Advanced Residential Products
4-1
Advanced Residential Products
February 2007
CA08101001E
Contents Description
Page
Surge Protection Devices and Lightning Arresters . . . . . . . . . . . . . . . . . . . . Transfer Switch Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Portable Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standby Generator Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . StructuredWiringSolutions™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Arc Fault Circuit Interrupter (AFCI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2 4-11 4-14 4-15 4-21 4-31
Home Connected/Home Protected Products and Systems
For more information visit: www.eaton.com
4
4-2
Advanced Residential Products Surge Protection Devices and Lightning Arresters February 2007
Product Description
Product Description The Problem
The Solution Eaton’s electrical business has developed the most comprehensive family of surge protection devices and lightning arresters installed at service entrance and point-of-use locations, providing quality power required for sensitive electronic loads.
Application Description
CHSP installed at the service entrance panel. SurgeTrap surge traps and strips located where sensitive electronics are plugged in.
Two-Stage Protection The Institute of Electrical and Electronic Engineers (IEEE) recommends two stages of surge suppression to provide the best protection for electronic equipment. Two-stage surge suppression should be provided for all cables entering a home, including power, Internet, coaxial and telephone.
Stage 1: Primary Protection for Service Entrance The best place to install surge protection is at the electrical entrance point (loadcenter or breaker panel). This is often where ac power, telephone lines and cable lines are located. Applying a CHSP product to your service entrance (stage 1) will reduce a voltage surge to an acceptable level for appliances and surge strips. See Figure 4-2. For added protection, it is recommended that you install surge protection for your cable and telephone lines at the service entrance. Your ac, cable and telephone lines will all have the same ground potential, in one common location, for passing the surge away from your equipment.
Figure 4-1. Two-Stage Protection
20,000 V
Let Through Voltage (V)
4
Due to the evolution of electronics and microprocessors in the home, we are continually challenged to provide quality (clean) power for electronic loads such as appliances, computers/ home office and entertainment systems. Surges (also known as transients) due to lighting, utility grid switching and other sources travel on current carrying conductors throughout the home, which can effect and destroy sensitive electronic loads.
High Energy Transient Disturbance Input at Main Panel - IEEE Category C3 Impulse (Combination) Waveform, 20,000 V, 10,000 A
10,000 V Best Achievable Performance with CHSP at 120/240 Volt Loadcenter (Stage 1)
400 V Two stage use of Surge Strips (cascade approach ) achieves best possible surge protection (Stage 2)
0 25µS Time (microseconds)
50µS
Figure 4-2. Surge Voltage Remnant Comparison
Stage 2: Secondary Protection for Point of Use The Cutler-Hammer SurgeTrap surge strip is recommended for sensitive electronic loads like computers or entertainment centers. Using a SurgeTrap surge strip (stage 2) reduces any voltage remnant down to an acceptable level. For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Surge Protection Devices and Lightning Arresters
4-3
February 2007
Application Description
Stage 1 — Service Entrance Surge Protection Factory Installed
Telephone and Cable Accessories Type CHSP Surge Protection Eaton also offers a full range of accessory products for telephone and cable, including SurgeTel which protects up to four telephone/modem lines; SurgeCable which protects up to two cable/satellite lines; and SurgeEthernet featuring protection for high speed Internet hookups.
4 BRSURGE Surge Protector
Type BRSURGE
Surge Panel
Industry Breakthrough Eaton is the first to introduce a factory installed surge protection device that is mounted inside a 120/240 volt loadcenter.
Telephone, Cable and Ethernet
Lighting Arresters
Type CHSUR The CHSUR loadcenter provides a customer with the lowest system let-through voltage (best protection) when compared to traditional remote/side mounted devices. The Surge Panel is an internally mounted unit that provides industrial level surge protection in a residential design. The Surge Panel is available with 75 kA/phase surge current complete with thermal fusing and provides protection for all residential electrical equipment by reducing power surges, often caused by lightning, to an acceptable level for appliances and electronics.
Remote/Side Mounted Type CHSP Surge Protection The Cutler-Hammer Surge Protector (CHSP) is an externally mounted unit that provides industrial level surge protection in a residential design. The CHSP is available in four models and provides protection for all residential electrical equipment by reducing power surges, often caused by lightning, to an acceptable level for appliances and electronics. These units can be mounted in any manufacturer’s breaker panel (loadcenter).
CHSA Surge Protector
Type CHSA For use on single-phase 120/240 Vac systems. This easily plugs into a single-phase Type CH loadcenter and occupies two 3/4-inch (19.1 mm) pole spaces similar to a 2-pole Type CH breaker. When plugged into the first two stabs at the top of the loadcenter just below the main breaker or main lug, it provides surge protection for the entire loadcenter. If internal components are damaged, the CHSA LED visual indicators will signal the need for replacement. This device is suitable for service entry locations installed in accordance with NEC Article 280. The CHSA is ideal for protecting sensitive appliances and electronics, such as refrigerators, microwave ovens, and home computers.
ac Power (Also Includes Cable/Telephone)
CA08101001E
For use on single-phase 120/240 Vac systems. This easily plugs into a single-phase Type BR loadcenter and occupies two 1-inch (25.4 mm) pole spaces similar to a 2-pole Type BR breaker. When plugged into the first two stabs at the top of the loadcenter just below the main breaker or main lug, it provides surge protection for the entire loadcenter. If internal components are damaged, the BRSURGE LED visual indicators will signal the need for replacement. This device is suitable for service entry locations installed in accordance with NEC Article 280. The BRSURGE is ideal for protecting sensitive appliances and electronics, such as refrigerators, microwave ovens, and home computers.
For more information visit: www.eaton.com
CHQSA Surge Protector
Type CHQSA For use on single-phase, 120/240 Vac systems. This easily plugs into a Square D, single-phase loadcenter Type QO and occupies two 3/4-inch (19.1 mm) pole spaces similar to a standard 2-pole Type QO breaker. When plugged into the first two stabs at the top of the loadcenter just below the main breaker or main lug, it provides surge protection for the entire loadcenter. If internal components are damaged, the CHQSA LED visual indicators will signal the need for replacement. This device is suitable for service entrance locations installed in accordance with NEC Article 280 and are UL Classified to be used in place of Square D Type QO surge arresters. The CHQSA is ideal for protecting sensitive appliances and electronics, such as refrigerators, microwave ovens, and home computers.
4-4
Advanced Residential Products Surge Protection Devices and Lightning Arresters February 2007
Application Description
Service Entrance Surge Protection (Continued)
4
Point-of-Use Surge Protection Eaton’s Cutler-Hammer SurgeTrap , plug-in surge protectors offer exceptional protection for electrical and electronic devices. Each of the SurgeTrap Ultra, Max and Micro are available in ac only, ac plus telephone/modem and ac plus cable. The SurgeTrap Ultra 3Way, in addition to having the above options, is available in ac plus telephone/modem and cable.
CHSA01 Surge Protector
CHSA01 — For use on single-phase, 120/240 Vac systems. This surge protector can be easily installed in the enclosure of indoor or outdoor loadcenters by using the 1/2-inch (12.7 mm) threaded nipple. It is ideal for protecting outdoor lighting, garages, sump and irrigation pumps, etc.
Point-of-Use Surge Strips
CHSA03 Surge Protector
CHSA03 — For use on three-phase, 600 Vac systems. This surge protector can be easily installed in the enclosure of indoor or outdoor loadcenters by using the 1/2-inch (12.7 mm) threaded nipple. It provides protection for commercial electrical services especially those using electric motors.
For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Surge Protection Devices and Lightning Arresters
4-5
February 2007
Technical Data and Specifications
Technical Data and Specifications Table 4-1. Lightning Arresters Description
Discharge Voltage, Vac 1.5 kA
Surge Protector Plug-On Type CH, Single-Phase, 120/240 Vac Surge Protector Plug-On Type BR, Single-Phase, 120/240 Vac Surge Protector Plug-On Type CHQ, Single-Phase, 120/240 Vac Surge Protector, 2-Pole Single-Phase, 3-Wire, 120/240 Vac Surge Protector, 3-Pole Single-Phase, 4-Wire, 120/240 Vac
10 kA
Lead Length Inches (mm)
3 kA
5 kA
345 345 345
370 370 370
500 500 500
545 545 545
8.00 (203.2) 8.00 (203.2) 8.00 (203.2)
490 1700
640 2100
980 2510
1410 3800
15.00 (381.0) 15.00 (381.0)
Catalog Number CHSA BRSURGE CHQSA CHSA01 CHSA03
Table 4-2. Surge Protection Devices Description
System Voltage
Protection Surge Modes Current Capacity
UL Let- Telephone Coaxial through Protection Protection Voltage
Maximum Continuous Operating Voltage
EMI/RFI Capac- Installation/ Noise itance Enclosures Rejection (L-N)
Agency Catalog Approvals Number
CHSP Micro 120/240
L-G
20,000 A per Phase
400
—
—
150
—
—
Indoor/ Outdoor Enclosure
UL 1449 (2nd Ed.), CSA
CHSPMICRO
CHSP Max
120/240
L, L, N, G
50,000 A per Phase
400
—
—
150
—
—
Indoor/ Outdoor Enclosure
UL 1449 (2nd Ed.), CSA
CHSPMAX
CHSP 3-Way 120/240
L, L, N, G
75,000 A per Phase
400
4 Pair, Terminal Mount
Patented High 150 Frequency “F” Connectors 1 Line Protected
—
< 15pf, Indoor/ Low Flushmount Signal Enclosure Loss
UL 1449, UL497A, CSA
CHSPCHSR4P
CHSP Ultra
120/240
L, L, N, G
75,000 A per Phase
400
—
—
150
—
—
Indoor/ Outdoor Enclosure
UL 1449 (2nd Ed.), CSA
CHSPULTRA
SurgeTel
230 Vdc — Breakdown Voltage
10,000 A per Phase
—
2 or 4 Pair — UTP or Category 5 Lines
—
—
—
Indoor Application
UL 497A, CSA
DHW4PT
SurgeCable 145 Vdc — Breakdown Voltage
5,000 A per Phase
—
—
Patented High — Frequency “F” Connectors 2 Lines Protected
—
< 15pf, Indoor Low Application Signal Loss
UL 6500, CSA
DCXCAB2
NEMA 3R 120/240 Enclosure for SurgeTel and SurgeCable
—
—
—
—
—
—
—
UL 50 CHSP3RTELCABLE Enclosure
—
—
—
< 70pf Indoor Application
UL 497B
DRJ45D30R
150
Up to 15 dB (Peak)
—
UL 1449 (2nd Ed.), UL 1363, UL 497A, CSA
SGXMICROAC6
UL 1449 (2nd Ed.), UL 1363, UL 497A, CSA
SGXMAXAC
UL 1449 (2nd Ed.), UL 1363, UL 497A, CSA
SGXULTAC
UL 1449 (2nd Ed.), UL 1363, UL 497A, CSA
SGXRM19B
—
Surge Ethernet
30 Vdc — Breakdown Voltage
300 A per Phase
—
8 Wires (4 Pair)
SurgeTrap Micro
120
12,000 A per Phase 600 Joules Total
330
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
SurgeTrap Max
SurgeTrap Ultra
120
120
Rack Mount 120 Surge Strip
All Modes
All Modes
All Modes
All Modes
20,000 A per Phase 900 Joules Total
330
40,000 A 330 per Phase 1575 Joules Total 84,000 A 330 per Phase 1575 Joules Total
No
No
Yes
No
No
Yes
Yes
Yes
No
No
150
150
150
Up to 15 dB (Peak)
Up to 35 dB (Peak)
Yes
15 and 20 ampere available. 15 ampere twist lock ac cord.
CA08101001E
For more information visit: www.eaton.com
—
—
—
Outdoor Application
Indoor Application
Indoor Application
Indoor Application
Indoor Application
SGXMICRONET1 SGXMICRONET6 SGXMICROTV6 SGXMAXNET SGXMAXTV
SGXULTNET SGXULTTV SGXULT3WAY SGXRM19BTL
4
Advanced Residential Products Surge Protection Devices and Lightning Arresters
4-6
February 2007
Product Selection
Product Selection Table 4-3. Residential Surge Protection Devices and Lightning Arresters Product
Protection Levels and Application
Features
Warranty
Installation/ Enclosures
Catalog Number
Price U.S. $
CHSA
Basic Surge Protection
2-Pole Breaker Design
1 Year Product Warranty
Inside Type CH Loadcenter
CHSA
BRSURGE
Basic Surge Protection
2-Pole Breaker Design
1 Year Product Warranty
Inside Type BR Loadcenter/ Classified Listed
BRSURGE
CHQSA
Basic Surge Protection
2-Pole Breaker Design
1 Year Product Warranty
Inside Square D Type QO Loadcenter
CHQSA
CHSA01
Basic Surge Protection for Outdoor Lighting, Garages, Sump and Irrigation Pumps
120/240 Vac systems
1 Year Product Warranty
Indoor/Outdoor Enclosure
CHSA01
CHSA03
Basic Surge Protection for Commercial Electrical Services
600 Vac systems
1 Year Product Warranty
Indoor/Outdoor Enclosure
CHSA03
CHSP Micro
Basic Surge Protection for Appliances
Surge Current Rating 20 kA, Thermal Fusing, Compact, Small Footprint, Status Monitor
Lifetime Product Warranty $5,000 Connected Equipment
Indoor/Outdoor Enclosure
CHSPMICRO
CHSP Max
Standard Surge Protection for Major Appliances and Home Electronics
Surge Current Rating 50 kA, Thermal Fusing, Compact, Small Footprint, Status Monitor
Lifetime Product Warranty , $5,000 Connected Equipment
Indoor/Outdoor Enclosure
CHSPMAX
CHSP Ultra
Ultimate Surge Protection for Major Appliances, Home Electronics, Computers/home Office and Entertainment Systems
Surge Current Rating 75 kA, Thermal Fusing, Compact, Small Footprint, Status Monitor
Lifetime Product Warranty , $5,000 Connected Equipment
Indoor/Outdoor Enclosure
CHSPULTRA
CHSP 3-Way
Standard 3-Way Protection (ac Power, Phone, Cable) for All Home Electronic Equipment
Indoor Surge Current Rating 75 kA, Lifetime Product 4 Telephone Lines, Warranty , $10,000 Connected 1 Cable/Satellite Line Equipment
CHSPCHSR4P
SurgeTel
Telephone/Modems
4 Telephone Lines
Lifetime Product Warranty
—
DHW4PT
SurgeCable
Cable/Satellite TV
2 Cable/Satellite Lines
Lifetime Product Warranty
—
DCXCAB2
SurgeEthernet
Ethernet
Protection for High Speed Internet
Lifetime Product Warranty
—
DRJ45D30R
SurgeTrap Micro
Appliances
3 Outlets; Wallmount
Lifetime Product — Warranty, — $50,000 Connected Equipment —
SGXMICROAC6 SGXMICRONET1 SGXMICRONET6 SGXMICROTV6
SurgeTrap Max
Less Critical Electronic Equipment
7 Outlets; Angled plug-in
Lifetime Product — Warranty, — $75,000 Connected — Equipment
SGXMAXAC SGXMAXNET SGXMAXTV
SurgeTrap Ultra
Home Entertainment Systems and Computer/Home Office
8 Outlets; Angled Plug-in, Lifetime Product Transformer Spacing, Warranty, Series Filter and TCO Fuses $100,000 Connected Equipment
— — — —
SGXULTAC SGXULTNET SGXULTTV SGXULT3WAY
Stage 1
4
Accessories
Stage 2
Warranty coverage applicable when CHSP products are used in conjunction with SurgeTrap point-of-use strips and appropriate cable and telephone protectors (see accessories). ac power. ac + telephone/modem. ac + cable. ac + telephone/modem + cable.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Surge Protection Devices and Lightning Arresters
4-7
February 2007
Product Selection Table 4-4. Single-Phase Main Circuit Breaker Loadcenters with Factory Installed Surge Suppression — Indoor Single-Phase 3-Wire — 120/240 Vac — Factory Bonded Split Neutral Main Breaker Type
Maximum Main Ampere Rating
Maximum Box Number Size 3/4-Inch (19.1 mm) Single Poles
Wire Range Size
Loadcenter
CSH 35 kAIC
100
24 32
E K
#6 – 4/0
CHSUR24B100E CHSUR32B100K
CHSUR8EF CHSUR8KF
CHSUR8ES CHSUR8KS
150 200 200
32 32 42
K K L
#2 – 300 kcmil
CHSUR32B150K CHSUR32B200K CHSUR42B200L2
CHSUR8KF CHSUR8KF CHSUR8LF
CHSUR8KS CHSUR8KS CHSUR8LS
Catalog Number
Loadcenter Cover Price U.S. $
Combination Catalog Number
Price U.S. $
Surface Catalog Number
Price U.S. $
4
Combination style covers may be used for surface or flushmount applications.
Table 4-5. Single-Phase Main Lug Loadcenters with Factory Installed Surge Suppression — Indoor Single-Phase 3-Wire — 120/240 Vac — Twin Neutral — Factory Installed Ground Bar Maximum Main Ampere Rating
Maximum Number 3/4-Inch (19.1 mm) Single Poles
125
24
225
32 42
Box Size
Wire Range Size
Loadcenter
E
#6 – 2/0
CHSUR24L125E
CHSUR8EF
CHSUR8ES
K L
#2 – 300 kcmil
CHSUR32L225K CHSUR42L225L2
CHSUR8KF CHSUR8LF
CHSUR8KS CHSUR8LS
Catalog Number
Loadcenter Cover Price U.S. $
Combination Catalog Number
Price U.S. $
Surface Catalog Number
Price U.S. $
Combination style covers may be used for surface or flushmount applications.
Table 4-6. Single-Phase Convertible Loadcenters with Factory Installed Surge Suppression — Indoor Single-Phase 3-Wire — 120/240 Vac — Twin Neutral — Factory Installed Ground Bar Maximum Main Ampere Rating
Maximum Number 3/4-Inch (19.1 mm) Single Poles
Box Size
225
32 42
K L
Wire Range Size
Loadcenter
#2 – 300 kcmil
CHSUR32N225K CHSUR42N225L
Catalog Number
Loadcenter Cover Price U.S. $
Combination Catalog Number
Price U.S. $
CHSUR8KF CHSUR8LF
Surface Catalog Number
Price U.S. $
CHSUR8KS CHSUR8LS
Order main breaker kit separately. Combination style covers may be used for surface or flushmount applications.
Table 4-7. Single-Phase Main Circuit Breaker Loadcenters with Field Installation Provision for Surge Suppression — Indoor Single-Phase 3-Wire — 120/240 Vac — Factory Bonded Split Neutral Main Breaker Type
Maximum Main Ampere Rating
Maximum Box Number Size 3/4-Inch (19.1 mm) Single Poles
Wire Range Size
Loadcenter
CSH 35 kAIC
100
24 32
E K
#6 – 4/0
CHEC24B100E CHEC32B100K
CHSUR8EF CHSUR8KF
CHSUR8ES CHSUR8KS
150 200 200
32 32 42
K K L
#2 – 300 kcmil CHEC32B150K CHEC32B200K CHEC42B200L
CHSUR8KF CHSUR8KF CHSUR8LF
CHSUR8KS CHSUR8KS CHSUR8LS
Catalog Number
Loadcenter Cover Price U.S. $
Combination Catalog Number
Price U.S. $
Surface Catalog Number
Price U.S. $
Combination style covers may be used for surface or flushmount applications.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
Advanced Residential Products Surge Protection Devices and Lightning Arresters
4-8
February 2007
Product Selection Table 4-8. Single-Phase Main Lug Loadcenters with Field Installation Provision for Surge Suppression — Indoor Single-Phase 3-Wire — 120/240 Vac — Twin Neutral — Factory Installed Ground Bar
4
Maximum Main Ampere Rating
Maximum Number 3/4-Inch (19.1 mm) Single Poles
125
24
E
#6 – 2/0
CHEC24L125E
CHSUR8EF
CHSUR8ES
225
32 42
K L
#2 – 300 kcmil
CHEC32L225K CHEC42L225L
CHSUR8KF CHSUR8LF
CHSUR8KS CHSUR8LS
Box Size
Wire Range Size
Loadcenter Catalog Number
Loadcenter Cover Price U.S. $
Combination Price U.S. $ Catalog Number
Surface Catalog Number
Price U.S. $
Combination style covers may be used for surface or flushmount applications.
Table 4-9. Single-Phase Convertible Loadcenters with Field Installation Provision for Surge Suppression — Indoor Single-Phase 3-Wire — 120/240 Vac — Twin Neutral — Factory Installed Ground Bar Maximum Main Ampere Rating
Maximum Number 3/4-Inch (19.1 mm) Single Poles
Box Size
225
32 42
K L
Wire Range Size
Loadcenter Catalog Number
#2 – 300 kcmil
Loadcenter Cover Price U.S. $
CHEC32N225K CHEC42N225L
Combination Price U.S. $ Catalog
Surface
Number
Catalog Number
CHSUR8KF CHSUR8LF
CHSUR8KS CHSUR8LS
Price U.S. $
Combination style covers may be used for surface or flushmount applications.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Surge Protection Devices and Lightning Arresters
4-9
February 2007
Cross-Reference
Cross-Reference Note: Cross-Reference continues on the following page.
Table 4-10. Surge Products Description
CutlerHammer
Square D
General Electric
Siemens
Leviton
Intermatic
Pass & Seymour
120/240 Vac, Single-Phase, 3-Wire
CHSA01
SDSA1175
N/A
N/A
55175-ASA, 55175-SSA
AG2401
N/A
600 Vac, 3-Phase, 4-Wire, 3-Phase
CHSA03
SDSA3650
N/A
N/A
55650-ASA
AG6503, AG6503L
N/A
120/240 Vac, Type BR Circuit Breaker
BRSURGE
HOM2175SB
THQLSurge
QSA Series
N/A
N/A
N/A
120/240 Vac, Type CH Circuit Breaker
CHSA
QO2175SB
N/A
N/A
N/A
N/A
N/A
120/240 Vac, 20 kA Surge Current
CHSPMICRO
N/A
N/A
N/A
N/A
N/A
N/A
120/240 Vac, 50 kA Surge Current
CHSPMAX
N/A
THQLSurge60
SBPRIMAX, SSPRIMAX
51120-1, 51120-3R
IG1240RC
1224-SL
120/240 Vac, 70 kA Surge Current
CHSPULTRA
N/A
N/A
N/A
IG250LA, IG251
N/A
120/240 Vac, ac, Tel, Coax, 40 kA Surge Current
CHSPCHSR4P
SDSB1175C, SDSB1175DP
N/A
N/A
51120-PTC, 51110-PTC
N/A
N/A
SurgeTel, 4 Telephone Lines
DHW4PT
N/A
SurgePro THSATEL140
N/A
5350-TLL
N/A
N/A
SurgeCable, 2 Cable/Satellite Lines
DCXCAB2
N/A
SurgePro THQLCOAX
N/A
5350-BNC
N/A
N/A
SurgeEthernet, High Speed Internet
DRJ45D30R
N/A
N/A
N/A
5360-TBT, 3861-ETH
N/A
N/A
NEMA 3R Outdoor Enclosure
CHSPN3R
N/A
N/A
N/A
N/A
N/A
N/A
3 Outlet, Wallmount, ac Only
SGXMICROAC
N/A
N/A
N/A
N/A
EG33IB
N/A
3 Outlet, Wallmount, ac, Cable
SGXMICROTV
N/A
N/A
N/A
N/A
EG33EIB
N/A
3 Outlet, Wallmount, ac, Telephone Modem
SGXMICRONET N/A
N/A
N/A
N/A
EG33TIB
N/A
7 Outlet, ac Only
SGXMAXAC
N/A
SU93940
N/A
4950 Series
EG79
PS7
7 Outlet, ac, Cable
SGXMAXTV
N/A
N/A
N/A
4950 Series
N/A
N/A
7 Outlet, ac, Telephone Modem
SGXMAXNET
N/A
SU93942, SU93944
N/A
4950 Series
EG79ASO
PS7P
8 Outlet, ac Only
SGXULTAC
N/A
N/A
SPOWERMAX8
5950 Series
N/A
N/A
8 Outlet, ac, Cable
SGXULTTV
N/A
N/A
SPOWERMAX8_C 5950 Series
EG856EALI
PS8C
8 Outlet, ac, Telephone Modem
SGXULTNET
N/A
SU93950
SPOWERMAX8_T 5950 Series
EG856TALI
PS8P
8 Outlet, ac, Cable, Telephone Modem
SGXULT3WAY
N/A
SU93916
N/A
EG858DSALI, EG858ESALI
N/A
4
Lightning Arresters
Surge Breakers
Service Entrance
Accessories
Surge Strips
CA08101001E
For more information visit: www.eaton.com
5950 Series
4-10
Advanced Residential Products Surge Protection Devices and Lightning Arresters February 2007
Cross-Reference
Cross-Reference Table 4-10. Surge Products (Continued) Description
CutlerHammer
Wiremold
Panamax
DITEK
EFI
Belkin
120/240 Vac, Single-Phase, 3-Wire
CHSA01
N/A
N/A
DTK-120/240
Titan SE 120/240
N/A
600 Vac, 3-Phase, 4-Wire
CHSA03
N/A
N/A
DTK-480 3CU
Titan SE 277/240
N/A
120/240 Vac, Type BR Circuit Breaker
BRSURGE
N/A
N/A
N/A
N/A
N/A
120/240 Vac, Type CH Circuit Breaker
CHSA
N/A
N/A
N/A
N/A
N/A
120/240 Vac, 20 kA Surge Current
CHSPMICRO
N/A
N/A
DTK-120/240HD11 Titan 40 AR
N/A
120/240 Vac, 50 kA Surge Current
CHSPMAX
JA/HA
GB13
DTK-120/240 50K
N/A
120/240 Vac, 70 kA Surge Current
CHSPULTRA
N/A
N/A
DTK-120/240HD11 OSW OmIni 80K
N/A
120/240 Vac, ac, Tel, Coax, 40 kA Surge Current
CHSPCHSR4P
N/A
N/A
DTK-SS2K-SM1
Titan 100P
N/A
SurgeTel, 4 Telephone Lines
DHW4PT
N/A
GTM0286
N/A
N/A
N/A
SurgeCable, 2 Cable/Satellite Lines
DCXCAB2
N/A
GTM3080
DTK-VSP-A2
N/A
N/A
SurgeEthernet, High Speed Internet
DRJ45D30R
N/A
GTM1010
N/A
M-TELC
N/A
Flushmount Kit
CHSPFMKIT
N/A
GPP8005
N/A
N/A
N/A
NEMA 3R Outdoor Enclosure
CHSPN3R
N/A
GPPP8004
N/A
N/A
N/A
3 Outlet, Wallmount, ac only
SGXMICROAC
N/A
M2
DTK-3FMF Series
EFI-3ES
N/A
3 Outlet, Wallmount, ac, Cable
SGXMICROTV
N/A
M2T
DTK-3CFU
N/A
N/A
3 Outlet, Wallmount, ac, Telephone Modem
SGXMICRONET
N/A
M2C
DTK-3FMF Series
W100ET
N/A
7 Outlet, ac Only
SGXMAXAC
N/A
N/A
N/A
P50ES
F5C550, F5C572
7 Outlet, ac, Cable
SGXMAXTV
N/A
N/A
N/A
N/A
N/A
7 Outlet, ac, Telephone Modem
SGXMAXNET
N/A
N/A
DTK-6TA1 Series
P50ET
F5C572-TEL, F5C572-TEL-EXT
8 Outlet, ac Only
SGXULTAC
N/A
SP8
DTK-8FF-S
P1500ES
F5C595, F5H595
8 Outlet, ac, Cable
SGXULTTV
N/A
SP8T
N/A
N/A
N/A
8 Outlet, ac, Telephone Modem
SGXULTNET
N/A
SP8C
DTK-8FF-S
P1500ET
F5C795-TEL, F5C595-TEL, F5C695-TEL, F5C895-TEL
8 Outlet, ac, Cable, Telephone Modem
SGXULT3WAY
N/A
SP8DBS
DTK-DSS
P1500ED
N/A
Lightning Arresters
4
Surge Breakers
Service Entrance Titan 65 AR
Accessories
Surge Strips
For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Transfer Switch Panels
4-11
February 2007
Product Description
Transfer Switch Panels
Features, Benefits and Functions
Emergency Generator Panels
Eaton offers two unique emergency power solutions. ■ ■
Manual transfer switches. Emergency generator panels.
4
Manual Transfer Switches All Panels are Manufactured in the USA and Meet UL 1008 Indoor Design
Product Description A Transfer Switch Panel is a device that is mounted next to the loadcenter (distribution panel) in the home or small business. The Transfer Switch Panel is used in conjunction with an emergency generator (supplied by others) and serves the purpose of turning selected circuits on and off during a power outage. The Transfer Switch Panel allows the owner to start up a generator and then restore power to critical circuits when utility power is not available. The owner designates which circuits are critical such as their refrigerator and certain lights. Sometimes called Emergency Power Panels, Emergency Generator Panels, Gen. Panels, Transfer Switches or Emergency Panels; Transfer Switch Panels provide the homeowner or small business owner with a safe and easy way to continue using electrical appliances when the utility power is unavailable.
Indoor Design
Outdoor Design ■ ■ ■ ■
Indoor/Outdoor Design ■ ■
Application Description Transfer Switch Panels are most often used in residential, agricultural and light commercial applications. Comfort and safety are key concerns of many homeowners who are dependent on an uninterrupted supply of electricity. The increase in our dependence on power is due in part to the popularity of home offices and in-home health care. Various heavily populated regions of the United States experience periodic power outages due to extreme weather conditions such as ice and snowstorms, heat waves, tornadoes or hurricanes. These regions which include the Pacific Northwest, Atlantic Coast and the Gulf Coast are the strongest markets for portable generators and Transfer Switch Panels.
CA08101001E
■ ■ ■ ■
■
Panel and components sold separately. Hardwired generator connection. Ideal for new construction/larger loads. Sturdy copper bus construction. Types (CH and CHNT) breakers are sold separately. Mechanically interlocked main disconnects to prevent paralleling of normal and emergency power source. Indoor and outdoor designs offered.
■
■
Panel and components sold separately. Plug-in generator connection. All circuit breakers are included — switching duty rated. Includes dual wattmeters for load balancing. Mechanically interlocked main disconnects prevent paralleling of normal and emergency power source. Indoor and outdoor designs offered.
Standards and Certifications ■ ■
UL 67 listed. UL 1008 listed.
Product Specifications ■
10,000 AIC rating. Switching devices must be circuit breakers. ■ Transfer switch panel must be supplied with neutral and ground. ■ Power inlet box must include a circuit breaker for generator protection. ■
For more information visit: www.eaton.com
Advanced Residential Products Transfer Switch Panels
4-12
February 2007
Technical Data and Specifications
Technical Data and Specifications Table 4-11. Manual Transfer Switch
4
Table 4-12. Emergency Generator Panel
Enclosure Dimensions in Inches (mm) Type Height Width
Depth
NEMA 1 16.75 (425.5) NEMA 3R 13.00 (330.2)
3.88 (98.5) 3.56 (90.4)
14.31 (363.5) 11.00 (279.4)
Weight Lbs. (kg)
Enclosure Dimensions in Inches (mm) Type Height Width Depth
Weight – Lbs. (kg)
25 (11) 14 (6)
NEMA 1 13.23 (336.0) 11.41 (289.8) 4.10 (104.1) 24 (11) NEMA 3R 17.12 (434.8) 9.45 (240.0) 7.16 (181.9) 29 (13)
6 Circuit 10 Circuit 26 (12) 31 (14)
Installation Diagrams Utility Power Feed
Emergency Generator Panel
Cutler-Hammer Emergency Power Panel/ Manual Transfer Switch Power Inlet Box* Power Cord*
Utility Power Feed
Power Inlet Box*
Existing Main Power Panel
Power Cord*
Existing Main Power Panel (Loadcenter)
(Loadcenter)
2-Pole, 60 Amp Breaker* to Feed the Emergency Generator Panel From Your Existing Main Power Panel (Loadcenter)
2-Pole, 60 Amp Breaker* to Feed the Emergency Power Panel From Your Existing Main Power Panel Generator*
Hardwired Electrical Connection*
(Loadcenter)
Generator* * Not Included
Figure 4-3. Manual Transfer Switches — Indoor Installation Diagram
Cutler-Hammer Emergency Power Panel/ Manual Transfer Switch
2-Pole, 60 Amp Breaker* to Feed the Emergency Generator Panel From Your Existing Main Power Panel
Existing Main Power Panel
Power Cord*
Prewired Connector for Faster Installation - Included
* Not Included
Figure 4-5. Emergency Generator Panels — Indoor Installation Diagram
Utility Power Feed
Power Inlet Box*
Electrical Wiring or Power Cord*
Emergency Generator Panel
(Loadcenter)
Prewired Connector for Faster Installation Included
2-Pole, 60 Amp Breaker* to Feed the Emergency Power Panel From Your Existing Main Power Panel
Utility Power Feed
(Loadcenter)
Power Cord* Generator*
Hardwired Electrical Connection*
* Not Included
Generator* *Not Included
Figure 4-4. Manual Transfer Switches —Outdoor Installation Diagram
Figure 4-6. Emergency Generator Panels —Outdoor Installation Diagram
Warranty Manual Transfer Switch
Emergency Generator Panel
■
■
15-year loadcenter warranty. ■ Lifetime branch breaker warranty. ■ Extend the warranty to 20 years by purchasing an emergency generator panel with surge protection.
15-year loadcenter warranty. Lifetime branch breaker warranty. ■ Extend the warranty to 20 years by purchasing an emergency generator panel with surge protection. ■
For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Transfer Switch Panels
4-13
February 2007
Product Selection — Cross-Reference
Product Selection Table 4-13. Selection Enclosure Watts Number Ampere Main/Emergency Feeder Type of Circuits Rating Ampere Rating Breakers
Included Accessories
Catalog Number
Price U.S. $
Manual Transfer Switch NEMA 3R 5,000 NEMA 1 10,000
4–8 8 – 16
30 60
Provision Provision
Provision Provision
None None
CH48GEN3060R CH816GEN6060
4
Emergency Generator Panel NEMA 1 NEMA 3R NEMA 1 NEMA 3R
5,000 5,000 5,000 5,000
6 6 6 6
20 20 20 20
60/20 60/20 60/20 60/20
5 – 1P 15 1 – 1P 20 5 – 1P 15 1 – 1P 20 5 – 1P 15 1 – 1P 20 5 – 1P 15 1 – 1P 20
None None 2-Pole Surge Protector 2-Pole Surge Protector
CH6EGEN2060 CH6EGEN2060R CH6EGEN2060SUR CH6EGEN2060RSU
NEMA 1 NEMA 3R NEMA 1 NEMA 3R
7,500 7,500 7,500 7,500
10 10 10 10
30 30 30 30
60/30 60/30 60/30 60/30
6 – 1P 15 2 – 1P 20 1 2P 30 6 – 1P 15 2 – 1P 20 1 2P 30 7 – 1P 15 2 – 1P 20 1 2P 30 7 – 1P 15 2 – 1P 20 1 2P 30
None None 2-Pole Surge Protector 2-Pole Surge Protector
CH10EGEN3060 CH10EGEN3060R CH10EGEN3060SUR CH10EGEN3060RSU
Table 4-14. Accessories Description
Ampere Rating
Catalog Number
Price U.S. $
Flush Flange Kit (for use with Emergency Generator Panel Only) 10-Foot (3.05 m) Power Cord 10-Foot (3.05 m) Power Cord
— 20 30
CHEGENFKIT CH6EGEN10CORD CH10EGEN10CORD
25-Foot (7.62 m) Power Cord 25-Foot (7.62 m) Power Cord
20 30
CH6EGEN25CORD CH10EGEN25CORD
Power Inlet Box Power Inlet Box
20 30
CH6EGENPIB CH10EGENPIB
Cross-Reference Table 4-15. Cross-Reference Watts
5000 10,000 5000
Ampere Rating
Catalog Number Coleman
Gen/Tran
EmerGen
Square D
Generac
Cutler-Hammer Catalog Number
4–8 8 – 16 6
30 60 20
— — —
— — 20216
— — 6-5000
QO48M30DSGP QO48M60DSGP —
— — —
CH48GEN3060R CH816GEN6060 CH6EGEN2060
6 6 6
20 20 20
— — —
R20216 — —
6-5000 + RTE657 — —
— — —
— — —
CH6EGEN2060R CH6EGEN2060SUR CH6EGEN2060RSU
7500 10 7500 10 7500 10
30 30 30
PA0650080 — —
302110-20 R30211-20 —
10-7500 — 10-7500 + RTE1075 — — —
— — —
CH10EGEN3060 CH10EGEN3060R CH10EGEN3060SUR
7500 10 5000 6 7500 10 5000 6
30 20 30 30
— — — —
— — TRC0603A —
— — — —
— — 1276-1 —
CH10EGEN3060RSU — — —
5000 5000 5000
Number of Circuits
— — QO48M30DFGPW1 —
Gen/Trans device is not supplied with a power cord. Gen/Trans device is 12,500 maximum watts with 100 ampere utility feed. Device is not supplied with a power cord. Generac device is 7200 maximum watts on 6-circuit device and 12,000 maximum watts on 10-circuit device.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
Advanced Residential Products Portable Generators
4-14
February 2007
Product Description
Model 1653CH
Model 1654CH
Model 1894CH
4 Model 1653CH
Model 30241
Product Description
Product Description
The Model 1653CH portable generator has the basic power to run power tools or essential items during a power outage. Includes a 6.5 hp Briggs & Stratton GenPower OHV engine for long engine life, better fuel efficiency and quiet operation.
The Model 1654CH heavy-duty generator is dependable, with enough power to run several tools or appliances. Includes a 10 hp Briggs & Stratton GenPower OHV engine for long engine life, better fuel efficiency and quiet operation. Low oil protection helps prevent engine damage. Includes a fuel gauge to help track fuel levels and a Long distance Runner fuel tank which provides up to 13 hours of run time from a 7 gallon tank of fuel.
Multiple Outlet Options ■
Two 120 volt, 20 ampere standard household outlets. ■ One 120/240 volt, 30 ampere locking outlet. ■ Circuit breakers protect generator circuits from overload.
Features, Benefits and Functions 3250 Rated Watts Portable Generator ■ ■ ■ ■ ■ ■
3250 rated watts. 4550 surge watts. 6.5 hp Briggs & Stratton GenPower OHV engine. Up to 3 hours run time. 2-year limited warranty. Quiet spark arrest muffler reduces noise.
Options and Accessories (Included)
Multiple Outlet Options ■
Four 120 volt, 20 ampere standard household outlets. ■ One 120/240 volt, 30 ampere locking outlet. ■ Circuit breakers protect generator circuits from overload.
Features, Benefits and Functions 5550 Rated Watts Portable Generator ■ ■ ■ ■ ■ ■ ■
■
Engine oil. ■ Owner’s manual.
■
Product Selection Table 4-16. Product Selection Catalog Number 1653CH 1654CH 1894CH
Price U.S. $
■
5500 rated watts. 8500 surge watts. 10 hp Briggs & Stratton GenPower OHV engine. Up to 13 hours run time. 2-year limited warranty. High impact outlet cover protects outlets. Power Surge alternator has extra storage wattage for starting multiple motors. Super Silencer spark arrest muffler for quiet operation. Pneumatic wheels for all terrain mobility.
Options and Accessories (Included) ■
Wheel kit. One locking-type plug. ■ Engine oil. ■ Owner’s manual. ■
For more information visit: www.eaton.com
Model 1894CH
Product Description The Model 1894CH heavy-duty generator is dependable enough for home standby power. When it is not in use as backup power, this unit can be used for power tool applications. Includes a 15 hp Briggs & Stratton OHV Engine. Has full pressure lubrication to ensure long engine life. Also, the pressurized low oil shutdown system will shut down the engine if oil pressure drops too low. Electric start engine makes getting back-up power easy and the Ultra-Quiet spark arrest muffler offers quiet operation.
Multiple Outlet Options ■
Four 120 volt, 20 ampere standard household outlets. ■ One 120/240 volt, 30 ampere locking outlet. ■ One 12 volt dc outlet for battery charging. ■ Circuit breakers protect generator circuits from overload.
Features, Benefits and Functions 7000 Rated Watts Portable Generator ■ ■ ■ ■ ■ ■ ■ ■ ■
■
7000 rated watts. 12,250 surge watts. 15 hp Briggs & Stratton GenPower OHV engine. Up to 8 hours run time. Pneumatic tires for all-terrain mobility. Battery charging capabilities. Lo-Tone muffler — keeps noise levels to a minimum. Pushbutton electric start. PowerSurge Alternator has extra storage wattage for starting multiple motors. Weather protected control panel.
Options and Accessories (Included) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
Advanced Residential Products Standby Generator Systems
4-15
February 2007
Product Description
Standby Generator Systems
Portable generator systems are primarily used for smaller homes or for construction sites where temporary power is required. Permanently installed systems are designed for larger homes, small businesses or secondary residences such as vacation
homes, cabins, etc., that require uninterrupted power for critical loads. Eaton highly recommend, that any generator system be installed by a qualified electrician and/or generator installer.
4
Application Description 10 kW, 12 kW
All systems allow the user to pre-select critical circuits that will need power during an outage as shown in Table 4-17. When selecting the essential circuits that will be switched to “Backup Power,” it is important that the sum of the combined circuit loads does not exceed the wattage/ amperage capacity of the generator. To help you with your selection of essential circuits, please add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator’s wattage capacity. Table 4-17. Circuit Selection
7 kW
Product Description A standby generator system is a package of equipment specifically designed to provide substitute electrical power to a residence in the event of a utility power outage or other emergency. These systems are comprised of a generator, transfer switch, and the connections necessary for installation. The co-branded Briggs & Stratton Power Products/Eaton’s Cutler-Hammer systems are available in three ratings: 7000 W, 10,000 W and 12,000 W. A stand-by generator system consists of a permanently installed 7,000, 10,000 or 12,000 watt generator, hardwired to either a 50 ampere, 10-circuit sub-panel, or a 100 or 200 ampere Cutler-Hammer whole house automatic transfer switch.
Device
Running Watts
Device
Air Conditioner (12,000 Btu)
1700
Hand Drill
Air Conditioner (24,000 Btu)
3800
Iron
Air Conditioner (40,000 Btu)
6000
Jet Pump
800
Battery Charger (20 Amp)
500
Light Bulb
100
Circular Saw (6-1/2-inch)
800 – 1000
Microwave Oven
Clothes Dryer (Electric) Clothes Dryer (Gas)
5750
Milk Cooler
Running Watts 250 – 1100 1200
700 – 1000 1100
700
Oil Burner on Furnace
300
Clothes Washer
1150
Oil Fired Space Heater (140,000 Btu)
400
Coffee Maker
1750
Oil Fired Space Heater (30,000 Btu)
150
Compressor (1 hp)
2000
Oil Fired Space Heater (85,000 Btu)
225
Compressor (1/2 hp)
1400
Radio
Compressor (3/4 hp)
1800
Refrigerator
Curling Iron
700
Slow Cooker
Dehumidifier
650
Submersible Pump (1 hp)
Electric Blanket
400
Electric Range (per element)
1500
Electric Skillet
1250
Freezer
50 – 200 700 200 2000
Submersible Pump (1/2 hp)
1500
Submersible Pump (1-1/2 hp)
2800
Sump Pump
700
Table Saw (10-inch)
Furnace Fan (3/5 hp)
875
Television
Garage Door Opener
500 – 750
Toaster
800 – 1050 1750 – 2000
Standby Generator Systems are most often used in residential, agricultural and light commercial applications. Comfort and safety are key concerns of many homeowners who are dependent on an uninterrupted supply of electricity.
Notes:
The increase in our dependence on power is due in part to the popularity of home offices and in-home health care. Many regions of the United States experience periodic power outages due to extreme weather conditions such as ice and snowstorms, heat waves, tornadoes or hurricanes.
■ The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances and motors can usually be found on a data plate or decal affixed to the device. ■ If the appliance, tool or motor does not give wattage, multiply 120 volts times the ampere rating to determine watts (volts x amps = watts). ■ Some electric motors (induction types) require about three times more watts of power for starting than for running. This surge lasts for only a few seconds. Be sure you allow for this high starting wattage when selecting electrical devices that will be energized by the backup power system: ❑ Figure the watts required to start the largest motor. ❑ Add that to the total running watts of all other connected loads.
CA08101001E
Hair Dryer
200 – 500 1000 – 1650
1200
For more information visit: www.eaton.com
Advanced Residential Products Standby Generator Systems
4-16
February 2007
Features, Benefits and Functions ■
Features, Benefits and Functions Eaton’s Cutler-Hammer generator systems offer a wide range of features. All systems feature:
4
■
Powerful, reliable Briggs & Stratton, Ford or Isuzu engines. ■ Reliable Cutler-Hammer transfer switches and control systems using switching duty rated circuit breakers. ■ Transfer switches are mechanically interlocked to prevent paralleling of normal and emergency power sources.
Automatic Transfer system features automatic start/stop and provision for using propane or natural gas. Vangard OHV V-Twin engine. Diagnostic panel with remote system status. Weekly exercise function. Automatic battery charger. Run-time meter. Four sound absorbing, weatherprotected panels. CSA, cUL and UL 2200 listed and approved. Briggs & Stratton ELS OHV engine.
■ ■ ■ ■ ■ ■ ■ ■
Standards and Certifications ■
All transfer switches are UL 67 and UL 1008 listed as “Transfer Switches.” ■ All generators are UL 2200 listed.
Product Selection Table 4-18. Home Standby Selection Chart Description
Catalog Number CHGEN7000
CHGEN10000
CHGEN12000
CHGEN15000
10,000 9,000
12,000 11,000
15,000 13,500 125/62.5 112.5/56.3
Price U.S. $
Running Watts: Liquid Propane Natural Gas
7,000 6,000
Rated Amps: Liquid Propane Natural Gas
58.3/29.2 50/25
83.4/41.6 75/37.5
100/50 83.4/41.6
Starting Watts: Liquid Propane Natural Gas
10,500 9,000
12,500 11,250
15,000 13,750
Operation
Fully Automatic
Fully Automatic
Fully Automatic
Run Time
Continuous-base on Fuel Supply
Continuous-base on Fuel Supply
Continuous-base on Fuel Supply
Engine Brand
Briggs & Stratton
Briggs & Stratton
Briggs & Stratton
Engine
540cc ELS
570cc Vanguard
627cc Vanguard
Briggs & Stratton
Engine Type
OHV
OHV V-Twin
OHV V-Twin
Fuel Natural Gas : 1/2 Load Full Load
80 137
84 162
102 195
OHV V-Twin
Fuel LP Vapor : 1/2 Load Full Load
33 56
34.19 65.81
41.03 78.63
RPM
3600
3600
3600
Engine Cooling
Air
Air
Air
Air
Sound Rating
77 dB
70 dB
69 dB
65 dB
3600
System Exerciser
Every 7 Days
Every 7 Days
Every 7 Days
Remote Status
Yes
Yes
Yes
Diagnostic Alerts
4 Functions
7 Functions
7 Functions
Dimensions in Inches (mm)
31.00 x 22.00 x 33.00 (787.4 x 558.8 x 838.2)
40.00 x 22.00 x 23.00 (1016.0 x 558.8 x 584.2)
40.00 x 22.00 x 23.00 (1016.0 x 558.8 x 584.2)
Weight
280 Lbs.
379 Lbs.
384 Lbs.
400
Warranty
2 Years
3 Years
3 Years
4 Years
40.00 x 22.00 x 23.00 (1016.0 x 558.8 x 584.2)
Natural gas is in cubic feet per hour. Liquid propane vapor is in feet per hour.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Standby Generator Systems
4-17
February 2007
Technical Data Table 4-18. Home Standby Selection Chart (Continued) Description
Catalog Number CHGEN100001
CHGEN150001
CHGEN175001
CHGEN250001
Price U.S. $
Running Watts: Liquid Propane Natural Gas
10,000 10,000
15,000 15,000
17,500 17,500
25,000 25,000
Rated Amps: Liquid Propane Natural Gas
83.3/41.7 83.3/41.7
125/62.5 125/62.5
145.8/72.9 145.8/72.9
208.3/104.2 208.3/104.2
Isuzu
Isuzu
Isuzu
Isuzu
In-line 4
In-line 4
In-line 4
In-line 4
RPM
1,800
1,800
3,600
3,600
Engine Cooling
Liquid
Liquid
Liquid
Liquid
Sound Rating
76 dB
76 dB
87 dB
88 dB
53.00 x 28.00 x 47.00 (1346.2 x 711.2 x 1194.0)
53.00 x 28.00 x 47.00 (1346.2 x 711.2 x 1194.0)
53.00 x 28.00 x 47.00 (1346.2 x 711.2 x 1194.0)
53.00 x 28.00 x 47.00 (1346.2 x 711.2 x 1194.0)
Starting Watts: Liquid Propane Natural Gas Operation Run Time Engine Brand Engine Engine Type Fuel Natural Gas : 1/2 Load Full Load Fuel LP Vapor : 1/2 Load Full Load
System Exerciser Remote Status Diagnostic Alerts Dimensions in Inches (mm) Weight
961 Lbs.
994 Lbs.
950 Lbs.
994 Lbs.
Warranty
1 Year
1 Year
1 Year
1 Year
Natural gas is in cubic feet per hour. Liquid propane vapor is in feet per hour.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
4
Advanced Residential Products Standby Generator Systems
4-18
February 2007
Technical Data Table 4-18. Home Standby Selection Chart (Continued) Description
Catalog Number CHGEN20000
CHGEN25000
CHGEN30000
CHGEN35000
Price U.S. $
4
Running Watts: Liquid Propane Natural Gas
20,000 20,000
25,000 22,500
30,000 30,000
35,000 35,000
Rated Amps: Liquid Propane Natural Gas
166.7/83.3 166.7/83.3
208.3/104.2 188/94
250/125 250/1256
291.7/145.8 291.7/145.8
Ford
Ford
Ford
Ford
In-line 4
In-line 4
V-6
V-6
RPM
1,800
1,800
1,800
1,800
Engine Cooling
Liquid
Liquid
Liquid
Liquid
Sound Rating
79 dB
81 dB
79 dB
79 dB
61.00 x 28.00 x 48.00 (1,549.4 x 711.2 x 1,219.2)
61.00 x 28.00 x 48.00 (1,549.4 x 711.2 x 1,219.2)
85.00 x 35.00 x 61.00 (2,159.0 x 889.0 x 1,549.4)
85.00 x 35.00 x 61.00 (2,159.0 x 889.0 x 1,549.4)
Starting Watts: Liquid Propane Natural Gas Operation Run Time Engine Brand Engine Engine Type Fuel Natural Gas : 1/2 Load Full Load Fuel LP Vapor : 1/2 Load Full Load
System Exerciser Remote Status Diagnostic Alerts Dimensions in Inches (mm) Weight
1,190 Lbs.
1,219 Lbs.
2,042 Lbs.
2,042 Lbs.
Warranty
1 Year
1 Year
1 Year
1 Year
Natural gas is in cubic feet per hour. Liquid propane vapor is in feet per hour.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Standby Generator Systems
4-19
February 2007
Technical Data Table 4-18. Home Standby Selection Chart (Continued) Description
Catalog Number CHGEN45000
CHGEN55000
CHGEN7500
Price U.S. $
Running Watts: Liquid Propane Natural Gas
45,000 42,000
55,000 55,000
75,000 70,000
Rated Amps: Liquid Propane Natural Gas
375/187.5 354/177
458.3/229.2 458.3/229.2
625/312.5 583/292
Ford
Ford
Ford
V-6
V-10
V-10
RPM
1,800
1,800
1,800
Engine Cooling
Liquid
Liquid
Liquid
Sound Rating
80 dB
85 dB
85 dB
Dimensions in Inches (mm)
85.00 x 35.00 x 61.00 (2,159.0 x 889.0 x 1,549.4)
95.00 x 36.00 x 61.00 (2,413.0 x 914.4 x 1,549.4)
95.00 x 36.00 x 61.00 (2,413.0 x 914.4 x 1,549.4)
Weight
2,152 Lbs.
2,586 Lbs.
2,696 Lbs.
Warranty
1 Year
1 Year
1 Year
Starting Watts: Liquid Propane Natural Gas Operation Run Time Engine Brand Engine Engine Type Fuel Natural Gas : 1/2 Load Full Load Fuel LP Vapor : 1/2 Load Full Load
System Exerciser Remote Status Diagnostic Alerts
Natural gas is in cubic feet per hour. Liquid propane vapor is in feet per hour.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
4
4-20
Advanced Residential Products Standby Generator Systems February 2007
Technical Data and Specifications — Product Selection
Automatic Transfer Switches 50, 100 and 200 Ampere
Meter Standby Generator
50 Ampere Indoor Transfer Switch
Sound Shield
4
100/200 Ampere Service Panel
Fuel Supply (NG or LP)
50 Ampere Indoor /Outdoor
Air Conditioner
Figure 4-7. 50 Ampere — Indoor Installation — Selected Load Pre-Wired
Standby Generator
Service Disconnect
Meter
100/200 Ampere Outdoor Transfer Switch
100 Ampere Outdoor & 200 Ampere Outdoor
Fully Automatic All of our switches monitor utility and generator voltages and will automatically connect to the appropriate source of power. 100 and 200 ampere switches are capable of ‘whole house’ power transfer in residential/small business applications.
Low Voltage Disconnect
Sound Shield
100/200 Ampere Service Panel
Fuel Supply (NG or LP)
Air Conditioner
Figure 4-8. 100/200 Ampere — Outdoor Installation — Whole House Pre-Wired
Technical Data and Specifications Table 4-19. Selection Chart Specifications or Dimensions
Catalog Number CHGEN50ATS
CHGEN50ATSR
CHGEN100ATSR
CHGEN100ATSRSE
CHGEN200ATSR
CHGEN200ATSRSE
Voltage Circuits Amperes Poles
120/240 10 50 2
120/240 10 50 2
120/240 Whole House 100 2
120/240 Whole House 100 2
120/240 Whole House 200 2
120/240 Whole House 200 2
Frequency UL Listed Withstand Rating Switch Type
50/60 1008 5,000 Relay
50/60 1008 5,000 Relay
50/60 1008 22,000 Mechanically Held
50/60 1008 22,000 Mechanically Held
50/60 1008 25,000 Mechanically Held
50/60 1008 25,000 Mechanically Held
Enclosure Engine Warm-Up
NEMA 1 (indoor) 20/50 seconds
NEMA 3R (outdoor) 20/50 seconds
NEMA 3R (outdoor) 10 seconds
NEMA 3R (outdoor) 10 seconds
NEMA 3R (outdoor) 10 seconds
NEMA 3R (outdoor) 10 seconds
Depth Width Height Weight
4 inches 14.25 inches 21 inches 25 lbs.
4 inches 14.25 inches 21 inches 25 lbs.
5 inches 11 inches 17 inches 26 lbs.
5 inches 14 inches 29 inches 35 lbs.
5 inches 14 inches 29 inches 35 lbs.
5 inches 14 inches 34 inches 45 lbs.
Product Selection Table 4-20. Price List Catalog Number
Price U.S. $
CHGEN50ATS CHGEN50ATSR CHGEN100ATSR CHGEN200ATSR CHGEN100ATRSE CHGEN200ATRSE
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products StructuredWiringSolutions
February 2007
4-21
Product Description
StructuredWiringSolutions
Application Description Structured wiring is typically installed in the following areas:
Features, Benefits and Functions ■
■
Pre-wiring in new construction. ■ Installations in single-unit homes vs. wiring multi-dwelling units. ■ Marketing and installation in production built homes vs. custombuilt homes.
■ ■ ■
Structured Wiring BR00412001E
A system is composed of the following: ■
Product Description Structured wiring is a simple, affordable way to wire a home for state-of-the-art communications, entertainment, and security now and for many years to come. The basic concept is that all telephone, television, satellite, coaxial, audio and data communications cables are wired in a star topology (home run) to each room in the home and terminate at a central distribution panel. This distribution panel allows flexibility for future modifications and/or additions to keep pace with a homeowner’s lifestyle and needs. Structured wiring can also be used as a central hub to interconnect a security system, home automation, HVAC and load control providing a complete system to increase the security, comfort and convenience for a homeowner. Today, the demand for structured wiring is high due to the impact of the Internet and multi-media applications. Ultimately, people will need a home local area network (LAN) to accommodate peripheral devices throughout the home. All indication is that the impact of the Internet and coming of broadband will drive over 80% of structured wiring installations.
A distribution panel is used to distribute outside services like cable TV, telephone, DBS satellite, Internet and the like, to locations throughout the home. ■ Certain services like digital cable, digital satellite, high-speed Internet and HDTV require the second part of the wiring system, high-performance cables, to allow full access throughout the home. ❑ RG-6 coaxial cable for TV and video distribution ❑ Category 5 – telephone and data ■
Each room has a multimedia outlet, which can be customized to users’ specific needs based on what services they want in each room.
Typical Applications Internet Access, Telephone and Fax All at the Same Time ■
Connect multiple computers, faxes and telephones so they work together, yet separately. ■ Access to DSL or cable modem in every room.
Take Home Theater Beyond the TV Room ■ ■
In-house audio distribution. DBS or cable access from any room.
Have 24-Hour Peace of Mind ■
Know your family is safe even if you are not there. ■ Video monitoring, front door surveillance.
Be in Control ■
Connect to a variety of home automation products to control indoor and outdoor lighting, heating/cooling and security systems.
Count on Technology ■
CA08101001E
Anytime you need to add.
For more information visit: www.eaton.com
■ ■ ■ ■ ■ ■ ■ ■
■ ■
Meets UL standards — communication circuit accessory. Consumer friendly factoryassembled packages. Accepts CAT5e, RG-6 and optional Fiber Optic wiring. Compact low profile enclosures complete with 1/2-inch (12.7 mm) sheet rock spacers and 110 volt power outlets. Combination telephone and coaxial modules. Connections to interface to a Key System Unit (KSU) or PBX systems. Built-in surge suppression and 20dB bi-directional amplifier. Built-in security RJ31X interface port. 10/100Base-T Ethernet. 10/100 auto switching cable/DSL firewall Internet router. Satellite DBS distribution. Wide range of accessories, including patch cords, telephone line breakout, CAT5e and RG6 inserts. Whole house audio distribution. Patented patch bay design to simplify routing and rerouting signals.
Standards and Certifications UL listed 64EK as Communication Circuit Accessory.
4
4-22
Advanced Residential Products StructuredWiringSolutions February 2007
Product Selection
Product Selection Table 4-21. StructuredWiringSolutions — Dimensions in Inches (mm) Packages
4
Dimensions
Mounting
Shipping Weight Lbs. (kg)
Color
Basic Communication Package — basic video and voice distribution
14.5-inch W 18-inch H 4-inch D (368.3 W 457.2 H 101.6 D)
Mounts between 16-inch (406.4) OC studs
16.00 (7.2)
White 4 populated zones (8-CAT5e and 8-RG6 connections)
4 lines to 8 locations (RJ45 with RJ31X for a security system)
Entertainment Upgrade Package — flexible and economical distribution panel that offers amplification and surge protection for coax distribution
14.5-inch W 18-inch H 4-inch D (368.3 W 457.2 H 101.6 D)
Mounts between 16-inch (406.4) OC studs
21.00 (9.5)
White 4 populated zones (8-CAT5e and 8-RG6 connections)
4 lines to 8 locations (RJ45 with RJ31X for a security system)
Education and Home Office Upgrade Package — the ideal package for learning and/or working from home. Patented patch bay design to provide unparalleled ease-of-use when routing or rerouting signals for voice, video and Internet security for homes and small offices
14.5-inch W 36-inch H 4-inch D (368.3 W 914.4 H 101.6 D)
Mounts between 16-inch (406.4) OC studs
34.00 (15.4)
White 6 populated zones (12-CAT5e and 12-RG6 connections, 6-CAT5e patch cords, 6-RG6 coax patch cords, 6-Quad shield)
4 lines to 12 locations (RJ45 with RJ31X for a security system) ■ Surge suppression ■ PBX/KSU connection
Whole-House Audio Package — economically and conveniently distribute high quality sound throughout the home
1 — 8 location audio distribution module 125 watts per channel, up to 8 pairs of 16 AWG, impedance matched for load protection.
Zones
Telephone Distribution
3 — 75-watt volume controls ■ 10 position, 75-watt continuous, plastic decor.
For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products StructuredWiringSolutions
4-23
February 2007
Product Selection Table 4-21. StructuredWiringSolutions (Continued) Coax Distribution
Ethernet Distribution/ Internet Router
Future Expansion Bays
Capacity
Electrical
Catalog Number
1 input, 8 outputs with 2 pass-through connections for DBS satellite — non-amplified
Available (see products and accessories)
4
Services up to 8 telephone locations and 8 non-amplified TV locations
110 Volt power outlet
CHSWPAK1
Price U.S. $
4
5 inputs, 8 outputs with 4 pass-through connections for DBS satellite (1 input for TV/ CATV; 4 inputs for modulated CCTV, DVD, VCR or SATV signals) ■ 20 dB bi-directional amplifier. ■ Surge suppression.
Available (see products and accessories)
2
Services up to 8 telephone locations and 8 amplified TV locations
110 Volt power outlet
CHSWPAK2
5 inputs, 8 outputs with 2 pass-through connections for DBS satellite (1 input for TV/ CATV; 4 inputs for modulated CCTV, DVD, VCR or SATV signals) ■ 20 dB bi-directional amplifier. ■ Surge suppression.
Internet Router 4 port, 10/100 auto switching cable/DSL firewall Internet router ■ Dynamic host configuration protocol (DHCP) for LAN configurations. ■ Network address translation (NAT) firewall protection. ■ Key word content filtering and logging. ■ User friendly, Web-based setup wizard.
3
Services up to 6 zones with 2-CAT5e, 2-RG6 and Internet connection
110 Volt power outlet
CHSWPAK4
CHAUDPAK
3 — 1 pair set of 100-watt ceiling mount speakers ■ 2-way indoor, coaxial, flush mounted, 6.5-inch (165.1 mm) polypropylene, 0.75-inch (19.1 mm)
dome swivel, micromesh,12 dB octave crossover, 65 Hz to 20,000 kHz.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
4-24
Advanced Residential Products StructuredWiringSolutions February 2007
Product Selection
Products and Accessories Whether you choose to personally design StructuredWiringSolutions or if you would like to stock various component packages, the following products and accessories will help you find what you are looking for easily. Table 4-22. Products and Accessories Product Description
Shipping Weight Lbs. (kg)
Catalog Number
QuickNetwork 18-inch (457.2) — Install Can with 110 volt Power and Cover (Metal) QuickNetwork 24-inch (609.6) — Install Can with 110 volt Power and Cover (Metal) QuickNetwork 36-inch (914.4) — Install Can with 110 volt Power and Cover (Metal) QuickNetwork 48-inch (1219.2) — Install Can with 110 volt Power and Cover (Metal)
12 (5.45) 15 (6.81) 20 (9.08) 22 (10.00)
CHQN18 CHQN24 CHQN36 CHQN48
QuickNetwork 18-inch (457.2) — Install Can with 110 volt Power (Metal) QuickNetwork 24-inch (609.6) — Install Can with 110 volt Power (Metal) QuickNetwork 36-inch (914.4) — Install Can with 110 volt Power (Metal) QuickNetwork 48-inch (1219.2) — Install Can with 110 volt Power (Metal)
12 (5.45) 15 (6.81) 20 (9.08) 22 (10.00)
CHQNIC18 CHQNIC24 CHQNIC36 CHQNIC48
QuickNetwork Cover for QNIC18 (Clear Plastic) QuickNetwork Cover for QNIC24 (Clear Plastic) QuickNetwork Cover for QNIC36 (Clear Plastic) QuickNetwork Cover for QNIC48 (Clear Plastic)
7 (3.18) 8 (3.63) 10 (4.54) 14 (6.36)
CHQNCC18C CHQNCC24C CHQNCC36C CHQNCC48C
QuickNetwork Cover for QNIC18 (Metal) QuickNetwork Cover for QNIC24 (Metal) QuickNetwork Cover for QNIC36 (Metal) QuickNetwork Cover for QNIC48 (Metal)
7 (3.18) 8 (3.63) 10 (4.54) 14 (6.36)
CHQNCC18 CHQNCC24 CHQNCC36 CHQNCC48
Locking cover for CHSP08 or CHSP08R Distribution Panel Locking cover for CHSP16 or CHSP16R Distribution Panel Locking cover for CHSP24, CHSP24R, CHSP32, or CHSP32R Panel
6 (2.72) 9 (4.09) 11 (5.00)
CHCVSP08 CHCVSP16 CHCV24/32
4
Price U.S. $
Distribution Panels
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products StructuredWiringSolutions
4-25
February 2007
Product Selection Table 4-22. Products and Accessories (Continued) Product Description
Shipping Weight Lbs. (kg)
Catalog Number
Price U.S. $
Modules for QuickNetwork Series Panels 12 Port, 4 Line Telephone Module 2.5 (1.13) Twelve RJ45 ports (CAT5 rated) support four incoming phone lines with speeds up to 100 Mbps. Includes two Amphenol connectors for interface to a Key System Unit (KSU) or PBX. The Amphenol connectors include a shorting block for compatibility with Plain Old Telephone (POTS) lines. Includes surge suppression and one RJ31X port. 12-inch (304.8) form factor.
CHMDT124P
12 Port, 4 Line Punchdown Telephone Module 1 (0.45) The 12/4 Punchdown Telephone Module has twelve laceways which support four (4) incoming telephone lines and distribution to up to 12 locations. 6-inch (152.4) form factor.
CHMDT124HB
12 Port, 2 Line Telephone Module 1.8 (0.82) This 12 location, 2 line, RJ11 harmonica-style twisted pair module is used for connecting and distributing voice at speeds up to 10 Mbps. Includes twelve (12) RJ11 ports, supports two (2) incoming telephone lines, and includes an Amphenol connector for interface with a telephone Key System Unit (KSU) or PBX. The Amphenol connector includes a shorting block for compatibility with Plain Old Telephones (POTS) lines. Includes surge suppression. 12-inch (304.8) form factor.
CHMDT122P
8 Port, 4 Line Telephone Module 8 RJ45 ports support four (4) incoming phone lines. One RJ31X port for security. 6-inch (152.4) form factor.
1 (0.45)
CHMDT8RJ
16 Port, 4 Line Telephone Module 16 RJ45 ports support four (4) incoming phone lines. One RJ31X port for security. 6-inch (152.4) form factor.
1.25 (0.57) CHMDT16RJ
Combo 4x8 Coax/Phone Distribution Module (with 110 punchdown connectors.) Distributes 1 incoming coax TV line to 4 locations (plus 2 pass-throughs) and 4 telephone lines to 8 locations. 6-inch (152.4) form factor.
1.2 (0.54)
CHMDX48300
Combo 4x8 Coax/Phone Distribution Module (with RJ45 patch connectors.) Distributes 1 incoming coax TV line to 4 locations (plus 2 pass-throughs) and 4 telephone lines to 8 locations. Includes an RJ31X connection. 6-inch (152.4) form factor.
1.1 (0.50)
CHMDC4T8RJ
Combo 8x8 Coax/Phone Distribution Module (with 110 punchdown connectors.) Distributes 1 incoming coax TV line to 8 locations (plus 2 pass-throughs) and 4 telephone lines to 8 locations. 6-inch (152.4) form factor.
1.2 (0.54)
CHMDX88300
Combo 8x8 Coax/Phone Distribution Module (with RJ45 patch connectors.) Distributes 1 incoming coax TV line to 8 locations (plus 2 pass-throughs) and 4 telephone lines to 8 locations. Includes an RJ31X connection. 6-inch (152.4) form factor.
1.2 (0.54)
CHMDC8T8RJ
1x4 Coax Module 1 in, 4 out coax module with 4 pass-through connectors. 6-inch (152.4) form factor.
1 (0.45)
CHMDC104
1x8 Coax Module 1 in, 8 out coax module with 2 pass-through connectors. 6-inch (152.4) form factor.
1.3 (0.60)
CHMDC108
4
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
4-26
Advanced Residential Products StructuredWiringSolutions February 2007
Product Selection Table 4-22. Products and Accessories (Continued) Product Description
Shipping Weight Lbs. (kg)
Catalog Number
5x8 Coax Module 5 in, 8 out coax module with 20 dB bi-directional amplifier, surge protection, and 4 passthrough connectors, and 4 inputs for modulated signals. 12-inch (304.8) form factor.
3 (1.36)
CHMDC408
5x12 Coax Module 5 in, 12 out coax module with 20 dB bi-directional amplifier, surge protection, and 4 passthrough connectors, and 4 inputs for modulated signals. 12-inch (304.8) form factor.
3.5 (1.59)
CHMDC412
5x16 Coax Module 5 in, 16 out coax module with 20 dB bi-directional amplifier, surge protection, with 1 direct and 4 inputs for modulated signals. 12-inch (304.8) form factor.
3.6 (1.63)
CHMDC416
Blank Patch Module Twelve connection ports (2 CAT5 and 2 coax per zone). 6-inch (152.4) form factor.
0.8 (0.36)
CHMDPB
2-Zone Patch Module Twelve connection ports (2 CAT5, 2 coax, and 2 Fiber Optic connections per zone). 6-inch (152.4) form factor.
0.8 (0.36)
CHMDP2
3-Zone Patch Module Twelve connection ports (2 CAT5 and 2 coax per zone). 6-inch (152.4) form factor.
0.8 (0.36)
CHMDP3
4 Location DBS Distribution Module Provides distribution of a dual LNB DBS Digital Satellite Dish signal to 4 locations through a single coax cable without modulation. Each TV location must be connected to a separate DBS receiver where desired. 6-inch (152.4) form factor.
1.7 (0.77)
CHMDDS4
8 Location Audio Distribution Module The Audio Distribution Module allows an audio signal to be distributed to 8 stereo or 16 mono speaker locations. 6-inch (152.4) form factor.
1.0 (0.45)
CHMDAD86
Triple Channel Modulator Module Used for creating in-home television channels for viewing from any TV in the home. Signals from 3 different audio/video sources such as TV, VCR, DVD, DBS, satellite TV, and security cameras may be identified and displayed by any television. 6-inch (152.4) form factor.
2.1 (0.95)
CHMDMD03
Door Station Module This module allows the homeowner to speak to visitors at a front door or entry using existing telephones. Includes one door station speaker. 6-inch (152.4) form factor.
2.1 (0.95)
CHMDFDS
Price U.S. $
Modules for QuickNetwork Series Panels (Continued)
4
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products StructuredWiringSolutions
4-27
February 2007
Product Selection Table 4-22. Products and Accessories (Continued) Product Description
Shipping Weight Lbs. (kg)
Catalog Number
8 Port, 10/100Base-T Ethernet Switch Module Used to create a Local Area Network (LAN) by connecting up to 8 computers, printers, scanner, fax machines, etc. Supports data transfer speeds up to 100 Mbps. Stackable. Bridgeable. 12-inch (304.8) form factor.
3.0 (1.36)
CHMDEN108
5 Port, 10/100Base-T Ethernet Switch Module Used to create a Local Area Network (LAN) by connecting up to 5 computers, printers, scanner, fax machines, etc. Supports data transfer speeds up to 100 Mbps. Stackable. Bridgeable. 12-inch (304.8) form factor.
3.0 (1.36)
CHMDEN105
5 Port, 10Base-T Ethernet Switch Module Used to create a Local Area Network (LAN) by connecting up to 5 computers, printers, scanner, fax machines, etc. Supports data transfer speeds up to 10 Mbps. Stackable. Bridgeable. 12-inch (304.8) form factor.
3.0 (1.36)
CHMDEN10
Web Safe Internet Router Module This web safe Internet router includes a built-in 4 port, 100 Mbps Ethernet switch, content filtering and hacker protection. 12-inch (304.8) form factor.
4.0 (1.82)
CHMDRP114
8 Location Audio Distribution Module For use in QuickNetwork panels. The Audio Distribution Module allows an audio signal to be distributed to 8 stereo or 16 mono speaker locations. 6-inch (152.4) form factor.
1.0 (0.45)
CHMDAD86
75 Watt Volume Control
2.0 (0.91)
CHAUD75VC
35 Watt Volume Control
2.0 (0.91)
CHAUD35VC
Speakers, In-Wall (set of 2) 6.5-inch (165.1) Poly Woofer, .75 (19.1) Tweeter. Surround Sound capable.
9.0 (4.09)
CHAUDW65
Speakers, In-Ceiling (set of 2) 6.5-inch (165.1) Poly Woofer, 1-inch (25.4) Swivel Tweeter. Surround Sound capable.
9.0 (4.09)
CHAUDC65
Speakers, Outdoor (set of 2) 5.5-inch (139.7) Poly Woofer, .75 (19.1) Tweeter, Black. Surround Sound capable.
9.0 (4.09)
CHAUDO55B
9.0 (4.09)
CHAUDO55W
Price U.S. $
Modules for QuickNetwork Series Panels (Continued)
4
Entertainment System Components
Speakers, Outdoor (set of 2) 5.5-inch (139.7) Poly Woofer, .75 (19.1) Tweeter, White
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
4-28
Advanced Residential Products StructuredWiringSolutions February 2007
Product Selection Table 4-22. Products and Accessories (Continued) Product Description
Shipping Weight Lbs.(kg)
Catalog Number
2 Pair, CAT3 Telephone Patch Cord, 36 inches (914.4) 2 Pair, CAT3 Telephone Patch Cord, 8 inches (203.2) 2 Pair, CAT3 Telephone Patch Cord, 24 inches (609.6)
0.1 (0.05) 0.1 (0.05) 0.1 (0.05)
CHPCT2 CHPCT21 CHPCT22
4 Pair, CAT5 Telephone Patch Cord, 36 inches (914.4) 4 Pair, CAT5 Telephone Patch Cord, 8 inches (203.2) 4 Pair, CAT5 Telephone Patch Cord, 24 inches (609.6)
0.1 (0.05) 0.1 (0.05) 0.1 (0.05)
CHPCT4 CHPCT41 CHPCT42
RG6-rated Mini Digital Cable, 8 inches (203.2) RG6-rated Mini Digital Cable, 14 inches (355.6) RG6-rated Mini Digital Cable, 24 inches (609.6) RG6-rated Mini Digital Cable, 36 inches (914.4)
0.1 (0.05) 0.1 (0.05) 0.1 (0.05) 0.1 (0.05)
CHPCCXM CHPCCXM1 CHPCCXM2 CHPCCXM3
ST Fiber Optic Patch Cord, 36 inches (914.4)
0.1 (0.05)
Price U.S. $
Patch Cords and Miscellaneous
4
CHPCFO
Single Channel Modulator 1.0 (0.45) Used for creating an in-home television channel for viewing from any TV in the home. A signal from audio/video sources such as TV, VCR, DVD, DBS, satellite TV, and security cameras may be identified and displayed by any television.
CHMOD01
Triple Channel Modulator Attach to a home entertainment center for creating an in-home television channel for viewing from any TV in the home. A single signal from audio/video sources such as TV, VCR, DVD, or satellite TV may be identified and displayed by any television. For multiroom video distribution, a separate Triple Channel Modulator (part #MDMD or HBMD) must be installed in the distribution panel.
1.0 (0.45)
CHMOD03
Telephone Line Breakout Module Connects up to 4 devices (phone, fax, DSL or cable modem, etc.) to a single CAT5 jack, with one pass-through connection.
1.0 (0.45)
CHLBO1
CAT5e Insert Jack for Distribution Panel (includes Blue Bezel, part #BZ5N.) These Category 5e twisted pair, RJ45 jacks include punch down diagrams for 568A or 568B configurations.
0.1 (0.05)
CHML5N
Coax Insert for Distribution Panels Yellow color.
0.1 (0.05)
CHMLCN
ST-Style Fiber Optic Inserts for Distribution Panels Used to populate any fiber optic-compatible FutureSmart Distribution panel. Red with red dust cap.
0.1 (0.05)
CHMLFN
CAT5 Bezel Insert for Distribution Panel connectors Blue.
0.1 (0.05)
CHBZ5N
Icon Insert for CAT5 Modules Computer/Data Icon, wheel of 16.
0.1 (0.05)
CHIIDT
Icon Insert for CAT5 Modules Telephone/Voice Icon, wheel of 16.
0.1 (0.05)
CHIITP
0.1 (0.05) 0.1 (0.05) 0.1 (0.05) 0.1 (0.05)
CHBLNW CHBLNR CHBLNY CHBLNB
—
CHPSV110
Inserts
Blank Insert for Distribution Panel — White Blank Insert for Distribution Panel — Red Blank Insert for Distribution Panel — Yellow Blank Insert for Distribution Panel — Blue
Power Supplies 110 Vac Power Supply for all Coax Hubs and Modules (CHHBC408, CHHBC412, CHHBC416, CHMDC408, CHMDC412, CHMDC416)
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products StructuredWiringSolutions
4-29
February 2007
Cross-Reference
Cross-Reference Table 4-23. Cross-Reference (Most Commonly Used Components) Cutler-Hammer Square D
CHSWPAK1
SDM18BW + SDM18CW + SDM26P14V
Pass & Seymour/ Legrand
OnQ
—
Cooper Wiring Devices
GE Smart
Open House
Home Director
Siemon Leviton Home Cabling System
1267077-01 + 5570 – DC-SY0100/ — 1267062-01 + Multi-Media DC-SY0400/ 363855-03 Manager DC-SY0425/ DC-SY0800
SP01
HC-K2-AJLN-80
Greyfox UStec
47605-BTV – — Type SMC-140
TGS200/tecReady MDU/tecLAN MDU/ iLAN400/tecReady 400/tecReady 800/ tecReady 1600/ tecLAN 400 tecLAN 800/ tecLAN 1600
CHSWPAK2
SDM18BW + — SDM18CW + SDM46P + SDM38VBIR + SDM11VMB + SDM4AC
1267077-01 + — 1267062-01 + 363468-02
DC-SY0430/ — DC-SY0825/ DC-SY0830
BL01/PL00 —
—
CHSWPAK4
SDM18BW + — SDM18CW + SDM46P + SDM38VBIR + SDM8D + SDM5DE + SDM4AC
1267077-01 + — 1267062-01 + 363855-03 + 364415-01
—
—
—
—
47605-ASO – — Type SMC-140
—
CHAUDPAK
—
—
—
—
—
—
—
—
—
—
CHQN18
SDM18BW + SDM18CW
HNE-1414 - 14 1267077-01/ + TRIM-1414 or 363474-01 HNE-1421 + TRIM-KIT Comprehensive or TRIMKIT2 Basic
—
—
H218A/ HC18A
—
HC-ENCL-10-80 10-inch Enclosure
47605-14W E-Series/ Type SMC-140 S-Series
UX75
CHQN24
—
—
364257-01/ 363475-01
—
—
—
—
HC-ENCL-2-80
47605-28W – D-Series Type SMC-280
FX-100/FX-410
CHQN36
SDM36BW + SDM36CW
(2) HNE-1421 + TRIM-42 DoubleHeight Kit
363476-01
—
—
H236A/ HC36A
NCCR01 + HC-ENCL-36-80 NCCR05 or NCCR04
47605-42W – P-Series Type SMC420
UX75 + UX100
CHMDT8RJ
SDM46P/ SDM48P/ SDM48PX
RTM-7544/ RTM-7556
363940-01/ 363941-01
5571
—
H616/H618 T01/T02/ T04/T06/ T07/T08
HC-110-80-100/ HC-110B-80-100/ HC110-JP6-80/ HC-110-JP12-80
47689-B
F7556
TPDM6R
RTM-1379/ RTM7542/ HOF-7547
—
—
—
H619
—
47605-C5B
F1475/ F7542
—
CHMDT416100 —
T05
—
—
CHMDT124P
—
—
—
—
—
H611 - 4
—
—
—
—
—
CHLBO1
—
—
364260-01
—
—
—
—
YA4-A3-U1
47609
—
—
CHML5N
—
—
364289-01
5546W
—
—
—
MX5-F(XX)
40838
—
—
CHPCT42
—
—
363201-25
5500-3GY
—
H691/H692 —
—
52455-3
—
—
CHMDC108
SDM13VS/ SDM14VS
VDM-7577/ VDM-7585/ VDM-7624
364224-01
5573
—
H838HHR/ V08 H838BID
HC-RF-8HS
47690-8C2
F7585/ F7577
CX4X4U-SI
CHMDC408
SDM16VAB/ SDM38VBIR
VDM-7583/ VDM-7621/ VDM-7623
363468-02/ 363469-02
—
—
H816BID
V02
—
47690-38B
F7621
CXAMP8
CHMDC412
—
VDM-7622/ VDM-7626
—
—
—
—
—
—
—
F7622
CAAMP16
CHMDDS4
—
—
364228-01
—
—
—
—
—
—
—
CXDM8
CHMLCN
—
—
364297-01
—
—
—
—
MX5-F(XX)
40831-BI
—
—
CHPCCXM2
—
—
—
—
—
—
—
—
—
—
—
CHMDX88300
—
—
—
—
—
—
—
—
47603-BTV
—
UX-220
CHMDC8T8RJ
SDM26P14V/ SDM46P14V
—
—
—
—
—
—
—
47603-BHN
—
—
CHMDP3
—
—
—
—
—
—
—
—
—
—
—
CHMDPB
—
—
—
—
—
—
—
—
—
—
—
CHMDEN10
SDM8D/ SDM5DE
CNS5-10100BT 364235-02/ 364411-01
—
—
H628/ E01/F01 H629/H635
—
47605-ETX/ 47605-EH
F7546
—
CHMDENR100
—
—
—
—
—
—
—
—
—
F7561
TP10-100BT
CHAUD75VC
—
AVC-W
—
—
—
—
—
—
40841-DI
—
—
CHAUDC65
—
SPK-4/SPK-65/ — SPK-8
—
—
—
—
—
40891-W
—
—
CHMDAD86
—
AVC-7537
—
—
—
A01
—
48211-6A
F7537
—
363530-01
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
4
4-30
Advanced Residential Products February 2007
This page intentionally left blank.
4
For more information visit: www.eaton.com
CA08101001E
Advanced Residential Products Arc Fault Circuit Interrupter (AFCI)
4-31
February 2007
FIRE-GUARD
FIRE-GUARD Arc Fault Circuit Interrupter (AFCI)
CH115AF
BR115AF
Product Description Eaton’s Cutler-Hammer FIRE-GUARD Arc Fault Circuit Interrupter (AFCI) is a residential circuit breaker with an integrated processor which recognizes the unique current and/or voltage signatures associated with arcing faults, and acts to interrupt the circuit to reduce the likelihood of an electrical fire. With the FIRE-GUARD AFCI, protection from arcing faults is combined with conventional thermal and magnetic overloads as found in standard residential circuit breakers protecting wiring from excessive heat or damage due to overloading or short circuits. FIRE-GUARD AFCI can also be equipped with 5 mA ground fault protection to protect from personal shock hazards. Now, there is a residential circuit breaker that provides protection from arcing faults, conductor damage due to thermal overloads and short circuits, as well as 5 mA ground fault protection in one integrated design.
CA08101001E
Application Description
Arcs in Wiring
Background
Parallel Arcs
Prior to the FIRE-GUARD AFCI, present-day residential circuit breakers were designed to protect wiring from excessive heating by opening automatically when an overload condition was present. These breakers typically contain a bimetal and magnetic trip element. During low current overloads, heating of the bimetal element causes the breaker to unlatch the contact-separation mechanism, turning power off in the affected circuit. For high overcurrent conditions, such as short circuits, the high magnetic field associated with high current flow causes the “instantaneous tripping” of the breaker mechanism. The breaker response time is a function of the circuit current and time, with faster response at higher currents. In particular, the circuit breaker Time versus Current characteristics, is selected to prevent conductor damage. Present overcurrent devices, such as circuit breakers and fuses, represent a major safety feature in today’s residences. They prevent excessive temperatures in the conductors or conductor insulation and they reduce the incidence of household fires, to a great extent, through their prevention of overheating effects. The response time of present-day circuit breakers is determined solely by the duration and magnitude of the circuit overcurrent. This response is adequate to protect the wiring if the circuit wiring integrity has been maintained. However, once this integrity has been compromised via broken wires or deteriorated insulation, electric arcs can occur. These arcs are characterized by a plasma flame which can release temperatures in excess of 6000ºC. An arcing fault can go undetected by a thermal, as well as magnetic trip element. The challenge answered by the FIRE-GUARD AFCI is to enhance circuit protection by identifying the presence of arcing faults, and responding to their presence by opening the circuit in times which are faster than standard circuit breakers. By integrating custom electronics into a present-day circuit breaker, the FIRE-GUARD meets the challenge and offers enhanced protection from household fires.
For more information visit: www.eaton.com
Electrical arcs can be placed into two categories. The most familiar and dramatic arcs in residential wiring are associated with short circuit arcs between two conductors. In a parallel arc, the load is paralleled by the arcing fault. An example would be the accidental severing of the power cord and a hedge trimmer or other power tool. A less obvious example would be the deterioration of insulation in the wiring behind a wall, due for example, to the cumulative effect of electrical surges, heat or moisture over many years. A parallel arc can often “sputter” on and off for extended periods of time without detection, increasing the risk of fire.
Series Arcs Arcs can also occur at a break in a single conductor. These series arcs are relatively low current since they are in a series with the load. In practice, it is difficult to sustain such arcs since copper-to-copper arcing is unsustainable at 125 Vac. However, such arcing can occur in the presence of carbonized insulation. The arcs are typically sputtering and intermittent in nature, and tend to alert the homeowner since they lead to intermittent device operation such as flickering lighting loads. In Figure 4-9 (Page 4-32) residential wiring has been divided into four zones. The Cutler-Hammer FIRE-GUARD AFCI will provide parallel arc detection and protection in Zones 1, 2 and 3 and it will respond to arcing to ground in all three of these zones. FIRE-GUARD AFCI responds to series arcs in two conductor plus ground fixed premises wiring (Type N-B wire) of Zone 1.
Types of AFCIs The 2005 NEC allows current AFCI products (branch/feeder AFCIs) or a 2nd type of AFCI (combination type) to be installed. The UL AFCI standard defines a combination AFCI as “meeting the requirements for both branch/feeder and outlet circuit AFCIs.”
4
Advanced Residential Products Arc Fault Circuit Interrupter (AFCI)
4-32
February 2007
FIRE-GUARD
4
As of July 2005, combination AFCIs are not available from any manufacturer. These should not be confused with the dual-listed Cutler-Hammer AFCI/GF breakers that are available today from Eaton’s electrical business. Eaton AFCIs include both ground fault and arc fault protection. The ground fault threshold is either 30 mA or 5 mA (listed to UL 943). A study conducted by UL has shown that such dual-listed devices are effective in mitigating the effects of a glowing contact. A UL STP (Standards Technical Panel) is now considering adding a ground fault protection test to UL 1699. A combination AFCI has the same functionality as a branch/feeder AFCI with the additional ability to detect low-level arcs.
Application Data ■
■
■
■
■
■
FIRE-GUARD AFCI circuit breakers can be applied to all residential, commercial and industrial 15 and 20 ampere, 120/240 Vac applications utilizing a loadcenter approved for use with Cutler-Hammer Type CH or BR circuit breakers. FIRE-GUARD AFCI circuit breakers are to be applied in applications where you want to reduce the risk of electrical fires caused by electrical arcing, as well as protect conductors from overcurrents and short circuits. The single-pole FIRE-GUARD AFCI breaker is applied in single-phase 120 Vac applications. The 2-pole common trip FIRE-GUARD AFCI breaker is applied in 3-wire 120/240 Vac 3-wire circuits and 240 Vac circuits sourced by 120/240 Vac. The 2-pole independent trip FIRE-GUARD AFCI breaker is applied in 120 Vac multi-wired circuits utilizing a shared neutral (often referred to as a home-run circuit). The FIRE-GUARD AFCI/GFCI breaker can be used when AFCI (UL 1699) and 5 mA GFCI (UL 943) protection is required. The FIRE-GUARD AFCI can be used in conjunction with a downstream GFCI device such as a receptacle or ground fault relay.
■
All FIRE-GUARD AFCI type breakers are HACR rated. ■ All FIRE-GUARD AFCI 15 and 20 ampere breakers are SWD rated. The 2-pole AFIT (Arc Fault Independent Trip) breaker is required for shared neutral circuits. In many cases, contractors will run one of 3-conductor wire in lieu of two runs of 2-conductor wire. (Note: When discussing the number of conductors in NM-B cable, the ground wire is not counted. Therefore, the 3-conductor NM-B has two hot and one neutral wire.) This wiring method saves a considerable amount of labor. The 3-conductor is connected to two individual circuit breakers, and the two circuits share the neutral and ground wires. AFCI breakers wire in the same manner as GFCI in that the neutral wire is brought back and connected to the breaker, and the pigtail of the breaker is wired to the neutral bar. In a shared neutral application, since two circuits are sharing one neutral wire, it is impossible to connect the one neutral wire to two individual circuit breakers. The AFIT allows for both circuits to share the neutral wire.
Technical Data and Specifications Impact of Arc Fault Breakers The FIRE-GUARD AFCI represents a major step forward in electrical safety: a step which is expected to have a major impact on the quoted fire statistics. In particular, the Consumer Product Safety Commission (CPSC) has reported that more than 35 percent of all electrical wiring fires are associated with the fixed wiring in Zone 1, and the present AFCI will respond to both parallel and series arcs in this zone (see Figure 4-9). The Task Force of the NEMA Molded Case Circuit Breaker Section also analyzed fire statistics provided by a major insurance company. Figure 4-10 shows the percentage of electrical fires associated with the various zones. This figure again indicates that many fires are associated with Zone 1, with statistics similar to those reported by CPSC.
For more information visit: www.eaton.com
In addition to detecting and interrupting potentially dangerous arcs in Zone 1, the present AFCI would also detect parallel arcs in Zones 2 and 3, and respond to all arcs to ground (see Figure 4-9). As such, the circuit breaker and AFCI represent a major safety improvement over the presentday circuit breakers. It must be noted that AFCIs will mitigate the effect of arcing faults, but will not eliminate them completely. Even under optimum conditions, there will always be at least one arcing halfcycle, and this could cause ignition at high currents.
Figure 4-9. Division of residential wiring into four zones. Zone 0 is associated with the meter, meter socket and service cable; Zone 1 with the loadcenter and the fixed premise wiring; Zone 2 with the wiring between the receptacles and the loads; and Zone 3 with the appliances and other loads.
Figure 4-10. Percentage of Electrical Fires Associated with the Zones Defined in Figure 4-9.
CA08101001E
Advanced Residential Products Arc Fault Circuit Interrupter (AFCI)
4-33
February 2007
FIRE-GUARD
Typical Causes of Arcing Faults
TYPE
CABLE
Arcing faults can occur in homes, apartments, or any other residential dwellings where there is deterioration in wire insulation caused by one or more of these hazardous situations.
Figure 4-11. When cable has been punctured by a nail or stapled too tightly against a stud, the insulation can be severed and arcing can occur.
Figure 4-12. Damaged, abused or worn extension cords can pose an arcing situation.
Table 4-24. Protection Capabilities Protection Device
Type of Protection
Circuit Breaker with Thermal Arc Fault Circuit Magnetic Interruption (AFCI) AFCI Circuit Breaker with Thermal AFCI and GFCI Magnetic
Protects conductor against overload Protects conductor against short circuits Reduces risk of electrical fires started by arcing faults Protects conductor against overloads Protects conductor against short circuits
GFCI Circuit Board (5 mA leakage detection)
Protects people from fatal electric shock
AFCI
Reduces risk of electrical fires started by arcing faults
Standards and Certifications ■
Cutler-Hammer AFCIs are listed to UL 1699, the standard for arc fault circuit interrupters and UL 489, the standard for circuit breakers. ■ AFCIs with 5 mA GFCI protection are available that meet UL 943, the standard for ground fault circuit interrupters. ■ NEC 210.12 – 2002 NEC A. Definition — An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected. B. Dwelling Unit Bedrooms — All branch circuits that supply 125-volt, single-phase, 15- and 20-ampere outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter listed to provide protection of the entire branch circuit.
CA08101001E
Advantage
For more information visit: www.eaton.com
■
Proposed NEC 210.12 – 2005 NEC A. Definition — An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when an arc fault is detected. B. Dwelling Unit Bedrooms — All branch circuits that supply 125-volt, single-phase, 15- and 20-ampere outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter, combination type, listed to provide protection of the entire branch circuit. Branch/ feeder AFCIs are allowed to be used until January 1, 2008.
4
Advanced Residential Products Arc Fault Circuit Interrupter (AFCI)
4-34
February 2007
FIRE-GUARD
Product Selection
120/240 Vac Source N A B
Table 4-25. Type CH 3/4-Inch (19.1 mm) Wide FIRE-GUARD AFCI Circuit Breakers
4
Poles
Ampere Rating
Configuration
Catalog Number
Single-Pole 10 kAIC
15
AFCI AFCI with GFCI AFCI in Clamshell Package
CH115AF CH115AFGF CH115AFCS
AFCI AFCI with GFCI AFCI in Clamshell Package
CH120AF CH120AFGF CH120AFCS
15
AFCI Common Trip AFCI Independent Trip AFCI Common Trip with GFCI
CH215AF CH215AFIT CH215AFGF
20
AFCI Common Trip AFCI Independent Trip AFCI Common Trip with GFCI
CH220AF CH220AFIT CH220AFGF
20
Double-Pole 10 kAIC
Price U.S. $
Line B
1 Pole Neutral 120 V Duplex Receptacle
Neutral
Equipment Ground
Figure 4-13. Single-Pole Single 120 Volt Load Application Sourced by 120/240 Vac
Common trip refers to 2-pole 240 volt load application sourced by 120/240 Vac (See Figure 4-15). Independent trip refers to 2-pole shared neutral circuits (see Figure 4-14 and Figure 4-16).
120/240 Vac Source N A B Line B
Table 4-26. Type BR 1-Inch (25.4 mm) Wide AFCI Circuit Breakers Poles
Single-Pole 10 kAIC
Ampere Rating
Configuration
15
AFCI AFCI with GFCI AFCI in Clamshell Package
BR115AF BR115AFGF BR115AFCS
AFCI AFCI with GFCI AFCI in Clamshell Package
BR120AF BR120AFGF BR120AFCS
AFCI Common Trip AFCI Independent Trip AFCI Common Trip with GFCI
BR215AF BR215AFIT BR215AFGF
AFCI Common Trip AFCI Independent Trip AFCI Common Trip with GFCI
BR220AF BR220AFIT BR220AFGF
20
Double-Pole 10 kAIC
15
20
Catalog Number
Price U.S. $
2 Pole Neutral Neutral
2-120 V Duplex Receptacles
Line A Equipment Ground
Figure 4-14. 2-Pole Shared Neutral with Multi-Duplex Receptacle Application
Common trip refers to 2-pole 240 volt load application sourced by 120/240 Vac (See Figure 4-15). Independent trip refers to 2-pole shared neutral circuits (see Figure 4-14 and Figure 4-16).
120/240 Vac Source N A B Line B
Table 4-27. UL Classified AFCIs Poles
Ampere Rating
Configuration
Catalog Number
Price U.S. $
Type CL 1-Inch Wide per Pole Classified Arc Fault Circuit Interrupters — Fit Square D HOMELINE , GE, Siemens, Murray , Thomas & Betts and Crouse-Hinds Loadcenters Single-Pole
15 20
AFCI AFCI
CL115AF CL120AF
15 20
AFCI/GFCI AFCI/GFCI
CL115AFGF CL120AFGF
Type CHQ 3/4-Inch Wide per Pole Classified Arc Fault Circuit Interrupters — Fit Square D QO Loadcenters Single-Pole
15 20
AFCI AFCI
CHQ115AF CHQ120AF
15 20
AFCI/GFCI AFCI/GFCI
CHQ115AFGF CHQ120AFGF
2 Pole Line A
240 V Duplex Receptacle
Neutral Equipment Ground
Figure 4-15. 2-Pole 240 Volt Load Application Sourced by 120/240 Vac
120/240 Vac Source N A B Line B Line A
NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL and cUL are federally registered trademarks of Underwriters Laboratories Inc. General Electric is a federally registered trademark of General Electric Company. Lexan is a registered trademark of General Electric Co., USA. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. Windows is a registered trademark of Microsoft Corporation. Cutler-Hammer is a federally registered trademark of Eaton Corporation. Square D is a federally registered trademark of Schneider Electric. Siemens is a federally registered trademark of Siemens AG. Briggs & Stratton is a registered trademark of Briggs & Stratton Corporation. Windows is a registered trademark of Microsoft Corporation. Panamax is a registered trademark of Panamax Corporation.
Wiremold is a registered trademark of The Wiremold Company and its subsidiaries. Murray is a federally registered trademark of Siemens Energy & Automation, Inc. HOMELINE is a registered trademark of Schneider Electric. Crouse-Hinds is a federally registered trademark of Cooper Industries. Thomas & Betts is a federally registered trademark of Thomas & Betts Corporation. OnQ is a registered trademark of The Whitaker Corporation used under license to OnQ Technologies Inc. Home Director is a registered trademark of Home Director, Inc. Siemon Home Cabling System is a registered trademark of The Siemon Company. Greyfox is a trademark of Greyfox Systems Inc. Ford is a registered trademark of Ford Motor Company. Isuzu is a registered trademark of Isuzu Motors America, Inc.
2 Pole
Neutral
Neutral 120 V Duplex Receptacle (With Line Side Jumper Removed) Equipment Ground
Figure 4-16. 2-Pole Shared Neutral with Duplex Receptacle Application Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD
For more information visit: www.eaton.com
CA08101001E