Ingal Lintels

Page 1

INGAL BUILDING BUILDING SYSTEMS SYSTEMS

WWW.INDGALV WWW IN D GA LV. CO COM. M AU AU

LINTELS

THE LIGHTWEIGHT LINTEL THAT GIVES MAXIMUM PERFORMANCE.

DEVELOPED IN AUSTRALIA FOR SUPPORTING BRICKWORK IN AUSTRALIAN HOMES.

-- Hot 1 Hot dip dip galvanized galvanized to to AS/NZS AS/NZS 468046801999 999 -- Complies Complies with with durability durability ratings ratings up up to to R3 R3 of of AS/NZS AS/NZS 2699.3 2699.3 -- Cost Cost savings savings compared compared to to conventional conventional arch arch bars bars




MAXIMUM CLEAR SPAN

RAFTER/TRUSS SPAN IN METRES

TYPE OF CONSTRUCTION 3

4

5

6

7

8

9

10

1

1

LOADING CATEGORIES

LINTEL *100 X 100

LINTEL *150 X 100

1800

2800

1800 1600 1500 1100

2800 2300 1900 1600

1800

2800

1600

2300

1500

1900

1800

2800

1600

2300

1500

1900

1100

1600

TYPE A Brick veneer constructions with non load-bearing brickwork. Roof structure supported on timber frame

1

1

1

TYPE B

1

1

1

Lightweight metal roof and ceiling supported on single skin brickwork

TYPE C

1

Double Cavity brick roof supported uniformly on both skins of brickwork

1

1

1

1

2

2

1

1

3

4

4

1 2 3

TYPE D

3

1

Tiled roof with truss/rafter construction supported on a single skin of brickwork

2 3 4

4 5

5

5

REFER DESIGN TO A STRUCTURAL ENGINEER

TYPE E

REFER DESIGN TO A STRUCTURAL ENGINEER

Lower floor of two storey construction

The above table is provided as a guide for a range of loading applications. Many more loading applications are possible and a comprehensive stock range is manufactured for your selection.

STANDARD STOCK SIZES Length (metres)

INGAL Lintels Section Size (mm) *85 x 7 *100 x 100 x 6 *150 x 100 x 6

0.8

0.9

1.0

1.1

1.2

1.3

1.5

1.8

The required INGAL Lintel length is listed maximum clear INGAL Lintel span plus twice the required end bearing which for structural (load bearing) brickwork is typically: * 100mm x 100mm INGAL Lintel ~ All spans up to 1800mm = Clear Span + 200mm * 150mm x 100mm INGAL Lintel ~ All spans = Clear Span + 300m

2.1

2.4

2.7

3.0

3.3

3.6

4.0

Available from

N.B. Where the brickwork does not comply with the ‘Brickwork Code’, the bearing capacity of the brickwork should be checked by a Structural Engineer. NOTE: The information in this publication is provided for use as a GUIDE ONLY. Except to the extent that responsibility cannot lawfully be excluded, Industrial Galvanizers Corporation Pty Ltd (”IGC”) does not accept responsibility for any loss or damage of any kind however arising in connection with the selection and use of INGAL Lintel. IGC recommends that professional advice be sought in the selection and use of INGAL Lintel.

TOLLFREE: 1800 701 555