1 Hardware Quick Start 1.1 Power Input and Consumption 1.1.1 Power Control Box for 100V

The 100V (100~120V) Power input consists of two cables. AC2 cable has three lines, (L/N and ground).

N (Black)

L (RED)

Ground (Green)

AC1 is for Inverter. AC1 consists of a Red line and a black line. Please follow the instruction to setup your power cable as below. You need two power cables to connect the terminal and the power source. AC1

AS for the detail of the cable, please refer to the table as below. AC1 (Inverter)

AC2

Line Number 2

3

Descriptions Line (Red)

Line (Red)

Neutral (Black)

AC2

Neutral (Black) Ground (Green)

Requirement 7A@110VAC (Max.) 12A@110VAC (Max.)

Copyright © 2007 DynaScan Technology Corp.

NOTE: The Power Cable connected to the Power Supply is Optional.

1


Ver.1

DS0808 Quick Start Guide

1.1.2 Power Control Box for 220V L (RED)

N (Black) Ground (Green)

The 220V (200~240V) Power Control box has one AC power cable. The requirement is 9A (Power Control Box plus Light box). Please follow the instruction to setup your power cable as below. Connect the power source and terminal with your power cable. AC2

AC2

Line Number

3

Descriptions

Line (Red) Neutral (Black) Ground (Green)

Requirement

9A @220VAC(Max.)

NOTE: The Power Cable connected to the Power Supply is Optional.

Copyright Š 2007 DynaScan Technology Corp.

2


Ver.1

DS0808 Quick Start Guide

1.2 IPC Installation Please install: 1. Dummy VGA Monitor 2. Audio Cable as the diagram. 2. Audio Cable z Output the audio of Capture card to PC z Please Connect the Audio Out and Line In as it shows Mouse Keyboard

Line In Line Out Mic In

8 in 1 Card Reader

Tuner In, AV In, Audio In, S-Video In, Audio Out Power Button PowerSwitch, Switch,Rest Reset Button

USB

COM2 COM1

RJ-45 DVI Out

Power USB

VGA Out

Copyright Š 2007 DynaScan Technology Corp.

Speaker (R) Speaker (L) Volume External Audio In External Enable Switch

1. Dummy VGA Monitor z Please Refer to the Appendix for more Info

Use the NTSC/Pal switch connector for the Capture Card if needed.

3


Ver.1

DS0808 Quick Start Guide

1.3 Display Operation 1.3.1 Display ON / OFF Manually The Panel contains Power switch, circuit breaker and cable connectors. Steps for 100V Power Control Box

Steps for 220V Power Control Box

1. Turn ON/OFF the display. Please turn the Power

1. Turn ON/OFF the display. Please turn the Power switch (1).

switch (1). 2. Turn ON/OFF the Inverter (2). 1

2

Reserve

Circuit Breaker

Copyright Š 2007 DynaScan Technology Corp.

1

Reserve

Circuit Breaker

4


Ver.1

DS0808 Quick Start Guide

Turn on: Turn on the main power switch (Power Control Box) then IPC will power on. Turn off: Turn off the power switch of the IPC. NOTE: If the operating system crashes, please press reset button to restart the IPC and then press power switch again.

1.3.2 Display ON / OFF Automatically You can preset on and off for the display and IPC at a certain time through the software application. When the preset time is up, the display will be powered on automatically, and the IPC will be triggered to power itself on too. If you have preset the item of startup in the software application, the content of the assigned schedule or external multimedia device will be played automatically. (Refer to the software manual for details) NOTE: The main power switch must be always on.

Copyright Š 2007 DynaScan Technology Corp.

5


Ver.1

DS0808 Quick Start Guide

1.3.3 IPC Operation You can use LCM panel to operate the IPC without keyboard and mouse. Display

Power Indicator

Basic Operation: ENTER:Enter the selected item or save the setting ESC:Go back or Cancel the setting Up/Down: Move the Cursor(>)or

Command Buttons

Change the settings

1.3.4 Put / Change Contents Insert Flash Media card* 1 ,such as MS/MS PRO, SmartMedia, CF/MicroDrive and SD/MMC, into 8-in-1 Card Reader for content playing.

*1

Not include a Flash Media card.

Copyright © 2007 DynaScan Technology Corp.

6


Ver.1

DS0808 Quick Start Guide

Steps

1. Save contents to a Flash Media card. (Media files must put in the root directory when you use LCM playing.) 2. Insert media card into the 8-in-1 Card Reader. 3. Choose the control item “Player Control”.

4. Choose the sub-menu “File Source”.

5. Select “All Content” to play the all media.

NOTE: 1.Refer to P.18~19 “Operation Tree of the IPC LCM” for more menu items, please. 2. For more instruction of IPC, please refer to the IPC User Manual.

Copyright © 2007 DynaScan Technology Corp.

7


Ver.1

DS0808 Quick Start Guide

1.3.5 Spin Speed Setting The spin speed of the display images. The more “X” is the faster it spins. Steps 1.

Choose the control item “Monitor System”.

2.

Press Up to increase, or Down to decrease. “Fixed” means to stop spinning.

NOTE: 1.Refer to P.18~19 “Operation Tree of the IPC LCM” for more menu items, please. 2. For more instruction of IPC, please refer to the IPC User Manual.

Copyright © 2007 DynaScan Technology Corp.

8


Ver.1

DS0808 Quick Start Guide

1.4 Light Box Operation

Power Button of Fluorescent Lamps

Turn ON/OFF the Light Box. Please Press the Power switch.

1.4.1 Timer Setting Panel

Circuit Breaker

Operate selector with indicator

Manual Switch

Timer for Light Box Power indicator Dial Knob

ON is Always ON OFF is Always OFF

Time Setting Bracket Storage compartment

Set present time: Rotate the center knob in the arrow direction (i.e. clockwise) to set the time. The present time can be set in 1-minute units. (For example, 16:31 as shown in the figure) Don’t rotate the knob counterclockwise. Insert the Time brackets: Two kinds of Time setting brackets are provided, ON (Gold) and OFF (Silver). The time segmentation unit is 15 minutes. Timer Chart

ON time setting

OFF time setting

24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Copyright Š 2007 DynaScan Technology Corp.

9


Ver.1

DS0808 Quick Start Guide

2 Function / Maintenance Introduction 2.1 AP3 Quick Operation 2.1.1 Start Program To activate AP3, click “START/Programs/ DynaScan AP3/DSPlayer to Start. Normally, the AP3 is running if PC power on when your computers are from DynaScan. Double click and AP3 will be restored.

2.1.2 Main Menu and Functions of Buttons Four Sections on Main Menu Section 1. Those buttons are the main Menu of AP3 Section 2. Video Play control: This part is the control bar for controlling the playing item Section 3. Function operation area. Section 4. Display monitor system.

Copyright © 2007 DynaScan Technology Corp.

10


Ver.1

DS0808 Quick Start Guide

2.1.3 Schedule Editing To setup the background sequence file,

5.

Click

1.

Set the Media type as Sequence File

6.

Set the Media type as Sequence File.

2.

Click

7.

Drag the editing file as following picture.

3.

Drag the file to the box as following picture.

8.

Select the media file you need.

4.

Save the sequence editing file.

9.

Drag the file to the box and editing schedule.

to select path and select the file you need.

Copyright Š 2007 DynaScan Technology Corp.

to select schedule editing.

11


Ver.1

DS0808 Quick Start Guide

2.1.4 Edit Layout Presetting Layout AP3 provides seven layout settings. Click the layout you want, AP3 will load the layout into the editing section and you can start to edit. The Preset layouts are undeletable.

Content Setting There is no content for newly made layout frames. If you do not assign any content to one frame, it will display a black ground when playing. Click

Start Run button to summon the Startup Run Setup window, and then assign

the content and the description of this content. The content with parameters to adjust will show the

button

beside description, and you can click it to setup.

Copyright Š 2007 DynaScan Technology Corp.

12


Ver.1

Copyright Š 2007 DynaScan Technology Corp.

DS0808 Quick Start Guide

13


Ver.1

DS0808 Quick Start Guide

2.1.5 Image Spin Speed Select the spin speed of the image(s) on the display screen. It is a drop-down list, and the options cannot be changed, 8 Sec, 16 Sec, -- to 120 Sec. The 8 Sec. means the drum image takes 8 seconds to rotate a round. The default setting is “Fixed”. This means that image(s) is displayed on the screen in a fixed position. You can choose any of them to fit your needs.

Copyright © 2007 DynaScan Technology Corp.

14


Ver.1

DS0808 Quick Start Guide

2.2 Ground Mounting For Safety Reason, you must do the ground mounting to fix the display on the ground. Steps 1.

Stop the casters.

2.

Lift the display a little up by counterclockwise turning the stoppers.

Copyright Š 2007 DynaScan Technology Corp.

15


Ver.1

DS0808 Quick Start Guide

2.3 Caster Decoration Circle 1. Put the Bracket under the base and align with the four

2. Use a screw driver to fasten

3. Fasten the decoration semicircle with

the bracket with four screws.

screws. Please fasten another side of the circle with the same procedure.

screw holes.

Note: You can follow the direction to setup another bracket on the opposite side of the base. 4. Fasten another semicircle as 5. Setup the plastic cover as the picture shows. the procedure as above.

Note: Please make sure that you align the tenons with the mortises.

Note: Pleas setup the center cover first as the picture shows, or you may not setup other cover properly. Copyright Š 2007 DynaScan Technology Corp.

16


Ver.1

DS0808 Quick Start Guide

3 Reference 3.1 Specifications Model LED Type Pitch (H x V)

DS0808 Chip 2.0mm x 2.0mm

Resolution

1366 x 384 x 1 screen

Brightness

> 750 cd/㎡

Color

16.7 millions

Contrast Ratio Screen Size (Diagonal) Total Display Area (W x H)

> 5000 : 1 62” Diagonal x 2 1.36 m x 0.77 m x 2

Viewing Angle(H x V)

>170 o x 120 o

Display Area (D x H)

Φ0.87M x 0.77M

Physical Dimension (D x H) Physical Weight Power Supply Color Spectrum Safe Ambient Temperature Fluorescent lamps (not included) Copyright © 2007 DynaScan Technology Corp.

Φ1 M x 2.03 M 350Kg 100~120 VAC, 50/60 Hz, 1Φ (110V), 25A or 200~240 VAC, 50/60 Hz, 1Φ (220V),15A Red: 660nm Green: 525nm Blue: 470nm From 0o to 30 o C Unit : Eight pieces (8), 30W, Length: 895mm 17


Ver.1

DS0808 Quick Start Guide

3.2 Operation Tree of the IPC LCM Main Menu

Menu Level 1

Menu Level 2

Menu Level 3

Main Menu

Menu Level 1

Monitor System

Spin Speed Power On Power Off Adj Dis Forward Adj Dis Reverse Temperature Power / Motor System Run Time System Alarm Virtual Enc. Brightness LEDM ON/OFF

Play All Close Select Frame

Player Control

Media File Picture File One File -------------- Sequence File Schedule File File Source --------Layout File All Media All Picture All Content SVideo Video Source ------- AV Tuner Channel Play Pause Play Operator ------- Stop Next Prev. Volume One Two Layout ---------------- Clone Two Clone Three CF/MicroDrive SD/MMC Content Device ----- MS/MSPro SmartMedia Hard Disk

Copyright Š 2007 DynaScan Technology Corp.

Menu Level 2

Menu Level 3

18


Ver.1

DS0808 Quick Start Guide

Main Menu

Menu Level 1

Menu Level 2

Menu Level 3

Main Menu

OS Protect Clock Country Code Tuner ----------------

Network --------------

Auto Run -----------Option Setting Watchdog------------

Window Adjust -----

Display Setting -----Video Out -------------

Input Type -----------

Cable Antenna

Input Pin DHCP Enable IP Address Subnet Mask Default Gateway Set Cancel Host Name Startup Startup Time Shutdown Shutdown Time Reboot Reboot Time Watchdog Watchdog Timer Left Pos. Top Pos Width Height Brightness Contrast Gamma DVI VGA

Test Pattern

Menu Level 1

Menu Level 2

Menu Level 3

White Red Green Pure Color ---------- Blue No Red No Green No Blue White Red Green Level Color ---------- Blue No Red No Green No Blue

Back Light CF/Micro Drive SD/MMC MS/MSPRO Smart Media Stable Embedded OS------Unstable Update Program----

NOTE: For more instruction of IPC, Please refer to the IPC User Manual.

Copyright Š 2007 DynaScan Technology Corp.

19


Ver.1

DS0808 Quick Start Guide

3.3 AP3 Default Settings Click

to start option settings. Default settings are shown below.

Setting Function \ Model

DS0808

Remark

Items Select Model

DS0808

Default setting.

VMR9_WL

Default setting.

Screen Type

Screen2

Default setting.

Auto Startup

Enable

Accelerator

Biling Record Enable Startup Computer ID

User Define User Define

Setting VMR9_RL Frame Reversal

Disable

Content in Sequence Preload

User Define

Content in Schedule Preload

User Define

Sequence in Schedule Preload

User Define

Copyright Š 2007 DynaScan Technology Corp.

To auto activate AP3 when the computer starts. Activate the function to keep the log. It needs to reopen AP3 to enable the setting. To set a computer ID number for Biling Record for easy maintenance. It's necessary to check it when you'd like to display a upside down content. Select VMR9_RL as accelerator and close it. Reopen AP3 to enable the setting. To shorten the blank interval between clips. It only supports Media File, Capture & Picture. Accelerator VMR9 _ WL supports this function. To shorten the blank interval between clips. It only supports Media File, Capture & Picture. To shorten the blank interval between clips. It only supports Media File, Capture & Picture.

20


Ver.1

DS0808 Quick Start Guide

Setting Function \ Model

DS0808

Remark

Items Serial Port Protocol Ver.

COM3 Auto

Select Monitor System connection port. Default setting is COM3. Select a correct monitor system edition. Default setting is Auto. Forward: Move the screen clockwise.

Display Adjust

User Define

Reverse: Move the screen counterclockwise. Save: Save the setting. Forcefully turn ON or OFF the display power. After Power off, you can’t power on the display until six minutes

Monitor System

later. This is for the safety reason. However you can power on the display before the countdown is due by pressing the “Force Power Power Control Enable

Enable

On”. Warning: “Force Power On” may cause damage to the display. Please don’t press the button unless you are sure that the display is completely stop operating. Check the checkbox to enable the setting. When the IPC is turned

Outside Power Off Enable

Disable

off by any way except the shutdown time, such as pressing the Power button. IPC will shut the display as well.

NOTE: For more instruction of AP3, please refer to the AP3 Software Manual. Copyright © 2007 DynaScan Technology Corp.

21


Ver.1

DS0808 Quick Start Guide

3.4 Legal Notices In te lle ctu al property; limited license to users T he ha rdwa re and so ftwa re o f our pr oduc ts a re pro tec te d b y c op yr ig h t, tr ademark , pa ten t, a nd /o r o the r in te llec tu al pro per ty laws , a nd a n y un au th or ized use o f the s oftwa re , tra de marks co ntaining h ere in ma y vio la te s uch laws and the so ftwa re lic ense a gre eme n t. Excep t as e x press l y p r o v ide d he r e in , D yna Sc an a nd i ts s upp l iers d o no t gra n t an y e xp r ess or i mp l ied r ig hts to use an y p roduc t r e la te d h ardw are a nd so ftwar e. D yn a Scan is re g istered tr ad ema rk o f D yna Sca n Tech nolog y C orp . in R .O .C an d \or other co un tr ies . Micr oso ft is re g istered tr ad ema rk o f Mic roso ft Cor p . Mo on ligh t is r eg is tere d t r a de mark o f Moo n li gh t c or d les s L td . I B M is re g istered tr ad ema rk o f IBM Co rpor a tion . O ther tra de marks ar e tra demarks o f the ir r espec tive owne rs . D is c la i me r Sp eci fica tio ns and information contained herein are furnished for informational use only. Revisions are periodically made to the information herein; these revisions will be incorporated in later editions. Improvements or changes in the products or the programs described may be made at any time and are subject to change without notice, and should not be construed as a commitment made by DynaScan. This manual could include mistyping or typographical errors. DynaScan assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. E x c lus i on o f D a ma ges : D yn a Sc a n Tec h n o lo g y C o r p o r a t ion ’s l ia b i l i t y i s lim i ted t o t h e c o s t o f r e pair o r r e p la ce me n t o f the pr oduc t. D yn a Sc an Tec hno lo g y C o r por a ti on s ha ll no t b e l ia bl e for : 1 . Da ma ges to o ther prop er ty c ause d b y a n y d e fec t in the pr oduc t, d amages bas ed up on inco n ven ienc e , loss of us e o f the pr oduc t, loss o f time , loss o f p ro fits , loss o f b usiness o p p o r tu n i t y, l o s s o f g o o d w i l l , i n ter fe r e n c e w it h b u s in e s s r e l a ti o n s h ips , o r o th e r c o mm erc ia l l os s , e v en i f ad v is e d o f t he p os s i b il i t y o f s uc h da mag es . 2 . An y other d amages , wh e the r inc ide ntal, co nseq uen tia l o r o th erw ise . 3 . A n y c la im a ga ins t th e c us t ome r b y an y o t he r par t y. Copyright Š 2007 DynaScan Technology Corp.

22


Ver.1

DS0808 Quick Start Guide

3.5 Disposal Notices Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new one, the retailer is legally obligated to take back your old appliances for disposal at least for free of charge.