Smart Solutions Infrastructure

Page 1

Smart Solutions Intelligent, integrated infrastructure for the data center

1


Top Data Center Challenges External forces changing the business climate

Virtualization, Cloud

IT Outsourcing

Consolidation

Infrastructure Management Heat Density

Efficiency & Green initiatives

Regulation Compliance

Facility Challenges

Availability Energy Efficiency

Higher Density

Business & technology forces pressing on the data center

Increasing Demand Reduced Budget

Power Density Source: Data Center Users’ Group Survey

2


Data Center Lifecycle Efficiency Design & Deployment

Management & Planning

Operation

Efficiency Without Compromise™ Design & Deployment

Operation

Management

     

  

Increase energy efficiency Reduce capital costs Reduce space Faster deployment Lower engineering costs Improve design efficiency

Free up stranded capacity Increase availability Reduce energy costs with efficient technologies

  

Efficiency is not just lowering operating costs Efficiency should apply to all aspects of operations

Streamline operations with management controls Improve asset utilization Simplify change management Lower long-term operational costs with proactive maintenance programs


Smart Solutions Family

4


Smart Solutions From Emerson Network Power

 An integrated data center infrastructure – Power, Cooling – Racks, Power Distribution – Infrastructure and IT Management

What makes these solutions unique? Efficient Economical Interoperable Control

• Enhance business, space, energy efficiency • Rapid deployment, easy servicing

• Make use of existing infrastructure • Avoid expensive room upgrades • Simple and flexible design and implementation • Systems work together • Optimized planning, monitoring and management • Control your IT environment

5


Industry Best Practices for Data Center Design and Operation Smart Solution infrastructure integrates industry best practices in data center design and operation: – – – – – –

Air flow management: Hot aisle / cold aisle; cold aisle containment High availability, high efficiency UPS Highest efficiency precision cooling; variable capacity /intelligent controls Space-savings, minimal footprint Modularity for flexibility and easier expansion Integrated monitoring and control for efficiency in planning and management Unique local service for design audits, configuration support, installation support, maintenance and repair

6


SmartRow

TM

7


Introducing SmartRow

TM

Intelligent, integrated infrastructure in a self contained line-up

Needs Addressed

Applications • • • •

Capacity: 20kW Racks: 3-6 Floor: Primarily non-raised Key Applications: Small data centers; remote sites

• • • • •

Integrated design Standardization Low 1st cost & operating cost Availability Speed of deployment

8


SmartRow - What is it? TM

 Single line of racks  Complete and integrated

data center infrastructure – 3-6 racks (up to 20kW) – Integrated Cooling – Airflow Management – Fire Suppression – UPS – Power Distribution – Monitoring

9


SmartRow - Component Details TM

High efficiency precision cooling – –

Downflow 5-Ton Liebert Challenger Air, Water/Glycol or Chilled Water

Supply air plenum

Fire suppression

Integrated electrical panel

Monitoring Panel

Reliable on-line UPS

Cool air up front of racks

Knurr DCM racks

Rack PDU

Return air plenum

Back up cooling

Room connections

Start-up

Full 1-yr warranty

10


SmartRow Benefits TM

Efficient

• Significant energy savings from enclosed precision cooling system, variable capacity and intelligent controls • Optimizes space efficiency through integrated system

Economical

• Room neutral: No effect on existing space • Reduce cost of installation: no need to undertake expensive upgrades to fire suppression, cooling capacity or flooring

Interoperable

• Can be deployed in just weeks: simple in design & deployment • Local data center experts and service teams for configuration, installation, maintenance, repair

Control

• Monitors temperature and controls precision cooling operating levels accordingly • Monitors equipment for quicker response & resolution

11


SmartRow Design & Cost Example TM

Situation: deploy 18 kW of IT to a non-IT ready room Conventional Design 18 kW, 288 sq ft 1 rows, 6 racks Ceiling mounted ducted cooling (6) 5 kVA UPS Room renovation, fire suppression

SmartRow 18 kW, 288 sq ft 1 rows, 6 racks 1 Liebert Challenger (downflow) 6 Liebert GXT 5 kVA Room neutral

12


SmartRow Cost Comparison TM

Conventional

SmartRow

Cost Savings

% Savings

$60,000

$43,000

$17,000

28%

$105,000

$109,000

-$4,000

-3%

$165,000

$152,000

$13,000

8%

$8,800

$6,400

$2,400

27%

5 Year OpEx

$44,000

$32,000

$12,000

27%

5 Year TCO

$209,000

$184,000

$25,000

12%

Room Costs contractor, installation, engineering services

Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression

Total CapEx Annual Energy Consumption power & cooling equipment energy use

Room Savings

Room neutral, fewer services to retrofit room into an IT space

Equipment Savings

Pre-engineered, integrated precision cooling, ducting, distribution and fire suppression

Energy Savings

Airflow management, variable capacity, intelligent controls 13


SmartMod

TM

14


Introducing SmartMod

TM

Intelligent, integrated infrastructure in a rapid- deployment enclosure

Segment Profile • • • •

Capacity: 30-400kW Racks: 6-28 Floor: N/A Applications: Supplemental capacity; remote data centers; disaster recovery

Needs Addressed • Simplicity – Fully integrated design

• Flexibility & Availability – N, N+1 or 2N

• Standardization • Speed of deployment

15


SmartMod - What is it? TM

 Rapid deployment IT enclosure

– Racks – Distribution – UPS – Precision Cooling & Condenser – Transfer Switch – Fire Suppression – Monitoring & Management  Server Neutral

16


SmartMod

TM

30-90 kW Component Details

Specifications Components Input Voltage Rack Space Density Total IT Load Power Redundancy Cooling Redundancy Footprint Heat Rejection Equipment

30kW SmartMod

30 kW

90 kW (or 75kW

N+1)

Cooling, UPS, distribution, Cooling, UPS, distribution, fire & monitoring fire & monitoring 480 or 208 VAC 3-Phase 480 or 208 VAC 3-Phase 9 racks, 378 U 8 Racks, 336 U 3.33kW / rack 11.25kW / 9.3kW per rack 30 kW 90kW – N / 75kW – N+1 N+1 N or N+1 N+1 N or N+1 11.5’W x 40’L 11.5’W x 53’L Integrated Integrated

90kW / 75kW SmartMod 17


SmartMod – 200 kW Component Details TM

IT Container

200 kW

Input Voltage

480 VAC 3-Phase

Rack Space

14 racks, 588U

Power Container

200 kW

400 kW

In /out Voltage

480 VAC 3Phase

480 VAC 3Phase

14 kW / rack

Total IT Load

200 kW

400 kW

Total IT Load

200 kW

Power Redundancy

N or 2N

Power Redundancy

N or 2N

N or 2N

Cooling Redundancy

N+1

Cooling Redundancy

2N

2N

Footprint

11.5’W x 40’L

11.5’W x 53’L

Heat Rejection Equipment

External Condensers

External Condensers

Density

Footprint Heat Rejection Equipment

11.5’W x 53’L Chilled Water or External for DX

200kW SmartMod IT Enclosure

200kW SmartMod Power Enclosure

18


SmartMod - Applications TM

 Capacity Overflow

– Short term: bridge until expansion or new data center is completed – Long term: modular data center, grow as you need it  Remote locations

– Designed with secure access, remote monitoring – All weather construction – Where chilled water is not available  Disaster recovery

– Utilize for short term capacity overflow then re-deploy as DR

Other containers: “just give me X amount of reliable power and chilled water and I can plug in my pod” – That doesn’t solve the problem: lack of extra power and cooling – SmartMod makes the difficult part easy: power & cooling 19


SmartMod Benefits TM

Efficient

• High-efficiency power and cooling technologies reduce power consumption versus conventional data centers • Pre-engineered systems, can be installed in just months

Economical

• Doesn’t burden existing power and cooling infrastructure • Reduce cost of installation: no need to undertake expensive expansion of existing data center or construction of new data center

Interoperable

• Pre-engineered infrastructure, designed and matched for the most common data center densities • Management software integrates with existing systems • Local data center experts and service teams for configuration, installation, preventive maintenance, repair

Control

• Remotely monitor infrastructure and environmental conditions • Remotely monitor security and access

20


SmartMod Design & Cost Example TM

Situation: build a space for 75 kW of IT Conventional Design 75 kW, 921 sq ft 1 row, 13 racks 3 perimeter cooling units (N+1) (2) 100 kVA UPS (N+1) Build a new building

SmartMod 75 kW, 609 sq ft 1 row, 8 racks 4 Liebert CRV (N+1), iCOM 1 Liebert APM 90 kVA UPS (N+1) Deploy enclosure

21


SmartMod Cost Comparison TM

Room Costs

Conventional

SmartMod

Cost Savings

% Savings

$579,000

$84,000

$495,000

85%

$315,000

$772,000

-$457,000

-145%

$894,000

$856,000

$38,000

4%

$31,000

$22,000

$9,000

29%

$155,000

$110,000

$45,000

29%

$966,000

$83,000

8%

contractor, installation, engineering services

Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression

Total CapEx Annual Energy Consumption power & cooling equipment energy use

5 Year OpEx

5 Year TCO $1,049,000

Room Savings Equipment Savings Energy Savings

Pre-engineered, no room, utilize enclosure, costs related to install and start up Equipment costs are the enclosure; which is the entire data center Airflow management, EC fans, digital scroll, intelligent cooling controls, no chilled water 22


SmartAisle

TM

23


Introducing SmartAisle

TM

Intelligent, integrated infrastructure using row-based building blocks

Applications • Capacity: Most cost effective up to 400kW • Floor: Raised, non-raised • Applications: Small and medium data centers; highdensity zones

Needs Addressed • • • • •

Efficiency: OPEX & CAPEX Flexibility Availability Standardization Interoperability

24


SmartAisle - What is it? TM

 Approach which combines the many disparate

parts of the IT infrastructure… • • • •

Racks Rack PDUs Busway Power Distribution

• • • •

UPS Precision Cooling Cooling Controls Containment

• • • •

Monitoring: Rack & Row Out of Band Management Startup and Maintenance Other services

25


SmartAisle - What is it? TM

 Approach which combines the many disparate

parts of the IT infrastructure… • • • •

Liebert CRV Knurr racks Liebert APM Cold Aisle Containment

• • • •

Liebert MPX Liebert MPH Liebert Nform / Site Scan Liebert MB Busway

• • • •

Avocent appliances Assessment services Liebert Installation / Startup Liebert PM services

…into a connected system which works together to improve cost, availability and management 26


SmartAisleTM - Component Details Cooling

Power

Racks Liebert MB

Liebert CRV Liebert APM

Infrastructure Management Avocent Serial Console

Avocent Service Processor Manager

Kn端rr DCM

LCD Console

Liebert RDU

Liebert iCom

Avocent Data Center Planner Avocent DS View

Rack PDU

Monitoring

Avocent KVM Switch

Sensors

Detectors

Liebert Nform

Alarms

Kn端rr DI Liebert MPX, MPH Avocent PM

27


SmartAisle Benefits TM

Efficient

• Increase energy efficiency using high-efficiency row-based cooling systems and containment • Streamlines IT productivity through management software and remote monitoring and control of infrastructure systems

Economical

• Can be used to retrofit existing infrastructure to support higher capacity and density • Modular design lets you pay only for what you need today

Interoperable

• Racks, cooling, power modules fit together for easy design and change management • Local data center experts and service teams for configuration, installation, preventive maintenance, repair

Control

• Streamlines IT planning to optimize space / capacity utilization • Monitors equipment to reduce break/fix events • Monitors power, temperature and humidity and controls equipment operating levels 28


SmartAisle Design & Cost Example TM

Situation: deploy 160 kW of IT to a floor

Conventional Design 160 kW, 1482 sq ft 3 rows, 27 racks 4 perimeter cooling units (1) 200 kVA UPS 3 distribution cabinets

SmartAisle 160 kW, 870 sq ft 2 rows, 16 racks 4 Liebert CRV, iCOM, Containment 2 Liebert APM 90 kVA UPS Liebert MB busway

29


SmartAisle Cost Comparison TM

Conventional

SmartAisle

Cost Savings

% Savings

$515,000

$459,000

$56,000

11%

$415,000

$391,000

$24,000

6%

$930,000

$850,000

$80,000

9%

$63,600

$46,600

$17,000

27%

5 Year OpEx

$318,000

$233,000

$85,000

27%

5 Year TCO

$1,248,000

$1,083,000

$165,000

13%

Room Costs contractor, installation, engineering services

Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression

Total CapEx Annual Energy Consumption power & cooling equipment energy use

Room Savings

Pre-configured = less engineering, easier install

Equipment Savings

Less cooling equipment with containment, fewer racks, less distribution, modular UPS

Energy Savings

Airflow management, EC fans, digital scroll, intelligent cooling controls, containment 30


Smart Solutions - Summary Smart Solutions

SmartRowTM

SmartModTM

SmartAisleTM

Ideal Applications

Non-traditional space Disaster recovery

Non-traditional space Disaster recovery Auxiliary capacity

Data Center High Density Pod

20 kW

30-90 kW 200-400 kW

Most cost effective up to 400 kW

kW per Rack

2 to 4 kW / rack

5 to 14 kW / rack

5 to 30 kW / rack

Key Benefits

Fully integrated, standalone roomneutral system

All in one design, just add servers and network connection

Standardized solution building blocks

Capacity

Example Layout

31


Smart Solutions From Emerson Network Power

How will data center needs be met? Around technology on a boxby-box basis?

or

Around a data center wide approach to efficient design?

Smart solutions for efficient design Efficient Economical Interoperable Control

• Enhance business, space, energy efficiency • Rapid deployment, easy servicing

• Make use of existing infrastructure • Avoid expensive room upgrades • Simple and flexible design and implementation • Systems work together • Optimized planning, monitoring and management • Control your IT environment

32


Thank You!