Trox quick selection guide

Page 1

Issue Date June 2009

Quick Selection Guide


Quick Selection

This selection guide has been designed to allow quick and simple selection for a broad range of TROX Grille and Diffuser product. Full product and system details for these and other TROX equipment can be found on our website www.troxuk.co.uk. As part of our commitment to a collaborative design process our local Sales Engineers are available to offer assistance and advice on these and other TROX systems and product. To contact you local engineer call 01842 754545. In addition to the Grille and Diffuser product in this guide, TROX offer a complete range of air distribution products and systems, these include: Active Chilled Beams Passive Chilled Beams Multi Service Chilled Beams (MSCB) Chilled Ceilings Fan Coil Units Acoustics Filtration VAV Terminal Units Labcontrol Dealer Desk Cooling Low to High Density Cooling

TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Tel: +44 (0) 1842 754545 Fax: +44 (0) 1842 763051 E-Mail: sales@troxuk.co.uk www.troxuk.co.uk


Contents

Page

Section1 - Adjustable Grilles AT/VAT

04

Section 2 - Extract Grille AE

06

Section 3 - Floor Grilles AFG FB

08 10

Section 4 - Linear Grilles AH/WAP/AF

12

Section 5 - Transfer Grilles AGS/LCG/LVV40

14

Section 6 - Slot Diffusers VSD50 - High Capacity VSD35 ALS-25 - High Capacity ALS-20 Slot Diffuser Plenum Boxes

16 18 20 22 24

Section 7 - Fixed Blade Linear Diffuser ADM

26

Section 8 - Louvre Faced Diffusers Square Diffuser ADT ADLQ Circular Diffuser ADLR

28 32 34

Section 9 - Perforated Face Diffuser ADLQL

36

Section 10 - Disc Valves LVS/ZLVS

38

Section 11 - Swirl Diffusers Selection Methodology SDW VDW FD DCS TDF TDV RFD

40 42 44 46 48 50 52 54

Section 12 - Jet Nozzles DUK AJA

56 58


SECTION 1

Adjustable Grille Type VAT Supply or return air grille with individually adjustable vertical aerofoil blades. Front border 32mm wide with visible screw fixing (border counter-punched). Available on request with concealed fixing and sub frame.

Adjustable Grilles

Adjustable Grille Type AT Supply or return air grille with individually adjustable horizontal aerofoil blades. Front border 32mm wide with visible screw fixing (border counter-punched). Available on request with concealed fixing and sub frame.

Sizes Available Minimum size 150 x 100. Maximum Size 1200 x 600. Standard increments 50mm. For full details see publication 1/1.1/B/...

Order Code AT - AG

/

800 x 200

/

B30

/

S11

L x H (mm)

Type AT = Horizontal front blade VAT = Vertical front blade

0 = No subframe

Rear Assemblies A = Grille face only

B30 = 75mm subframe bracket

AG = Rear opposed blade damper D

/

P3

/

/

RAL 9010

20% Gloss

Powder coat finish

Fixing Variant 0 = Without (screw fix) S11 = With (secret fix) X = Without flange drilling or secret fix

= Rear adjustable blades

DG = Rear adjustable blades and damper

Type AT 路 VAT

75 107

04

...-DG Volume control dampers as ...-AG plus a set of individually adjustable vertical air pattern control blades.

16,7

H + 45/L + 45

...-D A set of individually adjustable vertical air pattern control blades. For type VAT these blades are horizontal.

H + 22/L + 22

...-AG Opposed blade action volume control damper, adjustable from the front face.

H/L

32 64

75 107

Rear Assembly

Type AT shown


Grille with ceiling effect (grille installed within 300mm of ceiling). Throw is the distance from sidewall grille to an average velocity of 0.35 m/s. The minimum distance between multiple units must be 20% of Throw. Nominal width (mm) L

Air Volume (l/s)

1100

150

500

200

Nominal height (mm) H

100

700 600 400

Throw (m)

350

300

250

10 8

200

6

175

5

150

4

125

3

100 90

Effective Jet Velocity (m/s) 8

Pressure drop (total) (Pa)

250

60 40

6 5 4

300

20 10

3

350

5

2

400 450

Pivot line

70

500

50

600

40

700

30

800

20

900

150

200

250

Adjustable Grilles

1000 900 800

Pivot Line

SECTION 1

Performance Data

300 350 400 450 500 600

1000 1200

Throw assumes direction blades set at 45° blade divergence. For 0° blade divergence multiple throw by 1.4 and divide pressure drop by 1.1.

Subframe

By limiting effective jet velocity to 7 m/s all grille sizes shown meet NC35 assuming 8dB room attenuation and fully open damper.

Secret Fixing Detail 32

Concealed fastener factory fitted to grille border

L+6/H+6

‘X’

Type B30 - 30mm border : X = 15

15

75

Subframe fixed to surround (No 8 screw by others)

Screwdriver operation to locate fastener tongue behind subframe

05


SECTION 2

Eggcrate Grille Type AE Return air grille with fixed square pattern core. Front border 32mm with visible screw fixing. Available on request with concealed fixing. The grille is available with rear mounted opposed blade volume control damper adjustable from the front face.

Size Available Minimum Size 150 x 100. Maximum Size 1200 x 600. Standard increments 50mm.

Extract Grilles

For full details see publication 1/1.3/B/...

Order Code AE - AG

/

Type AE

200 x 200

Screw Fixing

/

S11

/

P3

L+6/H+6

Screwdriver operation to locate fastener tongue behind subframe

70 104

20% Gloss

Fixing Variant 0 = Without (screw fix) S11 = With (secret fix) X = Without flange drilling or secret fix

Subframe Subframe fixed to surround (No 8 screw by others)

32

75

15

13 H + 22/L + 22 H + 45/L + 45

/

RAL 9010

Secret Fixing Detail

Rear Assembly

...-AG

/

Powder coat finish

Subframe 0 = without subframe B30 = 75mm subframe bracket

Concealed fastener factory fitted to grille border

H/L

B30

L x H (mm)

Rear Assemblies A = Grille face only AG = Rear opposed blade damper

06

/

‘X’

Type B30 - 30mm border : X = 15


Nominal width (mm) L 200

1000

500 400 300 200

100

50

25

300

Effective Jet Velocity (m/s) 7 6 5 4 3 2 1 0.5

Pivot line

Pressure drop (total) (Pa) 15 10 5 2

Nominal height (mm) H

100

150

200 400

500

600 700 800 900

250

Extract Grilles

Air Volume (l/s)

Pivot line

SECTION 2

Performance Data

300 350 400 450 500 600

1000 1100

1200

By limiting effective jet velocity to 7 m/s all grille sizes shown meet NC35 assuming 8 dB room attenuation (no damper or damper fully open).

07


SECTION 3

Computer Room Floor Grille Type CFG/AFG Floor grille types CFG and AFG are specifically developed for mounting in Raised Access Floors in such areas as Computer Rooms, where load and damage resistance are of the utmost importance. Having a heavy duty construction, they can replace 600mm square floor tiles. Grille border depth can be specified to suit the type of floor system used. A range of surface finishes is available. The type CFG is a fan assisted computer room floor grille that eliminates hotspots and reduces risk of equipment failure by providing up to 5kW of cooling per cabinet.

Floor Grilles

The type AFG is a static grille assembly which can handle supply air or alternatively extract air and be fitted with rear opposed blade damper assembly for air volume flow control. For full details see publication PI/1/9/B/...

Order Code CFG - F1

/

600 x 600

/

125

Size (mm)

Type CFG AFG

Unit Depth (mm) 125 = Standard *75 = Optional 0 = Not used AFG

Rear Assembles F1 = Fan Pack (230V Standard) CFG only A = Face only, AFG only AG = Rear opposed blade damper, AFG only

/

35

/

Frame Depth (mm) between face of grille and face of pedestal 25 standard Optionally 26 - 50 in 1mm steps

P2 P2

= Polyester powder coat silver grey RAL 9006 25% Gloss (Standard) P4 = Polyester powder coat black RAL 9006 20% Gloss N1 = Polyester powder coat with nylon reinforcing black RAL 9005

*Does not have the structural performance of 125mm unit

Type CFG

Type AFG

90mm Maximum Pedestal 599u +0.5/-1mm

125mm1)

13mm Nominal Pitch

Power Inlet Plug (C14) Note: 1) 75mm CFG depth option available

68.5

140mm Approx

X

Detail A

Shims to suit height required (factory fitted)

X standard 25mm. Can be 25-50mm in 1mm steps

08

6mm

Detail A


Watts/Motor Total Watts Amps/Motor Total Amps Motor 230V AC

CFG Acoustic Data 26 104 0.12 0.48 50Hz

Sound power level for one CFG 76dB(A) In an area with several units the noise level will increase due to multiple sources. To allow for this and room attenuation an assessment should be made by an acoustic engineer to ensure required room noise levels are achieved.

SECTION 3

CFG Fan Specification

Selection Guide

Structural performance

Potential cooling

The 125mm deep unit will provide the following strength against the performance specification:

6.00 5.11kW

PSA MOB PF2 PS/SPU March 1992, with the following results:

Result

Stability of deflection (centre of grille):

5.00

kW Cooling Capacity

Test

Floor Grilles

The floor grille should be located at the front of the I.T./Comms cabinet experiencing hot spot conditions the cabinet should incorporate a perforated door. The floor void static pressure must be considered in the selection process (see Potential cooling below). Sufficient void air (cooled by others) must be available to be drawn by the grille at the specific point of need.

4.00

3.00

2.00

Deflection 23 hours after load applied - 3mm Deflection 24 hours after load applied - 3mm 0.09mm permanent deformation 0.01mm permanent indentation

3 kN load 50 passes of wheel

CFG

AFG Grille (no fans)

Did not collapse 600 500

Dynamic rolling load test: 4.5 kN load 50 passes of wheel 3 kN load 50 passes of wheel

0.00

Note: Based on 10k rise across I.T. equipment with 1 Pascal floor void static pressure

Impact load test: 40 kg Sand Bag from 1m height

0.81kW

1.00

Did not collapse 0.40mm Vertical permanent deformation (max) 0.20mm Horizontal permanent deformation (max)

Air Volume (l/s)

4.5 kN static load through 25mm square indentor

400 300 200 100 0

Safety load test (centre of grille): 13.5 kN load through 25mm square indentor

-15

-10

-5

0

5

10

15

Floor Void Static Pressure (Pa) Did not collapse

CFG: 4 fans

AFG: no fans

09


SECTION 3

Floor Grille Type FB Floor Swirl Diffusers available in either aluminium or plastic construction in a range of finishes/colours. Diffusers may be installed into a floor with either a pressurised void (no plenum box) or duct connection to optional side entry plenum box. Air discharge pattern may be adjusted to provide either horizontal or vertical by adjustment of optional control element (not type VF).

Floor Grilles

For full details see publication 1/8/EN/...

Order Code - Aluminium Construction FBA - 1 - V - K - SM - A

/

150

Type Surface of diffuser core and trim ring: Die cast and deburred Die cast, deburred, tumble fettled Die cast, deburred, tumble fettled and polished black stove enamel paint, face skimmed natural Die cast, deburred, tumble fettled face skimmed

Size (mm) 150 200

1 2 3

A = Plenum box 4 SM = Dirt trap including adjustable volume control at rear SV = Dirt trap including adjustable volume control at face

Adjustable swirl element2) vertical V directional control horizontal H vertical - fixed VF3)

K = Trim ring1)

1)

For orders without trim ring a spacing ring is provided for technical performance reasons and to ensure correct height of grille core. For orders without adjustable swirl element the direction of air discharge is vertical. 3) Only available for size 200. 2)

Order Code - Plastic Construction FBK - 1 - V - K - SM - A

/

150

/

0

/

V00

Type Surface of diffuser, core and trim ring: Ash grey - similar to RAL 7037 Black - similar to RAL 9005

Size (mm) 150 200

1 2

0

= Standard polyamide (PA 6) V00 = Polyamide (PA 6-V0)

A = Plenum box

Adjustable swirl element2) vertical V directional control horizontal H vertical - fixed VF3)

SM = Dirt trap including adjustable volume control at rear SV = Dirt trap including adjustable volume control at face K = Trim ring1)

1)

For orders without trim ring a spacing ring is provided for technical performance reasons and to ensure correct height of grille core. For orders without adjustable swirl element the direction of air discharge is vertical. 3) Only available for size 200. 2)

1

2

3 4

5 6

10

1 2 3 4 5 6

Diffuser Core Swirl element for adjustment of air discharge direction Trim Ring Clamping Ring Dirt Trap Plenum Box


SECTION 3

Performance Data Horizontal Discharge Throw (m) 0.9 m 1.2 m 15 - 25 18 - 30 18 - 50 28 - 70 21 - 35 25 - 41 13 - 35 18 - 50

Size 0.3 m 10 - 16 8 - 20 16 - 27 8 - 20

Air Volume (l/s) min - max Press Drop (Pa) min - max Air Volume (l/s) min - max Press Drop (Pa) min - max

150 200

Vertical Discharge 1.5 m 30 - 50 28 - 70

10 - 30 5 - 35 10 - 50 5 - 50

Max noise level NC38 assuming 4dB room attenuation. Data for FBA diffusers and dirt trap, damper fully open no plenum box. Horizontal discharge is Throw distance to terminal velocity of 0.15m/s (min vol) and 0.25m/s (max vol). A 600mm clear zone (from centre of diffuser) is recommmended with vertical discharge.

Size 150 200

ØD 98 123

G 50 48

E 160 200

H1 125 150

H2 71.5 84

K1 200 250

K2 198.5 248.8

ØR1 149.5 199.5

ØR2 138 188

ØR3 137 187

ØR4 150.1 200.1

ØR5 150.3 200.3

c1 21 21

c2 22 22

Clamping ring For installation in floor panels - min. 25mm thickness

Diffuser core FBA/FBK ØR1 c1

21

Floor Grilles

Dimensions

ØR5

2

Adjustable swirl element to change direction of discharge Vertical/Horizontal (V,H)

Vertical - fixed (VF) Clamping ring For installation in floor panels - max. 55mm thickness

ØR2 E

2

2

ØR2

Dirt trap SM/SV

1,5

47

ØR3

Plenum box A 18

G

ØD

70

c2

H1

ØR4

4,5

24

K1/K2

H2

Trim ring K

ØR4-9,5

11


SECTION 4

Linear Grille Types AH - WAP Supply or return air grille with fixed horizontal profiled blades. Type AH - 5.5mm blades on 12.5mm pitch. WAP - 3mm blades on 12.5mm pitch. Front border 30mm wide, blades with either 0° or 15° deflection, Type AH-0 and AH-15 respectively, with visible screw fixing (border counter punched). Available on request with concealed fixing. Standard finish: Powder coated RAL9010 20% gloss.

Linear Grilles

Type AF Supply or return air grilles for lay in floor mounting with fixed horizontal profiled blades, blades with either 0° or 15° deflection. Type AF-0 and AF-15 respectively. The grille core is removable. The grille can be fitted into masonry. Standard finish: Powder coated RAL 9006 25% gloss.

Sizes Available Minimum Size 150 x 100. Maximum Size 1800 x 600. Standard increments 50mm. For full details see publication 1/1.1/B/...

Order Code AH - 15 - AG Type AF AH WAP AHR (20mm border) WAPR (20mm border) Blade deflection 15° 0°

/

1000 x 150

/

B30

/

S11

/

P3

/

RAL 9010

/

20% Gloss

L x H (mm) Powder coat finish Rear Assemblies A = Grille Face only AG = Rear opposed blade damper D = Rear adjustable blades DG = Rear adjustable blades and damper

Subframe 0 = No subframe B30 = 75mm subframe bracket (30mm borders) for finite grille B20 = as above but for 20mm border grille L30 = 1800mm subframe (30mm borders) for linear grille** L20 = as above but for 20mm border grille

Fixing 0 = Without (screwfix) S11 = With (secret fix) X = Without flange drilling

Note: ** = Also for use when S11 fix plenum box supplied

...-AG Opposed blade action volume control damper, adjustable from the front face.

Type AH - WAP

Type AF H+30/L+30 12.5

75 107

12

...-DG Volume control dampers as ...-AG plus a set of individually adjustable vertical air pattern control blades.

H + 41(21)/L + 41(21)

...-D A set of individually adjustable vertical air pattern control blades.

H/L

32 64

12.5

75 107

Rear Assembly

AH-0 WAP-0

AH-15 WAP-15

H/L

AF-0


Linear grille (with aspect ratio >12 to 1) with ceiling effect (grille installed within 300mm of ceiling). Throw is the distance from sidewall grille to an average velocity of 0.35 m/s.

Air Volume (l/s.m)

Effective Jet Velocity (m/s)

400

300

250

200

175 150 125

L Throw (m)

20 15 10 5

100

2

70

1

80

60

7 6 5 4 3 2

Pressure drop (total) (Pa) 60 40 30

75

AH/AF

75

WAP

100

WAP

150

AH/AF

150 200

WAP AH/AF

200 250

WAP AH/AF

250

WAP

100

20 15 10 7

1.5

Pivot line

50

300

40 30

Type

300

AH/AF

Linear Grilles

350

Nominal height (mm) H

SECTION 4

Performance Data

AH/AF

WAP

By limiting effective jet velocity to 6 m/s all grille sizes shown up to 3m long meet NC35 assuming 8 dB room attenuation and fully open damper.

Subframe

Secret Fixing Detail 32

Concealed fastener factory fitted to grille border

L+6/H+6

‘X’

Type B30 - 30mm border : X = 15 Type B20 - 20mm border : X = 5

15

75

Subframe fixed to surround (No 8 screw by others)

Screwdriver operation to locate fastener tongue behind subframe

13


SECTION 5

Transfer Grille Type AGS Non vision grille for supply or return air with fixed inverted vee blades with visible screw fixing (border counter-punched). The nonvision grille is also available with a matching rear frame - Type AGST

Transfer Grille Type LCG / LVV40 Pressed steel grilles and integral intumescent fireblock (1 hour rated), for use in fire rated doors and partitions.

Transfer Grilles

Size Available Minimum Size 150 x 100. Maximum Size 1200 x 600. Standard increments 50mm. For full details see publication 1/1.1/B/...

Order Code AGS - T

/

Type AGS AGS-T (Matching frame - T)

250 x 250

/

0

/

0

/

P3

/

RAL 9010

/

20% Gloss

/

20% Gloss

Powder coat finish

L x H (mm)

0 = Screwfix X = Without flange drilling

0 = without subframe

Order Code - Fire Block LVV 40

/

Type LVV 40

150 x 150

L x H (mm)

Note: For use with LCG Grilles

Order Code - Pressed Steel Grille LCG Type LCG

14

/

150 x 150 L x H (mm)

/

0

/

0

/

P3

/

RAL 9010 Powder coat finish


AGS

150 x 150 200 x 150 200 x 200 300 x 200 300 x 300 400 x 300 450 x 300 450 x 450 600 x 400 500 x 500 600 x 600 800 x 600 1000 x 600 1200 x 600

3 1 7 9 15 24 38 52 59 90 110 116 171 229 288 347

7 1.5 10 14 23 35 57 78 88 135 164 174 256 344 432 520

12.5 2 14 19 30 47 76 104 117 181 219 232 341 459 576 694

19.5 2.5 17 24 38 59 96 130 147 226 274 290 426 573 720 867

28 3 20 28 45 71 115 156 176 271 329 348 512 688 864 1041

38 3.5 24 33 53 82 134 182 205 316 384 406 597 803 1008 1214

By limiting effective jet velocity to 3 m/s all grille sizes shown meet NC35 assuming 8 dB room attenuation.

Transfer Grilles

Pressure Drop (Pa) Jet Velocity Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s)

Neck Size

SECTION 5

Performance Data

LCG / LVV40 Neck Size 150 x 150 200 x 150 200 x 200 300 x 200 300 x 300 400 x 300 450 x 300 450 x 450 600 x 400 500 x 500 600 x 600

NC20 Volume l/s 45 55 74 100 140 175 200 285 310 325 435

T∆Pa 15 15 15 12 11 10 10 9 9 8 8

NC25 Volume (l/s) 55 70 86 120 170 210 235 325 380 390 530

T∆Pa 23 21 19 18 16 15 14 13 12 12 11

NC30 Volume (l/s) 65 80 105 145 200 250 285 380 450 485 640

T∆Pa 30 30 27 24 20 20 20 17 16 16 15

NC35 Volume (l/s) 80 100 120 170 240 300 340 470 550 560 750

T∆Pa 45 40 35 32 29 26 25 24 22 21 20

Data is for composite unit of 2No. grilles and integral fireblock. NC levels based on 8dB room attenuation.

Type AGS-T

Type LCG/LVV40

Intumescent mastic by others

LVV40 intumescent fireblock

H/L H1+10/L1+10

H/L H1/L1

Type AGS

min25 max44

LCG cover grille

15


SECTION 6

High Capacity Linear Slot Diffuser Type VSD50 The Type VSD50 slot diffuser is available with 1-4 slots. They are characterised by high induction, which results in a rapid decay of supply air velocity and temperature differential. The direction of air discharge can be adapted on site (by others) to the required room conditions.

Size Available

Slot Diffusers

1 to 4 slot lengths available in increments of 150mm.

For full details see publication 2/2.7/B...

Order Code - Diffuser VSD50 - BF - 2 - Z0 - A02

/

1200

/

0

Type VSD50 Style with Black Blades BF (finite) BL (linear) BN (non active) BE (mitre) Style with White Blades WF (finite) WL (linear) WN (non active) WE (mitre)

Length (mm) or mitre angle (deg째) Slots 1-4

A02 = End Angle P02 = End Plate

/

0

/

P3

/

/

RAL 9010

20%

Powder coat finish Fixings SB - support brackets CF - clip fixings BF - bridge fixings BX - bridge fixings for extended height plenum 0 - without

Flange Z0 integral

Order Code - Plenum Box AKV - VSD50 - 4 - BF - D - M Variable Plenum

/

1200 x 248 x 2 x 430

Length (mm)

/

0 1)

Diffuser Type Slots 1-4

Spigot Dia (mm)

Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum

M = Spigot Damper or no entry

1)

Minimum overall height including diffuser with CF fixing = spigot diameter + 81 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 107 mm + Y

Note: For details of Plenum Boxes see page 24.

16

D = Lining or no entry

Number of spigots 1-4

/

0

Overall Height (mm) (including diffuser plus any neck extension Y)


SECTION 6

Performance Data VSD50 Number of Slots

3.0 m 20 - 55 22 40 - 80 14 60 - 100 10 80 - 115 8

Air Volume (l/s/m) min - max Press Drop (Pa) max Air Volume (l/s/m) min - max Press Drop (Pa) max Air Volume (l/s/m) min - max Press Drop (Pa) max Air Volume (l/s/m) min - max Press Drop (Pa) max

1 2 3 4

Throw (m) 4.5 m 20 - 70 36 40 - 100 22 60 - 120 15 80 - 140 13

6.0 m 20 - 80 47 40 - 115 29 60 - 145 20 80 - 165 18

Slot Diffusers

Perimeter throw pattern for VSD diffusers to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Blade configuration as detailed below to be set up on site, by others. Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 25 per hour using special perimeter blade configuration as detailed below. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.

Perimeter Throw Pattern Example shown: 4 slot diffuser

200 to 1000mm

Façade

Throw (m)

300

150

Façade

2.7m

Partition Wall

VSD50 = 59mm

Linear Slot Diffuser - Type VSD50

ALIGNMENT PIN

ALIGNMENT PIN SLOT

Number of Slots

DIM ‘P’ mm

INTEGRAL ‘Z0’ FLANGE

End Angle Dim ‘P’ (mm)

1

77.5

2

123.5

3

169

4

215

End Plate

1.5

11

59

Dimensions

59

DIM ‘P’ mm

1.5

17


SECTION 6

Linear Slot Diffuser Type VSD35 The type VSD35 slot diffuser is available with 1-6 slots. They are characterised by high induction, which results in a rapid decay of supply air velocity and temperature differential. The direction of air discharge can be adapted on site (by others) to the required room conditions.

Size Available

Slot Diffusers

1 to 6 slots lengths available in increments of 150mm.

For full details see publication 2/2.6/B/...

Order Code - Diffuser VSD35 - BF - 2 - Z0 - A02 Type VSD35

/

1200

/

0

Slots 1-6

0

/

P3

/

RAL 9010

/

20%

Powder coat finish Fixings SB - support brackets CF - clip fixings BF - bridge fixings BX - bridge fixings for extended height plenum 0 - without

Length (mm) or mitre angle (deg째)

Style with Black Blades BF (finite) BL (linear) BN (non active) BE (mitre)

/

A02 = End Angle PO2 = End Plate

Flange Z0 integral

Style with White Blades WF (finite) WL (linear) WN (non active) WE (mitre)

Order Code - Plenum AKV - VSD35 - 4 - CF - D - M

1200 x 198 x 2 x 346

Length (mm)

Variable Plenum Diffuser Type Slots 1-6

/

0 1)

Spigot Dia (mm)

1)

M = Spigot Damper or no entry D = Lining or no entry

Minimum overall height including diffuser with CF fixing = spigot diameter + 73 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 99 mm + Y

Note: For details of Plenum Boxes see page 24.

/

0

Overall Height (mm) (including diffuser plus any neck extension Y)

Number of spigots 1-4

Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum

18

/


SECTION 6

Performance Data VSD35 Number of Slots

3.0 m 15 - 40 31 30 - 60 15 45 - 70 10 60 - 80 9

Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max

1 2 3 4

Throw (m) 4.5 m 15 - 50 44 30 - 70 23 45 - 85 16 60 - 100 14

6.0 m 15 - 50 44 30 - 75 26 45 - 95 20 60 - 110 17

Slot Diffusers

Perimeter throw pattern for VSD diffusers to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Blade configuration as detailed to be set up on site, by others. Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 25 per hour using special perimeter blade configuration as detailed. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.

Perimeter Throw Pattern Example shown: 4 slot diffuser

200 to 1000mm

Façade

Throw (m)

300

150

Façade

2.7m

Partition Wall

VSD35 = 51.2mm

Linear Slot Diffuser - Type VSD35

ALIGNMENT PIN

ALIGNMENT PIN SLOT

DIM ‘P’ mm

INTEGRAL ‘Z0’ FLANGE

End Angle

Number of Slots

Dim ‘P’ (mm)

1

62

2

93

3

123

4

154

5

185

6

215

End Plate

1.5

11

59

Dimensions

59

DIM ‘P’ mm

1.5

19


SECTION 6

High Capacity Linear Slot Diffuser Type ALS25 Supply slot diffuser with integral baffle plate and air deflection blades. In the supply mode the discharge can either be set to horizontal or vertical direction by adjustment of the air deflection blades. Available as extract diffuser and also blanked dummy variant.

Slot Diffusers

For full details see publication 2/2.2/B/...

Order Code - Diffuser ALS25 - T2 - 3 - A2

/

/

1200

SB

/

0

/

/

P3

Not Used

Type ALS25

/

RAL 9010

20% Gloss

Powder coat finish

Fixings SB = Support Brackets CF = Clip Fixings BF = Bridge Fixings BX = Bridge Fixings for extended height plenum 0 = Without

Style S = Return (without blades) NA = Non-Active (without blades) E = Mitred corner (non-active without blades 300mm inside legs) T2 = (2 supply blades with spreader plate)

Length of diffuser in mm or Angle of mitre in degrees End Caps / End Plates A1 = One end cap fitted A2 = End cap both ends fitted P1 = One end plate fitted P2 = End plate both ends fitted 0 = None

Number of slots 1 to 4

Order Code - Plenum AKV - ALS25 - 3 - BF - D - M Plenum

/

1200 x 248 x 2 x 370 Length (mm)

Diffuser Type ALS25 Number of Slots 1-4 Fix Type CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum 1)

20

0 1)

Spigot (mm) M = Spigot Damper or no entry D = Lining or no entry

Minimum overall height including diffuser with CF fixing = spigot diameter + 98 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 122 mm + Y

Note: For details of Plenum Boxes see page 24.

/

Number of spigots 1-4

/

0

Overall Height (mm) (including diffuser plus any neck extension Y)


ALS25 Number of Slots Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max

1 2 3 4

Throw (m) 4.5 m 20 - 70 36 40 - 100 22 60 - 120 15 80 - 140 13

3.0 m 20 - 55 22 40 - 80 14 60 - 100 10 80 - 115 8

6.0 m 20 - 80 47 40 - 115 29 60 - 145 20 80 - 165 18

Diffuser recommended active length between 75% and 80% of facade length. Maximum air change rates up to 20 per hour for 1-way discharge pattern, 23 per hour for 2-way discharge pattern. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.

ALS25-T2-1

Slot Diffusers

Air volume shown is based on diffuser used in a 1-way blow configuration to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s.

SECTION 6

Performance Data

ALS25-T2-2 AIR BAFFLE PLATE IN EACH SLOT

DIM ‘A’ mm

DIM ‘A’ mm

76

AIR DEFLECTION BLADES ADJUSTABLE FROM FACE

28

25 SLOT

DIM ‘P’ mm

End Angle

28 28

End Plate

28

75

75

1.5

1.5

25 19.5 25 SLOT SLOT DIM ‘P’ mm

28

Dimensions Number of Slots

Neck A

Face P

1 2 3 4

46.0 90.5 135.0 179.5

81.0 125.5 170.0 214.5

21


SECTION 6

Type ALS20 Supply slot diffuser with integral air straightener, hit and miss damper and air deflection blades. In the supply mode the discharge can either be set to horizontal or vertical direction by adjustment of the air deflection blades. Available as extract diffuser and also blanked dummy variant.

Slot Diffusers

For full details see publication 2/2.1/B/...

Order Code - Diffuser ALS20 - T2 - 3 - A2

/

1200

/

SB

/

0

/

P3

/

Not Used

Type ALS20

RAL 9010

/

20% Gloss

Powder coat finish

Fixings SB = Support Brackets CF = Clip Fixings BF = Bridge Fixings BX = Bridge Fixings for extended height plenum 0 = Without

Style S = Return (without blades) NA = Non-Active (without blades) E = Mitred corner (non-active without blades 300mm inside legs) T2 = (2 supply blades with spreader plate)

Length of diffuser in mm or Angle of mitre in degrees End Caps / End Plates A1 = One end cap fitted A2 = End cap both ends fitted P1 = One end plate fitted P2 = End plate both ends fitted 0 = None

Number of slots 1 to 6

Order Code - Plenum AKV - ALS20 - 3 - BF - D - M Variable Plenum

/

1200 x 248 x 2 x 430

Spigot (mm) Number of spigots 1-4

Number of Slots 1-6 Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum 1)

22

M = Spigot Damper or no entry D = Lining or no entry

Minimum overall height including diffuser with CF fixing = spigot diameter + 98 mm + Y Minimum overall height including diffuser with BF fixing = spigot diameter + 122 mm + Y

Note: For details of Plenum Boxes see page 24.

0 1)

Length (mm)

Diffuser Type ALS20

/

/

0

Overall Height (mm) (including diffuser plus any neck extension Y)


ALS20 Number of Slots

2 3 4 5 6

6.0 m 15 - 55 55 30 - 85 33 45 - 105 22 50 - 120 16 70 - 135 13 75 - 150 11

Air volume shown is based on diffuser used in a 1-way blow configuration to a maximum terminal velocity of 0.75 m/s with average room velocities of 0.25 m/s. Diffuser recommended active length between 75% and 80% of facade length.

Slot Diffusers

Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max Air vol. (l/s/m) min - max Press drop (Pa) max

1

Throw (m) 4.5 m 15 - 55 55 30 - 80 29 45 - 95 18 50 - 110 14 70 - 125 11 75 - 135 9

3.0 m 15 - 45 39 30 - 65 19 45 - 80 13 50 - 90 9 70 - 100 7 75 - 110 6

SECTION 6

Performance Data

Maximum air change rates up to 20 per hour for 1-way discharge pattern, 23 per hour for 2-way discharge pattern. Max NC35 assuming 8dB room attenuation, 1200mm long plenum, recommended max spigot velocity 3.5 m/s.

ALS20-DS-1

ALS20-DS-2

DIM ‘A’ mm

AIR BAFFLE/HIT & MISS SECTION IN EACH SLOT DIM ‘A’ mm

76

ADJUSTABLE FROM FACE AIR DEFLECTION BLADES

28

20 SLOT

DIM ‘P’ mm

End Angle

28 28

End Plate

28

75

75

1.5

1.5

20 19.5 20 SLOT SLOT DIM ‘P’ mm

28

Dimensions Number of Slots

Neck A

Face P

1 2 3 4 5 6

41.0 80.5 120.0 159.5 199.0 238.5

76.0 115.5 155.0 194.5 234.0 273.5

23


SECTION 6

Slot Diffuser Plenum Type AKV All plenums are supplied loose for site assembly to diffuser, Type CF clipped to diffuser prior to installation, Types BF & BX plenum pre-installed for 2nd fix diffuser. Plenum from pre-galvanised, mild steel natural finish. Damper Type M from pre-galvanised perforated sheet. Assembly supported by others (4 no holes provided at top edge of plenum).

Slot Diffusers

Plenum internally lined with 15mm black faced Class O foam if required.

Order Code /

AKV - ALS20 - 3 - BF - D - M

Length (mm)

Variable Plenum

Fixing CF = Clip fix BF = Bridge fix BX = Bridge fix for extended height plenum

D = Lining or no entry

Plenum Lengths & Spigot Positions

24

0

Number of spigots

M = Spigot Damper or no entry

= 2100 = D+100

/

Overall Height (mm)

Number of slots

‘L’

0

Spigot (mm)

Diffuser Type ALS20 ALS25 VSD35 VSD50

‘L’ Max ‘L’ Min

/

1200 x 248 x 2 x 430

L/4

‘L’ Max ‘L’ Min

Spigot Lengths L/2

L/4

= 2100 = 2D+100

Spigot Length Dimension X Spigot Damper

Order Suffix Up to 178Ø

198 to 398Ø

YES

-M-

75mm

100mm

NO

-

40mm

40mm


SECTION 6

Dimensions Type

W

Bc

Bb

Ec

Eb

D Max

1 2 3 4 5 6 1 2 3 4

138 176 214 254 310 380 138 214 254 310

43 82.5 122 161.5 201 240.5 48 92.5 137 181.5

61 100.5 140 179.5 219 258.5 66 110.5 155 199.5

(D+98) (D+98) (D+98) (D+98) (D+98) (D+98) (D+98) (D+98) (D+98) (D+98)

(D+122) (D+122) (D+122) (D+122) (D+122) (D+122) (D+122) (D+122) (D+122) (D+122)

198 248 298 353 448 498 198 298 353 448

Number of slots

W

Bc

Bb

Ec

Eb

D Max

1 2 3 4 5 6 1 2 3 4

138 176 214 254 254 310 138 176 238 310

26.5 57 87.5 118 148.5 179 41.5 87 132.5 178

41 71.5 102 132.5 163 193.5 56 101.5 147 192.5

(D+73) (D+73) (D+73) (D+73) (D+73) (D+73) (D+81) (D+81) (D+81) (D+81)

(D+99) (D+99) (D+99) (D+99) (D+99) (D+99) (D+107) (D+107) (D+107) (D+107)

198 248 298 353 353 448 198 248 348 448

AKV-ALS20

AKV-ALS25

Type

AKV-VSD35

AKV-VSD50

Slot Diffusers

Number of slots

Slot Diffuser Plenum Details

(D+22)

‘Bb’

‘X’

Ø ‘D’

(D+22)

‘Ec’ O/A HEIGHT

‘W’

‘Ec+Y) OR (Eb+Y) O/A HEIGHT

TYPICAL SLOT (VSD TYPE SHOWN)

‘Bc’

‘X’

Ø ‘D’

‘Eb’ O/A HEIGHT

‘W’

(D+22)

‘Bb’

‘X’

Ø ‘D’

‘W’

Type BX or CF

Type CF

Type BF

EXTENSION (*) ‘Y’

Extended Neck Plenum (Type ‘BX’ shown) Extension ‘Y’ Maximum = 1150mm ‘CF’ Types 1100mm ‘BX’ Types Minimum = 25mm All Types

25


SECTION 7

Linear Diffuser Type ADM Opposed blade damper can be provided and where diffuser length exceeds 1200mm, this should be mounted in the plenum box. Plenum box requirements should be forwarded to Trox for assessment/design proposals.

Size Available Heights 150 to 450 in increments of 50mm. Length 300mm minimum

Order Code /

ADM1 - A

1000 x 200

/

/

0

/

0

/

P3

L x H (mm)

Type ADM1 ADM2

Fixing Variant 0 = without (screwfix) S11 = with (secret fix) N2 = with crossbar fixing SB = with support bracket (mitred corner only)

Note 1) Where supplied with plenum AG will be mounted in the plenum only.

Screw Fixing

Secret Fixing Detail

Type O Standard Supply

Type N2 Optional Extra, Cross Bar fixing

Type S11 Optional Extra subframe with concealed fasteners.

Opening size H x L

Included in supply Duct

35

Type ADM1-A

Type ADM2-A Opening size ‘H’ x ‘L’ Type-0 fix

70 30

26

125

Blade Pitch

H-22 / L-22

overall size H + 38 / L + 38

30

7

50

50

7

70

2A

Opening size ‘H’ x ‘L’ Type-0 fix A section AG section

M-1A

Opening size H+6L+6

70 Type / A 140 Type / AG

Border drilled for fixing to duct

20% Gloss

Powder coat finish

Subframe 0 = without A00 = subframe

Style A = Face only AG = Opposed blade damper1)

/

RAL 9010

A section AG section

Fixed Blade Linear Diffusers

For full details see publication 2/2.4/B/...

30

125

Blade Pitch

H-22 / L-22

overall size H + 38 / L + 38

30


Supply Aerodynamic Data ADM-1 H in mm 150 200 250

350 400 450

<10 120 5.0 180 6.1 240 7.1 300 7.9 360 8.7 420 9.4 480 10.0

<10 60 2.0 100 2.6 140 3.1 180 3.5 220 3.9 260 4.2 300 4.6

<10 90 3.0 150 3.9 210 4.7 270 5.3 330 5.9 390 6.4 450 6.9

Pressure Drop (Pa) 12 20 160 200 6.7 8.4 240 300 8.2 10.2 320 400 9.5 11.8 400 10.6 480 11.6

28 240 10.0 360 12.3

38 280 11.7

28 180 6.1 300 7.9 420 9.4 540 10.6 660 11.8

38 210 7.2 350 9.2 490 11.0

Supply Aerodynamic Data ADM-2 H in mm 150 200 250 300 350 400 450

Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m)

Pressure Drop (Pa) 12 20 120 150 4.1 5.1 200 250 5.3 6.6 280 350 6.2 7.8 360 450 7.1 8.9 440 550 7.8 9.8 520 650 8.5 10.7 600 750 9.2 11.5

Fixed Blade Linear Diffusers

300

Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m) Volume (l/s/m) Throw (m)

<10 80 3.3 120 4.1 160 4.7 200 5.3 240 5.8 280 6.2 320 6.7

SECTION 7

Performance Data

The above selections meet noise levels up to and including NC35 assuming 8dB room attenuation. ADM linear diffuser with ceiling effect (horizontal throw). Throw is the distance from diffuser to a velocity of 0.5 m/s.

27


SECTION 8

Type ADT Square louvred face, removable core, ceiling diffusers type ADT giving horizontal air discharge, are suitable for use in rooms with ceiling heights between 2.60 and 4.00m. The recommended supply air temperature differential is Âą10K. The ADT diffuser can be used for supply or extract air applications.

ADT Plenum Box

Louvre Faced Diffusers

Manufactured from pre-galvanised mild steel. Supplied loose for site fixing with either side or top entry spigots, with or without spigot dampers. Plenums are also available internally lined if required and must be supported by the four holes provided on the top edge. For full details see publication PI/2/10.3/B/...

Order Code - Diffuser ADTF - 4 - AG Type

/

ADTF ADTB ADTA ADTT ADTM** ADTS** ADTH***

225 x 225

/

P3

RAL 9010

/

/

State colour

150 x 150 225 x 225 300 x 300 375 x 375 450 x 450 525 x 525 600 x 600*

P3 P4 P6

4 3 2 2C 1

Gloss level

Powder coated white RAL9010 20% gloss (standard) Powder coated black RAL9005 20% gloss Powder coated colour RAL...

Size Discharge directions

20%

Blanking Plate BP-ADT / 450 Diffuser size

Rear Ancillaries A Diffuser face only AG Opposed blade damper fitted to rear of diffuser

Note: *ADTF only **only sizes 150 and 450 ***only size 375

Order Code - Plenum Box AKV - ADT - ZH - D - M

/

450 x 248 x 300 x 380

Diffuser Size (mm)

Variable Plenum

Spigot Dia (mm)

/

0

/

E

/

P4

State colour

ADT

Horizontal spigot (supply) Horizontal spigot (extract) Vertical spigot (supply) Vertical spigot (extract)

No damper Spigot damper 2) Spigot damper cord operated 2) Opposed blade damper fitted to rear of diffuser AGP Opposed blade damper fitted to body of plenum

0 No lining D Lining 1)

2)

28

/ 20% Gloss level

P4 Painted black RAL9005 20% gloss P3 Painted white RAL9010 20% gloss P6 Painted colour RAL...

0 M MC AGF ZH AH ZV AV

RAL9005

Overall Height (mm) (including diffuser)1)

Plenum size (mm) Diffuser Type

/

For ZH, AH minimum height spigot diameter + 102 mm Minimum height with AGF/AGP damper, spigot diameter + 154 mm Minimum height with reduced size plenum + 30 mm on either of above For ZV, AV height fixed at 242mm or 272mm for full or reduced plenum respectively Not available for vertical spigots

0 C E I

Unpainted Painted inside and out Painted outside Painted inside


4-Way Discharge Nominal

vk – m/s

1.0

1.5

2.0

6

13

24

2.5

V˙ in l/s

L in m

LpNC

V˙ in l/s

L in m

LpNC

V˙ in l/s

L in m

LpNC

V˙ in l/s

L in m

LpNC

150x150

4-way

25

0.8

<

36

1.0

<

50

1.5

22

60

2.1

27

225x225

4-way

55

1.2

<

80

1.5

<

105

2.1

19

130

2.7

26

300x300

4-way

95

1.5

<

140

2.2

<

190

3.1

22

240

3.7

28

375x375

4-way

150

1.8

<

225

2.7

<

300

3.7

24

375

4.3

30

450x450

4-way

210

2.1

<

320

3.4

<

425

4.3

25

530

4.6

32

525x525

4-way

290

2.7

<

430

4.0

18

575

4.6

27

720

5.2

32

600x600

4-way

375

3.1

<

560

4.3

19

750

4.9

28

940

5.5

34

37

< indicates values less than 15

Nomenclature:

Note:

V˙ in l/s L in m

The throw distance L should be between 75% and 100% of the distance to the nearest wall or 50% of the diffuser spacing dimension, based on a ceiling height of 2.7 - 2.9m.

vk in m/s Δpt in Pa LpNC

Volume flow per diffuser Distance from the outlet where the maximum time average air velocity is 0.5 m/s Diffuser neck velocity Total pressure drop NC rating of room sound pressure level based on an assumed 8dB room attenuation.

Diffuser with plenum box

Louvre Faced Diffusers

Δpt in Pa

LxH

SECTION 8

Diffuser Only Type ADTF performance data (without damper, if fitted, 100% open)

Type AKV (side entry spigot) Performance is based on sizes and spigot sizes shown in table below. Nominal L x H Spigot ØD Height E min

150 123 277

225 198 352

300 248 402

375 313 467

450 313 467

525 313 467

600 313/398 467/552

Noise level correction for plenum (damper 100% open) Function Supply Extract

ΔLpNC

Size

ΔLpNC

150x150 +11 +11

225x225 +7 +6

1) with 313 Ø spigot

300x300 +9 +5

375x375 +9 +7

450x450 +10 +9

525x525 +13 +10

600x6001) +16 +12

600x6002) +11 +8

525x525 x3.7 x3.2

600x6001) x5.0 x4.3

600x6002) x3.2 x2.7

2) with 398 Ø spigot

Total pressure drop correction for plenum (damper 100% open) Function Supply Extract

Size F F

150x150 x2.2 x2.2

225x225 x1.6 x1.6

1) with 313 Ø spigot

300x300 x1.6 x1.7

375x375 x1.7 x2.0

450x450 x2.4 x2.6

2) with 398 Ø spigot

General guidance on changing spigot diameter ØD with damper 100% open Spigot velocity m/s

2.5

3

3.5

4.0

Approx LpNC

25

30

35

40

Type AKV (Top entry spigot) The effect on performance is small providing spigot velocities do not exceed 3.5 to 4.0 m/s

29


SECTION 8

Nominal duct size L x H

Type 150

225

300

375

450

525

600

ADTF

ADTA/ADTB

ADTT

ADTH* ADTM/ADTS

• •

Type ADTF

Type ADTT (*ADTH) LxH

7

53

53

LxH

15

Louvre Faced Diffusers

*Overall face 495mm lay on 500 mm square ceiling "T" supports

(L + 145) (H + 145) O/A

(L + 145) (H + 145) O/A

The type ADTF has a shaped flanged border for directly mounting to a closed flush ceiling (to maintain horizontal discharge) To fit over ceiling opening size (L+100) (H+100)

The type ADTT has a flat flanged border to enable the diffuser face to be mounted on the back of an exposed ‘T’ bar or directly to a closed flush ceiling Type *ADTH (size 375 only): 495 O/A to ‘lay-on’ 500 square ceiling ‘T’ supports

Type ADTA - ADTB

Type ADTM - ADTS LxH

15 7

‘Z’

53

53

LxH

Detail X&Y

(L + 150) (H + 150) O/A

Type ADTA to locate in ‘clip-in’ ceiling to match bevelled edge tile with ‘PIP’ height = 27.5mm (ie SAS system 150) or 25mm (ie Burgess type ‘A’) Type ADTB to locate in ‘clip-in’ ceiling to match square edged tile with ‘PIP’ height = 25mm (ie Burgess type ‘B’ or ‘D’)

Detail X ADTA ‘PIP’ heights Standard ‘PIP’ heights: 25mm or 27.5mm NB: Non-standard heights available on request

Location clips on border (2 each on opposite sides)

Detail Y ADTB ‘PIP’ heights Location clips on border (2 each on opposite sides) 25

30

Standard ‘PIP’ height: 25mm NB: Non-standard heights available on request

(L + 133) (H + 133) O/A

The types ADTM and ADTS each have a border designed to lay into an exposed Threadline support bar system Type ADTM to ‘lay-on’ threadline ceiling ‘T’ support bar 15mm wide x 16mm deep (dimension Z) Type ADTS to ‘lay-on’ threadline ceiling ‘T’ support bar 15mm wide x 8mm deep (dimension Z) Standard nom (L x H) sizes 150/450


SECTION 8

Table 2 - Available spigot sizes 3)

Table 1 - Maximum Spigot Sizes LxH Nom.

Side Entry Max ØDmm

Top Entry Max ØDmm

Available for diffusers type

150 225 300 375 450 525 600

148 222 298 353 4482) 4982) 5582)

123 198 278 353 398 498 558

ADT / F / A / B / T / M / S ADT / F / A / B / T ADT / F / A / B / T ADT / F / A / B / T / H ADT / F / A / B / T / M / S ADT / F / A / B / T ADT / F / A / B / T

ØDmm Subiect to limitations as shown in table 1 & as noted 98 123 138 148 158 178

198 222 248 278 298 313

348 398 448 498 558

Spigot Length Dimension ‘X’ Spigot Damper

Plenum

Option

E min

E max

F min

F max

AKV-ADT AKV-ADT

‘0’ &‘M’ AGF/AGP

D+102 D+154

1000 1000

D+132 D+184

1000 1000

Order Suffix Up to 178Ø

198 to 398Ø

YES

-M-

75mm

100mm

NO

-

40mm

40mm

Notes:

Effective plenum size L1 x H1 must be at least one size down on nominal L x H.

(L1-2) (H1-2)

Option type ‘AGF’

ADTF border style shown (refer table 1)

Effective

F O/A height required (refer to table 3)

‘ØD’ (Refer table 2)

E O/A height required (refer to table 3)

Option type ‘M’1)

‘X’ 25

‘X’ 25

(L-2) (H-2)

Reduced plenum sizes

‘ØD’ (Refer table 2)

1) Also available with cord operated damper type MC 2) 398 is maximum ØD for type M or MC dampers 3) For performance guidance information on spigot size selection see page 29

Louvre Faced Diffusers

Table 4 - ADT Side Entry Table 3 - Overall height diffuser + plenum

Option type ‘M’1)

Option type ‘AGP’ fitted to the plenum

(L1-2) (H1-2) I/S Plenum

‘D’

‘D’

272

Option type ‘AGF’

242

40

40

(L-2) (H-2) I/S

Option type ‘AGP’ fitted to the plenum

Notes: 1) For full plenum code details refer to page 28 2) All plenums, and if required transformations, are supplied loose for site assembly by others 3) All full size plenums are supplied with clips for diffuser face fixing

4) Holes (4) provided at top edge of plenum for hanging by others 5) AGF and AGP damper adjustment requires core removal 6) Plenum can be internally lined – code D (lining material 12mm black faced class O) foam

31


SECTION 8

Square Diffuser Type ADLQ Type ADLQ high capacity ceiling diffuser comprises a fixed diffuser face with plenum box supplied loose (to be fitted by others), where specified. Low pressure drop and noise levels due to curved blade construction. Available as a four-way face configuration.

Louvre Faced Diffusers

For full details see publication 2/11/EN/...

Order Code - Diffuser ADLQ - A Type A = Diffuser face AG = With OBD AR = With rear mounting ring

/

250 Size (mm) 250 300 400 500 600 625

/

0

/

/

0

P3

/

/

RAL 9010

20% Gloss

Powder coat finish

Not Used

Subframe 0 = Without installation subframe E1 = Duct cross bar

Order Code - Plenum AK - ADLQ - ZH - D - M

/

400 x 198 x 6

/

Diffuser Size

Plenum

Reduced plenum size or blank if standard diffuser size

ZH = horizontal spigot (supply) AH = horizontal spigot (extract) ZV = vertical spigot (supply) AV = vertical spigot (extract)

Spigot size M1) = Spigot, damper or blank D

32

0

Not Used

Diffuser Type

Note : 1) Only available for horizontal spigot (ZH, AH)

/

0

= Lining or no entry


SECTION 8

Performance Data Supply (4 - Way Discharge) Size 250 300 400

600

15 10 30 45 80 135 210 -

21 15 38 53 100 1.1 160 1.2 275 2.0

25 20 45 1.0 65 1.0 115 1.2 175 1.6 290 2.1

30 30 55 1.2 80 1.2 150 1.9 225 2.0 350 2.75

35 45 62 1.4 95 1.3 170 2.5 275 2.7 450 3.5

Lwnc Pressure Drop (Pa) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s)

15 10 30 50 90 180 300

21 15 38 60 110 200 375

25 20 45 70 125 250 450

30 30 54 90 170 300 500

35 45 60 100 200 375 600

Louvre Faced Diffusers

500

Lwnc Pressure Drop (Pa) Volume (l/s) Throw (m) Volume (l/s) Throw (m) Volume (l/s) Throw (m) Volume (l/s) Throw (m) Volume (l/s) Throw (m)

Extract Size 250 300 400 500 600

ADLQ louvre diffuser with ceiling effect (horizontal throw). Throw is the distance from diffuser to a velocity of 0.5 m/s for a 4-Way discharge. All selections shown meet NC35 assuming 8 dB room attenuation.

Type ADLQ-AK

Dimensions ØD 158 158 198 248 313

H 262 262 307 357 420

K 204 254 354 454 554

Q1 248 298 398 498 598

Q2 198 248 348 448 548

K

50

H

ØD

Size 250 300 400 500 600

Type ADLQ-AR

65

Q2-55

ADLQ-AR

Q1

Type ADLQ-A Q2-58 42

108

Type ADLQ-AG

Q2 Q1

33


SECTION 8

Circular Diffuser Type ADLR Aluminium diffusers Type ADLR and ADLR-Q are recommended for flush installation in ceilings. Circular or square configurations can be used in standard ceiling systems. Plenum boxes are available with top or side entry.

Louvre Faced Diffusers

For full details see publication 2/16/EN/...

No entry for standard construction

Order Code ADLR - Q - ZH - M - L

/

598 x 4

/

0

/

0

/

S1

Type ADLR (Circular diffuser) Q

/

RAL 9016 State colour

= Square diffuser (or blank)

A = Diffuser face C = With flap damper AR = With connecting ring

2) Size of Face section 593 598

Top entry plenum ZV = Supply air AV = Extract air

Size of Diffuser 1 2 3 4 5 6 7 8

0

= Standard surface finish stove enamelled to 3)RAL 9010

S1

= Stove enamelled to RAL...

0

= Without subframe = Duct subframe 1)F0 = Standard subframe 1)D0

Side entry plenum ZH = Supply air AH = Extract air Type ADLR - Q 593 - for installation in visible T-bar 598 - for installation in ceiling grid with rear sub-structure

M

= Damper in plenum box spigot 4)MN = Volume setting by cord and measurement test point

1) Required

L

on constructions without plenum box on variants with square face section Type ADLR - Q 3) GL = Gloss level 50 - 60% 4) Available side entry plenum only

= Spigot with lip seal

2) Only

Accessories RZ Circular flap damper and equalising grid Please order accessory RZ separately stating size required

Type ADLR-Q

Type ADLR-Q ØB

ØD

6

35

H1

H2

ØD

K

34

ØP

ØR1 (ADLR)

ØR1 (ADLR)


SECTION 8

Performance Data

Size

Selection Method Linear Pattern Square Pattern Linear Pattern Square Pattern Linear Pattern Square Pattern Linear Pattern Square Pattern Linear Pattern Square Pattern Linear Pattern Square Pattern Linear Pattern Square Pattern Linear Pattern Square Pattern

1 2 3 4 5 6 7 8

Diffuser Centres (m) 2.4 (m) 3.0 (m) Vol Pa Vol Pa 80 130 60 68 110 70 80 35 100 58 130 30 175 60 95 17 130 30 150 25 200 35 100 10 140 19 180 23 230 37 130 12 160 19 220 15 260 25 150 9 180 13 240 15 290 20 175 8 210 10 250 13 320 22 180 7 220 10

1.8 (m) Vol Pa 55 60 45 35 80 35 55 17 95 17 65 8 110 13 70 5 -

3.6 (m) Vol Pa 155 50 250 55 180 32 280 65 200 25 330 40 220 15 360 37 270 19 400 30 280 17

4.2 (m) Vol Pa 300 85 220 40 360 90 260 50 400 50 290 30 450 50 330 32 500 50 360 28

Louvre Faced Diffusers

1.2 (m) Vol Pa 35 22 32 19 50 15 35 7 60 7 50 5 -

Linear Pattern based on a single row of Diffusers. Square Pattern with Diffusers at equal centres. Ceiling diffuser with ceiling effect (horizontal throw). At diffuser centres shown, maximum terminal velocity is 0.25 m/s at 1.0m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open).

Dimensions ØB 201.5 257.5 313.5 369.5 425.5 481.5 537.5 593.5

ØD 123 158 198 248 248 313 313 313

H1 233 233 233 267 267 298 298 298

H2 220 250 295 345 345 410 410 410

K 266 290 372 476 476 567 590 615

ØP 202 258 314 362 426 482 578 590

Ø R2 192 248 304 360 416 472 528 584

ØR2-55

ØR2-51 60

35

ØR2-55

Ø R1 244 300 356 412 468 542 598 654

Type ADLR-AR/ADRL-Q-AR

Type ADLR-Q

Type ADLR

35

Size 1 2 3 4 5 6 7 8

ØR2 ØR1

ØR2

593 or 598

35


SECTION 9

Perforated Diffuser Type ADLQL Type ADLQL ceiling diffuser comprises a perforated diffuser face with rear plenum box, top or side entry. Spigot dampers are only available with side entry plenums. Blanking plates are available on request for site fitting by others.

Perforated Face Diffusers

For full details see publication 2/15.1/B/...

Order Code /

ADLQL - K - ZH - D - M

Size (mm) 300 400 500 600 295 2) 595 2)

Type K = 27mm cover border P = 11mm flush border Supply ZH = horizontal spigot ZV = vertical spigot

1) 2)

0

/

0

/

P3

Not used

/

RAL 9010

/

20% Gloss

Powder Coat finish

Reduced plenum size or blank if standard diffuser size Spigot size

M = spigot1) damper or blank D = Lining1) or blank

Extract AH = horizontal spigot AV = vertical spigot Note:

/

300 X 158 X 0

Only available for horizontal spigot Only available for flush border & layin “T” bar

Dimensions Size 300 400 500 600 295 595

ØD 158 198 248 313 158 313

DA1 290 390 490 590 -

DA2 300 400 500 600 300 600

Blanking Plates

ates

Blanking plate

36

H1 300 340 390 455 300 455

H2 75 75 75 75 -

H3 83 83 83 83 83 83

K1 274 374 474 574 271 571

K2 269 369 469 569 266 566

Q1 336 436 536 636 -

Q2 298 398 498 598 295 595


Supply (4 - Way Discharge) Size 300 400 500 600

10 45 0.7 80 0.85 110 0.85 170 1.2

15 60 0.8 100 1.1 135 1.1 210 1.4

20 70 1.0 118 1.3 158 1.4 240 1.6

25 78 1.1 130 1.4 175 1.5 260 1.8

30 85 1.2 145 1.5 190 1.6 290 2.0

Pressure Drop Volume (l/s) Volume (l/s) Volume (l/s) Volume (l/s)

10 80 105 135 210

15 105 130 160 260

20 120 150 185 300

25 135 170 210 330

30 150 180 225 360

Extract Size 300 400 500 600 Note:

Pressure drop and acoustic data shown is for top entry spigot. For side entry supply & extract acoustic and pressure drop data refer to leaflet 2/15.1/B/...

Horizontal throw distance from diffuser to a velocity of 0.5 m/s for a 4-Way discharge. All selections shown meet NC35 assuming 8 dB room attenuation.

Type ADLQL-P-H

K

K

1

Q

2

1

H1

H1

ØD

ØD

Type ADLQL-K-H

Perforated Face Diffusers

Pressure Drop Volume (l/s) Throw (m) Volume (l/s) Throw (m/s) Volume (l/s) Throw (m) Volume (l/s) Throw (m/s)

SECTION 9

Performance Data

D

Q

8

A1

DA2

1

Type ADLQL-K-V

K

Type ADLQL-P-V 2

D

Q

A1 1

2

Q

2

ØD

8

H3

H2

ØD

K

DA2

37


SECTION 10

Disc Valve Type LVS · Z-LVS The disc valves consist of a valve ring, central disc and installation subframe. To guarantee a perfect seal, the valve ring is fitted with a peripheral sealing strip. A bayonet fitting is used to mount the unit in the installation subframe.

Disc Valves

The air volume flow is adjusted by rotating the central disc which alters the gap between the disc and the valve ring. The central disc is held in position with a locknut.

For full details see publication 1/4/EN/...

Order Code

LVS

/

160

Size Ø (mm) 100 125 160 200

Supply Z - LVS Extract LVS

Type LVS (Extract Valve)

G1

G1 - Subframe O

- No Subframe

Type Z-LVS (Supply Valve)

50

S

ØC

8

ØD

ØE

ØD

ØE

ØC

50

B

B

Dimensions

38

/

Size

B

C

D

E

100

40

99

132

104

125

46

124

162

129

160

54

159

205

164

200

61

199

245

204

8


Type LVS (Extract Valve) Size

100

125

200

-15 -5 0 +5 -15 -5 0 +5 -15 -5 0 +5 -15 -5 0 +5

Air Volume (l/s) 10 30 12 5 70 14 5 <5 17 <5 <5 <5 5 <5 <5 <5

20 120 50 28 270 50 25 15 70 15 10 5 22 8 <5 <5

30 112 56 100 50 30 157 36 22 12 50 17 11 <5

40 300 100 200 89 52 64 38 20 89 30 20 15

50 139 81 100 61 33 140 47 30 23

60 144 88 48 190 68 40 30

80 85 120 77 50

100 175 120 85

120 - Pressure drop (Pa) 220 150 100

Disc Valves

160

Air gap (mm) S

SECTION 10

Performance Data

Type Z-LVS (Supply Valve) Size 100 125 160 200

Volume (l/s) Throw (m) Volume (l/s) Throw (m) Volume (l/s) Throw (m) Volume (l/s) Throw (m)

10 10 0.7 13 0.9 15 0.9 20 1.5

Pressure drop (Pa) 20 30 50 15 18 23 1.1 1.5 2.0 18 21 28 1.4 1.6 2.0 22 27 35 1.5 1.8 2.5 28 35 45 2.1 2.8 3.8

70 28 2.7 33 2.7 42 3.0 55 4.5

Note: Maximum Noise Level NC38, assuming 8dB room attenuation. Throw to a terminal velocity of 0.2 m/s. Performance based on air gap dimension S = 9mm.

39


SECTION 11

Swirl diffusers offer a high induction air distribution method that enables the highest comfort criteria to be achieved. The following range of diffusers each discharge an air stream horizontally across the ceiling. The entrainment and expansion takes place rapidly, and the velocity decay of the air-stream occurs in direct proportion with the distance from the device. High turbulence occurs immediately within the proximity of the diffuser, which allows high air change rates to be successfully supplied into the room. With careful selection swirl diffusers can handle up to 30 air changes per hour while still satisfying relevant comfort criteria.

Minimum Diffuser Centres A, B or C

2.7m

1.0m

Swirl Diffusers

Swirl Diffuser Selection Methodology

X – VH1

Occupied Zone

The layout and centres of the swirl diffusers must be carefully considered to ensure maximum comfort is achieved. We have provided three alternative arrangements for positioning diffusers, selection methods 1, 2 and 3. Each of the selections will ensure that the maximum terminal velocity in the occupied zone (VH1) will not exceed 0.25m/s, 1.0m below ceiling.

40


Minimum Diffuser at Centres A

Diffuser Rows at Centres ≥ 4.0m

Selection Method 2 - Rows ≥ 3.0m apart

Minimum Diffuser at Centres B

Diffuser Rows at Centres ≥ 3.0m

Swirl Diffusers

When the diffuser rows are at least 4.0m apart, the minimum diffuser centres should be ‘A’.

SECTION 11

Selection Method 1 - Rows ≥ 4.0m apart

When the diffuser rows are at least 3.0m apart, the minimum diffuser centres should be ‘B’.

Selection Method 3 - Rows on Square Grid

Minimum Diffuser at Centres C

Diffuser Rows at Centres C

When the diffuser centres in each direction are equal, the minimum diffuser centres should be ‘C’.

41


SECTION 11

Type SDW Square faced adjustable blade swirl diffuser. Type SDW is available in a range of sizes. The removable face plate is held in the plenum box with a centre screw fixing. The head of the screw is covered with a decorative cap. The plenum box is available with side or top entry spigot and a volume control damper.

Swirl Diffusers

For full details see publication 2/7/EN/...

Order Code - Diffuser SDW - QS - Z

/

Diffuser active size 1)

Type

Q QL QM15 QM15 QS15 QS26 QB Note:

500 - 24 - 600

= = = = = = =

Z = Supply A = Extract F = Face Only 2)

Square flush face Square lay in T bar Square lay in threadline 15 x 16 Square lay in threadline 26 x 16 Square lay in threadline 15 x 8 Square lay in threadline 26 x 8 Burgess Ceiling

/

0

/

Q21

/

P3

Not used

/

RAL 9010

/

20% Gloss

Powder coat finish

Blank or oversized ceiling module size Number of blades

0 = Supply air: black air control blades Extract air: no air blades Q11 = Extract air: black air control blades Q21 = Supply air: white air control blades Extract air: white air control blades

1)

Standard sizes Q - 300 x 8, 400 x 16, 500 x 24, 600 x 24, 600 x 48, 625 x 24, 625 x 54 QS15 - 300 x 8 x 600, 400 x 16 x 600, 500 x 24 x 600, 600 x 24 x 600 QB/QL/QS26 - 300 x 8 x 600, 400 x 16 x 600, 500 x 24 x 600, 600 x 24 x 600, 600 x 48 x 600 QM15/QM26 - 300 x 8 x 600, 300 x 8 x 750, 400 x 16 x 600, 400 x 16 x 750, 500 x 24 x 600, 500 x 24 x 750, 600 x 24 x 600, 600 x 24 x 750, 600 x 48 x 600, 600 x 48 x 750, 625 x 24 x 750, 625 x 54 x 750

2)

Face section without central fixing hole, for use on lay in ceilings QL, QS15, QS26, QM15 & QM26 without rear plenum

Order Code - Plenum AK - SDW - ZH - D - MN

/ Diffuser Active Size

Plenum

1) 2)

42

Number of blades Spigot2) Size (mm)

Diffuser ZH = Horizontal Spigot (Supply) AH = Horizontal Spigot (Extract) ZV = Vertical Spigot (Supply) AV = Vertical Spigot (Extract)

500 x 198 x 24

M = Spigot Damper D = Lining or no entry

MN = Spigot damper and test point connection1) or no entry

Only available on ZH type Refer to product data sheet for spigot sizes available with each plenum size


SECTION 11

Performance Data Size

400 x 16

500 x 24

600 x 48

1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C

1.2 m Vol Pa 100 37 75 20 25 5 140 40 100 20 35 5 150 18 110 10 40 3 190 23 130 11 50 2

1.8 m Vol Pa 95 30 70 18 45 7 120 27 85 14 55 9 145 17 105 9 65 4 170 18 110 8 80 4

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 105 40 120 46 75 20 85 27 65 15 85 27 130 33 140 38 90 18 100 20 75 11 100 20 110 20 180 25 110 10 130 14 85 6 115 11 180 20 195 24 120 9 140 13 90 6 120 9

3.6 m Vol Pa 140 65 100 47 110 43 160 50 120 27 120 27 210 35 152 18 170 23 220 30 180 22 180 22

4.2 m Vol Pa 250 50 180 25 220 38 300 55 200 29 230 33

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open).

Swirl Diffusers

600 x 24

Selection Method

For Selection Methodology see page 40.

Dimensions Q 298 x 298 398 x 398 498 x 498 598 x 598 598 x 598

Spigot Lengths Size 300 x 8 400 x 16 500 x 24 600 x 24 600 x 48

ØD 158 198 198 248 248

‘K’ I/S PLENUM

P 250 295 295 345 345

K 288 370 474 565 588

Spigot Length Dimension ‘X’ Spigot Damper

Order Suffix Up to 178Ø

198 to 398Ø

YES

-M-

75mm

100mm

NO

-

40mm

40mm

‘K’ I/S PLENUM

250

‘P’

ØD

‘X’

See Type below

See Type below

Q

15 25

8

8

15

16

595 face size 584 face size

15

584 face size

Type QL

Type QS15

Type QM15

Face-mounted

To ‘Lay-on’ FLAT tee-bar

To ‘Lay-on’ Tegular tee-bar 15mm wide x 8mm deep

To ‘Lay-on’ Tegular tee-bar 15mm wide x 16mm deep

599

16

Tile levelled via centre screw i.e. no location pip 8

35

Type Q

26

584

26

573

Type QB

Type QS26

Type QM26

To ‘Push-In’ spring tee-bar Suitable for ‘tee’ or ‘omega’ type

To ‘Lay-on’ Tegular tee-bar 26mm wide x 8mm deep

To ‘Lay-on’ Tegular tee-bar 26mm wide x 16mm deep

43


SECTION 11

Type VDW Adjustable swirl diffusers type VDW are supplied in a range of sizes. The face plate is circular to suit the architectural requirements The removable face plate is held in the plenum box with a centre screw fixing. The head of the screw is covered with a decorative cap. The plenum box is available with side or top entry spigot, with volume control damper and / or lip seal on request.

Swirl Diffusers

For full details see publication 2/7/EN/...

Order Code VDW - R - Z - V - M - L

/

/

600 x 24

/

0

/

P1

Not Used

Size (mm)

Type

0

RAL 9010

/

20% Gloss

Powder coat finish

R = Circular L = Spigot with lip seal

Z = Supply A = Extract V = Top entry plenum H = Side entry plenum

1)

M = Volume control damper with adjustable lever MN = Volume control damper with cable and test connection

0 = Supply air: black air control blades Extract air: no air blades Q11 = Extract air: black air control blades Q21 = Supply air: white air control blades Extract air: white air control blades

NOTE: 1) Only for supply air with side entry

Type VDW-R-...-H

Type VDW-...-V ØB ØD

H2 ØR

8

35

Type VDW-R-...-

~32 ØD

40

K

H1

ØR/Q

44

/

ØP

ØR


Size

400 x 16

500 x 24

600 x 24

1, Centres A 2, Centres B 3, Centres C x C 1, Centres A 2, Centres B 3, Centres C x C 1, Centres A 2, Centres B 3, Centres C x C 1, Centres A 2, Centres B 3, Centres C x C

1.2 m Vol Pa 100 37 75 20 25 5 140 40 100 20 35 5 150 18 110 10 40 3 190 23 130 11 50 2

1.8 m Vol Pa 95 30 70 18 45 7 120 27 85 14 55 9 145 17 105 9 65 4 170 18 110 8 80 4

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 105 40 120 46 75 20 85 27 65 15 85 27 130 33 140 38 90 18 100 20 75 11 100 20 160 20 180 25 110 10 130 14 85 6 115 11 180 20 195 24 120 9 140 13 90 6 120 9

3.6 m Vol Pa 140 65 100 47 110 43 160 50 120 27 120 27 210 35 152 18 170 23 220 30 180 22 180 22

4.2 m Vol Pa 250 50 180 25 220 38 300 55 200 29 230 33

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open).

Swirl Diffusers

600 x 48

Selection Method

SECTION 11

Performance Data

For Selection Methodology see page 40. If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral collar > 50mm is fitted.

Dimensions Ă˜R 300 400 500 600 600

Size 300 x 8 400 x 16 500 x 24 600 x 24 600 x 48

B 280 364 462 559 580

D 158 198 198 248 248

H1 200 200 200 200 300

H2 250 295 295 345 345

P 278 362 460 557 578

K 290 372 476 567 590

45


SECTION 11

Type FD Type FD swirl diffusers are available in various sizes. Depending on the architectural requirements, the face plate can be circular or square. The fixed air control blades on the diffuser face are arranged radially. The diffuser face can be attached or removed via a centre fix screw into the plenum box. The screw head is covered with a decorative cap. The plenum box can be supplied with either top or side entry spigots and on request, with spigot lip seals and volume control damper.

Swirl Diffusers

If a circular diffuser face is ordered, the plenum box with side entry spigot has a 35mm extension piece fitted to the plenum.

For full details see publication 2/6/EN/...

Order Code FD - Q - Z - V - M - L

/

400

/

Q = Square R = Circular

0

/

/

P1

Not Used

Size

Type

/

0

RAL 9010

/

20% Gloss

Powder coat finish

L = Spigot with lip seal

Z = Supply A = Extract

M = Volume control damper with single blade = Volume control damper with cable and test connection

1)MN

V = Top entry plenum H = Side entry plenum

NOTE: 1) Only for side entry spigot

Type FD-Q-...-H

Type FD-...-V

Type FD-R-...-H

ØB ØD

K

Q

200 8

8

35

H2

ØD

H2

ØD

40

K

Type FD-R-...-

ØR/Q

Type FD-Q-...-

H

R L

ØP

ØR

fixing screw for diffuser face

46


Size

Selection Method

400

500

600

1.8 m Vol Pa 75 60 54 30 35 13 110 40 78 20 52 9 130 28 92 14 65 7 145 20 100 9 70 5

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 80 63 58 33 60 36 45 20 58 33 118 48 120 50 82 23 90 27 68 15 80 21 135 30 150 40 97 16 105 18 85 12 100 17 150 21 160 26 110 11 120 13 95 8 115 12

3.6 m Vol Pa 70 50 80 63 140 65 100 35 100 35 170 48 120 23 125 25 185 30 135 15 145 20

4.2 m Vol Pa 80 63 120 50 130 55 140 30 155 42 220 45 160 25 175 28

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open).

Swirl Diffusers

1, Centres A 2, Centres B 3, Centres C x C 1, Centres A 2, Centres B 3, Centres C x C 1, Centres A 2, Centres B 3, Centres C x C 1, Centres A 2, Centres B 3, Centres C x C

300

1.2 m Vol Pa 85 65 60 36 125 55 85 25 150 40 105 18 160 26 115 12 -

SECTION 11

Performance Data

For Selection Methodology see page 40. If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral collar > 50mm is fitted.

Max Extract for Noise Size

H = (side entry) Vol Pa

V = (top entry) Vol Pa

300

65

40

65

65

400

110

40

115

70

500

170

45

140

80

600

200

40

180

55

Selections shown meet NC38 assuming 5dB room attenuation. Note: Vol = Volume l/s Pa = Pressure Drop

Dimensions Size 300 400 500 600

ØB 280 364 462 559

ØD 158 198 198 248

ØL 254 336 440 530

Q 298 398 498 598

ØR 300 400 500 600

H2 250 295 295 345

K 290 372 476 567

ØP 278 362 460 557

47


SECTION 11

Type DCS Type DCS-P air diffusers consist of the perforated face plate with a thin acoustic fleece lining on the rear. In type DCS-N, the face plate is made of plain sheet steel with perimeter returned edge with central perforated plate insert. The rear swirl diffuser includes a discharge nozzle ring and radially arranged fixed air control blades and connection collar. If required, can be supplied with top entry spigot piece or side entry plenum box with circular spigot. Plenum box can have internal acoustic insulation if specified.

Swirl Diffusers

For full details see publication 2/4.1/EN/...

Order Code DCS - P - V - AK

/

593 x 315

/

/

0

0

/

/

P1

RAL 9010

/

Type Size (mm) 5931) 5982)

Face Plate P = Perforated N = Non-perforated C = With discharge nozzle ring

K US A AK

V = Visible1) H = Hidden2)

= = = =

Not Used

Powder coat finish

Connecting collar Top entry spigot Plenum box Plenum box with acoustic insulation

NOTE: 1) For exposed Tee bar fitting...-V (overall face 593) 2) For hidden Tee bar fitting...-H (overall face 598)

Type DCS-P-...-K

Type DCS-P-...-A/DCS-P-...-AK K1 K

H1

ØC ØB ØR

ØD

8

H2

ØA

8

H2

593 ( 598)

ØC ØB ØR

Type DCS-P-...-US

593 ( 598)

Size...x 125 and ...x 160 without perforated plate ØD

8 ØC ØB ØR

593 ( 598)

48

H3

40

Type DCS-...-H-US Hanging Bracket

598 600

20% Gloss


SECTION 11

Performance Data Size

Selection Method

200

250

315

400

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 50 65 38 41 39 43 30 24 40 45 62 44 68 45 47 25 51 27 40 17 55 28 76 25 90 35 57 18 63 17 47 9 63 17 110 20 120 22 80 11 85 12 65 6 85 12 125 8 140 12 100 6 100 6

1.8 m Vol Pa 50 65 35 31 23 14 62 44 45 24 32 10 78 26 54 13 35 5 105 18 75 9 45 4 115 7 -

3.6 m Vol Pa 45 50 75 55 56 29 70 50 70 20 75 25 140 30 100 17 110 20 155 11 115 7 130 9

4.2 m Vol Pa 50 65 65 45 80 27 100 45 170 45 110 20 140 30 170 16 130 9 150 10

Swirl Diffusers

1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C

160

1.2 m Vol Pa 35 31 70 50 42 20 95 40 51 11 125 25 70 7 125 8 -

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40.

Dimensions Size ...X 160 ...X 200 ...X 250 ...X 315 ...X 400

ØA 158 198 248 313 398

ØB 235 275 325 410 495

Type DCS-...-V-A / DCS-..-V-AK

ØC 210 250 300 385 470

ØD 123 158 198 248 313

H1 180 215 255 305 361

H2 79 79 76 89 89

H3 159 162 167 184 194

K 215 255 305 370 454

K1 237 277 327 392 476

ØR 250 300 350 450 500

Type DCS-...-V-K

Hanging

bracket

593 600

Hanging bracket

593 600

49


SECTION 11

Type TDF TDF - SilentAIR swirl diffusers are available in various sizes. In accordance with architectural requirement the face plate can be circular or square. The fixed air guiding elements of diffuser face are radially arranged. The diffuser can be fastened to the plenum box by means of a central screw and cover cap. The plenum box can be supplied with a horizontal or vertical air connection, or upon request with a volume control damper and / or a sealing lip.

Swirl Diffusers

For full details see publication 2/6.2/EN/...

Order Code TDF - SA - Q - Z - V - M - L Type Silent Air Q = Square R = Circular Z = Supply A = Extract V = Top entry H = Side entry

/

/

400

/

0

0

/

P1

/

Not Used

Size (mm) 300 400 500 600

RAL 9016

/

20% Gloss

Powder coat finish

L = Spigot with lip seal 1)MN

= Volume control damper with sheathed cable and measuring nipple M = Volume control with operating rod

NOTE: 1) MN only with side entry

Type TDF-SilentAIR-Q-...-V

L

ØQ

ØL

ØR

Type TDF-SilentAIR-R-...-V

Central fixing screw for diffuser face

Type TDF-SilentAIR-R-...-H

L

R

R

Type TDF-SilentAIR-Q-...-H

50


Size

300

400

500

1.2 m Vol Pa 80 45 62 28 25 5 92 20 80 17 135 30 100 17 160 22 115 10 -

1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C

1.8 m Vol Pa 80 45 62 28 37 10 92 20 80 17 45 5 135 30 100 17 60 6 160 22 115 10 -

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 80 45 80 45 62 28 62 28 48 17 62 28 92 20 92 20 80 17 80 17 65 11 80 17 135 30 135 30 100 17 100 17 80 10 95 14 160 22 160 22 115 10 115 10 90 7 115 10

3.6 m Vol Pa 80 45 70 38 80 45 100 28 100 28 110 33 140 33 120 22 125 25 165 24 135 14 145 17

4.2 m Vol Pa 80 45 80 45 80 45 110 33 120 37 135 45 150 38 150 38 165 45 190 30 180 27 190 30

Swirl Diffusers

600

Selection Method

SECTION 11

Performance Data

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40. If the diffuser is installed below a closed ceiling (i.e. freely suspended) a stable discharge can be achieved if a peripheral collar > 50mm is fitted.

Dimensions Size 300 400 500 600 625

ØB 280 364 462 559 559

Type TDF-SilentAIR-...-V

ØD 158 198 198 248 248

ØL 254 336 440 530 530

Q 298 398 498 598 623

ØR 300 400 500 600 623

H2 250 295 295 345 345

Type TDF-SilentAIR-Q-...-H

ØB ØD

K ~32

ØD

~32

Q

8

Q/ØR

8

35

ØD

H2

200

ØP 278 362 460 557 557

Type TDF-SilentAIR-R-...-H

H2

40

K

K 290 372 476 567 567

ØP

ØR

51


SECTION 11

Type TDV The diffuser face of the type SilentAIR offers a high volume flow rate at low sound power levels. The horizontal swirl-type discharge of the supply air ensures high induction and hence rapid reduction in jet velocity and temperature differential. Suitable for supply air temperature differentials up to ±10°K. Depending on requirements, the diffuser can be supplied with a circular or square face and with either white or black air control blades. For the air connection a plenum box is used. The connection can be top or side entry. Face fixing with centre screw and cover cap.

Swirl Diffusers

For full details see publication 2/7.1/EN/...

Order Code TDV - SA - Q - Z - V - M - L

/

400

0

/

/

Q = Square R = Circular

Size (mm) 300 400 500 600

Z = Supply A = Extract

L = Spigot with lip seal

Type Silent Air

V = Top entry H = Side entry

Q21

/

P1

/

RAL 9010

/

20% Gloss

Powder coat finish Not Used

M= Volume control with operating rod Volume control damper with sheathed cable and measuring nipple

1)MN=

Air control blades 0 = Supply air: black Extract air: no Q11 = Extract air: black Q21 = Supply air: white Extract air: white

NOTE: 1) Only with side entry

Type TDV-SilentAIR-Q-...-

ØL

ØQ

ØL

ØR

Type TDV-SilentAIR-R-...-

Central fixing screw for diffuser face

52


Size

300

400

500

1.2 m Vol Pa 80 45 65 30 120 36 85 19 150 38 100 17 170 25 120 12 -

1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C

1.8 m Vol Pa 80 45 65 30 40 13 120 36 85 19 50 6 150 38 100 17 65 8 170 25 120 12 -

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 80 45 80 45 65 30 65 30 50 19 60 25 120 36 120 36 85 19 85 19 65 12 80 16 150 38 150 38 100 17 100 17 80 10 100 17 170 25 170 25 120 12 120 12 100 9 120 12

3.6 m Vol Pa 80 45 70 37 75 40 120 36 100 27 110 30 155 39 125 25 140 30 180 28 140 16 150 18

4.2 m Vol Pa 80 45 80 45 80 45 120 36 120 36 120 36 160 40 150 38 160 40 200 34 190 30 180 28

Swirl Diffusers

600

Selection Method

SECTION 11

Performance Data

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40.

Dimensions Size 300 400 500 600 625

ØB 280 364 462 559 559

ØD 158 198 198 248 248

ØL 254 336 440 530 530

Type TDV-SilentAIR-...-V

Q 298 398 498 598 623

ØR 300 400 500 600 623

H2 250 295 295 345 345

Type TDV-SilentAIR-Q-...-H

ØB ØD

K ~32

ØD

~32

Q

8

Q/ØR

8

35

ØD

H2

200

ØP 278 362 460 557 557

Type TDV-SilentAIR-R-...-H

H2

40

K

K 290 372 476 567 567

ØP

ØR

53


Available in either circular or square face plate, with or without discharge nozzle, to suit architect requirements. Type RFD-...-UO or RFD-...-UD, top entry plenum boxes are inclusive of internal subframe which holds the diffuser in position by central fixing bolt and covering cap.

For full details see publication 2/4/EN/...

Order Code RFD - Q - D - A - M - L

200

/

/

0

/

0

/

P1

RAL 9010

/

Type Size (mm) 125 160 200 250 315 400

Diffuser Face Q = Square R = Circular D = nozzle K = Connecting ring US = Top entry plenum UD1) = Top entry plenum with internal subframe (discharge nozzle construction) UC1) = Top entry plenum with internal subframe (no discharge nozzle) A = plenum box side entry N1) = Low profile plenum box

Powder coat finish

Not Used

L = Plenum box with lip seal M = Volume control damper with operating rod = Volume control damper with sheathed cable and test nipple

2)MN

NOTE:

1) 2)

Type RFD-R-D-K

Only available with circular construction Not available with N

Type RFD-Q-D-US

ØA

U4

U2

40

ØD

ØR2 Q2

Type RFD-R-D-US

8

SECTION 11 Swirl Diffusers

Type RFD

Type RFD-R-D-UD wK

ØD

xC wQ 1 x R1

54

8

H4

U6

H1

H3

xD

40

32

48

ØR2

/

20% Gloss


Size

Selection Method

160

200

250

315

400

1.8 m Vol Pa 35 50 24 20 18 15 47 40 33 19 24 12 63 34 45 15 30 8 80 23 53 11 35 4 105 15 75 8 45 2 118 11 -

Diffuser Centres (m) 2.4 m 3.0 m Vol Pa Vol Pa 35 50 38 60 27 35 29 38 23 19 29 38 47 40 53 50 35 21 37 27 30 16 40 30 63 34 68 38 48 18 50 20 38 9 50 20 80 23 100 36 54 11 55 12 45 7 55 12 105 15 110 17 78 9 80 9 60 5 80 9 120 12 140 16 90 7 105 9 100 8

3.6 m Vol Pa 45 80 32 45 40 70 60 65 40 30 55 55 75 45 55 24 68 38 120 50 68 15 60 13 130 25 90 11 105 15 155 18 120 12 125 13

4.2 m Vol Pa 50 100 38 60 50 100 70 95 47 40 70 95 85 65 65 35 90 70 140 70 78 20 95 32 140 27 100 14 145 29 175 25 135 15 150 17

Swirl Diffusers

1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C 1, Centres A 2, Centres B 3, Centres C

125

1.2 m Vol Pa 40 70 25 28 55 55 32 18 15 9 67 37 43 14 110 40 52 10 115 18 72 8 130 14 -

SECTION 11

Performance Data

Note: Vol = Volume (l/s) Pa = Pressure Drop

Swirl diffuser with ceiling effect (horizontal throw). Minimum diffuser centres ensure maximum terminal velocity is 0.25 m/s at 1.0 m below ceiling. All selections shown meet NC38 assuming 5dB room attenuation including side entry plenum box and spigot damper (fully open). For Selection Methodology see page 40.

Dimensions Size 125 160 200 250 315 400

ØA 123 158 198 248 313 398

ØC 123.5 158.5 198.5 248.5 313.5 398.5

ØD 98 123 158 198 248 313

H1 259 284 314 359 409 474

H3 195 220 250 295 345 410

H4 178 190 202 227 252 285

K 216 266 290 476 567 615

Q1 198 198 248 298 398 498

Q2 198 248 248 298 398 498

Ø R1 158 197 241 295 364 450

Ø R2 200 250 300 350 450 580

U2 75 78 78 75 88 88

U4 153 158 161 166 183 193

U6 192 196 197 202 219 229

55


SECTION 12

Type DUK - Standard Supply

Jet Nozzles

For full details see publication 1/5/EN/...

Jet nozzles type DUK are suitable for almost all situations because of the wide range of variants available. Fixed construction type DUK-F consists of a nozzle with fixing holes. Adjustable construction type DUK-V consists of a spherical discharge nozzle mounted flange and circular spigot for direct connection to a circular duct. The nozzle can be adjusted manually up to max. 30° in any direction. The adjustment can be motorised with an electric or pneumatic actuator. With an actuator the nozzle can only be rotated in one plane up to 30° upwards (cooling) and up to 30° downwards (heating).

Order Code /

DUK - V - K - E1

Size (mm)

Type P1) V

250

/

/

0

/

0

P3

/

RAL 9010

/

20% Gloss

Not Used Powder coat finish

= Fixed = Adjustable

Only with construction V K = Duct connection element A = As K plus spigot R = Duct connection element for circular ducting

Only with construction V P = With pneumatic actuator E1 = external Rotary actuator 220 V, 50 Hz E2 = external Rotary actuator 24 V, 50 Hz E3 = external Rotary actuator 24 V, 50 Hz, 0...VE4 = internal linear actuator 220 V, 50 Hz E5 = internal linear actuator 24 V, 50 Hz E6 = internal linear actuator 24 V, 50 Hz, 0...V+

NOTE: 1) Drilled for fixing as standard: extra text required on order if no holes are required. For sizes 100 and 125, construction with actuator not available

Performance Data Size 100

125

160

200

250

315

400

Volume (l/s) Throw L (m) Rise + Fall (m) Volume (l/s) Throw L (m) Rise + Fall (m) Volume (l/s) Throw L (m) Rise + Fall (m) Volume (l/s) Throw L (m) Rise + Fall (m) Volume (l/s) Throw L (m) Rise + Fall (m) Volume (l/s) Throw L (m) Rise + Fall (m) Volume (l/s) Throw L (m) Rise + Fall (m)

13 3.9 0.6 17 3.9 0.55 23 3.5 0.38 29 3.8 0.6 37 3.8 0.9 50 3.9 1.3 65 3.9 1.7

17 4.5 0.43 25 5 0.5 35 5.1 0.3 55 6.5 1.1 60 5.4 1.5 100 7 1.8 150 9 2.5

22 5.8 0.44 35 7 0.75 50 7.5 1.1 85 10 2 95 8.5 1.6 200 13.8 3 250 13 4

28 6.9 0.5 45 8.5 0.9 70 10.5 1.6 120 13 3.3 140 12.5 2.8 300 21 4.9 350 18.5 4.6

35 9 0.62 55 11 1.3 95 14 1.8 180 21 3.4 190 17.8 3.3 400 28 9 500 25 7

Based on horizontal discharge with air temperature ±10k above or below room temperature to a terminal velocity of 0.75 m/s without ceiling effect. Selections meet NC45 assuming 15dB room attenuation.

56


SECTION 12

Heating rise

Drop and rise is directly proportional to supply air temperature differential.

fall Cooling

Jet Nozzle Throw

d i

i di

l

i

l

Size

D1

D2

D3

D4

D5

E

F

K

L1

L2

L3

Size

100 125 160 200 250 315 400

136 159 225 265 315 400 485

115 138 201 241 291 376 461

146 169 200 257 302 384 467

98 123 158 198 248 313 398

50 64 82 108 136 174 230

10 10 11 16 16 23 24

-2 4 10 14 23 29 47

134 157 188 242 287 358 441

94 112 122 153 187 224 287

78 89 106 127 159 189 223

80 90 110 140 170 220 260

100 125 160 200 250 315 400

200

Possible Circular Duct Diameters R 250 315 500 630 800

• • •

• • • •

• • • • •

• • • • •

Jet Nozzles

D

Dimensions

L

*For constructions with actuators, L3 = 365mm irrespective of size.

Type DUK-V-R-E (1-3 shown)

Type DUK-V-A-E/DUK-V-K-E (1-3 shown)

L 3*

L3*

E

Rotary actuator 15

øD3

60°

øK øD4

øD3

øK

60°

øR

Rotary actuator

DUK-V-R-E1...E3 (shown) DUK-V-R-E1...E3 (shown) DUK-V-R-P DUK-V-R-P

DUK-V-A-E1...E3 (shown) DUK-V-A-E1...E3 (shown) DUK-V-K-E1...E3 (shown) DUK-V-A-P DUK-V-K-E1...E3 (shown) DUK-V-K-P DUK-V-A-P DUK-V-K-P

Type DUK-V-R Examples of circular duct connection

15

Type DUK-V L2 L1

10

ØD1 ØD2

9

DUK V

F Counterpunched hole Ø 4.5mm for raised countersunk self-tapping screws 4.2 x 16, DIN 7973

ØD5

Type DUK-V-K Examples of rectangular duct connection

øD5 øD3

øD4

E

DUK-F

Type DUK-F

57


SECTION 12

Type AJA - Standard Supply Comprises of a Spun Jet Nozzle section mounted in a square face plate with angle flanged border for mounting onto clients duct or plenum. Border supplied undrilled as standard, type CF comes without the square face plate. Jet Nozzle can be adjustable 30ツー upwards to 30ツー downwards. The Nozzle mounting plate can also be rotated through 360ツー which enables the air jets to be fully directional. One, two, three or four elements are available and there are four sizes to choose from. TROX jet nozzle can be installed singularly or in banks.

Jet Nozzles

For full details see publication 1/5.1/B/...

Order Code /

AJA - CF - A

250 X 2

/

/

0

0

/

/

P3

/

RAL 9010

Type Size 200 250 300 350

CF = Circular Face or blank Rear Assemblies A = Without

Not Used

0 = drilled (screwfix) X = undrilled Powder coat finish

Number of elements 1)1 - 4

NOTE: 1) 2, 3 and 4 elements for AJA-A only

Order Code AK - AJA - ZV - AG

/

250 X 2

/

0

/

GO

Plenum Size (mm) 200 250 300 350

Nozzle Type ZV = supply nozzle with inline connection AG = Damper or blank

Not Used Number of elements -4

1) 1

NOTE: 1)Plenum for CP (circular face) only available for single element units

Dimensions

200 250 300 350

C 350 400 450 500

L2 650 750 850 950

Nominal Size L4 テ連 1250 200 1450 250 1650 300 1850 350

L3 950 1100 1250 1400

Heating

E 50 65 75 85

F 180 195 205 235

WxZ 310 310 360 360 410 410 460 460

B 200 250 300 300

H 200 250 300 350

30

Size

C

rise

Jet Nozzle Throw L

Cooling

Drop and rise is directly proportional to supply air temperature differential.

58

30

fall L2

L3

L4

20% Gloss


AJA Size 200 1 Element

250 300 350

Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m)

95 140 190 230 280 8 9 12 15 18 4.0 5.5 7.0 9.0 10.0 12 15 9.0 10.0 11 14 12.0 12.5 11 8.5

AJA

250 300 350

Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) AJA

Size 200 3 Element

250 300 350

Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m)

380 420 470 570 660 750 11 12 14 15 17 20 6.5 7.0 7.5 8.0 8.5 9.0 12 14 25 7.5 9.0 9.5 11 12 14 10.0 10.5 11.0

AJA Size 200 4 Element

250 300 350

Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m) Throw L (m) Rise + Fall (m)

420 470 570 9 11 12 4.5 5.0 5.5

660 14 6.5 11 6.5

750 15 7.0 12 7.0

850 940 1040

18 21 24 28 30 11.5 13.0 14.0 15.5 17.0 17 18 21 24 28 34 37 43 15.0 16.5 18.0 20.0 22.0 24.0 34.0 43.0 14 15 17 20 24 28 30 34 37 14.0 15.5 17.0 19.0 24.0 29.0 31.0 33.0 35.0

Volume (l/s) 850 940 1040 23 24 28 10.0 13.0 15.0 17 18 21 10.0 11.0 12.0 15 17 18 12.5 13.0 14.0 12 14 15 11.0 13.0 15.0 Volume (l/s) 850 940 1040 17 18 21 7.5 9.0 9.5 14 15 17 7.5 8.0 9.0 14 9.5

570 21 11.0 15 10.5 14 12.5 12 19.0

660 24 13.0 18 12.0 15 14.5 14 24.0

750 28 16.0 21 13.0 18 15.5 15 29.0

850 940 1040

24 28 29 14.5 16.0 19.0 21 24 26 18.0 20.0 22.0 18 20 21 31.0 33.0 35.0

Jet Nozzles

2 Element

Volume (l/s) 380 420 470 570 660 750

Volume (l/s) 95 140 190 230 280 330 380 420 470 8 9 11 12 14 15 17 5.0 5.5 6.0 6.5 7.5 8.0 9.0 11 12 14 7.5 8.0 9.0 9 11 12 7.0 10.0 11.0

Size 200

330 21 12.0 17 10.5 15 14.5 12 12.0

SECTION 12

Performance Data

1130 1230 1320 1420 1650 1890

23 24 25 28 12.5 13.0 14.0 14.5 20 21 23 24 28 32 14.5 15.0 16.0 17.5 19.0 22.0 17 18 20 21 24 28 16.0 17.5 19.0 21.0 23.5 26.0

1130 23 10.0 18 10.0 15 10.0 14 13.5

1230 24 11.0 18 10.5 17 12.0 15 14.0

1320 26 11.5 20 10.0 18 13.0 15 14.5

1420 1650 1890

21 24 29 11.5 13 14.5 20 21 26 15.0 17.0 19.0 17 18 21 15.0 17.0 18.0

Based on horizontal discharge with air temperature ±10K above or below room temperature to average terminal velocity of 0.25m/s without ceiling effect. Selections meet NC45 assuming 15dB room attenuation.

Type AJA Standard type with square face section. Border: for plenum or flanged duct fitting. Flange duct section

Installation

Suspension by others

BxH

A Nominal size

Lockable lever

30

C

30

Duct

W x Z duct size

F

60° Conical Adjustment

Ø A nom size

E

450

Side View of Plenum Box Type AJA - PG Shown

59


Design changes reserved. All rights reserved Š TROX UK Ltd (06/2009)

The art of handling air

TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Tel: +44 (0) 1842 754545 Fax: +44 (0) 1842 763051 E-Mail: sales@troxuk.co.uk www.troxuk.co.uk