Bosch Test Specifications Instructions for testing PE-a & PE-B
Instructions for Testing Injection Pumps
PE..A.. and PE..B.. and Governors
Page
I. General Hints 1
A) Testing Conditions 2
B) Inspection and Preliminary Test . 2
C) Sequence of Operations .
D) Direction of Rotation
II. Adjusting the Commencement of Delivery
A) General ..... . . . 3
B) Preparations for Testing .
C) Setting the Pre-Stroke . 4
D) Marking the Commencement (or End) of De .e?v 6
HI. Checking the Delivery Quantity
A) General ...... . 6
B) Adjusting the Adaptor Valves
C) Setting initial compresslon of No-i-z e -e? F Vaives . 8
D) Adjustment of Delivery Quantity
IV. Testing Various Governors
A) General Hints on Centrifi.;go: Gevernes . . 9
B) Idling and Maximum Speed Gove?-ers 7,ices R. and RP 11
C) Variable Range Speed Governeor . 12
D) (Sliding Block-) Idling and Seeezt C.7overnor, Type RO 12
E) (Sliding Block-) Variable Range Speed, Ge.e?er. Type ROV 14
F) Pneumatic Governors, Types