i3Hawm UniE
21-11-2013
Mounting instructions
1. INDEX
2
1.
Index
2.
Important safety instructions
3.
Maximum loads
5
4.
Different configuraties
6
5.
Part list/Installation on Stud wall
7
6.
Preparing frame
8
7.
Installation on solid wall
12
8.
Installation on Stud wall
13 - 14
9.
Installation board
15 - 17
10.
General mounting positions
18 - 20
11.
Important safety instructions
12.
Additional items
13.
Preparing frame Interwrite boards
23 - 24
14.
Use of universal brackets
25 - 26
15.
Use of adapterplate
HL-HAWM UniE-0001-1-12-13B
2 3 -4
3 - 4 - 21 22
27
2. Important safety instructions: Instruct all users of the board!
Never place any object under the board
For safety reasons ,the board must be able to reach its lowest position at all times. Note that when the HAWM-uniE system re-initialises itself,it will run all the way down to its lowest possible 1
2
position.
”Safety settings” Refer to the document “Safety instructions” to set “anti-collision”,”stroke-lenght” and “initialisation time” of the system.
i3HAWM Height adjustable wall-mount Universal Electric
3
Installation This installation is intented to be executed by qualified personnel only. 2 persons are needed to do the job. Depending on local circumstances (wall conditions etc), it may be necessary to substitute the supplied “general purpose� hardware. Installers must be familiar with mechanical construction and electronic installations.
Check this first!
Locally acuire matching power chord (c13 or c14 connector)
4
HL-HAWM UniE-0001-1-12-13B
3. Max. loads
Distance
m1
m2
Usage: duty cycle 10% 6min per hour or 2 min continuous at full load.
Actuator
1200 N
Range (adjustable)
650 mm
Power supply
230 V/50Hz
r max.
1200 mm
m1 (r<600mm)
max. 15 kg
max. 33 lbs
m1 (r>600mm)
max. 12 kg
max. 26 lbs
m2
max. 80 kg
max. 176 lbs
m1 + m2
max. 95 kg
max. 209 lbs
i3HAWM Height adjustable wall-mount Universal Electric
5
4. Different configurations See drilling instructions that can be downloaded from
http://www.vsvint.be/vsv/hawm-templates
5. PART LIST 101234 Hawm UniE for solid walls Part List Id
V G Number
Q
Description
3.1
BS/A44200X
1
Frame RAL7021
3.2
BS/L45100X
2
Wall Mount adapter profile vertical
3.3
BS/L45200X
2
Wall Mount adapter profile horizontal
1
Power cable
info
Hardware Bag/List (BS/A446010 - frame HAWM-UniE) (1/5)
6
Id
V G Number
Q
Description
3.4
22/050783
6
Cable protection
3.5
23/040332
4
Plug 10
3.6
23/040188
4
Lag bolt hex head 8x80
3.7
23/090273
4
Flange nut M5
3.8
23/040440
4
Screw pan head cross M5x40
3.9
23/090275
4
Flange nut M6
3.10
23/090382
4
Screw pan head cross M6x30
3.11
07/050546
4
Anti loss washer
23/040302
2
Plug 6x30
fixation control cable
23/040179
2
Screw countersunk head cross 4x40
fixation control cable
3.11
00/080004
4
Cable tie
fixation cables
3.12
23/090411
2
Self drilling screw 4,2 x 32
HL-HAWM UniE-0001-1-12-13B
info
i3HAWM Height adjustable wall-mount Universal Electric
7
6. preparing frame Place the frame horizontally Drill the holes in the upperplate, (checklist configurations) using the appropriate template Pre-install all the cables (power,VGA etc) Mount the support of the projector with: Hardware Bag (type A)/List (BS/A451010 - Projectorplate) Id
V G Number
Q
Description
A.1
23/040192
4
Screw pan head crossM6x40
A.2
23/090275
4
Flange nut M6
info
example: NEC upperplate
8
HL-HAWM UniE-0001-1-12-13B
In case of white boards and i3BOARD: install the (aluminium) board’s adapter bracket (supplied with the board) to the wall mount’s adapter profile.
Hardware Bag (type B)/List (BS/A461010 - VBL-SOLUTION - i3BOARD) Id
V G Number
Q
Description
B.1
23/090386
4
Screw pan head cross M6x10
B.2
23/090275
6
Flange nut M6
B.3
23/040347
2
Screw pan head cross M6x16
info
Install the wall mount’s adapter profile to the frame. First the vertical ones. See page 11 for bolt positions.
i3HAWM Height adjustable wall-mount Universal Electric
9
For SMART boards mount the plastic bracket against the upper horizontal wall mountâ&#x20AC;&#x2122;s adapter profile
Support SB
Hardware Bag (type C)/List (BS/A471010 - SMART) Id
10
V G Number
Q
Description
C.1
23/050968
3
Screw pan head cross M5x20
C.2
23/090273
3
Flange nut M5
C.3
23/090296
2
Hex socket button head 1/4-20x/0.625
C.4
07/050546
2
Anti loss washer
HL-HAWM UniE-0001-1-12-13B
info
Bolt positions for fixing Wall mountâ&#x20AC;&#x2122;s adapter profile to the frame FRONT
960
310
343
262
880-885i add-on 680-685i add-on
54 10
A B
208 181 157 140 122 100
SIDE 1 2 3 4 5 6 7 8 9
i3 add-on i3
880-885i add-on 680-685i add-on C
i3 add-on i3
D
E
i3HAWM Height adjustable wall-mount Universal Electric
11
7. Installation on solid wall Mount the frame against the wall minding the drilling pattern.(page 20)
STWL-KIT
Work subtle!
12
HL-HAWM UniE-0001-1-12-13B
8. Installation on Stud wall HAWM UniE + VSV0003437 mounting kit stud wall
Part list Id
V G Number
Q
Description
E.1
BS/L57400X
1
Support STWL-kit
E.2
BS/L57300X
2
Hook STWL-kit
info
Hardware Bag( type E)/List (BS/A576010 Stud Wall) Id
V G Number
Q
Description
E.3
23/090387
4
Toggler M6
info
E.4
23/040192
4
Screw pan head cross M6x40
E.5
23/040161
2
Screw pan head cross 4,8x16
E.6
23/090298
2
Screw pan head cross M6x10
E.7
23/090384
2
Hammer nut M6
i3HAWM Height adjustable wall-mount Universal Electric
13
Mounting the studwall-kit Drill 2 holes ø 13mm in the plasterwall and make sure that one of them is in a steel stud. (Holes in the profile are positioned 15mm lower than those in the frame)
100 200 300 400
Fix the support to the wall with the 2 TOGGLER plugs and screws. Hang the frame on the support. Drill 2 holes ø 13mm below the frame, see drawing, also one in a steel stud Fix the 2 brackets to the bottom of the frame using bolts and hammer nuts. Fix the brackets to the wall be using TOGGLER plugs and bolts.
Changeable
15
Drill 2 holes ø 4mm through the holes of the support in the frame and fix them with screws 4,8x19mm
14
HL-HAWM UniE-0001-1-12-13B
9. Installation board In case of ENO board, install their specific supports
TOP
BOTTOM
Hardware Bag (type D)/List (BS/A481010 - ENO) Id
V G Number
Q
Description
D.1
23/090385
6
Screw pan head cross M5x12
info
D.2
23/090273
6
Flange nut M5
i3HAWM Height adjustable wall-mount Universal Electric
15
Hang the board on the frame Fix the board. For SOLUTION and VBL boards: in the pen tray
For SMART boards: use the standard SMART inserts
For ENO boards: in the upper trim
16
HL-HAWM UniE-0001-1-12-13B
For i3BOARD 77” and 88”
Part list Id
V G Number
Q
Description
11
2
Spacer
7
1
Remote control
12
2
Washer
8
5
Bolts
1
2
Bolt M6 x 50 mm
2
2
M6 nut
3
2
M § nut (low)
info
i3HAWM Height adjustable wall-mount Universal Electric
17
10. General mounting positions
18
HL-HAWM UniE-0001-1-12-13B
500
‘distance B’ (min. ceiling hight)
650
‘distance A’ (drill patern)
2100 (ideal viewplane, highest position)
Mounting positions frame/wall (distance A / distance B in mm)
U250X i3 77” i3 87” Solution 4/3
U260W
I3*-2
UM280X
UM280W
I3*-7 I3*-2
475Wi & W
I3*-4
B.E-1
B.E-4 B.E-1
B.E-4
VBL624220
A.E-1
A.E-4
SB 480
B.D-9 B.C-2
SB 685 SB 880
Unifi 75
I3*-7
Solution 16/10
SB 680
V25
I3*-7
B.C-7 B.C-2
B.C-2
SB 885
B.C-7 B.C-4
B.C-7 B.C-2
B.C-8
B.C-7 B.C-4
B.C-8
B.C-7 B.C-8
B.C-7
Eno 2610 Eno 2620 Eno 2810 Eno2820 Vintage 4/3
I3-7
Vintage 16/10
I3-7 I3-4
I3-7
Mounting positions frame/wall (distance A/ distance B in mm) U250X i3 77” i3 87” Solution 4/3
U260W
1900/2730
UM280X
UM280W
1770/2600 1900/2730
475Wi & W
1840/2670
1900/2730
1790/2620 1900/2730
1790/2620
VBL624220
1900/2730
1740/2570
SB 480
1720/2550 1900/2730
SB 685 SB 880 SB 885
Unifi 75
1770/2600
Solution 16/10
SB 680
V25
1770/2600
1770/2600 1900/2730
1900/2730
1770/2600 1840/2650
1770/2600 1900/2730
1740/2570
1770/2600 1770/2600
1840/2650
1740/2570
1740/2570
1770/2600
Eno 2610 Eno 2620 Eno 2810 Eno2820 Vintage 4/3 Vintage 16/10
1760/2590
1770/2600 1830/2660
1770/2600
i3HAWM Height adjustable wall-mount Universal Electric
19
* I3 Add-on if add-on is ordered Unifi 75W
UF 70
UF 70 W
UX 60
UX 80
PJ 905
Lightraise 60 Wi
i3 2402W
B.E-3
B.C-8
B.C-8
B.C-6
B.C-8
B.C-8
B.C-6 B.E-7 B.E-4 B.E-7 B.E-4
I3-6
Unifi 75W
UF 70
UF 70 W
UX 60
UX 80
PJ 905
Lightraise 60 Wi
1820/2650
1740/2570
1740/2570
1800/2630
1740/2570
1740/2570
1800/2630 1770/2600 1790/2620 1770/2600 1790/2620
1820/2650
20
HL-HAWM UniE-0001-1-12-13B
i3 2402W
11. important safety intructions Secure the cables to frame with cable ties , allow a cable loop of >650mm. Protect cables with rubber sleeves. Make sure all cables enter/exit the frame through the cable guide openings.
Install the projector by following the installation guide of the projector This device is not intented to be used by persons (including children) with physical ,sensory or mental disabilities or lack of experience and/or knowledge,unless, they are supervised or received instructions on how to use the device. Children should be supervised to ensure that they do not play with the device Please keep this manual for later reference.
i3HAWM Height adjustable wall-mount Universal Electric
21
12. Additional items VSV0004309 blind fixing system for Interwrite boards VSV0004308 universal solution with adjustable supports (visible) VSV0004343 Adapterplate for projector SMART UX 60 Drilling templates for the projectors can be downloaded from
http://www.vsvint.be/vsv/hawm-templates
22
HL-HAWM UniE-0001-1-12-13B
13. Preparing frame interwrite boards VSV0004309 blind fixing system for Interwrite boards * Discard supplied Wall Mountâ&#x20AC;&#x2122;s adapter profiles.
i3HAWM Height adjustable wall-mount Universal Electric
23
Part list Id
V G Number
Q
Description
F.1
BS/L45000X
2
Wall Mount adapter profile vertical
F.2
B/M0202020
1
Wall support alu
info
Hardware Bag/List (BS/A501010) Id
V G Number
Q
Description
F.3
23/050968
2
Screw pan head cross M5x20
B.1
23/090386
3
Screw pan head cross M6x10
B.2
23/090275
3
Flange nut M6
info
Mount the wall support the same way as a white board. Pre-install the frame, see pages 8-9 , but use the adapter profiles for the INTERWRITE boards. Mount the frame against the wall. Fix the board.
24
HL-HAWM UniE-0001-1-12-13B
14. Use of universal brackets VSV0004308 universal solution with adjustable adapter support profiles (visible)
i3HAWM Height adjustable wall-mount Universal Electric
25
Part list Id
V G Number
Q
Description
G.1
BS/L46100X
2
Adjustable support under
G.2
BS/L46200X
2
Adjustable support up
info
Hardware Bag (type G)/List (BS/A491010)
26
Id
V G Number
Q
Description
G.3
23/090382
4
Screw pan head cross M6x30
G.4
23/090275
4
Flange nut M6
G.5
23/090385
4
Screw pan head cross M5x12
G.6
23/090273
4
Flange nut M5
HL-HAWM UniE-0001-1-12-13B
info
15. Use of adapterplate VSV0004343 Adapterplate for projector SMART UX 60
Adapterplate
(support UX60)
Part list
Id
V G Number
Q
Description
G.1
BS/H462020
1
Adapterplate
info
i3HAWM Height adjustable wall-mount Universal Electric
27
BELGIUM-LUXEMBOURG
NETHERLANDS
France
Nijverheidslaan 60
Duwboot 91
Parc d’activités de la Vallée
8540 Deerlijk
3991 CG Houten
de l’Escaut Waka 1, n° 9
Belgium
Netherlands
59264 Onnaing France
T +32 (0)56 313 415
T +31 (0)30 6379387
T +33 (0)3 27 45 60 60
F +32 (0)56 313 688
F +31 (0)30 2547927
F +33 (0)3 27 45 60 70
USA
Germany
SCANDINAVIA
549 Ionia Ave. SW
Lohrheidestraße 72
Lollandsvej 16
Grand Rapids, MI 49503
44866 Bochum
5500 Middelfart
USA
Germany
Danmark
T +616-451-7800
T +49 (0) 2327 960 50-0
T +45 64 41 04 90
F +616-451-9698
F +49 (0) 2327 960 50-50
F +45 64 41 17 47
Authorised reseller
www.i3-learNing.com info@i3-learNing.com