cables and pipes. Possibility to set the lid in a horizontal position. Possibility to break the sidewall for easier cable handling.
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
1; 20
8595568909169
KT 250
1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KT 250
KB
individual boxes packed in shrink foil, labelled and placed in cardboard
1; 11
8595057600294
Boxes for communication and power distribution. At the bottom of the box are grooves for mounting the telephone terminals. Suitable for surface mounting - lid follows the size of the box. Boxes without preformed knockouts.
J U N C T I O N
- accessories
S-96 pg. 1-68
S-66 pg. 1-68
KT 250/1
SP-96 pg. 1-68
TYP0... pg. 1-70
TS35 pg. 2-46
- junction box with cover VKT 250/L
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
KT 250/1
KB
individual boxes packed in shrink foil, labelled and placed in cardboard
1; 12
A large number of knockouts for introducing cables and pipes.
8595057632738
B O X E S u n d e r p a r g e t
Possibility to install support trunking TS 35 and equipotential terminal plate. Option to set the lid using oval holes in the box to the horizontal position. Possibility to break the sidewall for easier cable handling.
- accessories
S-66 pg. 1-68
S-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
SP-96 pg. 1-68
EPS 2 pg. 1-70
TYP0... pg. 1-70
TS35 pg. 2-46
15
1
KT 250X110
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
IP30
conf.
description
EAN pcs
KT 250X110
HB
boxes packed individually in shrink film
8595057600300
Designed for internal communication and power distribution wiring for surface mounting. Color - white. Flat bottom allows installation of specific equipment.
J U N C T I O N
- accessories
S-66 pg. 1-68
B O X E S u n d e r
S-96 pg. 1-68
SP-96 pg. 1-68
TYP0... pg. 1-70
TS35 pg. 2-46
KOPOBOX mini B Configuration of multi-purpose mounting box for modular equipment to be suitable for mounting under the parget. More in pg. 1-74
p a r g e t
16
1
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
package
KEZ
1
- installation box into thermal insulation
PP
-25 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KEZ
KB
individual boxes packed in separate cardboard
1
8595057698499
For device installation in insulated building fasades with a thickness from 50 - 200 mm. Eliminates thermal bridging.
Included in the packaging are high quality wall plugs and screws for mounting; when installing into rough plaster, we recommend to seal the device with silicon.
Robust construction.
* see assembly video at www.kopos.com
J U N C T I O N B O X E S i n t o
KEZ-3
- multiple electroinstallation box into thermal insulation
PP
-25 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
KEZ-3
KB
individual boxes packed in separate cardboard
1
For device installation in insulated building fasades with a thickness from 100 - 250 mm.
8595568910561
t h e r m a l
Eliminates thermal bridging. The package includes quality wall plugs, screws for mounting and a partition to separate multiple circuits. When installing on a rough surface, we recommend to seal the device with silicone. Robust construction.
* see assembly video at www.kopos.com
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
low halogen material
i n s u l a t i o n
package
17
1
MDZ
- mounting desk into thermal insulation
PP
-25 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
MDZ
KB
individual mounting plates are packed in separate cardboard
8595057698505
For the installation of electrical devices (outdoor lights, motion sensors, 400 V sockets, etc.) on thermally insulated buildings fasades with a thickness from 50 to 200 mm.
J U N C T I O N
Eliminates thermal bridging. Load of 40 N at a distance of 180 mm from the wall. Possibility to create areas of any size when using multiple mounting plates. The package includes quality wall plugs and screws for mounting. Robust construction.
* see assembly video at www.kopos.com
B O X E S i n t o
Assembling system into thermal insulation KEZ - installation box into thermal insulation
t h e r m a l
MDZ - mounting desk into thermal insulation
50 - 200 mm 50 - 200 mm
i n s u l a t i o n
max. 180 mm
KEZ-3 - multiple electroinstallation box into thermal insulation
There is necessary to cut the carrier including inserted insulation before installation depending on layer thickness insulation. The carrier is fixed to the wall with twists and dowels depending on type of the wall surface. For installation of 400 V plug we recommend to fasten the carrier with chemical anchors. The finally installation of box or mounting plate should be done by 4 added screws.
18
1
material
temperature resistance
self-snuffing
low halogen material
fire class
flaming loop test
for mounting and double-socket
package
max. 40 N
KU 68/71L1
1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
KU 68/71L1
boxes fitted with screws for mounting into double wall, device screws packed separately
NA
8595057688414
Connection in a continuous series with axial distance of 71 mm. Possibility to connect 3 boxes in a series. Integrated tip to mark the centre of drilling.
J U N C T I O N
Jointed boxes can be interconnected using single insulated wires. Connectible with the box KPR 68/71L. Mounting screws are fitted with a triple thread for quick installation. When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
- auxiliary tools
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
S-66 pg. 1-68
V 68 pg. 1-60
KU 68 LD/1
120
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KU 68 LD/1
NA
boxes fitted with screws for mounting into double wall, device screws are fitted in boxes
90
8595568905093
Inlet openings made of flexible material. Air-tightness even with inserted cable or pipe. Suitable for low energy and passive houses.
B O X E S i n t o d o u b l e
Mounting screws are fitted with a triple thread for quick installation. Prevents airflow through the installation. Sold in complete packages (90 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
V 68 pg. 1-60
- auxiliary tools
S-66 pg. 1-68
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
leadless material
w a l l s
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
package
19
1
KU 68 LD/2
- junction box with cover V 68
PVC
-5 - +60°C
850°C
item
A1 - F
30 sec.
IP30
conf.
description
EAN pcs
KU 68 LD/2
J U N C T I O N B O X E S i n t o
boxes fitted with screws for mounting into double wall, lid screwed on the box
8595568905109
Air-tightness even with inserted cable or pipe. Suitable for low energy and passive houses. Mounting screws are fitted with a triple thread for quick installation. Prevents airflow through the installation. Sold in complete packages (90 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- auxiliary tools
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
S-66 pg. 1-68
KPR 68/L
90
Inlet openings made of flexible material.
- accessories
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
- junction box
PVC
d o u b l e
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KPR 68/L
w a l l s
NA
individual boxes fitted with screws for mounting into double wall
56
8595057617179
Easy installation of devices with big depth. Possibility to easily clamp under the device using screwless terminals or terminal plate. Robust construction. Mounting screws are fitted with a triple thread for quick installation. Sold in complete packages (56 pcs). During the assembling there is necessary to dimple the edge of plasterboard.
- accessories
V 68 pg. 1-60
20
NA
- auxiliary tools
S-66 pg. 1-68
VDS 68 + ZBU ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
leadless material
fire class
flaming loop test
for mounting and double-socket
IP classification
package
VPTU; VPT 68; P1, ZBU ∅ 73,5 mm pg. 1-71
KPR 68/71L
1
- junction box
PVC
-5 - +60°C
850°C
item
A1 - F
30 sec.
71
conf.
description
EAN pcs
KPR 68/71L
NA
individual boxes fitted with screws for mounting into double wall
8595057687929
Easy installation of devices with big depth. Possibility to join into a continuous series with a spacing of 71 mm. Possibility to insert terminal S-66. Tips for marking hole centres for installation holes in the double wall.
J U N C T I O N
Jointed boxes can be interconnected using single insulated wires. Mounting screws are fitted with a triple thread for quick installation. Sold in complete packages. When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
- auxiliary tools
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
S-66 pg. 1-68
V 68 pg. 1-60
KI 68 L/1
60
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
- junction box
PVC
-5 - +60°C
item
850°C
A - C3
30 sec.
conf.
description
EAN pcs
KI 68 L/1
NA
individual boxes fitted with screws for mounting into double wall
80
8595057600119
According to the formerly valid standard ČSN 73 0862 the box complies with materials of fire classes A - C3. Special added outer housing. Mounting screws are fitted with a triple thread for quick installation.
- accessories
V 68 pg. 1-60
- auxiliary tools
S-66 pg. 1-68
B O X E S i n t o d o u b l e w a l l s
VPTU; VPT 79; P1 ∅ 79,5 mm pg. 1-71
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
leadless material
package
21
1
KP 64/LD
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KP 64/LD
J U N C T I O N B O X E S i n t o
boxes fitted with screws for mounting the box to double wall, device screws are fitted in boxes
8595568909305
Air-tightness even with inserted cable or pipe. Suitable for low energy and passive houses. Mounting screws are fitted with a triple thread for quick installation. Prevents airflow through the installation. Sold in complete packages (100 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- auxiliary tools
VPTU; VPT 64; P1 ∅ 68 mm pg. 1-71
TYP0... pg. 1-70
V 68 pg. 1-60
KP 64/2L
100
Inlet openings made of flexible material.
- accessories
- junction box
PVC
d o u b l e
-5 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
NA
two boxes packed in shrink foil and covered with label, screws included in the bag, packs aligned in cardboard
2; 50
8595057600058
ST
individual boxes fitted with screws for mounting into double wall and covered with label, device screws are fitted in boxes
50
8595057699403
KP 64/2L
w a l l s
For modern installations in combined frames. Significant rigidity makes device installation easier. Tips for marking hole centres for installation holes in the double wall. Mounting screws are fitted with a triple thread for quick installation. Sold in the smallest complete packages (2 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
VKP 64/2L pg. 1-61
22
NA
- auxiliary tools
VPTU; VPT 64; P1 ∅ 68 mm pg. 1-71
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
leadless material
fire class
flaming loop test
spacing when joining boxes
package
KP 64/3L
1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
NA
two boxes packed in shrink foil and covered with label, screws included in the bag, packs aligned in cardboard
2; 36
8595057611696
ST
individual boxes fitted with screws for mounting into double wall and covered with label, device screws are fitted in boxes
32
8595057699410
KP 64/3L
For modern installations in combined frames. Significant rigidity makes device installation easier.
Mounting screws are fitted with a triple thread for quick installation. Sold in the smallest complete packages (2 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
- auxiliary tools
B O X E S i n t o
VPTU; VPT 64; P1 ∅ 68 mm pg. 1-71
TYP0... pg. 1-70
KP 64/4L
J U N C T I O N
Tips for marking hole centres for installation holes in the double wall.
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
NA
two boxes packed in shrink foil and covered with label, screws included in the bag, packs aligned in cardboard
2; 28
8595057632776
ST
individual boxes fitted with screws for mounting into double wall and covered with label, device screws are fitted in boxes
28
8595568903624
KP 64/4L
For modern installations in combined frames.
d o u b l e
Significant rigidity makes device installation easier. Tips for marking hole centres for installation holes in the double wall. Mounting screws are fitted with a triple thread for quick installation. Sold in the smallest complete packages (2 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
- auxiliary tools
w a l l s
VPTU; VPT 64; P1 ∅ 68 mm pg. 1-71
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
leadless material
fire class
flaming loop test
spacing when joining boxes
package
23
1
KP 64/5L
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
NA
two boxes packed in shrink foil and covered with label, screws included in the bag, packs aligned in cardboard
2; 16
8595057657229
ST
individual boxes fitted with screws for mounting into double wall and covered with label, device screws are fitted in boxes
16
8595568903631
KP 64/5L
J U N C T I O N B O X E S i n t o
For modern installations in combined frames. Significant rigidity makes device installation easier. Tips for marking hole centres for installation holes in the double wall. Mounting screws are fitted with a triple thread for quick installation. Sold in the smallest complete packages (2 pcs). When mounting, it is not necessary to countersink the plasterboard edge.
- accessories
VPTU; VPT 64; P1 ∅ 68 mm pg. 1-71
TYP0... pg. 1-70
KO 97/L
- junction box with cover KO 97 V/1
PVC
d o u b l e
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KO 97/L
NA
boxes fitted with screws for installation in double wall and with included lids separately placed into cardboard
80
Sufficient space for making more extensive wiring installations. Mounting screws are fitted with a triple thread for quick installation.
w a l l s
- accessories
S-96 pg. 1-68
24
- auxiliary tools
- auxiliary tools
SP-96 pg. 1-68
VPTU; VPT 97; P1 ∅ 103,5 mm pg. 1-71
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
leadless material
fire class
flaming loop test
spacing when joining boxes
package
8595057600171
KR 97/L
1
- junction box with cover KO 97 V/1 and terminal plate SP-96
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KR 97/L
NA
boxes fitted with terminal plate and screws for installation in double wall, with included lids separately placed into cardboard
8595057600263
Sufficient space for making more extensive wiring installations. Mounting screws are fitted with a triple thread for quick installation.
- accessories
J U N C T I O N
- auxiliary tools
B O X E S i n t o
VPTU; VPT 97; P1 ∅ 103,5 mm pg. 1-71
TYP0... pg. 1-70
SP-96 pg. 1-68
S-96 pg. 1-68
KO 110/L
80
- junction box with cover V 110 L and partition wall P 110 L
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
NA
lid screws inserted together with partition into box, each box with a lid sealed in shrink foil and labelled
1; 28
8595057611672
ST
screws for mounting the box into double wall installed in the box, lid screwed to the box and box labelled
36
8595057699434
KO 110/L
Box can be used with terminal S-96 or two terminals S-66, which are separated by a partition. Possibility to connect two different circuits of up to 400 V separated by a partition. Mounting screws are fitted with a triple thread for quick installation.
- accessories
S-66 pg. 1-68
- auxiliary tools
S-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
leadless material
SP-96 pg. 1-68
TYP0... pg. 1-70
d o u b l e w a l l s
VPTU; VPT 40; P1 ∅ 40 mm pg. 1-71
package
25
1
KO 125/1L
- junction box with cover V 125/1
PVC
-5 - +60°C
850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
KO 125/1L
J U N C T I O N B O X E S i n t o
NA
lid screws and mounting screws placed in box, each box with lid sealed in shrink film
ST
lid mounted on the box, each box labelled with bar code
1; 27
8595057668652
18
8595057699441
A large number of knockouts for introducing cables and pipes. Possibility to install the support trunking TS 35.
- auxiliary tools
Possibility to set the lid in a horizontal position. Possibility to break the sidewall for easier cable handling. Outer side of the bottom contains holes for marking drill holes. Mounting screws are fitted with a triple thread for quick installation.
VPTU; VPT 40; P1 ∅ 40 mm pg. 1-71
- accessories
S-96 pg. 1-68
S-66 pg. 1-68
KT 250/L
TYP0... pg. 1-70
TS35 pg. 2-46
- junction box with cover VKT 250/L
PVC
d o u b l e
EPS 2 pg. 1-70
SP-96 pg. 1-68
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
NB
screws placed in each box, covered with a lid, wrapped in shrink foil and labelled with a bar code
1; 12
8595057618640
ST
individual boxes fitted with bolts, bolted cover, boxes labelled with a bar code
12
8595057699458
KT 250/L
w a l l s
A large number of knockouts for introducing cables and pipes.
- auxiliary tools
Possibility to install the support trunking TS 35. Possibility to set the lid in a horizontal position. Possibility to break the sidewall for easier cable handling. Outer side of the bottom contains holes for marking drill holes. Mounting screws are fitted with a triple thread for quick installation. VPTU; VPT 40; P1 ∅ 40 mm pg. 1-71
- accessories
S-66 pg. 1-68
26
S-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
leadless material
SP-96 pg. 1-68
EPS 2 pg. 1-70
package
TYP0... pg. 1-70
TS35 pg. 2-46
KPM 64/LU
1
- junction box with assembly ring MKU 64
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KPM 64/LU
NA
box with rings separately packed in a cardboard
8595057612648
For mounting into plaster with a thickness of 12.5 mm. Assembly ring enables installation even in double double wall of 2x 12.5 mm. Quick installation without screws - only pressed into the assembly ring. During the assembling there is necessary to dimple the edge of plasterboard.
- accessories
J U N C T I O N
- auxiliary tools
V 68 pg. 1-60
KO 68 pg. 1-59
KOM 97/LU
90
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
- junction box with assembly ring MKU 97 and cover KO 97/V1
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KOM 97/LU
NA
individual boxes aligned in cardboard, lids and assembly rings included
40
Large number of inlets. For mounting into plaster with a thickness of 12.5 mm. Assembly ring enables installation even in double double wall of 2x 12.5 mm. Quick installation without screws - only pressed into the assembly ring.
- accessories
S-96 pg. 1-68
- auxiliary tools
SP-96 pg. 1-68
8595057612617
B O X E S i n t o d o u b l e w a l l s
VPTU; VPT 97; P1 ∅ 103,5 mm pg. 1-71
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
leadless material
fire class
flaming loop test
for mounting and double-socket
package
27
1
KUH 1/L
- junction box
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KUH 1/L
J U N C T I O N B O X E S i n t o d o u b l e
NA
inserted into each box are installation and device screws, each box is i ndividually wrapped in shrink film and labelled
1; 35
8595057687950
Installation on the reverse side of double wall with a thickness of 12.5 mm using the included screws. More space in the box allows the insertion of active elements under the device. Possibility to insert the terminal S-66 directly under the device. Suitable for modern electrical system with higher space requirements.
- accessories
V 68 pg. 1-60
- auxiliary tools
S-66 pg. 1-68
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
Assembling procedures and examples of using the KUH 1/L box 1) Drilling the hole with Ø73.5 mm in the plaster wall by means of the VDS 68 drill (see page 1-72).
2) Inserting the KUH 1/L box into the prepared hole. Covering the box with the bottom plate.
3) Side view (in sectional view) of box inserted from the back side of the plaster board.
4) Self-drilling screw fastening of the box. Detail of separate space for screw.
5) Examples of using the box (in sectional view): e.g. inserting of over-voltage protection, clamping by means of screwless terminals, using of the S-66 terminal plate.
w a l l s KOPOBOX mini L Configuration of multi-purpose mounting box for modular equipment to be suitable for mounting into the hollow walls. More in pg. 1-74
28
material
temperature resistance
self-snuffing
leadless material
fire class
flaming loop test
for mounting and double-socket
package
1
Examples of assembling the boxes into a cavity wall Installation of a rectangular box
1. Determining the mounting position, pushing the drill centers
2. Corner holes drilling.
Fixing box with assembling ring
1. Drilling an opening into a hollow wall using a drill VDS 68.
2. Embedding an assembling ring to a gypsum wall.
3. Cut line tracing.
3. Embedding a box into an assembling ring.
4. Cutting out and removal of cut residue.
4. Easy and fast installation – time saving up to 25%.
Installation of multiple box in the plaster wall
1. Drilling holes.
2. Installation of devices with axis distance of 71 mm (horizontal frame).
3. Final box covering (KP 64/4L) with installed devices.
B O X E S i n t o d o u b l e
5. Inserting the box and power-installing. Box fixation with abutment screw.
J U N C T I O N
Mounting the S-66 terminal plate into KPR 68/L
w a l l s
29
1
LK 80/1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80/1
boxes packed in shrink film in packages of 10 pieces, device screws included
8595057616387
To install on materials with fire classes E or F, use insulating pad.
- accessories
LK 80/2
S-66 pg. 1-68
PI 80R pg. 1-67
VLK 80 pg. 1-62
TYP0... pg. 1-70
- junction box with cover VLK 80
PVC
-5 - +60°C
item
t r u n k i n g s
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80/2
HB
boxes packed in shrink film in packages of 10 pieces, lid screws included, 10; 120 lids individually wrapped in packages of 10 pieces
Its shape is also suitable for older devices. Inserting terminal plate S-66. To install on materials with fire classes E or F, use insulating pad. The lid can be purchased separately.
- accessories
PI 80R pg. 1-67
30
10; 160
Its shape is also suitable for older devices.
J U N C T I O N B O X E S f o r
HB
S-66 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
TYP0... pg. 1-70
8595057616394
LK 80/3
1
- junction box with cover VLK 80 and terminal plate S-66
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80/3
boxes packed in shrink film in a package of 10 pieces and, included are terminal plate screws, lid screws, lids packed separately in packages of 10 10; 100 pieces, as are the terminal plates, all labelled
HB
8595057616400
Its shape is also suitable for older devices. Inserting terminal plate S-66. To install on materials with fire classes E or F, use insulating pad. Lids and terminal plates can be purchased separately.
J U N C T I O N
- accessories
TYP0... pg. 1-70
PI 80R pg. 1-67
LK 80X28/1
B O X E S f o r
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X28/1
HB
boxes packed in shrink film in packages of 10 pieces, device screws 10; 100 included
To repair older installations. To install on materials with fire classes E or F, use insulating pad. Intended for installation of sockets and other devices. Allows installation of devices with greater mounting depth.
8595057617193
t r u n k i n g s
- accessories
VLK 80 pg. 1-62
PI 80R pg. 1-67
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
S-66 pg. 1-68
TYP0... pg. 1-70
31
1
LK 80R/1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80R/1
boxes packed in shrink film in packages of 10 pieces, device screws included 10; 160
To install on materials with fire classes E or F, use insulating pad.
- accessories
LK 80R/2
PI 80R pg. 1-67
NR 80/R pg. 1-64
VLK 80/R pg. 1-63
S-66 pg. 1-68
TYP0... pg. 1-70
- junction box with cover VLK 80/R
PVC
-5 - +60°C
item
t r u n k i n g s
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80R/2
HB
boxes packed in shrink film in packages of 10 pieces, device screws included 10; 120
To install on materials with fire classes E or F, use insulating pad. The lid can be purchased separately.
- accessories
NR 80/R pg. 1-64
32
8595057616349
Intended for devices of Classic and Swing - ABB series.
J U N C T I O N B O X E S f o r
HB
PI 80R pg. 1-67
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
S-66 pg. 1-68
TYP0... pg. 1-70
8595057616356
LK 80R/3
1
- junction box with cover VLK 80/R and terminal plate S-66
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80R/3
boxes packed in shrink film in and package of 10 pieces and, included are terminal plate screws, lid screws, lids packed separately in packages of 10 10; 100 pieces, as are the terminal plates, all labelled
HB
8595057616363
To install on materials with fire classes E or F, use insulating pad. Cover and terminal plates can be purchased separately.
J U N C T I O N
- accessories
LK 80X20R/1
TYP0... pg. 1-70
PI 80R pg. 1-67
NR 80/R pg. 1-64
B O X E S f o r
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X20R/1
HB
boxes packed in shrink film in packages of 10 pieces, device screws included
Intended for devices of Classic and Swing - ABB series with greater mounting depth. To install on materials with fire classes E or F, use insulating pad.
10; 160
8595057616486
t r u n k i n g s
- accessories
VLK 80/R pg. 1-63
NR 80/R pg. 1-64
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
PI 80R pg. 1-67
S-66 pg. 1-68
TYP0... pg. 1-70
33
1
LK 80X28R/1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
HB
boxes packed in shrink film in packages of 10 pieces, device screws 10; 120 included, color - white RAL 9003
8595057616479
I1
boxes packed in shrink film in packages of 10 pieces, device screws 10; 120 included, color - pink birch
8595568908940
I2
boxes packed in shrink film in packages of 10 pieces, device screws 10; 120 included, color - dark oak
8595568908988
SD
boxes packed in shrink film in packages of 10 pieces, device screws 10; 120 included, color - light brown
8595568909022
LK 80X28R/1
To be intended for equipment of model range Classic or Swing - ABB with high assembling depth – with the exception of small double socket.
J U N C T I O N B O X E S f o r
To install on materials with fire classes E or F, use insulating pad.
- accessories
LK 80X28 2ZK
S-66 pg. 1-68
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
HB
boxes packed in shrink film in packages of 10 pieces, device screws included, color - white RAL 9003
10; 80
8595057616370
I1
boxes packed in shrink film in packages of 10 pieces, device screws included, color - pink birch
10; 80
8595568908957
I2
boxes packed in shrink film in packages of 10 pieces, device screws included, color - dark oak
10; 80
8595568908995
SD
boxes packed in shrink film in packages of 10 pieces, device screws included, color - light brown
10; 80
8595568909039
LK 80X28 2ZK
Intended for devices of Classic - ABB series. To install on materials with fire classes E or F, use insulating pad.
- accessories
PI 80 2ZK pg. 1-67
34
TYP0... pg. 1-70
- junction box
PVC
t r u n k i n g s
PI 80R pg. 1-67
NR 80/R pg. 1-64
VLK 80/R pg. 1-63
material
temperature resistance
self-snuffing
fire class
flaming loop test
for mounting and double-socket
package
LK 80X28 2R
1
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X28 2R
boxes packed in shrink film in packages of 10 pieces, device screws included for 2 devices included
HB
10; 60
8595057615519
Intended for devices of Classic and Swing - ABB series with greater mounting depth. To install on materials with fire classes E or F, use insulating pad (2 pcs PI 80 2ZK). Installation of two devices or and double-socket.
J U N C T I O N
- accessories
VLK 80/2R pg. 1-63
VLK 80/R pg. 1-63
LK 80X16 T
PI 80 2ZK pg. 1-67
S-66 pg. 1-68
TYP0... pg. 1-70
B O X E S f o r
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X16 T
HB
boxes packed in shrink film in packages of 10 pieces, device screws included
Intended for devices of Tango - ABB series. To install on materials with fire classes E or F, use insulating pad.
10; 160
8595057619296
t r u n k i n g s
- accessories
VLK 80/T pg. 1-63
PI 80 T pg. 1-67
S-66 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
for mounting and double-socket
TYP0... pg. 1-70
package
35
1
LK 80X28 T
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
HB
boxes packed in shrink film in packages of 10 pieces, device screws 10; 100 included, color - white RAL 9003
8595057617308
I1
boxes packed in shrink film in packages of 10 pieces, device screws 10; 100 included, color - pink birch
8595568908964
I2
boxes packed in shrink film in packages of 10 pieces, device screws 10; 100 included, color - dark oak
8595568909008
SD
boxes packed in shrink film in packages of 10 pieces, device screws 10; 100 included, color - light brown
8595568909046
LK 80X28 T
J U N C T I O N B O X E S f o r
Intended for devices of Tango with greater mounting depth. To install on materials with fire classes E or F, use insulating pad.
- accessories
LK 80X28 2ZT
S-66 pg. 1-68
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
HB
boxes packed in shrink film in packages of 10 pieces, device screws included, color - white RAL 9003
10; 80
8595057616332
I1
boxes packed in shrink film in packages of 10 pieces, device screws included, color - pink birch
10; 80
8595568908971
I2
boxes packed in shrink film in packages of 10 pieces, device screws included, color - dark oak
10; 80
8595568909015
SD
boxes packed in shrink film in packages of 10 pieces, device screws included, color - light brown
10; 80
8595568909053
LK 80X28 2ZT
Intended for devices of Tango. To install on materials with fire classes E or F, use insulating pad.
- accessories
NR 2ZT pg. 1-64
36
TYP0... pg. 1-70
- junction box
PVC
t r u n k i n g s
PI 80T pg. 1-67
NRT pg. 1-63
VLK 80/T pg. 1-63
PI 80 2ZT pg. 1-67
S-66 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
for mounting and double-socket
TYP0... pg. 1-70
package
LK 80X28 2T
1
- junction box
PVC
-5 - +60°C
850°C
item
A1 - D
30 sec.
71
conf.
description
EAN pcs
LK 80X28 2T
HB
boxes packed in shrink film in packages of 10 pieces, device screws included for 2 devices included
10; 60
8595057617315
Intended for two devices of Tango - ABB series in and combined frame For installation of two units horizontally.
To install on materials with fire classes E or F, use insulating pad – to support, use 2 pads PI 80 2ZT and adjust to the desired size.
J U N C T I O N
- accessories
TYP0... pg. 1-70
PI 80 2ZT pg. 1-67
LKM 45
B O X E S f o r
- junction box
PVC
-5 - +60°C
item
850°C
A1 - D
30 sec.
conf.
description
EAN pcs
LKM 45
HB
boxes packed in shrink film in packages of 10 pieces, device screws included
Universal box for most single devices available on the market. Trunking inlet holes are indicated on the side, for trunking with dimensions of up to 40 x 20 mm. The box consists of two parts, the top and bottom part. To install on materials with fire classes E or F, use insulating pad.
material
temperature resistance
self-snuffing
fire class
flaming loop test
rozteč při spojení krabic
10; 120
8595057634855
t r u n k i n g s
package
37
KSK 80
1
- junction box with IP protection
PP
-25 - +60°C
850°C
A1 - F
30 sec.
IP66
cover - PC
item
conf.
description
EAN pcs
KSK 80
KA
plugs and lid screws inserted in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 60
8595568910608
Intended for installation in environments that require IP 66 protection. Integrated knockouts for mounting on base. Intended for direct installation on the surface without having to support with insulating pad. Perfect sealing of cables and pipes. Stainless steel screws for lid installation, halogen-free material, the option to install special terminal block. Integrated O-ring to install cable glands. 8x knockouts with ∅20 mm.
J U N C T I O N
- accessories
S-KSK 1 pg. 1-41
S-66 pg. 1-68
KSK 100
TYP0... pg. 1-70
- junction box with IP protection
PP
-25 - +60°C
850°C
A1 - F
30 sec.
IP66
cover - PC
item
conf.
description
EAN pcs
KSK 100
KA
plugs and lid screws inserted in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 30
8595568910615
Intended for installation in environments that require IP 66 protection. Integrated knockouts for mounting on base. Intended for direct installation on the surface without having to support with insulating pad.
B O X E S c l o s e d
Perfect sealing of cables and pipes. Stainless steel screws for lid installation, halogen-free material, the option to install special terminal block. Integrated O-ring to install cable glands. Alternatively the box is also available as fire resistant box, see the catalogue Systems maintaining functionality during fire. 7x knockouts with ∅25 mm and 1x ∅20 mm. - accessories
S-66 pg. 1-68
S-KSK 1 pg. 1-41
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
halogen-free material
fire class
flaming loop test
leadless material
IP classification
package
39
1
KSK 125
- junction box with IP protection
PP
-25 - +60°C
850°C
A1 - F
30 sec.
IP66
cover - PC
item
conf.
description
EAN pcs
KSK 125
plugs and lid screws inserted in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 36
Integrated knockouts for mounting on base. Intended for direct installation on the surface without having to support with insulating pad. Perfect sealing of cables and pipes. Stainless steel screws for lid installation, halogen-free material, the option to install special terminal block. Integrated O-ring to install cable glands. 4x knockouts with ∅20 mm, 6x ∅25 mm and 5x ∅32 mm.
- accessories
KSK 175
SP-96 pg. 1-68
S-96 pg. 1-68
S-66 pg. 1-68
S-KSK 2 pg. 1-41
TYP0... pg. 1-70
TS35 pg. 2-46
- junction box with IP protection
PP
-25 - +60°C
850°C
A1 - F
30 sec.
IP66
cover - PC
item
conf.
description
EAN pcs
KSK 175
KA
plugs and lid screws inserted in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 22
Intended for installation in environments that require IP 66 protection. Integrated knockouts for mounting on base. Intended for direct installation on the surface without having to support with insulating pad. Perfect sealing of cables and pipes. Stainless steel screws for lid installation, halogen-free material, the option to install special terminal block. Integrated O-ring to install cable glands. 7x knockouts with ∅20 mm, 12x ∅25 mm, 7x ∅32 mm and 3x ∅40 mm.
- accessories
S-66 pg. 1-68
40
8595568919670
Intended for installation in environments that require IP 66 protection.
J U N C T I O N B O X E S c l o s e d
KA
S-96 pg. 1-68
SP-96 pg. 1-68
S-KSK 2 pg. 1-41
material
temperature resistance
self-snuffing
halogen-free material
fire class
flaming loop test
leadless material
IP classification
TYP0... pg. 1-70
TS35 pg. 2-46
package
8595568919687
S-KSK 1
1
- terminal plate
PP
-40 - +85°C
item
S-KSK 1
850°C
A1 - F
30 sec.
conf.
KB
description
EAN
branch terminal plate of five separate terminals
pcs
mm2
4 or 3
1,5 - 2,5
pcs
10
8595568919656
4
Suitable for boxes KSK 80 and KSK 100. Enables easy assembly to the box bottom. Designed for and maximum voltage of 500 V. Tested according to ČSN EN 60998-1.
J U N C T I O N
S-KSK 2
- terminal plate
PP
-40 - +85°C
item
S-KSK 2
850°C
A1 - F
30 sec.
conf.
KB
description
EAN
branch terminal plate of five separate terminals
pcs
mm2
4 or 3
2,5 - 4
pcs
10
8595568919663
6
Suitable for boxes KSK 125 and KSK 175.
Allows mounting to posts inside boxes or to the box bottom – installation is done using screws that are included.
B O X E S c l o s e d
Designed for and maximum voltage of 500 V. Tested according to ČSN EN 60998-1.
material
temperature resistance
self-snuffing
number of conductors x diameter (mm2), load-current capacity: (A)
fire class
flaming loop test
halogen-free material
package
41
1
8101
- junction box with sealing 1601
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 55
8595057608801
KA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 55
8595057655959
8101
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
Universal grommets for cables and pipes, grommets can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad.
J U N C T I O N B O X E S c l o s e d
- accessories
8102
- junction box with sealing 1601 and terminal plate S-66
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 55
8595057608818
KA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 55
8595057655966
8102
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
42
TYP0... pg. 1-70
S-66 pg. 1-68
Universal grommets for cables and pipes, grommets and terminal plates can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad.
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
package
8106
1
- junction box with sealing G-49
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP40
conf.
description
EAN pcs
LA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 100
8595057603332
KA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 100
8595057655973
8106
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
Universal grommets for cables and pipes, grommets can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad.
J U N C T I O N
- accessories
TYP0... pg. 1-70
S-66 pg. 1-68
8107
- junction box with sealing G-49 and terminal plate S-66
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP40
conf.
description
EAN pcs
LA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 100
8595057603387
KA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 100
8595057655980
8107
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased
B O X E S c l o s e d
risk of mechanical damage.
Universal grommets for cables and pipes, grommets and terminal plates can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad.
- accessories
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
package
43
1
8110
- junction box with sealing 1611
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 28
8595057603349
KA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 28
8595057655997
8110
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
Universal grommets for cables and pipes, grommets can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad. Alternatively the box is also available as fire resistant box, see the catalogue Systems maintaining functionality during fire.
J U N C T I O N B O X E S c l o s e d
- accessories
8111
TYP0... pg. 1-70
SP-96 pg. 1-68
S-96 pg. 1-68
- junction box with sealing 1611 and terminal plate S-96
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 20
8595057603394
KA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 20
8595057656000
8111
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
Universal grommets for cables and pipes, grommets and terminal plates can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad.
- accessories
SP-96 pg. 1-68
44
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
package
8112
1
- junction box
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
lid screws placed in the box, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 28
8595057603356
KA
lid screws placed in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 28
8595057656017
8112
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
To install on materials with fire classes E or F, use thermally insulating pad.
J U N C T I O N
- accessories
8117
TYP0... pg. 1-70
SP-96 pg. 1-68
S-96 pg. 1-68
- junction box with sealing 1618
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 24
8595057603363
KA
cable grommets and lid screws placed in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 24
8595057656024
8117
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
B O X E S c l o s e d
Universal grommets for cables and pipes, grommets can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad. Alternatively the box is also available as fire resistant box, see the catalogue Systems maintaining functionality during fire.
- accessories
S-96 pg. 1-68
SP-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
TYP0... pg. 1-70
package
45
1
8118
- junction box with sealing 1618 and terminal plate S-96
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
LA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 24
8595057603400
KA
cable grommets terminal plates and lid screws placed in the box, each box packed in shrink foil and labelled, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 24
8595057656031
8118
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
Universal grommets for cables and pipes, grommets and terminal plates can be ordered separately. To install on materials with fire classes E or F, use thermally insulating pad. Terminal plate can be bought separately.
J U N C T I O N B O X E S c l o s e d
- accessories
TYP0... pg. 1-70
SP-96 pg. 1-68
8119
- junction box
PVC
-5 - +60°C
item
650°C
A1 - D
30 sec.
IP54
conf.
description
LA
lid screws placed in the box, each box packed in shrink foil and labelled, color - dark grey RAL 7012
1; 24
8595057603370
KA
lid screws placed in the box, each box packed in shrink foil and labelled, color - light grey RAL 7035
1; 24
8595057656048
8119
For installation in environment with increased humidity, dust, chemical and corrosion resistance, in environments with increased risk of mechanical damage.
To install on materials with fire classes E or F, use thermally insulating pad.
- accessories
S-96 pg. 1-68
46
EAN pcs
SP-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
TYP0... pg. 1-70
package
8130
1
- junction box
PP
PE
cover
body
item
-5 - +60°C
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
8130
HA
boxes packed loosely in cardboard, color - white RAL 9003
60
8595057697300
KA
boxes packed loosely in cardboard, color - light grey RAL 7035
60
8595057619050
For installation in environments with increased humidity and dust. Inlets for cables or pipes of 16 and 20 mm in accordance with EN 60423. Possibility to install on materials of fire classes A1 to D.
J U N C T I O N
- accessories
TYP0... pg. 1-70
TYP... pg. 1-69
8135
- junction box
PP
PE
cover
body
item
-5 - +60°C
650°C
A1 - D
30 sec.
IP54
conf.
description
EAN pcs
8135
HA
boxes packed loosely in cardboard, color - white RAL 9003
30
8595057697317
KA
boxes packed loosely in cardboard, color - light grey RAL 7035
30
8595057616493
For installation in environments with increased humidity and dust. Inlets for cables or pipes of 16, 20 and 25 mm in accordance with EN 60423. Possibility to install on materials of fire classes A1 to D.
B O X E S c l o s e d
Alternatively the box is also available as fire resistant box, see the catalogue Systems maintaining functionality during fire.
- accessories
S-96 pg. 1-68
SP-96 pg. 1-68
material
temperature resistance
self-snuffing
fire class
flaming loop test
IP classification
TYP... pg. 1-69
TYP0... pg. 1-70
package
47
1
003.CS.K
- junction box with protection
PP
PE
cover
body
item
-5 - +60°C
750°C
A1
IP65
conf.
description
EAN pcs
003.CS.K
boxes packed loosely in cardboard, color - light grey RAL 7035
8595057624658
To install on materials with fire classes A2-D, use thermally insulating pad. Not to be installed on materials with fire classes E and F.
- accessories
TYP0... pg. 1-70
005.CS.K
- junction box with protection
PP
PE
cover
body
item
-5 - +60°C
750°C
A1
IP65
conf.
description
EAN pcs
005.CS.K
KB
boxes packed loosely in cardboard, color - light grey RAL 7035
Equipped with an eye for sealing. To install on materials with fire classes A2-D, use thermally insulating pad. Not to be installed on materials with fire classes E and F.
- accessories
TYP0... pg. 1-70
48
1; 90
Equipped with an eye for sealing.
J U N C T I O N B O X E S c l o s e d
KB
material
temperature resistance
self-snuffing
IP classification
fire class
flaming loop test
halogen-free material
package
1; 56
8595057624665
7116 B 7116 C
1
- metal box with cover and protective terminal - metal box with cover
AL
-25 - +70°C
item
A1 - D
IP54
conf.
description
EAN pcs
7116 B 7116 C
P16
glands for threaded pipes P16
1; 12
8595057604124
M20
glands for threaded pipes M20
1; 12
8595057689527
P16
glands for threaded pipes P16
1; 12
8595057604131
M20
glands for threaded pipes M20
1; 12
8595057689534
Boxes for piping with steel threaded or metal flexible pipes. Three glands and one plug evenly distributed on the sides of the box. Terminal plate is not included in the box. 7116 B: fitted with a clamp for installation in TNS networks. 7116 C: without protective terminal for installation in TNC networks.
J U N C T I O N
- accessories
TYP0... pg. 1-70
6303-11 pg. 1-69
7216 B 7216 C
- metal box with cover and protective terminal - metal box with cover
AL
-25 - +70°C
item
A1 - D
IP54
conf.
description
EAN pcs
7216 B 7216 C
P16
glands for threaded pipes P16
1; 12
8595057604186
M20
glands for threaded pipes M20
1; 12
8595057689541
P16
glands for threaded pipes P16
1; 12
8595057604193
M20
glands for threaded pipes M20
1; 12
8595057689558
Boxes for piping with steel threaded or metal flexible pipes.
B O X E S c l o s e d
Four glands and one plug evenly distributed on the sides of the box. Terminal plate is not included in the box. 7216 B: fitted with a clamp for installation in TNS networks. 7216 C: without protective terminal for installation in TNC networks.
- accessories
6303-11 pg. 1-69
material
temperature resistance
fire class
IP classification
TYP0... pg. 1-70
package
49
1
7121 B 7121 C
- metal box with cover and protective terminal - metal box with cover
AL
-25 - +70°C
item
A1 - D
IP54
conf.
description
EAN pcs
7121 B 7121 C
glands for threaded pipes P21
1; 12
8595057604155
glands for threaded pipes M25
1; 12
8595057689565
P21
glands for threaded pipes P21
1; 12
8595057604162
M25
glands for threaded pipes M25
1; 12
8595057689572
Boxes for piping with steel threaded or metal flexible pipes. Three glands and one plug evenly distributed on the sides of the box. Terminal plate is not included in the box. 7121 B: fitted with a clamp for installation in TNS networks. 7121 C: without protective terminal for installation in TNC networks.
J U N C T I O N B O X E S c l o s e d
P21 M25
- accessories
TYP0... pg. 1-70
6303-12 pg. 1-69
7221 B 7221 C
- metal box with cover and protective terminal - metal box with cover
AL
-25 - +70°C
item
A1 - D
IP54
conf.
description
7221 B 7221 C
P21
glands for threaded pipes P21
1; 12
8595057604216
M25
glands for threaded pipes M25
1; 12
8595057689589
P21
glands for threaded pipes P21
1; 12
8595057604223
M25
glands for threaded pipes M25
1; 12
8595057689596
Boxes for piping with steel threaded or metal flexible pipes. Four glands and three plugs evenly distributed on the sides of the box. Terminal plate is not included in the box. 7221 B: fitted with a clamp for installation in TNS networks. 7221 C: without protective terminal for installation in TNC networks.
- accessories
6303-12 pg. 1-69
50
EAN pcs
material
temperature resistance
fire class
IP classification
TYP0... pg. 1-70
package
1601
1
- sealings
PVC
-5 - +60°C
item
30 sec.
conf.
description
EAN pcs
1601
G-49
LB
color - dark grey
200; 1200
8595057627222
KB
color - light grey
200; 1200
8595057656703
For 8101 and 8102 type boxes. Suitable for pipe with and diameter of 20 mm. When removing the projections, it is designed for cables of max. 16 mm in diameter.
- sealings
PVC
-5 - +60°C
item
30 sec.
conf.
description
EAN pcs
G-49
1611; 1618
HA
color - white
500
8595057623996
KA
color - light grey
500
8595057652392
LA
color - dark grey
500
8595057624009
B O X E S c l o s e d
To seal inlets to boxes 8106 and 8107. To install cables, cut off projections and thread the cable.
- sealings
PVC
-5 - +60°C
item
30 sec.
conf.
J U N C T I O N
description
EAN pcs
1611 1618
KB
color - light grey
7; 672
8595057656710
LB
color - grey
7; 672
8595057629325
KB
color - light grey
7; 504
8595057656727
LB
color - grey
7; 504
8595057629332
Holes for cable and pipe inlet are marked gradually. Grommet 1611: for 8110 and 8111 type boxes, for pipes with 16, 25, 32 in dimension. Grommet 1618: for 8117 and 8118 type boxes, for pipes with 16, 25, 32 and 40 in dimension.
material
self-snuffing
temperature resistance
package
51
1
P-16; P-21
- sealing cork
AL
-25 - +70°C
item
description
EAN pcs
P-16
plug with armoured P16 thread and seal
10; 500
8595057632660
P-21
plug with armoured P21 thread and seal
10; 400
8595057632677
J U N C T I O N B O X E S c l o s e d
material
52
temperature resistance
package
P-16: to seal unused inlets of metal boxes 7116 and 7216. P-21: to seal unused inlets of metal boxes 7121 and 7221.
KU 68-1901HF
1
- universal box
PPO
-45 - +105°C 850°C
item
A1 - D
30 sec.
71
conf.
description
EAN pcs
KU 68-1901HF
FA
packed in shrink film, packaging labelled, screws included
8595057633957
Possibility to join into a continuous series with a spacing of 71 mm. Connection of up to three boxes in a row is recommended. For premises with increased need for protection of persons and property.
- accessories
J U N C T I O N
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
S-66 pg. 1-68
V 68HF pg. 1-56
KP 68/2HF
10; 100
- instrument box
PPO
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
KP 68/2HF
FA
packed in shrink film, packaging labelled, screws included
10; 150
For premises with increased need for protection of persons and property.
- accessories
V 68HF pg. 1-56
8595057634923
B O X E S h a l o g e n f r e e
- auxiliary tools
FR 68 SDS ∅ 80 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
for mounting and double-socket
leadless material
fire class
flaming loop test
spacing when joining boxes
halogen-free material
package
53
1
KOM 97HF
- box with cover KO 97 V/1 HF
PPO
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
KOM 97HF
boxes and lids packed loosely in cardboard
8595057635012
Lid KO 97 V/1HF can be ordered separately.
- accessories
KU 68 LA/1HF
TYP0... pg. 1-70
SP-96 pg. 1-68
S-96 pg. 1-68
- universal box in hollow walls
PPO
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
KU 68 LA/1HF
FA
boxes fitted with screws and bases for easy mounting to drywall, device screws included, packed loosely in cardboard
90
8595057633964
For premises with increased need for protection of persons and property. While stocks last.
- accessories
S-66 pg. 1-68
54
40
For premises with increased need for protection of persons and property.
J U N C T I O N B O X E S h a l o g e n f r e e
FA
- auxiliary tools
VDS 68 + ZBU ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
halogen-free material
fire class
flaming loop test
for mounting and double-socket
leadless material
package
VPTU; VPT 68; P1, ZBU ∅ 73,5 mm pg. 1-71
KU 68 LD/1HF
1
- universal box in hollow walls
PP
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KU 68 LD/1HF
boxes fitted with screws for mounting into drywall, device screws are fitted in boxes
HA
8595568910585
For premises with increased need for protection of persons and property. Inlets provide airtightness, suitable for installations with emphasis on minimizing heat los.
- accessories
J U N C T I O N
- auxiliary tools
VPTU; VPT 68; P1 ∅ 73,5 mm pg. 1-71
VDS 68 ∅ 73,5 mm pg. 1-72
TYP0... pg. 1-70
S-66 pg. 1-68
V 68HF pg. 1-56
KP 64/LD HF
90
- instrument box in hollow walls
PP
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KP 64/LD HF
HA
boxes fitted with screws for mounting into drywall, device screws are fitted in boxes
100
For premises with increased need for protection of persons and property. Inlets provide airtightness, suitable for installations with emphasis on minimizing heat los.
- accessories
V 68HF pg. 1-56
8595568910578
B O X E S h a l o g e n f r e e
- auxiliary tools
VPTU; VPT 64; P1 ∅ 68 mm pg. 1-71
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
halogen-free material
fire class
flaming loop test
for mounting and double-socket
leadless material
package
55
1
V 68HF
- cover
PC
-45 - +105°C 850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
V 68HF
HB
lids in packs of 10 pcs, sealed in shrink film, color white RAL 9003
For premises with increased need for protection of persons and property. To cover the boxes with fixing spacing of 60 mm using fastening screws.
J U N C T I O N B O X E S h a l o g e n f r e e
56
material
temperature resistance
self-snuffing
fire class
flaming loop test
halogen-free material
package
10; 100
8595057634114
LK 80X28R/1HF
1
- instrument box
PC
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X28R/1HF
HB
boxes packed in shrink film in packages of 10 pieces, device screws 10; 100 included
8595057634121
For premises with increased need for protection of persons and property. To be intended for equipment of model range Classic or Swing - ABB with high assembling depth – with the exception of small double socket.
To install on materials with fire classes E or F, use insulating pad.
J U N C T I O N
- accessories
PI 80R pg. 1-67
LK 80X28 2ZKHF
S-66 pg. 1-68
TYP0... pg. 1-70
- instrument box
PC
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X28 2ZKHF
boxes packed in shrink film in packages of 10 pieces, device screws included
HB
For premises with increased need for protection of persons and property. Intended for double-socket of Classic series. To install on materials with fire classes E or F, use insulating pad.
10; 100
8595057634138
B O X E S h a l o g e n f r e e
- accessories
PI80 2ZK pg. 1-67
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
halogen-free material
fire class
flaming loop test
for mounting and double-socket
package
57
1
LK 80X28 THF
- instrument box
PC
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X28 THF
boxes packed in shrink film in packages of 10 pieces, device screws included
8595057633995
Intended for devices of Tango series. To install on materials with fire classes E or F, use insulating pad.
- accessories
PI 80T pg. 1-67
LK 80X28 2THF
TYP0... pg. 1-70
- instrument box
PC
-45 - +105°C 850°C
item
A1 - D
30 sec.
conf.
description
EAN pcs
LK 80X28 2THF
boxes packed in shrink film in packages of 10 pieces, device screws included
HB
For premises with increased need for protection of persons and property. Intended for double-sockets of Tango series. To install on materials with fire classes E or F, use insulating pad.
- accessories
PI 802ZT pg. 1-67
58
10; 100
For premises with increased need for protection of persons and property.
J U N C T I O N B O X E S h a l o g e n f r e e
HB
TYP0... pg. 1-70
material
temperature resistance
self-snuffing
halogen-free material
fire class
flaming loop test
for mounting and double-socket
package
10; 80
8595057634145
KO 68
1
- cover
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KO 68
KO 97 V
HB
lids packed loosely in cardboard
100
8595057600539
For the final covering of boxes KU 68-1901, KU 68-1902, KU 68-1903 and KPM 64/LU.
J U N C T I O N
- cover
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KO 97 V
KO 97 V/1
HB
lids packed loosely in cardboard
40
8595057600546
For the final covering of distribution and branch boxes KO 97/5, KR 97/5 and KOM 97.
- cover
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KO 97 V/1
HB
lids packed loosely in cardboard
40
B O X E S a c c e s s o r i e s
8595057612983
For the final covering of distribution and branch boxes KO 97/5, KO 97/L, KR 97/5, KR 97/L, KOM 97 and KOM 97/L. The lid is provided with edge that allows trouble-free covering of wiring boxes installed in concrete or hollow walls.
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
59
1
TN...
- extending piece
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
TN 68 TN 97
KB
for boxes KU 68-1901, 1902, 1903 a KPM 64/LU, color - grey
10; 800
8595057698512
HB
for boxes KO 97/5, KR 97/5, KOM 97, KO 97/L, KR 97/L, KOM 97/LU, color - white
10; 800
8595057698529
To extend the central pin of cover lids, for boxes that are too recessed, where the cover lid pin is short and does not reach the central thread of the wiring box.
J U N C T I O N B O X E S a c c e s s o r i e s
60
V 68
The pin can be shortened to the required length. Attached ruler is used to measure the spacing of 71 mm when mounting devices in the combined frame. Notches can be used as a gauge to identify cable sections. 1 piece contains a plate of 6 adjusting pins.
- cover
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
V 68
HA
to finally cover the boxes with fixing spacing of 60 mm using fastening screws
To cover the boxes with fixing spacing of 60 mm using fastening screws. For boxes KP 67, KP 68, KPR 68, KUH 1, KPM 64 and KI 68.
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
100; 400 8595057600577
VKP 64/2L
1
- cover
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
VKP 64/2L
HB
for boxes KP 64/2, KP 64/2L
10; 450
8595057655164
To finally cover two boxes or double boxes with a spacing of 71 mm.
J U N C T I O N
V 100 E; V 110 L; KO 100 V; KO 125 V; V 125/1; KT 250 V; VKT 250/L
PVC
-5 - +60°C
item
850°C
A1 - F
- cover
30 sec.
conf.
description
EAN pcs
V 100 E
HB
for boxes KO 100 E
10; 100
V 110 L
HB
for boxes KO 110/L
10; 120
8595057612129
KO 100 V
HB
for boxes KO 100
10; 130
8595057600515
KO 125 V
HB
for boxes KO 125
10; 130
8595057600522
V 125/1
HB
for boxes KO 125 E and KO 125/1L
10; 180
8595057668669
KT 250 V
HB
for boxes KT 250
5; 35
8595057600553
VKT 250/L
HB
for boxes KT 250/1 and KT 250/L
5; 45
8595057669147
V 125/1
Color - white.
8595057617353
B O X E S a c c e s s o r i e s
Mounting screws must be purchased separately.
KT 250 V
VKT 250/L
V 100 E
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
V 110 L
61
1
ZV 68; ZV 97
- blind cover
PE
-30 - +70°C
item
conf.
description
EAN pcs
ZV 68
AB
for boxes of series KU, KP 68, KBV-1
10; 400
8595057600591
ZV 97
AB
for boxes of series KO, KR 97
10; 220
8595057600607
ZV 68
ZV 97
VLK 80
- cover
To cover boxes before rough casting; after plaster solidifies, lid is removed. Color - orange.
J U N C T I O N B O X E S a c c e s s o r i e s
62
PVC
-5 - +60°C
item
850°C
30 sec.
conf.
description
EAN pcs
VLK 80
HB
packed in shrink film
10; 340
To finally cover trunking boxes LK 80/1, 2, 3, and LK 80X28/1. Screws are not included.
material
temperature resistance
self-snuffing
fire class
flaming loop test
halogen-free material
package
8595057616417
VLK 80/R
1
- cover
PVC
-5 - +60°C
item
850°C
30 sec.
conf.
description
EAN pcs
VLK 80/R
VLK 80/2R
HB
packed in shrink film
10; 380
8595057616325
To finally cover trunking boxes LK 80/1, 2, 3 and LK 80X20R/1, LK 80X28R/1, LK 80X28 2R.
J U N C T I O N
- cover
PVC
-5 - +60°C
850°C
item
30 sec.
conf.
description
EAN pcs
VLK 80/2R
VLK 80/T
HB
packed in shrink film
10; 560
8595057614451
To finally cover trunking boxes LK 80X28 2R when mounting double-socket.
- cover
PVC
-5 - +60°C
item
850°C
30 sec.
conf.
description
EAN pcs
VLK 80/T
HB
packed in shrink film
10; 420
B O X E S a c c e s s o r i e s
8595057610880
To finally cover trunking boxes LK 80X16 T and LK 80X28 T.
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
63
1
NR 80/R
- extending frame
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
NR 80/R
J U N C T I O N
NRT
HB
packed in shrink film
10; 240
8595057615823
For trunking boxes LK 80R/1, LK 80R/2, LK 80R/3, LK 80X20R/1, LK 80X28R/1. For trunking boxes for devices of Classic or Swing series.
- extending frame
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
B O X E S a c c e s s o r i e s
NRT
NR 2ZT
HB
10; 300
8595057615755
For trunking boxes LK 80X16 T and LK 80X28 T. For trunking boxes for devices of Tango series.
- extending frame
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
NR 2ZT
64
packed in shrink film
HB
packed in shrink film
10; 200
For trunking boxes LK 80X28 2ZT under the Tango double-socket.
material
temperature resistance
self-snuffing
fire class
flaming loop test
for mounting and double-socket
package
8595057615779
NR 68/6; NR 68/10
1
- extending frame
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
71
conf.
description
EAN pcs
NR 68/6
ZB
packed in shrink film, height 6 mm
10; 750
8595057619036
NR 68/10
ZB
packed in shrink film, height 10 mm
10; 420
8595057619043
NR 68/6
DR18
For individually mounted boxes KU and KP, whose edge is recessed below the level of plaster or tiles during installation. Can also be used for boxes for combined devices KP 64/2, 3, 4, 5.
NR 68/10
J U N C T I O N
- compensating spacer
PVC
-5 - +60°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
DR18
HB
packed in a PE bag
10; 1800 8595057612570
To increase the spacing between the boxes KP 67/2, KP 67/3 by 10 mm for mounting of devices with individual frames side by side.
DR42
For mounting of devices with individual frames side by side.
- compensating spacer
PVC
-5 - +60°C
item
A1 - F
30 sec.
conf.
description
B O X E S a c c e s s o r i e s
EAN pcs
DR42
HB
packed in a PE bag
250; 500 8595057600508
To increase the spacing between the boxes KP 67X67 by 12 mm (to 83 mm). For mounting of devices with individual frames of Classic, Tango, Swing, Time series by ABB.
material
temperature resistance
self-snuffing
fire class
flaming loop test
spacing when joining boxes
package
65
1
MKU 64
- universal assembly ring
PP
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
MKU 64
J U N C T I O N
MKU 97
HB
10; 770
8595057612600
For boxes KPM 64/LU. For drywall with 12.5 mm or 2x12, 5 double in diameter.
- universal assembly ring
PP
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
B O X E S a c c e s s o r i e s
MKU 97
P 110 L
10; 300
8595057612631
For boxes KOM 97/LU. For drywall with 12.5 mm or 2x12, 5 double in diameter.
- partition wall
PVC
-5 - +60°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
P 110 L
66
HB
HB
color - white
Removable partition for box KO 110/L to separate wiring circuits of up to 400 V.
material
temperature resistance
self-snuffing
fire class
flaming loop test
package
10; 600
8595057612136
PI 80R; PI 80T; PI 80 2ZK; PI 80 2ZT
1
- thermo-isolating pad
CEMVIN -5 - +60°C
item
conf.
description
EAN pcs
PI 80R
XX
for boxes LK 80/…, LK 80X28/1, LK 80R/…, LK 80X...R/1, LK 80X28 2R
10; 40
8595057614697
PI 80T
XX
for boxes LK 80X16 T, LK 80X28 T
10; 40
8595057614703
PI 80 2ZK
XX
for boxes LK 80X28 2ZK
10; 40
8595057614727
XX
for boxes LK 80X28 2ZT, box LK 80X28 2T, two pads must be used and adjusted by trimming to the required size
10; 40
8595057614710
PI 80 2ZT
Asbestos-free, harmless material. The pad increases the thermal resistance when installing wiring boxes on flammable surfaces. Corresponds to the shape of wiring box and devices.
J U N C T I O N
Fixing screws item
conf.
description
EAN pcs
2.9X13V
ZNCR for mounting boxes KU, KP, semicircular head with cross groove
50; 4000 8595057619371
2.9X13Z
ZNCR for mounting boxes V 68, countersunk head with cross groove
50; 4000 8595057619388
2.9X16
ZNCR for mounting terminal plates S-66, S-96, SP-96
50; 3000 8595057619395
2.9X22
ZNCR for mounting extension frames NRT, NR 2ZT, NR 80/R
50; 2500 8595057619401
3.0X16
ZNCR for mounting devices into wiring boxes into concrete
50; 3000 8595057619418
M3X40-3CH
for mounting boxes into hollow walls, triple thread significantly ZNCR accelerates the mounting of box
50; 1000 8595057651470
M3X45-3CH
ZNCR
for mounting hollow wall boxes KPR 68/L, KO 97/L, KR 97/L, triple thread significantly accelerates the mounting of boxes
MP3-3CH
ZNCR
foot for mounting hollow wall boxes, triple thread significantly accele50; 3000 8595057651494 rates the mounting of box, foot shape ensures a firm fit in drywall
material temperature resistance
Fixing material (wood screws) used in wiring boxes.
50; 1000 8595057651487
B O X E S a c c e s s o r i e s
package
67
1
S-66
- terminal plate
PA
-30 - +105°C 850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
S-66
J U N C T I O N
S-96
10; 160
8595057614734
Four separate fields for connecting up to three conductors of up to 4 mm2 in diameter. For voltages of up to 400 V.
- terminal plate
-30 - +105°C 850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
S-96
SP-96
p l a t e s
68
packed in shrink film
Intended into distribution boxes with fixing spacing of 60 mm e.g. KU 68, LK ... etc.).
PA
B O X E S t e r m i n a l
FB
FB
packed in shrink film
10; 120
8595057614741
Intended into distribution boxes with fixing spacing of 86 mm (KR 97, KR 97/5, KR 97/L). Four separate fields for connecting up to four conductors of up to 4 mm2 in diameter. For voltages of up to 500 V.
- terminal plate
PA
-30 - +105°C 850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
SP-96
FB
packed in shrink film
10; 180
Intended into distribution boxes with fixing spacing of 86 mm (KR 97, KR 97/5, KR 97/L). Five separate fields for connecting up to four conductors of up to 4 mm2 in diameter. For voltages of up to 500 V.
material
temperature resistance
self-snuffing
fire class
flaming loop test
halogen-free material
package
8595057614758
6303-...
1
- terminal plate
PA
-30 - +105°C 850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
6303-11
FB
packed loosely in cardboard, intended for metal boxes 7116 and 7216
12
8595057644953
6303-12
FB
packed loosely in cardboard, intended for metal boxes 7121 and 7221
12
8595057644960
TYP...
6303-11: four separate fields for connecting up to 2x three and 2x four conductors of up to 4 mm2. 6303-12: four separate fields for connecting up to five conductors of up to 4 mm2. For voltages of up to 500 V. When used with terminal plate with box with protective terminal, ground connection must be removed.
J U N C T I O N
- mutlipolar terminal plate
PA
-40 - +100°C 850°C
item
TYP210 TYP310 TYP412 TYP512 TYP612
material fire class
A1 - F
30 sec.
conf.
description
FA
packed in cardboard, color - black
HA
packed in cardboard, color - white
FA
packed in cardboard, color - black
HA
packed in cardboard, color - white
FA
packed in cardboard, color - black
HA
packed in cardboard, color - white
FA
packed in cardboard, color - black
HA
packed in cardboard, color - white
FA
packed in cardboard, color - black
HA
packed in cardboard, color - white
EAN mm
pcs
mm2
A
12 x 16 x 95
12
2,5
24
17 x 18 x 107
12
4
32
17 x 19 x 119
12
6
41
21 x 21 x 142
12
10
57
22 x 22 x 154
12
16
76
pcs
100
8595057613539
100
8595057614321
100
8595057613553
100
8595057614345
100
8595057613577
100
8595057614369
100
8595057613591
100
8595057614383
50
8595057613607
100
8595057614390
For voltages of up to 500 V.
temperature resistance flaming loop test
self-snuffing
B O X E S t e r m i n a l p l a t e s
dimensions - width, height, depth 2
number of conductors x diameter (mm ), load-current capacity: (A)
package
69
1
TYP...
- screwless terminal plate
PA
-40 - +100°C 850°C
item
J U N C T I O N
EAN pcs
mm2
pcs
XX
5
1,0 - 2,5
100
8595057613614
XX
3
1,0 - 2,5
100
8595057613621
TYP017
XX
2
1,0 - 2,5
100
8595057613638
TYP018
XX
4
1,0 - 2,5
100
8595057613645
Maximum working load of 24 A. Terminals are intended for full Cu conductors. For wires with cross-section from 1.0 mm2 to 2.5 mm2. For voltages of up to 450 V. Colour-coding stripe.
- equipotential terminal plate
-30 - +105°C 850°C
item
A1 - F
30 sec.
conf.
description
XX
without cover
X1
with cover
EAN
EPS 2
EPS 3
p l a t e s
mm2
pcs
4 6 2 1
2,5 - 6 4 - 16 10 - 95 30 x 4 (belt)
1
8595057618374
1
8595057687806
Bonding. Use only for bonding the zero potential, cannot be used as a phase connection etc. Can be used in the box KO 125 E - the box is specially adapted for mounting. Possibility to install also in boxes KT 250/1 and KT 250/L.
- equipotential terminal plate
-30 - +105°C 850°C
item
EPS 3
fire class
pcs
Used for main connection according to ČSN 1-35 2000-4-41.
PP
material
70
conf.
TYP016
PP
B O X E S t e r m i n a l
30 sec.
TYP015
EPS 2
A1 - F
A1 - F
30 sec.
conf.
XX
description
EAN
without cover
pcs
mm2
pcs
8 6
0,75 - 10 1,5 - 16
1
Used for main connection according to ČSN 1-35 2000-4-41. Bonding. Use only for bonding the zero potential, cannot be used as a phase connection etc. Can be used in the box KO 100 E.
temperature resistance flaming loop test
self-snuffing
package 2
number of conductors x diameter (mm ), load-current capacity: (A)
8595057668676
VPTU
item
VPTU
VPT...
conf.
XX
EAN mm
pcs
6
1
8595057616141
In combination with other components, it is used for drill assembly. Minimum diameter of chuck and of drilling machine is 11 mm.
- saw-drill
item
conf.
EAN mm
pcs
VPT 40
XX
40
1
8595057616097
VPT 64
XX
68
1
8595057616103
VPT 68
XX
73,5
1
8595057616110
VPT 79
XX
79,5
1
8595057616127
VPT 97
XX
103,5
1
8595057616134
P1
1
- universal carrier
Designed for precise holes for mounting boxes into hollow walls made of drywall.
J U N C T I O N
Drill size is designed for specific types of boxes.
B O X E S h e l p
- spring
item
conf.
EAN pcs
P1
XX
10
8595057616172
t o o l s ZBU
- recessing edge
item
ZBU
conf.
XX
EAN mm
pcs
79,5 (depth 1,5)
1
8595057621176
To create a countersink for the exact placement of boxes KPM 64/LU, KPR 68/L and KU 68 LA/1HF into drywall.
milled (drilled) hole diameter package
71
1
Parts needed for setting up the drill universal carrier
saw-drill
recessing edge
spring
VPTU
VPT 40 VPT 64 VPT 68 VPT 79 VPT 97
ZBU
P1
X X
B O X E S h e l p
X
KPR 68/L, KPM 64/LU, KU 68 LA/1HF
X
X
KU 68 LD/1, KU 68 LD/2, KUH 1/L, KU 68 LD/1HF, KPR 68/71L
X
X X X
KU 68/71L1 KP 64/LD, KP 64/2L, KP 64/3L, KP 64/4L, KP 64/5L KI 68 L/1, KI 68 L/2
X X
- drill for hollow walls
item
VDS 68
FR 68 SDS
XX
mm
pcs
73,5
1
EAN
parts of configuration
for boxes
8595057658967
VPTU + VPT 68 + P1
KU 68 LD/1, KU 68 LD/2, KUH 1/L, KU 68 LA/1HF, KU 68 LD/1HF
Countersink blade. Minimum diameter of chuck and of drilling machine is 11 mm.
- non-hammered masonry cutter
FR 68 SDS
milled (drilled) hole diameter
conf.
Complete set for the most common wiring boxes.
item
package
KT 250/L, KO 110/L KO 97/L, KR 97/L, KOM 97/LU (HF)
X
VDS 68
X
X X
X
t o o l s
72
X
X
X X X
J U N C T I O N
X
for boxes
conf.
XX
EAN mm
pcs
80
1
8595057615915
Cutter intended for non-impact drilling in brickwork or aerated cement. SDS plus clamping system. For boxes KU 68, KP 68, a KP 64/….
1
KOPOBOX mini B
- the configuration of multi-purpose device box
PC-ABS
-5 - +60°C
850°C
item
A1 - F
30 sec.
IP20
conf.
description
EAN pcs
KOPOBOX mini B
HB
the colour of perspective parts (lid + frame) - white RAL 9003
1
8595568920065
KB
the colour of perspective parts (lid + frame) - light grey RAL 7035
1
8595568920072
The dimension of completed configuration: 175 x 80 x 68 mm. The configuration is intended for assembling to/under parget or to concrete floors. Prior to installation of assembling box there is necessary to insert the distance rail, which is replaced upon the plaster induration. Subgrade assembling box puts down into plaster seam. During the completion the assembling box is subsequently shouldered
J U N C T I O N
by KOPOBOX mini box frame.
It enables the assembling of modular devices of 3 pcs 45x45, or 6 pcs 22,5x45 or their combination.
It is suitable for devices of following manufacturers: Legrand, ABB, PEHA, Simon Connect, Schneider Electric.
Max. load: 1000 N to total surface of cover (lid + frame).
B O X E S m u l t i p u r p o s e
KOPOBOX mini L
PC-ABS
-5 - +60°C
850°C
item
A1 - F
30 sec.
IP20
conf.
description
EAN pcs
KOPOBOX mini L
HB
the colour of perspective parts (lid + frame) - white RAL 9003
1
8595568920041
KB
the colour of perspective parts (lid + frame) - light grey RAL 7035
1
8595568920058
N1B
the colour of perspective parts (lid + frame) - titanium, upon request
1
8595568921895
The dimension of completed configuration: 175 x 80 x 75 mm. The configuration is intended for assembling to furniture, into the hollow walls or to double floors. Box KOPOBOX mini L there is possible to assemble to the thickness of the desks from 9 till 38 mm. Fast assembling by help of fixation lugs. The bottom cover box enables the fixation of cables against their rapture.
KOPOBOX mini L enables the assembling of modular devices of 3 pcs 45x45 or 6 pcs 22,5x45 or their combination.
b o x
74
- the configuration of multi-purpose device box
It is suitable for devices of following manufacturers: Legrand, ABB, PEHA, Simon Connect, Schneider Electric.
material
temperature resistance
self-snuffing
IP classification
fire class
flaming loop test
halogen-free material
package
KOPOBOX mini P
1
- the configuration of multi-purpose device box
PC-ABS
-5 - +60°C
850°C
item
A1 - F
30 sec.
IP20
conf.
description
EAN pcs
KOPOBOX mini P
HB
the colour of perspective parts (lid + frame) - white RAL 9003
1
8595568920089
The dimension of completed configuration: 175 x 80 x 50 mm. The configuration is intended for assembling into the parapet trunkings PK 110X70 D and PK 110X70 D HF. The bottom cover box enables the fixation of cables against their rapture. KOPOBOX mini L enables the assembling of modular devices of 3 pcs 45x45 or 6 pcs 22,5x45 or their combination. It is suitable for devices of following manufacturers: Legrand, ABB, PEHA, Simon Connect, Schneider Electric.
J U N C T I O N B O X E S m u l t i p u r p o s e b o x
material
temperature resistance
self-snuffing
IP classification
fire class
flaming loop test
halogen-free material
package
75
1
Using floor boxes in and concrete floor instrument underlay PP 80/3
floor box frame KOPOBOX 57
instrument underlay PP 80/45
instrument box KPP 80
floor box frame KOPOBOX 80
W I R I N G
floor box KUP 80
floor box KUP 57 KUP 80 floor box KUP 57 KUP 80
KOPOBOX 57 - set
KOPOBOX 80 - set leveling set SN
The complete set of and floor box composed of KOPOBOX 57 and KUP 57 or KUP 80 is designated for the assembly of the modular devices 45 x 45 mm. The mounting feet (designed for doubled floors) are not used during the installation of the box KOPOBOX 57 into KUP.
The complete set of the floor box composed of KOPOBOX 80 and KUP 80 is designated for the installation of classic and also modular devices. The selection of the type of devices being installed is given by the type of the devices underlay. The mounting feet (designed for doubled floors) are not used during the installation of the box KOPOBOX 80 into KUP 80.
Instructions for the assembly of KOPOBOX 57: Installation box KUP 57 is suitable for the concrete layers from 57 mm up to 75 mm, KUP 80 is suitable for the concrete layers from 80 up to 95 mm. There is necessary to fix the installation box on the background surface. The height of the box can be adjusted by raising of insertion in range from 57 up to 75 mm (KUP 57) or from 80 up to 95 mm (KUP 80) with screws.
Instructions for the assembly of KOPOBOX 80: Installation box KUP 80 is suitable for the concrete layers from 80 mm up to 95 mm. There is necessary to fix the installation box on the background surface. The height of the box can be adjusted by raising of insertion in range from 80 up to 95 mm with screws.
In case of concrete layer higher than 75 mm (KUP 57) or 95 mm (KUP 80) is necessary to use and levelling set SN (4 pcs) anchored to the surface. The levelling set enables to adjust the height of the box by 35 mm.
In case of concrete layer higher than 95 mm there is necessary to use and levelling set SN (4 pcs) anchored to the surface. The levelling set enables to adjust the height of the box by 35 mm.
The box is adapted for the installation of electrical pipes. Every single input together with raising insertion for height setting must be sealed to avoid breaking the concrete into the box.
KUP 80 is adapted for the installation of electrical pipes. Every single input together with raising insertion for height setting must be sealed to avoid breaking the concrete into the box.
During placement of concrete it is necessary to use and cover board (included KUP) to prevent the box from being filled with concrete. After the concrete mix hardens and the cover board is removed the floor box KUP is fitted with and frame of the floor box KOPOBOX 57. There are then installed the holders of the devices into the frame and there is performed the electrical installation of the modular devices.
During placement of concrete it is necessary to use and cover board (included KUP 80) to prevent the box from being filled with concrete. After the concrete mix hardens and the cover board is removed the floor box KUP 80 is fitted with and frame of the floor box KOPOBOX 80. Subsequently the instrument boxes KPP 80 are inserted to the frame. On the base of installed apparatus, PP 80 instrument underlay should be used.
KOPOBOX 57 is mainly designed for cables with direct plugs. Use of cables with indirect plugs is limited. Use of adapters and chargers is limited by their size.
Modular devices: - installation into KPP 80 + PP 80/45, - installation directly on PP 80/45, while using the cross-piece PKUP. Classic devices: - installation into KPP 80 + PP 80/3 for the non-fitted assembly openings use the end cap ZPP.
The cover of the frame is determined for floor covering with highest layer of 7 mm. Considering IP, the box is not suitable to be moistened with the floor cleaning machines. Recommended floor covering are carpets or floating wooden floors. To the system is possible assembly modular instrument from companies ABB, PEHA, Legrand, OBO Bettermann and other same design. Floor boxes KOPOBOX are designed for a maximum load of 1500 N.
KOPOBOX 80 is mainly designed for cables with indirect plugs. Use of cables with direct plugs is limited and use of adapters and chargers is limited. The cover of the frame is determined for floor covering with highest layer of 7 mm. Considering IP, the box is not suitable to be moistened with the floor cleaning machines. Recommended floor covering are carpets or floating wooden floors.
B O X E S i n t o c o n c r e t e f l o o r s
To the system is possible assembly modular instrument from companies ABB, PEHA, Legrand, OBO Bettermann and other same design. Floor boxes KOPOBOX are designed for a maximum load of 1500 N.
77
1
KOPOBOX 57
- floor box frame
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
IP30
conf.
description
EAN pcs
KOPOBOX 57
LB
color - dark grey
1
8595057690721
Designed for installation into the universal floor box KUP 57 or KUP 80. Allows the assembly of modular devices 45 x 45 mm (max. 6 pcs) from ABB, PEHA, Legrand and OBO Bettermann. Reinforcement of the lid by sheet metal ensures its high mechanical strength while maintaining the possibility to insert the final floor covering. The lid has 2 tilt flaps enabling the outlet of the cables from the box.
W I R I N G B O X E S i n t o
KOPOBOX comes in dark grey as a standard. For orders over 500 pieces we can supply different RAL colour (except for actual device carriers).
KOPOBOX 80
c o n c r e t e
The frame is separately applied for double floors with a thickness of 10-40 mm.
- floor box frame
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
IP30
conf.
description
EAN pcs
KOPOBOX 80
LB
color - dark grey
1
8595057690738
Designed for installation into the universal floor box KUP 80. Using device boxes KPP 80 (max. 2 pcs) with the device pads PP 80/3 enables the mounting of standard devices (max. 6 pcs), with the pads PP 80/45 it enables the mounting of modular devices (max. 8 pcs).
Reinforcement of the lid by sheet metal ensures its high mechanical strength while maintaining the possibility to insert the final floor covering. The lid has 2 tilt flaps enabling the outlet of the cables from the box.
Included are screws for attaching the frame to the floor box KUP. KOPOBOX comes in dark grey as a standard. For orders over 500 pieces we can supply different RAL colour (except for actual
f l o o r s
78
Included are screws for attaching the frame to the floor box KUP.
device carriers).
The frame is separately applied for double floors with a thickness of 10-40 mm.
material
temperature resistance
self-snuffing
IP classification
fire class
flaming loop test
halogen-free material
package
PP 80/K-5
1
- pulling floor box
PA
-5 - +105°C
850°C
item
A1 - F
30 sec.
IP30
conf.
description
EAN pcs
PP 80/K-5
KUP 57
LB
color - dark grey
1
8595057699571
Designed for installation into the floor box KUP 80. Use as a blind cover for threading cables. After frame installation, put the final flooring on support sheet metal; the frame is not designed for device installation.
W I R I N G
Additional device installation is possible only when you change the frame on KOPOBOX 80.
B O X E S i n t o
- universal floor box
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KUP 57
FB
color - dark grey
1
8595057690745
After hardening of the concrete mixture, floor box KOPOBOX 57 is fitted. The package includes a cover plate to prevent the box from being poured over with concrete. The minimum height of the concrete layer is 57 mm, maximum 75 mm. The desired height of the box is adjusted by raising the
c o n c r e t e
internal insert using screws in the corners of the box.
For a concrete layer higher than 75 mm, it is necessary to use a levelling set SN (4 pcs). The box is designed for the installation of el. pipes, passages can be created with a progressive drill (pg. 1-93).
material
temperature resistance
self-snuffing
IP classification
fire class
flaming loop test
halogen-free material
package
f l o o r s
79
1
KUP 80
- universal floor box
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
KUP 80
FB
color - dark grey
1
8595057690752
After hardening of the concrete mixture, floor box KOPOBOX 57 or KOPOBOX 80 is fitted. The package includes a cover plate to prevent the box from being poured over with concrete. The minimum height of the concrete layer is 80 mm, maximum 95 mm. The desired height of the box is adjusted by raising the internal insert using screws in the corners of the box.
W I R I N G B O X E S i n t o
KPP 80
c o n c r e t e
For a concrete layer higher than 75 mm, it is necessary to use a levelling set SN (4 pcs). The box is designed for the installation of el. pipes, passages can be created with a progressive drill (pg. 1-93).
- instrument floor box
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
KPP 80
LB
color - dark grey
1
Universal device box for mounting into KOPOBOX 80 (max. 2 pcs). Device screws, cable link screws and cable fixing links are included. Depth of the box is adjustable by changing the position of the bottom.
f l o o r s
80
EAN pcs
material
temperature resistance
self-snuffing
fire class
flaming loop test
halogen-free material
package
8595057690769
PP 80/...
1
- instrument underlay
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
PP 80/0
LB
full plate for covering the unoccupied parts of KOPOBOX
1; 100
8595057690783
PP 80/3
LB
plate for mounting up to 3 pcs of standard devices
1; 100
8595057690790
LB
plate for mounting up to 4 pcs of modular devices from ABB, PEHA and OBO Bettermann
1; 100
8595057690806
PP 80/45
ZPP
Device plate is installed into the floor box KOPOBOX 80 frame.
W I R I N G
Installation is recommended together with the device box KPP 80. When installing multiple modular devices, it is appropriate to remove the inner partition. External dimensions of other device pads are identical with the drawing.
B O X E S i n t o
- end cap
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
ZPP
LB
color - dark grey
1; 1800
To blind vacant holes on the device pad PP 80/3.
8595057690820
c o n c r e t e f l o o r s
material
temperature resistance
self-snuffing
fire class
flaming loop test
halogen-free material
package
81
1
PKUP
- partition wall
PA
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
PKUP
LB
color - dark grey
1; 480
8595057690837
To divide the interior of KOPOBOX 80. Useful when installing modular instruments in the instrument supports PP 80/45 if boxes KPP 80 are not used.
W I R I N G B O X E S i n t o
SN
c o n c r e t e
- leveling set
PE
-5 - +105°C
item
850°C
A1 - F
30 sec.
conf.
description
EAN pcs
SN
XX
the package includes 4 pieces - for all corners of the box
1; 90
To set the exact height of the universal box KUP 57 or KUP 80 when pouring into concrete floors. To prevent wash-up with concrete, fix the box using M6 nuts - included in the package. Sold in sets containing 4 adjuster pieces. Groove for screwing allowing comfortable and precise height adjustment.
f l o o r s
82
material
temperature resistance
self-snuffing
for mounting and double-socket
fire class
flaming loop test
spacing when joining boxes
halogen-free material
package
8595057690844
PUK 38X150 S1
1
- floor trunking
item
conf.
description
EAN m
PUK 38X150 S1
SPUK
S
galvanized Sendzimir
2; 240
8595568904416
To connect boxes KUP 57 or KUP 80. Projections for quick and easy channel connection to ensure conductive bonding using PLUK or PLUK 1.
- coupling floor trunking
item
conf.
description
EAN
W I R I N G
pcs
SPUK
PLUK
S
galvanized Sendzimir
1
8595568904423
The overlap joints of floor channels. Prevents ingress of concrete into channels. Attached to the floor with screws or gun nails.
- connecting string
item
conf.
description
EAN pcs
PLUK
XX
length of 250 mm, to connect channels when coming out at an angle of 90°
10
8595568904430
PLUK 1
XX
length of 550 mm, to connect channels when coming out at an angle of 180°
10
8595568904447
Provides a conductive bonding of floor channels.
B O X E S i n t o c o n c r e t e f l o o r s
package
83
1
Boxes built - into concrete
support KBP-1/71 support KBP-1 body KBT-2 pipe 8020 (∅ 20 mm)
bottom KBS-2
body KBT-1
W I R I N G
extending frame NRB 60/12 extending frame NRB 60/24 bottom KBS-3
nut KBM
B O X E S i n t o
84
80
(71
)
girdle for chrandelier hook
rod KBP-8 (∅ 6 mm)
A
high box
X X
B
high box with support
C
low box 80
X
D
low box 80 with support
X
E
low box 71
F
low box 71 with support
G
high chandelier box
H
low chandelier box
X
X
X
X
X
X
8020
V 68 S
KBP-10
KBP-9
KBP-8
KBP1/71
KBP-1
KBS-3
KBS-2
X X
X
X
X
X
X
X
X X
cover V 68 S
X
X X
KBV-2/71
KBV-1 KBV-2
KBT-3/71
Set
KBT-2
cover KBV-2/71 cover KBV-2 cover KBV-1
KBT-1
c o n c r e t e
chandelier hook KBP-10 chandelier hook KBP-9
X
X
X
X
X
X
X
X X X
X X
KBT-1
1
- high body of the box into concrete
PP
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
KBT-1
AB
packed in shrink film, color - orange
10; 100
8595057632455
The body of the box is provided with a fixture for connection to the lid KBV and bottom KBS. The perimeter of the box body contains pre-marked holes to drill inlets for pipes of EN 25 and 32, inlets can easily be made in the desired locations using a drill and the respective drilling blade.
For devices with greater mounting depth. The box can be fitted with terminal plate S-66, we recommend its mounting to the box body before assembly.
W I R I N G
KBT-2
B O X E S i n t o
- low body of the box into concrete
PP
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
KBT-2
AB
packed in shrink film, color - orange
10; 80
8595057632462
The body of the box is provided with a fixture for connection to the lid KBV and bottom KBS. The perimeter of the box body contains pre-marked holes to drill inlets for pipes of EN 20 and 25, inlets can easily be made in the desired locations using a drill and the respective drilling blade.
The box can be fitted with terminal plate S-66, we recommend its mounting to the box body before assembly.
material
temperature resistance
for mounting and double-socket
fire class
flaming loop test
halogen-free material
c o n c r e t e
package
85
1
KBT-3/71
- low box into and concrete
PP
-5 - +60(90)°C 650°C
item
A1
71
conf.
description
EAN pcs
KBT-3/71
AB
packed in shrink film, color - orange
10; 100
8595057667853
Designed for connection with lid KBV-2/71. For devices in the combined frames with 71 mm spacing. Inlets for pipes of EN 20 or EN 25 can be easily made using drill VBU1 and the respective drilling blade. The design of the bottom allows inserting a pipe of diameter 20 allowing interconnection of boxes.
W I R I N G B O X E S i n t o
KBS-2
- bottom of the box into concrete
PP
-5 - +60(90)°C 650°C
item
c o n c r e t e
86
A1
conf.
description
EAN pcs
KBS-2
AB
packed in shrink film, color - orange
10; 240
The bottom is suitable for covering the bodies of boxes KBT-1 and KBT-2. The design of the bottom allows the insertion of a pipe of 20 mm in diameter. The inserted pipe can be used to interconnect the boxes.
material
temperature resistance
spacing when joining boxes
fire class
flaming loop test
halogen-free material
package
8595057632516
KBS-3
1
- bottom of the box into concrete
PA
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
KBS-3
AB
packed in shrink film, color - orange
10; 200
8595057608146
The bottom is suitable for covering the bodies of boxes KBT-1 and KBT-2. The design of the bottom allows the insertion of KBM nut for screwing the threaded hook eye. The nut must be inserted before pouring concrete over the assembly!
W I R I N G
KBV-1
B O X E S i n t o
- cover of the box into concrete
PP
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
KBV-1
KB
packed in shrink film, color - light grey
10; 140
8595057632509
The lid can be attached to the formwork using nails. After hardening of the concrete, remove part of the rip-out part of the lid, making space for mounting. When applying additional stucco, blind cover ZV 68 can be used to cover it.
To adjust the height when applying additional plaster, you can use extending frame NR 68/6, NR 68/10 or NRB 60/12 and NRB 60/24.
material
temperature resistance
spacing when joining boxes
halogen-free material
fire class
flaming loop test
for mounting and double-socket
package
c o n c r e t e
87
1
KBV-2...
- cover of the box into concrete
PP
-5 - +60(90)°C 650°C
item
A1
KBV-2/71 - 71
conf.
description
EAN pcs
KBV-2
KB
packed in shrink film, color - light grey
10; 160
8595057632486
KBV-2/71
KB
for devices in the combined frames with 71 mm spacing
10; 200
8595057632493
The lid can be attached to the formwork using nails. After hardening of the concrete, remove part of the rip-out part of the lid, making space for mounting. When applying additional stucco, blind cover ZV 68 can be used to cover it. To adjust the height when applying additional plaster, you can use extending frame NR 68/6 or NR 68/10.
W I R I N G B O X E S i n t o
KBV-3
- cover of the box into concrete
PP
-5 - +60(90)°C 650°C
item
c o n c r e t e
88
A1
conf.
description
EAN pcs
KBV-3
KB
packed in shrink film, color - light grey
10; 120
8595057657151
Designed for installation in concrete partition walls with 100 mm thickness - in conjunction with KBT-1 and KBV-1 (KBV-2). Designed for installation in concrete partition walls with 80 mm thickness - in conjunction with KBT-2 and KBV-1 (KBV-2).
material
temperature resistance
spacing when joining boxes
halogen-free material
fire class
flaming loop test
for mounting and double-socket
package
KBP-1...
1
- support of the box into concrete
PE
-5 - +60(90)°C 650°C
item
KBP-1/71 - 71
A1
conf.
description
EAN pcs
KBP-1
AA
packed in shrink film, color - orange
10; 150
8595057608115
KBP-1/71
AB
for devices in the combined frames with 71 mm spacing
10; 220
8595057624252
Use the support to fix the boxes between the formwork walls.
W I R I N G
NRB 60...
B O X E S i n t o
- extending frame do betonu
PE
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
NRB 60/12
AB
packed in bags of 10 pieces
10; 340
8595057616455
NRB 60/24
AB
packed in bags of 10 pieces
10; 160
8595057616462
To adjust the box height when applying plaster.
material
temperature resistance
spacing when joining boxes
fire class
flaming loop test
halogen-free material
c o n c r e t e
package
89
1
KBE-1
- spacer into concrete
PE
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
KBE-1
AB
packed in shrink film, color - orange
10; 2420 8595057614475
To increase and maintain the 88 mm spacing between boxes. For mounting devices with individual frames, according to device type, a gap remains between the installed devices.
W I R I N G B O X E S i n t o
KBS-120
- spacer into concrete
PE
-5 - +60(90)°C 650°C
item
c o n c r e t e
90
A1
conf.
description
EAN pcs
KBS-120
AB
packed in shrink film, color - orange
For outlet of multiple piping into one place (e.g. at the location of future distribution systems). Box cover is fixed to the formwork using nails or screws. After solidification, remove the front rip-out part of the lid.
material
temperature resistance
halogen-free material
fire class
flaming loop test
package
10; 70
8595057624269
KBP-8
1
- steel rod
steel
3000
item
conf.
description
EAN m
KBP-8
ZA
steel rod ∅ 6 mm
3
8595057610231
To bracing the boxes between formwork walls when pouring concrete. Use together with lids and supports - see assembly diagrams. The rod must be cut to length - determining the length is specified for each assembly.
KBP-9; KBP-10
W I R I N G
- chandelier hook with nut and girdle
steel
item
conf.
description
EAN pcs
KBP-9
XX
length of 100 mm, for assembly with box body KBT-2
40; 80
8595057610378
KBP-10
XX
length of 118 mm, for assembly with box body KBT-1
40; 80
8595057610361
KBM
Hook capacity of 250 N (25 kg). The hook should be fitted with an insulating sleeve made of PVC (included). Nut included.
- nut for chandelier hook
brass
item
conf.
description
EAN pcs
KBM
material délka
XX
40; 200
B O X E S i n t o c o n c r e t e
8595057626669
Brass nut with thread M5, designed for KBS-3 for subsequent mounting of the hook, can be used for KBP-9 and KBP-10. The nut should be inserted in the bottom of the box KBS-3 before pouring concrete!
package
91
1
V 68 S
- cover
PVC
-5 - +60(90)°C 850°C
item
A1 - F
30 sec.
conf.
description
EAN pcs
V 68 S
W I R I N G
BV...
c o n c r e t e
10; 120
8595057650541
It provides IP 20 protection. Two holes allow threading the light inlet and installation of the hook. Fixing with screws 2.9 x 13 (not included).
- bushing for pipes
-5 - +60(90)°C 650°C
item
A1
conf.
description
EAN pcs
BV 1620
KA
for dimensioned pipes EN 16, 20
40; 560
8595057621985
BV 2532
KA
for dimensioned pipes EN 25, 32 and ČSN 16, 23
40; 280
8595057621992
BK...
The glands are fixed to the formwork using nails. After hardening of the concrete mixture, formwork is removed together with front lid. To introduce the pipe, use BK-type fittings as per pipe dimension: BV 1620 - fittings BK 16, BK 20 BV 2532 - fittings BK 25, BK 32, BK 16 CSN, BK 23
- ending for pipes
PE
-5 - +60(90)°C 650°C
item
A1
conf.
description
A
B
C
mm
mm
mm
pcs
EAN
BK 16
AA
for dimensioned pipes EN 16
19
38
27
40; 600
8595057621688
BK 16 ČSN
AA
for dimensioned pipes ČSN 16
24
38
40
40; 320
8595057629165
BK 20
AA
for dimensioned pipes EN 20
23
38
27
40; 560
8595057621718
BK 23
AA
for dimensioned pipes ČSN 23
30
38
40
40; 280
8595057629158
BK 25
AA
for dimensioned pipes EN 25
28
38
40
40; 320
8595057621701
BK 32
AA
for dimensioned pipes EN 32
35
38
40
40; 320
8595057621695
92
packed in shrink film in packages of 10 pieces
For closing the box with the hook.
PP
B O X E S i n t o
HB
For insertion of pipes LPE-1 into the BV glands ...
material
temperature resistance
self-snuffing
fire class
flaming loop test
halogen-free material
package
VBU 1 VB ČSN; VB EN
1
- drill - drilling edge
item
conf.
EAN pcs
VBU 1
XX
1
8595057627123
VB ČSN
XX
1
8595057627130
VB EN
XX
1
8595057627147
For making holes in the pipe dimensions in wiring boxes into cast concrete
The tang is used to insert drilling blades.
- PG 13,5; 16 and 23 mm - EN 16; 20; 25 mm
W I R I N G
The KBV cover fixed to boarding.
Example of usage the busing and ending.
package
Flexible pipes installed into KBT body.
Example of usage for horizontal boarding.
The KBT... box with terminated conductor ready for mounting the KBP... chandelier hook.
Sealing the penetrations (mastic).
The KBT... box covered with the V 68 S cover with terminated conductor and KBP... chandelier hook.
B O X E S i n t o c o n c r e t e
93
1
Way of using the concrete program and determining the lengths of individual spacer components The set is designated for cast concrete constructions and enables subsequent assembly of all available appliances (sockets, switches). The axial distance of the used appliances is 80 mm (Klasik) or 71 mm (Tango), spacer KBE-1 allows increasing spacing of 80 mm to 88 mm. Components marked with the type number …/71 are designated for appliances with the common frame with spacing of 71 mm (Tango).
Fig. 1
Basic usage to spacing of 80 or 88 mm
pipe 8020 (∅20 mm) B1
rod KBP-8 (∅6 mm) - A1
bottom KBS-2
cover KBV-2
body KBT-2
Fig. 1A
W I R I N G
support KBP-1
Fig. 1B
spacer KBE-1
cover KBV-1
B O X E S i n t o c o n c r e t e
pipe 8020 (∅20 mm) - B2
Fig. 2
rod KBP-8 (∅6 mm) A1
body KBT-1
Fig. 1A Minimum height of the set while using the element KBT-2 (L): L = 90 mm Length of spacing rods: A1 = L - 20 mm Length of spacing pipe 8020: B1 = L - 65 mm Fig. 1B Minimum height of the set while using the element KBT-1 (L): L = 110 mm Length of spacing rods: A1 = L - 20 mm Length of spacing pipe 8020: B2 = L - 85 mm
Example of assembly to spacing 80 mm bottom KBS-2
pipe 8020 (∅20 mm) - B
cover KBV-2 body KBT-2
cover KBV-2
body KBT-2
bottom KBS-2
rod KBP-8 (∅6 mm) A
frame NRB 60/12 frame NRB 60/24
Cover KBV-2 is mounted to the fixed part of the casing. Then body KBT-1 (KBT-2) is assembled together with the bottom piece KBS-2 and pushed to the already fixed cover KBV. The other box is assembled, pipe 8020 is inserted as well as rod KBP-8. The back part of the set assembled in this way is slipped over the already mounted box and cover.
Minimum height of the set while using the element: KBT-2 L2 = 140 mm KBT-1 L1 = 185 mm Length of spacing rod while using the element: KBT-2 A = L2 - 10 mm KBT-1 A = L1 - 10 mm Length of spacing pipe 8020 while using the element: KBT-2 B = L2 - 112 mm KBT-1 B = L1 - 152 mm
Example of using the top lighting hook to the horizontal casing bottom KBS-3
body KBT-1 body KBT-2
cover KBV-2 cover KBV-1
nut KBM cover V 68 S girdle for chrandelier hook
94
Cover KBV-1 (KBV-2) is mounted to the fixed part of the casing. Then body KBT-1 (KBT-2) is assembled together with the bottom piece KBS-2 and pushed to the already fixed cover KBV. Spacing pipe 8020 is inserted to support KBP-1 as well as the rod KBP-8. The back part of the set assembled in this way is slipped over the already mounted box and cover. KBV-1 cover can be applied for assembly of and double socket. The system can be completed from the side of the support KBP-1 which is mounted to the fixed part of the casing.
chandelier hook KBP-10 chandelier hook KBP-9
Cover KBV-1 (KBV-2) is mounted to the fixed horizontal part of the casing. Then body KBT-1 (KBT-2) is assembled and toget her with the base part KBS-3 it is pushed to the already fixed cover. Before pouring the concrete mix to the set of the bottom piece KBS-3, insert the nut KMB.
Fig. 4
Example of assembly to spacing 71 mm pipe 8020 (∅20 mm) - B
Fig. 4A
support KBP-1/71
cover KBV-2/71
body KBT-3/71
The cover KBV-2/71 will be attached to and firm part of and boarding. The body KBT-3/71 will be pressed into and cover KBV-2/71 having been fixed before. We will assembly the other box completely (see picture 4B), push and distance pipe 8020 and four distance bars KBP-8. The back part of and set assembled in this way will be slipped onto and mounted box and cover. The collar NBR is used to adjust the height of and box during subsequent application of and plaster. The system may be assembled from the side of and support KBP-1/71, which we fix on the firm part of and boarding.
rod KBP-8 (∅6 mm) A pipe 8020 (∅20 mm) - B
cover KBV-2/71
body KBT-3/71
Fig. 4B
Fig. 4A Minimum height of the set while using the element KBT-3/71 (L): L = 80 mm Length of spacing rods: A = L - 20 mm Length of spacing pipe 8020: B = L - 65 mm Fig. 4B Minimum height of the set while using the element KBT-1 (L): L = 125 mm Length of spacing rods: A = L - 10 mm Length of spacing pipe 8020: B = L - 110 mm
cover KBV-2/71 body KBT-3/71
Fig. 5 cover KBV-2 cover KBV-1
1
rod KBP-8 (∅6 mm) A
frame NRB 60/12 frame NRB 60/24
Example of the KBV-3 cover usage body KBT-1 body KBT-2 cover KBV-3
The KBV-3 cover is suitable when both sides of the wall shall be fitted with electronic devices against each other. The cover is designed for mounting together with KBT-1 or KBT-2 box and the KBV-1 or KBV-2 cover. The cover allows to install the double-socket as well with the KBV-1 cover.
Height of the set when using the body (wall width): KBT-1 L1 = 100 mm KBT-2 L2 = 80 mm
W I R I N G B O X E S i n t o c o n c r e t e
For all way of using the set to the cast concrete it is necessary: Before pouring concrete mixture, we recommend tying the system to reinforcements by means of draw bands (see page 4-8) and sealing passages around tubes using sealing material. When the concrete mix is mature and the casing is dismantled, the break-off bottom of the cover KBV is removed and final electrical wiring is made inside the KBT boxes, or the top lighting hook of required length is inserted.
95
WIRING TRUNKINGS AND ACCESSORIES
2
Wiring trunkings and accessories Produced in compliance with ČSN EN 50 085-1 (ČSN 37 0100) and further applicable standards, specifications, and approved documentation. Used material: hard self-snuffing polyvinyl chloride (PVC) with temperature resistance from -5 °C to +60 °C. The trunkings passed the resistance test to spread of flame in compliance with ČSN EN 50 085-1 §12.1. and ČSN 33 2312 čl. 2.10. KOPOS KOLÍN a.s. as the manufacturer recommends installing on and into construction materials with fire classes A1 to F according to ČSN EN 13 501-1. The trunkings are resistant to aggressive and chemical environment (see pg. 5-4). The trunkings not resistant to UV rays and they are not suitable for the outside environment. Covering grade up to IP 40. Only for low voltage use. Trunkings and accessories for trunking distribution frame are usually supplied in a white colour RAL 9003. Selected trunkings are offered in light grey or in wood imitation. Other color shades are available on agreement. All trunkings (except for LV 11X10) have fixing holes at the bottom. The trunkings are delivered in lengths of 2 and 3 meters with ±10 mm tolerance at 20°C.
Insertion trunkings ..................................................................................................................................................................................................................................... 2-5 It is possible to install wiring trunkings in places with explosive risk of flammable liquids – dangers zone 2, explosibility dust – danger zone 22 in compliance with ČSN EN 60 079-10. Angular trunkings ....................................................................................................................................................................................................................................... 2-8 A letter D, mentioned in a title of the truking, means double lock on lid for better lid fixing and higher stiffness of trunking. It is possible to install wiring trunkings in places with explosive risk of flammable liquids – dangers zone 2, explosibility dust – danger zone 22 in compliance with ČSN EN 60 079-10.
W I R I N G
Halogen-free trunkings ............................................................................................................................................................................................................................ 2-14 The trunkings are made from special self-snuffing material with temperature resistance -15 °C to +60 °C and don’t contain halogens. Trunkings made from this material are designed for housing and industrial distributions in hospitals, schools, station halls, service centers, etc. Suitable for environments with increased need of persons and facilities protection. The trunkings are resistant to spread of flame and can be installed on/into flammability class A1 to F materials.
Snap-on trunkings .................................................................................................................................................................................................................................... 2-17
Floor trunkings ......................................................................................................................................................................................................................................... 2-18 The LP 80X25 and LPK 80X25 floor trunkings with accessories are designed for installation in the corner between the wall and the floor of the room. The LPK 80X25 trunking has a slot allowing to insert a carpet. Use the LP 35 trunking for the same purpose.
Round trunkings ....................................................................................................................................................................................................................................... 2-22 The LO (35; 50; 75) trunkings can be installed on the floor and weighted as usually in apartments and offices.
T R U N K I N G S
Elegant trunkings ..................................................................................................................................................................................................................................... 2-24 LE trunkings (40; 60; 80; 100) with device carriers are designed for wall installation. Do not install the trunkings on the floor, it is not designed for stress e.g. crushing. Wiring trunkings and elegant wiring trunkings ...................................................................................................................................................................................... 2-27 The EKD 80X40; EKD 100X40; EK 120X40 and EKE 60X60 type trunkings are designed for insertion of more cables or for cables with greater cross-sections. Instrument boxes can be inserted directly into the EKE trunking body (100X60; 140X60; 180X60) and common types of instruments can be then installed. The individual conductors can be electromagnetically screened out by inserting the shielding trunking and prevent thus spurious effects. In the case of installation of the SK 40X33 shielding trunking (higher), instruments with greater mounting depth or instruments with over-voltage protection cannot be used. The producer recommends check the depth of the instrument before installation. It is possible to install wiring trunkings in places with explosive risk of flammable liquids – dangers zone 2, explosibility dust – danger zone 22 in compliance with ČSN EN 60 079-10. Parapet trunkings ..................................................................................................................................................................................................................................... 2-32 Parapet trunkings are designed for bedding of power and message circuits, security lines and other distribution systems. They are installed to the level of window parapets or above the work tables. The instrument boxes can be inserted directly into the body of one-compartment trunkings (PK 110X70 D, PK 140X70 D a PK 170X70 D) and common types of instruments can be then installed. The PK 90X55 D one-compartment trunking and the bodies of two-compartment trunkings (PK 120X55 D a PK 160X65 D) are designed for installation of modular instruments 45 x 45 mm. The body of the PK 210X70 D two-compartment trunking has one compartment designed for installation of instrument boxes, to which common types of instruments may be subsequently installed, and second compartment for installation of modular instruments 45 x 45 mm. The individual conductors can be electromagnetically screened out by inserting the shielding trunking and prevent thus spurious effects. In the case of installation of the SK 40X33 shielding trunking (higher), instruments with greater mounting depth or instruments with over-voltage protection cannot be used. The producer recommends check the depth of the instrument before installation. The parapet trunkings are manufactured with double wall to provide higher rigidity of the trunking. Partition walls ........................................................................................................................................................................................................................................... 2-38
Shielding canals ....................................................................................................................................................................................................................................... 2-40
Instrument carriers and accessories ...................................................................................................................................................................................................... 2-41
Support rails ............................................................................................................................................................................................................................................. 2-46 Distributing trunkings .............................................................................................................................................................................................................................. 2-47 Distributing trunkings are side-fenestrated conduits for installation of distributors.
2
Wiring trunkings and accessories
2
Tr u n k i n g d i s t r i b u t i o n a c c e s s o r i e s p a c k a g e : Covers, instrument carriers, caps, spacers …............…… 10 pcs each Covers and instrument carriers in wood imitation (I1 and I2) may be delivered in singles partition walls:
PEK 40 JC ……….......……………. 2 / 40 m PEK 40 JA ………………….......….. 3 / 60 m PEKE 60 …………….......…………. 2 / 20 / 160 m
PKS 70/60 ...................................... 2 / 20 / 160 m PEP 60 ........................................... 2 m PEP 60/K ........................................ 2 m
spacers:
the spacers are a part of the package for trunkings LH, EK, EKE LH, EK, EKD, EKE - 2 m ............. 2 pcs. of spacers LH, EK - 3 m ................................ 3 pcs. of spacers
W I R I N G T R U N K I N G S
All trunkings and respective accessories are in compliance with EU directions. All trunkings and respective accessories (except for shading trunkings and support trunkings) are in compliance with German electrical standard.
Icons - capture material
spacing (mm)
temperature resistance, scope of application (°C)
products manufactured from leadless material
flaming loop test
halogen-free material
fire class
color
self-snuffing
outside dimensions - width, height (mm)
impact strength (J) very low = 0,5 J; low = 1 J; medium = 2 J
inside dimensions - width, height (mm)
inside area (mm2)
outside diameter (mm)
allows to install double-socket
package (m)
allows installing wall socket 380 V / 16 A (32 A)
available as additional assortment
3
2
W I R I N G T R U N K I N G S
4
Meaning of the used configuration length trunkings
package trunkings
white RAL 9003
3m
PE foil
-
-
white RAL 9003
2,6 m
PE foil
1 - 10 pcs
-
HD
white RAL 9003
2m
carton
-
-
I1
imitation - pink birch
2m
carton
1 - 10 pcs
-
I2
imitation - dark oak
2m
carton
1 - 10 pcs
-
KA
light grey RAL 7035
3m
PE foil
-
-
KB
light grey RAL 7035
-
-
1 - 10 pcs
-
KD
light grey RAL 7035
2m
carton
-
-
configuration
color
HA HB
quantity at each packing accessories
note
LB
dark grey RAL 7012
-
-
1 - 10 pcs
-
LD
dark grey RAL 7012
2m
carton
-
-
CD
blue RAL 5015
2m
carton
-
-
P1
white RAL 9003
3m
PE foil
-
trunking with self-adhesive tape
P2
white RAL 9003
2m
carton
-
trunking with self-adhesive tape
SD
light wood - light brown
2m
carton
-
-
TD
dark wood - dark brown
2m
carton
-
-
I2
I1
HD
SD
TD
2
Insertion trunking
trunking box (pg. 1-22 - 1-25)
end inner corner
grommet outer corner
bending
branching
instrument carrier connecting
spacer example LV 40X15
LV 11X10
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
45 mm2
The smallest dimension of trunkings produced in KOPOS KOLÍN a.s. Due to its dimensions, it is supplied without accessories.
item
conf.
L
description
m
HA HC LV 11X10
HD
package - foil white RAL 9003
package - carton
EAN m
3
180; 3600
8595057601291
2
120; 2400
8595057601635
2
150
8595057608504
P1
package - foil
3
150
8595057665880
P2
package - carton
2
150
8595057690936
material
temperature resistance
self-snuffing
inside area
fire class
flaming loop test
impact strength
color
W I R I N G T R U N K I N G S
package
5
2
LV 18X13
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
conf. HA
package - foil
HC
package - foil package - carton
P2
package - carton, self-adhesive tape package - carton
bending
8732
branching
8733
inner corner
8734
EAN
m
m
3
264; 3168
8595057601338
2
176
8595057601659
2
70
8595057608511
white
2
70
8595057690943
light wood
2
70
8595568903068
dark wood
2
70
8595568903075
outer corner
grommet
8736
8737, 8738, 8739
8735
raised grommet 8739 Z
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
I2
1
I2
1
I2
1
I2
1
I2
1
I2
1
I1
1
SD
1
SD
1
SD
1
SD
1
SD
1
SD
1
I2
1
SD
1
Using grommet covers: 8737 for LK 80X16 boxes ... 8739 for LK 80X20 boxes ...
T R U N K I N G S
white RAL 9003
HD
TD
connecting
L
description
SD
8731
TD
SD
Designed for wall or ceiling mounting.
LV 18X13
end
HD
145 mm2
Standard shape.
item
W I R I N G
0,5 J
8739 for LK 80X28 boxes ... 8739 Z for LK 80X28 boxes ... - when backing with thermal insulating pad PI
LV 24X22
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
conf.
8791
6
bending
8792
package - foil
HC
LV 24X22
L
description
HA
connecting
400 mm2
Standard shape.
item
end
0,5 J
white RAL 9003
HD
package - carton
P2
package - carton, self-adhesive tape
branching
8793
inner corner
8794
white
outer corner
8795
EAN
m
m
3
144; 1296
2
96; 864
8595057601673
2
40
8595057609532
2
30
8595057690950
grommet (LK 80X28...)
8796
8797
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
8595057601420
2
LV 40X15
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
540 mm2
0,5 J
Standard shape. Designed for wall or ceiling mounting. Also available are accessories for instrument installation.
item
conf. HA
EAN
m
m
package - foil
HC LV 40X15
L
description
white RAL 9003
3
105; 1260
8595057601468
2
70; 840
8595057601697
2
30
8595057609433
HD
package - carton
P1
package - foil, self-adhesive tape
3
75
8595057665910
P2
package - carton, self-adhesive tape
2
30
8595057690967
PN 40X15 pg. 2-42
end
connecting
bending
branching
inner corner
outer corner
grommet (LK 80X20...)
raised grommet (LK 80X28...)
8711
8714
8716
8715
8713/2
8712/2
8717
8719, 8719 Z
conf.
package
HB
10
conf. HB
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
Using grommet covers: 8717 for LK 80X16 boxes ... - when backing with thermal insulating pad PI 8719 for LK 80X28 boxes ... 8719 Z for LK 80X28 boxes ... - when backing with thermal insulating pad PI
spacer
W I R I N G
RLV 40X16 conf.
package
HB
500
T R U N K I N G S
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
7
2
Angular trunking instrument carrier
inner corner
branching
bending example LHD 40X20
outer corner
end
LH 15X10
W I R I N G
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
104 mm2
Standard shape. Designed for wall or ceiling mounting.
item
conf.
L
description
EAN
m
HA
T R U N K I N G S
LH 15X10
end
connecting
8681
8
bending
8682
package - foil
HC
white RAL 9003
HD
package - carton
P2
package - carton, self-adhesive tape
branching
8683
inner corner
8684
m
3
264; 3960
8595057616509
2
176; 2640
8595057616516
2
128
8595057621374
2
128
8595057690974
outer corner
8685
8686
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
2
LHD 17X17
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
190 mm2
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
m
HA
package - foil
HC LHD 17X17
white RAL 9003
EAN m
3
264; 2376
8595057616523
2
176; 1584
8595057616530
HD
package - carton
2
70
8595057619920
P1
package - foil
3
264; 2376
8595057665958
P2
package - carton, self-adhesive tape
2
70
8595057691001
end
connecting
bending
branching
inner corner
outer corner
8671
8672
8673
8674
8675
8676
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
W I R I N G T R U N K I N G S
LHD 20X10
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
140 mm2
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
EAN
m
HA LHD 20X10
end
connecting
8921
bending
8922
package - foil
HC
white RAL 9003
HD
package - carton
P2
package - carton, self-adhesive tape
branching
8923
inner corner
8924
m
3
90; 3240
8595057620575
2
60; 2160
8595057620568
2
96
8595057620582
2
96
8595057691018
outer corner
8925
8926
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
9
2
LHD 20X20
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
260 mm2
I2
conf.
LHD 20X20
L
description
package - foil white RAL 9003
HD
package - carton
P2
package - carton, self-adhesive tape
I1
pink birch
I2
package - carton
SD TD
T R U N K I N G S
connecting
bending
8622
branching
8623
inner corner
8624
EAN
m
m
3
147; 1964
8595057608870
2
98; 1176
8595057608894 8595057609617
2
48
2
48
8595057691025
2
24
8595057656659
dark oak
2
24
8595057656666
light wood
2
48
8595568903044
dark wood
2
48
8595568903051
outer corner
8625
grommet (LK 80X28...)
8626
transition branching (LP 80X25)
8629
8824/12
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
I1
1
I1
1
I1
1
I1
1
I1
1
I1
1
I1
1
-
-
I2
1
I2
1
I2
1
I2
1
I2
1
I2
1
I2
1
-
-
SD
1
SD
1
SD
1
SD
1
SD
1
SD
1
SD
1
-
-
LHD 25X15
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
300 mm2
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
EAN
m
HA
package - foil
HC LHD 25X15
end
connecting
8691
10
TD
Transition branching 8824/12 facilitates the transition to floor trunking LP 80X25 (pg. 2-18)
HA
8621
SD
Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
HC
end
HD
Designed for wall or ceiling mounting.
item
W I R I N G
I1
Standard shape.
bending
8692
white RAL 9003
m
3
60
8595057616547
2
40
8595057616554
HD
package - carton
2
50
8595057620599
P1
package - foil, self-adhesive tape
3
60
8595057665989
P2
package - carton, self-adhesive tape
2
50
8595057691032
branching
8693
inner corner
8694
outer corner
8695
8696
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
2
LHD 25X20
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
400 mm2
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
EAN
m
HA
package - foil
HC
LHD 25X20
white RAL 9003
HD
package - carton
P2
package - carton, self-adhesive tape
end
connecting
bending
branching
inner corner
outer corner
8911
8912
8913
8914
8915
8916
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
m
3
75; 150
8595057616820
2
50; 100
8595057616837
2
40
8595057616844
2
40
8595057691049
W I R I N G T R U N K I N G S
LHD 30X25
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
480 mm2
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
EAN
m
HA
package - foil
HC LHD 30X25
end
connecting
8931
bending
8932
white RAL 9003
m
3
75; 900
8595057633865
2
50; 600
8595057633858
HD
package - carton
2
48
8595057633872
P1
package - foil, self-adhesive tape
3
75
8595057666009
P2
package - carton, self-adhesive tape
2
48
8595057691056
branching
8933
inner corner
8934
outer corner
8935
8936
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
11
2
LHD 32X15
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
340 mm2
0,5 J
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
EAN
m
HA LHD 32X15
W I R I N G
end
connecting
8601
package - carton
P2
package - carton, self-adhesive tape
branching
8603
inner corner
8604
3
90
8595057616561
2
60
8595057616578
2
88
8595057620605
2
88
8595057691063
outer corner
8605
8606
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
LHD 40X20
T R U N K I N G S
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
HD
SD
TD
Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation. Also available are accessories for instrument installation (pg. 2-42)
conf.
LHD 40X20
L
description
HA
package - foil
HD
package - carton
P1
package - foil, self-adhesive tape
P2
package - carton, self-adhesive tape
white RAL 9003
3
105; 945
8595057610149
2
70; 630
8595057610163
2
24
8595057610170
3
105; 945
8595057668935
2
24
8595057666023 8595057656673
pink birch
2
12
dark oak
2
12
8595057656680
light wood
2
24
8595568903082
dark wood
2
24
8595568903099
bending
8632
m
I2
package - carton
TD
connecting
EAN
m
I1 SD
8631
I1
Designed for wall or ceiling mounting.
item
end
I2
560 mm2
0,5 J
Standard shape.
HC
12
white RAL 9003
HD
bending
8602
package - foil
HC
m
branching
8633
inner corner
8634
outer corner
8635
grommet (LK 80X28...)
8636
8639
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
I1
1
I1
1
I1
1
I1
1
I1
1
I1
1
I1
1
I2
1
I2
1
I2
1
I2
1
I2
1
I2
1
I2
1
SD
1
SD
1
SD
1
SD
1
SD
1
SD
1
SD
1
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
PN 40X20 HB PN 40X20 I1 PN 40X20 I2 PN 40X20 SD pg. 2-42
2
LHD 40X40
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
HD
1300 mm2
SD
TD
Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
L
description
EAN
m
HA
package - foil
3
45; 405
8595057651685
white RAL 9003
2
30; 270
8595057651678
2
20
8595057651692
package - carton
light wood
2
20
8595568903105
dark wood
2
20
8595568903112
HC LHD 40X40
HD SD
m
TD
end
connecting
bending
branching
inner corner
outer corner
8641
8642
8643
8644
8645
8646
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
I2
1
I2
1
I2
1
I2
1
I2
1
I2
1
SD
1
SD
1
SD
1
SD
1
SD
1
SD
1
W I R I N G
LH 60X40
PVC
-5 - +60°C
8651 package
HB
10
conf. HB
0,5 J
1870 mm2
Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
conf.
L
description
HC
package - foil
HD
package - carton
bending
8652
conf.
30 sec.
Designed for wall or ceiling mounting.
LH 60X40
connecting
A1 - F
Standard shape.
item
end
850°C
bending round
8653
white RAL 9003
branching
8653R
EAN
m
m
2
24; 192
8595057610446
2
16
8595057610491
branching round
8654
inner corner (variable)
8654R
PEKD 40 pg. 2-38
T R U N K I N G S
outer corner (variable)
8655
8656
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
10
HB
10
HB
10
HB
10
HB
10
HB
2
HB
2
spacer RLH 60X40 conf.
package
HB
100
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
13
2
Halogen-free trunking
LHD 20X10HF
HF
use: -20 - +80°C
850°C
A1 - F
30 sec.
0,5 J
140 mm2
storage, transport, installation: -15 - +60°C
It does not contain halogen elements, suitable for environments with high concentrations of people. Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
LHD 20X10HF
W I R I N G T R U N K I N G S
end
connecting
8921HF
HD
branching
8923HF
white RAL 9003
inner corner
8924HF
EAN
m
m
2
96
8595057697744
outer corner
8925HF
8926HF
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
LHD 20X20HF
HF
850°C
use: -20 - +80°C
A1 - F
30 sec.
0,5 J
260 mm2
storage, transport, installation: -15 - +60°C
It does not contain halogen elements, suitable for environments with high concentrations of people. Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
LHD 20X20HF
end
connecting
8621HF
14
package - carton
bending
8922HF
L
description
bending
8622HF
HD
package - carton
branching
8623HF
L
description
8624HF
white RAL 9003
inner corner 8625HF
outer corner 8626HF
EAN
m
m
2
48
8595057657175
grommet 8629HF
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
halogen-free material
fire class
flaming loop test
impact strength
leadless material
color
package
2
LHD 40X20HF
HF
use: -20 - +80°C
850°C
A1 - F
30 sec.
0,5 J
1300 mm2
storage, transport, installation: -15 - +60°C
It does not contain halogen elements, suitable for environments with high concentrations of people. Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
conf.
LHD 40X20HF
L
description
HA
package - foil
HD
package - carton
white RAL 9003
EAN
m
m
3
105
8595057656420
2
24
8595057656437
end
connecting
bending
branching
inner corner
outer corner
grommet
8631HF
8632HF
8633HF
8634HF
8635HF
8636HF
8639HF
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
W I R I N G T R U N K I N G S
LHD 40X40HF
HF
850°C
use: -20 - +80°C
A1 - F
30 sec.
0,5 J
1870 mm2
storage, transport, installation: -15 - +60°C
It does not contain halogen elements, suitable for environments with high concentrations of people. Standard shape. Designed for wall or ceiling mounting. Double lock on lid increasing the trunking’s rigidity and ensuring stronger cover fixation.
item
conf.
LHD 40X40HF
end
connecting
8641HF
8642HF
bending
HA
package - foil
HD
package - carton
branching
8643HF
L
description
8644HF
white RAL 9003
inner corner 8645HF
EAN
m
m
3
45; 405
8595057657182
2
20
8595057657199
outer corner 8646HF
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
halogen-free material
fire class
flaming loop test
impact strength
leadless material
color
package
15
2
EKD 80X40HF
HF
use: -20 - +80°C
850°C
A1 - F
30 sec.
0,5 J
2430 mm2
storage, transport, installation: -15 - +60°C
It does not contain halogen elements, suitable for environments with high concentrations of people. Designed for inserting multiple cables, or cables of larger diameters. Possibility to insert PEKD 40 partition walls.
item
conf.
EKD 80X40HF
W I R I N G T R U N K I N G S
end
connecting
8501HF
package - carton
branching
8503HF
white RAL 9003
inner corner
8504HF
EAN
m
m
2
10
outer corner
spacer
8506HF
REKO 80X40HF
8505HF
8595057691278
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
100
PK 110X70 D HF
HF
use: -20 - +80°C
850°C
A1 - F
30 sec.
0,5 J
5500 mm2
storage, transport, installation: -15 - +60°C
It does not contain halogen elements, suitable for environments with high concentrations of people. Designed for inserting power and communication circuits, security lines and other lines. Individual lines can be electromagnetically shielded shielding by inserting a shielding canal. It is suitable for mounting conventional instruments. With using KOPOBOX mini P, modular devices can be installed (pg. 1-75).
item
conf.
PK 110X70 D HF
end
connecting
8451HF
16
HD
bending
8502HF
L
description
bending
8452HF
HD
package - carton
branching
8453HF
L
description
8454HF
white RAL 9003
inner corner 8455HF
outer corner 8456HF
EAN
m
m
2
6; 120
grommet 8457HF
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
material
temperature resistance
self-snuffing
inside area
halogen-free material
fire class
flaming loop test
impact strength
leadless material
color
package
8595568910622
2
Snap-on trunking
trunking box (pg. 1-30 - 1-37) trunking box (pg. 1-30 - 1-37) grommet for LK 80X28 LZ 15X12 grommet for LK 80X28 transition branching for LP 80X25
LZK 15X12 transition branching for LP 80X25
LP 80X25
LZ 15X12
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
140 mm2
One side of the lid is a part of the trunking body, the second side of the lid can be simply snapped on, it is fitted with double lock increasing the trunking´s rigidity and ensuring stronger cover fixation. item
conf.
L
description
EAN
m
HA
package - foil
HC HD
LZ 15X12
white RAL 9003
package - carton
m
3
60; 336
8595057611153
2
40; 224
8595057611177
2
96
8595057612426
KA
package - foil
light grey
3
60
8595057612259
KD
package - carton
light grey
2
96
8595057656475
grommet (LK 80X28...)
transition branching (LP 80X25)
8819
8824/41
conf.
package
conf.
package
HB
10
HB
10
W I R I N G T R U N K I N G S
LZK 15X12
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
120 mm2
One side of the rounded lid is a part of the trunking body, the second side of the lid can be simply snapped on, it is fitted with double lock increasing the trunking´s rigidity and ensuring stronger cover fixation. item
conf.
L
description
m
HA LZK 15X12
HC HD
grommet (LK 80X28...)
package - foil package - carton
white RAL 9003
EAN m
3
60
8595057614482
2
40
8595057614499
2
96
8595057620551
transition branching (LP 80X25)
8809
8824/40
conf.
package
conf.
package
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
17
2
Floor trunking transition branching for LHD 20X20
end
instrument carrier for double-socke
inner corner
transition bending for LHD 40X20
transition branching for LO 35 instrument carrier
outer corner
LP 80X25
W I R I N G
PVC
-5 - +60°C
850°C
A1 - F
450; 520; 400 mm2
0,5 J
It is designed for installation in the corner between the floor and wall. Also available are accessories for instrument installation (pg. 2-43).
item
conf.
L
description
EAN
m
HA
T R U N K I N G S
LP 80X25
package - foil
HC HD
end
end
8821 L
connecting
8821 P
white RAL 9003
package - carton
inner corner
8822
outer corner
8825
m
3
30
8595057602793
2
20
8595057602830
2
16
8595057609471
PN 80X25 PN 80X25 2Z pg. 2-43
transition branching transition branching transition branching (LHD 20X20) (LZK 15X12) (LZ 15X12)
8826
8824/12
8824/40
8824/41
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
transition branching transition branching (LO 35) (LO 50) 8824/43
18
30 sec.
transition bending (LHD 40X20)
8824/44
transition bending (LHD 40X20)
8823/13 L
8823/13 P
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
material
temperature resistance
self-snuffing
inside area
leadless material
fire class
flaming loop test
impact strength
for mounting a double-socket
color
package
2
LPK 80X25
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
450; 520; 400 mm2
0,5 J
It is designed for installation in the corner between the floor and wall. Includes a slot allowing to insert a carpet. Also available are accessories for instrument installation (pg. 2-43).
item
conf.
L
description
EAN
m
HA LPK 80X25
package - foil
HC HD
end
package - carton
3
30
8595057610767
2
20
8595057610774
2
16
8595057616318
transition branching transition branching transition branching transition branching transition branching (LHD 20X20) (LZK 15X12) (LZ 15X12) (LO 35) (LO 50)
end
8821 L
white RAL 9003
m
8821 P
8824/12
8824/40
8824/41
8824/43
8824/44
PN 80X25 PN 80X25 2Z pg. 2-43
transition bending (LHD 40X20) 8823/13 L
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
HB
10
T R U N K I N G S
transition bending (LHD 40X20) 8823/13 P conf.
package
HB
10
W I R I N G
material
temperature resistance
self-snuffing
inside area
leadless material
fire class
flaming loop test
impact strength
for mounting a double-socket
color
package
19
2
Floor trunking
inner corner end right
instrument carrier
end left
outer corner
LP 35
W I R I N G
PVC
850°C
A1 - F
30 sec.
0,5 J
350 mm2
TD
I2
Also available are accessories for instrument installation (pg. 2-43)
conf. HA
L
description
3
30
8595057615939
20
8595057615946
2
20
pink birch
2
20
dark oak
2
20
SD
light wood
2
20
PNLP 35 2Z HB PNLP 35 2Z I1 8595057667877 PNLP 35 2Z I2 8595057667884 PNLP 35 2Z SD pg. 2-43 8595568903761
TD
dark wood
2
20
8595568903778
LP 35
I1 I2
inner corner
8861 P
EAN m
2
package - foil
white RAL 9003
HD
8861 L
I1
Suitable for use with floating floors.
HC
end right
HD
Edge with softened spray application for better adhesion to the surface.
m
end left
SD
It is designed for installation in the corner between the floor and wall.
item
T R U N K I N G S
20
-5 - +60°C
package - carton
8595057615977
outer corner
8865
8866
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
10
HB
10
HB
10
I1
1
I1
1
I1
1
I1
1
I2
1
I2
1
I2
1
I2
1
SD
1
SD
1
SD
1
SD
1
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
2
Corner trunking
inner corner (access from three sides)
outer corner
inner corner
LR 30
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
560 mm2
Designed for installation in the corner between the floor and wall of the room as well as between two walls, or wall and ceiling. Length adjusted to standard room height.
item
conf.
LR 30
HB
inner corner
L
description package - foil
inner corner (access from three sides)
8855
white RAL 9003
EAN
m
m
2,6
26
outer corner
8855/3
8856
conf.
package
conf.
package
conf.
package
HB
5
HB
5
HB
10
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
8595057615908
W I R I N G T R U N K I N G S
21
2
Round trunking LO 50
transition branching for LP 80X25
LP 80X25
bending
trunking box (pg. 1-30 - 1-37)
branching grommet
LO 35
W I R I N G
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
2J
65; 65 mm2
LD
item
conf.
L
description
HA
LO 35
EAN
branching
8824/43
3
30
8595057615694
2
20
8595057615717 8595057619937
package - carton
2
60
P2
package - carton, self-adhesive tape
2
60
8595568902818
KA
package - foil
3
30
8595057615700
package - carton
LD
transition branching (LP 80X25)
white RAL 9003
m
HD
KD
8833
22
package - foil
HC
bending
HD
Designed for load capacity common in apartments and offices.
m
T R U N K I N G S
KD
Designed for mounting on the floor.
light grey dark grey
2
60
8595057656499
2
60
8595057662193
grommet (LK 80X28...)
8834
8837
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
10
HB
2
HB
2
KB
2
-
-
KB
2
KB
2
LB
2
-
-
LB
2
LB
2
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
2
LO 50
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
2J
60; 180; 60 mm2
LD
KD
HD
Designed for mounting on the floor. Designed for load capacity common in apartments and offices.
item
conf.
L
description
EAN
m
HA
package - foil
HC LO 50
white RAL 9003
m
3
30
8595057615342
2
20
8595057615359 8595057619944
HD
package - carton
2
32
P2
package - carton, self-adhesive tape
2
32
8595057689190
KA
package - foil
3
30
8595057615809
KD
light grey
package - carton
LD
bending
transition branching
branching
grommet
8843
8824/44
8844
8847
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
10
HB
2
HB
2
KB
2
-
-
KB
2
KB
2
LB
2
-
-
LB
2
LB
2
dark grey
2
32
8595057621404
2
32
8595057662216
W I R I N G
LO 75
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
2J
LD
170; 360; 170 mm2
HD
Designed for mounting on the floor. Designed for load capacity common in apartments and offices.
item
conf.
L
description
EAN
m
LO 75
HA
package - foil
HD
package - carton
P2 KA KD LD
bending
KD
m
3
30
8595057656567
2
28
8595057656574
package - carton, self-adhesive tape
2
28
8595568902405
package - foil
3
30
8595057656581
package - carton
white RAL 9003
light grey dark grey
2
28
8595057656598
2
28
8595057662223
T R U N K I N G S
branching
8873
8874
conf.
package
conf.
package
HB
2
HB
2
KB
2
KB
2
LB
2
LB
2
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
23
2
Elegant trunking inner corner
branching instrument carrier for double-socke
spacer
end bending outer corner instrument carrier
connecting
LE 80
LE 40
W I R I N G
PVC
T R U N K I N G S
850°C
A1 - F
30 sec.
0,5 J
500 mm2
Elegant shape. Designed for wall mounting. Not to be mounted on the floor or to be loaded by being stepped on, etc. Possibility to insert instrument carrier. Also available are accessories for instrument installation (pg. 2-41)
item
conf.
L
description
EAN
m
HA LE 40
end
connecting
package - foil
HC HD
8751
24
-5 - +60°C
package - carton
bending
8752
white RAL 9003
branching
8753
inner corner
8754
m
3
45
8595057620810
2
30
8595057620803
2
24
8595057620827
outer corner
8755
PNE 40 2Z pg. 2-41
grommet
8756
8757
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
material
temperature resistance
self-snuffing
inside area
leadless material
fire class
flaming loop test
impact strength
for mounting a double-socket
color
package
2
LE 60
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
380; 380 mm2
Elegant shape. Designed for wall mounting. Not to be mounted on the floor or to be loaded by being stepped on, etc. Possibility to insert instrument carrier. Also available are accessories for instrument installation (pg. 2-41)
item
conf.
L
description
EAN
m
HA LE 60
package - foil
HC HD
white RAL 9003
package - carton
m
3
30
8595057620872
2
20
8595057620865
2
18
8595057620889
end
connecting
bending
branching
inner corner
outer corner
8761
8762
8763
8764
8765
8766
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
PNE 60X20 PNE 60X20 2Z pg. 2-41
W I R I N G T R U N K I N G S
LE 80
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
0,5 J
420; 420 mm2
Elegant shape. Designed for wall mounting. Not to be mounted on the floor or to be loaded by being stepped on, etc. Possibility to insert instrument carrier. Also available are accessories for instrument installation (pg. 2-41)
conf.
L
description
EAN
m
HA LE 80
HD
end
connecting
8771
package - foil
HC
package - carton
bending
8772
white RAL 9003
branching
8773
inner corner
8774
m
3
30
8595057620933
2
20
8595057620926
2
20
8595057620940
outer corner
8775
PNE 80X20 PNE 80X20 2Z pg. 2-41
spacer
8776
RLE 80
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
10
material
temperature resistance
self-snuffing
inside area
leadless material
fire class
flaming loop test
impact strength
for mounting a double-socket
color
package
25
2
LE 100
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
0,5 J
380; 340; 380 mm2
Elegant shape. Designed for wall mounting. Not to be mounted on the floor or to be loaded by being stepped on, etc. Possibility to insert instrument carrier.
item
conf.
L
description
EAN
m
HA LE 100
package - foil
HC HD
W I R I N G
end
connecting
8781
package - carton
bending
8782
white RAL 9003
branching
8783
inner corner
8784
m
3
30
8595057620995
2
20
8595057620988
2
16
8595057621008
outer corner
8785
PNE 100X20 pg. 2-41
spacer
8786
RLE 100
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
10
T R U N K I N G S Installation of the elegant LE trunking system.
26
material
temperature resistance
self-snuffing
inside area
leadless material
fire class
flaming loop test
impact strength
for mounting a double-socket
color
package
2
Wiring trunking elegant shielding canal
partition wall
clamp for shielding canal inner corner outer corner
end spacer bending
branching connecting
instrument box
instrument washer
EKE 140X60
EKE 60X60
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
It is designed for inserting multiple cables, or cables of larger diameters. Possibility to insert PEKE 60 and PKS 70/60 partition walls.
item
conf.
L
description
EAN
m
HA EKE 60X60
HC HD
end
connecting
8541
W I R I N G
2600 mm2
bending
8542
package - foil
white RAL 9003
package - carton
branching
8543
inner corner
8544
m
3
36
8595057620759
2
20
8595057620742
2
18; 270
8595057620766
outer corner
8545
8546
PEKE 60 PEKE 70/60 pg. 2-38; 2-39
T R U N K I N G S
spacer
REKE 60
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
9
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
27
2
EKE 100X60
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
4600 mm2
0,5 J
It is designed for inserting multiple cables, or cables of larger diameters. Possibility to insert partition wall or shielding canal. Possibility to insert an instrument box and subsequently mount common types of instruments.
item
conf.
L
description
HA
EAN
m
m
3
12
2
8; 160
2
8; 160
PEKE 60 PKS 70/60 PEP 60; PEP 60/K SK 40X20 8595057620728 SK 40X33 KP EKE 8550... 8595057620735 pg. 2-38 - 2-44 8595057620711
package - foil EKE 100X60
white RAL 9003
HC HD
W I R I N G T R U N K I N G S
end
connecting
8551
package - carton
bending
8552
branching
8553
inner corner
8554
outer corner
8555
spacer
8556
REKE 100
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
9
EKE 140X60
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
7000 mm2
0,5 J
It is designed for inserting multiple cables, or cables of larger diameters. Possibility to insert partition wall or shielding canal. Possibility to insert an instrument box and subsequently mount common types of instruments.
item
conf.
L
description
HA
EAN
m
m
3
9
2
6; 126
2
6; 126
PEKE 60 PKS 70/60 PEP 60; PEP 60/K SK 40X20 8595057620681 SK 40X33 KP EKE; PN EKE 8560... 8595057620704 pg. 2-38 - 2-44 8595057620698
package - foil EKE 140X60
white RAL 9003
HC HD
end
connecting
8561
28
package - carton
bending
8562
branching
8563
inner corner
8564
outer corner
8565
8566
spacer
REKE 140
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
9
material
temperature resistance
self-snuffing
inside area
for mounting a wall socket
color
fire class
flaming loop test
impact strength
for mounting a double-socket
leadless material
package
2
EKE 180X60
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
9000 mm2
0,5 J
It is designed for inserting multiple cables, or cables of larger diameters. Possibility to insert partition wall or shielding canal. Possibility to insert an instrument box and subsequently mount common types of instruments.
item
conf.
L
description
HA
EAN
m
m
3
9
2
6; 90
2
6; 90
PEKE 60 PKS 70/60 PEP 60; PEP 60/K SK 40X20 8595057620650 SK 40X33 KP EKE PN EKE 8595057620674 pg. 2-38 - 2-44 8595057620667
package - foil EKE 180X60
white RAL 9003
HC HD
package - carton
end
connecting
bending
branching
inner corner
outer corner
spacer
8571
8572
8573
8574
8575
8576
REKE 180
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
9
W I R I N G T R U N K I N G S
Installation of the elegant EKE trunking system.
material
temperature resistance
self-snuffing
inside area
for mounting a wall socket
color
fire class
flaming loop test
impact strength
for mounting a double-socket
leadless material
package
29
2
Wiring trunking EKD 80X40 spacer
inner corner (variable ±10°)
bending
branching
transition branching
partition wall
outer corner (variable ±15°)
end
EKD 80X40
W I R I N G
PVC
850°C
connecting
8501
30 sec.
0,5 J
2430 mm2
Possibility to insert PEKD 40 partition walls.
conf.
EKD 80X40
end
A1 - F
It is designed for inserting multiple cables, or cables of larger diameters.
item
T R U N K I N G S
30
-5 - +60°C
bending
8502
L
description
HA
package - foil
HD
package - carton
branching
8503
8504
white RAL 9003
transition branching
EAN
m
m
3
30; 240
8595057692671
2
10
8595057690455
inner corner
8504/EKD
PEKD 40 pg. 2-38
outer corner
8505
8506
spacer REKO 80X40
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
100
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
2
EKD 100X40
PVC
-5 - +60°C
850°C
A1 - F
30 sec.
0,5 J
3010 mm2
It is designed for inserting multiple cables, or cables of larger diameters. Possibility to insert PEKD 40 partition walls.
item
conf.
EKD 100X40
L
description
HA
package - foil
HD
package - carton
white RAL 9003
EAN
m
m
3
30
8595057693234
2
8
8595057690530
PEKD 40 pg. 2-38
end
connecting
bending
branching
transition branching
inner corner
outer corner
spacer
8511
8512
8513
8514
8514/EKD
8515
8516
REKO 100X40
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
100
T R U N K I N G S
EKD 120X40
PVC
-5 - +60°C
850°C
8581
0,5 J
4000 mm2
Possibility to insert PEKD 40 partition walls.
conf.
EKD 120X40
connecting
30 sec.
It is designed for inserting multiple cables, or cables of larger diameters.
item
end
A1 - F
bending
8582
L
description
HA
package - foil
HD
package - carton
branching
8583
8584
white RAL 9003
transition branching
EAN
m
m
3
30
8595057699311
2
8
8595057690615
inner corner
8584/EKD
PEKD 40 pg. 2-38
outer corner
8585
8586
W I R I N G
spacer REKO 120X40
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
100
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
31
2
H o l l o w pa r a p e t t r u n k i n g PK 140X70 D clamp for shielding canal inner corner
shielding canal
outer corner end
partition wall
branching
bending
connecting
instrument washer
grommet instrument box
Perimeter trunking PK ...X 70 D are designed for instalation of standard instruments. Instrumens are installing by click on bottom of trunking. According of amount of instruments side by side and dimmension of trunking is choose corresponding instrument washer. For shielding of data cables can be used shielding canal SK 40X..., which is fixed with clips PSK 1 to the canal bottom.
W I R I N G
PK 110X70 D
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
1J
5500 mm2
Designed for inserting power and communication circuits, security
lines and other lines.
Individual lines can be electromagnetically shielded by inserting a shielding canal.
T R U N K I N G S
For a classical instrument with a height of 80 mm.
item
conf.
L
description
HA
EAN
m
m
3
18
2
12
2
6; 120
PEKE 60 PKS 70/60 PEP 60; PEP 60/K SK 40X20 8595057632875 SK 40X33 KP PK 8450... 8595057632882 pg. 2-38 - 2-44 8595057632868
package - foil PK 110X70 D
white RAL 9003
HC HD
end
connecting
8451
bending
8452
package - carton
branching
8453
inner corner
8454
outer corner
8455
grommet
8456
8457
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
KOPOBOX mini P Multi-purpose instrument box for modular devices useful for mounting into perimeter trunking. More in pg. 1-75
32
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
2
PK 140X70 D
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
7200 mm2
1J
Designed for inserting power and communication circuits, security lines and other lines. Individual lines can be electromagnetically shielded by inserting a shielding canal. For a classical instrument.
item
conf.
L
description
HA
EAN
m
m
3
9
2
6
2
6, 108
PEKE 60 PKS 70/60 PEP 60; PEP 60/K SK 40X20 8595057632905 SK 40X33 KP PK; PN PK 8440... 8595057632912 pg. 2-38 - 2-44 8595057632899
package - foil PK 140X70 D
white RAL 9003
HC HD
package - carton
end
connecting
bending
branching
inner corner
outer corner
grommet
8461
8462
8463
8464
8465
8466
8467
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
W I R I N G T R U N K I N G S
PK 170X70 D
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
9300 mm2
1J
Designed for inserting power and communication circuits, security lines and other lines. Individual lines can be electromagnetically shielded by inserting a shielding canal. For a classical instrument.
item
conf.
L
description
HA
EAN
m
m
3
9
2
6
2
6, 84
PEKE 60 PKS 70/60 PEP 60; PEP 60/K SK 40X20 8595057632936 SK 40X33 KP PK; PN PK 8440... 8595057632943 pg. 2-38 - 2-44 8595057632929
package - foil PK 170X70 D
white RAL 9003
HC HD
end
connecting
8441
package - carton
bending
8442
branching
8443
inner corner
8444
outer corner
8445
grommet
8446
8447
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
material
temperature resistance
self-snuffing
inside area
for mounting a wall socket
color
fire class
flaming loop test
impact strength
for mounting a double-socket
leadless material
package
33
2
H o l l o w pa r a p e t t r u n k i n g
inner corner (variable ±8°)
end outer corner (variable ±8°) bending
branching connecting
grommet partition wall
PK 90X55 D
W I R I N G
PVC
850°C
A1 - F
30 sec.
1J
3800 mm2
Designed for installation of modular devices 45 x 45 or 45 x 22,5 mm. KOPOS recommends to install instruments from ABB, Legrand, PEHA, Schneider Electric and Simon connect.
To separate the circuit, partition wall PEKE 60 can be used. When having to shield data-type circuitry, use partition wall PKS 70/60, which provides similar properties as a metal rail with low weight and easy installation.
T R U N K I N G S
Maximum number of modular instruments placed next to each other is 3 pcs. When installing multiple instruments next to each, put about 5 cm wide piece of lid to fasten them.
No lids are necessary for the final installation of instrument. The lid is cut to the desired length and inserted next to the instrument.
item
conf.
PK 90X55 D
end
connecting
8401
34
-5 - +60°C
HD
bending
8402
L
description
white RAL 9003
package - carton
branching
8403
inner corner
8404
EAN
m
m
2
12
outer corner
8405
8595057688056
grommet
8406
8407
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
PEKE 60 PKS 70/60 pg. 2-39; 2-39
2
H o l l o w pa r a p e t t r u n k i n g inner corner (variable ±8°)
end outer corner (variable ±20°)
shielding canal
bending
connecting
branching
grommet
PK 120X55 D
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
1550/ 2250 mm2
1J
Designed for installation of modular devices 45 x 45 or 22,5 x 45 mm. KOPOS recommends to install instruments from ABB, Legrand, PEHA, Schneider Electric and Simon connect. The tilting section allows inserting the shielding canal SK 40X ..., which ensures perfect shielding of data circuits. Maximum number of modular instruments placed next to each other is 3 pcs. When installing multiple instruments next to each, put about 5 cm wide piece of lid to fasten them.
No lids are necessary for the final installation of instrument. The lid is cut to the desired length and inserted next to the instrument.
item
conf.
L
description
EAN
m
PK 120X55 D
end
connecting
8471
HD
bending
8472
white RAL 9003
package - carton
branching
8473
inner corner
8474
m
2
6
outer corner
8475
8595057650572
grommet
8476
PEKE 60 PKS 70/60 SK 40X20 SK 40X33 pg. 2-38 - 2-40
W I R I N G T R U N K I N G S
8477
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
35
2
H o l l o w pa r a p e t t r u n k i n g inner corner (variable ±8°)
end outer corner (variable ±20°)
bending
branching partition wall grommet
PK 160X65 D
W I R I N G
PVC
A1 - F
30 sec.
3800/ 3600 mm2
1J
Designed for installation of modular devices 45 x 45 or 22,5 x 45 mm. KOPOS recommends to install instruments from ABB, Legrand, PEHA, Schneider Electric and Simon connect.
The mechanical division or separation of circuit in terms of electromagnetic compatibility, you can use the partition walls PEKE 60 or PKS 70/60.
T R U N K I N G S
Maximum number of modular instruments placed next to each other is 3 pcs. When installing multiple instruments next to each, put about 5 cm wide piece of lid to fasten them.
No lids are necessary for the final installation of instrument. The lid is cut to the desired length and inserted next to the instrument.
item
conf.
PK 160X65 D
end
connecting
8481
36
850°C
-5 - +60°C
HD
bending
8482
L
description
white RAL 9003
package - carton
branching
8483
inner corner
8484
EAN
m
m
2
6
outer corner
8485
8595057657205
grommet
8486
8487
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
2
HB
2
HB
2
HB
2
HB
2
HB
2
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
PEKE 60 PKS 70/60 pg. 2-38; 2-39
2
H o l l o w pa r a p e t t r u n k i n g inner corner (variable ±8°)
end
outer corner (variable ±8°)
partition wall
bending
instrument washer
partition wall
branching
instrument box
grommet
PK 210X70 D
PVC
850°C
-5 - +60°C
A1 - F
30 sec.
4400/3100 mm2
1J
Designed for installation of modular and standard devices 45 x 45 or 45 x 22,5 mm. KOPOS recommends to install instruments from ABB, Legrand, PEHA, Schneider Electric and Simon connect. Its design allows inserting shielding canals SK 40X ..., all kinds of partition walls, including metal ones, which serve as a shield, providing a great fixation of cables in the desired position.
KP PK instrument box with 8450 instrument washers are designed for mounting standard instruments and allow the installation of combined frames.
Maximum number of modular instruments placed next to each other is 3 pcs. When installing multiple instruments next to each, put about 5 cm wide piece of lid to fasten them. No lids are necessary for the final installation of instrument. The lid is cut to the desired length and inserted next to the instrument. Due to the above characteristics and cover integrity, this parapet trunking ranks among the products with the highest utility value offered by KOPOS KOLÍN a.s. in the area of parapet trunkings. This parapet trunking was awarded the Golden Amper diploma.
item
conf.
L
description
EAN
m
PK 210X70 D
end
connecting
8491
HD
bending
8492
white RAL 9003
package - carton
branching
8493
inner corner
8494
m
2
6
outer corner
8495
PEKE 60 PKS 70/60 PEP 60, PEP 60 K SK 40X20 8595057668683 SK 40X33 KP PK 8450... pg. 2-38 - 2-44
W I R I N G T R U N K I N G S
grommet
8496
8497
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
conf.
package
HB
10
HB
2
HB
1
HB
2
HB
2
HB
1
HB
2
material
temperature resistance
self-snuffing
inside area
color
fire class
flaming loop test
impact strength
leadless material
package
37
2
PEKD 40HF
- partition wall
PVC
30 sec.
It is used to divide the interior of the EKD HF trunkings, thus allowing a better manipulation with the inserted cables and clarity.
item PEKD 40HF
PEKD 40
W I R I N G
L
conf. HD
white
EAN
m
m
2
20
8595057691551
- partition wall
PVC
30 sec.
It is used to divide the interior of the EKD trunkings, thus allowing a better manipulation with the inserted cables and clarity.
item PEKD 40
L
conf. HD
white
EAN
m
m
2
20
8595057690448
T R U N K I N G S PEKE 60
- partition wall
PVC
30 sec.
It is used to divide the interior of the EKE and PK trunkings, thus allowing a better manipulation with the inserted cables and clarity.
item PEKE 60
38
L
conf. HD
white
material
leadless material
color
self-snuffing
halogen-free material
package
EAN
m
m
2
20
8595057627079
PKS 70/60
PVC
30 sec.
A thin layer of metal foil imparts similar properties as a metal partition wall, but is considerably lighter. Individual partition walls should be connected using PLSK connecting wire.
item PKS 70/60
PEP 60
2
- partition wall
conf. XX
L
EAN
m
m
2
20
8595057664364
- partition wall
PVC
30 sec.
It is used to divide the interior of the EKE and PK trunkings, thus allowing a better manipulation with the inserted cables and clarity.
item PEP 60
PEP 60/K
L
conf. HD
white RAL 9003
EAN
m
m
2
32
8595057668768
W I R I N G T R U N K I N G S
- partition wall
ZN
It is used to divide the interior of the EKE and PK trunkings, thus allowing a better manipulation with the inserted cables and clarity.
Individual partition walls should be connected using PLSK connecting wire.
item PEP 60/K
material
leadless material
self-snuffing
color
conf. S
L
EAN
m
m
2
24
8595057668775
package
39
2
SK 40X..
- shielding canal
SK 40X20 - 770 mm2
ZN
SK 40X33 - 1200 mm2
They are used to separate individual types of lines in terms of electromagnetic compatibility. It is composed of two parts, both made of 0.55 mm hot-dip galvanized sheet.
Can be mounted in EKE and PK trunkings. When mounting SK 40X33 trunking, you cannot use instruments with a greater mounting depth.
item
PSK 1
W I R I N G
conf.
L
EAN
m
m
SK 40X20
S
2
12
8595057614840
SK 40X33
S
2
12
8595057630291
- clamp for shielding canal
PVC
-5 - +60°C
A - C3
It is used to attach shielding canals to EKE and PK trunkings. To install, simply snap into the opposite holes in the shielding canal sides. It can be used to attach wires together with a fixing tape with a width of no more than 8 mm.
item
conf.
EAN pcs
T R U N K I N G S
PSK 1
PLSK
HB
5; 320
8595057629035
- interconnecting cable of shield trunking
It serves for perfect bonding of individual metal pieces of SK 40X.. shielding canals. Conductor diameter is 1.5 mm2. Supplied including the screws.
item
conf.
EAN pcs
PLSK
40
material
temperature resistance
fire class
inside area
XX
10
package
8595057627345
PNE...
2
- instrument carrier for trunkings LE
PVC
-5 - +60°C
A - C2
30 sec.
It consists of two parts - the carrier and cover. After removing the members in the vertical axis, you can mount the double-socket. Suitable for the following instruments: Classic, Tango, Swing, Time, Element and others with a max. width of 89 mm.
item
conf.
description
EAN pcs
PNE 60X20
HB
PNE 60X20 2Z
HB
PNE 80X20
HB
PNE 80X20 2Z
HB
PNE 100X20
HB
for trunkings LE 60 for trunkings LE 80
white RAL 9003
for trunkings LE 100
10; 60
8595057627475
10; 50
8595057627482
10; 60
8595057624689
10; 60
8595057627024
10; 50
8595057624672
W I R I N G
PNE 40 2Z
- instrument carrier for trunkings LE
PVC
-5 - +60°C
A - C2
30 sec.
It consists of two parts - the carrier and cover. After removing the members in the vertical axis, you can mount the double-socket. Suitable for the following instruments: Classic, Tango, Swing, Time, Element and others with a max. width of 89 mm.
item
conf.
description
T R U N K I N G S
EAN pcs
PNE 40 2Z
HB
for trunkings LE 40
material
temperature resistance
for mounting a double-socket
fire class
self-snuffing
color
white RAL 9003
10; 80
8595057652347
package
41
2
KP EKE
- instrument box for trunkings EKE
PVC
-5 - +60°C
A - C2
30 sec.
71
Allows inserting a shielding canal SK 40X... After removing the members for instrument screws (in the vertical axis), you can mount the double-socket.
item
conf.
EAN pcs
KP EKE
KP PK
W I R I N G
HB
white RAL 9003
10; 70
8595057621732
- instrument box for trunkings PK
PVC
-5 - +60°C
A - C2
30 sec.
71
Allows inserting a shielding canal SK 40X... After removing the members for instrument screws (in the vertical axis), you can mount the double-socket.
item
conf.
EAN pcs
T R U N K I N G S
PN 40X...
KP PK
HB
KP PK/1
HB
white RAL 9003
10; 80
8595057629011
50
8595057655195
- instrument carrier for LV 40X15 and LHD 40X20
PVC
-5 - +60°C
A - C2
30 sec.
It consists of two parts - the carrier and cover. Suitable for the following instruments: Classic, Tango, Swing, Time and others with a max. width of 83 mm.
item
conf.
description
EAN pcs
PN 40X15
PN 40X20
white RAL 9003
10; 60
HB
HB
10; 60
8595057610583
I1
pink birch
1; 60
8595057657021
I2
for trunkings LV 40X15
for trunkings LHD 40X20
SD
42
8595057610569
dark oak
1; 60
8595057657038
light wood
1; 60
8595568910370
material
temperature resistance
spacing
color
fire class
self-snuffing
for mounting a double-socket
package
PN 80X25...
2
- instrument carrier for trunkings LP (LPK) 80X25
PVC
-5 - +60°C
A - C2
30 sec.
It consists of two parts - the carrier and cover. Suitable for the following instruments: Classic, Tango, Swing, Time and others with a max. width of 83 mm. PN 80X25 2Z - allows to install double-socket.
item
conf.
EAN pcs
PN 80X25
PNLP 35 2Z
PN 80X25
HB
PN 80X25 2Z
HB
white RAL 9003
10; 70
8595057611443
10; 60
8595057611399
PN 80X25 2Z
- instrument carrier for trunkings LP 35
PVC
-5 - +60°C
A - C2
30 sec.
It consists of two parts - the carrier and cover. Suitable for the following instruments: Classic, Tango, Swing, Time, Element and others with a max. width of 89 mm. Instrument carrier with I2 configuration is suitable for the trunking with TD configuration.
item
conf.
EAN pcs
PNLP 35 2Z
PN EKE; PN PK
W I R I N G
HB
white RAL 9003
10; 80
8595057655041
I1
pink birch
1; 40
8595057669239
I2
dark oak
1; 40
8595057669352
SD
light wood
1; 40
8595568910387
T R U N K I N G S
- instrument carrier for EKE or PK trunkings
ZN
Instrument carrier for mounting 400 V sockets. The pitch for socket mounting is 50 and 60 mm. ZnCr finish.
item
conf.
EAN pcs
PN EKE
S
1; 24
8595057658028
PN PK
S
1; 40
8595057662377
material
temperature resistance
for mounting a double-socket
fire class
self-snuffing
color
package
43
2
8420...; 8440...; 8450...
- instrument washer for PK trunkings
PVC
-5 - +60°C
A - C2
30 sec.
71
To cover the mounting space of PK parapet trunkings. The 8440-11 single washer allows mounting the double-socket after removing the two fixing eyes.
item
conf.
for trunkings
EAN pcs
8440-11
HB
8440-12
HB
8440-13
HB
8450-11
HB
8450-12
HB
8450-13
HB
PK 140X70 D PK 170X70 D white RAL 9003 PK 110X70 D PK 210X70 D
10; 500
8595057644052
10; 340
8595057644069
10; 210
8595057644076
10; 780
8595057646759
10; 460
8595057646766
10; 300
8595057646773
W I R I N G T R U N K I N G S
44
8550...; 8560...;
- instrument washer for EKE trunkings
PVC
-5 - +60°C
A - C2
30 sec.
71
To cover the mounting space of EKE trunkings. The 8560-11 single washer allows mounting the double-socket after removing the two fixing eyes.
item
conf.
for trunkings
EAN pcs
8550-11
HB
8550-12
HB
8550-13
HB
8560-11
HB
8560-12
HB
8560-13
HB
EKE 100X60 white RAL 9003 EKE 140X60
2; 52
8595057646667
2; 78
8595057646674
2; 22
8595057646681
2; 42
8595057646698
2; 56
8595057646704
2; 34
8595057646711
material
temperature resistance
spacing
color
fire class
self-snuffing
for mounting a double-socket
package
SP...
For mounting on the bottom insertion support trunkings. For use on self-adhesive trunking, a sufficiently smooth and grease-free surface is required for mounting.
item
VK 20
2
- self-adhesive tape
L
conf.
EAN
mm
m
pcs
SP 12X1/10
XX
12 x 1
10
1
8595057620155
SP 15X1/10
XX
15 x 1
10
1
8595057620162
- blanking pliers
Intended for cutting a hole into the side of the trunking for turnout. Width of cut is c. 20 mm.
item
conf.
EAN pcs
VK 20
XX
1
8595057610125
W I R I N G T R U N K I N G S
L-42W
- trunking and pipes scissors
Intended for cutting trunkings into size 40 x 20 mm and pipes into 40 mm diameter.
item
conf.
EAN pcs
L-42W
XX
1
8595057611962
dimensions - height, width package
45
2
5822 DER
- plastic support rail
PVC
-5 - +60°C
In the central axis of the trunking, holes of 4.3 x 15 mm are cut to fasten the surface material.
5822 DER
W I R I N G
30 sec.
Designed for mounting standard clips (pg. 4-6) when mounting cables next to each other in a row.
item
5820/..
A - C2
L
conf. HA
EAN
mm
m
m
20 x 10
3
90
8595057605640
- metal support rail
steel
Designed for mounting standard clips (pg. 4-6) when mounting cables next to each other in a row.
item
L
conf. mm
T R U N K I N G S TS
perforated
EAN m
5820/20
S
3
non perforated
5820/21
S
3
perforated
5820/30
XX
3
non perforated
5820/31
XX
3
perforated
5820/40
F
3
non perforated
5820/41
F
3
perforated
20 x 10
material
m
Pre Galvanized without any surface hot dip galvanized
75
8595057605657
75
8595057605664
75
8595057605671
75
8595057605688
75
8595568903808
75
8595568903815
- metal support rail
steel
Designed for attaching instruments (circuit breakers, contactors, terminals, etc.) in distributors and instrument boards. At both ends there are holes and grooves for attaching to the washer.
item
conf.
description
L
finish mm
TS35 TS35 ZN TS35 ZN-CR TS35 P TS35 ZNP TS35 D TS35 D ZN TS35 D ZN-CR TS35 DP TS35 DZNP
46
XX S
with a break-off
ZNCR
XX
bare
-
35 x 7,5 3
Pre Galvanized
XX
bare
S
Pre Galvanized
ZNCR
according to specification
Pre Galvanized
ZNCR S
m
bare
with perforation
ZNCR
XX
bare
S
Pre Galvanized
material
temperature resistance
dimensions - height, width
fire class
self-snuffing
package
Sample: according to specification 35 x 7,5 3
TS 35 D ZNCR 0.2: perforated rail, ZNCR surface, length 0,2 m
RK ..X..
2
- distribution trunking
PVC
-20 - +60°C
A - C3
30 sec.
Optimal closing, fixed cover. Easy installation and removal. Trunkings are supplied with cover. Rib can be easily breaked out at the bottom of the trunking. For construction height 60 mm and above there are shaped ribs. Rib width 5,5 mm, cut-out width 4,5 mm.
L item DIN perforation in one row up to the width of 60 mm.
DIN perforation in two rows above the width of 80 mm.
RK ..X.. SF
conf.
mm wxh
mm wxh
m
m
EAN
number of conductors when 50% of the trunking capacity is filled 0,75 mm2 1 mm2 1,5 mm2 ∅2,8 mm ∅2,9 mm ∅3,2 mm
RK 25X30
LD
25 x 30
22 x 27
2
60
8595568902375
34
32
27
RK 30X30
LD
30 x 30
27 x 27
2
64
8595057623132
44
41
34
RK 25X40
LD
25 x 40
22 x 37
2
48
8595568902382
53
50
41
RK 30X40
LD
30 x 40
37 x 37
2
60
8595057623149
64
60
49
RK 40X40
LD
40 x 40
37 x 37
2
48
8595057623156
105
98
80
RK 60X40
LD
60 x 40
56 x 37
2
36
8595057623163
164
152
125
RK 30X60
LD
30 x 60
26 x 56
2
32
8595057623170
95
92
73
RK 40X60
LD
40 x 60
36 x 56
2
32
8595057623187
162
151
124
RK 60X60
LD
60 x 60
56 x 56
2
32
8595057623194
333
310
255
RK 80X60
LD
80 x 60
76 x 56
2
24
8595057623200
245
229
188
RK 100X60
LD
100 x 60
96 x 56
2
16
8595057623217
417
389
319
RK 120X60
LD
120 x 60
115 x 56
2
16
8595057623224
505
470
387
RK 30X80
LD
30 x 80
27 x 76
2
36
8595057623231
131
122
100
RK 40X80
LD
40 x 80
36 x 76
2
28
8595057623248
231
216
177
RK 60X80
LD
60 x 80
56 x 76
2
20
8595057623255
350
326
268
RK 80X80
LD
80 x 80
76 x 76
2
20
8595057623262
475
443
364
RK 100X80
LD
100 x 80
96 x 76
2
16
8595057623279
595
554
455
RK 120X80
LD
120 x 80
115 x 76
2
16
8595057623286
720
670
551
RK 25X100
LD
25 x 100
21 x 96
2
48
8595568902399
160
150
123
RK 30X100
LD
30 x 100
26 x 96
2
48
8595057623293
160
150
123
RK 40X100
LD
40 x 100
36 x 96
2
24
8595057623309
213
200
164
RK 60X100
LD
60 x 100
56 x 96
2
24
8595057623316
432
403
331
RK 80X100
LD
80 x 100
76 x 96
2
20
8595057623323
585
547
450
RK 100X100
LD
100 x 100
96 x 96
2
8
8595057623330
734
684
562
grey
- distribution trunking Safety
PVC
-20 - +60°C
A - C3
30 sec.
W I R I N G T R U N K I N G S
Conductor trunkings Safety are designed to use in extreme conditions. Optimal closing, fixed cover. Easy installation and removal. Trunkings are supplied with cover. Rib can be easily breaked out at the bottom of the trunking. For construction height 60 mm and above there are shaped ribs. Rib width 6 mm, cut-out width 4 mm.
L item
DIN perforation in one row up to the width of 60 mm.
DIN perforation in two rows above the width of 80 mm.
conf.
mm wxh
mm wxh
m
m
EAN
number of conductors when 50% of the trunking capacity is filled 0,75 mm2 1 mm2 1,5 mm2 ∅2,8 mm ∅2,9 mm ∅3,2 mm
RK 40X60 SF
CD
40 x 60
38 x 56
2
48
8595057623408
162
151
124
RK 60X60 SF
CD
60 x 60
56 x 56
2
36
8595057623415
245
229
188
RK 80X60 SF
CD
80 x 60
76 x 56
2
32
8595057623422
333
310
255
RK 30X80 SF
CD
30 x 80
27 x 76
2
48
8595057623446
169
157
129
RK 40X80 SF
CD
40 x 80
38 x 76
2
40
8595057623453
231
216
177
RK 60X80 SF
CD
60 x 80
56 x 76
2
36
8595057623460
350
326
268
RK 80X80 SF
CD
80 x 80
76 x 76
2
24
8595057623477
475
443
364
RK 100X80 SF
CD
100 x 80
96 x 76
2
24
8595057690851
595
554
455
RK 60X100 SF
CD
60 x 100
56 x 96
2
32
8595057623484
432
403
331
RK 100X100 SF
CD
100 x 100
96 x 96
2
16
8595057623491
734
684
562
blue
material
temperature resistance
color
inside dimensions - width, height
fire class
self-snuffing
dimensions - height, width
package
47
2
RK ..X.. DIN
- distribution trunking DIN
PVC
-20 - +60°C
A - C3
30 sec.
Optimal closing, fixed cover. Easy installation and removal. Trunkings are supplied with cover. Rib can be easily breaked out at the bottom of the trunking. For construction height 60 mm and above there are shaped ribs. Rib width 6 mm, cut-out width 4 mm.
L item DIN perforation in one row up to the width of 50 mm.
DIN perforation in two rows above the width of 75 mm.
W I R I N G T R U N K I N G S
conf.
mm wxh
mm wxh
m
m
EAN
0,75 mm2 1 mm2 1,5 mm2 ∅2,8 mm ∅2,9 mm ∅3,2 mm
RK 25X25 DIN
LD
25 x 25
20 x 20
2
48
8595057623606
32
30
25
RK 25X37.5 DIN
LD
25 x 37,5
20 x 33
2
54
8595057623613
55
50
41
RK 37.5X37.5 DIN
LD
37,5 x 37,5
33 x 33
2
40
8595057623620
80
75
61
RK 50X37.5 DIN
LD
50 x 37,5
45 x 33
2
32
8595057623637
121
112
92
RK 25X50 DIN
LD
25 x 50
20 x 45
2
64
8595057623644
73
68
56
RK 37.5X50 DIN
LD
37,5 x 50
33 x 45
2
32
8595057623651
121
112
92
RK 50X50 DIN
LD
50 x 50
45 x 45
2
42
8595057623668
165
153
126
RK 75X50 DIN
LD
75 x 50
70 x 45
2
28
8595057623675
256
239
196
RK 100X50 DIN
LD
100 x 50
95 x 45
2
20
8595057623682
347
324
266
RK 25X75 DIN
LD
25 x 75
20 x 70
2
36
8595057623705
114
109
87
RK 37.5X75 DIN
LD
37,5 x 75
33 x 70
2
24
8595057623712
188
175
144
RK 50X75 DIN
LD
50 x 75
45 x 70
2
28
8595057623729
256
239
196
RK 75X75 DIN
LD
75 x 75
70 x 70
2
24
8595057623736
398
371
305
RK 100X75 DIN
LD
100 x 75
95 x 70
2
16
8595057623743
540
504
414
RK 125X75 DIN
LD
125 x 75
118 x 70
2
16
8595057623750
671
625
514
RK ..X.. HF
grey
- halogen-free distribution trunking - DIN
PVC
-20 - +90°C
A - C3
30 sec.
Optimal closing, fixed cover. Easy installation and removal. Trunkings are supplied with cover. Rib can be easily breaked out at the bottom of the trunking. For construction height 60 mm and above there are shaped ribs. Rib width 6 mm, cut-out width 4 mm.
L
DIN perforation in one row up to the width of 50 mm.
DIN perforation in two rows above the width of 75 mm.
48
number of conductors when 50% of the trunking capacity is filled
item
conf.
RK 37.5X37.5 HF
LD
RK 37.5X50 HF
LD
RK 50X50 HF
LD
RK 75X50 HF
LD
RK 100X50 HF
LD
RK 37.5X75 HF
LD
RK 50X75 HF
mm wxh
EAN
number of conductors when 50% of the trunking capacity is filled 0,75 mm2 1 mm2 1,5 mm2 ∅2,8 mm ∅2,9 mm ∅3,2 mm
mm wxh
m
m
37,5 x 37,5
33 x 33
2
40
8595057623507
80
75
61
37,5 x 50
33 x 45
2
32
8595057623514
121
112
92
50 x 50
45 x 45
2
42
8595057623521
165
153
126
75 x 50
70 x 45
2
28
8595057623538
256
239
196
100 x 50
95 x 45
2
20
8595057623545
347
324
266
37,5 x 75
33 x 70
2
24
8595057623552
188
175
144
LD
50 x 75
45 x 70
2
28
8595057623569
256
239
196
RK 75X75 HF
LD
75 x 75
70 x 70
2
24
8595057623576
398
371
305
RK 100X75 HF
LD
100 x 75
95 x 70
2
16
8595057623583
540
504
414
RK 125X75 HF
LD
125 x 75
118 x 70
2
16
8595057623590
671
625
514
grey
material
temperature resistance
halogen-free material
dimensions - height, width
fire class
self-snuffing
color
inside dimensions - width, height
package
2
Accessories to distribution trunkings EAN mm
mm
mm
pcs
m
RK-OVK20
500
20
60
8595057623811
RK-OVK30
500
30
36
8595057623828
RK-OVK40
500
40
24
8595057623835
RK-OVK20
flexible conductor trunking (installation by means of bonding tape)
RK-ST6
spiral tube
fixing rivers
RK-ST6
6
30
8595057623842
RK-ST12
12
30
8595057623859
RK-ST22
22
30
8595057623866
RK-PN3,5
3,5
4000
8595057623903
RK-PN5
5
4000
8595057623910
RK-PN6
6
4000
8595057623927
W I R I N G T R U N K I N G S
dimensions - width
outside diameter
length
package
49
2
W I R I N G T R U N K I N G S
50
Covers for wiring trunkings and canals Type code 8401 8402 8403 8404 8405 8406 8407 8441 8442 8443 8444 8445 8446 8447 8451 8451HF 8452 8452HF 8453 8453HF 8454 8454HF 8455 8455HF 8456 8456HF 8457 8457HF 8461 8462 8463 8464 8465 8466 8467 8471 8472 8473 8474 8475 8476 8477 8481 8482 8483 8484 8485 8486 8487 8491 8492 8493 8494 8495 8496 8497 8501 8501HF 8502 8502HF 8503 8503HF 8504 8504HF 8504/EKD 8505 8505HF 8506 8506HF 8511 8512 8513 8514 8514/EKD 8515
HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB
EAN
pg.
Type code
8595057688063 8595057688070 8595057688087 8595057688094 8595057688100 8595057688117 8595057688124 8595057628953 8595057628960 8595057628977 8595057628984 8595057628991 8595057629004 8595057655188 8595057646780 8595568919373 8595057646797 8595568919380 8595057646803 8595568919397 8595057646810 8595568919403 8595057646827 8595568919410 8595057646834 8595568919427 8595057650640 8595568919434 8595057635135 8595057635142 8595057635159 8595057635166 8595057635173 8595057635180 8595057655171 8595057650589 8595057650596 8595057650602 8595057650619 8595057650626 8595057650633 8595057657052 8595057657069 8595057657076 8595057657083 8595057657090 8595057657106 8595057657113 8595057657120 8595057668690 8595057668706 8595057668713 8595057668720 8595057668737 8595057668744 8595057668751 8595057690462 8595057691285 8595057690479 8595057691292 8595057690486 8595057691308 8595057690493 8595057691315 8595057690523 8595057690509 8595057691322 8595057690516 8595057691339 8595057690547 8595057690554 9056185950576 8595057690578 8595057690608 8595057690585
2-34 2-34 2-34 2-34 2-34 2-34 2-34 2-33 2-33 2-33 2-33 2-33 2-33 2-33 2-32 2-16 2-32 2-16 2-32 2-16 2-32 2-16 2-32 2-16 2-32 2-16 2-32 2-16 2-33 2-33 2-33 2-33 2-33 2-33 2-33 2-35 2-35 2-35 2-35 2-35 2-35 2-35 2-36 2-36 2-36 2-36 2-36 2-36 2-36 2-37 2-37 2-37 2-37 2-37 2-37 2-37 2-30 2-16 2-30 2-16 2-30 2-16 2-30 2-16 2-30 2-30 2-16 2-30 2-16 2-31 2-31 2-31 2-31 2-31 2-31
8516 8541 8542 8543 8544 8545 8546 8551 8552 8553 8554 8555 8556 8561 8562 8563 8564 8565 8566 8571 8572 8573 8574 8575 8576 8581 8582 8583 8584 8584/EKD 8585 8586 8601 8602 8603 8604 8605 8606 8621 8621 8621 8621HF 8622 8622 8622 8622HF 8623 8623 8623 8623HF 8624 8624 8624 8624HF 8625 8625 8625 8625HF 8626 8626 8626 8626HF 8629 8629 8629 8629 8629HF 8631 8631 8631 8631 8631HF 8632 8632 8632
HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB I1 I2 HB HB HB I1 I2 HB HB I1 I2 HB HB I1 I2 HB I1 I2 HB HB HB I1 I2 HB HB I1 I2 SD HB I1 HB I2 SD HB I1 I2 HB
EAN
pg.
8595057690592 8595057622005 8595057622012 8595057622029 8595057622036 8595057622043 8595057622050 8595057622418 8595057622425 8595057622432 8595057622449 8595057622456 8595057622463 8595057622470 8595057622487 8595057622494 8595057622500 8595057622517 8595057622524 8595057622357 8595057622364 8595057622371 8595057622388 8595057622395 8595057622401 8595057690622 8595057690639 8595057690646 8595057690653 8595057690684 8595057690660 8595057690677 8595057620032 8595057620049 8595057620056 8595057620063 8595057620070 8595057620087 8595057656734 8595057656741 8595057609754 8595057655676 8595057609778 8595057656758 8595057656765 8595057655683 8595057610941 8595057656772 8595057656789 8595057655690 8595057610552 8595057656796 8595057656802 8595057655706 8595057656826 8595057656833 8595057611825 8595057655713 8595057611214 8595057656840 8595057656857 8595057655720 8595057608535 8595568909060 8595568909091 8595568909121 8595057655737 8595057656888 8595057610934 8595057656895 8595568905918 8595057655744 8595057656901 8595057656918 8595057609082
2-31 2-27 2-27 2-27 2-27 2-27 2-27 2-28 2-28 2-28 2-28 2-28 2-28 2-28 2-28 2-28 2-28 2-28 2-28 2-29 2-29 2-29 2-29 2-29 2-29 2-31 2-31 2-31 2-31 2-31 2-31 2-31 2-12 2-12 2-12 2-12 2-12 2-12 2-10 2-10 2-10 2-14 2-10 2-10 2-10 2-14 2-10 2-10 2-10 2-14 2-10 2-10 2-10 2-14 2-10 2-10 2-10 2-14 2-10 2-10 2-10 2-14 2-10 2-10 2-10 2-10 2-14 2-12 2-12 2-12 2-12 2-15 2-12 2-12 2-12
Type code 8632 8632HF 8633 8633 8633 8633 8633HF 8634 8634 8634 8634 8634HF 8635 8635 8635 8635 8635HF 8636 8636 8636 8636 8636HF 8639 8639 8639 8639 8639HF 8641 8641 8641 8641HF 8642 8642 8642 8642HF 8643 8643 8643 8643HF 8644 8644 8644 8644HF 8645 8645 8645 8645HF 8646 8646 8646 8646HF 8651 8652 8653 8653R 8654 8654R 8655 8656 8671 8672 8673 8674 8675 8676 8681 8682 8683 8684 8685 8686 8691 8692 8693 8694
SD HB I1 I2 HB SD HB HB I1 I2 SD HB HB I1 I2 SD HB HB I1 I2 SD HB HB I1 I2 SD HB HB I2 SD HB HB I2 SD HB HB I2 SD HB HB I2 SD HB HB I2 SD HB HB I2 SD HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB
EAN
pg.
8595568909909 8595057655751 8595057656925 8595057656932 8595057609020 8595568905833 8595057655614 8595057608658 8595057656949 8595057656956 8595568905444 8595057655768 8595057609105 8595057656963 8595057656970 8595568909961 8595057655775 8595057610811 8595057656987 8595057656994 8595568909183 8595057655782 8595057608672 8595568909084 8595568909114 8595568909145 8595057656642 8595057611023 8595568905482 8595568905475 8595057655799 8595057611931 8595568905536 8595568905529 8595057655812 8595057611986 8595568905826 8595568905819 8595057655812 8595057612020 8595568909893 8595568909886 8595057655829 8595057613157 8595568909978 8595568909985 8595057655836 8595057614055 8595568910042 8595568910035 8595057655843 8595057614109 8595057613256 8595057614284 8595057698598 8595057613270 8595057698604 8595057614260 8595057614246 8595057616752 8595057616745 8595057616738 8595057616714 8595057616721 8595057616707 8595057616813 8595057616806 8595057616790 8595057616783 8595057616776 8595057616769 8595057616622 8595057616615 8595057616608 8595057616592
2-12 2-15 2-12 2-12 2-12 2-12 2-15 2-12 2-12 2-12 2-12 2-15 2-12 2-12 2-12 2-12 2-15 2-12 2-12 2-12 2-12 2-15 2-12 2-12 2-12 2-12 2-15 2-13 2-13 2-13 2-15 2-13 2-13 2-13 2-15 2-13 2-13 2-13 2-15 2-13 2-13 2-13 2-15 2-13 2-13 2-13 2-15 2-13 2-13 2-13 2-15 2-13 2-13 2-13 2-13 2-13 2-13 2-13 2-13 2-9 2-9 2-9 2-9 2-9 2-9 2-8 2-8 2-8 2-8 2-8 2-8 2-10 2-10 2-10 2-10
Covers for wiring trunkings and canals Type code 8695 8696 8711 8712/2 8713/2 8714 8715 8716 8717 8719 8719Z 8731 8732 8733 8734 8735 8736 8737 8738 8739 8739 8739 8739 8739Z 8751 8752 8753 8754 8755 8756 8757 8761 8762 8763 8764 8765 8766 8771 8772 8773 8774 8775 8776 8781 8782 8783 8784 8785 8786 8791 8792 8793 8794 8795 8796 8797 8809 8819 8821 L 8821 P 8822 8823/13 L 8823/13 P 8824/12 8824/40 8824/41 8824/43 8824/44 8825 8826 8833 8833 8833 8834 8834
HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB I1 I2 SD HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB KB LB HB KB
EAN
pg.
8595057616585 8595057616691 8595057608696 8595057610613 8595057610354 8595057611849 8595057610040 8595057611559 8595057610620 8595057608719 8595057614420 8595057609303 8595057610330 8595057610392 8595057609327 8595057610651 8595057609341 8595057612143 8595057615311 8595057611252 8595568909077 8595568909107 8595568909138 8595057614406 8595057622166 8595057622173 8595057622180 8595057622197 8595057622203 8595057622210 8595057622227 8595057622296 8595057622302 8595057622319 8595057622326 8595057622333 8595057622340 8595057621923 8595057621930 8595057621947 8595057621961 8595057621954 8595057621978 8595057622234 8595057622241 8595057622258 8595057622265 8595057622272 8595057622289 8595057651609 8595057651616 8595057651623 8595057651630 8595057651647 8595057651654 8595057651661 8595057612686 8595057612679 8595057611337 8595057611313 8595057611108 8595057611467 8595057611481 8595057611191 8595057612709 8595057612693 8595057634008 8595057634015 8595057611719 8595057611283 8595057655218 8595057656505 8595057662230 8595057655225 8595057656512
2-10 2-10 2-7 2-7 2-7 2-7 2-7 2-7 2-7 2-7 2-7 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-24 2-24 2-24 2-24 2-24 2-24 2-24 2-25 2-25 2-25 2-25 2-25 2-25 2-25 2-25 2-25 2-25 2-25 2-25 2-26 2-26 2-26 2-26 2-26 2-26 2-6 2-6 2-6 2-6 2-6 2-6 2-6 2-17 2-17 2-18 2-18 2-18 2-18 2-18 2-18 2-18 2-18 2-18 2-18 2-18 2-18 2-22 2-22 2-22 2-22 2-22
Type code 8834 8837 8837 8837 8843 8843 8843 8844 8844 8844 8847 8847 8847 8855 8855/3 8856 8861 L 8861 L 8861 L 8861 L 8861 P 8861 P 8861 P 8861 P 8865 8865 8865 8865 8866 8866 8866 8866 8873 8873 8873 8874 8874 8874 8911 8912 8913 8914 8915 8916 8921 8921HF 8922 8922HF 8923 8923HF 8924 8924HF 8925 8925HF 8926 8926HF 8931 8932 8933 8934 8935 8936 REKE 100 REKE 140 REKE 180 REKE 60 REKO 80X40 REKO 80X40HF REKO 100X40 REKO 120X40 RLE 100 RLE 80 RLH 60X40 RLV 40X16
LB HB KB LB HB KB LB HB KB LB HB KB LB HB HB HB HB I1 I2 SD HB I1 I2 SD HB I1 I2 SD HB I1 I2 SD HB KB LB HB KB LB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB HB
EAN
pg.
8595057662247 8595057617131 8595057656543 8595057662254 8595057654969 8595057656529 8595057662261 8595057654976 8595057656536 8595057662278 8595057615793 8595057656550 8595057662285 8595057634039 8595057634022 8595057634046 8595057634053 8595057669291 8595057669314 8595568905543 8595057638792 8595057669246 8595057669321 8595568905550 8595057634060 8595057669253 8595057669338 8595568905567 8595057634077 8595057669307 8595057669345 8595568905512 8595057656604 8595057656611 8595057662292 8595057656628 8595057656635 8595057662308 8595057616684 8595057616677 8595057616660 8595057616639 8595057616646 8595057616653 8595057619975 8595057698536 8595057619982 8595057698543 8595057619999 8595057698550 8595057620001 8595057698567 8595057620018 8595057698574 8595057620025 8595057698581 8595057633889 8595057633896 8595057633902 8595057633919 8595057633926 8595057633933 8595057626409 8595057626393 8595057626386 8595057626416 8575057690691 8595057692060 8575057690707 8595057690714 8595057624696 8595057624702 8595057610385 8595057603202
2-22 2-22 2-22 2-22 2-23 2-23 2-23 2-23 2-23 2-23 2-23 2-23 2-23 2-21 2-21 2-21 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-20 2-23 2-23 2-23 2-23 2-23 2-23 2-11 2-11 2-11 2-11 2-11 2-11 2-9 2-14 2-9 2-14 2-9 2-14 2-9 2-14 2-9 2-14 2-9 2-14 2-11 2-11 2-11 2-11 2-11 2-11 2-28 2-28 2-29 2-27 2-30 2-16 2-31 2-31 2-26 2-25 2-13 2-7
2
W I R I N G T R U N K I N G S
51
2
Wiring trunkings - number of inserted cables cables construction
2 x 1,5
3 x 1,5
4 x 1,5
3 x 2,5
5 x 1,5
4 x 2,5
5 x 2,5
4x4
5x4
4x6
5x6
6
8,3
8,7
9,5
10
10,3
10,9
12,3
13,2
14,4
14,4
16
LV 11X10
1
X
X
X
X
X
X
X
X
X
X
X
LV 18X13
2
1
1
1
1
1
1
X
X
X
X
X
LV 24X22
7
3
3
3
2
2
2
2
1
1
1
1
LV 40X15
9
5
4
4
3
3
3
2
2
X
X
X
LH 15X10
2
1
1
X
X
X
X
X
X
X
X
X
LHD 17X17
3
2
2
1
1
1
1
1
X
X
X
X
LHD 20X10
2
1
1
1
1
1
1
1
X
X
X
X
LHD 20X20
4
2
2
2
2
1
1
1
1
1
1
X
LHD 25X15
5
3
2
2
2
2
2
0
0
0
0
X
LHD 25X20
7
3
3
3
2
2
2
2
1
1
0
X
LHD 30X25
8
4
4
3
3
3
3
2
2
1
1
1
LHD 32X15
8
4
4
3
3
3
2
X
X
X
X
X
orientation cable diameter (mm) trunking type
W I R I N G T R U N K I N G S
LHD 40X20
9
5
4
4
3
3
3
2
1
1
X
X
LHD 40X40
22
11
10
9
8
7
7
5
4
4
4
3
LH 60X40
31
16
15
12
11
11
9
7
6
5
5
4
LHD 20X10HF
2
1
1
1
1
1
1
1
X
X
X
X
LHD 20X20HF
4
2
2
2
2
1
1
1
1
1
1
X
LHD 40X20HF
9
5
4
4
3
3
3
2
1
1
X
X
LHD 40X40HF
22
11
10
9
8
7
7
5
4
4
4
3
EKD 80X40HF
40
21
19
16
14
14
12
10
8
7
7
6
PK 110X70 D HF
100
48
44
40
33
31
28
22
19
16
16
13
LZ 15X12
2
1
1
1
X
X
X
X
X
X
X
X
LZK 15X12
3
2
1
1
X
X
X
X
X
X
X
X
LP 80X25
25
13
12
10
9
8
7
6
5
4
4
3
LPK 80X25
25
13
12
10
9
8
7
6
5
4
4
3
LP 35
6
3
3
2
2
2
2
1
1
1
1
1
LR 30
9
5
4
4
3
3
3
2
2
2
2
1
LO 35
2
1
1
X
X
X
X
X
X
X
X
X
LO 50
5
3
2
2
2
2
2
X
X
X
X
X
LO 75
7
3
3
3
2
2
2
X
X
X
X
X
LE 40
8
4
4
3
3
3
3
2
2
X
X
X
LE 60
20
6
6
4
4
4
4
2
2
2
2
2
LE 80
22
6
6
6
6
5
4
2
2
2
2
2
LE100
30
9
9
6
6
6
6
3
3
3
3
3
EKD 80X40
40
21
19
16
14
14
12
10
8
7
7
6
EKD 100X40
50
26
24
20
18
17
15
12
10
9
9
7
EKD 120X40
60
31
29
24
22
20
18
14
12
10
10
8
EKE 60X60
43
23
21
17
16
15
13
10
9
8
8
6
EKE 100X60
77
40
36
31
28
26
23
18
16
13
13
11
EKE 140X60
117
61
55
47
42
40
35
28
24
20
20
16
EKE 180X60
150
78
71
60
54
51
45
36
31
26
26
21
PK 110X70 D
100
48
44
40
33
31
28
22
19
16
16
13
PK 140X70 D
130
63
57
50
43
41
36
29
25
21
21
17
PK 170X70 D
150
81
74
60
56
53
47
37
32
27
27
22
PK 90X55 D
66
21
19
22
14
14
12
10
8
7
7
6
PK 120X55 D
55
32
29
30
22
21
19
15
13
11
11
9
PK 160X65 D
90
63
59
35
44
42
37
29
25
21
21
17
PK 210X70 D
170
65
59
70
45
42
35
30
26
22
22
18
SK 40X20
13
7
6
5
5
4
4
3
3
2
2
2
SK 40X33
20
10
10
8
7
7
6
5
4
3
2
2
The chart counts with 60 % usage of inner trunking cross-section. If the filling is different, you must take into account the way of mounting and the requirements of ČSN 33 2000-4-43, ČSN 33 2000-4-473 and ČSN 33 2000-5-523 standards. These standards define the current-carrying capacity of the conductors and cables respective to their way of mounting, arrangement and surrounding temperature.
52
Parapet trunkings - number of inserted cables usage of trunkings with boxes placement
data cables ∅ 6 mm
power cables ∅ 9,5 mm
10 pcs
3 pcs
16 pcs
9 pcs
13 pcs
8 pcs
data cables ∅ 6 mm
power cables ∅ 9,5 mm
100 pcs
40 pcs
top
15 pcs
5 pcs
middle (SK 40X33)
16 pcs
9 pcs
down
20 pcs
10 pcs
130 pcs
50 pcs
top
20 pcs
10 pcs
middle (SK 40X33)
16 pcs
9 pcs
down
45 pcs
15 pcs
150 pcs
60 pcs
down
16 pcs
top
23 pcs
10 pcs
55 pcs
22 pcs
11 pcs
23 pcs
down
11 pcs
17 pcs
7 pcs
32 pcs
19 pcs
top
20 pcs
8 pcs
40 pcs
15 pcs
down
25 pcs
9 pcs
50 pcs
20 pcs
top
10 pcs
8 pcs
middle
16 pcs
10 pcs
170 pcs
70 pcs
down
12 pcs
8 pcs
top PK 110X70 D middle (SK 40X33) (PK 110X70 D HF) down
PK 140X70 D
PK 170X70 D
PK 90X55 D PK 120X55 D
PK 160X65 D
PK 210X70 D
usage of trunkings without boxes
PK 140X70 D PK 110X70 D HF
PK 90X55 D
PK 120X55 D
The chart counts with 60 % usage of inner trunking cross-section. If the filling is different, you must take into account the way of mounting and the requirements of ČSN 33 2000-4-43, ČSN 33 2000-4-473 and ČSN 33 2000-5-523 standards. These standards define the currentcarrying capacity of the conductors and cables respective to their way of mounting, arrangement and surrounding temperature.
PK 160X65 D
PK 210X70 D
2
W I R I N G T R U N K I N G S
53
WIRING PIPES AND ACCESSORIES
W I R I N G P I P E S
3
Wiring pipes and accessories The pipes and accessories are made in compliance with ČSN EN 61 386-1 ed.2 and IEC 61 386-1 ed.2, specifications and approved documentation. The PVC pipes and accessories passed the test of resistance against spread of flame in compliance with EN IEC 61 386-1. In compliance with ČSN 33 2312 can be used in flammability class A1 - F materials. Polyethylene pipes of type LPE 1 and LPE 2 with low and very low mechanical resistance can be used only for installing on/into class A1 non-inflammable materials. The pipes are intended for installation to the distribution of low voltage. Manufacturer reccommends the assembling of plastic pipes at the temperature over 0 °C. The ČSN 64 0090 standard is applicable for storage. For information on chemical resistance of used material see catalogue pg. 5-4.
Flexible pipes ......…………………….………..................................................………..................................................……….……………………………………….……...... 3-4 very low mechanical resistance (125 N) low mechanical resistance (320 N) medium mechanical resistance (750 N) The electric installation pipes LPFLEX, MONOFLEX and SUPERMONOFLEX with accessories can be installed in places with explosive risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22, the installation must be done in compliance with ČSN EN 60 079-14. Rigid socket pipes ....…....................……….......……....................................................……………………………...……................................................……………........ 3-14 low mechanical resistance (320 N) medium mechanical resistance (750 N) high mechanical resistance (1250 N) Electric installation rigid pipes 15xx, 40xx, 80xx, 15xxHF, 40xxHF, 80xxHF with accessories are possible installed in places with explosive risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22, the installation must be done in compliance with ČSN EN 60 079-14. Used labeling on the product, e.g.:
KOPOS TYP4020 manufacturer type
EN 3341 750N PVC art code material
The pipes are made in dimension compliance with EN standards and passed the mechanical resistance test in compliance with: ČSN EN 61 386-1 a IEC 61 386-1. The pipes of type APAFS, APACS aren’t electric installation pipes in compliance with ČSN EN 61 386-1 ed. 2, but are designed to be us as mechanical protectors of cables. Cable protection KOPOFLEX® and KOPODUR® ..……..............................................................................………….............................................………………….......... 3-21
W I R I N G
Sectional protection KOPOHALF® ........................................................................................................................................................................................................... 3-24 Earthen channel KOPOKAN .................................................................................................................................................................................................................... 3-25 Optical cable protectors - HDPE .……..............................................................................................……………………....................................................…………........ 3-26 Drainage pipe KOPODREN ...................................................................................................................................................................................................................... 3-29 Steel pipes ...........................................................................................………………………………….....................................................………………………………....... 3-30 Aluminium pipes ....................................................................................................................................................................................................................................... 3-39
P I P E S
Flexible metal pipe .................................................................................................................................................................................................................................... 3-41
Pipe tolerance
- rigid: - flexible:
± 10 mm ±1%
Duct tolerance
- KF: - KD: - HDPE:
± 0,5 m ±1% ± 2 mm/m
All pipes and accessories (except for Weicon) are in compliance with EU directives. Flexible pipes of types 14.. and 12.. and rigid pipes of types 15.., 40.., 80.., 15.. HF, 40.. HF including elbows and couplings are in compliance with German electrical Standard .
2
Icons - capture
P
material
UV stable
temperature resistance, scope of application (°C)
color
fire class
dimensions - width (mm)
self-snuffing
thread
mechanical resistance / load limit value (N)
minimum bending radius (mm)
limit of compression strength (kPa)
dimensions - width, height (mm)
classification code according to ÄŒSN EN 61 386-1
package (m; pcs)
area with a risk of explosion
accessories, additional assortment
level of protection - IP classification
dn
outer diameter
functionality during a fire
di
minimal inner diameter
3
halogen-free material
W I R I N G P I P E S
3
3
LPFLEX
- very low mechanical resistance
PVC
-5 - +60°C
A1 - F
30 sec.
125 N/5 cm
11212
For installation into or under the parget. Suitable for mounting into plaster walls and ceilings. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22.
item
conf.
dn
di
L
mm
mm
m
m
100
7200
8595057615991
100
7200
8595057619180
50
5400
8595057651173
with wire
50
5400
8595057651326
100
4000
8595057616004
with wire
100
4000
8595057619197
25
3900
8595568905321
50
4500
8595057651180
50
4500
8595057651333
50
3000
8595057616011
50
3000
8595057619203
50
1600
8595057616028
50
1600
8595057619210
25
1000
8595057619692 8595057619708
description
H100 2316E
H100D
with wire
16
H50 H50D
10,7
H100 H100D 2320 EN
H25 H50D
2325 2332 2340 2350
W I R I N G
20
2313 2316 ČSN 2323
14,1
grey-white RAL 5002
H50 with wire
H50
25
18,3
32
24,3
H25
40
31,2
H25
50
39,6
H50D
with wire
H50 H50D
with wire
H100 H50 H100 H50
18,7
13,5
21,2
16,0
28,5
22,9
grey-white RAL 5002
H100 H50
EAN pg.
25
800
100
4000
8595057600317
50
6300
8595057600324
100
3600
8595057600331
50
3000
8595057600348
100
2800
8595057600355 8595057615366
50
2100
2329
H50
34,5
28,4
50
2000
8595057600379
2336
H50
42,2
35,9
50
1000
8595057600386
P I P E S
4
material
fire class
mechanical resistance
area with a risk of explosion
package
temperature resistance
self-snuffing
classification
color
accessories
3-16 3-17
3-6
MONOFLEX
3
- low mechanical resistance
PVC
-5 - +60°C
A1 - F
30 sec.
320 N/5 cm
22212
For surface installation, into or under parget. Suitable for mounting into hollow walls, plaster walls and ceilings. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22.
item
1416E
conf. F50
black RAL 9005
H50
white RAL 9003
K50 K50D
1420
description
with wire
mm
mm
m
m
50
5400
8595568909664
50
5400
8595057665842
50
5400
8595057616035
50
5400
8595057619753
16
10,7
light grey RAL 7035
50
4500
8595568909671
50
4500
8595057665859
K100
20
K25
14,1
light grey RAL 7035 with wire
4000
8595568910097
25
3900
8595057697461
50
4500
8595057616042
50
4500
8595057619760
F50
black RAL 9005
50
3000
8595568909695
white RAL 9003
50
3000
8595057665866
25
K25
18,3
light grey RAL 7035 with wire
25
2250
8595057699298
50
3000
8595057616059
50
3000
8595057619777
F50
black RAL 9005
50
1600
8595568909718
H50
white RAL 9003
50
1600
8595057665873
15
1620
8595568905413
25
1500
8595057699304
25
1500
8595057619784
50
1600
8595057616066
50
1000
8595568909725
25
1000
8595057693579
25
1000
8595057619715
25
1000
8595057621510
K15
32
K25 with wire
24,3
light grey RAL 7035
K50 F50
black RAL 9005
H25
white RAL 9003
K25
light grey RAL 7035
K25D
ČSN
100
H50
K25D
1450
pg.
black RAL 9005
K50D
1440
EAN
white RAL 9003
K50
1432
L
F50
K50D
1425
di
H50
K50
EN
dn
with wire
F25
black RAL 9005
K25
light grey RAL 7035
40
31,2
50
39,6
25
800
8595568909732
25
800
8595057619722
1413/1
K100
18,7
13,5
100
4000
8595057600416
1416/1
K100
21,2
16,0
100
3600
8595057600423
1423/1
K100
28,5
22,9
100
2800
8595057600430
1429/1
K50
34,5
28,4
50
2000
8595057600447
1436/1
K50
42,2
35,9
50
1000
8595057600454
light grey RAL 7035
material
fire class
mechanical resistance
area with a risk of explosion
package
temperature resistance
self-snuffing
classification
color
accessories
3-16 3-17
W I R I N G P I P E S 3-6
5
3
SUPER MONOFLEX
- medium mechanical resistance
PVC
-5 - +60°C
A1 - F
30 sec.
750 N/5 cm
33212
For surface installation, into or under parget. Suitable for mounting into hollow walls, plaster walls and ceilings. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22.
item
conf. L50
1216E
L50D L50D
with wire
L50
1225
L50D
EN
with wire
L25D L25D
with wire
L25
1250
L25D
L
mm
mm
m
m
50
5400
8595057612914
50
5400
8595057619814
50
4500
8595057612921
50
4500
8595057619821
10,7
20
14,1
25
18,3
32
with wire
L25
1240
di
dark grey RAL 7012
L25
1232
dn
16
with wire
L50
1220
W I R I N G
description
with wire
24,3
40
31,2
50
39,6
EAN pg.
50
3000
8595057612938
50
3000
8595057619838
25
1500
8595057612945
25
1500
8595057619845
25
1000
8595057612952
25
1000
8595057693753
25
800
8595057612969
25
800
8595057621589
3-16 3-17
Connections for flexible pipes ČSN
PVC
-5 - +60°C
A1 - F
item
ČSN
P I P E S
30 sec.
pipe dn
conf.
0216
XX
0223
XX
0229
XX
white RAL 9003
EAN
mm
pcs
21,2
50; 400
8595057600614
28,5
300
8595057600621
34,5
200
8595057600645
Clamps for flexible pipes ČSN
PVC
-5 - +60°C
A1 - F
30 sec.
The clamps are equipped with fastening elements for placing next to each other to create continual row thereof as well as with grooves for installation in supporting trunkings of 5820/.. series (see pg. 2-46). To install, push the pipe between the clamp jaws.
item
di
conf.
mm
ČSN
6
d mm
EAN
mm
pcs
5313
LB
19,4
30
1200
8595057603554
5316
LB
21,5
32
1200
8595057603561
5321
LB
27,3
37
800
8595057603578
5329
LB
35,8
42
600
8595057603585
grey
4,4
material
fire class
mechanical resistance
area with a risk of explosion
height
temperature resistance
self-snuffing
classification
color
package
accessories
MONOFLEX HFPP
3
- low mechanical resistance
PP
-15 - +90°C
A1 - F
30 sec.
320 N/5 cm
22322
Flexible halogen-free self-extinguishing pipe made from PP. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. It may be used in premises where human resources and valuable property protection, damage minimization in case of fire are insisted on, furdn di L conf. EAN item
EN
mm
mm
m
m
1416EHFPP
F100
16
10,7
100
6600
8595057621749
1420HFPP
F100
20
14,1
100
6000
8595057621756
1425HFPP
F50
25
18,2
50
3000
8595057621763
1432HFPP
F50
32
24,2
50
1800
8595057621770
1440HFPP
F25
40
32,4
25
1075
8595057621787
1450HFPP
F25
50
41,2
25
800
8595057621794
black RAL 9005
pg.
3-20
W I R I N G SUPER MONOFLEX HFPP
- medium mechanical resistance
PP
-5 - +90°C
A1 - F
30 sec.
750 N/5 cm
P I P E S
34222
Flexible halogen-free self-extinguishing pipe made from PP. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. It may be used in premises where human resources and valuable property protection, damage minimization in case of fire are insisted on, further on it may be used for machinery, public buildings and railways.
item 1216EHFPP
conf. L100 K100
1220HFPP
K100D
dn
di
L
mm
mm
m
m
grey RAL 7037
16
10,7
100
6600
light grey RAL 9018
100
6000
8595568905352
20
14,1
100
6000
8595568905314
description
with wire
L100 1225HFPP EN
1240HFPP 1250HFPP
pg.
8595057621800
100
6000
8595057621817
100
3600
8595057621824
100
3600
8595057699090
50
1800
8595568905369
50
1800
8595568905376
L50
50
1800
8595057621831
L25
25
1075
8595057699359
50
800
8595057621848
L100 L100D
grey RAL 7037 with wire
K50 1232HFPP
EAN
K50D
L50
with wire
light grey RAL 9018
grey RAL 7037
L25 L50
25
32
18,2
24,2
40
32,4
50
41,2
material
fire class
mechanical resistance
area with a risk of explosion
color
temperature resistance
self-snuffing
classification
halogen-free material
package
25
800
8595057621855
50
700
8595057697881
3-20
accessories
7
3
flexible pipe for a mechanical protection of cables
PA
stable mounting: -40- +120°C
A1 - F
30 sec.
350 N/5 cm
flexible mounting: -5 - +120°C
Flexible UV stable halogenless self-extinguishing pipe made from PA 6. It may be used in premises where human resources and valuable property protection, damage minimization in case of fire are insisted on, further on it may be used for machinery, public buildings and railways.
item
EN
conf.
dn
di
L
mm
mm
m
EAN pg.
APAFS16
F50
15,8
11,8
50
8595057656321
APAFS21
F50
21,2
16,5
50
8595057662179
APAFS28
F50
28,5
22,6
50
8595057667266
APAFS34
F50
34,5
28,8
50
8595057658196
APACS42
F25
42,5
35,2
25
8595057667273
APACS54
F25
54,5
46,5
25
8595057651517
APACS80
F10
79,3
67,3
10
8595057667280
black RAL 9005
3-8 3-9
W I R I N G Accessories for flexible pipes APAFS / APACS
P I P E S
Adaptalok is a system of utilities allowing to terminate and fix the pipe. Utilities allow 45° and 90° tapping and direct threaded termination - M16 - M50 or PG13,5 - PG48. The pipe termination is available as for flange as well. Installation and removal is easy and quick. PA -40 - +105°C IP66 30 sec. 750 N/5 cm black RAL 9005 Utilities are equipped with removal part allowing to remove the termination easily and without breaking. 120 °C for a short term Adaptalok is tested in compliance with ČSN EN 61 386-24. There is possible to assemble it into the space of dangerous area 2 at the environment of hazard explosion and inflammable gases and vapors. Sales from 1 pc. Combination of utilities is driven by outside diameter of used pipe.
Adaptalok direct flange pipe dn
item
conf.
EAN
FB
8595057625495
Adaptalok 90° flange item
conf.
EAN
FB
8595057625464
Adaptalok 45° flange item
Adaptalok termination
conf.
EAN
item
FB
8595057625525
conf.
EAN
A-ES16
FB
8595057625815
A-ES20
FB
8595057625822
mm
16
A16FL
A16FL-90
A16FL-45
20 21
A21FL
FB
8595057625501
A21FL-90
FB
8595057625471
A21FL-45
FB
8595057625532
28
A28FL
FB
8595057625518
A28FL-90
FB
8595057625488
A28FL-45
FB
8595057625549
A-ES28
FB
8595057625839
32
A-ES32
FB
8595057625846
40
A-ES40
FB
8595057625853
80
8
A80FL-90
FB
8595057667297
material
fire class
mechanical resistance
IP classification
UV stable
temperature resistance
self-snuffing
area with a risk of explosion
halogen-free material
color
accessories
3 Adaptalok direct
Adaptalok 90°
Adaptalok 45°
EN pipe dn
item
conf.
EAN
item
conf.
EAN
AM16/16-90
FB
8595057625228
AM21/20-90
FB
item
conf.
EAN
AM16/16-45
FB
8595057625341
8595057625235
AM21/20-45
FB
8595057625358
mm
16
M16x1,5
AM16/16
FB
8595057626676
20
M20x1,5
AM20/20
FB
8595057626133
21
M20x1,5
AM21/20
FB
8595057626683
25
M25x1,5
AM25/25
FB
8595057626140
28
M25x1,5
AM28/25
FB
8595057626690
AM28/25-90
FB
8595057625242
AM28/25-45
FB
8595057625365
34
M32x1,5
AM34/32
FB
8595057626706
AM34/32-90
FB
8595057625259
AM34/32-45
FB
8595057625372
42
M40x1,5
AM42/40
FB
8595057626713
AM42/40-90
FB
8595057625266
AM42/40-45
FB
8595057625389
54
M50x1,5
AM54/50
FB
8595057625150
AM54/50-90
FB
8595057625273
AM54/50-45
FB
8595057625396
ČSN 16
PG13,5
APG16/13
FB
8595057625167
APG16/13-90
FB
8595057625280
APG16/13-45
FB
8595057625402
21
PG16
APG21/16
FB
8595057625174
APG21/16-90
FB
8595057625297
APG21/16-45
FB
8595057625419
28
PG21
APG28/21
FB
8595057625181
APG28/21-90
FB
8595057625303
APG28/21-45
FB
8595057625426
34
PG29
APG34/29
FB
8595057625198
APG34/29-90
FB
8595057625310
APG34/29-45
FB
8595057625433
42
PG36
APG42/36
FB
8595057625204
APG42/36-90
FB
8595057625327
APG42/36-45
FB
8595057625440
54
PG48
APG54/48
FB
8595057625211
APG54/48-90
FB
8595057625334
APG54/48-45
FB
8595057625457
W I R I N G
Adaptalok washer
Adaptalok nut
P I P E S
Dismounting part
EN pipe dn
item
conf.
EAN
item
conf.
EAN
item
conf.
EAN
mm
16
M16x1,5
A-SW/M16
FB
8595057625686
A16RT
FB
8595057625556
21
M20x1,5
A-SW/M20
FB
8595057625693
A21RT
FB
8595057625563
28
M25x1,5
A-SW/M25
FB
8595057625709
A28RT
FB
8595057625570
34
M32x1,5
A-SW/M32
FB
8595057625716
A34RT
FB
8595057625587
42
M40x1,5
A-SW/M40
FB
8595057625723
A42RT
FB
8595057625594
54
M50x1,5
A-SW/M50
FB
8595057625730
A54RT
FB
8595057625600
Nut included.
ČSN 16
PG13,5
A-SW/PG13
FB
8595057625747
A-LN/PG13
FB
8595057625624
A16RT
FB
8595057625556
21
PG16
A-SW/PG16
FB
8595057625754
A-LN/PG16
FB
8595057625631
A21RT
FB
8595057625563
28
PG21
A-SW/PG21
FB
8595057625761
A-LN/PG21
FB
8595057625648
A28RT
FB
8595057625570
34
PG29
A-SW/PG29
FB
8595057625778
A-LN/PG29
FB
8595057625655
A34RT
FB
8595057625587
42
PG36
A-SW/PG36
FB
8595057625785
A-LN/PG36
FB
8595057625662
A42RT
FB
8595057625594
54
PG48
A-SW/PG48
FB
8595057625792
A-LN/PG48
FB
8595057625679
A54RT
FB
8595057625600
halogen-free material UV stable
thread
9
3
LPE-1
- low mechanical resistance
PE
-25 - +90°C
A1
320 N/5 cm
ČSN 22422 EN 22423
Suitable for direct monolithic concreting or under the parget. Pipes of ČSN, EN dimensions are supplied with colour coded stripes for easy identification of individual wiring circuits, tubes can be supplied without the colour coded stripes.
item
conf.
2316E/LPE-1 2320/LPE-1 EN
A100 A100D A100 A100D
dn
di
L
mm
mm
m
m
100
7200
8595057651197
100
7200
8595057651203
100
4000
8595057651234
100
4000
8595057651241
16
with wire with wire
A100 2325/LPE-1
2332/LPE-1
ČSN
description
10,7
20
14,1
25
18,3
EAN pg.
100
3200
8595057651272
100
3200
8595057651289
A50
50
3200
8595568905406
A50
50
1600
8595057657380
50
1600
8595057668843
A100D
A50D
orange
with wire
with wire
32
24,3
2340/LPE-1
A25
40
31,2
25
1000
8595057688452
2316/LPE-1
H100
21,2
16,0
100
3600
8595057603707
2323/LPE-1
H100
28,5
22,9
100
2800
8595057603714
2329/LPE-1
H50
34,5
28,4
50
2000
8595057603721
white RAL 9003
W I R I N G Connectors for LPE ČSN flexible pipes
P I P E S
PE
-25 - +90°C
A1
Connectors are designed to join LPE pipes. pipe dn
item 0216/1 ČSN
0223/1
white RAL 9003
0229/1
10
EAN
mm
pcs
21,2
400
28,5
300
8595057603806
34,5
100; 200
8595057603813
8595057603790
material
temperature resistance
classification
color
fire class
mechanical resistance
halogen-free material
package
accessories
3-20
3-10
LPE-2
3
- very low mechanical resistance
PE
-25 - +90°C
A1
125 N/5 cm
ČSN 11422 EN 11423
Suitable for installing into prefabricated concrete elements. Tubes with the dimension ČSN (not 2336/LPE-2) and EN are standardly delivered with color strips for easy identification of individual wiring circuits. It is also possible to deliver tubes of this dimension without the distinctive strips.
item
conf. A100
2316E/LPE-2
A100D
with wire
F100 F100D
with wire
A100 2320/LPE-2
A100D
with wire
F100 F100D
with wire
A100
EN 2325/LPE-2
A100D
with wire
F100 F100D
with wire
A50 2332/LPE-2
A50D F50
2313/LPE-2
2316/LPE-2 ČSN
L m
m
100
7200
8595057651210
100
7200
8595057651227
100
7200
8595568910127
100
7200
8595568910172
orange 16
10,7
black RAL 9005 orange 20
14,1
black RAL 9005 orange 25
18,3
black RAL 9005 orange 32
24,3
EAN pg.
100
4000
8595057651258
100
4000
8595057651265
100
4000
8595568910134
100
4000
8595568910189
100
3200
8595057651296
100
3200
8595057651302
100
3200
8595568910141
100
3200
8595568910196
50
1600
8595057657397
50
1600
8595057668850
50
1600
8595568910158
50
1600
8595568910202
A25
orange
25
1000
8595057688469
F25
black RAL 9005
25
1000
8595568910165
with wire
A100
orange
H100
white RAL 9003
F100
40
31,2
18,7
13,5
100
4000
8595057614857
100
4000
8595057603646
black RAL 9005
100
4000
8595568910219
A100
orange
100
3600
8595057614864
H100
white RAL 9003
100
3600
8595057603653
F100
black RAL 9005
100
3600
8595568910226
A100
orange
H100
white RAL 9003
F100 A50 2329/LPE-2
H50
white RAL 9003
F50
black RAL 9005
2336/LPE-2
H50
white RAL 9003
2323/LPE-2
di mm
black RAL 9005
F50D 2340/LPE-2
with wire
dn mm
21,2
16,0
100
2800
8595057614871
100
2800
8595057603660
black RAL 9005
100
2800
8595568910233
orange
50
2000
8595057614888
2000
8595057603677
material
temperature resistance
classification
color
fire class
mechanical resistance
halogen-free material
package
28,5
22,9
34,5
28,4
50 50
2000
8595568910240
42,2
35,9
50
1000
8595057603684
3-20
W I R I N G
3-10
P I P E S
accessories
11
3
LPE-1
- UV stable, low mechanical resistance
PE
-25 - +90째C
A1
320 N/5 cm
22423
Flexible UV stable pipe to be suitable for outside installations.
item
conf.
2320/LPE-1 EN
2325/LPE-1 2332/LPE-1
F1.DU
dn
di
L
mm
mm
m
m
100
4000
8595568902498
100
4000
8595568902481
100
3200
8595057699366
100
3200
8595568902504
description
with wire
20
F1.U F1.DU
with wire
F1.U F50DU
black RAL 9005
14,1
EAN pg.
25
18,3
32
24,3
dn
di
L
mm
mm
m
m
100
4000
8595568902535
100
4000
8595568902528
100
3200
8595568902559
100
3200
8595568902542
with wire
F50U
50
1600
8595568902573
50
1600
8595568902566
3-20
W I R I N G LPE-2
P I P E S
- UV stable, very low mechanical resistance
PE
-25 - +90째C
A1
11423
Flexible UV stable pipe to be suitable for outside installations.
item
2320/LPE-2 EN
2325/LPE-2 2332/LPE-2
12
125 N/5 cm
conf. F1.DU
description
with wire
20
F1.U F1.DU
with wire
F1.U F50DU
black RAL 9005
with wire
F50U
14,1
25
18,3
32
24,3
EAN pg.
50
1600
8595057699212
50
1600
8595568902580
material
fire class
classification
UV stable
package
temperature resistance
mechanical resistance
halogen-free material
color
accessories
3-20
SPIROFLEX
3
- low mechanical resistance
PVC
-5 - +60째C
A1 - F
30 sec.
320 N/5 cm
23114
Flexible protective pipe reinforced with hard PVC spiral. Excels in smooth inside surface and very good strength, while the flexibility is guaranteed.
item
conf.
SF16
K30
SF20
K30
SF25
K30
SF32
K30
light grey RAL 7035
dn
di
L
mm
mm
m
m
20,7
16
30
1440
8595057625891
25,0
20
30
1080
8595057625907
30,6
25
30
480
8595057625914
38,0
32
30
420
8595057625921
EAN pg.
3-13
W I R I N G Conduit bushing SPIROFLEX
PVC
-5 - +60째C
item
A1 - F
30 sec.
P I P E S
IP67
pipe di
conf.
mm
For the type of pipe
EAN mm
pcs
SFM20
KB
16
SF16
M20x1,5
25
8595057625938
SFM25
KB
20
SF20
M25x1,5
25
8595057625945
SFM32
KB
25
SF25
M32x1,5
10
8595057625952
SFM40
KB
32
SF32
M40x1,5
10
8595057625969
light grey RAL 7035
material
fire class
mechanical resistance
IP classification
thread
temperature resistance
self-snuffing
classification
color
package
accessories
13
3
Rigid wiring pipes - low mechanical resistance
PVC
-25 - +60°C
A1 - F
30 sec.
320 N/5 cm
22411
Rigid socket pipes are fireproof-tested. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. item
1516E
1520
1525
EN
1532
1540
W I R I N G
1550
1563
conf. HA
white RAL 9003
KA KC
light grey RAL 7035
HA
white RAL 9003
KA KC
light grey RAL 7035
HA
white RAL 9003
KA KC
light grey RAL 7035
HA
white RAL 9003
KA KC
light grey RAL 7035
HA
white RAL 9003
KA KC
light grey RAL 7035
HA
white RAL 9003
KA KC
light grey RAL 7035
HA
white RAL 9003
KA
light grey RAL 7035
dn
di
L
mm
mm
m
m
3
30; 3000
16
13,7
20
17,4
25
22,1
32
28,6
40
36,6
50
45,9
63
58,4
EAN pg.
8595057619067
3
30; 3000
8595057617209
2
20; 2000
8595057617216
3
30; 1890
8595057619074
3
30; 1890
8595057616905
2
20; 1260
8595057613867
3
30; 1260
8595057619081
3
30; 1260
8595057616912
2
20; 840
8595057616882
3
30; 750
8595057619098
3
30; 750
8595057616929
2
20; 500
8595057616875
3
30; 480
8595057619104
3
30; 480
8595057616936
2
20; 320
8595057616943
3
30; 270
8595057619111
3
30; 270
8595057617704
2
20; 180
8595057644946
3
15; 240
8595057657373
3
15; 240
8595057626317
P I P E S
14
material
fire class
mechanical resistance
area with a risk of explosion
package
temperature resistance
self-snuffing
classification
color
accessories
3-16 3-17
3
Rigid wiring pipes - medium mechanical resistance
PVC
-25 - +60°C
A1 - F
30 sec.
750 N/5 cm
33411
Rigid socket pipes are fireproof-tested. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. item
conf. KA
LC KA KC LC KA KC
KA
LC KA KC
20; 2000
8595568903822
30; 3000
8595057617223
2
20; 2000
8595057617230
light grey RAL 7035
3
30; 1890
8595057689954
2
20; 1260
8595568903655
16,9
dark grey RAL 7012
3
30; 1890
8595057617018
2
20; 1260
8595057616899
light grey RAL 7035
3
30; 1260
8595057689930
2
20; 840
8595568902955
21,4
3
30; 1260
8595057616981
2
20; 840
8595057616950
3
30; 750
8595057690011
2
20; 500
8595568902962
dark grey RAL 7012
3
30; 750
8595057617001
2
20; 500
8595057616967
light grey RAL 7035
3
30; 480
8595057689961
2
20; 320
8595568902979
28,0
35,8
dark grey RAL 7012
LC KA
pg.
3
40
LA
4063
2
13,0
EAN
dark grey RAL 7012
32
LA
4050
8595057689602
light grey RAL 7035
KC
4040
30; 3000
dark grey RAL 7012
LC
4032
3
25
LA
EN
m
20
LA
4025
L m
16
LA
4020
di mm
light grey RAL 7035
KC
4016E
dn mm
KC
light grey RAL 7035
50
45,0
3
30; 480
8595057616998
2
20; 320
8595057616974
3
30; 270
8595057690394
2
20; 180
8595568902986 8595057617728
LA
dark grey RAL 7012
3
30; 270
KA
light grey RAL 7035
3
15; 240
8595057696402
LA
dark grey RAL 7012
3
15; 240
8595057626324
63
57,4
3-16 3-17
W I R I N G P I P E S
Rigid wiring pipes - high mechanical resistance
PVC
-25 - +60°C
A1 - F
30 sec.
1250 N/5 cm
44411
Rigid socket pipes are fireproof-tested. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22.
item
8016E 8020 8025 EN 8032 8040
conf. FA FA
L m
m
3
30; 3000
8595057617247
2
20; 2000
8595057617254
3
30; 1890
8595057617087
2
20; 1260
8595057617025
3
30; 1260
8595057617070
2
20; 840
8595057617032
3
30; 750
8595057617063
2
20; 500
8595057617100
3
30; 480
8595057617056
2
20; 320
8595057617049
12,2
20
FC FA FA
di mm
16
FC
FC
dn mm
15,8
25
20,6
black RAL 9005 32
FC FA FC
27,0
40
35,0
EAN pg.
8050
FA
50
44,1
3
30; 270
8595057617711
8063
FA
63
55,4
3
20; 180
8595057626331
material
fire class
mechanical resistance
area with a risk of explosion
package
temperature resistance
self-snuffing
classification
color
accessories
3-16 3-17
15
3
Elbows for EN pipes
PVC
-25 - +60°C
A1 - F
30 sec.
Precision elbows manufactured using injection, with sockets on both sides, designed for 90° bend. Bending radius ensures smooth transition and allows easy retraction of wires and cables. Rigid and flexible pipes can be connected using accessories for rigid pipe. Flexible pipes can also be used to create route bends (different angle than 90°, or pipe arc with a large radius. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. pipe dn
item
conf.
R
mm
16
EAN pcs
4116
pipe dn
item
conf.
R
mm
EAN pcs
FB
10; 480
8595057617735
FB
10; 60
8595057617322
HB
10; 480
8595057643888
HB
10; 60
8595057643918
KA
1400
8595057618442
KA
150
8595057618411
10; 480
8595057617834
10; 60
8595057617346
LA
1400
8595057618435
LA
150
8595057618428
LB
10; 480
8595057617780
LB
10; 60
8595057617339
FB
10; 240
8595057617742
FB
5; 35
8595057617773
HB
10; 240
8595057643895
HB
5; 35
8595057650657
KA
700
8595057618466
KA
80
8595568903419
10; 240
8595057617841
5; 35
8595057617865
55
KB
32
4132
KB
110
conf.
description
FB
color: black RAL 9005
HB
color: white RAL 9003
LA
700
8595057618459
LA
80
8595568904867
KB
color: light grey RAL 7035
LB
10; 240
8595057617797
LB
5; 35
8595057617810
LB
color: dark grey RAL 7012
FB
10; 140
8595057617759
FB
5; 30
8595057617766
HB
10; 140
8595057643901
HB
5; 30
8595057668874
KA
350
8595057618398
5; 30
8595057617872
10; 140
8595057617858
5; 30
8595057617827
LA
350
8595057618404
LB
10; 140
8595057617803
20
W I R I N G
25
4120
4125
70
KB
85
KB
40
50
4140
4150
KB
KB
135
170
LB
Connectors for EN pipes
P I P E S
PVC
-25 - +60°C
A1 - F
30 sec.
Connectors are designed to join pipes. Socketing of pipes and elbows reduces the consumption of connectors when making rigid pipe installations. Rigid and flexible pipes can be connected using accessories for rigid pipe. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. pipe dn
item
conf.
L
mm
16
20
conf.
description
FB
color: black RAL 9005
HB
color: white RAL 9003
KB
color: light grey RAL 7035
LB
color: dark grey RAL 7012
25
32
pcs
0216E
0220
0225
0232
pipe dn
item
conf.
L
mm
EAN pcs
FB
10; 1320 8595057618060
FB
10; 120
8595057618107
HB
10; 1320 8595057643925
HB
10; 120
8595057643963
10; 120
8595057618220
KB
45
10; 1300 8595057618183
40
0240
KB
80
LB
10; 1320 8595057618121
LB
10; 120
8595057618169
FB
10; 840
8595057618077
FB
10; 250
8595057618176
HB
10; 840
8595057643932
HB
10; 250
8595057657359
10; 800
8595057618190
LB
10; 840
8595057618138
FB
10; 480
HB
10; 480 10; 480
8595057618206
LB
10; 480
8595057618145
FB
10; 260
8595057618091
10; 260
8595057643956
10; 260
8595057618213
10; 260
8595057618152
KB
KB
HB KB
50
60
70
LB
16
EAN
50
0250
88
10; 250
8595057618114
LB
10; 250
8595057618237
8595057618084
FB
2; 50
8595057625884
8595057643949
HB
2; 50
8595057657366
2; 50
8595057625860
2; 50
8595057625877
material
fire class
area with a risk of explosion
temperature resistance
self-snuffing
color
63
0263
KB
KB LB
package
105
3
Clamps for EN pipes
PVC
-25 - +60°C
A1 - F
30 sec.
Insulating clamps are designed for fixing the pipe installations on the base surface. Pipes are installed by pushing between the clamp jaws. The clamps are equipped with elements for placing next to each other to create a continuous series of tubes, and also grooves for installation in supporting trunkings of 5820/ .. (See page 2-46). Clamps can be combined into one line. The connection can be made for clamps of different sizes. Rigid and flexible pipes can be connected using accessories for rigid pipe. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. pipe dn
item
d inlet for mounting
conf.
mm
16
20
25
32
40
50
63
EAN
mm
5316E
5320
5325
5332
5340
5350
5363
FB
black RAL 9005
HB
white RAL 9003
KB
light grey RAL 7035
LB
dark grey RAL 7012
FB
black RAL 9005
HB
white RAL 9003
KB
light grey RAL 7035
pcs
10; 2500 8595057619340 10; 100
8595057643833
10;100;920 8595057619357
10; 100
8595057619364
10; 1900 8595057618015 4,3 x 6,5
10; 1900 8595057643840 10;100;720 8595057617896
LB
dark grey RAL 7012
10; 1900 8595057617957
FB
black RAL 9005
10; 1280 8595057618022
HB
white RAL 9003
10; 1280 8595057643857
KB
light grey RAL 7035
10; 1280 8595057617902
LB
dark grey RAL 7012
10; 1280 8595057617964
FB
black RAL 9005
HB
white RAL 9003
10; 840
8595057618039
10;100;740 8595057643864
KB
light grey RAL 7035
10; 100
8595057617919
LB
dark grey RAL 7012
10; 840
8595057617971
FB
black RAL 9005
10; 520
8595057618046
HB
white RAL 9003
10; 520
8595057643871
KB
light grey RAL 7035
LB
dark grey RAL 7012
FB
black RAL 9005
HB
white RAL 9003
10;100;400 8595057617926
5,0 x 10,0
10; 520
8595057617988
10; 420
8595057618053
10; 420
8595057657045
KB
light grey RAL 7035
LB
dark grey RAL 7012
10; 420
8595057617995
FB
black RAL 9005
10; 240
8595057657496
HB
white RAL 9003
10; 300
8595057657502
KB
light grey RAL 7035
10; 240
8595057657519
LB
dark grey RAL 7012
10; 240
8595057657526
material
fire class
area with a risk of explosion
temperature resistance
self-snuffing
color
10;100;350 8595057617933
W I R I N G P I P E S
package
17
3
Halogen-free rigid wiring pipes - low mechanical resistance
PPO
-45 - +90°C
A1 - F
30 sec.
320 N/5 cm
22521
Halogen-free rigid socket pipe suitable for housing and industrial distribution in hospitals, schools, IT centers, etc. Suitable for environments with increased need of people and equipment protection. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. The black pipes are UV-stabilized.
item
conf.
1516EHF 1520HF 1525HF EN
1532HF 1540HF 1550HF 1563HF
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
dn
di
L
mm
mm
m
m
3
30; 3000
8595057626423
3
30; 3000
8595057631854
3
30; 1890
8595057626430
3
30; 1890
8595057631861
16
13,7
20
17,4
25
22,1
32
28,6
40
36,0
50
45,5
63
58,2
EAN pg.
3
30; 1260
8595057626966
3
30; 1260
8595057631878
3
30; 750
8595057626973
3
30; 750
8595057631885
3
30; 480
8595057626447
3
30; 480
8595057631892
3
30; 270
8595057626454
3
30; 270
8595057631908
3
15; 240
8595057631489
3
15; 240
8595057631915
3-19 3-20
W I R I N G Halogen-free rigid wiring pipes - medium mechanical resistance
P I P E S
PPO
-45 - +90°C
A1 - F
750 N/5 cm
33521
Halogen-free rigid socket pipe suitable for housing and industrial distribution in hospitals, schools, IT centers, etc. Suitable for environments with increased need of people and equipment protection. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. The black pipes are UV-stabilized.
item
conf.
4016EHF 4020HF 4025HF EN
4032HF 4040HF 4050HF 4063HF
18
30 sec.
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
FA
black RAL 9005
KA
light grey RAL 7035
dn
di
L
mm
mm
m
m
3
30; 3000
8595057688254
3
30; 3000
8595057690868
3
30; 1890
8595057688261
3
30; 1890
8595057690875
16
13,0
20
16,9
25
21,4
32
27,8
40
35,4
50
44,3
63
58,0
EAN pg.
3
30; 1260
8595057688278
3
30; 1260
8595057690882
3
30; 750
8595057688285
3
30; 750
8595057690899
3
30; 480
8595057688292
3
30; 480
8595057690905
3
30; 270
8595057688308
3
30; 270
8595057690912
3
15; 240
8595057688315
3
15; 240
8595057690929
3-19 3-20
material
fire class
mechanical resistance
area with a risk of explosion
UV stable
package
temperature resistance
self-snuffing
classification
halogen-free material
color
accessories
3
Halogen-free rigid wiring pipes - high mechanical resistance
PPO
-45 - +90°C
A1 - F
30 sec.
1250 N/5 cm
44521
Halogen-free rigid socket pipe suitable for housing and industrial distribution in hospitals, schools, IT centers, etc. Suitable for environments with increased need of people and equipment protection. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. The black pipes are UV-stabilized.
item
EN
conf.
dn
di
L
mm
mm
m
m
EAN pg.
8016EHF
FA
16
12,2
3
30; 3000
8595057688322
8020HF
FA
20
15,8
3
30; 1890
8595057688339
8025HF
FA
25
20,6
3
30; 1260
8595057688346
8032HF
FA
32
26,6
3
30; 750
8595057688353
8040HF
FA
40
34,4
3
30; 480
8595057688360
8050HF
FA
50
43,2
3
30; 270
8595057688377
8063HF
FA
63
55,4
3
15; 240
8595057688384
black RAL 9005
3-19 3-20
W I R I N G Elbows for halogen-free EN pipes
PPO
-45 - +90°C
A1 - F
30 sec.
Precision elbows manufactured using injection, with sockets on both sides, designed for 90° bend. Bending radius ensures smooth transition and allows easy retraction of wires and cables. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. Elbows in black are UV stable.
pipe dn
item
R
conf.
mm
16 20 25 32 40 50
mm
4116HF 4120HF 4125HF 4132HF 4140HF 4150HF
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
55 70 85 110 135 170
P I P E S
EAN pcs
10; 480
8595057626461
10; 480
8595057629288
10; 240
8595057626478
10; 240
8595057629295
10; 140
8595057626256
10; 140
8595057629301
10; 60
8595057626263
10; 60
8595057629318
5; 35
8595057626485
5; 35
8595057651166
5; 30
8595057626492
5; 30
8595057699281
material
fire class
mechanical resistance
area with a risk of explosion
UV stable
package
temperature resistance
self-snuffing
classification
halogen-free material
color
accessories
19
3
Connectors for halogen-free EN pipes
PPO
-45 - +90°C
A1 - F
30 sec.
Connectors are designed to join pipes. Socketing of pipes and elbows reduces the consumption of connectors when making rigid pipe installations. Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. Connectors in black are UV stable. pipe dn
item
L
conf.
mm
EAN
mm
16
0216HF
20
0220HF
25
0225HF
32
0232HF
40
0240HF
50
0250HF
63
0263HF
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
FB
black RAL 9005
KB
light grey RAL 7035
45
pcs
10; 1320
8595057626508
10; 1300
8595057631922
10; 840
8595057626515
10; 800
8595057631939
10; 480
8595057626270
10; 480
8595057631946
10; 260
8595057626287
10; 260
8595057631953
10; 120
8595057626522
10; 120
8595057631960
10; 180
8595057626539
10; 180
8595057631977
2; 50
8595057629356
2; 50
8595057631984
50 60 70 80 88 105
W I R I N G Clamps for halogen-free EN pipes
P I P E S
PPO
-45 - +90°C
A1 - F
30 sec.
Insulating clamps are designed for fixing the pipe installations on the base surface. Pipes are installed by pushing between the clamp jaws. The clamps are equipped with elements for placing next to each other to create a continuous series of tubes, and also grooves for installation in supporting trunkings of 5820/ .. (see page 2-46). Possibility to install in places with risk of flammable gases and vapor – danger zone 2, with explosive risk of dust – danger zone 22. Clamps in black are UV stable. pipe dn
item
d inlet for mounting
conf.
mm
16
5316EHF
20
5320HF
25 32 40 50 63
20
mm
5325HF 5332HF 5340HF 5350HF 5363HF
FB
black RAL 9005
KB
light grey RAL 7035
EAN pcs
10; 2500
8595057626546
10; 100; 920 8595057631809
FB
black RAL 9005
KB
light grey RAL 7035
10; 1900
8595057631816
FB
black RAL 9005
10; 1280
8595057626294
KB
light grey RAL 7035
10; 1280
8595057631823
FB
black RAL 9005
10; 840
8595057626300
KB
light grey RAL 7035
10; 840
8595057631830
FB
black RAL 9005
10; 520
8595057626560
KB
light grey RAL 7035
10; 520
8595057631847
FB
black RAL 9005
10; 420
8595057626577
KB
light grey RAL 7035
10; 420
8595057632769
FB
black RAL 9005
10; 240
8595057688759
KB
light grey RAL 7035
10; 240
8595057688742
4,4 x 6,4
5,4 x 10,0
10; 100; 720 8595057626553
material
fire class
area with a risk of explosion
UV stable
package
temperature resistance
self-snuffing
halogen-free material
color
accessories
KOPOFLEX®
3
- flexible doublecoat corrugated pipe
HDPE
storage: -45- +60°C
A1
450 N/20 cm
IP40
assembly: -5 - +60°C
Halogen-free flexible double-coated pipe designed for mechanical protection of all kinds of power and data wiring. The pipes are made in compliance with ČSN EN 61 386-24. The pipe is available in form of a bar, the coupling is put on one end of it. When using a sealing ring, the protection class is IP 67. In case of mechanical compaction of layers above the protector, take care not to exceed the value of the load capacity of the protector - see catalogue PIPE PROTECTORS.
item
conf.
KF 09090
BA
red
50
3000
50
3000
25
2625
CB
blue
40
32
230
in stock
EAN
- min. 1000 m
8595057619425
8595057606333
8595057615625
dimension (cm)
65 x 30 50 x 25
pg.
8595057621107
- min. 1000 m
8595057619432
8595057608641
DA
green
50
3000
EA
yellow
50
3000
FA
black
50
3000
8595057616226
AA
orange
50
1800
- min. 1000 m
8595057619241
BA
red
50
1800
8595057606340
50
1800
8595057655935
25
1575
50
1800
CB
blue
50
41
350
DA
green
EA
yellow
50
1800
FA
black
50
1800
AA
orange
50
BA
red
50
CB
blue
63
52
350
80 x 35 70 x 25 80 x 35
95 x 35
25
green
50
EA
yellow
50
FA
black
50
BA
red
50
CB
65 x 30
50
DA
50
blue 75
61
350
85 x 30 95 x 35
110 x 40
25
DA
green
EA
yellow
50
90 x 35
50 110 x 40
8595057655928
- min. 1000 m
8595057697270
8595057606357
8595057616233
- min. 1000 m
8595568912442
8595057643703
8595057644977
8595057644984
- min. 1000 m
8595568915221
8595057668911
8595057650527
8595057643710
8595057644991
8595057645004
- min. 1000 m
8595057684027
8595057651449
FA
black
50
8595057650534
BA
red
50
8595057643727
CA
blue
8595057650435
FA
black
50
8595057650442
AA
orange
50
- min. 1000 m
8595057619234
BA BB KF 09110
m
3000
CA KF 09075
m
50
CA KF 09063
L mm
orange
CA KF 09050
di mm
AA CA KF 09040
dn mm
CA CB
90
75
400
110
94
400
120 x 45
120 x 65
8595057606364
25
105 x 50
8595057692824
50
120 x 65
8595057615649
25
105 x 50
8595057655911
- min. 1000 m
8595568915184
8595057651456
8595057616240
50
red blue
50
DA
green
50
EA
yellow
50
FA
black
50
KF 09120
BA
red
120
100
500
50
150 x 60
8595057618329
KF 09125
BA
red
125
108
500
50
160 x 60
8595057618336
50
160 x 80
8595057643741
25
160 x 45
8595057647800
50
160 x 80
8595057647787
25
160 x 45
8595057647794
160 x 80
8595057650565
8595057618343
8595057619517
8595568903587
8595057688568
BA BB KF 09160
CA CB
KF 09175 KF 09200
red blue
160
136
650
FA
black
50
BA
red
50
FA
black
BB
red
FB
black
175 200
150 172
700 850
50 25 25
material
fire class
IP classification
color
temperature resistance
mechanical resistance
halogen-free material
bending radius
120 x 65
200 x 65 170 x 70
package
standard
W I R I N G
3-24
P I P E S
to order, delivery time 3 weeks accessories
21
3
KOPOFLEX®
- UV-stabilized flexible doublecoat corrugated pipe
HDPE
storage: -45- +60°C
A1
450 N/20 cm
IP40
assembly: -5 - +60°C
Halogen-free UV stable flexible double-coated pipe designed for mechanical protection of all kinds of power and data wiring. The pipes are made in compliance with ČSN EN 61 386-24. The pipe is available in form of a bar, the coupling is put on one end of it. When using a sealing ring, the protection class is IP 67. In case of mechanical compaction of layers above the protector, take care not to exceed the value of the load capacity of the protector - see catalogue PIPE PROTECTORS.
item
conf. UVBA
KF 09040
KF 09050
KF 09063
W I R I N G
KF 09075
KF 09090
KF 09110
P I P E S
22
KF 09160
dn
di
mm
mm
L mm
red 40
50
3000
blue
50
3000
UVFA
black
50
3000
UVBA
red
50
1800
UVCA
blue
50
1800
UVFA
black
50
1800
UVBA
red
50
blue
UVFA
black
50
UVBA
red
50
blue
UVFA
black
75
52
350
UVCA
UVCA
63
41
230
m
UVCA
50
32
in stock
m
61
350
350
UVFA
black
50
UVBA
red
50
90
110
75
blue black
50
UVBA
red
50 136
400
650
8595057698147
80 x 35
- min. 1000 m 8595057698192
8595057698178
- min. 1000 m 8595057698222
8595057698208
- min. 1000 m 8595057698345 110 x 45
- min. 1000 m 8595057698352
3-24
8595057698338
- min. 1000 m 8595057698246
50
UVFA
160
94
400
UVCA
blue
50
red
black
- min. 1000 m 8595057698161 - min. 1000 m 8595057698185
90 x 35
50
blue
UVFA
65 x 30
50
UVBA
UVCA
pg.
- min. 1000 m 8595057698154
- min. 1000 m 8595057698215
50
UVCA
EAN
dimension (cm)
120 x 45
- min. 1000 m 8595057698253
8595057698239
- min. 1000 m 8595057698277
50
120 x 65
- min. 1000 m 8595057698284
8595057698260
- min. 1000 m 8595057698376
50
160 x 80
- min. 1000 m 8595057698383
50
8595057698369
material
fire class
IP classification
UV stable
bending radius
standard
temperature resistance
self-snuffing
halogen-free material
color
package
to order, delivery time 3 weeks
accessories
KOPODUR®
3
- rigid doublecoat corrugated pipe
HDPE
storage: -45- +60°C
A1
450 N/20 cm
IP40
assembly: -5 - +60°C
Halogen-free rigid double-coated pipe designed for mechanical protection of all kinds of power and data wiring. The pipes are made in compliance with ČSN EN 61 386-24. The pipe is available in form of a bar, the coupling is put on one end of it. The connection is sealed dust/sand resistant. When using a sealing ring, the protection class is IP 67. In case of mechanical compaction of layers above the protector, take care not to exceed the value of the load capacity of the protector - see catalogue PIPE PROTECTORS.
item
conf.
KD 09040
BC BC
red
KD 09050
CC
blue
FC
black
KD 09063
BC
red
BC
red
CC
blue
BC
red
CC
blue
KD 09075
KD 09090
KD 09110
m
dimension (cm)
40
32
6
432
6
360
50
41
6
360
6
360
63
52
6
312
6
312
6
312
6
312
6
312
75
90
61
75
in stock
EAN
45 x 45 x 605
- min. 1000 m
8595057643758
8595057643765
82 x 66 x 605
8595057650459
- min. 1000 m
8595057689404
80 x 52 x 605 104 x 88 x 607
120 x 76 x 607
pg.
8595057643772
8595057643789
8595057650121
8595057643796
- min. 1000 m
8595057651401
black
6
312
- min. 1000 m
8595057683853
red
6
462
8595057606449
CC
blue
6
216
8595057655942
3
231
8595057616271
6
216
6
212
6
288
6
306
FA FC
KD 09125
BC
BA
KD 09200
L m
FC
BC
KD 09175
di mm
BC
KD 09120
KD 09160
red
dn mm
110
94
120
100
125
108
black red red
112 x 95 x 610
8595057656451
112 x 128 x 610
- min. 1000 m
8595057618282
8595057619876
112 x 71 x 610
- min. 1000 m
8595057618299
CC
blue
6
288
- min. 1000 m
8595057688049
BC
red
6
198
8595057643819
6
198
8595057647848
6
198
6
306
6
120
6
120
CC
blue
FC
black
BA
red
175
150
red
200
175
BA BC
160
136
117 x 83 x 610 108 x 126 x 615 122 x 74 x 615
8595057651418
- min. 1000 m
8595057618626
8595057618633
8595057618312
material
fire class
IP classification
color
standard
temperature resistance
mechanical resistance
halogen-free material
package
to order, delivery time 3 weeks
3-24
W I R I N G P I P E S
accessories
23
3
Accessories for corrugated pipes KOPOFLEX® and KOPODUR®
PA
-40 - +105°C 120 °C for a short term
Couplings - slip-over couplings are the same for both types of pipes and are used to join the pipes. Sealing rings - the same for both types of pipes and are used to seal the joint to prevent it against humidity and water. Closing plugs - for blinding of backup lines and for temporary blinding of pipes when installing. Distance spacers - for position fixation of several pipes in one excavation. Distance spacers are for fixation 8 pipes and spacer can be split for fixation 2, 4 and 6 pipes. Per order only.
Couplings pipe dn
item
Sealing rings
conf.
EAN
item
Closing plugs
conf.
EAN
item
Distance spacers
conf.
EAN
item
conf.
EAN
mm
W I R I N G
40
02040
FA
8595057612082
16040
FB
8595057606609
17040
BB
8595057606661
50
02050
FA
8595057613249
16050
FB
8595057606616
17050
BB
8595057606678
07050/8
FB
8595057615113
63
02063
FA
8595057650466
16063
FB
8595057606623
17063
BB
8595057606685
07063/8
FB
8595057626225
75
02075
FA
8595057650473
16075
FB
8595057606630
17075
BB
8595057606692
07075/8
FB
8595057622111
90
02090
FA
8595057650480
16090
FB
8595057609167
17090
BB
8595057609204
07090/8
FB
8595057658035
16110
FB
8595057606647
07110/8
FB
8595057610538
110
02110
FA
8595057612075
17110
BB
8595057606708
120
02120
FB
8595057629134
17120
BB
8595057612198
125
02125
FB
8595057699946
17125
BB
8595057606715
07125/8
FB
8595057635036
160
02160
FA
8595057650497
17160
BB
8595057609228
07160/8
FB
8595057635050
175
02175
FB
8595057617421
17175
BB
8595057609235
200
02200
FB
8595057617438
17200
BB
8595057610798
07200/8
FB
8595057658059
KOPOHALF®
- divided cable duct
P I P E S
HDPE
A1
06110/2 - 450 N/20 cm
IP30
06160/2 - 750 N/20 cm
A system of divided cable ducts is suitable mainly for a protection of underground cable laying and for a laying-out of the energy and communication lines. Another possible application is a protection of already installed underground cables. The protectors consist of two identical parts. When installing, the cables are put in the bottom part and then the top part is snapped to the bottom one. The divided cable ducts are manufactured and tested in accordance with standard ČSN EN 61 386-24. Connecting of protectors is performed by overlapping joined lower parts with an upper part at length of approximately 30 cm.
item
06110/2
06160/2
24
storage: -45- +75°C assembly: -5 - +75°C
conf.
description
dn
di
L
mm
mm
m
m
EAN
BA
in distributed position
red
3
162
8595057651814
BAD
interlocked
red
3
105
8595057693371
CA
in distributed position
blue
3
162
8595057651821
CAD
interlocked
blue
3
105
8595057693388
EA
in distributed position
yellow
3
162
8595057695924
FA
in distributed position
black RAL 9005
3
162
8595057688506
BA
in distributed position
red
3
72
8595057651791
3
45
8595057693395
3
72
8595057651807
110
100
BAD
interlocked
red
CA
in distributed position
blue
CAD
interlocked
blue
3
45
8595057693401
EA
in distributed position
yellow
3
72
8595057695931
160
material
fire class
IP classification
color
temperature resistance
mechanical resistance
halogen-free material
package
138
KOPOHALF®
3
- divided cable duct
PVC
storage: -25- +60°C
30 sec.
A1 - F
750 N/20 cm
IP30
assembly: -15 - +60°C
A system of divided cable ducts is suitable mainly for a protection of underground cable laying and for a laying-out of the energy and communication lines. Another possible application is a protection of already installed underground cables. The protectors consist of two identical parts. When installing, the cables are put in the bottom part and then the top part is snapped to the bottom one. The divided cable ducts are manufactured and tested in accordance with standard ČSN EN 61 386-24. Connecting of protectors is performed by overlapping joined lower parts with an upper part at length of approximately 30 cm.
item
06110P/2
KOPOKAN
conf.
description
dn
di
L
mm
mm
m
m
EAN
BA
in distributed position
red
3
162
8595568922007
BAD
interlocked
red
3
105
8595568922014
CA
in distributed position
blue
3
162
8595568922021
CAD
interlocked
blue
3
105
8595568922038
110
100
- earthen channel
PVC
-5 - +60°C
A1 - F
IP30
30 sec.
Earthen channels are intended for mechanical protection of installation of engineering networks to be loaded under ground. By its technical parameters those fully replace the earlier used concrete channels. There is possible to use them for additional protection already installed earthen engineering networks. Earthen channels are delivered including the red lid (KOPOKAN 4 is delivered just in black color). Connected using connectors and folding the lid over, thus interconnecting the individual parts. Strength limit on compression tested on length 300 mm. Earthen channels are manufactured according to ČSN EN 61 386-1 and ČSN EN 61 386-24.
item
conf. CD
grey body / blue lid
ZD
grey body / red lid
KOPOKAN 2
ZD
KOPOKAN 3 KOPOKAN 4
KOPOKAN 1
W I R I N G
P
a
b
L
mm
mm
m
m
2
140
2
140
EAN kPa
483
pg.
8595568915474
100
100
grey body / red lid
120
100
2
162
223
8595568905123
ZD
grey body / red lid
130
140
2
224
285
8595568905130
ZD
black
200
125
2
70
204
8595568905147
8595568905116 3-25
P I P E S
connection for KOPOKAN
PVC
-5 - +60°C
A1 - F
30 sec.
Connector is used to connect the ground channels. It provides a straight direction.
item
material temperature resistance
conf.
L
H
S
mm
mm
m
pcs
EAN
SPOJKA K1
ZB
120
80
100
1; 50
8595568905154
SPOJKA K2
ZB
135
80
100
1; 50
8595568905161
SPOJKA K3
ZB
151
80
100
1; 50
8595568905178
SPOJKA K4
ZB
221
80
120
1; 35
8595568905185
fire class self-snuffing
IP classification color
package P
limit of compression strength
accessories
25
3
Optical cable protectors HDPE
HDPE
-5 - +50°C
A1
750 N/20 cm
Single-coated pipes designed to protect optical cables. Cable protectors there is possible to deliver with inner wall to be lubrificated by mineral oil. For larger volumes different color versions (beyond presented versions), labeling, number of differential stripes, denticular inner surface or inner diameter size (material thickness) can be ordered based on customer needs and specifications. Shock resistance: N (normal, ÄŒSN EN 61 386-24) Bend resistance: flexible The protectors are tested under pressure of 1,5 MPa for the time of 1 hour. The packaging on wooden drums and pallets for unwinding drums is delivered just upon previous order according to the customers's specification.
item
conf.
description
AS100
06025
06032
P I P E S
in stock
pg.
orange
100
- min. 3000 m
red
100
- min. 3000 m
100
- min. 3000 m
DS100
green
100
harness
yellow
25
20
100
EAN
mm
blue
400
- min. 3000 m - min. 3000 m
FS100
black
100
- min. 3000 m
8595568903730
KS100
light grey
100
8595568903860
LS100
dark grey
100
- min. 3000 m
1750
- min. 3000 m
8595057657311
100
8595057657328
1750
- min. 3000 m
8595057656383
100
8595057656390
1750
- min. 3000 m
8595057657441
100
- min. 3000 m
AB
drum
AS100
harness
BB
drum
BS100
harness
CB
drum
CS100
harness
DB
drum
DS100
harness
EB
drum
ES100
harness
FB
drum
FS100
harness
KB
drum
KS100
harness
LB
drum
LS100
harness
orange red blue green 32
26 / 27
yellow black light grey dark grey
1750
- min. 3000 m
100
- min. 3000 m
400
- min. 3000 m
8595057656406
100
8595057656413
1750
- min. 3000 m
1750
100
1750
- min. 3000 m
8595057665552
100
1750
- min. 3000 m
100
8595057665569
1750
- min. 1750 m
8595057655393
2000
- min. 1750 m
8595057658226
AB
drum
AP
harness - pallet
AS100
harness
100
8595057655409
BB
drum
1750
- min. 1750 m
8595057655416
100
8595057655423
300
- min. 1750 m
8595568903303
BS300
orange
red
harness
CB
drum
1750
- min. 1750 m
8595057655430
CP
harness - pallet
2000
- min. 1750 m
8595057696242
100
8595057655447
300
- min. 1750 m
8595568903457
- min. 1750 m
8595057655454
CS100 CS300
drum
DP
harness - pallet
DS300
blue
harness
DB DS100
40 green
harness
33 / 34 / 35
1750 2000
400
- min. 1750 m
100
8595057655461
300
- min. 1750 m
8595568903297 8595057655478
EB
drum
1750
- min. 1750 m
EP
harness - pallet
2000
- min. 1750 m
ES100 ES300
yellow
harness
100
8595057655485
300
- min. 1750 m
8595568903716
FB
drum
1750
- min. 1750 m
8595057655492
FP
harness - pallet
2000
- min. 1750 m
8595057665637
100
8595057655508
300
- min. 1750 m
FS100 FS300
26
L m
BS100
BS100
06040
di mm
CS100 ES100
W I R I N G
dn mm
black
harness
material
fire class
halogen-free material
bending radius
standard
temperature resistance
mechanical resistance
color
package
to order, delivery time 3 weeks
accessories
3-27 3-28
item
conf.
description
L m
in stock
pg.
drum
1750
- min. 1750 m
harness - pallet
2000
- min. 1750 m
light grey
harness
KS300
40
LB
drum
LP
harness - pallet
33 / 34 / 35
LS300
100
8595057655546
- min. 1750 m
8595568903440
- min. 1750 m
8595057655553
1750
400
dark grey
- min. 1750 m
100
8595057655560
300
- min. 1750 m
8595568903433
1250
- min. 2500 m
8595057657298
1250
- min. 2500 m
AB
drum
AP
harness - pallet
AS100
harness
100
BB
drum
1250
- min. 2500 m
1250
- min. 2500 m
orange
8595057657304
BP
harness - pallet
BS100
harness
100
8595057699540
CB
drum
1250
- min. 2500 m
8595057689978
CP
harness - pallet
1250
- min. 2500 m
8595057689411
CS100
harness
100
8595057691070
1250
- min. 2500 m
DB
drum
DP
harness - pallet
DS100
harness
EB
drum
EP
harness - pallet
ES100
red
blue
green 50
41 / 44
1250
- min. 2500 m
100
- min. 2500 m
1250
500
- min. 2500 m
harness
100
- min. 2500 m
FB
drum
1250
- min. 2500 m
8595568912558
FP
harness - pallet
1250
- min. 2500 m
8595057698475
FS100
harness
100
8595057665576
KB
drum
1250
- min. 2500 m
1250
- min. 2500 m
black
light grey
KP
harness - pallet
KS100
harness
100
LB
drum
1250
- min. 2500 m
LP
harness - pallet
1250
- min. 2500 m
LS100
harness
100
dark grey
3-27 3-28
- min. 2500 m
1250
yellow
3
8595057655539
300 2000
harness
EAN
mm
KB
LS100
06050
di mm
KP KS100 06040
dn mm
8595057689923
8595057665583
W I R I N G P I P E S
Screw connectors for optical cable protectors
PP
-5 - +50째C
A1
The connector is designed to join HDPE optic cable protector when routing and ensures a perfect connection.
item
pipe dn
conf.
mm
EAN pcs
05025
KB
25
1
8595568905451
05030
KB
32
1
8595057657335
05040
KB
40
1
8595057606821
05050
KB
50
1
8595057651579
grey
material
fire class
halogen-free material
bending radius
standard
temperature resistance
mechanical resistance
color
package
to order, delivery time 3 weeks
accessories
27
3
Push connectors for optical cable protectors
PP
-5 - +50째C
A1
The connector is designed to join HDPE optic cable protector when routing and ensures a perfect connection. The pipe is pushed onto the connector.
item
pipe dn
conf.
05033
KB
05043
KB
05053
KB
grey
EAN
mm
pcs
32
1
8595057657694
40
1
8595057657700
50
1
8595057657717
Fittings for optical cable protectors
W I R I N G
PP
-5 - +50째C
A1
The fitting is used to end the routing.
item
P I P E S
pipe dn
conf.
EAN
mm
pcs
05024
KB
25
1
8595568905468
05031
KB
32
1
8595057657342
05041
KB
40
1
8595057629271
05051
KB
50
1
8595057651586
grey
Vented fittings for optical cable protectors
PP
-5 - +50째C
A1
Vented fitting is used to check the installed lines using compressed air.
item
28
05032
KB
05042
KB
material
fire class
temperature resistance
color
pipe dn
conf.
black RAL 9005
package
EAN
mm
pcs
32
1
8595057667181
40
1
8595057635319
KOPODREN
3
- drainage pipe
PE
KOPODREN pipeline is used in all areas of drain technics, e.g. draining of buildings, deep engineering constructions, sport places building, in agriculture, gardens, to drain areas of use, or to temporary draining of work sites. The pipes have low weight and high chemical resistance. The construction of the pipe ensures high flexibility. This is a major advantage when installing as well as meeting the requirement of small bend radius. The pipe joints are protected against pull-off and are designed to join using a snap.
item
conf.
dn
L
mm
m
EAN pg.
KOPODREN 50
E50
50
50
8595057621619
KOPODREN 65
E50
65
50
8595057621626
KOPODREN 80
E50
80
50
8595057621633
KOPODREN 100
E50
100
50
8595057621640
KOPODREN 125
E50
125,5
50
8595057621657
KOPODREN 160
E50
159,5
50
8595057621664
KOPODREN 200
E45
199,5
45
8595057621671
yellow
3-29
W I R I N G KOPODREN drainage pipe accessories connectors pipe dn
item
T joints
conf.
EAN
item
reducers
conf.
EAN
item
90째 elbows
conf.
EAN
item
conf.
EAN
mm
50
KN-S 50
FB
8595057622630
KN-T 50
FB
8595057622913
KN-R 65/50
FB
8595057622579
65
KN-S 65
FB
8595057622647
KN-T 65
FB
8595057622920
KN-R 80/65
FB
8595057622586
80
KN-S 80
FB
8595057622654
KN-T 80
FB
8595057622937
KN-R 100/80
FB
8595057622593
KN-K90 80
FB
8595057622869
100
KN-S 100
FB
8595057622661
KN-T 100
FB
8595057622944
KN-R 125/100
FB
8595057622609
KN-K90 100
FB
8595057622876
125,5
KN-S 125
FB
8595057622678
KN-T 125
FB
8595057622951
KN-R 160/125
FB
8595057622616
KN-K90 125
FB
8595057622883
159,5
KN-S 160
FB
8595057622685
KN-T 160
FB
8595057622968
KN-R 200/160
FB
8595057622623
KN-K90 160
FB
8595057622890
199,5
KN-S 200
FB
8595057622692
KN-T 200
FB
8595057622975
KN-K90 200
FB
8595057622906
end flaps pipe dn
plugs
item
conf.
EAN
50
KN-KK 50
FB
8595057623057
65
KN-KK 65
FB
8595057623064
80
KN-KK 80
FB
100
KN-KK 100
125,5
item
45째 branches
conf.
EAN
KN-Z 50
FB
8595057622982
KN-Z 65
FB
8595057622999
8595057623071
KN-Z 80
FB
FB
8595057623088
KN-Z 100
KN-KK 125
FB
8595057623095
159,5
KN-KK 160
FB
199,5
KN-KK 200
FB
item
P I P E S
90째 bends
conf.
EAN
item
conf.
EAN
KN-OD45 50
FB
8595057622708
KN-OB90 50
FB
8595057622777
KN-OD45 65
FB
8595057622715
KN-OB90 65
FB
8595057622784
8595057623002
KN-OD45 80
FB
8595057622722
KN-OB90 80
FB
8595057622791
FB
8595057623019
KN-OD45 100
FB
8595057622739
KN-OB90 100
FB
8595057622807
KN-Z 125
FB
8595057623026
KN-OD45 125
FB
8595057622746
8595057623101
KN-Z 160
FB
8595057623033
KN-OD45 160
FB
8595057622753
8595057623118
KN-Z 200
FB
8595057623040
KN-OD45 200
FB
8595057622760
mm
All accessories for drainage pipes KOPODREN available upon order.
material color
accessories
29
3
ČSN steel threaded pipes
- high mechanical resistance
steel
-60 - +250°C
1250 N/5 cm
44561
The pipes are suitable for mechanical protection of conductors and cables. Threaded conduits are supplied with one coupler. While using pipes along with bushing 4813/P - 4842/P and 4913 - 4942 is scope of application only -5 - +60 °C. Unvarnished: without surface finish, without corrosion resistance, suitable mostly for construction purposes. Varnished: Sendzimir galvanized steel finished with powder technology, colour black RAL 9005, medium corrosion resistance – group 2 ZNM: both side hot-galvanized steel bar, zinc layer 15 - 27 µm, replaces shop primer, medium corrosion resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 µm, high corrosion resistance - group 4 The conduits are also available for fire resistance system.
item
conf.
description
dn
di
L
mm
mm
m
m
EAN pg.
varnished 6013
EOZ
20,4
18,2
P13,5
3
30; 1200
8595057618657
6016
EOZ
22,5
20,3
P16
3
30; 1200
8595057618664
6021
EOZ
28,3
25,7
P21
3
30; 750
8595057618671
6029
EOZ
37
34,4
P29
3
15; 450
8595057618688
6036
EOZ
47
44
P36
3
15; 300
8595057618695
6042
EOZ
54
51
P42
3
15; 225
8595057618701
Sendzimir galvanized steel circumferentially painted black using powder technology
3-30 3-31 3-33 3-38
unvarnished
W I R I N G
6013 N
XX
20,4
18,2
P13,5
3
1350
8595057607491
6016 N
XX
22,5
20,3
P16
3
1200
8595057607507
6021 N
XX
28,3
25,7
P21
3
750
8595057607514
6029 N
XX
37
34,4
P29
3
600
8595057607521
6036 N
XX
47
44
P36
3
300
8595057607538
6042 N
XX
54
51
P42
3
300
8595057607545
uncoated
ZN
P I P E S
6013 ZN
F
20,4
18,2
P13,5
3
30; 1200
8595057618718
6016 ZN
F
22,5
20,3
P16
3
30; 1200
8595057618725
6021 ZN
F
28,3
25,7
P21
3
30; 750
8595057618732
6029 ZN
F
37
34,4
P29
3
15; 450
8595057618749
6036 ZN
F
47
44
P36
3
15; 300
8595057618756
6042 ZN
F
54
51
P42
3
15; 225
8595057618763
hot-dip galvanized
3-30 3-31 3-33 3-38
ZNM 6013 ZNM
S
20,4
18,2
P13,5
3
30; 1200
8595057627208
6016 ZNM
S
22,5
20,3
P16
3
30; 1200
8595057626157
6021 ZNM
S
28,3
25,7
P21
3
30; 750
8595057626164
6029 ZNM
S
37
34,4
P29
3
15; 450
8595057626171
6036 ZNM
S
47
44
P36
3
15; 300
8595057626188
6042 ZNM
S
54
51
P42
3
15; 225
8595057626195
Sendzimir galvanized
Connectors for steel threaded ČSN pipes
Al
The connectors are designed to join steel pipes and elbows for mechanical protection of cables or wires.
item
conf.
EAN mm
30
3-30 3-31 3-33 3-38
pcs
313/1
XX
24 x 30
P13,5
10; 540
8595057604865
316/1
XX
26,5 x 35
P16
10; 350
8595057604872
321/1
XX
32 x 40
P21
10; 240
8595057604889
329/1
XX
41,5 x 45
P29
10; 120
8595057604896
336/1
XX
51,5 x 55
P36
10; 60
8595057604902
342/1
XX
58,5 x 60
P42
10; 100
8595057604919
material
mechanical resistance
functionality during a fire
height, width
temperature resistance
classification
thread
package
accessories
3-30 3-31 3-33 3-38
3
Extending connectors for ČSN steel pipes
Al
Connectors are designed to join flexible metal pipes, 33 series (pg. 3-41) with steel threaded pipes. On one side is the inner PG thread, on the other side is the locking notch for fixing the flexible metal pipe.
item
pipe dn
conf. mm
mm
EAN pcs
9813
XX
24 x 30
18,9
P13,5
10; 540
8595057605060
9816
XX
26,5 x 35
21,4
P16
10; 350
8595057605077
9829
XX
32 x 40
35,2
P29
10; 240
8595057605091
Elbows for ČSN steel threaded pipes
steel
- high mechanical resistance
-60 - +250°C
1250 N/5 cm
44561
Elbows are fitted with a connector on one side. Varnished: Sendzimir galvanized steel finished with powder technology, colour black RAL 9005, medium corrosion resistance – group 2 ZNM: both side hot-galvanized steel bar, zinc layer 15 - 27 µm, replaces shop primer, medium corrosion resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 µm, high corrosion resistance - group 4 The elbows are also available for fire resistance system. item
conf.
description
dn
R
mm
mm
pcs
EAN
varnished 6113
EOZ
20,4
P13,5
80
1; 25
8595057618893
6116
EOZ
22,5
P16
100
1; 25
8595057618909
6121
EOZ
28,3
P21
120
1; 20
8595057618916
6129
EOZ
37
P29
155
1; 20
8595057618923
6136
EOZ
47
P36
185
1; 5
8595057618930
6142
EOZ
54
P42
200
1; 5
8595057618947
Sendzimir galvanized steel circumferentially painted black using powder technology
ZN 6113 ZN
F
20,4
P13,5
80
1; 25
8595057618954
6116 ZN
F
22,5
P16
100
1; 25
8595057618961
6121 ZN
F
6129 ZN
F
6136 ZN 6142 ZN
28,3
P21
120
1; 20
8595057618978
37
P29
155
1; 20
8595057618985
F
47
P36
185
1; 5
8595057618992
F
54
P42
200
1; 5
8595057619005
hot-dip galvanized
W I R I N G P I P E S
ZNM 6113 ZNM
S
20,4
P13,5
80
1; 25
8595057627277
6116 ZNM
S
22,5
P16
100
1; 25
8595057627284
6121 ZNM
S
6129 ZNM
S
6136 ZNM 6142 ZNM
28,3
P21
120
1; 20
8595057627291
37
P29
155
1; 20
8595057627307
S
47
P36
185
1; 5
8595057627314
S
54
P42
200
1; 5
8595057627321
Sendzimir galvanized
material
mechanical resistance
functionality during a fire
height, width
temperature resistance
classification
thread
package
31
3
ČSN steel unthreaded pipes
- high mechanical resistance
steel
-60 - +250°C
1250 N/5 cm
44561
The pipes are suitable for mechanical protection of conductors and cables. While using pipes along with bushing 4813/P - 4842/P and 4913 - 4942 is scope of application only -5 - +60 °C. Unvarnished: without surface finish, without corrosion resistance, suitable mostly for construction purposes. ZNM: both side hot-galvanized steel bar, zinc layer 15 - 27 µm, replaces shop primer, medium corrosion resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 µm, high corrosion resistance - group 4 item
conf.
description
dn
di
L
mm
mm
m
m
EAN pg.
unvarnished 6216 N
XX
22,5
20,3
3
1200
6221 N
XX
28,3
25,7
3
750
8595057607613
6229 N
XX
37
34,4
3
600
8595057607644
6236 N
XX
47
44
3
300
8595057607675
6242 N
XX
54
51
3
300
8595057607705
uncoated
8595057607583 3-32 3-33 3-38
ZN F
20,4
18,2
3
30; 1200
8595057698390
6216 ZN
F
22,5
20,3
3
30; 1200
8595057698406
6221 ZN
F
28,3
25,7
3
30; 750
8595057698413
6229 ZN
F
37
34,4
3
15; 450
8595057698420
6236 ZN
F
47
44
3
15; 300
8595057698437
6242 ZN
F
54
51
3
15; 225
8595057698444
hot-dip galvanized
6213 ZNM
S
20,4
18,2
3
1350
8595057607576
6216 ZNM
S
22,5
20,3
3
1200
8595057607606
6221 ZNM
S
28,3
25,7
3
750
8595057607637
6229 ZNM
S
37
34,4
3
600
8595057607668
6236 ZNM
S
47
44
3
300
8595057607699
6242 ZNM
S
54
51
3
300
8595057607729
Sendzimir galvanized
Slide-on connectors for ČSN steel pipes
steel
The connectors are designed to join steel pipes for mechanical protection of cables or wires. Both ends are fitted with sockets. The connectors are manufactured from strip steel by welding.
item
32
3-32 3-33 3-38
ZNM
W I R I N G P I P E S
6213 ZN
conf.
di
pipe dn
L
mm
mm
mm
EAN pcs
313/2
XX
20,9
20,4
10
8595057620094
316/2
XX
23,1
22,5
10
8595057620100
321/2
XX
28,8
28,3
329/2
XX
37,5
37,0
336/2
XX
47,5
342/2
XX
54,6
10
8595057620117
10
8595057620124
47,0
10
8595057620131
54,0
10
8595057620148
material
mechanical resistance
package
temperature resistance
classification
accessories
65
3-32 3-33 3-38
3
Double-sided clamps for ČSN steel pipes
steel
The clamps are designed to attach ČSN steel pipes to the pad.
item
D
L
a
t
d
mm
mm
mm
mm
mm
10
0,8
4,3
conf.
5213 PC
S
20,4
44,5
5216 PC
S
22,5
45,5
5221 PC
S
28,3
5229 PC
S
5236 PC 5242 PC
EAN pcs
100; 1300
8595057605008
100; 1100
8595057605015
55,3
100; 800
8595057605022
37
67,0
50; 350
8595057605039
S
47
83,0
50; 200
8595057605046
S
54
95,0
50; 150
8595057605053
15
1,1
5,3
W I R I N G OMEGA clamps for ČSN steel pipes
steel
The clamps are designed to attach ČSN steel pipes to the pad. The clamps are also available for systems maintaining functionality during a fire (see catalogue Systems maintaining functionality during a fire).
item
conf.
description
pipe dn
d
di
mm
mm
mm
P I P E S
EAN pcs
ZN 5220 ZN
F
20,4; 22,5
19 - 24
1; 50
8595568915276
5225 ZN
F
28,3
24 - 29
1; 50
8595568915283
5232 ZN
F
5250 ZN
F
5263 ZN
F
hot-dip galvanized
37
29 - 38
1; 25
8595568915290
47
38 - 47
1; 20
8595568915306
54
47 - 55
1; 50
8595568915313
6,4
ZNM
material functionality during a fire
5220 ZNM
S
20,4; 22,5
19 - 23
1; 100
8595057692091
5225 ZNM
S
28,3
24 - 28
1; 100
8595057692107
5232 ZNM
S
30 - 40
1; 100
8595057692114
5250 ZNM
S
47
39 - 52
1; 50
8595057692138
5263 ZNM
S
54
53 - 63
1; 50
8595057692145
Sendzimir galvanized
37
6,4
package
33
3
EN steel threaded pipes - very high mechanical resistance
steel
-45 - +250°C
4000 N/5 cm
55561
The pipes are suitable for mechanical protection of conductors and cables. Threaded conduits are supplied with one coupler. While using pipes along with bushing 4816E - 4863 is scope of application only -5 - +60 °C. Painted ECZ: smooth steel material coated on both sides with black, medium corrosion resistance - group 2 Varnished EOZ: Sendzimir galvanized steel finished with powder technology, colour black RAL 9005, medium corrosion resistance – group 2 ZNM: both side hot-galvanized steel bar, zinc layer 15 - 27 µm, replaces shop primer, medium corrosion resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 µm, high corrosion resistance - group 4 The conduits are also available for fire resistance system.
item
conf.
dn
di
L
mm
mm
m
m
description
EAN pg.
varnished 6016E
ECZ
16
12,2
M16x1,5
3
30; 600
8595057634152
6020
EOZ painted in black circumferentially
20
15,8
M20x1,5
3
30; 600
8595568919595
6025
ECZ
25
20,6
M25x1,5
3
30; 600
8595057634176
6025
EOZ painted in black circumferentially
25
20,6
M25x1,5
3
30; 600
8595568920379
6032
ECZ
32
26,6
M32x1,5
3
21; 420
8595057634183
6040
ECZ
40
34,4
M40x1,5
3
15; 150
8595057634190
6050
ECZ
50
43,8
M50x1,5
3
15; 150
8595057634206
6063
ECZ
63
58,8
M63x1,5
3
15; 150
8595057634213 8595057631304
painted in black on both sides
painted in black on both sides
painted in black on both sides
3-34 3-35 3-37 3-38
ZN
W I R I N G P I P E S
6016E ZN
F
16
12,2
M16x1,5
3
30; 600
6020 ZN
F
20
15,8
M20x1,5
3
30; 600
8595057631311
6025 ZN
F
25
20,6
M25x1,5
3
30; 600
8595057631328
6032 ZN
F
32
26,6
M32x1,5
3
21; 420
8595057631335
6040 ZN
F
40
34,4
M40x1,5
3
15; 150
8595057631342
6050 ZN
F
50
43,8
M50x1,5
3
15; 150
8595057631359
6063 ZN
F
63
58,8
M63x1,5
3
15; 150
8595057631595
hot-dip galvanized
ZNM 6020 ZNM
S
6025 ZNM
S
Sendzimir galvanized
20
15,8
M20x1,5
3
30; 600
8595568919601
25
20,6
M25x1,5
3
30; 600
8595568920393
Connectors for steel threaded EN pipes
steel
The connectors are designed to join steel pipes and elbows for mechanical protection of cables or wires.
item
conf.
description
EAN pcs
varnished 316E/1
ECZ
M16x1,5
1; 25
8595057634640
320/1
ECZ
M20x1,5
1; 50
8595057634657
325/1
ECZ
M25x1,5
1; 50
8595057634664
332/1
ECZ
M32x1,5
1; 50
8595057634671
340/1
ECZ
M40x1,5
1; 25
8595057634688
350/1
ECZ
M50x1,5
1; 10
8595057634695
363/1
ECZ
M63x1,5
1; 5
8595057634701
painted in black on both sides
ZN-Ni
34
3-34 3-35 3-37 3-38
316E/1 ZN
F
M16x1,5
1; 25
8595057634572
320/1 ZN
F
M20x1,5
1; 50
8595057634589
325/1 ZN
F
M25x1,5
1; 50
8595057634596
332/1 ZN
F
M32x1,5
1; 50
8595057634602
340/1 ZN
F
M40x1,5
1; 25
8595057634619
350/1 ZN
F
M50x1,5
1; 10
8595057634626
363/1 ZN
F
M63x1,5
1; 5
8595057634633
hot-dip galvanized
material
mechanical resistance
functionality during a fire
package
temperature resistance
classification
thread
accessories
3-34 3-35 3-37 3-38
Elbows for EN steel threaded pipes
steel
3
- very high mechanical resistance
-45 - +250°C
4000 N/5 cm
55561
Elbows are fitted with a connector on one side. Varnished: smooth steel material to be varnished by both sides black colour, medium corrosive resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 Âľm, high corrosion resistance - group 4 The elbows are also available for fire resistance system.
item
conf.
description
dn
R
mm
mm
pcs
EAN
varnished 6116E
ECZ
16
M16x1,5
55
1; 15
6120
ECZ
20
M20x1,5
70
1; 25
8595057634374
6125
ECZ
25
M25x1,5
115
1; 25
8595057634381
6132
ECZ
32
M32x1,5
125
1; 20
8595057634398
6140
ECZ
40
M40x1,5
140
1; 15
8595057634404
6150
ECZ
50
M50x1,5
170
1; 5
8595057634411
6163
ECZ
63
M63x1,5
210
1; 3
8595057634428
6116E ZN
F
16
M16x1,5
55
1; 15
8595057631366
6120 ZN
F
20
M20x1,5
70
1; 25
8595057631373
6125 ZN
F
25
M25x1,5
115
1; 25
8595057631380
6132 ZN
F
32
M32x1,5
125
1; 20
8595057631397
6140 ZN
F
40
M40x1,5
140
1; 15
8595057631403
6150 ZN
F
50
M50x1,5
170
1; 5
8595057631410
6163 ZN
F
63
M63x1,5
210
1; 3
8595057631670
steel material painted black on both sides
8595057634367
ZN
hot-dip galvanized
W I R I N G
Double-sided clamps for EN steel pipes
P I P E S
steel
For attaching EN steel pipes to the pad.
item
conf.
description
D
L
a
t
d
mm
mm
mm
mm
mm
EAN pcs
varnished 5220 PC
ECZ
20
45
5225 PC
ECZ
25
50
32
57
40
70 85
5232 PC
ECZ
5240 PC
ECZ
5250 PC
ECZ
50
5263 PC
ECZ
63
painted in black on both sides
10
0,8 5,3
12
1,1
96
1; 100
8595057631618
1; 100
8595057631625
1; 100
8595057631632
1; 50
8595057631649
1; 50
8595057631656
1; 50
8595057631663
ZN 5220 PC ZN
F
20
45
5225 PC ZN
F
25
50
5232 PC ZN
F
32
57
5240 PC ZN
F
40
70
5250 PC ZN
F
50
85
5263 PC ZN
F
63
96
hot-dip galvanized
material
mechanical resistance
functionality during a fire
temperature resistance
classification
thread
10
0,8 5,3
12
1,1
1; 100
8595057634794
1; 100
8595057634800
1; 100
8595057634817
1; 50
8595057634824
1; 50
8595057634831
1; 50
8595057634848
package
35
3
EN steel unthreaded pipes
- high mechanical resistance
steel
-45 - +250°C
1250 N/5 cm
44561
The pipes are suitable for mechanical protection of conductors and cables. While using pipes along with bushing 4816E - 4863 is scope of application only -5 - +60 °C. Painted ECZ: smooth steel material coated on both sides with black, medium corrosion resistance - group 2 Varnished EOZ: Sendzimir galvanized steel finished with powder technology, colour black RAL 9005, medium corrosion resistance – group 2 ZNM: both side hot-galvanized steel bar, zinc layer 15 - 27 µm, replaces shop primer, medium corrosion resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 µm, high corrosion resistance - group 4 The conduits are also available for fire resistance system.
item
conf.
description
dn
di
L
mm
mm
m
EAN m
pg.
varnished 6216E
ECZ
painted in black on both sides
16
12,2
3
30; 600
8595057634299
6220
EOZ
painted in black circumferentially
20
15,8
3
30; 600
8595568919618
6225
ECZ
painted in black on both sides
25
20,6
3
30; 600
8595057634312
6225
EOZ
painted in black circumferentially
25
20,6
3
30; 600
8595568920386
6232
ECZ
32
26,6
3
21; 420
8595057634329
6240
ECZ
40
34,4
3
15; 150
8595057634336
6250
ECZ
50
43,8
3
15; 150
8595057634343
6263
ECZ
63
58,8
3
15; 150
8595057634350
painted in black on both sides
3-32 3-36 3-38
ZN
W I R I N G P I P E S
6216E ZN
F
16
12,2
3
30; 600
8595057634220
6220 ZN
F
20
15,8
3
30; 600
8595057634237
6225 ZN
F
25
20,6
3
30; 600
8595057634244
6232 ZN
F
32
20,6
3
21; 420
8595057634251
6240 ZN
F
40
26,6
3
15; 150
8595057634268
6250 ZN
F
50
34,4
3
15; 150
8595057634275
6263 ZN
F
63
43,8
3
15; 150
8595057634282
20
15,8
3
30; 600
8595568919625
25
20,6
3
30; 600
8595568920409
hot-dip galvanized
ZNM 6220 ZNM
S
6225 ZNM
S
Sendzimir galvanized
Slide-on connectors for EN steel pipes
steel
The connectors are designed to join steel pipes and elbows for mechanical protection of cables or wires. Both ends are fitted with sockets. The connectors are manufactured from strip steel by welding.
item
conf.
di
description
EAN
mm
pcs
varnished 316E/2
ECZ
16
1; 25
8595057631427
320/2
ECZ
20
1; 50
8595057631434
325/2
ECZ
25
1; 50
8595057631441
332/2
ECZ
32
1; 50
8595057631458
340/2
ECZ
40
1; 25
8595057631465
350/2
ECZ
50
1; 10
8595057631472
363/2
ECZ
63
1; 5
8595057631588
painted in black on both sides
ZN-Ni
36
3-32 3-36 3-38
316E/2 ZN
F
16
1; 25
8595057634718
320/2 ZN
F
20
1; 50
8595057634725
325/2 ZN
F
25
1; 50
8595057634732
332/2 ZN
F
32
1; 50
8595057634749
340/2 ZN
F
40
1; 25
8595057634756
350/2 ZN
F
50
1; 10
8595057634763
363/2 ZN
F
63
1; 5
8595057634770
zinc - nickel coating
material
mechanical resistance
package
temperature resistance
classification
accessories
3-32 3-36 3-38
Elbows for EN steel threadless pipes
steel
3
- high mechanical resistance
-45 - +250°C
1250 N/5 cm
44561
Both ends are fitted with sockets. Varnished: smooth steel material to be varnished by both sides black colour, medium corrosive resistance - group 2 ZN: after steel bar welding hot-galvanized using immersion, zinc layer 50 - 100 Âľm, high corrosion resistance - group 4
item
conf.
di
R
mm
mm
pcs
description
EAN
varnished 6316E
ECZ
16
55
1; 15
6320
ECZ
20
70
1; 25
8595057634510
6325
ECZ
25
115
1; 25
8595057634527
6332
ECZ
32
125
1; 20
8595057634534
6340
ECZ
40
140
1; 15
8595057634541
6350
ECZ
50
170
1; 5
8595057634558
6363
ECZ
63
210
1; 3
8595057634565 8595057634435
steel material painted black on both sides
8595057634503
ZN 6316E ZN
F
16
55
1; 15
6320 ZN
F
20
70
1; 25
8595057634442
6325 ZN
F
25
115
1; 25
8595057634459
6332 ZN
F
32
125
1; 20
8595057634466
6340 ZN
F
40
140
1; 15
8595057634473
6350 ZN
F
50
170
1; 5
8595057634480
6363 ZN
F
63
210
1; 3
8595057634497
hot-dip galvanized
W I R I N G
OMEGA clamps for EN steel pipes
steel
The clamps are designed to attach EN steel pipes to the pad. The clamps are also available for systems maintaining functionality during a fire (see catalogue Systems maintaining functionality during a fire).
item
conf.
pipe dn
d
di
mm
mm
mm
P I P E S
EAN pcs
ZN 5216E ZN
F
16
15 - 19
1; 50
8595568915269
5220 ZN
F
20
19 - 24
1; 50
8595568915276
5225 ZN
F
25
24 - 29
1; 50
8595568915283
5232 ZN
F
32
29 - 38
1; 25
8595568915290
5240 ZN
F
40
38 - 47
1; 25
8595568915306
5250 ZN
F
50
47 - 55
1; 20
8595568915313
5263 ZN
F
63
55 - 63
1; 20
8595568915320
6,4
ZNM 5216E ZNM
S
16
15 - 18
1; 100
8595057692084
5220 ZNM
S
20
19 - 23
1; 100
8595057692091
5225 ZNM
S
25
24 - 28
1; 100
8595057692107
5232 ZNM
S
32; 40
30 - 40
1; 100
8595057692114
5250 ZNM
S
50
39 - 52
1; 50
8595057692138
5263 ZNM
S
63
53 - 63
1; 50
8595057692145
6,4
material
mechanical resistance
functionality during a fire
temperature resistance
classification
package
37
3
Straight gland for EN steel pipes - external
PE
-5 - +60°C
30 sec.
The bushings are designed to mechanically protect the conductors or cables coming from the steel pipe. Plug the bushing from outside on the end of pipe before installing cables.
item
conf.
pipe dn
di
mm
mm
pcs
EAN
4816E
KA
16
12
100; 3000
8595057688575
4820
KA
20
16
100; 1200
8595057688582
4825
KA
25
21
100; 800
8595057688599
4832
KA
32
28
50; 400
8595057688605
4840
KA
40
35
50; 200
8595057688612
4850
KA
50
43
25; 100
8595057688629
4863
KA
63
57
10; 70
8595057688636
Straight gland for ČSN pipes - external
W I R I N G
PE
-5 - +60°C
30 sec.
The bushings are designed to mechanically protect the conductors or cables coming from the steel pipe. Plug the bushing from outside on the end of pipe before installing cables.
item
P I P E S
conf.
pipe dn
di
mm
mm
pcs
EAN
4813/P
KB
20,4
15
100; 3000
8595057604926
4816/P
KB
22,5
16
100; 1200
8595057604933
4821/P
KB
28,3
22
100; 1000
8595057604940
4829/P
KB
37
30
100; 400
8595057604971
4836/P
KB
47
37
100; 300
8595057604988
4842/P
KB
54
42
75; 150
8595057604995
Straight gland for ČSN steel pipes - internal
PE
-5 - +60°C
30 sec.
The bushings are designed to mechanically protect the conductors or cables coming from the the steel pipe. Plug the bushing from inside on the end of pipe before installing cables.
item
38
conf.
pipe dn
di
mm
mm
pcs
EAN
4913
KB
13
18,2
400; 2800
8595057657236
4916
KB
16
20,3
400; 2000
8595057657243
4921
KB
21
25,7
250; 1500
8595057657250
4929
KB
30
34,4
100; 700
8595057657267
4936
KB
39
44
80; 400
8595057657274
4942
KB
46
51
60; 360
8595057657281
material
self-snuffing
temperature resistance
package
Aluminium seamless pipes
3
- high mechanical resistance
Al
-45 - +250°C
1250 N/5 cm
44561
The pipes are proper for mechanical protection of conductors and cables. They can be used for industrial installations, high anticorrosive ability – class 4.
item
conf.
dn
di
L
mm
mm
m
m
EAN pg.
6216E AL
XX
16
14
3
30; 1800
8595057657731
6220 AL
XX
20
18
3
30; 1200
8595057657748
6225 AL
XX
25
23
3
30; 750
8595057657755
6232 AL
XX
32
30
3
30; 480
8595057657762
6240 AL
XX
40
38
3
15; 300
8595057657779
6250 AL
XX
50
47
3
15; 180
8595057657786
6263 AL
XX
63
59,8
3
15; 120
8595057657793
3-38 3-39 3-40
Slip-on couplers for aluminium pipes
Al
The connectors are designed to join aluminium pipes for mechanical protection of cables or wires. Both ends are fitted with sockets.
item
conf.
di
EAN
mm
pcs
316E/2 AL
XX
16
1; 50
8595057657878
320/2 AL
XX
20
1; 50
8595057657885
325/2 AL
XX
25
1; 50
8595057657892
332/2 AL
XX
32
1; 50
8595057657908
340/2 AL
XX
40
1; 20
8595057657915
350/2 AL
XX
50
1; 20
8595057657922
363/2 AL
XX
63
1; 25
8595057657939
Elbows for aluminium pipes
W I R I N G P I P E S
- high mechanical resistance
Al
-45 - +250°C
1250 N/5 cm
44561
Both ends are fitted with sockets.
item
conf.
di
R
mm
mm
pcs
EAN
6316E AL
XX
16
55
1; 25
6320 AL
XX
20
70
1; 25
8595057657816
6325 AL
XX
25
115
1; 25
8595057657823
6332 AL
XX
32
125
1; 20
8595057657830
6340 AL
XX
40
140
1; 15
8595057657847
6350 AL
XX
50
170
1; 5
8595057657854
6363 AL
XX
63
210
1; 3
8595057657861
material
mechanical resistance
package
temperature resistance
classification
accessories
8595057657809
39
3
Aluminium clamps OMEGA
Al
For attaching aluminium pipes to the pad. To facilitate mounting, the clamp is provided with a groove for insertion; during mounting, it is not required to completely separate the top part of the clamp.
item
conf.
pipe dn
d
mm
mm
EAN pcs
5216E AL
XX
16
1; 50
8595057689725
5220 AL
XX
20
1; 50
8595057689732
5225 AL
XX
25
1; 50
8595057689749
5232 AL
XX
32
1; 25
8595057689756
5240 AL
XX
40
1; 25
8595057689763
5250 AL
XX
50
1; 25
8595057689770
5263 AL
XX
63
1; 20
8595057689787
6,4
Aluminium clamps
W I R I N G
Al
For attaching aluminium pipes to the pad. Pipes are installed by pushing between the clamp jaws.
item
P I P E S
conf.
pipe dn
d
mm
mm
EAN pcs
5216E PC AL
XX
16
1; 50
8595057688650
5220 PC AL
XX
20
1; 50
8595057688667
5225 PC AL
XX
25
1; 50
8595057688674
5232 PC AL
XX
32
1; 50
8595057688681
5240 PC AL
XX
40
1; 25
8595057688698
5250 PC AL
XX
50
1; 25
8595057688704
5263 PC AL
XX
63
1; 5
8595057688711
6,4
Corrosion protection for galvanized surfaces Corrosion protection for repair of defective and damaged places on galvanized surfaces. The colour is applied with a brush, stippling technique.
item
conf.
description
EAN pcs
material
40
package
GZS
XX
WEICON 375
XX
WEICON 750
XX
spray color
1
8595057633148
1
8595057621183
1
8595057693609
3
Flexible metal pipe
steel
-45 - +90°C
750 N/5 cm
33522
The pipes are suitable for mechanical protection of conductors and cables inside halls (indoor). The pipes are made of galvanized steel bar at the top (zinc layer 3 - 4 Âľm) and isolation layer inside. Flexible metal pipes may be connected to steel threaded pipes by means of couplings of 98xx series.
item
3313 3316 3323 3329 3336 3348
conf. B XX B XX B XX B XX B XX B XX
dn
di
L
mm
mm
m
18,9
13,5
21,4
16
28,9
23
35,2 43 54,9
EAN pg.
10
8595057655850
100
8595057604230
10
8595057655867
100
8595057604247
10
8595057655874
50
8595057604254
10
8595057655881
50
8595057604261
10
8595057655898
25
8595057604278
10
8595057655904
25
8595057604292
29 36 48
3-31 3-41
W I R I N G
Couplers for flexible metal pipes
Al
The couplers are designed to join flexible metal pipes using inner clipping nick. While stocks last.
item
conf.
dn trubky
EAN
mm
mm
pcs
9613
XX
18,9
24 x 35
10; 540
8595057604568
9616
XX
21,4
26,5 x 40
10; 350
8595057604575
P I P E S
Double-sided clamps
steel
The clamps are designed to attach flexible metal pipes to the pad.
item
conf.
D
L
a
t
d
mm
mm
mm
mm
mm
10
0,8
4,3
3613 A
S
18,5
40,5
3616 A
S
20,9
46,9
3623 A
S
28,3
3629 A
S
3636 A 3648 A
EAN pcs
100; 1300
8595057604629
100; 1100
8595057604636
55,3
100; 800
8595057604643
34,5
67,5
50; 350
8595057604650
S
42,2
82,2
50; 200
8595057604667
S
54,0
95,0
50; 150
8595057604674
material
mechanical resistance
height, width
temperature resistance
classification
package
15
1,1
5,3
accessories
41
3
Wiring pipes - number of cables to put in
cable diameter (mm)
6
CYKY 2 x 1,5
CYKY 3 x 1,5
CYKY 4 x 1,5
8,3
8,7
9,5
CYKY 3 x 2,5
CYKY 5 x 1,5
CYKY 4 x 2,5
CYKY 5 x 2,5
CYKY 4x4
CYKY 5x4
CYKY 4x6
CYKY 5x6
10
10,3
10,9
12,3
13,2
14,4
14,4
16
FLEXIBLE PIPES XX16E - EN
W I R I N G P I P E S
1
1
1
X
X
X
X
X
X
X
X
X
XX20 - EN
2 (3)
1
1
1
1
1
1
X
X
X
X
X
XX25 - EN
4
2
2
1
1
1
1
1
1
1
1
X
XX32 - EN
8
4
4
3
3
3
2
1
1
1
1
1
XX40 - EN
13
7
6
5
5
4
4
3
3
2
2
1
XX50 - EN
21
11
10
8
7
7
6
5
4
4
4
3
XX13 - ČSN
2
1
1
1
1
1
1
X
X
X
X
X
XX16 - ČSN
3
1 (2)
1
1
1
1
1
1
1
X
X
X
XX23 - ČSN
7
4
3
3
2
2
1 (2)
1
1
1
1
1
XX29 - ČSN
11
6
5
4
4
4
3
3
2
1
1
1
XX36 - ČSN
17
9
8
7
6
6
5
4
3
3
3
2
SF16
3
1
1
1
1
1
1
1
1
X
X
X
SF20
5
3
2
1 (2)
1
1
1
1
1
1
1
1
SF25
8
4
4
3
3
3
2 (3)
1 (2)
1
1
1
1
SF32
13
7
6
5
5
5
4
3
3
2 (3)
2 (3)
1 (2)
KF 09040
13
7
6
5
5
5
4
3
3
2
2
2
KF 09050
22
11
10
9
8
7
7
5
5
4
4
3
KF 09063
35
18
17
14
13
12
11
8
7
6
6
5
KF 09075
49
25
23
19
18
17
15
12
10
8
8
7
KF 09090
74
38
35
29
27
25
22
18
15
13
13
10
KF 09110
116
60
55
46
42
39
35
28
24
20
20
16
KF 09120
131
68
62
52
47
44
40
31
27
23
23
18
KF 09125
153
80
73
61
55
52
46
36
32
27
27
21
KF 09160
242
127
115
97
87
82
73
58
50
42
42
34
KF 09175
295
154
140
117
106
100
89
70
61
51
51
41
RIGID PIPES XX16E - EN
1 (2)
1
1
1
1
1
X
X
X
X
X
X
XX20 - EN
2 (3)
1
1
1
1
1
1
1
1
X
X
X
XX25 - EN
6
3
3
2
1 (2)
1 (2)
1
1
1
1
1
1
XX32 - EN
9
5
4
4
3
3
23
2
1
1
1
1
XX40 - EN
15
8
7
6
6
5
5
4
3
3
3
1 (2)
XX50 - EN
24
13
12
10
9
8
7
6
5
4
4
3
XX63 - EN
43
22
20
17
15
14
13
10
9
7
7
6
6013 - ČSN
4
2
1 (2)
1
1
1
1
1
1
1
1
X
6016 - ČSN
2 (3)
3
3
1 (2)
1
1
1
1
1
1
1
1
6021 - ČSN
9
5
4
3
3
3
3
1 (2)
1
1
1
1
6029 - ČSN
15
8
7
6
6
5
5
4
3
3
3
2
6036 - ČSN
25
13
12
10
9
9
8
6
5
4
4
4
6042 - ČSN
34
18
16
14
12
12
10
8
7
6
6
5
6016E - EN
3
1
1
1
1
1
1
1
X
X
X
X
6020 - EN
4
2
1 (2)
1
1
1
1
1
1
1
1
X
6025 - EN
7
3
3
3
2
2
1
1
1
1
1
1
6032 - EN
11
6
5
5
4
4
3
3
2
1
1
1
6040 - EN
19
10
9
7
7
6
6
4
4
3
3
3
6050 - EN
30
15
14
12
11
10
9
7
6
5
5
4
6063 - EN
48
25
23
19
17
16
15
11
10
8
8
7
KD 09040
13
7
6
5
5
5
4
3
3
2
2
2
KD 09050
22
11
10
9
8
7
7
5
5
4
4
3
KD 09063
35
18
17
14
13
12
11
8
7
6
6
5
KD 09075
49
25
23
19
18
17
15
12
10
8
8
7
KD 09090
74
38
35
29
27
25
22
18
15
13
13
10
KD 09110
116
60
55
46
42
39
35
28
24
20
20
16
KD 09120
131
68
62
52
47
44
40
31
27
23
23
18
KD 09125
153
80
73
61
55
52
46
36
32
27
27
21
KD 09160
242
127
115
97
87
82
73
58
50
42
42
34
KD 09175
295
154
140
117
106
100
89
70
61
51
51
41
KD 09200
401
209
191
160
144
136
121
95
83
70
70
56
The table is based on 60% cross-section usage of the pipes.
42
3
W I R I N G P I P E S
43
FIXING M AT E R I A L
4
Fixing material Dowels ......................................................................................................................................................................................................................................................... 4-3 Clamps ........................................................................................................................................................................................................................................................ 4-5 Cable hanger ............................................................................................................................................................................................................................................... 4-6 Tightening belts .......................................................................................................................................................................................................................................... 4-8 Tightening belt clamps .............................................................................................................................................................................................................................. 4-9
F I X I N G M A T E R I A L
All clamps, cable hangers and tightening belts are in compliance with EU directives.
Icons – capture material
dimensions - height, width (mm)
package (pcs)
drilling depth (mm)
color
diameter screw (mm)
halogen-free material
minimum wrap diameter (mm)
temperature resistance
maximum wrap diameter (mm)
functionality during a fire
opening force (N)
outside diameter (mm)
2
Axial tension capacity for KOPOS KOLÍN a.s. dowels in particular construction materials Axial tension capacity (N) concrete 20/25
brick
soft material
gas-silicate
HM 6
560
420
230
100
HM 8/1
700
690
500
120
HM 10
1200
750
580
300
HM 12
2150
1250
850
390
HL 6
300
150
120
HL 8
300
120
400
HL 10
300
130
450
plaster
HS 6
HM
150
- dowels
PA
-30- +80°C
item
conf.
D
L
mm
mm
mm
mm
pcs
EAN
HM 6
XX
6
30
35
∅ 3,5 - 4
100; 14000
8595057605213
HM 8/1
XX
8
40
45
∅4-5
100; 6000
8595057605251
HM 10
XX
10
50
55
∅5-6
100; 3000
8595057605176
HM 12
XX
12
60
65
∅6-8
100; 2000
8595057605190
For fixed mounting of wiring and other elements on walls and ceilings made of hard materials (concrete, bricks, etc.). For connection, use a screw fitted to full length of the wall plug; it is also necessary to allow for the thickness of material to be fastened.
For more information, see installation instructions.
Recommendation: wall plugs should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the wall plug quality.
HM PE
4
- dowels
PE
F I X I N G M A T E R I A L
-30- +70°C
item
conf.
D
L
mm
mm
mm
mm
pcs
EAN
HM 6 PE
XX
6
30
35
∅ 3,5 - 4
200; 14000
8595057632622
HM 8 PE
XX
8
40
45
∅4-5
200; 6000
8595057632639
HM 10 PE
XX
10
50
55
∅5-6
200; 3000
8595057632646
HM 12 PE
XX
12
60
65
∅6-8
200; 2000
8595057632653
For universal use (hobby). For connection, use a screw fitted to full length of the wall plug; it is also necessary to allow for the thickness of material to be fastened.
For more information, see installation instructions.
material
halogen-free material
diameter screw
temperature resistance
drilling depth
package
3
4
HL
- dowels
PE
-30- +70°C
item
conf.
D
L
mm
mm
mm
mm
pcs
EAN
HL 6
XX
6
34
40
∅ 3,5 - 4
100; 10000
8595057612280
HL 8
XX
8
48
55
∅4-5
100; 4000
8595057605329
HL 10
XX
10
59
65
∅5-6
100; 2400
8595057612273
For fixed mounting of wiring and other elements into hollow walls and ceilings.
For connection, use a screw fitted to full length of the wall plug; it is also necessary to allow for the thickness of material to be fastened.
HS
For more information, see installation instructions.
- dowels
F I X I N G
PA
-30- +80°C
item
conf.
HS 6
M A T E R I A L
ZA
EAN mm
pcs
∅ 3,5 - 4,5
100; 6000
8595057608795
For fixed mounting of wiring and other elements on the walls and ceilings of drywall materials. The package includes two drills HSV 6. Simple insertion into drill HSV 6.
Recommendation: wall plugs should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the wall plug quality.
HSV 6
- drill
PA
-30- +80°C
item
conf.
EAN pcs
HSV 6
4
ZA
10; 250
8595057609051
Multiple use.
material
halogen-free material
diameter screw
temperature resistance
drilling depth
package
HN
4
- hammering dowels
PA
-30- +80°C
item
conf.
dn
L
mm
mm
mm
pcs
EAN
HN 6X25
XX
6
25
25
200; 4800
8595057618473
HN 6X35
XX
6
35
35
100; 2400
8595057618480
HN 6X45
XX
6
5
45
100; 2400
8595057618497
HN 6X55
XX
6
55
55
100; 2000
8595057618503
HN 6X70
XX
6
70
70
70; 1200
8595057618510
HN 8X45
XX
8
45
45
100; 1200
8595057618527
To fix non-structural elements and various objects into the masonry of solid bricks and concrete. When installing, the screw-nail is not screwed , but rather pounded in; if necessary, it can be unscrewed. For more information, see installation instructions.
Recommendation: wall plugs should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the wall plug quality.
F I X I N G Spacing clamps
PS
-5 - +60°C
item
conf.
EAN conductor - mm
pcs
6516
HA
8 - 16
500
8595057605411
6526
HA
13 - 26
150
8595057605442
M A T E R I A L
The clamps consist of two parts and are designed to fix individual cables. The installation is done by screwing or gluing the bottom of the clamp to the pad, inserting the cable and pushing the top part to the bottom part.
material
halogen-free material
drilling depth
temperature resistance
outside diameter
package
5
4
Lineal clamps
PA
-30- +80°C
item 6723
conf.
FA
EAN conductor max. - mm
pcs
10 - 26
1000; 4000
8595057606227
To fix the protected conductors with ∅10-26 mm side by side on the support trunking 5820 or 5822.
Installation is done by bending the clips into a U-shape and inserting into the support trunking. Is secured against displacement with a wedge, which is pre-moulded on the clip.
Recommendation: clamps should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the clamp quality.
Lineal clamps
F I X I N G
PA
-30- +70°C
item
conf.
EAN pcs
6724
M A T E R I A L
LA
200; 1600
8595057606241
The clamps are designed to fix cables or other lines with ∅ 7-13 mm. Installation is done by sliding into the support trunking 5820 or 5822 and turning 90°.
Recommendation: clamps should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the clamp quality.
Cable hanger
PE
-40- +85°C
item
conf.
EAN pcs
6401
6
FA
1000; 4000
8595057605473
Intended for fixing cables with ∅ 8-18 mm on a supporting rope. Installation is only suitable for indoor use.
material
halogen-free material
temperature resistance
outside diameter
package
4
Double-sided clamps
steel
item
conf.
D
L
a
t
d
mm
mm
mm
mm
mm
EAN pcs
6808
S
8
32
100; 3000
8595057605572
6810
S
10
32
100; 3000
8595057605589
6812
S
12,5
39
100; 1800
8595057605596
6816
S
16
48
100; 1500
8595057605602
6820
S
20
56
100
8595057605619
6825
S
25
61
100; 500
8595057605626
10
15
0,8
1,1
4,3
5,3
To fix cables with ∅ 8-25 mm on the pad.
F I X I N G Single-sided clamps
steel
item
functionality during a fire
D
L
a
t
d
mm
mm
mm
mm
mm
EAN pcs
6704
S
4
15
100; 5000
8595057605527
6706
S
6
18
100; 5000
8595057605534
6708
S
8
20
100; 5000
8595057605541
6710
S
10
23
100; 5000
8595057605558
6712
S
12,5
25,5
100; 5000
8595057605565
material
conf.
10
0,8
4,3
M A T E R I A L
To fix cables with ∅ 4-12.5mm on the pad. Details on clamps functional during a fire can be found in the orange catalogue Systems with maintained functionality in fire.
package
7
4
Tightening belts
PA
-40 - +85°C -10 - +30°C montage
item
F I X I N G M A T E R I A L
L
W
mm
mm
mm
mm
N
pcs
conf.
EAN
SP 100X2.5
FA
black
100
2,5
3
20
80
100
SP 100X2.5
HA
natural
100
2,5
3
20
80
100
8595568905239 8595057621190
SP 140X3.5
HA
natural
150
3,6
3
33
180
100
8595057621206
SP 140X3.5
FA
black
150
3,6
3
33
180
100
8595568902764
SP 140X4.5
HA
natural
140
4,5
4
36
280
100
8595057629196
SP 160X2.5
HA
natural
165
2,5
4
39
80
100
8595057629189
SP 160X4.5
HA
natural
160
4,8
5
35
220
100
8595057629202
SP 180X4.5
FA
black
190
4,8
4
45
220
100
8595568902771
SP 180X4.5
HA
natural
190
4,8
4
45
220
100
8595057629219
SP 200X4.5
FA
black
190
4,8
4
45
220
100
8595568905215
SP 200X4.5
HA
natural
190
4,8
4
45
220
100
8595057621213
SP 250X4.5
HA
natural
250
4,8
5
62
220
100
8595057629226
SP 280X4.5
FA
black
310
4,8
7
79
220
100
8595568902788
SP 280X4.5
HA
natural
310
4,8
7
79
220
100
8595057621220
SP 360X4.5
FA
black
368
4,8
7
96
220
100
8595568902894
SP 360X4.5
HA
natural
368
4,8
7
96
220
100
8595057621237
SP 360X7.5
FA
black
380
7,6
8
96
550
100
8595057634084
SP 360X7.5
HA
natural
380
7,6
8
96
550
100
8595057621244
SP 380X4.5
FA
black
368
4,8
7
96
220
100
8595568902795
SP 380X4.5
HA
natural
368
4,8
7
96
220
100
8595057629233
SP 430X4.5
FA
black
450
4,8
8
129
220
100
8595568902801
SP 430X4.5
HA
natural
450
4,8
8
129
220
100
8595057629240
For normal bundling and fixing of cables, wires and pipes. For fixing to a pad, use cable tie clamps (str. 4-9). Fire resistance according to U.L. 94 - V2. Not long-term resistant to sunlight.
Recommendation: cable ties should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the cable tie quality.
Tightening belts with identification tag
PA
-40 - +85°C -10 - +30°C montage
item SPM 100X2.5
conf.
HA
natural
L
a
mm
mm
mm
mm
N
pcs
100
2,5
5
25
80
100
EAN
8595057621398
For easy and rapid marking or labelling of ties or cables. For fixing to a pad, use cable tie clamps (str. 4-9). Fire resistance according to U.L. 94 - V2. Not long-term resistant to sunlight.
Recommendation: cable ties should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the cable tie quality.
8
material
halogen-free material
wrap diameter
temperature resistance
color
opening force
package
4
Clip for cable ties - self-adhesive
PA
-30- +40°C
item
conf.
EAN mm
pcs
SPP 19X19
FA
black
19 x 19
100
8595057629257
SPP 19X19
HA
natural
19 x 19
100
8595057689947
To fix the tie on the pad. Fire resistance according to U.L. 94 - V2. Not long-term resistant to sunlight. Self-adhesive.
Recommendation: clamps should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the clamp quality.
Clip for cable ties
PA
-40- +85°C
item
conf.
SPPN 19X19
EAN
FA
black
mm
pcs
19 x 19
100
8595057631694
To fix the tie on the pad. Fire resistance according to U.L. 94 - V2. Not long-term resistant to sunlight. Fixing to pad using a screw.
Recommendation: clamps should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the clamp quality.
Clip for cable ties
PA
F I X I N G M A T E R I A L
-40- +85°C
item
conf.
EAN pcs
SPP 9
HA
natural
100
8595057629172
To fix the tie on the pad. Fire resistance according to U.L. 94 - V2. Not long-term resistant to sunlight. Fixing to pad using a screw.
Recommendation: clamps should be installed immediately after unpacking from the sealed bag. This will prevent unnecessary reduction in the level of humidity PA, which would result in a reduction in the clamp quality.
material
halogen-free material
width, height
temperature resistance
color
package
9
TECHNICAL I N F O R M AT I O N
5
Fire-technical characteristics tests record Fire-technical lab as an accredited test shop no. 1007.7 reported these records for below-stated materials: Testing method for determination of total heating value (PCS): ÄŒSN EN ISO 1716 Measured values
Report no.
T E C H N I C A L I N F O R M A T I O N
2
Material
1st measurement 2nd measurement 3rd measurement
Results
Extended uncertainty
12274
PVC stabilized by Pb
17,584
17,540
17,594
17,57
0,07
12275
PVC stabilized by CaZn
18,125
18,104
18,182
18,14
0,09
12276
PE - liten
46,377
46,432
46,414
46,41
0,07
12277
PE - box bodies 8130, 8135, steel pipes bushings
44,889
44,867
44,866
44,87
0,03
12278
PP - concrete program
27,546
27,508
27,606
27,55
0,12
12279
PP - box covers 8130, 8135
41,685
41,696
41,689
41,69
0,02
12280
PPO/PPE
35,086
35,120
35,150
35,12
0,08
Construction material classification by flammability
5
ČSN 33 2312, addition Z1 provides a conversion method from flammability classes requirements to fire reaction classes for construction products except for floor covering. Fire reaction class (according to ČSN EN 13501-1)
Flammability class (according to formerly used ČSN 73 0862)
A1
A
A2
B
B
C1
C or D
C2
E or F
C3
Classification of construction products according to their fire class For the classification of construction products according to their fire class, the following tested procedure is used: Class E A product to be classified as class E, shall be tested in accordance with ČSN EN ISO 11925-2 using flame applied for a period of 15 s. Classes D, C, B A product to be classified in classes D, C or B, shall be tested according to ČSN EN ISO 11925-2 using flame applied for a period of 30 s. The product meeting the requirements for test results according to ČSN EN ISO 11925-2, is further tested according to ČSN EN 13823 or ČSN EN ISO 9239-1 - this applies to floor coverings. Classes A1, A2 Homogeneous products Product classified as class A1 shall be tested according to ČSN EN ISO 1182 and ČSN EN ISO 1716. Product classified as class A2 shall be tested in accordance with either ČSN EN ISO 1182 or ČSN EN ISO 1716. Non-homogeneous products Any substantial component of non-homogeneous product classified as class A1 shall be tested separately according to ČSN EN ISO 1182 and ČSN EN ISO 1716. In addition, each product containing external non-substantial component and meeting the PCS criterion is tested according to ČSN EN 13823 or ČSN EN ISO 9239-1 – this applies to floor coverings. Any substantial component of non-homogeneous product classified as class A2 shall be tested either separately according to ČSN EN ISO 1182 or ČSN EN ISO 1716. Non-substantial components of non-homogeneous products are tested separately, and only in accordance with ČSN EN ISO 1716. Another condition for class A2 All products to be classified as class A2 shall be also tested according to ČSN EN 13823 or ČSN EN ISO 9239-1 for floor coverings.
Until 31 December 2007 individual building materials were evaluated and graded according to ČSN 73 0862 "Determination of flammability of construction materials". This standard was discontinued as of 31 December 2003, but in order to ensure continuity in the evaluation of materials within the design standards, the results of the tests under this standard as well as the Value standard ČSN 73 0823 remained valid until 31 December 2007. According to this standard, construction materials were classified under the above classes. With effect from 1 July 2003 a new way of flammability classification became valid in the Czech Republic, known as "reaction to fire", summarized in the classification standard ČSN EN 13501-1. ČSN 33 2312:85 "Electrical regulations. Electrical equipment in and on flammable substances" allowed the use of conversion table to use both designations in relation to the flammability of construction materials. As of 1 October 2007 the provision of this standard was repealed for boxes in relation to the standard ČSN EN 60 670-1, i.e. the validity of ČSN 33 2312:85 was terminated for wiring boxes, but continues to apply to wiring trunkings, channels and pipes. The applicability of the standard ČSN 37 0100 "Wiring boxes" was terminated as of 1 October 2007. It has been replaced by ČSN EN 60 670-1 "Boxes and enclosures for electrical accessories for household and similar fixed electrical installations."
T E C H N I C A L I N F O R M A T I O N
3
5
Protection types - IP classification Protection levels against contact with dangerous parts are indicated by the complementary code in the form of a letter. The letter added after the second digit of the IP designation indicates the protection level of persons against contact with dangerous parts, e.g. IP 10B. These letters are used only in the following cases: * if the actual protection against contact with dangerous parts is higher than that indicated by the first characteristic digit * if only protection against contact with dangerous parts is specified, the first characteristic digit is then replaced by an X This higher protection level can be ensured by barriers, spacings inside the housing or suitable shape of the openings.
Protection
Foreign objects
International
Water
fist
vertical
finger
slightly inclined
heavy
inclined
light
spattering
Hand
Tool
A - Protected against contact with the back of the hand B - Protected against contact with fingers C - Protected against contact with tools D - Protected against contact with wires
partially
spurting
Dust
Rain
Water
intensively spurting
totally
temporary Example of marking used
T E C H N I C A L I N F O R M A T I O N
Chemical resistance of wiring trunkings, conduits and accessories made of hard PVC, PE, PA, PS, PP and PPE Key: # : These materials are resistant to chemical damage under normal installation conditions o : The resistance of these materials to chemical damage is limited x : These materials are not resistant to chemical damage under specified conditions Abbreviations: PVC - polyvinylchloride, PE - polyethylene, PA - polyamide, PS - polystyrene, PP - polypropylene, PPE (PPO) - polyphenylenether (polyphenyl oxid)
Chemicals
conc. in %
째C
PVC
PE
20
X
#
20
#
#
Anilin
60
O
X
Benzene
20
X
Destilled water
20
#
Aceton Amoniak
25
PA
PS
PP
PPE (PPO)
#
X
#
X
X
O
#
X
O
X
X
O
O
#
X
O
X
#
#
#
#
#
Ethanol
50
20
#
#
#
O
#
#
Phenol solution
5
50
O
O
X
X
X
X
Sodium hydroxide
60
50
#
#
#
#
#
#
X
X
#
X
X
X
Chlorinated hydrocarbons Hydrofluoric acid
40
20
#
#
X
X
#
O
Hydrochloric acid
36
20
O
O
X
O
O
O
Chromic acid
20
O
O
X
O
O
O
Acetic acid
5
20
#
#
X
#
#
O
Sulfuric acid
96
20
#
#
X
#
#
O
Sulfuric acid
30
20
#
#
X
#
#
O
Medicinal oil
#
#
#
#
#
X
Methanol
#
#
#
X
#
#
Olive oil
#
#
#
#
#
X
Petroleum
#
#
#
#
#
X
#
#
O
O
#
O
X
X
X
X
X
X
#
#
#
#
#
X
#
#
#
#
#
#
Hydrogen peroxide
20
20
Tetrachlorocarbon Transformer oil Sodium carbonate
20
PPE (PPO) - in contact with fat, grease and oil the material degradation occurs (it becomes fragile and is cracking).
4
Submersion permanent
Classification of wiring pipes according to ČSN EN 61 386-1 ed.2 and IEC 61 386-1 ed.2 The digit code classifies the conduits and their accessories according to compressive strength, impact strength, minimum and maximum admissible installation temperature. first digit compressive strength
Pipes:
second digit
third digit
fourth digit
fifth digit
impact strength
lowest admissible temperature
highest admissible temperature
resistance to bending
1
very low 125 N
1
very low 0,5 J
1
+ 5 °C
1
+ 60 °C
1
lead
2
low 320 N
2
low 1 J
2
- 5 °C
2
+ 90 °C
2
flexible
3
medium 750 N
3
medium 2 J
3
- 15 °C
3
+105 °C
3
flexible/elastic
4
high 1250 N
4
high 6 J
4
- 25 °C
4
+120 °C
4
flexible
5
very high 4000 N
5
very high 20,4 J
5
- 45 °C
5
+150 °C
6
+250 °C
7
+400 °C
KOPOS type 1516E - 1563 KOPOS type 4016E - 4063 KOPOS type 8016E - 8063
EN 2241 (320 N) EN 3341 (750 N) EN 4441 (1250 N)
5
PVC PVC PVC
It is possible to protect the steel against corrosion by the following methods of surface treatments
ZNCR electrolytic galvanized products – Bichromatic galvanized – ČSN EN ISO 2081, DIN 12 330 electrolytic galvanized according to DIN 50 961 with a layer of zinc 10 µm +/- 4 µm (supports for the wall, fastening material, bolts, washers, nuts …)
S
Pre-Galvanized – ČSN EN 10 327, ČSN EN 10 143 galvanized steel Sendzimir: while cold the hot-rolled steelbelt goes after preparation through a continuous bath with liquid zinc. Through this, a layer zinc arises which guarantees the increased corrosion protection.
F
Hot Dip Galvanized – ČSN EN ISO 1461 The finished pieces made from bare (black) sheet metal are plunged in a melt-bath with liquid zinc, after pre-treatment, at a temperature of 450°C. After removal from the zinc bath a zinc/iron alloy layer system is formed on the bare (black) sheet metal, which is covered with a pure zinc layer. The thickness of the zinc-layer is 50 - 100 µm, depending on the material thickness.
GMT
non electrolytic plating The base of the DELTA surfacing includes Delta Tone 9000 materials. They are inorganic coats filled with zinc and aluminium micro-lamellas spread in a titanium binder. The method creates a cathodic protection coating the layer of which is 5-15 micrometer thick. This thickness of the layer provides better protection of metals than a thicker layer of zinc created by the zinc dipping method. The method conforms to the European Directive on recycling since it does not include any heavy metals and hexavalent chromium and it is also suitable for small parts. KOPOS KOLÍN supplies also bolts, nuts, couplings and other small connecting accessories with this surfacing and the company also carried out the salt fog test in accordance with ČSN EN ISO 9227 which proved that the coating was not damaged during the action of the salt fog for the period of 300 hours. The long-term temperature constancy is guaranteed up to 180 °C while the surfacing does not show any hydrogen fragility. Based on the above stated reasons we may fully recommend this method of surfacing as an alternative to the zinc dipping method.
ZN-Ni zinc-nickel coat – DIN 50962
T E C H N I C A L I N F O R M A T I O N
The thickness of coat is 8-18 microns. The products were tested by independent test institute. The test was done according to ISO 7253:2002-04:1982 in salt chamber, according to DIN 50017 in climatic chamber. After all test reanalyzes, the zinc-nickel process coating was elected as the one of most effective. Also comparing to hot dip galvanizing. Even the surface is thinner, requested anticorrosive protection is done.
5
5
Basic terms and concepts Flame-spread resistance (Self-snuffing ability): Flame-spread resistant products cannot flash or if they flash, they cannot further burn, when a source of flame is removed. The test is performed with exactly specified source of flame. Tested sample passed the test, if: - it didn’t flash - in case of fire, the flame or smouldering of the sample extinguishes within 30 s after the removal of the test flame and there will be no ignition of the silk paper nor the board underneath the test sample
Excess heat and combustion resistance: Parts of isolation material that could be subject of heat stress caused by electrical effects and that could break safety are not allowed to be affected too much by excessive heat and combustion. The test is performed using flaming loop. Tested sample passed the flaming loop test, if: - no flame or lasting glow is visible - flames and glow on tested sample expire within 30 s after the flaming loop is removed - the silk paper didn’t flash and the board under tested sample isn’t chard
Heat resistance: Isolation material parts necessary for fixing power current parts and/or protective circuit parts in their position are subject of steel ball compression test. Tested sample passed the test, if the impress diameter caused by the ball doesn’t exceed given size under given temperature.
T E C H N I C A L I N F O R M A T I O N
The meaning of marks used with the products of KOPOS KOLÍN a.s.
Trade mark of KOPOS KOLÍN a.s.
Product designed for installation in hollow walls (850 °C in compliance with ČSN 34 5615).
The approval mark of EZÚ PRAHA – indicates compliance with Czech electrical standard.
Product designed for installation in concrete (650 °C in compliance with ČSN 34 5615).
The approval mark of EVPÚ a.s. NOVÁ DUBNICA – indicates compliance with Slovak electrical standard.
Compliance mark with Russian quality certification system.
Compliance mark with EU directions for particular product.
Compliance mark with Russian fire-safety certification system.
The approval mark of VDE – test and certification institute in Offenbach. Indicates compliance with German electrical standard.
Mark of conformity with a Belorussian system of technical standards.
Test temperature of flaming loop in compliance with ČSN 34 5615-84.
Mark of conformity with a Ukrainian system in a field of fire safety.
Product material labeling in compliance with ČSN 77 0052.
6
5
Returnable packages
IP1 - pipe pallet
IP10 - metal pallet
IP2 - metal box
dimension: 120 x 80 x 63 cm
dimension: 180 x 120 x 82 cm
dimension: 120 x 80 x 60 cm
EAN: 8595057687660
EAN: 8595057688230
EAN: 8595057687653
IP3-1 - wooden pallet EUR
IP3-3 - wooden pallet
PR - container 357-515
dimension: 120 x 80 cm
dimension: 160 x 240 cm
dimension: 60 x 40 x 40 cm
EAN: 8595057687684
EAN: 8595057687677
EAN: 8595057687745
BM - small box
BS - medium box
BV - large box
dimension: 52 x 30 x 30 cm
dimension: 80 x 60 x 60 cm
dimension: 120 x 80 x 60 cm
EAN: 8595057688209
EAN: 8595057688216
EAN: 8595057688223
M6500 - drum M220
I N F O R M A T I O N
IP4 - wooden base
dimension: 225 x 116 cm
dimension: 250 x 65 cm
EAN: 8595057687769
EAN: 8595057687707
M6502 - steel drum
T E C H N I C A L
IP5 - wooden base
dimension: 230 x 116 cm
dimension: 300 x 65 cm
EAN: 8595568910639
EAN: 8595057687714
IP7 - wooden base dimension: 200 x 65 cm EAN: 8595057687738
7
5
T E C H N I C A L I N F O R M A T I O N
Alphabetical list of products Type code
page
003.CS.K 005.CS.K 02040 02050 02063 02075 02090 02110 02120 02125 0216 0216/1 02160 0216E 0216EHF 02175 0220 02200 0220HF 0223 0223/1 0225 0225HF 0229 0229/1 0232 0232HF 0240 0240HF 0250 0250HF 0263 0263HF 05024 05025 05030 05031 05032 05033 05040 05041 05042 05050 05051 05053 06025 06032 06040 06050 06110/2 06160/2 07050/8 07063/8 07075/8 07090/8 07110/8 07125/8 07160/8 07200/8 1216E 1216EHFPP 1220 1220HFPP 1225 1225HFPP 1232 1232HFPP 1240 1240HFPP 1250 1250HFPP 1413/1 1416/1 1416E 1416EHFPP
1-48 1-48 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-6 3-10 3-24 3-16 3-20 3-24 3-20 3-6 3-10 3-16 3-20 3-6 3-10 3-16 3-20 3-16 3-20 3-16 3-20 3-16 3-20 3-16 3-20 3-28 3-27 3-27 3-28 3-28 3-28 3-27 3-28 3-28 3-27 3-28 3-28 3-26 3-26 2-26 3-27 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-6 3-7 3-6 3-7 3-6 3-7 3-6 3-7 3-6 3-7 3-6 3-7 3-5 3-5 3-5 3-7
Type code 1420 1420HFPP 1423/1 1425 1425HFPP 1429/1 1432 1432HFPP 1436/1 1440 1440HFPP 1450 1450HFPP 1516E 1516EHF 1520 1520HF 1525 1525HF 1532 1532HF 1540 1540HF 1550 1550HF 1563 1563HF 1601 16040 16050 16063 16075 16090 1611 16110 1618 17040 17050 17063 17075 17090 17110 17120 17125 17160 17175 17200 2.9X13V 2.9X13Z 2.9X16 2.9X22 2313 2313/LPE-2 2316 2316/LPE-1 2316/LPE-2 2316E 2316E/LPE-1 2316E/LPE-2 2320 2320/LPE-1 2320/LPE-1 UV 2320/LPE-2 2320/LPE-2 UV 2323 2323/LPE-1 2323/LPE-2 2325 2325/LPE-1 2325/LPE-1 UV 2325/LPE-2 2325/LPE-2 UV 2329 2329/LPE-1 2329/LPE-2
page 3-5 3-7 3-5 3-5 3-7 3-5 3-5 3-7 3-5 3-5 3-7 3-5 3-7 3-14 3-18 3-14 3-18 3-14 3-18 3-14 3-18 3-14 3-18 3-14 3-18 3-14 3-18 1-51 3-24 3-24 3-24 3-24 3-24 1-51 3-24 1-51 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 3-24 1-67 1-67 1-67 1-67 3-4 3-11 3-4 3-10 3-11 3-4 3-10 3-11 3-4 3-10 3-12 3-11 3-12 3-4 3-10 3-11 3-4 3-10 3-12 3-11 3-12 3-4 3-10 3-11
* Index of covers for wiring trunkings can be found on page 2-50 and 2-51 in Chapter 2 - Wiring trunkings .
8
Type code 2332 2332/LPE-1 2332/LPE-1 UV 2332/LPE-2 2332/LPE-2 UV 2336 2336/LPE-2 2340 2340/LPE-1 2340/LPE-2 2350 3.0X16 313/1 313/2 316/1 316/2 316E/1 316E/1 ZN 316E/2 316E/2 AL 316E/2 ZN 320/1 320/1 ZN 320/2 320/2 AL 320/2 ZN 321/1 321/2 325/1 325/1 ZN 325/2 325/2 AL 325/2 ZN 329/1 329/2 3313 3316 332/1 332/1 ZN 332/2 332/2 AL 332/2 ZN 3323 3329 3336 3348 336/1 336/2 340/1 340/1 ZN 340/1 340/2 AL 340/2 ZN 342/1 342/2 350/1 350/1 ZN 350/2 350/2 AL 350/2 ZN 3613 A 3616 A 3623 A 3629 A 363/1 363/1 ZN 363/2 363/2 AL 363/2 ZN 3636 A 3648 A 4016E 4016EHF 4020 4020HF
page 3-4 3-10 3-12 3-11 3-12 3-4 3-11 3-4 3-10 3-11 3-4 1-67 3-30 3-32 3-30 3-32 3-34 3-34 3-36 3-39 3-36 3-34 3-34 3-36 3-39 3-36 3-30 3-32 3-34 3-34 3-36 3-39 3-36 3-30 3-32 3-41 3-41 3-34 3-34 3-36 3-39 3-36 3-41 3-41 3-41 3-41 3-30 3-32 3-34 3-34 3-36 3-39 3-36 3-30 3-32 3-34 3-34 3-36 3-39 3-36 3-41 3-41 3-41 3-41 3-34 3-34 3-36 3-39 3-36 3-41 3-41 3-15 3-18 3-15 3-18
Alphabetical list of products Type code 4025 4025HF 4032 4032HF 4040 4040HF 4050 4050HF 4063 4063HF 4116 4116HF 4120 4120HF 4125 4125HF 4132 4132HF 4140 4140HF 4150 4150HF 4813/P 4816/P 4816E 4820 4821/P 4825 4829/P 4832 4836/P 4840 4842/P 4850 4863 4913 4916 4921 4929 4836 4942 5213 PC 5216 PC 5216E AL 5216E PC AL 5216E ZNM 5220 AL 5220 PC 5220 PC AL 5220 PC ZN 5220 ZNM 5221 PC 5225 AL 5225 PC 5225 PC AL 5225 PC ZN 5225 ZNM 5229 PC 5232 AL 5232 PC 5332 PC AL 5323 PC ZN 5232 ZNM 5236 PC 5240 AL 5240 PC 5240 PC AL 5240 PC ZN 5242 PC 5250 AL 5250 PC 5250 PC AL 5250 PC ZN 5250 ZNM 5263 AL
page
Type code
page
Type code
page
3-15 3-18 3-15 3-18 3-15 3-18 3-15 3-18 3-15 3-18 3-16 3-19 3-16 3-19 3-16 3-19 3-16 3-19 3-16 3-19 3-16 3-19 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-38 3-33 3-33 3-40 3-40 3-37 3-40 3-35 3-40 3-35 3-33 3-33 3-40 3-35 3-40 3-35 3-33 3-33 3-40 3-35 3-40 3-35 3-33 3-33 3-40 3-35 3-40 3-35 3-33 3-40 3-35 3-40 3-35 3-33 3-40
5263 PC 5263 PC AL 5263 PC ZN 5263 ZNM 5313 5316 5316E 5316EHF 5320 5320HF 5321 5325 5325HF 5329 5332 5332HF 5340 5340HF 5350 5350HF 5363 5363HF 5820/20 5820/21 5820/30 5820/31 5820/40 5820/41 5822 DER 6013 6013 N 6013 ZN 6013 ZNM 6016 N 6016 ZN 6016 ZNM 6016E 6016E ZN 6020 6020 ZN 6020 ZNM 6021 6021 N 6021 ZN 6021 ZNM 6025 6025 ZN 6029 6029 N 6029 ZN 6029 ZNM 6032 6032 ZN 6036 6036 N 6036 ZN 6036 ZNM 6040 6040 ZN 6042 6042 N 6042 ZN 6042 ZNM 6050 6050 ZN 6063 6063 ZN 6113 6113 ZN 6113 ZNM 6116 ZN 6116 ZNM 6116E 6116E ZN 6120
3-35 3-40 3-35 3-33 3-6 3-6 3-17 3-20 3-17 3-20 3-6 3-17 3-20 3-6 3-17 3-20 3-17 3-20 3-17 3-20 3-17 3-20 2-46 2-46 2-46 2-46 2-46 2-46 2-46 3-30 3-30 3-30 3-30 3-30 3-30 3-30 3-34 3-34 3-34 3-34 3-34 3-30 3-30 3-30 3-30 3-34 3-34 3-30 3-30 3-30 3-30 3-34 3-34 3-30 3-30 3-30 3-30 3-34 3-34 3-30 3-30 3-30 3-30 3-34 3-34 3-34 3-34 3-31 3-31 3-31 3-31 3-31 3-35 3-35 3-35
6120 ZN 6121 6121 ZN 6121 ZNM 6125 6125 ZN 6129 6129 ZN 6129 ZNM 6132 6132 ZN 6136 6136 ZN 6136 ZNM 6140 6140 ZN 6142 6142 ZN 6142 ZNM 6150 6150 ZN 6163 ZN 6213 ZN 6213 ZNM 6216 N 6216 ZN 6216 ZNM 6216E 6216E AL 6216E ZN 6220 6220 AL 6220 ZN 6220 ZNM 6221 N 6221 ZN 6221 ZNM 6225 6225 AL 6225 ZN 6229 N 6229 ZN 6229 ZNM 6232 6232 AL 6232 ZN 6236 N 6236 ZN 6236 ZNM 6240 6240 AL 6240 ZN 6242 N 6242 ZN 6242 ZNM 6250 6250 AL 6250 ZN 6263 6263 AL 6263 ZN 6303-11 6303-12 6316E 6316E AL 6316E ZN 6320 6320 AL 6320 ZN 6325 6325 AL 6325 ZN 6332 6332 AL 6332 ZN
3-35 3-31 3-31 3-31 3-35 3-35 3-31 3-31 3-31 3-35 3-35 3-31 3-31 3-31 3-35 3-35 3-31 3-31 3-31 3-35 3-35 3-35 3-32 3-32 3-32 3-32 3-32 3-36 3-39 3-36 3-36 3-39 3-36 3-36 3-32 3-32 3-32 3-36 3-39 3-36 3-32 3-32 3-32 3-36 3-39 3-36 3-32 3-32 3-32 3-36 3-39 3-36 3-32 3-32 3-32 3-36 3-39 3-36 3-36 3-39 3-36 1-69 1-69 3-37 3-39 3-37 3-37 3-39 3-37 3-37 3-39 3-37 3-37 3-39 3-37
5
T E C H N I C A L I N F O R M A T I O N
* Index of covers for wiring trunkings can be found on page 2-50 and 2-51 in Chapter 2 - Wiring trunkings .
9
5
T E C H N I C A L I N F O R M A T I O N
Alphabetical list of products Type code 6340 6340 AL 6340 ZN 6350 6350 AL 6350 ZN 6363 6363 AL 6363 ZN 6401 6516 6526 6704 6706 6708 6710 6712 6723 6724 6808 6810 6812 6816 6820 6825 7116 B 7116 C 7121 B 7121 C 7216 B 7216 C 7221 B 7221 C 8016E 8016EHF 8020 8020HF 8025 8025HF 8032 8032HF 8040 8040HF 8050 8050HF 8063 8063HF 8101 8102 8106 8107 8110 8111 8112 8117 8118 8119 8130 8135 8420-11 8420-12 8440-11 8440-12 8440-13 8450-11 8450-12 8450-13 8550-11 8550-12 8550-13 8560-11 8560-12 8560-13 9613 9616
page 3-37 3-39 3-37 3-37 3-39 3-37 3-37 3-39 3-37 4-6 4-5 4-5 4-7 4-7 4-7 4-7 4-7 4-6 4-6 4-7 4-7 4-7 4-7 4-7 4-7 1-49 1-49 1-50 1-50 1-49 1-49 1-50 1-50 3-15 3-19 3-15 3-19 3-15 3-19 3-15 3-19 3-15 3-19 3-15 3-19 3-15 3-19 1-42 1-42 1-43 1-43 1-44 1-44 1-45 1-45 1-46 1-46 1-47 1-47 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 2-44 3-41 3-41
Type code 9813 9816 9829 A16FL A16FL-45 A16FL-90 A16RT A21FL A21FL-45 A21FL-90 A21RT A28FL A28FL-45 A28FL-90 A28RT A34RT A42RT A54RT A80FL-90 A-ES16 A-ES20 A-ES28 A-ES32 A-ES40 A-LN/PG13 A-LN/PG16 A-LN/PG21 A-LN/PG29 A-LN/PG36 A-LN/PG48 AM16/16 AM16/16-45 AM16/16-90 AM20/20 AM21/20 AM21/20-45 AM21/20-90 AM25/25 AM28/25 AM28/25-45 AM28/25-90 AM34/32 AM34/32-45 AM34/32-90 AM42/40 AM42/40-45 AM42/40-90 AM54 AM54/50-45 AM54/50-90 APACS42 APACS54 APACS80 APAFS16 APAFS21 APAFS28 APAFS34 APG16/13 APG16/13-45 APG16/13-90 APG21/16 APG21/16-45 APG21/16-90 APG28/21 APG28/21-45 APG28/21-90 APG34/29 APG34/29-45 APG34/29-90 APG42/36 APG42/36-45 APG42/36-90 APG54/48 APG54/48-45 APG54/48-90
page 3-31 3-31 3-31 3-8 3-8 3-8 3-9 3-8 3-8 3-8 3-9 3-8 3-8 3-8 3-9 3-9 3-9 3-9 3-8 3-8 3-8 3-8 3-8 3-8 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9
* Index of covers for wiring trunkings can be found on page 2-50 and 2-51 in Chapter 2 - Wiring trunkings .
10
Type code A-SW/M16 A-SW/M20 A-SW/M25 A-SW/M32 A-SW/M40 A-SW/M50 A-SW/PG13 A-SW/PG16 A-SW/PG21 A-SW/PG29 A-SW/PG36 A-SW/PG48 BK 16 BK 16 CSN BK 20 BK 23 BK 25 BK 32 BV 1620 BV 2532 DR18 DR42 EKD 100X40 EKD 120X40 EKD 80X40 EKD 80X40HF EKE 100X60 EKE 140X60 EKE 180X60 EKE 60X60 EPS 2 EPS 3 FR 68 SDS G-49 GZS HL 10 HL 6 HL 8 HM 10 HM 10 PE HM 12 HM 12 PE HM 6 HM 6 PE HM 8 PE HM 8/1 HN 6X25 HN 6X35 HN 6X45 HN 6X55 HN 6X70 HN 8X45 HS 6 HSV 6 KBE-1 KBM KBP-1 KBP-1/71 KBP-10 KBP-8 KBP-9 KBS-120 KBS-2 KBS-3 KBT-1 KBT-2 KBT-3/71 KBV-1 KBV-2 KBV-2/71 KBV-3 KD 09040 KD 09050 KD 09063 KD 09075
page 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 3-9 1-92 1-92 1-92 1-92 1-92 1-92 1-92 1-92 1-65 1-65 2-31 2-31 2-30 2-16 2-28 2-28 2-29 2-27 1-70 1-70 1-72 1-51 3-40 4-4 4-4 4-4 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-3 4-5 4-5 4-5 4-5 4-5 4-5 4-4 4-4 1-90 1-91 1-89 1-89 1-91 1-91 1-91 1-90 1-86 1-87 1-85 1-85 1-86 1-87 1-88 1-88 1-88 3-23 3-23 3-23 3-23
Alphabetical list of products Type code KD 09090 KD 09110 KD 09125 KD 09160 KD 09175 KD 09200 KEZ KEZ-3 KF 09040 KF 09040 UV KF 09050 KF 09050 UV KF 09063 KF 09063 UV KF 09075 KF 09075 UV KF 09090 KF 09090 UV KF 09110 KF 09110 UV KF 09120 KF 09125 KF 09160 KF 09160 UV KF 09175 KF 09200 KI 68 L/1 KN-K90 100 KN-K90 125 KN-K90 160 KN-K90 200 KN-K90 80 KN-KK 100 KN-KK 125 KN-KK 160 KN-KK 200 KN-KK 50 KN-KK 65 KN-KK 80 KN-OB90 100 KN-OB90 50 KN-OB90 65 KN-OB90 80 KN-OD45 100 KN-OD45 125 KN-OD45 160 KN-OD45 200 KN-OD45 50 KN-OD45 65 KN-OD45 80 KN-R 100/80 KN-R 125/100 KN-R 160/125 KN-R 200/160 KN-R 65/50 KN-R 80/65 KN-S 100 KN-S 125 KN-S 160 KN-S 200 KN-S 50 KN-S 65 KN-S 80 KN-T 100 KN-T 125 KN-T 160 KN-T 200 KN-T 50 KN-T 65 KN-T 80 KN-Z 100 KN-Z 125 KN-Z 160 KN-Z 200 KN-Z 50
page 3-23 3-23 3-23 3-23 3-23 3-23 1-17 1-17 3-21 3-22 3-21 3-22 3-21 3-22 3-21 3-22 3-21 3-22 3-21 3-22 3-21 3-21 3-21 3-22 3-21 3-21 1-21 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-29
Type code KN-Z 65 KN-Z 80 KO 100 KO 100 E KO 110/L KO 125 KO 125 E KO 125E/EQ02 KO 125 V KO 125/1L KO 68 KO 97 V KO 97 V/1 KO 97/5 KO 97/L KOM 97 KOM 97/LU KOM 97HF KOPOBOX 57 KOPOBOX 80 KOPOBOX mini B KOPOBOX mini L KOPOBOX mini P KOPODREN 100 KOPODREN 125 KOPODREN 160 KOPODREN 200 KOPODREN 50 KOPODREN 65 KOPODREN 80 KOPOKAN 1 KOPOKAN 2 KOPOKAN 3 KOPOKAN 4 KP 64/2 KP 64/2L KP 64/3 KP 64/3L KP 64/4 KP 64/4L KP 64/5 KP 64/5L KP 64/LD KP 64/LD HF KP 67/2 KP 67/3 KP 67X67 KP 68 KP 68/2 KP 68/2HF KP EKE KP PK KPM 64/LU KPP 80 KPR 68 KPR 68/71L KPR 68/L KR 97/5 KR 97/L KSK 100 KSK 125 KSK 175 KSK 80 KT 250 KT 250 V KT 250/1 KT 250/L KT 250X110 KU 68 LA/1HF KU 68 LD/1 KU 68 LD/1HF KU 68 LD/2 KU 68/71L1 KU 68-1901 KU 68-1901HF
page 3-29 3-29 1-12 1-13 1-25 1-13 1-14 1-14 1-61 1-26 1-59 1-59 1-59 1-11 1-24 1-12 1-27 1-54 1-78 1-78 1-74 1-74 1-75 3-29 3-29 3-29 3-29 3-29 3-29 3-29 3-25 3-25 3-25 3-25 1-8 1-22 1-8 1-23 1-9 1-23 1-9 1-24 1-22 1-55 1-5 1-6 1-10 1-7 1-6 1-53 2-42 2-42 1-27 1-88 1-7 1-21 1-20 1-11 1-25 1-39 1-40 1-40 1-39 1-15 1-61 1-15 1-26 1-16 1-54 1-19 1-55 1-20 1-19 1-4 1-53
Type code KU 68-1902 KU 68-1903 KUH 1 KUH 1/L KUP 57 KUP 80 L-42W LE 100 LE 40 LE 60 LE 80 LH 15X10 LH 60X40 LHD 17X17 LHD 20X10 LHD 20X10HF LHD 20X20 LHD 20X20HF LHD 25X15 LHD 25X20 LHD 30X25 LHD 32X15 LHD 40X20 LHD 40X20HF LHD 40X40 LHD 40X40HF LK 80/1 LK 80/2 LK 80/3 LK 80R/1 LK 80R/2 LK 80R/3 LK 80X16 T LK 80X20R/1 LK 80X28 2R LK 80X28 2T LK 80X28 2THF LK 80X28 2ZK LK 80X28 2ZKHF LK 80X28 2ZT LK 80X28 T LK 80X28 2HF LK 80X28/1 LK 80X28R/1 LK 80X28R/1HF LKM 45 LO 35 LO 50 LO 75 LP 35 LP 80X25 LPK 80X25 LR 30 LV 11X10 LV 18X13 LV 24X22 LV 40X15 LZ 15X12 LZK 15X12 M3X40-3CH M3X45-3CH MDZ MKU 64 MKU 97 MP3-3CH NR 2ZT NR 68/10 NR 68/6 NR 80/R NRB 60/12 NRB 60/24 NRT P 110 L P1 P-16
page 1-4 1-5 1-10 1-28 1-79 1-80 2-45 2-26 2-24 2-25 2-25 2-8 2-13 2-9 2-9 2-14 2-10 2-14 2-10 2-11 2-11 2-12 2-12 2-15 2-13 2-15 1-30 1-30 1-31 1-32 1-32 1-33 1-35 1-33 1-35 1-37 1-58 1-34 1-57 1-36 1-36 1-58 1-31 1-34 1-57 1-37 2-22 2-23 2-23 2-20 2-18 2-19 2-21 2-5 2-6 2-6 2-7 2-17 2-17 1-67 1-67 1-18 1-66 1-66 1-67 1-64 1-65 1-65 1-64 1-89 1-89 1-64 1-66 1-71 1-52
5
T E C H N I C A L I N F O R M A T I O N
* Index of covers for wiring trunkings can be found on page 2-50 and 2-51 in Chapter 2 - Wiring trunkings .
11
5
T E C H N I C A L I N F O R M A T I O N
Alphabetical list of products Type code P-21 PEKD 40 PEKD 40HF PEKE 60 PEP 60 PEP 60/K PI 80 2ZK PI 80 2ZT PI 80R PI 80T PK 110X70 D PK 110X70 D HF PK 120X55 D PK 140X70 D PK 160X65 D PK 170X70 D PK 210X70 D PK 90X55 D PKS 70/60 PKUP PLSK PLUK PLUK 1 PN 40X15 PN 40X20 PN 80X25 PN 80X25 2Z PN EKE PN PK PNE 100X20 PNE 20 2Z PNE 60X20 PNE 60X20 2Z PNE 80X20 PNE 80X20 2Z PNLP 35 2Z PP 80/0 PP 80/3 PP 80/45 PP 80/K-5 PSK 1 PUK 38X150 S1 RK 100X100 RK 100X100 SF RK 100X50 HF RK 100X60 RK 100X75 DIN RK 100X75 HF RK 100X80 RK 100X80 SF RK 120X60 RK 120X80 RK 125X75 DIN RK 125X75 HF RK 25X100 RK 25X25 DIN RK 25X30 RK 25X37,5 DIN RK 25X40 RK 25X50 DIN RK 25X75 DIN RK 30X100 RK 30X30 RK 30X40 RK 30X60 RK 30X80 RK 30X80 SF RK 37,5X37,5 DIN RK 37,5X37,5 HF RK 37,5X50 DIN RK 37,5X50 HF RK 37,5X75 DIN RK 37,5X75 HF RK 40X100 RK 40X40
page 1-52 2-38 2-38 2-38 2-39 2-39 1-67 1-67 1-67 1-67 2-32 2-16 2-35 2-33 2-36 2-33 2-37 2-34 2-39 1-82 2-40 1-83 1-83 2-42 2-42 2-43 2-43 2-43 2-43 2-41 2-41 2-41 2-41 2-41 2-41 2-43 1-81 1-81 1-81 1-79 2-40 1-83 2-47 2-47 2-48 2-47 2-48 2-48 2-47 2-47 2-47 2-47 2-48 2-48 2-47 2-48 2-47 2-48 2-47 2-48 2-48 2-47 2-47 2-47 2-47 2-47 2-47 2-48 2-48 2-48 2-48 2-48 2-48 2-47 2-47
Type code RK 40X60 RK 40X60 SF RK 40X80 RK 40X80 SF RK 50X37,5 DIN RK 50X50 DIN RK 50X50 HF RK 50X75 DIN RK 50X75 HF RK 60X100 RK 60X100 SF RK 60X40 RK 60X60 RK 60X60 SF RK 60X80 RK 60X80 SF RK 75X50 DIN RK 75X50 HF RK 75X75 DIN RK 75X75 HF RK 80X100 RK 80X60 RK 80X60 SF RK 80X80 RK 80X80 SF RK-OVK20 RK-OVK30 RK-OVK40 RK-PN3,5 RK-PN5 RK-PN6 RK-ST12 RK-ST22 RK-ST6 S-66 S-96 SF16 SF20 SF25 SF32 SFM20 SFM25 SFM32 SFM40 SK 40X20 SK 40X33 S-KSK 1 S-KSK 2 SN SP 100X2,5 SP 12X1/10 SP 140X3,5 SP 140X4,5 SP 15X1/10 SP 160X2,5 SP 160X4,5 SP 180X4,5 SP 200X4,5 SP 250X4,5 SP 280X4,5 SP 360X4,5 SP 360X7,5 SP 430X4,5 SP-96 SPM 100X2,5 SPOJKA K1 SPOJKA K2 SPOJKA K3 SPOJKA K4 SPP 19X19 SPP 9 SPPN 19X19 SPUK TN 68 TN 97
page 2-47 2-47 2-47 2-47 2-48 2-48 2-48 2-48 2-48 2-47 2-47 2-47 2-47 2-47 2-47 2-47 2-48 2-48 2-48 2-48 2-47 2-47 2-47 2-47 2-47 2-49 2-49 2-49 2-49 2-49 2-49 2-49 2-49 2-49 1-68 1-68 3-13 3-13 3-13 3-13 3-13 3-13 3-13 3-13 2-40 2-40 1-41 1-41 1-82 4-8 2-45 4-8 4-8 2-45 4-8 4-8 4-8 4-8 4-8 4-8 4-8 4-8 4-8 1-68 4-8 3-25 3-25 3-25 3-25 4-9 4-9 4-9 1-83 1-60 1-60
* Index of covers for wiring trunkings can be found on page 2-50 and 2-51 in Chapter 2 - Wiring trunkings .
12
Type code TS35 TS35 D TS35 D ZN TS 35 D ZNCR TS 35 ZN TS 35 ZNCR TYP015 TYP016 TYP017 TYP018 TYP210 TYP310 TYP412 TYP512 TYP612 V 100 E V 110 L V 125/1 V 68 V 68 S V 68HF VB ČSN VB EN VBU 1 VDS 68 VK 20 VKP 64/2L VKT 250/L VLK 80 VLK 80/2R VLK 80/R VLK 80/T VPT 40 VPT 64 VPT 68 VPT 79 VPT 97 VPTU WEICON 375 WEICON 750 ZBU ZPP ZV 68 ZV 97
page 2-46 2-46 2-46 2-46 2-46 2-46 1-70 1-70 1-70 1-70 1-69 1-69 1-69 1-69 1-69 1-61 1-61 1-16 1-60 1-92 1-56 1-93 1-93 1-93 1-72 2-45 1-61 1-61 1-62 1-63 1-63 1-63 1-71 1-71 1-71 1-71 1-71 1-71 3-40 3-40 1-71 1-81 1-62 1-62
5
T E C H N I C A L I N F O R M A T I O N
13
2013-2014
2 012 - 2 013
CABLE MANAGEMENT SYSTEMS
SYSTEMS WITH MAINTAINED FUNCTIONALIT Y IN FIRE
2012
CABLE PROTECTION DUCTS