Page

Power Outlet Panels Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Outlet Panel Receptacle Configuration Rules . . . . . . . . . . . . . . . . Unmetered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metered Surface Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unmetered Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Metered Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unmetered Back-to-Back Pedestal Type. . . . . . . . . . . . . . . . . . . . . . . . . . . Metered Back-to-Back Pedestal Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories and Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mobile Home Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Receptacle Deadfront Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6-3 6-3 6-5 6-5 6-6 6-7 6-7 6-8 6-8 6-8 6-8 6-9 6-15 6-16 6-16

Don’t Give Up! If you don’t find the product you want in this catalog, try the Flex Center at 1-800-330-6479.

Power Outlet Panel Family

CA08101001E

For more information visit: www.eaton.com

6


6-2

Power Outlet Panels February 2007

Product Description

Product Description A Power Outlet Panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. Construction sites and RV parks need to provide a safe and reliable means for users to access electricity and POPs provide the outlets for electrical access.

6

RV Park Application

Receptacles and Circuit Protection

When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of providing power to the vehicle’s appliances. Many RV parks now supply users with lighted POPs with TV and telephone jacks. A move towards offering more amenities at RV parks.

The circuit protection shall be Eaton’s Cutler-Hammer UL listed full-size Type BR or half-size Type BD circuit breakers. The receptacles shall be NEMA commercial/industrial grade and come in a wide variety of configurations. Ground fault protection (GFCB) shall be provided at the 20 ampere duplex NEMA 5-20R receptacle or 20 ampere single-pole circuit breaker when required. Ground fault protection shall be provided at the circuit breaker for receptacles above 20 amperes when required.

Application Description Power Outlet Panels or POPs are also sometimes called Temporary Power Panels, Temporary Site Service Equipment or RV Panels.

Construction

Construction Site Application When POPs are used at a construction site, they are installed on a temporary basis until electrical power is available at the building. The most common reason for needing a POP at a construction site is to provide a power source for the contractor’s tools.

RV Park Application

Standards and Certifications UL Standard 231. UL File Number E163588. ■ Receptacles conform to NEMA and/ or ANSI configurations as specified by the National Electrical Code . ■

Product Specifications

Construction Site Application

The power outlet panels shall be designed for outdoor service to meet temporary power outlet requirements at construction sites and provide high quality, economical power to individual sites at recreational vehicle (RV) parks. Construction site panels shall be provided with means to bond the neutral for service entrance applications. RV panels shall have a factory-installed insulated neutral bar.

For more information visit: www.eaton.com

The power outlet panel pedestal shall be of deadfront design and constructed of heavy gauge, 100 percent galvanized steel. Baked-on polyester powder coating shall be used for excellent mechanical strength, plus resistance to chalking caused by the sun’s ultraviolet rays. The power outlet panel surface and pedestal units shall have NEMA Type 3R rainproof enclosures.

Ease of Installation Panels shall ship from the factory completely assembled, prewired with 100 percent copper wire, and tested in accordance with UL Standard 231. Door shall swing up and open for user convenience and ease of access to breakers and receptacles. When required, a means for securing the door in the open position shall be provided. Panels shall be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Knockouts shall range from 1/2-inch (12.7 mm) to 1-1/2 inches (38.1 mm). #4 – 14 Cu/Al grounding provisions shall be provided on all panels.

Standard Compliance All power outlet panels for temporary construction site power and RV (recreational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E163588. Receptacles shall conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC).

CA08101001E


Power Outlet Panels

6-3

February 2007

Surface and Pedestal Units

Eaton’s Cutler-Hammer Power Outlet Panels Power Where You Need It, When You Need It Features ■ ■

■ ■

Designed for outdoor service to meet power outlet requirements. Receptacles conform to NEMA and/ or ANSI configurations as specified by NEC. Suitable for use as service entrance equipment. Includes a factory installed insulated neutral bar with provisions for bonding when used for service entrance applications. 125 ampere rated meter socket.

Designed for Easy Installation and Protection ■

Panels come from the factory completely assembled, prewired with 100 percent copper wire and tested...ready for easy installation. Door swings up and open for user convenience and ease of access to breakers and receptacles. Panels can be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Two-piece deadfront cover allows field wiring without interfering with factory wiring. Lower deadfront cover permits easy field wiring to circuit protective devices. GFI (ground fault interrupter) 1- and 2-pole protection through 50 amperes.

Two Styles to Meet Your Power Outlet Needs Surface Mount: User mounts unit to a post. Pedestal Mount: User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See accessories Page 6-15 for part numbers and options.)

Surface Units NEMA 3R construction for rainproof installation. 100 percent galvanized steel with baked-on polyester powder coating.

Utility grade metering available for construction site RV park applications.

Three-point mounting.

Door swings up and pushes in to lock into open position. Pull out and push down to close door.

One-piece case back for metered and unmetered panels. Lighted option for site location and nighttime panel operations. GFI circuit breakers available through 50 amperes. Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked.

• Metered units available with meter on top or on bottom.

Removable upper deadfront cover for easy incoming wire connections to breaker terminals.

Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts. Padlock provisions to prevent unauthorized entry.

• Units are factory wired and assembled.

Pedestal Units

NEMA 3R construction for rainproof installation.

100 percent galvanized steel with baked-on polyester powder coating.

Utility grade metering available for construction site RV park applications.

Door swings up and pushes in to lock into open position. Pull out and push down to close door. GFI circuit breakers (1- and 2-pole) available through 50 amperes.

One-piece case back for metered and unmetered panels.

Loop feed lug assembly with 350 kcmil lugs as standard.

Removable upper deadfront cover for easy incoming wire connections to breaker terminals. Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked. Lower deadfront cover rotates 90 degrees or can be removed for easy routing of incoming wires or receptacle changeouts. Padlock provisions to prevent unauthorized entry.

Pedestal extension available for underground services. Pad-mounted bracket option also available.

• Units are factory wired and assembled.

CA08101001E

For more information visit: www.eaton.com

6


6-4

Power Outlet Panels February 2007

Surface and Pedestal Units

Cutler-Hammer Power Outlet Panels Surface Units

6

Unmetered Type

Metered Ring or Ringless Type

Metered Ring or Ringless Type Bottom Feed

Single Receptacle

Pedestal Units

Unmetered Type Metered Ring or Ringless Type

For more information visit: www.eaton.com

Back-to-Back Type

CA08101001E


Power Outlet Panels

6-5

February 2007

Product Selection

Product Selection ■

When quoting or selecting a Power Outlet Panel, the following questions should be answered:

Unmetered, Ring or Ringless Style. Number and types of receptacles (7 standard and 8 twist-lock options). ■ Standard or Ground Fault Breakers. ■

Surface, Pedestal or Back-to-Back Mounting. ■ Are any factory or field options required?

Table 6-1. Catalog Numbering System

CH M 1 N 7 N 4 N P X L TZ U Feed

Cutler-Hammer

U = Bottom Fed Blank = Top Fed

Metering Type U = Unmetered M = Metered-Ring R = Metered-Ringless Receptacle Type Left Position 1= 2= 3= 4= 5= 6= 7= Blank =

NEMA 14-50R NEMA 10-50R NEMA 14-30R NEMA TT-30R NEMA 6-20R2 NEMA 5-20R2 NEMA 5-20R2GFI No Receptacle

Receptacle Type Center Position 1 = NEMA 14-50R 2 = NEMA 10-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA 6-20R2 6 = NEMA 5-20R2 7 = NEMA 5-20R2GFI Blank = No Receptacle

Circuit Breaker Type Position 1

Receptacle Type Right Position 1= 2= 3= 4= 5= 6= 7=

NEMA 14-50R NEMA 10-50R NEMA 14-30R NEMA TT-30R NEMA 6-20R2 NEMA 5-20R2 NEMA 5-20R2GFI

Circuit Breaker Type Position 2 N = Non-Ground Fault G = Ground Fault

N = Non-Ground Fault G = Ground Fault

TZ = Factory Installed Pedestal Extension with Lay-in Ground Lug L = Lighted Interior X = Six Circuit Blank = Standard Four Circuit Mounting S = Surface P = Pedestal B = Back-to-Back Pedestal Circuit Breaker Type Position 3 N = Non-Ground Fault G = Ground Fault

For receptacle configurations, see Table 6-2. Only available with metered surface mount units.

Note: Twist-lock receptacles are not listed in the above chart as not all receptacle combinations are valid even though one can create a catalog number above. Contact Eaton for a quote on twist-lock and custom receptacle/breaker combinations.

Table 6-2. Receptacle Configuration 1

50 ampere, 125/250 volt 3-pole, 4-wire, NEMA 14-50R

5

2-pole 50 ampere breaker 2

50 ampere, 125/250 volt 2-pole, 3-wire, NEMA 10-50R

2-pole 20 ampere breaker 6

2-pole 50 ampere breaker 3

30 ampere, 125/250 volt 3-pole, 4-wire, NEMA 14-30R 2-pole 30 ampere breaker

4

20 ampere, 250 volt, 2-pole, 3-wire, NEMA 6-20R2

20 ampere, 125 volt, 2-pole, 3-wire, NEMA 5-20R2 1-pole 20 ampere breaker

7

20 ampere, 125 volt, 2-pole, 3-wire, NEMA 5-20R2GFI 1-pole 20 ampere breaker

30 ampere, 125 volt 2-pole, 3-wire, NEMA TT-30R 1-pole 30 ampere breaker

CA08101001E

For more information visit: www.eaton.com

6


Power Outlet Panels

6-6

February 2007

Product Selection

Product Selection Built to Order

Power Outlet Panel List Price Configurator Table 6-3. Base Price Description

Price U.S. $

Configure catalog number. ■ Calculate list price. ■ Lead-time: ❑ 3 days up to 15 units ❑ 10 days up to 50 units

6

Unmetered Surface Metered Surface Unmetered Pedestal Metered Pedestal Unmetered Back-to-Back Metered Back-to-Back

Power Outlet Panel Receptacle Configuration Rules

Note: Contact your local Eaton sales office for current pricing.

Four Receptacles/Unit

Table 6-4. Receptacle/Breaker Adders

All receptacles must be NEMA 5-20R and/or NEMA 5-20R2, surface mount only.

Three Receptacles/Unit ■

One or more of the receptacles must be NEMA 6-20R2, NEMA 5-20R2 or NEMA 5-20R2GFI. ■ NEMA 6-20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position. ■ If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA 6-20R2 a six-circuit interior must be added. ❑ Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position.

Two, One and Zero Receptacles/Unit ■

Any configuration.

Configuration

Description

Price U.S. $

1N 1G

NEMA 14-50R

with 2-Pole 50 Ampere Breaker with 2-Pole 50 Ampere GFI Breaker

2N 2G

NEMA 10-50R

with 2-Pole 50 Ampere Breaker with 2-Pole 50 Ampere GFI Breaker

3N 3G

NEMA 14-30R

with 2-Pole 30 Ampere Breaker with 2-Pole 30 Ampere GFI Breaker

4N 4G

NEMA TT-30R

with 1-Pole 30 Ampere Breaker with 1-Pole 30 Ampere GFI Breaker

5N 5G

NEMA 6-20R2

with 2-Pole 20 Ampere Breaker with 2-Pole 20 Ampere GFI Breaker

6N 6G

NEMA 5-20R2

with 1-Pole 20 Ampere Breaker with 1-Pole 20 Ampere GFI Breaker

7N

NEMA 5-20R2GFI

with 1-Pole 20 Ampere Breaker

Note: Contact your local Eaton sales office for current pricing.

Table 6-5. Options Option

Price U.S. $

Six Circuit Interior Factory-Mounted Pedestal Extension Lighted Bottom Fed

Note: Contact your local Eaton sales office for current pricing.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-7

February 2007

Product Selection

Product Selection (Continued) Table 6-6. Surface Type Ampere Series

Receptacle Description

Breaker Description

Position

1st

2nd

3rd

UPC Number 78211

Catalog Number

Left

Center

Right

Price U.S. $

Unmetered Single Receptacle 50 50 30 30

— — — —

14-50R 10-50R 14-30 R TT-30R

— — — —

No Breaker No Breaker No Breaker No Breaker

No Breaker No Breaker No Breaker No Breaker

No Breaker No Breaker No Breaker No Breaker

6128174 6128181 6128198 6128204

CHU1S CHU2S CHU3S CHU4S

20 20 20

— — —

6-20R2 5-20R2 5-20R2GFI

— — —

No Breaker No Breaker No Breaker

No Breaker No Breaker No Breaker

No Breaker No Breaker No Breaker

6128211 6128228 6128235

CHU5S CHU6S CHU7S

20/20/20 20/20/20 20/20/20

5-20R2 5-20R2GFI 5-20R2GFI

5-20R2 5-20R2GFI 5-20R2GFI

6-20R2 6-20R2 6-20R2

GFI Non-GFI Non-GFI

GFI Non-GFI Non-GFI

GFI Non-GFI GFI

42039 2 42039 4 —

CHU6G6G5GS CHU7N7N5NS CHU7N7N5GS

50/20/30 50/20/30 30/20

5-20R2GFI 14-50R TT-30R

5-20R2GFI 5-20R2GFI 5-20R2GFI

TT-30R 6-20R —

Non-GFI GFI Non-GFI

Non-GFI Non-GFI Non-GFI

Non-GFI Non-GFI —

— — 42037 4

CHU1N7N4NS CHU1G7N7NS CHU4N7NS

20/20 50/20 50/20

5-20R2GFI 14-50R 14-50R

5-20R2GFI 5-20RGFI 5-20RGFI

— — —

Non-GFI GFI Non-GFI

Non-GFI Non-GFI Non-GFI

— — —

42037 7 42156 8 42037 0

CHU7N7NS CHU1G7NS CHU1N7NS

50/20/50 50 50/20

14-50R 14-50R 10-50R

5-20R2GFI — 5-20R2GFI

14-50R — —

Non-GFI Non-GFI GFI

Non-GFI — Non-GFI

Non-GFI — —

— — 42156 9

CHU1N7N1NSX CHU1NS CHU2G7NS

30/30/20 50/20 30

TT-30R 10-50R TT-30R 5-20R2

5-20R2GFI 5-20R2GFI — 5-20R2

TT-30R — — 5-20R2

Non-GFI Non-GFI Non-GFI GFI

Non-GFI Non-GFI — GFI

Non-GFI — — GFI

42039 0 42037 2 42036 7

CHU4N7N4NS CHU2N7NS CHU4NS CHU6G6G5GS6OM

Unmetered

Metered — Ring 50/20/20 20/20 20/20/20

14-50R 5-20R2GFI 5-20R2GFI

5-20R2GFI 5-20R2GFI 5-20R2GFI

5-20R2GFI — 6-20R2

GFI Non-GFI Non-GFI

Non-GFI Non-GFI Non-GFI

Non-GFI — GFI

42028 6 42028 3 42156 1

CHM1G7N7NS CHM7N7NS CHM7N7N5GS

20/20/20 50/30/20 50/20 20/20

5-20R2GFI 14-50R 14-50R 6-20R2

5-20R2GFI 5-20R2GFI 5-20R2GFI 5-20R2GFI

6-20R2 TT-30R — —

Non-GFI Non-GFI Non-GFI Non-GFI

Non-GFI Non-GFI Non-GFI Non-GFI

Non-GFI Non-GFI — —

42030 0 42028 8 42027 7 42156 3

CHM7N7N5NS CHM1N7N4NS CHM1N7NS CHM5N7NS

Metered — Ringless 50/20 20/20 50/20/20

14-50R 5-20R2GFI 14-50R

5-20R2GFI 5-20R2GFI 5-20R2GFI

— — 5-20R2GFI

GFI Non-GFI GFI

Non-GFI Non-GFI Non-GFI

— — Non-GFI

42190 7 42032 9 42398 3

CHR1G7NS CHR7N7NS CHR1G7N7NS

50/20 50/20 20/20/20

10-50R 14-50R 5-20R2GFI

5-20R2GFI 5-20R2GFI 5-20R2GFI

— — 5-20R2GFI

GFI Non-GFI Non-GFI

Non-GFI Non-GFI Non-GFI

— — Non-GFI

42398 2 42032 4 42034 7

CHR2G7NS CHR1N7NS CHR7N7N7NS

30/20/20 50/30/20

14-30R 14-50R

5-20R2GFI 5-20R2GFI

5-20R2GFI TT-30R

Non-GFI Non-GFI

Non-GFI Non-GFI

Non-GFI Non-GFI

42034 1 42033 4

CHR3N7N7NS CHR1N7N4NS

5-20R2GFI 5-20R2GFI 5-20R2GFI

— 6-20R2 5-20R2GFI

Non-GFI Non-GFI GFI

Non-GFI Non-GFI Non-GFI

— GFI Non-GFI

615327 5 615330 5 615329 9

CHM7N7NSU CHM7N7N5GSU CHM1G7N7NSU

Metered — Ring — Bottom Fed 20/20 20/20/20 50/20/20

5-20R2GFI 5-20R2GFI 14-50R

Metered — Ringless — Bottom Fed 20/20 50/20 50/20

5-20R2GFI 14-50R 10-50R

5-20R2GFI 5-20R2GFI 5-20R2GFI

— — —

Non-GFI GFI GFI

Non-GFI Non-GFI Non-GFI

— — —

615326 8 615328 2 615338 1

CHR7N7NSU CHR1G7NSU CHR2G7NSU

20/20/20 20/20/20 20/20/20

5-20R2GFI 5-20R2GFI 5-20R2GFI

5-20R2GFI 5-20R2GFI 5-20R2GFI

6-20R2 6-20R2 5-20R2GFI

Non-GFI Non-GFI Non-GFI

Non-GFI Non-GFI Non-GFI

GFI Non-GFI Non-GFI

615331 2 615332 9 615337 4

CHR7N7N5GSU CHR7N7N5NSU CHR7N7N7NSU

30/20/20 30/20/20 50/20/20 50/20/30

14-30R 14-30R 14-50R 14-50R

5-20R2GFI 5-20R2GFI 5-20R2GFI 5-20R2GFI

5-20R2GFI 5-20R2GFI 5-20R2GFI TT-30R

Non-GFI GFI GFI Non-GFI

Non-GFI Non-GFI Non-GFI Non-GFI

Non-GFI Non-GFI Non-GFI Non-GFI

615333 6 615334 3 615336 7 615335 0

CHR3N7N7NSU CHR3G7N7NSU CHR1G7N7NSU CHR1N7N4NSU

Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson. The “X” suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior. Includes 60 ampere 2-pole main breaker for service disconnect ratings. Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson. Note: Contact your local Eaton sales office for configurations not listed.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 22CD CA08101001E

For more information visit: www.eaton.com

6


Power Outlet Panels

6-8

February 2007

Product Selection Table 6-7. Pedestal Type Ampere Series

Receptacle Description

Breaker Description

Position

1st

2nd

3rd

UPC Number 78211

Catalog Number

Left

Center

Right

50/30/20 30/20

14-50R TT-30R

5-20R2GFI 5-20R2GFI

TT-30R —

Non-GFI Non-GFI

Non-GFI Non-GFI

Non-GFI —

42038 2 42031 7

CHU1N7N4NP CHU4N7NP

50/30/20 30/30/20

14-50R TT-30R

5-20R2GFI 5-20R2GFI

TT-30R TT-30R

Non-GFI Non-GFI

Non-GFI Non-GFI

Non-GFI Non-GFI

42038 3 42032 1

CHU1N7N4NPTZ CHU4N7N4NP

5-20R2GFI 5-20R2GFI

TT-30R —

Non-GFI Non-GFI

Non-GFI Non-GFI

Non-GFI —

42030 4 42231 5

CHM1N7N4NP CHM1N7NP

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

42031 0

CHR1N7N4NP

Price U.S. $

Unmetered

Metered — Ring

6

50/30/20 50/20

14-50R 14-50R

Metered — Ringless 50/30/20

14-50R

Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson. Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson. Note: Contact your local Eaton sales office for configurations not listed.

Table 6-8. Back-to-Back Pedestal Type Ampere Series

Receptacle Description

Breaker Description

Position

1st

2nd

3rd

UPC Number 78211

Catalog Number

Left

Center

Right

TT-30R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

42036 4

CHU4N7N4NB

5-20R2GFI 5-20R2GFI

— TT-30R

Non-GFI Non-GFI

Non-GFI Non-GFI

— Non-GFI

42034 8 42035 0

CHM4N7NB CHM1N7N4NB

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

42035 7

CHR1N7N4NBTZ

Price U.S. $

Unmetered 30/30/20

Metered — Ring 30/20 50/30/20

TT-30R 14-50R

Metered — Ringless 50/30/20

14-50R

Consult Power Outlet Estimator on Eaton’s intranet for additional combinations. Contact your local Eaton salesperson. The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs. Note: For receptacle and circuit breaker configurations, please contact your local Eaton salesperson. Note: Contact your local Eaton sales office for configurations not listed.

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-9

February 2007

Product Selection

Dimensional Drawings

6.58 (167.1)

0.24 (6.1)

2.63 (66.8)

6

7.10 (108.3) 4.50 (114.3)

3.18 (80.8) 1.30 (33.0) 2.50 (63.5)

1.87 (47.5 )

6.23 (158.2)

4.79 (121.7) 4.27 (108.5)

0.13 (3.3)

Figure 6-1. Single Receptacle CA08101001E

For more information visit: www.eaton.com


6-10

Power Outlet Panels February 2007

Product Selection

Ringless U.G. Feed Pedestal-Mount B/B

6

Hit Exit Hole B/B Only

18.02 (457.7)

8.25

33.00 (838.2)

33.00 (838.2)

Figure 6-2. 100 Amperes Back-to-Back

For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-11

February 2007

Product Selection

Ringless U.G. Feed Pedestal-Mount.

.79 (20.1)

6 0.24 260.0)

10.78 (273.7)

Gasket .92 (23.4)

4.00

Hit Exit Hole B/B Only

6.10 (154.9)

18.02

wer Barrier

33.00 (838.2)

Figure 6-3. 100 Ampere Pedestal CA08101001E

For more information visit: www.eaton.com

33.00 (838.2)


6-12

Power Outlet Panels February 2007

Product Selection

Dimensions in Inches (mm) — Metered Units (Ring and Ringless) 4.50 (114.3) 4.30

9.50

.07

6

30.00 (762.0) 22.50 (571.5) Locking Provision

Sealing Provision

(170.1)

Figure 6-4. Metered Surface Type

9.50 (241.3)

5.00 (127.0)

52.00 (1320.8)

6.80 (172.7) 4.30 (109.2)

Locking Provision

44.50 (1130.3)

25.80 (655.3)

22.00 (558.8) 16.90 (429.3)

Sealing Provision

Figure 6-5. Metered Pedestal Type For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-13

February 2007

Product Selection

Dimensions in Inches (mm) — Metered Units (Ring and Ringless)

6

Figure 6-6. Metered Back-to-Back Pedestal Type 6.80 (172.8) 4.31

9.49 (241.1)

.06 (1.6)

Locking Provision

30.10 (764.6)

17.11 (434.7) 12.97 (329.4) 6.15 (156.2)

Sealing Provision

Figure 6-7. Bottom Fed Type CA08101001E

For more information visit: www.eaton.com

4.93 (125.2)


6-14

Power Outlet Panels February 2007

Product Selection

Dimensions in Inches (mm) — Unmetered Units 9.50 (241.3)

4.30 (109.2) .07 (1.7)

6

17.10 (434.3)

14.50 (368.3) Locking Provision

1.30 (33.0)

6.70 (170.2)

Figure 6-8. Unmetered Surface Type 9.50 (241.3)

13.60 (345.4) 8.60 (218.4)

9.50

Locking Provision 17.10 (434.3) 39.10 (993.1) 39.90 (1013.5)

19.20 (487.7)

9.20 (233.7) 9.40 (238.8)

Figure 6-9. Unmetered Pedestal Type

.75 (19.1)

3.30 (83.8)

Figure 6-10. Unmetered Back-to-Back Pedestal Type

For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-15

February 2007

Accessories and Replacement Parts

Accessories and Replacement Parts Table 6-9. Accessories and Replacement Parts Description

UPC Catalog Number Number 78211

Price U.S. $

Pad-Mount Bracket

Accessories Underground Pedestal Extension Stainless Steel Underground Pedestal Extension Pad-Mount Bracket

420273 422130 420274

CHPEDEXT CHPEDEXTSS CHPADEXT

Cable TV and Telephone Bracket

420275

CHTELTV

Rainproof Conduit Hub 0.75 inch (19.1 mm) Rainproof Conduit Hub 1.00 inch (25.4 mm) Rainproof Conduit Hub 1.25 inch (31.8 mm) Rainproof Conduit Hub 1.50 inch (38.1 mm)

310991 310992 310993 310994

DS075H1 DS100H1 DS125H1 DS150H1

Fluorescent Light Kit — Converts power outlet panel to lighted unit, must also order CHOUTCVRL.

463424

CHFLGTKIT

Replacement Meter Socket Replacement Meter Socket Replacement Meter Socket (1 Block Assembly Per Kit)

481999 612728 603686

CHPOPMS CHPOPMSN ARP00039CH

5th Jaw Kit 5th Jaw Kit Bonding Strap and Mounting Hardware Horn Bypass (1 Lug Cap Per Kit; 4 Kits Required Per Device) Horn Bypass (1 Kit Required Per Device)

600788 400413 421926 612840 438033

1MM5JKOP ARP00035CHJ CHBONDST ARP00777CH 1MMBPH

Inner Lens for Lighted Power Outlet Panels Loop Feed Lug Assembly for Single Pedestal Loop Feed Lug Assembly for Back-to-Back Pedestal

421927 421928 421929

CHINLENS CHLOOPFDP CHLOOPFDB

Blank Lower Deadfront Cover Lower Deadfront Cover with Duplex Receptacle Opening Lower Deadfront Cover with Duplex, Duplex Receptacle Opening

421930 421931 421932

CHLDFCVR CHLDFCVR1 CHLDFCVR2

421933 421934

CHLDFCVR3 CHLDFCVR4

421935

CHLDFCVR5

DS Hub Underground Pedestal Extension Inner Lens

Replacement Parts

Lower Deadfront Cover with Duplex, Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Rectangle Receptacle Opening Lower Deadfront Cover with Rectangle, Rectangle Receptacle Opening

Lower Deadfront Cover with Rectangle, Rectangle, Rectangle Receptacle Opening 421936 Lower Deadfront Cover with Duplex, Rectangle Receptacle Opening 421937 Lower Deadfront Cover with Duplex, Rectangle, Duplex Receptacle Opening 421938 Lower Deadfront Cover with Rectangle, Rectangle, Duplex Receptacle Opening Lower Deadfront Cover with Round Receptacle Opening Lower Deadfront Cover with Round, Round Receptacle Opening Lower Deadfront Cover with Round, Duplex Receptacle Opening Lower Deadfront Cover with Round, Duplex, Duplex Receptacle Opening Lower Deadfront Cover with Round, Duplex, Round Receptacle Opening

CHLDFCVR6 CHLDFCVR7

421939 421940 422128

CHLDFCVR9 CHLDFCVR10 CHLDFCVR11

422129

CHLDFCVR12

421942

CHLDFCVR13 CHLDFCVR14 CHLDFCVR15

CHLDFCVR18 CHUDFCVR CHUDFCVRL

Power Head Outer Cover Power Head Outer Cover with Lens

421949 421950

CHOUTCVR CHOUTCVRL

6-Hole Neutral Assembly with 2/0 Lug 7-Hole Neutral Assembly with 2/0 Lug 5-Hole Ground Bar Kit 10-Hole Ground Bar Kit

421951 422180 309906 401456

CHNEUT CHNEUT1 GBK5 GBK10

Replacement Meter Cover — Ring Type Replacement Meter Cover — Ringless Replacement Meter Cover — Ringless Replacement Meter Cover — Ringless

483847 483848 612729 641914

CHPOPRMC CHPOPRLMC CHPOPRLMCN CHPOPRLMCN2

For Power Outlet Panels manufactured before 12/1/02. For Power Outlet Panels manufactured after 12/1/02. For Power Outlet Panels with a date code ending in L. For Power Outlet Panels with a date code not ending in L.

CA08101001E

Power Head Outer Cover

Loop Feed Lug Assembly

CHLDFCVR17

422079 421947 421948

Neutral Assemblies

CHLDFCVR16

Lower Deadfront Cover with Round, Rectangle, Duplex Receptacle Opening Upper Deadfront Cover with Six Breaker Twistouts Upper Deadfront Cover with Provisions for Lighted Option

Power Head Outer Cover with Lens

Meter Socket 421943

Cable TV/ Telephone Bracket

CHLDFCVR8

Lower Deadfront Cover with Round, Rectangle Receptacle Opening 421944 Lower Deadfront Cover with Round, Rectangle, Rectangle Receptacle Opening 421945 Lower Deadfront Cover with Round, Rectangle, Round Receptacle Opening 421946

6

For more information visit: www.eaton.com

Lower Deadfront Cover

Upper Deadfront Cover

Bonding Strap and Mounting Hardware Circuit Breaker (BR/GFCB)

Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . 22CD


Power Outlet Panels

6-16

February 2007

Product Selection

Mobile Home Panels The versatile Cutler-Hammer Mobile Home Panels have a user-friendly design that allows for a faster, cleaner installation — letting you move on to your next job sooner.

6

100 and 200 ampere panels come complete with the main breaker and a 4/8 or 8/16 interior, respectively. The 200 ampere units are designed about 5 inches wider than other manufacturer’s panels to ensure plenty of room for wire bending and an easier wiring job.

Receptacle Deadfront Kits

Fastenerless Socket Design

200 ampere units include a new door. Optional receptacle deadfront kits can supply power for a variety of applications including:

■ ■ ■ ■ ■

Visiting RVs. Pool filters. Weed whackers. Air compressors. Anything else that requires power (receptacles and breakers supplied by contractor).

Makes failure a non-issue. No socket connections that overheat.

Pedestal Unit ■

Convenient and sturdy ground mounting. ■ Loop feed feature allows several units to be connected in series.

Easier, Better and Faster Installation ■

More wire bending and viewing room. ■ Additional circuits mean more flexibility.

Table 6-10. Mobile Home Panels Amperes

Security

Interior

Main

Branch Breakers

Mounting

Receptacles

UPC Number Catalog 78211 Number

100 100 100 100

Ring Ring Ringless Ringless

4/8 4/8 4/8 4/8

BR2100 BR2100 BR2100 BR2100

BR BR BR BR

Pedestal Back-to-Back Pedestal Back-to-Back

None None None None

498168 9 498169 6 498170 2 498171 9

MHM100P MHM100B MHR100P MHR100B

150 150 150 150

Ring Ring Ringless Ringless

8/16 8/16 8/16 8/16

BWH2150 BWH2150 BWH2150 BWH2150

BR BR BR BR

Pedestal Back-to-Back Pedestal Back-to-Back

None None None None

617535 2 617534 5 616475 2 616474 5

MHM150P MHM150B MHR150P MHR150B

200 200 200 200

Ring Ring Ringless Ringless

8/16 8/16 8/16 8/16

BWH2200 BWH2200 BWH2200 BWH2200

BR BR BR BR

Pedestal Back-to-Back Pedestal Back-to-Back

None None None None

498172 6 498173 3 498174 0 498175 7

MHM200P MHM200B MHR200P MHR200B

200

Ringless

8/16

BWH2200

BR

Pedestal

Qty 1 14-50R Qty 2 TT-30R

498176 4

MHM200P1N4N4N

Price U.S. $

Pedestal Extension included with Mobile Home Panels.

For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-17

Product Selection February 2007

Product Selection

Ringless Socket Rated 200 A Continuous 5.31

Sealin 5/16 (7.9) Diameter KO Opposite Side Only

6

1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) Knockout

57.81 (1468.3)

200A

50.08 (1272.1) Optional Direct Feed Kit Shown Installed (Cover Not Shown) 27.87 (708.0)

28.01 (711.5)

43.20 (1097.4)

28.70 (729.0)

24.65 (626.1)

2.00 (50.8)

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO

1/2, 3/4,1 (12.7, 19.1, 25.4) KO (2 Required)

23.69 (601.8)

1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO

Sealing Provision 1.21

Grade Level

Figure 6-11. Mobile Home Panel — Ringless Security — Pedestal Mounting Front View

Back View

12.09 (307.2)

Ringless Socket Rated 200 A Continuous 10

14.45

1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) KO (2) Required Sealing Provision 57.81 (1468.3) Door Not Shown

5/16 (7.9) Diameter

Door Not Shown

Side Only

1,1-1/4, 1-1/2, 2

1-1/4, 1-1/2,

Diameter KO

(31.8, 38.1, 50.8, 63.5) Knockout

Side Only

1/2 (12.7) KO (3) Required 3/4, 1 (19.1, 25.4) KO KO (3) Required

200A Main KO (2) Required

1-1/2, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO

Bottom Endwall Back Unit

50.08 (1272.1)

(1097.4)

27.87 (708.0)

22.01 (711.5)

Feed Kit Shown Installed (Cover Not Shown)

25.00 (635.0) 18.69 (474.6) 2.00

1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2) Required

28.70 (729.0)

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO

23.69 (601.8)

1.21

Sealing Provision

1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO

Bottom Endwall Direct Feed Kit Grade Level

Figure 6-12. Mobile Home Panel — Ringless Security — Back-to-Back Mounting CA08101001E

For more information visit: www.eaton.com


6-18

Power Outlet Panels February 2007

Product Selection

5.31 (134.8)

14.45 Ring Type Socket Rated 200 A Continuous

5/16 (7.9) Diameter KO Opposite Side Only

6

200A Main Breaker

1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1,

1, 1-1/4, 1-1/2, 2 (25.4,

Knockout

50.8) KO

ON

Door Not Shown OFF

5.56 (141.3)

57.81 (1468.3)

50.08 (1272.1) 43.20 (1097.4)

Optional Direct Feed Kit Shown Installed (Cover Not Shown)

1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2 Required)

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO

28.70 (729.0)

28.01 (711.5)

27.87 (708.0)

24.64 (626.0)

23.69 (601.8)

Direct Feed Kit Sealing Provision

2.00 (50.8)

1.21 (30.7)

Grade Level

Figure 6-13. Mobile Home Panel — Ring Security — Pedestal Mounting Front View

Back View 11.25 (285.8)

10 75

14.45 (367.0)

200A Main Breaker

5/16 (7.9) Diameter KO 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout

Ring Type Socket Rated 200 A Continuous

57.81 (1468.3)

Door Not Shown

1-1/4, 1-1/2, 2, 2-1/2 KO (2) Required 3/4, 1 (19.1, 25.4) KO

1/2 (12.7) KO (3) Required

5/16 (7.9) Diameter

50.0 (1272 43.20 (1097.4) 27.87 (708.0)

22.01 (711.5)

Feed Kit Shown Installed (Cover Not Shown)

Bottom Endwall Back Unit

28.70 (729.0)

25.00 (635.0)

23.69 (601.8)

18.69 (474.6)

, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO

KO (2) Required

1/2, 3/4, 1 19.1, 25.4) K (2) Required

1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO

Grade Level Sealing Provision

Direct Feed Kit

Figure 6-14. Mobile Home Panel — Ring Security — Back-to-Back Mounting For more information visit: www.eaton.com

CA08101001E


Power Outlet Panels

6-19

February 2007

Product Selection

Mobile Home Panel Deadfronts for 200 Ampere Units

6

Figure 6-15. Available Receptacle Deadfront Kits — Receptacles and Breakers Not Included

For 100 ampere units, the accessory Catalog Number would be MHD1___. For example, to order a deadfront to accept one 30 ampere receptacle (round) in a 100 ampere device, the Catalog Number would be MHD1X.

Cutler-Hammer is am federally registered trademark of Eaton Corporation. National Electrical Code and NEC are registered trademarks of the National Fire Protection Association, Quincy, Mass. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. UL is a federally registered trademark of Underwriters Laboratories Inc.

CA08101001E

For more information visit: www.eaton.com


6-20

Power Outlet Panels February 2007

This page intentionally left blank.

6

For more information visit: www.eaton.com

CA08101001E


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.