Overseas Safety Standards MODEL UL
US–602S US–602K US–603U US–603K
•
• •
C–UL CSA DEMKO VDE CCEE
• • • •
•
• •
• •
EN 60730
US–622
• •
• •
EN 60730
EN 60730
US–622K
• •
•
EN 60730
US–625 US–630U US–631
• •
•
•
•
US–802
• •
•
EN 60730
EN 60730
Specifications for UL Approval Products File No.E52529 Standard : TEMPERATURE–INDICATING AND REGULATING EQUIPMENT. UL873 Product Classification : COMPONENT–TEMPERATURE INDICATING AND REGULATING EQUIPMENT (XAPX2) UL Model
Rating
Maximum temperature rating
Durability
US–602S
AC 125V 15 A AC 250V 8 A (Resistive load)
160°C
(Limiting) (100,000times)
*US–602K
DC 30V 1A (Resistive) AC 120V 125 VA Pilot Duty
160°C
(Limiting) (100,000 times)
US–603U (US–603U–H)
AC 125 V 15 A AC 250 V 10 A (Resistive load) AC 120 V 12 A (Inductive load) 120 VAC, FLA 5.8 A, LRA 34.8 A 240 VAC, FLA 2.9A, LRA 17.4 A
160°C
(Protective switch) (6,000 times)
US–603K
DC 30 V 1 A (Resistive load) AC 120 V 125 VA Pilot Duty
160°C
(Protective switch) (6,000 times)
*US–622
AC 125V 15 A AC 250 V 10 A (Resistive load)
185°C
(Limiting) (100,000 times)
DC 30 V 1 A (Resistive load)
130°C
AC 120 V 125 VA Pilot Duty
160°C
*US–625
AC 125 V 15 A AC 250 V 10 A (Resistive load)
260°C
(Limiting) (100,000 times)
*US–802
48 VDC 1 A 125 VAC 1 A
120°C
(Limiting) (30,000 times)
US–630U
AC 120 V 5 A AC 120 V 2 A (Resistive load)
100°C
(Limiting) (100,000 times)
*US–622K
(Limiting) (100,000 times)
Mark's models are approved by C-UL (CSA) Regarding the variation of UL approved model (Terminal and cover and bracket type etc.), please contact us File No. E166395 Standard : THERMAL PROTECTORS FOR MOTORS. UL547 Product Classification : COMPONENT-MOTOR PROTECTIVE DEVICES-INHERENT OVERHEATING TYPE(XEWR2)
US–602S
AC 120 V FLA 5.8 A / LRA 34.8 A AC 240 V FLA 2.9 A / LRA 17.4 A (nductive load)
Regulating 100,000 times
160°C
File No.E 52529 US–602S
128