Euroteknika Catalogue 2014 en

Page 1

P R O D U C T S C A TA L O G U E 2 0 14

teknika

p -A

Fr

Manu ench factu ring

teknika

global s ol

gy - eu ro olo t n

ka gro kni u te

teknika

Implants that adhere to the strictest regulations in the field

s

i f e

L

A global solution FOR IMPLANTOLOGY

a

e

lab

m

teknika

i

teknika

P R O D U C T S C A T A L O G U E 2 0 14

for imp la ion ut

A GLOBAL SOLUTION F O R I M P L A NTO LOGY

t

i

euroteknika 726 rue du GĂŠnĂŠral De Gaulle - 74700 SALLANCHES - France

Tel.: +33 (0)4 50 91 49 20 - Fax: +33 (0)4 50 91 98 66 sales@euroteknika.com - www.euroteknika.com catalogue_GB_2014_0514

A global solution for implantology Imprimerie PLANCHER - Bonneville


L

e

euroteknika WARRANTY i f e FOR IMPLANTS & PROSTHETIC COMPONENTS

m

im

lant s

p

t

IMPLANTS: A LIFETIME WARRANTY undertakes to replace free of charge any euroteknika implant that meets the terms of the warranty.

n euroteknika

n euroteknika only guarantees to replace euroteknika implants and prosthetic components

linked to the defective implant with a similar euroteknika implant and prosthetic components which have been placed in a similar way (only the diameter and / or length may be modified). If euroteknika is unable to replace the items with the same reference, the items will be replaced by a similar product of equivalent value. n

PROSTHETIC COMPONENTS: A 10-YEAR WARRANTY n    euroteknika undertakes to replace free of charge any defective euroteknika component of a permanent prosthesis with the same reference. n     euroteknika will also replace free of charge any component of a euroteknika permanent prosthesis or any euroteknika implant related to the defective euroteknika prosthetic component with a euroteknika prosthetic component or implant, if this prosthetic component or implant needs to be replaced at the same time as the defective prosthetic component.

For further information concerning the conditions and scope of the euroteknika warranty, you can consult the information booklet on our website: www.euroteknika.com or contact your sales advisor.

, this warranty s regarding any question contact us: if you have hesitate to please do not 50 91 49 20 Tel.: +33 (0)4 euroteknika.com ches – France Email : sales@ - 74700 Sallan Général De Gaulle uroteknika.com le online: www.e

rue du Adresse: 726

This euro

ty is availab tekn ika warran

OUR NTY WAR R A TS FOR IM PLAN ETIC & PROSTH TS COMPON EN

ion FOr A global solut

IMPL ANTO

LOGY

S - France ika SALLANCHE 98 66 Gaulle - 74700 (0)4 50 91 Général De - Fax : 33 726 rue du aux 50 91 49 20 Ils sont conformes qui e prothèse dentaire. Tél. : 33 (0)4 à soutenir une de la santé bucco-dentair sont destinés 93/42 CEE. Ils _GB_0612 ka.com que par des professionnels

eurotekn

Européenne être posés tekni maladie. Garantier_ETK a ne peuvent IIb selon la Directive par l’assurance www.euro médicaux de Classe systèmes implantaires euroteknik pas remboursés a. Ils ne sont Les sont des dispositifs a par SNCH. euroteknik euroteknik CE0499 délivré et du manuel d’utilisation du marquage Les implants dentaires et bénéficient la notice d’instruction normes en vigueur du contenu de connaissance doivent avoir pris

2

i


Summary

IMPLANTS DESIGNED FOR A WIDE VARIETY OF CLINICAL SOLUTIONS I. IMPLANTS WITH DIRECT HANDLING

n COMMON FEATURES

6 12 20 28 48 62

n 1 - NATURACTIS n 2 - NATURALL+ n 3 - NATEA+

n 4 - AESTHETICA+2 n 5 - UNEVA+

II. IMPLANTS WITH IMPLANT-HOLDER

n 1 - NATURALL n 2 - NATEA

III. 6 MM SHORT IMPLANTS

WITH DIRECT HANDLING n 1 - NATURACTIS n 2 - NATURALL+ n 3 - NATEA+

n 4 - AESTHETICA+2 n 5 - UNEVA+

130

132 132 133 134 136 138

WITH IMPLANT-HOLDER n 6 - AESTHETICA+ n 7 - NATEA n 8 - UNEVA

140 140 142 142

VI. NARROW IMPLANTS NARROW IMPLANTS Ø 3MM

78 80 86 100 112

n 3 - AESTHETICA+ n 4 - UNEVA

4

144

n 1 - NATURACTIS Ø 3 MM n 2 - NATURALL+ Ø 3 MM MINI BALL IMPLANT Ø 2.7 MM n 3 - OBI Ø 2.7 MM

146 146 147 152 152

V. INSTRUMENTATION

154

VI. SYNTHETIC BONE SUBSTITUTE

162

VII. PRODUCTS AND SERVICES

164 3


teknika

4


I. Direct handling

I. IMPLANTS WITH DIRECT HANDLING

natea

naturall POST-EXTRACTION IMPLANT

ANATOMICAL IMPLANT

aesthetica

VERSATILE IMPLANT

2

TISSUE LEVEL IMPLANT

EXTERNAL CONNECTION IMPLANT

5


Common features

I. Direct handling

COMMON FEATURES teknika

IMPLANT SURFACE STAE  ®

Sandblasting Titanium Acid Etched

Micro-sandblasting with titanium oxide and acid etching (nitric and hydrofluoric acids) n n n n

Non-polluting subtractive treatment. Increased implant/bone contact area (+79.2%). Increased wettability. Stimulation of osteoconduction.

Sandblasting

A specific controlled sandblasting process n n n n

Constant pressure. Constant sandblasting speed. Constant grain size. Creation of a macrostructure.

Acid etching

Acid etching / passivation process and neutralization n Decontamination of the surface and formation of a T1O2 layer. n Creation of a microstructure. 20 years of clinical experience n Studies have been undertaken in collaboration with Angers University (France), the International University of Catalonia (Spain), Curkova University (Turkey) as well as the Universities of Hamburg (Germany), Iran, and Saint Joseph in Beirut (Lebanon).

Histological studies

Numerous histological studies n Much research has been carried out on the surface state of the implants in collaboration with Professor Chappard from the Histology Laboratory at Angers University (France), Prof. P. Bravetti from the faculty of dentistry in Nancy (France), Dr. Giner from the International University of Catalonia (Spain ), Prof. Jabbour from St Jospeh Faculty of Medicine in Beirut (Lebanon) and the Faculty of Medical Sciences at the University of Iran. n Histological observations on our implants show a large percentage of bone-to-implant contact between the titanium and the cortical bone, as well as newly formed bone of normal texture. n In a comparative statistical study carried out by Professor Chappard on Brånemark implants, it was shown that euroteknika implants are as reliable as mainstream implant brands. n The study on the osseointegration of 15 euroteknika implants conducted by the University of Iran and published in the Dental Research Journal (Vol. 8, No. 3, January 2014) shows a B.I.C. of 76.82% and an ISQ of 70.83 after 4 months.

6


n Verification of the entire surface of the implants under a microscope after treatment. n Periodic SEM examination to verify the homogeneity of the surface topography and to characterize the chemical contrast of the surface. n The chemical composition of the surface of our sanded and etched implants is determined using X-ray microanalysis (EDX). n Roughness parameters are measured according to ISO 4287 and surface roughness parameters according to ISO 25178 to monitor our production. n Roughness is measured on a sample every 200 implants. n Roughness is between 1.2 and 1.8 μm. n 3D analysis of the surface of our implants is performed using Altisurf sampling.

Succes rates n Multicentric clinical feedback over 7 years confirming the quality of our surface treatment, with a success rate superior to 98% for our range of implants.

Survey period: November 2006 – December 2013 Number of implants placed: 5479 Number of dentists: 32 Success rate: 98,38 %

naturall

Number of implants placed and loaded Total number of failures Number of failures before loading Number of failures after loading Number of failures due to the patient (i.e. bone density, pathology, hygiene) Number of failures due to the protocol or the treatment plan Number of unexplained failures

natea

5479 89 1,62% of failure 67 22 24 17 24

Survey period: June 2007 – December 2013 Number of implants placed: 2562 Number of dentists: 15 Success rate: 98,05 %

Number of implants placed and loaded Total number of failures Number of failures before loading Number of failures after loading Number of failures due to the patient (i.e. bone density, pathology, hygiene) Number of failures due to the protocol or the treatment plan Number of unexplained failures

2562 50 1,95% of failure 36 14 22 14 14

aesthetica

2

Survey period: January 2005 – December 2013 Number of implants placed: 4398 Number of dentists: 25 Success rate: 97,95 %

Number of implants placed and loaded Total number of failures Number of failures before loading Number of failures after loading Number of failures due to the patient (i.e. bone density, pathology, hygiene) Number of failures due to the protocol or the treatment plan Number of unexplained failures

4398 90 2,05% of failure 71 19 26 10 31

Survey period: September 2005 – December 2013 Number of implants placed: 1453 Number of dentists: 11 Success rate: 97,73 % Number of implants placed and loaded Total number of failures Number of failures before loading Number of failures after loading Number of failures due to the patient (i.e. bone density, pathology, hygiene) Number of failures due to the protocol or the treatment plan Number of unexplained failures

1453 33 2,27% of failure 7 0 0 5 2

7

I. Direct handling

Common features

Continuous analysis


Common features

Double thread The double thread allows the implant to be screwed in faster and limits bone overheating by inserting itself along two parallel grooves (only one of the two threads passes through each bone groove, the traumatism caused by friction is thus halved).

Thread A Thread B Protrusion A Protrusion B

Central protrusion between the threads* n This protrusion increases the bone-implant contact surface area by 15% to facilitate osteogenesis. n This change in geometry activates cell reconstruction.

Protrusion

I. Direct handling

Atraumatic, stable implants

* Available on our ranges of implants with direct handling

Optimization of primary stability Our protocols, designed for all bone densities, allow an excellent, controlled primary stability specific to euroteknika implants.

Asymmetrical rounded thread

MASTICATORY FORCES

The thread has been milled asymmetrically; this allows masticatory forces to be spread evenly along the lower face of the thread while the upper faces help prevent de-rotation of the implant.

X=Y X Y

Peaks of rounded threads = Better bone apposition

8


n n n n n

Microthread synchronous with the main thread to prevent avulsion of the cortical bone. Stabilization of the cortical bone by microstimulation. Optimization of the primary stability of the implant. Enhanced resistance to axial loads. Reduction in shear stress at the bone-implant interface.

First bone pit made by the main thread The active insertion of the microthread in the cortical zone

Atraumatic, active apex n A groove closer to the apex to improve the self-tapping effect of the threads. n The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage. n Safe to use in risky areas (sinus, dental nerve…).

Emergence switching The profile of the assembled implant-abutment is not linear, but has a concavity coronal to the fixture head as the abutment is narrower than the external diameter of the implant. This allows the development of a ring of connective tissue that provides: n Mechanical stability of the soft tissue. n Protection of the biological seal by reducing the risk of trauma to the soft tissue. n The concavity formed by the prosthetic junction isolates any inflammatory tissue. The 3mm of biological space needed to isolate and protect the crestal bone from the external environment is thus achieved by the greater length (A) of the prosthetic junction concavity rather than just the height (B). Therefore, despite the shorter crown-to-bone distance (C), a more efficient biological seal is obtained as it prevents placing the implant connection at bone level (see Fig 1). The concavity formed by the implant-abutment prosthetic junction isolates any inflammatory tissue from the bone crest (see Fig 2). Richard J. LAZZARA, Stephan S. PORTER (PDR, volume 26 no.1, 2006). Figure 1

Linear classical assembly

Assembly type « Emergence switching »

Figure 2

Spread surface

B

A

C

A

Healthy gingiva against the bone

B

A>B C = crown/bone distance A / B = mucous attachment surface

Inflammatory area

9

I. Direct handling

Common features

euroteknika exclusive microthread


Common features

I. Direct handling

Nitrided abutments Our titanium abutments are nitrided: this treatment makes it possible to preserve titanium biocompatibility and gingival integration while resulting in a less visible yellow coloring under the ceramic.

Adaptable analogs All analogs can be cut so they can be trimmed while ensuring the screw wells are not cut and to facilitate the assembly of the prosthesis on pins.

Can be cut

Anti-unscrewing design All the screws of cemented and screwed prostheses are covered with an amorphous carbon film limiting the coefficient of friction and making it possible to improve the screw joint by a greater tension of the screw.

“Unlosable” screw The screws of our prosthetic parts are retained inside the latter by a thread, thus preventing any unexpected loss.

Laser marking Healing abutments, straight and angulated trans-screwed abutments and solid abutments are laser-marked indicating their above-bone heights and their platforms.

10

Letter

Emergence diameter

E

Ø 3.6

N

Ø 4.6

R

Ø 5.2

W

Ø6

Indication of supracrestal gingival height Indication of prosthetic emergence

Sub-crestal implant: Naturactis Crestal implant: Naturall+ and Natea+


teknika

SIMPLIFICATION OF THE PROSTHETIC RANGE 1 unique prosthetic range with 4 prosthetic platforms n    For a simplified treatment plan = facilitates surgery and the construction of your prosthetics

Ex

Narr o tra

ep

ø 3.6

w

ø 3.5 ø4 ø 4.5 ø5

Na

rrow

ø 4.6

Re

gula r

ø 5.2

W id e

ø6

New Ø 3.6 mm narrow platform

naturall

n    Ideal for the anterior region and narrow spaces

SIMPLIFICATION OF THE CONNECTION

ø 3.5 ø4 ø 4.5 ø5

A single, unique connection n   To simplify the management of prosthetic parts between the dental office and the lab = to rationalize the inventory of your prosthetic components

A TRUSTED CONNECTION FOR 7 YEARS Numerous tests carried out

lant

e m

i f e

L

ø 3.6 ø 4.1 ø 4.8 ø6

p

s

im

natea

t

i

n    Proven mechanical resistance n    Over 200 fatigue tests (5 million cycles) carried out on 3 different types of implant

Astra® compatibility according to the references n    Please contact us for further information about compatibility

11

I. Direct handling

Common features

SIMPLICITY


I. Direct handling

teknika

12


I. Direct handling

P OST-EXTRACTION I M PL ANT

13


1 Naturactis

I. Direct handling

ACTIVE BY NATURE The Naturactis implant was developed to treat partial or complete tooth loss (mandible and maxilla). It can be used in different clinical cases, especially post-extraction surgery and low bone density areas. Implants are placed in a subcrestal position to improve the planning of the prosthetic restoration, the aesthetics and the management of the biological space.

Hexagon

A unique connection

Taper 11°

P

n Unique connection for all implant diameters and the 4 platforms = simplified management of prosthetic parts between the dental office and the lab. n Connection compatible* with the Astra®   (Ocean platform), Naturall+ and Natea+ prosthetic ranges. n Tapered internal connection (Morse Taper) guarantees the airtightness of the prosthetic joint and the stability of the abutment-implant connection (S.Dibart, M. Warbington, M. Fan Su, Z. Skobe). n The connection has an internal hexagon which allows the abutment to be orientated at the right angle. n The significant depth of the connection and the quality of the adjustments garantee good stability when putting the pieces together and prevent the prosthesis from unscrewing.

Slightly reversed taper of the neck for implantation in narrow ridges n n n n

The body of the implant acts as an osteotome. Reversed taper decreases cortical bone pressure. Facilitates placement of the implant even if the drilling site is under prepared. Facilitates placement in narrow crests.

Tapered implant body n Optimization of the primary stability.

*Please contact us for further information about compatibility.

14

ß°


n Optimal apical anchorage in low density bone. Oblique surface collects and condenses bone fragments

Increase primary stability of the implant

Depth of blade

n 2 helical and self-tapered grooves: they laterally cut the bone and condense it. n A minimal width groove keeps a maximum of the threads in the bone.

Cutting blade Width of groove of section

Narrow, active apex n n n n n n

Start of the thread in the form of a blade. Depth of blade greater on apical part than the body of the implant. Optimal anchorage in soft bone. Good self-tapping capacity. Ideal for post-extraction surgery. Facilitates the choice of implant axis.

Under drilling

Subcrestal position n Improved planning of post-extraction surgery. n Emergence switching. 0,5 mm

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

15

I. Direct handling

1 Naturactis

Thread depth increases at the apex


1 Naturactis

Ø 3.4 - 3.8 - 4.3 - 4.8

Synchronized microthreads 2.95 mm (6 threads)

Thread 0,4 mm

Ø 3.5 4 - 4.5 - 5

Thread features Real screw thread 2.4 mm

Sandblasted and etched length

I. Direct handling

Technichal features

Thread 1.2 mm

1.2 0.11 mm mm 2.4 mm 17°

25°

Ø 1.6 - 1.8 - 2.2 - 2.3

Implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Lenght «L»

Ø 3 mm

Ø 3.5 mm

Ø 4 mm

Ø 4.5 mm

Ø 5 mm

Ø 6 mm

6 mm

-

-

-

NIP 45 060**

NIP 50 060**

NIP 60 060**

8 mm

NIP 30 080*

NIP 35 080

NIP 40 080

NIP 45 080

NIP 50 080

-

10 mm

NIP 30 100*

NIP 35 100

NIP 40 100

NIP 45 100

NIP 50 100

-

12 mm

NIP 30 120*

NIP 35 120

NIP 40 120

NIP 45 120

NIP 50 120

-

14 mm

NIP 30 140*

NIP 35 140

NIP 40 140

NIP 45 140

NIP 50 140

-

16 mm

-

NIP 35 160

NIP 40 160

NIP 45 160

-

-

18 mm

-

NIP 35 180

NIP 40 180

-

-

-

* For 3 mm diameter implants: see presentation prosthetic panorama pages 149 - 151. ** For Ø 6 mm implants: consult emergence heights for Naturall+ (panorama pages 40 to 47). See presentation of the short implants and the specific surgical kit pages 132 - availability December 2014.

16

L


Mini surgical kit Ref. NIPK P0

This simplified kit includes all the instruments necessary to place Naturactis implants Ø 3.5 - 4 - 4.5 - 5 lengths 8, 10, 12 and 14 mm.

90 mm

170 mm

n A smaller size to gain space on the sterile field and in the autoclave. n The second plate can be inclined to better see the instruments during the surgery.

NIPK P0 CONTENTS

Direct implant key Mandrel extension Click wrench Direct implant mandrel External hexagonal key External hexagonal mandrel Point drills: Cylindrical initial drills Ø 2.2:

Drill Ø 2.2-2.8 Drill Ø 2.8-3.3 Drill Ø 3.3-3.8 Drill Ø 3.8-4.3 Drill Ø 4.3-4.8 Gauge Ø 2.2 Taps:

Directional indicators for implants

medium

CCP 35 30 CRM 340 CCC 120

short - 20 mm medium - 12 mm       long - 22 mm Ø 1.5 - 2.2 Ø 2.2 8 mm 10 mm 12 mm 14 mm short short short short short

CMP 35 20 CCL HE 12 22 CMA HE 12 22 CFP 15 22 50 NFP 22 180 NFP 22 22 080 NFP 22 22 100 NFP 22 22 120 NFP 22 22 140 NFP 22 28 140 NFP 28 33 140 NFP 33 38 140 NFP 38 43 140 NFP 43 48 140 NJP 22

Ø 3.5 Ø4 Ø 4.5 Ø5

NTP 35 100 NTP 40 100 NTP 45 100 NTP 50 100 NPG 16 100

Pictures for illustration purposes only

17

I. Direct handling

1 Naturactis

NEW


1 Naturactis

I. Direct handling

Complete surgical kit This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Naturactis implants Ă˜ 3.5 - 4 - 4.5 - 5, lengths 8, 10, 12, 14, 16 and 18. Ref. NIPT 00

1

2

3

4

1 - Integrated graduated ruler 2 - Numerical sequences of the instruments for calibrating the implant sockets 3 - Readibility of the sequences „ step by step presentation „ indications with arrows 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone. Pictures for illustration purposes only

18


4 mm square key for taps Mandrel extension Click wrench Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Adapter sleeve Point drills: Cylindrical initial drills Ø 2.2:

Drills Ø 2.2-2.8: Drills Ø 2.8-3.3: Drills Ø 3.3-3.8: Drills Ø 3.8-4.3: Drills Ø 4.3-4.8: Gingival gauge Gauge Ø 2.2 Depth gauges:

Taps:

Directional indicators for implants

short - 10 mm medium - 15 mm long - 20 mm

CCP 35 20 CCP 35 30 CCP 35 40 CEC 40 CRM 340 CCC 120

short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm       short - 22 mm long - 26 mm

CMP 35 20 CMP 35 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CAM 70 100

Ø 1.5 - 2.2 Ø 2.2 8 mm 10 mm 12 mm 14 mm 16 mm 18 mm short long short long short long short long short long

CFP 15 22 50 NFP 22 180 NFP 22 22 080 NFP 22 22 100 NFP 22 22 120 NFP 22 22 140 NFP 22 22 160 NFP 22 22 180 NFP 22 28 140 NFP 22 28 180 NFP 28 33 140 NFP 28 33 180 NFP 33 38 140 NFP 33 38 180 NFP 38 43 140 NFP 38 43 180 NFP 43 48 140 NFP 43 48 180 NJP 22 280 NJP 22

Ø 2.2-2.8 Ø 2.8-3.3 Ø 3.3-3.8 Ø 3.8-4.3 Ø 4.3-4.8 Ø 3.5 Ø4 Ø 4.5 Ø5

NJP 22 28 NJP 28 33 NJP 33 38 NJP 38 43 NJP 43 48 NTP 35 100 NTP 40 100 NTP 45 100 NTP 50 100 NPG 16 100

19

I. Direct handling

1 Direct implant keys:

Naturactis

NIPT 00 CONTENTS


I. Direct handling

teknika

20


I. Direct handling

ANATOM ICAL I M PL ANT

naturall

21


2 Naturall+

I. Direct handling

naturall

ANATOMICAL IMPLANT

The taper optimises implantation near curved roots, makes it possible to get much closer to the sinus cavities and offers a wider choice of positioning of implants that may be adjacent. The insertion of the implant is easier, guided by the direct insertion of the first third of the implant, and less aggressive thanks to the screwless insertion of the end of the implant; the cortical bone is under less strain and does not overheat during insertion of the upper part of the implant.

A unique connection n Unique connection for all implant diameters and the 4 platforms = simplified management of prosthetic parts between the dental office and the lab. n Connection compatible* with the AstraÂŽ (Ocean platform), Naturactis and Natea+ prosthetic ranges. n Tapered internal connection (Morse Taper) guarantees the airtightness of the prosthetic joint and the stability of the abutment-implant connection (S.Dibart, M. Warbington, M. Fan Su, Z. Skobe). n The connection has an internal hexagon which allows the abutment to be orientated at the right angle. n The significant depth of the connection and the quality of the adjustments garantee good stability when putting the pieces together and prevent the prosthesis from unscrewing.

Hexagon

Taper 11°

P

Respects the anatomy n The slight taper of the neck is useful in cases where the crestal bone is very thin and where the mesio-distal spaces are narrow. n Allows for a wider choice of prosthetics. n Eliminates the need, in certain cases, for bone grafting.

Primary stability n Optimisation of the primary stability thanks to the taper of the implant and the adjustment of the compression according to the bone quality. n Threaded to the apex of the implant thus providing good apical anchorage. n Optimal primary anchorage thanks to the slightly tapered microthread with cortical support. n Better distribution of the stress within the bone thanks to the synchronisation between the microthreads, the macrothreads and the protrusions.

Bone level prosthetic joint n More visible and more accessible with the probe. n It can be more easily controlled by the practitioner during sealing and long term care of the implant. n Machined micro-grooves on the neck with a 0.2 Îźm Ra: perfect attachment of the soft tissue thanks to the specific position of the collagen fibers.

*Please contact us for further information about compatibility.

22


Naturall+

n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Technichal features

Ø 3.7 - 4.2 - 4.7 - 5.2 Supracrestal 0.4 mm

Smooth Light conicity «cortical support»

Microthread 2.9 mm

Sandblasted and etched length

Ø 3.5 - 4 - 4.5 - 5

0.25 to 0.40 mm according to the implant Ø

Thread 0.9 mm

Real screw thread 1.80 mm

Double asymmetrical thread

Ø 2.6 - 3 - 3.4 - 3.8

Implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Lenght «L»

Ø 3 mm

Ø 3.5 mm

Ø 4 mm

Ø 4.5 mm

6 mm

-

-

-

NICP 45 060** NICP 50 060** NICP 60 060**

8 mm

NICP 30 080*

NICP 35 080

NICP 40 080

NICP 45 080

NICP 50 080

-

10 mm

NICP 30 100*

NICP 35 100

NICP 40 100

NICP 45 100

NICP 50 100

-

12 mm

NICP 30 120*

NICP 35 120

NICP 40 120

NICP 45 120

NICP 50 120

-

14 mm

NICP 30 140*

NICP 35 140

NICP 40 140

NICP 45 140

NICP 50 140

-

Ø 5 mm

Ø 6 mm

L

* For diameter 3 mm implants: see presentation prosthetic panorama pages 149 - 151. ** For Ø 6 mm implants: panorama p 40 to 47. See presentation of the short implants and the specific surgical kit pages 133 - availability December 2014.

23

I. Direct handling

2

Direct implant driver


2 Naturall+

I. Direct handling

INSTRUMENTATION AND KITS Optional instruments Directional indicators for implant

Gingival gauge Ref. NJP 22 280

Ref. NPG 16 100

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

Ă˜ 2.2 Depth drilling indication

8 mm 10 mm 12 mm 14 mm 16 mm 18 mm

Ă˜ 3.8 Gingival height indication

Removable and autoclavable drill stops to manage the bone density Autoclavable drill stops are supplied in the surgical kit. For each of the 16 drills there is a specific stop which allows the clinician to adjust the size of the implant sockets and the implant compression. The diameter and length is marked on each stop. The stops are used with the final conical drill in the case of medium bone (D3). This system of removable drill stops reduces the number of drills required for the different bone densities encountered.

! !

The length indicated on the stop corresponds to the implant length and not its actual length. The management of the bone density is based on the differentiated use of the final conical drill:

Soft bone D4 > Do not use the final conical drill Medium bone D3 > Drill used with its stop Hard bone D2 > Final conical drill used without stop Very hard bone D1 > Final conical drill used without stop + very hard bone drill

NEW Mini surgical kit This simplified kit includes all the instruments necessary to place Naturall+ implants Ă˜ 3.5 - 4 - 4.5 lengths 8, 10, 12, and 14 mm.

Picture for illustration purpose only

24

Ref. NICKP 35 4X


NICKP 35 4X CONTENTS

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills: Cortical drills:

Terminal conical drills:

Removable stops for terminal conical drills:

Very hard bone drill:

Direct implant key Direct implant mandrel External hexagonal key External hexagonal mandrel Click wrench Depth gauge Drill stop tool Directional indicators for implants

2

n The second plate can be inclined to better see the instruments during the surgery.

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 4 - drill Ø 2.6 for implants Ø 4.5 - drill Ø 3 Ø 3.5 Ø4 Ø 4.5 Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 3.5 Ø4 Ø 4.5 medium - 15 mm short - 20 mm medium - 12 mm short - 22 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 NFB 26 150 NFV 30 150 NFE 35 22 NFE 40 26 NFE 45 30 NFC 35 080 NFC 35 100 NFC 35 120 NFC 35 140 NFC 40 080 NFC 40 100 NFC 40 120 NFC 40 140 NFC 45 080 NFC 45 100 NFC 45 120 NFC 45 140 NBU 35 080 NBU 35 100 NBU 35 120 NBU 35 140 NBU 40 080 NBU 40 100 NBU 40 120 NBU 40 140 NBU 45 080 NBU 45 100 NBU 45 120 NBU 45 140 NFC 35 DO NFC 40 DO NFC 45 DO CCP 35 30 CMP 35 20 CCL HE 12 22 CMA HE 12 22 CCC 120 AJT 22 280 NCB 30 50 NPG 16 100

Pictures for illustration purposes only

25

I. Direct handling

170 mm

Naturall+

n A smaller size to gain space on the sterile field and in the autoclave.

90 mm


2

This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Naturall+ implants Ø 3.5 - 4 - 4.5 - 5.

Naturall+

I. Direct handling

Complete surgical kit

Ref. NICT P0

1

2

3

4

1 - Integrated graduated ruler 2 - Numerical sequences of the instruments for calibrating the implant sockets 3 - Readibility of the sequences step by step presentation indications with arrows 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

CONTENTS NICT P0

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Pictures for illustration purposes only

26

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 4 - drill Ø 2.6 for implants Ø 4.5 - drill Ø 2.6 for implants Ø 4.5 - drill Ø 3 for implants Ø 5 - drill Ø 2.8 for implants Ø 5 - drill Ø 3.4 Ø 3.5 Ø4 Ø 4.5 Ø5

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 NFB 26 150 NFV 26 150 NFV 30 150 NFM 28 150 NFM 34 150 NFE 35 22 NFE 40 26 NFE 45 30 NFE 50 34


Removable stops for terminal conical drills:

Very hard bone drills:

Direct implant keys:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins Ø 3 Depth gauge Drill stop tool Directional indicators for implants

NFC 35 080 NFC 35 100 NFC 35 120 NFC 35 140 NFC 40 080 NFC 40 100 NFC 40 120 NFC 40 140 NFC 45 080 NFC 45 100 NFC 45 120 NFC 45 140 NFC 50 080 NFC 50 100 NFC 50 120 NFC 50 140 NBU 35 080 NBU 35 100 NBU 35 120 NBU 35 140 NBU 40 080 NBU 40 100 NBU 40 120 NBU 40 140 NBU 45 080 NBU 45 100 NBU 45 120 NBU 45 140 NBU 50 080 NBU 50 100 NBU 50 120 NBU 50 140 NFC 35 DO NFC 40 DO NFC 45 DO NFC 50 DO CCP 35 20 CCP 35 30 CCP 35 40 CMP 35 20 CMP 35 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120 NAP 15 22 18 AJT 22 280 NCB 30 50 NPG 16 100

27

I. Direct handling

2

Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 5 - length 8 mm Ø 5 - length 10 mm Ø 5 - length 12 mm Ø 5 - length 14 mm Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 5 - length 8 mm Ø 5 - length 10 mm Ø 5 - length 12 mm Ø 5 - length 14 mm Ø 3.5 Ø4 Ø 4.5 Ø5 short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

Naturall+

Terminal conical drills:


I. Direct handling

teknika

28


I. Direct handling

VE RSATILE I M PL ANT

natea

29


3 Natea+

I. Direct handling

natea

VERSATILE IMPLANT

The Natea+ is a “universal” implant, very easy to insert, that can be used to treat most clinical cases, in particular with short 6 mm implants and large diameter implants (6 mm). For users of Aesthetica+² and Straumann® implants there is an interesting additional range for the aesthetic sector, thanks to its straight neck from 3.7 mm and its emergence switching. Its dimensions and slightly supracrestal positioning is suitable for most clinical cases, and helps produce a lasting aesthetic result (location and control of the prosthetic joint).

Hexagon

A unique connection

Taper 11°

P

n Unique connection for all implant diameters and the 4 platforms = simplified management of prosthetic parts between the dental office and the lab. n Connection compatible* with the Astra® (Ocean platform), Naturactis and Naturall+ prosthetic ranges. n Tapered internal connection (Morse Taper) guarantees the airtightness of the prosthetic joint and the stability of the abutment-implant connection (S.Dibart, M. Warbington, M. Fan Su, Z. Skobe). n The connection has an internal hexagon which allows the abutment to be orientated at the right angle. n The significant depth of the connection and the quality of the adjustments garantee good stability when putting the pieces together and prevent the prosthesis from unscrewing.

Primary stability n Threaded to the apex of the implant thus providing good apical anchorage. n Optimal primary anchorage thanks to the slightly tapered microthread with cortical support. n Better distribution of the stress within the bone thanks to the synchronisation between the microthreads, the macrothreads and the protrusions. n The central protrusion between the threads increases the bone/implant contact surface area by 15%. Photo credit: Dr SERCKI (France)

Bone level prosthetic joint n More visible and more accessible with the probe. n It can be more easily controlled by the practitioner during sealing and long term care of the implant. n Machined micro-grooves on the neck with a 0.2 μm Ra: perfect attachment of the soft tissue thanks to the specific position of the collagen fibers.

*Please contact us for further information about compatibility.

30


Natea+

3

n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Technichal features

Ø 3.7 - 4.2 - 4.9 - 6.2 Supracrestal 0,4 mm

Smooth

Sandblasted and etched length

Light conicity «cortical support»

Microthread 2.9 mm

Thread features

0.3 mm

Thread 0.8 mm

Real screw thread 1.60 mm

7° 0.08 mm 40°

Double asymmetrical thread

0.3 mm

Thread 0.8 mm

Real screw thread 1.6 mm

Ø 3.6 - 4.1 - 4.8 - 6

Implant references

T60 grade IV pure titanium. Implants are supplied with a cover screw.

Lenght «L»

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 6 mm

6 mm

-

NIDP 41 42 060*

NIDP 48 49 060*

NIDP 60 62 060*

8 mm

NIDP 36 37 080

NIDP 41 42 080

NIDP 48 49 080

NIDP 60 62 080

10 mm

NIDP 36 37 100

NIDP 41 42 100

NIDP 48 49 100

NIDP 60 62 100

12 mm

NIDP 36 37 120

NIDP 41 42 120

NIDP 48 49 120

NIDP 60 62 120

14 mm

NIDP 36 37 140

NIDP 41 42 140

NIDP 48 49 140

L

* For Ø 6 mm implants: see presentation of the short implants and the specific surgical kit pages 134 - 135.

31

I. Direct handling

Direct implant driver


3

Optional instruments Directional indicators for implant

Natea+

I. Direct handling

INSTRUMENTATION AND KITS

Gingival gauge Ref. NJP 22 280

Ref. NPG 16 100

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm

Ø 2.2 Depth drilling indication

8 mm 10 mm 12 mm 14 mm 16 mm 18 mm

Ø 3.8 Gingival height indication

Taps 35 mm

6 mm 8 mm 10 mm 12 mm 14 mm

For implants

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 6 mm

Ref. taps

ATB 36 126

ATR 41 126

ATV 48 126

ATJ 60 120

n Colour coded. n Manuel use with the square key (ref. CEC 40) see page 158.

Removable and autoclavable drill stops to manage the drilling depth The surgical kits include a series of drill stops for each implant diameter. Drill stops are easily placed and removed from the drill and allow the dentist to work confidently above nerves and below the sinuses.

1. Stop setting Stop Stop 2. Stop in correct position STOP Dental nerve

32


Mini surgical kit

Natea+

Ref. NIDKP 36 4X

This simplified kit includes all the instruments necessary to place Natea+ implants Ø 3.6 - 4.1 - 4.8 lengths 8, 10, 12, 14 mm.

90 mm

170 mm

n A smaller size to gain space on the sterile field and in the autoclave.

CONTENTS NIDKP 36 4X

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Terminal drills: Direct implant key Direct implant mandrel External hexagonal driver External hexagonal mandrel Click wrench Depth gauge Directional indicators for implants

n The second plate can be inclined to better see the instruments during the surgery.

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.6 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 Ø 3.6 Ø 4.1 Ø 4.8 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 medium - 15 mm short - 20 mm medium - 12 mm short - 22 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 ANFP 36 30 ANFP 42 35 ANFP 48 42 AFD 38 160 AFD 45 160 CCP 35 30 CMP 35 20 CCL HE 12 22 CMA HE 12 22 CCC 120 AJT 22 280 NPG 16 100

Pictures for illustration purposes only

33

I. Direct handling

3

NEW


3

These surgical kits provide all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Natea+ implants.

Additional empty spaces to insert the 3 keys and the 2 direct implant mandrels required to place the implants Aesthetica+² or Uneva+.

Natea+

«EXPERT 60» Natea+ kit

Contents instruments for Natea+ implants Ø 3.6 to 6

Ref. NIDT P6

«EXPERT» Natea+ kit

Contents instruments for Natea+ implants Ø 3.6 to 4.8

Ref. NIDT P0 1

2

3

4

Ref. NIDT P6

I. Direct handling

Complete surgical kits

1 - Integrated graduated ruler 2 - Readibility of the sequences step by step presentation indications with arrows 3 - Gripping of the stops directly with the contra-angle 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

CONTENTS Point drill Initial drills Ø 2.2: NIDT P6

Pictures for illustration purposes only

34

Ø 1.5 - 2.2 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm

CFP 15 22 50 AFI 22 060 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140


Cortical drills:

Hard bone drills:

Removable stops:

Direct implant keys:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins: Initial depth gauge Depth gauges:

Drill stop tool Directional indicators for implants

AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AFD 48 120 AFD 52 120 AFJ 54 120 ANFP 36 30 ANFP 42 35 ANFP 48 42 ANFP 60 52 AFD 36 160 AFD 38 160 AFD 45 160 AFD 57 120 ABU 30 060 ABU 30 080 ABU 30 100 ABU 30 120 ABU 30 140 ABU 35 060 ABU 35 080 ABU 35 100 ABU 35 120 ABU 35 140 ABU 42 060 ABU 42 080 ABU 42 100 ABU 42 120 ABU 42 140 NHB 60 060 NHB 60 080 NHB 60 100 CCP 35 20 CCP 35 30 CCP 35 40 CMP 35 20 CMP 35 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120

Ø3 Ø 4.8

NAP 15 22 18 AAP 48 22 28 AJT 22 280

Ø 3.6 Ø 4.1 Ø 4.8

AJB 30 280 AJR 35 280 AJV 42 280 ACB 36 48 NPG 16 100

35

I. Direct handling

AFD 28 160

3

for implants Ø 3.6 - drill Ø 2.6 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 6 - drill Ø 4.8 for implants Ø 6 - drill Ø 5.2 for implants Ø 6 - drill Ø 5.4 Ø 3.6 Ø 4.1 Ø 4.8 Ø6 for implants Ø 3.6 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 for implants Ø 6 - drill Ø 5.7 for drills Ø 2.8 and 3 - length 6 mm for drills Ø 2.8 and 3 - length 8 mm for drills Ø 2.8 and 3 - length 10 mm for drills Ø 2.8 and 3 - length 12 mm for drills Ø 2.8 and 3 - length 14 mm for drills Ø 3.3 and 3.5 - length 6 mm for drills Ø 3.3 and 3.5 - length 8 mm for drills Ø 3.3 and 3.5 - length 10 mm for drills Ø 3.3 and 3.5 - length 12 mm for drills Ø 3.3 and 3.5 - length 14 mm for drills Ø 3.8/4/4.2/4.5 - length 6 mm for drills Ø 3.8/4/4.2/4.5 - length 8 mm for drills Ø 3.8/4/4.2/4.5 - length 10 mm for drills Ø 3.8/4/4.2/4.5 - length 12 mm for drills Ø 3.8/4/4.2/4.5 - length 14 mm for drills Ø 4.8/5.2/5.4/5.7 - length 6 mm for drills Ø 4.8/5.2/5.4/5.7 - length 8 mm for drills Ø 4.8/5.2/5.4/5.7 - length 10 mm short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

Natea+

Intermediary cylindrical drills:


3

This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Natea+, Uneva and Unevane implants Ø 3.6 or 4.1 in guided surgery.

Natea+

I. Direct handling

Guided surgery kit

Ref. UGCT 00

1

2

1 - Numerical sequences of the instruments for calibrating the implant sockets 2 - Readibility of the sequences step by step presentation indications with arrows 3 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

UGCT 00 CONTENTS

Drill Ø 1.5 for needle placement Positioning needle Drilling guides:

Gingival trepans: Gingival cutters: Drills Ø 2.2:

Pictures for illustration purposes only

36

3

UGC FA 15 200 CGC AA 15 280

Ø 2.2 Ø 2.8 Ø3 Ø 3.3 Ø 3.5 Ø 3.8 Ø4 Ø 4.2 RP Ø 4.1 WP Ø 4.8 RP Ø 4.1 WP Ø 4.8 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm

UGC GP 22 UGC GP 28 UGC GP 30 UGC GP 33 UGC GP 35 UGC GP 38 UGC GP 40 UGC GP 42 TCG 41 49 TCG 48 54 DGCG 41 DGCG 48 NFI 22 145 NFI 22 165 NFI 22 185 NFI 22 205 NFI 22 225


Cortical drills:

Taps:

Stops for cylindrical drills:

Stops for gingival and cortical drills:

Direct implant keys - Natea+: Direct implant mandrels - Natea+: Implant-holders: Implant-holder key Implant-holder mandrel External hexagonal keys: External hexagonal mandrel Click wrench Setting key for implant-holder cover end Counter torque key 4 mm square key for taps Drill stop tool

NFD 28 225 NFB 30 185 NFB 30 225 NFD 33 185 NFD 33 225 NFD 33 185 NFD 33 225 NFR 35 185 NFR 35 225 NFD 38 185 NFD 38 225 NFD 40 185 NFD 40 225 NFV 42 185 NFV 42 225 NFD 45 185 NFD 45 225 UFE 36 30 UFE 41 30 UFE 41 35 UFE 49 42 06 UET 36 225 UET 41 225 UET 48 225 NHB 45 060 NHB 45 080 NHB 45 100 NHB 45 120 UGC BU RP 085 UGC BU RP 105 UGC BU WP 085 UGC BU WP 105 CMP CG 35 CMP CG 35 CCP CG 35 CCP CG 35 UGC PI UHD 36 L UGC PI UHD 48 L CPI 170 CMI 230 CCL HE 12 18 CCL HE 12 22 CMA HE 12 22 CCC 120 CCA CPI CAR 30 78 CEC 40 CB CG 00

37

I. Direct handling

NFD 28 185

3

for implants Ø 3.6 - drill Ø 2.8 - short for implants Ø 3.6 - drill Ø 2.8 - long for implants Ø 3.6 - drill Ø 3 - short for implants Ø 3.6 - drill Ø 3 - long for implants Ø 3.6 - drill Ø 3.3 - short for implants Ø 3.6 - drill Ø 3.3 - long for implants Ø 4.1 - drill Ø 3.3 - short for implants Ø 4.1 - drill Ø 3.3 - long for implants Ø 4.1 - drill Ø 3.5 - short for implants Ø 4.1 - drill Ø 3.5 - long for implants Ø 4.1 - drill Ø 3.8 - short for implants Ø 4.1 - drill Ø 3.8 - long for implants Ø 4.8 - drill Ø 4 - short for implants Ø 4.8 - drill Ø 4 - long for implants Ø 4.8 - drill Ø 4.2 - short for implants Ø 4.8 - drill Ø 4.2 - long for implants Ø 4.8 - drill Ø 4.5 - short for implants Ø 4.8 - drill Ø 4.5 - long RP Ø 3.6 - Natea RP Ø 3.6 - Uneva RP Ø 4.1 WP Ø 4.8 Ø 3.6 Ø 4.1 Ø 4.8 length 6 mm length 8 mm length 10 mm length 12 mm RP RP+2 WP WP+2 RP WP RP WP long RP long WP short - 7 mm short - 23 mm short - 8 mm medium - 12 mm short - 22 mm

Natea+

Final drills:


1 2 3 Naturactis, Naturall+ & Natea+

x

x

x

- Plural

x

x

- Complete

x

x

teknikalab customized abutment

- Single

Angulated trans-screwed abutment

25

Straight trans-screwed abutment

25

Solid abutment

Temporary non-rotational abutment

10

FINAL RESTORATION

Temporary rotational abutment

Direct temporary abutment

TEMPORARY RESTORATION

Healing abutment

I. Direct handling

Prosthetic recommendations

25

35

25

25

25

x

x

x

x

x

x1

x

x

x

x

1

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

Tightening torque (N.cm) - Abutment

IV. Narrow implants

- Screwed prosthesis Restorations

Prosthesis - Cemented

x

- Trans-screwed/cemented - Screwed - Overdenture Materials - Zirconia - Titanium

x

x

x

- Gold alloy

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

38


Non-rotational Esthetibase

Rotational Esthetibase

ConHex abutment

Straight Tetra abutment

Angulated Tetra abutment

Straight Plural abutment

Angulated Plural abutment

O'Ring abutment

25 25 25 35 35 25 35 25 25

x x

(x)1 x x x x x x

x x x x x x

x

x

x

x

x x

x

x

x

x

x

x

x

x

x2

x2

x

x 20 20 20 25 20

x

x

x

x

x

x

x x

x

IV. Narrow implants

Customizable abutment

25

x

x

39

3

2 I. Direct handling

Naturactis, Naturall+ & Natea+

Gold palladium abutment

FINAL RESTORATION

1


1 2 3

Cemented prosthesis on trans-screwed abutment

1

HEALING ABUTMENTS 10 N.cm

TEMPORIZATION

natea naturall

ep

h (mm)

h (mm)

1

ø 3.6

ø 4.6

ø 5.2

NCI 36 23

NCI 46 23

NCI 52 23

------

1

NCI 36 34

NCI 46 34

NCI 52 34

NCI 60 34*

3

2

NCI 36 45

NCI 46 45

NCI 52 45

NCI 60 45

4

3

NCI 36 56

NCI 46 56

NCI 52 56

NCI 60 56

5

4

NCI 36 67

NCI 46 67

NCI 52 67

NCI 60 67

Ø 3.7 mm

1.5 mm Healing abutment and final abutment height correspondence

Ø 4.1 mm

POP-UP IMPRESSION COPING 10 N.cm

Supplied with a titanium fixing screw (ref. NPS VTB 16 156)

Supplied with a fixing screw (ref. NPS VTB 16 174) Supplied with an impression cap for pick-up technique (ref. APS TCP 36 40)

NPI 37

NPU 35

SCANBODY DIRECT ON IMPLANT

PICK-UP IMPRESSION COPINGS 10 N.cm Supplied with a fixing screw

Plastic Supplied with a fixing screw (ref. NPS VG 16 156)

Reference

Short

Long

Impression coping NPE T35 Fixing screw

NPE T35 L

NPS VG 16 200 NPS VG 16 250

STRAIGHT ABUTMENTS 25 N.cm - Supplied with a titanium fixing screw (Ref. NVP 35)

natea naturall

ep

ø 3.6

h (mm)

1

FINAL RESTORATION

h

1

ø 5.2

ø 4.6

* Do not use with Naturactis

ø6

NPS PD 36 06

NPS PD 46 06

NPS PD 52 06

------

NPS PD 36 16

NPS PD 46 16

NPS PD 52 16

NPS PD 60 16*

3

2

NPS PD 36 26

NPS PD 46 26

NPS PD 52 26

NPS PD 60 26

4

3

NPS PD 36 36

NPS PD 46 36

NPS PD 52 36

NPS PD 60 36

5

4

NPS PD 36 46

NPS PD 46 46

NPS PD 52 46

NPS PD 60 46

GOLD PALLADIUM ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. NVP VPA 35)

natea naturall h (mm)

h (mm) NPS PS 46 06

2 1 NPS PS 46 16 h : supracrestal height (mm)

h

natea naturall

Ht (mm)

1 2

h (mm) 2

h (mm) 1

h : supracrestal height (mm)

Ø 6 mm

CAD-CAM CUSTOMIZED ABUTMENT

Single-unit Multi-unit prosthesis prosthesis (non-rotational) (rotational) NPC PTO 40 16 NPC PTC 40 16

NPS PAT 60 16

h : supracrestal height (mm)

4,65 mm

NPC PTO 40 06 NPC PTC 40 06 1

h : supracrestal height (mm)

h

Size S - Supplied with a titanium fixing screw (ref. NVP VPA 35)

Ht (mm)

Ø

Supplied with a titanium fixing screw (ref. NVP 35)

ESTHETIBASE ABUTMENTS FOR ZIRCONIA PROSTHESIS 25 N.cm

natea naturall

h

CUSTOMIZABLE ABUTMENT 25 N.cm

Ø 4.6 mm

Gold + burn-out

1

Suppl translu rotatio (ref. APS an op non-ro (ref. APS

NPS P

POP-IN IMPRESSION COPING

2

40

Ø

* Do not use with Naturactis

h (mm)

IV. Narrow implants

h

2

ETK NA 35 SB

3

ø6

13.5 mm

IMPRESSION

2

DIRE ABU

10 mm

Naturactis, Naturall+ & Natea+

Prise I. Direct directe handling

A complete prosthetic range

Ø 4 mm

Customized to your case and made by our CADCAM center Supplied with a fixing screw (ref. NVP 35)


utment

nt height dence

TEMPORARY NON-ROTATIONAL ABUTMENT 25 N.cm

Supplied with a translucent white rotational cap (ref. APS CP 36 40) and an opaque white non-rotational cap (ref. APS CO 36 40) NPS PPT 36 40

Supplied with a titanium fixing screw (ref. NVP 35)

natea naturall Ø 3.6 mm

h (mm)

h (mm)

2

1

Ø 3.8 mm

h NPS PPT 38 2

TEMPORARY ROTATIONAL ABUTMENT 25 N.cm

Ø 3.8 mm

Supplied with a titanium fixing screw (ref. NVP 35)

natea naturall h (mm)

h (mm)

2

1

h NPS PPTR 38 2

LABORATORY GUIDE SCREWS

NLA H35

20 mm

16 mm

Can be cut

Short

Medium

Long

NPS VG 16 156

NPS VG 16 200

NPS VG 16 250 16 mm

9 mm

BITE REGISTRATION ABUTMENT (TEST ABUTMENT)

14 mm

For straight, angulated and customizable abutments

For gold palladium and Esthetibase abutments

ETK NA 35 PO

26 mm

Ø 3.5 mm

IMPLANT ANALOG

I. Direct handling

1 2 3 DIRECT TEMPORARY ABUTMENT 25 N.cm

Naturactis, Naturall+ & Natea+

Cemented prosthesis on trans-screwed abutment

NPS VG 16 160

7° ANGULATED ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. NVP 35)

natea naturall h (mm)

h (mm)

1 2

ep ø 3.6 ------

1

Ø ø 4.6

ø 5.2

NPS PA 46 07 1 NPS PA 52 07 1

ø6

------

h

NPS PA 36 07 2 NPS PA 46 07 2 NPS PA 52 07 2 NPS PA 60 07 2

3

2

NPS PA 36 07 3 NPS PA 46 07 3 NPS PA 52 07 3 NPS PA 60 07 3

4

3

NPS PA 36 07 4 NPS PA 46 07 4 NPS PA 52 07 4 NPS PA 60 07 4

IV. Narrow implants

o not with uractis

h : supracrestal height (mm)

15° ANGULATED ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. NVP 35)

natea naturall h

h (mm)

Ø

ep

h (mm)

1 2

ø 3.6

-----1

ø 4.6

ø 5.2

NPS PA 46 15 1 NPS PA 52 15 1

ø6

------

h

NPS PA 36 15 2 NPS PA 46 15 2 NPS PA 52 15 2 NPS PA 60 15 2

3

2

NPS PA 36 15 3 NPS PA 46 15 3 NPS PA 52 15 3 NPS PA 60 15 3

4

3

NPS PA 36 15 4 NPS PA 46 15 4 NPS PA 52 15 4 NPS PA 60 15 4

h : supracrestal height (mm)

20° ANGULATED ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. NVP 35)

natea naturall h (mm)

Ø

ep ø 3.6

1 2

ø 4.6

ø 5.2

ø6

h (mm) -----1

NPS PA 46 20 1 NPS PA 52 20 1

------

NPS PA 36 20 2 NPS PA 46 20 2 NPS PA 52 20 2 NPS PA 60 20 2

3

2

NPS PA 36 20 3 NPS PA 46 20 3 NPS PA 52 20 3 NPS PA 60 20 3

4

3

NPS PA 36 20 4 NPS PA 46 20 4 NPS PA 52 20 4 NPS PA 60 20 4

h

h : supracrestal height (mm)

41


1 2 3

Cemented prosthesis on solid abutment

Naturactis, Naturall+ & Natea+

Ø

1

H

SOLID ABUTMENTS 35 N.cm

TEMPORIZATION

I. Direct handling

A complete prosthetic range - continuation

h

natea naturall

Ø 3.6

h (mm) 1

h (mm)

2

1

Ø 4.8

H 4 mm

H 5.5 mm

Ø 6.5

H 4 mm

H 5.5 mm

H 7 mm

H 4 mm

NPS PP 36 40 1 NPS PP 36 55 1 NPS PP 48 40 1 NPS PP 48 55 1 NPS PP 48 70 1

H 5.5 mm

------

------

NPS PP 36 40 2 NPS PP 36 55 2 NPS PP 48 40 2 NPS PP 48 55 2 NPS PP 48 70 2 NPS PP 65 40 2 NPS PP 65 55 2

3

2

NPS PP 36 40 3 NPS PP 36 55 3 NPS PP 48 40 3 NPS PP 48 55 3 NPS PP 48 70 3 NPS PP 65 40 3 NPS PP 65 55 3

4

3

NPS PP 36 40 4 NPS PP 36 55 4 NPS PP 48 40 4 NPS PP 48 55 4 NPS PP 48 70 4 NPS PP 65 40 4 NPS PP 65 55 4

5

4

NPS PP 36 40 5 NPS PP 36 55 5 NPS PP 48 40 5 NPS PP 48 55 5 NPS PP 48 70 5 NPS PP 65 40 5 NPS PP 65 55 5

h : supracrestal height (mm)

PROTECTION CAPS Ø 3.6

2

Ø 4.8

H 4 mm

H 5.5 mm

H 4 mm

H 5.5 mm

H 7 mm

H 4 mm

H 5.5 mm

APS CP 36 40

APS CP 36 55

APS CP 48 40

APS CP 48 55

APS CP 48 70

APS CP 65 40

APS CP 65 55

H 4 mm

IMPRESSION

Ø

SNAP-ON IMPRESSION COPINGS Ø 3.6

IV. Narrow implants

H +2 mm

Ø 6.5

Ø 4.8 H 5.5 mm

Ø 6.5

H 4 mm

H 5.5 mm

H 7 mm

H 4 mm

H 5.5 mm Ø

APS TCP 36 40 APS TCP 36 55 APS TCP 48 40 APS TCP 48 55 APS TCP 48 70 APS TCP 65 40 APS TCP 65 55 Different colors according to the version

SNAP-ON OPEN IMPRESSION COPINGS for adjusted abutments Ø 3.6

Ø 4.8

Ø 6.5

APS TCP 36

APS TCP 48

APS TCP 65

Ø

Ø H

SOLID ABUTMENT ANALOGS Ø 3.6 H 4 mm

Ø 4.8 H 5.5 mm

Ø 6.5

H 4 mm

APS H 36 40 APS H 36 55 APS H 48 40 Different colors according to the version

FINAL RESTORATION

3

H 5.5 mm

H 7 mm

H 4 mm

H 5.5 mm

APS H 48 55

APS H 48 70

APS H 65 40

APS H 65 55

BURN-OUT SLEEVES Ø 3.6 Ø 4.8 Ø 6.5 H 10 mm 10 mm 7 mm Non-rotational basis for APS BCO 36 100 APS BCO 48 100 APS BCO 65 70 single-unit prosthesis Rotational basis for multi-unit prosthesis

APS BCC 36 100

APS BCC 48 100

H

H

Ø

Ø

APS BCC 65 70

KITS Ø 3.6 H 4 mm

Ø 4.8

Ø 6.5

H 5.5 mm

H 4 mm

H 5.5 mm

H 7 mm

H 4 mm

H 5.5 mm

Single-unit prosthesis NPS KIT E04

NPS KIT E05

NPS KIT N04

NPS KIT N05

NPS KIT N07

NPS KIT W04

NPS KIT W05

Multi-unit prosthesis NPS KIT EC4

NPS KIT EC5

NPS KIT NC4

NPS KIT NC5

NPS KIT NC7

NPS KIT WC4 NPS KIT WC5

Supplied without abutment. A kit contains a protection cap, a snap-on impression coping, a snap-on open impression coping, an analog and a burn-out sleeve. Specify the abutment height and the prosthesis type (single-unit or multi-unit).

42


tal m)

on ConHex abutment

TEMPORARY CAPS

CONHEX ABUTMENTS 35 N.cm

natea naturall h (mm)

25°

Ø 3.5 mm

Ø 3.5 mm h (mm)

1

NPV PI 35 23

2

1

NPV PI 35 34

3

2

NPV PI 35 45

1.7 mm h

3.5 mm

h : supracrestal height (mm)

Supplied with a titanium fixing screw (ref. NVP 30)

5.6 mm

Plastic

Titanium 10 N.cm

NPV CP 3X

NPV CPC 35

I. Direct handling

1 2 3 Naturactis, Naturall+ & Natea+

2.15 mm h

Screwed prosthesis

mm

8 mm

m

Supplied with a titanium fixing screw (ref. NPV VG 14 105)

POP-IN IMPRESSION COPING 10 N.cm 10.5 mm

Supplied with a titanium fixing screw (ref. NPV VG 14 105)

NPV TC 3X

CONHEX ABUTMENT ANALOG

Plastic Supplied with a fixing screw (ref. NVP 30) ETK NX 30 SB

TITANIUM NITRURED ABUTMENT 20 N.cm Can be shaped but not cut until the circular groove

8.5 mm

1.2 mm

NPS PD 40 12

Ø 3.6 mm

NPI 30

SCANBODY ON CONICAL ABUTMENT

Supplied with a fixing screw (réf. NVP 30)

11.5 mm

Ø 3.6 mm

IV. Narrow implants

PICK-UP IMPRESSION COPING 10 N.cm

Ø 3.8 mm

Can be cut

LABORATORY GUIDE SCREW

NPV HC 3X

NPV VG 14 105

12 mm

GOLD PALLADIUM ABUTMENTS 20 N.cm Supplied with a titanium fixing screw (ref. NVP 30)

10 mm

Hexagonal

1.5 mm

Cylindrical

NPS BSH 40 100 NPS BSR 40 100

Ø 4 mm

ESTHETIBASE ABUTMENTS FOR ZIRCONIA PROSTHESIS 25 N.cm Size S - Supplied with a titanium fixing screw (ref. NVP VP 30) Single-unit prosthesis (non-rotational) NPC PTO 3 X

Multi-unit prosthesis (rotational) NPC PTC 3 X

4,65 mm

Ø 4 mm

43


1 2 3

Screwed prosthesis

Naturactis, Naturall+ & Natea+

on Plural straight abutment

1

TEMPORIZATION

I. Direct handling

A complete prosthetic range - continuation

PLURAL STRAIGHT ABUTMENTS 35 N.cm

TEMPORARY CAP 10 N.cm

natea naturall

Titanium

h (mm)

Ø 3.8 mm h (mm)

1

Ø 4.8 mm 2.5 mm

NPV CPP 38 32

80° NPV PP 31 07

2

1

NPV PP 31 18

3

2

NPV PP 31 28

4

3

NPV PP 31 38

h

5 4 NPV PP 31 48 h : supracrestal height (mm)

TEMPORARY ABUTMENT 20 N.cm Supplied with a titanium fixing screw (ref. NPV VP 18 56)

10 mm 1 mm

NPV PPT 46 100

2

Ø 4.7 mm

SCANBODY ON CONICAL ABUTMENT

PICK-UP IMPRESSION COPING

Plastic Supplied with a fixing screw (ref. NPV VP 18 56)

IV. Narrow implants

IMPRESSION

Supplied with a titanium fixing screw (ref. NPV VG 18 105) NPV TP 4X

Ø 4.6 mm

ETK NA SPD

Ø 3.8 mm

Ø 3.8 mm

PLURAL STRAIGHT ABUTMENT ANALOG

LABORATORY GUIDE SCREW

Can be cut NPV HP 4X

14.5 mm

NPV VG 18 105

FINAL RESTORATION

3

44

BURN-OUT SLEEVES 20 N.cm Unscrewing treatment Supplied with a titanium fixing screw (ref. NPV VP 18 56) Ø 4.6 mm

Ø 5.1mm

NPV CCP 35 46

NPV CCP 4X 51

12 mm 1 mm Ø


17° PLURAL ANGULATED ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. NVP VPA 35) Supplied with a reusable titanium implant-holder

natea naturall

TEMPORARY CAP 10 N.cm Ø 4.05 mm

Supplied gamma sterilized

h (mm)

h (mm)

2

1

NPV PPA 35 17 20

3

2

NPV PPA 35 17 30

4

3

NPV PPA 35 17 40

NPV CPA 38 24

4 mm

h

30° PLURAL ANGULATED ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. NVP VPA 35) Supplied with a reusable titanium implant-holder

natea naturall

TEMPORARY ABUTMENT 20 N.cm Supplied with a titanium fixing screw (ref. NPV VPA 14 40)

h (mm)

h (mm)

3

2

NPV PPA 35 30 30

4

3

NPV PPA 35 30 40

11 mm

NPV TPPA 38

1 mm

I. Direct handling

1 2 3 on Plural angulated abutment

Ø 4.1 mm

h : supracrestal height (mm)

PICK-UP IMPRESSION COPING 10 N.cm Supplied with a titanium fixing screw (ref. NPV VPA 14 150)

SCANBODY ON CONICAL ABUTMENT

10 mm

NPV TPA 38

Plastic Supplied with a fixing screw (ref. NPV VPA 14 40) ETK NA SPA

Ø 4 mm

IV. Narrow implants

m

Naturactis, Naturall+ & Natea+

mm

Screwed prosthesis

Ø 3.8 mm

LABORATORY GUIDE SCREWS

PLURAL ANGULATED ABUTMENT ANALOG Can be cut

Short

Long

NPV HPA 38

NPV VPA 14 40

NPV VPA 14 150

BURN-OUT SLEEVE 20 N.cm

GOLD PALLADIUM ABUTMENT 20 N.cm

Supplied with a titanium fixing screw (ref. NPV VPA 14 40) NPV CCPA 38

11 mm 1.5 mm Ø 4 mm

Supplied with a titanium fixing screw (ref. NPV VPA 14 40) NPV BSPA 38

10 mm 1.5 mm Ø 4.6 mm

45


1 2 3

Screwed prosthesis

Naturactis, Naturall+ & Natea+

on Tetra abutment 17° ANGULATED ABUTMENTS 25 N.cm

STRAIGHT ABUTMENTS 35 N.cm

Supplied with a reusable stainless steel implant-holder

TEMPORIZATION

Supplied with a single use plastic implant-holder For the straight abutments screwing, use the internal hexagonal key (ref. CCL HI 20 24) or the internal hexagonal mandrel (ref. UMA HI 20 26)

natea naturall h (mm)

h (mm)

1

Ø 4.8 mm

NPV PT 48 1

2

1

NPV PT 48 2

3

2

NPV PT 48 3

4

3

NPV PT 48 4

5

4

NPV PP 48 5

10 N.cm

UPV CPT 48 40

NPV PTA 48 17 25

4

3

NPV PTA 48 17 35

5

4

natea naturall

Ø 4.8 mm

Long

h (mm) 2

C 2.15 mm h

NPV PTA 48 17 45

Supplied with a reusable stainless steel implant-holder

2.15 mm h

PROTECTION CAPS

UPV CPT 48 20

h (mm) 3

Supplied with a fixing screw (ref. NVP VPA 35)

30° ANGULATED ABUTMENTS 25 N.cm

h : supracrestal height (mm)

Short

natea naturall

h : supracrestal height (mm)

h (mm)

h (mm)

4

3

NPV PTA 48 30 35

5

4

NPV PTA 48 30 45

h

TEMPORARY ABUTMENT

11 mm

20 N.cm

2 mm

Supplied with a titanium fixing screw (ref. UPV VMD 14 38)

4 mm

Ø 4.8 mm

UPV PMT 48 110

2

Ø 4.8 mm

UPV TM 48

POP-IN IMPRESSION COPING

Ø 4.8 mm

UPV PI 48

Ø 4.8 mm

Can be cut

S fi

UPV HM 48

N

LABORATORY GUIDE SCREWS

SCANBODY ON CONICAL ABUTMENT Plastic Supplied with a fixing screw (ref. NPV VG 14 105)

P C

ABUTMENT ANALOG

Short

UPV VGM 14 40

Medium

UPV VGM 14 150

15 mm

Supplied with a fixing screw (réf. UPV VGM 14 150)

8 mm

10 mm

4 mm

IMPRESSION

PICK-UP IMPRESSION COPING 10 N.cm

Handle + UPV VGM 14 200 long screw

ETK UN SPB

3

46

n

h

21 mm

1

FINAL RESTORATION

I. Direct handling

A complete prosthetic range - continuation

GOLD PALLADIUM ABUTMENT

BURN-OUT SLEEVE 20 N.cm Unscrewing treatment Supplied with a titanium fixing screw (ref. UPV VMD 14 38) UPV CMC 48 110

20 N.cm 11 mm Ø 4.8 mm

Supplied with a titanium fixing screw (ref. UPV VMD 14 38) UPV BST 48 110

10 mm 1.5 mm Ø 4.8 mm


on O’Ring abutment

TEMPORIZATION

1

1

Ø 5.2 mm

O’RING ABUTMENTS 25 N.cm

2 mm

natea naturall

With O’Ring

Sold single

Ø 2.9 mm

h (mm)

h (mm)

2

1

NPA OR 35 29

NPA OR 35 29 MALE

4

3

NPA OR 35 40

NPA OR 35 40 MALE

6

5

NPA OR 35 60

NPA OR 35 60 MALE

h

h : supracrestal height (mm)

2 13.5 mm

PICK-UP IMPRESSION COPINGS 10 N.cm

Short

Long

Impression coping NPE T35

NPE T35 L

NPS VG 16 200 NPS VG 16 250

IMPRESSION

natea natural

2 Ø 3.5 mm

Ø 4.1 mm

POP-UP IMPRESSION COPING 10 N.cm

SOLID

Supplied with a fixing screw (ref. NPS VTB 16 174) Supplied with an impression cap for pick-up technique (ref. APS TCP 36 40)

NLA H35 Ø 2.5 mm

O’RING ABUTMENT ANALOG

Ø 3.7 mm

POP-IN IMPRESSION COPING

h : supr

PROTE Ø 3.6

H 4 mm

APS CP

SN

APS TCP Differen

SNAPØ 3.6

APS TC

Ø 3.6

NPS VG 16 156

Medium

NPS VG 16 200

Long

NPS VG 16 250

3 FINAL RESTORATION

Short

APS H 3 Differen 26 mm

16 mm

LABORATORY GUIDE SCREWS

20 mm

H 4 mm

NPI 37

FINAL RESTORATION

4 5

SOLID

OPS HOBI

Supplied with a titanium fixing screw (ref. NPS VTB 16 156)

3

2 3

H 4 mm

Can be cut

NPU 35

h (mm) 1

Ø 3.6

IMPLANT ANALOG

IMPRESSION

Fixing screw

10 mm

Supplied with a fixing screw Reference

I. Direct handling

1 2 3 TEMPORIZATION Naturactis, Naturall+ & Natea+

Overdenture

Ø 5.2 mm

O’RING

2 mm

UPA FOR 52 Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

BU

H Non-rota single-un

Rotation multi-un

KITS

Single-u

Multi-un

Supplied burn-out

47


I. Direct handling

teknika

48


I. Direct handling

TISSU E LEVE L I M PL ANT

aesthetica

2

49


TISSUE LEVEL IMPLANT

4

2

The Aesthetica+2 is a one-stage tissue level implant. It is particularly suitable for “recovering” the bone level of a longterm edentulous area or to manage the platform profile for restorations in the posterior part of the mouth. In addition, its 3 platforms can be adapted to all clinical situations.

Aesthetica+2

I. Direct handling

aesthetica

Reliable & user-friendly internal connection n The combination of the Morse taper and the octagonal connection provides stability, and an accurate, reproducible fit at the desired angle. n The insertion depth of the abutment is up to 3.65 mm. n The connection is compatible* with Straumann® dental implant systems (RP and WP).

Taper 8°

Octagon dimension 3.10 mm

3.65 mm

Morse taper

Thread Ø 2

Straumann® compatibility* n Octagonal internal connection (Morse taper). n Compatible* with the Straumann® prosthetics range (RP and WP) which increases the choices available.

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

*Please contact us for further information about compatibility.

50


4

Necks Ø 4.2 - Ø 4.8 - Ø 6.5

Aesthetica+2

Smooth & etched neck 1.3 mm

Sandblasted and etched length

Microthread 2.3 mm

Thread features

Double asymetrical thread

7° 0.08 mm 40°

0.3 mm

Thread 0.8 mm

Real screw thread 1.6 mm

Conical apical profile makes for easier placement Implants Ø 3.6 - Ø 4.1 - Ø 4.8

Implant references Ø neck

T60 grade IV pure titanium. Implants are supplied with a 3 mm in height healing abutment.

L

Ø implant

Lenght «L»

Ø 3.6 mm

Ø 4.1 mm

Neck Ø 4.2 mm

Neck Ø 4.8 mm

6 mm

-

-

8 mm

AIEP 36 42 080

Neck Ø 4.2 mm

Ø 4.8 mm Neck Ø 4.8 mm

Neck Ø 4.8 mm

Neck Ø 6.5 mm

AIEP 41 42 060*

AIEP 41 48 060*

AIEP 48 48 060*

AIEP 48 65 060*

AIEP 36 48 080

AIEP 41 42 080

AIEP 41 48 080

AIEP 48 48 080

AIEP 48 65 080

10 mm

AIEP 36 42 100

AIEP 36 48 100

AIEP 41 42 100

AIEP 41 48 100

AIEP 48 48 100

AIEP 48 65 100

12 mm

AIEP 36 42 120

AIEP 36 48 120

AIEP 41 42 120

AIEP 41 48 120

AIEP 48 48 120

AIEP 48 65 120

14 mm

AIEP 36 42 140

AIEP 36 48 140

AIEP 41 42 140

AIEP 41 48 140

AIEP 48 48 140

AIEP 48 65 140

* For Ø 6 mm implants: see presentation of the short implants and the specific surgical kit pages 136 - 137.

51

I. Direct handling

Technichal features


Optional instruments

4

Directional indicators for implant

Gingival gauge Ref. AJP 22 280

Ref. APG 20 100

Aesthetica+2

I. Direct handling

INSTRUMENTATION AND KITS

1 mm 2 mm 3 mm 4 mm 5 mm 6 mm Ø 2.2 Depth drilling indication

6 mm 8 mm 10 mm 12 mm 14 mm

Ø 3.7 Gingival height indication

Taps 35 mm

6 mm 8 mm 10 mm 12 mm 14 mm

For implants

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ref. taps

ATB 36 126

ATR 41 126

ATV 48 126

n Colour coded. n Manuel use with the square key (ref. CEC 40) see page 158.

Removable and autoclavable drill stops to manage the drilling depth The surgical kits include a series of drill stops for each implant diameter. Drill stops are easily placed and removed from the drill and allow the dentist to work confidently above nerves and below the sinuses.

1. Stop setting Stop Stop 2. Stop in correct position STOP Dental nerve

52


Mini surgical kit This simplified kit includes all the instruments necessary to place Aesthetica+2 implants Ø 3.6 - 4.1 - 4.8 lengths 8, 10, 12, 14, mm.

4

Ref. AIEKP 36 4X

Aesthetica+2

90 mm

170 mm

n A smaller size to gain space on the sterile field and in the autoclave.

n The second plate can be inclined to better see the instruments during the surgery.

CONTENTS AIEKP 36 4X

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Terminal drills: Direct implant key Direct implant mandrel External hexagonal key External hexagonal mandrel Click wrench Depth gauge Directional indicators for implants

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 Ø 3.6 Ø 4.1 Ø 4.8 Ø 4.8 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 medium - 15 mm short - 20 mm medium - 12 mm short - 22 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 ANFP 42 30 ANFP 42 35 ANFP 48 42 ANFP 48 43 AFD 38 160 AFD 45 160 CCP 42 30 CMP 42 20 CCL HE 12 22 CMA HE 12 22 CCC 120 AJT 22 280 APG 20 100

Pictures for illustration purposes only

53

I. Direct handling

NEW


This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Aesthetica+2 implants Ă˜ 3.6 - 4.1 - 4.8 mm.

4

Additional empty spaces to insert the 3 keys and the 2 direct implant mandrels required to place the implants Natea+ or Uneva+.

Aesthetica+2

I. Direct handling

Complete surgical kit

Ref. AIET P0

1

2

3

4

1 - Integrated graduated ruler 2 - Readibility of the sequences „ step by step presentation „ indications with arrows 3 - Gripping of the stops directly with the contra-angle 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

Pictures for illustration purposes only

54


Cortical drills:

Terminal drills:

Depth gauges:

Hard bone drills:

Removable stops:

Direct implant drivers:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins:

Depth gauge Drill stop tool Directional indicators for implants

CFP 15 22 50 AFI 22 080 AFI 22 060 AFI 22 100

4

AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 ANFP 42 30 ANFP 42 35 ANFP 48 42 ANFP 48 43 AFD 36 160 AFD 38 160 AFD 45 160 AJB 30 280 AJR 35 280 AJV 42 280 AFD 33 160 AFD 38 160 AFD 45 160 ABU 30 060 ABU 30 080 ABU 30 100 ABU 30 120 ABU 30 140 ABU 35 060 ABU 35 080 ABU 35 100 ABU 35 120 ABU 35 140 ABU 42 060 ABU 42 080 ABU 42 100 ABU 42 120 ABU 42 140 NHB 60 060 NHB 60 080 NHB 60 100 CCP 42 20 CCP 42 30 CCP 42 40 CMP 42 20 CMP 42 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120

Ø3 Ø 4.8 Ø 6.5

NAP 15 22 18 AAP 48 22 28 AAP 65 22 28 AJT 22 280 ACB 36 48 APG 20 100

55

I. Direct handling

Intermediary cylindrical drills:

Ø 1.5 - 2.2 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 Ø 3.6 Ø 4.1 Ø 4.8 neck RP Ø 4.8 neck WP for implants Ø 3.6 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 Ø 3.6 Ø 4.1 Ø 4.8 Ø 3.6 Ø 4.1 Ø 4.8 for drills Ø 2.8 and 3 - length 6 mm for drills Ø 2.8 and 3 - length 8 mm for drills Ø 2.8 and 3 - length 10 mm for drills Ø 2.8 and 3 - length 12 mm for drills Ø 2.8 and 3 - length 14 mm for drills Ø 3.3 and 3.5 - length 6 mm for drills Ø 3.3 and 3.5 - length 8 mm for drills Ø 3.3 and 3.5 - length 10 mm for drills Ø 3.3 and 3.5 - length 12 mm for drills Ø 3.3 and 3.5 - length 14 mm for drills Ø 3.8/4/4.2/4.5 - length 6 mm for drills Ø 3.8/4/4.2/4.5 - length 8 mm for drills Ø 3.8/4/4.2/4.5 - length 10 mm for drills Ø 3.8/4/4.2/4.5 - length 12 mm for drills Ø 3.8/4/4.2/4.5 - length 14 mm for drills Ø 4.8/5.2/5.4/5.7 - length 6 mm for drills Ø 4.8/5.2/5.4/5.7 - length 8 mm for drills Ø 4.8/5.2/5.4/5.7 - length 10 mm short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

Aesthetica+2

CONTENTS Point drill Initial drills Ø 2.2: AIET P0


4

TEMPORARY RESTORATION Temporary abutment (implant-holder)

Solid abutment

Straight trans-screwed abutment

Angulated trans-screwed abutment

FINAL RESTORATION

Healing abutment

Aesthetica+2

I. Direct handling

Prosthetic recommendations

10

35

35

35

35

- Single

x

x

x

x

x

- Plural

x

x1

x

x

- Complete

x

x1

x

x

x

x

x

x

x

x

x

Tightening torque (N.cm) - Abutment - Screwed prosthesis Restorations

Prosthesis - Cemented

x

- Trans-screwed/cemented

x

- Screwed - Overdenture Materials - Zirconia - Titanium

x

x

x

- Gold alloy

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

56


Gold palladium abutment

Straight customizable abutment

Non-rotational Esthetibase

Rotational Esthetibase

ConOcta abutment

O'Ring abutment

35 35 35 35 35 35 35

x

x

x

x

x

x

x

x

x

x

x

x

x

x2

x2

x

x 25

x x x

x (x)1 x x x

x x x

x

x x

x

x

x

x

57

4 I. Direct handling

Aesthetica+2

teknikalab customized abutment

FINAL RESTORATION


4

Cemented prosthesis on trans-screwed abutment

1

HEALING ABUTMENTS 10 N.cm

COVER S

TEMPORIZATION

Aesthetica+2

H (mm)

Ø 4.7

Ø 5.5

Ø 7.2

1.5

ACI 42 47 15

ACI 48 55 15

2

------

------

------

3

ACI 42 47 30

ACI 48 55 30

ACI 65 72 30

4.5

ACI 42 47 45

ACI 48 55 45

ACI 65 72 45

Ø

Ø 3.5

H

ACI 65 72 20

ACI 48 3

POP-IN IMPRESSION COPINGS

PICK-UP IMPRESSION COPINGS

Supplied with a fixing screw (ref. APS VG 20 140)

Supplied with a fixing screw (ref. APV VT 20 154)

LABORAT GUIDE SCREW

API 42 85

API 48 85

Ø

API 65 85

APE T42

POP-UP IMPRESSION COPINGS Supplied with a fixing screw (ref. APS VTB 20 174) and an impression cap for pick-up technique

APU T 42

APU T 48

Ø APE T48 APE T65 Different colors according to the version

IMPLANT ANALOGS

Ø mm

Different colors according to the version

ALA H42

ALA H48

Plastic - S (ref. APS VG 20

For gold palladium and Esthetibase abutments

ALA H65

NPS VG 20 160

Different colors according to the version

3

SCANBO

LABORATORY GUIDE SCREW

Ø

Can be cut

APU T 65

APS VG 20

16 mm

IMPRESSION

H 9 mm

2

ETK AE NPSB

ANGULATED ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. APS VF 20 70)

STRAIGHT ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. APS VF 20 112) H 6.5 mm

FINAL RESTORATION

I. Direct handling

A complete prosthetic range

APS PD 48 55

APS PD 65 55

BURN-OUT SLEEVES

Nonrotational

Rotational

APS CCO 42 55

APS CCC 42 55

APS CA 42 47

APS CCO 48 55

APS CCC 48 55

APS CA 48 50

APS CCO 65 55

APS CCC 65 55

APS PA 48 15 APS PA 65 15

20°

APS PA 48 20 APS PA 65 20

Supplied w fixing screw

CUSTOMIZABLE ABUTMENTS 35 N.cm For 15° & 20° angulated abutment

For straight abutment

15°

GOLD PA

H 6.5 mm

APS CA 65 70

APS PS Ø

Supplied with a titanium fixing screw (ref. APS VF 20 112) H 10 mm APS PR 42 100 APS PR 48 150 APS PR 65 120

CUSTOM

Ø

Customized made by ou

ESTHETIBASE ABUTMENTS 35 N.cm

Supplied w (ref. APS VF 20 9

Size L - Supplied with a titanium fixing screw (ref. APS VF 20 93) Ø Ø 4.3

Ø5

Ø 6.5

4.65 mm

Non-rotational APC PTO 42 APC PTO 48 APC PTO 65 Rotational

58

APC PTC 42 APC PTC 48 APC PTC 65

Ø


COVER SCREWS 10 N.cm

H (mm)

ACI 48 35 00

ACI 65 43 00

BITE REGISTRATION ABUTMENT

H 14 mm

LABORATORY GUIDE SCREW APS VG 20 140

TEMPORIZATION

Ø 4.3

9 mm

Ø Ø 3.5

Plastic - Supplied with a fixing screw (ref. APS VG 20 140)

5.5

APS PP 48 55 APS PP 65 55

7

APS PP 48 70

H (mm) 5.8

APS CP 48 40 APS CP 65 40

7.2

APS CP 48 55 APS CP 65 55

8.8

APS CP 48 70

SNAP-ON IMPRESSION COPINGS

4

ETK AE WPSB

APS TCP 48 40 APS TCP 65 40

5.5 APS TCP 48 55 APS TCP 65 55 7

------

APS TCP 48 70

Ø

SNAP-ON OPEN IMPRESSION COPINGS H 10 mm Ø

Single use For adjusted abutments

APS TCP 48 APS TCP 65

Ø

Different colors according to the version

SOLID ABUTMENT ANALOGS

Ø

Can be cut

H

ETK AE RPSB

H

------

H (mm) ETK AE NPSB

H

------

Single use

IMPRESSION

16 mm

RY

APS PP 48 40 APS PP 65 40

PROTECTION CAPS

2

SCANBODY DIRECT ON IMPLANT

4

Different colors according to the version

ETK AIEP PO

on

Aesthetica+2

SOLID ABUTMENTS 35 N.cm

Ht (mm)

APS PS 48 100

APS PS 65 100

CUSTOMIZED ABUTMENT Customized to your case and made by our CAD-CAM center Supplied with a fixing screw (ref. APS VF 20 93)

Ø

4

APS H 48 40

APS H 65 40

5.5

APS H 48 55

APS H 65 55

7

APS H 48 70

------

Different colors according to the version

3 FINAL RESTORATION

Supplied with a M2 titanium fixing screw (ref. APS VF 20 70)

H 10 mm

GOLD PALLADIUM ABUTMENTS 35 N.cm

BURN-OUT SLEEVES

Non-rotational

APS BCO 48 100

APS BCO 65 70

Rotational

APS BCC 48 100

APS BCC 65 70

Ø

KITS

H 4 mm

H 5.5 mm

H 7 mm

H 4 mm

H 5.5 mm

Single-unit prosthesis APS KIT R04 APS KIT R05 APS KIT R07 APS KIT L04 APS KIT L05 Multi-unit prosthesis APS KIT RC4 APS KIT RC5 APS KIT RC7 APS KIT LC4 APS KIT LC5 A kit contains a solid abutment, a protection cap, a snap-on impression coping, a snapon open impression coping, an analog and a burn-out sleeve. Specify the abutment height and the prosthesis type (single or multi-unit).

59

I. Direct handling

1

4

Cemented prosthesis on solid abutment


4

Screwed prosthesis on Conocta abutment

Aesthetica+2

1

PROTECTION CAPS 10 N.cm

CONOCTA ABUTMENTS 35 N.cm

Supplied with a M2 titanium fixing screw (ref. APV VF 20 56)

TEMPORIZATION

H H 1.5 mm

H 1.8 mm

APV PI 48 15

APV PI 65 15

Different colors according to the version

H 5.5 mm APV CP 42

APV CP 48

APV CP 65

Ø

TEMPORARY ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. APV VF 20 56) H 10 mm APV PPT 42 100

APV PPT 48 100

APV PPT 65 100

Ø

2

PO

Sup

PICK-UP IMPRESSION COPINGS

CONOCTA ABUTMENT ANALOGS

Supplied with a fixing screw (ref. APE VTC 20 109)

Can be cut

Ø

API 4

IMPRESSION

H 9 mm APE TC 42 APE TC 48 APE TC 65

Ø Different colors according to the version

PICK

Supp ALA HC 42 ALA HC 48 ALA HC 65 Different colors according to the version

SCANBODY ON CONICAL ABUTMENT

APE

Plastic Supplied with a fixing screw (ref. APS VG 20 56)

POP LABORATORY GUIDE SCREW

ETK AE NPP

ETK AE RPP

ETK AE WPP

Supp and a H 15 mm

APV VG 20 150

APU Differe

3 FINAL RESTORATION

I. Direct handling

A complete prosthetic range - continuation

60

BURN-OUT SLEEVES 25 N.cm Supplied with a fixing screw (ref. APV VF 20 56) H 10 mm Non-rotational

APV BCO 42 100 APV BCO 48 100 APV BCO 65 100

Rotational

APV BCC 42 100 APV BCC 48 100 APV BCC 65 100

Ø


Aesthetica+2

on O’Ring abutment

Ø 5.2 mm 2 mm

O’RING ABUTMENTS 35 N.cm

Ø 2.25 mm

H (mm)

Abutment reference

Abutment + O’Ring kit reference

2

APA OR 48 40 APA OR COMP 48 40

4

APA OR 48 60 APA OR COMP 48 60

H

POP-IN IMPRESSION COPINGS Supplied with a fixing screw (ref. APS VG 20 140)

O’RING ABUTMENT ANALOG Can be cut

API 42 85

API 48 85

API 65 85

OPS HOBI

Ø

IMPLANT ANALOGS Can be cut

Ø

H 9 mm

PICK-UP IMPRESSION COPINGS Supplied with a fixing screw (ref. APV VT 20 154)

n APE T42

APE T48 APE T65 Ø Different colors according to the version

ALA H42

ALA H48

ALA H65

Different colors according to the version

POP-UP IMPRESSION COPINGS

LABORATORY GUIDE SCREW APU T 42 APU T 48 APU T 65 Different colors according to the version

O’RING

Ø mm

APS VG 20 140

H 14 mm

Supplied with a fixing screw (ref. APS VTB 20 174) and an impression cap for pick-up technique

Ø 5.2 mm 2 mm

UPA FOR 52

Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

61

I. Direct handling

4 Overdenture


I. Direct handling

teknika

62


I. Direct handling

EXTERNAL CONNECTION IMPLANT

63


4

Uneva+ is a 2-stage surgery implant based on the latest scientific data to limit marginal bone loss and

optimize primary anchorage. Its external hexagonal connection is Brånemark®-compatible for Ø 3.6 - Ø4.1 implants and thus numerous possibilities are feasible with components of the aforementioned brand.

Uneva+

I. Direct handling

EXTERNAL CONNECTION IMPLANT

Implants Ø 3.6 - 4.1

Bone level implant

A

Brånemark® MK III and MK IV compatibility This connection is available for Ø 3.6 and Ø 4.1 mm.

2.7 mm 0.7 mm

The platform B is equivalent to platform A and prosthetic components from NP and RP platforms can be used to obtain a “Platform Switching” assembly.

Tapered edge 0 mm to 0.15  mm according to the implant Ø

Implants Ø 4.8 - 6 Prosthetic shoulder Available for Ø 4.8 and 6 mm implants, a conical shoulder allows the clinician to increase the height of the connection and therefore the insertion of the abutment providing greater stability. n Better stress distribution. n  Centering of the prosthetic component. n Airtightness of the prosthetic joint guaranteed.

B

2.7 mm

0.7 mm Tapered edge 0.5 mm to 0.6  mm according to the implant Ø

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

64

Total height connection = 1.2 mm : Ø 4.8 = 1.3 mm : Ø 6


Ø 4.1 - 4.2 - 4.9 - 6.2

Microthread 2.9 mm

Uneva+

Sandblasted and etched length

Light conicity «cortical support»

4

Smooth part: 0.4 mm to 0.8  mm according to the implant Ø

Smooth

0.3 mm Thread 0.8 mm

Real screw thread 1.60 mm

Double asymmetrical thread The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

Ø 3.6 - 4.1 - 4.8 - 6

Thread features 7° 0.08 mm 40°

0.3 mm

Thread 0.8 mm

Real screw thread 1.6 mm

Implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Lenght «L»

Ø 3.6 mm

Ø 4.1 mm

6 mm

Ø 4.8 mm

Ø 6 mm

UHDP 48 49 060 *

UHDP 60 62 060 *

8 mm

UHDP 36 41 080

UHDP 41 41 080

UHDP 48 49 080

UHDP 60 62 080

10 mm

UHDP 36 41 100

UHDP 41 41 100

UHDP 48 49 100

UHDP 60 62 100

12 mm

UHDP 36 41 120

UHDP 41 41 120

UHDP 48 49 120

UHDP 60 62 120

14 mm

UHDP 36 41 140

UHDP 41 41 140

UHDP 48 49 140

L

* Implants length 6 mm: see short implant presentation and special surgical kit pages 138 - 139.

65

I. Direct handling

Technichal features


Optional instruments Directional indicators for implant

Gingival gauge Ref. UPG 22 280

4

Ref. UPG 20 100

1 mm 2 mm 3 mm 4 mm 5 mm

Uneva+

I. Direct handling

INSTRUMENTATION AND KITS

Ø 2.45

6 mm 8 mm 10 mm 12 mm 14 mm

Ø 2.2

Depth drilling indication

Gingival height indication

Taps 35 mm

6 mm 8 mm 10 mm 12 mm 14 mm

Implants

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 6 mm

Ref. taps

ATB 36 126

ATR 41 126

ATV 48 126

ATJ 60 120

n Colour coded. n Manuel use with the square key (ref. CEC 40) see page 158.

Removable and autoclavable drill stops to manage the drilling depth The surgical kits include a series of drill stops for each implant diameter. Drill stops are easily placed and removed from the drill and allow the dentist to work confidently above nerves and below the sinuses.

1. Stop setting Stop Stop 2. Stop in correct position STOP Dental nerve

66


Mini surgical kit Ref. UHDKP 36 4X

This simplified kit includes all the instruments necessary to place Uneva+ implants Ø 3.6 - 4.1 - 4.8 lengths 8, 10, 12, 14 mm.

Uneva+

4

90 mm

170 mm

n A smaller size to gain space on the sterile field and in the autoclave.

n The second plate can be inclined to better see the instruments during the surgery.

CONTENTS UHDKP 36 4X

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Terminal drills: Direct implant key Direct implant mandrel External hexagonal key External hexagonal mandrel Click wrench Depth gauge Directional indicators for implants

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 Ø 3.6 Ø 4.1 Ø 4.8 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 medium - 15 mm short - 20 mm medium - 12 mm short - 22 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 ANFP 41 30 ANFP 42 35 ANFP 48 42 AFD 38 160 AFD 45 160 CCP 24 30 CMP 24 20 CCL HE 12 22 CMA HE 12 22 CCC 120 AJT 22 280 UPG 20 100

Pictures for illustration purposes only

67

I. Direct handling

NEW


These surgical kits provide all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Uneva+ implants.

4

Additional empty spaces to insert the 3 keys and the 2 direct implant mandrels required to place the implants Aesthetica+² or Natea+.

Kit «EXPERT 60» Uneva+

Includes instruments for implants Ø 3.6 to 6

Ref. UHDT P6

Kit «EXPERT» Uneva+

Includes instruments for implants Ø 3.6 to 4.8

Ref. UHDT P0

Uneva+

I. Direct handling

Complete surgical kits

1

2

3

4

1 - Integrated graduated ruler 2 - Readibility of the sequences step by step presentation indications with arrows 3 - Gripping of the stops directly with the contra-angle 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

Pictures for illustration purposes only

68


Cortical drills:

Terminal drills:

Removable stops:

Direct implant keys:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins: Initial depth gauge Depth gauges:

Drill stop tool Directional indicators for implants

AFI 22 060 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AFD 48 120 AFD 52 120 AFJ 54 120 ANFP 41 30 ANFP 42 35 ANFP 48 42 ANFP 60 52 AFD 33 160 AFD 38 160 AFD 45 160 AFD 57 120 ABU 30 060 ABU 30 080 ABU 30 100 ABU 30 120 ABU 30 140 ABU 35 060 ABU 35 080 ABU 35 100 ABU 35 120 ABU 35 140 ABU 42 060 ABU 42 080 ABU 42 100 ABU 42 120 ABU 42 140 NHB 60 060 NHB 60 080 NHB 60 100 CCP 24 20 CCP 24 30 CCP 24 40 CMP 24 20 CMP 24 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120

Ø3 Ø 4.8

NAP 15 22 18 AAP 48 22 28 AJT 22 280

Ø 3.6 Ø 4.1 Ø 4.8

AJB 30 280 AJR 35 280 AJV 42 280 ACB 36 48 UPG 20 100

69

I. Direct handling

CFP 15 22 50

4

Intermediary cylindrical drills:

Ø 1.5 - 2.2 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 6 - drill Ø 4.8 for implants Ø 6 - drill Ø 5.2 for implants Ø 6 - drill Ø 5.4 Ø 3.6 Ø 4.1 Ø 4.8 Ø 5.2 for implants Ø 3.6 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 for implants Ø 6 - drill Ø 5.7 for drills Ø 2.8 and 3 - length 6 mm for drills Ø 2.8 and 3 - length 8 mm for drills Ø 2.8 and 3 - length 10 mm for drills Ø 2.8 and 3 - length 12 mm for drills Ø 2.8 and 3 - length 14 mm for drills Ø 3.3 and 3.5 - length 6 mm for drills Ø 3.3 and 3.5 - length 8 mm for drills Ø 3.3 and 3.5 - length 10 mm for drills Ø 3.3 and 3.5 - length 12 mm for drills Ø 3.3 and 3.5 - length 14 mm for drills Ø 3.8/4/4.2/4.5 - length 6 mm for drills Ø 3.8/4/4.2/4.5 - length 8 mm for drills Ø 3.8/4/4.2/4.5 - length 10 mm for drills Ø 3.8/4/4.2/4.5 - length 12 mm for drills Ø 3.8/4/4.2/4.5 - length 14 mm for drills Ø 4.8/5.2/5.4/5.7 - length 6 mm for drills Ø 4.8/5.2/5.4/5.7 - length 8 mm for drills Ø 4.8/5.2/5.4/5.7 - length 10 mm short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

Uneva+

CONTENTS Point drill Initial drills Ø 2.2: UHDT P6


x

x

- Plural

x

- Complete

x

Angulated trans-screwed abutment

- Single

Straight trans-screwed abutment

35

Direct final abutment

Non-rotationnal temporary abutment

10

FINAL RESTORATION

Rotationnal temporary abutment

Healing abutment

4

TEMPORARY RESTORATION

Uneva+

I. Direct handling

Prosthetic recommendations

35

35

35

35

x

x

x

x

x1

x

x

x

1

x

x

x

x

x

x

x

x

x

x

Tightening torque (N.cm) - Abutment - Screwed prosthesis Restorations

Prosthesis - Cemented

x

x

- Trans-screwed/cemented

x

x

x

x

- Screwed - Overdenture Materials - Zirconia - Titanium

x

x

- Gold alloy

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

70


Non-rotational Esthetibase

Rotational Esthetibase

Straight Tetra abutment

Angulated Tetra abutment

Conica abutment

O'Ring abutment

35 35 35 35 35 35 35

x x

x (x)1

x

x x x x

x

x

x

x

x

x2

x2

x

x 20 20 25

x x

x x x

x x x

x

x

x

x x

x

x

x

x

x

71

I. Direct handling

4

Gold palladium abutment

35

Uneva+

Customized abutment teknikalab

FINAL RESTORATION


Cemented prosthesis on trans-screwed abutment

TEMPORIZATION

4

1

Uneva+

HEALING ABUTMENTS 10 N.cm For implants (mm)

Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

Ø 4.8

IMPRESSION

xlp

UCI 37 46 25

UCI 37 51 25

UCI 47 58 25

UCI 60 65 25

2

UCI 37 46 35

UCI 37 51 35

UCI 47 58 35

UCI 60 65 35

3

UCI 37 46 45

UCI 37 51 45

UCI 47 58 45

UCI 60 65 45

1.5 mm h

Healing abutment and final abutment height correspondence

h = supracrestal height

L F A

POP-UP IMPRESSION COPING Supplied with a fixing screw (réf. UPS VTB 20 174) and an impression cap for pick-up technique (ref. APS TCP 48 40)

PICK-UP IMPRESSION COPING

Ø 4.6 mm

UPS TCO 50

Ø 4.1 mm

Lg 8

UPS TCU 50

Ø 4.8 mm

POP-IN IMPRESSION COPINGS

IMPLANT ANALOGS

Ø 3.6 Ø 4.1

Ø 4.5 mm

Ø 5 mm

Ø 6.5 mm Ø

12

Can be cut

For implants (mm)

Supplied with a fixing screw (ref. UPS VG 20 120)

UPS TCF 50 UPS TCF 60 UPS TCF 70

Ø

UPS H 37 UPS H 47

Fo Ø

Ø6

UPS H 60

ET

STRAIGHT ABUTMENTS 35 N.cm

H (mm)

Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

np Ø 4.6

rp Ø 5.1

Ø 4.8

wP Ø 5.8

Ø

Ø6

xlp

h

Ø 6.5

1

UPS PD 46 10

UPS PD 51 10

UPS PD 58 10

UPS PD 65 10

2

UPS PD 46 20

UPS PD 51 20

UPS PD 58 20

UPS PD 65 20

3

UPS PD 46 30

UPS PD 51 30

UPS PD 58 30

UPS PD 65 30

h = supracrestal height

ANGULATED ABUTMENTS 15° 35 N.cm Supplied with a titanium fixing screw (ref. UPS VTH 20 79) For implants Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

np Ø 4.6 UPS PA 46 15

rp Ø 5.1 UPS PA 51 15

For implants Ø 4.8

wP Ø 5.8 UPS PA 58 15

For implants Ø6

CUSTOMIZED ABUTMENT Customized to your case and made by our CAD-CAM center

xlp Ø 6.5

UPS PA 65 15 Ø

ANGULATED ABUTMENTS 20° 35 N.cm

Supplied with a titanium fixing screw (ref. UPS VTH 20 79)

Supplied with a titanium fixing screw (ref. UPS VTH 20 79) For implants Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

For implants Ø 4.8

For implants Ø6

np Ø 4.6

rp Ø 5.1

wP Ø 5.8

xlp

UPS PA 46 20

UPS PA 51 20

UPS PA 58 20

UPS PA 65 20

Ø 6.5

h 1 mm

SC

Pl

Ø 4.8

Supplied with a titanium fixing screw (ref. UPS VTH 20 79) For implants (mm)

72

1.5 mm h

Ø

Ø 6.5

1

Supplied with a fixing screw (ref. UPS VG 20 200)

3

Ø6

wP Ø 5.8

rp Ø 5.1

np Ø 4.6

h (mm)

2

FINAL RESTORATION

I. Direct handling

A complete prosthetic range


TEMPORARY ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. UPS VTH 20 79) Anti-rotational

UPS PT 41 100

Rotational

UPS PTR 41 100

Uneva+

tment utment

10 mm Ø 4.1 mm

LABORATORY GUIDE SCREWS FOR STRAIGHT OR ANGULATED ABUTMENTS

LABORATORY GUIDE SCREWS FOR GOLD PALLADIUM AND ESTHETIBASE ABUTMENTS

Lg (mm)

S

Ø

se -CAM

m 0 79)

8

UPS VG 20 80

12

UPS VG 20 120

16 mm

ence

NPS VG 20 160

LABORATORY GUIDE SCREWS FOR BURN-OUT ABUTMENTS

SCANBODY Plastic - Supplied with a fixing screw (ref. UPS VTH 20 79) For implants (mm) Ø 3.6 and 4.1 mm

For implants (mm) Ø 4.8 mm

For implants (mm) Ø 6 mm

ETK UN 41 SB

ETK UN 48 SB

ETK UN 60 SB

Lenght (mm) 10

UPS VG 20 100

15

UPS VG 20 150

20

UPS VG 20 200

GOLD PALLADIUM ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. UPS VCH 20 79) For implants (mm) Ø 3.6 Ø 4.1

Non-rotational

Rotational

Ø 4.6 - 5 - 6.3 mm

UPS BSH 46 10* UPS BSR 46 10*

Ø 4.8

UPS BSH 50 10

UPS BSR 50 10

Ø6

UPS BSH 63 10

UPS BSR 63 10

h 1 mm

* for implants Ø 4.8 and 6 on emergence switching

BURN-OUT ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. UPS VCH 20 79) For implants (mm) Ø 3.6 Ø 4.1

Non-rotational

Rotational

Ø 4.2 - 5 - 6.3 mm

UPS PHC 42 10* UPS PRC 42 10*

Ø 4.8

UPS PHC 50 10

UPS PRC 50 10

Ø6

UPS PHC 63 10

UPS PRC 63 10

h 1 mm

* for implants Ø 4.8 and 6 on emergence switching

ESTHETIBASE ABUTMENTS 35 N.cm Size L - Supplied with a titanium fixing screw (ref. UPS VTH 20 79) Non-rotational

Rotational

UPC PTO 41

UPC PTC 41

4.65 mm Ø 4.5 mm

Ø 4.1 mm

73

I. Direct handling

4

Cemented prosthesis on trans-screwed abutment


Cemented prosthesis on direct final abutment

4

1 DIRECT FINAL ABUTMENTS Ø 4.8 MM 35 N.cm

TEMPORIZATION

Uneva+

2

Supplied with a titanium fixing screw

h (mm) 1

Coronary height 4.8 mm

Coronary height 5.5 mm

UPS PP 48 40 1

UPS PP 48 55 1

PROTECTION CAPS h

2

UPS PP 48 40 2

UPS PP 48 55 2

Ø 4.1 mm

3

UPS PP 48 40 3

UPS PP 48 55 3

Ø 4.8 mm

H (mm)

H

5.8

APS CP 48 40

7.2

APS CP 48 55

h = supracrestal height

SNAP-ON IMPRESSION COPINGS Single use

10 mm

H 4 mm

H 5.5 mm

APS TCP 48 40 APS TCP 48 55

IMPRESSION

Ø 4.8 mm Different colors according to the version

SNAP-ON OPEN IMPRESSION COPING Single use For adjusted abutments APS TCP 48

H

ABUTMENTS ANALOGS Can be cut

3 FINAL RESTORATION

I. Direct handling

A complete prosthetic range - continuation

74

H 4 mm

H 5.5 mm

APS H 48 40

APS H 48 55

Ø 4.8 mm Different colors according to the version

BURN-OUT SLEEVES Non-rotational APS BCO 48 100 Rotational

APS BCC 48 100

Ø 4.8 mm

KITS

H 4 mm

H 5.5 mm

Non-rotational basis for single-unit prosthesis

NPS KIT N04

NPS KIT N05

Rotational basis for multi-unit prosthesis

NPS KIT NC4

NPS KIT NC5

Supplied without direct final abutment. A kit contains a protection cap, a snap-on impression coping, a snap-on open impression coping, an analog and a burn-out sleeve. Specify the abutment height (4 or 5.5 mm) and the prosthesis type (crown or bridge).

Ø


on Conica abutment

4

1 Supplied with a titanium fixing screw (ref. UPV VCH 16 80))

Uneva+

CONICA ABUTMENT 35 N.cm 2.5 mm

TEMPORIZATION

UPV CH 41 35

PROTECTION CAP

TEMPORARY ABUTMENT

10 N.cm

25 N.cm

UPV PTH 48 100

Supplied with a titanium fixing screw (ref. UPV VPH 16 47)

10 mm

Supplied with a titanium fixing screw (ref. UPV VPH 16 47)

UPU CHT 48 53

Ø 4.8 mm

Ø 4.8 mm 5.4 mm

2 PICK-UP IMPRESSION COPING

IMPRESSION

Supplied with a fixing screw (ref. UPV VGH 16 150)

CONICA ABUTMENT ANALOG

LABORATORY GUIDE SCREW

Can be cut UPV ACH 41

15 mm

UPV TCH 48

UPV VGH 16 150

Supplied with a titanium fixing screw (ref. UPV VPH 16 47) UPV CCH 48 100

Ø 4.8 mm

NON-ROTATIONAL BURN-OUT SLEEVE 25 N.cm Supplied with a titanium fixing screw (ref. UPV VPH 16 47) UPV CCC 48 100

10 mm

ROTATIONAL BURN-OUT SLEEVE 25 N.cm

10 mm

FINAL RESTORATION

3

Ø 4.8 mm

75

I. Direct handling

Screwed prosthesis


Screwed prosthesis on Tetra abutment ANGULATED ABUTMENTS 17° 35 N.cm Supplied with a reusable implant-holder and a titanium fixing screw (ref. UPV VMA 20 61)

STRAIGHT ABUTMENTS 35 N.cm Supplied with a plastic single use implantholder and a titanium fixing screw Fixing screw reference

1

UPV PMD 41 10 UPV VMD 20 74

2

UPV PMD 41 20 UPV VMD 20 84

3

UPV PMD 41 30 UPV VMD 20 94

4

UPV PMD 41 40 UPV VMD 20 104

h

2

UPV PMA 41 17 20

3

UPV PMA 41 17 30

4

UPV PMA 41 17 40

35 N.cm Supplied with a reusable implant-holder and a titanium fixing screw (ref. UPV VMA 20 61)

h

H (mm)

PROTECTION CAPS

Ø 4.8 mm

10 N.cm

UPV CPT 48 20

Long

UPV CPT 48 40

UPV PMA 41 30 30

4

UPV PMA 41 30 40

TEMPORARY ABUTMENT 20 N.cm

2 mm

Short

3

Supplied with a titanium fixing screw (ref. UPV VMD 14 38)

4 mm

11 mm

UPV PMT 48 110

2 PICK-UP IMPRESSION COPING

IMPRESSION

h

ANGULATED ABUTMENTS 30°

Supplied with a fixing screw (ref. UPV VGM 14 150)

Ø 4.8 mm

SCANBODY ON TETRA ABUTMENT 10 mm

Plastic - Supplied with a fixing screw (ref. NPV VG 14 105) Ø 4.8 mm

UPV TM 48

ETK UN SBP

Ø 4.8 mm

POP-IN IMPRESSION COPING UPV PI 48

LABORATORY GUIDE SCREWS

8 mm Ø 4.8 mm

Short

UPV VGM 14 40

Medium

UPV VGM 14 150

15 mm

TEMPORIZATION

Abutment h (mm) reference

H (mm)

4 mm

4

1

Uneva+

SOLID ABUTMENTS ANALOG Can be cut UPV HM 48

3 FINAL RESTORATION

I. Direct handling

A complete prosthetic range - continuation

76

BURN-OUT SLEEVE 20 N.cm Unscrewing treatment Supplied with a titanium fixing screw (ref. UPV VMD 14 38) UPV CMC 48 110

11 mm Ø 4.8 mm

GOLD PALLADIUM ABUTMENT 20 N.cm Supplied with a titanium fixing screw (ref. UPV VMD 14 38) UPV BST 48 110

10 mm 2 mm Ø 4.8 mm


4

on O’Ring abutment

O’RING ABUTMENTS

TEMPORIZATION

35 N.cm Supplied with an O’ring

2

Ø 5.2 mm 2 mm Ø 2.9 mm

h (mm) 2

UPA OR20

4

UPA OR40

6

UPA OR60

h

h = supracrestal height

POP-UP IMPRESSION COPING Supplied with a fixing screw (ref. UPS VTB 20 174) and an impression cap for pick-up technique (ref. APS TCP 48 40)

POP-IN IMPRESSION COPINGS Supplied with a fixing screw (ref. VG 20 120) For implant (mm) Ø 3.6

IMPRESSION

Uneva+

1

Ø 4.1

UPS TCU 50

Ø 4.1 mm

Ø 4.8 mm

UPS TCF 50

Ø 4.8

UPS TCF 60

Ø6

UPS TCF 70

O’RING ABUTMENT ANALOG OPS HOBI

PICK-UP IMPRESSION COPING

IMPLANT ANALOGS Can be cut

Supplied with a fixing screw (ref. UPS VG 20 200)

For implant (mm) Ø 3.6 Ø 4.1

UPS TCO 50

UPS H 37

Ø 4.8

UPS H 47

Ø6

UPS H 60

FINAL RESTORATION

3 Ø 5.2 mm

O’RING 2 mm

UPA FOR 52

Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

77

I. Direct handling

Overdenture


teknika

78


II. Implant-holder

II. IMPLANTS WITH IMPLANT-HOLDER

naturall ANATOMICAL IMPLANT

VERSATILE IMPLANT

TISSUE LEVEL IMPLANT

EXTERNAL TISSUE LEVEL CONNECTION IMPLANT IMPLANT

79


II. Implant-holder

teknika

80


II. Implant-holder

ANATOM ICAL I M PL ANT

naturall

81


ANATOMICAL IMPLANT

naturall

1 Triple function implant-holder n Implant-holder made of grade V titanium (to prevent connection distortion). n Aesthetic yellow colour for temporary abutment use (tightened to 20 N.cm for Ø 3.5 implants and 30 N.cm for implants of other diameters). n Pop-in impression coping function. Delivered connected to the implant.

Naturall

II. Implant-holder

The Naturall tapered implant was designed to enhance implant treatment: optimization of the implant length thanks to an atraumatic tapered extremity, optimization of primary stability thanks to a highly elaborate implant profi le, threaded until the apex, with a tapered support at cortical level and a microthread which acts in perfect synchronicity with the main thread (maximal preservation and stimulation of cortical bone + mechanical blocking). 4 different surgical protocols also allows to consider bone quality in order to better manage primary stability.

Clear limit between implant and implantholder

References T60 grade IV pure titanium. The implants are supplied with a cover screw and a triple function implant-holder.

Lenght «L»

Ø 3.5 mm

Ø 4 mm

Ø 4.5 mm

Ø 5 mm

8 mm

NIC 35 080

NIC 40 080

NIC 45 080

NIC 50 080

10 mm

NIC 35 100

NIC 40 100

NIC 45 100

NIC 50 100

12 mm

NIC 35 120

NIC 40 120

NIC 45 120

NIC 50 120

14 mm

NIC 35 140

NIC 40 140

NIC 45 140

NIC 50 140

L

Fixing screw

!

Don’t use the screw from the implant-holder if you use it as a temporary abutment ; use the screw from the titanium abutment as shown in the table ----->

Implants Ø 3,5 Implants Ø 4 - 4.5 - 5 NVP 35

APS VF 20 112

NEW Mini surgical kit This simplified kit includes all the instruments necessary to place Naturall implants Ø 3.5 - 4 - 4.5.

Ref. NICK 35 4X

Picture for illustration purpose only

82


n A smaller size to gain space on the sterile field and in the autoclave.

1

170 mm

n The second plate can be inclined to better see the instruments during the surgery.

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills: Cortical drills:

Terminal conical drills:

Removable stops for terminal conical drills:

Very hard bone drill:

External hexagonal key External hexagonal mandrel Implant-holder key Implant-holder mandrel Setting key for implant-holder cover end Counter torque key Click wrench Drill stop tool Depth gauge

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 4 - drill Ø 2.6 for implants Ø 4.5 - drill Ø 3 Ø 3.5 Ø4 Ø 4.5 Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 3.5 Ø4 Ø 4.5 medium - 12 mm short - 22 mm medium - 11 mm short - 23 mm

CFP 15 22 50

Naturall

CONTENTS NICK 35 4X

AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 NFB 26 150 NFV 30 150 NFE 35 22 NFE 40 26 NFE 45 30 NFC 35 080 NFC 35 100 NFC 35 120 NFC 35 140 NFC 40 080 NFC 40 100 NFC 40 120 NFC 40 140 NFC 45 080 NFC 45 100 NFC 45 120 NFC 45 140 NBU 35 080 NBU 35 100 NBU 35 120 NBU 35 140 NBU 40 080 NBU 40 100 NBU 40 120 NBU 40 140 NBU 45 080 NBU 45 100 NBU 45 120 NBU 45 140 NFC 35 DO NFC 40 DO NFC 45 DO CCL HE 12 22 CMA HE 12 22 CPI 210 CMI 230 CCA CPI CAR 30 78 CCC 120 NCB 30 50 AJT 22 280

Pictures for illustration purposes only

83

II. Implant-holder

90 mm


Complete surgical kit This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Naturall implants Ø 3.5 - 4 - 4.5 - 5.

1

1

Naturall

II. Implant-holder

Ref. NICT 00

2

3

4

1 - Integrated graduated ruler 2 - Numerical sequences of the instruments for calibrating the implant sockets 3 - Readibility of the sequences step by step presentation indications with arrows 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

CONTENTS NICT 00

Point drill Initial drills Ø 2.2:

Intermediary cylindrical drills:

Pictures for illustration purposes only

84

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 4 - drill Ø 2.6 for implants Ø 4.5 - drill Ø 2.6 for implants Ø 4.5 - drill Ø 3 for implants Ø 5 - drill Ø 2.8 for implants Ø 5 - drill Ø 3.4

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 NFB 26 150 NFV 26 150 NFV 30 150 NFM 28 150 NFM 34 150


Very hard bone drills:

External hexagonal keys:

External hexagonal mandrels: Implant-holder keys:

Implant-holder mandrels: Implant drivers: Setting key for implant-holder cover end Counter torque key Click wrench Mandrel extension Paralleling pins Depth gauge Drill stop tool

NFE 40 26 NFE 45 30 NFE 50 34 NFC 35 080 NFC 35 100 NFC 35 120 NFC 35 140 NFC 40 080 NFC 40 100 NFC 40 120 NFC 40 140 NFC 45 080 NFC 45 100 NFC 45 120 NFC 45 140 NFC 50 080 NFC 50 100 NFC 50 120 NFC 50 140 NBU 35 080 NBU 35 100 NBU 35 120 NBU 35 140 NBU 40 080 NBU 40 100 NBU 40 120 NBU 40 140 NBU 45 080 NBU 45 100 NBU 45 120 NBU 45 140 NBU 50 080 NBU 50 100 NBU 50 120 NBU 50 140 NFC 35 DO NFC 40 DO NFC 45 DO NFC 50 DO CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CPI 170 CPI 210 CPI 260 CMI 230 CMI 280 NDI 16 20 NDI 20 20 CCA CPI CAR 30 78 CCC 120 CRM 340

Ø3

NAP 15 22 18 AJT 22 280 NCB 30 50

85

II. Implant-holder

Removable stops for terminal conical drills:

NFE 35 22

1

Terminal conical drills:

Ø 3.5 Ø4 Ø 4.5 Ø5 Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 5 - length 8 mm Ø 5 - length 10 mm Ø 5 - length 12 mm Ø 5 - length 14 mm Ø 3.5 - length 8 mm Ø 3.5 - length 10 mm Ø 3.5 - length 12 mm Ø 3.5 - length 14 mm Ø 4 - length 8 mm Ø 4 - length 10 mm Ø 4 - length 12 mm Ø 4 - length 14 mm Ø 4.5 - length 8 mm Ø 4.5 - length 10 mm Ø 4.5 - length 12 mm Ø 4.5 - length 14 mm Ø 5 - length 8 mm Ø 5 - length 10 mm Ø 5 - length 12 mm Ø 5 - length 14 mm Ø 3.5 Ø4 Ø 4.5 Ø5 short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm short - 7 mm medium - 11 mm long - 16 mm short - 23 mm long - 26 mm Naturall Ø 3.5 Naturall Ø 4/4.5/5

Naturall

Cortical drills:


II. Implant-holder

teknika

86


II. Implant-holder

VE RSATILE I M PL ANT

87


VERSATILE IMPLANT

Triple function implant-holder

Clear limit between implant and implantholder

2

n Implant-holder made of grade V titanium (to prevent connection distortion). n Aesthetic yellow colour for temporary abutment use (tightened to 20 N.cm for Ø 3.6 implants and 30 N.cm for implants of other diameters). n Pop-in impression coping function. Delivered connected to the implant.

Natea

II. Implant-holder

The Natea straight implant is a bone level « polyvalent » implant that allows to place the prosthetic seal 0.4 mm up the bone crest to facilitate access and maintenance without damaging aesthetics. Its cortical support (tapered neck), associated with a double asymmetrical thread with a microthread allows it to have a good bone anchorage. This implant gathers the most recent research in implantology with a “switching platform” prosthetic connection, ensuring bone stabilization until the implant top.

Implant references T60 grade IV pure titanium. The implants are supplied with a cover screw and a triple function implant-holder.

L Lenght «L»

Ø 3.6 mm

Ø 4.1 mm

6 mm

Ø 4.8 mm

Ø 6 mm

NID 48 49 060

8 mm

NID 36 37 080

NID 41 42 080

NID 48 49 080

NID 60 62 080

10 mm

NID 36 37 100

NID 41 42 100

NID 48 49 100

NID 60 62 100

12 mm

NID 36 37 120

NID 41 42 120

NID 48 49 120

NID 60 62 120

14 mm

NID 36 37 140

NID 41 42 140

NID 48 49 140

Fixing screw

!

Don’t use the screw from the implant-holder if you use it as a temporary abutment ; use the screw from the titanium abutment. ----->

Implants Ø 3,6 Implants Ø 4.1 - 4.8 - 6 NVP 35

APS VF 20 112

INSTRUMENTATION AND KITS

Optional instruments Taps 35 mm

6 mm 8 mm 10 mm 12 mm 14 mm

88

Implants

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 6 mm

Ref. taps

ATB 36 126

ATR 41 126

ATV 48 126

ATJ 60 120

n Colour coded. n Manuel use with the square key (ref. CEC 40) see page 158.


NEW Mini surgical kit This simplified kit includes all the instruments necessary to place Natea implants Ø 3.6 - 4.1 - 4.8 lengths 8, 10, 12, 14 mm.

Ref. NIDK 36 4X

2

170 mm

Natea

n A smaller size to gain space on the sterile field and in the autoclave.

n The second plate can be inclined to better see the instruments during the surgery.

CONTENTS Point drill NIDK 36 4X Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Terminal drills: External hexagonal key External hexagonal mandrel Implant-holder key Implant-holder mandrel Setting key for implant-holder cover end Counter torque key Click wrench Depth gauge

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 3.6 for implants Ø 4.1 for implants Ø 4.8 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 medium - 12 mm short - 22 mm medium - 11 mm short - 23 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 NFE 36 30 NFE 41 35 NFE 48 42 P AFD 38 160 AFD 45 160 CCL HE 12 22 CMA HE 12 22 CPI 210 CMI 230 CCA CPI CAR 30 78 CCC 120 AJT 22 280

Pictures for illustration purposes only

89

II. Implant-holder

90 mm


Complete surgical kits These surgical kits provide all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Natea implants.

1 kit for 4 implants…

2

2

Natea

II. Implant-holder

1

3

1 - Integrated graduated ruler 2 - Readibility of the sequences step by step presentation indications with arrows 3 - Gripping of the stops directly with the contra-angle 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

Common kit ‘EXPERT+ 60’ - Natea Aesthetica+ / Uneva / Unevane

Includes instruments for Natea implants Ø 3.6 to 6

Ref. ANUT 60

Common kit ‘EXPERT+’ - Natea Aesthetica+ / Uneva / Unevane

Includes instruments for implants Ø 3.6 to 4.8

Ref. ANUT 00

Kit ‘EXPERT 60’ Natea Kit ‘EXPERT ’ Natea

CONTENTS Point drill Initial drills Ø 2.2: ANUT 60

Intermediary cylindrical drills:

Pictures for illustration purposes only

90

4

Same contents as the kit ANUT 60 without the 6 countersinks Aesthetica+ Same contents as the kit ANUT 00 without the 6 countersinks Aesthetica+ Ø 1.5 - 2.2 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 6 - drill Ø 4.8 for implants Ø 6 - drill Ø 5.2 for implants Ø 6 - drill Ø 5.4

Ref. NIDT 60 Ref. NIDT 00 CFP 15 22 50 AFI 22 060 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AFD 48 120 AFD 52 120 AFJ 54 120


Removable stops:

External hexagonal keys:

External hexagonal mandrels: Implant-holder keys:

Implant-holder mandrels: Implant drivers:

Setting key for implant-holder cover end Counter torque key Click wrench 4 mm square key for taps Mandrel extension Paralleling pins:

Depth gauge Drill stop tool

AEV 30 48 250 NFE 36 30 NFE 41 30 AEV 35 48 250 6 AEV 35 48 250 NFE 41 35 AEV 42 64 250 6 AEV 42 64 250 NFE 48 42 NFE 48 42 P NFE 60 52 NFE 60 52 P AFD 33 160 AFD 38 160 AFD 45 160 AFD 57 120 AJB 30 280 AJR 35 280 AJV 42 280 ABU 30 060 ABU 30 080 ABU 30 100 ABU 30 120 ABU 30 140 ABU 35 060 ABU 35 080 ABU 35 100 ABU 35 120 ABU 35 140 ABU 42 060 ABU 42 080 ABU 42 100 ABU 42 120 ABU 42 140 NHB 60 060 NHB 60 080 NHB 60 100 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CPI 170 CPI 210 CPI 260 CMI 230 CMI 280 ADI 48 25 UDI 20 25 NDI 16 20 NDI 20 20 CCA CPI CAR 30 78 CCC 120 CEC 40 CRM 340

Ø3 Ø 4.8 Ø 6.5

NAP 15 22 18 AAP 48 22 28 AAP 65 22 28 AJT 22 280 ACB 36 48

91

II. Implant-holder

Depth gauges:

AEV 30 42 250

2

Terminal drills:

for implants Ø 3.6 - Aesthetica+ NP for implants Ø 3.6 - Aesthetica+ RP for implants Ø 3.6 - Natea for implants Ø 3.6 - Uneva for implants Ø 4.1 - Aesthetica+ RP lg 6 mm for implants Ø 4.1 - Aesthetica+ RP for implants Ø 4.1 - Natea/Uneva for implants Ø 4.8 - Aesthetica+ WP lg 6 mm for implants Ø 4.8 - Aesthetica+ WP for implants Ø 4.8 - Natea/Uneva lg 6 mm for implants Ø 4.8 - Natea/Uneva for implants Ø 6 - Natea/Uneva lg 6 mm for implants Ø 6 - Natea/Uneva for implants Ø 3.6 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 for implants Ø 6 - drill Ø 5.7 Ø 3.6 Ø 4.1 Ø 4.8 for drills Ø 2.8 and 3 - length 6 mm for drills Ø 2.8 and 3 - length 8 mm for drills Ø 2.8 and 3 - length 10 mm for drills Ø 2.8 and 3 - length 12 mm for drills Ø 2.8 and 3 - length 14 mm for drills Ø 3.3 and 3.5 - length 6 mm for drills Ø 3.3 and 3.5 - length 8 mm for drills Ø 3.3 and 3.5 - length 10 mm for drills Ø 3.3 and 3.5 - length 12 mm for drills Ø 3.3 and 3.5 - length 14 mm for drills Ø 3.8/4/4.2/4.5 - length 6 mm for drills Ø 3.8/4/4.2/4.5 - length 8 mm for drills Ø 3.8/4/4.2/4.5 - length 10 mm for drills Ø 3.8/4/4.2/4.5 - length 12 mm for drills Ø 3.8/4/4.2/4.5 - length 14 mm for drills Ø 4.8/5.2/5.4/5.7 - length 6 mm for drills Ø 4.8/5.2/5.4/5.7 - length 8 mm for drills Ø 4.8/5.2/5.4/5.7 - length 10 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm short - 7 mm medium - 11 mm long - 16 mm short - 23 mm long - 26 mm Aesthetica+ all diameters Uneva all diameters Natea Ø 3.6 Natea Ø 4.1/4.8/6

Natea

Cortical drills:


Prosthetic recommendations

Temporary abutment (implant-holder)

Straight trans-screwed abutment

Angulated trans-screwed abutment

Customized abutment teknikalab

Gold palladium abutment

10

25

25

25

25

25

- Tightening abutment RP/WP

10

35

35

35

35

35

- Single

x

x

x

x

x

x

- Plural

x

x

x

x

(x)1

- Complete

x

x

x

x

2

1

Healing abutment

FINAL RESTORATION

- Tightening abutment NP

Naturall, Natea

II. Implant-holder

TEMPORARY RESTORATION

Tightening torque (N.cm)

- Tightening screwed prosthesis Restorations

Prosthesis - Cemented

x

x

x

x

x

- Trans-screwed/cemented

x

x

x

x

x

x

x

x

x

- Screwed - Overdenture Materials - Zirconia - Titanium - Gold alloy

x

x

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

92


Non-rotational Esthetibase

Rotational Esthetibase

Straight Plural abutment

Angulated Plural abutment

O'Ring abutment

25 25 25 25 25 25

35 35 35 35 35 35 35

20 20

20

x x

x x x x x

x x x x x

x

x

x 1

1

x

x

x

x

x

x

x

x

x2

x2

x

x

x

x

x x

x

x

93

1 II. Implant-holder

2

ConHex abutment

25

Naturall, Natea

Customizable abutment

FINAL RESTORATION


A complete prosthetic range

Cemented prosthesis on trans-screwed abutment

TEMPORIZATION

1 2 Naturall, Natea

IMPRESSION

2

HEALING ABUTMENTS 10 N.cm For implants Ø 3.5 / 3.6 mm

3

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

For implants Ø 5 / 6 mm

h

H

1

1.5

NCI 46 23

NCI 51 23

NCI 58 23

NCI 58 36

2

1.5

NCI 46 34

NCI 51 34

NCI 58 34

NCI 58 45

3

1.5

NCI 46 45

NCI 51 45

NCI 58 45

NCI 58 54

4

1.5

NCI 46 56

NCI 51 56

NCI 58 54

NCI 58 66

4

2.5

NCI 46 67

NCI 51 67

NCI 58 65

NCI 58 76

ø 5.1

ø 4.6

ø 5.8

h: supracrestal height (mm)

ø 5.8

h

Ø H h

Healing abutment and final abutment height correspondence

POP-IN IMPRESSION COPINGS Supplied with a titanium fixing screw (ref. NVS VG 20 156) For implants Ø 3.5 / 3.6 mm Impression coping Ø 4.5 mm NPI 35

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm Impression coping Ø 5.1 mm NPI 4X

PICK-U For implants Ø 5 / 6 mm Impression coping Ø 5.8 mm NPI 50

Supplied

Ø

SCANBODY DIRECT ON IMPLANT Plastic - Supplied with a fixing screw (ref. NPS VG 16 156) for Ø 3.5 and 3.6 mm and (ref. NPS VG 20 156) for other Ø For implants For implants For implants Ø 4 / 4.5 / Ø 5 / 6 mm Ø 3.5 / 3.6 mm 4.1 / 4.8 mm ETK NA 35 SB ETK NA 4X SB ETK NA 50 SB

IMPLANT ANALOGS For implants Ø 3.5 / 3.6 mm NLA H35

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm NLA H4X

For implants Ø 5 / 6 mm NLA H50

Short H 10 mm Long H 13.5 mm

STRAIGHT ABUTMENTS 35 N.cm - Supplied with a titanium fixing screw For implants Ø 3.5 / 3.6 mm

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm ø 5.1

ø 4.6

FINAL RESTORATION

ø 5.8

15° ANG

For implants Ø 5 / 6 mm ø 5.8

h 1 mm

NPS PD 46 06

NPS PD 51 06

NPS PD 58 06

NPS PD 58 18

h 2 mm

NPS PD 46 16

NPS PD 51 16

NPS PD 58 16

NPS PD 58 26

h 3 mm

NPS PD 46 26

NPS PD 51 26

NPS PD 58 26

NPS PD 58 34

h 4 mm

NPS PD 46 36

NPS PD 51 36

NPS PD 58 34

NPS PD 58 44

Fixing screws

NVP 35

NVP 4X

NVP 4X

NVP 4X

Ø h 1 mm h 2 mm h

h 3 mm h: supracrestal height (mm)

Fixing sc

20° ANG

CUSTOMIZABLE ABUTMENTS 35 N.cm - Supplied with a titanium fixing screw For implants Ø 3.5 / 3.6 mm ø 4.6

Impression copings Fixing screws

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm ø 5.1

ø 5.8

NPS PAT 46 20 NPS PAT 51 20 NPS PAT 58 20 NVP 35

NVP 4X

NVP 4X

For implants Ø 5 / 6 mm 2 mm

ø 5.8

h 1 mm h 2 mm

NPS PAT 58 30 NVP 4X

Ø

h 3 mm

Fixing sc

GOLD PALLADIUM ABUTMENTS 35 N.cm - Supplied with a titanium fixing screw For implants Ø 3.5 / 3.6 mm

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

ESTHE

For implants Ø 5 / 6 mm Ø

ø 4.6

94

ø 5.1

ø 5.8

ø 5.8

h 1 mm

NPS PS 46 06

NPS PS 51 06

NPS PS 58 06

------

h 2 mm

NPS PS 46 06

NPS PS 51 06

NPS PS 58 06

NPS PS 58 06

h 3,2 mm

------

------

------

NPS PS 58 06

Fixing screws

NVP VPA 35

NVP VPA 4X 50

NVP VPA 4X 50

NVP VPA 4X 50

Gold + burn-out

II. Implant-holder

1

Rotation

h h: supracrestal height (mm)

Non-rotat

Fixing sc


2

ment

acrestal mm)

acrestal mm)

Naturall, Natea

height ence

NPS VG 16 156

Short*

NPS VG 16 160

For implants For implants Ø 3.5 / 3.6 mm Ø 4 / 4.5 / 4.1 / 4.8 / 5 / 6 mm ø 5.1

ø 4.6

Short Impression copings H Screws 10 mm Long Impression copings H Screws 13.5 mm

NPE T35

NPE T4X L

NPS VG 16 250

NPS VG 16 250

LABORATORY GUIDE SCREWS Ø 2.0 mm

NPE T50

NPS VG 20 200

NPE T35 L

16 mm

Long

ø 5.8

NPE T4X

NPS VG 16 200

Medium NPS VG 16 200

H

NPE T50 L

Short

NPS VG 20 156

Short*

NPS VG 20 160

25 mm

Short

Supplied with a fixing screw

20 mm

LABORATORY GUIDE SCREWS Ø 1.6 mm PICK-UP IMPRESSION COPINGS

* For gold palladium and Esthetibase NPS VG 20 250 abutments

Medium NPS VG 20 200

NPS VG 20 250

Long

15° ANGULATED ABUTMENTS 35 N.cm - Supplied with a titanium fixing screw For implants Ø 3.5 / 3.6 mm

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

For implants Ø 5 / 6 mm Ø

ø 4.6

ø 5.1

ø 5.8

ø 5.8

h 1 mm

NPS PA 46 15 1

NPS PA 51 15 1

NPS PA 58 15 1

NPS PA 58 15 1W

h 2 mm

NPS PA 46 15 2

NPS PA 51 15 2

NPS PA 58 15 2

NPS PA 58 15 3/2

h 3 mm

NPS PA 46 15 3

NPS PA 51 15 3

NPS PA 58 15 3/2 NPS PA 58 15 3

Fixing screws

NVP 35

NVP 4X

NVP 4X

h h: supracrestal height (mm)

NVP 4X

20° ANGULATED ABUTMENTS 35 N.cm - Supplied with a titanium fixing screw For implants Ø 3.5 / 3.6 mm

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

For implants Ø 5 / 6 mm Ø

ø 4.6

ø 5.1

ø 5.8

ø 5.8

h 1 mm

NPS PA 46 20 1

NPS PA 46 20 1

NPS PA 46 20 1

NPS PA 58 20 1W

h 2 mm

NPS PA 46 20 2

NPS PA 46 20 2

NPS PA 46 20 2

NPS PA 58 20 3/2

h 3 mm

NPS PA 46 20 3

NPS PA 46 20 3

NPS PA 46 20 3/2 NPS PA 58 20 3

Fixing screws

NVP 35

NVP 4X

NVP 4X

h h: supracrestal height (mm)

NVP 4X

ESTHETIBASE INTERFACES 35 N.cm - Size L - Supplied with a titanium fixing screw For implants Ø 3.5 / 3.6 mm

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

For implants Ø 5 / 6 mm

ø 4.6

ø 5.1

Rotational

NPC PTO 35

NPC PTO 4X

NPC PTO 4X 58 NPC PTO 50

Non-rotational

NPC PTC 35

NPC PTC 4X

NPC PTC 4X 58 NPC PTC 50

Fixing screws

NVP VPA 35

NVP 20 85

NVP 20 85

ø 5.8

ø 5.8

NVP 20 85

CAD-CAM CUSTOMIZED ABUTMENT Ø

Customized to your case and made by our CAD-CAM center Supplied with a fixing screw (ref. UPS VTH 20 79)

95

II. Implant-holder

1

Cemented prosthesis on trans-screwed abutment


A complete prosthetic range - continuation

Screwed prosthesis on Plural straight abutment

1

PLURAL STRAIGHT ABUTMENTS 25 N.cm - Nitrured

2

For implants Ø 3.5 / 3.6 mm

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm ø 5.1

TEMPORIZATION

ø 4.6

Naturall, Natea

h 1 mm

ø 5.8

Ø

NPV PP 31 07

NPV PP 37 07

NPV PP 37 07

NPV PP 37 13

h 1,6 mm

------

NPV PP 37 13

NPV PP 37 13

------

h 2,2 mm

NPV PP 31 18

NPV PP 37 18

NPV PP 37 18

NPV PP 37 31

h 3,2 mm

NPV PP 31 28

NPV PP 37 31

NPV PP 37 31

NPV PP 37 41

h 4,2 mm

NPV PP 31 38

NPV PP 37 41

NPV PP 37 41

NPV PP 37 51

h 5,2 mm

NPV PP 31 48

NPV PP 37 51

NPV PP 37 51

NPV PP 37 61

80°

h

h: supracrestal height (mm)

TEMPORARY ABUTMENT

10 N.cm Titanium NPV CPP 38 32

2

Ø 4.8 mm 2.5 mm

Ø 4.7 mm

PLURAL STRAIGHT ABUTMENT ANALOG

10 mm

Supplied with a titanium fixing screw (ref. NPV VP 18 56)

1 mm Ø 4.6 mm

SCANBODY ON CONICAL ABUTMENT Plastic Supplied with a fixing screw (ref. NPV VP 18 56)

Supplied with a titanium fixing screw (ref. NPV VG 18 105) NPV TP 4X

20 N.cm

NPV PPT 46 100

PICK-UP IMPRESSION COPING

IMPRESSION

For implants Ø 5 / 6 mm

ø 5.8

TEMPORARY CAP

Ø 3.8 mm

ETK NA SPD

N

Ø 3.8 mm

LABORATORY GUIDE SCREW

can be cut NPV HP 4X

14.5 mm

NPV VG 18 105

P A

C

N

3 RESTAURATION FINALE

II. Implant-holder

1

96

BURN-OUT SLEEVES 20 N.cm

B

Unscrewing treatment Supplied with a titanium fixing screw (ref. NPV VP 18 56) Ø 4,6 mm

Ø 5.1mm

NPV CCP 35 46

NPV CCP 4X 51

12 mm 1 mm Ø

S t (

N


Screwed prosthesis on Plural angulated abutment 17° PLURAL ANGULATED ABUTMENTS 35 N.cm For implants Ø 5 / 6 mm

ø 5.8

ø 5.8

h 1 mm

NPV PPA 35 17 20

NPV PPA 4X 17 20

NPV PPA 50 17 20

h 2 mm

NPV PPA 35 17 30

NPV PPA 4X 17 30

NPV PPA 50 17 30

h 3 mm

NPV PPA 35 17 40

NPV PPA 4X 17 40

NPV PPA 50 17 40

Fixing screws

NPV VPA 35

NPV VPA 4X 50

NPV VPA 4X 50

Supplied with a titanium fixing screw and a reusable titanium implant-holder

2

ø 5.1

Naturall, Natea

ø 4.6

30° PLURAL ANGULATED ABUTMENTS 35 N.cm For implants Ø 3.5 / 3.6 mm ø 4.6

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm ø 5.1

ø 5.8

For implants Ø 5 / 6 mm ø 5.8

h 3 mm

NPV PPA 35 30 30

NPV PPA 4X 30 30

NPV PPA 50 30 30

h 4 mm

NPV PPA 35 30 40

NPV PPA 4X 30 40

NPV PPA 50 30 40

Fixing screws

NPV VPA 35

NPV VPA 4X 50

NPV VPA 4X 50

Ø 4.05 mm

10 N.cm 4 mm

Supplied with a titanium fixing screw (ref. NPV VPA 14 150) NPV TPA 38

Supplied with a titanium fixing screw (ref. NPV VPA 14 40)

11 mm 1 mm Ø 4.1 mm

NPV TPPA 38

NPV CPA 38 24

PICK-UP IMPRESSION COPING 10 N.cm

h: supracrestal height (mm)

TEMPORARY ABUTMENT 20 N.cm

TEMPORARY CAP Supplied gamma sterilized

h

SCANBODY ON CONICAL ABUTMENT

10 mm

Plastic Supplied with a fixing screw (ref. NPV VPA 14 40) Ø 4 mm

ETK NA SPA

Ø 3.8 mm

LABORATORY GUIDE SCREWS

PLURAL ANGULATED ABUTMENT ANALOG Can be cut

Short

Long

NPV HPA 38

NPV VPA 14 40

NPV VPA 14 150

BURN-OUT SLEEVE 20 N.cm

GOLD PALLADIUM ABUTMENT 20 N.cm

Supplied with a titanium fixing screw (ref. NPV VPA 14 40) NPV CCPA 38

11 mm 1.5 mm Ø 4 mm

Supplied with a titanium fixing screw (ref. NPV VPA 14 40) NPV BSPA 38

10 mm 1.5 mm Ø 4.6 mm

97

II. Implant-holder

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

1

For implants Ø 3.5 / 3.6 mm


A complete prosthetic range - continuation

Screwed prosthesis on ConHex abutment

O’RIN

TEMPORIZATION

1 2 Naturall, Natea

TEMPORARY CAPS

CONHEX ABUTMENTS 25 N.cm For implants For implants Ø 4 / 4.5 / Ø 3.5 / 3.6 mm 4.1 / 4.8 mm ø 4.6

ø 5.1

25°

For implants Ø 5 / 6 mm

ø 5.8

Ø 3.5 mm

Ø 3.5 mm

ø 5.8

h : 3.5 mm

h : 3.5 mm

NPV PI 35 23

NPV PI 4X 31

NPV PI 50 31

2 5.6 mm

3.5 mm

h

h : 2.7 mm

h (mm)

Supplied with a titanium fixing screw (ref. NVP 30)

h: supracrestal height (mm)

4

Plastic

Titanium 10 N.cm

NPV CP 3X

NPV CPC 35

6

h: supra

2

PICK-U

Supplie

POP-IN IMPRESSION COPING 10 N.cm

PICK-UP IMPRESSION COPING 10 N.cm 10.5 mm

IMPRESSION

Supplied with a titanium fixing screw (ref. NPV VG 14 105)

11.5 mm

Short H 10 mm Long H 13.5 mm

Supplied with a titanium fixing screw (ref. NPV VG 14 105)

NPV TC 3X

Ø 3.6 mm

NPI 30

POP-I

Supplie Ø 3.8 mm

SCANBODY ON CONICAL ABUTMENT

CONHEX ABUTMENT ANALOG

Plastic Supplied with a fixing screw (ref. NVP 30)

For Ø 3.5

LABORATORY GUIDE SCREW

Can be cut NPV HC 3X

ETK NX 30 SB

12 mm

Impres Ø4 N

NPV VG 14 105

IMPLA

For im Ø 3.5

NLA

3

RESTAURATION FINALE

II. Implant-holder

1

98

TITANIUM NITRURED ABUTMENT 20 N.cm Supplied with a fixing screw (ref. NVP 30) NPS PD 40 12

Can be shaped but not cut until the circular groove

GOLD PALLADIUM ABUTMENTS 20 N.cm 8.5 mm

1.2 mm Ø 3.6 mm

Supplied with a titanium fixing screw (ref. NVP 30)

10 mm

Non-rotational

1.5 mm

Rotational

NPS BSH 40 100 NPS BSR 40 100

Ø 4 mm

ESTHETIBASE ABUTMENTS FOR ZIRCONIA PROSTHESIS 25 N.cm Single-unit prosthesis (non-rotational) Multi-unit prosthesis(rotational) NPC PTO 3 X

NPC PTC 3 X

Size L - Supplied with a titanium fixing screw (ref. NVP VPA 35)

4,65 mm

Ø 4 mm


Overdenture on O’Ring abutment

Sold single

ø 5.8

For implants Ø 5 / 6 mm

With O’Ring

With O’Ring

Sold single

Ø 5.2 mm 2 mm Sold single

2

NPA OR 35 29

NPA OR NPA OR 35 29 MALE 35 40

NPA OR NPA OR 35 40 MALE 35 60

NPA OR 35 60 MALE

4

NPA OR 4X 34

NPA OR NPA OR 4X 34 MALE 4X 40

NPA OR NPA OR 4X 40 MALE 4X 60

NPA OR 4X 60 MALE

6

NPA OR 50 39

NPA OR NPA OR 50 39 MALE 50 40

NPA OR NPA OR 50 40 MALE 50 60

NPA OR 50 60 MALE

Ø 2.9 mm h

h: supracrestal height (mm) Ø 2.5 mm

PICK-UP IMPRESSION COPINGS O’RING ABUTMENT ANALOG

Supplied with a fixing screw For implants For implants Ø 4 / 4.5 / 4.1 / 4.8 / 5 Ø 3.5 / 3.6 mm / 6 mm

LABORATORY GUIDE SCREWS Ø 1.6 mm

ø 5.8

Short Imp. copings NPE T35 NPE T4X NPE T50 H Screws NPS VG 16 200 NPS VG 20 200 10 mm Long Imp. copings NPE T35 L NPE T4X L NPE T50 L H Screws NPS VG 16 250 NPS VG 20 250 13.5 mm

Short

H

Long

Supplied with a titanium fixing screw (ref. NVS VG 20 156)

Long

NLA H35

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm NLA H4X

NPS VG 20 250

Ø

IMPLANT ANALOGS For implants Ø 3.5 / 3.6 mm

NPS VG 20 156

Medium NPS VG 20 200

25 mm

Impression coping Ø 4.5 mm NPI 35

Short

For implants For implants Ø 4 / 4.5 / 4.1 Ø 5 / 6 mm /4.8 mm Impression coping Impression coping Ø 5.1 mm Ø 5.8 mm NPI 4X NPI 50

16 mm

12 mm

NPS VG 16 250

LABORATORY GUIDE SCREWS Ø 2.0 mm

POP-IN IMPRESSION COPINGS For implants Ø 3.5 / 3.6 mm

NPS VG 16 156

Medium NPS VG 16 200

20 mm

ø 5.1

ø 4.6

OPS HOBI

For implants Ø 5 / 6 mm NLA H50

ANNEAU O’RING

Ø 5.2 mm 2 mm

UPA FOR 52

m

Supplied with 3 different retaining rings

4,65 mm

Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

99

II. Implant-holder

h With O’Ring (mm)

ø 5.8

For implants Ø 4 / 4.5 / 4.1 / 4.8 mm

2

For implants Ø 3.5 / 3.6 mm

Naturall, Natea

ø 5.1

ø 4.6

1

O’RING ABUTMENTS 35 N.cm


II. Implant-holder

teknika

100


II. Implant-holder

TISSU E LEVE L I M PL ANT

101


TISSUE LEVEL IMPLANT

Clear limit between implant and implantholder.

Triple function implant-holder

3

n Implant-holder made of grade V titanium (to prevent connection distortion). n Aesthetic yellow colour for temporary abutment use (tightened to 20 N.cm for Ø 3.6 implants and 30 N.cm for implants of other diameters). n Pop-in impression coping function. Delivered connected to the implant.

Aesthetica+

II. Implant-holder

The Aesthetica+ implant is a tissue level implant for one surgical stage. It is particularly suitable to “make up for” bone level of a long-term edentulous area or to manage the emergence profile of back area restorations. Its 3 platforms allow, in addition, to adapt all clinical situations.

Implant references T60 grade IV pure titanium. The implants are supplied with a healing abutment and a triple function implant-holder.

Ø implant (mm)

Ø 3.6

Ø neck (mm)

4.2

4.8

4.2

4.8

4.8

6.5

-

-

AIE 41 42 060

AIE 41 48 060

AIE 48 48 060

AIE 48 65 060

AIE 36 42 080

AIE 36 48 080

AIE 41 42 080

AIE 41 48 080

AIE 48 48 080

AIE 48 65 080

AIE 36 42 100

AIE 36 48 100

AIE 41 42 100

AIE 41 48 100

AIE 48 48 100

AIE 48 65 100

AIE 36 42 120

AIE 36 48 120

AIE 41 42 120

AIE 41 48 120

AIE 48 48 120

AIE 48 65 120

AIE 36 42 140

AIE 36 48 140

AIE 41 42 140

AIE 41 48 140

AIE 48 48 140

AIE 48 65 140

Lengths 6 8 10 12 14

Ø 4.1

Ø neck

Ø 4.8

L

INSTRUMENTATION AND KITS Optional instruments Taps 35 mm

6 mm 8 mm 10 mm 12 mm 14 mm

102

Implants

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ref. taps

ATB 36 126

ATR 41 126

ATV 48 126

n Colour coded. n Manuel use with the square key (ref. CEC 40) see page 158.

Ø implant


NEW Mini surgical kit This simplified kit includes all the instruments necessary to place Aesthetica+ implants Ø 3.6, 4.1 and 4.8 lengths 8, 10, 12 and 14 mm.

Ref. AIEK 36 4X

3

170 mm

Aesthetica+

n A smaller size to gain space on the sterile field and in the autoclave.

n The second plate can be inclined to better see the instruments during the surgery.

CONTENTS Point drill AIEK 36 4X Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Terminal drills: External hexagonal key External hexagonal mandrel Implant-holder key Implant-holder mandrel Setting key for implant-holder cover end Counter torque key Click wrench Depth gauge Pictures for illustration purposes only

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 3.6 for implants Ø 4.1 for implants Ø 4.8 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 medium - 12 mm short - 22 mm medium - 11 mm short - 23 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AEV 30 42 250 AEV 35 48 250 AEV 42 64 250 AFD 38 160 AFD 45 160 CCL HE 12 22 CMA HE 12 22 CPI 210 CMI 230 CCA CPI CAR 30 78 CCC 120 AJT 22 280

103

II. Implant-holder

90 mm


Complete surgical kits These surgical kits provide all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Aesthetica+ implants.

1 kit for 4 implants…

3

2

Aesthetica+

II. Implant-holder

1

3

1 - Integrated graduated ruler 2 - Readibility of the sequences step by step presentation indications with arrows 3 - Gripping of the stops directly with the contra-angle 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone. Common kit ‘EXPERT+ 60’ - Natea Aesthetica+ / Uneva / Unevane

Includes instruments for implants Ø 3.6 to 6

Ref. ANUT 60

Common kit ‘EXPERT+’ - Natea Aesthetica+ / Uneva / Unevane

Includes instruments for implants Ø 3.6 to 4.8

Ref. ANUT 00

Kit ‘EXPERT’ Aesthetica+

Same contents as kit ANUT 00 without cortical drills Natea and Uneva Ø 3.6

Ref. AIET 00

CONTENTS Point drill Initial drills Ø 2.2: ANUT 60

Intermediary cylindrical drills:

104

4

Pictures for illustration purposes only

Ø 1.5 - 2.2 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 6 - drill Ø 4.8 for implants Ø 6 - drill Ø 5.2 for implants Ø 6 - drill Ø 5.4

CFP 15 22 50 AFI 22 060 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AFD 48 120 AFD 52 120 AFJ 54 120


Removable stops:

External hexagonal keys:

External hexagonal mandrels: Implant-holder keys:

Implant-holder mandrels: Implant drivers:

Setting key for implant-holder cover end Counter torque key Click wrench 4 mm square key for taps Mandrel extension Paralleling pins:

Depth gauge Drill stop tool

AEV 30 48 250 NFE 36 30 NFE 41 30 AEV 35 48 250 6 AEV 35 48 250 NFE 41 35 AEV 42 64 250 6 AEV 42 64 250 NFE 48 42 NFE 48 42 P NFE 60 52 NFE 60 52 P AFD 33 160 AFD 38 160 AFD 45 160 AFD 57 120 AJB 30 280 AJR 35 280 AJV 42 280 ABU 30 060 ABU 30 080 ABU 30 100 ABU 30 120 ABU 30 140 ABU 35 060 ABU 35 080 ABU 35 100 ABU 35 120 ABU 35 140 ABU 42 060 ABU 42 080 ABU 42 100 ABU 42 120 ABU 42 140 NHB 60 060 NHB 60 080 NHB 60 100 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CPI 170 CPI 210 CPI 260 CMI 230 CMI 280 ADI 48 25 UDI 20 25 NDI 16 20 NDI 20 20 CCA CPI CAR 30 78 CCC 120 CEC 40 CRM 340

Ø3 Ø 4.8 Ø 6.5

NAP 15 22 18 AAP 48 22 28 AAP 65 22 28 AJT 22 280 ACB 36 48

105

II. Implant-holder

Depth gauges:

AEV 30 42 250

3

Terminal drills:

for implants Ø 3.6 - Aesthetica+ NP for implants Ø 3.6 - Aesthetica+ RP for implants Ø 3.6 - Natea for implants Ø 3.6 - Uneva for implants Ø 4.1 - Aesthetica+ RP lg 6 mm for implants Ø 4.1 - Aesthetica+ RP for implants Ø 4.1 - Natea/Uneva for implants Ø 4.8 - Aesthetica+ WP lg 6 mm for implants Ø 4.8 - Aesthetica+ WP for implants Ø 4.8 - Natea/Uneva lg 6 mm for implants Ø 4.8 - Natea/Uneva for implants Ø 6 - Natea/Uneva lg 6 mm for implants Ø 6 - Natea/Uneva for implants Ø 3.6 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 for implants Ø 6 - drill Ø 5.7 Ø 3.6 Ø 4.1 Ø 4.8 for drills Ø 2.8 and 3 - length 6 mm for drills Ø 2.8 and 3 - length 8 mm for drills Ø 2.8 and 3 - length 10 mm for drills Ø 2.8 and 3 - length 12 mm for drills Ø 2.8 and 3 - length 14 mm for drills Ø 3.3 and 3.5 - length 6 mm for drills Ø 3.3 and 3.5 - length 8 mm for drills Ø 3.3 and 3.5 - length 10 mm for drills Ø 3.3 and 3.5 - length 12 mm for drills Ø 3.3 and 3.5 - length 14 mm for drills Ø 3.8/4/4.2/4.5 - length 6 mm for drills Ø 3.8/4/4.2/4.5 - length 8 mm for drills Ø 3.8/4/4.2/4.5 - length 10 mm for drills Ø 3.8/4/4.2/4.5 - length 12 mm for drills Ø 3.8/4/4.2/4.5 - length 14 mm for drills Ø 4.8/5.2/5.4/5.7 - length 6 mm for drills Ø 4.8/5.2/5.4/5.7 - length 8 mm for drills Ø 4.8/5.2/5.4/5.7 - length 10 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm short - 7 mm medium - 11 mm long - 16 mm short - 23 mm long - 26 mm Aesthetica+ all diameters Uneva all diameters Natea Ø 3.6 Natea Ø 4.1/4.8/6

Aesthetica+

Cortical drills:


Prosthetic recommendations

Temporary abutment (implant-holder)

Solid abutment

Straight trans-screwed abutment

Angulated trans-screwed abutment

35

35

35

35

- Single

x

x

x

x

x

- Plural

x

x1

x

x

- Complete

x

x1

x

x

x

x

x

x

x

x

x

3

Healing abutment

FINAL RESTORATION

10

Aesthetica+

II. Implant-holder

TEMPORARY RESTORATION

Tightening torque (N.cm) - Abutment - Screwed prosthesis Restorations

Prosthesis - Cemented

x

- Trans-screwed/cemented

x

- Screwed - Overdenture Materials - Zirconia - Titanium

x

x

x

- Gold alloy

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

106


Straight customizable abutment

Non-rotational Esthetibase

Rotational Esthetibase

ConOcta abutment

O'Ring abutment

35 35 35 35 35 35

x x x

x (x)1 x x x

x x x x

x

x

x

x

x

x

x

x

x

x

x

x

x2

x2

x

x

x

25

x x

x

x

x

x

107

II. Implant-holder

3

Gold palladium abutment

35

Aesthetica+

Customized abutment teknikalab

FINAL RESTORATION


A complete prosthetic range

Cemented prosthesis on trans-screwed abutment HEALING ABUTMENTS 10 N.cm

COVER S

TEMPORIZATION

H (mm)

Ø 4.7

Ø 5.5

Ø 7.2

1.5

ACI 42 47 15

ACI 48 55 15

2

------

------

------

3

ACI 42 47 30

ACI 48 55 30

ACI 65 72 30

4.5

ACI 42 47 45

ACI 48 55 45

ACI 65 72 45

Ø

Ø 3.5

H

ACI 65 72 20

ACI 48 3

POP-IN IMPRESSION COPINGS

PICK-UP IMPRESSION COPINGS

Supplied with a fixing screw (ref. APS VG 20 140)

Supplied with a fixing screw (ref. APV VT 20 154)

LABORAT GUIDE SCREW

H 9 mm

3

2

API 42 85

API 48 85

Ø

API 65 85

APE T42

POP-UP IMPRESSION COPINGS Supplied with a fixing screw (ref. APS VTB 20 174) and an impression cap for pick-up technique

APU T 42

APU T 48

Ø APE T48 APE T65 Different colors according to the version

IMPLANT ANALOGS

Ø mm

Different colors according to the version

ALA H42

ALA H48

Plastic - S (ref. APS VG 20

For gold palladium and Esthetibase abutments

ALA H65

NPS VG 20 160

Different colors according to the version

3

SCANBO

LABORATORY GUIDE SCREW

Ø

Can be cut

APU T 65

APS VG 20

16 mm

IMPRESSION

Aesthetica+

ETK AE NPSB

ANGULATED ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. APS VF 20 70)

STRAIGHT ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. APS VF 20 112) H 6.5 mm

FINAL RESTORATION

II. Implant-holder

1

APS PD 48 55

APS PD 65 55

BURN-OUT SLEEVES

Nonrotational

Rotational

APS CCO 42 55

APS CCC 42 55

APS CA 42 47

APS CCO 48 55

APS CCC 48 55

APS CA 48 50

APS CCO 65 55

APS CCC 65 55

APS PA 48 15 APS PA 65 15

20°

APS PA 48 20 APS PA 65 20

Supplied w fixing screw

CUSTOMIZABLE ABUTMENTS 35 N.cm For 15° & 20° angulated abutment

For straight abutment

15°

GOLD PA

H 6.5 mm

APS CA 65 70

APS PS Ø

Supplied with a titanium fixing screw (ref. APS VF 20 112) H 10 mm APS PR 42 100 APS PR 48 150 APS PR 65 120

CUSTOM

Ø

Customized made by ou

ESTHETIBASE ABUTMENTS 35 N.cm

Supplied w (ref. APS VF 20 9

Size L - Supplied with a titanium fixing screw (ref. APS VF 20 93) Ø Ø 4.3

Ø5

Ø 6.5

4.65 mm

Non-rotational APC PTO 42 APC PTO 48 APC PTO 65 Rotational

108

APC PTC 42 APC PTC 48 APC PTC 65

Ø


Cemented prosthesis on solid abutment

1

SOLID ABUTMENTS 35 N.cm

COVER SCREWS 10 N.cm

H (mm)

BITE REGISTRATION ABUTMENT

H 14 mm

LABORATORY GUIDE SCREW APS VG 20 140

Plastic - Supplied with a fixing screw (ref. APS VG 20 140)

------

H (mm) 5.8

APS CP 48 40 APS CP 65 40

7.2

APS CP 48 55 APS CP 65 55

8.8

APS CP 48 70

SNAP-ON IMPRESSION COPINGS

4

ETK AE WPSB

APS TCP 48 40 APS TCP 65 40

5.5 APS TCP 48 55 APS TCP 65 55 7

H 10 mm

------

APS TCP 48 70

Ø

Single use For adjusted abutments

APS TCP 48 APS TCP 65

Ø

Different colors according to the version

SOLID ABUTMENT ANALOGS

Ø

Can be cut

H

ETK AE RPSB

Ø

SNAP-ON OPEN IMPRESSION COPINGS

H (mm) ETK AE NPSB

H

------

Single use

IMPRESSION

16 mm

RY

APS PP 48 70

PROTECTION CAPS

2

SCANBODY DIRECT ON IMPLANT

APS PP 48 55 APS PP 65 55

7

Different colors according to the version

ETK AIEP PO

on

5.5

H

Ht (mm)

APS PS 48 100

APS PS 65 100

CUSTOMIZED ABUTMENT Customized to your case and made by our CAD-CAM center Supplied with a fixing screw (ref. APS VF 20 93)

Ø

4

APS H 48 40

APS H 65 40

5.5

APS H 48 55

APS H 65 55

7

APS H 48 70

------

Different colors according to the version

3 FINAL RESTORATION

Supplied with a M2 titanium fixing screw (ref. APS VF 20 70)

H 10 mm

GOLD PALLADIUM ABUTMENTS 35 N.cm

BURN-OUT SLEEVES

Non-rotational

APS BCO 48 100

APS BCO 65 70

Rotational

APS BCC 48 100

APS BCC 65 70

Ø

KITS

H 4 mm

H 5.5 mm

H 7 mm

H 4 mm

H 5.5 mm

Single-unit prosthesis APS KIT R04 APS KIT R05 APS KIT R07 APS KIT L04 APS KIT L05 Multi-unit prosthesis APS KIT RC4 APS KIT RC5 APS KIT RC7 APS KIT LC4 APS KIT LC5 A kit contains a solid abutment, a protection cap, a snap-on impression coping, a snapon open impression coping, an analog and a burn-out sleeve. Specify the abutment height and the prosthesis type (single or multi-unit).

109

II. Implant-holder

ACI 65 43 00

APS PP 48 40 APS PP 65 40

3

ACI 48 35 00

4

Aesthetica+

Ø 4.3

TEMPORIZATION

Ø 3.5

9 mm

Ø


A complete prosthetic range - continuation

Screwed prosthesis on Conocta abutment

PROTECTION CAPS 10 N.cm

CONOCTA ABUTMENTS 35 N.cm

Supplied with a M2 titanium fixing screw (ref. APV VF 20 56)

3

TEMPORIZATION

H

Aesthetica+

H 1.5 mm

H 1.8 mm

APV PI 48 15

APV PI 65 15

Different colors according to the version

H 5.5 mm APV CP 42

APV CP 48

APV CP 65

Ø

TEMPORARY ABUTMENTS 25 N.cm Supplied with a titanium fixing screw (ref. APV VF 20 56) H 10 mm APV PPT 42 100

APV PPT 48 100

APV PPT 65 100

Ø

2

PO

Sup

PICK-UP IMPRESSION COPINGS

CONOCTA ABUTMENT ANALOGS

Supplied with a fixing screw (ref. APE VTC 20 109)

Can be cut

Ø

API 4

IMPRESSION

H 9 mm APE TC 42 APE TC 48 APE TC 65

Ø Different colors according to the version

PICK

Supp ALA HC 42 ALA HC 48 ALA HC 65 Different colors according to the version

SCANBODY ON CONICAL ABUTMENT

APE

Plastic Supplied with a fixing screw (ref. APS VG 20 56)

POP LABORATORY GUIDE SCREW

ETK AE NPP

ETK AE RPP

ETK AE WPP

Supp and a H 15 mm

APV VG 20 150

APU Differe

3 FINAL RESTORATION

II. Implant-holder

1

110

BURN-OUT SLEEVES 25 N.cm Supplied with a fixing screw (ref. APV VF 20 56) H 10 mm Non-rotational

APV BCO 42 100 APV BCO 48 100 APV BCO 65 100

Rotational

APV BCC 42 100 APV BCC 48 100 APV BCC 65 100

Ø


Overdenture

Ø 5.2 mm 2 mm

O’RING ABUTMENTS 35 N.cm Abutment + O’Ring kit reference

2

APA OR 48 40 APA OR COMP 48 40

4

APA OR 48 60 APA OR COMP 48 60

H

Aesthetica+

H (mm)

3

Ø 2.25 mm

Abutment reference

POP-IN IMPRESSION COPINGS Supplied with a fixing screw (ref. APS VG 20 140)

O’RING ABUTMENT ANALOG Can be cut

API 42 85

API 48 85

API 65 85

OPS HOBI

Ø

IMPLANT ANALOGS Can be cut

Ø

H 9 mm

PICK-UP IMPRESSION COPINGS Supplied with a fixing screw (ref. APV VT 20 154)

n APE T42

APE T48 APE T65 Ø Different colors according to the version

ALA H42

ALA H48

ALA H65

Different colors according to the version

POP-UP IMPRESSION COPINGS

LABORATORY GUIDE SCREW APU T 42 APU T 48 APU T 65 Different colors according to the version

O’RING

Ø mm

APS VG 20 140

H 14 mm

Supplied with a fixing screw (ref. APS VTB 20 174) and an impression cap for pick-up technique

Ø 5.2 mm 2 mm

UPA FOR 52

Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

111

II. Implant-holder

on O’Ring abutment


II. Implant-holder

teknika

112


II. Implant-holder

EXTERNAL CONNECTION IMPLANTS

113


EXTERNAL CONNECTION IMPLANT

Triple function implant-holder

4

n Implant-holder made of grade V titanium (to prevent connection distortion). n Aesthetic yellow colour for temporary abutment use (tightened to 20 N.cm for Ø 3.6 implants and 30 N.cm for implants of other diameters). n Pop-in impression coping function. Delivered connected to the implant.

Uneva - Unevane

II. Implant-holder

The Uneva implant is a 1 or 2 stage(s) implant that backs up with the last scientific data to limit marginal bone loss and optimize primary anchorage. It has a well-tried surface state (20 years of clinical background – many histological studies). Its external hexagonal connection is Brånemark® compatible on the implants Ø 3.6 - Ø4.1, allowing many possibilities of exchanging parts with that brand.

Clear limit between implant and implant-holder.

Classic surgery implant references T60 grade IV pure titanium. The implants are supplied with a cover screw and a guided surgery implant-holder.

Lenght «L»

Ø 3.6 mm

Ø 4.1 mm

6 mm

Ø 4.8 mm

Ø 6 mm

UHD 48 49 060

UHD 60 62 060

8 mm

UHD 36 41 080

UHD 41 41 080

UHD 48 49 080

UHD 60 62 080

10 mm

UHD 36 41 100

UHD 41 41 100

UHD 48 49 100

UHD 60 62 100

12 mm

UHD 36 41 120

UHD 41 41 120

UHD 48 49 120

UHD 60 62 120

14 mm

UHD 36 41 140

UHD 41 41 140

UHD 48 49 140

L

Guided surgery implant references T60 grade IV pure titanium. The implants are supplied with a cover screw and a guided surgery implant-holder.

Lenght «L»

Ø 3.6 mm

Ø 4.1 mm

6 mm

114

Ø 4.8 mm UGC 48 49 060

8 mm

UGC 36 41 080

UGC 41 41 080

UGC 48 49 080

10 mm

UGC 36 41 100

UGC 41 41 100

UGC 48 49 100

12 mm

UGC 36 41 120

UGC 41 41 120

UGC 48 49 120

14 mm

UGC 36 41 140

UGC 41 41 140

UGC 48 49 140

L


TISSUE LEVEL IMPLANT

External connection Unevane implants have been developed for immediate loading on bars, mainly for guided surgery but they can also be used for traditional surgery.

Brånemark® MK III and MK IV compatibility.

2.7 mm

4

0.7 mm

Uneva - Unevane

3 mm

Technichal features Ø 4.1 - 4.2

Supracrestal 3 mm

Smooth

Light conicity «cortical support»

Thread features

Microthread 2.9 mm

0.3 mm

Sandblasted and etched length

40° Thread 0.8 mm

Real screw thread 1.6 mm

7° 0.3 mm

Thread 0.8 mm

Real screw thread 1.60 mm

Double asymmetrical thread The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage Ø 3.6 - 4.1

115

II. Implant-holder

With Unevane implant, manufactured bars using CAD-CAM, can be fixed directly without the need for a temporary abutment. As the manufactured bars are directly transcrewed onto the implants, the prosthetic items are different to those in the Uneva range. The same surgical protocol and the same surgical kit apply for Uneva and Unevane whereas a specific surgical kit is required for guided surgery.


Implant references

Clear limit between implant and implant-holder.

T60 grade IV pure titanium. The implants are supplied with a cover screw usable for guided surgery and a guided surgery implant-holder.

Ø 3.6 mm

Ø 4.1 mm

8 mm

UHE 36 41 080

UHE 41 41 080

10 mm

UHE 36 41 100

UHE 41 41 100

12 mm

UHE 36 41 120

UHE 41 41 120

14 mm

UHE 36 41 140

UHE 41 41 140

3 mm

For classic surgery, it is possible to use the implant-holder ref. UPS TCF 50.

L

4

! Don’t use the screw from the implant-holder if you use it as a temporary abutment ; use the screw form the titanium abutment (ref UPS VTH 20 79).

Uneva - Unevane

II. Implant-holder

Lenght «L»

INSTRUMENTATION AND KITS Optional instruments

Taps 35 mm

6 mm 8 mm 10 mm 12 mm 14 mm

116

Implants

Ø 3.6 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 6 mm

Ref. taps

ATB 36 126

ATR 41 126

ATV 48 126

ATJ 60 120

n Colour coded. n Manuel use with the square key (ref. CEC 40) see page 158.


NEW Mini surgical kit This simplified kit includes all the instruments necessary to place Uneva implants Ø 3.6 - Ø 4.1 - Ø 4.8 lengths 8, 10, 12 and 14 mm.

Ref. UHDK 36 4X

170 mm

Uneva - Unevane

4

n A smaller size to gain space on the sterile field and in the autoclave.

n The second plate can be inclined to better see the instruments during the surgery.

CONTENTS Point drill UHDK 36 4X Initial drills Ø 2.2:

Intermediary cylindrical drills:

Cortical drills:

Terminal drills: External hexagonal key External hexagonal mandrel Implant-holder key Implant-holder mandrel Setting key for implant-holder cover end Counter torque key Click wrench Depth gauge

Ø 1.5 - 2.2 length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 3.6 for implants Ø 4.1 for implants Ø 4.8 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 medium - 12 mm short - 22 mm medium - 11 mm short - 23 mm

CFP 15 22 50 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 NFE 41 30 NFE 41 35 NFE 48 42 P AFD 38 160 AFD 45 160 CCL HE 12 22 CMA HE 12 22 CPI 210 CMI 230 CCA CPI CAR 30 78 CCC 120 AJT 22 280

Pictures for illustration purposes only

117

II. Implant-holder

90 mm


1 kit for 4 implants…

Complete surgical kits These surgical kits provide all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Uneva and Unevane implants.

2

3

4 Uneva - Unevane

II. Implant-holder

1

1 - Integrated graduated ruler 2 - Readibility of the sequences step by step presentation indications with arrows 3 - Gripping of the stops directly with the contra-angle 4 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

4

Common kit ‘EXPERT+ 60’ - Natea Aesthetica+ / Uneva / Unevane

Includes instruments for Natea implants Ø 3.6 to 6

Ref. ANUT 60

Common kit ‘EXPERT+’ - Natea Aesthetica+ / Uneva / Unevane

Includes instruments for implants Ø 3.6 to 4.8.

Ref. ANUT 00

Kit ‘EXPERT 60’ Uneva / Unevane

Same contents as the kit ANUT 60 without the 6 countersinks Aesthetica+ for implants Ø 3.6 - Ø 4.1 - Ø 4.8 and Uneva cortical drill Ø 3.6

Ref. UHDT 60

Kit ‘EXPERT’ Uneva / Unevane

Same contents as the kit ANUT 00 without the 6 countersinks Aesthetica+ pour implant Ø 3.6 - Ø 4.1 Ø 4.8 and Uneva cortical drill Ø 3.6

Ref. UHDT 00

CONTENTS Point drill Initial drills Ø 2.2: ANUT 60

Intermediary cylindrical drills:

118 Pictures for illustration purposes only

Ø 1.5 - 2.2 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm for implants Ø 3.6 - drill Ø 2.8 for implants Ø 3.6 - drill Ø 3 for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 for implants Ø 6 - drill Ø 4.8 for implants Ø 6 - drill Ø 5.2 for implants Ø 6 - drill Ø 5.4

CFP 15 22 50 AFI 22 060 AFI 22 080 AFI 22 100 AFI 22 120 AFI 22 140 AFD 28 160 AFB 30 160 AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AFD 48 120 AFD 52 120 AFJ 54 120


Removable stops:

External hexagonal keys:

External hexagonal mandrels: Implant-holder keys:

Implant-holder mandrels: Implant drivers:

Setting key for implant-holder cover end Counter torque key Click wrench 4 mm square key for taps Mandrel extension Paralleling pins:

Depth gauge Drill stop tool

AEV 30 48 250 NFE 36 30 NFE 41 30 AEV 35 48 250 6 AEV 35 48 250 NFE 41 35 AEV 42 64 250 6 AEV 42 64 250 NFE 48 42 NFE 48 42 P NFE 60 52 NFE 60 52 P AFD 33 160 AFD 38 160 AFD 45 160 AFD 57 120 AJB 30 280 AJR 35 280 AJV 42 280 ABU 30 060 ABU 30 080 ABU 30 100 ABU 30 120 ABU 30 140 ABU 35 060 ABU 35 080 ABU 35 100 ABU 35 120 ABU 35 140 ABU 42 060 ABU 42 080 ABU 42 100 ABU 42 120 ABU 42 140 NHB 60 060 NHB 60 080 NHB 60 100 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CPI 170 CPI 210 CPI 260 CMI 230 CMI 280 ADI 48 25 UDI 20 25 NDI 16 20 NDI 20 20 CCA CPI CAR 30 78 CCC 120 CEC 40 CRM 340

Ø3 Ø 4.8 Ø 6.5

NAP 15 22 18 AAP 48 22 28 AAP 65 22 28 AJT 22 280 ACB 36 48

119

II. Implant-holder

Depth gauges:

AEV 30 42 250

4

Terminal drills:

for implants Ø 3.6 - Aesthetica+ NP for implants Ø 3.6 - Aesthetica+ RP for implants Ø 3.6 - Natea for implants Ø 3.6 - Uneva for implants Ø 4.1 - Aesthetica+ RP lg 6 mm for implants Ø 4.1 - Aesthetica+ RP for implants Ø 4.1 - Natea/Uneva for implants Ø 4.8 - Aesthetica+ WP lg 6 mm for implants Ø 4.8 - Aesthetica+ WP for implants Ø 4.8 - Natea/Uneva lg 6 mm for implants Ø 4.8 - Natea/Uneva for implants Ø 6 - Natea/Uneva lg 6 mm for implants Ø 6 - Natea/Uneva for implants Ø 3.6 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 for implants Ø 6 - drill Ø 5.7 Ø 3.6 Ø 4.1 Ø 4.8 for drills Ø 2.8 and 3 - length 6 mm for drills Ø 2.8 and 3 - length 8 mm for drills Ø 2.8 and 3 - length 10 mm for drills Ø 2.8 and 3 - length 12 mm for drills Ø 2.8 and 3 - length 14 mm for drills Ø 3.3 and 3.5 - length 6 mm for drills Ø 3.3 and 3.5 - length 8 mm for drills Ø 3.3 and 3.5 - length 10 mm for drills Ø 3.3 and 3.5 - length 12 mm for drills Ø 3.3 and 3.5 - length 14 mm for drills Ø 3.8/4/4.2/4.5 - length 6 mm for drills Ø 3.8/4/4.2/4.5 - length 8 mm for drills Ø 3.8/4/4.2/4.5 - length 10 mm for drills Ø 3.8/4/4.2/4.5 - length 12 mm for drills Ø 3.8/4/4.2/4.5 - length 14 mm for drills Ø 4.8/5.2/5.4/5.7 - length 6 mm for drills Ø 4.8/5.2/5.4/5.7 - length 8 mm for drills Ø 4.8/5.2/5.4/5.7 - length 10 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm short - 7 mm medium - 11 mm long - 16 mm short - 23 mm long - 26 mm Aesthetica+ all diameters Uneva all diameters Natea Ø 3.6 Natea Ø 4.1/4.8/6

Uneva - Unevane

Cortical drills:


Guided surgery kit This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Uneva, Unevane and Natea+ implants.

Ref. UGCT 00

4

2

3

Uneva - Unevane

II. Implant-holder

1

1 - Readibility of the sequences step by step presentation indications with arrows 2 - Gripping of the stops directly with the contra-angle 3 - Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

CONTENTS UGCT 00

Drill Ø 1.5 for needle placement Positioning needle Drilling guides:

Gingival trepans: Gingival cutters: Drills Ø 2.2:

Pictures for illustration purposes only

120

UGC FA 15 200 CGC AA 15 280

Ø 2.2 Ø 2.8 Ø3 Ø 3.3 Ø 3.5 Ø 3.8 Ø4 Ø 4.2 RP Ø 4.1 WP Ø 4.8 RP Ø 4.1 WP Ø 4.8 length 6 mm length 8 mm length 10 mm length 12 mm length 14 mm

UGC GP 22 UGC GP 28 UGC GP 30 UGC GP 33 UGC GP 35 UGC GP 38 UGC GP 40 UGC GP 42 TCG 41 49 TCG 48 54 DGCG 41 DGCG 48 NFI 22 145 NFI 22 165 NFI 22 185 NFI 22 205 NFI 22 225


Taps:

Stops for cylindrical drills:

Stops for gingival and cortical drills:

Direct implant keys - Natea+: Direct implant mandrels - Natea+: Implant-holders: Implant-holder key Implant-holder mandrel External hexagonal keys: External hexagonal mandrel Click wrench Setting key for implant-holder cover end Counter torque key 4 mm square key for taps Drill stop tool

NFD 28 185 NFD 28 225 NFB 30 185 NFB 30 225 NFD 33 185 NFD 33 225 NFD 33 185 NFD 33 225 NFR 35 185 NFR 35 225 NFD 38 225 NFD 40 185 NFD 40 225 NFV 42 185 NFV 42 225 NFD 45 185 NFD 45 225 UFE 36 30 UFE 41 30 UFE 41 35 UFE 49 42 06 UET 36 225 UET 41 225 UET 48 225 NHB 45 060 NHB 45 080 NHB 45 100 NHB 45 120 UGC BU RP 085 UGC BU RP 105 UGC BU WP 085 UGC BU WP 105 CMP CG 35 CMP CG 35 CCP CG 35 CCP CG 35 UGC PI UHD 36 L UGC PI UHD 48 L CPI 170 CMI 230 CCL HE 12 18 CCL HE 12 22 CMA HE 12 22 CCC 120 CCA CPI CAR 30 78 CEC 40 CB CG 00

121

II. Implant-holder

NFD 38 185

4

Cortical drills:

for implants Ø 3.6 - drill Ø 2.8 - short for implants Ø 3.6 - drill Ø 2.8 - long for implants Ø 3.6 - drill Ø 3 - short for implants Ø 3.6 - drill Ø 3 - long for implants Ø 3.6 - drill Ø 3.3 - short for implants Ø 3.6 - drill Ø 3.3 - long for implants Ø 4.1 - drill Ø 3.3 - short for implants Ø 4.1 - drill Ø 3.3 - long for implants Ø 4.1 - drill Ø 3.5 - short for implants Ø 4.1 - drill Ø 3.5 - long for implants Ø 4.1 - drill Ø 3.8 - short for implants Ø 4.1 - drill Ø 3.8 - long for implants Ø 4.8 - drill Ø 4 - short for implants Ø 4.8 - drill Ø 4 - long for implants Ø 4.8 - drill Ø 4.2 - short for implants Ø 4.8 - drill Ø 4.2 - long for implants Ø 4.8 - drill Ø 4.5 - short for implants Ø 4.8 - drill Ø 4.5 - long RP Ø 3.6 - Natea RP Ø 3.6 - Uneva RP Ø 4.1 WP Ø 4.8 Ø 3.6 Ø 4.1 Ø 4.8 length 6 mm length 8 mm length 10 mm length 12 mm RP RP+2 WP WP+2 RP WP RP WP long RP long WP short - 7 mm short - 23 mm short - 8 mm medium - 12 mm short - 22 mm

Uneva - Unevane

Final drills:


Prosthetic recommendations

x

- Plural

x

- Complete

x

Angulated trans-screwed abutment

x

Straight trans-screwed abutment

- Single

Direct final abutment

Non-rotationnal temporary abutment 35

FINAL RESTORATION

Rotationnal temporary abutment

Healing abutment 10

4 Uneva - Unevane

II. Implant-holder

TEMPORARY RESTORATION

35

35

35

35

x

x

x

x

x1

x

x

x

1

x

x

x

x

x

x

x

x

x

x

Tightening torque (N.cm) - Abutment - Screwed prosthesis Restorations

Prosthesis - Cemented

x

x

- Trans-screwed/cemented

x

x

x

x

- Screwed - Overdenture Materials - Zirconia - Titanium

x

x

- Gold alloy

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

122


Non-rotational Esthetibase

Rotational Esthetibase

Straight Tetra abutment

Angulated Tetra abutment

Conica abutment

O'Ring abutment

35 35 35 35 35 35 35

x x

x (x)1

x

x x x x

x

x

x

x

x

x2

x2

x

x 20 20 25

x x x x

x x x

x

x

x

x

x

x x

x

x

x

x

123

II. Implant-holder

4

Gold palladium abutment

35

Uneva - Unevane

Customized abutment teknikalab

FINAL RESTORATION


A complete prosthetic range

Cemented prosthesis on trans-screwed abutment

TEMPORIZATION

HEALING ABUTMENTS 10 N.cm For implants (mm)

Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

Ø 4.8

UCI 37 51 25

UCI 47 58 25

UCI 60 65 25

2

UCI 37 46 35

UCI 37 51 35

UCI 47 58 35

UCI 60 65 35

3

UCI 37 46 45

UCI 37 51 45

UCI 47 58 45

UCI 60 65 45

Healing abutment and final abutment height correspondence

L F A

POP-UP IMPRESSION COPING Supplied with a fixing screw (réf. UPS VTB 20 174) and an impression cap for pick-up technique (ref. APS TCP 48 40)

PICK-UP IMPRESSION COPING

4 IMPRESSION

1.5 mm h

h = supracrestal height

Ø 4.6 mm

UPS TCO 50

Ø 4.1 mm

Lg 8

UPS TCU 50

Ø 4.8 mm

POP-IN IMPRESSION COPINGS

IMPLANT ANALOGS

Ø 3.6 Ø 4.1

Ø 4.5 mm

Ø 5 mm

Ø 6.5 mm Ø

12

Can be cut

For implants (mm)

Supplied with a fixing screw (ref. UPS VG 20 120)

Ø

UPS H 37 UPS H 47

Fo Ø

Ø6

UPS H 60

ET

STRAIGHT ABUTMENTS 35 N.cm

H (mm)

Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

np Ø 4.6

rp Ø 5.1

Ø 4.8

wP Ø 5.8

Ø

Ø6

xlp

h

Ø 6.5

1

UPS PD 46 10

UPS PD 51 10

UPS PD 58 10

UPS PD 65 10

2

UPS PD 46 20

UPS PD 51 20

UPS PD 58 20

UPS PD 65 20

3

UPS PD 46 30

UPS PD 51 30

UPS PD 58 30

UPS PD 65 30

h = supracrestal height

ANGULATED ABUTMENTS 15° 35 N.cm Supplied with a titanium fixing screw (ref. UPS VTH 20 79) For implants Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

np Ø 4.6 UPS PA 46 15

rp Ø 5.1 UPS PA 51 15

For implants Ø 4.8

wP Ø 5.8 UPS PA 58 15

For implants Ø6

CUSTOMIZED ABUTMENT Customized to your case and made by our CAD-CAM center

xlp Ø 6.5

UPS PA 65 15 Ø

ANGULATED ABUTMENTS 20° 35 N.cm

Supplied with a titanium fixing screw (ref. UPS VTH 20 79)

Supplied with a titanium fixing screw (ref. UPS VTH 20 79) For implants Ø 3.6 - Ø 4.1 and Ø 4.8 - Ø 6 on emergence switching

For implants Ø 4.8

For implants Ø6

np Ø 4.6

rp Ø 5.1

wP Ø 5.8

xlp

UPS PA 46 20

UPS PA 51 20

UPS PA 58 20

UPS PA 65 20

Ø 6.5

h 1 mm

SC

Pl

Ø 4.8

Supplied with a titanium fixing screw (ref. UPS VTH 20 79) For implants (mm)

124

1.5 mm h

Ø

Ø 6.5

UCI 37 46 25

UPS TCF 50 UPS TCF 60 UPS TCF 70

FINAL RESTORATION

xlp

1

Supplied with a fixing screw (ref. UPS VG 20 200)

3

Ø6

wP Ø 5.8

rp Ø 5.1

np Ø 4.6

h (mm)

2

Uneva - Unevane

II. Implant-holder

1


Cemented prosthesis on trans-screwed abutment

Supplied with a titanium fixing screw (ref. UPS VTH 20 79)

tment utment

Anti-rotational

UPS PT 41 100

Rotational

UPS PTR 41 100

10 mm Ø 4.1 mm

LABORATORY GUIDE SCREWS FOR GOLD PALLADIUM AND ESTHETIBASE ABUTMENTS

Lg (mm)

Ø

se -CAM

m 0 79)

8

UPS VG 20 80

12

UPS VG 20 120

NPS VG 20 160

LABORATORY GUIDE SCREWS FOR BURN-OUT ABUTMENTS

SCANBODY Plastic - Supplied with a fixing screw (ref. UPS VTH 20 79) For implants (mm) Ø 3.6 and 4.1 mm

For implants (mm) Ø 4.8 mm

For implants (mm) Ø 6 mm

ETK UN 41 SB

ETK UN 48 SB

ETK UN 60 SB

Lenght (mm) 10

UPS VG 20 100

15

UPS VG 20 150

20

UPS VG 20 200

Uneva - Unevane

S

4

LABORATORY GUIDE SCREWS FOR STRAIGHT OR ANGULATED ABUTMENTS

16 mm

ence

GOLD PALLADIUM ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. UPS VCH 20 79) For implants (mm) Ø 3.6 Ø 4.1

Non-rotational

Rotational

Ø 4.6 - 5 - 6.3 mm

UPS BSH 46 10* UPS BSR 46 10*

Ø 4.8

UPS BSH 50 10

UPS BSR 50 10

Ø6

UPS BSH 63 10

UPS BSR 63 10

h 1 mm

* for implants Ø 4.8 and 6 on emergence switching

BURN-OUT ABUTMENTS 35 N.cm Supplied with a titanium fixing screw (ref. UPS VCH 20 79) For implants (mm) Ø 3.6 Ø 4.1

Non-rotational

Rotational

Ø 4.2 - 5 - 6.3 mm

UPS PHC 42 10* UPS PRC 42 10*

Ø 4.8

UPS PHC 50 10

UPS PRC 50 10

Ø6

UPS PHC 63 10

UPS PRC 63 10

h 1 mm

* for implants Ø 4.8 and 6 on emergence switching

ESTHETIBASE ABUTMENTS 35 N.cm Size L - Supplied with a titanium fixing screw (ref. UPS VTH 20 79) Non-rotational

Rotational

UPC PTO 41

UPC PTC 41

4.65 mm Ø 4.5 mm

Ø 4.1 mm

125

II. Implant-holder

TEMPORARY ABUTMENTS 35 N.cm


A complete prosthetic range - continuation

Cemented prosthesis on direct final abutment

1 TEMPORIZATION

Supplied with a titanium fixing screw

h (mm) 1

Coronary height 4.8 mm

Coronary height 5.5 mm

UPS PP 48 40 1

UPS PP 48 55 1

PROTECTION CAPS h

2

UPS PP 48 40 2

UPS PP 48 55 2

Ø 4.1 mm

3

UPS PP 48 40 3

UPS PP 48 55 3

Ø 4.8 mm

H (mm)

H

5.8

APS CP 48 40

7.2

APS CP 48 55

h = supracrestal height

4

2

Uneva - Unevane

SNAP-ON IMPRESSION COPINGS Single use

10 mm

H 4 mm

H 5.5 mm

APS TCP 48 40 APS TCP 48 55

IMPRESSION

Ø 4.8 mm Different colors according to the version

SNAP-ON OPEN IMPRESSION COPING Single use For adjusted abutments APS TCP 48

H

ABUTMENTS ANALOGS Can be cut

3 FINAL RESTORATION

II. Implant-holder

DIRECT FINAL ABUTMENTS Ø 4.8 MM 35 N.cm

126

H 4 mm

H 5.5 mm

APS H 48 40

APS H 48 55

Ø 4.8 mm Different colors according to the version

BURN-OUT SLEEVES Non-rotational APS BCO 48 100 Rotational

APS BCC 48 100

Ø 4.8 mm

KITS

H 4 mm

H 5.5 mm

Non-rotational basis for single-unit prosthesis

NPS KIT N04

NPS KIT N05

Rotational basis for multi-unit prosthesis

NPS KIT NC4

NPS KIT NC5

Supplied without direct final abutment. A kit contains a protection cap, a snap-on impression coping, a snap-on open impression coping, an analog and a burn-out sleeve. Specify the abutment height (4 or 5.5 mm) and the prosthesis type (crown or bridge).

Ø


Screwed prosthesis on Conica abutment

1 Supplied with a titanium fixing screw (ref. UPV VCH 16 80))

2.5 mm

PROTECTION CAP

TEMPORARY ABUTMENT

10 N.cm

UPV PTH 48 100

Supplied with a titanium fixing screw (ref. UPV VPH 16 47)

10 mm

Supplied with a titanium fixing screw (ref. UPV VPH 16 47)

UPU CHT 48 53

Ø 4.8 mm

Ø 4.8 mm

4

25 N.cm

5.4 mm

Uneva - Unevane

TEMPORIZATION

UPV CH 41 35

2 PICK-UP IMPRESSION COPING

IMPRESSION

Supplied with a fixing screw (ref. UPV VGH 16 150)

CONICA ABUTMENT ANALOG

LABORATORY GUIDE SCREW

Can be cut UPV ACH 41

15 mm

UPV TCH 48

UPV VGH 16 150

Supplied with a titanium fixing screw (ref. UPV VPH 16 47) UPV CCH 48 100

Ø 4.8 mm

NON-ROTATIONAL BURN-OUT SLEEVE 25 N.cm Supplied with a titanium fixing screw (ref. UPV VPH 16 47) UPV CCC 48 100

10 mm

ROTATIONAL BURN-OUT SLEEVE 25 N.cm

10 mm

FINAL RESTORATION

3

Ø 4.8 mm

127

II. Implant-holder

CONICA ABUTMENT 35 N.cm


A complete prosthetic range - continuation

Screwed prosthesis on Tetra abutment ANGULATED ABUTMENTS 17° 35 N.cm Supplied with a reusable implant-holder and a titanium fixing screw (ref. UPV VMA 20 61)

STRAIGHT ABUTMENTS 35 N.cm Supplied with a plastic single use implantholder and a titanium fixing screw

H (mm)

Fixing screw reference

1

UPV PMD 41 10 UPV VMD 20 74

2

UPV PMD 41 20 UPV VMD 20 84

3

UPV PMD 41 30 UPV VMD 20 94

4

UPV PMD 41 40 UPV VMD 20 104

h

2

UPV PMA 41 17 20

3

UPV PMA 41 17 30

4

UPV PMA 41 17 40

35 N.cm Supplied with a reusable implant-holder and a titanium fixing screw (ref. UPV VMA 20 61)

h

H (mm)

PROTECTION CAPS

Ø 4.8 mm

10 N.cm

UPV CPT 48 20

Long

UPV CPT 48 40

UPV PMA 41 30 30

4

UPV PMA 41 30 40

TEMPORARY ABUTMENT 20 N.cm

2 mm

Short

3

Supplied with a titanium fixing screw (ref. UPV VMD 14 38)

4 mm

11 mm

UPV PMT 48 110

2 PICK-UP IMPRESSION COPING Supplied with a fixing screw (ref. UPV VGM 14 150)

Ø 4.8 mm

SCANBODY ON TETRA ABUTMENT 10 mm

Plastic - Supplied with a fixing screw (ref. NPV VG 14 105) Ø 4.8 mm

UPV TM 48

ETK UN SBP

Ø 4.8 mm

POP-IN IMPRESSION COPING UPV PI 48

LABORATORY GUIDE SCREWS

8 mm Ø 4.8 mm

Short

UPV VGM 14 40

Medium

UPV VGM 14 150

15 mm

IMPRESSION

h

ANGULATED ABUTMENTS 30°

4 mm

4

TEMPORIZATION

Abutment h (mm) reference

Uneva - Unevane

SOLID ABUTMENTS ANALOG Can be cut UPV HM 48

3 FINAL RESTORATION

II. Implant-holder

1

128

BURN-OUT SLEEVE 20 N.cm Unscrewing treatment Supplied with a titanium fixing screw (ref. UPV VMD 14 38) UPV CMC 48 110

11 mm Ø 4.8 mm

GOLD PALLADIUM ABUTMENT 20 N.cm Supplied with a titanium fixing screw (ref. UPV VMD 14 38) UPV BST 48 110

10 mm 2 mm Ø 4.8 mm


Overdenture on O’Ring abutment

O’RING ABUTMENTS

TEMPORIZATION

35 N.cm Supplied with an O’ring

Ø 5.2 mm 2 mm Ø 2.9 mm

h (mm) 2

UPA OR20

4

UPA OR40

6

UPA OR60

h

2

POP-UP IMPRESSION COPING Supplied with a fixing screw (ref. UPS VTB 20 174) and an impression cap for pick-up technique (ref. APS TCP 48 40)

POP-IN IMPRESSION COPINGS Supplied with a fixing screw (ref. VG 20 120) For implant (mm) Ø 3.6

IMPRESSION

Uneva - Unevane

4

h = supracrestal height

Ø 4.1

UPS TCU 50

Ø 4.1 mm

Ø 4.8 mm

UPS TCF 50

Ø 4.8

UPS TCF 60

Ø6

UPS TCF 70

O’RING ABUTMENT ANALOG OPS HOBI

PICK-UP IMPRESSION COPING

IMPLANT ANALOGS Can be cut

Supplied with a fixing screw (ref. UPS VG 20 200)

For implant (mm) Ø 3.6 Ø 4.1

UPS TCO 50

UPS H 37

Ø 4.8

UPS H 47

Ø6

UPS H 60

FINAL RESTORATION

3 Ø 5.2 mm

O’RING 2 mm

UPA FOR 52

Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

129

II. Implant-holder

1


teknika

130


III. SHORT IMPLANTS WITH DIRECT HANDLING

natea

naturall ANATOMICAL IMPLANT

aesthetica

VERSATILE IMPLANT

2

TISSUE LEVEL IMPLANT

III. Short implants

POST-EXTRACTION IMPLANT

EXTERNAL CONNECTION IMPLANT

III. SHORT IMPLANTS WITH IMPLANT-HOLDER

TISSUE LEVEL IMPLANT

VERSATILE IMPLANT

EXTERNAL CONNECTION IMPLANT

131


Prise directe

6 MM SHORT IMPLANTS WITH DIRECT HANDLING This length is only available on wide diameters implants in order to have a sufficient implant/bone contact surface and anchorage. Using short implants allow to avoid bone grafting. Short implants are not recommended for single unit restoration in posterior region. Our Natea+ range is recommended for high density bone (D1 to D3). Our Naturall+ range is recommended for all bone densities (D1 to D4) and our Naturactis range is recommended for low density bones (D2 to D4) and in post-extraction situations.

NEW Availability December 2014

Length 6 mm

Thread features

Naturactis

Ø 4.5 - 5 - 6 Supracrestal 0.4 mm Thread 0,4 mm

Real screw thread 2.4 mm

1.2 mm

Synchronized microthread

2.4 mm

Sandblasted and etched length

III. Short implants

1

Technichal features

Thread 1.2 mm

0.11mm

Thread A Thread B Protrusion A Protrusion B

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Short implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Lenght «L»

Ø 4.5 mm

Ø 5 mm

Ø 6 mm

6 mm

NIP 45 060

NIP 50 060

NIP 60 060

!

Prosthetic range with the same height as that of the Naturall+ range due to this short implant’s smooth neck and bone level positioning (pages 38 to 47).

Special surgical kit for Naturactis short implants Ref. NIPK P 45 6

132


NEW Availability December 2014

Length 6 mm

naturall

Technichal features Ø 4.5 - 5 - 6 Supracrestal 0.4 mm

Smooth

Sandblasted and etched length

Light conicity «cortical support»

Microthread 2.5 mm

Thread features 7°

Thread 1.8 mm

2

0.3 mm

Real screw thread 0.9 mm

Naturall+

The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

40°

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Short implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Lenght «L»

Ø 4.5 mm

Ø 5 mm

Ø 6 mm

6 mm

NICP 45 060

NICP 50 060

NICP 60 060

Prosthetic range presentation pages 38 to 47.

Special surgical kit for Naturall+ short implants Ref. NICK P 45 6

133

III. Short implants

0.08 mm Double asymmetrical thread


Prise directe

natea

Length 6 mm

Technichal features Ø 4.9 - 6.2 Supracrestal 0.4 mm

Smooth

Thread features

Microthread 2.5 mm

7° 0.08 mm Double asymmetrical thread

3

Ø 4.8 - 6

Natea+

III. Short implants

Sandblasted and etched length

Light conicity «cortical support»

40°

The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

0.3 mm

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Short implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Ø implant

Ø 4.1 mm

Ø 4.8 mm

Ø 6 mm

Ø neck

Ø 4.2 mm

Ø 4.9 mm

Ø 6.2 mm

References

NIDP 41 42 060*

NIDP 48 49 060

NIDP 60 62 060

Prosthetic range presentation pages 38 to 47. * Availability December 2014.

134

Thread 1.6 mm

Real screw thread 0.8 mm


Special surgical kit for Natea+ short implants Ref. NIDK P 48 6

n Readibility of the sequences step by step presentation indications with arrows

Cortical drills: Very hard bone drills:

Direct implant keys:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins: Depth gauge Drill stop tool Directional indicators for implants

CFP 15 22 50

+ stop Ø 3 for implants Ø 4.8 - drill Ø 3.5 + stop Ø 3.5 for implants Ø 4.8 - drill Ø 4 + stop Ø 4.2 for implants Ø 6 - drill Ø 4.2 + stop Ø 4.2 for implants Ø 6 - drill Ø 4.8 + stop Ø 6 for implants Ø 6 - drill Ø 5.2 + stop Ø 6 Ø 4.8 Ø6 for implants Ø 4.8 - drill Ø 4.5 + stop Ø 4.2 for implants Ø 6 - drill Ø 5.7 + stop Ø 6 short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

ABU 30 060

AFI 22 060 AFB 30 160 AFR 35 160 ABU 35 060 AFD 40 160 ABU 42 060 AFV 42 160 ABU 42 060 AFD 48 120 NBH 60 060 AFD 52 120 NBH 60 060 ANFP 48 42 ANFP 60 52 AFD 45 160 ABU 42 060 AFD 57 120 NBH 60 060 CCP 35 20 CCP 35 30 CCP 35 40 CMP 35 20 CMP 35 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120

Ø3 Ø 4.8

NAP 15 22 18 AAP 48 22 28 AJT 22 280 ACB 36 48 NPG 16 100

Picture for illustration purpose only

135

III. Short implants

Intermediary cylindrical drills:

Ø 1.5 - 2.2 Length 6 mm

3

Point drill Foret Ø 2.2 Foret Ø 3

Natea+

CONTENTS NIDK P 48 6


Prise directe

aesthetica

2 Length 6 mm

Technichal features Thread features

Ø 4.2 - Ø 4.8- Ø 6.5

7° 0.08 mm

4

Sandblasted and etched length

Light conicity «cortical support»

40°

Microthread 2.5 mm

0.3 mm

Thread 1.6 mm

Double asymmetrical thread The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

Ø 4.1 - Ø 4.8

Aesthetica+2

III. Short implants

Smooth & etched neck 1.3 mm

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Short implant references T60 grade IV pure titanium. The implants are supplied with a healing abutment.

Ø implant

Ø 4.1 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 4.8 mm

Ø neck

Ø 4.2 mm

Ø 4.8 mm

Ø 4.8 mm

Ø 6.5 mm

References

AIEP 41 42 060

AIEP 41 48 060

AIEP 48 48 060

AIEP 48 65 060

Prosthetic range presentation pages 56 to 61.

136

Real screw thread 0.8 mm


Special surgical kit for Aesthetica+2 short implants Ref. AIEK P 48 6

n Readibility of the sequences step by step presentation indications with arrows

Cortical drills:

Very hard bone drills:

Direct implant keys:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins: Initial depth gauge Depth gauges: Drill stop tool Directional indicators for implants

CFP 15 22 50 AFI 22 060 AFB 30 160

+ stop Ø 3 for implants Ø 4.1 - drill Ø 3.3 + stop Ø 3.5 for implants Ø 4.1 - drill Ø 3.5 + stop Ø 3.5 for implants Ø 4.8 - drill Ø 4 + stop Ø 4.2 for implants Ø 4.8 - drill Ø 4.2 + stop Ø 4.2 Ø 4.1 Ø 4.8 - RP Ø 4.8 - WP for implants Ø 4.1 - drill Ø 3.8 + stop Ø 4.2 for implants Ø 4.8 - drill Ø 4.5 + stop Ø 4.2 short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

ABU 30 060 AFD 33 160 ABU 35 060 AFR 35 160 ABU 35 060 AFD 40 160 ABU 42 060 AFV 42 160 ABU 42 060 ANFP 42 35 ANFP 48 42 ANFP 48 43 AFD 38 160 ABU 42 060 AFD 45 120 ABU 42 060 CCP 42 20 CCP 42 30 CCP 42 40 CMP 42 20 CMP 42 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120

Ø 4.8 Ø 6.5

AAP 48 22 28 AAP 65 22 28 AJT 22 280

for implants Ø 4.1 for implants Ø 4.8

AJR 35 280 AJV 42 280 ACB 36 48 APG 20 100

Picture for illustration purpose only

137

III. Short implants

Intermediary cylindrical drills:

Ø 1.5 - 2.2 Length 6 mm

4

Point drill Drill Ø 2.2 Drill Ø 3

Aesthetica+2

CONTENTS NIDK P 48 6


Prise directe

Length 6 mm

Technichal features Thread features Ø 4.9 - 6.2

Supracrestal 0.5 mm to 0.6 mm according to the implant Ø

Sandblasted and etched length

Light conicity «cortical support»

Microthread 2.5 mm

Double asymmetrical thread

5

The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

Direct implant driver n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Short implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

Ø implant

Ø 4.8 mm

Ø 6 mm

Ø neck

Ø 4.9 mm

Ø 6.2 mm

References

UHDP 48 49 060

UHDP 60 62 060

Prosthetic range presentation pages 70 to 77.

138

0.08 mm 40°

0.3 mm

Ø 4.8 - 6

Uneva+

III. Short implants

Smooth

Thread 1.6 mm

Real screw thread 0.8 mm


Special surgical kit for Uneva+ short implants Ref. UHDK P 48 6

n Readibility of the sequences step by step presentation indications with arrows

Cortical drills: Very hard bone drill:

Taps: Direct implant keys:

Direct implant mandrels: External hexagonal keys:

External hexagonal mandrels: Mandrel extension Click wrench Paralleling pins: Drill stop tool Directional indicators for implants

CFP 15 22 50 AFI 22 060 AFB 30 160

+ stop Ø 3 for implants Ø 4.8 - drill Ø 3.5 + stop Ø 3.5 for implants Ø 4.8 - drill Ø 4 + stop Ø 4.2 for implants Ø 6 - drill Ø 4.2 + stop Ø 4.2 for implants Ø 6 - drill Ø 4.8 + stop Ø 6 for implants Ø 6 - drill Ø 5.2 + stop Ø 6 Ø 4.8 Ø6 for implants Ø 4.8 - drill Ø 4.5 + stop Ø 4.2 for implants Ø 6 - drill Ø 5.7 + stop Ø 6 Ø 4.8 Ø6 short - 10 mm medium - 15 mm long - 20 mm short - 20 mm long - 30 mm short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm

ABU 30 060 AFR 35 160 ABU 35 060 AFR 40 160 ABU 42 060 AFV 42 160 ABU 42 060 AFD 48 120 NBH 60 060 AFD 52 120 NBH 60 060 ANFP 48 42 ANFP 60 52 AFD 45 160 ABU 42 060 AFD 57 120 NBH 60 060 ATV 48 140 ATV 60 120 CCP 24 20 CCP 24 30 CCP 24 40 CMP 24 20 CMP 24 30 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CRM 340 CCC 120

Ø3 Ø 4.8

NAP 15 22 18 AAP 48 22 28 ACB 36 48 UPG 20 100

Picture for illustration purpose only

139

III. Short implants

Intermediary cylindrical drills:

Ø 1.5 - 2.2 Length 6 mm

5

Point drill Drill Ø 2.2 Drill Ø 3

Uneva+

CONTENTS NIDK P 48 6


6 MM SHORT IMPLANTS WITH IMPLANT-HOLDER This length is only available on wide diameters implants in order to have a sufficient implant/bone contact surface and anchorage. Using short implants allow to avoid bone grafting. Short implants are not recommended for single unit restoration in posterior region.

Length 6 mm

Ø 4.2 - Ø 4.8- Ø 6.5

Thread features 0.3 mm

Sandblasted and etched length

6

Smooth and etched neck 1.3 mm

Aesthetica+

III. Short implants

Technichal features

40°

Microthread 2,3 mm

Thread 0.8 mm 7° Double asymmetrical thread

Ø 4.1 - Ø 4.8

The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

Short implant references

Ø implant

Ø 4.1 mm

Ø 4.1 mm

Ø 4.8 mm

Ø 4.8 mm

Ø neck

Ø 4.2 mm

Ø 4.8 mm

Ø 4.8 mm

Ø 6.5 mm

References

AIE 41 42 060

AIE 41 48 060

AIE 48 48 060

AIE 48 65 060

Prosthetic range presentation pages 106 to 111.

140

T60 grade IV pure titanium. The implants are supplied with a healing abutment and a triple function implantholder (implant-holder / temporary abutment / pop-in impression coping).


Special surgical kit for Aesthetica+ short implants Ref. AIEK 41 06 00

Readibility of the sequences step by step presentation indications with arrows

Very hard bone drills: Stops:

External hexagonal keys:

External hexagonal mandrels: Implant-holder key Implant-holder mandrel Setting key for implant-holder cover end Counter torque key Click wrench Mandrel extension Paralleling pins: Initial depth gauge Depth gauges: Drill stop tool

CFP 15 22 50 AFI 22 060 AFB 30 160

for implants Ø 4.1 - drill Ø 3.3 for implants Ø 4.1 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 4.8 - drill Ø 4.2 Ø 3.5 Ø 4.1 - RP - length 6 mm Ø 4.2 Ø 4.8 - WP - length 6 mm for implants Ø 4.1 - drill Ø 3.8 for implants Ø 4.8 - drill Ø 4.5 Ø3 Ø 3.5 Ø 4.2 short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm medium - 11 mm short - 23 mm

AFD 33 160 AFR 35 160 AFD 40 160 AFV 42 160 AEV 35 48 250 AEV 35 48 250 6 AEV 42 64 250 AEV 42 64 250 6 AFD 38 160 AFD 45 160 ABU 30 060 ABU 35 060 ABU 42 060 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CPI 210 CMI 230 CCA CPI CAR 30 78 CCC 120 CRM 340

Ø 4.8 Ø 6.5

AAP 48 22 28 AAP 65 22 28 AJT 22 280

for implants Ø 4.1 for implants Ø 4.8

AJR 35 280 AJV 42 280 ACB 36 48

Pictures for illustration purposes only

141

III. Short implants

Cortical drills:

Ø 1.5 - 2.2 Length 6 mm

6

Point drill Drill Ø 2.2 Drill Ø 3 Intermediary cylindrical drills:

Aesthetica+

CONTENTS AIEK 41 06 00


Length 6 mm Technichal features Thread features

Ø 4.9 - 6.2

0.3 mm

Supracrestal 0.4 mm

Sandblasted and etched length

Smooth

Light conicity «cortical support»

Microthread 2.9 mm

40° Thread 0.8 mm

Double asymmetrical thread

The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

Ø 4.8 - 6

Ø implant

Ø 4.8 mm

Ø 6 mm

Ø neck

Ø 4.9 mm

Ø 6.2 mm

References

NID 48 49 060

NID 60 62 060

T60 grade IV pure titanium. The implants are supplied with a cover screw and a triple function implant-holder (implant-holder / temporary abutment / pop-in impression coping).

8 7

Prosthetic range presentation pages 92 to 99.

Length 6 mm Technichal features Ø 4.9 - 6.2

Thread features Supracrestal 0.4 mm

Smooth Sandblasted and etched length

Natea, Uneva

III. Short implants

Short implant references

Light conicity «cortical support»

Microthread 2.9 mm

0.3 mm

40° Thread 0.8 mm

Double asymmetrical thread

Ø 4.8 - 6

The threads start from the apex giving the implant a high self-tapping capacity and better apical anchorage

Short implant references Ø implant

Ø 4.8 mm

Ø 6 mm

Ø neck

Ø 4.9 mm

Ø 6.2 mm

References

UHD 48 49 060

UHD 60 62 060

Prosthetic range presentation pages 122 to 129.

142

T60 grade IV pure titanium. The implants are supplied with a cover screw and a triple function implant-holder (implant-holder / temporary abutment / popin impression coping).


Special common surgical kit for Natea / Uneva short implants Ref. NUK 48 06 00 Management of drill use You can mark how many times you have used the drills using the cursors. The cutting effiency of the drills decreases after each use and may overheat the bone. This simple process will enable you to change your drills early enough to avoid any permanent deterioration of the peri-implant bone.

Readibility of the sequences step by step presentation indications with arrows

Hard bone drills: Stops:

External hexagonal keys:

External hexagonal mandrels: Implant-holder keys:

Implant-holder mandrel Implant drivers:

AFB 30 160

for implants Ø 4.8 - drill Ø 3.5 for implants Ø 4.8 - drill Ø 4 for implants Ø 6 - drill Ø 4.2 for implants Ø 6 - drill Ø 4.8 for implants Ø 6 - drill Ø 5.2 for implants Ø 4.8 - Natea/Uneva lg 6 mm for implants Ø 6 - Natea/Uneva lg 6 mm for implants Ø 4.8 - drill Ø 4.5 for implants Ø 6- drill Ø 5.7 Ø3 Ø 3.5 Ø 4.2 Ø6 short - 8 mm medium - 12 mm long - 20 mm short - 22 mm long - 26 mm short - 7 mm medium - 11 mm long - 16 mm short - 23 mm Uneva Natea

Setting key for implant-holder cover end Counter torque key Click wrench Mandrel extension Paralleling pins: Depth gauge Drill stop tool

Pictures for illustration purposes only

AFI 22 060 AFR 35 160 AFD 40 160 AFV 42 160 AFD 48 120 AFD 52 120 NFE 48 42 NFE 60 52 AFD 45 160 AFD 57 120 ABU 30 060 ABU 35 060 ABU 42 060 NHB 60 060 CCL HE 12 18 CCL HE 12 22 CCL HE 12 30 CMA HE 12 22 CMA HE 12 26 CPI 170 CPI 210 CPI 260 CMI 230 UDI 20 25 NDI 20 20 CCA CPI CAR 30 78 CCC 120 CRM 340

Ø3 Ø 4.8

NAP 15 22 18 AAP 48 22 28 AJT 22 280 ACB 36 48

143

III. Short implants

Cortical drills:

CFP 15 22 50

8 7

Drill Ø 3 Intermediary cylindrical drills:

Ø 1.5 - 2.2 Length 6 mm

Natea, Uneva

Point drill CONTENTS NUK 48 06 00 Drill Ø 2.2


teknika

144


IV. NARROW IMPLANTS Ø 3 MM

Ø3

POST-EXTRACTION IMPLANT

naturall

Ø3

ANATOMICAL IMPLANT

IV. Narrow implants

IV. MINI BALL IMPLANT Ø 2.7 MM

Ø 2,7

MINI BALL IMPLANT

145


NEW

NATURACTIS Ø 3 MM Used in one or two-stage surgery, the Naturactis    Ø   3  mm implant has a "morse taper" internal connection; its 3 mm diameter makes this implant suitable for restorations of central or lateral incisors. Its cylindrical-conical body and its significant thread depth make it particularly suitable for post-extraction surgery.

Tapered implant body

Direct implant driver

n Optimization of the primary stability.

n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Thread depth increases at the apex n Optimal apical anchorage in low density bone.

Narrow, active apex n n n n n n

Start of the thread in the form of a blade. Depth of blade greater on apical part than the body of the implant. Optimal anchorage in cancellous bone. Good self-tapping capacity. Ideal for post-extractional surgery. Facilitates the choice of implant axis.

Technichal features

Implant references T60 grade IV pure titanium. Implants are supplied with a cover screw.

1 Thread 0.4 mm

Naturactis

Synchronized microthread (6 threads)

Thread features Ø3

Real screw thread 2.4 mm

Thread 1.2 mm

Sandblasted and etched length

IV. Narrow implants

Ø3

1.2 0.11 mm mm

Lenght «L»

Ø 3 mm

8 mm

NIP 30 080

10 mm

NIP 30 100

12 mm

NIP 30 120

14 mm

NIP 30 140

L

Surgical kit 2.4 mm

This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Naturactis Ø 3. Ref. NIPK P 30

Thread A Thread B Protrusion A Protrusion B

146


NEW

NATURALL+ Ø 3 MM

naturall

Used in one or two-stage surgery, the Naturall+ Ø 3 implant has a "morse taper" internal connection ; its narrow diameter at the apex makes this implant suitable for restorations of the central or lateral incisors when the roots converge.

Tapered implant body n n n n

Direct implant driver

Optimization of the implant placement close to curved roots. Optimization of the primary stability. Limits the apical compression. Atraumatic insertion in risky areas (sinus, dental nerve…).

n Saves time during surgery. n Improves visibility of placement and orientation of the connection. n Indicates gingival height.

Primary stability n Optimisation of the primary stability thanks to the taper of the implant and the adjustment of the compression according to the bone quality. n Threaded to the apex of the implant thus providing good apical anchorage. n Optimal primary anchorage thanks to the slightly tapered microthread with cortical support. n Better distribution of the stress within the bone thanks to the synchronisation between the microthreads, the macrothreads and the protrusions.

n The slight taper of the neck is useful in cases where the crestal bone is very thin and where the mesio-distal spaces are narrow. n Allows for a wider choice of prosthetics. n Eliminates the need, in certain cases, for bone grafting.

Implant references

Bone level prosthetic joint

T60 grade IV pure titanium. Implants are supplied with a cover screw.

Ø3 Supracrestal 0.4 mm

Smooth

Sandblasted and etched length

Microthread

Ø 3 mm

8 mm

NICP 30 080

10 mm

NICP 30 100

12 mm

NICP 30 120

14 mm

NICP 30 140

L

2

Technichal features

Lenght «L»

Naturall+

n More visible and more accessible with the probe. n It can be more easily controlled by the practitioner during sealing and long term care of the implant. n Machined micro-grooves on the neck with a 0.2 µm Ra: perfect attachment of the soft tissue thanks to the specific position of the collagen fibers.

Surgical kit This surgical kit provides all the instruments necessary to carry out the surgical procedure and to manage all bone densities for Naturall+ Ø 3. Ref. NICK P 30

Thread 0.9 mm

Real screw thread 1.80 mm

Double asymmetrical thread

147

IV. Narrow implants

Respects the anatomy


Prosthetic recommendations

TEMPORARY RESTORATION

Healing abutment

Rotationnal temporary abutment

Solid abutment

Straight trans-screwed abutment

Angulated trans-screwed abutment

Customized abutment teknikalab

Gold palladium abutment

Rotational Esthetibase

O'Ring abutment

FINAL RESTORATION

10

20

20

20

20

20

20

20

20

- Single

x

x

x

x

x

x

x

x

- Plural

x

x1

x

x

x

(x)1

- Complete

x

x1

x

x

x

x

x

x

x

x

x

x

x

x

x

x

Tightening torque (N.cm) - Abutment

2

1

Restorations

x

Prosthesis

Naturactis, Naturall+

IV. Narrow implants

- Screwed prosthesis

- Cemented

x

- Trans-screwed / cemented

x

- Screwed - Overdenture

x

Materials - Zirconia - Titanium - Gold alloy

x2 x

x

x

x

x

x

x x

() : Indications under certain clinical conditions 1 : Within the limit of the divergences of the prosthetic axes and a reduced number of components (4-6 min to 8 max) 2 : Zirconia abutment on a titanium Esthetibase base plate

148

x


A complete prosthetic range

NEW

Overdenture on O’Ring abutment

TEMPORIZATION

1

2

Ø 5.2 mm

O’RING ABUTMENT 25 N.cm

2 mm Ø 2.9 mm

h (mm) 2

With O’Ring

Sold single

NPA OR 31 29

NPA OR 31 29 MALE

h

h: supracrestal height (mm)

PICK-UP IMPRESSION COPING 10 N.cm

Reference

Short

Impression

NPE T30

Fixing screw

NPS VG 14 200

10 mm

Supplied with a fixing screw

Ø 3 mm

Supplied with a titanium fixing screw (réf. NPS VTB 14 156) NPI 31 Ø 2.5 mm

Can be cut

OPS HOBI

NLA H30

NPS VG 14 200

Long

NPS VG 14 250

Naturactis, Naturall+

FINAL RESTORATION

3

Medium

25 mm

20 mm

LABORATORY GUIDE SCREWS

Ø 5.2 mm

O’RING

2 mm

UPA FOR 52 Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

149

IV. Narrow implants

O’RING ABUTMENT ANALOG

Ø 3 mm

1

IMPLANT ANALOG

2

IMPRESSION

POP-IN IMPRESSION COPING


A complete prosthetic range - continuation

NEW

Cemented prosthesis on trans-screwed abutment

TEMPORIZATION

1

1

h

h (mm) 1

NCI 30 23

3

NCI 30 45

5

NCI 30 67

h

1.5 mm Healing abutment and final abutment height correspondence

Ø 3 mm Ø 3 mm

POP-IN IMPRESSION COPING

IMPLANT ANALOG

Supplied with a titanium fixing screw

Can be cut NLA H30

NPI 31

PICK-UP IMPRESSION COPING 10 N.cm Supplied with a fixing screw Reference

Short

Impression

NPE T30

Fixing screw

NPS VG 14 200

STRAIGHT ABUTMENTS 25 N.cm Supplied with a titanium fixing screw

Ø 3 mm

2

h (mm) 1

NPS PD 30 06

3

NPS PD 30 26

5

NPS PD 30 46

h

FINAL RESTORATION

h: supracrestal height (mm)

Naturactis, Naturall+

IV. Narrow implants

3

Ø 3 mm

10 mm

IMPRESSION

2

HEALING ABUTMENTS 10 N.cm

GOLD PALLADIUM ABUTMENT 20 N.cm

Ø 3 mm Gold + burn-out

Supplied with a titanium fixing screw

Supracrestal height 2 mm

NPS PS 30 16

ESTHETIBASE ABUTMENTS FOR ZIRCONIA PROSTHESIS 20 N.cm Size S Supplied with a titanium fixing screw Single-unit prosthesis (non-rotational) NPC PTO 30 16

150

4,65 mm

Ø 4 mm


Cemented prosthesis on trans-screwed abt.

Cemented prosthesis on solid abt.

1 SOLID ABUTMENTS 35 N.cm Ø 3 mm

Supplied with a titanium fixing screw

height 1 mm

NPS PPT 30 1

Medium

Long

NPS VG 14 200

NPS VG 14 250

h (mm) 1

H 5.5 mm

H

NPS PP 30 55 1

3

NPS PP 30 55 3

5

NPS PP 30 55 5

h

h: supracrestal height (mm)

PROTECTION CAP H +2 mm

Ø 3.6 H 5.5 mm

25 mm

20 mm

LABORATORY GUIDE SCREWS For straight and angulated abutments

Ø 3.6 mm

Ø3

TEMPORIZATION

TEMPORARY NON-ROTATIONAL ABUTMENT 20 N.cm

Ø 3.6 mm

APS CP 36 55

2

SNAP-ON IMPRESSION COPING Ø 3.6 H 5.5 mm

16 mm

For gold palladium and Esthetibase abutments

Ø 3.6 mm

APS TCP 36 55

SNAP-ON OPEN IMPRESSION COPING

NPS VG 16 160

h

1

NPS PA 30 07 1

3

NPS PA 30 07 3

APS H 36 55

3

Ø 3 mm

h (mm)

h NPS PA 30 15 1 NPS PA 30 15 3

h: supracrestal height (mm)

CAD-CAM CUSTOMIZED ABUTMENT Customized to your case and made by our CAD-CAM center Supplied with a fixing screw

FINAL RESTORATION

Supplied with a titanium fixing screw

3

H

H 5.5 mm

20 N.cm

1

SOLID ABUTMENT ANALOG Ø 3.6

h: supracrestal height (mm)

15° ANGULATED ABUTMENTS

Ø 3.6 mm

Ø 3.6 mm

BURN-OUT SLEEVES Ø 3.6 H 10 mm Non-rotational basis for APS BCO 36 100 single-unit prosthesis Rotational basis for multi-unit prosthesis

APS BCC 36 100

KITS Ø 3.6 H 5.5 mm Single-unit prosthesis

NPS KIT E05

Multi-unit prosthesis

NPS KIT EC5

H

Ø 3.6 mm

Supplied without abutment. A kit contains a protection cap, a snap-on impression coping, a snap-on open impression coping, an analog and a burn-out sleeve. Specify the abutment height and the prosthesis type (crown or bridge).

151

IV. Narrow implants

h (mm)

APS TCP 36

1

Supplied with a titanium fixing screw

Ø 3.6

2

20 N.cm

Ø 3 mm

Naturactis, Naturall+

7° ANGULATED ABUTMENTS

IMPRESSION

for adjusted abutments


ob

MINI-BALL IMPLANT Ø 2.7 MM

The OBI implant is a Ø 2.7 mm mini-implant made of grade V titanium indicated for the stabilisation of removable prostheses, thin crests, narrow mesio-distal spaces and temporary prostheses. Its placement is fast thanks to a simple surgical procedure: a single drill is necessary. Even though its dimensions are small, it has the same characteristics and thus the same guarantees of reliability as our traditional implants.

A reliable solution for totally edentulous patients n Suitable for thin crests. n An economical solution for patients who cannot afford traditional, expensive implants, or for patients who do not wish to undergo implant treatment requiring several operations.

Minimal spacing cases The implant is well-suited when  Ø 3 implants are too large for the available bone space.

h 6.5 mm

h 6.5 mm

A prime material h 1 mm

h 1 mm

n Made from medical grade V Titanium. n   Offers mechanical resistance adapted to the stress and diameter of the implant.

ø 4.3

ø 4.3

ø 5.2

A neat finish

h 2 mm

ø 2.9

Double asymmetrical thread

4

h 3 mm

e

0.3 mm 40° 7°

Real screw thread 1.60 mm

°/

h 2.8 mm

h 1.5 mm

7

ø 2.7

Thread 0.8 mm

n The flared neck provides an aesthetic emergence profile. n   The surface treatment of the implant creates 0.2 mm Ra circular pits which provides optimal adherence of the implant to the gingival fibres. n The rounded neck helps prevent irritation in the mouth.

OBI

40

Etching

bl

y as

Sandblasting

u

h 0.5 mm

ri c al t hre ad met

Commercial length

A flared, smooth neck

h 4 mm

Do

n The asymetric thread ensures the primary stability of the implant by preventing micromovements caused by masticatory forces n The 2 parallel helices reduce the risk of the bone overheating and the insertion time by half.

ø 3.5

h 4 mm

°

IV. Narrow implants

The same characteristics and the same guarantees of reliability as our traditional implants: asymmetrical thread, atraumatic rounded end, flared neck, surface state...

ø 2.35

A safe design n The double thread reduces heating upon insertion and allows the clinician to place the implant faster. n The vent on the apical end allows the implant to be engaged without over-compression (the bone fragments resulting from selftapping are contained in the vents). n The soft round end of the implant enables atraumatic placement

152


Implant references T60 grade IV pure titanium. Supplied on demand with a prosthetic part or an attachment.

Length «L»

Mini-ball implant Ø 2.7 h 6.8 mm

Mini implant /ball abutment Ø 2.7 h 8.5 mm

9 mm

OIC 27 68 090

OIC 27 85 090

11 mm

OIC 27 68 110

OIC 27 85 110

13 mm

OIC 27 68 130

OIC 27 85 130

15 mm

OIC 27 68 150

OIC 27 85 150

Compact surgical kit Ref. OICK 27 xx 00

Readibility of the sequences step by step presentation indications with arrows

ODG 20 35

Ø 1.5 - 2.2

CFP 15 22 50 OFI 20 150 NJP 18 250 OAP 19 29 100 CMO HI 25 26

short - 8 mm long - 16 mm

CCL HI 25 18 CCL HI 25 26

Click wrench Mandrel extension

CCC 120 CRM 340

Prosthetic range

NITRIDED TITANIUM ABUTMENT OPS PD 29 42 10

7.5 mm Emergence Ø: 4.3 mm

Ø 2,25 mm

ABUTMENT ANALOG Can be cut

BURN-OUT ABUTMENT OPS PC 29 42 75

7.5 mm

OPS HOBI

O’RING

4

Overdenture

Ø 5,2 mm

OBI

Cemented prosthesis

2 mm UPA FOR 52 Supplied with 3 different retaining rings Soft 50 shores

Medium 60 shores

Hard 70 shores

UPA JOR 50

UPA JOR 60

UPA JOR 70

Emergence Ø: 4.3 mm

Pictures for illustration purposes only

153

IV. Narrow implants

Gingival cutter Point drill Drill Ø 2 Depth gauge Paralleling pin Internal hexagon mandrel Internal hexagon keys:

CONTENTS OICK 27 xx 00


teknika

154


V. INSTRUMENTATION Torque wrench Point drills Surgical sequencer Prosthetic kits euroteknika common instruments Instruments for direct handling Instruments for implant-holder Extraction kits

156 157 157 157 158 159 159 160

VI. SYNTHETIC BONE SUBSTITUTE

155

V. Instrumentation

VII. PRODUCTS AND SERVICES


Torque wrench Made of surgical stainless steel. Detachable for easier cleaning. Different torque adjustments available : 35, 40, 45, 50, 55, 60, 65, 70 & 75 N.cm for the surgical torque wrench and 10, 15, 20, 25, 30, 35 & 40 N.cm for the prosthesis torque wrench. n Automatic stop: tightening stops automatically when the pre-set value is reached. n n n

1 - Surgery For placing implants in the surgical site.

Ref. CCC 70

With progressive torque adjustment every 5 N.cm, within the recommended range of 35 N.cm to 75 N.cm. The torque wrench can be used instead of a surgical motor when the surgeon prefers to insert the implant by hand or for motors that do not display the torque level. Allows accurate measurement of primary implant stability.

2 - Prosthesis For precision tightening of prosthetic parts.

Ref. CCC 35

If the prosthetic superstructures are not assembled with the recommended prestress (see user guides) the screw may come loose after a few solicitations. Furthermore, n a tightening torque too low will not create enough strain to absorb the stress suffered by the screw. n a tightening torque too high could damage the implant thread or deform the screw not allowing it to absorb the masticatory stress.

!

The torque values are indicated for permanent prostheses. In case of immediate loading, we recommend using a lower torque value and tightening to the definitive torque later on.

OPTION Adapter key for use with all implant systems (only for use on prosthetic systems with a torque of less than or equal to 35 N.cm).

Ref. CAD 115

Tightening to chosen torque

Functional play of threading

1. Placement of the screw

V. Instrumentation

2. Final tightening to the recommended torque

3. Final adaptation of the components = stable assembly

Functional play of threading

156


Point drills Ø 2.2

Ø 1.5 - 2.2 Ref. CFP 15 22 50

Ref. NFP 22 180

The upper part of the point drill is Ø 2.2  mm providing an easy start for the first turn of the drill. n The 90° cutting edge makes a clear and precise mark on the bone crest, even when the crest is thin. n

Ø 2.2 pilot for first twist drill Ø 1.5 mm

5 mm 2 mm

The upper part of the point drill is Ø 2.2  mm providing an easy start for the first turn of the drill. n

Ø 2.2 mm 8 mm

6 mm

90° cutting edge

Surgical sequencer This allows you to lay out the implants and instruments in the right order for a specific surgical procedure.

Ref. CSC 7 20 - Empty supplied

How to use the surgical sequencer:

2. Opening the implant packaging

4. Pick ing up the hea lin or the c g abutment over sc rew

{

1.

p

gu

3.

kin Pic

t

lan

mp

i the

Pockets for: implant packaging, paralleling pins, direct handling key, hexagonal keys, implant caps, depth gauges, extension mandrel, direct handling mandrels.

n n n n n n n n

First sequence of drills Second sequence of drills

Prosthetic kits

Pictures for illustration purposes only

157

V. Instrumentation

P6 00

Ref. TPK 00 P6

PK

Prosthetic kit with torque wrench Contents: Same contents as the kit ref. TPK 00 P4 with a torque wrench 10-40 N.cm (ref. CCC 35)

Ref. TPK 00 P5

f. T

Prosthetic kit with click wrench Contents: Same contents as the kit ref. TPK 00 P4 with a click wrench (ref. CCC 120)

Ref. TPK 00 P4

Re

Prosthetic kit Contents: External hexagonal key (ref. CCL HE 12 22) External hexagonal mandrel (ref. CMA HE 12 26) O’Ring internal hexagonal key (ref. CCL HI 25 26) O’Ring internal hexagonal mandrel (ref.CMO HI 25 26)


euroteknika COMMON INSTRUMENTS External hexagonal keys A key to do everything In order to make the prosthetic parts screwing easier for you, we have opted for a single external hexagonal key, available in manual or contra-angle version and allowing you to screw most of the prosthetic parts of our implant systems (trans-screwed abutments, solid abutments, short conical abutments…). However, it not suitable for the O’Ring, ConHex, Conica and Tetra abutments.

short Ref. CCL HE 12 18 20 mm 12 mm

8 mm

medium Ref. CCL HE 12 22

long Ref. CCL HE 12 30

O’Ring internal hexagonal keys

Internal hexagonal key

For O’Ring, ConHex and Conica abutments and Naturex and OBI implants.

For Tetra straight abutment.

short 16 mm 8 mm

Ref. CCL HI 20 24

Ref. CCL HI 25 18

long

10 mm

Ref. CCL HI 25 26

O’Ring internal hexagonal mandrel

For O’Ring, ConHex and Conica abutments and Naturex and OBI implants. 26 mm

For Tetra straight abutment. 26 mm

Ref. CMO HI 25 26

External hexagonal mandrels 22 mm

Internal hexagonal mandrel

short

Mandrel extension Use as extension for all drills and instruments that can be used with a contra-angle.

Ref. CMA HE 12 22 26 mm

Ref. UMA HI 20 26

34 mm

long

Ref. CRM 340

Ref. CMA HE 12 26

Adapter sleeve Ref. CAM 70 100

V. Instrumentation

Use to extend length of all mandrels.

Detachable click wrench Ref. CCC 120

4 mm square key for taps Ref. CEC 40 For tap manual use. Allows machine tap to be used with click wrench and torque wrench. 4 mm

4 mm

158


INSTRUMENTS FOR IMPLANTS WITH DIRECT HANDLING Direct implant keys L

Naturactis Naturall+ Natea+

For implants Naturactis Naturall+ Natea+

Aesthetica+2

Uneva+

Short - L 10 mm

CCP 35 20

CCP 42 20

CCP 24 20

Medium - L 15 mm

CCP 35 30

CCP 42 30

CCP 24 30

Long - L 20 mm

CCP 35 40

CCP 42 40

CCP 24 40

L Aesthetica+2 L Uneva+

Direct implant mandrels L

Naturactis Naturall+ Natea+ Aesthetica+

For implants Naturactis Naturall+ Natea+

Aesthetica+2

Uneva+

Short - L 20 mm

CMP 35 20

CMP 42 20

CMP 24 20

Long - L 30 mm

CMP 35 30

CMP 42 30

CMP 24 30

L 2

L Uneva+

INSTRUMENTS FOR IMPLANTS WITH IMPLANT-HOLDER Implant-holder keys short Ref. CPI 170 16 mm 7 mm

11 mm

medium Ref. CPI 210

long Ref. CPI 260

Implant-holder mandrels short 23 mm

Counter torque key For implant-holder for the entire prosthetic range. Ref. CAR 30 78

Ref. CMI 230

long 26 mm

Ref. CMI 280

Implant drivers

Implants

Ref. long

Ref. short

Naturall ø 3.5 / Natea ø 3.6 Naturactis / Naturall+ / Natea+

NDI 16 35

NDI 16 20

Naturall ø 4 - 4.5 - 5 / Natea ø 4.1 - 4.8 - 6 NDI 20 20

NDI 20 40

Naturex ø 3

NDI 14 30

NDI 14 15

Aesthetica+ (all implants)

ADI 48 55

ADI 48 25

Uneva / Universal+ (all implants)

UDI 20 50

UDI 20 25

Long : 15 mm Short : 10 mm

159

V. Instrumentation

The implant driver can be used directly in the implant connection after removal of the implant-holder. It is particularly useful for inserting or removing the implant.


NEW

euroteknika EXTRACTION KITS This extraction kit is a complete solution for mechanical complications encountered in implantology.

1 - Extract abutments blocked in the implant Abutments can be extracted without disturbing the implant thanks to an abutment extractor. 2 - Extract a screw broken in the implant n Use the drilling guide and high-power carbide drill to cut the titanium, make a small opening in the remaining piece of the screw. n A self-locking extractor is then inserted into the piece of broken screw so it can be unscrewed. n A screw tap enables the thread to be modified if damaged. 3 - Extract an implant The implant can be unscrewed with a self-locking extractor. The bone around the implant can be cut using trephines which match the diameters of the different implants.

n n

1

2

3

References of kits and supplements

OPTIONS / SUPPLEMENTS

V. Instrumentation

Naturactis Naturall+ Natea+

KITS

Naturactis Naturall+ / Natea+

Ref. KDR 3N

Aesthetica+ Aesthetica+2

Ref. KDR AEST

Naturex

Ref. KDR NAT

Uneva / Uneva+

Ref. KDR U

Naturall Natea RP & WP

Ref. KDR N RP WP

Aesthetica+ / Naturex Aesthetica+2

Ref. KIR AEST

Ref. KIR NAT

Uneva / Uneva+

Ref. KIR U

Ref. KIR 3N

160

Picture for illustration purpose only

Ref. KIR AEST

Ref. KIR NAT

Ref. KIR U

Naturall Natea RP & WP

Ref. KIR N RP WP


Content of extraction kits and supplements KITS REFERENCES

KDR 3N

KDR AEST

Abutment extractor M1.6

CEP 16 175

Abutment extractor M2

CEP 20 175

Reverse drill Ø 1.2

CFK TG 12

X

Drilling guide Naturactis / Naturall+/ Natea+

CGK 3N

X

Drilling guide Aesthetica+ / Aesthetica+2

CGK AEST

Drilling guide Naturex

CGK NAT

Drilling guide Uneva/Uneva+

CGK U

Drilling guide Naturall/Natea RP and WP

CGK N RP WP

Tap M1.4

CTK TA 14

Tap M1.6

CTK TA 16

Tap M2

CTK TA 20

Screw extractor

CCK QV 15 150

X

X

Implant extractor / narrow

CCK QI 11 150

X

X

Implant extractor / large

CCK QI 15 150

X

Trephine Ø 3.8

CMK TR 38

Trephine Ø 4.6

KDR NAT

KDR U

X

KIR 3N

KIR AEST

KIR NAT

KIR U

KIR N RP WP

X X

X

X

X

X

X

X

X

X X

X X

X X

X X

X

X

X

X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

CMK TR 46

X

X

X

X

X

Trephine Ø 5.3

CMK TR 53

X

X

X

X

X

Trephine Ø 6.7

CMK TR 67

X

X

X

X

X

X

X

X

161

V. Instrumentation

DESIGNATION

SUPPLEMENTS KDR N RP WP


SYNTHETIC BONE SUBSTITUTE Macrobone is a high porosity synthetic bone substitute (around 90% porosity) designed for filling bone defects during dental and maxillofacial surgery. It is made from pure tricalcium phosphate (ß-TCP) which is completely and rapidly resorbable.

n Macrobone is fully synthetic; there is no risk of infection or immune response. n Due to its composition, Macrobone is biocompatible, osseointegrable and resorbable. n The TCP granules are radiopaque, so cavity filling and graft integration can be monitored using x-ray imaging. n The shapes of the Macrobone granules solve problems related to filling irregular-shaped cavities. n Macrobone reduces the need for autologous sampling and surgery time.

Composition Macrobone is made from pure, resorbable tricalcium phosphate (ß-TCP) which is a bioactive calcium phosphate salt. It is biologically more soluble than hydroxyapatite and very similar to the mineral phase in human bone. Totally resorbable, it is replaced within 6 or 7 months by neo-formed bone.

Histology and clinical studies THE INSERM in Angers (France) has carried out studies on osseous carrots taken at D+3 months from a Macrobone-filled sinus. All the results showed the same aspect of osseous remodeling. The picture opposite shows the perfect apposition of the bone on the biomaterial thus confirming osseointegration. Macrobone has benefitted from 7 years of clinical studies.

Colour: Goldner’s Trichrome : Granule limit Direct apposition of the bone on the surface of the bone substitute

Porosity

Magnification x250

The total porosity of Macrobone is close to 90 %. It is composed of:

VI. Macrobone

n   a macroporosity made of large size pores (from 0.2 to 0.5 mm) some of which are interconnected with the others (see picture opposite) thanks to which the bone can penetrate into the heart of the material (osseointegration by osteoconduction). n   a microporosity.

During the Macrobone osseous remodeling process, the osseous cells split up and digest the biomaterial while making new replacement bone tissue. The high porosity limits the presence of biomaterials to 10 % with regard to its global volume. The transformation process is thus faster and cells progress more easily. High porosity 90%. INSERM U922 Angers (Pr D. Chappard)

162


Range & Indications

1

3

2

Granulometry 150-500 µm (0,15 to 0,5 mm) Indications: periodontology

Granulometry 500-1000 µm (0,5 to 1 mm) Indications : cavity filling, filling of medium size bone defects

Granulometry 1000-2000 µm (1 to 2 mm) Indications : sinus lift

Clinical case - Dr Bernard Guillaume (Paris - France)

Aspect of the sinus before the graft

Bone substitute with ßTCP: Scan at 1 month

Bone substitute with ßTCP after 10 months

Aesthetica+ Implant

Retro-alveolar X-Ray screening

Prosthesis in place

Packaging and references Macrobone is packaged in a box in 2 individual sterile wells (double sterile

PACKAGING Granulometry

2 wells x 0,5cc

2 wells x 1cc

150-500 µm

ref. BON 15 50 052

ref. BON 15 50 102

500-1000 µm

ref. BON 50 100 052

ref. BON 50 100 102

1000-2000 µm

ref. BON 100 200 052

ref. BON 100 200 102

163

VI. Macrobone

packaging).


PRODUCTS AND SERVICES

teknika

NEW

YOUR euroteknika TABLET AND ITS APPLICATIONS

+

+

+

Nts

R

Nta

O

Ntl

D

2

+

Ata

N

Una

Une

G

P

Ntx

Obi

C

Store

In order to continue providing you with more tools and aids to help you in your day-to-day work, euroteknika has developed new applications which have been installed on a Samsung tablet. You can consult all our euroteknika media on your tablet: user guides, surgery kit storage guides, euroteknika clinical cases, developments and new products, patient documentation…. You will be able to update the applications in one click via the euroteknika store.

ORGANIZATION

P R O S T H E S I S

C H E C K

A F T E R

PROBLEMS

S TA G E :

T H E

P R O ST H E S I S

P L A C E M E N T

POSSIBLE REASONS

II. Removal of continuation

SOLUTIONS 1. Stop the prosthesis stages Leave the implant without loading for 2 additional months. Test it again and repeat the prosthesis stages. 2. Cut the span, take a key make a primary soldering and in the laboratory. Fitting of the span. Unscrewing of one or Screw again, with more prosthesis screws new screws and Occlusion problem. a dynamometric torque during the first check wrench by at Uncalibrated screwing. respecting the tightening 15 days. torque, check the occlusion, and check again after 15 days. 1. Check the occlusion or control the adjustment and / of the Unscrewing of the 1. Occlusion problem trabecula. or prosthesis screws wrong adjustment 2. Reduce the extension. of the during the second trabecula. Change the design of the control or late 2. Too large extension, prosthesis (add an bad implant etc.). unscrewing. design of the prosthesis. 3. Screw, with new screws and a 3. Uncalibrated screwing. dynamometric torque wrench by respecting the tightening torque, check the occlusion, and check again after 15 days. Check the adjustment of the abutment onto the implant with a Abscess facing an retroalveolar X-Ray. Wrong adaptation of the implant. Remove the abutment, abutment on the implant. it, remove the granulationsterilize tissue, disinfect with a chlorhexidine solution, place again the abutment. Pains after the Use a new screw. Osseo-integration placement of the loss of an implant. Remove the implant. prosthesis. Peri-implant infection. See below. Fracture of the resin Problem of occlusion or bruxism or parafunctional ceramic. Extract from Check the occlusion. the book patient. Make up an occlusive «Decision-making denture. in Pain feeling during the 1. Implant with screwing of a screw an imperfect (for osse-ointegration. the fitting of the span or the placement of the 2. Wrong adaptation of the prosthesis). trabecula.

Complications management guide Short presentation of the different complications the practitioner may face in implantology and the most suitable solutions to resolve these situations.

Fracture of the frame.

Too thin metal reinforcement and / or too large prosthetic extension. Patient with bruxism.

IONS C O M P LI CAT gui de ma nag em ent 4

III. Removal of an implant Step 1

Use the implant

extractor.

1. Insert the extractor into the connection 2. Turn counterclockw of the implant to be removed. 3. Use counterclockw ise to grip the implant by applying pressure ise the click-wrench the implant. on the extractor head thereon. to unscrew 4. Once the thread is taken in the material, from the site. unscrew the implant to break it away 5. Extract the implant by unscrewing it with the extractor. Step 2

If the extractor implant did not work (after step 1). 1. Choose the trephine 2. Place the trephine according to the implant diameter. on the contra-angle. 3. Adjust the motor speed according to the trephine diameter. 4. Grind around the implant, taking into account the working be inferior to the implant length. length that should 5. Extract the implant with dental forceps with twisting and bending movements.

implant practice» Frank RENOUARD of & Bo RANGERT Quintessence International.

Make the prosthesis by modifying the design (adding an implant, deduction or elimination of extensions, reduction of of the occlusive surface, the width reducing of the inclination of the cusps, etc.). Make up an occlusive denture.

a broken screw in the implant -

Step 3

If the implant thread is damaged (after step 1 or step 2). 1. Lubricate the tap with food grade lubricant. 2. Hand-screw the tap in the axis of the part 3. Remove the tap manually by unscrewing without forcing. 4. Clean the thread and remove the formed at the first effort. 5. Repeat these operations chips. until the end of 6. Try a new screw (screw without effort). the thread.

The further recommendations from euroteknika are shown in italics.

To get more information about these extraction please contact your sales advisor kits, or euroteknik +33(0)4 50 91 a 49 20.

9

T L IM PLAN A G LOBA

SOLUTION

France eurote knika SALLANCH ES, 98 66 De Gaulle - 74700 : 33 (0)4 50 91 726 rue du Général 91 49 20 - Fax

50 Tel : 33 (0)4

a.com www.euroteknik

Notre gamme d’implants

bénéficie de la marque

CE, conformément

à Directive Européenne

ications_0114_GB

- N° CE 0499 - Fiche-gestion-compl

Organizational documents

PRE-IMPLANT MEDICAL QUESTIONNAIRE Answer carefully, delete as appropriate SURNAME

GIVEN NAME

Your age :

Your size :

Your weight :

Your blood pressure:

Your doctor :

All the necessary documents to rationalize the operation:

Address : Phone number : 1 - Are you healthy?

3 – Are you followed by a doctor?

n   Medical questionnaire n   Informed consent n   Quote template n   Statistical form n   Template for prescription for a scan

Yes

No

Yes

No

2 – Date - of your last visit to the doctor - of your last health check-up 4 – Do you have any allergies?

Yes

No

5 – Do you have any allergies to medications?

Yes

No

6 – Did you have any serious illnesses?

Yes

No

Yes

No

Yes

No

- If Yes, which ? 7 – Do you take any medications? 8 – Date of your last visit to a dentist 9 – What care did you receive? 10 – Do you tighten or do you grind teeth? 11 – Did you have an occlusal adjustment?

Yes

No

12 – Do you have any trouble to open wide your mouth?

Yes

No

13 – Do you have pain in the ears?

Yes

No

14 – Did you have gingiva diseases?

Yes

No

15 – Did your gingiva undergo care?

Yes

No

16 – Did you have orthodontic treatment?

Yes

No

17 – Did you have any sinus problems?

Yes

No

18 – Have you lost weight or got fat for 1 year?

Yes

No

19 – Have you been ill in recent months?

Yes

No

20 – Have you been hospitalized for 1 year?

Yes

No

21 – Do you have an operation (even long ago)?

Yes

22 – Have you been transfused?

COACHING Organizational Documents

IMPLAN

Yes Yes Yes

No

Yes

No

Yes

No

- Hepatitis ?

Yes

No

- Breakdown ?

- Tuberculosis ?

Yes

No

- Glaucoma ?

Yes

No

- Coma ?

Yes

No

- Ulcer ?

Yes

No

- Epilepsy ?

Yes

No

- Polio ?

Yes

No

- Acute rheumatoid arthritis?

Yes

No

- Diabetes ?

Yes

No

- Eczema ?

Yes

No

- Heart attack ?

Yes

No

- Prostatic disorders ?

Yes

No

- Other diseases, which?

IMPLANT

3,6 - 4,2

I M PLANT

4,2 T 3,6 -

3,6 - 4,8

4.8

E ECHELL S C A L E 1,7/1

4.2

30

ECHELL S CALE 1/1

30

0,52

20

IMPLAN

4,8 T 3,6 -

E

4.2

4.8

4.2 0,52

4.8

10

mm

IMPLA N° CE 0499

6.5

20

6.5

10 4.8

4,1 - 4,8 IMPLANT

- 4,2 NT 4,1

mm

1201

4.8

/ TC_AESA-1.0-

N° CE 0499

1201

/ TC_AESA-1.7-

4.2 0,52

IMPLAN IMPLAN

4,8 T 4,1 -

4,2 T 4,1 -

4.8

4.2

0,6

0,6

IM PLAN IMPLA

0,6

IMPLAN IMPLAN

4.8

6.5

0,71

0,71

0,71

Natea+ protocol by bone density and implant diameter

natea

IMPlants Ø 4.1

IMPlants Ø 3.6 lenght 8 - 10 - 12 - 14 mm Point drill Drill Ø 2.2 with stop

D2/D3 Ø3

lenght 8 - 10 - 12 - 14 mm

D1

D4 Ø 3.3

Drill 1200 rpm

  800 rpm

Ø 3.5/4.1

Ø 3/3.6

Ø 3.5/4.1

Ø 3.5/4.1

400 rpm

Ø 3.6

or

Ø 4.1

For D1

optioNal

Drill

taPs

Example of insertion for a 10 mm long implant, the same as for the other lengths of implants.

25 rpm

or

Ø 3.8

Ø 3.3

25 rpm

800 rpm

option

800 rpm

option

from 15 to 25 rpm

Ø 3.6

Ø 3.6

Ø 3.6

Ø 4.1

Ø 4.1

Ø 4.1

!

Attention, the protocol for a 6 mm long implant is different.

Management of bone quality Soft bone D4 To enhance primary stability, the implant socket is 0.8 mm undersized compared with the implant diameter. The whole thread is compressed in the bone.

implant socket thread tops

164

D1

Ø 3.5

cortical Drill

Ø 3/3.6

400 rpm

These laminated protocols provide a recap of the various stages of the surgical procedure for the implant according to the bone quality. These protocols are available for each implant range.

D2/D3

800 rpm

Ø 3/3.6

iN SubStitutioN

VII. Services

D4 Ø 2.8

 

1200 rpm

6,5 T 4,8 -

- 4,8 NT 4,8

6.5

6,5 T 4,8 -

4,8 T 4,8 4.8

Laminated Protocols

No

- Jaudnice ?

4.2

Surgery transparencies

No

23 – Did you have a X-Ray or chemotherapy? 24 - Are you often tired or irritable? 25 – Did you have the following diseases or conditions?

A global solution FOR IMPLANTOLOGY

These transparencies can help the practitioner find the most suitable implant length and diameter for their clinical cases. They are available for each implant range.

No

- What was this intervention?

0.4 mm

Better stability

Normal bone D2 - D3 The implant socket is 0.6 mm undersized compared with the implant diameter. The thread is compressed in the bone until its basis to ensure a good primary stability. implant socket thread tops

0.3 mm


t is on solid abutmen Cemented prosthes

API 42 85

Supplied with a fi

VG 20 140)

N COPINGS POP-UP IMPRESSIO (ref. APS VTB 20 174) a fixing screw

VT 20 154)

Can be cut

Different colors according

to the version

Plastic - Supplied (ref. APS VG 20 140)

TION FINAL RESTORA

15° 20°

fixing screw (ref. APS

Supplied with a titanium

For For straight abutment 15° & 20° angulated NonRotational abutment rotational APS CA CCC APS CCO APS 42 47 42 55 42 55

H 10 mm APS PR 42 100

APS CCC 48 55

APS CA 48 50

APS CCO 65 55

APS CCC 65 55

APS CA 65 70

Size L - Supplied Ø

ABUTMENTS 35

with a titanium

APS H 65 40 APS H 65 55

APS H 48 40 APS H 48 55

TEMPORIZATION

9 mm

4 5.5

------

APS H 48 70 to the version Different colors according

7

CUSTOMIZE D ABUTMENT

APS PR 65 120

APS PR 48 150

ESTHETIBAS E

case and Customized to your center made by our CAD-CAM Supplied with a fi (ref. APS VF 20 93)

N.cm

VF 20 93) fixing screw (ref. APS

4.65 mm Ø 6.5 Ø5 Ø 4.3 48 APC PTO 65 PTO 42 APC PTO Non-rotational APC 65 PTC 48 APC PTC APC PTC 42 APC Rotational

xing screw

Ø

Ø

Ht (mm)

BURN-OUT SLEEVES

Ø

VF 20 112)

Ø

APS CCO 48 55

ANALOGS

Can be cut

3

APS PS 65 100

APS PS 48 100

SOLID ABUTMENT

N.cm ABUTMENTS 35

titanium Supplied with a M2 VF 20 70) fixing screw (ref. APS

35 N.cm

ABUTMENTS CUSTOMIZABLE

BURN-OUT SLEEVES

GOLD PALLADIUM

H 6.5 mm

APS PA 65 15 APS PA 48 15 APS PA 65 20 APS PA 48 20

Single use For adjusted abutments

TCP 65 40 APS TCP 48 40 APS APS TCP 65 55 TCP 65 Ø 5.5 APS TCP 48 55 APS TCP 48 APS -----APS TCP 48 70 7 to the version Different colors according

4 ETK AE WPSB

TION FINAL RESTORA

H 6.5 mm

Ø

SNAP-ON OPEN IMPRESSION COPINGS

H (mm)

ETK AE RPSB

ETK AE NPSB

H

------

APS CP 48 70

8.8

fixing

VF 20 112)

CP 65 40 APS CP 48 40 APS CP 65 55 APS CP 48 55 APS

7.2

SNAP-ON IMPRESSION COPINGS

Single use

H 10 mm

Supplied with a titanium

35 N.cm

fixing screw (ref. APS

APS PD 65 55

APS PD 48 55

H (mm) 5.8

35 N.cm

Supplied with a titanium

PROTECTION CAPS

2

ON IMPLANT

with a fixing screw

ANGULATED ABUTMENTS screw (ref. APS VF 20 70) STRAIGHT ABUTMENTS

------

APS PP 48 70 to the version Different colors according

7

ETK AIEP PO

SCANBODY DIRECT

For gold palladium and Esthetibase abutments NPS VG 20 160

ALA H65

ALA H48

ALA H42

Ø mm

T 48 APU T 65 APU T 42 APU to the version Different colors according

BITE REGISTRATION ABUTMENT

APS VG 20 140

LABORATORY GUIDE SCREW

Ø

IMPLANT ANALOGS

Supplied with cap for pick-up technique and an impression

3

xing screw (ref. APV

Ø APE T65 APE T48 to the version Different colors according

APE T42

Ø

API 65 85

API 48 85

5.5

H 10 mm

xing screw (ref. APS

H 9 mm

POP-IN IMPRESSIO Supplied with a fi

IMPRESSION

These panoramas enable you to see, at a single glance, the different prosthetic options available according to the diameter of the implant inserted and the type of prosthetic construction (cemented, screwed or removable). Prosthetic panoramas are available for each implant range.

LABORATORY GUIDE SCREW

N COPINGS

PICK-UP IMPRESSIO

N COPINGS

2

H PP 65 40 APS PP 48 40 APS PP 65 55 APS PP 48 55 APS

4

IMPRESSION

4.5

ACI 65 72 45

16 mm

Prosthetic panoramas

ACI 65 43 00

ACI 48 35 00

35 N.cm

H (mm)

Ø 4.3

Ø 3.5 H

ACI 65 72 20 ACI 65 72 30

ACI 48 55 30 ACI 48 55 45

ACI 42 47 30 ACI 42 47 45

3

------

------

------

2

Ø 7.2

ACI 48 55 15

ACI 42 47 15

1.5

Ø

SOLID ABUTMENTS

10 N.cm Ø

Ø 5.5

Ø 4.7

H (mm)

COVER SCREWS

H 14 mm

TEMPORIZATION

1

1

abutment

10 N.cm

HEALING ABUTMENTS

H

ewed is on trans-scr Cemented prosthes

Ø

APS BCO 65 70 APS BCC 65 70

APS BCO 48 100 APS BCC 48 100

Non-rotational Rotational

Ø

KITS

H 4 mm

H 7 mm

H 5.5 mm

H 4 mm

H 5.5 mm

APS KIT L05 R07 APS KIT L04 KIT R05 APS KIT APS KIT R04 APS APS KIT LC5 Single-unit prosthesis RC7 APS KIT LC4 KIT RC5 APS KIT APS KIT RC4 APS Multi-unit prosthesis coping, a snapcap, a snap-on impressionthe abutment abutment, a protection Specify A kit contains a solid and a burn-out sleeve. coping, an analog on open impression type (single or multi-unit). height and the prosthesis

PATIENT RELATIONSHIPS

NCE

T ADD

PATIEN

RÉ Surgery completed by: RQUE MAName: DATE SITE

Leaflet (closed gate format) providing your patients with the exact references of the implants inserted for a better follow-up.

DENTIST

RESS

Last name:

T CONTAC

First name:

name:

Professional card number:

Last Birth date:

Prosthesis completed plete by: d by: com Surgery Name:

Address: date: Birth

Name:

e: First nam :

Address

ber:

num Professional card number: l card

Phone:

ona Professi by: pleted is com Prosthes

Name:

CE DE PIÈ TYPE HÉTIQUE PROT

DE TYPE ION EX CONN PATIENT ADDRESS UE UR

T I E N D PAT CAR

N° CE 0499 / CP-G B_1301

FÉRE

LONG

Ø

N° LOT

PAT I E N T CA R D

N° CE 0499 / CP-G B_1301

Patient card

DENTIST CONTACT

Phone:

France CHES SALLAN a.com - 74700 l De Gaulle 20 www.euroteknik 49 du Généra 726 rue +33 (0)4 50 91 Tel:

726 rue du Général De Gaulle - 74700 SALLANCHES - France Tel: +33 (0)4 50 91 49 20 www.euroteknika.com

number: l card

ona Professi

Operative report Pre-implanta euroteknika,

PLE-IMPLANTATI

logy for implanto a global solution

tion investigation

ON MEDICA L QUESTIONNAIRE

Last name First name Your age Your family doctor

Your height

Your weight

Address Phone number Date of your last visit to a dentist Date of your last visit to a doctor Date of your last health checkup Do you currently take any drugs or medications? If yes, what are they, and for what treatments. (List them all, do Have you ever had

If yes, what were

Patient

Patient records

yes

SURGICAL KIT

Reference / name:

Impression

OTHER

Birth date: Address:

Loading

Phone: responsible

no

Are you at risk of atherosclerosis? If yes, do you take anticoagulants? Does your blood yes no have difficulty coagulating? Do you have any yes no blood diseases? Do you have any yes no blood diseases? Do you have high yes no blood pressure? yes If yes, has it been no balanced by your treatment? Do you have a serious or graft-related immune deficiency? Have you ever had yes no a blood transfusion? Are you diabetic? yes no yes If yes, is your diabetes no insulin dependent? Is your diabetes balanced yes no by the treatment? What is your usual yes no blood sugar level? Do you have vitamin-D yes no deficiency? Do you suffer from severe hormonal or kidney disorders? yes no Have you ever had any of the following diseases or disorders? yes no Jaundice yes no Hepatitis Tuberculosis yes no yes no Depression yes Glaucoma Duodenal / ulcers no yes no yes no Prostate problems Coma yes no Diabetes yes no Acute rheumatoid yes no arthritisu yes Eczema no yes Asthma no yes no Anaemia yes Epilepsy Have you ever had no yes radiotherapy or chemotherap no Polio yes y? Have you ever had no cervicofacial radiotherapy? yes no Do you have, or have you ever had, viral yes hepatitis? no If yes, which one? yes no Have you ever had cold sores? Are you HIV-positive yes no or have AIDS? yes no

tation Instruments Implan used

First name:

ioner 10 Practit follow-up:

no no

no

disease? If yes, what kind? yes

Last name:

/ / /

yes

they and when?

Do you have heart

FILE

To ensure a good traceability of the implant treatment plans and operations. It is also a guide to remind practitioners of the main elements which contribute to the success of the treatment (pre-implant studies, information about implant placement and prosthetic stages...). The patient records will enable you to track the placement of the implants as well as the placement of the prosthesis.

/ / / yes

not omit any.)

surgery?

for

card number: Professional

3

U SSE

WHAT ARE THE BENEFITS OF DENTAL IMPLANTS?

TESTIMONIES

n t … D E N TS pla O S ld ique, 48Vyears-o DominV L’ i m E R E

• Improved comfort and quality of life Chewing efficiency

PR

As they are fixed into the jawbone, implants offer you reliable stability, giving you back the same sensations as with natural teeth. You eat better, enjoy more foods, with better nutrition.

ET

Natural speech Since they leave the palate totally free, implants let you speak naturally. • Aesthetics A natural look A dental prosthesis fixed onto an implant offers a better aesthetic result compared to a natural tooth. Invisible Implants let you smile, laugh or yawn with no discomfort, without running the risk of showing the hooks or metal parts of your denture. • Long-term restoration Security Dental implants have been shown to be a proven technique with a success rate of over 98%. Durability

S

IM

N OFS AYOUR TEETH ARE MISSING?

rt from and I had discomfo had Since I’ve perdue s was painful anyt «My prosthesi and when I did sport. longer haveden ne no défaut heat and cold in, it’s wonderful, I ent d’u put qui, à en an implant !» placemprothèse intenue of these problems ma ts, le rem

reil amov Appahets) (croc

ible

e collé

Bridg

Fonte

Proth

èse scell

ée

AV

EC

osse

use

T AN PL IM

globa ls -A o

gy - e ur olo nt

p u

If you practice good oral hygiene you can keep your implants for many years.

Patient leaflet

L O P I TA CA RE T AN V O TONE OR MORE PL

ÉS

ne ment, tion d’u ine, était de croche x e rac lisa deu onnelle Traditi par la réa er sur une soit à l’aidDans les ins s, mo passaitvoir s’appuy ts voisine schéma). plus ou ir à ament de pou par les den ent” (vo ration e ts ent tem détério ld croche s impliqu bouche “chapo une les ine les 79 years-o par ts ; pos aits, den ts vois De plus, si soit supJacque le.teeth! t aus ces des denalab cela , de ent ven cas pré all my I do have years ntes. Il 10 doi terme rec ouvrem more, buts au For thè overse, not 20 any tail2lée long «I’m importa telle et le I have implants. nt thought.sImplants t la pro them, a second soiegiven plu solution une themtan this t ci l’émail, Among por me, ires portan les- I haven’t teeth. atoFor ts sup celnow, care than more den que mastic ts sup des no s need den best!» es les racine r isà the e des forc eus perdre te oss résiste uent de de fon ttre son est fréq cessuscompromeosseuse se. t un pro prothè dent, se et peu résorption ien, il est de anc d’une thè perte s la pro A un stalddeement est s, le volume Dès la e souAnne, 33e.years-o term l’édent implant s’amorction à long lorsque er des sant. was dire de pos jaw, suffiimplant adapta , c’est-à- cile lower plus an so as not to in myant lost a tooth n’ét a bridge, I diffi e avancént«Since avoid having The surgical procedur plus way anctorer the only r lesmy 2 adjacent teeth. Now I can eat, chew d’auta pou damage and painless. osseux was very simplecomfort!» with and smile due ine per une rac artificielle placer ine aux à rem cette rac ourir t sis te s rec knika gro te ie con lle, et c’es se, san ctes. o nto log ficie prothè s, inta vée L’im pla racine arti ent la lem Fren préser Man ufac ch par uneporte tota sont ainsi turin e. g sup qui eus qui vible on oss voisines dents se amo énérati Ask your doctor la régfor advice prothè vec des ule une r qu’a t stim ime ilise sations de rég L’implan t de stab euroteknika permetten mêmes senuièrent pas s r les s ne req lantGaulle 726 rue du Général De Les imp s restitue implant 74700 Sallanches vou Les France et de relles. lier. natu Phone: 33 (0)4 50 91 49 20 dents aire particu www.euroteknika.com aliment

X

I M PLANTS ARE THE SOLUTION!

n for imp tio la lu

DP_GB_0114

Leaflet providing the patient with a simplified explanation of the implant treatment and its advantages compared to traditional options.

LO O K F O R IMPLANT !

Waiting room poster A global solutio n FOR IMPLANTOLO

GY

Alternative possibilit

y to bridges or stabilization of a removable prosthes is, implantology enables you to keep a maximum quantity of healthy natural teeth and available bone. Moreove r, implantology restores to the teeth a function closed to natural one (masticatory efficiency...). You will forget that you have.... an implant.

‘‘

euroteknika dental

implants are Class

IIb medical devices.

O N E I M PLANT

ON E TOOTH

They are standard to applicable norms especially EN1642/ISO14801 It is necessary to carefully /ISO5832-2/ ISO5832-3 consult the instructions and are manual and user guide relating to euroteknika not refunded by Health Insurance. They receive CE0499 implant systems. mark issued

poster_pa tient_etk_ G B_03 13

Laminated poster to hang in reception or in the waiting room at your surgery (size: 297 mm x 420 mm).

‘‘

by SNCH.

FOR YOUR REFERRALS CEMENTED PROSTHESI S ON TRANS-SCR EWED ABUTMENT NARROW PLATFORM

Update : 01/14

2

Quantity to be ordered

CEMENTED PROSTHESIS ON TRANS-SCRE WED NARR OW PLATF ABUTMENT ORM

H 2 : UPS PD 46 20 Ø 4.6 mm

Angulated abutments 15° & 20°

References H 1 : UPS PD 46 10

Straight abutments H

These forms will help your referrals to select and order the parts you need for your prosthetic constructions. These forms are available for each implant range.

np Ø 4.6

- 6 on emergence switching 1

Visual

H 3 : UPS PD 46 30 15° : UPS PA 46 15

H1 Ø 4.6 mm Ø 4.6 mm

Gold palladium abutments

aesthetica

20° : UPS PA 46 20

Visual

Hexagonal : UPS BSH 46 10

Straight titanium abutment

Cylindrical : UPS BSR 46 10

H1 Ø 4.2 mm

Burn-out abutments

Hexagonal : UPS PHC 42 10

3

Cylindrical : UPS PRC 42 10

H1

1

15° : APS PA 48

15

20° : APS PA 48

20

2

H 10

APS PS 48 100

UPS H 37

Customizable abutment Pick-up impression coping

H 10

APS PR 42 100

UPS TCO 50

Ø 4.2

Ø 4.6 mm

Pop-in impression coping

Pick-up impression coping

H 8.5

APE T42

BILLING ADDRESS Pop-in impression coping

UPS TCU 50

Doctor : Address :

Ø 4.1 mm

Non-rotational UPS PT 41 100

10 mm

Ø 4.1 mm

Laboratory guide screw for straight & angulated abutments

Rotational : UPS PTR 41 100 Lg 8 : UPS VG 20 80 Lg 12 : UPS VG 20 120

Laboratory guide screw for burn-out abutment & gold palladium abutment

Lg 10 : UPS VG 20 100 Lg 15 : UPS VG 20 150 Lg 20 : UPS VG 20 200

Esthetibase abutments

Orientable : UPC PTO 41 Ø 4.8 mm

Cylindrical : UPC PTC 41

3

4

Ø 5.1

UPS TCF 50 Ø 4.5 mm

Pop-up impression coping

Direct temporary abutments

2 Update : 01/14

Quantity to be ordered

APS PD 48 55

H 6.45

Gold palladium abutment

Ø 4.1 mm

Implant analog

References

H 5.5

Angulated titanium abutments 4 15° & 20°

Tel. : E-mail :

API 42 85 Ø 4.2

Pop-up impression coping

APU T42 Ø 4.2 Ø 4.2

DELIVERY ADDRESS Implant analog (if different from the billing address)

ALA H42

Doctor : Address :

Laboratory guide screw

BILLING ADDRESS H 14

APS VG 20 140

Tel. :

Bite registration abutment 726 rue du Général De Gaulle 74700 Sallanches - France Tel. : +33 (0)4 50 91 49 20 Indexable Fax : +33 (0)4 50 91 98 66 burn-out sleeve sales@euroteknika.com for single crown www.euroteknika.com on straight abutments Cylindrical burnout sleeve for bridges on straight abutments

Doctor : Address :

H9

ETK AIEP PO

Ø 4.2

Ø 4.2

Burn-out sleeve for angulated abutments 15° & 20° Ø 4.2

Esthetibase abutments Ø 4.3

APS CCO 42 55

Tel. : E-mail : DELIVERY ADDRESS (if different from the billing address) Doctor : Address :

APS CCC 42 55 Tel. : APS CA 42 47 Orientable : APC

PTO 42

Cylindrical : APC

PTC 42

726 rue du Général De Gaulle 74700 Sallanches - France Tel. : +33 (0)4 50 91 49 20 Fax : +33 (0)4 50 91 98 sales@euroteknika.com66 www.euroteknika.com

165

VII. Services

Order forms

For implants Ø 3.6 - 4.1 or Ø 4.8


teknika

YOUR TRAINING PARTNER teknikatraining offers training to dental professionals wishing to integrate oral implantology into their general practice.

CONFERENCE DAYS These sessions are led by renowned specialists, and allow you to develop your general knowledge of implant technology while meeting other practitioners in your region. Admission to these conference days is free.

INTERNATIONAL TRAINING

Our goal is to help you seamlessly acquire oral implantology by providing you with the experience and support of our pedagogical team, which is made up of 23 teachers specialised in implant technology. We offer a wide range of training in a friendly atmosphere, led by dedicated and available renowned experts, who place great emphasis on teamwork and the sharing of information.

COMPLETE IMPLANT TECHNOLOGY CYCLE

CLINICAL ACCOMPANIMENT More than training: real action! Learning a skill is one thing, but actually applying it is another, and the transition can be difficult‌ our clinical accompaniment programme is here to help you get your start! A euroteknika tutor accompanies you at the different stages of implant treatment, in which you become more and more involved until you become completely autonomous.

The complete Implant cycle is a 5-stage, 2-day training program with both theoretical and practical topics presented incrementally, in order to provide all the bases and knowledge needed for implant work, from planning the implants to advanced surgery. Each stage is composed of a practical work session on training models or animal jaws, as well as direct surgeries.

These international training sessions offer practical training in implant technology through surgery on patients, allowing you to acquire new techniques, and to share experiences with international implant technology practitioners, all while enjoying a trip abroad.

SPECIALISED TRAINING Short training sessions lasting one or two days allow you to acquire the theoretical and practical foundations needed to get your start in implant technology, as well as the chance to fine-tune your knowledge with advanced training sessions. These training sessions are available all over France.

COMPLETE PERIODONTOLOGICAL CYCLE The complete periodontological cycle is a training programme consisting of 4 sessions over 2 days, which combines theoretical learning and practical efficiency to allow you to master all periodontological cases.

A MODERN TRAINING CENTER More than 300 m² dedicated to training, in the heart of Mont-Blanc valley: n one surgery room equipped with video transmission,

VII. Services

n one conference room for 48 persons, n one room for workshops for 36 persons, n one educational team of 23 professionals.

166


DIGITAL & GUIDED SURGERY PARTNER

PRE-IMPLANTATION PLANNING teknika3D software with 3 functions n 3D bone volume reconstruction from the scanner DICOM pictures. n Planning that allows an optimal implant positioning. n The creation of the guide.

teknika3D is an exclusive entity specialising in digital implantology solutions. Computer-aided implantology has shown indisputable results in terms of performance and efficiency.

GUIDED SURGERY Complete guided surgery n Specific instrumentation. n Dedicated implants. Simplified guided surgery n For any type of implant system. n Without a complete surgical kit = a specific sequencer for the first drilling ø 2.2 mm.

teknika

lab

CAD-CAM PARTNER OF THE LABS

DESIGN (CAD) The computer-aided design of prosthetic components can be achieved using a conventional model, a wax-up or an STL file of any source.

MANUFACTURING (CAM)

COMPLETE PRODUCT OFFER

Prosthetic components are manufactured within 24 to 96 hours at our production centre in Sallanches (France), or in your laboratory if you have the right machines.

n Any work on natural tooth stumps, n    Any work on screw-retained or cemented implant abutments, n Customized, anatomical abutments, n High-precision machined bars, n Bridges.

167

VII. Services

teknikalab is a production centre offering a set of machined prosthetic solutions with computer-aided & custom-made design and manufacturing.


P R O D U C T S C A TA L O G U E 2 0 14

teknika

p -A

Fr

Manu ench factu ring

teknika

global s ol

gy - eu ro olo t n

ka gro kni u te

teknika

Implants that adhere to the strictest regulations in the field

s

i f e

L

A global solution FOR IMPLANTOLOGY

a

e

lab

m

teknika

i

teknika

P R O D U C T S C A T A L O G U E 2 0 14

for imp la ion ut

A GLOBAL SOLUTION F O R I M P L A NTO LOGY

t

i

euroteknika 726 rue du GĂŠnĂŠral De Gaulle - 74700 SALLANCHES - France

Tel.: +33 (0)4 50 91 49 20 - Fax: +33 (0)4 50 91 98 66 sales@euroteknika.com - www.euroteknika.com catalogue_GB_2014_0514

A global solution for implantology Imprimerie PLANCHER - Bonneville


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.