Project Daylight
Central Lawrenceville, Pittsburgh Project Scope Definition 22 October 2010 Ellen Chou, Anna Hong, Jiwon Hur, Alexandra Legrady, Eric Smith
INDEX INDEX GENERAL USE STIPULATIONS PROJECT NARRATIVE PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS PROJECT SCOPE: SUN/SHADOW DATA PROJECT SCOPE: TOPOGRAPHICAL DATA PROJECT SCOPE: WIND DATA PROJECT SCOPE: ENVIRONMENTAL DATA PROJECT SCOPE: HOUSING LOCATION PROJECT SCOPE: HOUSING LOCATION PROJECT SCOPE: HOUSING LOCATION PROJECT SCOPE: HOUSING LOCATION PROJECT SCOPE: LAND USE AND ZONING REQUIREMENTS PROJECT SCOPE: LAND USE AND ZONING REQUIREMENTS PROJECT SCOPE: SITE UTILIZATION PROJECT SCOPE: SITE UTILIZATION PROJECT SCOPE: SITE UTILIZATION PROJECT SCOPE: SITE UTILIZATION PROJECT SCOPE: LAND USE / SITE UTILIZATION DEVIATION PROJECT SCOPE: LAND USE / SITE UTILIZATION DEVIATION PROJECT SCOPE: HOUSING CONDITION PROJECT SCOPE: HOUSING CONDITION PROJECT SCOPE: HOUSING CONDITION PROJECT SCOPE: HOUSING CONDITION PROJECT SCOPE: MATERIALS AND CONSTRUCTION PROJECT SCOPE: MATERIALS AND CONSTRUCTION PROJECT SCOPE: MATERIALS AND CONSTRUCTION PROJECT SCOPE: HEATING AND COOLING SYSTEMS PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - AXONOMETRIC PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - ELEVATION PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - ELEVATION PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - PLAN PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - PLAN PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - SECTION CODE ANALYSIS CODE ANALYSIS CODE ANALYSIS CODE ANALYSIS CODE ANALYSIS: PROPORTION STUDY SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND SITE CONTEXT: EXISTING ASSETS AND LIABILITIES SITE CONTEXT: SUN STUDIES SITE CONTEXT: GENERAL SITE MODIFICATIONS SITE CONTEXT: GENERAL SITE MODIFICATIONS SITE CONTEXT: GENERAL SITE MODIFICATIONS SITE CONTEXT: GENERAL SITE MODIFICATIONS SITE CONTEXT: GENERAL SITE MODIFICATIONS SELECTIVE DEMOLITION: DIAGRAMS SELECTIVE DEMOLITION: DIAGRAMS ADAPTIVE TRANSFORMATION: INDEX ADAPTIVE TRANSFORMATION: EXTERIOR PERSPECTIVE ADAPTIVE TRANSFORMATION: EXTERIOR PERSPECTIVE ADAPTIVE TRANSFORMATION: FIRST FLOOR PLAN ADAPTIVE TRANSFORMATION: FIRST FLOOR PLAN ADAPTIVE TRANSFORMATION: SECOND FLOOR PLAN ADAPTIVE TRANSFORMATION: SECOND FLOOR PLAN ADAPTIVE TRANSFORMATION: FIRST FLOOR REFLECTED CEILING PLAN ADAPTIVE TRANSFORMATION: FIRST FLOOR REFLECTED CEILING PLAN ADAPTIVE TRANSFORMATION: ENLARGED FIRST FLOOR PLAN ADAPTIVE TRANSFORMATION: ENLARGED FIRST FLOOR PLAN ADAPTIVE TRANSFORMATION: SECTION WEST ADAPTIVE TRANSFORMATION: SECTION WEST
IN1.00
INDEX
IN1.00 IN1.01 IN1.02 PN1.00 PS1.00 PS1.01 PS1.02 PS1.03 PS1.04 PS1.05 PS2.00 PS2.01 PS2.02 PS2.03 PS3.00 PS3.01 PS3.02 PS3.03 PS4.00 PS4.01 PS5.00 PS5.01 PS5.02 PS5.03 PS6.00 PS6.01 PS7.00 PS7.01 PS7.02 PS7.03 PS8.00 PS8.01 PS8.02 PS9.00 PS10.00 PS10.01 PS10.02 PS10.03 PS10.04 PS10.05 PS10.06 CA1.00 CA1.01 CA1.02 CA1.03 SP1.00 SP1.01 SP1.02 SC1.0 SC1.01 SC1.02 SC1.03 SC1.04 SC1.05 SC1.06 SD1.00 SD1.01 AT0.00 AT1.00 AT1.01 AT1.02 AT1.03 AT1.04 AT1.05 AT1.06 AT1.07 AT1.08 AT1.09 AT1.10 AT1.11
Pittsburgh Program for the Adaptive Transformation of Community Housing
ADAPTIVE TRANSFORMATION: ENLARGED SECTION WEST ADAPTIVE TRANSFORMATION: ENLARGED CROSS SECTION ADAPTIVE TRANSFORMATION: SOUTH ELEVATION ADAPTIVE TRANSFORMATION: SOUTH ELEVATION ADAPTIVE TRANSFORMATION: EAST ELEVATION ADAPTIVE TRANSFORMATION: EAST ELEVATION ADAPTIVE TRANSFORMATION: WEST ELEVATION ADAPTIVE TRANSFORMATION: WEST ELEVATION ADAPTIVE TRANSFORMATION: PERSPECTIVE SECTION ADAPTIVE TRANSFORMATION: PERSPECTIVE SECTION ADAPTIVE TRANSFORMATION: AXONOMETRIC SECTION ADAPTIVE TRANSFORMATION: AXONOMETRIC SECTION ADAPTIVE TRANSFORMATION: PLAN DETAIL 1 ADAPTIVE TRANSFORMATION: PLAN DETAIL 2 ADAPTIVE TRANSFORMATION: PLAN DETAIL 3 ADAPTIVE TRANSFORMATION: PLAN DETAIL 4 ADAPTIVE TRANSFORMATION: SECTION DETAIL 1 ADAPTIVE TRANSFORMATION: SECTION DETAIL 2 ADAPTIVE TRANSFORMATION: SECTION DETAIL 3 ADAPTIVE TRANSFORMATION: SECTION DETAIL 4 ADAPTIVE TRANSFORMATION: SECTION DETAIL 5 ADAPTIVE TRANSFORMATION: SECTION DETAIL 6 ADAPTIVE TRANSFORMATION: WINDOW DIAGRAM ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ASSEMBLY SEQUENCE: PICTORIAL DEPICTION OF STAGED IMPLICATION ADAPTIVE TRANSFORMATION ORIENTATION MODIFICATION ADAPTIVE TRANSFORMATION ORIENTATION MODIFICATION IMPLEMENTATION DOCUMENTATION: LOGISTICS IMPLEMENTATION DOCUMENTATION: LOGISTICS IMPLEMENTATION DOCUMENTATION: LOGISTICS IMPLEMENTATION DOCUMENTATION: LOGISTICS IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS IMPLEMENTATION DOCUMENTATION: HARD COST ANALYSIS IMPLEMENTATION DOCUMENTATION: PAYBACK ANALYSIS
ARC48_550
AT1.12 AT1.13 AT1.14 AT1.15 AT1.16 AT1.17 AT1.18 AT1.19 AT2.00 AT2.01 AT2.02 AT2.03 AT3.00 AT3.01 AT3.02 AT3.03 AT3.04 AT3.05 AT3.06 AT3.07 AT3.08 AT3.09 AT3.10 AS1.00 AS1.01 AS1.02 AS1.03 AS1.04 AS1.05 AS1.06 OM1.00 OM1.01 IMP1.00 IMP1.01 IMP1.02 IMP1.03 IMP2.00 IMP2.01 IMP2.02 IMP2.03 IMP2.04 IMP2.05 IMP3.00 IMP3.01
INDEX
IN1.01
GENERAL USE STIPULATIONS: These documents are the copyrighted and intellectual property of Carnegie Mellon University Pittsburgh Program for the Adaptive Transformation of Community Housing and cannot be reproduced in whole or in part without permission. No document may be taken out of the index without consideration for all other drawings in the set. Drawings may not be scaled or modified. No change may be made without consultation of the architect. The architect assumes no responsibility for misinterpretations, omissions, or errors on account of using incomplete or altered sets of documents that have not been approved.
IN1.02
GENERAL USE STIPULATIONS
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
PROJECT DAYLIGHT
Project Daylight is a design modification that can be applied to an existing housing typology in Lawrenceville. This transformation, although shown for a specific home can be adapted to any mason’s row house to improve daylighting in the home and minimize utility costs by taking advantage of passive strategies. The implementation strategies presented are designed to provide an affordable path to the realization of renovation that can impact and revitalize the Lawrenceville area.
LAWRENCEVILLE
The Central Lawrenceville neighborhood is one of Pittsburgh’s most diverse districts. The population reflects multiple income levels, ages, races, and family structures. The built environment itself is equally dynamic with industrial areas directly next to single family houses, row homes, apartment buildings, and commercial streets. As with much of the city, the neighborhood suffered from a rapid exodus of population in the last fifty years. However, the city has recently marked it as a “hip” destination for artists and young professionals, reflected by the revitalization of Butler Street businesses and new influx of people.
HOUSING TYPOLOGY
The common features of this mason’s row type include two story constructions with an attic typically defined by a single center dormer facing the street façade. On the other floors, three bays are defined by equally spaced windows that face the street. Many have been modified over the years. Common modifications found in Lawrenceville include an addition in the rear of one or two stories, and front porches with proper setbacks. Some owners even chose to enclose their porches for more heated indoor space. Historically, heating systems were fueled by coal, and many have a chute in front for coal deliveries.
IMPLEMENTATION
The adaptive transformation of the porch along the front façade will extend the living space and improve the overall daylighting in the house. This glass extension can utilize passive heating strategies in the winter to minimize utilities. In the summer the porch can be completely open, taking advantage of natural ventilation. Collecting rain water and adding plantings will stop flooding and cut back on water usage for irrigation. Ultimately, the approaches defined will improve the quality of life in the Central Lawrenceville neighborhood through sustainable and affordable means.
PROJECT NARRATIVE
PN1.00
POPULATION & RACE (2000, 2008)
KEY Population (2000) White
The current population that resides in Central Lawrenceville (4,654) is the largest of the three when compaired to those of Lower (2,295) and Upper Lawrenceville (2,495). Relatively, it is nearly double that which can be found in either of the other two. Since 2000, Lawrenceville overall has experienced a significant decrease in population, the majority of which occured in Central Lawrenceville. However, when studying this drop relative to the lower and upper regions, Central Lawrence has exhibited the smallest percetage decrease over time.
African American Asian Other
Overall, studies of the racial demographics that make up Lawrenceville reveals a relatively homogeneous population that is predominately White. A smaller African American and Asian population makes up the remaining demo along with an even smaller population comprised of other ethnicities.
LOWER LAWRENCEVILLE
In comparison to the greater Lawrenceville region, Central Lawrenceville has the greatest number of people in all of the age groups except for those in their sixties to mid seventies. Out of the population of Central Lawrenceville, the majority are in their mid thirties to late fifties, with a similar percentage found to be in their early years to mid thirties, implying a family oriented population make up. Another demographic that can be found in Central Lawrenceville is the elderly, who are in their mid seveties and onwards.
KEY Lower Central Upper
5 - 19
AGE GROUP
AGE STRUCTURE OF POPULATION
CENTRAL LAWRENCEVILLE
20 - 34 35 - 59 60 - 74 75 +
PS1.00
PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS
UPPER LAWRENCEVILLE
-13.9%
9
2,899
5
2,495
Pittsburgh Program for the Adaptive Transformation of Community Housing
LOWER
CENTRAL
UPPER
$44,468
$51,042
$46,328
86%
86%
ARC48_550
MEDIAN HOME VALUE PERCENTAGE OF HOMES OCCUPIED
82%
11.9
14.3
15
42.2% owner 57.8% renter
51.8% owner 48.2% renter
60.6% owner 39.4% renter
$26,711
$28,406
$32,348
NUMBER OF YEARS SPENT AT RESIDENCE
HOME OWNERSHIP MEDIAN INCOME
(BASED OFF OF STUDIES CONDUCTED IN 2009)
MODES OF TRANSPORTATION 52.7%
18% 17.3%
52.6% 16.6% 14.6%
52.5% 18.1% 17.4%
KEY DRIVE
CARPOOL
BUS
WALK
HOME OWNERSHIP & RESIDENTIAL STATISTICS Although the median home value of Central Lawrenceville ($52,042) is noticably higher in comparison to that of Lower ($44,468) and Upper Lawrenceville ($46,328), the median income of its residents is relatively on par with the rest of the region. Of the 86% of homes that are occupied, the ratio of owner to renter in Central Lawrenceville is fairly balanced with 51.8% of people owning their home to 48.2% who rent.
PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS
PS1.01
Bu
tler
Str eet
VACANT LOTS: LOWER LAWRENCEVILLE
ve Penn A
Butl
er S
tree
t
VACANT LOTS: UPPER LAWRENCEVILLE
St
an
PS1.02
ton
Av e
PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
LAWRENCEVILLE VACANT LOTS
LOWER
UPPER
Lots Listed: 8 24 Price/SF: $3.7 $3.14 Average Value: $4662 $13933 Average Area: 1233 SF 4432SF http://www.city.pittsburgh.pa.us/finance/real_estate/08_marketing_lots_oct.pdf
The majority of the vacant lots in Lawrenceville exist in the Upper area, with a larger square footage of land available and higher priced vacancies available. The vacant land in Upper Lawrenceville is mainly concentrated within one area as opposed to the Lower section where lots are dispersed. In lower Lawrenceville all of the vacant lots are level and have a paved street.Approximately half of the vacant lots in upper Lawrenceville are level and the other half are sloped. About 90% of the lots are on a paved street.
KEY Price
Lot Size
< $ 5000
1000SF - 4000SF
> $ 5000
over 4000SF
PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS
PS1.03
HOUSING
Pittsburgh Lower Central Upper Average Listing Price: $232,000 $124,000 $133,000 $59,000 Price/SF: $85 $72 $38 Properties for Sale: 2979 14 32 21 Properties Sold: 3794 20 31 11 Foreclosed: 2049 5 9 5 http://www.trulia.com/real_estate/Pittsburgh-Pennsylvania/
HOUSES FOR SALE BY >10K 10K 20K - 30K 80K
PS1.04
PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
BUILDING PERMIT REQUIREMENTS
Prior to the construction, enlargement, alteration, or repair of any building or structure a building permit is required. A contractor licensed by the City of Pittsburgh must make the application for building permit unless the occupier performs on his/her own one or two-family dwelling and no employees are hired. The building permit applications must be made by the owner, contractor, or authorized agent. The process includes: zoning counter, file room, engineerâ&#x20AC;&#x2122;s counter, license and cashier counter. The following information is needed: address of the job site, ownerâ&#x20AC;&#x2122;s information, check or money order, contractor registration information, constructions plans (approved by an engineer or architect), and if occupancy permit is needed a plot plan for zoning approval is required. http://www.city.pittsburgh.pa.us/BBI/html/building_permit.html
BUILDING PERMIT FEES
R-3/R-4
Commercial
R-2
New Const.
$247
$0.43/sf
$0.43/sf
Additions
$64
$0.43/sf
$0.43/sf
Alterations
$34
$78
$78
***There is a minimum of $82 for commercial and R-2 additions. The alterations cost for commercial and R-2 varies, up to $1000 is equivalent to $78. Each additional $1000 is $13, and each additional $1000 over $1 Million is $6. This is a basic measure to view the feasibility of a project, specifically if alterations and additions are worth adding to the existing structure. http://www.city.pittsburgh.pa.us/BBI/assets/10_BBI_permit_fees.pdf
SERVICE RATE FEES ELECTRICITY Duquesne Light Company $0.14/kwH NATURAL GAS Peoples Dominion 1cf of gas = 1,026 btu $12.12/mmbtu HOT WATER Fuel type: Gas $12.12/mmbtu ***Average gallons of hot water/month = 2800 gallons mmbtu/mo= gallons x .001 mmbtu/gallon (convert to mmbtu)
PROJECT SCOPE: BROAD DEMOGRAPHIC CHARACTERISTICS
PS1.05
SUN STUDIES ON PRIMARY HOUSE
SUN SHADOWS: JANUARY 9:00AM - 1:00PM - 5:00PM
SUN SHADOWS: JULY 9:00AM - 1:00PM - 5:00PM
PS2.00
PROJECT SCOPE: SUN / SHADOW DATA
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
Central Lawrenceville Topography with 5 foot contour intervals
DAYLIGHT
Because Pittsburgh is located on the windward side of the Allegheny Mountains, there is often cloud cover and many overcast days. In the winter months, only 28% to 30% of daylight hours have direct sunshine. In summer this number climbs to 55%, which is still a fairly low amount of sunshine. This brings into question the feasability of passive solar systems. [source: rssweather.com]
TOPOGRAPHY AND SLOPE
Central Lawrenceville is located on a hillside sloping northwest toward the Allegheny River. The nieghborhood itself has a fairly steep but tranversible grade, while steep slopes exist to the south and north. The western part is located on the flat lowland adjacent to the river. The direction and grade of slope can affect the exposure to sunlight of buildings, especially that of the Hill District to the south. Also, runoff patterns are directed down the north-south streets due to the slope.
SUN ACCESS
The primary case study house is facing southest. With no houses on the opposite side of the street, this means excellent access to sunlight during the morning hours year-round for rooms in the front portion of the house. These spaces already have large windows that are acceptable for solar gain the winter, but could present a problem of overheating during the summer months. The northeast facade of the house recieves no direct sunlight but also has no fenestration. This facade is ideal for allowing indirect light in the summer months while contributing little to overall heat gain. Currently, this strategy is not being utilized.
PROJECT SCOPE: TOPOGRAPHICAL DATA
PS2.01
PREVAILING WIND PATTERNS ON PRIMARY HOUSE
WIND PATTERNS
Winds are primarily from the southwest during summer and winter months but shift more westerly during mid spring and autumn. Average wind speeds vary from around 10 -12 knots in winter to 6 - 8 knots during the summer. Local conditions may modify the prevailing wind patterns and proximity to built structures, open spaces, and orientation have an effect on inidividual structures. A steep hill lies to the southwest of Lawrenceville, directing winds to the west and south. Strongest wind patterns come from the riverfront to the northwest.
WIND ROSES FOR FOUR SIGNIFICANT MONTHS
(METERS PER SECOND)
January
May
July
October
The location of the primary case study house on a relatively isolated hillside makes it highly susceptible to wind, especially southwest winds that come directly up the street. This can affect the required heating of the house in winter, but is desirable in summer for passive cooling. National Water and Climate Service
National Water and Climate Service
PS2.02
PROJECT SCOPE: WIND DATA
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
TEMPERATURE Pittsburgh is a four season climate with warm summers and cold winters. Average temperature in winter ranges from 19 to 35 degrees Fahrenheit, while summer averages 62 to 82 degrees Fahrenheit. The climate is thus heating-based, with 5968 heating degree days versus 654 cooling degree days. A heating system is required in all homes, but cooling may be completed passively to avoid constructing cooling systems. http://www.rssweather.com
PRECIPITATION Annual precipitation is 37.85 inches, falling fairly evenly across the year but slightly more in spring and less in fall. Pittsburgh also recieves around 15 inches of snow per season. Precipitation drains northwest to the Allegheny River. The slope of most of the neighborhood toward this direction as well as proximity to green areas such as the cemeteries and parks allows for several areas for water retention and drainage control. Water falling on the roof can also be collected for grey water usage in the home, further reducing runoff. http://www.rssweather.com
PROJECT SCOPE: ENVIRONMENTAL DATA
PS2.03
LOCATIONS OF HOUSING TYPOLOGY The focused typology is a two-story, single unit house with three bays of windows and a dormer on the street-facing facade. Some variations include balcony, sizes and position of windows, setback, addition of the back of the house, etc. The houses are scattered across ten streets. Different positions dictate how the owner adept their houses. Because Upper Lawrenceville is centered on industry, the majority of this housing typology can be found in Lower and Central Lawrenceville The primary materials used in this typology are bricks and shingles with various exterior finishing. The prices of the houses are acquired from the Allegheny County tax assessment web site. Prices may not match the present day value since appraisals were taken place in the 1900â&#x20AC;&#x2122;s. Number twenty is the primary house with east-west axis. Number six is the secondary house with north-south axis. Both houses are detached masons rowhouse with a vacent lot on one side.
14 15 11
16
12
9
13 10 7
3
1
4
8 5 2
6
18 17
20 19
PS3.00
PROJECT SCOPE: HOUSING LOCATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
1. 119 41st Street North - South axis 2,050 sq. ft. Brick & Shingle $34,400
2.
5. 113 42nd Street North - South axis 1,020 sq. ft. Brick & Shingle $22,700
6.
124 42nd Street North - South axis 1,245 sq. ft. Brick & Shingle $ 83,400
SECONDARY HOUSE 148 42nd Street North - South axis 2,400 sq. ft. Brick & Shingle
3.
109 42nd Street North - South axis 1,028 sq. ft. Brick & Shingle $24,800
7.
138 44th Street North - South axis 2,286 sq. ft. Brick & Shingle $23,500
ARC48_550
4. 111 42nd Street North - South axis 989 sq. ft. Brick & Shingle $18,600
8. 140 44th Street North - South axis 2,286 sq. ft. Brick & Shingle $20,500.
PROJECT SCOPE: HOUSING LOCATION
PS3.01
9. 150 44th Street North - South axis 1,296 sq. ft. Brick & Shingle $31,600
10. 138 44th Street North - South axis 2,286 sq. ft. Brick & Shingle $23,500
11. 133 45th Street North - South axis 2,000 sq. ft. Brick & Shingle $48,200
12.
13.
14. 133 46th Street North - South axis 2,150 sq. ft. Brick & Shingle $34,100
15.
16. 175 46th Street North - South axis 2,000 sq. ft. Brick & Shingle $53,100
168 46th Street North - South axis 2,000 sq. ft. Brick & Shingle $66,100
PS3.02
PROJECT SCOPE: HOUSING LOCATION
127 46th Street North - South axis 2,100 sq. ft. Brick & Shingle $ 38,100
143 45th Street North - South axis 1,120 sq. ft. Brick & Shingle $35,800
Pittsburgh Program for the Adaptive Transformation of Community Housing
17. 306 45th Street North - South axis 2,376 sq. ft. Brick & Shingle $23,900
18.
272 46th Street North - South axis 2,000 sq. ft. Brick & Shingle $37,700
19. 302 46th Street North - South axis 5,060 sq. ft. Brick & Shingle $30,000
ARC48_550
20.
PRIMARY HOUSE 4627 Bancroft Street East - West axis 2,640 sq. ft. Brick & Shingle $31,900
Parcel ID 0049-C-00276-0000-00\ Municipality 109 PIttsburgh - 9th Ward
PROJECT SCOPE: HOUSING LOCATION
PS3.03
City of Pittsburgh Maps
PITTSBURGH ZONING CLASSIFICATIONS Residential Commercial Landscape Educational Industrial
EMI - Educational/medical institution GI - General Industrial H - Hillside LNC - Local Neighborhood Commercial PO - Parks and Open Space R1A-H - Single-Unit Attached Residential High Density R1A-VH - Single-Unit Attached Residential Very High Density R1D-H - Single-Unit Detached Residential High Density RM-M - Multi-Unit Residential Moderate Density UI - Urban Industrial
PS4.00
PROJECT SCOPE: LAND USE AND ZONING REQUIREMENTS
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
CITY OF PITTSBURGH LAND USE STIPULATIONS
Lawrenceville consists of residential, commercial, landscape, educational and industrial zones. Of which landscape, residential and industrial zones occupy the most square footage. Industrial zone surrounds the river. The commercial zone locates on either sides of Butler Street. Residential zones are scattered among commercial and park areas. The primary house locates in the R1A-H zone. The primary house is directly adjacent to a big open green space. Secondary house locates in the R1A-VH zone. It is sandwiched between industrial and commercial zones. Code of Ordinances: City of Pittsburgh, Pennsylvania Ord. No. 39-2009, enacted . 1, 2010
LANDUSE FOR PRIMARY HOUSE R1A-H - Single-Unit Attached Residential
Min Lot Size Min Lot Size per Unit Min Front Setback Min Rear Setback Min Exterior Sideyard Setback Min Interior Sideyard Setback Max Height stories)
1,800 s.f. 750 s.f. 15 ft 15 ft 15 ft 10 ft 40 ft (not to exceed 3
LAND USE FOR SECONDARY HOUSE
R1A-VH - Single-Unit Attached Residential Very High Density
Min Lot Size Min Lot Size per Unit Min Front Setback Min Rear Setback Min Exterior Sideyard Setback Min Interior Sideyard Setback Max Height stories)
1,200 s.f. 400 s.f. 5 ft 15 ft 5 ft 10 ft 40 ft (not to exceed 3
PROJECT SCOPE: LAND USE AND ZONING REQUIREMENTS
PS4.01
LOT: 4627 BANCROFT STREET | PRIMARY HOUSE STREET FRONT SETBACK & UTILIZATION CHARACTERISTICS
A. Front setback less than 5 feet in depth, entrance at street level B. Front setback less than 5 feet in depth, elevated entrance C. Front setback between 5 and 10 feet in depth, entrance at street level D. Front setback between 10 and 20 feet in depth, front yard utilization E. Front setback 20 feet or greater in depth F. Lot usage not oriented towards the street in reference G. Vacant lot, no site usage
Unit and Side Setback Charcteristics
PS5.00
PROJECT SCOPE: SITE UTILIZATION
1. Single-unit, detached with side setbacks of at least 3 feet on either side 2. Multi-unit, attached
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
Front and Rear setbacks and space utilization No front yard utilization, while the back of house is kept as yard space. North side of house is directly adjacent to an unused plot of city land with no side setback.
Site Information:
Lot Depth: 120 feet Lot Width: 25 feet Front Setback: 2 feet Rear Setback: 50 feet Side Setback: 10 feet
Side setback and space utilization A 10 foot side setback in between the house and its neighbor has been partitioned out and paved with the clear intention for it to be used as a carport. However, because the street is more remote and does not see much traffic, people have come to park their cars along the street rather than in the narrow spaces in bvetween each house to allow for easier access. The space has been fenced off and utility lines and air-conditioning units have been allowed to protrude out into the space that once would have been reserved for the automobile.
PROJECT SCOPE: SITE UTILIZATION
PS5.01
LOT: 148 43RD STREET | SECONDARY HOUSE Street Front Setback & Utilization Characteristics:
A. Front setback less than 5 feet in depth, entrance at street level B. Front setback less than 5 feet in depth, elevated entrance C. Front setback between 5 and 10 feet in depth, entrance at street level D. Front setback between 10 and 20 feet in depth, front yard utilization E. Front setback 20 feet or greater in depth F. Lot usage not oriented towards the street in reference G. Vacant lot, no site usage
Unit and Side Setback Charcteristics:
PS5.02
PROJECT SCOPE: SITE UTILIZATION
1. Single-unit, detached with side setbacks of at least 3 feet on either side 2. Multi-unit, attached
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
Side setback and utilization As a detached, single-unit typology, the house has a narrow 5 foot clearance between it and the structure on its adjacent lot. Because of the limited width and accessibility of the space, this alley is rarely inhabited. Instead, it is utilized mainly as a service corridor along which to run utility lines and store garbage so as to keep them hidden when viewed from a street front perspective.
Front and Rear setback and utilization The house is set 10 feet back from the side walk and 20 feet from its neighboring look in the back. This leaves a decent amount of space to be utilized in both the front and back yards. The front yard is currently being utilized as a garden space, which not only provides shade but also serves to screen the front of the house, creating a good amount of privacy on an otherwise densely packed residential block.
Site Information
PROJECT SCOPE: SITE UTILIZATION
Lot Depth: 80 feet Lot Width: 30 feet Front Setback: 10 feet Rear Setback: 20 feet Side Setback: 5 feet
PS5.03
PRIMARY LOT: 4627 BANCROFT STREET
LAND USE | R1A-H High Density Subdistrict: Minimum Lot Size: 1,800 square feet Minimum Front Setback: 15 feet Minimum Rear Setback: 15 feet Minimum Exterior Sideyard Setback: 15 feet Minimum Interior Sideyard Setback: 5 feet Max Height: 40 feet, not to exceed 3 stories
SITE UTILIZATION Lot Depth: 120 feet Lot Width: 25 feet Front Setback: 2 feet Rear Setback: 50 feet Side Setback: 10 feet (left), 0 feet (right)
SITE UTILIZATION DEVIATION The house is incompliant with R1A-H land-use stipulations on its Northeast and Southeast facades. The code requires a 15 foot front yard setback, however only a 2 foot setback exists for the current housing footprint. The side setback is also incompliant with the 5 foot minimum setback requirement as stipulated by land-use code. Instead the house sits right along the lot boundaries of the vacant piece of city owned land.
PS6.00
PROJECT SCOPE: LAND USE / SITE UTILIZATION DEVIATION
HEIGHT
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
SECONDARY LOT: 148 43RD STREET
LAND USE | R1A-VH Very High Density Subdistrict
Minimum Lot Size: 1,200 square feet Minimum Front Setback: 5 feet Minimum Rear Setback: 15 feet Minimum Exterior Sideyard Setback: 5 feet Minimum Interior Sideyard Setback: 5 feet Maximum Height: 40 feet, not to exceed 3 stories
SITE UTILIZATION
Lot Depth: 80 feet Lot Width: 30 feet Front Setback: 10 feet Rear Setback: 20 feet Side Setback: 5 feet (left), 4 feet (right)
SITE UTILIZATION DEVIATION In its existing condition, the house complies with the R1A-VH stipulations on all sides except on its Northwest faรงade. The land use code sets down a 5 foot minimum side setback, but the house is only set back 4 feet on its North-west side, leaving a one foot section that protrudes into the no-build space between the house and its adjacent vacant lot.
PROJECT SCOPE: LAND USE / SITE UTILIZATION DEVIATION
PS6.01
CHARACTERISTICS OF PRIMARY HOUSE LOCATION This house is located on the boundary between the cemeteries and the residential area. The front of the house faces a stone wall that separates the houses from the St. Maryâ&#x20AC;&#x2122;s cemetery. On the northeast side of the house faces the Allegheny Cemetery, and the southwest side and the back side of the house face other residential buildings.
N
Single loaded
Elevation of the street the house is located
The street or the stone wall that the house is facing
PS7.00
PROJECT SCOPE: HOUSING CONDITION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
CHARACTERISTICS OF SECONDARY HOUSE LOCATION This house is surrounded by similar houses all around. Its front faces another front porch of a house. The northwest side of the house faces a garden next door and is also open to the empty lot. This house is located in a dense residential area.
N
Double loaded
Elevation of the street the house is located
The street the front porch of the house is facing
PROJECT SCOPE: HOUSING CONDITION
PS7.01
VARIABLES ACROSS THE TYPOLOGICAL INVENTORY
SINGLE FRONT-FACING DORMER
FRONT-FACING WINDOW CONDITIONS
EXTERIOR FINISH MATERIAL
FRONT DOOR CONDITIONS
PS7.02
PROJECT SCOPE: HOUSING CONDITION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
EXISTING CONDITIONS With a double brick construction, the building envelope seems stable and sturdy despite its age. The owner of the house replaced the old windows with new double glazed windows within the past ten years, while other openings have been covered up with brick. There are cracks between the old and newly filled in brick. The gutters need to be redirected; currently they extend directly onto the lawn. Newly installed double glazed windows; no
Lose shingles overhead
The interior of the house has been renovated by the owner and does not require further rennovation. The owner mentioned that the chimney leaks inside the house, which needs to be fixed. Originally there were fire places in every room, but now all of them are blocked from inside. The porch was constructed by the father of the resident a few decades ago. Its original wood construction was later reinforced with brick. Due to years of exposure to severe weather and the elements, the porch is currently in poor condition. The wood overhead is rotting and warping, and the shingles have come loose. The porch needs to be fitted with a new roof and drainage system. Grass exists only on the cemetary side of the house, and there are no trees around the house. There is a small stone decoration in front that requires little maintenance. The large backyard is not well maintained, and is currently being used as storage space for garbage and machinery.
Deserted backyard
Low maintanence stone element
Leaking chimney
Gutter condition
Existing porch in poor condition No trees or vegetation on site. Only grass from the cemetary PROJECT SCOPE: HOUSING CONDITION
PS7.03
PRIMARY HOUSE: MATERIAL CONDITIONS Exterior: Double wythe brick construction Roof: Asphalt shingles Window: Double glazed, operable Porch: Open brick construction Building Footprint: 800 sq. Total Window area: 191.5 sq. Total Brick envelop area: 2834.5 sq. Total Number of Rooms: 6
Double wyth brick exterior wall
AREAS OF MODIFICATION Porch addition; Room addition (rear); Louvers on the porch; Window extension on the 1st floor; New window installation; brick enclosures on side windows.
DOUBLE WYTHE BRICK WALL CONSTRUCTION
Metal cladding and gutter
CEILING JOIST RAFTER
Decorative metal cladding
EXTERIOR
INTERIOR
DOOR FRAME
FLOORING FLOOR JOIST REINFORCED CONCRETE PORCH SLAB
BEARER
Asphalt shingle roofing
REINFORCED CONCRETE
PS8.00
PROJECT SCOPE: MATERIALS AND CONSTRUCTION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
PRIMARY HOUSE: FORMS OF MODIFICATION
dormer
additional room
porch
The porch and room addition to the original house
Decreased size of openings by walling up windows and doors
Window > expansion
Operable louvers installed on the porch
PROJECT SCOPE: MATERIALS AND CONSTRUCTION
PS8.01
SECONDARY HOUSE: MATERIAL CONDITIONS CONSTRUCTION Metal is used significantly throughout the exterior along with brick. Metal cladding on the porch roof, metal gutters along the roof edges, and metal shutters on the porch. However these are not the original materials, they were later added to the house. The house structure is wood frame construction with brick exterior. The porch, which was later added is also wooden structure.
Majority of the exterior is brick.
Diagram by Rural Building http://www.ruralbuilding.com.au/pages/brick_veneer.asp
Metal details along the porch
Asphalt shingles are also part of the materials, but it is only used on the side of the gabled dormer dormer
FORMS OF MODIFICATION Porches were added to the original form in the front of the house as well as the back of the house. Gabled dormer is also a later addition to the house. The metal shutters on the porch is the most recent modification to the house. front porch
PS8.02
PROJECT SCOPE: MATERIALS AND CONSTRUCTION
back porch
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550 HEATING COAL
Coal Chute
One of our housing studies was constructed around 1900 and originally used coal as the main heating method. A coal chute can be seen from the porch, this was originally designed to have coal be directly transferred to the coal storage area and furnace located in the basement. Most homes that date back to this time would have used coal before updating the homes heating system.
GAS RADIATOR SYSTEM
Radiator
STEAM AND WATER Homes in the Lawrenceville area currently use a gas radiator heating system using. Either steam (which was specifically used in house 1), or water is circulated through exposed pipes. Radiators installed in these housing typologies usually exist in front of windows to help cut the harsh cold weather air that infiltrates through windows in the winter. Steam radiators are rather energy inefficient because of the time lag between turning on the system and the arriving of steam. Depending on when the heating system was last maintained, radiators can run at about only 40-50% efficiency. Ways to improve heat transfer throughout the room would be to place a reflector behind the radiator so the hot air reflects back into the room. Other possibilities for heating in the Lawrenceville area would be electric baseboard heaters. Since most homes date back to the 1940â&#x20AC;&#x2122;s a central air system would not have been in place unless in a major retrofit occurred.
Radiator Reflector
COOLING AIR CONDITIONING UNIT
The main method of cooling in the residences of Lawrenceville is through the addition of a window air conditioning unit. Our first house had one placed on the second floor, the second house had two, one on the first floor and one on the second floor. Window AC units make for an easy retrofit for a home and offer the flexibility of turning on the unit when using a single room.
AC Window Unit
PROJECT SCOPE: HEATING AND COOLING SYSTEMS
PS9.00
The front porch was originally wood but was replaced with a brick one and contains a louver system facing the vacant lot for passive ventilation control on the porch. Heating was originally by coal furnace. The chute that used to deliver coal still exists below the front porch of the house, though no longer in use. There are two chimneys along the eastern wall of the original house and one on the west in the rear addition inferring possible location of the heating system inside. There is no cooling system, except for air conditioning units the owner placed in the windows.
The main case study house is located at 4627 Bancroft Street, near a part of Allegheny Cemetery. It is relatively isolated, at the end of a dead end street with a large vacant area directly next to it. The facade faces southeast and the primary orientation is East-West. The house was built in 1900 and contains 6 rooms, 3 bedrooms, and 1 bath. It consists of an original house and a later extension to the rear. The original house is three stories over a basement. The third floor is within the eave of the roof with one dormer over the front. The second floor fenestration contains three windows on the street facade. The original house was expanded at an unknown time to the rear on the first two stories and basement. The large rear extension nearly doubles the living area of the house, to 1,472 square feet. It is made entirely of brick construction, with no insulation except for panels added to the interior of some rooms. While there several windows on the two sides that would normally abut similar row house types, changes in the brick work imply windows were larger at one time, and back doors have been relocated from the side to the rear.
EXISTING SOUTH ELEVATION 1/8” = 1’-0”
PS10.00
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
EXISTING SOUTH AXONOMETRIC 1/8” = 1’-0”
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - AXONOMETRIC
PS10.01
EXISTING WEST ELEVATION 1/8” = 1’-0”
PS10.02
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - ELEVATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
EXISTING EAST ELEVATION 1/8” = 1’-0”
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - ELEVATION
PS10.03
EXISTING BASEMENT PLAN 1/8” = 1’-0”
PS10.04
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - PLAN
EXISTING FIRST FLOOR PLAN 1/8” = 1’-0”
Pittsburgh Program for the Adaptive Transformation of Community Housing
EXISTING SECOND FLOOR PLAN 1/8” = 1’-0”
ARC48_550
EXISTING ATTIC PLAN 1/8” = 1’-0”
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - PLAN
PS10.05
EXISTING NORTH-SOUTH SECTION 1/8” = 1’-0”
PS10.06
PROJECT SCOPE: TYPOLOGY CASE STUDY BUILDING - SECTION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
Adaptive Transformation
R301- Design criteria As stipulated in R301.3 of the 2009 International Residential Code the residence shall comply with part 3, that the masonry walls must be at a maximum height of 12 feet plus a height of floor framing to not exceed 16 inches. An additional 8 feet is permitted for gable and end walls. The primary residence meets section R301.3 as the floor to ceiling heights have been lowered to 8 feet in recent renovations.
R303.7 Required glazed openings As stipulated in R303.7 of the 2009 International Residential Code (IRC2009), glazing under code requirements must open directly to a street, public alley, a yard, or a court. The residence meets this condition as the glazing opens up to the street on the Southeast face, the side yard along the East and the neighboring lot on the West.
>40% of Porch Exterior open =Sunroom
12’ MAX.
(CLEAR HEIGHT)
>7’ Height
EXIT
16” MAX.
(FLOOR HEIGHT)
R303.1 Habitable rooms As stipulated in section 303.1 of the 2009 International Residential Code (IRC2009), all occupying rooms must have glazing area of more than 8 percent of the floor area of the room. Rooms shall be naturally ventilated through windows, doors, louvers or other approved openings to natural air. Openings either should perform as access or be controllable by the occupants. The area of operable openings must be at least 4 percent of the ventilated floor area. The listed exception of section R303.1 pertains to a sunroom addition which is defined as a one-story structure attached to a dwelling with a glazing area in excess of 40 percent of the gross area of the structure’s exterior walls and roof. Sunroom additions are allowed for natural ventilation if in excess of 40 percent of the exterior sunroom walls are open or enclosed only by insect screening.
ELEVATION
GLAZING AREA > 8% OF FLOOR AREA
The proposed condition of the alteration to the residence discussed in this project will meet section 303.1 as the glazing will total % of the floor area of the room. The operable openings total % of the floor area.
OPERABLE GLAZING AREA > 4% OF FLOOR AREA
FLOOR AREA
8% OF FLOOR AREA 4% OF FLOOR AREA
PLAN
CA1.00
CODE ANALYSIS
Pittsburgh Program for the Adaptive Transformation of Community Housing
R304 Minimum Room Areas As stipulated in section R304 of the 2009 International Residential Code there should be a minimum of one habitable room in every home of at least 120 square feet of gross floor area. The area of other habitable rooms must be larger than 70 square feet, except for kitchens. Every wall shall be wider than 7 feet. The residence meets this condition as the porch extension is 105 square feet, which is larger than the 70 sqaure feet minimum requirement for habitable area. 310.1- Residential Group R As stipulated in section 310.1 of the 2009 International Building Code the occupancy classification of the residences discussed in this project meet an R-3 classification as a primarily permanent residence in nature. The residential occupancy does not meet group R-1, R-2, or R-4 classification as they are either transient in nature or contain multiple housing units.
Must have at least 1 habitable room that is greater than 120sqft.
ARC48_550
Zoning classification: r-1 As stipulated in the zoning classification listed in the Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009 the primary residence is located in an R1-AH high density residential area of Lawrenceville and the secondary home is located in an R1A-VH zone for a very high dense residential area. As stipulated in the Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009 the zoning requirements of a residence located in R1-AH are as follows: Min Lot Size 1,200 s.f. Min Lot Size per Unit 400 s.f. Min Front Setback 5 ft Min Rear Setback 15 ft Min Exterior Sideyard Setback 5 ft Min Interior Sideyard Setback 10 ft Max Height 40 ft (not to exceed 3 stories) Zoning Classifications Continued As stipulated in the Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009 the zoning requirements of a residence located in R1A-VH are as follows: Min Lot Size 1,200 s.f. Min Lot Size per Unit 400 s.f. Min Front Setback 5 ft Other habitable rooms Min Rear Setback 15 ft
(excluding >120fqft. room) must be greater than 70sqft.
>120sqft.
>70sqft. 7â&#x20AC;&#x2122; MIN
7â&#x20AC;&#x2122; MIN.
The primary residence located on 4627 Bancroft Street located in a R1-AH area meets the Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009 for minimum lot size, and rear and side setbacks. This residence does not meet the front lot setback as stated in the Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009. The minimum lot coverage is met as the lot is 3000 square feet total. The residence meets the requirements for rear setback as it is 50 feet. The interior sideyard setback is met as it is currently 10 feet. The front setback does not meet the zoning code as it is only 2 feet setback from the sidewalk, the minimum requirement is a 15 foot setback. The residence 148 43rd Street situated in an R1A-VH meets Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009 for minimum lot size, and front and rear setbacks but does not meet code for the interior sideyard setback. The residence meets the minimum lot coverage as it is 2400 square feet total. The front setback of the home is 10 feet which meets the minimum front setback of 5 ft. The rear setback is 20 feet which meets the minimum requirement of 15 feet. The side setback on the interior side is 5 feet which does not meet the minimum requirement for interior sideyard of 10 feet.
CODE ANALYSIS
CA1.01
Zoning Classification Continued No. 39-2009. The minimum lot coverage is met as the lot is 3000 square feet total. The residence meets the requirements for rear setback as it is 50 feet. The interior sideyard setback is met as it is currently 10 feet. The front setback does not meet the zoning code as it is only 2 feet setback from the sidewalk, the minimum requirement is a 15 foot setback. The residence 148 43rd Street situated in an R1A-VH meets Code of Ordinances for the City of Pittsburgh Ord. No. 39-2009 for minimum lot size, and front and rear setbacks but does not meet code for the interior sideyard setback. The residence meets the minimum lot coverage as it is 2400 square feet total. The front setback of the home is 10 feet which meets the minimum front setback of 5 ft. The rear setback is 20 feet which meets the minimum requirement of 15 feet. The side setback on the interior side is 5 feet which does not meet the minimum requirement for interior sideyard of 10 feet. AJ601.2 Wall and ceiling finish As stipulated in AJ601.2 of the 2009 International Building Code (IBC2009), the interior finish of walls must satisfy R302.8 Flame Spread index and Smoke-developed Index. R302.8 states that wall and ceiling finishes must have a flame index of less than 200 and smoke-developed index number of less than 450. Interior finishes must be tested with either ASTM E 84(test for surface burning characteristics of building materials) or UL23.4 (test for surface burning characteristics of flooring, floor covering, and miscellaneous materials). The existing condition of the home includes a double wythe masonry wall of a flame index of 0 which meets code AJ601.2. The modification of the residences mentioned in this project will include 5/8” gypsum board finishing material on walls and ceilings that will gain insulation. The flame index of 5/8” gypsum board is 15, which meets code AJ601.2
Exterior door
Ext.
Min. 36” landing
Int.
Section 602.3 As stipulated in 602.3 of the 2009 International Building Code Section the residences discussed in this project follow Type III building classification. The exterior of the building must be constructed of masonry walls which are noncombustible and the interior of the building must meet code. The fire-rating of the exterior baring walls must be at least 2 hours. The construction has to follow a brick and joist structure that has masonry load bearing walls. The floors and other structural framework are made of wood or of another combustible material. The residences meet section 602.3 as the exterior construction is noncombustible masonry with a fire-rating of at least two hours. The interior construction is composed of lumber joists and studs. As stipulated in section 602 of the International Building Code the fire rating resistance is classified as “B” since all the structural member are un-protected and have no additional fire rated coating of cover. The residences are classified as “B” construction due to the lack of fire rating cover on interior structural members. R311- Means of egress As stipulated in R311.1 of the 2009 International Residential Code all stairways, ramps, and exits shall comply with criteria governing means of egress for the projects described in this document. A continuous and unobstructed path of vertical and horizontal egress travel from the interior to the exterior of the dwelling must be provided. As stipulated in section R311.2 of the 2009 International Residential Code at least one egress door is provided in the existing residences as described in this document. The door complies with a side-hinged that provides a minimum clear width of 32 inches. The door opens 90 degrees and is at least 78 inches in height from the top of the threshold to the bottom. As written in section R311.3 the residence complies with proper floor landings at exterior doors provided that the landing is a flat slope and is 36 inches in the direction of travel.
Min. 36” landing
Continuous and unobstructed circulation between ext. and int. throughout the house
Porch
Living Room
Kitchen
Dining Room Half fBBath
CA1.02
CODE ANALYSIS
Pittsburgh Program for the Adaptive Transformation of Community Housing
R311.8.1 Means of Egress- Ramp As stipulated in section R311.8.1 of the 2009 International Residential Code, the maximum slope of a ramp shall be 1 vertical to 12 horizontal units (8.3 percent slope).
HANDRAIL DIAMETER 1.25” < x < 2”
The ramp defined between the living room extension and the existing living room with a height differential of 4” meets code R311.8.1 as it slopes 4 vertical inches over 48 horizontal inches which is calculated at 8.3 percent slope. R311.7.7.3 Means of Egress- Grip Size As stipulated in section R311.7.7.3 of the 2009 International Residential Code a handrail must meet the graspability requirements in either a circular or non-circular form. A circular cross section shall have an outside diameter between the dimensions of 11/4 inches (32 mm) and 2 inches (51 mm). A non-circular railing shall have a perimeter dimension between 4 inches (102 mm) and 61/4 inches (160 mm) with a maximum cross section of dimension of 21/4 inches (57 mm). The railing provided in the residence meets section R311.7.7.3 as it is 2” x .5” rectalinear. R 312.2 Guard- height As stipulated in Section R312.2 of the 2009 International Residential Code, a guard is required along an open-sided walking surface such as a stairway, ramp, or landing that is located more than 30 inches (762 mm) measured in the vertical direction.
ARC48_550
x
a a+b+c+d = y b PERIMETER 4” < y < 6.25” d c
N1101.4 Building thermal envelope insulation As stipulated in N1101.4 of the 2009 International Residential Code (IRC2009), for insulation pieces that have a width larger than 12 inches (305mm) shall have R-value identification mark indicated by the manufacturer. The insulation installer should indicate certification, manufacturer type, and R-values of the installations, and he/she must sign, date, and post the certificate at the installation site. The addition of insulation within the homes specified in this project include Owens Corning Pink 12 in. x 16-1/4 in. x 4 ft. R38 Fiberglass Insulation and Super Tuff R13 2 in. 4 ft. x 8 ft. Polyisocyanurate Rigid Foam Insulation are clearly marked on the product. The installer of the insulation will sign the certificated required of code N1101.4 upon installation of the product in the residences mentioned in this project.
A guard will be provided along the 4” vertical ramp located between the addition and existing living room of the residence discussed in this project at 36” above the finished surface. Along the front entrance step sequence of the residence a guard will be constructed 36” above the finished surface in order to meet section R312.2.
N1102.1 Insulation and fenestration criteria As stipulated in N1102.1 of the 2009 International Residential Code (IRC2009), the building thermal envelope shall meet the requirements of Table N1102.1 based on the climate zone specified in this table. Pittsburgh, Pennsylvania is within climate zone 5 and requires insulation values of U value .35 for fenestration and U value of .60 for skylights. The ceiling must be at least R38 and the masonry walls must meet an R13 insulation value.
R312.3 Guard- Opening limitations. As stipulated in section R312.3 of the 2009 International Residential Code guards shall not have any openings that allow a 4 inch diameter sphere to pass through.
The existing conditions of the homes discussed in this project do not meet the floor and wall insulation requirements stated in code N1102.1. The proposed adaptation of the specified homes and addition of insulation of R13 2” rigid foam insulation to the walls and R38 12” fiberglass insulation to the basement ceiling and the second floor ceiling will meet code N1102.1
Exceptions: 1. The triangular openings at the open side of a stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches (153 mm) in diameter.
x
Climate Zone 5 Fenestration U Factor: .35 Skylight U Factor: .60 Ceiling R Value: 38 Wood Frame Wall R Value: 19 or 13 + 5 Mass Wall R Value: 13 Floor R Value: 30t Basement Wall R Value: 10/13 Slab R Value and Depth: 10, 2ft Crawl Space Wall R Value: 10/13
36”
12
1
1:12 OR 8.3% SLOPE
CODE ANALYSIS
CA1.03
02 SITE CONSTRUCTION
06110-06 2”x 12”x 4’7” Lumber Quantity 4 to be used in awning sub-frame (Material Product information same as 06110-05)
04 MASONRY
06110-07 2”x 12”x 4’4 3/16” Lumber Quantity 2 to be used for awning sub-frame (Material Product information same as 06110-05)
02250 - Shoring and Underpinning 02250-01 Shoring for brick façade 04060 - Masonry Mortar 04080 - Masonry Anchorage and Reinforcement 04081 - Masonry Anchorage
05 METALS
05120 - Structural Steel 05120-01 Steel lintel
06 WOODS AND PLASTICS 06110 - Wood Framing 06110-01
4”x 4”x 7’8” Lumber Quantity 4 to be used for columns in porch framing system Can be purchased from big box store Manufacturer: Millstead Wood Species: Southern Yellow Loblolly Pine Actual Depth/Thickness : 3.5 in Assembled Depth (in.) : 144 in Assembled Height (in.) : 4 in Assembled Width (in.) : 4 in Item Weight : 54.4 lb Paint Type Recommended : Oil Based & Latex Plywood Type : Plywood Sheathing Pressure Treated : Yes MFG Model # : 258132 MFG Part # : 258132
06110-02 4”x 4”x 5’6” Lumber Quantity 3 to be used for columns on top of the 2.5’of brick (Material Product information same as 06110-01) 06110-03 4”x 4”x 14’ Lumber Quantity 2 to be used for beam in porch framing system (Material Product information same as 06110-01) 06110-04 4” x 4”x 7’ 3 ½” Lumber Quantity 2 to be used for beam in porch framing system (Material Product information same as 06110-01) 06110-05 2”x 12” x 10’ Lumber Quantity 4 to be used in awning main frame Can be purchased from big box store Manufacturer: Millstead Wood Species: Spruce and Lodgepole Pine Actual Depth/Thickness : 1.5 in Assembled Depth (in.) : 192 in Assembled Height (in.) : 1.5 in Assembled Width (in.) : 11.25 in Item Weight : 52.1 lb Paint Type Recommended : Oil Based & Latex Pressure Treated : No MFG Model # : 212SE.16 MFG Part # : 212SE.16
SP1.00
06110-08 2” x 6” x 4’7” Lumber Quantity 10 to be used for awning sub frame Can be purchased from big box store Manufacturer: Millstead Actual Depth/Thickness : 1.5 in Assembled Depth (in.) : 1.5 in Assembled Height (in.) : 5.5 in Assembled Width (in.) : 5.5 in Nominal Length : 120 in Item Weight : 18.33 lb Paint Type Recommended : Oil Based & Latex Pressure Treated : No MFG Model # : 161721 MFG Part # : 161721 06110-09 2” x 6” x 4’4 3/16” Lumber Quantity 5 to be used for awning sub frame (Material Product information same as 06110-08) 06110-10 2” x 6” x 6’8½” Lumber Quantity 4 for window frame along western face of porch (Material Product information same as 06110-08) 06110-11 2” x 6” x 5’5 Lumber Quantity 6 for window frame along western face of porch (Material Product information same as 06110-08) 06110-12 2” x 6” x 4’11” Lumber Quantity 2 for window frame along eastern face of porch (Material Product information same as 06110-08) 06110-13 2” x 6” x 4’6” Lumber Quantity 2 for window frame along eastern face of porch (Material Product information same as 06110-08) 06110-14 2” x 4” x 16’ Lumber Quantity 16 for trellis structure on porch Can be purchased from big box store Manufacturer: Millstead Actual Depth/Thickness : 1.5 in Assembled Depth (in.) : 1.5 in Assembled Height (in.) : 3.5 in Nominal Length : 192 in Item Weight : 29.328 lb Paint Type Recommended : Oil Based & Latex Pressure Treated : No MFG Model # : 161683 MFG Part # : 161683
SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND
Pittsburgh Program for the Adaptive Transformation of Community Housing
06110-15 2” x 4” x 7’8” Lumber Quantity 6 for outswing door frame Can be purchased from big box store Manufacturer: Millstead Actual Depth/Thickness : 1.5 in Assembled Depth (in.) : 1.5 in Assembled Height (in.) : 3.5 in Nominal Length : 120 in Item Weight : 18.33 lb Paint Type Recommended : Oil Based & Latex Pressure Treated : No MFG Model # : 161659 MFG Part # : 161659 06110-16 2” x 4” x 10’ 7 3/4” Lumber Quantity 1 for porch railing Can be purchased from Home Depot in East Liberty Manufacturer: Millstead Actual Depth/Thickness : 1.5 in Assembled Depth (in.) : 1.5 in Assembled Height (in.) : 3.5 in Nominal Length : 144 in Item Weight : 22.0 lb Paint Type Recommended : Oil Based & Latex Pressure Treated : No MFG Model # : 161667 MFG Part # : 161667 06110-17 2” x 4” x 4.4’ Lumber Quantity 1 for porch railing (Material Product information same as 06110-15) 06110-18 2” x 4” 4.8’ Lumber Quantity 1 for porch railing (Material Product information same as 06110-15) 06110-19 2”x 4” x 2.6’ Lumber Quantity 1 for porch railing (Material Product information same as 06110-15) 06110-20 2” x 4” x 3’ Lumber Quantity 1 for porch railing (Material Product information same as 06110-15) 06110-21 .5” x .5”’ x 1.9’ Lumber Quantity 34 for post railing 06110-22 4” x 4” x 2.4’ Lumber Quantity 3 for post railing (Material Product information same as 06110-01) 06110-23 2” x 4” x 7’11 1/2” Lumber For spacer between the brick and insulation (Material Product information same as 06110-15) 06110-24 2” x 4” x 5’6” Sidelight glazing frame
ARC48_550
07 THERMAL AND MOISTURE PROTECTION
07210 - Building Insulation 07210-01 2” Polyurethane Rigid Foam Insulation QUANTITY Can be purchased from Home Depot in East Liberty Manufacturer: Super Tuff Assembled Depth (in.) : 2 in Assembled Height (in.) : 96 in Assembled Width (in.) : 48 in Coverage Area (sq. ft.) : 32 ft² R Value : 13.0 MFG Model # : 1361 MFG Part # : 1361 07210-02
12 in. x 24 in. x 4 ft. R38 Batt Fiberglass Insulation Can be purchased from Home Depot in East Liberty 64 sq. ft. coverage area Assembled Depth (in.) : 48 in Assembled Height (in.) : 12 in Item Weight : 36 lb Vapor Retardent : Yes MFG Model # : 488462 MFG Part # : E57
07240 - Exterior Insulation and Finish System 07240-01 DAP 10.1 oz. Alex Plus All-Purpose Caulk (12-Pack) Can be purchased from Home Depot in East Liberty Latex and silicone formulation accommodates seasonal expansion and contraction Can be used inside or outdoors on a variety of surfaces Can be painted or stained Mold- and mildew resistant Applies easily with a standard caulking gun Cleans easily with soap and water MFG Model # : 7079818656 MFG Part # : 7079818656 07715 - Gutter and Downspout Accessories 07715-01 Amerimax 16 ft. Aluminum Gutter Can be purchased from Home Depot in East Liberty Heavy-weight, rust-free aluminum construction for durability low maintenance Assembled Depth (in.) : 192 in Assembled Height (in.) : 3.5 in Assembled Width (in.) : 5 in Item Weight : 3.92 lb MFG Model # : 2600200192 MFG Part # : 2600200192 07715-02 Water bottle rainwater collector 07715-03 Metal channel clip to attach gutter to brick
SITE CONTEXT: EXISTNG ASSESTS AND LIABILITIES
SC1.01
08 DOORS AND WINDOWS
08210 - Wood Frames 08210-01 3’ 1-5/8” W x 6’ 10” Architectural Rectangle Hinged Door H-400 Quantity 1 for front elevation 08350 - Folding Doors and Grilles 08350-01 3’-2 ¼” x 6’ 10” Anderson Outswing Folding Door Two Panel 2L Quantity 1 for front elevation 8350-02 3’-2 ¼” x 6’ 10” Anderson Outswing Folding Door Two Panel 2R Quantity 1 for front elevation 08550 - Wood Windows 08550-01 5’-4 13/16” x 4’ Andersen casement window 400c255 Quantity 2 for west elevation 08550-02 5’ -4 13/16” x 2’ -4 3/8”Andersen casement window 400cw155 Quantity 2 for west elevation 08550-03 4’- 4 13/16” x 2’ – 4 3/8” Anderson casement window 400cw145 Quantity 2 for east elevation 08550-04 1’ x 4’4 13/16” Anderson casement picture window 400Ptr 4510 Quantity 6 along roof of porch 08550-05 1’8 ½” x 4’ 4 13/16” Anderson awning window 400an451 Quantity 6 along roof of porch 08870- Plastic Glazing 08870-01 5’- 4 1/2” x 8 7/8” Sidelight glazing Quantity 2 08870-02 3’-1 1/4” x 8 7/16” Transom glazing above front door Quantity 2
09 FINISHES
09250 - Gypsum Board 09250-01 Gold Bond® 8 ft. x 4 ft. x 5/8 in. Fire Shield Gypsum Board Can be purchased from Home Depot in East Liberty Assembled Depth (in.) : 96 in Assembled Height (in.) : .625 in Assembled Width (in.) : 48 in Item Weight : 70.46 lb Type x core for fire resistance Durable and easy to repair Easy to paint over, add texture to or wallpaper GREENGUARD Children & Schools Certified MFG Model # : GB99500800 MFG Part # : GB99500800
SP1.02
SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND
09051-Fasteners 09051-01 8 x 3/4 The Hillman Group Flat Phillips Wood Screws Item #: 57231 | Model #: 490012 09051-02 8 x 1/2 The Hillman Group Flat Phillips Wood Screws 09051-03 Stanley-National Hardware Double Wide Corner Brace Item #: 66938 | Model #: MP121BC 09051-04 Jamb clip flat Quantity 34 09051-05 Andersen auxiliary casing 09051-06 Andersen aluminum reinforced join Quantity 3 09051-07 Andersen exterior trim strip Quantity 3 09051-08 Andersen casing Quantity 3 09051- 09 1/4” X 1- 3/8” The Hillman Group Flat Head Sleeve Anchor 09051-10 5 x 1-1/2 The Hillman Group Flat Head Phillips Wood Screws
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
EXISTING SITE CONDITIONS 1
2
3
1. Large South-facing windows maximize sun exposure in winter months 1. Porch oriented for optimal solar access 2. Neighboring home blocks West / South-west winds in winter 3. Large roof area for rainwater catchment
+ ASSETS
4
5
4. Poor insulation causes high heat bills in winter 5. Building is shaded by neighboring home along Western facade 5. Roof of porch blocks sunlight in winter months
- LIABILITIES
+3 +3
+1
-5
+1
SITE CONTEXT: EXISTNG ASSESTS AND LIABILITIES
SC1.00
SUN STUDIES OF ADAPTIVE TRANSFORMATION
Using the available sun along the existing southwest porch our adaptive transformation allows sun to penetrate to the living area. By encasing the porch in glass the living space can be extended to the front of the home and can integrate the porch culture year round. Passive heating strategies can be utilized through the winter to lower heating costs and maxmize daylight. These series of sun studies show the sun and shading conditions through various months of the year at 9am, 12pm, and 3pm. In the winter months the living space can maximize the available sunlight and in the summer months the living space is shaded through the trellis structure and plantings.
SC1.01
SITE CONTEXT: SUN STUDIES
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
PROPOSAL: RAIN MANAGEMENT FRONT ROOF Rainwater shed: 10.720 gallons / year
BACK ROOF Rainwater shed: 13,080 gallons / year
22
?
15
11 F
T
FT
6S
16
T QF
15
? Total area of roof: 1,010 sq.ft. Pittsburgh annual rainfall: 37.86â&#x20AC;? TOTAL WATER COLLECTION 23,800 gallons / year 22 waterbottles x 20oz ea. = 440oz = 3.4 gallons
FT
The current situation and materials used on the site do not allow for effective rain water management. The concrete driveway and backyard make it impossible to manage rain water. Adding a rain garden in the backyard will minimize the water runoff during a storm and allows for better infiltration. Using a bottle rain gutter collector will allow the resident to collect water that can be used for upkeep fo the front garden.
SITE CONTEXT: GENERAL SITE MODIFICATIONS
SC1.02
RAIN GARGEN The rain garden will help to manage rainwater run off by increasing the amount of water that infiltrates into the ground on the lot. It will also serve to enhance the visual appeal of the immediate outdoor environment
downspout
BERN 10â&#x20AC;&#x2122; away from foundation
SOIL TEST It is important to know the soil type exists in the lot becasue different soil takes different amount of time to aborb water. The 3 types are sandy, silty or clayey: sandy soil has the fastest infiltration; clayey soil has the slowest.
Size of Rain Garden relative to roof area for different soil types Sand Silt Clay % of Roof Area
SC1.03
20%
SITE CONTEXT: GENERAL SITE MODIFICATIONS
30%
60%
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
RAIN GARDEN SIZE & PLACEMENT Determine the rain garden size base on the size of the drainage area. In doring so, residents will have to opproximate the size of their roof. We have situated the rain garden in the back of the house, since two third of the rain will be feeding the back downspout. And we have estimated that the roof area ia 666 sf. Requirements include that the garden must be placed at least ten feet from the foundation. The rain garden area is based on both the soil type and depth of the rain garden basin. The garden will be 3”-5” (required for silty soil as found ont he site). It will be placed fifteen feet back from the house and have a total area of 166 sq.ft.
BERN LOT SLOPE IS LESS THAN 4%, RAIN GARDEN NEEDS TO BE 3-5” DEEP
<30’ from downspout but 10’ away from foundation
SITE CONTEXT: GENERAL SITE MODIFICATIONS
SC1.04
PLANT TYPES Native planting types options for shaded conditions in western Pennsylvania include: Blue Eyed Grass, Marginal Wood Fern, Rosebay, Silky Dogwood, Bur Sedge and Virginia Wild Rye.
$
SC1.04
COST Creating a rain garden can potentially cost very minimally if the resident invite their friends and relatives to help the construction of it. It could ptentially be a fun bonding activitiy.
SITE CONTEXT: GENERAL SITE MODIFICATIONS
Construction Design Planting Plants Total Cost
$3 / sq. fit. $1 / sq. fit. $3-4 / sq. fit. $2.5 - 4.5 / sq. ft. $11-13 / sq. ft.
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
RAINDROPS SYSTEM The Raindrop gutter water bottle system is an affordable way to collect rainwater using standard water bottles. Bottles can be attached and detached as needed the UV rays from the run helps eliminate pathogenic microorganisms that cause disease, allowing the collected water to be used for washing hands and watering plants. There are two types of caps that can be interchangable, one to water plants or wash hands and the other to allow the bottle to be attached to the gutter system.
RAINWATER
UV PLASTIC WATER BOTTLE GUTTER
07715-01 RECYCLED PLASTIC WATER BOTTLE
CAP AND ATTACHMENT OPTIONS
SITE CONTEXT: GENERAL SITE MODIFICATIONS
SC1.05
SITE MODIFICATION
Selecitve excavaton of site for plaement of rain garden system
SD1.00
SELECTIVE DEMOLITION: DIAGRAMS
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
Shingle
Underlayment Sheathing
Joist Fascia
Exterior Brick Wall
Double Brick Wall
Facade
Exterior Brick Wall
PORCH MODIFICATION
Selective demolition of existing structure for insertion of proposed design
Steps
Concrete Pavement Exterior Brick Wall
SELECTIVE DEMOLITION: DIAGRAMS
SD1.01
ARC48_550
Pittsburgh Program for the Adaptive Transformation of Community Housing
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/ OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
ABBREVIATIONS:
SYMBOLS LEGEND:
C.L. - CENTER LINE O.C. - ON CENTER R.O. - ROUGH OPENING
KEYNOTE:
MATERIAL LEGEND: BRICK MASONRY
1
DOOR SCHEDULE: 01
KEYNOTE DESIGNATION
ELEVATION TAG:
02
1|AT1.01
SHEET NUMBER
DRAWING NUMBER
03
SECTION TAG: DIMENSIONAL LUMBER
CONCRETE
STEEL
1|AT1.01
SHEET NUMBER
01
DETAIL TAG: DRAWING NUMBER 1
02
AT3.01 CONCRETE/BRICK AGGREGATE
FINISH FLOOR ELEVATION:
F.F.E. 0’ - 0”
GYPSUM WALL BOARD
FIBERGLASS INSULATION
SHEET NUMBER
DOOR TAG:
01
WINDOW TYPE TAG:
01
PLASTER LATH
DESIGNATOR
08210-01 Architectural Rectangle Hinged Door H-400series 3' 1-5/8" W x 6' 10"
08550-01 Andersen casement window 400 series c255 5’-4 13/16” x 4’ 08550-02 Andersen casement window 400 series cw155 5’ -4 13/16” x 2’ -4 3/8”
03
08550-03 Anderson casement window 400 series cw145 4’- 4 13/16” x 2’ – 4 3/8”
04
08550-04 Anderson casement picture window 400 series Ptr 4510 1’ x 4’4 13/16” (x6)
05
08550-05 Anderson awning window 400 series an451 1’8 ½” x 4’ 4 13/16” (x6)
DESIGNATOR
RIGID FOAM INSULATION
08350-02 Anderson Outswing Folding Door-Two Panel 2R 3’-2 ¼” x 6’ 10”
WINDOW SCHEDULE:
DRAWING NUMBER
08350-01 Anderson Outswing Folding Door-Two Panel 2L 3’-2 ¼” x 6’ 10”
ADAPT TRANSFORMATION: INDEX
AT0.00
06110-14 06110-05 06110-03
01 01 02
01
01
02
03
01
02 06110-16 06110-21
1. SOUTHWEST PERSPECTIVE SCALE: NOT TO SCALE
AT1.00
ADAPT. TRANSFORMATION: EXTERIOR PERSPECTIVE
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
06110-14 06110-05 06110-01 03
01
03
03
1. SOUTHEAST PERSPECTIVE SCALE: NOT TO SCALE
ADAPT. TRANSFORMATION: EXTERIOR PERSPECTIVE
AT1.01
1|AT1.13
1|AT1.18
07210-01
02
01
01
02
01
09250-01
01
03
1|AT1.10
1|AT1.12
1|AT1.12
1|AT1.15
01
02
03
1|AT1.13
03
1. FIRST FLOOR PLAN SCALE: 1/4” = 1’-0”
AT1.02
ADAPT TRANSFORMATION: FIRST FLOOR PLAN
1|AT1.16
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/ OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1|AT1.10
ADAPT TRANSFORMATION: FIRST FLOOR PLAN
AT1.03
1|AT1.18
07210-01
1|AT1.15
1|AT1.10
1|AT1.16
1. SECOND FLOOR PLAN SCALE: 1/4” = 1’-0”
AT1.04
ADAPT TRANSFORMATION: SECOND FLOOR PLAN
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1|AT1.10
ADAPT TRANSFORMATION: SECOND FLOOR PLAN
AT1.05
1|AT1.13
1|AT1.18
06110-14 06110-1406110-05 06110-01 06110-11 06110-0506110-01 06110-11
O.C. O.C.
1|AT1.10
0202
0404
07210-01 07210-01 09250-01 09250-01
0101
0505
0101
0505
0202
0101
0101
0404
1|AT1.12
1|AT1.15
1|AT1.12
0404
0505
0505
0404
0404
0505
0505
0404
0303
1|AT1.13
0303
1. FIRST REFLECTED CEILING PLAN SCALE: 1/4” = 1’-0”
AT1.06
ADAPT TRANSFORMATION: FIRST REFLECTED CEILING PLAN
1|AT1.16
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1|AT1.10
ADAPT TRANSFORMATION: FIRST REFLECTED CEILING PLAN
AT1.07
1|AT1.13
1|AT1.18
1 AT3.00
1|AT1.10
1|AT1.15
1|AT1.12
SCALE: 1/2” = 1’-0”
AT1.08
ADAPT TRANSFORMATION: ENLARGED FIRST FLOOR PLAN
1 AT3.04
1|AT1.13
1. ENLARGED FIRST FLOOR PLAN 1|AT1.16
1 AT3.01
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1|AT1.10
1|AT1.12
1 AT3.03
ADAPT TRANSFORMATION: ENLARGED FIRST FLOOR PLAN
AT1.09
1 AT3.07
1|AT1.15
ATTIC LEVEL 19’ - 5 1/8”
SECOND FLOOR LEVEL 10’ - 0”
FIRST FLOOR LEVEL 0’ - 0”
BASEMENT LEVEL -10’ - 0”
1. BUILDING SECTION WEST SCALE: 1/8” = 1’-0”
AT1.10
ADAPT TRANSFORMATION: SECTION WEST
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
ADAPT TRANSFORMATION: SECTION WEST
AT1.11
1|AT1.13 1|AT1.13
1 AT3.04
1. ENLARGED SECTION WEST SCALE: 1/2” = 1’-0”
AT1.12
ADAPT TRANSFORMATION: ENLARGED SECTION WEST
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT.
1|AT1.10
4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1. ENLARGED CROSS SECTION SCALE: 1/4” = 1’-0”
1|AT1.17 1|AT1.10
1|AT1.12
1|AT1.19
1|AT1.12
1 AT3.08
ADAPT TRANSFORMATION: ENLARGED CROSS SECTION
AT1.13
1|AT1.10 ATTIC LEVEL 19’ - 5 1/8”
1|AT1.17
1|AT1.19
ATTIC LEVEL 19’ - 5 1/8”
SECOND FLOOR LEVEL 10’ - 0”
SECOND FLOOR LEVEL 10’ - 0”
03
FIRST FLOOR LEVEL 0’ - 0”
SCALE: 1/4” = 1’-0”
AT1.14
02
1 AT3.09
FIRST FLOOR LEVEL 0’ - 0”
1|AT1.10
1. SOUTH ELEVATION
01
ADAPT TRANSFORMATION: SOUTH ELEVATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
ADAPT TRANSFORMATION: SOUTH ELEVATION
AT1.15
1|AT1.15 1|AT1.13
03
03
1. EAST ELEVATION SCALE: 1/4” = 1’-0”
AT1.16
ADAPT TRANSFORMATION: EAST ELEVATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/ OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
ADAPT TRANSFORMATION: EAST ELEVATION
AT1.17
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/ OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1. WEST ELEVATION SCALE: 1/4” = 1’-0”
AT1.18
ADAPT TRANSFORMATION: WEST ELEVATION
ARC48_550
1|AT1.13
1|AT1.15
Pittsburgh Program for the Adaptive Transformation of Community Housing
01
01
02
01
01
02
ADAPT TRANSFORMATION: WEST ELEVATION
AT1.19
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/ OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
1. PERSPECTIVE SECTION SCALE: NOT TO SCALE
AT2.00
ADAPT TRANSFORMATION: PERSPECTIVE SECTION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ADAPT TRANSFORMATION: PERSPECTIVE SECTION
ARC48_550
AT2.01
1. AXONOMETRIC SECTION SCALE: NOT TO SCALE
AT2.02
ADAPT TRANSFORMATION: AXONOMETRIC SECTION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/ OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
ADAPT TRANSFORMATION: AXONOMETRIC SECTION
AT2.03
KEYNOTES 1. 2. 3. 4. 5. 6. 7. 8.
ALIGN 4”X4”X5’6” WOOD COLUMN TO THE ON TOP OF THE 2 1/2” BRICK WALL, FLUSH WITH THE EDGE OF THE WALL ALIGN 4“X4” WOOD COLUMN ON THE CORNER BETWEEN THE 4“X4”X5’6” WOOD AND 2“X6” WINDOW FRAME INSTAL THE CASING AND CAULK THE GAP BETWEEN THE EXTERIOR BRICK AND THE CASING FASTEN THE WINDOW FRAME WITH ‘JAMB CLIP FLAT’ AND SCREWS TO THE 2”X6” ALIGN 2”X6” NEXT TO THE 4”X4” COLUMNS AS A PART OF A WINDOW FRAME NOTCH-IN THE GLASS IN BETWEEN THE TWO 2”X4” WOOD MAKE 3/4” CUTS INTO 2”X4” WOOD AND INSTAL THEM NEXT TO WOOD COLUMNS PLACE 2”X4” NEXT TO THE SIDELIGHT FRAME AND FASTEN TO THE ENTRANCE DOOR FRAME
2 1
4 3
09051-05 07240-01 06110-03 06110-11
08550-02
06110-02 09051-04
09501-01
06110-23
5
08870-01 6 06110-23 06110-15
7 8 08210-01
1. SW CORNER DETAIL SCALE: 1 1/2” = 1’-0”
AT3.00
ADAPT TRANSFORMATION: PLAN DETAIL 1
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
KEYNOTES 1. 2. 3. 4. 5. 6.
PLACE A 2”X4” LUMBER SPACER NEXT TO THE EXISTING BRICK WALL PLACE THE INSULATION NEXT TO THE SPACER FASTEN THE WINDOW FRAME WITH ‘JAMB CLIP FLAT’ AND SCREWS TO THE 2”X6” INSTAL THE CASING AND CAULK THE GAP BETWEEN THE EXTERIOR BRICK AND THE CASING ENCLOSE THE INSULATION AND THE 2”X4” WOOD FRAME WITH DRYWALL INSTAL 4”X4” WOOD COLUMN NEXT TO THE BRICK WALL
4
4 3
6
5
2
1
3
08550-02
07210-01
06110-23
09250-01
06110-02
06110-11 09051-03
08550-01
09051-04 09051-03 06110-11 07240-01 09051-05
09051-04
1. NW CORNER DETAIL SCALE: 1 1/2” = 1’-0”
ADAPT TRANSFORMATION: PLAN DETAIL 2
AT3.01
KEYNOTES 1. PLACE A 2”X4” LUMBER SPACER NEXT TO THE EXISTING BRICK WALL 2. PLACE THE INSULATION NEXT TO THE SPACER 3. FASTEN THE WINDOW FRAME WITH ‘JAMB CLIP FLAT’ AND SCREWS TO THE 2”X6” 4. INSTAL THE CASING AND CAULK THE GAP BETWEEN THE EXTERIOR BRICK AND THE CASING 5. ENCLOSE THE INSULATION AND THE 2”X4” WOOD FRAME WITH DRYWALL 6. ALIGN 4”X4” AND 2”X4” WOOD COLUMNS NEXT TO THE BRICK WALL 7. CHEW GUM FOR AT LEAST 2MINUTES USING YOUR JAW. SPIT OUT THE GUM AND MOLD IT INTO AN ELLIPSE. THEN PLACE IT BETWEEN THE DOOR FRAME AND THE 4”X4” WOOD FRAME. APPLY PRESSURE ON THE FRAME AGAINST THE 4”X4” COLUMN.
5
3 4
08550-03
ADAPT TRANSFORMATION: PLAN DETAIL 3
1
09051-04 09051-01 09051-05
AT3.02
2
07240-01
SCALE: 1 1/2” = 1’-0”
09250-01
1. NE CORNER DETAIL
07210-01
6
06110-15
06110-01 08350-02 06110-15 7
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
KEYNOTES 1. 2. 3. 4. 5. 6.
PLACE A 2”X4” LUMBER SPACER NEXT TO THE EXISTING BRICK WALL PLACE THE INSULATION NEXT TO THE SPACER FASTEN THE WINDOW FRAME WITH ‘JAMB CLIP FLAT’ AND SCREWS TO THE 2”X6” INSTAL THE CASING AND CAULK THE GAP BETWEEN THE EXTERIOR BRICK AND THE CASING ENCLOSE THE INSULATION AND THE 2”X4” WOOD FRAME WITH DRYWALL ALIGN 4”X4” WOOD COLUMN NEXT TO THE BRICK WALL
1
07210-01
6
06110-23
5
09250-01
06110-01
07240-01
09251-08 09250-13
3
09251-01
09051-04
08550-03
4
2
1. SE CORNER DETAIL SCALE: 1 1/2” = 1’-0”
ADAPT TRANSFORMATION: PLAN DETAIL 4
AT3.03
5
KEYNOTES
06110-14
1. SET BRICK AGGREGATE CONCRETE ACCORDING TO CONSTRUCTED FORMWORK 2. ERECT 4” X 4” COLUMN AND BEAM WOOD FRAMING. 3. CONSTRUCT PORCH OVERHEAD WOOD FRAMING SYSTEM WITH 2” X 12” LUMBER RAFTERS AND 2” X 6” LUMBER BEAMS. INSTALL ABOVE ERECTED COLUMN AND BEAM PORCH SYSTEM. 4. CONSTRUCT WINDOW FRAMING SYSTEM AND INSTALL SPECIFIED PICTURE WINDOW AND AWNING WINDOW SYSTEMS (SEE WINDOW SCHEDULE FOR REFERENCE). SET IN PLACE WITHIN OVERHEAD WOOD FRAMING SYSTEM. 5. ATTACH 2” X 4” TRELLIS SYSTEM NOTCHED ABOVE OVERHEAD FRAMING SYSTEM. 6. ASSEMBLE DOOR FRAMING SYSTEM AND INSTALL SPECIFIED HINGED DOOR AND FOLDING DOORS (SEE DOOR SCHEDULE FOR REFERENCE) 7. ASSEMBLE TRANSOM GLAZING SYSTEM. INSTALL ABOVE HINGED DOOR SYSTEM 8. ASSEMBLE AND INSTALL RAILING SYSTEM ACCORDING TO (REPLACE WITH AT.SHEET-REFERENCE)
06110-05
3
06110-09 4
08550-04 06110-04
2
06110-03
08870-02
7
08210-01 6
8
1. DOOR SECTION DETAIL SCALE: 1 1/2” = 1’-0”
AT3.04
ADAPT TRANSFORMATION: SECTION DETAIL 1
1
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
KEYNOTES 1. REPLACE TEMPORARY SHORING SYSTEM WITH STEEL LINTELS TO SUPPORT THE REMAINING FACADE AFTER COMPLETION OF DEMOLITION. 2. INSTALL 2” POLYURETHANE RIGID FOAM INSULATION OVER EXISTING PLASTER LATH AND WOOD FURRING FINISH TO REDUCE HEAT LOSS AND PROVIDE MOISTURE CONTROL. 3. INSTALL 5/8” GYPSUM PLASTERBOARD FINISH OVER INSULATION. APPLY PAINT, PRIMER AND ONE-COAT. 4. ATTACH QUARTER ROUND MOLDINGS ALONG WALL TO FLOOR SEAM TO FINISH. 5. ERECT 4” X 4” COLUMN AND BEAM WOOD FRAMING. 6. CONSTRUCT PORCH OVERHEAD WOOD FRAMING SYSTEM WITH 2” X 12” LUMBER RAFTERS AND 2” X 6” LUMBER BEAMS. INSTALL ABOVE ERECTED COLUMN AND BEAM PORCH SYSTEM. 7. CONSTRUCT WINDOW FRAMING SYSTEM AND INSTALL SPECIFIED PICTURE WINDOW AND AWNING WINDOW SYSTEMS (SEE WINDOW SCHEDULE FOR REFERENCE). SET IN PLACE WITHIN OVERHEAD WOOD FRAMING SYSTEM. 8. ATTACH 2” X 4” TRELLIS SYSTEM NOTCHED ABOVE OVERHEAD FRAMING SYSTEM.
3 4
09250-01 07210-01
8
06110-14 06110-05 08550-04
7
6
08550-05 06110-09 06110-04 06110-03 06110-02 05120-01
5 1
2
1. ROOF SECTION DETAIL
SCALE: 1 1/2” = 1’-0”
ADAPT TRANSFORMATION: SECTION DETAIL 2
AT3.05
KEYNOTES 1 NEW 4” CONCRETE AND BRICK AGGREGATE 2 PLACE 2” RIGID INSULATION ALONG BRICK 3 ALIGN 5.8” GYPSUM BOARD WITH INSULATION 4 PLACE 2” X 6” WOOD FRAME 5 INSERT ANDERSEN AUXILIARY CASING AND CAULK 6 INSERT ANDERSEN WINDOW 7 PLACE LINTEL ABOVE WINDOW TO SUPPORT EXISTING BRICK
07210-01 7
05120-01 09051-05 06110-12
6
03
5 4
07240-01 06110-12 09250-01
3
2
1
1. WALL SECTION DETAIL SCALE: 1 1/2” = 1’-0”
AT3.06
ADAPT TRANSFORMATION: SECTION DETAIL 3
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
KEYNOTES 1. INSTALL 2” POLYURETHANE RIGID FOAM INSULATION OVER EXISTING PLASTER LATH AND WOOD FURRING FINISH TO REDUCE HEAT LOSS AND PROVIDE MOISTURE CONTROL. 2. INSTALL 5/8” GYPSUM PLASTERBOARD FINISH OVER INSULATION. APPLY PAINT, PRIMER AND ONE-COAT. 3. REMOVE EXISTING FLOOR FINISH FROM ATTIC FLOOR SYSTEM AND INSTALL 12” R-38 HIGH DENSITY FIBERGLASS BLANKET INSULATION IN BETWEEN THE SECOND FLOOR AND THE ATTIC TO REDUCE HEAT LOSS. PLACE INSULATION IN BETWEEN THE EXISTING FLOOR JOISTS . 4. RECOVER ATTIC FLOOR WITH PLYWOOD SHEATHING. 5. INSTALL LEAFGAURD SEAMLESS GUTTER SYSTEM ALONG THE EXISTING ROOF.
5 07715-01
4
3 07210-02
07210-01 09250-01 2
1
1. GUTTER SECTION DETAIL ADAPT TRANSFORMATION: SECTION DETAIL 4
AT3.07
KEYNOTES 1. FASTEN THE 2”X12” AND 4”X4” WITH A METAL BRACE AND SCREWS 2. MAKE A CUT ON THE TRELLIS WOOD BY THE DEPTH OF 3/4” AND NOTCH IN THE 2”X12” WOOD 3. REST THE TRELLIS ON THE BRICK WALL 4. FASTEN THE SCREW THROUGH THE METAL BRACE AND THE BRICK 5. FASTEN THE SCREW THROUGH THE METAL BRACE AND THE WOOD TRELLIS
1
2
3
4
5
06110-03 09051-03 09051-01 06110-05 06110-06
06110-03 06110-04 06110-01
1. ROOF SECTION DETAIL SCALE: 1 1/2” = 1’-0”
AT3.08
ADAPT TRANSFORMATION: SECTION DETAIL 5
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
GENERAL NOTES: 1. THESE DOCUMENTS ARE THE COPY RIGHTED PROPERTY AND INTELLECTUAL PROPERTY OF THE CARNEGIE MELLON UNIVERSITY/PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING. THE DOCUMENTS ARE NOT TO BE REPRODUCED OR UTILIZED FOR ANY PURPOSE OTHER THAN ORIGINALLY INTENDED AS STIPULATED ON SHEET IN 1.02 AND GOVERNS ALL SHEETS INCLUDED IN THE INDEX IN1.00 - IN1.01. USE OF THE DOCUMENTS FOR ANY PURPOSE, SPECIFICALLY STIPULATED OR NOT, SHALL BE GRANTED ONLY VIA AUTHORIZED WRITING PRODUCED ON CARNEGIE MELLON UNIVERSITY/ PITTSBURGH PROGRAM FOR THE ADAPTIVE TRANSFORMATION OF COMMUNITY HOUSING INITIATIVE LETTERHEAD. 2. NONE OF THE DOCUMENTS INCLUDED IN DRAWING INDEX ARE INTENDED TO BE CONSIDERED IN ISOLATION OF ONE ANOTHER. ALL PARTIES/ENTITIES UTILIZING THESE DOCUMENTS FOR BIDDING, QUANTITY SURVEY, AND/OR CONSTRUCTION SHALL CONSULT THE GENERAL NOTES AND INFORMATION LOCATED ON THIS SHEET AND ALL “SP” SERIES (SPECIFICATIONS: CSI DESIGNATED MATERIAL ANNOTATION LEGEND) AND “CA” SERIES (GOVERNING CODE ANALYSIS FOR ADAPTIVE TRANSFORMATION) SHEETS FOR INFORMATION AND CONDITIONS GOVERNING WORK DESCRIBED IN DOCUMENTS LISTED IN THE DRAWING INDEX BEFORE PROCEEDING WITH PROCUREMENT AND/OR CONSTRUCTION. GENERAL INFORMATION AND DATA SHEET(S) (“G”) PROVIDE CODE PROCEDURAL AND USE GUIDELINES GOVERNING ALL BID AND/OR CONSTRUCTION DOCUMENTS. ALL BIDDERS, SUB-BIDDERS, CONTRACTORS, AND SUB-CONTRACTORS SHALL UTILIZE COMPLETE SETS OF THE BIDDING AND/OR CONSTRUCTION DOCUMENTS IN QUANTIFYING AND CONSTRUCTING. NEITHER THE OWNER NOR ARCHITECT ASSUMES RESPONSIBILITY FOR ERRORS, OMISSIONS, OR MISINTERPRETATIONS RESULTING FROM THE USE OF INCOMPLETE SETS OF BIDDING AND/OR CONSTRUCTION DOCUMENTS. 3. DO NOT SCALE DRAWINGS OR UTILIZE SCALED DIMENSIONS. USE ONLY DIMENSIONS/DIMENSIONAL INFORMATION PROVIDED IN THE DOCUMENTS. WHEN NO DIMENSIONAL INFORMATION IS PROVIDED, BIDDER, SUB-BIDDER, CONTRACTOR, AND SUBCONTRACTOR SHALL CONSULT WITH THE ARCHITECT IN WRITING. ENTITIES UTILIZING DOCUMENTS SHALL NOT EXECUTE RELEVANT WORK UNTIL WRITTEN RESPONSE/ DIRECTIVE HAS BEEN PROVIDED BY ARCHITECT. 4. ALL CONSTRUCTION MATERIALS AND INSTALLATIONS SHALL CONFORM TO THE INTERNATIONAL RESIDENTIAL CODE 2009 AS WELL AS ALL APPLICABLE FEDERAL CODES, STATE CODES, LOCAL CODES, TRADE ASSOCIATION STANDARDS, AND/OR MANUFACTURERS STANDARDS AS ADOPTED BY THE CITY OF PITTSBURGH.
KEYNOTES
9 07715-01
1 NEW 4” CONCRETE AND BRICK AGGREGATE 2 PLACE PIN IN CONCRETE FLOOR AND ATTACH WOOD POST 3 DRILL HOLE TO PLACE 2“ X 4” WOOD RAILING, CAP RAILING AND PLACE WITHIN BRICK 4 ALIGN PLATE TO WOOD AND BRICK AND ATTACH WITH PLATE AND CONCRETE ANCHOR 5 FASTEN WOOD RAIL TO POST THRU PLATE 6 ATTACH .5” WOOD RAIL AT NOTCHED POINTS IN WOOD SUPPORT RAIL 7 ATTACH 2” X 4” WOOD HAND RAIL TO NOTCHED SUPPORT RAILS 8 ALIGN PLATE TO WOOD AND SCREW IN PLACE 9 ALIGN GUTTER TO EXTERIOR BRICK WALL 10 ATTACH GUTTER TO BRICK WITH METAL CHANNEL 11 ATTACH WATER BOTTLE TO GUTTER
7
07715-02 07715-03 10 3
11 06110-16 09051-10
8
06110-21
06110-22
5
6
4
09051-03 09051-09 06110-17
3
09051-02
2 1
1. RAIL SECTION DETAIL
SCALE: 1 1/2” = 1’-0”
ADAPT TRANSFORMATION: SECTION DETAIL 6
AT3.09
OPEN AND CLOSED CONDITION
AIRTIGHT SEALANT FLASHING CAP CUSTOMIZED CURVED GLASSS
DESSICANT FLASHING CAP WINDOW COMPONENT
AT3.10
ADAPT TRANSFORMATION: WINDOW DIAGRAM
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
1. STATE AFTER DEMOLITION
2. SHORING & LINTEL
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
AS1.00
3. AGGREGATE CONCRETE (THERMAL MASS)
4. CONCRETE STEPS AND PLANTERS
AS1.01
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
5. BRICK MASONRY WALLS
6. 4”X4” LUMBER
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
AS1.02
7. 4”X4” LUMBER BEAMS
8. 2”X12” LUMBER
AS1.03
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
9. 2”X4” LUMBER & WINDOWS
10.2”X4” LUMBER
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
AS1.04
11. 2” POLYURETHANE RIGID INSULATION
12. 2”X4” AND 1/2”X1/2” LUMBER
AS1.05
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
13. GRASS
ASSEMBLY SEQUENCE: PICTORAL DEPICTION OF STAGED IMPLIMENTATION
AS1.06
N
sidew
alk
N
sidew
N
sidew
alk
alk
N
sidew
alk
N
sidew
alk
NORTH-SOUTH ORIENTATION
Row houses oriented along the North-South orientation can take advantage of the southern exposure for passive solar heating gains and sunlight. Depending on the orientation and location of the home, the extension of the living space can be situated along the South. this would either be in front of the house or the back, depending on the orientation. the glass extension can be manipulated in terms of depth according to the site setbacks and condition of the buildings. The two lareger digrams depict the glass living space along the south side, situated either in the front or the back of the house. The depth of extension would depend on the existing lot room. The glass can either be placed within a corner of the house, extended only a portion, or taken to the full extension that was originally designed for the main home. The smaller three diagrams show the glass extension placed in the back of the house along the south in both conditions of an existing row house and extension. Another alternative woud be to place the extension flush along a front southern facade.
OM1.00
ADAPTIVE TRANSFORMATION ORIENTATION MODIFICATION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
sidew alk
ot nt l
a vac
ditio
con
n
sidew alk
sidew alk
vac
co lot ant
tion ndi
sidew alk
sidew alk
N
EAST - WEST ORIENTATION
Houses oriented along the East-West orientation can utilize the long south facade (if provided with access to sun or a vacant lot) to extend the living space outwards and gain passive solar heating. In situations where homes are attatched, the design can be modified to be placed on either the east or west facade. The two large diagrams depict the utilization of the south facade depending on the presence of a vacant lot. The glass can either be flush or extend outwards depending on the lot condition. If a vacant lot is not present, the deisgn can be relocated to the West side. The three small diagrams are iterations depicting other placements of the extension. The facade can be oriented along the west depending on available sunlight.
ADAPTIVE TRANSFORMATION ORIENTATION MODIFICATION
OM1.01
PITTSBURGH PARTY WALL PROGRAM
POSSIBLE FUNDING SOURCES
Grant: $10,000 To rehabilitate exposed party walls Documents Needed: -Two (2) most recent pay stubs and/or copies of your Social Security and pension verification for all members of the household. -A copy of your 2008 Federal Income Tax Return or 2008 Property Tax/Rent Rebate Form. If you do not file a tax return or rebate form, please call 1-800-829-1040 and request a “Form 1722” letter. - A full copy of your deed.
$10,000 GRANT
Send the Application and Documents to: URA of Pittsburgh 200 Ross Street Pittsburgh, PA 15219 Attn: Sharon Taylor http://www.ura.org/pittsburgh_residents/factsheets/PPWP-OwnerApplication.pdf
PITTSBURGH HOME REHABILITATION PROGRAM (PHRP) & PHRP PLUS FOR ENERGY EFFICIENCY Loan : Home Improvement $25,000 0% interest rate up to 20 years
$25,000 LOAN
Grants: Energy Efficiency and Home Improvement PHRP PLUS : $2,100 (energy efficiency) PHRP: $2,000 - $2,500(exterior) http://www.ura.org/pittsburgh_residents/factsheets/PHRP.pdf
HOME DEPOT GRANT Community revitalization project to create healthy and sustainable homes The LEED for Homes Initative for Affordable Housing collaborated with The Home Depot Foundations for this grant to promote green affordable housing.
$2,000- $2,500 GRANT
http://www.homedepotfoundation.org/
ENERGY POLICY ACT 2005 Tax Incentive program Up to $500 Tax Credit for energy efficient appliances, windows and insulation
IMP1.00
IMPLEMENTATION DOCUMENTATION: LOGISTICS
$500
TAX CREDIT
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
HOPE VI REVITALIZATION GRANT Grant funds provided to a community organization or public housing authority to revitalize existing housing and relocate public housing residents into mixed income communities. The Middle-Income Homeownership Program provides funding for homeowners and potential homeowners at less than 100% of the area median income for a 4-person family. These funds can be used to repair of add-on to existing homes or to demolish and construct new ones. The goal of this program is to improve the condition of existing housing stock in the community and provide assistance for residents to move out of public housing and into more mixed-income areas. Through Middle-Income Homeownership Program, Hope VI funds may be used to cover costs of the following: -downpayments and closing costs -provision of subordinate mortgages -construction financing for rehabilitation costs -demolition, abatement of hazardous materials, owner relocation, homeownership counseling, site improvements, administration, marketing, and legal costs related to constrcution and rehabilition. Applicable houses and market values: -119 41st Street: $34,400 -124 42nd Street: $83,400 -109 42nd Street: $24,800 -111 42nd Street: $18,600 -113 42nd Street: $22,700 -138 44th Street: $20,500 -150 44th Street: $31,600 -133 45th Street: $48,200 -143 45th Street: $35,800 -168 46th Street: $66,100 -133 46th Street: $38,100 -175 46th Street: $53,100 -306 45th Street: $23,900 -272 46th Street: $37,700 -302 46th Street: $30,000 -4627 Bancroft Street: $31,900 Send the Application and Documents to: Apply through Grants.gov website. http://www.hud.gov/offices/pih/programs/ph/hope6/grants/revitalization/revgrantmonitoring.pdf
IMPLEMENTATION DOCUMENTATION: LOGISTICS
IMP1.01
1
APPLY
BUILDING PERMITS
1. ZONING COUNTER 2. FILE ROOM 3. ENGINEER’S COUNTER 4. LICENSE & CASHIER COUNTER 1. LAND OPERATION PERMIT 2. DEPARTMENT OF CITY PLANNING 3. DEPARTMENT OF PUBLIC WORKS 4. PITTSBURGH WATER AND SEWER AUTHORITY 5. BBI 6. LICENSE & CASHIER COUNTER
2
APPLY
3
ACQUIRE
SEE CSI SPECIFICATIONS
4
RELOCATE
TO 4625 BANCROFT STREET
5
EXTENSION
SEE ADAPTIVE TRANSFORMATION DOCUMENTS SEE CRITICAL PATH
6
INSULATE
SEE ADAPTIVE TRANSFORMATION DOCUMENTS SEE CRITICAL PATH
MANAGE
SEE SITE CONTEXT DOCUMENTS
GRANTS AND LOANS
SEE GRANT INFORMATION PAGE HOPE 6 PITTSBURGH PARTY WALL PROGRAM PITTSBURGH HOME REHABILITATION PROGRAM & PHRP PLUS FOR ENERGY EFFICIENCY HOME DEPOT GRANT ENERGY POLICY ACT 2005
MATERIALS FOR CONSTRUCTION
RESIDENT STAYS AT NEIGHBOR
CONSTRUCTION NEW PORCH
+
7 8 IMP1.02
PLACE IN WALL INSULATION
ADD RAIN GARDEN FOR WATER MANAGEMENT
INSPECT
FINAL INSPECTION IMPLEMENTATION DOCUMENTATION: LOGISTICS
1. FOOT INSPECTION 2. ROUGH-IN INSPECTIONS 3. A FINAL INSPECTION
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
BUILDING PERMIT
1) ZONING COUNTER: Turn in application made by a contractor licensed by the City of Pittsburgh. Approval required for new construction/additions. An applicant must provide a survey or a plot plan (a hand drawn plan of the property ). Plan must indicated structures in relation to property lines and to the street(s). $25 Zoning Processing Fee 2) FILE ROOM: Clerk will check for outstanding code violation notices. 3) ENGINEER’S COUNTER: Review of plan- 15 working days. 4) LICENSE & CASHIER COUNTER: Pay by check or money order to cashier.
WHAT TO BRING WITH YOU:
Correct address of the job site. Owner’s name, address, and phone number. Residential Building Permit Application A check or money order to pay for the permit. Any required construction plans signed and sealed by a professional (engineer or architect) registered with the Commonwealth of Pennsylvania. The Fee
LAND OPERATION PERMITS ALL LAND
1)Obtain a Land Operations Permit Application(http://www.city.pittsburgh.pa.us/BBI/html/land_operation_permit.html#is_required). The application signature must be witnessed by a notary. 2) Take application to Department of City Planning- 200 Ross Street, 3rd Floor for review, approval and signature. 3) Take application fo Department of Public Works at 414 Grant Street, room 301. 4) Take application to Pittsburgh Water and Sewer Authority at 1200 Penn Avenue, Penn-Liberty Plaza 1. 4)Take application to BBI for final review and authorized signature. BBI will contact applicant when permit has been approved. 5)License & Cashier’s counter where check or money order is made.
WHAT TO BRING WITH YOU:
Initial submission: Completed Land Operations Checklist and Application, Plot Plan, Plot Plan Requirements, Identification of site involved,Official street address, Property dimensions, Lot and Block Number, Plan shall show existing and proposed buildings and other structures and adjacent streets and public or private property, Plans or statements clearly describing the nature and extent of the operations, General plan of work, cross sections, contours, soil & rock strata description, coal workings, locations of utilities, details of surface protection, details of walls or other structures on property. Plan showing preparation of natural ground surface by benching and removal of top soil, vegetation and other materials, Description of surface and subsurface draining control, Results of stability and analysis, Description of kind of material to be used in fill, Statement of intended moisture density control of fill, Statement of method of compacting fill and thickness of layers to be used in such compacting, Statement of tests to be made prior to and during the process of filling and the names of persons or agencies responsible for making the tests, Special Inspector Forms, Special Inspector Requirements Special Inspector Initial Report, Insurance certificate for work, Performance Bond , A check or money order to pay for the permit. Excavation,fill: (up to 1000 cubic yards) each permit $78.00
INSPECTION
It is the responsibility of the permit holder to arrange for all required inspections by contacting the appropriate inspector. The inspector’s name and phone number may be found in bold print on the permit. Required inspections include: 1)Footer inspection - after trenches or ditches are evacuated, forms and reinforcement are in place and before footer is poured or constructed. 2)Rough-in inspections - after the completion and prior to the concealment of framing, fire blocking, and any other building component. 3) A final inspection when all work is complete. measured from the bottom of the footing to the top of the wall, unless supporting a surcharge.
IMPLEMENTATION DOCUMENTATION: LOGISTICS
IMP1.03
IMP2.00
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
Pittsburgh Program for the Adaptive Transformation of Community Housing
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
ARC48_550
IMP2.01
PROJECT DESIGN
WEEK 1 IDENTIFY HOUSING TYPOLOGY & LOCATIONS IDENTIFY LAND USE & ZONING REQUIREMENTS FOR REGION CATALOG SITE UTILIZATION IDENTIFY DEVIATIONS FROM CODE STIPULATIONS CATALOG HOUSING CONDITIONS IDENTIFY MATERIAL & CONSTRUCTION TYPES IDENTIFY HEATING & COOLING METHODS ANALYZE DEMOGRAPHIC & ENVIRONMENTAL DATA IDENTIFY TYPOLOGY CASE STUDY BUILDING CODE ANALYSIS IDENTIFY WATER MANAGEMENT & ENCLOSURE MODIFICATIONS GRAPHIC REPRESENTATION OF ADAPTIVE TRANSFORMATION ORIENTATION MODIFICATION PROGRESSIVE IMPLEMENTATION & UNIT COST ESTIMATE
IMP2.02
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
10%
PROJECT SCOPE WEEK 2
WEEK 3
WEEK 4
WEEK 5
WE
K5
Pittsburgh Program for the Adaptive Transformation of Community Housing
35% WEEK 6
WEEK 7
65% WEEK 8
WEEK 9
WEEK 10
WEEK 11
ARC48_550
BENCHMARK WEEK 12
WEEK 13
WEEK 14
WEEK 15
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
IMP2.03
SYSTEMS MODIFICATION WEEK 1
WEEK 2
WEEK 3
WEEK 4
REMOVE EXISTING PORCH, SALVAGE BRICKS SET UP SHORING SYSTEM REMOVE BOTTOM PORTION OF SOUTHWEST WALL, SALVAGE BRICKS
WEEK
ASSEMBLE LINTEL SYSTEM BENEATH REMAINING MASONRY WALL DISASSEMBLE AND REMOVE SHORING ASSEMBLE AND INSTALL WOOD FRAMING MEMBERS ASSEMBLE AND INSTALL RAILING SYSTEM CREATE BRICK AGGREGATE CONCRETE MIXTURE PREPARE CONCRETE FORMWORK FOR THERMAL MASS FLOOR SYSTEM
W K
PREPARE CONCRETE FORMWORK FOR PLANTER POUR CONCRETE INTO FRAMEWORK, LET SET
W K
REMOVE FRAMEWORK INSTALL WINDOW AND DOOR SYSTEMS ASSEMBLE TRELLIS SYSTEM FILL PLANTER WITH SOIL AND PLANT DESIRED VEGETATION BREAK DOWN CONCRETE DRIVEWAY PREPARE GROUND, SMOOTH SOIL PLANT GRASS ON SITE STAKE OUT PERIMETER OF PROPOSED RAIN GARDEN EXCAVATE SOIL TO ACHIEVE SPECIFIED DIMENSIONS (SC1.05 ) LEVEL THE RAIN GARDEN AND SMOOTH OUT THE SOIL CREATE A SMOOTH, COMPACT BERM WITH DISPLACED SOIL FOLLOW PREVENTATIVE MEASURES FOR EROSION CONTROL ON BERM PLANT RECOMMENDED VEGETATION ACCORDING TO PLANNED LAYOUT MULCH AND WATER PLANTS TWICE A WEEK UNTIL PLUGS ESTABLISH REMOVE EXISTING GUTTER SYSTEM INSTALL LEAFGUARD SEAMLESS GUTTER SYSTEM ON ROOF AND PORCH ASSEMBLE AND ATTACH WATER COLLECTION SYSTEM TO GUTTER REMOVE DEMOLITION WASTE FROM SITE
IMP2.04
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
W K
WEEK 5
WEE
K 5
Pittsburgh Program for the Adaptive Transformation of Community Housing
WEEK 6
WEEK 7
WEEK
ARC48_550
WEEK
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
IMP2.05
MODIFICATION MODIFICATION MODIFICATION SHORING AND UNDERPINNING SHORING AND UNDERPINNING SHORING AND UNDERPINNING MASONRY MASONRY MASONRY
CSI No. CSI No. CSI No.
FASTENERS FASTENERS FASTENERS
HARD COST ($) HARD COST ($)
SYSTEM
UNIT QUANTITY
COST PER UNITY ($ / UNIT)
HARD COST ($)
Shoring for brick facade Shoring for brick facade
2250-01
Shoring for brick facade
4060 4060 4080 4080 4081 4060 4081 4080
Masonry Mortar [Quikrete 110210 Mortar Mix For Masonry (Pack of 6)] Mortar [Quikrete 110210 Mortar Mix For Masonry (Pack of 6)] Masonry Anchorage and Reinforcement and Reinforcement Masonry Anchorage Mortar [Quikrete 110210 Mortar Mix For Masonry (Pack of 6)] Masonry Anchorage and Reinforcement Quikrete Masonry Concrete Anchorage Quikrete Concrete Masonry Anchorage
1 1
17.34 17.34
1 9.28 9.28
17.34 94.5 94.5
Quikrete Concrete
9.28
94.5
$0.00 $0.00 $0.00
2
06110-01 4" x 4" 06110-01 4" 2" x 4" 12" 12" 06110-01 2" 4" x 6" 4"
98.7 98.7 69 69 182.5 98.7 182.5 348.5 69 348.5 68 182.5 68 348.5
6" 2" x 4" 12" 2" 4" .5 xxx .5 2" 6" .5 xx .5 2" 4"
$114.49 $114.49 $95.91 $95.91 $109.50 $114.49 $109.50 $94.10 $95.91 $94.10 $1.36 $109.50 $1.36 $94.10
68
0.02
$1.36
2282 2282 1320 1320 2282
$1,996.75 $1,996.75 $1,320.00 $1,320.00 $1,996.75
12" R-38 high Density fiberglass blacket insulation
1320
0.875 0.875 1 1 0.875 1
1 1 1 5 1 5 22 1 22 5
24.82 24.82 2.97 2.97 72 24.82 72 2.97 72
$24.82 $24.82 $2.97 $2.97 $360.00 $24.82 $360.00 $0.00 $2.97 $0.00 $360.00 $0.00 $0.00
1 1 2 2 1 2 2 2 6 2 6 2 6 6 6
1594 1594 3216 3216 391 1594 391 3216 391 391 465 391 465 422 391 422 465 422
$1,594.00 $1,594.00 $6,432.00 $6,432.00 $782.00 $1,594.00 $782.00 $6,432.00 $782.00 $782.00 $2,790.00 $782.00 $2,790.00 $2,532.00 $782.00 $2,532.00 $2,790.00 $2,532.00
12 12
$1,026.00 $1,026.00
DAP ALEX 10.1oz Painter's All-Purpose Acrylic Latex Caulk (12-pack) DAP ALEX 10.1oz Painter's All-Purpose Acrylic Latex Caulk (12-pack) Workforce Dripless 9in. Caulk Gun Workforce Dripless 9in. Caulk Gun Leaf Guard Seamless Gutter DAP ALEX 10.1oz Painter's All-Purpose Acrylic Latex Caulk (12-pack) Leaf Guard Seamless Gutter Water bottle rainwater collector Workforce Dripless 9in. Caulk Gun Water bottle rainwater collector Metal channel clip to Gutter attach gutter to brick Leaf Guard Seamless Metal channel clip to attach gutter to brick Water bottle rainwater collector
07715-01 07240-01 07715-01 07715-02 07715-02 07715-03 07715-01 07715-03 07715-02 07715-03 Metal channel clip to attach gutter to brick
22
$1,320.00
$0.00
08210-01 08210-01 08350-01 08350-01 08550-01 08210-01 08550-01 08550-02 08350-01 08550-02 08550-03 08550-01 08550-03 08550-04 08550-02 08550-04 08550-05 08550-03 08550-05 08550-04 08550-05
Architectural Rectangle Hinged Door H-400 Architectural Rectangle Hinged Door Andersen Outswing Folding Door TwoH-400 Panel Andersen Outswing Folding Door TwoH-400 Panel casement window 400Door c255 Architectural Rectangle Hinged Andersen Outswing c255 casement Folding windowDoor 400 cw155 Andersen Two Panel cw155 Andersen casement window 400 cw145 c255 window 400 Andersen casement picture 400 windowwindow 400 cw145 cw155 Andersen picture window 400 awning window 400 an451 Andersen casement casement window 400 cw145 Andersen casement awning window an451400 Andersen picture400 window
8870 8870
Glazing Glazing
85.5 85.5
8870
Glazing
85.5
12
$1,026.00
0.25 0.25 0.1 0.1 0.25
3602 3602 3602 3602 3602
$900.50 $900.50 $360.20 $360.20 $900.50 $360.20
0.0994 0.0994 0.0994 0.66 0.0994 0.66 0.0994
$49.70 $49.70 $24.85 $24.85 $21.12 $49.70 $21.12 $0.00 $24.85 $0.00 $21.12 $0.00 $0.00 $0.00 $0.00 $0.00 $72.00 $0.00 $72.00 $2.65 $0.00 $2.65 $72.00
Andersen awning window 400 an451
09250-01 Gypsum board 09250-01 Gypsum Paint board 09250-01 Paint Gypsum board 09051-01 09051-01 09051-02 09051-02 09051-03 09051-01 09051-03 09051-04 09051-02 09051-04 09051-05 09051-03 09051-05 09051-06 09051-04 09051-06 09051-07 09051-05 09051-07 09051-08 09051-06 09051-08 09051-09 09051-07 09051-09 09051-10 09051-08 09051-10 09051-09 09051-10
Paint
0.1
3/4 The Hilman Group Flat Philips Wood Screws 3/4 The Hilman Group Flat Philips Wood Screws 1/2 1/2 Flat Stanley-National Hardware DoubleWood Wide Screws Corner Brace 3/4 The The Hilman Hilman Group Group Flat Philips Philips Wood Screws Stanley-National Hardware DoubleWood Wide Screws Corner Brace Jamb clipHilman flat Group 1/2 The Flat Philips Jamb clip flat Andersen auxiliary casing Double Wide Corner Brace Stanley-National Hardware auxiliary casing Andersen aluminum reinforced join Jamb clip flat Andersen reinforced join exterior strip Andersen aluminum auxiliarytrim casing exterior strip Andersen aluminum casing trim reinforced join Andersen casing The Hillman Grouptrim flat head Andersen exterior strip sleeve anchor The Hillman Group flat head 1-1/2" Thecasing Hillman Group flatsleeve head anchor phillips wood screws Andersen 1-1/2" The Hillman Group flatsleeve head anchor phillips wood screws The Hillman Group flat head
500 500 250 250 32 500 32 34 250 34 32
8 8 40 40 8 1-1/2" The Hillman Group flat head phillips wood screws 40 TOTAL COST ($) TOTAL COST ($) CONTINGENCY CONTINGENCY ADJUSTED TOTAL TOTAL COST ($) TOTAL ($) PITTSBURGHADJUSTED LOCATION FACTOR CONTINGENCY PITTSBURGHADJUSTED LOCATIONTOTAL FACTOR ($)
AREA($/sq.ft.) (sq.ft.) COSTTOTAL PER UNIT COSTTOTAL PER UNIT AREA($/sq.ft.) (sq.ft.) COST PER UNIT ($/sq.ft.)
EXISTING HOUSE VALUE ($) EXISTING HOUSE VALUE ($) EXISTING HOUSE VALUE ($) TOTAL UNIT COST ($/unit) TOTAL UNIT COST ($/unit) TOTAL UNIT COST ($/unit) IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
0.66
34
PITTSBURGH FACTOR TOTAL COST OFLOCATION ADDITION ($) TOTAL COST OF ADDITION ($) TOTAL AREA (sq.ft.) TOTAL COST OF ADDITION ($)
IMP3.00
1.16 1.16 1.39 1.39 0.6 1.16 0.6 0.27 1.39 0.27 0.02 0.6 0.02 0.27
2" Polyurethane Rigid Foam Insulation 2" Polyurethane Rigid fiberglass Foam Insulation 12" R-38 high Density blacket insulation 12" R-38 high Density blacket insulation 2" Polyurethane Rigid fiberglass Foam Insulation
.5 x .5
7210-01 7210-01 07210-02 07210-02 7210-01
$17.34 $17.34 $0.00 $0.00 $17.34 $0.00 $876.96 $0.00 $876.96 $0.00 $876.96
2 2
05120-01 Steel lintel
07210-02 EXTERIOR INSULATION AND FINISH SYSTEM EXTERIOR INSULATION AND FINISH SYSTEM 07240-01 07240-01 EXTERIOR INSULATION AND FINISH SYSTEM
PLASTIC GLAZING PLASTIC GLAZING PLASTIC GLAZING FINISHES FINISHES FINISHES
COST PER UNITY ($ / UNIT) COST PER UNITY ($ / UNIT)
05120-01 Steel lintel 05120-01 Steel lintel
BUILDING INSULATION BUILDING INSULATION BUILDING INSULATION
WINDOW WINDOW WINDOW
UNIT QUANTITY UNIT QUANTITY
2250-01 2250-01
4081
STRUCTURAL STEEL STRUCTURAL STEEL STRUCTURAL STEEL WOOD FRAMING WOOD FRAMING WOOD FRAMING
SYSTEM SYSTEM
9 9 0.0662 0.0662 9 0.0662 0.10 0.10 0.98 0.10 0.98 0.98
$2.65 $23,165.22 $23,165.22 $2,316.52 $2,316.52 $25,481.74 $23,165.22 $25,481.74 $24,972.11 $2,316.52 $24,972.11 $25,481.74 $24,972.11 $24,972.11 1620 $24,972.11 1620 $15.41 $15.41 1620 $15.41 $78,000.00 $78,000.00 $78,000.00 $63.56 $63.56 $63.56
Pittsburgh Program for the Adaptive Transformation of Community Housing
ARC48_550
HEAT LOSS CALCULATION : INSULATION Existing Conditions
U value
total area sqft
New Conditions
heat loss coefficient
new U value .067
170.85
.0241
15.9
Wall
.289
2550
736.9
Window
.5
197.9
98.95
Roof
.339
1010
342.4
Floor
.287
660
189.7
Infiltration
AC x .018 x volume cu. ft
new heat loss coefficient
1.5 x .018 x 13,200 = 356.4 TOTAL HEAT LOSS COEFFICIENT (total UA): Peak Heat Loss =
1724.35 (existing)
1158.3 (new)
total ua x t (design indoor F - design outdoor F) 108634.06=1724.35 x (68 - 5 =) 63
Annual Heat Loss = total ua x 24 hrs x annual degree days 246982099.2 mmbtu=1724.35 x 24 x 5968 Building Energy Performance: 246982099.2 mmbtu/1320 sq ft = 187107.65 Heating total =
UA x 24 1724.35 x 24 = 41384.4
27799.2
CALCULATED HEATING EXPENSES 41384.4x 5968 = 246982099.2 = 246.9/ .70 = 352.7 x 12.12 = $4274.89 (existing) 27799.2 x 5968= 165905625.6 = 165.9/.70 = 237 x 12.12 = $2872.44 (new) Using insulation on the interior walls and ceiling of the basement and second floor drastically reduce the heating expenses to $2872.44, with a total savings of $1402.45 per year. TOTAL COST OF INSULATION: $3316 TOTAL PAYBACK TIME: 28.5 months = 2.3 years
insulation
$4274.89
+
=
$2872.44
$3316
IMPLEMENTATION DOCUMENTATION: CRITICAL PATH ANALYSIS
IMP3.01