Power Outlet Panels
6-1
Power Outlet Panels
February 2007
Contents Description
Page
Power Outlet Panels Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Outlet Panel Receptacle Configuration Rules . . . . . . . . . . . . . . . . Unmetered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unmetered Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metered Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unmetered Back-to-Back Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . Metered Back-to-Back Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mobile Home Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receptacle Deadfront Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-3 6-3 6-5 6-5 6-6 6-7 6-7 6-8 6-8 6-8 6-8 6-9 6-15 6-16 6-16
Don’t Give Up! If you don’t find the product you want in this catalog, try the Flex Center at 1-800-330-6479.
Power Outlet Panel Family
CA08101001E
For more information visit: www.eaton.com
6
6-2
Power Outlet Panels February 2007
Product Description
Product Description A Power Outlet Panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. Construction sites and RV parks need to provide a safe and reliable means for users to access electricity and POPs provide the outlets for electrical access.
6
RV Park Application
Receptacles and Circuit Protection
When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of providing power to the vehicle’s appliances. Many RV parks now supply users with lighted POPs with TV and telephone jacks. A move towards offering more amenities at RV parks.
The circuit protection shall be Eaton’s Cutler-Hammer UL listed full-size Type BR or half-size Type BD circuit breakers. The receptacles shall be NEMA commercial/industrial grade and come in a wide variety of configurations. Ground fault protection (GFCB) shall be provided at the 20 ampere duplex NEMA 5-20R receptacle or 20 ampere single-pole circuit breaker when required. Ground fault protection shall be provided at the circuit breaker for receptacles above 20 amperes when required.
Application Description Power Outlet Panels or POPs are also sometimes called Temporary Power Panels, Temporary Site Service Equipment or RV Panels.
Construction
Construction Site Application When POPs are used at a construction site, they are installed on a temporary basis until electrical power is available at the building. The most common reason for needing a POP at a construction site is to provide a power source for the contractor’s tools.
RV Park Application
Standards and Certifications UL Standard 231. UL File Number E163588. ■ Receptacles conform to NEMA and/ or ANSI configurations as specified by the National Electrical Code . ■
■
Product Specifications
Construction Site Application
The power outlet panels shall be designed for outdoor service to meet temporary power outlet requirements at construction sites and provide high quality, economical power to individual sites at recreational vehicle (RV) parks. Construction site panels shall be provided with means to bond the neutral for service entrance applications. RV panels shall have a factory-installed insulated neutral bar.
For more information visit: www.eaton.com
The power outlet panel pedestal shall be of deadfront design and constructed of heavy gauge, 100 percent galvanized steel. Baked-on polyester powder coating shall be used for excellent mechanical strength, plus resistance to chalking caused by the sun’s ultraviolet rays. The power outlet panel surface and pedestal units shall have NEMA Type 3R rainproof enclosures.
Ease of Installation Panels shall ship from the factory completely assembled, prewired with 100 percent copper wire, and tested in accordance with UL Standard 231. Door shall swing up and open for user convenience and ease of access to breakers and receptacles. When required, a means for securing the door in the open position shall be provided. Panels shall be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Knockouts shall range from 1/2-inch (12.7 mm) to 1-1/2 inches (38.1 mm). #4 – 14 Cu/Al grounding provisions shall be provided on all panels.
Standard Compliance All power outlet panels for temporary construction site power and RV (recreational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E163588. Receptacles shall conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC).
CA08101001E
Power Outlet Panels
6-3
February 2007
Surface and Pedestal Units
Eaton’s Cutler-Hammer Power Outlet Panels Power Where You Need It, When You Need It Features ■ ■
■ ■
■
Designed for outdoor service to meet power outlet requirements. Receptacles conform to NEMA and/ or ANSI configurations as specified by NEC. Suitable for use as service entrance equipment. Includes a factory installed insulated neutral bar with provisions for bonding when used for service entrance applications. 125 ampere rated meter socket.
Designed for Easy Installation and Protection ■
■
■
■
■
■
Panels come from the factory completely assembled, prewired with 100 percent copper wire and tested...ready for easy installation. Door swings up and open for user convenience and ease of access to breakers and receptacles. Panels can be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Two-piece deadfront cover allows field wiring without interfering with factory wiring. Lower deadfront cover permits easy field wiring to circuit protective devices. GFI (ground fault interrupter) 1- and 2-pole protection through 50 amperes.
Two Styles to Meet Your Power Outlet Needs Surface Mount: User mounts unit to a post. Pedestal Mount: User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See accessories Page 6-15 for part numbers and options.)
Surface Units NEMA 3R construction for rainproof installation. 100 percent galvanized steel with baked-on polyester powder coating.
Utility grade metering available for construction site RV park applications.
Three-point mounting.
Door swings up and pushes in to lock into open position. Pull out and push down to close door.
One-piece case back for metered and unmetered panels. Lighted option for site location and nighttime panel operations. GFI circuit breakers available through 50 amperes. Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked.
• Metered units available with meter on top or on bottom.
Removable upper deadfront cover for easy incoming wire connections to breaker terminals.
Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts. Padlock provisions to prevent unauthorized entry.
• Units are factory wired and assembled.
Pedestal Units
NEMA 3R construction for rainproof installation.
100 percent galvanized steel with baked-on polyester powder coating.
Utility grade metering available for construction site RV park applications.
Door swings up and pushes in to lock into open position. Pull out and push down to close door. GFI circuit breakers (1- and 2-pole) available through 50 amperes.
One-piece case back for metered and unmetered panels.
Loop feed lug assembly with 350 kcmil lugs as standard.
Removable upper deadfront cover for easy incoming wire connections to breaker terminals. Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked. Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts. Padlock provisions to prevent unauthorized entry.
Pedestal extension available for underground services. Pad-mounted bracket option also available.
• Units are factory wired and assembled.
CA08101001E
For more information visit: www.eaton.com
6
6-4
Power Outlet Panels February 2007
Surface and Pedestal Units
Cutler-Hammer Power Outlet Panels Surface Units
6
Unmetered Type
Metered Ring or Ringless Type
Metered Ring or Ringless Type Bottom Feed
Single Receptacle
Pedestal Units
Unmetered Type Metered Ring or Ringless Type
For more information visit: www.eaton.com
Back-to-Back Type
CA08101001E
Power Outlet Panels
6-5
February 2007
Product Selection
Product Selection ■
When quoting or selecting a Power Outlet Panel, the following questions should be answered:
Unmetered, Ring or Ringless Style. Number and types of receptacles (7 standard and 8 twist-lock options). ■ Standard or Ground Fault Breakers. ■
■
Surface, Pedestal or Back-to-Back Mounting. ■ Are any factory or field options required?
Table 6-1. Catalog Numbering System
CH M 1 N 7 N 4 N P X L TZ U Feed
Cutler-Hammer
U = Bottom Fed Blank = Top Fed
Metering Type U = Unmetered M = Metered-Ring R = Metered-Ringless Receptacle Type Left Position 1= 2= 3= 4= 5= 6= 7= Blank =
NEMA 14-50R NEMA 10-50R NEMA 14-30R NEMA TT-30R NEMA 6-20R2 NEMA 5-20R2 NEMA 5-20R2GFI No Receptacle
Receptacle Type Center Position 1 = NEMA 14-50R 2 = NEMA 10-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA 6-20R2 6 = NEMA 5-20R2 7 = NEMA 5-20R2GFI Blank = No Receptacle
Circuit Breaker Type Position 1
Receptacle Type Right Position 1= 2= 3= 4= 5= 6= 7=
NEMA 14-50R NEMA 10-50R NEMA 14-30R NEMA TT-30R NEMA 6-20R2 NEMA 5-20R2 NEMA 5-20R2GFI
Circuit Breaker Type Position 2 N = Non-Ground Fault G = Ground Fault
N = Non-Ground Fault G = Ground Fault
TZ = Factory Installed Pedestal Extension with Lay-in Ground Lug L = Lighted Interior X = Six Circuit Blank = Standard Four Circuit Mounting S = Surface P = Pedestal B = Back-to-Back Pedestal Circuit Breaker Type Position 3 N = Non-Ground Fault G = Ground Fault
For receptacle configurations, see Table 6-2. Only available with metered surface mount units.
Note: Twist-lock receptacles are not listed in the above chart as not all receptacle combinations are valid even though one can create a catalog number above. Contact Eaton for a quote on twist-lock and custom receptacle/breaker combinations.
Table 6-2. Receptacle Configuration 1
50 ampere, 125/250 volt 3-pole, 4-wire, NEMA 14-50R
5
2-pole 50 ampere breaker 2
50 ampere, 125/250 volt 2-pole, 3-wire, NEMA 10-50R
2-pole 20 ampere breaker 6
2-pole 50 ampere breaker 3
30 ampere, 125/250 volt 3-pole, 4-wire, NEMA 14-30R 2-pole 30 ampere breaker
4
20 ampere, 250 volt, 2-pole, 3-wire, NEMA 6-20R2
20 ampere, 125 volt, 2-pole, 3-wire, NEMA 5-20R2 1-pole 20 ampere breaker
7
20 ampere, 125 volt, 2-pole, 3-wire, NEMA 5-20R2GFI 1-pole 20 ampere breaker
30 ampere, 125 volt 2-pole, 3-wire, NEMA TT-30R 1-pole 30 ampere breaker
CA08101001E
For more information visit: www.eaton.com
6
Power Outlet Panels
6-6
February 2007
Product Selection
Product Selection Built to Order
Power Outlet Panel List Price Configurator Table 6-3. Base Price Description
Price U.S. $
■
Configure catalog number. ■ Calculate list price. ■ Lead-time: ❑ 3 days up to 15 units ❑ 10 days up to 50 units
6
Unmetered Surface Metered Surface Unmetered Pedestal Metered Pedestal Unmetered Back-to-Back Metered Back-to-Back
Power Outlet Panel Receptacle Configuration Rules
Note: Contact your local Eaton sales office for current pricing.
Four Receptacles/Unit
Table 6-4. Receptacle/Breaker Adders
All receptacles must be NEMA 5-20R and/or NEMA 5-20R2, surface mount only.
Three Receptacles/Unit ■
One or more of the receptacles must be NEMA 6-20R2, NEMA 5-20R2 or NEMA 5-20R2GFI. ■ NEMA 6-20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position. ■ If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA 6-20R2 a six-circuit interior must be added. ❑ Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position.
Two, One and Zero Receptacles/Unit ■
Any configuration.
Configuration
Description
Price U.S. $
1N 1G
NEMA 14-50R
with 2-Pole 50 Ampere Breaker with 2-Pole 50 Ampere GFI Breaker
2N 2G
NEMA 10-50R
with 2-Pole 50 Ampere Breaker with 2-Pole 50 Ampere GFI Breaker
3N 3G
NEMA 14-30R
with 2-Pole 30 Ampere Breaker with 2-Pole 30 Ampere GFI Breaker
4N 4G
NEMA TT-30R
with 1-Pole 30 Ampere Breaker with 1-Pole 30 Ampere GFI Breaker
5N 5G
NEMA 6-20R2
with 2-Pole 20 Ampere Breaker with 2-Pole 20 Ampere GFI Breaker
6N 6G
NEMA 5-20R2
with 1-Pole 20 Ampere Breaker with 1-Pole 20 Ampere GFI Breaker
7N
NEMA 5-20R2GFI
with 1-Pole 20 Ampere Breaker
Note: Contact your local Eaton sales office for current pricing.
Table 6-5. Options Option
Price U.S. $
Six Circuit Interior Factory-Mounted Pedestal Extension Lighted Bottom Fed
Note: Contact your local Eaton sales office for current pricing.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-7
February 2007
Product Selection
Product Selection (Continued) Table 6-6. Surface Type Ampere Series
Receptacle Description
Breaker Description
Position
1st
2nd
3rd
UPC Number 78211
Catalog Number
Left
Center
Right
Price U.S. $
Unmetered Single Receptacle 50 50 30 30
— — — —
14-50R 10-50R 14-30 R TT-30R
— — — —
No Breaker No Breaker No Breaker No Breaker
No Breaker No Breaker No Breaker No Breaker
No Breaker No Breaker No Breaker No Breaker
6128174 6128181 6128198 6128204
CHU1S CHU2S CHU3S CHU4S
20 20 20
— — —
6-20R2 5-20R2 5-20R2GFI
— — —
No Breaker No Breaker No Breaker
No Breaker No Breaker No Breaker
No Breaker No Breaker No Breaker
6128211 6128228 6128235
CHU5S CHU6S CHU7S
20/20/20 20/20/20 20/20/20
5-20R2 5-20R2GFI 5-20R2GFI
5-20R2 5-20R2GFI 5-20R2GFI
6-20R2 6-20R2 6-20R2
GFI Non-GFI Non-GFI
GFI Non-GFI Non-GFI
GFI Non-GFI GFI
42039 2 42039 4 —
CHU6G6G5GS CHU7N7N5NS CHU7N7N5GS
50/20/30 50/20/30 30/20
5-20R2GFI 14-50R TT-30R
5-20R2GFI 5-20R2GFI 5-20R2GFI
TT-30R 6-20R —
Non-GFI GFI Non-GFI
Non-GFI Non-GFI Non-GFI
Non-GFI Non-GFI —
— — 42037 4
CHU1N7N4NS CHU1G7N7NS CHU4N7NS
20/20 50/20 50/20
5-20R2GFI 14-50R 14-50R
5-20R2GFI 5-20RGFI 5-20RGFI
— — —
Non-GFI GFI Non-GFI
Non-GFI Non-GFI Non-GFI
— — —
42037 7 42156 8 42037 0
CHU7N7NS CHU1G7NS CHU1N7NS
50/20/50 50 50/20
14-50R 14-50R 10-50R
5-20R2GFI — 5-20R2GFI
14-50R — —
Non-GFI Non-GFI GFI
Non-GFI — Non-GFI
Non-GFI — —
— — 42156 9
CHU1N7N1NSX CHU1NS CHU2G7NS
30/30/20 50/20 30
TT-30R 10-50R TT-30R 5-20R2
5-20R2GFI 5-20R2GFI — 5-20R2
TT-30R — — 5-20R2
Non-GFI Non-GFI Non-GFI GFI
Non-GFI Non-GFI — GFI
Non-GFI — — GFI
42039 0 42037 2 42036 7
CHU4N7N4NS CHU2N7NS CHU4NS CHU6G6G5GS6OM
Unmetered
Metered — Ring 50/20/20 20/20 20/20/20
14-50R 5-20R2GFI 5-20R2GFI
5-20R2GFI 5-20R2GFI 5-20R2GFI
5-20R2GFI — 6-20R2
GFI Non-GFI Non-GFI
Non-GFI Non-GFI Non-GFI
Non-GFI — GFI
42028 6 42028 3 42156 1
CHM1G7N7NS CHM7N7NS CHM7N7N5GS
20/20/20 50/30/20 50/20 20/20
5-20R2GFI 14-50R 14-50R 6-20R2
5-20R2GFI 5-20R2GFI 5-20R2GFI 5-20R2GFI
6-20R2 TT-30R — —
Non-GFI Non-GFI Non-GFI Non-GFI
Non-GFI Non-GFI Non-GFI Non-GFI
Non-GFI Non-GFI — —
42030 0 42028 8 42027 7 42156 3
CHM7N7N5NS CHM1N7N4NS CHM1N7NS CHM5N7NS
Metered — Ringless 50/20 20/20 50/20/20
14-50R 5-20R2GFI 14-50R
5-20R2GFI 5-20R2GFI 5-20R2GFI
— — 5-20R2GFI
GFI Non-GFI GFI
Non-GFI Non-GFI Non-GFI
— — Non-GFI
42190 7 42032 9 42398 3
CHR1G7NS CHR7N7NS CHR1G7N7NS
50/20 50/20 20/20/20
10-50R 14-50R 5-20R2GFI
5-20R2GFI 5-20R2GFI 5-20R2GFI
— — 5-20R2GFI
GFI Non-GFI Non-GFI
Non-GFI Non-GFI Non-GFI
— — Non-GFI
42398 2 42032 4 42034 7
CHR2G7NS CHR1N7NS CHR7N7N7NS
30/20/20 50/30/20
14-30R 14-50R
5-20R2GFI 5-20R2GFI
5-20R2GFI TT-30R
Non-GFI Non-GFI
Non-GFI Non-GFI
Non-GFI Non-GFI
42034 1 42033 4
CHR3N7N7NS CHR1N7N4NS
5-20R2GFI 5-20R2GFI 5-20R2GFI
— 6-20R2 5-20R2GFI
Non-GFI Non-GFI GFI
Non-GFI Non-GFI Non-GFI
— GFI Non-GFI
615327 5 615330 5 615329 9
CHM7N7NSU CHM7N7N5GSU CHM1G7N7NSU
Metered — Ring — Bottom Fed 20/20 20/20/20 50/20/20
5-20R2GFI 5-20R2GFI 14-50R
Metered — Ringless — Bottom Fed 20/20 50/20 50/20
5-20R2GFI 14-50R 10-50R
5-20R2GFI 5-20R2GFI 5-20R2GFI
— — —
Non-GFI GFI GFI
Non-GFI Non-GFI Non-GFI
— — —
615326 8 615328 2 615338 1
CHR7N7NSU CHR1G7NSU CHR2G7NSU
20/20/20 20/20/20 20/20/20
5-20R2GFI 5-20R2GFI 5-20R2GFI
5-20R2GFI 5-20R2GFI 5-20R2GFI
6-20R2 6-20R2 5-20R2GFI
Non-GFI Non-GFI Non-GFI
Non-GFI Non-GFI Non-GFI
GFI Non-GFI Non-GFI
615331 2 615332 9 615337 4
CHR7N7N5GSU CHR7N7N5NSU CHR7N7N7NSU
30/20/20 30/20/20 50/20/20 50/20/30
14-30R 14-30R 14-50R 14-50R
5-20R2GFI 5-20R2GFI 5-20R2GFI 5-20R2GFI
5-20R2GFI 5-20R2GFI 5-20R2GFI TT-30R
Non-GFI GFI GFI Non-GFI
Non-GFI Non-GFI Non-GFI Non-GFI
Non-GFI Non-GFI Non-GFI Non-GFI
615333 6 615334 3 615336 7 615335 0
CHR3N7N7NSU CHR3G7N7NSU CHR1G7N7NSU CHR1N7N4NSU
Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson. The “X” suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior. Includes 60 ampere 2-pole main breaker for service disconnect ratings. Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson. Note: Contact your local Eaton sales office for configurations not listed.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E
For more information visit: www.eaton.com
6
Power Outlet Panels
6-8
February 2007
Product Selection Table 6-7. Pedestal Type Ampere Series
Receptacle Description
Breaker Description
Position
1st
2nd
3rd
UPC Number 78211
Catalog Number
Left
Center
Right
50/30/20 30/20
14-50R TT-30R
5-20R2GFI 5-20R2GFI
TT-30R —
Non-GFI Non-GFI
Non-GFI Non-GFI
Non-GFI —
42038 2 42031 7
CHU1N7N4NP CHU4N7NP
50/30/20 30/30/20
14-50R TT-30R
5-20R2GFI 5-20R2GFI
TT-30R TT-30R
Non-GFI Non-GFI
Non-GFI Non-GFI
Non-GFI Non-GFI
42038 3 42032 1
CHU1N7N4NPTZ CHU4N7N4NP
5-20R2GFI 5-20R2GFI
TT-30R —
Non-GFI Non-GFI
Non-GFI Non-GFI
Non-GFI —
42030 4 42231 5
CHM1N7N4NP CHM1N7NP
5-20R2GFI
TT-30R
Non-GFI
Non-GFI
Non-GFI
42031 0
CHR1N7N4NP
Price U.S. $
Unmetered
Metered — Ring
6
50/30/20 50/20
14-50R 14-50R
Metered — Ringless 50/30/20
14-50R
Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson. Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson. Note: Contact your local Eaton sales office for configurations not listed.
Table 6-8. Back-to-Back Pedestal Type Ampere Series
Receptacle Description
Breaker Description
Position
1st
2nd
3rd
UPC Number 78211
Catalog Number
Left
Center
Right
TT-30R
5-20R2GFI
TT-30R
Non-GFI
Non-GFI
Non-GFI
42036 4
CHU4N7N4NB
5-20R2GFI 5-20R2GFI
— TT-30R
Non-GFI Non-GFI
Non-GFI Non-GFI
— Non-GFI
42034 8 42035 0
CHM4N7NB CHM1N7N4NB
5-20R2GFI
TT-30R
Non-GFI
Non-GFI
Non-GFI
42035 7
CHR1N7N4NBTZ
Price U.S. $
Unmetered 30/30/20
Metered — Ring 30/20 50/30/20
TT-30R 14-50R
Metered — Ringless 50/30/20
14-50R
Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson. The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs. Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson. Note: Contact your local Eaton sales office for configurations not listed.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-9
February 2007
Product Selection
Dimensional Drawings
6.58 (167.1)
0.24 (6.1)
2.63 (66.8)
6
7.10 (108.3) 4.50 (114.3)
3.18 (80.8) 1.30 (33.0) 2.50 (63.5)
1.87 (47.5 )
6.23 (158.2)
4.79 (121.7) 4.27 (108.5)
0.13 (3.3)
Figure 6-1. Single Receptacle CA08101001E
For more information visit: www.eaton.com
6-10
Power Outlet Panels February 2007
Product Selection
Ringless U.G. Feed Pedestal-Mount B/B
6
Hit Exit Hole B/B Only
18.02 (457.7)
8.25
33.00 (838.2)
33.00 (838.2)
Figure 6-2. 100 Amperes Back-to-Back
For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-11
February 2007
Product Selection
Ringless U.G. Feed Pedestal-Mount.
.79 (20.1)
6 0.24 260.0)
10.78 (273.7)
Gasket .92 (23.4)
4.00
Hit Exit Hole B/B Only
6.10 (154.9)
18.02
wer Barrier
33.00 (838.2)
Figure 6-3. 100 Ampere Pedestal CA08101001E
For more information visit: www.eaton.com
33.00 (838.2)
6-12
Power Outlet Panels February 2007
Product Selection
Dimensions in Inches (mm) — Metered Units (Ring and Ringless) 4.50 (114.3) 4.30
9.50
.07
6
30.00 (762.0) 22.50 (571.5) Locking Provision
Sealing Provision
(170.1)
Figure 6-4. Metered Surface Type
9.50 (241.3)
5.00 (127.0)
52.00 (1320.8)
6.80 (172.7) 4.30 (109.2)
Locking Provision
44.50 (1130.3)
25.80 (655.3)
22.00 (558.8) 16.90 (429.3)
Sealing Provision
Figure 6-5. Metered Pedestal Type For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-13
February 2007
Product Selection
Dimensions in Inches (mm) — Metered Units (Ring and Ringless)
6
Figure 6-6. Metered Back-to-Back Pedestal Type 6.80 (172.8) 4.31
9.49 (241.1)
.06 (1.6)
Locking Provision
30.10 (764.6)
17.11 (434.7) 12.97 (329.4) 6.15 (156.2)
Sealing Provision
Figure 6-7. Bottom Fed Type CA08101001E
For more information visit: www.eaton.com
4.93 (125.2)
6-14
Power Outlet Panels February 2007
Product Selection
Dimensions in Inches (mm) — Unmetered Units 9.50 (241.3)
4.30 (109.2) .07 (1.7)
6
17.10 (434.3)
14.50 (368.3) Locking Provision
1.30 (33.0)
6.70 (170.2)
Figure 6-8. Unmetered Surface Type 9.50 (241.3)
13.60 (345.4) 8.60 (218.4)
9.50
Locking Provision 17.10 (434.3) 39.10 (993.1) 39.90 (1013.5)
19.20 (487.7)
9.20 (233.7) 9.40 (238.8)
Figure 6-9. Unmetered Pedestal Type
.75 (19.1)
3.30 (83.8)
Figure 6-10. Unmetered Back-to-Back Pedestal Type
For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-15
February 2007
Accessories and Replacement Parts
Accessories and Replacement Parts Table 6-9. Accessories and Replacement Parts Description
UPC Catalog Number Number 78211
Price U.S. $
Pad-Mount Bracket
Accessories Underground Pedestal Extension Stainless Steel Underground Pedestal Extension Pad-Mount Bracket
420273 422130 420274
CHPEDEXT CHPEDEXTSS CHPADEXT
Cable TV and Telephone Bracket
420275
CHTELTV
Rainproof Conduit Hub 0.75 inch (19.1 mm) Rainproof Conduit Hub 1.00 inch (25.4 mm) Rainproof Conduit Hub 1.25 inch (31.8 mm) Rainproof Conduit Hub 1.50 inch (38.1 mm)
310991 310992 310993 310994
DS075H1 DS100H1 DS125H1 DS150H1
Fluorescent Light Kit — Converts power outlet panel to lighted unit, must also order CHOUTCVRL.
463424
CHFLGTKIT
Replacement Meter Socket Replacement Meter Socket Replacement Meter Socket (1 Block Assembly Per Kit)
481999 612728 603686
CHPOPMS CHPOPMSN ARP00039CH
5th Jaw Kit 5th Jaw Kit Bonding Strap and Mounting Hardware Horn Bypass (1 Lug Cap Per Kit; 4 Kits Required Per Device) Horn Bypass (1 Kit Required Per Device)
600788 400413 421926 612840 438033
1MM5JKOP ARP00035CHJ CHBONDST ARP00777CH 1MMBPH
Inner Lens for Lighted Power Outlet Panels Loop Feed Lug Assembly for Single Pedestal Loop Feed Lug Assembly for Back-to-Back Pedestal
421927 421928 421929
CHINLENS CHLOOPFDP CHLOOPFDB
Blank Lower Deadfront Cover Lower Deadfront Cover with Duplex Receptacle Opening Lower Deadfront Cover with Duplex, Duplex Receptacle Opening
421930 421931 421932
CHLDFCVR CHLDFCVR1 CHLDFCVR2
421933 421934
CHLDFCVR3 CHLDFCVR4
421935
CHLDFCVR5
DS Hub Underground Pedestal Extension Inner Lens
Replacement Parts
Lower Deadfront Cover with Duplex, Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Rectangle Receptacle Opening Lower Deadfront Cover with Rectangle, Rectangle Receptacle Opening
Lower Deadfront Cover with Rectangle, Rectangle, Rectangle Receptacle Opening 421936 Lower Deadfront Cover with Duplex, Rectangle Receptacle Opening 421937 Lower Deadfront Cover with Duplex, Rectangle, Duplex Receptacle Opening 421938 Lower Deadfront Cover with Rectangle, Rectangle, Duplex Receptacle Opening Lower Deadfront Cover with Round Receptacle Opening Lower Deadfront Cover with Round, Round Receptacle Opening Lower Deadfront Cover with Round, Duplex Receptacle Opening Lower Deadfront Cover with Round, Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Round, Duplex, Round Receptacle Opening
CHLDFCVR6 CHLDFCVR7
421939 421940 422128
CHLDFCVR9 CHLDFCVR10 CHLDFCVR11
422129
CHLDFCVR12
421942
CHLDFCVR13 CHLDFCVR14 CHLDFCVR15
CHLDFCVR18 CHUDFCVR CHUDFCVRL
Power Head Outer Cover Power Head Outer Cover with Lens
421949 421950
CHOUTCVR CHOUTCVRL
6-Hole Neutral Assembly with 2/0 Lug 7-Hole Neutral Assembly with 2/0 Lug 5-Hole Ground Bar Kit 10-Hole Ground Bar Kit
421951 422180 309906 401456
CHNEUT CHNEUT1 GBK5 GBK10
Replacement Meter Cover — Ring Type Replacement Meter Cover — Ringless Replacement Meter Cover — Ringless Replacement Meter Cover — Ringless
483847 483848 612729 641914
CHPOPRMC CHPOPRLMC CHPOPRLMCN CHPOPRLMCN2
For Power Outlet Panels manufactured before 12/1/02. For Power Outlet Panels manufactured after 12/1/02. For Power Outlet Panels with a date code ending in L. For Power Outlet Panels with a date code not ending in L.
CA08101001E
Power Head Outer Cover
Loop Feed Lug Assembly
CHLDFCVR17
422079 421947 421948
Neutral Assemblies
CHLDFCVR16
Lower Deadfront Cover with Round, Rectangle, Duplex Receptacle Opening Upper Deadfront Cover with Six Breaker Twistouts Upper Deadfront Cover with Provisions for Lighted Option
Power Head Outer Cover with Lens
Meter Socket 421943
Cable TV/ Telephone Bracket
CHLDFCVR8
Lower Deadfront Cover with Round, Rectangle Receptacle Opening 421944 Lower Deadfront Cover with Round, Rectangle, Rectangle Receptacle Opening 421945 Lower Deadfront Cover with Round, Rectangle, Round Receptacle Opening 421946
6
For more information visit: www.eaton.com
Lower Deadfront Cover
Upper Deadfront Cover
Bonding Strap and Mounting Hardware Circuit Breaker (BR/GFCB)
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD
Power Outlet Panels
6-16
February 2007
Product Selection
Mobile Home Panels The versatile Cutler-Hammer Mobile Home Panels have a user-friendly design that allows for a faster, cleaner installation — letting you move on to your next job sooner.
6
100 and 200 ampere panels come complete with the main breaker and a 4/8 or 8/16 interior, respectively. The 200 ampere units are designed about 5 inches wider than other manufacturer’s panels to ensure plenty of room for wire bending and an easier wiring job.
Receptacle Deadfront Kits
Fastenerless Socket Design
200 ampere units include a new door. Optional receptacle deadfront kits can supply power for a variety of applications including:
■
■ ■ ■ ■ ■
Visiting RVs. Pool filters. Weed whackers. Air compressors. Anything else that requires power (receptacles and breakers supplied by contractor).
■
Makes failure a non-issue. No socket connections that overheat.
Pedestal Unit ■
Convenient and sturdy ground mounting. ■ Loop feed feature allows several units to be connected in series.
Easier, Better and Faster Installation ■
More wire bending and viewing room. ■ Additional circuits mean more flexibility.
Table 6-10. Mobile Home Panels Amperes
Security
Interior
Main
Branch Breakers
Mounting
Receptacles
UPC Number Catalog 78211 Number
100 100 100 100
Ring Ring Ringless Ringless
4/8 4/8 4/8 4/8
BR2100 BR2100 BR2100 BR2100
BR BR BR BR
Pedestal Back-to-Back Pedestal Back-to-Back
None None None None
498168 9 498169 6 498170 2 498171 9
MHM100P MHM100B MHR100P MHR100B
150 150 150 150
Ring Ring Ringless Ringless
8/16 8/16 8/16 8/16
BWH2150 BWH2150 BWH2150 BWH2150
BR BR BR BR
Pedestal Back-to-Back Pedestal Back-to-Back
None None None None
617535 2 617534 5 616475 2 616474 5
MHM150P MHM150B MHR150P MHR150B
200 200 200 200
Ring Ring Ringless Ringless
8/16 8/16 8/16 8/16
BWH2200 BWH2200 BWH2200 BWH2200
BR BR BR BR
Pedestal Back-to-Back Pedestal Back-to-Back
None None None None
498172 6 498173 3 498174 0 498175 7
MHM200P MHM200B MHR200P MHR200B
200
Ringless
8/16
BWH2200
BR
Pedestal
Qty 1 14-50R Qty 2 TT-30R
498176 4
MHM200P1N4N4N
Price U.S. $
Pedestal Extension included with Mobile Home Panels.
For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-17
Product Selection February 2007
Product Selection
Ringless Socket Rated 200 A Continuous 5.31
Sealin 5/16 (7.9) Diameter KO Opposite Side Only
6
1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout
1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) Knockout
57.81 (1468.3)
200A
50.08 (1272.1) Optional Direct Feed Kit Shown Installed (Cover Not Shown) 27.87 (708.0)
28.01 (711.5)
43.20 (1097.4)
28.70 (729.0)
24.65 (626.1)
2.00 (50.8)
1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO
1/2, 3/4,1 (12.7, 19.1, 25.4) KO (2 Required)
23.69 (601.8)
1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO
Sealing Provision 1.21
Grade Level
Figure 6-11. Mobile Home Panel — Ringless Security — Pedestal Mounting Front View
Back View
12.09 (307.2)
Ringless Socket Rated 200 A Continuous 10
14.45
1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) KO (2) Required Sealing Provision 57.81 (1468.3) Door Not Shown
5/16 (7.9) Diameter
Door Not Shown
Side Only
1,1-1/4, 1-1/2, 2
1-1/4, 1-1/2,
Diameter KO
(31.8, 38.1, 50.8, 63.5) Knockout
Side Only
1/2 (12.7) KO (3) Required 3/4, 1 (19.1, 25.4) KO KO (3) Required
200A Main KO (2) Required
1-1/2, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO
Bottom Endwall Back Unit
50.08 (1272.1)
(1097.4)
27.87 (708.0)
22.01 (711.5)
Feed Kit Shown Installed (Cover Not Shown)
25.00 (635.0) 18.69 (474.6) 2.00
1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2) Required
28.70 (729.0)
1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO
23.69 (601.8)
1.21
Sealing Provision
1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO
Bottom Endwall Direct Feed Kit Grade Level
Figure 6-12. Mobile Home Panel — Ringless Security — Back-to-Back Mounting CA08101001E
For more information visit: www.eaton.com
6-18
Power Outlet Panels February 2007
Product Selection
5.31 (134.8)
14.45 Ring Type Socket Rated 200 A Continuous
5/16 (7.9) Diameter KO Opposite Side Only
6
200A Main Breaker
1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1,
1, 1-1/4, 1-1/2, 2 (25.4,
Knockout
50.8) KO
ON
Door Not Shown OFF
5.56 (141.3)
57.81 (1468.3)
50.08 (1272.1) 43.20 (1097.4)
Optional Direct Feed Kit Shown Installed (Cover Not Shown)
1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2 Required)
1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO
28.70 (729.0)
28.01 (711.5)
27.87 (708.0)
24.64 (626.0)
23.69 (601.8)
Direct Feed Kit Sealing Provision
2.00 (50.8)
1.21 (30.7)
Grade Level
Figure 6-13. Mobile Home Panel — Ring Security — Pedestal Mounting Front View
Back View 11.25 (285.8)
10 75
14.45 (367.0)
200A Main Breaker
5/16 (7.9) Diameter KO 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout
Ring Type Socket Rated 200 A Continuous
57.81 (1468.3)
Door Not Shown
1-1/4, 1-1/2, 2, 2-1/2 KO (2) Required 3/4, 1 (19.1, 25.4) KO
1/2 (12.7) KO (3) Required
5/16 (7.9) Diameter
50.0 (1272 43.20 (1097.4) 27.87 (708.0)
22.01 (711.5)
Feed Kit Shown Installed (Cover Not Shown)
Bottom Endwall Back Unit
28.70 (729.0)
25.00 (635.0)
23.69 (601.8)
18.69 (474.6)
, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO
KO (2) Required
1/2, 3/4, 1 19.1, 25.4) K (2) Required
1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO
Grade Level Sealing Provision
Direct Feed Kit
Figure 6-14. Mobile Home Panel — Ring Security — Back-to-Back Mounting For more information visit: www.eaton.com
CA08101001E
Power Outlet Panels
6-19
February 2007
Product Selection
Mobile Home Panel Deadfronts for 200 Ampere Units
6
Figure 6-15. Available Receptacle Deadfront Kits — Receptacles and Breakers Not Included
For 100 ampere units, the accessory Catalog Number would be MHD1___. For example, to order a deadfront to accept one 30 ampere receptacle (round) in a 100 ampere device, the Catalog Number would be MHD1X.
Cutler-Hammer is am federally registered trademark of Eaton Corporation. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL is a federally registered trademark of Underwriters Laboratories Inc.
CA08101001E
For more information visit: www.eaton.com
6-20
Power Outlet Panels February 2007
This page intentionally left blank.
6
For more information visit: www.eaton.com
CA08101001E