1 Hardware Quick Start 1.1 Power Input and Consumption 1.1.1 Power Control Box for 100V
The 100V (100~120V) Power input consists of two cables. AC2 cable has three lines, (L/N and ground).
N (Black)
L (RED)
Ground (Green)
AC1 is for Inverter. AC1 consists of a Red line and a black line. Please follow the instruction to setup your power cable as below. You need two power cables to connect the terminal and the power source. AC1
AS for the detail of the cable, please refer to the table as below. AC1 (Inverter)
AC2
Line Number 2
3
Descriptions Line (Red)
Line (Red)
Neutral (Black)
AC2
Neutral (Black) Ground (Green)
Requirement 7A@110VAC (Max.) 12A@110VAC (Max.)
Copyright © 2007 DynaScan Technology Corp.
NOTE: The Power Cable connected to the Power Supply is Optional.
1
Ver.1
DS0808 Quick Start Guide
1.1.2 Power Control Box for 220V L (RED)
N (Black) Ground (Green)
The 220V (200~240V) Power Control box has one AC power cable. The requirement is 9A (Power Control Box plus Light box). Please follow the instruction to setup your power cable as below. Connect the power source and terminal with your power cable. AC2
AC2
Line Number
3
Descriptions
Line (Red) Neutral (Black) Ground (Green)
Requirement
9A @220VAC(Max.)
NOTE: The Power Cable connected to the Power Supply is Optional.
Copyright Š 2007 DynaScan Technology Corp.
2
Ver.1
DS0808 Quick Start Guide
1.2 IPC Installation Please install: 1. Dummy VGA Monitor 2. Audio Cable as the diagram. 2. Audio Cable z Output the audio of Capture card to PC z Please Connect the Audio Out and Line In as it shows Mouse Keyboard
Line In Line Out Mic In
8 in 1 Card Reader
Tuner In, AV In, Audio In, S-Video In, Audio Out Power Button PowerSwitch, Switch,Rest Reset Button
USB
COM2 COM1
RJ-45 DVI Out
Power USB
VGA Out
Copyright Š 2007 DynaScan Technology Corp.
Speaker (R) Speaker (L) Volume External Audio In External Enable Switch
1. Dummy VGA Monitor z Please Refer to the Appendix for more Info
Use the NTSC/Pal switch connector for the Capture Card if needed.
3
Ver.1
DS0808 Quick Start Guide
1.3 Display Operation 1.3.1 Display ON / OFF Manually The Panel contains Power switch, circuit breaker and cable connectors. Steps for 100V Power Control Box
Steps for 220V Power Control Box
1. Turn ON/OFF the display. Please turn the Power
1. Turn ON/OFF the display. Please turn the Power switch (1).
switch (1). 2. Turn ON/OFF the Inverter (2). 1
2
Reserve
Circuit Breaker
Copyright Š 2007 DynaScan Technology Corp.
1
Reserve
Circuit Breaker
4
Ver.1
DS0808 Quick Start Guide
Turn on: Turn on the main power switch (Power Control Box) then IPC will power on. Turn off: Turn off the power switch of the IPC. NOTE: If the operating system crashes, please press reset button to restart the IPC and then press power switch again.
1.3.2 Display ON / OFF Automatically You can preset on and off for the display and IPC at a certain time through the software application. When the preset time is up, the display will be powered on automatically, and the IPC will be triggered to power itself on too. If you have preset the item of startup in the software application, the content of the assigned schedule or external multimedia device will be played automatically. (Refer to the software manual for details) NOTE: The main power switch must be always on.
Copyright Š 2007 DynaScan Technology Corp.
5
Ver.1
DS0808 Quick Start Guide
1.3.3 IPC Operation You can use LCM panel to operate the IPC without keyboard and mouse. Display
Power Indicator
Basic Operation: ENTER:Enter the selected item or save the setting ESC:Go back or Cancel the setting Up/Down: Move the Cursor(>)or
Command Buttons
Change the settings
1.3.4 Put / Change Contents Insert Flash Media card* 1 ,such as MS/MS PRO, SmartMedia, CF/MicroDrive and SD/MMC, into 8-in-1 Card Reader for content playing.
*1
Not include a Flash Media card.
Copyright © 2007 DynaScan Technology Corp.
6
Ver.1
DS0808 Quick Start Guide
Steps
1. Save contents to a Flash Media card. (Media files must put in the root directory when you use LCM playing.) 2. Insert media card into the 8-in-1 Card Reader. 3. Choose the control item “Player Control”.
4. Choose the sub-menu “File Source”.
5. Select “All Content” to play the all media.
NOTE: 1.Refer to P.18~19 “Operation Tree of the IPC LCM” for more menu items, please. 2. For more instruction of IPC, please refer to the IPC User Manual.
Copyright © 2007 DynaScan Technology Corp.
7
Ver.1
DS0808 Quick Start Guide
1.3.5 Spin Speed Setting The spin speed of the display images. The more “X” is the faster it spins. Steps 1.
Choose the control item “Monitor System”.
2.
Press Up to increase, or Down to decrease. “Fixed” means to stop spinning.
NOTE: 1.Refer to P.18~19 “Operation Tree of the IPC LCM” for more menu items, please. 2. For more instruction of IPC, please refer to the IPC User Manual.
Copyright © 2007 DynaScan Technology Corp.
8
Ver.1
DS0808 Quick Start Guide
1.4 Light Box Operation
Power Button of Fluorescent Lamps
Turn ON/OFF the Light Box. Please Press the Power switch.
1.4.1 Timer Setting Panel
Circuit Breaker
Operate selector with indicator
Manual Switch
Timer for Light Box Power indicator Dial Knob
ON is Always ON OFF is Always OFF
Time Setting Bracket Storage compartment
Set present time: Rotate the center knob in the arrow direction (i.e. clockwise) to set the time. The present time can be set in 1-minute units. (For example, 16:31 as shown in the figure) Don’t rotate the knob counterclockwise. Insert the Time brackets: Two kinds of Time setting brackets are provided, ON (Gold) and OFF (Silver). The time segmentation unit is 15 minutes. Timer Chart
ON time setting
OFF time setting
24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Copyright Š 2007 DynaScan Technology Corp.
9
Ver.1
DS0808 Quick Start Guide
2 Function / Maintenance Introduction 2.1 AP3 Quick Operation 2.1.1 Start Program To activate AP3, click “START/Programs/ DynaScan AP3/DSPlayer to Start. Normally, the AP3 is running if PC power on when your computers are from DynaScan. Double click and AP3 will be restored.
2.1.2 Main Menu and Functions of Buttons Four Sections on Main Menu Section 1. Those buttons are the main Menu of AP3 Section 2. Video Play control: This part is the control bar for controlling the playing item Section 3. Function operation area. Section 4. Display monitor system.
Copyright © 2007 DynaScan Technology Corp.
10
Ver.1
DS0808 Quick Start Guide
2.1.3 Schedule Editing To setup the background sequence file,
5.
Click
1.
Set the Media type as Sequence File
6.
Set the Media type as Sequence File.
2.
Click
7.
Drag the editing file as following picture.
3.
Drag the file to the box as following picture.
8.
Select the media file you need.
4.
Save the sequence editing file.
9.
Drag the file to the box and editing schedule.
to select path and select the file you need.
Copyright Š 2007 DynaScan Technology Corp.
to select schedule editing.
11
Ver.1
DS0808 Quick Start Guide
2.1.4 Edit Layout Presetting Layout AP3 provides seven layout settings. Click the layout you want, AP3 will load the layout into the editing section and you can start to edit. The Preset layouts are undeletable.
Content Setting There is no content for newly made layout frames. If you do not assign any content to one frame, it will display a black ground when playing. Click
Start Run button to summon the Startup Run Setup window, and then assign
the content and the description of this content. The content with parameters to adjust will show the
button
beside description, and you can click it to setup.
Copyright Š 2007 DynaScan Technology Corp.
12
Ver.1
Copyright Š 2007 DynaScan Technology Corp.
DS0808 Quick Start Guide
13
Ver.1
DS0808 Quick Start Guide
2.1.5 Image Spin Speed Select the spin speed of the image(s) on the display screen. It is a drop-down list, and the options cannot be changed, 8 Sec, 16 Sec, -- to 120 Sec. The 8 Sec. means the drum image takes 8 seconds to rotate a round. The default setting is “Fixed”. This means that image(s) is displayed on the screen in a fixed position. You can choose any of them to fit your needs.
Copyright © 2007 DynaScan Technology Corp.
14
Ver.1
DS0808 Quick Start Guide
2.2 Ground Mounting For Safety Reason, you must do the ground mounting to fix the display on the ground. Steps 1.
Stop the casters.
2.
Lift the display a little up by counterclockwise turning the stoppers.
Copyright Š 2007 DynaScan Technology Corp.
15
Ver.1
DS0808 Quick Start Guide
2.3 Caster Decoration Circle 1. Put the Bracket under the base and align with the four
2. Use a screw driver to fasten
3. Fasten the decoration semicircle with
the bracket with four screws.
screws. Please fasten another side of the circle with the same procedure.
screw holes.
Note: You can follow the direction to setup another bracket on the opposite side of the base. 4. Fasten another semicircle as 5. Setup the plastic cover as the picture shows. the procedure as above.
Note: Please make sure that you align the tenons with the mortises.
Note: Pleas setup the center cover first as the picture shows, or you may not setup other cover properly. Copyright Š 2007 DynaScan Technology Corp.
16
Ver.1
DS0808 Quick Start Guide
3 Reference 3.1 Specifications Model LED Type Pitch (H x V)
DS0808 Chip 2.0mm x 2.0mm
Resolution
1366 x 384 x 1 screen
Brightness
> 750 cd/㎡
Color
16.7 millions
Contrast Ratio Screen Size (Diagonal) Total Display Area (W x H)
> 5000 : 1 62” Diagonal x 2 1.36 m x 0.77 m x 2
Viewing Angle(H x V)
>170 o x 120 o
Display Area (D x H)
Φ0.87M x 0.77M
Physical Dimension (D x H) Physical Weight Power Supply Color Spectrum Safe Ambient Temperature Fluorescent lamps (not included) Copyright © 2007 DynaScan Technology Corp.
Φ1 M x 2.03 M 350Kg 100~120 VAC, 50/60 Hz, 1Φ (110V), 25A or 200~240 VAC, 50/60 Hz, 1Φ (220V),15A Red: 660nm Green: 525nm Blue: 470nm From 0o to 30 o C Unit : Eight pieces (8), 30W, Length: 895mm 17
Ver.1
DS0808 Quick Start Guide
3.2 Operation Tree of the IPC LCM Main Menu
Menu Level 1
Menu Level 2
Menu Level 3
Main Menu
Menu Level 1
Monitor System
Spin Speed Power On Power Off Adj Dis Forward Adj Dis Reverse Temperature Power / Motor System Run Time System Alarm Virtual Enc. Brightness LEDM ON/OFF
Play All Close Select Frame
Player Control
Media File Picture File One File -------------- Sequence File Schedule File File Source --------Layout File All Media All Picture All Content SVideo Video Source ------- AV Tuner Channel Play Pause Play Operator ------- Stop Next Prev. Volume One Two Layout ---------------- Clone Two Clone Three CF/MicroDrive SD/MMC Content Device ----- MS/MSPro SmartMedia Hard Disk
Copyright Š 2007 DynaScan Technology Corp.
Menu Level 2
Menu Level 3
18
Ver.1
DS0808 Quick Start Guide
Main Menu
Menu Level 1
Menu Level 2
Menu Level 3
Main Menu
OS Protect Clock Country Code Tuner ----------------
Network --------------
Auto Run -----------Option Setting Watchdog------------
Window Adjust -----
Display Setting -----Video Out -------------
Input Type -----------
Cable Antenna
Input Pin DHCP Enable IP Address Subnet Mask Default Gateway Set Cancel Host Name Startup Startup Time Shutdown Shutdown Time Reboot Reboot Time Watchdog Watchdog Timer Left Pos. Top Pos Width Height Brightness Contrast Gamma DVI VGA
Test Pattern
Menu Level 1
Menu Level 2
Menu Level 3
White Red Green Pure Color ---------- Blue No Red No Green No Blue White Red Green Level Color ---------- Blue No Red No Green No Blue
Back Light CF/Micro Drive SD/MMC MS/MSPRO Smart Media Stable Embedded OS------Unstable Update Program----
NOTE: For more instruction of IPC, Please refer to the IPC User Manual.
Copyright Š 2007 DynaScan Technology Corp.
19
Ver.1
DS0808 Quick Start Guide
3.3 AP3 Default Settings Click
to start option settings. Default settings are shown below.
Setting Function \ Model
DS0808
Remark
Items Select Model
DS0808
Default setting.
VMR9_WL
Default setting.
Screen Type
Screen2
Default setting.
Auto Startup
Enable
Accelerator
Biling Record Enable Startup Computer ID
User Define User Define
Setting VMR9_RL Frame Reversal
Disable
Content in Sequence Preload
User Define
Content in Schedule Preload
User Define
Sequence in Schedule Preload
User Define
Copyright Š 2007 DynaScan Technology Corp.
To auto activate AP3 when the computer starts. Activate the function to keep the log. It needs to reopen AP3 to enable the setting. To set a computer ID number for Biling Record for easy maintenance. It's necessary to check it when you'd like to display a upside down content. Select VMR9_RL as accelerator and close it. Reopen AP3 to enable the setting. To shorten the blank interval between clips. It only supports Media File, Capture & Picture. Accelerator VMR9 _ WL supports this function. To shorten the blank interval between clips. It only supports Media File, Capture & Picture. To shorten the blank interval between clips. It only supports Media File, Capture & Picture.
20
Ver.1
DS0808 Quick Start Guide
Setting Function \ Model
DS0808
Remark
Items Serial Port Protocol Ver.
COM3 Auto
Select Monitor System connection port. Default setting is COM3. Select a correct monitor system edition. Default setting is Auto. Forward: Move the screen clockwise.
Display Adjust
User Define
Reverse: Move the screen counterclockwise. Save: Save the setting. Forcefully turn ON or OFF the display power. After Power off, you can’t power on the display until six minutes
Monitor System
later. This is for the safety reason. However you can power on the display before the countdown is due by pressing the “Force Power Power Control Enable
Enable
On”. Warning: “Force Power On” may cause damage to the display. Please don’t press the button unless you are sure that the display is completely stop operating. Check the checkbox to enable the setting. When the IPC is turned
Outside Power Off Enable
Disable
off by any way except the shutdown time, such as pressing the Power button. IPC will shut the display as well.
NOTE: For more instruction of AP3, please refer to the AP3 Software Manual. Copyright © 2007 DynaScan Technology Corp.
21
Ver.1
DS0808 Quick Start Guide
3.4 Legal Notices In te lle ctu al property; limited license to users T he ha rdwa re and so ftwa re o f our pr oduc ts a re pro tec te d b y c op yr ig h t, tr ademark , pa ten t, a nd /o r o the r in te llec tu al pro per ty laws , a nd a n y un au th or ized use o f the s oftwa re , tra de marks co ntaining h ere in ma y vio la te s uch laws and the so ftwa re lic ense a gre eme n t. Excep t as e x press l y p r o v ide d he r e in , D yna Sc an a nd i ts s upp l iers d o no t gra n t an y e xp r ess or i mp l ied r ig hts to use an y p roduc t r e la te d h ardw are a nd so ftwar e. D yn a Scan is re g istered tr ad ema rk o f D yna Sca n Tech nolog y C orp . in R .O .C an d \or other co un tr ies . Micr oso ft is re g istered tr ad ema rk o f Mic roso ft Cor p . Mo on ligh t is r eg is tere d t r a de mark o f Moo n li gh t c or d les s L td . I B M is re g istered tr ad ema rk o f IBM Co rpor a tion . O ther tra de marks ar e tra demarks o f the ir r espec tive owne rs . D is c la i me r Sp eci fica tio ns and information contained herein are furnished for informational use only. Revisions are periodically made to the information herein; these revisions will be incorporated in later editions. Improvements or changes in the products or the programs described may be made at any time and are subject to change without notice, and should not be construed as a commitment made by DynaScan. This manual could include mistyping or typographical errors. DynaScan assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. E x c lus i on o f D a ma ges : D yn a Sc a n Tec h n o lo g y C o r p o r a t ion ’s l ia b i l i t y i s lim i ted t o t h e c o s t o f r e pair o r r e p la ce me n t o f the pr oduc t. D yn a Sc an Tec hno lo g y C o r por a ti on s ha ll no t b e l ia bl e for : 1 . Da ma ges to o ther prop er ty c ause d b y a n y d e fec t in the pr oduc t, d amages bas ed up on inco n ven ienc e , loss of us e o f the pr oduc t, loss o f time , loss o f p ro fits , loss o f b usiness o p p o r tu n i t y, l o s s o f g o o d w i l l , i n ter fe r e n c e w it h b u s in e s s r e l a ti o n s h ips , o r o th e r c o mm erc ia l l os s , e v en i f ad v is e d o f t he p os s i b il i t y o f s uc h da mag es . 2 . An y other d amages , wh e the r inc ide ntal, co nseq uen tia l o r o th erw ise . 3 . A n y c la im a ga ins t th e c us t ome r b y an y o t he r par t y. Copyright Š 2007 DynaScan Technology Corp.
22
Ver.1
DS0808 Quick Start Guide
3.5 Disposal Notices Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new one, the retailer is legally obligated to take back your old appliances for disposal at least for free of charge.
Copyright Š 2007 DynaScan Technology Corp.
23
MEMO