Smart Solutions Intelligent, integrated infrastructure for the data center
1
Top Data Center Challenges External forces changing the business climate
Virtualization, Cloud
IT Outsourcing
Consolidation
Infrastructure Management Heat Density
Efficiency & Green initiatives
Regulation Compliance
Facility Challenges
Availability Energy Efficiency
Higher Density
Business & technology forces pressing on the data center
Increasing Demand Reduced Budget
Power Density Source: Data Center Users’ Group Survey
2
Data Center Lifecycle Efficiency Design & Deployment
Management & Planning
Operation
Efficiency Without Compromise™ Design & Deployment
Operation
Management
Increase energy efficiency Reduce capital costs Reduce space Faster deployment Lower engineering costs Improve design efficiency
Free up stranded capacity Increase availability Reduce energy costs with efficient technologies
Efficiency is not just lowering operating costs Efficiency should apply to all aspects of operations
Streamline operations with management controls Improve asset utilization Simplify change management Lower long-term operational costs with proactive maintenance programs
Smart Solutions Family
4
Smart Solutions From Emerson Network Power
An integrated data center infrastructure – Power, Cooling – Racks, Power Distribution – Infrastructure and IT Management
What makes these solutions unique? Efficient Economical Interoperable Control
• Enhance business, space, energy efficiency • Rapid deployment, easy servicing
• Make use of existing infrastructure • Avoid expensive room upgrades • Simple and flexible design and implementation • Systems work together • Optimized planning, monitoring and management • Control your IT environment
5
Industry Best Practices for Data Center Design and Operation Smart Solution infrastructure integrates industry best practices in data center design and operation: – – – – – –
–
Air flow management: Hot aisle / cold aisle; cold aisle containment High availability, high efficiency UPS Highest efficiency precision cooling; variable capacity /intelligent controls Space-savings, minimal footprint Modularity for flexibility and easier expansion Integrated monitoring and control for efficiency in planning and management Unique local service for design audits, configuration support, installation support, maintenance and repair
6
SmartRow
TM
7
Introducing SmartRow
TM
Intelligent, integrated infrastructure in a self contained line-up
Needs Addressed
Applications • • • •
Capacity: 20kW Racks: 3-6 Floor: Primarily non-raised Key Applications: Small data centers; remote sites
• • • • •
Integrated design Standardization Low 1st cost & operating cost Availability Speed of deployment
8
SmartRow - What is it? TM
Single line of racks Complete and integrated
data center infrastructure – 3-6 racks (up to 20kW) – Integrated Cooling – Airflow Management – Fire Suppression – UPS – Power Distribution – Monitoring
9
SmartRow - Component Details TM
High efficiency precision cooling – –
Downflow 5-Ton Liebert Challenger Air, Water/Glycol or Chilled Water
Supply air plenum
Fire suppression
Integrated electrical panel
Monitoring Panel
Reliable on-line UPS
Cool air up front of racks
Knurr DCM racks
Rack PDU
Return air plenum
Back up cooling
Room connections
Start-up
Full 1-yr warranty
10
SmartRow Benefits TM
Efficient
• Significant energy savings from enclosed precision cooling system, variable capacity and intelligent controls • Optimizes space efficiency through integrated system
Economical
• Room neutral: No effect on existing space • Reduce cost of installation: no need to undertake expensive upgrades to fire suppression, cooling capacity or flooring
Interoperable
• Can be deployed in just weeks: simple in design & deployment • Local data center experts and service teams for configuration, installation, maintenance, repair
Control
• Monitors temperature and controls precision cooling operating levels accordingly • Monitors equipment for quicker response & resolution
11
SmartRow Design & Cost Example TM
Situation: deploy 18 kW of IT to a non-IT ready room Conventional Design 18 kW, 288 sq ft 1 rows, 6 racks Ceiling mounted ducted cooling (6) 5 kVA UPS Room renovation, fire suppression
SmartRow 18 kW, 288 sq ft 1 rows, 6 racks 1 Liebert Challenger (downflow) 6 Liebert GXT 5 kVA Room neutral
12
SmartRow Cost Comparison TM
Conventional
SmartRow
Cost Savings
% Savings
$60,000
$43,000
$17,000
28%
$105,000
$109,000
-$4,000
-3%
$165,000
$152,000
$13,000
8%
$8,800
$6,400
$2,400
27%
5 Year OpEx
$44,000
$32,000
$12,000
27%
5 Year TCO
$209,000
$184,000
$25,000
12%
Room Costs contractor, installation, engineering services
Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression
Total CapEx Annual Energy Consumption power & cooling equipment energy use
Room Savings
Room neutral, fewer services to retrofit room into an IT space
Equipment Savings
Pre-engineered, integrated precision cooling, ducting, distribution and fire suppression
Energy Savings
Airflow management, variable capacity, intelligent controls 13
SmartMod
TM
14
Introducing SmartMod
TM
Intelligent, integrated infrastructure in a rapid- deployment enclosure
Segment Profile • • • •
Capacity: 30-400kW Racks: 6-28 Floor: N/A Applications: Supplemental capacity; remote data centers; disaster recovery
Needs Addressed • Simplicity – Fully integrated design
• Flexibility & Availability – N, N+1 or 2N
• Standardization • Speed of deployment
15
SmartMod - What is it? TM
Rapid deployment IT enclosure
– Racks – Distribution – UPS – Precision Cooling & Condenser – Transfer Switch – Fire Suppression – Monitoring & Management Server Neutral
16
SmartMod
TM
30-90 kW Component Details
Specifications Components Input Voltage Rack Space Density Total IT Load Power Redundancy Cooling Redundancy Footprint Heat Rejection Equipment
30kW SmartMod
30 kW
90 kW (or 75kW
N+1)
Cooling, UPS, distribution, Cooling, UPS, distribution, fire & monitoring fire & monitoring 480 or 208 VAC 3-Phase 480 or 208 VAC 3-Phase 9 racks, 378 U 8 Racks, 336 U 3.33kW / rack 11.25kW / 9.3kW per rack 30 kW 90kW – N / 75kW – N+1 N+1 N or N+1 N+1 N or N+1 11.5’W x 40’L 11.5’W x 53’L Integrated Integrated
90kW / 75kW SmartMod 17
SmartMod – 200 kW Component Details TM
IT Container
200 kW
Input Voltage
480 VAC 3-Phase
Rack Space
14 racks, 588U
Power Container
200 kW
400 kW
In /out Voltage
480 VAC 3Phase
480 VAC 3Phase
14 kW / rack
Total IT Load
200 kW
400 kW
Total IT Load
200 kW
Power Redundancy
N or 2N
Power Redundancy
N or 2N
N or 2N
Cooling Redundancy
N+1
Cooling Redundancy
2N
2N
Footprint
11.5’W x 40’L
11.5’W x 53’L
Heat Rejection Equipment
External Condensers
External Condensers
Density
Footprint Heat Rejection Equipment
11.5’W x 53’L Chilled Water or External for DX
200kW SmartMod IT Enclosure
200kW SmartMod Power Enclosure
18
SmartMod - Applications TM
Capacity Overflow
– Short term: bridge until expansion or new data center is completed – Long term: modular data center, grow as you need it Remote locations
– Designed with secure access, remote monitoring – All weather construction – Where chilled water is not available Disaster recovery
– Utilize for short term capacity overflow then re-deploy as DR
Other containers: “just give me X amount of reliable power and chilled water and I can plug in my pod” – That doesn’t solve the problem: lack of extra power and cooling – SmartMod makes the difficult part easy: power & cooling 19
SmartMod Benefits TM
Efficient
• High-efficiency power and cooling technologies reduce power consumption versus conventional data centers • Pre-engineered systems, can be installed in just months
Economical
• Doesn’t burden existing power and cooling infrastructure • Reduce cost of installation: no need to undertake expensive expansion of existing data center or construction of new data center
Interoperable
• Pre-engineered infrastructure, designed and matched for the most common data center densities • Management software integrates with existing systems • Local data center experts and service teams for configuration, installation, preventive maintenance, repair
Control
• Remotely monitor infrastructure and environmental conditions • Remotely monitor security and access
20
SmartMod Design & Cost Example TM
Situation: build a space for 75 kW of IT Conventional Design 75 kW, 921 sq ft 1 row, 13 racks 3 perimeter cooling units (N+1) (2) 100 kVA UPS (N+1) Build a new building
SmartMod 75 kW, 609 sq ft 1 row, 8 racks 4 Liebert CRV (N+1), iCOM 1 Liebert APM 90 kVA UPS (N+1) Deploy enclosure
21
SmartMod Cost Comparison TM
Room Costs
Conventional
SmartMod
Cost Savings
% Savings
$579,000
$84,000
$495,000
85%
$315,000
$772,000
-$457,000
-145%
$894,000
$856,000
$38,000
4%
$31,000
$22,000
$9,000
29%
$155,000
$110,000
$45,000
29%
$966,000
$83,000
8%
contractor, installation, engineering services
Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression
Total CapEx Annual Energy Consumption power & cooling equipment energy use
5 Year OpEx
5 Year TCO $1,049,000
Room Savings Equipment Savings Energy Savings
Pre-engineered, no room, utilize enclosure, costs related to install and start up Equipment costs are the enclosure; which is the entire data center Airflow management, EC fans, digital scroll, intelligent cooling controls, no chilled water 22
SmartAisle
TM
23
Introducing SmartAisle
TM
Intelligent, integrated infrastructure using row-based building blocks
Applications • Capacity: Most cost effective up to 400kW • Floor: Raised, non-raised • Applications: Small and medium data centers; highdensity zones
Needs Addressed • • • • •
Efficiency: OPEX & CAPEX Flexibility Availability Standardization Interoperability
24
SmartAisle - What is it? TM
Approach which combines the many disparate
parts of the IT infrastructure… • • • •
Racks Rack PDUs Busway Power Distribution
• • • •
UPS Precision Cooling Cooling Controls Containment
• • • •
Monitoring: Rack & Row Out of Band Management Startup and Maintenance Other services
25
SmartAisle - What is it? TM
Approach which combines the many disparate
parts of the IT infrastructure… • • • •
Liebert CRV Knurr racks Liebert APM Cold Aisle Containment
• • • •
Liebert MPX Liebert MPH Liebert Nform / Site Scan Liebert MB Busway
• • • •
Avocent appliances Assessment services Liebert Installation / Startup Liebert PM services
…into a connected system which works together to improve cost, availability and management 26
SmartAisleTM - Component Details Cooling
Power
Racks Liebert MB
Liebert CRV Liebert APM
Infrastructure Management Avocent Serial Console
Avocent Service Processor Manager
Kn端rr DCM
LCD Console
Liebert RDU
Liebert iCom
Avocent Data Center Planner Avocent DS View
Rack PDU
Monitoring
Avocent KVM Switch
Sensors
Detectors
Liebert Nform
Alarms
Kn端rr DI Liebert MPX, MPH Avocent PM
27
SmartAisle Benefits TM
Efficient
• Increase energy efficiency using high-efficiency row-based cooling systems and containment • Streamlines IT productivity through management software and remote monitoring and control of infrastructure systems
Economical
• Can be used to retrofit existing infrastructure to support higher capacity and density • Modular design lets you pay only for what you need today
Interoperable
• Racks, cooling, power modules fit together for easy design and change management • Local data center experts and service teams for configuration, installation, preventive maintenance, repair
Control
• Streamlines IT planning to optimize space / capacity utilization • Monitors equipment to reduce break/fix events • Monitors power, temperature and humidity and controls equipment operating levels 28
SmartAisle Design & Cost Example TM
Situation: deploy 160 kW of IT to a floor
Conventional Design 160 kW, 1482 sq ft 3 rows, 27 racks 4 perimeter cooling units (1) 200 kVA UPS 3 distribution cabinets
SmartAisle 160 kW, 870 sq ft 2 rows, 16 racks 4 Liebert CRV, iCOM, Containment 2 Liebert APM 90 kVA UPS Liebert MB busway
29
SmartAisle Cost Comparison TM
Conventional
SmartAisle
Cost Savings
% Savings
$515,000
$459,000
$56,000
11%
$415,000
$391,000
$24,000
6%
$930,000
$850,000
$80,000
9%
$63,600
$46,600
$17,000
27%
5 Year OpEx
$318,000
$233,000
$85,000
27%
5 Year TCO
$1,248,000
$1,083,000
$165,000
13%
Room Costs contractor, installation, engineering services
Infrastructure Equipment UPS, distribution, cooling, racks, fire suppression
Total CapEx Annual Energy Consumption power & cooling equipment energy use
Room Savings
Pre-configured = less engineering, easier install
Equipment Savings
Less cooling equipment with containment, fewer racks, less distribution, modular UPS
Energy Savings
Airflow management, EC fans, digital scroll, intelligent cooling controls, containment 30
Smart Solutions - Summary Smart Solutions
SmartRowTM
SmartModTM
SmartAisleTM
Ideal Applications
Non-traditional space Disaster recovery
Non-traditional space Disaster recovery Auxiliary capacity
Data Center High Density Pod
20 kW
30-90 kW 200-400 kW
Most cost effective up to 400 kW
kW per Rack
2 to 4 kW / rack
5 to 14 kW / rack
5 to 30 kW / rack
Key Benefits
Fully integrated, standalone roomneutral system
All in one design, just add servers and network connection
Standardized solution building blocks
Capacity
Example Layout
31
Smart Solutions From Emerson Network Power
How will data center needs be met? Around technology on a boxby-box basis?
or
Around a data center wide approach to efficient design?
Smart solutions for efficient design Efficient Economical Interoperable Control
• Enhance business, space, energy efficiency • Rapid deployment, easy servicing
• Make use of existing infrastructure • Avoid expensive room upgrades • Simple and flexible design and implementation • Systems work together • Optimized planning, monitoring and management • Control your IT environment
32
Thank You!