Catalog KAYSUN 2018

Page 1

MARCH 2018

CATALOGUE KAYSUN HVAC systems


www.kaysun.es www.frigicoll.es


Inspiration, Innovation, Evolution

The total or partial reproduction of this catalogue without the express authorisation of Frigicoll S.A. is prohibited.


GENERAL CONTENTS

GENERAL CONTENTS Climate control and energy tariff March 2018

RESIDENTIAL PRODUCT RANGE SUITE 1X1..............................................................................................................28 INTRODUCTION TO THE PRODUCT RANGE.............................................28 SETS...............................................................................................................32 PORTABLE..............................................................................................34 PRODIGY R-32.........................................................................................36 PRODIGY R-410A....................................................................................38 AUREA II R-32 ....................................................................................... 40 AUREA II R-410A ...................................................................................42 ONNIX .................................................................................................... 44 DOUBLE FLOW CONSOLE..................................................................... 46 MULTISYSTEM SUITE........................................................................................ 48 INTRODUCTION TO THE PRODUCT RANGE............................................ 48 R-410A MULTISYSTEM......................................................................... 50 R-32 MULTISYSTEM............................................................................... 51 R-410A OUTDOOR UNITS.......................................................................52 R-32 OUTDOOR UNITS ..........................................................................54 PRODIGY..................................................................................................56 AUREA II................................................................................................. 58 ONNIX .................................................................................................... 60 DOUBLE FLOW CONSOLE .....................................................................62 CASSETTE ............................................................................................. 64 DUCTS.....................................................................................................66 R-410A COMBINED ............................................................................... 68 R-32 COMBINED .....................................................................................78 KEY INSTALLATIONS..................................................................................82

AQUATIX DOMESTIC HOT WATER RANGE INTRODUCTION TO THE PRODUCT RANGE.................................................... 86 UNITS AQUANTIA....................................................SINGLE BLOC..........................94 AQUANTIA....................................................DUAL BLOC............................ 98 DOMESTIC HOT WATER DEPOSITS............BS, G...................................... 102 COMPAK........................................................KHP ACS................................ 106 KEY INSTALLATIONS.......................................................................................108

4

ZEN R-410A COMMERCIAL RANGE INTRODUCTION TO THE RANGE....................................................................114 SETS...................................................................................................................116 CASSETTE (600X600)................................................................................118 SUPERSLIM CASSETTE............................................................................ 120 FLOOR / CEILING....................................................................................... 124 DUCTS........................................................................................................ 128 FLOOR STANDING..................................................................................... 132 TWINS............................................................................................................... 134 KEY INSTALLATIONS..................................................................................... 136

ZEN R-32 COMMERCIAL RANGE INTRODUCTION TO THE RANGE...................................................................140 SETS.................................................................................................................. 142 SUPERSLIM CASSETTE.............................................................................144 FLOOR / CEILING....................................................................................... 146 DUCTS.........................................................................................................148

LARGE-CAPACITY ZEN COMMERCIAL RANGE INTRODUCTION TO THE RANGE................................................................... 152 HIGH-CAPACITY SETS OF DUCTS.................................................................. 153 AIR CONDENSED - FRONT DISCHARGE......154 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN3...........................156 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN4 S....................... 158 WATER-CONDENSED................................................................................160 STATIC PRESSURE GRAPHS..................................................................... 162 KEY INSTALLATIONS..................................................................................... 164

VENTILATION HEAT RECOVERY VENTILATORS RANGE HEAT RECOVERY VENTILATORS..................................................................168 ERP PRO.....................................................................................................170 AZURE........................................................................................................172 STATIC PRESSURE AND EFFICIENCY GRAPHS.......................................174


Inspiration, Innovation, Evolution

VRF INDUSTRIAL AMAZON RANGE INTRODUCTION TO THE RANGE...................................................................... 1 7 8 INDOOR UNITS...................................................................................................184 MURAL........................................................ ...........KAYF...........................188 DOUBLE FLOW CONSOLE......................................KSDF..............................190 FLOOR STANDING EXPOSED/CONCEALED...........KS(E)F...........................192 FLOOR / CEILING........................................ ............KPCF.............................. 194 1-WAY CASSETTE....................................... ............KCOF.............................. 196 ART FLUX 360ยบ (600x600) CASSETTE..................KCIF............................... 198 ART FLUX 360ยบ CASSETTE........................ ............KCIBF............................ 200 DUCTS.......................................................... ............KPDF............................. 202 STATIC PRESSURE GRAPHS.............. .................................................. 204 HIGH PRESSURE DUCTS........................... ............KPDHF.......................... 208 STATIC PRESSURE GRAPHS.............. .................................................. 210 KAHU........................................................... ............KAHU............................ 214 DOMESTIC HOT WATER UNIT...............................KWF............................... 216 OUTDOOR UNITS................................................................................................. 218 2 PIPES ................................................................................................................222 MINI AMAZON II SINGLE-PHASE.................................... .......................KMF DVN2......... 224 THREE-PHASE.............................................................KMF DTN2......... 226 AMAZON SINGLE FRONT AIR DISCHARGE......................KMF................... 228 AMAZON SINGLE VERTICAL AIR DISCHARGE DN3...........K2UF DN3......... 230 AMAZON SINGLE VERTICAL AIR DISCHARGE DN4 S......K2UF DN4 S...... 232 AMAZON IV PRO......................................... .......................K2F DN4S..........236 AMAZON III W............................................. .......................K2F DN3W........ 238 3 PIPES ................................................................................................................ 240 AMAZON III PRO......................................... .......................K3F DN3S.......... 242 INVERTER BOXES................................ .......................KVB.................... 244 SIZING ..................................................................................................................246 DISTANCES AND HEIGHT DIFFERENCES .........................................................256 KEY INSTALLATIONS .........................................................................................262

NEXUS CHILLERS RANGE INTRODUCTION TO THE RANGE..................................................................... 288 CHILLERS.............................................................................................................292 MINICHILLERS FULL DC INVERTER.................KEM D(V)(T)N...................294 MODULAR CHILLERS FULL DC INVERTER...........................................KEM DNS3........................296 MINICHILLERS FULL DC INVERTER WITH HYDRAULIC KIT.......................................KEM DNS3 KH.................298 FIXED SCROLL MODULAR CHILLERS..............KEM HN3......................... 300 EXTERNAL HYDRAULIC KITS...........................KH......................................302 ROTARY SCREW CHILLERS....................................................................... 304 CENTRIFUGAL CHILLERS............................................................................306 KEY INSTALLATIONS....................................................................................... 308

FAN COILS RANGE INTRODUCTION TO THE PRODUCT RANGE...................................................314 UNITS WALL ....................................................................KFC-AY..........................318 FLOOR / CEILING .................................................KFC-S(E)........................320 CASSETTES 600x600 ..........................................KFC-CI............................322 CASSETTES ..........................................................KFC-CIS.........................324 DUCTS ..................................................................KFC-PD..........................326 HIGH-PRESSURE DUCTS ....................................KFC-PDH........................328 KEY INSTALLATIONS.......................................................................................330

CONTROLS CONTROL SYSTEM RANGE INTRODUCTION TO THE PRODUCT RANGE.................................................... 268 OUR RANGE OF PRODUCTS....................................................................... 269 WIRELESS SINGLE CONTROLLERS AND WIRED CONTROLLERS.......... 270 CENTRALISED CONTROLLERS....................................................................272 INTEGRATED CONTROLLERS..................................................................... 274 ACCESSORIES.............................................................................................. 282 KEY INSTALLATIONS........................................................................................ 284

5


BUSINESS GROUP

Who we are Frigicoll is a family-owned Spanish company that has been in operation for more than 60 years, and is a pioneer in the introduction of technological solutions of leading global brands in various sectors of industry. At Frigicoll we undertake comprehensive projects, supplying machinery to the air conditioning, energy, transportation, food and catering and refrigeration sectors, as well as to the household appliances sector.

BUSINESS UNITS IN WHICH WE OPERATE

Transport Refrigeration

Refrigeration

Household appliances

HVAC systems

Hotels/Catering

Spare Parts / After Sales

This is our story: 1957

1969

1975

1985

1988

Fernando Coll Soms began his operations in the automobile sector as an importer and distributor of spare parts and accessories. In the 1960s, he added air conditioning systems and, later, refrigeration equipment for transport to his repertoire.

We opened our first office in Madrid. This period was characterised by a broad vision of the needs of the market and the subsequent diversification of products.

The name of the company was changed to Frigicoll, S.A.

Joint venture created with Thermo King.

A new branch is opened on the Canary Islands.

6

1967

1970

1982

1987

1990

Fernando Coll Soms, S.A. is founded. The company became a distributor of the Liebherr brand.

The company started production of refrigeration units for transport, becoming the only Spanish manufacturer engaged in this activity.

The company became a distributor of Thermo King in Spain.

The climate control business was created.

We established a presence in Portugal.


Inspiration, Innovation, Evolution

OUR VALUES

CSR

Our whole history has been notable for our contribution to the market: the best quality of product, trust, proximity and excellence in customer service and an ongoing quest for improvement and innovation, attributes that have made us leaders in the market. With a long record of providing premium integrated solutions, we face the future with the desire to keep searching for new, sustainable technological solutions.

Corporate social responsibility is one of the fundamental pillars of Frigicoll, carrying out actions based on the growth and social commitment of its employees and actions that help create a better, fairer and more sustainable world.

60 years

+450

+15

of history

employees

facilities spread out across Spain

1996

2002-2011

2012

We consolidated our position, opening two new subsidiaries in Murcia and Valencia.

We started up subsidiaries of the Frigicoll Group in Seville, Lugo, Southern Madrid, Cadiz and Northern Barcelona in the area of refrigeration systems for transport, as well as the Ecliman company, a manufacturer of refrigeration systems designed to improve energy efficiency and environmental protection.

We boosted the central zone with the refurbishment and development of the installations in Madrid (Coslada) and inaugurated the logistics centre in VilaRodona.

2OO million in turnover

2017 We inaugurated our New headquarters in Barcelona, as well as “The Art of Living Frigicoll� in Madrid, a space to display our high-end household appliances .

We reached an agreement with the Midea household appliance brand for the exclusive distribution of their air conditioning units in Spain.

2001

2004

2015

Relocation of our headquarters from Madrid to the municipality of Coslada. In this way, we expanded our presence and positioned ourselves as pioneers and leaders in the Spanish market for high-tech products and first-rate solutions.

We created Kaysun, our brand specialised in both the industrial segment and residential segment with a very clear idea: to transfer all of the experience in products and services at the company to the development of this line of business.

We completed the construction of our Headquarters in the south of Madrid (Getafe) in order to, together with Coslada offices, facilitate access to our customer service bases located in the downtown area.

7


BUSINESS GROUP

Business units

Inventor of the refrigeration system for transport.

Transport Frigicoll offers refrigeration systems for the transportation and distribution of perishable products, climate control for coaches and buses, refrigerated mobile containers and solutions for the transportation of pharmaceutical products. It holds the official concession for the ThermoKing brand in Spain and Portugal and offers technical support through a network of its own workshops and associated services that covers the whole of Spain, with ongoing service available 24 hours a day, 365 days a year.

A pioneer in refrigerated mobile containers.

More than 60 years as leader in the world of cold.

Household appliances Frigicoll offers all equipment for high-end household cooking through the Liebherr, De Dietrich and Falmec brands, leaders in refrigeration, cooking and vacuuming. The three brands are a perfect alliance of design, quality and technology, turning each kitchen into a unique space and guaranteeing the best services for the client.

The best, most powerful induction and the ability to detect recipients.

The most silent extractor hoods in the market (NRS technology).

The first oven with a cloud WiFi connection (Lainox Naboo).

An internal energy cycle that reduces detergent, water and electricity consumption by 50%

Strict temperature and moisture control in laboratory coolers and reliability in gastronomy.

Hotels/Catering Frigicoll offers a wide range of functional equipment with state-of-the-art technology that facilitates the work of professional kitchens. What sets us apart on large premises is the ability to create integrated projects.

Efficiency and high performance in large-scale kitchens and collectives.

The world’s first and only school that specifically provides gourmet pizza training (Pizza University). Plus the following brands:

8


Inspiration, Innovation, Evolution

Cooling units with lower refrigerant charge, if compared to conventional systems, and with improvements in the energy efficiency of the system.

Refrigeration Frigicoll offers complete commercial and industrial refrigeration solutions through own brands such as Frigicoll and Ecliman and through other very prestigious brands such as Dorin and Arneg. Sustainable, highly energy-efficient, robust and reliable solutions.

A complete range of commercial and industrial evaporators.

The mobile cooling unit and compressor that best reflect the trend towards new refrigerants.

We manufacture one in five AC devices worldwide.

Great versatility of equipment and advanced technological innovation.

HVAC systems Frigicoll has an alliance with Midea, a world leader in air treatment equipment, to offer integrated climate control projects suitable for all types of installations, from the residential range to the industrial range. Frigicoll is also present in leading projects worldwide with its own brand, Kaysun, with which it has experienced rapid expansion overseas.

Spare Parts

After-sales service

Frigicoll also has a spare parts business, the aim of which is to provide the best possible service with delivery within 24h and specialist advice and service for each product over the phone, so as to protect the prestige and excellence of the products represented.

To ensure the quality of service at all stages of its value chain, Frigicoll has a highly specialised after-sales service area to foster the agile and effective resolution of any incidents that may arise.

Frigicoll original spare parts • 2,500m2Automated logistics warehouse. • 30,000 parts in stock. • + 200 shipments daily. • + 400,000 parts delivered every year.

Frigicoll after-sales service • ISO 9001 and ISO 14001 • +170 technical assistance points acrossthe whole of the mainland, the Canary Islands and Portugal, as well as 11 service centres. • Uninterrupted service all year round (24/7 in the transport unit).

9


OUR ORIGINS

“A well-established Team” Over more than 60 years, Frigicoll has worked at all times in collaboration with the most reputable brands in the different business units that comprise the company. Our technical team has combined, for each and every project, the premium qualities of our equipment with its professional experience to achieve the best outcomes. Today we complete key installations, noteworthy due to both the technological prowess of their solutions and their social importance. In the HVAC Business Unit, we are proud to apply our first-hand knowledge,acquiredfromourlonghistoryandthebestprofessionals, to the continual development of our own brand, Kaysun, which

grows more established every day with a strong national and international plan. We have a clear goal: to continue providing the best residential and industrial solutions with comprehensive offerings underpinned by a constantly evolving and diverse range of products. That is why we remain loyal to our brand's philosophy – a balance between technology, efficiency, cost and warranty. We believe that the best way to explain to you why Kaysun is rising to the top in the sector is to invite you to experience our work first hand. Thank you for joining us.

Europe France England Ireland Italy Portugal Spain Andorra Belgium The Netherlands Luxembourg Slovenia Malta Romania

The Americas Martinique Guadeloupe French Guiana

Africa Morocco Reunion

10


Inspiration, Innovation, Evolution

“Ten reasons why we stand out�

1

2

THE FRIGICOLL GUARANTEE

Frigicoll is known for its premium products and its broad experience in excellent after-sales services. KAYSUN, the company's own brand, was developed with the standards for quality and technological innovation that have always set us apart.

MAXIMUM RELIABILITY OF OUR EQUIPMENT

6

CUTTING-EDGE TECHNOLOGY

Our forward-looking approach goes hand-in-hand with the incorporation of the latest technology in all of our equipment. We include features that improve everything from energy consumption to practicality and comfort, as in the case of the built-in motorised panel used in cassettes models.

7

SMART CONTROL

We guarantee that our units will have a long service life, thanks to top-quality materials. This ensure that the need to make use of their warranties is reduced to a minimum.

Our smart control devices, allow us to offer comfort and well-being in any facility. The K01-WIFI device is the first smart solution for our units, providing the option of programming and managing air conditioning units inside and outside your home.

ISO

3

ISO 9001 / ISO 14001

The quality of our products and environment benefits are two key pillars for KAYSUN. We are proud to have achieved ISO 9001 and ISO 14001, under the seal of Frigicoll.

4

WIDE RANGE

We offer comprehensive solutions for any facility thanks to the diversity of our product ranges. From residential split systems to the most complex water terminal units, and including air curtains, recovery systems, VRFs, chillers, solar and domestic hot water units.

5

COMPREHENSIVE PROJECTS

Our team of expert technicians carries out HVCA and ventilation comprehensive specific projects for every single customer, which allows our company to be able to adapt to any space and need. A personalised advice complements this service, thus ensuring the correct performance of our installation works.

8

COMMITTED TO THE ENVIRONMENT

Our equipment is manufactured almost entirely from recyclable materials. We have reduced consumption as far as possible in STANDBY mode and have improved the energy efficiency of units working at full capacity, resulting in energy savings for facilities.

9

EXCELLENT AFTER-SALES SERVICE

We work to solve all incidents as quickly as possible, leaving our customers completely satisfied with our after-sales service. We have a team of expert professionals working for you.

10

THE BEST MANAGEMENT OF SPARE PARTS IN THE SECTOR

We understand the key role of air-conditioning systems play in our facilities, and we offer unbeatable replacement services. Our commitment is absolute and we offer immediate solutions.

11


EUROPEAN DIRECTIVE ERP

EUROPEAN DIRECTIVE ErP Kaysun remains committed to inspiration, innovation and evolution. That is why it is proud to present a 2018 catalogue in which all products meet the requirements of the new energy regulations in force.

Icons for the 2018 catalogue. Green colour, which stands for ecological innovation, is hard to miss in our 2018 catalogue, showing the energy efficiency of each of our products. ErP

SCOP

SEER

ErP

ECODESIGN DIRECTIVE On January 1st, 2013 the "ecodesign" directive took effect, which in order to reduce energy consumption and benefit the environment, requires the adoption of legal measures to establish requirements for energy labelling and supplying energy-related information about products. The Commission adopted Regulation 626/2011, introducing the new energy labels which are mandatory for air conditioning units connected to the grid with a nominal refrigerating power (or nominal heating power, if the unit only runs as a heat pump) of less than 12kW.

These labels contain seasonal energy performance levels, which are based on different outdoor temperatures and part-load efficiencies to calculate a level of annual consumption in extremely close detail, thus demonstrating in the most apparent manner possible the advantages of the Inverter technology used by Kaysun. The sound level rating of the unit is also displayed. It is important to make the distinction between SEER and SCOP, where “S” stands for “Seasonal” to indicate the seasonal variation of annual energy consumption, which is usually measured according to the hours a unit runs in different climatic zones over a year.

ENERGY EFFICIENCY CLASSES for air conditioners CLASSES*

SEER

SCOP

A+ + +

SEER ≥ 8,50

SCOP ≥ 5,10

A+ +

6.10 ≤ SEER < 8.50

4.60 ≤ SCOP < 5.10

A+

5.60 ≤ SEER < 6.10

4.00 ≤ SCOP < 4.60

A

5.10 ≤ SEER < 5.60

3.40 ≤ SCOP < 4.00

B

4.60 ≤ SEER < 5.10

3.10 ≤ SCOP < 3.40

C

4.10 ≤ SEER < 4.60

2.80 ≤ SCOP < 3.10

D

3.60 ≤ SEER < 4.10

2.50 ≤ SCOP < 2.80

(*) with the exception of dual and single duct units.

Minimum energy efficiency values have been established for both cooling and heating mode for all products for sale after January 2013 to which that regulation applies. Inefficient products will

12

not be able to be sold on the European market, since they do not meet the requirements of the mentioned regulation.


Inspiration, Innovation, Evolution

We would like to note that there are also restrictions regarding sound levels, and therefore Kaysun offers efficient and environmentally friendly products that provide comfort and a quality lifestyle to end users.

MINIMUM ENERGY EFFICIENCY REQUIREMENTS ACOUSTIC POWER IN dB(A)

NOMINAL POWER

≤ 6kW

≤ 12kW

Indoor

60

Outdoor

65

Indoor

65

Outdoor

70

MINIMUM ENERGY EFFICIENCY REQUIREMENTS 2015 NOMINAL POWER

GWP OF THE REFRIGERANT

AIR CONDITIONERS SEER

DUAL DUCT

SCOP

EER

SINGLE DUCT COP

EER

COP

If the GWP > 150

4.60

3.80

2.60

2.60

2.60

2.04

If the GWP < 150

4.14

3.42

2.34

2.34

2.34

1.84

If the GWP > 150

4.30

3.80

2.60

2.60

2.60

2.04

If the GWP < 150

3.87

3.42

2.34

2.34

2.34

1.84

< 6KW

6 - 12 KW

ENERGY LABELS The label makes a distinction between climatic areas, and therefore offers users more detailed information and a more accurate idea of the efficiency of the units according to the climatic area in which they are located. In addition to the Ecodesign directive, there is another directive hat affects Kaysun. All units with fans with a motor that consumes between 125W and 500 kW of energy meet certain minimum energy efficiency requirements.

CLIMATIC ZONES The map below shows the three climatic zones that have been established for a better evaluation: Average (*) Annual temperature of Strasbourg. Hot Annual temperature of Athens. Cold Annual temperature of Helsinki.

SEER and SCOP. These values indicate the Seasonal Energy Efficiency Ratio for refrigerating (SEER) and heating (SCOP) calculated based on annual hours of use in different climatic zones. ENERGY CLASS For heating and cooling, labels will increase up to Class A+++. SOUND LEVELS The sound level of indoor and outdoor units, expressed in decibels.

(*) It is only mandatory to express the SCOP for the average climate zone.

13


OUR RANGES

SUITE RESIDENTIAL PRODUCT RANGE 2.0 R-410A

PORTABLE

2.8

3.5

4.2

4.8

5.2

6.2

7.1

7.8

8.0

10.5

NEW

12.0

14.0

16.0

kW pag. 34

R-32 NEW

R-410A

SUITE 1x1

2.6

PRODIGY

36-38

AUREA II

40-42

R-410A

R-410A

ONNIX

44

R-410A

CONSOLE

46

R-32 NEW

R-410A

PRODIGY

56

AUREA II

58

R-410A

R-410A

60

ONNIX

R-32 NEW

R-410A

62

CONSOLE

MULTI TYPE

R-410A

R-32 NEW

64

CASSETTE

NEW

R-410A

66

DUCTS

2x

2x

R-410A

3x

3x

52

OUTDOOR 4x 5x 2x 3x

54

OUTDOOR 4x 5x

14


Inspiration, Innovation, Evolution

AQUATIX

DOMESTIC HOT WATER RANGE

AQUANTIA SINGLE BLOC

4

5

HEAT PUMP

8

12

14

16

kW pag.

94

THREE-PHASE

94

5

6

7

8

12

14

16

kW pag.

SINGLE-PHASE

98

THREE-PHASE

98

130

180

230

280

330

L

COMPAK

TANKS FOR DOMESTIC HOT WATER

pag.

106

160

DEPOSITS

7

SINGLE-PHASE

4

AQUANTIA DUAL BLOC

6

190

270

475

750

1000

1250

1500

1750

2000

2225

2500

L

pag.

102

15


OUR RANGES

ZEN

COMMERCIAL RANGE 2.6

R-410A

600x600 CASSETTE

SUPERSLIM CASSETTE

1X1 SYSTEMS

FLOORCEILING

7.1

9.0

10.5

12.5

14.0

16.0

20.0

25.0

28.0 40.0 45.0

56.0

kW

pag.

121 122

.

OUTDOOR AXIAL OUTDOOR CENTRIFUGE

R-410A

.

OUTDOOR AXIAL OUTDOOR CENTRIFUGE

R-410A

5.2

118 OUTDOOR CENTRIFUGE

R-410A

3.5

125 126

.

129

DUCTS NEW

OUTDOOR CENTRIFUGE

R-410A

R-410A

FLOOR STANDING WHILE STOCKS LAST

R-410A

OUTDOOR AXIAL

600x600 CASSETTE

OUTDOOR AXIAL

130

.

133 133 135 135

R-410A

SUPERSLIM CASSETTE

TWINS

135 R-410A

135

FLOOR-CEILING

135 R-410A

135 DUCTS NEW

16

135


Inspiration, Innovation, Evolution

ZEN

COMMERCIAL RANGE 2.6

3.5

5.2

7.1

9.0

10.5

12.5

14.0

16.0

20.0

25.0

28.0 40.0 45.0

56.0

kW

SUPERSLIM CASSETTE

pag. 144

1X1 SYSTEMS

R-32

R-32 NEW

FLOORCEILING

146

R-32 NEW

DUCTS

148

NEW

AIR CONDENSED

FRONT AIR DISCHARGE

VERTICAL AIR DISCHARGE DN3

154 156

R-410A

VERTICAL AIR DISCHARGE DN4

WHILE STOCKS LAST

158

R-410A

WATER CONDENSED

HIGH CAPACITY

R-410A

NEW

160

R-410A

VENTILATION

HEAT RECOVERY

500

700

AIR CURTAINS AND HEAT RECOVERIES PRODUCT RANGE 800

900

1000 1200 1400 1800 2000 2300 2400 2600 2800 3000 3200 m3/h

TYPE

pag.

ERP PRO

VENTILATORS 170

AZURE

VENTILATORS 172

17


OUR RANGES

AMAZON

INDUSTRIAL VRF RANGE 1.5

HIGH WALL DOUBLE FLOW CONSOLE FLOOR STANDING EXPOSED/ CONCEALED

FLOOR / CEILING

INDOOR UNITS

CASSETTE 1 WAY CASSETTE 600X600 CASSETTE 840X840 Ducts HIGH PRESSURE DUCTS DOMESTIC HOT WATER KAHU MINI AMAZON II SINGLE-PHASE MINI AMAZON II THREE-PHASE

2 PIPES

OUTDOOR UNITS

AMAZON UNITARIO FRONT AIR DISCHARGE AMAZON UNITARIO VERTICAL AIR DISCHARGE DN3 AMAZON UNITARIO VERTICAL AIR DISCHARGE DN4 AMAZON IV PRO

3 PIPES

AMAZON III W

18

AMAZON III PRO

2.2

2.8

3.6

4.5

5.6

7.1

8.0

9.0

10.0

11.2

12.0

14.0


Inspiration, Innovation, Evolution

16.0

18.0

20.0

22.4

25.0

25.2

26.0

28.0

33.5

40.0

45.0

50.0

56.0

61.5

67.0

73.0

75.0

90.0

kW

Pag. 188 190 192 194 196 198 200 202 208 216 214 224 226 228 230 232 236 238

242

19


OUR RANGES

CONTROLS

CONTROL SYSTEM RANGE SUITE

WIRELESS

PRODIGY 1x1

AUREA II 1x1

ZEN

ONNIX 1x1

MULTI

CONSOLE 1x1

Pag.

KID-02 S

270

KI-02.3 S

270

KC-01 S

INDIVIDUAL WIRED

AMAZON

Except for Aurea II

SuperSlim Cassette and Floor Standing models

270

only Ducts

SuperSlim Cassette and Floor Standing models

271

only Ducts

Except for SuperSlim Cassette and Floor Standing models

271

Except for Aurea II model

Except for SuperSlim Cassette and Floor Standing models

271

Except for Aurea II model

Except for SuperSlim Cassette and Floor Standing models

271

KC-03 SPS KC-03.1 SPS NEW

KC-02.1 H

KCT-02.1 SR

272

CENTRALISED CONTROLS

KMC-32 E

KCCT-64 I (B) KCCT-64 IPS NEW

KCCT-384 IPS NEW

KCC-64 WEB

Except for wallmounted and KSD models

272

Except for wallmounted and KSD models

272

Except for wallmounted and KSD models

273

Except for wallmounted and KSD models

273

NEXUS CHILLERS PRODUCT RANGE 5

7

10

12

14

16

26

30

35

52

65

71

95

130

160

195

200

225

250

Single-phase MINICHILLERS INVERTER

CHILLERS

Tri-phase

MODULAR FULL DC INVERTER CHILLERS MODULAR CHILLERS

ROTARY SCREW CHILLERS

4x

Without hydraulic kit With hydraulic kit

4x

Fixed Scroll

20

4x

4x

Air-water

Water-water

2 CHILLERS CENTRIFUGAL

4x

3

4

Check your model

5

260

315

340


Inspiration, Innovation, Evolution

SUITE

AMAZON

MULTI

pag.

K01-LON

except for wallmounted and KSD models

274

K01-BACNET

Except for wallmounted and KSD models

276

Except for wallmounted and KSD models

275

Except for wallmounted and KSD models

275

Except for wallmounted and KSD models

280

Except for wallmounted and KSD models

277

PRODIGY 1x1

INTEGRATED CONTROLS

ZEN

AUREA II 1x1

ONNIX 1x1

CONSOLE 1x1

K02MODBUS

K01MODBUS

KAYNET CONTROL

K01-KNX

278

ACCESSORIES

K01 WIFI

K01-WATT

283

Except for MiniAmazon II models

282

KAHU

380 400 435 440 500

510

520 540 565 600 620 630 640 685 690 720

740

750

760 805

815

900 1000 1100 1200 1385 1620 1780

kW pag. 294 294 296 298 300

6

Check your model

304

Check your model

305

7

Check your model

8

9

10

MW 306

21


OUR RANGES

FANCOILS

WATER TERMINAL UNITS PRODUCT RANGE 370

490

540

INDOOR UNITS

HIGH WALL 2 DUCTS

FLOOR / CEILING 2 PIPES

600

680

750

780

980

1500

m3/h pag.

318

EXPOSED

320

CONCEALED

320

2 DUCTS

322

4 DUCTS

322

CASSETTE 600 X 600

340

510

600

680

730

1020 1175 1230 1360 1450 1530 1580 1700 1870 2380 3060 3740 m3/h pag.

2 DUCTS

324

4 DUCTS

324

2 DUCTS

326

4 DUCTS

326

2 DUCTS

328

INDOOR UNITS

CASSETTE

Ducts

HIGH PRESSURE DUCTS

22


REFRIGERANT

R-134A

R-32

ICONS

R-134A REFRIGERANT The units works with R-134A ecological refrigerant.

DESCRIPTION

R-32 REFRIGERANT The unit works with R-32 ecological refrigerant.

MULTIPLE AIR INLETS This unit is fitted with four air return inlets: upper inlet, lower inlet, right inlet and left inlet.

R-410A REFRIGERANT The units works with R-410A ecological refrigerant.

FRESH AIR SUPPLY “X %” of fresh air directly enters the indoor unit through an orifice.

MODULAR Can be combined with other units up to power "x", by connecting the inlet and outlet pipes between units. SUPER SLIM The new Super Slim cassette can be fitted into any space. ErP Unit that complies with the European Parliament and Council of the European Union's Directive which establishes the ecological design requirements applicable to products that use energy.

AUTOMATIC ADJUSTMENT OF THE BLADES The unit has the capacity to automatically position the blades at the same angle that they were at when it was shut off the last time.

4.0

SCOP 4.0 The heat pump performance of a set of units exceeds SCOP 4.0.

AIR OUTLET 360º The indoor unit is capable of spreading a 360º air flow, thus providing high comfort and reaching all corners of the room.

A

SEER Classification of energy efficiency according to seasonal performance for cooling.

8ºC HEATING This feature keeps the temperature in the room from dropping below 8ºC by turning on the unit automatically in heat mode until it reaches 17ºC.

DRAINAGE PUMP A system which is capable of removing condensate up to 750 mm.

SELF-CLEANING A feature of the indoor unit which automatically cleans the machine's battery so as to continue providing fresh, purified air every day.

TWO COMMUNICATION WIRES The system uses two shielded communication wires without polarity.

LOW SOUND LEVEL New technological advances have allowed the level of sound produced by the indoor units to be reduced by up to 20 dB.

SCOP

++

x2

AIR OUTLET The unit has two air outlets: upper and lower.

ADDRESSING The control system allows setting an address for indoor units inside the communication bus. 50/60 Hz

TWINS

ACS

DC

INVERTER

HERTZ The units can function at 50 or 60 Hz. MOTORIZED PANEL This type of panel descends automatically by up to 4 metres to facilitate the maintenance and cleaning of the filter.

EYE DETECTOR A function that automatically turns off the unit when the sensor does not detect movement in the room for 30 minutes. The unit will switch on again when someone enters the room.

SOLAR PANEL A very efficient set of equipment which exploits the sun's energy using a solar panel.

FOLLOW ME A feature which changes the operating mode based on the remote controlled temperature sensor with the aim of maintaining maximum comfort.

TWINS Connection system that allows the two indoor units to be combined with an outdoor unit, making installation easier and more economical.

INTELLIGENT This feature allows changing the operation parameters of the unit and extracting operation data.

DOMESTIC HOT WATER A system that produces domestic hot water and underfloor heating. DC INVERTER COMPRESSOR This feature allows to regulate the power of the compressor, providing optimum control and extremely efficient operation.

LED DISPLAY The indoor unit displays the information on a digital display panel.

ECO MODE A control feature which reduces consumption, offering high energy efficiency thanks to automatic temperature regulation. NIGHT MODE A feature of the indoor unit which reduces the sound level during the night for a more comfortable sleep.

-

TURBO

COOLING AND HEATING Our units are equipped with air conditioning and a heat pump.

SILENCE MODE A function of the indoor unit that reduces sound pressure using the lowest speed of the fans.

1W

3D TECHNOLOGY Triple DC inverter technology that allows a more constant temperature, high energy saving and significant energy efficiency. DC

INVERTER

DC

INVERTER

INDOOR

DC INVERTER EXTEERNAL FAN The unit is fitted with a DC Inverter external fan. DC INVERTER INTERNAL FAN The unit is fitted with a DC Inverter internal fan.

TURBO MODE This feature reaches the selected temperature within a very short time.

WEEKLY PROGRAMMER A control feature which schedules when the unit will turn on/shut off according to the day and time during the week.

ROTARY Unit fitted with a rotary heat exchanger to provide a higher air flow. SCROLL The unit is fitted with a highly efficient and powerful scroll compressor.

+

MUTE This feature allows permanently cancelling the indoor unit alarm beeper.

HYDRAULIC KIT A complete, built-in hydraulic kit. KIT

OUTDOOR

AUTOMATIC MODE The indoor unit automatically changes to heating or cooling operating mode based on the temperature selected.

AUTO

CONDENSATION CONTROL Allows the system to refrigerate, even with low outdoor temperatures. SIMULTANEOUS COOLING/HEATING Heat recovery technology which allows cold and heat to be obtained simultaneously within the same system, optimising the user's comfort.

SCROLL

SWITCH OFF DISPLAY This feature allows switching off the display of the indoor units, if necessary.

24ºC 24ºC

SCREW COMPRESSOR Unit fitted with a screw compressor suitable for high compression ratio.

!

REFRIGERANT CONTROL A sensor on the outdoor unit and an alarm on the indoor unit's display alert the user of the detection of a possible refrigerant leak.

!

COMFORT COMFORT

ENERGY

AIR INTAKE The indoor unit has two possible air intakes: the upper and the rear intake.

SCOP Classification of energy efficiency according to seasonal performance for heating.

SCOP

SEER

INSTALLATION AND SERVICE

A B

A

++

TECHNOLOGY

AUTO SWING The wide angle of rotation of the horizontal and vertical blades guides the cold or hot air, creating a flow capable of reaching any corner of the space.

AIR DISTRIBUTION

DESIGN

COMPACT Advances in design have reduced the size of the indoor and outdoor units without overlooking any technological details.

STAND BY The "standby mode" feature allows 80% energy saving with only 1W consumption by the LED display. TOUCH SENSITIVE KEYS The keys of the remote control are touch sensitive.

+ -

COMPENSATION TEMPERATURE The possibility of compensating for the difference in temperature between the indoor unit's sensor and the real temperature of the room in heating mode. Wi-Fi This unit can be controlled by a Wi-Fi network through a smartphone application.

23



CATALOGUE

KAYSUN HVAC systems


SUITE RESIDENTIAL PRODUCT RANGE SUITE 1X1...............................................................................................28 INTRODUCTION TO THE PRODUCT RANGE.........................28 SETS..........................................................................................32 PORTABLE..........................................................................34 PRODIGY R-32.....................................................................36 PRODIGY R-410A................................................................38 AUREA II R-32 ....................................................................40 AUREA II R-410A ...............................................................42 ONNIX .................................................................................44 DOUBLE FLOW CONSOLE..................................................46

MULTISYSTEM SUITE..........................................................................48 INTRODUCTION TO THE PRODUCT RANGE.........................48 R-410A MULTISYSTEM.............................................................50 R-32 MULTISYSTEM.................................................................51 R-410A OUTDOOR UNITS.........................................................52 R-32 OUTDOOR UNITS .............................................................54 PRODIGY....................................................................................56 AUREA II....................................................................................58 ONNIX .......................................................................................60 DOUBLE FLOW CONSOLE ........................................................62 CASSETTE .................................................................................64 DUCTS........................................................................................66 R-410A COMBINED ...................................................................68 R-32 COMBINED .......................................................................78 KEY INSTALLATIONS.............................................................82


SUITE RESIDENTIAL

SUITE

RESIDENTIAL PRODUCT RANGE

27


RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

SUITE 1x1 RESIDENTIAL PRODUCT RANGE

“ELEGANCE

Introducing our 1x1 residential units range. KAYSUN endeavours to offer the most complete range suitable for any type of aesthetic and requirement. Contributing to the maximum well-being of the user, at the vanguard of innovation and with a proposal that meets all of the requirements of the market and contains developments that constitute pioneering advances in the sector. The residential range units comply with the ERP (energyrelated products) directive of the EU, offering SCOP values of A, A+ and A++. The brand wishes to consolidate its position in the market by offering products with a seasonal energy efficiency

PRODIGY

AND COMFORT FOR YOUR HOME” under heat mode that are even higher than 4 in SCOP for some of its models. Therefore, we not only observe the current directives on energy efficiency, but future directives as well.

R-32 NEW

In its search for the best combination of efficiency and comfort, KAYSUN brings professional technological development to the end-user. The PRODIGY unit has been created to become the new emblem of domestic split equipment, and is positioned in the market as an unbeatable commitment to our fundamental values.

R-410A 28

+

EFFICIENCY

+

INTERACTIVITY

+

INSTALLATION

+

MAINTENANCE


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

INSTALLING • Installation template included and integral, strong and simple support. When installing the unit, leave a 50mm side shift margin.

• Fasteners system for supporting working on electrical connections.

front

panel

while

• The electric connection board is wide and strong.

• The unit's support is fitted with a hinge system, which provides 168 mm opening to allow for cooling and discharge connection.

INFORMATION SERVICING

+

EASY AND COMFORTABLE ACCESS TO THE FILTER WITHOUT DISASSEMBLING THE UNIT

+

SIMPLE AND QUICK OPENING THANKS TO ITS ROTATING FRONT PANEL.

+

FAN MAINTENANCE WITHOUT TAKING THE UNIT OFF THE WALL.

+

EASY ACCESS TO ELECTRONIC BOARD AND TO THE COMPLETE ELECTRICAL PANEL TO PERFORM CHECKING OR REPLACEMENT OPERATIONS.

+

EASY ACCESS TO EVAPORATOR IN CASE THAT CLEANING OR REPLACEMENT TASKS ARE REQUIRED.

29


RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

AUREA II With its elegant design, the main characteristic of this unit is that it works with both R-32 and R-410A refrigerant and incorporates all KAYSUN technology, with the most advanced functions in the range as a result.

+ +

PARAMETERS AND CONFIGURATION BY REMOTE CONTROLLER

LEAKAGE DETECTION SYSTEMS

+ +

SCOP OVER 4.0

WIFI CONTROL (OPTIONAL)

R-410A

OUTDOOR UNITS We wish to point out the whole range of outdoor units in the Kaysun SUITE RANGE. These units provides us with low noise levels, good performance and significant energy savings. A machine designed to make maintenance tasks easier and protect its main components in order to extend the useful life of the product.

+ +

R-410A

+

GREATER OUTPUT

ENERGY SAVING

SOUND LEVELS REDUCTION

• Strong structure.

• Compact finishing.

30


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

APP/WIFI KAYSUN has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.

+

WEEKLY TIMER

+

CHECK

+

BASIC FUNCTIONS

K03 WIFI USB ACCESSORY

DOWNLOAD OUR APPLICATION FROM:

www.kaysun.es

+

PLUG & PLAY

R-32 REFRIGERANT UNITS Frigicoll, by means of its KAYSUN brand have already started marketing some of its products fitted with R-32 refrigerant. The new EU regulations encourages the use of alternative gases, such as R-32 refrigerant gas. The R-32 has a 675 global warming potential (GWP), a very low rate if compared to the 2,088 GWP produced by R-410A refrigerant. It is more cost-efficient, 10 % more suitable and reduces charge volume by 25% because it is more compact. In addition, it offers better performance at an extreme outdoor temperature and is easy to reuse and recycle, as it is made up of a single refrigerant component.

PRODIGY

AUREA II

31


RESIDENTIAL PRODUCT RANGE POWER RANGE

SETS AND PORTABLE UNITS SUITE 1x1

32 32


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

2.6

5.2

7.1

KAY-35 DR8

KAY-52 DR8

KAY-71 DR8

KAY-35 DN8

KAY-52 DN8

KAY-71 DN8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

KAY-S 26 DN8

KAY-S 35 DN8

KAY-S 52 DN8

KAY-S 71 DN8

KAY-D 26 DN7

KAY-D 35 DN7

POWER kW

3.5

NEW

PORTABLE (Page 34)

KP-35 HN8

R-410A PRODIGY R-32

(Page 36) KAY-26 DR8

PRODIGY R-410A

R-410A

(Page 38)

KAY-26 DN8

AUREA II R-32

(Page 40) KAY-S 26 DR8

AUREA II R-410A

R-410A ONNIX

NEW

(Page 42)

(Page 44) KAY-D 52 DN7

R-410A DOUBLE FLOW CONSOLE

(Page 46) KSD-35 DVN11

R-410A

DISTANCES AND HEIGHT DIFFERENCES 26

35

52

71

TOTAL LENGTH

25

25

30

50

MAXIMUM HEIGHT

10

10

20

25

Note: The SUITE 1x1 range is currently in the process of obtaining the EUROVENT Certification.

33 33


RESIDENTIAL PRODUCT RANGE PORTABLE

PORTABLE

NEW

TECHNICAL SPECIFICATIONS MODEL

KP-35 HN8

Cooling capacity

kW

Cooling capacity

Kcal/h

3010

W

1350

Cooling input EER

2.6

Cooling energy class Air flow Sound pressure

A 3

m /h

386

dB (A)

65

Refrigerant Width/Height/Depth Net weight Power supply

34 34

3.5

R-410A mm

466/765/397

Kg

30

V / F / Hz

220-240/1/50


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

1W

R-410A

GENERAL CHARACTERISTICS

This year 2018 we introduce a new product: KAYSUN portable. A Cooling Mode Only unit fitted with R-410A refrigerant, it is easy to transport and place in any room of the house and includes a condensate auto-evaporation system. • The unit has 4 wheels to move it around the house and place it anywhere at our convenience. • Condensate auto-evaporation system.

• Auto-restart function. • Self-protection and self-diagnosis functions. • Timer On/Off function.

• Wireless controller included. • Control panel at the top of the unit.

KID-01 S STANDARD

+ +

EASY TO TRANSPORT

WIRELESS CONTROLLER INCLUDED

35 35


RESIDENTIAL PRODUCT RANGE CASSETTE

PRODIGY R-32

NEW

TECHNICAL SPECIFICATIONS SET

KAY-26 DR8

Cooling capacity (min./rated/max.)

kW

Cooling capacity (min./rated/max.)

Kcal/h

KAY-52 DR8

KAY-71 DR8

1.41/3.52/4.57

1.96/5.28/6.21

3.05/7.33/8.44

1213/3027/3930

1686/4541/5341

2623/6304/7258

100/700/1320

110/1250/1740

150/1500/2220

230/2260/3010

SEER

6.8

6.3

6.7

6.4

Cooling energy class

A++

A++

A++

A++

Cold input capacity (min./rated/max.)

W

1.20/2.64/3.43

KAY-35 DR8

1032/2270/2950

Cooling capacity (min./rated/max.)

kW

0.82/2.93/3.87

0.88/4.10/5.13

1.29/5.57/6.98

2.08/7.62/9.44

Cooling capacity (min./rated/max.)

Kcal/h

705/2520/3328

757/3526/4412

1109/4790/6003

1789/6553/8118

W

140/780/1380

150/1170/1830

220/1390/2330

330/2110/3150

SCOP

4.0

4.0

4.0

4.0

Heating efficiency class

A+

A+

A+

A+

SCOP (warm areas)

5.1

5.2

5.1

5.1

A+++

A+++

A+++

A+++

2.15

2.32

3.92

4.99

2.91

2.81

2.80

2.50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Heat input capacity (min./rated/max.)

Heating energy class (warm areas) Heating capacity -7ºC

kW

COP -7ºC Power supply

V / F / Hz

INDOOR UNIT

KAY-26 DR8

KAY-35 DR8

KAY-52 DR8

KAY-71 DR8

Air flow

3

m /h

486/433/329

550/490/360

810/720/550

1050/970/650

Sound pressure (Silence)

dB (A)

21

23

24

27

Width x Height x Depth

mm

717/302/193

805/302/193

964/325/222

1106/342/232

Net weight

Kg

7.5

8.2

10.8

14.3

Power wiring

mm2

From outdoor

From outdoor

From outdoor

From outdoor

Communication wiring

mm2

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

OUTDOOR UNIT

KAE-26 DR8

KAE-35 DR8

KAE-52 DR7

KAE-71 DR7

Compressor type

Rotary

Rotary

Rotary

Rotary

Outdoor airflow

m3/h

2000

2000

2100

2700

Sound pressure

dB (A)

55

55

57

59

R-32

R-32

R-32

R-32

700/12

800/12

1250/12

1600/24

Refrigerant Refrigerant charge / Supplementary charge **

gr

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9(5/8")

Piping max. length

m

25

25

30

50

Pipe height difference

m

10

10

20

25

Width/Height/Depth

mm

770/555/300

770/555/300

800/554/333

845/702/363

Net weight

Kg

26.4

26.5

37

48

Power wiring

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Communication wiring

mm2

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)

36 36


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

4.0 R-32

50/60

SCOP

24ºC

!

!

Hz

1W

24ºC

GENERAL CHARACTERISTICS

PRODIGY is the new KAYSUN wall unit. It represents a revolution in installation and preventive maintenance*. Easy installation and maintenance and fitted with Kaysun avant-garde TECHNOLOGY. •

Optional WIFI control adding K03 WIFI USB.

Drainage pipe connection from left or right option.

Multisystem compatible unit

Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status.

SCOP 4.0, over European Directive ERP, for a high energy efficiency.

Self-locking option for Heating-Only function.

Display and comfort.

Compatible with wired controllers.

KID-02 S controller included to control unit's work parameters and change its configuration.

Leakage detection system.

Louvers position storage.

buzzer

switch-off

to

improve

ambient

+

EASY ASSEMBLY AND MAINTENANCE

+

WIFI CONTROL (OPTIONAL)

ErP ErP

OPTIONAL WIFI

K03 WIFI USB ACCESSORY

KID-02 S STANDARD

* For further information, please check the Presentation section of this manual.

SINGLE

For further information, please see our Controllers range BMS AND SOFTWARE

INDIVIDUAL

KC-01 S

KC-02.1 H

KCT-02.1 SR

K01-WIFI

37 37


RESIDENTIAL PRODUCT RANGE CASSETTE

PRODIGY R-410A TECHNICAL SPECIFICATIONS SET

KAY-26 DN8

KAY-35 DN8

KAY-52 DN8

KAY-71 DN8

Cooling capacity (min./rated/max.)

kW

1.17/2.64/3.31

1.26/3.52/4.45

1.90/5.28/6.13

2.67/7.03/7.88

Cooling capacity (min./rated/max.)

Kcal/h

1008/2268/2848

1084/3024/3830

1638/4536/5267

2293/6048/6779

W

100/816/1270

110/1153/1720

150/1643/2350

230/2306/3030

SEER

6.7

6.7

6.8

6.4

Cooling energy class

A++

A++

A++

A++

Cold input capacity (min./rated/max.)

Cooling capacity (min./rated/max.)

kW

0.82/2.93/3.72

1.07/3.81/4.86

1.43/5.57/6.74

2.08/7.62/9.14

Cooling capacity (min./rated/max.)

Kcal/h

706/2520/3200

917/3276/4183

1227/4788/5796

1789/6552/7862

W

140/811/1330

170/1055/1740

230/1586/2400

310/2302/3270

SCOP

4.1

4.2

4.1

4.0

Heating efficiency class

A+

A+

A+

A+

SCOP (warm areas)

5.1

5.2

5.5

5.2

A+++

A+++

A+++

A+++

2.12

2.30

3.89

4.95

2.88

2.79

2.78

2.48

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Heat input capacity (min./rated/max.)

Heating energy class (warm areas) Heating capacity -7ºC

kW

COP -7ºC Power supply

V / F / Hz

INDOOR UNIT

KAY-26 DR8

KAY-35 DR8

KAY-52 DR8

KAY-71 DR8

Air flow

3

m /h

486/433/329

550/490/360

810/720/550

1050/970/650

Sound pressure (Silence)

dB (A)

21

23

24

27

Width x Height x Depth

mm

717/302/193

805/302/193

964/325/222

1106/342/232

Net weight

Kg

Power wiring

mm

2

Communication wiring

mm

2

OUTDOOR UNIT Compressor type

7.5

8.2

10.8

14.3

From outdoor

From outdoor

From outdoor

From outdoor

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

KAE-26 DN7

KAE-35 DN7

KAE-52 DN7.1

KAE-71 DN7

Rotary

Rotary

Rotary

Rotary

Outdoor airflow

3

m /h

1900

2000

2200

2700

Sound pressure

dB (A)

55

56

56

61

R-410A

R-410A

R-410A

R-410A

gr

800/15

950/15

1350/15

2000/30

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9(5/8")

Piping max. length

m

25

25

30

50

Pipe height difference

m

10

10

20

25

Width/Height/Depth

mm

770/555/300

800/554/333

800/554/333

845/702/363

Net weight

Kg

26.6

29.1

35.1

48.4

Refrigerant Refrigerant charge / Supplementary charge **

Power wiring

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Communication wiring

mm

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

2 2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)

38 38


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

4.0 R-410A

50/60

SCOP

Hz

24ºC

!

!

1W

24ºC

GENERAL CHARACTERISTICS PRODIGY is the new KAYSUN wall unit. It represents a revolution in installation and preventive maintenance*. Easy installation and maintenance and fitted with Kaysun avant-garde TECHNOLOGY. • Optional WIFI control adding K03 WIFI USB.

• Drainage pipe connection from left or right option.

• Multisystem compatible unit

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. • Display and comfort.

buzzer

switch-off

to

improve

ambient

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Self-locking option for Heating-Only function. • Compatible with wired controllers. • Leakage detection system.

• Louvers position storage.

+

EASY ASSEMBLY AND MAINTENANCE

+

WIFI CONTROL (OPTIONAL)

OPTIONAL WIFI

ErP ErP

K03 WIFI USB ACCESSORY

KID-02 S STANDARD

* For further information, please check the Presentation section of this manual.

SINGLE

For further information, please see our Controllers range BMS AND SOFTWARE

INDIVIDUAL

KC-01 S

KC-02.1 H

KCT-02.1 SR

K01-WIFI

39 39


RESIDENTIAL PRODUCT RANGE CASSETTE

AUREA II R-32 TECHNICAL SPECIFICATIONS SET

KAY-S 26 DR8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

0.82/3.52/4.16

1.73/5.28/6.21

2.58/7.33/8.44

Cooling capacity (min./rated/max.)

kW

1.03/2.64/3.19

Cooling capacity (min./rated/max.)

Kcal/h

886/2270/2743

705/3027/3578

1487/4536/5342

2218/6300/7257

W

70/749/1230

50/1089/1600

120/1538/2390

230/2402/3350

7.1

7.0

6.4

6.4

A++

A++

A++

A++

Cold input capacity (min./rated/max.) SEER Cooling energy class Cooling capacity (min./rated/max.)

kW

0.88/2.93/3.66

0.85/3.81/4.78

1.06/5.57/6.98

1.52/7.62/9.44

Cooling capacity (min./rated/max.)

Kcal/h

756/2520/3148

731/3277/4111

907/4788/5997

1310/6552/8114

W

140/715/1310

130/1050/1710

190/1461/2490

230/2177/3370

SCOP

4.0

4.1

4.0

4.0

Heating efficiency class

A+

A+

A+

A+

SCOP (warm areas)

5.2

5.1

5.1

5.1

A+++

A+++

A+++

A+++

2.15

2.32

3.92

4.99

2.91

2.81

2.80

2.50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Heat input capacity (min./rated/max.)

Heating energy class (warm areas) Heating capacity -7ºC

kW

COP -7ºC Power supply

V / F / Hz

INDOOR UNIT

KAY-S 26 DR8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

Air flow

m3/h

521/429/259

539/478/294

750/505/420

1050/750/560

Sound pressure (Silence)

dB (A)

20

21

21

26

Width/Height/Depth

mm

722/290/187

802/297/189

965/319/215

1080/335/226

Net weight

Kg

7.4

8.2

10.8

12.9

Power wiring

mm2

From outdoor

From outdoor

From outdoor

From outdoor

Communication wiring

mm2

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

KAE-26 DR8

KAE-35 DR8

KAE-52 DR7

KAE-71 DR7

OUTDOOR UNIT Compressor type

Rotary

Rotary

Rotary

Rotary

Outdoor airflow

3

m /h

2000

2000

2100

2700

Sound pressure

dB (A)

55

55

57

59

R-32

R-32

R-32

R-32

gr

700/12

800/12

1250 / 12

1600 / 24

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9(5/8")

Max. piping length

m

25

25

30

50

Pipe height difference

m

10

10

20

25

Width/Height/Depth

mm

770/555/300

770/555/300

800/554/333

845/700/320

Net weight

Kg

26.4

26.5

37

48

Refrigerant Refrigerant charge / Supplementary charge **

Power wiring

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Communication wiring

mm

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

2 2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)

40 40


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

4.0 R-32

SCOP

50/60 Hz

24ºC

!

!

1W

24ºC

GENERAL CHARACTERISTICS AUREA II, the medium-category range of KAYSUN. The AUREA II is characterised by its polyvalent nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies. • Easy installation optional WIFI control adding K03 WIFI USB

• Drainage pipe connection from left or right option.

• MULTISYSTEM compatible unit

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• White translucent smart DISPLAY with information on the equipment and alarm systems status. • Display and comfort.

buzzer

switch-off

to

improve

ambient

• Self-locking option for Heating-Only function. • Leakage detection system.

• KID-02 S controller included to control unit's work parameters and change its configuration. • Louvers position storage.

+ +

OPTIONAL WIFI

WIFI NETWORK CONTROL (OPTIONAL)

POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION

ErP

KID-02 S STANDARD

K03 WIFI USB ACCESSORY

SINGLE

For further information, please see our Controllers range

BMS AND SOFTWARE

K01-WIFI

41 41


RESIDENTIAL PRODUCT RANGE CASSETTE

AUREA II R-410A TECHNICAL SPECIFICATIONS SET

KAY-S 26 DN8

KAY-S 35 DN8

KAY-S 52 DN8

KAY-S 71 DN8

Cooling capacity (min./rated/max.)

kW

1.23/2.64/3.31

1.38/3.52/4.51

1.90/5.28/6.13

2.67/7.03/7.88

Cooling capacity (min./rated/max.)

Kcal/h

1058/2268/2848

1187/3027/3879

1638/4536/5267

2293/6048/6779

W

90/750/1270

100/1088/1740

150/1643/2350

230/2261/3110

SEER

7.4

6.5

6.4

6.3

Cooling energy class

A++

A++

A++

A++

Cold input capacity (min./rated/max.)

Cooling capacity (min./rated/max.)

kW

0.91/2.93/3.75

1.08/3.81/4.92

1.43/5.57/6.74

2.20/7.91/9.29

Cooling capacity (min./rated/max.)

Kcal/h

783/2520/3225

929/3277/4231

1227/4788/5796

1892/6803/7989

W

140/770/1340

170/1025/1760

230/1542/2400

320/2320/3320

SCOP

4.1

4.0

4.1

4.0

Cooling energy class

A+

A+

A+

A+

SCOP (warm areas)

5.4

5.2

5.5

5.2

A+++

A+++

A+++

A+++

2.12

2.30

3.89

4.95

2.88

2.79

2.78

2.48

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KAY-S 26 DR8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

Heat input capacity (min./rated/max.)

Heating energy class (warm areas) Heating capacity -7ºC

kW

COP -7ºC Power supply

V / F / Hz

INDOOR UNIT Airflow

m3/h

521/429/259

539/478/294

750/505/420

1050/750/560

Sound pressure (Silence)

dB (A)

20

21

21

26

Width/Height/Depth

mm

722/290/187

802/297/189

965/319/215

1080/335/226

Net weight

Kg

7.4

8.2

10.8

12.9

Power wiring

mm

From outdoor

From outdoor

From outdoor

From outdoor

Communication wiring

mm

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

OUTDOOR UNIT

KAE-26 DN7

KAE-35 DN7

KAE-52 DN7.1

KAE-71 DN7

Compressor type

Rotary

Rotary

Rotary

Rotary

2 2

Outdoor airflow

m3/h

1900

2000

2200

2700

Sound pressure

dB (A)

55

53

55

60

R-410A

R-410A

R-410A

R-410A

gr

800/15

950/15

1350/15

2000/30

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9 (5/8")

Max. piping length

m

25

25

30

50

Pipe height difference

m

10

10

20

25

Width/Height/Depth

mm

770/555/300

800/554/333

800/554/333

845/702/363

Net weight

Kg

Refrigerant Refrigerant charge / Supplementary charge **

Power wiring

mm

2

Communication wiring

mm

2

26.6

29.1

35.1

48.4

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)

42 42


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

4.0 R-410A

SCOP

50/60 Hz

24ºC

!

!

1W

24ºC

GENERAL CHARACTERISTICS AUREA II, the medium-category range of KAYSUN. The AUREA II is characterised by its polyvalent nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies. • Easy installation optional WIFI control adding K03 WIFI USB

• Drainage pipe connection from left or right option.

• MULTISYSTEM compatible unit

• SCOP 4.0, over European Directive ERP, for a high energy efficiency.

• White translucent smart DISPLAY with information on the equipment and alarm systems status. • Display and comfort.

buzzer

switch-off

to

improve

ambient

• Self-locking option for Heating-Only function. • Leakage detection system.

• KID-02 S controller included to control unit's work parameters and change its configuration. • Louvers position storage.

+ +

OPTIONAL WIFI

WIFI NETWORK CONTROL (OPTIONAL)

POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION

ErP

KID-02 S STANDARD

K03 WIFI USB ACCESSORY

SINGLE

For further information, please see our Controllers range

BMS AND SOFTWARE

K01-WIFI

43 43


RESIDENTIAL PRODUCT RANGE CASSETTE

ONNIX TECHNICAL SPECIFICATIONS SET

KAY-D 26 DN7

KAY-D 35 DN7

KAY-D 52 DN7

Cooling capacity (min./rated/max.)

kW

1.23/2.64/3.30

1.33/3.52/4.47

1.83/5.28/6.12

Cooling capacity (min./rated/max.)

Kcal/h

1057/2270/2838

1144/3027/3844

1574/4541/5263

W

100/712/1260

100/1095/1710

140/1643/2345

SEER

6.8

6.7

6.6

Cooling energy class

A++

A++

A++

Cold input capacity (min./rated/max.)

Cooling capacity (min./rated/max.)

kW

0.85/2.93/3.72

1.04/3.81/4.88

1.40/5.57/6.74

Cooling capacity (min./rated/max.)

Kcal/h

731/2520/3199

894/3276/4197

1204/4790/5796

W

130/792/1320

160/1117/1730

200/1586/2410

SCOP

4.1

4.1

4.0

Heating efficiency class

A+

A+

A+

SCOP (warm areas)

5.3

5.2

5.1

A+++

A+++

A+++

2.31

2.43

3.75

2.76

2.81

2.82

220-240/1/50

220-240/1/50

220-240/1/50

Heat input capacity (min./rated/max.)

Heating energy class (warm areas) Heating capacity -7ºC

kW

COP -7ºC Power supply

V / F / Hz

INDOOR UNIT

KAY-D 26 DN7

KAY-D 35 DN7

KAY-D 52 DN7

Air flow

3

m /h

400/300/240

500/350/270

740/620/480

Sound pressure (Silence)

dB (A)

20

21

21

Width/Height/Depth

mm

897/312/182

897/312/182

1004/350/205

Net weight

Kg

9.5

9.9

13.5

Power wiring

mm

From outdoor

From outdoor

From outdoor

Communication wiring

mm

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

OUTDOOR UNIT

KAE-26 DN7

KAE-35 DN7

KAE-52 DN7.1

Compressor type

Rotary

Rotary

Rotary

2 2

Outdoor airflow

m3/h

1900

2000

2200

Sound pressure

dB (A)

55

56

55

R-410A

R-410A

R-410A

gr

800/15

950/15

1350/15

Liquid pipe diameter

mm (Inch)

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

Ø12.7 (1/2")

Max. piping length

m

25

25

30

Pipe height difference

m

10

10

20

Width/Height/Depth

mm

770/550/300

800/554/333

800/554/333

Net weight

Kg

Refrigerant Refrigerant charge / Supplementary charge **

Power wiring

mm

2

Communication wiring

mm

2

26.6

29.1

35.1

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)

44 44


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

4.0 R-410A

50/60

SCOP

Hz

1W

!

!

GENERAL CHARACTERISTICS Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow and it closes when it switches off to recover its compact appearance.

White translucent smart DISPLAY with information on the equipment and alarm systems status.

A brightness sensor regulates the display's intensity.

KID-02 S controller included to control unit's work parameters and change its configuration.

Louvers position storage.

Optional WIFI control adding K03 WIFI USB.

Drainage pipe connection from left or right option.

SCOP 4.0, over European Directive ERP, for a high energy

efficiency. •

Self-locking option for Heating-Only function.

Leakage detection system.

MULTISYSTEM compatible unit

+ +

WIFI NETWORK CONTROL (OPTIONAL)

BRIGHTNESS SENSOR

ErP ErP

OPTIONAL WIFI

K03 WIFI USB ACCESSORY

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers range

INDIVIDUAL

KID-02 S

KID-02 S STANDARD

BMS AND SOFTWARE

KCT-02.1 SR

KC-01 S

KC-02.1 H

K01-WIFI

45 45


RESIDENTIAL PRODUCT RANGE CASSETTE

DOUBLE FLOW CONSOLE TECHNICAL SPECIFICATIONS KSD-35 DVN11

SET Cooling capacity (min./rated/max.)

kW

0.77/3.52/3.81

Cooling capacity (min./rated/max.)

Kcal/h

662/3027/3277

W

174/1170/1844

Cold input capacity (min./rated/max.) SEER

6.1

Cooling energy class

A++

Cooling capacity (min./rated/max.)

kW

0.46/3.81/4.34

Cooling capacity (min./rated/max.)

Kcal/h

396/3277/3732

W

149/1100/1465

Heat input capacity (min./rated/max.) SCOP

4.0

Heating efficiency class

A+

SCOP (warm areas)

5.1

Heating energy class (warm areas) Heating capacity -7ºC

A+++

kW

COP -7ºC Power supply

3.15 2.69

V / F / Hz

220-240/1/50

KSD-35 DR11

INDOOR UNIT Air flow

3

m /h

512/480/370

Sound pressure (low speed)

dB (A)

35

Width/Height/Depth

mm

700/600/210

Net weight

Kg

14.8

Power wiring

mm

2

Communication wiring

mm

2

From outdoor (3+T)x2.5

KUE-35 DVN11

OUTDOOR UNIT Compressor type

Rotary

Outdoor airflow

3

m /h

2000

Sound pressure

dB (A)

56

Refrigerant Refrigerant charge / Supplementary charge **

R-410A

gr

1050 / 15

Liquid pipe diameter

mm (Inch)

Ø6.35 (1/4")

Gas pipe diameter

mm (Inch)

Ø9.52 (3/8")

Max. piping length

m

25

Pipe height difference

m

10

Width/Height/Depth

mm

800/554/333

Net weight

Kg

29.9

Power wiring

mm2

(2+T)x2.5

Communication wiring

mm2

(3+T)x2.5

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

46 46


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

4.0 R-410A

SCOP

!

GENERAL CHARACTERISTICS The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. It is fitted with the latest technological features, thereby providing users with a high comfort level. •

Double air supply

DC Inverter fan motor with 5 speeds.

Four air intakes

Voltage-free alarm and ON/OFF dry contacts.

Silent unit

Optional wired controller.

ErP

KID-02 S (*) RECOMMENDED

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers range

INDIVIDUAL

KID-02 S

CHOOSE YOUR

CONTROLLER

BMS AND SOFTWARE

KCT-02.1 SR

KC-01 S

KC-02.1 H

K01-WIFI

47 47


RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

MULTISYSTEM SUITE RESIDENTIAL PRODUCT RANGE

“ELEGANCE

Introducing the KAYSUN Multisystem DC Inverter designed to provide comfort and technology to every space. Available in R-410A and R-32. This is a flexible and versatile range that allows multiple combinations with different types of interior units. This range is also affected by the European Directive ERP regarding equipment of less than 8 kW, with which is compliant thanks to the technological development of its components. The whole range is fitted with fans and DC Inverters compressors. These units are the solution for small spaces in which a larger scale installation is not possible. They allow for combinations containing up to 5 indoor units.

AND COMFORT FOR YOUR HOME” The Multisystem range increases the number of indoor units compatible with both R-410A and R-32 refrigerants. In 2018, the R-32 Multisystem range offers a wider ream of possibilities.

OUTDOOR UNITS The residential product range has external units with a robust design designed to make maintenance easier and to protect its main components, so as to extend the useful life of the product.

R-410A

+

STRONG

+

LOW SOUND LEVELS

ErP

APP/WIFI KAYSUN has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.

+

WEEKLY TIMER

+

CHECK

+

BASIC FUNCTIONS K03 WIFI USB ACCESSORY

DOWNLOAD OUR APPLICATION FROM:

www.kaysun.es 48 48

+

PLUG & PLAY


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DISTANCES AND HEIGHT DIFFERENCES TOTAL LENGTH

2X1

3X1

4X1

5X1

40

60

80

80

35

35

MAXIMUM HEIGHT

15

MAXIMUM DISTANCE PER OUTPUT

25

30

R-32 REFRIGERANT UNITS Last year, Frigicoll, by means of its KAYSUN brand, started marketing some of its products fitted with R-32 refrigerant. The new EU regulations encourages the use of alternative gases, such as R-32 refrigerant gas. The R-32 refrigerant has a 675 global warming potential (GWP), a very low rate if compared to the 2,088 GWP produced by R-410A refrigerant. It is more cost-efficient, 10% more suitable and reduces charge volume by 25% because it is more compact. In addition, it offers better performance at an extreme outdoor temperature and is easy to reuse and recycle, as it is made up of a single refrigerant component.

OUTDOOR UNIT

Ducts

AUREA II

DOUBLE FLOW CONSOLE

PRODIGY

CASSETTE

49 49


RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

R-410A

R-410A MULTISYSTEM POWER KW

2.0

2.6

3.5

5.2

7.1

KAY-26 DR8

KAY-35 DR8

KAY-52 DR8

KAY-71 DR8

KAY-S 26 DR8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

KAY-D 26 DN7

KAY-D 35 DN7

KAY-D 52 DN7

INDOOR UNITS PRODIGY

AUREA II

ONNIX

(Page 56)

(Page 58)

(Page 60)

DOUBLE FLOW CONSOLE

(Page 62) KSD-35 DR11

CASSETTE

Ducts

(Page 64) KCI-26 DMR11

KCI-35 DR11

KPD-35 DR11*

KPD-35 DR11

KCI-52 DMR11

(Page 66)

KPD-35 DR11*

*The KPD-35 DR11 unit can be configured for 2kW and 2.6kW

4.2

POWER KW

OUTDOOR UNITS

R-410A

5.2

6.2

7.8

10.5

12.0

(Page 52)

Nยบ OF INDOOR UNITS

2 3

KAM2-42 DN8

KAM2-52 DN7 KAM3-62 DN7

KAM3-78 DN7

4 5 Note: The SUITE MULTISYSTEM range is currently in the process of obtaining the EUROVENT Certification.

50 50

8.0

KAM4-80 DN7

KAM4-105 DN7 KAM5-120 DN7


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

R-32 MULTISYSTEM POWER KW

2.0

2.6

3.5

5.2

7.1

INDOOR UNITS PRODIGY

AUREA II

NEW

(Page 56) KAY-26 DR8

KAY-35 DR8

KAY-52 DR8

KAY-71 DR8

KAY-S 26 DR8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

(Page 58)

DOUBLE FLOW CONSOLE

NEW

(Page 62)

KSD-35 DR11

CASSETTE

NEW

(Page 64) KCI-26 DMR11

Ducts

NEW

KPD-35 DR11*

KCI-35 DR11

KCI-52 DMR11

(Page 66) KPD-35 DR11*

KPD-35 DR11

*The KPD-35 DR11 unit can be configured for 2kW and 2.6kW

4.2

POWER KW

OUTDOOR UNITS

5.2

6.2

7.8

8.0

10.5

12.0

(Page 54)

Nยบ OF INDOOR UNITS

2 3 4 5

KAM2-52 DR7 KAM3-78 DR7 KAM4-105 DR7 KAM5-120 DR7

51 51


RESIDENTIAL PRODUCT RANGE OUTDOOR UNIT

OUTDOOR UNITS

R-410A MULTISYSTEM

KAYSUN MULTISYSTEM outdoor units, with their new appearance and stronger structure, provide greater output with less noise pollution.

+ +

STRONG

QUIET

ErP

TECHNICAL SPECIFICATIONS MODEL

KAM2-42 DN8

KAM2-52 DN7

Cooling capacity

kW

4.10

5.28

6.15

Cooling capacity

Kcal/h

3526

4536

5292

Cooling input

kW

1.25

1.60

1.91

Heating Capacity

kW

4.40

5.57

6.59

Heating Capacity

Kcal/h

3784

4788

5670

Heating input

kW

1.15

1.59

1.78

Power supply

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Rotary

Rotary

Rotary

2100

2100

2700

Compressor type Outdoor airflow

m3/h

Sound pressure

dB (A)

Refrigerant

54

56.5

57.5

R-410A

R-410A

R-410A

Additional refrigerant charge*

gr

1250

1700

2100

Pre-charge metres*

m

10

10

15

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4") x 2

ø6.35 (1/4") x 2

ø6.35 (1/4") x 3

Gas pipe diameter

mm (Inch)

ø9.52 (3/8") x 2

ø9.52 (3/8") x 2

ø9.52 (3/8") x 3

Piping max. length

m

40

40

60

Piping max. length (1 indoor unit)

m

25

25

30

Height difference between indoor and outdoor units

m

15

15

15

Height difference between indoor units

m

10

10

10

Width/Height/Depth

mm

800/554/333

800/554/333

845/702/363

Net weight

Kg

31.5

36

47.0

2

2

3

Maximum number of indoor units Power wiring

2

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Communication wiring

mm2

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating) *To calculate the additional load necessary for these units, we applied the following formula: ADDITIONAL LOAD (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE OF ¼” x 15 Grams). (TOTAL LENGTH OF LIQUID LINE OF 3/8” x 30 Grams) - (TOTAL LENGTH OF FACTORY PRELOAD x 15 Grams) Note 1: Standard performance data; definitive performance data depend on the combination of indoor units. Note 2: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. 52

KAM3-62 DN7

52 52


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC R-410A

KAM3-78 DN7

INVERTER

KAM4-80 DN7

KAM4-105 DN7

7.91

8.21

10.55

12.31

6804

7056

9072

10584

!

DC

INVERTER

OUTDOOR

KAM5-120 DN7

2.46

2.55

3.62

3.82

8.21

8.79

11.14

12.60

7056

7560

9576

10836

2.27

2.43

3.17

3.31

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Rotary

Rotary

Rotary

Rotary

3500

3800

5500

5500

59.5

60

63.5

62

R-410A

R-410A

R-410A

R-410A

2100

2400

3000

3600

15

20

20

25

ø6.35 (1/4") x 3

ø6.35 (1/4") x 4

ø6.35 (1/4") x 4

ø6.35 (1/4") x 5

ø9.52 (3/8") x 3

ø9.52 (3/8”) x 3 + ø12.7 (1/2”) x 1

ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1

ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2

60

80

80

80

30

35

35

35

15

15

15

15

10

10

10

10

845/702/363

946/810/410

946/810/410

946/810/410

52.7

67.6

70.0

76.0

3

4

4

5

(2+T)x4

(2+T)x4

(2+T)x6

(2+T)x6

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

53 53


RESIDENTIAL PRODUCT RANGE OUTDOOR UNIT

OUTDOOR UNITS

R-32 MULTISYSTEM

TECHNICAL SPECIFICATIONS MODEL

KAM2-52 DR7

KAM3-78 DR7

KAM4-105 DR7 KAM5-120 DR7

Cooling capacity

kW

5.28

7.91

10.55

12.31

Cooling capacity

Kcal/h

4536

6804

9072

10584

Cooling input

kW

7.75

2.47

3.52

3.80

Heating Capacity

kW

5.57

8.21

11.40

12.60

Heating Capacity

Kcal/h

4788

7056

9576

10836

Heating input

kW

1.45

2.25

2.88

3.30

Power supply

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Rotary

Rotary

Rotary

Rotary

Compressor type Outdoor airflow

m3/h

2200

2700

4000

3850

Sound pressure

dB (A)

56

59

63

62

R-32

R-32

R-32

R-32

Refrigerant Additional refrigerant charge*

gr

1300

1570

2100

2400

Pre-charge metres*

m

15

22.5

30

37.5

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4") x 2

ø6.35 (1/4") x 3

ø6.35 (1/4") x 4

ø6.35 (1/4") x 5

Gas pipe diameter

mm (Inch)

ø9.52 (3/8") x 2

ø9.52 (3/8") x 3

ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1

ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2

Max. piping length

m

40

60

80

80

Piping max. length (1 indoor unit)

m

25

30

35

35

Height difference between indoor and outdoor units

m

15

15

15

15

Height difference between indoor units

m

10

10

10

10

Width/Height/Depth

mm

800/554/333

845/702/363

946/810/410

946/810/410

Net weight

Kg

36.0

53.0

68.8

73.3

2

3

4

5

Maximum number of indoor units Power wiring

mm2

(2+T)x2.5

(2+T)x4

(2+T)x6

(2+T)x6

Communication wiring

mm2

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

*To calculate the additional load necessary for these units, we applied the following formula: ADDITIONAL LOAD (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE OF ¼” x 12 Grams). (TOTAL LENGTH OF LIQUID LINE OF 3/8” x 24 Grams) - (TOTAL LENGTH OF FACTORY PRELOAD x 12 Grams) Note 1: Standard performance data; definitive performance data depend on the combination of indoor units. Note 2: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

54 54


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

INVERTER

R-32

!

DC

INVERTER

OUTDOOR

KAYSUN MULTISYSTEM outdoor units, with their strong structure, provide greater output with less noise pollution.

+ +

STRONG

QUIET

ErP

55 55


RESIDENTIAL PRODUCT RANGE INDOOR UNIT

PRODIGY MULTI TYPE TECHNICAL SPECIFICATIONS MODEL

KAY-26 DR8

KAY-35 DR8

KAY-52 DR8

KAY-71 DR8

Cooling capacity

kW

2.63

3.51

5.27

7.3

Cooling capacity

Kcal/h

2262

3019

4532

6278

Heating Capacity

kW

2.93

4.1

5.56

7.61

Heating Capacity

Kcal/h

2520

3526

4781

6545

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Air flow

m³/h

486/433/329

550/490/360

810/720/550

1050/970/650

Sound pressure (Silence)

dB (A)

22

23

24

27

Inlet liquid pipe liquid

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9(5/8")

Width/Height/Depth

mm

717/302/193

805/302/193

964/325/222

1106/342/232

Net weight

Kg

7.5

8.2

10.8

14.3

Power wiring

mm2

From outdoor

From outdoor

From outdoor

From outdoor

Communication wiring

mm2

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

Power supply

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

56 56


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

24ºC

INDOOR

24ºC

INVERTER

R-32

R-410A

GENERAL CHARACTERISTICS PRODIGY, is the new KAYSUN wall unit. It represents a revolution in installation and preventive maintenance*. Easy installation and maintenance and fitted with Kaysun avant-garde technology. • KID-02 S controller included to control unit's work parameters and change its configuration.

• Optional WIFI control adding K03 WIFI USB. • Compatible with 1x1 systems. • White translucent smart DISPLAY with information on the equipment and alarm systems status. • The display and buzzer have a switch-off option that can be activated if they annoy the user.

+ +

• Louvers position storage. • Drainage pipe connection from left or right option. • Compatible with wired controllers.

WIFI NETWORK CONTROL (OPTIONAL)

EASY ASSEMBLY AND MAINTENANCE

ErP

KID-02 S STANDARD

COMPATIBLE WITH K03 WIFI USB ACCESSORY

MULTISYSTEM OUTDOOR UNITS

OPTIONAL WIFI

see pag. 52 for R-410A see pag. 54 for R-32

* For further information, please check the Presentation section of this manual.

SINGLE

For further information, please see our Controllers range

INDIVIDUAL

KC-01 S

BMS AND SOFTWARE

KC-02.1 H

KCT-02.1 SR

K01-WIFI

57 57


RESIDENTIAL PRODUCT RANGE INDOOR UNIT

AUREA II

MULTI TYPE

TECHNICAL SPECIFICATIONS MODEL

KAY-S 26 DR8

KAY-S 35 DR8

KAY-S 52 DR8

KAY-S 71 DR8

Cooling capacity

kW

2.69

3.51

5.27

7.3

Cooling capacity

Kcal/h

2313

3019

4532

6278

Heating capacity

kW

2.93

3.81

5.57

7.64

Heating capacity

Kcal/h

2520

3276

4788

6552

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Airflow

m3/h

521/429/259

539/478/294

750/505/420

1050/750/560

Sound pressure (Silence)

dB (A)

20

21

23

26

Width/Height/Depth

mm

722/290/187

802/297/189

965/319/215

1080/335/226

Net weight

Kg

7.4

8.2

9

12

Power supply

Power wiring

mm2

From outdoor

From outdoor

From outdoor

From outdoor

Communication wiring

mm

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

58 58


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

24ºC

INVERTER

R-32

R-410A

24ºC

INDOOR

GENERAL CHARACTERISTICS AUREA II, the medium-category range of KAYSUN. The AUREA II is characterised by its polyvalent nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies. • Optional WIFI control adding K03 WIFI USB.

and change its configuration.

• Compatible with 1x1 systems.

• Louvers position storage.

• White translucent smart DISPLAY with information on the equipment and alarm systems status.

• Drainage pipe connection from left or right option.

• The display and buzzer have a switch-off option that can be activated if they annoy the user. • KID-02 S controller included to control unit's work parameters

+ +

20 dB SOUND PRESSURE

WIFI NETWORK CONTROL (OPTIONAL)

KID-02 S ErP

STANDARD

COMPATIBLE WITH K03 WIFI USB ACCESSORY OPTIONAL WIFI

MULTISYSTEM OUTDOOR UNITS see pag. 52 for R-410A see pag. 54 for R-32

SINGLE BMS AND SOFTWARE

K01-WIFI

59 59


RESIDENTIAL PRODUCT RANGE INDOOR UNIT

ONNIX

MULTI TYPE

TECHNICAL SPECIFICATIONS MODEL

KAY-D 26 DN7

KAY-D 35 DN7

KAY-D 52 DN7

Cooling capacity

kW

2.64

3.52

5.28

Cooling capacity

Kcal/h

2268

3024

4536

Heating Capacity

kW

2.93

3.81

5.57

Heating Capacity

Kcal/h

2520

3276

4788

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Air flow

m3/h

400/300/240

500/350/270

740/620/480

Sound pressure (Silence)

dB (A)

20

21

21

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

Width/Height/Depth

mm

897/182/312

897/182/312

1004/205/350

Net weight

Kg

9.5

9.9

13.5

Power wiring

mm2

From outdoor

From outdoor

From outdoor

Communication wiring

mm2

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

Power supply

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

60 60


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

INVERTER

R-410A

INDOOR

GENERAL CHARACTERISTICS Onnix, the top-end range of KAYSUN in wall-mounted units. Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow and it closes when it switches off to recover its compact appearance. • A brightness sensor regulates the display's intensity.

• Compatible with 1x1 systems and multisystems.

• KID-02 S controller included to control unit's work parameters and change its configuration.

• Drainage pipe connection from left or right option.

• Louvers position storage. • Optional WIFI control adding K03 WIFI USB.

+ +

20 dB SOUND PRESSURE

WIFI NETWORK CONTROL (OPTIONAL)

ErP

KID-02 S STANDARD

COMPATIBLE WITH K03 WIFI USB ACCESSORY

MULTISYSTEM OUTDOOR UNITS

OPTIONAL WIFI

see pag. 52 for R-410A

SINGLE

For further information, please see our Controllers range

INDIVIDUAL

KC-01 S

BMS AND SOFTWARE

KC-02.1 H

KCT-02.1 SR

K01-WIFI

61 61


RESIDENTIAL PRODUCT RANGE INDOOR UNIT

DOUBLE FLOW CONSOLE

MULTI TYPE

TECHNICAL SPECIFICATIONS KSD-35 DR11

MODEL Cooling capacity

kW

3.46

Cooling capacity

Kcal/h

2976

Heating Capacity

kW

3.75

Heating Capacity

Kcal/h

2976

V / F / Hz

220-240/1/50

Air flow

m³/h

516/480/370

Sound pressure (low speed)

dB (A)

35

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

Width/Height/Depth

mm

700/600/210

Net weight

Kg

15

Power wiring

mm2

From outdoor

Communication wiring

mm2

(3+T)x2.5

Power supply

*Sound pressure in “Silence” mode. Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

62

62 62


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

INVERTER

R-32

R-410A

INDOOR

GENERAL CHARACTERISTICS

The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. This unit has the best technological features and its adaptability cover the needs of every user. • DC INVERTER FAN MOTOR.

• Easy installation.

• Double air supply and four air intakes.

• Optional wired controller.

• Voltage-free alarm and ON/OFF dry contacts.

+

KID-02 S

DOUBLE AIR INTAKE

ErP

STANDARD

COMPATIBLE WITH

MULTISYSTEM OUTDOOR UNITS see pag. 52 for R-410A see pag. 54 for R-32

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers range

INDIVIDUAL

KID-02 S

CHOOSE YOUR

CONTROLLER

BMS AND SOFTWARE

KCT-02.1 SR

KC-01 S

KC-02.1 H

K01-WIFI

63 63


RESIDENTIAL PRODUCT RANGE INDOOR UNIT

CASSETTE

MULTI TYPE

TECHNICAL SPECIFICATIONS MODEL

KCI-26 DMR11

KCI-35 DR11

KCI-52 DMR11

Cooling capacity

kW

2.64

3.52

4.98

Cooling capacity

Kcal/h

2268

3024

4284

Heating Capacity

kW

2.93

4.1

5.57

Heating Capacity

Kcal/h

2520

3528

4788

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Air flow

3

m /h

580/500/450

617/504/416

680/560/500

Sound pressure (low speed)

dB (A)

29

35

41

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

Width/Height/Depth

mm

570/260/570

570/260/570

570/260/570

Net weight

Kg

14.7

16

16.1

Panel width/height/depth

mm

647/50/647

647/50/647

647/50/647

Panel net weight

Kg

2.5

2.5

2.5

Power wiring

mm2

From outdoor

From outdoor

From outdoor

Communication wiring

mm2

(3+T)x2.5

(3+T)x2.5

(3+T)x2.5

Power supply

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

64

64 64


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

INVERTER

R-32

R-410A

INDOOR

GENERAL CHARACTERISTICS

The Cassette units have an impeccable design. Its 360º airflow provides user with maximum comfort covering every single corner of the room. • They are fitted with an up to 500 mm high standard condensation pump.

• The Cassette 600x600 type units supply 10 % to 15 % of outdoor airflow directly to the unit return system.

• Voltage-free alarm and ON/OFF dry contacts.

• The electric box is located at the lower side of the unit to get a more compact size and embed the unit easily in the ceiling.

• The right and left sides of these units' body are designed to connect the necessary piping to air-condition an adjacent room.

+

OUTDOOR AIR SUPPLY (10-15%)

+

500mm CONDENSATION PUMP

KID-02 S RECOMMENDED ErP

COMPATIBLE WITH NEW

MULTISYSTEM OUTDOOR UNITS

OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

see pag. 52 for R-410A see pag. 54 for R-32

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers range

INDIVIDUAL

CENTRALISED NEW

KID-02 S

CHOOSE YOUR

CONTROLLER

KCT-02.1 SR

KC-02.1 H

KCCT-64 I (B)

KC-01 S

KCCT-64 IPS

NEW

KCCT-384 IPS

KCC-64 WEB

K01-KNX

K01-WIFI

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

65 65 65


RESIDENTIAL PRODUCT RANGE INDOOR UNIT

Ducts

MULTI TYPE

NEW

TECHNICAL SPECIFICATIONS MODEL

KPD-35 DR11

Cooling capacity

kW

3.52

Cooling capacity

Kcal/h

3024

Heating Capacity

kW

3.81

Heating Capacity

Kcal/h

3276

V / F / Hz

220-240/1/50

m3/h

600/480/300

Maximum pressure available

Pa

60

Sound pressure (low speed)

dB (A)

27.5

Liquid pipe diameter

mm (Inch)

ø6.35 (1/4")

Gas pipe diameter

mm (Inch)

ø9.52 (3/8")

Width/Height/Depth

mm

975/200/450

Net weight

Kg

18

Power supply Air flow

Power wiring

mm

From outdoor

Communication wiring

mm2

(3+T)x2.5

2

CAN BE CONFIGURED FOR 2 & 2.6 kW Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.

66

66 66

33


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

DC

INVERTER

R-32

INDOOR

R-410A

GENERAL CHARACTERISTICS The tilted evaporator of the KAYSUN Ducts provides them with a very slim design. This feature allows for installing Ducts units in areas where the false ceiling is too narrow. The KC-03.1 SPS wired controller includes a new feature that allows selecting static pressure automatically. This unit can also be installed in vertical position (floor standing). • The filter is easy to remove even when piping is in place. • All units include an air inlet/outlet pre-installation to facilitate the fitting of the tubes that guarantee air circulation. • Outdoor air intake to treat air with indoor unit's battery and blow it into the room through the air line. • The electric box of Duct type indoor units is removable up to 1 metre.

• They are fitted with an up to 500 mm high standard condensation pump. • Voltage-free alarm and ON/OFF dry contacts. • Horizontal and vertical installation. • The KC-03.1 SPS controller allows adjusting the available pressure automatically.

+ ErP

+ +

Compatible with

OUTDOOR AIR INTAKE

750mm CONDENSATION PUMP

HORIZONTAL AND VERTICAL INSTALLATION

KC-03.1 SPS RECOMMENDED

COMPATIBLE WITH NEW

MULTISYSTEM OUTDOOR UNITS

OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

see pag. 52 for R-410A see pag. 54 for R-32

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers Range

INDIVIDUAL

CENTRALISED NEW

KID-02 S

CHOOSE YOUR

CONTROLLER

KCT-02.1 SR

KC-03 SPS

KC-03.1 SPS

KC-02.1 H

KC-01 S

KCCT-64 I (B)

KCCT-64 IPS

NEW

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

67 67 67


RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS

COMBINED SYSTEMS KAM2-42 DN8

R-410A MULTISYSTEM

x1

x2

20

20+20

26

20+26

35

20+35

52

26+26 26+35

KAM2-52 DN7

x1

x2

20

20+20

26

20+26

35

20+35

52

20+52 26+26 26+35 26+52 35+35

68 68


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

COMBINATIONS

1x2

EER (W/W)

SEER

ENERGY CLASS

UNIT A

UNIT B

20

20

2.05

2.05

1.76

4.10

4.54

0.42

1.24

1.43

3.30

6.10

A++

20

26

1.79

2.31

1.76

4.10

4.54

0.42

1.24

1.43

3.30

6.10

A++

MINIMUM

RATED

MAXIMUM

MINIMUM

RATED

MINIMUM RATED CAPACITY

20

35

1.51

2.59

1.76

4.10

4.54

0.42

1.23

1.43

3.32

6.10

A++

26

26

2.05

2.05

1.76

4.10

4.54

0.42

1.24

1.43

3.30

6.10

A++

26

35

1.76

2.34

1.76

4.10

4.54

0.42

1.23

1.43

3.32

6.10

A++

RATED CAPACITY (kW)

HEATING POWER (kW)

UNIT B

POWER INPUT (kW)

COP (W/W)

ENERGY CLASS

SCOP

COP -7

UNIT A

UNIT B

UNIT A

20

20

2.20

2.20

1.89

4.40

4.87

0.39

1.16

1.33

3.80

4.00

A+

3.15

20

26

1.93

2.48

1.89

4.40

4.87

0.39

1.16

1.33

3.80

4.00

A+

3.15

MINIMUM

RATED

MAXIMUM MINIMUM

RATED

RATED CAPACITY

MAXIMUM

20

35

1.66

2.84

1.89

4.50

4.98

0.39

1.19

1.33

3.78

4.00

A+

3.13

26

26

2.20

2.20

1.89

4.40

4.87

0.39

1.16

1.33

3.80

4.00

A+

3.15

26

35

1.93

2.57

1.89

4.50

4.98

0.39

1.19

1.33

3.78

4.00

A+

3.13

UNIT A

UNIT B

RATED CAPACITY (kW) UNIT A

UNIT B

HEATING CAPACITY (kW) MINIMUM

RATED

EER (W/W)

POWER INPUT (kW) MAXIMUM

MINIMUM

RATED

SEER

ENERGY CLASS

RATED CAPACITY

MAXIMUM

20

20

2.10

2.10

2.08

4.20

5.51

0.59

1.27

2.16

3.31

6.20

A++

20

26

2.06

2.64

2.08

4.70

5.72

0.59

1.46

2.16

3.23

6.20

A++ A++

20

35

1.95

3.35

2.08

5.30

6.29

0.59

1.82

2.16

2.91

6.10

20

52

1.51

3.92

2.08

5.40

6.34

0.59

1.77

2.16

3.05

6.10

A++

26

26

2.60

2.60

2.08

5.20

6.29

0.59

1.79

2.16

2.91

6.30

A++

26

35

2.31

3.09

2.08

5.40

6.29

0.59

1.83

2.16

2.95

6.30

A++

26

52

1.80

3.60

2.08

5.40

6.34

0.59

1.77

2.16

3.05

6.30

A++

35

35

2.70

2.70

2.08

5.40

6.29

0.59

1.79

2.16

3.01

6.30

A++

COMBINATIONS

1x2

POWER INPUT (kW)

UNIT B

COMBINATIONS

1x2

COOLING CAPACITY (kW)

UNIT A

COMBINATIONS

1x2

RATED CAPACITY (kW)

RATED CAPACITY (kW)

UNIT A

UNIT B

UNIT A

UNIT B

HEATING POWER (kW) MINIMUM

RATED

COP (W/W)

INPUT INPUT (kW) MAXIMUM MINIMUM

RATED

MAXIMUM

SCOP

ENERGY CLASS

COP -7

RATED RATED

20

20

2.50

2.50

2.20

5.00

5.94

0.50

1.30

1.85

3.85

4.00

A+

3.19

20

26

2.32

2.98

2.20

5.30

6.05

0.50

1.39

1.85

3.81

4.00

A+

3.16

20

35

2.03

3.47

2.20

5.50

6.66

0.50

1.48

1.85

3.71

4.00

A+

3.07

20

52

1.57

4.07

2.20

5.60

6.71

0.50

1.47

1.85

3.81

4.00

A+

3.16

26

26

2.75

2.75

2.20

5.50

6.66

0.50

1.48

1.85

3.71

4.00

A+

3.07

26

35

2.40

3.20

2.20

5.60

6.66

0.50

1.49

1.85

3.75

4.00

A+

3.11

26

52

1.87

3.73

2.20

5.60

6.71

0.50

1.47

1.85

3.81

4.00

A+

3.16

35

35

2.80

2.80

2.20

5.60

6.66

0.50

1.49

1.85

3.75

4.00

A+

3.11

69 69


RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS

COMBINED SYSTEMS KAM3-62 DN7

R-410A MULTISYSTEM

x1

x2

x3

20

20+20

20+20+20

26

20+26

20+20+26

35

20+35

20+20+35

52

20+52

20+26+26

26+26

20+26+35

26+35

26+26+26

26+52

26+26+35

35+35

KAM3-78 DN7

x1

x2

x3

20

20+20

20+20+20

26

20+26

20+20+26

35

20+35

20+20+35

52

20+52

20+20+52

26+26

20+26+26

26+35

20+26+35

26+52

20+26+52

35+35

20+35+35

35+52

26+26+26 26+26+35 26+35+35 35+35+35

70 70


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

RATED CAPACITY (kW)

COMBINATIONS

ENERGY CLASS

UNIT B

UNIT C

20

20

20

2.03

2.03

2.03

2.44

6.10

7.20

0.68

1.90

2.38

3.21

6.10

20

20

26

1.92

1.92

2.47

2.44

6.30

7.26

0.68

1.96

2.38

3.22

6.10

A++

20

20

35

1.70

1.70

2.91

2.44

6.30

7.32

0.68

1.94

2.38

3.24

6.10

A++

20

26

26

1.76

2.27

2.27

2.44

6.30

7.32

0.68

1.94

2.38

3.24

6.10

A++

20

26

35

1.58

2.03

2.70

2.44

6.30

7.32

0.68

1.94

2.38

3.24

6.10

A++

26

26

26

2.10

2.10

2.10

2.44

6.30

7.32

0.68

1.94

2.38

3.24

6.10

A++

26

26

35

1.89

1.89

2.52

2.44

6.30

7.32

0.68

1.94

2.38

3.24

6.10

A++

MINIMUM

RATED CAPACITY (kW)

UNIT B

UNIT C

UNIT A

UNIT B

MAXIMUM MINIMUM

HEATING POWER (kW)

POWER INPUT (kW)

RATED

RATED

UNIT C MINIMUM

MAXIMUM MINIMUM

MAXIMUM RATED CAPACITY

COP (W/W)

SCOP

A++

ENERGY CLASS

COP -7

RATED CAPACITY

MAXIMUM

20

20

20

2.20

2.20

2.20

2.64

6.60

7.79

0.64

1.78

2.22

3.71

4.00

A+

2.90

20

20

26

2.02

2.02

2.60

2.64

6.65

7.79

0.64

1.79

2.22

3.71

4.00

A+

2.90

20

20

35

1.80

1.80

3.09

2.64

6.70

7.92

0.64

1.81

2.22

3.71

4.00

A+

2.95

20

26

26

1.88

2.41

2.41

2.64

6.70

7.92

0.64

1.81

2.22

3.71

4.00

A+

2.95

20

26

35

1.68

2.15

2.87

2.64

6.70

7.92

0.64

1.81

2.22

3.71

4.00

A+

2.95

26

26

26

2.23

2.23

2.23

2.64

6.70

7.92

0.64

1.81

2.22

3.71

4.00

A+

2.95

26

26

35

2.01

2.01

2.68

2.64

6.70

7.92

0.64

1.81

2.22

3.71

4.00

A+

2.95

RATED CAPACITY (kW)

COMBINATIONS UNIT A

UNIT B

UNIT C

UNIT A

UNIT B

UNIT C

MINIMUM

HEATING CAPACITY (kW)

POWER INPUT (kW)

RATED

RATED

MAXIMUM MINIMUM

EER (W/W)

SEER

ENERGY CLASS

MAXIMUM RATED CAPACITY

20

20

20

2.43

2.43

2.43

2.77

7.30

8.69

0.76

2.27

2.93

3.21

6.60

A++

20

20

26

2.25

2.25

2.90

2.77

7.40

8.69

0.76

2.31

2.93

3.21

6.60

A++

20

20

35

2.13

2.13

3.65

2.77

7.90

8.69

0.76

2.46

2.93

3.21

6.60

A++

20

20

52

1.73

1.73

4.44

2.77

7.90

8.69

0.76

2.44

2.93

3.24

6.60

A++

20

26

26

2.13

2.74

2.74

2.77

7.60

8.69

0.76

2.37

2.93

3.21

6.60

A++

20

26

35

1.98

2.54

3.39

2.77

7.90

8.69

0.76

2.46

2.93

3.21

6.60

A++

20

26

52

1.63

2.09

4.18

2.77

7.90

8.69

0.76

2.44

2.93

3.24

6.60

A++

20

35

35

1.78

3.06

3.06

2.77

7.90

8.69

0.76

2.45

2.93

3.23

6.60

A++ A++

26

26

26

2.63

2.63

2.63

2.77

7.90

8.69

0.76

2.46

2.93

3.21

6.60

26

26

35

2.37

2.37

3.16

2.77

7.90

8.69

0.76

2.45

2.93

3.23

6.60

A++

26

35

35

2.15

2.87

2.87

2.77

7.90

8.69

0.76

2.44

2.93

3.24

6.60

A++

35

35

35

2.63

2.63

2.63

2.77

7.90

8.69

0.76

2.44

2.93

3.24

6.60

A++

RATED CAPACITY (kW)

COMBINATIONS UNIT A

1x3

RATED

SEER

UNIT A

UNIT A

1x3

RATED

EER (W/W)

UNIT C

COMBINATIONS

1x3

INPUT INPUT (kW)

UNIT B

UNIT A

1x3

HEATING CAPACITY (kW)

UNIT C MINIMUM

HEATING POWER (kW)

INPUT INPUT (kW)

RATED

RATED

MAXIMUM MINIMUM

COP (W/W) MAXIMUM

SCOP

ENERGY CLASS

COP -7

RATED CAPACITY

UNIT B

UNIT C

UNIT A

UNIT B

20

20

20

2.27

2.27

2.27

2.87

6.80

9.02

0.70

1.88

2.70

3.61

4.00

A+

2.99

20

20

26

2.13

2.13

2.74

2.87

7.00

9.02

0.70

1.94

2.70

3.61

4.00

A+

2.99

20

20

35

2.13

2.13

3.65

2.87

7.90

9.02

0.70

2.19

2.70

3.61

4.00

A+

2.99

20

20

52

1.82

1.82

4.67

2.87

8.30

9.02

0.70

2.27

2.70

3.65

4.00

A+

3.02

20

26

26

2.21

2.84

2.84

2.87

7.90

9.02

0.70

2.19

2.70

3.61

4.00

A+

2.99

20

26

35

2.05

2.64

3.51

2.87

8.20

9.02

0.70

2.27

2.70

3.61

4.00

A+

2.99

20

26

52

1.71

2.20

4.39

2.87

8.30

9.02

0.70

2.27

2.70

3.65

4.00

A+

3.02

20

35

35

1.87

3.21

3.21

2.87

8.30

9.02

0.70

2.29

2.70

3.62

4.00

A+

3.00

26

26

26

2.73

2.73

2.73

2.87

8.20

9.02

0.70

2.27

2.70

3.61

4.00

A+

2.99

26

26

35

2.49

2.49

3.32

2.87

8.30

9.02

0.70

2.29

2.70

3.62

4.00

A+

3.00

26

35

35

2.26

3.02

3.02

2.87

8.30

9.02

0.70

2.27

2.70

3.65

4.00

A+

3.02

35

35

35

2.77

2.77

2.77

2.87

8.30

9.02

0.70

2.27

2.70

3.65

4.00

A+

3.02

71 71


RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS

COMBINED SYSTEMS KAM4-80 DN7

R-410A MULTISYSTEM

x1

x2

20

20+20

20+20+20

20+20+20+20

26

20+26

20+20+26

20+20+20+26

35

20+35

20+20+35

20+20+20+35

52

20+52

20+20+52

20+20+20+52

71

x3

20+71

20+20+71

20+20+26+26

26+26

20+26+26

20+20+26+35

26+35

20+26+35

20+20+35+35

26+52

20+26+52

20+26+26+26

26+71

20+35+35

20+26+26+35

35+35

20+35+52

20+26+35+35

35+52

26+26+26

26+26+26+26

35+71

26+26+35

26+26+26+35

52+52

26+26+52 26+35+35 26+35+52 35+35+35

72 72

x4


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

RATED CAPACITY (KW)

COMBINED SYSTEMS UNIT A

1x4

UNIT B

UNIT C

UNIT D

UNIT A

UNIT B

UNIT C

MIN.

RATED

MAX.

MIN.

RATED

MAX.

SEER

ENERGY CLASS

RATED CAPACITY

20

20

20

20

2.05

2.05

2.05

2.05

3.04

8.21

9.93

0.84

2.47

3.09

3.32

6.8

A++

20

20

20

26

1.92

1.92

1.92

2.46

3.04

8.21

9.93

0.84

2.47

3.09

3.32

6.8

A++

20

20

20

35

1.74

1.74

1.74

2.99

3.04

8.21

9.93

0.84

2.47

3.09

3.32

6.8

A++

20

20

20

52

1.47

1.47

1.47

3.79

3.04

8.21

9.93

0.84

2.50

3.09

3.28

6.8

A++

20

20

26

26

1.80

1.80

2.31

2.31

3.04

8.21

9.93

0.84

2.47

3.09

3.32

6.8

A++

20

20

26

35

1.64

1.64

2.11

2.81

3.04

8.21

9.93

0.84

2.49

3.09

3.30

6.8

A++

20

20

35

35

1.51

1.51

2.59

2.59

3.04

8.21

9.93

0.84

2.50

3.09

3.29

6.8

A++

20

26

26

26

1.69

2.17

2.17

2.17

3.04

8.21

9.93

0.84

2.48

3.09

3.31

6.8

A++

20

26

26

35

1.55

2.00

2.00

2.66

3.04

8.21

9.93

0.84

2.50

3.09

3.29

6.8

A++

20

26

35

35

1.44

1.85

2.46

2.46

3.04

8.21

9.93

0.84

2.50

3.09

3.28

6.8

A++

26

26

26

26

2.05

2.05

2.05

2.05

3.04

8.21

9.93

0.84

2.50

3.09

3.29

6.8

A++

26

26

26

35

1.89

1.89

1.89

2.53

3.04

8.21

9.93

0.84

2.50

3.09

3.28

6.8

A++

SCOP

ENERGY CLASS COP -7

RATED CAPACITY (KW)

COMBINED SYSTEMS UNIT A

1x4

UNIT D

EER W/W

POWER INPUT (kW)

COOLING CAPACITY (KW)

UNIT B

UNIT C

UNIT D

UNIT A

UNIT B

HEATING CAPACITY (KW)

UNIT C

UNIT D

MIN.

RATED

MAX.

COP W/W

INPUT INPUT (kW) MIN.

RATED

MAX.

RATED CAPACITY

20

20

20

20

2.20

2.20

2.20

2.20

3.26

8.80

10.65

0.83

2.44

3.05

3.61

4.0

A++

2.99

20

20

20

26

2.08

2.08

2.08

2.67

3.26

8.90

10.65

0.83

2.47

3.05

3.61

4.0

A++

2.99

20

20

20

35

1.91

1.91

1.91

3.27

3.26

9.00

10.65

0.83

2.49

3.05

3.61

4.0

A++

2.99

20

20

20

52

1.63

1.63

1.63

4.20

3.26

9.10

10.65

0.83

2.52

3.05

3.61

4.0

A++

2.99

20

20

26

26

1.95

1.95

2.50

2.50

3.26

8.90

10.65

0.83

2.47

3.05

3.61

4.0

A++

2.99

20

20

26

35

1.80

1.80

2.31

3.09

3.26

9.00

10.65

0.83

2.49

3.05

3.61

4.0

A++

2.99

20

20

35

35

1.68

1.68

2.87

2.87

3.26

9.10

10.65

0.83

2.52

3.05

3.61

4.0

A++

2.99

20

26

26

26

1.83

2.36

2.36

2.36

3.26

8.90

10.65

0.83

2.47

3.05

3.61

4.0

A++

2.99

20

26

26

35

1.70

2.19

2.19

2.92

3.26

9.00

10.65

0.83

2.49

3.05

3.61

4.0

A++

2.99

20

26

35

35

1.59

2.05

2.73

2.73

3.26

9.10

10.65

0.83

2.52

3.05

3.61

4.0

A++

2.99

26

26

26

26

2.23

2.23

2.23

2.23

3.26

8.90

10.65

0.83

2.47

3.05

3.61

4.0

A++

2.99

26

26

26

35

2.10

2.10

2.10

2.80

3.26

9.10

10.65

0.83

2.52

3.05

3.61

4.0

A++

2.99

73 73


RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS

COMBINED SYSTEMS KAM4-105 DN7

R-410A MULTISYSTEM

x1

x2

x3

x4

20

20 +20

20 +20 +20

20 +20 +20 +20

26

20 +26

20 +20 +26

20 +20 +20 +26

35

20 +35

20 +20 +35

20 +20 +20 +35

52

20 +52

20 +20 +52

20 +20 +20 +52

71

20 +71

20 +20 +71

20 +20 +20 +71

26+26

20 +26 +26

20 +20 +26 +26

26+35

20 +26 +35

20 +20 +26 +35

26+52

20 +26 +52

20 +20 +26 +52

26+71

20 +26 +71

20 +20 +26 +71

35+35

20 +35 +35

20 +20 +35 +35

35+52

20 +35 +52

20 +20 +35 +52

35+71

20 +35 +71

20 +20 +52 +52

52+52

20 +52 +52

20 +26+26+26

26+26+26

20 +26+26+35

26+26+35

20 +26+26+52

26+26+52

20 +26+26+71

26+35+35

20 +26+35+35

26+35+52

20 +26+35+52

26+35+71

20 +26+52+52

26+52+52

20 +35+35+35

35+35+35

20 +35+35+52

35+35+52

26+26+26+26

35+35+71

26+26+26+35

35+52+52

26+26+26+52 26+26+35+35 26+26+35+52 26+35+35+35 26+35+35+52 35+35+35+35

74 74


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

COMBINED SYSTEMS

1x4

UNIT A

UNIT B

UNIT C

UNIT D

UNIT A

UNIT B

UNIT C

UNIT D

MINIMUM

RATED

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35

20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 35 35 35

20 20 20 20 20 26 26 26 26 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 35 35 35 35 35

20 26 35 52 71 26 35 52 71 35 52 52 26 35 52 71 35 52 52 35 52 26 35 52 35 52 35 52 35

2.05 1.98 2.02 1.88 1.65 1.97 2.00 1.79 1.58 1.93 1.67 1.47 1.96 2.01 1.73 1.51 1.86 1.61 1.43 1.73 1.51 2.65 2.45 2.12 2.27 1.99 2.12 1.87 2.65

2.05 1.98 2.02 1.88 1.65 1.97 2.00 1.79 1.58 1.93 1.67 1.47 2.51 2.58 2.22 1.95 2.39 2.07 1.83 2.96 2.60 2.65 2.45 2.12 2.27 1.99 2.83 2.49 2.65

2.05 1.98 2.02 1.88 1.65 2.53 2.57 2.30 2.03 3.32 2.86 3.78 2.51 2.58 2.22 1.95 3.18 2.77 3.67 2.96 2.60 2.65 2.45 2.12 3.03 2.65 2.83 2.49 2.65

2.05 2.55 3.45 4.85 5.65 2.53 3.43 4.61 5.41 3.32 4.30 3.78 2.51 3.44 4.44 5.19 3.18 4.15 3.67 2.96 3.89 2.65 3.26 4.24 3.03 3.98 2.83 3.74 2.65

3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71

8.20 8.50 9.50 10.50 10.60 9.00 10.00 10.50 10.60 10.50 10.50 10.50 9.50 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60

COMBINATIONS UNIT A

1x4

HEATING CAPACITY (KW)

RATED CAPACITY (KW);

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35

UNIT B 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 35 35 35

RATED CAPACITY (KW)

MAXIMUM MINIMUM 10.60 11.66 12.72 13.78 13.78 12.72 13.25 13.78 13.78 13.78 13.78 13.78 13.25 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78

HEATING CAPACITY (KW)

UNIT C

UNIT D

UNIT A

UNIT B

UNIT C

UNIT D

MINIMUM

RATED

20 20 20 20 20 26 26 26 26 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 35 35 35 35 35

20 26 35 52 71 26 35 52 71 35 52 52 26 35 52 71 35 52 52 35 52 26 35 52 35 52 35 52 35

2.50 2.36 2.31 1.99 1.73 2.38 2.22 1.90 1.65 2.04 1.77 1.55 2.29 2.10 1.81 1.59 1.94 1.69 1.49 1.81 1.59 2.78 2.56 2.22 2.38 2.08 2.22 1.96 2.78

2.50 2.36 2.31 1.99 1.73 2.38 2.22 1.90 1.65 2.04 1.77 1.55 2.94 2.70 2.32 2.04 2.50 2.17 1.92 3.10 2.72 2.78 2.56 2.22 2.38 2.08 2.96 2.61 2.78

2.50 2.36 2.31 1.99 1.73 3.07 2.85 2.44 2.13 3.51 3.03 4.00 2.94 2.70 2.32 2.04 3.33 2.90 3.84 3.10 2.72 2.78 2.56 2.22 3.17 2.78 2.96 2.61 2.78

2.50 3.03 3.96 5.12 5.92 3.07 3.81 4.87 5.67 3.51 4.54 4.00 2.94 3.60 4.65 5.44 3.33 4.34 3.84 3.10 4.08 2.78 3.42 4.44 3.17 4.16 2.96 3.92 2.78

3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89

10.00 10.10 10.90 11.10 11.10 10.90 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10

EER SEER (W/W)

POWER POWER (KW)

0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89

MAXIMUM

2.30 2.50 2.88 3.27 3.30 2.73 3.12 3.27 3.30 3.27 3.27 3.27 2.94 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30

3.30 3.47 3.63 4.29 4.29 3.63 3.96 4.29 4.29 4.29 4.29 4.29 3.80 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29

POWER INPUT (KW)

MAXIMUM MINIMUM 11.10 11.66 12.21 13.32 13.32 12.21 12.77 13.32 13.32 13.32 13.32 13.32 12.77 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32

RATED

0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83

RATED

MAXIMUM

2.59 2.69 2.95 3.04 3.04 2.95 3.00 3.06 3.06 3.04 3.06 3.06 3.00 3.05 3.06 3.06 3.05 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06

3.06 3.21 3.36 3.98 3.98 3.36 3.67 3.98 3.98 3.98 3.98 3.98 3.52 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98

ENERGY CLASS

RATED CAPACITY 3.56 3.40 3.30 3.21 3.21 3.30 3.21 3.21 3.21 3.21 3.21 3.21 3.23 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21

COP (W/W)

7.6 7.6 7.6 7.4 7.4 7.6 7.6 7.6 7.6 7.6 7.6 7.4 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.4 7.6 7.6 7.6 7.6 7.6 7.6 7.4 7.6

SCOP

A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++

ENERGY CLASS

COP -7

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

3.20 3.11 3.07 3.02 3.02 3.07 3.07 3.01 3.01 3.02 3.01 3.01 3.07 3.02 3.01 3.01 3.02 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01

RATED CAPACITY 3.86 3.75 3.70 3.65 3.65 3.70 3.70 3.63 3.63 3.65 3.63 3.63 3.70 3.64 3.63 3.63 3.64 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63

3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8

75 75


RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS

COMBINED SYSTEMS KAM5-120 DN7

R-410A MULTISYSTEM

x1

x2

x3

x4

20

20+20

20+20+20

20+20+20+20

20+20+20+20+20

26

20+26

20+20+26

20+20+20+26

20+20+20+20+26

35

20+35

20+20+35

20+20+20+35

20+20+20+20+35

52

20+52

20+20+52

20+20+20+52

20+20+20+20+52

71

20+71

20+20+71

20+20+20+71

20+20+20+20+71

26+26

20+26+26

20+20+26+26

20+20+20+26+26

26+35

20+26+35

20+20+26+35

20+20+20+26+35

26+52

20+26+52

20+20+26+52

20+20+20+26+52

26+71

20+26+71

20+20+26+71

20+20+20+26+71

35+35

20+35+35

20+20+35+35

20+20+20+35+35

35+52

20+35+52

20+20+35+52

20+20+20+35+52

35+71

20+35+71

20+20+35+71

20+20+20+35+71

52+52

20+52+52

20+20+52+52

20+20+20+52+52

52+71

26+26+26

20+20+52+71

20+20+26+26+26

71+71

26+26+35

20+26+26+26

20+20+26+26+35

26+26+52

20+26+26+35

20+20+26+26+52

26+26+71

20+26+26+52

20+20+26+26+71

26+35+35

20+26+26+71

20+20+26+35+35

26+35+52

20+26+35+35

20+20+26+35+52

26+35+71

20+26+35+52

20+20+26+52+52

26+52+52

20+26+35+71

20+20+35+35+35

35+35+35

20+26+52+52

20+20+35+35+52

35+35+52

20+26+52+71

20+26+26+26+26

35+35+71

20+35+35+35

20+26+26+26+35

35+52+52

20+35+35+52

20+26+26+26+52

35+52+71

20+35+52+52

20+26+26+26+71

52+52+52

20+35+52+71

20+26+26+35+35

26+26+26+26

20+26+26+35+52

26+26+26+35

20+26+35+35+35

26+26+26+52

20+26+35+35+52

26+26+26+71

20+35+35+35+35

26+26+35+35

26+26+26+26+26

26+26+35+52

26+26+26+26+35

26+26+35+71

26+26+26+26+52

26+26+52+52

26+26+26+35+35

26+35+35+35

26+26+26+35+52

26+35+35+52

26+26+35+35+35

26+35+35+71

26+35+35+35+35

26+35+52+52 35+35+35+35 35+35+35+52

76 76

x5


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution RATED CAPACITY (kW)

COMBINED SYSTEMS

1x5

HEATING CAPACITY (kW)

UNIT A

UNIT B

UNIT C

UNIT D

UNIT E

UNIT A

UNIT B

UNIT C

UNIT D

UNIT E

MIN.

RAT.

MAX.

MIN.

RAT.

MAX.

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 26 35 26 26 26 26 26 26 35

20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 26 35 35 35 26 26 26 26 26 35 35

20 20 20 20 20 26 26 26 26 35 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 26 35 35 35 35 35 26 26 26 35 35 35 35

20 26 35 52 71 26 35 52 71 35 52 71 52 26 35 52 71 35 52 52 35 52 26 35 52 71 35 52 35 52 35 26 35 52 35 52 35 35

2.10 2.08 2.01 1.87 1.66 2.06 2.00 1.79 1.59 1.91 1.69 1.51 1.51 2.05 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.00 1.87 1.66 1.48 1.76 1.57 1.66 1.48 1.57 2.46 2.31 2.05 2.17 1.94 2.05 1.94

2.10 2.08 2.01 1.87 1.66 2.06 2.00 1.79 1.59 1.91 1.69 1.51 1.51 2.05 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.57 2.41 2.13 1.91 2.26 2.01 2.13 1.91 2.68 2.46 2.31 2.05 2.17 1.94 2.05 2.59

2.10 2.08 2.01 1.87 1.66 2.06 2.00 1.79 1.59 1.91 1.69 1.51 1.51 2.63 2.52 2.21 1.98 2.36 2.09 1.88 2.95 2.64 2.57 2.41 2.13 1.91 2.26 2.01 2.84 2.54 2.68 2.46 2.31 2.05 2.17 1.94 2.73 2.59

2.10 2.08 2.01 1.87 1.66 2.65 2.57 2.31 2.05 3.28 2.89 2.59 3.88 2.63 2.52 2.21 1.98 3.14 2.78 3.75 2.95 2.64 2.57 2.41 2.13 1.91 3.01 2.68 2.84 2.54 2.68 2.46 2.31 2.05 2.89 2.59 2.73 2.59

2.10 2.68 3.45 4.81 5.68 2.65 3.43 4.61 5.47 3.28 4.34 5.18 3.88 2.63 3.35 4.43 5.27 3.14 4.18 3.75 2.95 3.95 2.57 3.21 4.26 5.09 3.01 4.03 2.84 3.82 2.68 2.46 3.08 4.10 2.89 3.88 2.73 2.59

4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18

10.50 11.00 11.50 12.30 12.30 11.50 12.00 12.30 12.30 12.30 12.30 12.30 12.30 12.00 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30

14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00

1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01

3.09 3.24 3.42 3.73 3.76 3.42 3.57 3.73 3.76 3.69 3.75 3.80 3.80 3.57 3.69 3.75 3.80 3.73 3.76 3.84 3.73 3.76 3.69 3.73 3.76 3.80 3.73 3.76 3.75 3.80 3.75 3.73 3.73 3.76 3.75 3.80 3.75 3.76

4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55

RATED CAPACITY (kW)

COMBINED SYSTEMS

HEATING CAPACITY (kW)

UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E

1x5

POWER INPUT (kW)

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 26 35 26 26 26 26 26 26 35

20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 26 35 35 35 26 26 26 26 26 35 35

20 20 20 20 20 26 26 26 26 35 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 26 35 35 35 35 35 26 26 26 35 35 35 35

20 26 35 52 71 26 35 52 71 35 52 71 52 26 35 52 71 35 52 52 35 52 26 35 52 71 35 52 35 52 35 26 35 52 35 52 35 35

2.46 2.33 2.15 1.87 1.66 2.21 2.05 1.79 1.59 1.91 1.69 1.51 1.51 2.10 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.00 1.87 1.66 1.48 1.76 1.57 1.66 1.48 1.57 2.46 2.31 2.05 2.17 1.94 2.05 1.94

2.46 2.33 2.15 1.87 1.66 2.21 2.05 1.79 1.59 1.91 1.69 1.51 1.51 2.10 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.57 2.41 2.13 1.91 2.26 2.01 2.13 1.91 2.68 2.46 2.31 2.05 2.17 1.94 2.05 2.59

2.46 2.33 2.15 1.87 1.66 2.21 2.05 1.79 1.59 1.91 1.69 1.51 1.51 2.70 2.52 2.21 1.98 2.36 2.09 1.88 2.95 2.64 2.57 2.41 2.13 1.91 2.26 2.01 2.84 2.54 2.68 2.46 2.31 2.05 2.17 1.94 2.73 2.59

2.46 2.33 2.15 1.87 1.66 2.84 2.64 2.31 2.05 3.28 2.89 2.59 3.88 2.70 2.52 2.21 1.98 3.14 2.78 3.75 2.95 2.64 2.57 2.41 2.13 1.91 3.01 2.68 2.84 2.54 2.68 2.46 2.31 2.05 2.89 2.59 2.73 2.59

2.46 2.99 3.69 4.81 5.68 2.84 3.51 4.61 5.47 3.28 4.34 5.18 3.88 2.70 3.35 4.43 5.27 3.14 4.18 3.75 2.95 3.95 2.57 3.21 4.26 5.09 3.01 4.03 2.84 3.82 2.68 2.46 3.08 4.10 2.89 3.88 2.73 2.59

POWER INPUT (kW)

MIN.

RAT.

MAX.

MIN.

RAT.

MAX.

4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18

12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30

14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94

0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91

3.40 3.40 3.40 3.37 3.28 3.40 3.40 3.32 3.28 3.40 3.32 3.28 3.28 3.40 3.40 3.32 3.28 3.37 3.37 3.28 3.37 3.28 3.40 3.37 3.28 3.28 3.37 3.28 3.32 3.28 3.32 3.37 3.37 3.28 3.32 3.28 3.32 3.28

4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21

EER SEER (W/W) (W/W)

ENERGY CLASS

RATED CAPACITY 3.40 7.7 3.40 7.7 3.37 7.7 3.30 7.7 3.27 7.7 3.37 7.7 3.37 7.7 3.30 7.7 3.27 7.7 3.33 7.7 3.28 7.7 3.23 7.7 3.23 7.7 3.37 7.7 3.33 7.7 3.28 7.7 3.23 7.7 3.30 7.7 3.27 7.7 3.20 7.7 3.30 7.7 3.27 7.7 3.33 7.7 3.30 7.7 3.27 7.7 3.23 7.7 3.30 7.7 3.27 7.7 3.28 7.7 3.23 7.7 3.28 7.7 3.30 7.7 3.30 7.7 3.27 7.7 3.28 7.7 3.23 7.7 3.28 7.7 3.27 7.7

A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++

COP SCOP (W/W)

ENERGY CLASS

COP -7

RATED CAPACITY 3.62 3.7 3.62 3.8 3.62 3.8 3.65 3.8 3.75 3.6 3.62 3.8 3.62 3.8 3.71 3.8 3.75 3.8 3.62 3.8 3.71 3.6 3.75 3.5 3.75 3.5 3.62 3.8 3.62 3.8 3.71 3.8 3.75 3.5 3.65 3.6 3.65 3.6 3.75 3.4 3.65 3.6 3.75 3.6 3.62 3.8 3.65 3.8 3.75 3.8 3.75 3.5 3.65 3.8 3.75 3.6 3.71 3.6 3.75 3.4 3.71 3.6 3.65 3.8 3.65 3.8 3.75 3.5 3.71 3.6 3.75 3.5 3.71 3.6 3.75 3.5

A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A

2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94

77 77


RESIDENTIAL PRODUCT RANGE R-32 COMBINED UNITS

COMBINED SYSTEMS KAM2-52 DR7

R-32 MULTISYSTEM

x1

x2

26

26+26

35

26+35

52

26+52 35+35

KAM3-78 DR7

78 78

x1

x2

x3

26

26+26

26+26+26

35

26+35

26+26+35

52

26+52

26+26+52

35+35

26+35+35

35+52

26+35+52

52+52

35+35+35


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

RATED CAPACITY (kW)

COMBINED SYSTEMS

1x2

UNIT A

UNIT B

UNIT A

26

26

2.64

26

35

2.27

UNIT B

MINIMUM

RATED

ENERGY CLASS

SEER

MINIMUM

RATED

MAXIMUM RATED CAPACITY

2.64

2.11

5.28

6.44

0.54

1.63

2.04

3.23

6.6

A++

3.03

2.11

5.3

6.44

0.54

1.64

2.04

3.23

6.6

A++

52

1.8

3.6

2.11

5.4

6.49

0.54

1.65

2.04

3.27

6.6

A++

35

2.65

2.65

2.11

5.3

6.44

0.54

1.64

2.04

3.23

6.6

A++

RATED CAPACITY (kW)

UNIT A

UNIT B

UNIT A

UNIT B

26

26

2.79

26

35

2.4

26

52

1.93

35

35

2.8

HEATING POWER (kW)

POWER INPUT (kW) MAXIMUM MINIMUM

RATED CAPACITY

2.23

5.57

6.8

0.47

1.39

1.88

4.0

4.0

A+

3.2

2.23

5.6

6.8

0.47

1.4

1.88

4.0

4.0

A+

3.2

3.87

2.23

5.8

6.85

0.47

1.46

1.88

3.97

4.0

A+

3.17

2.8

2.23

5.6

6.8

0.47

1.4

1.88

4.0

4.0

A+

3.2

HEATING CAPACITY (kW)

UNIT B

UNIT C

MINIMUM

RATED

26

26

26

2.63

2.63

2.63

2.77

7.9

8.69

26

26

35

2.37

2.37

3.16

2.77

7.9

8.69

26

26

52

1.98

1.98

3.95

2.77

7.9

26

35

35

2.15

2.87

2.87

2.77

26

35

52

1.82

2.43

3.65

35

35

35

2.63

2.63

2.63

RATED CAPACITY (kW) UNIT B

UNIT C

MINIMUM

MAXIMUM

POWER INPUT (kW)

UNIT A

UNIT A

COP -7

3.2

UNIT C

UNIT C

ENERGY CLASS

2.79

UNIT B

UNIT B

RATED

SCOP

RATED

UNIT A

UNIT A

COP (W/W)

MINIMUM

RATED CAPACITY (kW)

COMBINED SYSTEMS

1x3

MAXIMUM

EER (W/W)

35

COMBINED SYSTEMS

1x3

POWER INPUT (kW)

26

COMBINED SYSTEMS

1x2

HEATING CAPACITY (kW)

MAXIMUM MINIMUM

EER (W/W)

SEER

ENERGY CLASS

RATED

MAXIMUM

0.74

2.39

2.9

3.3

6.7

A++

0.74

2.39

2.9

3.31

6.7

A++

8.69

0.74

2.39

2.9

3.31

6.7

A++

7.9

8.69

0.74

2.38

2.9

3.32

6.7

A++

2.77

7.9

8.69

0.74

2.38

2.9

3.32

6.7

A++

2.77

7.9

8.69

0.74

2.38

2.9

3.32

6.7

A++

SCOP

ENERGY CLASS

HEATING POWER (kW)

POWER INPUT (kW)

RATED

RATED

MAXIMUM MINIMUM

COP (W/W) MAXIMUM

RATED CAPACITY

COP -7

RATED CAPACITY

26

26

26

2.73

2.73

2.73

2.87

8.2

9.02

0.68

2.20

2.62

3.73

4.0

A+

3.13

26

26

35

2.49

2.49

3.32

2.87

8.3

9.02

0.68

2.22

2.62

3.74

4.0

A+

3.14

26

26

52

2.08

2.08

4.15

2.87

8.3

9.02

0.68

2.22

2.62

3.74

4.0

A+

3.14

26

35

35

2.26

3.02

3.02

2.87

8.3

9.02

0.68

2.21

2.62

3.76

4.0

A+

3.16

26

35

52

1.92

2.56

3.83

2.87

8.3

9.02

0.68

2.22

2.62

3.74

4.0

A+

3.14

35

35

35

2.77

2.77

2.77

2.87

8.3

9.02

0.68

2.21

2.62

3.76

4.0

A+

3.16

79 79


RESIDENTIAL PRODUCT RANGE R-32 COMBINED UNITS

COMBINED SYSTEMS KAM4-105 DR7

R-32 MULTISYSTEM

x1

x2

x3

x4

26

26+26

26+26+26

26+26+26+26

35

26+35

26+26+35

26+26+26+35

52

26+52

26+26+52

26+26+26+52

70

26+70

26+26+70

26+26+35+35

35+35

26+35+35

26+26+35+52

35+52

26+35+52

26+35+35+35

35+70

26+35+70

26+35+35+52

52+52

26+52+52

35+35+35+35

35+35+35

35+35+35+52

35+35+52 35+35+70 35+52+52

KAM5-120 DR7

x1

x2

x3

x4

x5

26

26+26

26+26+26

26+26+26+26

26+26+26+26+26

35

26+35

26+26+35

26+26+26+35

26+26+26+26+35

52

26+52

26+26+52

26+26+26+52

26+26+26+26+52

71

26+71

26+26+71

26+26+26+71

26+26+26+35+35

35+35

26+35+35

26+26+35+35

26+26+26+35+52

35+52

26+35+52

26+26+35+52

26+26+35+35+35

35+71

26+35+71

26+26+35+71

26+35+35+35+35

52+52

26+52+52

26+35+35+35

26+35+35+35+52

35+35+35

26+35+35+52

35+35+35+35+35

35+35+52

35+35+35+35

35+35+71

35+35+35+52

35+52+52

80 80


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

RATED CAPACITY (KW)

COMBINED SYSTEMS

1x4

UNIT A

UNIT B

UNIT C

UNIT

UNIT A

26

26

26

26

2.63

26

26

26

35

2.42

26

26

26

52

2.1

26

26

35

35

26

26

35

26

35

35

26

35

35

35

35

35

35

UNIT D

MIN.

RATED

MAX.

MIN.

RATED

MAX.

2.63

2.63

2.63

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

2.42

2.42

3.23

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

2.1

2.1

4.2

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

2.25

2.25

3

3

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

52

1.97

1.97

2.63

3.94

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

35

2.1

2.8

2.8

2.8

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

52

1.85

2.47

2.47

3.71

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

35

35

2.63

2.63

2.63

2.63

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

35

52

2.33

2.33

2.33

3.5

3.68

10.5

13.65

0.95

3.5

4.27

3.0

6.5

A++

ENERGY CLASS

COP -7

RATED CAPACITY (KW)

UNIT A

UNIT B

UNIT C

UNIT

UNIT A

UNIT B

UNIT C

26

26

26

26

2.78

2.78

26

26

26

35

2.56

2.56

26

26

26

52

2.22

2.22

2.22

26

26

35

35

2.38

2.38

26

26

35

52

2.08

2.08

26

35

35

35

2.22

2.96

26

35

35

52

1.96

35

35

35

35

35

35

35

52

MIN.

RATED

MAX.

MIN.

RATED

MAX.

2.78

2.78

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

2.56

3.42

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

4.44

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

3.17

3.17

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

2.78

4.16

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

2.96

2.96

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

2.61

2.61

3.92

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

2.78

2.78

2.78

2.78

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

2.47

2.47

2.47

3.70

3.89

11.1

13.32

0.79

2.91

3.79

3.81

4.0

A

3.11

RATED CAPACITY (kW)

HEATING CAPACITY (kW)

RATED CAPACITY

EER SEER (W/W) (W/W)

POWER INPUT (kW)

ENERGY CLASS

UNIT E

MIN.

RAT.

MAX.

MIN.

RAT.

MAX.

RATED CAPACITY

2.46

2.46

4.18

12.3

14

1.11

4.1

4.55

3.0

6.8

A++

2.31

3.08

4.18

12.3

14

1.11

4.1

4.55

3.0

6.8

A++

2.05

2.05

4.1

4.18

12.3

14

1.11

4.09

4.55

3.01

6.8

A++

2.17

2.17

2.89

2.89

4.18

12.3

14

1.11

4.07

4.55

3.02

6.8

A++

1.94

1.94

1.94

2.59

3.88

4.18

12.3

14

1.11

4.09

4.55

3.01

6.8

A++

35

2.05

2.05

2.73

2.73

2.73

4.18

12.3

14

1.11

4.07

4.55

3.02

6.8

A++

35

35

1.94

2.59

2.59

2.59

2.59

4.18

12.3

14

1.11

4.09

4.55

3.01

6.8

A++

35

35

52

1.76

2.34

2.34

2.34

3.51

4.182

12.3

14

1.11

4.09

4.55

3.00

6.8

A++

35

35

35

2.46

2.46

2.46

2.46

2.46

4.182

12.3

14

1.11

4.09

4.55

3.00

6.8

A++

UNIT A

UNIT B

UNIT C

UNIT D

UNIT E

UNIT A

UNIT B

UNIT C

UNIT D

26

26

26

26

26

2.46

2.46

2.46

26

26

26

26

35

2.31

2.31

2.31

26

26

26

26

52

2.05

2.05

26

26

26

35

35

2.17

26

26

26

35

52

26

26

35

35

26

35

35

26

35

35

35

RATED CAPACITY (kW)

COMBINED SYSTEMS

HEATING CAPACITY (kW)

UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E

1x5

COP W/W SCOP

POWER INPUT (kW)

HEATING CAPACITY (KW)

RATED CAPACITY

UNIT D

COMBINED SYSTEMS

1x5

ENERGY CLASS

SEER

UNIT C

COMBINED SYSTEMS

1x4

UNIT B

EER W/W

POWER INPUT (kW)

COOLING CAPACITY (KW)

COP SCOP (W/W)

POWER INPUT (kW)

MIN.

RAT.

MAX.

MIN.

RAT.

MAX.

ENERGY CLASS

COP -7

RATED CAPACITY

26

26

26

26

26

2.46

2.46

2.46

2.46

2.46

4.18

12.3

14.94

0.9

3.32

4.14

3.71

4.0

A

3.01

26

26

26

26

35

2.31

2.31

2.31

2.31

3.08

4.18

12.3

14.94

0.9

3.32

4.14

3.71

4.0

A

3.01

26

26

26

26

52

2.05

2.05

2.05

2.05

4.1

4.18

12.3

14.94

0.9

3.23

4.14

3.81

3.5

A

3.11

26

26

26

35

35

2.17

2.17

2.17

2.89

2.89

4.18

12.3

14.94

0.9

3.26

4.14

3.77

3.8

A

3.07

26

26

26

35

52

1.94

1.94

1.94

2.59

3.88

4.18

12.3

14.94

0.9

3.23

4.14

3.81

3.5

A

3.11

26

26

35

35

35

2.05

2.05

2.73

2.73

2.73

4.18

12.3

14.94

0.9

3.3

4.14

3.77

3.8

A

3.07

26

35

35

35

35

1.94

2.59

2.59

2.59

2.59

4.18

12.3

14.94

0.9

3.2

4.14

3.81

3.5

A

3.11

26

35

35

35

52

1.84

1.84

2.46

2.46

3.69

4.182

12.3

14.94

0.9

3.2

4.14

3.81

3.8

A

3.11

35

35

35

35

35

2.46

2.46

2.46

2.46

2.46

4.182

12.3

14.94

0.9

3.2

4.14

3.81

3.5

A

3.11

81 81


RESIDENTIAL PRODUCT RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

VILLA BAHIA PRINCIPE RESIDENTIAL Location: Dominican Republic Units installed: Multisystem Suite Capacity: 34 kW

THE SUITE RESIDENTIAL RANGE IS PRESENT IN THE MOST COMMON PLACES. FROM APARTMENTS TO HOSPITALS, SCHOOLS AND UNIVERSITIES, THE COMFORT AND TECHNOLOGY OF THIS RANGE PROVIDES THE WELL-BEING THAT ALL HOMES NEED.

OTHER CUSTOMERS THAT TRUSTED KAYSUN SUITE HOTELS Vera Apart-Hotel (Almeria) Sangulí Resort Salou (Tarragona)

SCHOOLS AND UNIVERSITIES University of Salamanca (Salamanca), The Capuchins School (Murcia), María Maroto School (Murcia), Autism Association of Jerez (Cádiz)

LEISURE CENTRES Vals Sport - Sports Centre (Malaga) HOSPITAL, CLINICS AND HEALTH CENTRES Jesus Nazareno Hospital (Córdoba), Santomera Health Centre (Murcia) BUSINESS CENTRES AND OFFICES ISOLAIS Office (Seville)

82 82

RESIDENCES 51 residences in Carrión (Seville), 52 residences in Torreblanca (Seville), La Pineda Apartments (Tarragona), Puerto Mahón Apartments (Majorca), Jardines de Santa Ana Residence (Seville)


SUITE RESIDENTIAL

Inspiration, Innovation, Evolution

SANGULĂ? SALOU CAMPING RESORT

Location: Cambrils (Tarragona) Units installed: Suite 1X1

ESCUELA MARIA MAROTO SCHOOLS

Location: Murcia Units installed: Multisystem Suite

83 83


AQUATIX DOMESTIC HOT WATER RANGE

INTRODUCTION TO THE PRODUCT RANGE.......................................86

UNITS Aquantia.................................................Monobloc...........................94 Aquantia.................................................Bibloc.................................98 Domestic hot water tanks.....................BS, G..................................102 Compak..................................................KHP ACS...........................106 KEY INSTALLATIONS..........................................................................108


AQUATIX DOMESTIC HOT WATER

AQUATIX

DOMESTIC HOT WATER RANGE


DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

AQUATIX

DOMESTIC HOT WATER RANGE

The Aquatix range reveals the vital energy of water and how to make the most of the resources in a single space. Using a heat pump system, hot water with temperatures of up to 70ºCcan be produced, putting the best qualities of this natural resource to work to heat the home with domestic hot water and underfloor heating. The Aquatix heat pump is an alternative to the traditional hot water boiler, and saves a significant amount of energy, offering a broad variety of advantages for the home with with maximum energy efficiency.

“THE MOST ECOLOGICAL INNOVATION FOR YOUR HOME”

Aquatix equipment is designed for spaces located in the home, allowing for fast and simple installation. We often seek an alternative system to provide comfort, and the search needs not go further than the Aquatix range, with the most advanced technology and maximum savings.

AQUANTIA Discover Aquantia, the integrated system that provides heating, climate control and domestic hot water to your home. Enjoy maximum comfort all year round, with the great energy efficiency that characterises this system based on heat pumps. The reversible heat pump is a system that obtains renewable energy from outside to heat or cool your home. It is the most efficient technology, absorbing more energy from the exterior than what Aquantia consumes. As well as being more environmentally-friendly and energy efficient than other systems such as boilers, Aquantia can replace all of these systems and work together with them.

+ + + +

86

IT OFFERS HEATING, CLIMATE CONTROL AND DOMESTIC HOT WATER: A YEAR-ROUND SOLUTION

ENERGY EFFICIENT (ENVIRONMENT, ECONOMIC)

WIDE RANGE OF OPERATING TEMPERATURES

CAN FUNCTION WITH OTHER SOURCES OF ENERGY, SUCH AS SOLAR ENERGY AND BOILERS


Radiators

Heating: • • • •

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

Underfloor heating Radiators Fan Coils Combination of the above

Climate control: • • •

Fan Coils Underfloor cooling Combination of the above

DOMESTIC HOT WATER: •

Accumulation tanks

Water tank Heating water Hot Water

Underfloor heating Aquantia

Aquantia supplies hot and cold water to its underfloor heating, radiators, fan coils and water tanks. In addition to being a totally independent source of energy, it can also work with external sources (solar energy, boilers, etc.).

THERE ARE TWO INSTALLATION OPTIONS, DEPENDING ON YOUR REQUIREMENTS:

MONOBLOC

BIBLOC POMPE À CHALEUR

All components in the compact outdoor unit.

A hydraulic system in an indoor unit and a heat pump in an outdoor unit.

87


DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

AQUANTIA CONTROL •

Touch control

A choice of operating modes

Priority manager

Temperature setpoints

Daily and weekly scheduling

Option to enquire about working parameters, error codes, service calls

Different levels of user

Test Run

Follow Me function (temperature sensor built into the control)

Modbus communication

KCTAQ-01 SOME FUNCTIONS •

Silence mode: Minimum noise levels guaranteed

Forced domestic hot water mode

Disinfection mode: Raises temperature to 70ºC

Air purging

Pre-heating of the environment

Dehumidify the ground

Choose from various operating modes (eco mode, holiday mode) and priorities

Domestic hot water tank

Thermostat 2

Touch control

T Indoor unit

Radiator Zone 2

Zone 2 controlled by thermostat 2

Zone 1

Zone 1 controlled by thermostat 1

M

Outdoor unit

M

3-way valve

2-way valve

T Thermostat 1

88

Underfloor heating


Inspiration, Innovation, Evolution

AQUATIX DOMESTIC HOT WATER

Heat capacity of up to 80% at -7ºC, thanks to the size of the exchanger and compressor

Heat exchanger 9.5 pipe with internal groove optimises the efficiency of the heat exchange. The flaps increase the heat exchange area and reduce air resistance. The blue coat increases resistance against corrosive agents and increases durability.

Hydronic module Hydronic module with integrated DC water pump (monobloc) or separate DC water pump (bibloc)

Ventilator with brushless DC motor DC motors with stage-free controls reduce noise and consumption of the system

Compressor with DC inverter Support resistance

The novel double rotary compressor with DC inverter produces less noise, greater operating frequency and more accurate control. The feeder system and this greater frequency reduce consumption by more than 30%.

It has support electric resistance for extreme outdoor temperatures

Highly efficient DC motor Simple rotary

- Redesigned core motor

Double rotary

- High-density neodymium magnet - Concentrated stator - Wide range of operating temperatures Minimal vibration - Twin eccentric cams - 2 balance weights Highly stable moving parts - Perfect fit of motor components - Optimised compressor action - Very robust ball bearings

Double rotary compressor

- Compact structure

EASY INSTALLATION, MINIMAL MAINTENANCE •

Compact structure. The hydronic part can be installed indoors or outdoors.

Easily connected to the pipe system of the house.

Rapid access to the components of the system for inspection and maintenance

SMART, ADAPTABLE SYSTEM •

Select a work curve. Depending on the desired temperature, the system will automatically adapt when the temperature outside changes.

WIDE RANGE OF OPERATING TEMPERATURES

60°C

DOMESTIC HOT WATER

50°C 40°C

Heating

43°C

70°C Cold

46°C

60°C

Heating 60°C

60°C

50°C

35°C

30°C

40°C

20°C

40°C

30°C

10°C 20°C

0°C -5°C

-10°C -20°C

DOMESTIC HOT WATER

-20°C

-20°C

Outdoor ambient temperature

Cold 25°C

25°C

10°C 5°C

5°C

Output water temperature

89


DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

ENVIRONMENTALLY DC INVERTER The traditional motors used in heat pumping systems waste energy, as they always work at full load. The technology used in the KAYSUN DC Inverter reduces energy consumption by up to 30%, since it adapts energy consumption to the actual load of the system.

WATER AT CONSTANT TEMPERATURE The rotation speed of the compressor is controlled with great precision and according to demand using DC Inverter technology. The temperature setpoint for the water remains stable, providing the user with greater comfort.

FEWER STOPS AND STARTS The technology of the inverter reduces the frequency of stop-start cycles. This extends the life of components and minimises noise.

QUIET Most of the time it is in operation, the energy requirements of the home are less than full capacity. As well as a Silence mode, due to the adjustable frequency of the compressor the equipment for the most part operates at less than full capacity, reducing noise levels.

BOTH PIECES OF EQUIPMENT (MONOBLOC AND BIBLOC) HAVE AN ERP ENERGY EFFICIENCY RATING OF A++

90


AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

POWER RANGE

AQUANTIA MONOBLOC Heating capacity (kW)

4

(Page 94)

5

6

7

8

12

14

16

SINGLE-PHASE KHP-MO 5 DVN

KHP-MO 7 DVN

KHP-MO 12 DVN KHP-MO 14 DVN KHP-MO 16 DVN

TRI-PHASE KHP-MO 12 DTN KHP-MO 14 DTN KHP-MO 16 DTN

AQUANTIA BIBLOC Heating capacity (kW)

(Page 98) POMPE À CHALEUR

4

5

6

7

8

12

14

16

KHP-BI 8 DVN

KHP-BI 12 DVN

KHP-BI 14 DVN

KHP-BI 16 DVN

KHP-BI 12 DTN

KHP-BI 14 DTN

KHP-BI 16 DTN

SINGLE-PHASE KHP-BI 4 DVN

KHP-BI 6 DVN

TRI-PHASE

91


DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

COMPAK

POMPE ร CHALEUR

COMPAK KHP This compact unit, fitted with evaporator, condenser and built-in tank, is an optional solution to be considered for producing domestic hot water or underfloor heating. This option is easy to integrate into many spaces because it eliminates the need for many units, as everything is built into the same unit. These unit's condenser is built around the water tank, keeping the refrigerant and domestic hot water from coming into direct contact.

LITRES

150

200

250

300

COMPAK KHP 15 190 ACS1

350

COMPAK KHP 35 300 ACS1

Liquid deposit Ventilator/evaporator

Compressor

Thermostatic Expansion Valve AIR INLET

AIR INLET

Water tank

COMPAK KHP 15 190 ACS1

(Page 106)

The KAYSUN COMPAK KHP 15 190 ACS1 is an ideal option for domestic use. With a storage capacity of 190 litres and a power input of 500W, it is an interesting option for producing domestic hot water.

Water Magnesium anode

Condenser Resistances

COMPAK KHP 35 300 ACS1

(Page 106)

The new 3 kW COMPAK KHP unit with vitrified enamel, which allows water to be discharged at temperatures close to 70ยบC. This compact unit, equipped with a centrifugal fan and a static pressure of 25 Pa,allows to direct the air through a duct of up to 10 metres in length.

COMPAK KHP 35 300 ACS1

92


AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

UNITS TECHNICAL SPECIFICATIONS

93


DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM

AQUANTIA MONOBLOC TECHNICAL SPECIFICATIONS MODEL

KHP-MO 5 DVN

Power Supply

V/ph/Hz kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W

Heating capacity1 Heating input power1 COP1 Heating capacity2 Heating input power2 COP2 Cooling capacity3 Cooling input power3 EER3 Cooling capacity4 Cooling input power4 EER4 SCOP (Average Zone) SCOP (Warm Zone)

Water 35ºC - Clas. Power Water 55ºC - Clas. Power Water 35ºC Water 55ºC

Compressor type Number of outdoor ventilators Outdoor airflow Exchanger type (water)

1 m3/h

Refrigerant oil type Refrigerant volume Volume of expansion tank Regulation Standard support heater Optional support heater

Output water temperature

mca kPa

6 58.4

Kg L

2.4 2

kW kW dB (A) dB (A) mm Kg mm (inch) Mpa L ºC ºC ºC ºC ºC ºC

3 45.4 46.8 945/1210/402 99 Ø25(1") 0.3 2

3100 6 58.4 2.4 2 Electric expansion valve

Heating7 Cooling8

Heat Cold DOMESTIC HOT WATER Heat Cold DOMESTIC HOT WATER

Rated capacities based on the following conditions: 1. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC. 2. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC. 3. Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC. 4. Air in condenser at 35ºC, water in input/output evaporator 12/7ºC. 5. Seasonal efficiency in Average Climate Zone. 6. Seasonal efficiency in Warm Climate Zone. 7. At 1 m distance, the compressor works with fixed frequency in nominal working condition 1. 8. At 1 m distance, the compressor works with fixed frequency in nominal working condition 3.

94

3100

R-410A

Height / Width / Depth Weight Water pipe connections Safety valve Total water volume Outdoor ambient temperature

1 Plates

Water pump pressure

Sound pressure

KHP-MO 7 DVN

220-240/1/50 220-240/1/50 4.58 6.55 3940 5630 0.97 1.45 4.72 4.52 4.67 6.69 4020 5750 1.43 2.05 3.27 3.26 4.55 6.45 3910 5550 1 1.47 4.55 4.4 4.55 6.71 3910 5770 1.55 2.57 2.94 2.61 4.47-A++ 4.53-A++ 3.29-A++ 3.29-A++ 5.8 6.28 3.71 4.27 Double Rotary DC Inverter

3 50.5 48.5 945/1210/402 99 Ø25(1") 0.3 2 -20~35 -5~46 -20~43 25~60 5~25 40~60


R-410A

KHP-MO 12 DVN 220-240/1/50 12.17 10460 2.73 4.46 12.58 10820 3.86 3.26 12.19 10480 2.65 4.60 12.21 10500 4.17 2.93 4.21-A++ 3.25-A++ 6.36 4.05

KHP-MO 12 TVN

KHP-MO 14 DVN

380-415/3/50 220-240/1/50 12.37 14.76 10640 12690 2.76 3.4 4.48 4.34 12.02 14.08 10340 12110 3.72 4.47 3.23 3.15 12.64 14.61 10870 12560 2.75 3.32 4.6 4.4 12.58 12.95 10820 11130 4.32 4.53 2.91 2.86 4.45-A++ 4.39-A++ 3.25-A++ 3.25-A++ 6.32 6.01 3.8 4.09 Double Rotary DC Inverter

2

2

6250

6250

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

ACS

KHP-MO 14 DTN 380-415/3/50 14.1 12120 3.26 4.33 14.11 12130 4.46 3.16 14.03 12060 3.26 4.3 13.8 11870 5.14 2.68 4.27-A++ 3.27-A++ 4.77 3.75

2

2

6250

6250

7.5 73.55

7.5 73.55

3.6 5

3.6 5

Plates 7.5 73.55

7.5 73.55

3.6 5

3.6 5

R-410A

3 50.7 52.3 1414/1404/405 162 Ø32(1 1/4") 0.3 5.5

Electric expansion valve 4.5 3 55.1 57.1 55.4 57.9 1414/1404/405 1414/1404/405 177 162 Ø32(1 1/4") Ø32(1 1/4") 0.3 0.3 5.5 5.5 -20~35 -5~46 -20~43 25~60 5~25 40~60

4.5 58.7 57.9 1414/1404/405 177 Ø32(1 1/4") 0.3 5.5

95


DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM

AQUANTIA MONOBLOC TECHNICAL SPECIFICATIONS MODEL

KHP-MO 16 DVN

Power

V/ph/Hz kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W

Heating capacity1 Heating input power1 COP1 Heating capacity2 Heating input power2 COP2 Cooling capacity3 Cooling input power3 EER3 Cooling capacity4 Cooling input power4 EER4 SCOP (Average Zone) SCOP (Warm Zone)

Water 35ºC - Clas. Power Water 55ºC - Clas. Power Water 35ºC Water 55ºC

Compressor type Number of outdoor ventilators Outdoor airflow Exchanger type (water)

2 m3/h mca kPa

Refrigerant oil type Refrigerant volume Volume of expansion tank Regulation Standard support heater Optional support heater

Output water temperature

Heating7 Cooling8

Heat Cold DOMESTIC HOT WATER Heat Cold DOMESTIC HOT WATER

kW kW dB (A) dB (A) mm Kg mm (inch) Mpa L ºC ºC ºC ºC ºC ºC

Rated capacities based on the following conditions: 1. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC. 2. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC. 3. Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC. 4. Air in condenser at 35ºC, water in input/output evaporator 12/7ºC. 5. Seasonal efficiency in Average Climate Zone. 6. Seasonal efficiency in Warm Climate Zone. 7. At 1 m distance, the compressor works with fixed frequency in nominal working condition 1. 8. At 1 m distance, the compressor works with fixed frequency in nominal working condition 3.

96

6250

6250

7.5 73.55

7.5 73.55 R-410A

Kg L

Height / Width / Depth Weight Water pipe connections Safety valve Total water volume Outdoor ambient temperature

2 Plates

Water pump pressure

Sound pressure

KHP-MO 16 DTN

220-240/1/50 380-415/3/50 16.33 16.3 14040 14020 3.9 3.88 4.19 4.2 16.12 16.06 13860 13810 5.22 5.23 3.09 3.07 14.82 15.1 12740 12980 3.66 3.78 4.05 4 13.72 15.26 11800 13120 5.16 6.41 2.66 2.38 4.26-A++ 4.17-A++ 3.2-A++ 3.22-A++ 5.54 5.38 3.95 4.31 Double Rotary DC Inverter

3.6 5

3.6 5

Electric expansion valve 3 4.5 59.2 59.0 57.6 57.8 1414/1404/405 1414/1404/405 162 177 Ø32(1 1/4") Ø32(1 1/4") 0.3 0.3 5.5 5.5 -20~35 -5~46 -20~43 25~60 5~25 40~60


R-410A

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

ACS

GENERAL CHARACTERISTICS

An integrated system that provides heating, climate control and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed. • DC ventilator and compressor. • Climate control and domestic hot water from a single piece of equipment. • It can operate on its own or draw on other energy sources already installed. • All components in a compact outdoor unit.

HEATING

+ + + +

UNDERFLOOR HEATING

RADIATORS

FANCOILS

COMBINATION OF THE ABOVE

CLIMATE CONTROL AQUANTIA SINGLE BLOC

+ + +

FANCOILS

COLD FLOOR

COMBINATION OF THE ABOVE

DOMESTIC HOT WATER

+

ACCUMULATION DEPOSITS

TOUCH CONTROL SMART, ADAPTABLE SYSTEM EASY INSTALLATION, MINIMAL MAINTENANCE WIDE RANGE OF OPERATING TEMPERATURES

ACCESSORY* KIT R 8 VN optional support heater kit *For KHP-MO 5 DVN and KHP-MO 7 DVN

97


DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM

AQUANTIA BIBLOC OUTDOOR UNIT

POMPE À CHALEUR

TECHNICAL SPECIFICATIONS MODEL Power

Heating input power1 COP1

Heating input power2 COP2

Cooling input power3 EER3 Cooling capacity4 Cooling input power4 EER4

8

kCal/h

3530

5250

6880

kW

0.82

1.29

1.73 4.62

5

4.73

kW

4.01

5.96

7.34

kCal/h

3450

5130

6310

kW

1.13

1.68

2.13

W/W

3.55

3.55

3.45

4.1

6.2

8

kCal/h

3530

5330

6880

kW

0.84

1.43

1.93

W/W

4.88

4.34

4.15

kW

4.12

6.15

6.44

kCal/h

5540

3540

5290

kW

1.3

2.08

2.24

W/W

3.17

2.96

2.88

Water 35ºC - Clas. Power

4.62-A++

4.68-A++

4.33-A++

3.25-A+

3.3-A+

3.2-A++

Water 35ºC

5.4

5.6

5.76

Water 55ºC

3.74

3.48

3.84

Double Rotary DC Inverter m3/h

1

1

3180

5116

2.5

2.5

2.8

Electric expansion valve Heating7

dB (A)

45.4

50.5

48.4

Cooling8

dB (A)

46.8

48.5

49.2

H

mm

960

960

900

Width

mm

860

860

1327

Depth

mm

380

380

400

Kg

60

60

76

mm (inch)

Ø9.5 (3/8”)

mm (inch)

Ø15.9(5/8”)

m

2/20

2/20

2/30

m

10

20

30

m

8

15

25

Heat

ºC

Cold

ºC

-5~46

DOMESTIC HOT WATER

ºC

-20~43

Recommended indoor unit

Rated capacities based on the following conditions: 1. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC. 2. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC. 3. Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC. 4. Air in condenser at 35ºC, water in input/output evaporator 12/7ºC. 5. Seasonal efficiency in Average Climate Zone. 6. Seasonal efficiency in Warm Climate Zone. 7. At 1 m distance, the compressor works with fixed frequency in nominal working condition 1. 8. At 1 m distance, the compressor works with fixed frequency in nominal working condition 3.

98

1 3180

R-410A Kg

Weight Liquid side connections Gas side connections Total length (min.(max.) Outdoor unit pipe height (at the top) Outdoor unit pipe height (at the bottom) Outdoor ambient temperature

6.1

Water 55ºC - Clas. Power

Compressor type Number of outdoor ventilators Outdoor airflow Refrigerant oil type Refrigerant volume Regulation

Dimension

220-240/1/50

4.1

kW

Cooling capacity3

Sound pressure

KHP-BI 8 DVN

220-240/1/50

W/W

Heating capacity2

SCOP6 (Warm Zone)

KHP-BI 6 DVN

220-240/1/50

kW

Heating capacity1

SCOP5 (Average Zone)

KHP-BI 4 DVN V/ph/Hz

-20~35

KIT KHP BI 8 VN

KIT KHP BI 8 VN

KIT KHP BI 8 VN


R-410A

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

ACS

KHP-BI 12 DVN

KHP-BI 12 DTN

KHP-BI 14 DVN

KHP-BI 14 DTN

KHP-BI 16 DVN

KHP-BI 16 DTN

220-240/1/50

380-415/3/50

220-240/1/50

380-415/3/50

220-240/1/50

380-415/3/50

12.1

12

14

14

15.5

15.5

10400

10320

12040

12040

13330

13330

2.74

2.66

3.39

3.26

3.82

3.79

4.42

4.51

4.13

4.29

4.06

4.09

11.85

11.97

14.05

13.93

16.05

15.48

10190

10290

12080

11980

13800

13310

3.48

3.5

4.41

4.21

5.03

4.87

3.41

3.42

3.19

3.31

3.19

3.18

11.7

12

13.1

13.5

13.8

14.5

10060

10320

11260

11610

11870

12470

2.79

2.8

3.48

3.45

3.77

3.94

4.19

4.29

3.76

3.91

3.66

3.68

11.02

11.7

12.49

12.53

12.85

12.91

9480

10060

10740

10770

11050

11100

4.17

4.65

5.07

5.21

5.39

5.52

2.64

2.52

2.46

2.4

2.38

2.34

4.46-A++

4.58-A++

4.28-A++

4.62-A++

4.01-A++

4.37-A++

3.24-A++

3.23-A++

3.24-A++

3.31-A++

3.2-A+

3.29-A++

6.1

6.74

5.25

6.42

5.23

5.9

4.26

4.08

4.13

4.13

4.44

4.11

2

2

2

2

2

2

6250

6250

6250

6250

6250

6250

3.9

4.2

3.9

4.2

3.9

4.2

Double Rotary DC Inverter

R-410A Electric expansion valve 53.6

55.1

57.1

58.7

59.2

59.0

52.7

55.4

57.9

57.9

57.6

57.8

900

900

900

900

900

900

1327

1327

1327

1327

1327

1327

400

400

400

400

400

400

99

115

99

115

99

115

Ø9.5 (3/8”) Ø15.9(5/8”) 2/50

2/50

2/50

2/50

2/50

2/50

30

30

30

30

30

30

25

25

25

25

25

25

KIT KHP BI 16 TN

KIT KHP BI 16 VN

KIT KHP BI 16 TN

-20~35 -5~46 -20~43 KIT KHP BI 16 VN

KIT KHP BI 16 TN

KIT KHP BI 16 VN

99


DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM

AQUANTIA BIBLOC INDOOR UNIT TECHNICAL SPECIFICATIONS

MODEL

KIT KHP BI 8 VN

Power

Water outlet temperature ranges

Dimensions

Weight Water pipe connections diameter Safety valve

V/ph/Hz

220-240/1/50

KIT KHP BI 16 VN KIT KHP BI 16 TN 220-240/1/50

Heat

ºC

25 ~ 60

Cold

ºC

5 ~ 25

DOMESTIC HOT WATER

ºC

40 ~ 60

H

mm

865

Width

mm

400

Depth

mm

427

Kg

43

mm (inch)

L

Volume of expansion tank

L

0.3 4.7

5

Plates

Water pump pressure

mca (kPa)

Refrigerant circuit diameter (liquid)

mm (inch)

9.5(3/8)

Refrigerant circuit diameter (gas)

mm (inch)

15.9(5/8)

100

5

3

Heat exchanger type

Standard support heater

54

25(1")

Mpa

Total water volume

54

380-415/3/50

kW

6(×58.4)

3

7.5(×73.55)

3

7.5(×73.5)

4.5


R-410A

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

ACS

GENERAL CHARACTERISTICS HEATING An integrated system that provides heating, climate control and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed. • DC ventilator and compressor. • Climate control and domestic hot water from a single piece of equipment. • It can operate on its own or draw on other energy sources already installed. • A hydraulic system in an indoor unit and a heat pump in an outdoor unit.

+ + + +

RADIATORS

FANCOILS

COMBINATION OF THE ABOVE

CLIMATE CONTROL

+ + +

AQUANTIA BIBLOC

UNDERFLOOR HEATING

FANCOILS

COLD FLOOR

COMBINATION OF THE ABOVE

DOMESTIC HOT WATER

+

ACCUMULATION TANKS

TOUCH CONTROL SMART, ADAPTABLE SYSTEM EASY INSTALLATION, MINIMAL MAINTENANCE POMPE À CHALEUR

WIDE RANGE OF OPERATING TEMPERATURES

101


DOMESTIC HOT WATER RANGE TANKS FOR DOMESTIC HOT WATER

TANKS FOR DOMESTIC HOT WATER TECHNICAL SPECIFICATIONS

MODEL Capacity

L.

Heat Exchanger type

Dimensions

BSX160

BSX190

BSX270

160

190

270

Heat coil

Heat coil

Heat coil

Height

mm

1124

1315

1209

Diameter

mm

Ø 590

Ø 590

Ø 700

Floor including front cover

mm

630

630

740

Kg

104

123

136

Net weight Upper heat coil entrance diameter

Inches

-

-

-

Upper heat coil exit diameter

Inches

-

-

-

m2

-

-

-

Lower heat coil entrance diameter

Inches

1"

1"

1"

Lower heat coil exit diameter

Inches

1"

1"

1"

m2

1.21

1.85

2.48

Cold water inlet

Inches

3/4”

3/4”

1"

Heat water outlet

Inches

3/4”

3/4”

1"

Circulation

Inches

3/4”

3/4”

1"

mm

280

280

280

Area of upper heat coil

Area of lower heat coil

Cleaning cap Tank protective cap material

Steel

Interior cover

Coat of enamel

Exterior cover

Galvanized steel with electrostatic coating with powdered paint.

Casing colour

White

Plugs and exterior cap material Insulating material and thickness Input of sensors for the automatic control of the unit

Black coloured plastic

mm

Injected polyurethane foam, 50 mm

Ø / depth (mm)

3 units, Ø13 x 100

Operating pressure

bar

10

10

10

Test pressure

bar

13

13

13

Temperature indicator Anti-corrosive protection

102

Analogue thermometer Magnesium anode rod and tester


ACS

MODEL Capacity

L.

Heat Exchanger type

Dimensions

BS475

KAYSUN G-751

475

750

Heat coil

Heat coil

Height

mm

1800

2010

Diameter

mm

Ø 750

Ø 940

Floor including front cover

mm

790

1000

Kg

192

285

Net weight Upper heat coil entrance diameter

Inches

-

-

Upper heat coil exit diameter

Inches

-

-

m2

-

-

Area of upper heat coil Lower heat coil entrance diameter

Inches

1 1/4"

1 1/4"

Lower heat coil exit diameter

Inches

1 1/4"

1 1/4"

2.13

4.87

Area of lower heat coil

m2

Cold water inlet

Inches

1"

1 1/4"

Heat water outlet

Inches

1"

1 1/4"

Circulation

Inches

1"

1 1/4"

280

DN200

Coat of enamel

Low carbon steel

Interior cover

Steel

Double coat of vitrified Enamel

Exterior cover

Galvanised steel with electrostatic coating with powdered paint.

Soft PVC coating

Casing colour

White

Yellow

Cleaning cap

mm

Tank protective cap material

Plugs and exterior cap material Insulating material and thickness Input of sensors for the automatic control of the unit

Black coloured plastic

mm Ø / depth (mm)

Injected polyurethane foam, 50 mm 3 units, Ø13 x 100

1 units 1/2”

Operating pressure

bar

10

9

Test pressure

bar

13

18

Temperature indicator Anti-corrosive protection

Analogue thermometer Magnesium anode rod and tester

103

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution


DOMESTIC HOT WATER RANGE TANKS FOR DOMESTIC HOT WATER

TANKS FOR DOMESTIC HOT WATER TECHNICAL SPECIFICATIONS

MODEL

KAYSUN G-1001 KAYSUN G-1002 KAYSUN G-1501 KAYSUN G-2001

Capacity

L.

Heat Exchanger type

Dimensions

1000

1000

1500

2000

Heat coil

Double heat coil

Heat coil

Heat coil

Height

mm

2015

2015

2050

2060

Diameter

mm

Ø 1000

Ø 1000

Ø 1200

Ø 1350

Floor including front cover

mm

1065

1065

1300

1450

Kg

340

350

520

570

Net weight Upper heat coil entrance diameter

Inches

-

1 1/4"

-

-

Upper heat coil exit diameter

Inches

-

1 1/4"

-

-

m2

-

1.8

-

-

Area of upper heat coil Lower heat coil entrance diameter

Inches

1 1/4"

1 1/4"

1 1/4"

1 1/4"

Lower heat coil exit diameter

Inches

1 1/4"

1 1/4"

1 1/4"

1 1/4"

m2

5.06

3.86

6.83

7.52

Cold water inlet

Inches

1 1/4"

1 1/4"

1 1/4"

1 1/4"

Heat water outlet

Inches

1 1/4"

1 1/4"

1 1/4"

1 1/4"

Circulation

Inches

1 1/4"

1 1/4"

1 1/4"

1 1/4"

mm

DN200

DN200

DN400

DN400

Area of lower heat coil

Cleaning cap Tank protective cap material

Low carbon steel

Interior cover

Double coat of vitrified Enamel

Exterior cover

Soft PVC coating

Casing colour

Yellow

Plugs and exterior cap material Insulating material and thickness Input of sensors for the automatic control of the unit

Black coloured plastic

mm Inches

Insulating foam, 75 mm 1 unit 1/2”

2 units 1/2" each

1 unit 1/2”

2 units 1/2" each

Operating pressure

bar

9

9

9

9

Test pressure

bar

18

18

18

18

Temperature indicator Anti-corrosive protection

104

Analogue thermometer Magnesium anode rod and tester


ACS

GENERAL CHARACTERISTICS

The Aquatix range is fitted with tanks for domestic hot water and underfloor heating. These tanks are an ideal complement for Aquantia systems.

• Optional 2kW supplementary heater with thermostat.

When there are two heat coils available, the upper heat coil is connected to a domestic hot water heat pump, while the other heat coil can be used for hot water from a solar thermal system or a conventional boiler.

• Analogue thermometer to know the temperature of the upper side of the tank.

• Magnesium protection anode to avoid internal corrosion of the tank. Malfunction test included.

• 1-2 heat coils available inside the unit.

BS AND BSX DEPOSIT

DEPOSIT G (1 HEAT COIL)

DEPOSIT G (2 HEAT COILS)

ACCESSORY RT1, heater of 2 kW with thermostat for models GRT2, heater of 2 kW with thermostat for models B-

105

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution


DOMESTIC HOT WATER RANGE ACCUMULATORS

COMPAK

POMPE À CHALEUR

TECHNICAL SPECIFICATIONS MODEL Power

COMPAK KHP 15 190 ACS1

COMPAK KHP 35 300 ACS1

220-240/1/50

220-240/1/50

Economy

Economy

ºC

-7~43

-7~43

kW

1.45

3

1.25

2.58

0.38

0.80

3.8

3.83

A

2.3

4.1

m3/h

0.043

0.086

kW

3.15

3.15

Double

Double

Kg

1

1.2

ºC

Default 60ºC (Adjustable: 38ºC-70ºC)

V/ph/Hz

Operation mode Room temperature Heating Capacity

kCal/h TECHNICAL SPECIFICATIONS

Nominal input

kW

COP Rated current Water flow Electrical heater Compressor type Amount of R-134A refrigerant Evaporator material

Hydrophilic aluminium fin, inner-grooved copper tube

Output water temperature Heat exchanger

Water pipeline

Copper tubing around the tank

Water inlet

mm

DN 20

DN 20

Water outlet

mm

DN 20

DN 20

Drainage pipe

mm

DN 20

DN 20

Safety valve

mm

DN 20

DN 20

Max. Pressure

MPa

1

1

mm

Ø568x1760

Ø650x1920

l

180

280

Kg

107

145.5

dB (A)

41.2

45

mm

ø160

ø190

Static Pressure

Pa

25

25

Max. Length

m

10

10

m3/h

270/230/182

414/355/312

Yes

Yes

Dimension Tank volume Net weight Sound Pressure Level Diameter Air intake and outlet

Outdoor airflow Anti-Legionella function

Rated capacities based on the following conditions: Outdoor temperature 15/12ºC (dry bulb / wet bulb), water inlet / outlet 15/45ºC. Sound pressure at 1 meter distance from the unit.

106

Default 55ºC (Adjustable: 38ºC-65ºC)


R-134A

ACS

GENERAL CHARACTERISTICS Domestic hot water storage or underfloor heating using heat pump technology. Provides water temperatures of up to 70ºC. It is fitted with a condenser located around the tank to avoid contact between refrigerant and sanitary hot water. It also includes a magnesium protection anode to avoid internal corrosion of the tank. • Compact design and easy installation. • LCD screen control display. • They must be protected against solar radiation. • Built-in relief valve. • Non-programmable hybrid mode.

COMPAK KHP 15 190 ACS1

OPERATION MODE

+ + + +

ECONOMY: only the heating pump operates

ELECTRICAL HEATER for additional heating

HYBRID: use of the heat pump + heater

MAGESIUM ANODE in all models

COMPAK KHP 35 300 ACS1

PRICE LIST MODEL COMPAK KHP 15 190 ACS1 COMPAK KHP 35 300 ACS1

107

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution


DOMESTIC HOT WATER RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

RAFA NADAL INTERNATIONAL CENTRE PUBLIC BUILDING Location: Balearic Islands Initial situation: New construction Units installed: Aquatix Systems Capacity: 7 kW

108


AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

109


DOMESTIC HOT WATER RANGE KEY INSTALLATIONS

AQUATIX IS A MORE SUSTAINABLE SOLUTION THAN THE TRADITIONAL HOT WATER BOILER, WITH BETTER ENERGY EFFICIENCY AND A QUICKER AND MORE SIMPLE INSTALLATION PROCESS. ENERGY SAVINGS AND EFFICIENCY SET THIS RANGE APART.

ON HOTELS OCEANFRONT HOTEL

Location: Matalascañas Initial situation: Renovation Units installed: 2 KHP 420 ACS1 Capacity: 80 kW

110


RUBER HOSPITAL

ITEVE

PUBLIC BUILDING

BUSINESS CENTRE

Location: Madrid Initial situation: Renovation Units installed: AIR-WATER Capacity: 130 kW

Location: Badajoz (Extremadura) Initial situation: Renovation Units installed: Compak KHP Capacity: 245 kW

QUIRÓN HOSPITAL

INSTITUTION ST. LOUIS

PUBLIC BUILDING

SCHOOL

Location: Torrevieja Initial situation: New construction Units installed: AIR-WATER Capacity: 65 kW

Location: France Initial situation: Renovation Units installed: KHP 72 ACS + G1 Capacity: 6.5 kW

JARDINES DE LORCA

SYNERGYM

HOTEL

GYM

Location: Murcia Initial situation: New construction Units installed: AIR-WATER Capacity: 260 kW

AQUATIX DOMESTIC HOT WATER

Inspiration, Innovation, Evolution

Location: GYM Initial situation: Renovation Units installed: 5 KHP 35 300 ACS1 Capacity: 18 kW

111


ZEN R-410A COMMERCIAL RANGE

INTRODUCTION TO THE PRODUCT RANGE............................................114 SETS.............................................................................................................116 CASSETTE (600X600)..........................................................................118 SUPERSLIM CASSETTE.......................................................................120 FLOOR / CEILING............................................................................... ..124 DUCTS...................................................................................................128 FLOOR STANDING............................................................................. ..132 TWINS....................................................................................................... ..134 KEY INSTALLATIONS............................................................................... 136


ZEN R-410A COMMERCIAL

ZEN

R-410A COMMERCIAL RANGE


R-410A COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

ZEN

R-410 COMMERCIAL RANGE

“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”

Introducing the KAYSUN commercial range with axial and centrifugal outdoor fans with R-410A refrigerant. The most outstanding features of the axial outdoor fans fitted in this range are: advanced technology, efficiency, versatility and high performance. Regarding centrifugal outdoor fans , we could say that their main feature is adaptability. This unit is perfect for indoor spaces with no room for an axial outdoor fan.

The combination systems with outdoor centrifugal units are pieces of equipment with a compressor and indoor ventilators with DC Inverter technology. These units with a centrifugal ventilator embody one of our key principles (versatility) and have been created to provide a customised solution that is suited to the need to integrate them into the facade of street premises.

Combination systems with axial outdoor units are fitted with Inverter technology ,thereby, optimising energy efficiency and seasonal performance indicators with a SCOP 4.0.. The outdoor units of this type have an aesthetic with a robust design and good sound performance.

Within the ZEN we have a wide variety of indoor units: Compact Cassette (600x600), Superslim Cassette (840x840), Floor/ Ceiling units and, our new product, Ducts systems. Some of these units can be installed in a TWINS configuration: one outdoor unit with two indoor units working together.

AXIAL OUTDOOR UNITS We wish to highlight the axial outdoor units of Kaysun’s Zen range. These units designed to make maintenance tasks easier and protect its main components in order to extend the life cycle of the product.

+ +

R-410A

+

STRONGER AND COMPACT

PERFORMANCE

ENERGY SAVING

SOUND LEVEL

CENTRIFUGAL OUTDOOR UNITS The centrifugal outdoor units offered by KAYSUN are a highly recommended option for systems where there is no outdoor space for installation.

R-410A

+ + +

114

14 AND 16 KW

FLEXIBLE CONFIGUATION CONDENSATION AIR INLET AND OUTLET 60 PA AVAILABLE PRESURE


Inspiration, Innovation, Evolution

DUCT UNIT

NEW

• Removable filter (it can be extracted without touching the unit). • Flange for fitting the outlet duct. • Flange for fitting the intlet (return) duct. • Double return system possibility rear or lower inlet. • Condensation pump. • Pre-installation for fresh air inlet. • Electric box removable up to 1 metre apart from the unit's body.

R-410A

• On/Off and Alarm dry contacts. • The KC-03.1 SPS controller allows adjusting the available pressure automatically. • Up to 160 Pa available depending on the model. • Horizontal and vertical installation. • Reduced height unit.

Compatible with

TWO COMMUNICATION WIRES

x2

The ZEN range units* only require two shielded wires without polarity to carry out the operation. This new characteristic makes the communication wiring works cheaper and easier. *Except for 3.5 kW unit.

K03 WIFI LCAC

NEW

has an optional WiFi adapter for some of its indoor unit models in the ZEN range. This accessory, connect the unit to our domestic WiFi network and control it through an App installed on our Smartphone. The application also includes a weekly timer built into the App to ease and improve the control function of our air-conditioning system.

S1 S2

S1 S2

115

ZEN R-410A COMMERCIAL

With regard to the indoor units of the ZEN RANGE,we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:


R-410A COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

CASSETTE R-410A

116


Inspiration, Innovation, Evolution

POWER kW

3.5

5.2

7.1

9.0

10.5

12.5

14.0

16.0

SETS CASSETTE (600 X 600) KCI-52 DVN10

ZEN R-410A COMMERCIAL

KCI-35 DVN11

(Page 118)

SUPERSLIM CASSETTE AXIAL OUTDOOR UNIT KCIS-52 DVN11

(Page 122)

KCIS-71 DVN11

CENTRIFUGAL OUTDOOR UNIT

KCIS-90 DVN10

KCIS-105 DVN11 KCIS-125 DVN10 KCIS-140 DVN11 KCIS-105 DTN11 KCIS-125 DTN10 KCIS-140 DTN11

KCIS-160 DTN11

(Page 121) KCISC-140 DTN11 KCISC-160 DTN11

FLOOR / CEILING AXIAL OUTDOOR UNIT KPC-52 DVN11

(Page 126) KPC-71 DVN11

CENTRIFUGAL OUTDOOR UNIT

KPC-90 DVN10

KPC-105 DVN11 KPC-125 DVN10 KPC-105 DTN11 KPC-125 DTN10

KPC-140 DVN11 KPC-140 DTN11

KPC-160 DTN11

(Page 125) KPCC-140 DTN11 KPCC-160 DTN11

Ducts

NEW

AXIAL OUTDOOR UNIT KPD-35 DVN11

KPD-52 DVN11

(Page 130)

KPD-71 DVN11

CENTRIFUGAL OUTDOOR UNIT

KPD-90 DVN11

KPD-105 DVN11 KPD-125 DVN10 KPD-140 DVN11 KPD-105 DTN11 KPD-125 DTN10 KPD-140 DTN11

KPD-160 DTN11

(Page 129) KPDC-140 DTN11 KPDC-160 DTN11

FLOOR STANDING AXIAL OUTDOOR UNIT

UNTIL END OF STOCK

(Page 133) KPV-140 DVN10 KPV-140 DTN10

CENTRIFUGAL OUTDOOR UNIT

(Page 133) KPVC-140 DTN10

117


R-410A COMMERCIAL RANGE CASSETTE SETS (600X600)

CASSETTE (600x600) GENERAL CHARACTERISTICS

The Cassette Artflux 360º 600x600 units stands out from other units thanks to its elegant design. Their small dimensions allows them for adapting to false ceiling installations and their 360º air flow provides user with highest comfort and covers every corner of the room.

Pre-installed inlet for fresh air.

Compact unit with integrated electric box.

Standard condensation pump.

Voltage-free alarm and ON/OFF dry contacts.

The 5.2 kW unit is compatible with TWINS configuration.

360º airflow.

+

STANDARD CONDENSATION PUMP

KID-02 S (*) RECOMMENDED

NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers Range

INDIVIDUAL

KID-02 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KC-02.1 H

KC-01 S

KCT-02.1 SR

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

118

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

4.0 R-410A

x2

SCOP

50/60 Hz

!

AXIAL SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./rated/max.) Heating capacity (min./rated/max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC

kW Kcal/h W

kW Kcal/h W

kW

INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Width/Height/Depth (panel) Net weight (panel) Power wiring Shielded communication wires*** Power supply

m /h dB (A) mm Kg mm Kg mm2 mm2 V / F / Hz 3

AXIAL OUTDOOR UNIT Compressor type Outdoor airflow Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires*** Power supply

m3/h dB (A) gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

KCI-35 DVN11

KCI-52 DVN10

0.85/3.52/4.13

0.79/5.28/6.15

731/3027/3552

679/4540/5288

168/1080/1539

0.270/1.630/2.365

6.1

6.3

A++

A++

0.47/4.1/4.41

0.88/5.57/7.03

404/3526/3793

757/4789/6045

124/1060/1361

0.295/1.500/2.510

4.0

4.0

A+

A+

3.18

4.25

3.08

2.77

KCI-35 DR11

KCI-52 DN10

617/504/416

660/550/490

35

38

570/260/570

570/260/570

16.2

16.5

647/50/647

647/50/647

2.5

2.5

with communication

(2+T)x2.5

(3+T)x2.5

2x1.5

220-240/1/50

220-240/1/50

KUE-35 DVN11

KUE-52 DVN10

Rotary

Rotary

2000

2100

56

56.5

R-410A

R-410A

1050 / 15

1780 / 15

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

ø12.7 (1/2")

25

30

10

20

800/554/333

800/554/333

29.9

35.5

(2+T)x2.5

(2+T)x2.5

(3+T)x2.5

2x1.5

220-240/1/50

220-240/1/50

ZEN R-410A COMMERCIAL

TECHNICAL SPECIFICATIONS

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. *** Except for 35 (3.5 kW) models. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

119


R-410A COMMERCIAL RANGE SUPERSLIM CASSETTE TYPE SETS

SUPERSLIM CASSETTE GENERAL CHARACTERISTICS In order to provide users with maximum comfort, the cassette units are fitted with a 360° air diffusion system that allows them to reach every corner of the room. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings. •

Outdoor air intake pipeline assembly (optional).

Slim design compact unit.

Standard condensation pump.

Alarm and ON/OFF dry contacts.

Louvers position storage.

360º airflow.

Units 52, 71 and 90 are compatible with TWINS configuration.

Prepared for side ducts (closing air outlets).

+

TWINS COMBINATIONS (OPTIONAL)

+

STANDARD CONDENSATION PUMP

KID-02 S (*) RECOMMENDED

NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY Compatible with DR11 units. UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

CENTRALISED

KCCT-64 I (B)

KID-02 S

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

120

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

x2

R-410A

DC

!

DC INDOOR

CENTRIFUGAL SET Cooling capacity Cooling capacity Cooling input Heating Capacity Heating Capacity Heating input Heating capacity -7ºC

kW Kcal/h kW kW Kcal/h kW kW

INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Width/Height/Depth (panel) Net weight (panel) Power wiring Shielded communication wires Power supply

m /h dB (A) mm Kg mm Kg mm2 mm2 V / F / Hz 3

CENTRIFUGAL OUTDOOR UNITS Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply

KCISC-140 DTN11

KCISC-160 DTN11

12.6

16.11

10836

13855

5.49

6.76

12.89

16.99

11085

14611

4.67

6.13

9

11

KCIS-140 DR11

KCIS-160 DR11

1715/1568/1381

1970/1737/1537

49

48

840/287/840

840/287/840

29

29.7

950/55/950

950/55/950

5

5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

KUEC-140 DTN10

KUEC-160 DTN10

Scroll

Scroll

m3/h / Pa dB (A)

3600/60

3600/60

64

64

R-410A

R-410A

gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

4300/30

4300/30

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

65

30

30

1394/568/783

1394/568/783

177

177

(4+T)x4

(4+T)x4

2x1.5

2x1.5

380-400/3/50

380-400/3/50

ZEN R-410A COMMERCIAL

TECHNICAL SPECIFICATIONS

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

121


R-410A COMMERCIAL RANGE SUPERSLIM CASSETTE TYPE SETS

SUPERSLIM CASSETTE TECHNICAL SPECIFICATIONS AXIAL SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./nom./max.) Heating capacity (min./nom./max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC

kW Kcal/h kW

kW Kcal/h kW

kW

INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Width/Height/Depth (panel) Net weight (panel) Power wiring Shielded communication wires Power supply

m3/h dB (A) mm Kg mm Kg mm2 mm2 V / F / Hz

AXIAL OUTDOOR UNIT Compressor type Outdoor airflow Sound pressure Refrigerant Refrigerant charge / Additional charge** Liquid pipe Liquid Liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply

m /h dB (A) 3

gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

KCIS-52 DVN11

KCIS-71 DVN11

KCIS-90 DVN10

KCIS-105 DVN11

0.79/5.28/6.15

1.20/7.03/8.21

2.08/8.79/10.55

2.93/10.55/12.09

679/4540/5289

1032/6045/7061

1789/7559/9073

2520/9073/10397

0.26/1.68/2.36

0.40/2.17/3.15

0.69/2.76/4.05

0.97/4.06/4.62

6.3

6.1

6.1

6.1

A++

A++

A++

A++

0.88/5.67/7.03

1.20/7.20/8.65

2.08/9.08/10.52

2.64/11.13/13.19

757/4876/6046

1032/6192/7439

1789/7809/9047

2296/9572/11343

0.29/1.46/2.51

0.40/2.05/3.09

0.69/2.38/3.75

0.88/3.08/4.69

4.0

4.0

4.0

4.0

A+

A+

A+

A+

4.33

5.13

6.99

8.76

2.52

2.53

2.50

2.48

KCIS-52 DR11

KCIS-71 DR11

KCIS-90 DN10

KCIS-105 DR11

1036/867/763

1378/1200/1032

1700/1460/1300

1775/1620/1438

37

40

44

46

840/205/840

840/245/840

840/245/840

840/245/840

21.4

23

26.5

27.5

950/55/950

950/55/950

950/55/950

950/55/950

5

5

5

5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KUE-52 DVN10

KUE-71 DVN10

KUE-90 DVN10

KUE-105 DVN10

Rotary

Double rotary

Double rotary

Double rotary

2100

2700

4300

4300

56.5

60.5

59.5

61

R-410A

R-410A

R-410A

R-410A

1780 / 15

1950 / 30

2800 / 30

3200 / 30

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

30

50

50

65

20

25

25

30

800/554/333

845/702/363

946/810/410

946/810/410

35.5

49

62.9

67.2

(2+T)x2.5

(2+T)x2.5

(2+T)x4

(2+T)x4

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

122


Inspiration, Innovation, Evolution

4.0 SCOP

R-410A

x2

50/60 Hz

!

KCIS-105 DTN11

KCIS-125 DVN10

KCIS-125 DTN10

KCIS-140 DVN11

KCIS-140 DTN11

KCIS-160 DTN11

2.93/10.55/12.02

3.22/12.31/13.19

3.22/12.31/13.19

3.99/14.07/16.12

3.99/14.07/16.12

4.98/15.53/18.46

2520/9073/10337

2769/10586/11343

2769/10586/11343

3431/12100/13863

3431/12100/13863

4282/13356/15875

0.97/4.06/4.62

1.07/4.09/5.07

1.07/4.09/5.07

1.33/5.39/6.20

1.33/5.39/6.20

1.66/6.40/7.10

6.1

5.6

5.6

5.6

5.6

5.6

A++

A+

A+

A+

A+

A+

2.64/11.13/13.19

2.93/13.48/14.65

3.4/12.89/14.5

4.19/16.12/17.59

4.19/16.12/17.59

5.28/18.17/20.51

2296/9572/11343

2520/11593/12599

2924/11085/12470

3603/13863/15127

3603/13863/15127

4540/15626/17638

0.88/3.08/4.69

0.97/3.53/5.23

0.97/3.53/5.23

1.40/5.35/6.76

1.40/5.35/6.76

1.76/5.73/7.32

4.0

4.0

4.0

4.0

4.0

4.0

A+

A+

A+

A+

A+

A+

8.93

9.73

9.73

10.17

10.17

10.17

2.44

2.75

2.78

2.29

2.60

2.66

KCIS-105 DR11

KCIS-125 DN10

KCIS-125 DN10

KCIS-140 DR11

KCIS-140 DR11

KCIS-160 DR11

1775/1620/1438

1850/1600/1400

1850/1600/1400

1715/1568/1381

1715/1568/1381

1970/1737/1537

46

48

48

49

49

48

840/245/840

840/287/840

840/287/840

840/287/840

840/287/840

840/287/840

27.5

26.1

26.1

29

29

29.7

950/55/950

950/55/950

950/55/950

950/55/950

950/55/950

950/55/950

5

5

5

5

5

5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KUE-105 DTN10

KUE-125 DVN10

KUE-125 DTN10

KUE-140 DVN10

KUE-140 DTN10

KUE-160 DTN10

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

4300

4300

4300

6800

6800

7200

62

62.5

63

65

65

62.5

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

3200 / 30

3650 / 30

3650 / 30

4000 / 30

4000 / 30

4300 / 30

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8") 65

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

ø15.9 (5/8") 65

65

65

65

30

30

30

30

30

30

946/810/410

946/810/410

946/810/410

952/1333/415

952/1333/415

952/1333/415

78.9

70.5

85

95.1

108.1

112.8

(4+T)x2.5

(2+T)x4

(4+T)x2.5

(2+T)x6

(4+T)x4

(4+T)x6

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

380-400/3/50

220-240/1/50

380-400/3/50

220-240/1/50

380-400/3/50

380-400/3/50

123

ZEN R-410A COMMERCIAL

UNTIL END OF STOCK


R-410A COMMERCIAL RANGE FLOOR / CEILING SETS

FLOOR / CEILING GENERAL CHARACTERISTICS

Kaysun Zen range makes air conditioning at your disposal through its most versatile product, the Floor/Ceiling units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit compatible with centrifugal outdoor units. •

Easy access to components for maintenance.

Improved airflow for a greater comfort.

FLOOR or CEILING installation.

Voltage-free alarm and ON/OFF dry contacts.

New numerical display in the receiver.

Optional wired controller.

+

COMPATIBLE WITH WALL-MOUNTED / CEILING UNITS

ALARM AND ON/OFF DRY CONTACTS

+

NEW KID-02 S

OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

(*) RECOMMENDED

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers Range

INDIVIDUAL

KID-02 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KC-03.1 SPS

KC-03 SPS

KC-02.1 H

KC-01 S

KCT-02.1 SR

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

124

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

R-410A

x2

DC

!

DC

CENTRIFUGAL SET Cooling capacity Cooling capacity Cooling input Heating Capacity Heating Capacity Heating input Heating capacity -7ºC

kW Kcal/h kW kW Kcal/h kW kW

INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/height/depth (ceiling installation) Net weight Power wiring Shielded communication wires Power supply

m3/h dB (A) mm Kg mm2 mm2 V / F / Hz

CENTRIFUGAL OUTDOOR UNITS Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply

m /h / Pa dB (A) 3

gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

KPCC-140 DTN11

KPCC-160 DTN11

13.5

16

11610

13760

5.885

6.891

14.65

17

12599

14620

5.657

6.468

9.82

10.88

KPC-140 DR11

KPC-160 DR11

2329/1930/1417

2454/1834/1426

46

42

1650/235/675

1650/235/675

41.2

41.4

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

KUEC-140 DTN10

KUEC-160 DTN10

Scroll

Scroll

3600/60

3600/60

64

64

R-410A

R-410A

4300 / 30

4300 / 30

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

65

30

30

1394/568/783

1394/568/783

177

177

(4+T)x4

(4+T)x4

2x1.5

2x1.5

380-400/3/50

380-400/3/50

ZEN R-410A COMMERCIAL

TECHNICAL SPECIFICATIONS

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

125


R-410A COMMERCIAL RANGE FLOOR / CEILING SETS

FLOOR / CEILING TECHNICAL SPECIFICATIONS KPC-52 DVN11

AXIAL SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./rated/max.) Heating capacity (min./rated/max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC

kW Kcal/h kW

kW Kcal/h kW

kW

INDOOR UNIT

Indoor airflow Sound pressure (low speed) Width/height/depth (ceiling installation) Net weight Power wiring Shielded communication wires Power supply

m3/h dB (A) mm Kg mm2 mm2 V / F / Hz

KPC-105 DVN11

0.79/5.28/6.15

1.2/7.03/8.21

2.08/8.79/10.55

2.93/10.55/12.02

679/4541/5289

1032/6046/7061

1789/7559/9073

2520/9073/10337

0.27/1.63/2.37

0.4/2.29/3.16

0.69/2.96/4.06

0.98/4.06/4.62

6.5

6.1

6.1

6.3

A++

A++

A++

A++

0.88/5.67/7.03

1.2/7.62/8.65

2.08/9.38/10.84

2.64/11.13/13.19

757/4876/6046

1032/6553/7439

1789/8067/9322

2270/9572/11343

0.26/1.46/2.51

0.4/2.05/3.09

0.69/2.48/3.87

0.88/2.99/4.69

4.0

4.0

4.0

4.0

A+

A+

A+

A+

4.33

5.13

7.25

9.29

2.61

2.64

2.53

2.48

KPC-52 DR11

KPC-71 DR11

KPC-90 DN10

KPC-105 DR11

902/786/677

1208/1066/853

1650/1450/1250

2160/1844/1431

37

41

44

42

1068/235/675

1068/235/675

1285/235/675

1650/235/675

26.6

26.8

31

40.3

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KUE-71 DVN10

KUE-90 DVN10

KUE-105 DVN10

Rotary

Double rotary

Double rotary

Double rotary

m3/h dB (A)

2100

2700

4300

4300

56.5

60.5

59.5

61

R-410A

R-410A

R-410A

R-410A

gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

1780 / 15

1950 / 30

2800 / 30

3200 / 30

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

30

50

50

65

20

25

25

30

800/554/333

845/702/363

946/810/410

946/810/410

35.5

49

62.9

67.2

(2+T)x2.5

(2+T)x2.5

(2+T)x4

(2+T)x4

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

126

KPC-90 DVN10

KUE-52 DVN10

AXIAL OUTDOOR UNIT Compressor type Outdoor airflow Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply

KPC-71 DVN11


Inspiration, Innovation, Evolution

4.0 R-410A

x2

SCOP

50/60 Hz

!

UNTIL END OF STOCK

KPC-125 DVN10

KPC-125 DTN10

KPC-140 DVN11

KPC-140 DTN11

KPC-160 DTN11

2.93/10.55/12.02

3.22/12.31/13.19

3.22/12.31/13.19

4.1/14.07/16.41

4.1/14.07/16.41

4.98/15.82/18.11

2520/9073/10337

2769/10587/11343

2769/10587/11343

3526/12100/14113

3526/12100/14113

4283/13605/15575

0.98/4.06/4.62

1.07/4.23/5.07

1.07/4.23/5.07

1.37/5.19/6.31

1.37/5.19/6.31

1.66/6.06/6.97

6.1

6.1

6.1

6.1

6.1

6.1

A++

A++

A++

A++

A++

A++

2.64/11.13/13.19

3/13.5/14.7

2.84/12.9/14.01

4.4/16.12/18.46

4.4/16.12/18.46

5.28/18.17/20.51

2270/9572/11343

2580/11610/12642

2442/11103/12049

3784/13863/15876

3784/13863/15876

4541/15626/17639

0.88/2.99/4.69

0.95/3.54/5

0.95/3.54/5

1.47/4.07/6.59

1.47/4.07/6.59

1.76/5.65/7.32

4.0

4.0

4.0

4.0

4.0

4.0

A+

A+

A+

A+

A+

A+

9.11

9.73

9.73

10.44

10.44

10.62

2.43

2.61

2.73

2.54

2.71

2.76

KPC-105 DR11

KPC-125 DN10

KPC-125 DN10

KPC-140 DR11

KPC-140 DR11

KPC-160 DR11

2160/1844/1431

2271/1886/1394

2100/1800/1400

2329/1930/1417

2329/1930/1417

2454/1834/1426

42

43

41

46

46

45

1650/235/675

1650/235/675

1650/235/675

1650/235/675

1650/235/675

1650/235/675

40.3

40.5

40.5

41.2

41.2

41.4

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KUE-105 DTN10

KUE-125 DVN10

KUE-125 DTN10

KUE-140 DVN10

KUE-140 DTN10

KUE-160 DTN10

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

4300

4300

4300

6800

6800

7200

62

62.5

63

65

65

62.5

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

3200 / 30

3650 / 30

3650 / 30

4000 / 30

4000 / 30

4300 / 30

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8") 65

ø15.9 (5/8") 65

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

65

65

65

30

30

30

30

30

30

946/810/410

946/810/410

946/810/410

952/1333/415

952/1333/415

952/1333/415

78.9

70.5

85

95.1

108.1

112.8

(4+T)x2.5

(2+T)x4

(4+T)x2.5

(2+T)x6

(4+T)x4

(4+T)x6

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

380-400/3/50

220-240/1/50

380-400/3/50

220-240/1/50

380-400/3/50

380-400/3/50

127

ZEN R-410A COMMERCIAL

KPC-105 DTN11


R-410A COMMERCIAL RANGE DUCTS SETS

Ducts

NEW

GENERAL CHARACTERISTICS The new Kaysun ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design. •

Easily removable filter.

Up to 160 Pa available depending on the model.

Flanges in the inlet and outlet mouth.

Standard condensation pump of up to 750 mm in height.

Possibility for double air intake (rear or lower intake).

Fresh air intake at a side of the unit.

The KC-03.1 SPS controller allows adjusting the available pressure automatically.

Voltage-free alarm and ON/OFF dry contacts.

Horizontal and vertical installation.

Electric box removable up to 1 metre apart from the unit's body.

Reduced height unit.

+ +

STANDARD CONDENSATION PUMP up to 750 mm HEIGHT

VERTICAL INSTALLATION (OPTIONAL)

Compatible with

NEW KC-03.1 SPS

OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

(*) RECOMMENDED

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

For further information, please see our Controllers Range

INDIVIDUAL

KID-02 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KC-03.1 SPS

KC-03 SPS

KC-02.1 H

KC-01 S

KCT-02.1 SR

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

128

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

x2

R-410A

DC

!

DC

TECHNICAL SPECIFICATIONS

Cooling capacity Cooling capacity Cooling input Heating Capacity Heating Capacity Heating input Heating capacity -7ºC

kW Kcal/h kW kW Kcal/h kW kW

INDOOR UNIT Air flow Maximum pressure available Sound pressure (low speed) Width/Height/Depth Net weight Power wiring Shielded communication wires Power supply

m /h Pa dB (A) mm Kg mm2 mm2 V / F / Hz 3

CENTRIFUGAL OUTDOOR UNITS Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply

m /h / Pa dB (A) 3

gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

KPDC-160 DTN11

13.5

16

11610

13760

5.483

6.281

14.65

17

12599

14620

4.962

5.775

10

12

KPD-140 DR11

KPD-160 DR11

2900/2600/2100

2900/2600/2100

160

160

48

50.5

1200/300/874

1200/300/874

47.6

47.6

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

KUEC-140 DTN10

KUEC-160 DTN10

Scroll

Scroll

3600/60

3600/60

64

64

R-410A

R-410A

4300/30

4300/30

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

65

30

30

1394/568/783

1394/568/783

177

177

(4+T)x4

(4+T)x4

2x1.5

2x1.5

380-400/3/50

380-400/3/50

ZEN R-410A COMMERCIAL

KPDC-140 DTN11

CENTRIFUGAL SET

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

129


R-410A COMMERCIAL RANGE DUCTS SETS

Ducts

NEW

TECHNICAL SPECIFICATIONS KPD-35 DVN11

KPD-52 DVN11

KPD-71 DVN11

KPD-90 DVN11

KPD-105 DVN11

Cooling capacity (min./rated/max.)

kW

0.53/3.52/3.75

1.23/5.28/6.15

1.99/7.03/8.21

2.20/8.79/10.55

2.40/10.55/12.01

Cooling capacity (min./rated/max.)

Kcal/h

456/3027/3225

1058/4541/5289

1711/6046/7061

1892/7559/9073

2064/9073/10329

kW

0.16/1.24/1.6

0.26/1.64/2.12

0.45/2.18/2.80

0.50/2.84/3.20

0.66/4.06/4.38

5.6

6.1

6.1

6.1

6.3

AXIAL SET

Cooling input (min./rated/max.) SEER

A+

A++

A++

A++

A++

Heating capacity (min./rated/max.)

kW

1.00/3.81/3.99

1.80/5.57/7.03

2.40/7.62/8.65

2.70/9.38/10.84

2.78/11.14/13.20

Heating capacity (min./rated/max.)

Kcal/h

860/3277/3431

1548/4790/6046

2061/6553/7439

2322/8067/9322

2391/9580/11352

kW

0.30/1.20/1.40

0.31/1.54/2.15

0.48/2.05/2.85

0.55/2.29/3.25

0.65/3.09/4.40

SCOP

4.0

4.0

4.0

4.0

4.0

Heating efficiency class

A+

A+

A+

A+

A+

2.92

4.16

5.13

7.25

9.29

2.57

2.51

2.68

2.6

2.56

Cooling energy class

Heating input (min./rated/max.)

Heating capacity -7ºC

kW

COP -7ºC

KPD-35 DR11

KPD-52 DR11

KPD-71 DR11

KPD-90 DN11

KPD-105 DR11

m3/h

600/480/300

1000/853/684

1550/1350/1150

2000/1650/1250

2000/1650/1250

Maximum pressure available

Pa

60

100

100

160

160

Sound pressure (low speed)

dB (A)

27.5

40

40

40

40

mm

975/200/450

1055/210/674

1100/249/774

1360/249/774

1360/249/774

INDOOR UNIT Air flow

Width/Height/Depth Net weight

Kg

18

25.6

31.5

40.6

40.5

Power wiring

mm2

with communication

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires***

mm2

(3+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

KUE-35 DVN11

KUE-52 DVN10

KUE-71 DVN10

Rotary

Rotary

Double rotary

Double rotary

Double rotary

Outdoor airflow

3

m /h

2000

2100

2700

4300

4300

Sound pressure

dB (A)

56

56.5

60.5

59.5

61

R-410A

R-410A

R-410A

R-410A

R-410A

gr

1050 / 15

1780 / 15

1950 / 30

2800 / 30

3200 / 30

AXIAL OUTDOOR UNIT Compressor type

Refrigerant Refrigerant charge / Additional charge**

KUE-90 DVN10 KUE-105 DVN10

mm (Inch)

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Inlet liquid pipe Gas

mm (Inch)

ø9.52 (3/8")

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

Max. piping length

m

25

30

50

50

65

Pipe height difference

m

10

20

25

25

30

Width/Height/Depth

mm

800/554/333

800/554/333

845/702/363

946/810/410

946/810/410

Net weight

Kg

29.9

35.5

49

62.9

67.2

Power wiring (10 m max.)

2

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x4

(2+T)x4

Shielded communication wires***

mm2

(3+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Inlet liquid pipe Liquid

Power supply

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. *** Except for 35 (3.5 kW) models. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

130


Inspiration, Innovation, Evolution

4.0 R-410A

x2

SCOP

50/60

!

Hz

KPD-105 DTN11

KPD-125 DVN10

KPD-125 DTN10

KPD-140 DVN11

KPD-140 DTN11

KPD-160 DTN11

2.40/10.55/12.01

3.22/12.31/13.19

3.22/12.31/13.19

4.1/14.07/16.41

4.1/14.07/16.41

4.98/15.82/18.11

2064/9073/10329

2769/10587/11343

2769/10587/11343

3526/12100/14113

3526/12100/14113

4283/13605/15575

0.66/4.06/4.38

1.07/4.09/5.07

1.07/4.09/5.07

1.37/5.12/6.31

1.37/5.12/6.31

1.66/5.26/6.97

6.1

5.6

5.6

6.1

6.1

6.1

A++

A+

A+

A++

A++

A++

2.78/11.14/13.20

2.93/13.48/14.65

2.93/13.48/14.65

4.34/16.12/18.13

4.34/16.12/18.13

5.28/18.17/20.51

2391/9580/11352

2520/11593/12599

2520/11593/12599

3732/13863/15592

3732/13863/15592

4541/15626/17639

0.65/3.09/4.40

0.98/3.54/5.23

0.98/3.54/5.23

1.45/4.36/6.48

1.45/4.36/6.48

1.76/5.03/7.32

4.0

4.0

4.0

4.0

4.0

4.0

A+

A+

A+

A+

A+

A+

9.29

9.73

9.73

10.79

10.79

10.88

2.56

2.75

2.78

2.77

2.71

2.86

KPD-105 DR11

KPD-125 DN10

KPD-125 DN10

KPD-140 DR11

KPD-140 DR11

KPD-160 DR11

2000/1650/1250

2200/1900/1600

2200/1900/1600

2900/2600/2100

2900/2600/2100

2900/2600/2100

160

160

160

160

160

160

40

44

44

48

48

50.5

1360/249/774

1200/300/865

1200/300/865

1200/300/874

1200/300/874

1200/300/874

40.5

43.4

43.4

47.6

47.6

47.6

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KUE-105 DTN10

KUE-125 DVN10

KUE-125 DTN10

KUE-140 DVN10

KUE-140 DTN10

KUE-160 DTN10

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

4300

4300

4300

6800

6800

7200

62

62.5

63

65

65

62.5

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

3200 / 30

3650 / 30

3650 / 30

4000 / 30

4000 / 30

4300 / 30

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

65

65

65

65

65

30

30

30

30

30

30

946/810/410

946/810/410

946/810/410

952/1333/415

952/1333/415

952/1333/415

78.9

70.5

85

95.1

108.1

112.8

(4+T)x2.5

(2+T)x4

(4+T)x2.5

(2+T)x6

(4+T)x4

(4+T)x6

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

380-400/3/50

220-240/1/50

380-400/3/50

220-240/1/50

380-400/3/50

380-400/3/50

131

ZEN R-410A COMMERCIAL

UNTIL END OF STOCK


R-410A COMMERCIAL RANGE FLOOR STANDING SETS

FLOOR STANDING GENERAL CHARACTERISTICS Kaysun Floor Standing units are available with both axial and centrifugal fans. This improves versatility and the possibility to add more indoor units in every installation.

Built-in controller.

Wireless controller (optional).

Easy integration into the room environment.

Bottom air intake and upper air discharge.

+

BOTTOM AIR INTAKE / UPPER AIR DISCHARGE

UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

CENTRALISED

KCCT-64 I (B)

KID-02 S

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

132

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

R-410A

TECHNICAL SPECIFICATIONS

kW Kcal/h kW

kW

m3/h dB (A) mm Kg mm2 mm2 V / F / Hz

DC

KPV-140 DVN10

KPV-140 DTN10

KPVC-140 DTN10

3.52/14.07/14.95

3.96/14.07/14.95

13.98

3027/12100/12857

3406/12100/12857

12023

0.46/5.00/5.80

0.46/5.00/5.85

5.20

6.1

6.1

-

A++

A++

-

2.43/14.65/16.41

2.43/14.65/17.0

14

2090/12599/14113

2090/12599/14113

12341

0.45/4.44/5.05

0.45/4.44/5.05

4.64

4.0

-

-

A+

A+

-

9.81

9.81

9.75

2.81

2.81

-

KPV-140 DN10

KPD-140 DN10

KPV-140 DN10

2150/1850/1450

2150/1850/1450

2150/1850/1450

44

44

44

600/1934/455

600/1934/455

600/1934/455

61.6

61.6

61.6

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

2x1.5

2x1.5

2x1.5

220-240/1/50

220-240/1/50

220-240/1/50

KUE-140 DVN10

KUE-140 DTN10

KUEC-140 DTN10

Rotary

Double rotary

Scroll

m3 / h / Pa dB (A)

6800

6800

3600 / 60

65

65

64

R-410A

R-410A

R-410A

gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz

4000 / 30

4000 / 30

4000 / 30

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

65

65

65

30

30

30

952/1333/415

952/1333/415

1394/568/783

95.1

108.1

177

(2+T)x6

(4+T)x4

(4+T)x4

AXIAL OUTDOOR UNIT Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Liquid pipe Liquid Liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply

!

2x1.5

2x1.5

2x1.5

220-240/1/50

380-400/3/50

380-400/3/50

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

133

ZEN R-410A COMMERCIAL

kW Kcal/h kW

INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Power wiring Shielded communication wires Power supply

DC

UNTIL END OF STOCK

SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./nom./max.) Heating capacity (min./nom./max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC

x2


Mo

R-410A COMMERCIAL RANGE TWINS

DC INVERTER Motor ventilador Ext. consumo eléctrico

40W

TWINS

TECNOLOGIA

Menos ruido

The balance in the Zen range results in good service and greater comfort for users and installers. Zen Inverter units are fitted with a specific electronic board that allows for connecting two indoor units to the same outdoor unit. TWIN technology can be applied to compact Cassette 600x600, Art Flux 360º SuperSlim Cassette , ducts and Floor/Ceiling units. Furthermore, for the first time, sets of different indoor units can be made; i.e, you can combine, for example, a duct unit with a floor/ceiling type unit, among many other possibilities, provided that both indoor units are the same power.

Twins units represent the versatility and balance of the Zen range, and are presented as an option for commercial spaces that require more than one indoor unit to achieve a suitable air-conditioning without demanding more outdoor units.

In ZEN Twins sets, one can choose from two types of indoor unit. You can create your own Twin set by combining the 2 indoor units that suit you best, provided that they have the same capacity.

+

+

INDOOR UNIT 600x600 cassette SuperSlim cassette Duct FLOOR / CEILING

INDOOR UNIT 600x600 cassette SuperSlim cassette Duct FLOOR / CEILING

+

STANDARD KID-02 S KC-03.1 SPS

Maximum height difference between indoor units of a TWIN system: 0.5 metres Branch pipe not included. Add T-type branch pipe or Kaysun KCMI 112 branch pipe

L

L1

L2

OUTDOOR UNIT (AXIAL OR CENTRIGUAL)

UNIT A

Maximum distance (L+L1+L2)

PIPE DISTANCE

UNIT B

52+52 indoor combination (A+B)

50 m.

71+71 indoor combination (A+B)

65 m.

90+90 indoor combination (A+B)

65 m.

Maximum distance between the branch pipe and the indoor unit (L1 and L2)

15 m.

Maximum difference in length between the branch pipe and the indoor units (L1-L2)

10 m.

Between outdoor unit and indoor units

20 m.

Between indoor units (A and B)

0.5 m.

LEVEL DIFFERENCE

134

Menos vibración

Twins combinations can be arranged with th following power characteristics: - Outdoor unit of 10.5kW with two indoor units of 5.2kW - Outdoor unit of 14.0kW with two indoor units of 7.1kW - Outdoor unit of 16.0kW with two indoor units of 9.0kW

DIFFERENT TYPES OF INDOOR UNIT CAN BE COMBINED

OUTDOOR UNIT

Ro

TRIPLE DC INVERTER

Protección IPX4

Eficiente ≥70%


Inspiration, Innovation, Evolution

AXIAL COMBINED SYSTEMS

R-410A

INDOOR UNIT

x2

OUTDOOR UNIT

ZEN R-410A COMMERCIAL

SETS (600 x 600) RECOMMENDED CONTROL

KCI-52 DN10

KUE-105 DVN10

KID-02 S

KCI-52 DN10

KUE-105 DTN10

KID-02 S

OUTDOOR UNIT

RECOMMENDED CONTROL

SUPERSLIM CASSETTE INDOOR UNIT

x2

KCIS-52 DR11

KUE-105 DVN10

KID-02 S

KCIS-52 DR11

KUE-105 DTN10

KID-02 S KID-02 S

KCIS-71 DR11

KUE-140 DVN10

KCIS-71 DR11

KUE-140 DTN10

KID-02 S

KCIS-90 DN10

KUE-160 DTN10

KID-02 S

OUTDOOR UNIT

RECOMMENDED CONTROL

Ducts

NEW

INDOOR UNIT KPD-52 DR11

x2

KUE-105 DVN10

KC-03.1 SPS

KPD-52 DR11

KUE-105 DTN10

KC-03.1 SPS

KPD-71 DR11

KUE-140 DVN10

KC-03.1 SPS

KPD-71 DR11

KUE-140 DTN10

KC-03.1 SPS

KPD-90 DN11

KUE-160 DTN10

KC-03.1 SPS

OUTDOOR UNIT

RECOMMENDED CONTROL

FLOOR / CEILING INDOOR UNIT

x2

KPC-52 DR11

KUE-105 DVN10

KID-02 S

KPC-52 DR11

KUE-105 DTN10

KID-02 S

KPC-71 DR11

KUE-140 DVN10

KID-02 S

KPC-71 DR11

KUE-140 DTN10

KID-02 S

KPC-90 DN10

KUE-160 DTN10

KID-02 S

R-410A

CENTRIFUGAL COMBINED SYSTEMS SUPERSLIM CASSETTE INDOOR UNIT

x2

OUTDOOR UNIT

RECOMMENDED CONTROL

KCIS-71 DR11

KUEC-140 DTN10

KID-02S

KCIS-90 DN10

KUEC-160 DTN10

KID-02 S

Ducts

NEW

INDOOR UNIT

OUTDOOR UNIT

RECOMMENDED CONTROL

KPD-71 DR11

KUEC-140 DTN10

KC-03.1 SPS

KPD-90 DN11

KUEC-160 DTN10

KC-03.1 SPS

x2

FLOOR / CEILING INDOOR UNIT

OUTDOOR UNIT

RECOMMENDED CONTROL

KPC-71 DR11

KUEC-140 DTN10

KID-02 S

KPC-90 DN10

KUEC-160 DTN10

KID-02 S

x2

135


R-410A COMMERCIAL RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

SANGULÍ BUENAVISTA CONFERENCE CENTRE CAMPINGCENTRE RESORT BUSINESS Location:Oviedo Cambrils (Tarragona) Location: Initialsituation: situation:New Renovation Initial construction Units Unitsinstalled: installed:Zen ZenInverter Axial Capacity: Capacity: 140 1000kW kW

THE ZEN RANGE FOR COMMERCIAL APPLICATIONS OFFERS MULTIPLE INSTALLATION POSSIBILITIES THAT ARE HIGHLY ENERGYEFFICIENT AND ENVIRONMENTALLYFRIENDLY. ITEMS IN THE ZEN AXIAL RANGE EQUIPPED WITH AN OUTDOOR AXIAL UNIT ARE THE MOST COMPACT SOLUTION FOR ITS INSTALLATION.

OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN ZEN HOTELS, PUBLIC BUILDINGS HOSPITALS, HEALTH CLINICS AND CENTRES Autism Association of Jeréz (Cádiz), Joan XXIII Hospital (Tarragona), Salamanca Hospital (Salamanca), Sagrado Corazón Health Clinic (Madrid), Museum of Oil (Jaén), Depentya Foundation (Seville), Nuevo Arcangel Football Stadium (Córdoba)

136

PRIVATE RESIDENCES Residential Complex (Vera), Alpe Property Developments (Tortosa), 134 private residences in East Seville (Seville), Mercainmo Property Developments (Lleida), Residential Complex (Marbella), 503 private residences in Bekinsa Residential Complex (Seville), Las Brisas Hotel (Llanes)

BUSINESS CENTRES AND OFFICES Navarrete Offices (La Rioja), Eder Epele offices (Guipúzcoa), Greg Business Centre (Barcelona), Trade Fair (Valladolid), Electric Rooms- Asturiana del Zinz S.A.U. (Asturias), Galvanizados Avilés offices (Avilés), Retevisión Valladolid (Valladolid), Eiffage Energy offices (Ávila), Acofarma offices (Terrassa), Jordi Verna offices (Granollers),

Banca March offices (Mallorca), Carrefour offices (Málaga), Barceló Market (Madrid), Day SWRO Desalination offices (Marruecos), Caja Rural Zamora bank offices (Zamora) RESTAURANTS 100 Montaditos Brewery (Córdoba), Vermut Rofes Restaurants (Reus), La Sureña Brewery (Córdoba), WOK Restaurant (Cáceres)

COMMERCIAL BUILDING Unity Skates shop (Zaragoza), Lecrerc Mall (Málaga), Confecciones Rubio clothes shop (Cádiz, Seville and Córdoba), Aurgi (Madrid), Toyota authorised dealer (Oviedo), Stradivarius (Manresa), Vitaldent dental clinic (different locations), Lacoste (Vilagarcía de Arousa), Lowfit Gym (Seville), Basic Fit Gym (Madrid) , Alimerka Supermarkets (León)


Inspiration, Innovation, Evolution

VALLADOLID TRADE FAIR

HOSPITALS

CONFERENCE CENTRES

ZEN R-410A COMMERCIAL

HOSPITAL DE SALAMANCA

Location: Salamanca Units installed: Zen Axial Capacity: 100 kW

Location: Valladolid Units installed: Zen Axial Capacity: 110 kW

ROMAN THEATRE OF MERIDA HISTORIC BUILDING

CERVECERIA LA SUREÑA

Location: Mérida Units installed: Centrifugal Zen Capacity: 32 kW

Location: Córdoba Units installed: Centrifugal Zen Capacity: 50 kW

RESTAURANT

STRADIVARIUS

AMD DECOLLETAGE

FASHION STORES

AUTOMOTIVE COMPONENTS FACTORY

Location: Manresa Units installed: Centrifugal Zen Capacity: 30 kW

Location: Marnaz (France) Units installed: KPD 90 DVN10 Capacity: 10.55 kW

137


ZEN ZEN R-32 COMMERCIAL RANGE

INTRODUCTION TO THE PRODUCT RANGE....................................... ..140 SETS........................................................................................................ ..142 SUPERSLIM CASSETTE.................................................................... ..144 FLOOR / CEILING.............................................................................. ..146 DUCTS ............................................................................................... ..148


ZEN R-32 COMMERCIAL

ZEN

ZEN R-32 COMMERCIAL RANGE


ZEN R-32 COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

ZEN

“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”

R-32 COMMERCIAL RANGE

Introducing our commercial range units using R-32 refrigerant. The main characteristics of this range we wish to highlight are its advanced technology, its efficiency, its versatility and its performance. Combinations made with axial outdoor units are fitted with Inverter technology, thereby optimising energy efficiency and seasonal performance indicators. The outdoor units of this type have an

R-32 REFRIGERANT UNITS

aesthetic with a robust design and good sound performance. It could be said that the controls of this range are at the expected height. The KID-02 S, a wireless smart control that can inspect the operation of units and change configuration parameters. Regarding wired controllers, we offer the KC-03.1 SPS controller, which is able to adjust the static pressure of the Ducts Unit. Furthermore, it should be pointed out that this year some models in this range will have optional Wi-Fi control.

NEW

Last year, Frigicoll, by means of its KAYSUN brand, started marketing some of its products fitted with R-32 refrigerant. The new EU regulations encourages the use of alternative gases, such as R-32 refrigerant gas. The R-32 has a 675 global warming potential (GWP), a very low rate if compared to the 2,088 GWP produced by R-410A refrigerant. It is more cost-efficient, 10 % more suitable and reduces charge volume by 25% because it is more compact. In addition, it offers better performance at an extreme outdoor temperature and is easy to reuse and recycle, as it is made up of a single refrigerant component.

+ + +

STRONGER AND COMPACT

PERFORMANCE

ENERGY SAVING

SOUND LEVEL

SMART CONTROLLERS Kaysun’s ZEN series has a top range of controllers. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.

KC-03.1 SPS

140

KID-02 S

+

WEEKLY TIMER

+

INSTALLATION PARAMETRES MODIFICATION

+

DUCT UNIT’S STATIC PRESSURE ADJUSTMENT

+

OPERATION PARAMETERS CHECKING

+

FOLLOW ME

+

FOLLOW ME


Inspiration, Innovation, Evolution

DUCT UNIT

NEW

• Removable filter (it can be extracted without touching the unit). • Flange for fitting the outlet duct. • Flange for fitting the intlet (return) duct. • Double return system possibility rear or lower inlet. • Condensation pump. • Pre-installation for fresh air inlet.

• Electric box removable up to 1 metre apart from the unit's body. • Voltage-free Alarm and ON/OFF dry contacts. • The KC-03.1 SPS controller allows adjusting the available pressure automatically. • Up to 160 Pa available depending on the model. • Horizontal and vertical installation. • Reduced height unit.

Compatible with

TWO COMMUNICATION WIRES

x2

The ZEN R-32 range units only require two shielded wires without polarity to carry out the operation. This new characteristic makes the communication wiring works cheaper and easier.

K03 WIFI LCAC

NEW

has an optional WiFi adapter for some of its indoor unit models in the ZEN range. This accessory connects the unit to our domestic WiFi network and controls it through an App installed on our Smartphone. The application also includes a weekly timer built into the App to ease and improve the control function of our air-conditioning system.

S1 S2

S1 S2

141

ZEN R-32 COMMERCIAL

With regard to the semi-industrial indoor units of the ZEN RANGE, we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:


ZEN R-32 COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

CASSETTE R-32

142


Inspiration, Innovation, Evolution

POWER kW

3.5

5.2

7.1

9.0

10.5

12.5

14.0

16.0

SETS R-32 NEW

SUPERSLIM CASSETTE

KCIS-105 DVR11 KCIS-105 DTR11

KCIS-140 DTR11

KCIS-160 DTR11

KPC-71 DVR11

KPC-105 DVR11 KPC-105 DTR11

KPC-140 DTR11

KPC-160 DTR11

KPD-71 DVR11

KPD-105 DVR11 KPD-105 DTR11

KPD-140 DTR11

KPD-160 DTR11

KCIS-71 DVR11

ZEN R-32 COMMERCIAL

KCIS-52 DVR11

(Page 144)

R-32 NEW

FLOOR / CEILING KPC-52 DVR11

(Page 146)

NEW

Ducts

(Page 148) KPD-52 DVR11

143


ZEN R-32 COMMERCIAL RANGE SUPERSLIM CASSETTE TYPE SETS

SUPERSLIM CASSETTE

R-32 NEW

GENERAL CHARACTERISTICS In order to provide users with maximum comfort, the cassette units are fitted with a 360° air diffusion system that allows them to reach every corner of the room. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings. •

Pre-installed inlet for fresh air.

Voltage-free alarm and ON/OFF dry contacts.

Standard condensation pump.

360º airflow.

Louvres position storage.

Prepared for side ducts (closing air outlets).

Slim design compact unit.

+

STANDARD CONDENSATION PUMP

KID-02 S (*) RECOMMENDED

NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the € price for the set, the price difference between the recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range

INDIVIDUAL

CENTRALISED

KID-02 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

K01-KNX

K01-WIFI

BMS AND SOFTWARE

K01-LON

144

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL


Inspiration, Innovation, Evolution

4.0

DC

x2

SCOP

R-32

50/60

!

Hz

DC

TECHNICAL CHARACTERISTICS SET kW

1.26/5.28/6.15

2.23/7.03/8.21

2.64/10.55/12.02

2.64/10.55/12.02

4.76/14.0/14.58

5.28/15.8/16.71

Kcal/h

1085/4540/5289

1917/6045/7061

2270/9073/10335

2270/9073/10337

3430/12040/12540

4540/13585/14340

kW

0.28/1.64/2.15

0.48/2.19/2.85

0.66/3.75/4.5

0.66/3.95/4.5

1.17/5.13/5.6

1.14/5.95/6.68

6.1

6.1

6.1

6.1

6.1

6.1

A++

A++

A++

A++

A++

A++

kW

1.76/5.57/7.03

2.43/7.62/8.65

2.93/11.14/13.19

2.93/11.14/13.19

3.93/16.1/16.77

4.4/18.2/19.34

Kcal/h

1515/4790/6046

2090/6550/7439

2520/9580/11343

2519/9580/11343

3600/13840/14420

3785/15650/16630

kW

0.33/1.5/2.18

0.5/2.05/2.88

0.65/2.96/4.55

0.65/2.96/4.55

0.98/5.05/5.38

1.02/6.03/6.45

SCOP

4.0

4.0

4.0

4.0

4.0

4.0

Heating efficiency class

A+

A+

A+

A+

A+

A+

SEER Cooling energy class Heating capacity (min./rated/max.) Heating capacity (min./rated/max.) Heat input capacity (min./rated/max.)

INDOOR UNIT

KCIS-52 DR11

KCIS-71 DR11

KCIS-105 DR11

Indoor airflow

m3/h

1036/867/763

1378/1200/1032

1775/1620/1438

KCIS-105 DR11 KCIS-140 DR11 KCIS-160 DR11 1775/1620/1438

1715/1568/1381

1970/1737/1537

Sound pressure (Low speed)

dB (A)

37

40

46

46

49

48

Width/Height/Depth

mm

840/205/840

840/205/840

840/245/840

840/245/840

840/287/840

840/287/840

Net weight

Kg

21.3

23

27.5

27.5

29

29.7

Width/Height/Depth (panel)

mm

950/55/950

950/55/950

950/55/950

950/55/950

950/55/950

950/55/950

Kg

5

5

5

5

5

5

Power wiring

Net weight (panel)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

OUTDOOR UNIT

KUE-52 DVR11

Compressor type

KUE-71 DVR11 KUE-105 DVR11 KUE-105 DTR11 KUE-140 DTR11 KUE-160 DTR11

Rotary

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

Outdoor airflow

m3/h

2100

2700

4000

4000

7500

7500

Sound pressure

dB (A)

57

62

65

65

66

66

R-32

R-32

R-32

R-32

R-32

R-32

gr

1350 / 12

1500 / 24

2400 / 24

2400 / 24

2800 / 24

2950 / 24

Liquid pipe Liquid

mm (inch")

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Liquid pipe Gas

mm (inch")

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

Max. piping length

m

30

50

65

65

65

65

Pipe height difference

m

20

25

30

30

30

30

Width/Height/Depth

mm

800/554/333

845/702/363

946/810/410

946/810/410

952/1333/415

952/1333/415

Refrigerant Refrigerant charge / Additional charge**

Kg

35.5

66.8

66.8

81.5

106.7

111.3

Power wiring (10 m max.)

Net weight

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x4

(4+T)x2.5

(4+T)x4

(4+T)x6

Shielded communication wires

mm2

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

380-400/3/50

380-400/3/50

380-400/3/50

Power supply

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

145

ZEN R-32 COMMERCIAL

Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./ rated/max.)

KCIS-52 DVR11 KCIS-71 DVR11 KCIS-105 DVR11 KCIS-105 DTR11 KCIS-140 DTR11 KCIS-160 DTR11


ZEN R-32 COMMERCIAL RANGE FLOOR / CEILING SETS

FLOOR / CEILING

R-32 NEW

GENERAL CHARACTERISTICS

Kaysun Zen range makes air conditioning at your disposal through its most versatile product, the Floor/Ceiling units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit. •

Easy access to components for maintenance.

Improved airflow for a greater comfort.

FLOOR or CEILING installation.

Voltage-free alarm and ON/OFF dry contacts.

New numerical display in the receiver.

On/Off and Alarm dry contacts.

+

CEILING/FLOOR COMPATIBLE

+

VOLTAGE FREE CONTACTS + ALARM

KID-02 S (*) RECOMMENDED

NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the € price for the set, the price difference between the recommended controller and the selected controller.

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

KID-02 S

CENTRALISED

KC-03.1 SPS

KC-03 SPS

KC-02.1 H

KC-01 S

KCT-02.1 SR

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

146

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

4.0 SCOP

R-32

x2

50/60 Hz

!

TECHNICAL CHARACTERISTICS

Cooling capacity (min./ rated/max.) Cooling capacity (min./ rated/max.) Cold input capacity (min./rated/max.)

KPC-52 DVR11 kW

1.29/5.28/6.15

2.20/7.03/8.21

2.64/10.55/12.02

2.64/10.55/12.02

Kcal/h

1110/4540/5290

1891/6046/7061

2270/9073/10337

2270/9073/10337

kW

0.28/1.64/2.15

0.48/2.19/2.85

0.66/3.75/4.5

0.66/3.95/4.5

1.16/5.5/5.7

1.23/6.06/6.29

6.1

6.1

6.1

6.1

6.1

6.1

A++

A++

A++

A++

A++

A++

kW

1.76/5.57/7.03

2.43/7.62/8.65

2.93/11.14/13.19

2.93/11.14/13.19

3.81/16.1/18.07

4.4/18.2/19.64

Kcal/h

1513/4790/6046

2090/6550/7439

2520/9575/11343

2520/9575/11343

kW

0.33/1.5/2.18

0.5/2.05/2.88

0.65/2.96/4.5

0.65/3.0/4.55

1.02/5.05/6.2

1.02/6.03/6.54

SCOP

4.0

4.0

4.0

4.0

4.0

4.0

Heating efficiency class

A+

A+

A+

A+

A+

A+

SEER Cooling energy class Heating capacity (min./ rated/max.) Heating capacity (min./ rated/max.) Heat input capacity (min./rated/max.)

INDOOR UNIT Indoor airflow Sound pressure (Low speed) Width/height/depth (ceiling installation) Net weight

KPC-71 DVR11 KPC-105 DVR11 KPC-105 DTR11 KPC-140 DTR11 KPC-160 DTR11 4.96/14.2/15.11

5.28/16.0/17.0

4265/12210/12990 4540/13760/14620

3275/13845/15540 3785/15650/16890

KPC-52 DR11

KPC-71 DR11

KPC-105 DR11

KPC-105 DR11

KPC-140 DR11

KPC-160 DR11

m3/h

900/780/675

1200/1060/850

2160/1845/1430

2160/1844/1430

2330/1930/1415

2450/1830/1430

dB (A)

37

41

42

42

46

42

mm

1068/235/675

1068/235/675

1650/235/675

1650/235/675

1650/235/675

1650/235/675

Kg

26.6

26.8

39

39

46

41.4

Power wiring

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

OUTDOOR UNIT

KUE-52 DVR11

Compressor type

KUE-71 DVR11 KUE-105 DVR11 KUE-105 DTR11 KUE-140 DTR11 KUE-160 DTR11

Rotary

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

Outdoor airflow

m3/h

2100

2700

4000

4000

7500

7500

Sound pressure

dB (A)

57

62

65

65

66

66

R-32

R-32

R-32

R-32

R-32

R-32

gr

1350 / 12

1500 / 24

2400 / 24

2400 / 24

2800 / 24

2950 / 24

Inlet liquid pipe Liquid

mm (inch")

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Inlet liquid pipe Gas

mm (inch")

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

Max. piping length

m

30

50

65

65

65

65

Pipe height difference

m

20

25

30

30

30

30

Width/Height/Depth

mm

800/554/333

845/702/363

946/810/410

946/810/410

952/1333/415

952/1333/415

Net weight

Kg

35.5

66.8

66.8

81.5

106.7

111.3

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x4

(4+T)x2.5

(4+T)x4

(4+T)x6

mm2

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

380-400/3/50

380-400/3/50

380-400/3/50

Refrigerant Refrigerant charge / Additional charge**

Power wiring (10 m max.) Shielded communication wires Power supply

2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

147

ZEN R-32 COMMERCIAL

SET


ZEN R-32 COMMERCIAL RANGE DUCTS SETS

Ducts

NEW

GENERAL CHARACTERISTICS

Kaysun ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design. • Easily removable filter.

• Electric box removable up to 1 metre apart from the unit's body.

• Flanges in the inlet and outlet mouths.

• Up to 160 Pa available depending on the model.

• Possibility for double air intake (rear or lower intake). • Fresh air intake at a side of the unit.

• The KC-03.1 SPS controller allows adjusting the available pressure automatically.

• Voltage-free alarm and ON/OFF dry contacts.

• Horizontal and vertical installation.

• Standard condensation pump of up to 750 mm in height.

• Reduced height unit.

+

VERTICAL INSTALLATION (OPTIONAL)

+

STANDARD CONDENSATION PUMP up to 750 mm HEIGHT

Compatible with

NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY

KC-03.1 SPS PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the € price for the set, the price difference between the recommended controller and the selected controller.

(*) RECOMMENDED

SINGLE

For further information, please see our Controllers Range

INDIVIDUAL

KID-02 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KC-03.1 SPS

KC-03 SPS

KC-02.1 H

KC-01 S

KCT-02.1 SR

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

148

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI


Inspiration, Innovation, Evolution

4.0 R-32

x2

SCOP

50/60 Hz

!

TECHNICAL CHARACTERISTICS

Cooling capacity (min./ rated/max.) Cooling capacity (min./ rated/max.) Cold input capacity (min./rated/max.)

KPD-52 DVR11

KPD-71 DVR11 KPD-105 DVR11 KPD-105 DTR11 KPD-140 DTR11 KPD-160 DTR11

kW

1.23/5.28/6.15

2.2/7.03/8.21

2.93/10.55/12.02

2.93/10.55/12.02

4.1/14.07/16.41

4.98/15.82/18.11

Kcal/h

679/4541/5289

1032/6046/7061

2520/9073/10337

2520/9073/10337

3526/12100/14113

4283/13605/15575

KW

0.28/1.64/2.15

0.48/2.19/2.85

0.98/3.97/4.62

0.98/3.97/4.62

1.37/5.12/6.31

1.66/5.26/6.97

6.1

6.1

6.3

6.1

6.1

6.1

A++

A++

A++

A++

A++

A++

KW

1.76/5.57/7.03

2.43/7.62/8.65

2.64/11.13/13.19

2.64/11.13/13.19

4.34/16.12/18.13

5.28/18.17/20.51

Kcal/h

757/4876/6046

1032/6046/7439

2270/9575/11343

2270/9575/11343

3732/13863/15592

4541/15626/17639

KW

0.5/2.05/2.88

0.5/2.05/2.88

0.88/2.92/4.69

0.88/2.92/4.69

1.45/4.36/6.48

1.76/5.03/7.32

SCOP

4.0

4.0

4.0

4.0

4.0

4.0

Heating efficiency class

A+

A+

A+

A+

A+

A+

SEER Heating energy class Heating capacity (min./ rated/max.) Heating capacity (min./ rated/max.) Heat input capacity (min./rated/max.)

INDOOR UNIT

KPD-52 DR11

KPD-71 DR11

KPD-105 DR11

KPD-105 DR11

KPD-140 DR11

KPD-160 DR11

3

m /h

1000/853/684

1550/1350/1150

2000/1650/1250

2000/1650/1250

2900/2600/2100

2900/2600/2100

Pa

100

160

160

160

160

160

dB (A)

40

40

40

40

48

50.5

Width/Height/Depth

mm

1055/210/674

1100/249/774

1360/249/774

1360/249/774

1200/300/874

1200/300/874

Net weight

Kg

25.6

31.5

40.5

40.5

47.6

47.6

Air flow Maximum pressure available Sound pressure (low speed)

Power wiring

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires***

mm

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

2 2

OUTDOOR UNIT

KUE-52 DVR11

Compressor type Outdoor airflow

m3/h

Sound pressure

dB (A)

Refrigerant

KUE-71 DVR11 KUE-105 DVR11 KUE-105 DTR11 KUE-140 DTR11 KUE-160 DTR11

Rotary

Double rotary

Double rotary

Double rotary

Double rotary

Double rotary

2100

2700

4000

4000

7500

7500

57

62

65

65

66

66

R-32

R-32

R-32

R-32

R-32

R-32

Refrigerant charge / Additional charge** Diameter of cooling line Liquid

gr

1350 / 12

1500 / 24

2400 / 24

2400 / 24

2800 / 24

2950 / 24

mm (Inch)

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Inlet liquid pipe Gas

mm (Inch)

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

Max. piping length

m

30

50

65

65

65

65

Pipe height difference

m

20

25

30

30

30

30

Width/Height/Depth

mm

800/554/333

845/702/363

946/810/410

946/810/410

952/1333/415

952/1333/415

Net weight

Kg

35.5

66.8

66.8

81.5

106.7

111.3

mm

(2+T)x2.5

(2+T)x2.5

(2+T)x4

(4+T)x2.5

(4+T)x4

(4+T)x6

mm2

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

2x1.5

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

380-400/3/50

380-400/3/50

380-400/3/50

Power wiring (10 m max.) Shielded communication wires Power supply

2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)

149

ZEN R-32 COMMERCIAL

SET


ZEN HIGH CAPACITY COMMERCIAL RANGE

INTRODUCTION TO THE PRODUCT RANGE....................................... ..152 HIGH-CAPACITY DUCT SETS................................................................ ..153 AIR CONDENSED - FRONT DISCHARGE.......................................... ..154 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN3................. ..156 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN4 S.............. ..158 WATER CONDENSED....................................................................... ..160 STATIC PRESSURE GRAPHS............................................................ ..162

KEY INSTALLATIONS........................................................................... ..164


HIGH CAPACITY COMMERCIAL RANGE

ZEN ZEN ZEN HIGH CAPACITY CAPACITY HIGH COMMERCIAL COMMERCIAL


HIGH CAPACITY COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

ZEN

HIGH CAPACITY COMMERCIAL RANGE

We present the high-capacity commercial range. The main characteristics we wish to highlight in this range are its vast cooling power and large air flows. These machines are ideal for climate control in large spaces. Most of these combinations are equipment with a compressor, outdoor ventilators and indoor ventilators with DC Inverter technology, resulting in efficiency and energy savings.

“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT” Basically, we have 6 power levels of indoor units that rangefrom 20 to 56 kW, and which can be combined with different types of the outdoor unit: front discharge, vertical discharge and water condensation.

OUTDOOR UNITS The high-capacity commercial range contains four different types of outdoor unit, ensuring perfect adaptability to each different type of installation:

FRONT AIR DISCHARGE

VERTICAL AIR DISCHARGE

R-410A LITTLE INSTALLATION SPACE

TWIN ROTARY COMPRESSORS

R-410A WHILE STOCKS LAST STATIC PRESSURE AVAILABLE 40 PA UP TO 200 METRES IN LENGTH FOR PIPELINES

CONDENSED BY WATER NEW

R-410A

152

R-410A

FULL DC INVERTER

EXTREMELY COMPACT

STATIC PRESSURE AVAILABLE 60 PA

INDOOR INSTALLATION

UP TO 200 METRES IN LENGTH FOR PIPELINES


Inspiration, Innovation, Evolution

HIGH AIRFLOWS Duct units in the high-capacity commercial rangeare made up of indoor units of ducts with large airflows at high static pressure levels.

STATIC PRESSURE OF UP TO 200 PA

CASSETTE POWER kW

20.0

25.0

28.0

40.0

45.0

56.0

AIR CONDENSED FRONT AIR DISCHARGE (Page 154) KPDHF-200F DN2

KPDHF-250F DN2

KPDHF-280F DN2

VERTICAL DISCHARGE DN3 (Page 156)

KPDHF-400F DN3

WHILE STOCKS LAST

KPDHF-280V DN3

VERTICAL DISCHARGE DN4 S (Page 158)

KPDHF-400V DN3

KPDHF-450V DN3

KPDHF-560 DN3

KPDHF-400V DN4 S

KPDHF-450V DN4 S

KPDHF-560V DN4 S

NEW

KPDHF-280V DN4 S

WATER CONDENSED

KPDHF-450F DN3

(Page 160)

KPDHF-250W DN3

KPDHF-280W DN3

KPDHF-560W DN3

153

ZEN HIGH CAPACITY COMMERCIAL

HIGH AIRFLOWS


HIGH CAPACITY COMMERCIAL RANGE AIR CONDENSED

HIGH CAPACITY DUCTS AIR CONDENSED - FRONT DISCHARGE TECHNICAL SPECIFICATIONS SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input

KPDHF-200F DN2

KPDHF-250F DN2

KPDHF-280F DN2

KPDHF-400F DN3

KPDHF-450F DN3

kW

10.0/20.0/21.1

13.0/25.0/27.5

13.0/26.1/27.5

20.0/40.0/42.3

22.5/45.0/47.6

Kcal/h

8600/17200/18146

11180/21500/23650

11180/22446/23650

17200/34400/ 36378

19350/38700/40936

W

7610

9015

9110

14300

16300

kW

11.0/22.0/26.1

14.3/27.0/33.7

14.3/28.5/33.7

22.5/45.0/53.3

25.0/50.0/59.2

19350/38700/ 45838

21500/43000/50912

13800

15400

Kcal/h 9460/18920/22446 12298/23220/28982 12298/24510/28982 W

INDOOR UNIT

7610

8255

8310

KPDHF-200 DN3.0

KPDHF-250 DN3.0

KPDHF-280 DN3.0

KPDHF-400 DN2.4

KPDHF-450 DN2.4

m3/h

4800/3900/3500

4600/4000/3600

4600/4000/3600

7700/6400/5200

7700/6400/5200

Maximum pressure available

Pa

200

200

200

200

200

Sound pressure (low speed)

dB (A)

50

50

50

56

56

mm

1443/470/810

1443/470/810

1443/470/810

1970/668/903

1970/668/903

Air flow

Width/Height/Depth Net weight Power wiring Communication wiring . Power supply

Kg

108

108

108

232

232

mm2

(2+T)x4

(2+T)x4

(2+T)x4

(2+T)x4

(2+T)x4

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

KMF-200 DN2

KMF-260 DN2

KMF-260 DN2

KMF-400 DN3

KMF-450 DN3

OUTDOOR UNIT Compressor type

Double rotary

Double rotary

Double rotary

Double rotary (2)

Double rotary (2)

m3/h

10999

10494

10494

16575

16575

Static Pressure

Pa

No

No

No

No

No

Sound pressure

dB (A)

59

60

60

62

62

R-410A

R-410A

R-410A

R-410A

R-410A

Outdoor airflow

Refrigerant Refrigerant volume

gr

4800

6200

6200

9000

12000

Inlet liquid pipe Liquid*

mm (inch)

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø12.7 (1/2”)

ø12.7 (1/2”)

Inlet liquid pipe Gas*

mm (inch)

ø19.1 (3/4")

ø22.2 (7/8")

ø22.2 (7/8")

ø25.4 (1")

ø25.4 (1")

m

60

60

60

120

120

Max. piping length Pipe height difference

m

30

30

30

30

30

Width/Height/Depth

mm

1120/1558/528

1120/1558/528

1120/1558/528

1360/1650/540

1460/1650/540

Net weight Power wiring (Max. 10 m) Communication wiring . Power supply

Kg

137

147

147

240

275

mm2

(4+T)x4

(4+T)x4

(4+T)x4

(4+T)x16

(4+T)x16

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

380-415/3/50

380-415/3/50

380-415/3/50

380-415/3/50

380-415/3/50

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 45 metres, please check diameter with our Technical Department. KMF-200/260 working rate: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating) KMF-400/450 working rate: -15ºC to 48ºC (Cooling) / -15ºC to 24ºC (Heating)

154


Inspiration, Innovation, Evolution

R-410A

DC

DC

INVERTER

GENERAL CHARACTERISTICS

Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •

Indoor unit internal expansion system.

220 V ALARM OUTPUT.

Available pressure up to 200 Pa.

Voltage-free ON/OFF dry contact.

Smaller units, 200, 250 and 280 have inverter indoor fan motor.

TEMPERATURE ADJUSTMENT / GREATER COMFORT

+

VOLTAGE-FREE CONTACTS

ZEN HIGH CAPACITY COMMERCIAL

+

KCT-02.1 SR (*) RECOMMENDED

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

KI-02.3 S

CENTRALISED

KCT-02.1 SR

KC-01 S

KC-02.1 H

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

K01-KNX

K01-WIFI

KAYNET CONTROL

155


HIGH CAPACITY COMMERCIAL RANGE AIR CONDENSED

HIGH CAPACITY DUCTS

AIR CONDENSED - VERTICAL DISCHARGE DN3

TECHNICAL SPECIFICATIONS

UNTIL END OF STOCK

KPDHF-280V DN3

SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input

KPDHF-400V DN3 KPDHF-450V DN3 KPDHF-560V DN3

kW

14.0/28.0/29.6

20.0/40.0/42.3

22.5/45.0/47.6

28.0/56.0/59.2

Kcal/h

12040/24080/25456

17200/34400/36378

19350/38700/40936

24080/48160/50912

W

8000

15000

16710

20400

kW

15.8/31.5/37.3

22.5/45.0/53.3

25.0/50.0/59.2

31.5/63.0/74.6

Kcal/h

13588/27090/32078

19350/38700/45838

21500/43000/50912

27090/54180/64156

W

8400

13890

15480

19400

KPDHF-280 DN3.0

KPDHF-400 DN2.4

KPDHF-450 DN2.4

KPDHF-560 DN2.4

m3/h

4600/4000/3600

7700/6400/5200

7700/6400/5200

10100/8400/7000

Maximum pressure available

Pa

200

200

200

200

Sound pressure (low speed)

dB (A)

50

56

56

57

mm

1443/470/810

1970/668/903

1970/668/903

1970/668/903

INDOOR UNIT Air flow

Width/Height/Depth Net weight

Kg

108

232

232

235

Power wiring

mm2

(2+T)x4

(2+T)x4

(2+T)x4

(2+T)x4

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

K2UF-280 DN3

K2UF-400 DN3

K2UF-450 DN3

K2UF-560 DN3

Scroll Inv.

Scroll Inverter + Fixed Scroll (2)

Scroll Inverter + Fixed Scroll (2)

Scroll Inverter + Fixed Scroll (2)

m3/h

11000

15000

15000

18000

Static Pressure

Pa

40

40

40

40

Sound pressure

dB (A)

57

60

60

62

OUTDOOR UNIT Compressor type Outdoor airflow

Refrigerant

R-410A

R-410A

R-410A

R-410A

gr

10000

15000

15000

17000

Inlet liquid pipe Liquid*

mm (inch)

ø12.7 (1/2”)

ø12.7 (1/2”)

ø12.7 (1/2”)

ø15.9 (5/8")

Gas pipeline diameter*

mm (inch)

ø25.4 (1")

ø28.6 (1 1/8")

ø28.6 (1 1/8")

ø28.6 (1 1/8")

Max. piping length

m

150

175

175

200

Pipe height difference

m

70

70

70

110

Width/Height/Depth

mm

960/1615/765

1250/1615/765

1250/1615/765

1390/1615/765

Net weight

Kg

245

325

325

360

(4+T)x6

(4+T)x10

(4+T)x10

(4+T)x16

Refrigerant volume

Power wiring (10 m max.)

mm

Flared communication wires

mm

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

380-415/3/50

380-415/3/50

380-415/3/50

380-415/3/50

Power supply

2 2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 90 metres, please check diameter with our Technical Department. K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)

156


Inspiration, Innovation, Evolution

R-410A

DC

DC

INVERTER

GENERAL CHARACTERISTICS

Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •

Indoor unit internal expansion system.

Voltage-free ON/OFF dry contact.

Available pressure up to 200 Pa.

220 V ALARM OUTPUT.

Indoor unit 280 with Inverter fan.

TEMPERATURE ADJUSTMENT / GREATER COMFORT

+

VOLTAGE-FREE CONTACTS

ZEN HIGH CAPACITY COMMERCIAL

+

KCT-02.1 SR (*) RECOMMENDED

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

KI-02.3 S

CENTRALISED

KCT-02.1 SR

KC-01 S

KC-02.1 H

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

K01-KNX

K01-WIFI

KAYNET CONTROL

157


HIGH CAPACITY COMMERCIAL RANGE AIR CONDENSED NEW

HIGH CAPACITY DUCTS AIR CONDENSED - VERTICAL DISCHARGE DN4 S TECHNICAL SPECIFICATIONS KPDHF-280V DN4 S

KPDHF-400V DN4 S

KPDHF-450V DN4 S

KPDHF-560V DN4 S

kW

14.1/28.0/30.2

20.2/40.0/43.1

22.7/45.0/48.5

28.3/56.0/60.4

Kcal/h

12125/24075/25970

17370/34400/37060

19520/38695/41705

24335/48150/51935

W

7470

13700

15600

19400

kW

14.04/28.0/36.34

20.06/40.0/51.92

22.57/45.0/58.41

28.02/56.0/72.69

Kcal/h

12070/24075/31250

17250/38700/44650

19410/38700/50225

24100/48150/62500

W

6290

12000

13400

17200

SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input

KPDHF-280 DN3

INDOOR UNIT Air flow

KPDHF-400 DN2.4 KPDHF-450 DN2.4 KPDHF-560 DN2.4

3

m /h

4600/4000/3600

7700/6400/5200

7700/6400/5200

10100/8400/7000

Maximum pressure available

Pa

200

200

200

200

Sound pressure (low speed)

dB (A)

50

56

56

57

Width/Height/Depth

mm

443/470/810

1970/668/903

1970/668/903

1970/668/903

Net weight

Kg

108

232

232

235

(2+T)x4

(2+T)x4

(2+T)x4

Power wiring

mm

(2+T)x4

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

OUTDOOR UNIT

K2UF-280 DN4 S

K2UF-400 DN4 S

K2UF-450 DN4 S

K2UF-560 DN4 S

Compressor type

DC Inverter

DC Inverter

DC Inverter

DC Inverter

m3/h

11000

13000

13000

17000

Static Pressure

Pa

60

60

60

60

Sound pressure

dB (A)

58

62

65

66

Power supply

Outdoor airflow

2

Refrigerant

R-410A

R-410A

R-410A

R-410A

gr

11000

13000

13000

17000

Inlet liquid pipe Liquid*

mm (inch)

ø12.7 (1/2")

ø12.7 (1/2")

ø12.7 (1/2")

ø12.7 (1/2")

Gas pipeline diameter*

mm (inch)

ø25.4 (1")

ø28.6 (1 1/8”)

ø28.6 (1 1/8")

ø28.6 (1 1/8")

Max. piping length

m

175

175

175

175

Pipe height difference

m

90

90

90

70

Width/Height/Depth

mm

1090/1805/860

1340/1635/850

1340/1635/850

1340/1635/825

Net weight

Kg

227

277

277

344

(4+T)x6

(4+T)x10

(4+T)x10

(4+T)x16

Refrigerant volume

Power wiring (10 m max.)

mm

Flared communication wires

mm

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

380-415/3/50

380-415/3/50

380-415/3/50

380-415/3/50

Power supply

2 2

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 90 metres, please check diameter with our Technical Department. K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)

158


Inspiration, Innovation, Evolution

R-410A

DC

DC

INVERTER

GENERAL CHARACTERISTICS

Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •

Indoor unit internal expansion system.

Voltage-free ON/OFF dry contact.

Available pressure up to 200 Pa.

220 V ALARM OUTPUT.

Indoor unit 280 with Inverter fan.

TEMPERATURE ADJUSTMENT / GREATER COMFORT

+

VOLTAGE-FREE CONTACTS

ZEN HIGH CAPACITY COMMERCIAL

+

KCT-02.1 SR (*) RECOMMENDED

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

KI-02.3 S

CENTRALISED

KCT-02.1 SR

KC-01 S

KC-02.1 H

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

K01-KNX

K01-WIFI

KAYNET CONTROL

159


HIGH CAPACITY COMMERCIAL RANGE WATER CONDENSED

LARGE CAPACITY DUCTS WATER CONDENSED TECHNICAL SPECIFICATIONS KPDHF-250W DN3

KPDHF-280W DN3

KPDHF-560W DN3

kW

12.6/25.2/26.6

14.1/28.0/29.6

14.1/56.0/59.2

Kcal/h

10836/21672/22876

12126/24080/25456

12126/48160/50912

W

6310

7610

15600

kW

14.5/27.0/28.2

17.0/31.5/32.9

17.0/63.0/65.8

Kcal/h

12470/23220/24252

14620/27090/28294

14620/54180/56588

W

5960

7340

15060

SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input

KPDHF-250 DN3.0

KPDHF-280 DN3.0

KPDHF-560 DN2.4

3

m /h

4600/4000/3600

4600/4000/3600

10100/8400/7000

Maximum pressure available

Pa

200

200

200

Sound pressure (low speed)

dB (A)

50

50

57

Width/Height/Depth

mm

1443/470/810

1443/470/810

1970/668/903

Net weight

Kg

108

108

235

INDOOR UNIT Air flow

Power wiring

mm

(2+T)x4

(2+T)x4

(2+T)x4

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

2

OUTDOOR UNIT Outdoor modules No Models Compressor type Sound pressure

dB (A)

Refrigerant

K2F-252 DN3W

K2F-280 DN3W

K2F-560 DN3W

1

1

2**

K2F-252 DN3W

K2F-280 DN3W

K2F-280 DN3W K2F-280 DN3W

Scroll Inverter

Scroll Inverter

Scroll Inverter

Scroll Inverter

51

52

52

52

R-410A

R-410A

R-410A

R-410A

gr

2000

2000

2000

2000

Inlet liquid pipe Liquid*

mm (inch")

ø9.52 (3/8")

ø9.52 (3/8")

ø15.9 (5/8")

Inlet liquid pipe Gas*

mm (inch")

ø22.2 (7/8")

ø22.2 (7/8")

ø28.6 (1 1/8")

Max. piping length

m

150

150

150

Pipe height difference

m

50

50

50

Width/Height/Depth

mm

780/1000/550

780/1000/550

780/1000/550

780/1000/550

Net weight

Kg

146

146

146

146

(4+T)x4

(4+T)x6

(4+T)x6

(4+T)x6

3x0.75

3x0.75

3x0.75

3x0.75

380-415/3/50

380-415/3/50

380-415/3/50

380-415/3/50

Refrigerant volume

Power wiring (10 m max.)

mm

2

Shielded communication wires

mm

2

Power supply

V / F / Hz

Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 90 metres, please check diameter with our Technical Department. **KCME branch pipe (200€) is required for joining outdoor modules

160


Inspiration, Innovation, Evolution

R-410A

DC

GENERAL CHARACTERISTICS

Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •

Indoor unit internal expansion system.

220 V ALARM OUTPUT.

Available pressure up to 200 Pa.

Voltage-free ON/OFF dry contact.

Smaller units, 200, 250 and 280 have Inverter indoor unit fan motor.

CONDENSED BY WATER

+ +

ZEN HIGH CAPACITY COMMERCIAL

TEMPERATURE ADJUSTMENT / GREATER COMFORT

VOLTAGE-FREE CONTACTS

KCT-02.1 SR (*) RECOMMENDED

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.

SINGLE

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range INDIVIDUAL

KI-02.3 S

CENTRALISED

KCT-02.1 SR

KC-01 S

KC-02.1 H

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

K01-KNX

K01-WIFI

KAYNET CONTROL

161


HIGH CAPACITY COMMERCIAL RANGE STATIC PRESSURE GRAPHS

HIGH CAPACITY DUCTS

STATIC PRESSURE GRAPHS

KPDHF-200 DN3.0

KPDHF-250 (280) DN3.0

162


Inspiration, Innovation, Evolution

ZEN HIGH CAPACITY COMMERCIAL

KPDHF-400(450) DN 2.4

KPDHF-560 DN 2.4

56KW/h (50Hz)

163


HIGH CAPACITY COMMERCIAL RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

VOLKSWAGEN DEALERSHIP Location: Cabrera de Mar Units installed: High Capacity Zen

THE HIGH-CAPACITY ZEN RANGE FOR COMMERCIAL APPLICATIONS OFFERS MULTIPLE INSTALLATION POSSIBILITIES THAT ARE HIGHLY ENERGY-EFFICIENT AND ENVIRONMENTALLYFRIENDLY. HIGH-CAPACITY EQUIPMENT IS NOTABLE FOR ITS ABILITY TO PROVIDE COMFORT TO PREMISES THAT REQUIRE LARGE AIRFLOWS.

OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN ZEN HOTELS, PUBLIC BUILDINGS HOSPITALS, HEALTH CLINICS AND CENTRES Autism Association of Jeréz (Cádiz), Joan XXIII Hospital (Tarragona), Salamanca Hospital (Salamanca), Sagrado Corazón Health Clinic (Madrid), Museum of Oil (Jaén), Depentya Foundation (Seville), Nuevo Arcangel Football Stadium (Córdoba)

PRIVATE RESIDENCES Residential Complex (Vera), Alpe Property Developments (Tortosa), 134 private residences in East Seville (Seville), Mercainmo Property Developments (Lleida), Residential Complex (Marbella), 503 private residences in Bekinsa Residential Complex (Seville), Las Brisas Hotel (Llanes) BUSINESS CENTRES AND

164

OFFICES Navarrete Offices (La Rioja), Eder Epele offices (Guipúzcoa), Greg Business Centre (Barcelona), Trade Fair (Valladolid), Electric Rooms- Asturiana del Zinz S.A.U. (Asturias), Galvanizados Avilés offices (Avilés), Retevisión Valladolid (Valladolid), Eiffage Energy offices (Ávila), Acofarma offices (Terrassa), Jordi Verna offices (Granollers), Banca March offices (Mal-

lorca), Carrefour offices (Málaga), Barceló Market (Madrid), Day SWRO Desalination offices (Marruecos), Caja Rural Zamora bank offices (Zamora)

RESTAURANTS 100 Montaditos Brewery (Córdoba), Vermut Rofes Restaurants (Reus), La Sureña Brewery (Córdoba), WOK Restaurant (Cáceres)

COMMERCIAL BUILDING Unity Skates shop (Zaragoza), Lecrerc Mall (Málaga), Confecciones Rubio clothes shop (Cádiz, Seville and Córdoba), Aurgi (Madrid), Toyota authorised dealer (Oviedo), Stradivarius (Manresa), Vitaldent dental clinic (different locations), Lacoste (Vilagarcía de Arousa), Lowfit Gym (Seville), Basic Fit Gym (Madrid) , Alimerka Supermarkets (León)


Inspiration, Innovation, Evolution

ENCUENTRO

ZEN HIGH CAPACITY COMMERCIAL

FASHION STORES

Location: Madrid and Seville Units installed: High Capacity Zen Capacity: 100 kW

BASIC FIT GYM

Location: Madrid Units installed: High Capacity Zen Capacity: 140 kW

165


VENTILATION HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY SYSTEMS................................................................168 ERP PRO..........................................................................................170 AZURE..............................................................................................172 STATIC PRESSURE AND EFFICIENCY GRAPHS.............................174


VENTILATION HRV

VENTILATION HEAT RECOVERY SYSTEMS RANGE


HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY

HEAT RECOVERY HEAT RECOVERYSYSTEMS RANGE

Frigicoll’s heat recovery systems range includes the AZURE and ERP PRO models. These models have been designed to meet Ecodesign 2018 EU Commission legislation requirements. ERP PRO units provide users with high airflows while keeping a high energy efficiency. They also include multiple control options that add more efficiency to the equipment.

ERP PRO HEAT RECOVERY UNITS

The AZURE heat recovery units range includes the most efficient units of FRIGICOLL. They can reach an efficiency of up to 93%. Besides, they include a wide range of control options and communication protocols.

NEW

(Page 170)

RATED AIR FLOW (m3/h)

800

1000

1400

ERP PRO ERP PRO 1200

AZURE HEAT RECOVERY UNITS RATED AIR FLOW (m3/h)

(Page 172)

ERP PRO 2200

NEW 500

700

AZURE 500

AZURE 700

AZURE

168

900


Inspiration, Innovation, Evolution

Frigicoll’s heat recovery systems are highly-efficient cross airflow units. This range of products is wide enough to meet the needs of any premises.

1800

2300

2600

3000

4000

ERP PRO 4200

VENTILATION HRV

ERP PRO 3200

All FRIGICOLL’s heat recovery units provide high energy efficiency, low sound levels and high heat exchange. They also include F6 and F7 filters. The installation of higher density filters or a third filter in the air supply duct is optional.

1400

AZURE 1400

1800

2200

AZURE 2200

2600

3200

AZURE 3200

169


HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY

ERP PRO

NEW

TECHNICAL SPECIFICATIONS ERP PRO 1200 Heating efficiency

ERP PRO 2200 ERP PRO 3200 ERP PRO 4200

EN308: 5ºC outdoors / 25ºC indoors

%

73

73

73

73

Winter: -3ºC outdoors / 22ºC indoors

%

80

82

83

83

Summer: 35ºC outdoors / 24ºC indoors

%

73

74

73

73

Number of fans

2

Fan Type Rated air flow (min.-max.) Unit

ERP 2018, EC motor m³/h

820 (200 - 1140)

1400 (200 - 2000)

2325 (750 - 3300)

3000 (800 - 4240)

Pa

695 (825 - 530)

500 (700 - 240)

505 (800 - 60)

520 (750 - 260)

dB (A)

49

49

53

48

W

500x2

480x2

780x2

1500x2

Width/Height/Depth

mm

1220/500/1850

1368/573/2025

1827/668/2500

2000/668/2500

Weight

Kg

98

155

205

260

V/ph/Hz

220-240/1/50

220-240/1/50

220-240/1/50

380/3/50

Rated static pressure (max.-min.) Sound Pressure Level Max. power input

Power Supply Exchanger material

Aluminium

By-pass damper (Free cooling) Sizes of the duct’s flanges

Yes mm

300x300

Supply / exhaust air filter Working Range

450x450 F7/F6

ºC

Notes: EN 308 conditions, +5°C and 70” RH outdoor air, 25°C and 28% RH indoor air. The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.

170

350x350

From -10ºC to 40ºC

500x500


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS •

Compatible with ECODESIGN 2018 EU Commission regulation.

F7 and F6 series filters (optional filters F8 and F9).

Unit’s by-pass control.

Ventilators with EC motor, ERP 2018.

Weekly timer.

Standard by-pass gate for ventilation.

Reports on filters condition.

Up to three air flow speeds adjustable.

Instant information on components malfunctions.

Reports on filters condition.

Optional heat resistors control.

ModBus control available.

+ +

VENTILATION HRV

SENSO CONTROLLER:

F6, F8 AND F9 FILTERS (OPTIONAL)

CO2 (OPTIONAL)

Efficiency and air flow graphics on page 174. Senso controller

ACCESSORIES. PREH 1200 ERP

F6 filter 1200 ERP

F8 filter 1200 ERP

F9 filter 1200 ERP

PREH 2200 ERP

F6 filter 2200 ERP

F8 filter E2200 ERP

F9 filter 2200 ERP

PREH 3200 ERP

F6 filter 3200 ERP

F8 filter 3200 ERP

F9 filter 3200 ERP

PREH 4200 ERP

F6 filter 4200 ERP

F8 filter 4200 ERP

F9 filter 4200 ERP

VOD KitAZ (CO2 sensor)

171


HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY

AZURE

NEW

TECHNICAL SPECIFICATIONS AZURE 500 Heating efficiency

AZURE 700 AZURE 1400 AZURE 2200 AZURE 3200

EN308: 5ºC outdoors / 25ºC indoors

%

82

83

82

81

81

Winter: -3ºC outdoors / 22ºC indoors

%

83

84

89

89

89

Summer: 35ºC outdoors / 24ºC indoors

%

78

78

77

79

79

Number of fans

2

Fan Type Rated air flow (min.-max.) Unit

Rated static pressure (max.-min.) Sound Pressure Level Max. power input Width/Height/Depth

Weight Power Supply By-pass damper (Free cooling) Sizes of the duct’s flanges

ERP 2015, EC motor m³/h

500 (200-725)

700 (200-850)

Pa

290 (740-100)

180 (640-50)

350 (690-180)

450 (820-220)

420 (1010-200)

dB (A)

42

47

54

52

54

W

338

340

1000

1000

2000

mm

880/360/1300

1055/360/1500

1355/400/1550

1675/485/1850

1950/567/2125

Kg

80

125

150

185

225

V/ph/Hz

230/1/50

230/1/50

230/1/50

230/1/50

230/1/50

500x300

700x400

AZURE 2200 R

AZURE 3200 R

Yes mm

300x150

400x200

Supply / exhaust air filter Working Range

1400 (500-1700) 2200 (450-2600) 3200 (840-3600)

500x250 F7/F6

ºC

From -20ºC to 40ºC

Notes: EN 308 conditions, +5°C and 70” RH outdoor air, 25°C and 28% RH indoor air. The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.

AZURE 500 R Heating efficiency

AZURE 700 R

EN308: 5ºC outdoors / 25ºC indoors

%

82

83

82

81

81

Winter: -3ºC outdoors / 22ºC indoors

%

83

84

89

89

89

Summer: 35ºC outdoors / 24ºC indoors

%

78

78

77

79

79

Number of fans

2

Fan Type Rated air flow (min.-max.) Unit

Rated static pressure (max.-min.) Sound Pressure Level

ERP 2015, EC motor m³/h

500 (200-725)

700 (200-850)

Pa

290 (740-100)

180 (640-50)

350 (690-180)

450 (820-220)

420 (1010-200)

42

47

54

52

54

W

338

340

1000

1000

2000

Width/Height/Depth

mm

880/360/1300

1055/360/1500

1355/400/1550

1675/485/1850

1950/567/2125

Weight Electrical heater power

Kg

80

125

150

185

225

kW

1.35

1.9

3.8

6

8.8

V/ph/Hz

230/1/50

380/3/50

380/3/50

380/3/50

380/3/50

ºC

8.1

8.1

8.1

8.1

8.2

V/ph/Hz

230/1/50

230/1/50

230/1/50

230/1/50

230/1/50

mm

300x150

400x200

500x250

500x300

700x400

Power Supply Temperature increase

Unit’s power supply By-pass dumper (Free cooling) Sizes of the duct’s flanges

Yes

Supply / exhaust air filter Working Range

F7/F6 ºC

Notes: EN 308 conditions, +5°C and 70” RH outdoor air, 25°C and 28% RH indoor air. The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.

172

1400 (500-1700) 2200 (450-2600) 3200 (840-3600)

dB (A)

Max. power input

Electrical heater

AZURE 1400 R

From -20ºC to 40ºC


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS • Compatible with ECODESIGN 2018 EU Commission regulation.

SENSO PLUS CONTROLLER:

• F7 and F6 series filters (optional filters F8 and F9).

• Weekly timer.

• Low sound levels.

• Unit’s by-pass control. • Reports on filters condition.

• Cross airflow heat exchangers.

• Instant information on components malfunctions.

• High energy efficiency.

• ModBus, EXOline, BACnet and LonWorks control available.

• Ventilators with EC motor, ERP 2015.

• Optional heat resistors control.

+ +

VENTILATION HRV

• Up to three air flow speeds adjustable.

F6, F8 AND F9 FILTERS (OPTIONAL)

CO2 (OPTIONAL)

Senso Plus Controller Efficiency and air flow graphics on page 175.

ACCESSORIES.

ACCESSORIES

ACCESSORIES

F6 filter 500 Azure

F8 filter 500 Azure

F9 filter 500 Azure

F6 filter 700 Azure

F8 filter 700 Azure

F9 filter 700 Azure

F6 filter 1400 Azure

F8 filter 1400 Azure

F9 filter 1400 Azure

F6 filter 2200 Azure

F8 filter 2200 Azure

F9 filter 2200 Azure

F6 filter 3200 Azure

F8 filter 3200 Azure

F9 filter 3200 Azure

VOD KitAZ (CO2 sensor)

173


HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY

ERP PRO STATIC PRESSURE AND EFFICIENCY GRAPHS ERP PRO 1200 UNIT

ERP PRO 2200 UNIT

ERP PRO 3200 UNIT

ERP PRO 4200 UNIT

NOTE: The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.

174


Inspiration, Innovation, Evolution

AZURE STATIC PRESSURE AND EFFICIENCY GRAPHS AZURE 500

AZURE 700

VENTILATION HRV

AZURE 1400

AZURE 2200

AZURE 3200

NOTE: The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.

175


AMAZON INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE.........................................................178 INDOOR UNITS......................................................................................184 HIGH WALL.......................................... ...........KAYF.......................188 DOUBLE FLOW CONSOLE...............................KSDF........................190 FLOOR STANDING EXPOSED/CONCEALED.......KS(E)F.......................192 CEILING/FLOOR................................... ............KPCF........................ 194 ONE WAY CASSETTE.......................... ............KCOF.........................196 ART FLUX 360ยบ (600x600) CASSETTE..........KCIF.......................... 198 ART FLUX 360ยบ CASSETTE................. ............KCIBF...................... 200 DUCTS.................................................. ............KPDF........................ 202 STATIC PRESSURE GRAPHS........ ............................................ 204 HIGH PRESSURE DUCTS.................... ............KPDHF.................... 208 STATIC PRESSURE GRAPHS........ ............................................ 210 KAHU.................................................... ............KAHU...................... 214 HOT WATER INDOOR UNIT................. ............KWF......................... 216 OUTDOOR UNITS....................................................................................218 2 PIPES ...................................................................................................222 MINI AMAZON II SINGLE-PHASE.............................. ............KMF DVN2.............. 224 THREE-PHASE.......................................... KMF DTN2.............. 226 AMAZON UNITARIO SIDE DISCHARGE..........KMF........................ 228 AMAZON UNITARIO TOP DISCHARGE DN3...K2UF DN3............... 230 AMAZON UNITARIO TOP DISCHARGE DN4 S...K2UF DN4S............ 232 AMAZON IV PRO................................. ............K2F DN4S............... 236 AMAZON III W..................................... ............K2F DN3W.............. 238 3 PIPES ...................................................................................................240 AMAZON III PRO.................................. ............K3F DN3S............... 242 CHANGEOVER BOXES................... ............KVB......................... 244 DIMENSIONING ................................................................................... 246 DISTANCES AND HEIGHT DIFFERENCES .......................................... 256 KEY INSTALLATIONS .......................................................................... 262


AMAZON INDUSTRIAL VRF

AMAZON INDUSTRIAL VRF RANGE


INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

AMAZON

INDUSTRIAL VRF RANGE

Within the world of air-conditioning, the variable refrigerant flow systems (VRF) are the most versatile in terms of installation possibilities and technological innovation. Thanks to the DC Inverter technology, which varies the frequency of the compressor motor and fan motor of the outdoor unit depending on the total required load, and thanks to electronic expansion valves (both in the outdoor and the indoor units), which regulate the flow of refrigerant depending on the load required for each area, higher levels of efficiency and superior energy savings are achieved. The installation distances available are among the longest in the market, reaching up to 200 meters of equivalent length between the outdoor unit and the farthest indoor unit. The possibilities of the indoor units are endless, not only for the different models available, but also for their power range, which is so wide that it covers from 1.5 kW to 56 kW and allows

“THE BROADEST PRODUCT RANGE ON THE MARKET” for installing up to 64 indoor units in the same cooling circuit. The independent control of indoor units allows each user to choose its own comfort level without interfering with the rest of users. Our wide range of controllers provides end-user with many options to define its level of comfort. They allow installing from a simple individual control (wireless or wired), a centralised control, a computer control and even the possibility of managing the installation from a comprehensive building management system BMS (LONWORKS, MODBUS, BACNET and KNX).

AMAZON UNITARIO TOP DISCHARGE DN4S (2 PIPES) • • • • •

NEW

From 28 to 90 kW Up to 53 indoor units Up to 150% simultaneity Autoaddresing XYE port to connect a centralised control for indoor units DC

INVERTER

OUTDOOR

• Inverter fan motors

+

EFFICIENCY

• Full DC Inverter Compressors

1000 m FOR PIPELINES

• Plate exchanger: In Cooling mode, it improves refrigerant subcooling; in Heating mode, it improves units’ performance by steam injection.

178


Inspiration, Innovation, Evolution

INDOOR UNITS WITH DC INVERTER FAN Most KAYSUN AMAZON indoor units include a DC Inverter motor fan. This development provides units with a much more accurate control, and greater output and energy savings, and it reduces sound (low) pressure. Our units are better suited to the installation requirements of the areas in need of air conditioning, thereby making users' comfort, well-being and energy savings a top priority.

DUCTS

BUILT-IN EXV VALVE

STATIC PRESSURE ADJUSTMENT WITH ROTARY SWITCH (OPTIONAL)

INTERACTIVE DISPLAY

REAR/LOWER OUTLET PANEL

LOW SOUND LEVELS

FRAMES INCLUDE FOR AIR SUPPLY DUCT AND AIR RETURN DUCT

CASSETTE ART FLUX 360º (600x600)

HIGH PRESSURE DUCTS

360° AIRFLOW

HIGH AIRFLOW

FRESH AIR SUPPLY

WIDE POWER RANGE

AMAZON INDUSTRIAL VRF

WALL-MOUNTED

DRAIN PUMP AS STANDARD

CASSETTE ART FLUX 360º

CEILING/FLOOR

360° AIRFLOW

AIR FLOW DISTRIBUTION UP TO 8 METERS

FRESH AIR SUPPLY

DOUBLE INSTALLATION

DRAIN PUMP AS STANDARD

179


INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

HIGH INVERTER TECHNOLOGY The design of the Scroll DC Inverter compressor is based on the highest technology available. With a more compact structure, this compressor provides maximum outputs, increases efficiency and reduces power consumption when the system is working at partial loads. The compressor, which has been optimized for using R410A ecological refrigerant, has received the highest energy classification for both cooling and heating operation - EER and COP. Speed in direct current can be adjusted and results in energy savings of up to 25%, more than any other conventional equipment on the market.

new structure and high energy efficiency at partial load. new serrated design for R410A 50% lighter, thanks to its new design the elaborated design of the compressor allows a more centralised magnetic flow it uses a DC motor inverter

COMPENSATION TECHNOLOGY FOR OIL DISTRIBUTION

Outdoor units ensure individualised control and homogeneous distribution of oil between modules so that the compressor is able to provide a smooth and reliable performance. The oil balance and outlet pipes send the compressor's remaining oil to a system that will distribute it uniformly to the other compressors.

The oil centrifuge separator, is capable to work with an efficiency over 99%, by sending oil to the compressors on time and effectively in order to ensure that they have the correct amount of oil. This system is designed to extend the working life of KAYSUN units' compressors as much as possible.

HIGH-PRESSURE GAS

pipe to condenser

TUBERÍA DE ENTRADA

High-performance 99% oil separator oil balance port between modules DISCHARGE PIPE

TUBERÍA DE DESCARGA

CARTER DE ACEITE

OIL CLEARING PIPE II OIL BALANCE PIPE BETWEEN MODULES III

TUBERÍA DE COMPENSACIÓN DE ACEITE

OIL BALANCE PIPE I

pipe from indoor units

compressor

SUCTION PIPE

CENTRALISED WINDING

The DC Inverter compressor's technology used in KAYSUN's AMAZON units, are fitted with centralised winding instead of distributing winding. This type of winding consists of very powerful magnets that allow for increasing the force of rotation and therefore, the compressor's effectiveness. EFFECTIVENESS OF THE COMPRESSOR

70% reduction New DC motor Common DC motor

20

180

40

60

80

100

ROTOR SPEED (S-1)

Dispensing coil

Central coil


Inspiration, Innovation, Evolution

SMART SOFT-STARTER TECHNOLOGY

DC INVERTER compressors characterise by a soft, low frequency and low power consumption starter. This reduces the risk of overloading the power grid and prevents excessive consumption peaks during outdoor unit starting.

STARTING FREQUENCY (%)

600

(*) Comparison between starting with an inverter starter and with a conventional starter. 500

400

FLUCTUATION TEMPERATURE (ºC)

300

200 Inverter

1

2 Starting of INVERTER Starting of

100

ON/OFF

On/off switch TIME (H) EFFECTIVENESS OF THE COMPRESSOR

1

2

3

4

5

TIME (SEC)

6

FAN Our units are extremely quiet and efficient thanks to their DC Inverter fan, which allows for reducing noise level from 2-5 dB (A) and increases the airflow from 1000 to 4000m3/h.

PROPELLER FAN

The new helical shape of the fun's blades supplies a large volume of air whilst reducing vibrations and resistance to a minimum.

60 Pa

OPTIMISED AIRFLOW OUTLET

AMAZON INDUSTRIAL VRF

The efficiency of the fan’s airflow has been improved thanks to the fan’s new design. This, in combination with the DC Inverter motor, allows for a static pressure increase of up to 60 Pa, a pressure loss decrease and a 10% optimization of the airflow. DC INVERTER MOTOR

The fan’s DC Inverter motor consumes minimal energy since the fan speed can be regulated depending on the power demand and the operating pressure of the cooling circuit. EFFECTIVENESS(%)

100

80

ROTOR SPEED (PPM)

60

1000

45% increase

40 18 LEVELS of speed adjustment

20 200 200

1000

MOTOR SPEED (RPM)

SYSTEM PRESSURE (Pa)

181


INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

EASY INSTALLATION AND MAINTENANCE The outdoor units' design allows for an easy installation and maintenance. The new electrical box includes an inspection window in the main electronic board that allows for a straightforward access from outside the equipment. The compressor is located just opposite the electric box to make access easier when its replacement is required. WORKING RANGE

EXCHANGER OPTIMIZATION

Thanks to the new DC Inverter technology, the AMAZON range offers increased operability for cooling and heating modes within a much larger working range, thereby ensuring a perfect airconditioning control during all seasons of the year.

The battery of the 12, 20 and 22 HP models of AMAZON IV has been optimised to reduce their volume by adding an extra row to its large surface. Besides, the delta-shaped heat exchanger helps to improve subcooling.

48 ยบC

21 ยบC

OPERATING MODE LOCKING FUNCTION (2 PIPES) Outdoor temperature

-5 ยบC

From a switch located at the outdoor unit's electronic board, user may select 6 different operating modes for the cooling system:

Outdoor temperature

-20 ยบC

* For further information on AMAZON IV for other ranges, please check temperature tables.

AUTO-ADDRESS OF THE INDOOR UNITS

There are two address setting options for indoor units:

1. Heating mode priority (default). 2. Cooling mode priority. 3. Cooling mode only. 4. Heating mode only. 5.- Unit addressed as no. 63 determines the operating mode. 6. Those units with the same operating mode forming a majority shall determine the operation mode of the whole system.

Automatic: Using the SW6 switch of the outdoor unit (deactivated by default), the outdoor unit automatically distributes the address to the indoor units with no manual adjustment. ROTARY AND CONSTANTLY VENTILATED ELECTRICAL BOX

Manual: The address of all indoor units can be consulted and modifier using the KI-02.3 S wireless controller or the KCT-02.1 SR wired controller.

SW6

The electrical box of the AMAZON IV units, apart from providing boards' electronic parts with constant ventilation by means of a heat dissipation system, is completely rotary in order to facilitate the access inside the unit.

KI-02.3 S controller Wall-mounted No 1

Wall-mounted No 2

OUTDOOR UNIT

CENTRALISED CONTROLLER WIRING INDOOR UNITS

Wall-mounted No 3

All AMAZON systems have an XYE port in the outdoor unit, allowing the three wires of the centralised control cable between the indoor units to be dispensed with.This means that it is possible to connect directly to the XYE port. Wall-mounted No 4

XYE

MODULES AUTOMATIC REDUNDANCY

AMAZON's intelligent control system, defines the boot priority of the module according to the system load, and balances its operating time to optimise reliability and working life of the unit.

182

PORT DE CONNEXION


Inspiration, Innovation, Evolution

A NOD TO ENVIRONMENT WORKING RANGE

The AMAZON units have one of the highest energy efficiency ratings in the market, with very high EER and COP scores. Furthermore, since outdoor units are modular, units with the best EER/COP scores can be combined to provide higher energy efficiency in facilities that require large cooling capacity.

8 / 10 / 12

ECOLOGICAL DESIGN

AMAZON INDUSTRIAL VRF

Kaysun not only offers the most technologically advanced products of the market, but also makes every single effort to produce them under the strictest ecological standards in order to ensure a minimal negative impact on the environment.

14 / 16 / 18 / 20 / 22

R-410A REFRIGERANT

The Amazon system uses the environmentallyfriendly refrigerant R410A, which, in addition to having high efficiency and energy savings it is characterised for being respectful of the ozone layer and helps us to reduce the impact on the environment.

ECOLOGICAL DESIGN

92% recyclable

Energy saving

183


INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

184


Inspiration, Innovation, Evolution

INDOOR UNITS

AMAZON INDUSTRIAL VRF

TECHNICAL SPECIFICATIONS

185


INDUSTRIAL VRF RANGE INDOOR UNITS

INDOOR UNITS RANGE POWER kW

1.5

2.2

WALL-MOUNTED

2.8

3.6

4.5

5.6

KAYF-28 DN3.0

KAYF-36 DN3.0

KAYF-45 DN3.0

KAYF-56 DN3.0

KSDF-36 DN2.3

KSDF-45 DN2.3

(Page 188)

KAYF-22 DN3.0

DOUBLE FLOW CONSOLE

(Page 190) KSDF-28 DN2.3

FLOOR STANDING EXPOSED/CONCEALED

(Page 192) KS(E)F-56 DN2.3 KSEF-56 DN2.3

CEILING / FLOOR

(Page 194) KPCF-56 DN3.0

ONE WAY CASSETTE

(Page 196)

KCOF-22 DN2.4

KCOF-36 DN2.4

CASSETTE ART FLUX 360ยบ (600x600) KCIF-15 DN3.0

KCIF-28(22) DN3.0

(Page 198) KCIF-36 DN3.0

KCIF-45 DN3.0

CASSETTE ART FLUX 360ยบ (Page 200) KCIFB-56 DN3.0

DUCTS

(Page 202)

KPDF-15 DN3.0

KPDF-22 DN3.0

KPDF-28 DN3.0

HOT WATER INDOOR UNIT

POWER kW

7.1

HIGH PRESSURE DUCTS

KAHU

KPDF-45 DN3.0

KPDF-56 DN3.0

11.2

14.0

16.0

KPDHF-140 DN3.0

KPDHF-160 DN3.0

(Page 216)

9.0

KPDHF-71 DN3.0

KPDF-36 DN3.0

KPDHF-90 DN3.0

(Page 208) KPDHF-112 DN3.0

(Page 214) KAHU-200.2

186


Inspiration, Innovation, Evolution

7.1

8.0

9.0

10.0

11.2

12.5

14.0

16.0

18.0

56.0

60.0

KAYF-80 DN3.0

KS(E)F-80 DN2.3

KPCF-90 DN3.0

KPCF-140 DN3.0

KCIFB-71 DN3.0

KCIFB-80 DN3.0

KPDF-71 DN3.0

KPDF-80 DN3.0

KCIFB-100 DN3.0

KPDF-90 DN3.0

KCIB-112 DN3.0

KCIF-140 DN3.0

KPDF-112 DN3.0

KPDF-140 DN3.0

AMAZON INDUSTRIAL VRF

KCOF-71 DN2.4

KWF-140

DOMESTIC HOT WATER

20.0

KPDHF-200 DN3.0

25.0

KPDHF-250 DN3.0

28.0

KPDHF-280 DN3.0

KAHU-360.2

36.0

40.0

KPDHF-400 DN2.4

45.0

KPDHF-450 DN2.4

50.0

KPDHF-560 DN2.4

KAHU-560.2

187


INDUSTRIAL VRF RANGE INDOOR UNITS

WALL-MOUNTED GENERAL CHARACTERISTICS The main features of our wall-mounted units are a DC INVERTER fan and the smart design of their panel. They include a LED display located at the centre of the unit that provides it with a modern design by using the most advanced technology in the market. •

Low noise level, creating a peaceful and comfortable atmosphere.

The swing angle of the louvers may reach up to 90º.

Built-in expansion valve.

ON/OFF dry contact and 220V alarm signal output.

DC INVERTER fan included

Left inlet for installation pipes (front view)

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS MODEL

KAYF-22 DN3.0

KAYF-28 DN3.0

KAYF-36 DN3.0

KAYF-45 DN3.0

KAYF-56 DN3.0

KAYF-80 DN3.0

Cooling capacity

kW

2.2

2.8

3.6

4.5

5.6

8

Cooling capacity

Kcal/h

1892

2408

3096

3870

4816

6880

Heating Capacity

kW

2.4

3.2

4

5

6.3

9

Heating Capacity

Kcal/h

2064

2752

3440

4300

5418

Power input

7740

33 53

W

8

9

19

19

27

Indoor airflow

m3/h

422/393/356

417/370/316

656/573/488

594/507/424

747/648/547

1195/1005/809

Sound pressure

dB (A)

29

29

30

31

34

36

Width/Height/Depth

mm

835/280/203

835/280/203

990/315/223

990/315/223

990/315/223

1194/343/262

Net weight

Kg

8.4

9.5

11.4

12.8

12.8

17

Liquid pipe diameter

mm (inch")

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø6.35 (1/4")

ø9.52 (3/8")

ø9.52 (3/8")

Gas pipe diameter

mm (inch")

ø12.7 (1/2")

ø12.7 (1/2")

ø12.7 (1/2")

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

Drain tube diameter

mm

Ø16

Ø16

Ø16

Ø16

Ø16

Ø16

Power wiring (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power cord

All AMAZON indoor units accept R-410A refrigerant.

188


Inspiration, Innovation, Evolution

DC

INVERTER

R-410A

+ +

INDOOR

DC INVERTER FAN

LOW SOUND LEVEL

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

189

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED


INDUSTRIAL VRF RANGE INDOOR UNITS

DOUBLE FLOW CONSOLE GENERAL CHARACTERISTICS With a modern and cutting-edge design, the consoles can be gracefully incorporated into any space. Their reduced depth, provides the unit with an external flexible design that adapts to every installation, from floor standing installations to low wallmounted installations, without affecting their capacity. •

Thanks to their four return air inlets and two outlets, the unit reach the selected temperature much faster.

DC Inverter fan motor.

Low starting power and precise room temperature adjustment.

The electronic expansion valve is integrated inside the indoor unit.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KSDF-28 DN2.3

MODEL

KSDF-36 DN2.3

KSDF-45 DN2.3

Cooling capacity

kW

2.8

3.6

4.5

Cooling capacity

Kcal/h

2408

3096

3870

Heating Capacity

kW

3.2

4

5

Heating Capacity

Kcal/h

2752

3440

W

25

25

45

Indoor airflow

m3/h

510/430/229

510/430/229

660/512/400

Sound pressure

dB (A)

27

27

36

Width/Height/Depth

mm

700/600/210

700/600/210

700/600/210

Net weight

Kg

15

15

15

Liquid pipe diameter

mm (inch")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Gas pipe diameter

mm (inch")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Drain tube diameter

mm

Ø16

Ø16

Ø16

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Power input

Power supply

All AMAZON indoor units accept R-410A refrigerant.

190

4300 33


Inspiration, Innovation, Evolution

DC

INVERTER

R-410A

+ +

INDOOR

ACCURATE ROOM TEMP. ADJUSTMENT

DC INVERTER FAN

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

191


INDUSTRIAL VRF RANGE INDOOR UNITS

FLOOR STANDING EXPOSED/CONCEALED GENERAL CHARACTERISTICS The streamlined design of this unit, due mainly to its reduced depth, is the perfect solution for saving space and adapting to every installation, from wall-mounted to floor standing, whether totally or partially recessed, thereby gracefully harmonising with the interior design of the room.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO

Built-in expansion valve.

ON/OFF dry contact and 220V V alarm signal output.

Its 12Pa static pressure helps move air supply.

2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KSEF-56 DN2.3

MODEL

KS(E)F-56 DN2.3

KS(E)F-80 DN2.3

Cooling capacity

kW

5.6

5.6

8

Cooling capacity

Kcal/h

4816

4816

6880

Heating Capacity

kW

6.3

6.3

9

Heating Capacity

Kcal/h

5418

5418

7740

W

88

88

130

Indoor airflow

m3/h

1150/970/830

1150/970/830

1380/1100/870

Sound pressure

dB (A)

31

31

33

Width/Height/Depth CONCEALED

mm

-

1500/596/225

1500/596/225

Width/Height/Depth EXPOSED

mm

1345/544/212

1345/544/212

1380/1100/870

Net weight CONCEALED

Kg

-

42

44

Net weight EXPOSED

Kg

41

41

42.5

Liquid pipe diameter

mm (inch")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Gas pipe diameter

mm (inch")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Drain tube diameter

mm

Ø25

Ø25

Ø25

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Power input

Power supply

All AMAZON indoor units accept R-410A refrigerant.

192


Inspiration, Innovation, Evolution

R-410A

CONCEA

LED

EXPOS

ED

+

12 PA STATIC PRESSURE

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

193

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED


INDUSTRIAL VRF RANGE INDOOR UNITS

CEILING / FLOOR GENERAL CHARACTERISTICS Ceilling/Floor VRF indoor unit with DC INVERTER motors. Its compact design helps integrating the unit into every environment. As its name suggests, these units can be installed on the ceiling in horizontal position and on the floor in vertical position. The design of their condensation water tray so permits.

MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO

Built-in expansion valve.

ON/OFF dry contact and 220V V alarm signal output.

Smoother air flow with less turbulences. Thanks to the multi blades fan and the design of its louvers, the airflow is softer and more comfortable.

COMPATIBLE WITH

2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

Indoor units with DC INVERTER fan.

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KPCF-56 DN3.0

MODEL

KPCF-90 DN3.0

KPCF-140 DN3.0

Cooling capacity

kW

5.6

9

14

Cooling capacity

Kcal/h

4816

7740

12040

Heating Capacity

kW

6.3

10

15.5

Heating Capacity

Kcal/h

5418

8600

13330

W

94

126

130

Indoor airflow

m3/h

930/830/720

1280/1170/1050

1890/1700/1580

Sound pressure

dB (A)

36

40

42

Width/height/depth (floor installation)

mm

990/660/203

1280/660/203

1670/680/244

Net weight

Kg

27

33.5

49

Liquid pipe diameter

mm (inch")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Gas pipe diameter

mm (inch")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Drain tube diameter

mm

Ø25

Ø25

Ø25

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Power input

Power supply All AMAZON indoor units accept R-410A refrigerant.

194


Inspiration, Innovation, Evolution

DC

INVERTER

R-410A

+

INDOOR

DC INVERTER FAN

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

195

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED


INDUSTRIAL VRF RANGE INDOOR UNITS

ONE WAY CASSETTE GENERAL CHARACTERISTICS ONE WAY CASSETTE. Stands at just 153mm in height, depending on the capacity of the unit. It has a compact and light design, making it very easy to install and maintain in any space. These units are perfectly merged with the ceiling, creating a clean and subtile aesthetic. •

The control box is built into the body of the unit. This saves space and allows facilitates maintenance.

Standard condensation pump.

It has a very reduced height, making it ideal for very low suspended ceilings.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KCOF-22 DN2.4

MODEL

KCOF-36 DN2.4

KCOF-71 DN2.4

Cooling capacity

kW

2.2

3.6

7.1

Cooling capacity

Kcal/h

1892

3096

6106

Heating Capacity

kW

2.6

4

8

Heating Capacity

Kcal/h

2236

3440

6880

W

41

41

55

Indoor airflow

m3/h

523/404/275

573/456/315

933/749/592

Sound pressure

dB (A)

30

34

37

Width/Height/Depth

mm

1054/153/425

1054/153/425

1275/189/450

Net weight

Kg

12.5

13

19.5

Width/Height/Depth (panel)

mm

1180/25/465

1180/25/465

1350/25/505

Net weight (panel)

Kg

3.5

3.5

4

Liquid pipe diameter

mm (inch")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø9.53 (3/8")

Gas pipe diameter

mm (inch")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø15.9 (5/8")

Drain tube diameter

mm

Ø25

Ø25

Ø25

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Power input

Power supply

2

All AMAZON indoor units accept R-410A refrigerant.

196


Inspiration, Innovation, Evolution

R-410A

+

STANDARD CONDENSATION PUMP

+

UP TO 153 MM IN HEIGHT

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

197

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED


INDUSTRIAL VRF RANGE INDOOR UNITS

ART FLUX 360º (600x600) CASSETTE GENERAL CHARACTERISTICS With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact and lighter, less space and equipment are needed to install it. They can be completely integrated into any space, including shallow ceilings, without sticking out. •

On/Off dry contact and 220 V alarm output.

Integrated control box inside the unit's body; it saves space and allows for ceiling installation.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

Ducts pre-installation holes, to supply air to adjoining rooms.

Electronic expansion valve kit on one side of the unit.

Indoor units with DC INVERTER FAN.

Fresh air possibility to enter directly into the room through a preinstallation hole located at the unit’s body.

Standard condensation pump.

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KCIF-15 DN3.0

MODEL

KCIF-28(22) DN3.0 ** KCIF-36 DN3.0

KCIF-45 DN3.0

Cooling capacity

kW

1.5

2.8(×2.2)

3.6

4.5

Cooling capacity

Kcal/h

1290

2408(×1892)

3096

3870

Heating Capacity

kW

1.7

3.2(×2.6)

4

5

Heating Capacity

Kcal/h

1462

2742(×2236)

3440

4300

W

14

15

21

21

Indoor airflow

m3/h

526/449/364

576/503/405

604/516/400

604/516/400

Sound pressure

dB (A)

21

22

27

27

Width/Height/Depth

mm

570/260/570

570/260/570

570/260/570

570/260/570

Net weight

Kg

16

16

17.5

17.5

Width/Height/Depth (panel)

mm

648/50/648

648/50/648

648/50/648

648/50/648

Panel net weight

Kg

2.5

2.5

2.5

2.5

Liquid pipe diameter

mm (inch")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Gas pipe diameter

mm (inch")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Drain tube diameter

mm

Ø25

Ø25

Ø25

Ø25

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power input

Power supply

All AMAZON indoor units accept R-410A refrigerant. **KCIF-28 DN3.0 model is compatible with KCIF-22 DN3.0 model.

198


Inspiration, Innovation, Evolution

DC

INVERTER

R-410A

+ +

INDOOR

DC INVERTER FAN

360º AIR DIFFUSION

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

199


INDUSTRIAL VRF RANGE INDOOR UNITS

CASSETTE ART FLUX 360º GENERAL CHARACTERISTICS With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out. •

Electronic expansion valve kit on one side of the unit.

On/Off dry contact and 220 v Alarm output.

Integrated control box inside the unit's body; it saves space and allows for ceiling installation.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

Ducts pre-installation holes, to supply air to adjoining rooms.

Fresh air possibility to enter directly into the room through a preinstallation hole located at the unit’s body.

Indoor units with DC INVERTER FAN.

Standard condensation pump.

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KCIBF-56 DN3.0

MODEL

KCIBF-71 DN3.0

KCIBF-80 DN2.3

KCIBF-100 DN3.0

KCIBF-112 DN3.0

KCIBF-140 DN3.0

Cooling capacity

kW

5.6

7.1

8

10

11.2

14

Cooling capacity

Kcal/h

4816

6106

6880

8600

9632

12040

Heating Capacity

kW

6.3

8

9

11

12.5

15

Heating Capacity

Kcal/h

5418

6880

7740

9460

10750

12900

W

31

46

48

110

110

120

33 1727/1426/1220

Power input Indoor airflow

m3/h

1029/857/704

1200/996/748

1264/1055/811

1596/1239/1030

1596/1239/1030

Sound pressure

dB (A)

34

34

35

36

36

Width/Height/Depth

mm

904/230/840

904/230/840

904/230/840

904/300/840

904/300/840

904/300/840

Net weight Width/Height/Depth (panel) Panel net weight

Kg

24

24

24

27.4

27.4

30

mm

950/55/950

950/55/950

950/55/950

950/46/950

950/46/950

950/46/950

Kg

5

5

5

5

5

5

Liquid pipe diameter

mm (inch")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Gas pipe diameter

mm (inch")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Drain tube diameter

mm

Ø32

Ø32

Ø32

Ø32

Ø32

Ø32

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

All AMAZON indoor units accept R-410A refrigerant.

200

33

35


Inspiration, Innovation, Evolution

DC

INVERTER

R-410A

+ +

INDOOR

DC INVERTER FAN

360º AIR DIFFUSION

KI-02.3 S

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

CHOOSE YOUR

CONTROLLER

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

AMAZON INDUSTRIAL VRF

(*) RECOMMENDED

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

BMS AND SOFTWARE

K01-LON

K02-MODBUS

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

K01-KNX

K01-WIFI

201


INDUSTRIAL VRF RANGE INDOOR UNITS

Ducts GENERAL CHARACTERISTICS The VRF AMAZON Duct units with DC INVERTER fan motors have a compact and versatile design that allows for adapting to every false ceiling installation. We truly believe this is a thorough product.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

• Units with DC Inverter fan motor.

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

• Broad range of capacities: from 1.5 kW to 14 kW, eleven models in total. • Double return system possibility (rear inlet or lower inlet).

AMAZON IV PRO 2 PIPES see pag. 236

• Pre-installed entry in the unit’s body for fresh air. • Flanges for fitting outlet and return ducts.

AMAZON III W

• Compatible with AIRZONE air-conditioning zoning systems.

2 PIPES see pag. 238

• It contains a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms with a limited false ceiling.

AMAZON III PRO 3 PIPES see pag. 242

• On/Off dry contact and Alarm 220 V output. • Receiver detaches up to 10 meters (optional cable). • Possibility to change available static pressure by means of a dipswitch. • Standard condensation pump.

33

TECHNICAL SPECIFICATIONS KPDF-15 DN3.0

MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply

kW Kcal/h kW Kcal/h W m3/h Pa dB (A) mm Kg mm (inch") mm (inch") mm mm2 mm2 V / F / Hz

All AMAZON indoor units accept R-410A refrigerant.

202

KPDF-22 DN3.0

KPDF-28 DN3.0

KPDF-36 DN3.0

33

KPDF-45 DN3.0

1.5

2.2

2.8

3.6

4.5

1290

1892

2408

3096

3870

1.7

2.6

3.2

4

5

1462

2236

2752

3440

4300

39

39

39

45

58

600/550/460

600/550/460

600/550/460

660/460/400

850/800/650

40

60

60

60

60

31

31

31

33

33

740/210/500

740/210/500

740/210/500

740/210/500

960/210/500

17.5

17.5

17.5

17.5

22.5

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø6.35 (1/4")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø25

Ø25

Ø25

Ø25

Ø25

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50


Inspiration, Innovation, Evolution

A

DC

INVERTER

R-410A

+

INDOOR

B

DC INVERTER FAN

+

MANUAL PRESSURE ADJUSTMENT AVAILABLE

Compatible with

KCT-02.1 SR (*) RECOMMENDED

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

For further information, please see our Controllers Range

INDIVIDUAL

KI-02.3 S

CHOOSE YOUR

CONTROLLER

CENTRALISED

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

K01-KNX

K01-WIFI

K01-LON

K02-MODBUS

MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply

K01 MODBUS 1/4/8/32

KPDF-56 DN3.0

K01-BACNET

KPDF-71 DN3.0

KAYNET CONTROL

KPDF-80 DN3.0

KPDF-90 DN3.0

KPDF-112 DN3. 0

KPDF-140 DN3.0

5.6 7.1 8 9 11.2 14 kW 4816 6106 6880 7740 9632 12040 Kcal/h 6.3 8 9 10 12.5 15.5 kW 5418 6880 7740 8600 10750 13330 Kcal/h 89 89 98 108 178 204 W 3 980/920/740 1350/1250/1050 1700/1400/1100 1800/1400/1150 2200/1900/1600 2800/2300/1900 m /h 60 60 110 110 120 170 Pa 33 34 37 37 37 38 dB (A) 960/210/500 1180/210/500 1180/270/775 1180/270/775 1180/270/775 1240/300/865 mm 22.5 28 38 40 40 49 Kg ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") mm (inch") ø9.52 (3/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") mm (inch") Ø15.9 (5/8") Ø25 Ø25 Ø25 Ø25 Ø25 Ø25 mm (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 mm2 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 mm2 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

203

AMAZON INDUSTRIAL VRF

BMS AND SOFTWARE

KPDF-90 DN2.4


INDUSTRIAL VRF RANGE INDOOR UNITS

Ducts STATIC PRESSURE GRAPHS KPDF-15 DN3.0

KPDF-22 DN3.0 - KPDF-28 DN3.0

KPDF-36 DN3.0

204


Inspiration, Innovation, Evolution

A

DC

INVERTER

R-410A

INDOOR

B

KPDF-45 DN3.0

AMAZON INDUSTRIAL VRF

KPDF-56 DN3.0

KPDF-71 DN3.0

205


INDUSTRIAL VRF RANGE INDOOR UNITS

Ducts STATIC PRESSURE GRAPHS KPDF-80 DN3.0

KPDF-90 DN3.0

206


Inspiration, Innovation, Evolution

A

DC

INVERTER

R-410A

INDOOR

B

KPDF-112 DN3.0

AMAZON INDUSTRIAL VRF

KPDF-140 DN3.0

207


INDUSTRIAL VRF RANGE INDOOR UNITS

HIGH PRESSURE DUCTS GENERAL CHARACTERISTICS As their name suggest, these duct units supply higher static pressure, which allows for a more flexible design. They adapt to every installation space, even those with very high ceilings.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226

AMAZON UNITARIO

On/Off dry contact and Alarm 220 V output.

The expansion valve is integrated inside the 16 kW models; models over 20 kW have expansion valve fitted on the side of the unit.

Compatible with AIRZONE air-conditioning zoning systems.

Units with high airflows.

Power range from 7.1 kW to 56 kW.

Units with a DC INVERTER fan motor (a power range from 7.1 kW to 28 kW).

Condensation pump not included.

Air suction filter included in the whole range.

2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

AMAZON III PRO 3 PIPES see pag. 242

TECHNICAL SPECIFICATIONS KPDHF-71 DN3.0

MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply

kW Kcal/h kW Kcal/h W m3/h Pa dB (A) mm Kg mm (inch") mm (inch") mm mm2 mm2 V / F / Hz

All AMAZON indoor units accept R-410A refrigerant.

208

KPDHF-90 DN3.0

KPDHF-112 DN3.0

KPDHF-140 DN3.0

KPDHF-160 DN3.0

7.1

9

11.2

14

16

6106

7740

9632

12040

13760

8

10

12.5

16

17

6880

8600

10750

13760

14620

180

220

380

420

700

1800/1600/1500

2200/1900/1700

2600/2200/1950

3600/3100/2800

4400/3400/3100

210

210

210

220

220

42

45

45

48

50

952/420/690

952/420/690

952/420/690

1300/420/690

1300/420/690

41

47

47

68

78

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

ø9.52 (3/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø25

Ø25

Ø25

Ø25

Ø25

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50

220-240/1/50


Inspiration, Innovation, Evolution

R-410A

+

FROM 7.1 KW TO 28 KW DC INVERTER FAN MOTORS

+

HIGH AIRFLOWS

Compatible with

KCT-02.1 SR (*) RECOMMENDED

PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.

CONTROLS

For further information, please see our Controllers Range CENTRALISED

INDIVIDUAL

KI-02.3 S

CHOOSE YOUR

CONTROLLER

KCT-02.1 SR

KC-02.1 H

KC-01 S

KCCT-64 I (B)

NEW

NEW

KCCT-64 IPS

KCCT-384 IPS

KCC-64 WEB

K01-KNX

K01-WIFI

K01-LON

K02-MODBUS

MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply

K01 MODBUS 1/4/8/32

K01-BACNET

KAYNET CONTROL

KPDHF-200 KPDHF-250 KPDHF-280 KPDHF-400 KPDHF-450 KPDHF-560 DN3.0 DN3.0 DN3.0 DN2.4 DN2.4 DN2.4 20 25 28 40 45 56 kW 17200 21500 24080 34400 38700 48160 Kcal/h 22.5 26 31.5 45 50 63 kW 19350 22360 27090 38700 43000 54180 Kcal/h 800 800 800 2700 2700 3400 W 6000/5800/5400 6000/5800/5400 6000/5800/5400 7800/6500/5500 7800/6500/5500 11000/9000/7500 m3/h 250 250 250 200 200 200 Pa 50 50 50 56 56 57 dB (A) 1443/470/810 1443/470/810 1443/470/810 1970/668/902.5 1970/668/902.5 1970/668/902.5 mm 108 108 108 232 232 235 Kg Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8") mm (inch") ø9.52 (3/8") Ø22.2 (7/8") Ø22.2 (7/8") Ø28.6 (1 1/8”) Ø28.6 (1 1/8”) Ø28.6 (1 1/8”) mm (inch) Ø22.2 (7/8") Ø32 Ø32 Ø32 Ø32 Ø32 Ø32 mm (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4 (2+T)x4 (2+T)x4 mm2 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 mm2 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50

209

AMAZON INDUSTRIAL VRF

BMS AND SOFTWARE


INDUSTRIAL VRF RANGE INDOOR UNITS

HIGH PRESSURE DUCTS STATIC PRESSURE GRAPHS KPDHF-71 DN3.0

KPDHF-90 DN3.0

KPDHF-112 DN3.0

210


Inspiration, Innovation, Evolution

R-410A

KPDHF-140 DN3.0

AMAZON INDUSTRIAL VRF

KPDHF-160 DN3.0

KPDHF-200 DN3.0

211


INDUSTRIAL VRF RANGE INDOOR UNITS

HIGH PRESSURE DUCTS STATIC PRESSURE GRAPHS KPDHF-250/280 DN3.0

KPDHF-400/450 DN2.4

212


Inspiration, Innovation, Evolution

R-410A

AMAZON INDUSTRIAL VRF

KPDHF-560 DN2.4

213


INDUSTRIAL VRF RANGE INDOOR UNITS

KAHU GENERAL CHARACTERISTICS This is an interface that allows you to connect a UTA (air terminal unit) with a direct-expansion coil to the VRF system. This unit shall be treated like an additional indoor unit within the VRF system. •

Can be installed on direct expansion batteries up to 56 Kw.

It consists of an electrical control box, electronic expansion valve, cables and control sensors.

It includes an XYE port to connect to a centralised indoor unit control.

On/Off dry contact and 220 V Alarm output.

Compatible only with 2 ducts outdoor units.

More than one unit can be connected at the same time to increase the connectable power.

COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224 226

AMAZON UNITARIO 2 PIPES see pag. 228-230-232

AMAZON IV PRO 2 PIPES see pag. 236

AMAZON III W 2 PIPES see pag. 238

TECHNICAL SPECIFICATIONS MODEL

KAHU-200.2

KAHU-360.2

KAHU-560.2

Cooling capacity*

kW

From 9 to 20

From 21 to 36

From 37 to 56

Width/Height/Depth

mm

350/375/150

350/375/150

350/375/150

Net weight

Kg

8.4

8.7

8.9

Liquid pipe diameter

mm (inch")

ø9.52 (3/8")

Ø12.7 (1/2")

Ø15.9 (5/8")

Gas pipe diameter

mm (inch")

ø9.52 (3/8")

Ø12.7 (1/2")

Ø15.9 (5/8")

Power cord (10 m max.)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

V / F / Hz

220-240/1/50

220-240/1/50

220-240/1/50

Power supply

* Power can be adjusted by a dip switch located at the electric board.

214


Inspiration, Innovation, Evolution

R-410A

1

ELECTRICAL CONTROL BOX

2

KCT-02.1 SR BUILT-IN WIRED CONTROL

KCT-02.1 SR

IBLE WI TH PAT OM

ITH

TS

C U D 2

LE W

ONL YC

STANDARD

ON LY C PATIB OM

ELECTRIC EXPANSION VALVE

4

AMAZON INDUSTRIAL VRF

3

TEMPERATURE CABLES AND SENSORS

INSTALLATION EXAMPLE KAHU OUTDOOR UNIT

PQE Liquid cooling pipeline

INDOOR UNITS

Gas cooling pipeline

MARKET CLIMATE CONTROL WITH DIRECT EXPANSION BATTERY

215


INDUSTRIAL VRF RANGE INDOOR UNITS

HOT WATER INDOOR UNIT GENERAL CHARACTERISTICS KAYSUN has an indoor unit specific for AMAZON systems that is able to produce hot water. •

For domestic hot water and heating.

Water outlet temperature between 25ºC and 45ºC.

TECHNICAL SPECIFICATIONS KWF-140 ACS

MODEL Heating capacity

kW

14

Heating Capacity

Kcal/h

12040

Power consumption

W

1

Water outlet temperature range

ºC

25-45

Working limits with cold outdoor temp.

ºC

-5ºC to 35ºC

Working limits with heat outdoor temp.

ºC

-5ºC to 35ºC

Water inlet pipe diameter

Inches

DN25

Water outlet pipe diameter

Inches

DN25

Design airflow

m³/h

2.4 (from 2 to 3)

Inlet liquid pipe diameter

mm (inch")

ø9.52 (3/8")

Outlet liquid pipe diameter

mm (inch")

Ø15.9 (5/8")

dB (A)

26

Width/Height/Depth

mm

500/900/373

Net weight

Kg

55

Sound pressure

Power cord (10 m max.)

mm

2

Shielded communication wires

mm

2

Power supply

216

V / F / Hz

(2+T)x2.5 3x0.75 220-240/1/50


Inspiration, Innovation, Evolution

R-410A

+

DOMESTIC HOT WATER

INSTALLATION EXAMPLE AMAZON III PRO 3 PIPES OUTDOOR UNIT

AMAZON INDUSTRIAL VRF

DOMESTIC HOT WATER RECOVERY KIT

KVBM2-DN3

KVBM2-DN3 DOMESTIC HOT WATER

INDOOR UNIT

217


INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

218


Inspiration, Innovation, Evolution

OUTDOOR UNITS

AMAZON INDUSTRIAL VRF

TECHNICAL SPECIFICATIONS

219


INDUSTRIAL VRF RANGE OUTDOOR UNITS

OUTDOOR UNITS RANGE 2 PIPES

POWER kW

8.0

10.5

12.0

14.0

16.0

18.0

KMF-105 DVN3

KMF-120 DVN2

KMF-140 DVN2

KMF-160 DVN2

KMF-120 DTN2

KMF-140 DTN2

KMF-160 DTN2

KMF-180 DTN2

25.2

26.0

28.0

33.5

K2UF-280 DN3

K2UF-335 DN3

K2UF-280 DN4 S

K2UF-335 DN4 S

MINI AMAZON II SINGLE-PHASE (Page 224)

FULL DC INVERTER

KMF-80 DVN3

THREE-PHASE (Page 226)

POWER kW

20.0

22.4

AMAZON UNITARIO FRONT AIR DISCHARGE (Page 228)

FULL DC INVERTER

KMF-200 DN2

KMF-224 DN2

TOP DISCHARGE DN3 (Page 230)

UNTIL END OF STOCK

NEW

(Page 232)

TOP DISCHARGE DN4 S

KMF-260 DN2

FULL DC INVERTER

AMAZON IV PRO

COMBINABLE UP TO 4 MODULES

(Page 236)

FULL DC INVERTER

K2F-252 DN4 S

AMAZON III W

K2F-280 DN4 S

COMBINABLE UP TO 3 MODULES

(Page 238) K2F-252 DN3W

3 PIPES

POWER kW

20.0

AMAZON III PRO FULL DC INVERTER

220

K2F-335 DN4 S

22.4

25.2

26.0

K2F-280 DN3W

K2F-335 DN3W

28.0

33.5

COMBINABLE UP TO 4 MODULES

(Page 242) K3F-252 DN3 S

K3F-280 DN3 S

K3F-335 DN3 S


Inspiration, Innovation, Evolution

22.4

25.2

26.0

28.0

33.5

40.0

50.0

56.0

61.5

67.0

73.0

K2UF-560 DN3

K2UF-615 DN3

K2UF-670 DN3

K2UF-560 DN4 S

K2UF-615 DN4 S

40.0

45.0

KMF-400 DN3

KMF-450 DN3

K2UF-400 DN3

K2UF-450 DN3

K2UF-400 DN4 S

K2UF-450 DN4 S K2UF-500 DN4 S

K2F-400 DN4 S

K2F-450 DN4 S

K2F-500 DN4 S

K2F-560 DN4 S

K2F-615 DN4 S

40.0

45.0

50.0

56.0

61.5

K3F-400 DN3 S

K3F-450 DN3 S

K2UF-670 DN4 S K2UF-730 DN4 S

45.0

78.5

K2UF-785 DN4 S

50.0

56.0

85.0

90.0

K2UF-850 DN4 S K2UF-900 DN4 S

AMAZON INDUSTRIAL VRF

20.0

67.0

73.0

78.5

85.0

90.0

221


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

VRF OUTDOOR UNITS

2 PIPES

AMAZON IV PRO KAYSUN continues to focus on its AMAZON IV PRO range. All the compressors and fans of this range are DC INVERTER, a feature that turns this new model into a FULL DC INVERTER. Furthermore, unlike previous ranges, these units are fitted with 2 additional modules, thereby allowing for more combinations. Now we have 8 modules from 8HP to 22HP, which are available to combine up to 88 HP (4 modules maximum). We would like to highlight this range's novel and dynamic design , unique on the market, which compared to previous models, allows for installing the units in smaller spaces according to their capacity. As is always the case, depending on the type of combination, the units of this new range allow us to connect up to 64 indoor units. However, some of the most outstanding features of previous models have been kept for this new range, such as: Delta-shaped heat exchangers that enhance subcooling and allow for longer installation distances self-addressing function, up to 150% simultaneity, silent ventilation and 40Pa available pressure in fans.

+

FULL DC INVERTER

AMAZON UNITARIO

NEW

222

AMAZON UNITARIO, the KAYSUN range of non-combinable units, has units with 28kW to 90 kW top discharge and up to 40Pa available pressure, and 5 front air discharge units from 20kW to 45kW. This INVERTER technology single solution of KAYSUN allows for combining up to 53 indoor units and a 200 metres maximum installation distance between the outdoor unit and the furthest indoor unit. This unit also provides a 150% simultaneity, highly efficient compressors and a silent ventilation system and a rotary electric box. This is a very thorough and competitive product.


MINI AMAZON II

AMAZON III W

The MINI AMAZON II generation with 2 ducts, DC Inverter compressor and fan motor keeps its 9 models. The design of fan´s blades and grille, as well as the DC Inverter technology used therein and in the “Twin Rotary“ compressor motor, provides the unit with outstanding energy efficiency and work range. KAYSUN seeks to provide versatility and total freedom, adding up to 9 indoor units to the combinations of the Mini AMAZON range and expanding the cooling distances up to 60 meters of actual overall length. Outdoor units automatically distribute the address to indoor units with no manual adjustment. In addition, 12, 14, 16 and 18 kW can be installed in 4 different positions, thereby making installation easier. Moreover, the XYE port in the outdoor unit's board allows for the connection of the centralised control panel of indoor unit directly to the outdoor unit.

The new AMAZON III W range of 2 water condensed pipes with DC INVERTER compressors stands out from the whole range because of its modular design, which supports combinations up to 36 HP through the combination of 3 basic modules of 8-1012 HP with which you can install up to a maximum of 59 indoor units. The structure of the new unit is much more compact and lightweight compared to the AMAZON air-condensed outdoor units. Thanks to its small size and the possibility of vertical installation (one outdoor on top of the other due to the lack of fans) allows it to be installed in very tight spaces. The lack of fans obviously reduces the sound pressure levels of outdoor units. Furthermore, due to the savings on consumption resulting from the lack of fans, energy efficiency notably increases if compared to the AMAZON air-condensed system, making it one of the strengths of the AMAZON III W.

MULTIPLE COMBINATIONS The AMAZON range offers a wide variety of installation possibilities from 9 types of indoor units with different ranges of cooling power, thereby allowing for the installation of 64 indoor units maximum, depending on the outdoor unit model or combinations thereof. This combination flexibility allows it to adapt to a wide variety of projects. One solution for every single need. Kaysun's VRF system allows for installations with 50 % to 150% simultaneity.

64

UP TO 64 INDOOR UNITS

OUTDOOR UNIT

INDOOR UNITS

Wall

Double flow console

Art flux 360º cassette

Floor with wraparound

Duct

High pressure duct

SYSTEMS WITH LONG DISTANCE COOLING PIPELINES AMAZON equipment allows for designing and arranging an entire cooling and heating system with greater flexibility. The planning and design difficulty inherent to air-conditioning projects in complex or large buildings are made simple thanks to the long pipes distance and height provided by our range of products.

223

AMAZON INDUSTRIAL VRF

Inspiration, Innovation, Evolution


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

MINI AMAZON II SINGLE-PHASE

2 PIPES

TECHNICAL SPECIFICATIONS KMF-80 DVN3 KMF-105 DVN3 KMF-120 DVN2 KMF-140 DVN2 KMF-160 DVN2

MODEL Cooling capacity

kW

7.2

9.0

12.3

14.0

15.5

Cooling capacity

Kcal/h

6880

8600

10578

12040

13330

Cooling input

kW

1.85

2.30

3.25

3.95

4.52

Heating Capacity

kW

8.4

10.5

13.2

15.4

17.00

Heating Capacity

Kcal/h

7224

9030

11352

13244

14620

kW

1.79

2.27

3.47

4.16

4.77

EER

3.90

3.92

3.78

3.54

3.43

COP Amount of connectable indoor units Power supply

4.02

3.97

3.80

3.70

3.56

4

5

6

6

7

220-240 / 1 / 50

220-240 / 1 / 50

220-240 / 1 / 50

220-240 / 1 / 50

220-240 / 1 / 50

Inverter compressor

1

1

1

1

1

Fans

1

1

2

2

2

mm (Inch)

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

mm (inches)

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø19.1 (3/4")

R-410A

R-410A

R-410A

R-410A

R-410A

gr

2800

2950

3300

3900

3900

Air flow

m3/h

3600

5100

6000

6000

6000

Width/Height/Depth

mm

990/966/336

990/966/336

900/1327/320

900/1327/320

900/1327/320

Net weight

Kg

62

72

95

95

100

Sound pressure

dB (A)

56

57

54

54

54

Power cord (under 20 metres)

mm2

(2+T)x2.5

(2+T)x4

(2+T)x4

(2+T)x6

(2+T)x6

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-15 to 43

-15 to 43

-15 to 43

-15 to 43

-15 to 43

Heating operation range

-15 to 27

-15 to 27

-15 to 27

-15 to 27

-15 to 27

Heating input

Liquid pipe diameter Gas pipe diameter

V / F / Hz

Refrigerant Refrigerant charging

BRANCH PIPES MODEL KCMI 112

224

(FRG100 + FRG200)


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

!

DC

INVERTER

OUTDOOR

GENERAL CHARACTERISTICS The Mini Amazon II system is ideal to meet the needs in small industrial environments. Its air condensed 2 pipe direct-expansion technology covers a range of cooling capacities from 8 up to 16 kW in single phase models. •

Depending on the model, single-phase units accept up to 7 indoor units.

It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

Since it is fitted with horizontal air discharge, it does not require much space for installation or maintenance.

The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.

Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.

It includes a self-addressing feature for indoor units.

The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.

The cooling pipeline of 12, 14 and 16kW models may be installed in 4 different positions, thereby facilitating their installation.

Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

+

ErP

8 / 10.5

+

AMAZON INDUSTRIAL VRF

12 / 14 / 16

DC INVERTER COMPRESSOR AND FAN

UP TO 7 INDOOR UNITS

225


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

MINI AMAZON II THREE-PHASE

2 PIPES

TECHNICAL SPECIFICATIONS KMF-120 DTN2

MODEL

KMF-140 DTN2

KMF-160 DTN2

KMF-180 DTN2

Cooling capacity

kW

12.3

14.0

15.5

17.5

Cooling capacity

Kcal/h

10578

12040

13330

15050

Cooling input

kW

3.25

4.08

4.52

5.60

Heating Capacity

kW

13.2

15.4

17.0

19.0

Heating Capacity

Kcal/h

11352

13244

14620

16340

kW

3.47

4.12

4.77

5

EER

3.78

3.54

3.43

3.30

COP

3.80

3.70

3.56

3.80

6

6

7

9

380-400 / 3 / 50

380-400 / 3 / 50

380-400 / 3 / 50

380-400 / 3 / 50

Inverter compressor

1

1

1

1

Fans

2

2

2

2

mm (Inch)

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

mm (inches)

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø19.1 (3/4")

Ø19.1 (3/4")

R-410A

R-410A

R-410A

R-410A

gr

3300

3900

3900

4500

Air flow

m3/h

6000

6000

6000

6800

Width/Height/Depth

mm

900/1327/320

900/1327/320

900/1327/320

900/1327/320

Net weight

Kg

95

95

102

107

Sound pressure

dB (A)

57

57

57

59

Power cord (under 20 metres)

mm2

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-15 to 43

-15 to 43

-15 to 43

-15 to 43

Heating operation range

-15 to 27

-15 to 27

-15 to 27

-15 to 27

Heating input

Amount of connectable indoor units Power supply

Liquid pipe diameter Gas pipe diameter

V / F / Hz

Refrigerant Refrigerant charging

BRANCH PIPES MODEL KCMI 112

226

(FRG100 + FRG200)


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

!

DC

INVERTER

OUTDOOR

GENERAL CHARACTERISTICS The Mini Amazon II system is ideal to meet the needs in small industrial environments. Its air condensed 2 pipe direct-expansion technology covers a range of cooling capacities from 12 up to 18 kW in three phase models. •

Depending on the model, three-phase units accept up to 9 indoor units.

It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

Since it is fitted with horizontal air discharge, it does not require much space for installation or maintenance.

The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.

Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.

It includes a self-addressing feature for indoor units.

The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.

The cooling pipeline of 12, 14, 16 and 18 kW models may be installed in 4 different positions, thereby facilitating their installation.

Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

+ +

AMAZON INDUSTRIAL VRF

12 / 14 / 16 / 18

DC INVERTER COMPRESSOR AND FAN

UP TO 12 INDOOR UNITS

227


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

AMAZON UNITARIO

FRONT AIR DISCHARGE

TECHNICAL SPECIFICATIONS KMF-200 DN2 KMF-224 DN2 KMF-260 DN2 KMF-400 DN3 KMF-450 DN3

MODEL Cooling capacity

kW

20.0

22.4

26.0

40.0

45.0

Cooling capacity

Kcal/h

17200

19264

22360

34400

38700

Cooling input power

kW

6.10

6.80

7.60

11.90

13.60

Heating capacity

kW

22.0

24.5

28.5

45.0

50.0

Heating capacity

Kcal/h

18920

21070

24510

38700

43000

kW

6.10

5.90

6.80

11.10

12.70

EER

3.28

3.29

3.42

3.35

3.32

COP

3.61

4.15

1.19

4.05

3.93

10

11

12

14

15

380-400 / 3 / 50

380-400 / 3 / 50

380-400 / 3 / 50

380-400 / 3 / 50

380-400 / 3 / 50

Inverter compressors

1

1

1

2

2

Fans

2

2

2

2

2

Heating input power

Amount of connectable indoor units Power supply

V / F / Hz

Liquid pipe diameter

mm (Inch)

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø12.7 (1/2")

Ø12.7 (1/2")

Gas pipe diameter

mm (Inch)

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø22.2 (7/8")

Ø22.2 (7/8")

Ø25.4 (1")

R-410A

R-410A

R-410A

R-410A

R-410A

gr

4800

6200

6200

9000

12000

Airflow

m3/h

10999

10494

10494

16575

16575

Width/Height/Depth

mm

1120/1558/400

1120/1558/400

1120/1558/400

1360/1650/540

1360/1650/540

Net weight

Kg

137

146

147

240

275

Sound pressure

dB (A)

59

59

60

62

62

Power cord (under 20 metres)

mm2

(4+T)x2.5

(4+T)x2.5

(4+T)x2.5

(4+T)x10

(4+T)x16

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-15 to 46

-15 to 46

-15 to 46

-5 to 48

-5 to 48

Heating operation range

-15 to 24

-15 to 24

-15 to 24

-15 to 24

-15 to 24

Refrigerant Refrigerant charging*

BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)

228


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

!

DC

INVERTER OUTDOOR

GENERAL CHARACTERISTICS The AMAZON UNITARIO SIDE AIR DISCHARGE range has non-combinable external VRF units between 20 kW and 45 kW. The big advantage of these units is the possibility to install higher power equipments in confined spaces. •

Depending on the model, they accept up to 15 indoor units.

It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

Night mode is included as an option in order to reduce the sound level of outdoor units.

It includes a self-addressing feature for indoor units.

Since it is fitted with front air discharge, it does not require much space for installation or maintenance.

The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.

The entire range works only with Twin Rotary DC Inverter compressors and DC Inverter fans, which provides it with remarkable energy efficiency and low consumption and sound levels.

Up to 120 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

+ +

AMAZON INDUSTRIAL VRF

20 / 22 / 26 / 40 / 45

UP TO 15 INDOOR UNITS

INVERTER COMPRESSORS AND FANS

229


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

AMAZON UNITARIO

TOP DISCHARGE DN3

UNTIL END OF STOCK

TECHNICAL SPECIFICATIONS K2UF-280 DN3

MODEL

K2UF-335 DN3

K2UF-400 DN3

K2UF-450 DN3

K2UF-560 DN3

K2UF-615 DN3

K2UF-670 DN3

Capacity

HP

10

12

14

16

20

22

24

Cooling capacity

kW

28

33.5

40

45

56

61.5

67

Cooling capacity

Kcal/h

24080

28810

34400

38700

48160

52890

57620

Cooling input

kW

7.19

9.05

12.30

14.01

17.00

18.80

20.80

Heating Capacity

kW

32

37.5

45

50

63

69

75

Heating Capacity

Kcal/h

27090

32250

38700

43000

54180

59340

64500

kW

7.60

8.99

11.20

12.80

16.00

17.90

19.80

EER

3.89

3.70

3.25

3.21

3.30

3.27

3.22

COP

4.14

4.17

4.02

3.91

3.94

3.86

3.79

16

16

16

20

33

36

39

380 / 3 / 50

380 / 3 / 50

380 / 3 / 50

380 / 3 / 50

380 / 3 / 50

380 / 3 / 50

380 / 3 / 50

Inverter compressor

1

1

1

1

1

1

1

Fixed Scroll compressors

0

1

2

2

2

2

2

Fans

1

2

2

2

2

2

2

Heating input

Amount of connectable indoor units Power supply

V / F / Hz

Liquid pipe diameter

mm (Inch)

Ø12.7 (1/2")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø19.1 (3/4")

Gas pipe diameter

mm (Inch)

Ø25.4 (1")

Ø31.8 (1 1/4")

Ø31.8 (1 1/4")

Ø31.8 (1 1/4")

Ø31.8 (1 1/4")

Ø31.8 (1 1/4")

Ø31.8 (1 1/4")

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

gr

10000

12000

15000

15000

17000

18500

18500

m3/h

11,000

15,000

15,000

15,000

18,000

22,100

22,100

Pa

40

40

40

40

40

40

40

Refrigerant Refrigerant charging Air flow Static Pressure Width/Height/Depth

mm

Net weight

Kg

205

275

325

325

360

385

390

Sound pressure

dB (A)

58

58

60

60

62

63

63

Power cord (under 20 metres)

mm2

(4+T)*4

(4+T)*6

(4+T)*10

(4+T)*16

(4+T)*16

(4+T)*25

(4+T)*25

Communication wiring

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-5 to 48

-5 to 48

-5 to 48

-5 to 48

-5 to 48

-5 to 48

-5 to 48

Heating operation range

-15 to 24

-15 to 24

-15 to 24

-15 to 24

-20 to 27

-20 to 27

-20 to 27

BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)

230

960/1615/765 1250/1615/765 1250/1615/765 1250/1615/765 1390/1615/765 1585/1615/765 1585/1615/765


Inspiration, Innovation, Evolution

R-410A

!

GENERAL CHARACTERISTICS Direct-expansion system for 2 air-condensed pipes designed for 28 kW to 67 kW cooling power units. It is ideal for airconditioning large spaces that require the creation of atmospheres with different temperatures. Inverter fan.

Individual (non-combinable) outdoor units with capacity ranging from 10 to 24 hp (7 models). This system is able to combine between 16 and 39 indoor units.

Night mode is included as an option in order to reduce the sound level of outdoor units.

It admits a 50% to 150% simultaneity index of the outdoor unit's power.

Highly-efficiency scroll and fixed DC Inverter compressors with environmentally friendly R410A refrigerant.

Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC

Up to 175 metres of actual length for the pipes connecting the outdoor unit with the farthest indoor unit.

+ +

AMAZON INDUSTRIAL VRF

UP TO 39 INDOOR UNITS

NON-COMBINABLE SYSTEMS

231


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

AMAZON UNITARIO

TOP DISCHARGE DN4 S

NEW

TECHNICAL SPECIFICATIONS MODEL

K2UF-280 DN4 S

K2UF-335 DN4 S

K2UF-400 DN4 S

K2UF-450 DN4 S

Capacity

HP

10

12

14

16

Cooling capacity

kW

28

33.5

40

45

Cooling capacity

Kcal/h

24080

28810

34400

38700

Cooling input

kW

6.7

8.9

11.0

12.9

Heating Capacity

kW

28

33.5

40

45

Heating Capacity

Kcal/h

24080

28810

34400

38700

kW

5.5

7.6

9.3

10.7

EER

4.20

3.75

3.65

3.50

COP

5.10

4.40

4.30

4.20

16

20

23

26

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

Inverter compressor

1

1

1

1

Fans

1

1

1

1

Heating input

Amount of connectable indoor units Power supply

V / F / Hz

Liquid pipe diameter

mm (Inch)

ø12.7 (1/2")

ø15.9 (5/8")

ø15.9 (5/8")

ø15.9 (5/8")

Gas pipe diameter

mm (Inch)

ø25.4 (1")

ø28.6 (1 1/8")

ø31.8 (1 1/4")

ø31.8 (1 1/4")

R-410A

R-410A

R-410A

R-410A

gr

11000

11000

13000

13000

m3/h

11000

11000

13000

13000

Pa

60

60

60

60

Width/Height/Depth

mm

990/1635/790

990/1635/790

1340/1635/850

1340/1635/850

Net weight

Kg

227

227

277

277

Sound pressure

dB (A)

58

60

62

65

Power cord (under 20 metres)

mm2

(4+T)*4

(4+T)*6

(4+T)*10

(4+T)*16

Shielded communication wires

mm

3x0.75

3x0.75

3x0.75

3X0.75

Cooling operation range

-5 to 48

-5 to 48

-5 to 48

-5 to 48

Heating operation range

-23 to 24

-23 to 24

-23 to 24

-23 to 24

Refrigerant Refrigerant charging Air flow Static Pressure

BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)

232

2


Inspiration, Innovation, Evolution

DC

K2UF-500 DN4 S

MODEL

K2UF-560 DN4 S

K2UF-615 DN4 S

!

INVERTER

DC

INVERTER

OUTDOOR

K2UF-670 DN4 S

Capacity

HP

18

20

22

24

Cooling capacity

kW

50

56

61.5

67

Cooling capacity

Kcal/h

43000

48160

52890

57620

Cooling input

kW

14.7

16.0

20.2

21.6

Heating Capacity

kW

50

56

62

67

Heating Capacity

Kcal/h

43000

48160

52890

57620

kW

12.2

13.8

17.6

16.8

EER

3.40

3.50

3.05

3.10

COP

4.10

4.05

3.50

4.00

29

33

36

39

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

Inverter compressor

1

2

2

2

Fans

1

2

2

2

Heating input

Amount of connectable indoor units Power supply

V / F / Hz

Liquid pipe diameter

mm (Inch)

ø19.1 (3/4")

ø19.1 (3/4")

ø19.1 (3/4")

ø19.1 (3/4")

Gas pipe diameter

mm (Inch)

ø31.8 (1 1/4")

ø31.8 (1 1/4")

ø31.8 (1 1/4")

ø31.8 (1 1/4")

R-410A

R-410A

R-410A

R-410A

gr

13000

17000

17000

22000

m3/h

13000

17000

17000

25000

Pa

60

60

60

60

Width/Height/Depth

mm

1340/1635/850

1340/1635/825

1340/1635/825

1730/1830/850

Net weight

Kg

295

348

348

430

Sound pressure

dB (A)

65

66

66

67

Power cord (under 20 metres)

mm2

(4+T)*16

(4+T)*16

(4+T)*25

(4+T)*25

Shielded communication wires

mm

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-5 to 48

-5 to 48

-5 to 48

-5 to 48

Heating operation range

-23 to 24

-23 to 24

-23 to 24

-23 to 24

Refrigerant Refrigerant charging Air flow Static Pressure

2

BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)

233

AMAZON INDUSTRIAL VRF

R-410A


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

AMAZON UNITARIO TOP DISCHARGE DN4 S

NEW

TECHNICAL SPECIFICATIONS K2UF-730 DN4 S

MODEL

K2UF-785 DN4 S

K2UF-850 DN4 S K2UF-900 DN4 S

Capacity

HP

26

28

30

32

Cooling capacity

kW

73

78.5

85

90

Cooling capacity

Kcal/h

62780

67510

73100

77400

Cooling input

kW

21.6

24.9

28.3

32.1

Heating Capacity

kW

73.0

78.5

85.0

90.0

Heating Capacity

Kcal/h

62780

67510

73100

77400

kW

18.1

21.8

24.3

26.5

EER

3.40

3.15

3.00

2.80

COP

4.05

3.60

3.50

3.40

43

46

50

53

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

Inverter compressor

2

2

2

2

Fans

2

2

2

2

Heating input

Amount of connectable indoor units Power supply

V / F / Hz

Liquid pipe diameter

mm (Inch)

ø22.2 (7/8")

ø22.2 (7/8")

ø22.2 (7/8")

ø22.2 (7/8")

Gas pipe diameter

mm (Inch)

ø31.8 (1 1/4")

ø31.8 (1 1/4")

ø38.1 (1”-1/2)

ø38.1 (1”-1/2)

R-410A

R-410A

R-410A

R-410A

gr

22000

22000

25000

25000

m3/h

25000

25000

24000

24000

Pa

60

60

60

60

Width/Height/Depth

mm

1730/1830/850

1730/1830/850

1730/1830/850

1730/1830/850

Net weight

Kg

429

429

475

475

Sound pressure

dB (A)

68

68

68

68

Power cord (under 20 metres)

mm2

(4+T)*25

(4+T)*25

(4+T)*25

(4+T)*25

Shielded communication wires

mm

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-5 to 48

-5 to 48

-5 to 48

-5 to 48

Heating operation range

-23 to 24

-23 to 24

-23 to 24

-23 to 24

Refrigerant Refrigerant charging Air flow Static Pressure

BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)

234

2


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

!

DC

INVERTER

OUTDOOR

GENERAL CHARACTERISTICS Direct-expansion system for 2 air-condensed pipes designed for 28 kW to 90 kW cooling power units. It is ideal for airconditioning large spaces that require the creation of atmospheres with different temperatures. •

Individual (non-combinable) outdoor units with capacity ranging from 10 to 32 hp. This system is able to combine between 16 and 53 indoor units.

It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.

This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units even more efficient than previous models.

Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

They include a gas-to-gas heat exchanger. When is is in Cooling mode, it improves refrigerant subcooling; when it is in Heating mode, it improves units’ performance by steam injection.

Night mode is included as an option in order to reduce the sound level of outdoor units.

10 / 12

14 / 16 / 18 / 20 / 22

NEW

NEW

AMAZON INDUSTRIAL VRF

24 / 26 / 28 / 30 / 32

NEW

+

FULL DC INVERTER

+

NON-COMBINABLE SYSTEMS

235


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

AMAZON IV PRO

2 PIPES

TECHNICAL SPECIFICATIONS K2F-252 DN4 S

MODEL

K2F-280 DN4 S

K2F-335 DN4 S

K2F-400 DN4 S

K2F-450 DN4 S

K2F-500 DN4 S

K2F-560 DN4 S

K2F-615 DN4 S

Capacity

HP

8

10

12

14

16

18

20

22

Cooling capacity

kW

25.2

28

33.5

40

45

50

56

61.5

Cooling capacity

Kcal/h

21672

24080

28810

34400

38700

43000

48160

52890

Cooling input power

kW

6.25

7.49

8.91

11.66

13.64

14.71

16.47

19.84

Heating Capacity

kW

27

31.5

37.5

45

50

56

63

69

Heating Capacity

Kcal/h

23220

27090

32250

38700

43000

48160

54180

59340

kW

5.30

6.89

8.91

9.83

11.69

12.50

14.00

16.18

EER

4.03

3.74

3.76

3.43

3.30

3.40

3.40

3.10

COP

5.09

4.57

4.21

4.07

3.85

4.00

4.00

3.80

13

16

19

23

26

29

33

36

Heating input

Amount of connectable indoor units Power supply

V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50

Inverter compressor

1

1

1

2

2

2

2

2

Fans

1

1

1

2

2

2

2

2

Oil balance pipe diameter

mm (Inch) Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Liquid pipe diameter

mm (Inch) Ø9.53 (3/8")

Ø9.53 (3/8")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Gas pipe diameter

mm (Inch) Ø22.2 (7/8")

Ø22.2 (7/8")

Ø25.4 (1")

Ø25.4 (1")

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

R-410A

gr

9000

9000

11000

13000

13000

13000

16000

16000

m3/h

12000

12000

12000

14000

14000

16000

16000

16000

Pa

40

40

40

40

40

40

40

40

Refrigerant Refrigerant charging Air flow Static Pressure

Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8")

Width/Height/Depth

mm

Net weight

Kg

219

219

237

297

297

305

340

dB (A)

58

59

60

62

62

63

63

Sound pressure

990/1635/790 990/1635/790 990/1635/790 1340/1635/7901340/1635/7901340/1635/7901340/1635/7901340/1635/790 340 63

33

Power cord (under 20 metres)

mm2

(4+T)x2.5

(4+T)x4

(4+T)x6

(4+T)x10

(4+T)x16

(4+T)x16

(4+T)x16

(4+T)x16

Communication wiring

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

Heating operation range

BRANCH PIPES MODEL

From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -20 to 24

From -20 to 24

From -20 to 24

From -20 to 24

MODEL KCME 12

KCMI 212 (FRG100+FRG300)

KCME 13

KCMI 312 (FRG200+FRG300)

KCME 14

KCMI 512 (FRG300+FRG500)

236

From -20 to 24

From -20 to 24

From -20 to 24

OUTDOOR MODULES T-TYPE BRANCH PIPES

KCMI 112 (FRG100+FRG200)

KCMI 412 (FRG200+FRG400)

From -20 to 24


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

!

DC

INVERTER

OUTDOOR

GENERAL CHARACTERISTICS Direct-expansion system for 2 air-condensed pipes designed for 25.2 kW to 246 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments.

This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units even more efficient than previous models. The new design of the fan's blades and protection grille reduces sound levels and increase airflow. Modular design with the option of combining the 8 individual modules (8-1012-14-16-18-20 and 22 hp) up to 88 hp (4 modules maximum).

The 12, 20 and 22 HP models are smaller if compared to previous versions because we use an extra 21% of heat exchanger's surface.

Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.

C

ON

YOUR SE

TI

CHO O

8 / 10 / 12

OMBI NA

They allow for combinations containing up to 64 indoor units.

It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.

Delta-shaped heat exchanger; it enhances subcooling values up to 12ºC and improves the exchanger's efficiency.

Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

AMAZON INDUSTRIAL VRF

14 / 16 / 18 / 20 / 22

+ +

FULL DC INVERTER

UP TO 64 INDOOR UNITS

237


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES

AMAZON III W

2 PIPES

TECHNICAL SPECIFICATIONS K2F-252 DN3W

MODEL

K2F-280 DN3W

K2F-335 DN3W

Capacity

HP

8

10

12

Cooling capacity

kW

25.2

28

33.5

Cooling capacity

Kcal/h

21672

24080

28810

Cooling input

kW

4.8

6.1

8

Heating Capacity

kW

27

31.5

37.5

Heating Capacity

Kcal/h

23220

27090

32250

kW

4.5

5.8

7.8

EER

5.25

4.59

4.19

COP

6.07

5.40

4.81

13

16

19

380-415/3/50

380-415/3/50

380-415/3/50

Inverter compressor

1

1

1

Heat exchanger type

Pipe in pipe

Pipe in pipe

Pipe in pipe

Heating input

Amount of connectable indoor units Power supply

V / F / Hz

Water flow rate

m3/h

5.4

6.0

7.2

Load loss

kPa

35

40

48

Water pipe max. pressure

Mpa

1.98

1.98

1.98

Water inlet pipe diameter

DN32

DN32

DN32

Water outlet pipe diameter

DN32

DN32

DN32

Oil balance pipe diameter

mm (Inch)

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Liquid pipe diameter

mm (Inch)

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø15.9 (5/8")

Gas pipe diameter

mm (Inch)

Ø25.4 (1")

Ø25.4 (1")

Ø31.8 (1 1/4")

R-410A

R-410A

R-410A

Refrigerant Refrigerant charging

gr

2000

2000

2000

Width/Height/Depth

mm

780/1000/550

780/1000/550

780/1000/550

Net weight

Kg

146

146

146

Sound pressure

dB (A)

51.0

52.0

52.0

Power cord (under 20 metres)

mm2

(4+T)x2.5

(4+T)x4

(4+T)x6

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

Water inlet temperature range

From 7 to 45

From 7 to 45

From 7 to 45

BRANCH PIPES MODEL

OUTDOOR MODULES T-TYPE BRANCHES MODEL

KCMI 112 (FRG100+FRG200)

KCME 12

KCMI 212 (FRG100+FRG300)

KCME 13

KCMI 312 (FRG200+FRG300)

KCME 14

KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)

238


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

GENERAL CHARACTERISTICS Direct-expansion system for 2 air condensed pipes designed for 25.2 kW to 100.5 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments. • It admits a 50 % to 150 % simultaneity index of the outdoor unit's power. • Because of the lack of fans, this system is more efficient that air-condensed systems and provides low consumption and sound levels. • Compared to previous air-condensed outdoor units, this outdoor unit is more compact and lightweight and provides a significant reduction in weight, area and volume. • Up to 150 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

C

ON

AMAZON INDUSTRIAL VRF

YOUR SE

TI

CHO O

• This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units a very efficient product. • Modular design with the option of combining the 3 individual modules (8-10-12 hp) up to 36 hp (3 modules maximum). • Shell and tube heat exchanger and highly-efficient cross airflow. • Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves. • They allow for combinations containing up to 59 indoor units.

OMBI NA

CONDENSED BY WATER

+

UP TO 59 INDOOR UNITS

239


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 3 PIPES

VRF OUTDOOR UNITS

3 PIPES

3 DUCTS AMAZON III PRO • • • • • •

5 available modules from 25,2 kW to 45 kW Up to 4 combinable modules (180 kW) Up to 64 combinable indoor units Optimized fan design Better energy efficiency Working range between -5ºC and 48ºC in cooling mode and between -20ºC and 24ºC in heating mode.

• New ventilation system One fan with 3 blades and a second fan with 4 blades

• DOUBLE SUBCOOLING: Condenser interchanger in delta form • Subcooling takes place in exchanger.

1000 m LONG DISTANCE COOLING PIPES

CONTINUOUS HEATING during defrosting • AMAZON III PRO Full DC Inverter

FULL DC INVERTER

• Compact and lightweight • Easy transport and installation. • Rotating electrical box

CONTINUOUS HEATING DURING DEFROSTING Thanks to the double condenser, the first performs the defrosting process first, then the second, thus maintaining the indoor units in heating mode during the entire process. At the same time, the unit can work with a single condenser to compensate for the highest load of the system both in cold and heat, which represents substantial energy savings and remarkable energy efficiency in the cooling circuit.

DOUBLE SUBCOOLING AMAZON III PRO 3 pipes has a dual system of liquid subcooling that increases the system's energy efficiency. The delta-shaped heat exchanger shouldreduce its load loss by increasing liquid proportion and therefore, arranging longer pipeline lengths. Thanks to this subcooling technology, liquid temperatures at the condenser outlet may reach up to 37.1ºC.

Subcooling 49 - 43 = 6ºC

OPTIMISED FAN DESIGN

Subcooling 49 - 37.1 = 12ºC

The second stage of the subcooling process is carried out in each series inverter box since, thanks to a small liquid bypass pipe, subcooling temperature may reach 22.1ºC.

New ventilation system: one fan fitted with 3 blades and a second fan fitted with 4 blades. This reduces the effect of acoustic resonance that directly affects the noise level of the outdoor unit. MAINTENANCE

Subcooling pipe

Thanks to the rotary electrical box, the cooling circuit can be accessed more easily for maintenance and installation. At the same time, the electrical box is fitted with an inspection window at the electronic board to check any malfunction without disassembling it.

240


Inspiration, Innovation, Evolution

INVERTER BOX SIMULTANEITY BETWEEN HEAT AND COLD

INVERTER BOX MULTIGROUP Available in versions of 2, 4 and 6 outputs, they support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model (see table in the AMAZON III PRO Inverter Box section). Each output can work in a different mode.

241

AMAZON INDUSTRIAL VRF

Thanks to the series inverter boxes, the system is capable of providing heat and cold simultaneously, generating heat recovery in the system and therefore overall energy savings.


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 3 PIPES

AMAZON III PRO

3 PIPES

TECHNICAL SPECIFICATIONS K3F-252 DN3S K3F-280 DN3S K3F-335 DN3S K3F-400 DN3S K3F-450 DN3S

MODEL Capacity

HP

8

10

12

14

16

Cooling capacity

kW

25.2

28

33.5

40

45

Cooling capacity

Kcal/h

21,672

24,080

28,810

34,400

38,700

Cooling input

kW

5.73

6.67

8.07

11.3

13.24

Heating Capacity

kW

27

31.5

37.5

45

50

Heating Capacity

Kcal/h

23220

27090

32250

38700

43000

kW

Heating input

6.00

7.33

8.72

11.19

12.79

EER

4.40

4.20

4.15

3.54

3.40

COP

4.50

4.30

4.30

4.02

3.91

Amount of connectable indoor units Power supply

V / F / Hz

Inverter compressor Fans

13

16

20

23

26

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

380-415 / 3 / 50

1

1

1

2

2

2

2

2

2

2

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø6.4 (1/4")

Ø12.7 (1/2")

Ø12.7 (1/2")

Ø15.9 (5/8")

Ø15.9 (5/8")

Oil balance pipe diameter

mm (Inch)

Ø6.4 (1/4")

Liquid pipe diameter

mm (Inch)

Ø9.53 (3/8")

High presure gas pipe diameter

mm (Inch)

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø22.2 (7/8")

Ø22.2 (7/8")

Low pressure gas pipe diameter

mm (Inch)

Ø22.2 (7/8")

Ø22.2 (7/8")

Ø25.4 (1")

Ø28.6 (1 1/8")

Ø28.6 (1 1/8")

Oil balance pipe diameter high-pressure gas

mm (Inch)

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø19.1 (3/4")

Ø19.1 (3/4")

R-410A

R-410A

R-410A

R-410A

R-410A

gr

10000

10000

10000

13000

13000

m3/h

12000

12000

13000

15000

15000

Static Pressure

Pa

40

40

40

40

40

Width/Height/Depth

mm

1250/1615/765

1250/1615/765

1250/1615/765

1250/1615/765

1250/1615/765

Net weight

Kg

255

255

255

303

303

Sound pressure

dB (A)

57

57

58

60

60

Power cord (under 20 metres)

mm2

(4+T)x2.5

(4+T)x4

(4+T)x6

(4+T)x10

(4+T)x16

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

Cooling operation range

-5 to 48

-5 to 48

-5 to 48

-5 to 48

-5 to 48

Heating operation range

-20 to 24

-20 to 24

-20 to 24

-20 to 24

-20 to 24

Refrigerant Refrigerant charging Air flow

BRANCH PIPES - 3 PIPES MODEL KCMI 113 (FRG100+FRG200+FRG200) KCMI 213 (FRG100+FRG200+FRG300) KCMI 313 (FRG200+FRG300+FRG300)

BRANCH PIPES - 2 PIPES MODEL KCMI 112 (FRG100+FRG200)

OUTDOOR MODULES T-TYPE BRANCHES

KCMI 413 (FRG200+FRG300+FRG400)

MODEL

KCMI 513 (FRG300+FRG400+FRG500)

KCMER 32 KCMER 33 KCMER 34

242


Inspiration, Innovation, Evolution

DC R-410A

INVERTER

!

DC

INVERTER

GENERAL CHARACTERISTICS Direct-expansion system for 3 air-condensed pipes designed for 25.2 kW to 180 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments.

Modular design with the option of combining the 5 individual modules (8-10-12-14 and 16 HP) up to 64 hp (4 modules maximum).

Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.

They allow for combinations containing up to 64 indoor units.

It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.

ON TI

OMBIN

A

C

YOUR SE

Fitted with a vertical air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.

Cooling system with double liquid subcooling; the first system performs the subcooling process thanks to the delta-shaped heat exchanger and the second system carries out the subcooling process in each series inverter box, thereby reaching up to 22.1 ºC and very high levels of energy efficiency.

Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).

64

INDOOR UNITS

DC

FULL DC INVERTER

dB

A NEW DESIGN WITH NOISE LEVELS REDUCTION THAT WHICH INCREASES AIRFLOW

INVERTER

AMAZON INDUSTRIAL VRF

High capacity Scroll DC Inverter compressors and ecological R410A refrigerant.

CHOO

243


INDUSTRIAL VRF RANGE OUTDOOR UNITS - 3 PIPES

CHANGEOVER BOXES

3 PIPES

TECHNICAL SPECIFICATIONS KVBM2 DN3

MODEL

KVBM4 DN3

KVBM6 DN3

KVBH2 DN3

KVBH4 DN3

Cooling capacity

kW

Up to 28

Up to 45

Up to 45

Up to 28

Up to 56

Cooling power per output

kW

Up to 16

Up to 16

Up to 16

Up to 16

Up to 16

Max. amount of connectable indoor units

8

16

24

1

1

Maximum amount of indoor units per output

4

4

4

-

-

Width/Height/Depth

mm

630/225/600

960/225/600

960/225/600

630/225/600

960/225/600

Net weight

Kg

19.5

31

35

19.5

31

Inlet liquid pipe Liquid

mm (Inch)

Ø12.7 (1/2")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø12.7 (1/2")

Ø15.9 (5/8")

Inlet liquid pipe high-pressure gas

mm (Inch)

Ø19.1 (3/4")

Ø22.2 (7/8")

Ø22.2 (7/8")

Ø19.1 (3/4")

Ø22.2 (7/8")

Inlet liquid pipe high-pressure gas

mm (Inch)

Ø25.4 (1")

Ø31.8 (1 1/4")

Ø31.8 (1 1/4")

Ø25.4 (1")

Ø31.8 (1 1/4")

Inlet liquid pipe Internal liquid per output

mm (Inch)

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Ø9.53 (3/8")

Inlet liquid pipe Internal gas per output

mm (Inch)

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Ø15.9 (5/8")

Shielded communication wires

mm2

3x0.75

3x0.75

3x0.75

3x0.75

3x0.75

Power wiring (under 20 metres)

mm2

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

(2+T)x2.5

V / F / Hz

220-240 / 1 / 50

220-240 / 1 / 50

220-240 / 1 / 50

220-240 / 1 / 50

220-240 / 1 / 50

Power supply voltage

CHANGEOVER BOX MULTI

244


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS Thanks to the series Changeover, the system is capable of providing heat and cold simultaneously, generating heat recovery in the system and therefore overall energy savings. KVBM boxes available in versions of 2.4 and 6 outputs, they support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model. KVBH boxes are designed for high-capacity ducts units (for further information, please see attached table).

CHANGEOVER BOX MULTIGROUP PER OUTPUT MODEL

NUMBER OF OUTPUTS

Max UI Capacity (KW)

PER CHANGEOVER BOX

Max UI Capacity (KW)

Max UI Capacity (KW)

Max UI Capacity (KW)

KVBM2 DN3

2

16

4

28

8

KVBM4 DN3

4

16

4

45

16

6

16

4

45

24

2

-

-

28

1

KVBH4 DN3

4

-

-

56

1

AMAZON INDUSTRIAL VRF

KVBM6 DN3 KVBH2 DN3

COOLING

HEATING

Â

245


INDUSTRIAL VRF RANGE MEASURING

MEASURING

DISTANCES AND HEIGHT DIFFERENCES MINI AMAZON II DIMENSIONS

2 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A

TOTAL LENGTH OF LIQUID PIPE <45 M CAPACITY OF OUTDOOR UNIT

PIPE DIAMETER MM (INCHES) GAS

LIQUID

From 8 kW to 14 kW

Ø15.9 (5/8”)

Ø9.5 (3/8”)

From 16 kW to 18 kW

Ø19.1 (3/4”)

Ø9.5 (3/8”)

TOTAL LENGTH OF LIQUID PIPE ≥45 M PIPE DIAMETER MM (INCHES)

BRANCH

BRANCH

GAS

LIQUID

KCMI 112

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 112

KCMI 112

Ø22.2 (7/8”)

Ø12.7 (1/2”)

KCMI 212

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (X100W)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES)

BRANCH

GAS

LIQUID

Ø19.1 (3/4”)

Ø12.7 (1/2”)

BRANCH

GAS

LIQUID

A<160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

KCMI 112

160≤A<230

Ø19.1 (3/4”)

Ø9.5 (3/8”)

KCMI 112

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 212

230≤A<330

Ø22.2 (7/8”)

Ø9.5 (3/8”)

KCMI 212

Ø22.2 (7/8”)

Ø12.7 (1/2”)

KCMI 212

Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.

KCMI 112

A - Capacity of indoor unit/units

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C INDOOR UNIT TOTAL CAPACITY (X100W)

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*

PIPE DIAMETER MM (INCHES)

PIPE DIAMETER MM (INCHES)

GAS

LIQUID

GAS

LIQUID

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Ø19.1 (3/4”)

Ø12.7 (1/2”)

A - Capacity of indoor unit/units

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d.

N1

Important:

a

Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

246

e f

N6 N5


Inspiration, Innovation, Evolution

AMAZON UNITARIO FRONT AIR DISCHARGE

2 DUCTS

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <45 M CAPACITY OF OUTDOOR UNIT

PIPE DIAMETER MM (INCHES) GAS

LIQUID

From 20 kW to 22.4 kW

Ø19.1 (3/4”)

Ø9.5 (3/8”)

26 kW

Ø22.2 (7/8")

Ø9.5 (3/8”)

40 kW

Ø25.4 (1")

Ø12.7 (1/2”)

45 kW

Ø25.4 (1")

Ø12.7 (1/2”)

TOTAL LENGTH OF LIQUID PIPE ≥45 M PIPE DIAMETER MM (INCHES)

BRANCH

BRANCH

GAS

LIQUID

KCMI 112

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 212

Ø25.4 (1")

Ø12.7 (1/2”)

KCMI 312

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

KCMI 212

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective branches (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (X100W)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES) GAS

LIQUID

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES)

BRANCH

GAS

LIQUID

BRANCH

A<166

Ø15.9 (5/8”)

Ø9.5 (3/8”)

KCMI 112

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 112

166≤A<230

Ø19.1 (3/4”)

Ø9.5 (3/8”)

KCMI 112

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 212

230≤A<330

Ø22.2 (7/8")

Ø9.5 (3/8”)

KCMI 212

Ø25.4 (1")

Ø12.7 (1/2”)

KCMI 312

330≤A<460

Ø25.4 (1”)

Ø12.7 (1/2”)

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

460≤A<660

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5

A - Capacity of indoor unit/units

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) INDOOR UNIT TOTAL CAPACITY (X100W)

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*

PIPE DIAMETER MM (INCHES)

PIPE DIAMETER MM (INCHES)

GAS

LIQUID

GAS

LIQUID

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Ø19.1 (3/4”)

Ø12.7 (1/2”)

200

Ø19.1 (3/4”)

Ø9.5 (3/8”)

Ø22.2 (7/8”)

Ø12.7 (1/2”)

250

Ø22.2 (7/8”)

Ø9.5 (3/8”)

Ø25.4 (1”)

Ø12.7 (1/2”)

280

Ø22.2 (7/8”)

Ø9.5 (3/8”)

Ø25.4 (1”)

Ø12.7 (1/2”)

400

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

450

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

AMAZON INDUSTRIAL VRF

TABLE C

A - Capacity of indoor unit/units

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d N1

Important:

a

Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

e f

N6 N5

247


INDUSTRIAL VRF RANGE MEASURING

AMAZON UNITARIO TOP AIR DISCHARGE DN3 (28-45 kW)

2 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M CAPACITY OF OUTDOOR UNIT

PIPE DIAMETER MM (INCHES)

TOTAL LENGTH OF LIQUID PIPE ≥90 M PIPE DIAMETER MM (INCHES)

BRANCH

GAS

BRANCH

GAS

LIQUID

LIQUID

28 kW

Ø25.4 (1")

Ø12.7 (1/2”)

KCMI 312

Ø25.4 (1")

Ø12.7 (1/2”)

KCMI 312

From 33.5 to 45 kW

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)

PIPE DIAMETER MM (INCHES) GAS

BRANCH

LIQUID

A<166

Ø19.1 (3/4”)

Ø9.5 (3/8”)

KCMI 112

166≤A<230

Ø22.2 (7/8”)

Ø9.5 (3/8”)

KCMI 212 KCMI 212

230≤A<330

Ø22.2 (7/8”)

Ø12.7 (1/2”)

330≤A<460

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

460≤A<660

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

A - Indoor units capacity

Note: Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M

INDOOR UNIT TOTAL CAPACITY (x100W)

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*

PIPE DIAMETER MM (INCHES)

PIPE DIAMETER MM (INCHES)

GAS

LIQUID

GAS

LIQUID

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Ø19.1 (3/4”)

Ø12.7 (1/2”)

200

Ø19.1 (3/4”)

Ø9.5 (3/8”)

Ø22.2 (7/8”)

Ø12.7 (1/2”)

250

Ø22.2 (7/8”)

Ø9.5 (3/8”)

Ø25.4 (1”)

Ø12.7 (1/2”)

280

Ø22.2 (7/8”)

Ø9.5 (3/8”)

Ø25.4 (1”)

Ø12.7 (1/2”)

400

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

450

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

A - Capacity of indoor unit/units

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d

N1

Important:

a

Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

248

e f

N6 N5


Inspiration, Innovation, Evolution

AMAZON UNITARIO TOP AIR DISCHARGE DN3 (56-67 kW)

2 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M CAPACITY OF OUTDOOR UNIT

PIPE DIAMETER MM (INCHES) GAS

TOTAL LENGTH OF LIQUID PIPE ≥90 M PIPE DIAMETER MM (INCHES)

BRANCH

LIQUID

GAS

BRANCH

LIQUID

From 56 to 61.5 kW

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

67 kW

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M PIPE DIAMETER MM (INCHES) GAS

LIQUID

A<166

Ø15.9 (5/8”)

Ø9.5 (3/8”)

166≤A<230

Ø19.1 (3/4”)

Ø9.5 (3/8”)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M PIPE DIAMETER MM (INCHES)

BRANCH

BRANCH

GAS

LIQUID

KCMI 112

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 112

KCMI 112

Ø22.2 (7/8”)

Ø12.7 (1/2”)

KCMI 212

230≤A<330

Ø22.2 (7/8”)

Ø9.5 (3/8”)

KCMI 212

Ø25.4 (1”)

Ø12.7 (1/2”)

KCMI 312

330≤A<460

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

KCMI 412

460≤A<660

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

660≤A<920

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

920≤A<1350

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5

A - Capacity of indoor unit/units

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) INDOOR UNIT TOTAL CAPACITY (X100W)

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M

DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*

PIPE DIAMETER MM (INCHES)

PIPE DIAMETER MM (INCHES)

GAS

LIQUID

GAS

LIQUID

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Ø19.1 (3/4”)

Ø12.7 (1/2”)

200

Ø19.1 (3/4”)

Ø9.5 (3/8”)

Ø22.2 (7/8”)

Ø12.7 (1/2”)

250

Ø22.2 (7/8”)

Ø9.5 (3/8”)

Ø25.4 (1”)

Ø12.7 (1/2”)

280

Ø22.2 (7/8”)

Ø9.5 (3/8”)

Ø25.4 (1”)

Ø12.7 (1/2”)

400

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

450

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

560

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

AMAZON INDUSTRIAL VRF

TABLE C

A - Capacity of indoor unit/units

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B. N1

Important:

a

Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

e f

N6 N5

249


INDUSTRIAL VRF RANGE MEASURING

AMAZON UNITARIO TOP AIR DISCHARGE DN4 S

2 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M

CAPACITY OF OUTDOOR UNIT

TOTAL LENGTH OF LIQUID PIPE ≥90 M

PIPE DIAMETER MM (INCHES) GAS

PIPE DIAMETER MM (INCHES)

BRANCH

LIQUID

GAS

BRANCH

LIQUID

28 kW

Ø22.2 (7/8")

Ø9.5 (3/8”)

KCMI 212

Ø25.4 (1")

Ø12.7 (1/2”)

33,5 to 40 kW

Ø25.4 (1")

Ø12.7 (1/2”)

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312 KCMI 312

45 kW

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

KCMI 412

50 to 67 kW

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

73 to 90kW

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 412

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M

CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)

PIPE DIAMETER MM (INCHES) GAS

LIQUID

A<168

Ø15.9 (5/8”)

Ø9.5 (3/8”)

168≤A<224

Ø19.1 (3/4”)

Ø9.5 (3/8”)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M PIPE DIAMETER MM (INCHES)

BRANCH

BRANCH

GAS

LIQUID

KCMI 112

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 112

KCMI 112

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 212 KCMI 312

224≤A<330

Ø22.2 (7/8")

Ø9.5 (3/8”)

KCMI 212

Ø25.4 (1")

Ø12.7 (1/2”)

330≤A<470

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

KCMI 312

470≤A<710

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

710≤A<1040

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 412

1040≤A<1540

Ø41.3 (1”-5/8)

Ø19.1 (3/4”)

KCMI 412

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 412

A - Indoor units capacity

Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C DISTANCE BETWEEN BRANCH AND INDOOR UNIT ≤10 M PIPE DIAMETER MM (INCHES)

INDOOR UNIT TOTAL CAPACITY (x100W)

DISTANCE BETWEEN BRANCH AND INDOOR UNIT >10 M* PIPE DIAMETER MM (INCHES)

GAS

LIQUID

GAS

LIQUID

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Ø19.1 (3/4”)

Ø12.7 (1/2”)

200

Ø19.1 (3/4”)

Ø9.5 (3/8”)

Ø22.2 (7/8")

Ø12.7 (1/2”)

250

Ø22.2 (7/8")

Ø9.5 (3/8”)

Ø25.4 (1")

Ø12.7 (1/2”)

280

Ø22.2 (7/8")

Ø9.5 (3/8”)

Ø25.4 (1")

Ø12.7 (1/2”)

400

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

450

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

560

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

A - Capacity of indoor unit/units

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B. N1

Important:

a

Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

250

e f

N6 N5


Inspiration, Innovation, Evolution

AMAZON III W

2 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M PIPE DIAMETER MM (INCHES) GAS LIQUID 25.2 kW Ø22.2 (7/8") Ø9.5 (3/8”) 28 kW Ø22.2 (7/8") Ø9.5 (3/8”) 33.5 kW Ø25.4 (1”) Ø12.7 (1/2”) 45 kW Ø28.6 (1”-1/8) Ø12.7 (1/2”) From 50 to 61.5 kW Ø28.6 (1”-1/8) Ø15.9 (5/8”) 67 kW Ø28.6 (1”-1/8) Ø15.9 (5/8”) From 73 to 95 kW Ø34.9 (1”-3/8) Ø19.1 (3/4”) 100 kW Ø41.3 (1”-5/8) Ø19.1 (3/4”) Note: To select the main pipe, use the greater diameter between A and B. CAPACITY OF OUTDOOR UNIT

TOTAL LENGTH OF LIQUID PIPE ≥90 M PIPE DIAMETER MM (INCHES) GAS LIQUID Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1") Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø15.9 (5/8”) Ø34.9 (1”-3/8) Ø15.9 (5/8”) Ø34.9 (1”-3/8) Ø19.1 (3/4”) Ø34.9 (1”-3/8) Ø19.1 (3/4”) Ø41.3 (1”-5/8) Ø22.2 (7/8”) Ø41.3 (1”-5/8) Ø22.2 (7/8”)

BRANCH KCMI 212 KCMI 212 KCMI 312 KCMI 312 KCMI 312 KCMI 312 KCMI 412 KCMI 412

BRANCH KCMI 212 KCMI 312 KCMI 312 KCMI 312 KCMI 412 KCMI 412 KCMI 412 KCMI 412

2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M

PIPE DIAMETER MM (INCHES) BRANCH GAS LIQUID A<166 Ø15.9 (5/8”) Ø9.5 (3/8”) KCMI 112 166≤A<230 Ø19.1 (3/4”) Ø9.5 (3/8”) KCMI 112 230≤A<330 Ø22.2 (7/8") Ø9.5 (3/8”) KCMI 212 330≤A<460 Ø28.6 (1”-1/8) Ø12.7 (1/2”) KCMI 312 460≤A<660 Ø28.6 (1”-1/8) Ø15.9 (5/8”) KCMI 312 660≤A<920 Ø34.9 (1”-3/8) Ø19.1 (3/4”) KCMI 412 920≤A<1350 Ø41.3 (1”-5/8) Ø19.1 (3/4”) KCMI 412 Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L3>=L4 or L5.

PIPE DIAMETER MM (INCHES) GAS LIQUID Ø19.1 (3/4”) Ø12.7 (1/2”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1") Ø12.7 (1/2”) Ø34.9 (1”-3/8) Ø15.9 (5/8”) Ø34.9 (1”-3/8) Ø19.1 (3/4”) Ø41.3 (1”-5/8) Ø22.2 (7/8") Ø41.3 (1”-5/8) Ø22.2 (7/8") L1>=L2 and

BRANCH KCMI 112 KCMI 212 KCMI 312 KCMI 412 KCMI 412 KCMI 412 KCMI 412

A - Indoor units capacity

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C

A≤45 56≤A≤160 200 250 280 400 450 560

DISTANCE BETWEEN BRANCH AND INDOOR UNIT ≤10 M PIPE DIAMETER MM (INCHES) GAS LIQUID Ø12.7 (1/2”) Ø6.4 (1/4”) Ø15.9 (5/8”) Ø9.5 (3/8”) Ø19.1 (3/4”) Ø9.5 (3/8”) Ø22.2 (7/8”) Ø9.5 (3/8”) Ø22.2 (7/8”) Ø9.5 (3/8”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø15.9 (5/8”)

DISTANCE BETWEEN BRANCH AND INDOOR UNIT >10 M* PIPE DIAMETER MM (INCHES) GAS LIQUID Ø15.9 (5/8”) Ø9.5 (3/8”) Ø19.1 (3/4”) Ø12.7 (1/2”) Ø22.2 (7/8”) Ø12.7 (1/2”) Ø25.4 (1”) Ø12.7 (1/2”) Ø25.4 (1”) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø15.9 (5/8”)

AMAZON INDUSTRIAL VRF

INDOOR UNIT TOTAL CAPACITY (x100W)

A - Capacity of indoor unit/units

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B.

4 Selection of drifters (L,M) and pipes (G1,g1,g2,g3) of outdoor unit when there is more than one outdoor module. TABLE D NUMBER OF ONLINE OUTDOOR UNITS

BRANCH MODEL

PIPES

2 (L) 3 (L and M)

KCME 12 KCME 13

G1

PIPE DIAMETER MM (INCHES) GAS LIQUID

OUTDOOR UNIT MODULES CAPACITY

g1,g2 and g3

Not required All possibilities Ø41.3 (1”-5/8) From 25.2 to 28 kW Ø25.4 (1”) 33.5 kW Ø28.6 (1”-1/8)

Ø19.1 (3/4”) Ø12.7 (1/2”) Ø15.9 (5/8”)

N1 a

Important: Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

e f

N6 N5

251


INDUSTRIAL VRF RANGE MEASURING

AMAZON IV PRO

2 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M

CAPACITY OF OUTDOOR UNIT

PIPE DIAMETER MM (INCHES) GAS

LIQUID

25.2 kW

Ø22.2 (7/8")

Ø9.5 (3/8”)

28 kW

Ø22.2 (7/8")

Ø9.5 (3/8”)

From 33.5 to 40 kW

Ø25.4 (1")

TOTAL LENGTH OF LIQUID PIPE ≥90 M BRANCH

PIPE DIAMETER MM (INCHES)

BRANCH

GAS

LIQUID

KCMI 212

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 212

Ø25.4 (1")

Ø12.7 (1/2”)

KCMI 312

Ø12.7 (1/2”)

KCMI 312

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

KCMI 212

45 kW

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

KCMI 312

From 50 to 61.5 kW

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

67 kW

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

From 73 to 95 kW

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 412 KCMI 412

From 100 to 140 kW

Ø41.3 (1”-5/8)

Ø19.1 (3/4”)

KCMI 412

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

From 145 to 185 kW

Ø41.3 (1”-5/8)

Ø22.2 (7/8”)

KCMI 412

Ø53.9 (2”-1/8)

Ø25.4 (1”)

KCMI 512

From 190 kW to 246 kW

Ø53.9 (2”-1/8)

Ø25.4 (1”)

KCMI 512

Ø53.9 (2”-1/8)

Ø25.4 (1”)

KCMI 512

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and intermediate pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C): TABLE B CAPACITY OF UNITS CONECTED TO BRANCH OR OUTDOOR UNIT (x100W)

LENGTH BETWEEN THE FIRST BRANCH AND THE FARTHEST INDOOR UNIT ≤40 M. PIPE DIAMETER MM (INCHES) GAS

LIQUID

A<166

Ø15.9 (5/8”)

Ø9.5 (3/8”)

166≤A<230

Ø19.1 (3/4”)

Ø9.5 (3/8”)

BRANCH

LENGTH BETWEEN THE FIRST BRANCH AND THE FARTHEST INDOOR UNIT >40 M. PIPE DIAMETER MM (INCHES)

BRANCH

GAS

LIQUID

KCMI 112

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 112

KCMI 112

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 212 KCMI 312

230≤A<330

Ø22.2 (7/8")

Ø9.5 (3/8”)

KCMI 212

Ø25.4 (1")

Ø12.7 (1/2”)

330≤A<460

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

KCMI 312

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

KCMI 312

460≤A<660

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 312

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

KCMI 412

660≤A<920

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 412

920≤A<1350

Ø41.3 (1”-5/8)

Ø19.1 (3/4”)

KCMI 412

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 412

1350≤A<1800

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 412

Ø53.9 (2”-1/8)

Ø22.2 (7/8")

KCMI 512

1800≤A

Ø53.9 (2”-1/8)

Ø25.4 (1")

KCMI 512

Ø53.9 (2”-1/8)

Ø25.4 (1")

KCMI 512

A - Indoor units capacity

Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.

3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C DISTANCE BETWEEN BRANCH AND INDOOR UNIT ≤10 M

INDOOR UNIT TOTAL CAPACITY (x100W)

DISTANCE BETWEEN BRANCH AND INDOOR UNIT >10 M*

PIPE DIAMETER MM (INCHES)

PIPE DIAMETER MM (INCHES)

GAS

LIQUID

GAS

LIQUID

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

Ø19.1 (3/4”)

Ø12.7 (1/2”)

200

Ø19.1 (3/4”)

Ø9.5 (3/8”)

Ø22.2 (7/8")

Ø12.7 (1/2”)

250

Ø22.2 (7/8")

Ø9.5 (3/8”)

Ø25.4 (1")

Ø12.7 (1/2”)

280

Ø22.2 (7/8")

Ø9.5 (3/8”)

Ø25.4 (1")

Ø12.7 (1/2”)

400

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

450

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

560

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B.

252

A - Capacity of indoor unit/units


Inspiration, Innovation, Evolution

4 Selection of drifters (L,M,N) and pipes (G1,G2,g1,g2,g3,g4) of outdoor unit when there is more than one outdoor module. TABLE D NUMBER OF ONLINE OUTDOOR UNITS

BRANCH MODEL

2 (L)

KCME 12

PIPE DIAMETER MM (INCHES)

OUTDOOR UNIT MODULES CAPACITY

PIPES

GAS

LIQUID

Not required

3 (L and M)

KCME 13

G1

All possibilities

Ø41.3 (1”-5/8)

Ø19.1 (3/4”)

4 (L, M and N)

KCME 14

G2

All possibilities

Ø41.3 (1”-5/8)

Ø22.2 (7/8”)

From 25.2 to 33.5 kW

Ø25.4 (1")

Ø12.7 (1/2”)

From 40 to 61.5 kW

Ø34.9 (1”-3/8)

Ø15.9 (5/8”)

g1,g2,g3 and g4

L

M

N

N1 a N2

B

L1

A

L2 L3

C

b L4

N3

c

D

d

L5

N4 E

Important:

e f

N6 N5

Each elbow and drifter equals to a pipe of 0.5 metres. AMAZON INDUSTRIAL VRF

The minimum distance between branch pipes is 0.5m.

253


INDUSTRIAL VRF RANGE MEASURING

AMAZON III PRO

3 PIPES

HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE

1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M CAPACITY OF OUTDOOR UNIT

TOTAL LENGTH OF LIQUID PIPE ≥90 M

PIPE DIAMETER MM (INCHES)

25.2 kW

HIGH-PRESSURE GAS Ø22.2 (7/8")

HIGH-PRESSURE GAS Ø19.1 (3/4”)

Ø9.5 (3/8”)

28 kW

Ø22.2 (7/8")

Ø19.1 (3/4”)

Ø12.7 (1/2”)

BRANCH

LIQUID

PIPE DIAMETER MM (INCHES)

BRANCH

KCMI 213

HIGH-PRESSURE GAS Ø22.2 (7/8")

HIGH-PRESSURE GAS Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 213

KCMI 213

Ø22.2 (7/8")

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 213

LIQUID

33.5 kW

Ø25.4 (1")

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 313

Ø25.4 (1")

Ø19.1 (3/4”)

Ø15.9 (5/8”)

KCMI 313

From 40 to 45 kW

Ø28.6 (1”-1/8)

Ø22.2 (7/8")

Ø15.9 (5/8”)

KCMI 313

Ø28.6 (1”-1/8)

Ø22.2 (7/8")

Ø15.9 (5/8”)

KCMI 313

From 50 to 61.5 kW

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 413

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø19.1 (3/4”)

KCMI 413

67 kW

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

KCMI 413

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø19.1 (3/4”)

KCMI 413

From 73 to 95 kW

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø19.1 (3/4”)

KCMI 413

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø22.2 (7/8")

KCMI 413

From 100 to 140 kW

Ø41.3 (1”-5/8)

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 513

Ø41.3 (1”-5/8)

Ø34.9 (1”-3/8)

Ø22.2 (7/8")

KCMI 513

From 145 to 185 kW

Ø53.9 (2”-1/8)

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 513

Ø53.9 (2”-1/8)

Ø41.3 (1”-5/8)

Ø25.4 (1")

KCMI 513

Note: To select the main pipe, use the greater diameter between A and B.

2 Selection of main and intermediate pipes (L1,L2,L3,L4,L5,L6,L7,L8,L9,L10,L11) and their respective drifters (A,B,C,D,E): TABLE B CAPACITY OF UNITS CONECTED TO BRANCH OR OUTDOOR UNIT (x100W)

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M

DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M

PIPE DIAMETER MM (INCHES)

PIPE DIAMETER MM (INCHES) BRANCH

A<56

HIGHPRESSURE GAS Ø12.7 (1/2”)

HIGHPRESSURE GAS Ø9.5 (3/8”)

Ø6.4 (1/4”)

56≤A<166

Ø19.1 (3/4”)

Ø15.9 (5/8”)

Ø9.5 (3/8”)

BRANCH

KCMI 113

HIGHPRESSURE GAS Ø15.9 (5/8”)

HIGHPRESSURE GAS Ø12.7 (1/2”)

Ø9.5 (3/8”)

KCMI 113

KCMI 113

Ø22.2 (7/8")

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 213

LIQUID

LIQUID

166≤A<230

Ø22.2 (7/8")

Ø19.1 (3/4”)

Ø9.5 (3/8”)

KCMI 213

Ø25.4 (1")

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 313

230≤A<330

Ø22.2 (7/8")

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 213

Ø25.4 (1")

Ø22.2 (7/8")

Ø15.9 (5/8”)

KCMI 313

330≤A<460

Ø28.6 (1”-1/8)

Ø22.2 (7/8")

Ø12.7 (1/2”)

KCMI 313

Ø34.9 (1”-3/8)

Ø25.4 (1")

Ø15.9 (5/8”)

KCMI 313

460≤A<660

Ø28.6 (1”-1/8)

Ø22.2 (7/8")

Ø15.9 (5/8”)

KCMI 313

Ø34.9 (1”-3/8)

Ø25.4 (1")

Ø19.1 (3/4”)

KCMI 413

660≤A<920

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø19.1 (3/4”)

KCMI 413

Ø41.3 (1”-5/8)

Ø34.9 (1”-3/8)

Ø22.2 (7/8")

KCMI 513

920≤A<1350

Ø41.3 (1”-5/8)

Ø34.9 (1”-3/8)

Ø19.1 (3/4”)

KCMI 513

Ø53.9 (2”-1/8)

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 513

1350≤A

Ø53.9 (2”-1/8)

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 513

Ø53.9 (2”-1/8)

Ø41.3 (1”-5/8)

Ø22.2 (7/8")

KCMI 513

Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2>=L3>=L4 or L1>=L7>=L9.

A - Indoor units capacity

3 Selection of pipes in indoor units (a,b,c,d,e,f,g,h,i,j,k,l,m,n) and their respective drifters (F,G,H,I) TABLE C CAPACITY OF INDOOR UNIT (x100W)

LENGTH BETWEEN KVB BOX/BRANCH AND INDOOR UNIT ≤10 M PIPE DIAMETER MM (INCHES) GAS

LIQUID

LENGTH BETWEEN KVB BOX/BRANCH AND INDOOR UNIT >10 M* BRANCH

PIPE DIAMETER MM (INCHES) GAS

LIQUID

BRANCH

A≤45

Ø12.7 (1/2”)

Ø6.4 (1/4”)

KCMI 112

Ø15.9 (5/8”)

Ø9.5 (3/8”)

KCMI 112

56≤A≤160

Ø15.9 (5/8”)

Ø9.5 (3/8”)

KCMI 112

Ø19.1 (3/4”)

Ø12.7 (1/2”)

KCMI 112

200

Ø19.1 (3/4”)

Ø9.5 (3/8”)

Ø22.2 (7/8")

Ø12.7 (1/2”) Ø12.7 (1/2”)

250

Ø22.2 (7/8")

Ø9.5 (3/8”)

Ø25.4 (1")

280

Ø22.2 (7/8")

Ø9.5 (3/8”)

Ø25.4 (1")

Ø12.7 (1/2”)

400

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

450

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

Ø28.6 (1”-1/8)

Ø12.7 (1/2”)

560

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

Ø28.6 (1”-1/8)

Ø15.9 (5/8”)

Not applicable

Not applicable

A - Indoor units capacity

254


Inspiration, Innovation, Evolution

4 Selection of drifters (L,M,N) and pipes (G1,G2,g1,g2,g3,g4) of outdoor unit when there is more than one outdoor module. TABLE D NUMBER OF ONLINE OUTDOOR UNITS

BRANCH MODEL

2 (L)

KCMER 32

PIPES

OUTDOOR UNIT MODULES CAPACITY

PIPE DIAMETER MM (INCHES) HIGH-PRESSURE GAS

HIGH-PRESSURE GAS

LIQUID

Not required

3 (L and M)

KCMER 33

G1

All possibilities

Ø34.9 (1”-3/8)

Ø28.6 (1”-1/8)

Ø19.1 (3/4”)

4 (L, M and N)

KCMER 34

G1 and G2

All possibilities

Ø41.3 (1”-5/8)

Ø34.9 (1”-3/8)

Ø22.2 (7/8")

From 25.2 to 33.5 kW

Ø22.2 (7/8")

Ø19.1 (3/4”)

Ø12.7 (1/2”)

From 40 to 45 kW

Ø28.6 (1”-1/8)

Ø22.2 (7/8")

Ø15.9 (5/8”)

g1,g2,g3 and g4

L

M

N

5 Selection of KVB boxes (1,2,3,4,5,6) TABLE E CAPACITY PER OUTPUT MODEL

CAPACITY (KW)

QUANTITY (NO)

CAPACITY (KW)

QUANTITY (NO)

Max. IU

Max. IU

Max. IU

Max. IU

KVBM2 DN3

16

KVBM4 DN3

16

KVBM6 DN3

16

KVBH2 DN3

4

Not applicable

28

8

45

16

45

24

28 56

1

AMAZON INDUSTRIAL VRF

KVBH4 DN3

CAPACITY PER KVB

Important: Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.

255


INDUSTRIAL VRF RANGE MEASURING

DISTANCES AND HEIGHTS

2 PIPES

MINI AMAZON II

8/10,5 KW

Total length from outdoor unit to all the indoor units.

PIPING LENGTH

Length between the outdoor unit and the furthest indoor unit.

≤45m

≤60m

Equivalent

≤50m

≤70m

Length between one indoor unit and the closest distributor

HEIGHT DIFFERENCE

≤100m

Real

Length between the first distributor and the furthest indoor unit.

Level difference between outdoor unit and indoor unit

12/14/16/18KW

≤20 (40m*) 15m

The outdoor unit is higher than the indoor unit

≤30m

The outdoor unit is lower than the indoor unit

≤20m

Level difference between indoor units

≤8m

*Check for lengths between 20 and 40 metres.

AMAZON IV PRO

ALL MODULES

Total length from outdoor unit to all the indoor units.

PIPING LENGTH

Length between the outdoor unit and the furthest indoor unit.

Real

≤ 175m

Equivalent

≤ 200m

Length between the first distributor and the furthest indoor unit. Length between one indoor unit and the closest distributor

HEIGHT DIFFERENCE

Level difference between outdoor unit and indoor unit

≤ 1000m

≤ 40 (90m*) -

The outdoor unit is higher than the indoor unit

≤ 110m

The outdoor unit is lower than the indoor unit

≤90m

Level difference between indoor units

≤ 30m

*Check for lengths between 40 and 90 metres.

AMAZON III W

8/10/12 HP

Total length from outdoor unit to all the indoor units.

PIPING LENGTH

Length between the outdoor unit and the furthest indoor unit.

Real

≤120m

Equivalent

≤150m

Length between the first distributor and the furthest indoor unit. Length between one indoor unit and the closest distributor

HEIGHT DIFFERENCE

Level difference between outdoor unit and indoor unit

Level difference between indoor units

*Check for lengths between 40 and 90 metres.

256

≤300m

≤40 (90 m*) -

The outdoor unit is higher than the indoor unit

≤50m

The outdoor unit is lower than the indoor unit

≤40m ≤30m


Inspiration, Innovation, Evolution

MINI AMAZON II OUTDOOR UNIT INDOOR UNITS

30m 8m

50m (70m)

20m (40m)

AMAZON IV PRO

OUTDOOR UNIT INDOOR UNITS

110m 30 m

AMAZON INDUSTRIAL VRF

200 m

40m (90m)

AMAZON III W

OUTDOOR UNIT INDOOR UNITS

50m

150 m

30 m

40m (90m)

257


INDUSTRIAL VRF RANGE MEASURING

DISTANCES AND HEIGHTS

2 PIPES

AMAZON UNITARIO FRONT AIR DISCHARGE

20/22/24 KW

40/45 KW

≤120m

≤250m

Real

≤60m

≤100m

Equivalent

≤70m

≤120m

Length between the first distributor and the furthest indoor unit.

≤20m

≤40 m

Length between one indoor unit and the closest distributor

≤15m

≤15m

The outdoor unit is higher than the indoor unit

≤30m

≤30m

The outdoor unit is lower than the indoor unit

≤20m

≤20m

≤8m

≤8m

10-16 HP

20/22/24 HP

≤350m

≤1000m

Real

≤150m

≤175m

Equivalent

≤175m

≤200m

Length between the first distributor and the furthest indoor unit.

≤40

≤40 (90m*)

Length between one indoor unit and the closest distributor

≤15

≤15

The outdoor unit is higher than the indoor unit

≤70m

≤110m

The outdoor unit is lower than the indoor unit

≤50m

≤70m

≤15m

≤30m

Total length from outdoor unit to all the indoor units.

PIPING LENGTH

HEIGHT DIFFERENCE

Length between the outdoor unit and the furthest indoor unit.

Level difference between outdoor unit and indoor unit

Level difference between indoor units

AMAZON UNITARIO TOP AIR DISCHARGE DN3 Total length from outdoor unit to all the indoor units.

PIPING LENGTH

HEIGHT DIFFERENCE

Length between the outdoor unit and the furthest indoor unit.

Level difference between outdoor unit and indoor unit

Level difference between indoor units

*Check for lengths between 40 and 90 metres.

AMAZON UNITARIO TOP AIR DISCHARGE DN4 S Total length from outdoor unit to all the indoor units.

PIPING LENGTH

Length between the outdoor unit and the furthest indoor unit.

≤ 175m

Equivalent

≤ 200m

Length between one indoor unit and the closest distributor

HEIGHT DIFFERENCE

Level difference between indoor units

*Check for lengths between 40 and 90 metres.

258

≤ 1000m

Real

Length between the first distributor and the furthest indoor unit.

Level difference between outdoor unit and indoor unit

ALL MODULES

≤ 40 (90m*) -

The outdoor unit is higher than the indoor unit

≤ 110m

The outdoor unit is lower than the indoor unit

≤90m ≤ 30m


Inspiration, Innovation, Evolution

AMAZON UNITARIO FRONT AIR DISCHARGE

OUTDOOR UNIT INDOOR UNITS

30m 8m

70m (120m)

20m (40m)

AMAZON UNITARIO TOP AIR DISCHARGE DN3

OUTDOOR UNIT INDOOR UNITS

50m 30 m

AMAZON INDUSTRIAL VRF

150 m

40m (90m)

AMAZON UNITARIO TOP AIR DISCHARGE DN4 S OUTDOOR UNIT INDOOR UNITS

110m

200 m

30 m

40m (90m)

259


INDUSTRIAL VRF RANGE MEASURING

DISTANCES AND HEIGHTS

3 PIPES

AMAZON III PRO 3-DUCTS

AMAZON III PRO

ALL MODULES

Total length from outdoor unit to all the indoor units.

PIPING LENGTH

Length between the outdoor unit and the furthest indoor unit.

≤175 m

Equivalent

≤200 m

Length between the first distributor and the furthest indoor unit.

HEIGHT DIFFERENCE

Level difference between outdoor unit and indoor unit

≤1000 m

Real

≤40m (90 m)

The outdoor unit is higher than the indoor unit

≤110m

The outdoor unit is lower than the indoor unit

≤ 70 m

Level difference between indoor units

≤ 30 m

*Length between the KVB box and the furthest indoor unit. 40 m. *Check for lengths between 40 and 90 metres.

AMAZON III PRO

OUTDOOR UNIT INDOOR UNITS

110m

200 m

40m (90m)

260

30 m


SELECTA

Inspiration, Innovation, Evolution

COOLING SIZING SYSTEM Selecta software download

1 Please, enter project’s data and information. 2 Calculate the load of the project. 3 Select outdoor and indoor units. 4 Project’s pipes diagram. 5 Select controller.

AMAZON INDUSTRIAL VRF

Congratulations! Your project is ready.

261


INDUSTRIAL VRF RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

CEPSA LABORATORIES BUSINESS CENTRE Location: Huelva Units installed: Amazon 2 pipes Capacity: 30 kW

262


AMAZON INDUSTRIAL VRF

Inspiration, Innovation, Evolution

263


INDUSTRIAL VRF RANGE KEY INSTALLATIONS

BUENAVISTA CONFERENCE CENTRE METROPOL PARASOL “LAS SETAS” BUSINESS CENTRE PUBLIC BUILDING Location: Oviedo Location: Seville New construction Initial situation: Units installed: 2 pipes Units installed:Amazon Zen Inverter Capacity: 200 kW Capacity: 140 kW

THE AMAZON RANGE OFFERS THE MOST VERSATILE RANGE OF CAPACITIES AND COMBINABLE INDOOR AND OUTDOOR UNITS. AMAZON UNITS HAVE THE HIGHEST TECHNOLOGY FOR LARGE FACILITIES, ALWAYS RESPECTING THE ENVIRONMENT.

OTHER CUSTOMERS THAT HAVE TRUSTED IN KAYSUN HOTELS Ciudad de Alcañiz Hotel (Teruel), Eritaña Civil Guard Headquarters (Seville), Dolce Fregate Hotel (Provence), Ibis Hotel (Seville). PUBLIC BUILDINGS Óvalo Centro Social Services building (Zaragoza), Deputy Major's Office (Málaga), Reus Town Council (Tarragona), ADIF Railway Infrastructures Manager Offices (Asturias), Department of Agriculture (Badajoz).

264

SCHOOLS AND UNIVERSITITES San Luis School (Minorca), Camino de Gelves Nursery School (Seville). HOSPITALS, HEALTH CLINICS AND CENTRES Adharaz School (Seville), Altasierra School (Seville), San Francisco de Paula School (Seville), Calasancio School (Córdoba), Pablo de Olavide University (Seville), Guijuelo Nursery School (Salamanca), University School of Technical

Industrial Engineering (Barcelona), Santa Maria del Pilar School (Madrid), Sagrado Corazón Health Clinic (Seville). RESIDENCES Palacio de la calle Mayor Residence (Madrid). LEISURE CENTRES Sant Josep Sports Centre (Barcelona), Amezketa Library (Guipúzcoa), Requejada Sports Centre (Cantabria), School of Music (Jerez de la Frontera), Conferences and Exhibition Centre (Madrid)

Pinto Library (Madrid). BUSINESS CENTRES AND OFFICES Mercedes Authorised Dealer (Barcelona), Caritas charitable organisation (Barcelona), ThyssenKrupp Elevators (Barcelona), Aceites Abril S.L. (Ourense), Zara Home (Vitoria), Aki (Granollers).


Inspiration, Innovation, Evolution

LEFTIES

CAMBRILS PARK RESORT

CASTILLO DE ARTEAGA

COMMERCIAL BUILDING

CAMPING RESORT

HOTEL

Location: France and Belgium Units installed: Amazon 2 pipes Capacity: 50 kW

Location: Cambrils (Tarragona) Units installed: Amazon 3 pipes Capacity: 2000 kW

Location: Arteaga (Vizcaya) Units installed: Amazon 3 pipes Capacity: 1000 kW

DOLCE FREGATE

VIDIGUEIRA

INSTITUTO POLITÉCNICO DO PORTO

HOTEL

WINE CELLAR

POLYTECHNIC COLLEGE

Location: Provence (France) Units installed: Amazon 2 pipes Capacity: 160 kW

Location: Vidigueira (Portugal) Units installed: K2F-615DN4S Capacity: 61.5kW

Location: Porto (Portugal) Units installed: 2x K2F-450DN3 Capacity: 90kW

MERCURE HOTELS

ALL SUITES

HOTEL

APART HOTEL

AMAZON INDUSTRIAL VRF

HYUNDAI – CENTRAL MOTOR DEALERSHIP

Location: Lyon (France)

Location: Ibiza Initial situation: Renovation Units installed: Minichillers Capacity: 251 kW

Location: Pessac (France) Units installed: 3 pipes

COURS BASTIDE

AMD DECOLLETAGE

DUBLIN

SCHOOL

AUTOMOTIVE COMPONENTS FACTORY

HOTEL

Location: Marseille (France)

Location: Marnaz (France) Units installed: K2F-615DN4S Capacity: 61.5kW

Location: Dublin (Ireland) Units installed: Amazon Unitario

265


CONTROLS CONTROL SYSTEM RANGE

INTRODUCTION TO THE PRODUCT RANGE................................. 268 OUR RANGE OF PRODUCTS..................................................... 269 WIRELESS SINGLE AND WIRED CONTROLLERS.................... 270 CENTRALISED............................................................................ 272 INTEGRATED CONTROLLERS................................................... 274 ACCESSORIES............................................................................. 282 KEY INSTALLATIONS..................................................................... 284


CONTROL SYSTEM RANGE

CONTROL SYSTEMS

CONTROLS

CONTROLS


CONTROL SYSTEMS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

CONTROLS CONTROL SYSTEMS RANGE

Introducing the two new KAYSUN controllers range based on centralised control and fitted with touchscreen. KCCT-64 IPS and KCCT-384 IPS models are able to control 64 indoor units and 384 indoor units, respectively. Both controllers are fitted with a user-friendly intuitive touchscreen. The weekly timer and units groups control are some of their main functions available. Besides, KCCT-384 IPS controller allows the connection to its Web function through a LAN cable and includes plans of the units’ location. Furthermore, KAYSUN offers a complete range of interfaces for BMS Lonworks, Bacnet, Modbus and KNX, v Kaynet control, a programme for managing KAYSUN cooling systems by computer.

KCCT-64 IPS

NEW

"COMPREHENSIVE SOLUTIONS AT YOUR FINGERTIPS" Finally, we would like to introduce the KCC-64 WEB controller, a new device that allows for the remote control of 64 indoor units through the Internet by Smartphone, Tablet or PC.

KCCT-384 IPS

Our new product for 2018 is this controller fitted with touchscreen. This is a user-friendly intuitive device fitted with the most advanced functions, such as units groups control, alarm buzzer, scheduler, parameters blocking, as well as operation mode and operating Temperature.

NEW

This new centralised controllers offers the same functions as KCCT 64 IPS model; however, it is able to control up to 384 indoor units in 6 ports, and 64 indoor units per port. It also provides users with exclusive functions, such a Web function to allow remote connection, as well as the possibility of displaying the plans of the building/house.

NEW

KC-03.1 SPS Based on the KC-03 SPS model, the standard controller of the range, we introduce the KC-03.1 SPS model. This device has been designed for Kaysun ducts units. It is able to adjust static pressure both automatically and manually, which makes it the perfect controller for these units. Besides, it is bidirectional, is fitted with a weekly timer and provides failures codes.

268

NEW


Inspiration, Innovation, Evolution

OUR RANGES INDIVIDUAL WIRELESS

(Page 270)

COMPATIBILITY

SUITE PRODIGY 1x1

AUREA II 1x1

ONNIX 1x1

PRODIGY 1x1

AUREA II 1x1

ONNIX 1x1

KSD 1x1

MULTI

KSD 1x1

MULTI

ZEN

AMAZON

ZEN

AMAZON

KID-02 S KI-02.3 S SINGLE WIRED

(Page 270)

COMPATIBILITY

SUITE

Except for Aurea II model

Except for SuperSlim Cassette and Floor Standing models

KC-03 SPS

Ducts and cassette

Except for SuperSlim Cassette and Floor Standing models

KC-03.1 SPS

Ducts and cassette

Except for SuperSlim Cassette and Floor Standing models

KCT-02.1 SR

Except for Aurea II model

Except for SuperSlim Cassette and Floor Standing models

KC-02.1 H

Except for Aurea II model

Except for SuperSlim Cassette and Floor Standing models

KC-01 S

NEW

CENTRALISED

SUITE

(Page 272)

COMPATIBILITY

PRODIGY 1x1

AUREA II 1x1

ONNIX 1x1

KSD 1x1

ZEN

AMAZON

ZEN

AMAZON

ZEN

AMAZON

MULTI

KMC-32 E KCCT-64 I (B)

Except for wall-mounted and KSD units.

NEW

KCCT-64 IPS

Except for wall-mounted and KSD units.

NEW

KCCT-384 IPS

Except for wall-mounted and KSD units.

KCC-64 WEB

Except for wall-mounted and KSD units.

PRODIGY 1x1

AUREA II 1x1

ONNIX 1x1

KSD 1x1

MULTI

K01-LON

Except for wall-mounted and KSD units.

K01-BACNET

Except for wall-mounted and KSD units.

K02-MODBUS

Except for wall-mounted and KSD units.

K01 MODBUS

Except for wall-mounted and KSD units.

KAYNET CONTROL

Except for wall-mounted and KSD units.

K01-KNX

Except for wall-mounted and KSD units.

CONTROL SYSTEMS

NEW

SUITE

(Page 274)

COMPATIBILITY

CONTROLS

BMS AND SOFTWARE

K01-WIFI ACCESSORIES

SUITE

(Page 282)

COMPATIBILITY

PRODIGY 1x1

K01-WATT

AUREA II 1x1

ONNIX 1x1

KSD 1x1

MULTI Except for MINI AMAZON II

KAHU 269


CONTROL SYSTEMS RANGE SINGLE WIRELESS AND WIRED CONTROLLERS

SINGLE WIRELESS AND WIRED KID-02 S

24ºC 24ºC

-

TURBO

+

GENERAL CHARACTERISTICS • • • • • • • • • • •

Wireless controller FOLLOW ME LED function Turbo function Silence function Night mode 8 ºC function Self-cleaning function Units operating parameters query Units operating parameters change Mute function

MODEL

COMPATIBLE WITH

KID-02 S

SUITE - ZEN

Check available functions for each unit. Standard in Prodigy, Onnix and Aurea ranges.

KI-02.3 S

26ºC

GENERAL CHARACTERISTICS • • • • •

Wireless controller Follow me function 26ºC function. AMAZON indoor units addressing AUTO mode activation/deactivation MODEL

COMPATIBLE WITH

KI-02.3 S

AMAZON

KC-01 S

26ºC

GENERAL CHARACTERISTICS • Wired controller • FOLLOW ME

MODEL

COMPATIBLE WITH

KC-01 S

SUITE* ZEN** AMAZON

* Except for Aurea II model ** Except for Superslim cassette and floor standing models

270


Inspiration, Innovation, Evolution

KC-03 SPS

x2

TWINS

GENERAL CHARACTERISTICS • Wired controller with 2 non-polarised wires • FOLLOW ME • Malfunction codes display • Weekly timer • Capacity to control up to 16 indoor units • Bidirectional

KC-03.1 SPS

MODEL KC-03 SPS

COMPATIBLE WITH SUITE* ZEN**

* Only Ducts ** Except for Superslim cassette and floor standing models

NEW

x2

TWINS

GENERAL CHARACTERISTICS • Wired controller with 2 non-polarised wires • FOLLOW ME • Malfunction codes display • Weekly timer • Automatic adjustment of static pressure in ducts units • Bidirectional

KC-02.1 H

MODEL KC-03 SPS

COMPATIBLE WITH SUITE* ZEN**

* Only Ducts ** Except for Superslim cassette and floor standing models

SPECIAL FOR HOTELS

GENERAL CHARACTERISTICS • Wired controller • Hotel-type simplified controller with Operation mode function hidden • 26ºC function • Memory function

MODEL

COMPATIBLE WITH

KC-02.1 H

SUITE* ZEN** AMAZON

CONTROLS

KCT-02.1 SR

CONTROL SYSTEMS

* Except for Aurea II model ** Except for Superslim cassette and floor standing models

26ºC

GENERAL CHARACTERISTICS • • • • • • •

Wired controller Follow me function Touch sensitive AMAZON indoor units addressing Filter cleaning alarm Built-in infrared signal receiver Memory function

MODEL KCT-02.1 SR

COMPATIBLE WITH SUITE* ZEN** AMAZON

* Except for Aurea II model ** Except for Superslim cassette and floor standing models

271


CONTROL SYSTEMS RANGE CENTRALISED

CENTRALISED KMC-32 E GENERAL CHARACTERISTICS • Centralised display for outdoors • Up to 32 modules • If outdoor unit is fitted with the K01-WATT wattmeter, total consumption of each module is displayed MODEL

COMPATIBLE WITH

KMC-32 E

KCCT-64 IPS

AMAZON

NEW

GENERAL CHARACTERISTICS • • • • • • • •

Indoor centralised controller 6.2” touchscreen User-friendly, intuitive Up to 64 indoor units Units Groups control Schedule timer Malfunction codes display Available in Spanish, English and French MODEL

COMPATIBLE WITH SUITE* ZEN AMAZON

KCCT-64 IPS *Except for wall-mounted and KSD units.

KCCT-64 I (B) GENERAL CHARACTERISTICS • • • •

Touch sensitive Indoor centralised controller Up to 64 indoor units Emergency stop MODEL

COMPATIBLE WITH

KCCT-64 I (B)

SUITE* ZEN AMAZON

*Except for wall-mounted and KSD units.

272


Inspiration, Innovation, Evolution

KCCT-384 IPS

NEW

GENERAL CHARACTERISTICS • Indoor centralised controller • 10.1” touchscreen • User-friendly, intuitive • Up to 384 indoor units • Units Groups control • Schedule timer

• Malfunction codes display • Available in Spanish, English and French • Web function • Building layout

MODEL

COMPATIBLE WITH

KCCT-384 IPS

SUITE* ZEN AMAZON

*Except for wall-mounted and KSD units.

KCC-64 WEB GENERAL CHARACTERISTICS Units control through WEB or Smartphone APP Indoor centralised controller Up to 64 indoor units Weekly timer Non-compatible with superior controls

NEW APP

NEW WEBSITE

MODEL KCC-64 WEB

COMPATIBLE WITH SUITE* ZEN AMAZON

CONTROL SYSTEMS

*Except for wall-mounted and KSD units.

CONTROLS

• • • • •

273


CONTROL SYSTEMS RANGE BMS AND SOFTWARE

BMS AND SOFTWARE K01-LON GENERAL CHARACTERISTICS • BMS interface, direct gateway to Lonworks • Centralised controllers not required • Up to 64 indoor units

MODEL

COMPATIBLE WITH SUITE* ZEN AMAZON

K01-LON *Except for wall-mounted and KSD units.

INSTALLATION EXAMPLE

K01-LON

SYSTEM 1 UP TO 64 INDOOR UNITS

X, Y, E

P, Q, E SYSTEM 2 P, Q, E

BMS

274 274

LONWORKS

SYSTEM N P, Q, E


Inspiration, Innovation, Evolution

K02-MODBUS GENERAL CHARACTERISTICS • BMS interface, direct gateway to MODBUS through RTU and TCP/IP. • Up to 64 indoor units and 4 outdoor units of the same cooling system. • Centralised controllers not required.

MODEL

COMPATIBLE WITH

KO2-MODBUS

SUITE* ZEN AMAZON

*Except for wall-mounted and KSD units.

INSTALLATION EXAMPLE

UP TO 64 INDOOR UNITS

P, Q, E X, Y, E

K02-MODBUS BMS

MODBUS

K1, K2, E

OUTDOOR UNITS

K1, K2, E UP TO 4 OUTDOOR UNITS OF THE SAME COOLING SYSTEM

K01-MODBUS

NEW

GENERAL CHARACTERISTICS

COMPATIBLE WITH

K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

SUITE* ZEN AMAZON

CONTROLS

MODEL

CONTROL SYSTEMS

• BMS interface, direct gateway to MODBUS through RTU (RS-485). • Power supply included. • Three interface types for 1, 4, 8 or 32 indoor units.

*Except for wall-mounted and KSD units.

INSTALLATION EXAMPLE RTU (RS-485)

BMS

XYE

MODBUS

275


CONTROL SYSTEMS RANGE BMS AND SOFTWARE

BMS AND SOFTWARE K01-BACNET GENERAL CHARACTERISTICS • • • •

Direct BMS interface to BACNET. 4 ports available for indoor and outdoor units. Up to 256 indoor units. Up to 128 outdoor units.

MODEL

COMPATIBLE WITH

K01-BACNET

SUITE* ZEN AMAZON

*Except for wall-mounted and KSD units.

INSTALLATION EXAMPLE

K01-BACNET

OUTDOOR UNITS K1,K2,E

INDOOR UNITS P,Q,E

XYE

HUB OUTDOOR UNITS

XYE

WITH IP Motorised System

276 276

BMS

BACNET PROTOCOL IP

INDOOR UNITS

P,Q,E


Inspiration, Innovation, Evolution

K01-KNX GENERAL CHARACTERISTICS • BMS interface, direct gateway to KNX. • Centralised controllers not required. • Three interface types, 1, 16 or 64 indoor units.

MODEL

COMPATIBLE WITH

KO1-KNX 1

SUITE* ZEN AMAZON

KO1-KNX 16 KO1-KNX 64 *Except for wall-mounted and KSD units.

INSTALLATION EXAMPLE INDOOR UNITS P.Q.E

P.Q.E

P.Q.E

KO1-KNX 1

XYE

KO1-KNX 1

CONTROL SYSTEMS

KO1-KNX 1

XYE

CONTROLS

XYE

OUTDOOR UNIT KNX CONTROL SYSTEM

277


CONTROL SYSTEMS RANGE BMS AND SOFTWARE

BMS AND SOFTWARE K01-WIFI GENERAL CHARACTERISTICS • The user connects via a web page or APP for IOS or Android and controls the air-conditioning units in an easy and intuitive way. A cloud server manages the whole process. • Centralised controllers not required. • Designed for controlling juts one unit. • Collaboration agreement with Intesis Home.

MODEL

COMPATIBLE WITH SUITE ZEN AMAZON

K01-WIFI

*INFRARED DEVICE

INSTALLATION EXAMPLE 1

2

SMARTPHONE

PC

TABLET

THE COMMAND IS SENT FROM OUR DEVICE

INFORMATION IS TRANSFERRED THROUGH THE CLOUD SERVER

3

4

+ 1

2

1 K01-WIFI device 2 External antenna A CONVENTIONAL ROUTER RECEIVES THE COMMAND IT SENDS THE SIGNAL TO OUR UNITS

278 278

THE INDOOR UNIT RUNS THE COMMAND


Inspiration, Innovation, Evolution

REMOTE CONTROLLER OF YOUR AIR CONDITIONER

K01-WIFI

ADVANTAGES

+

TURN YOU EQUIPMENT ON AND OFF

+

CHANGE THE FUNCTION (HEAT, COOL, DRY...)

+

CONTROL THE POSITION OF THE LOUVRES

+

DISPLAY THE TEMPERATURE IN YOUR HOUSE

SMARTPHONE

PC

TABLET

INSTANT CONTROL ANYWHERE

¿HOW DOES IT WORK?

Switch on the Air Conditioning before arriving home.

Change the automatic switch on programme if you are going to arrive later.

Know the temperature in the rooms of your house at all times. CONTROL SYSTEMS

Control all the Air Conditioning units via the Internet from a website or from an application for your Smartphone or Tablet.

CONTROLS

WHAT DO YOU NEED? You only need to install a small device into your air-conditioning unit to begin remotely controlling your units. The WIFI router at your place will send your commands.

DOES IT TAKE UP SPACE ON MY OPERATION INTERFACE EXAMPLE

MOBILE DEVICE? No! All the information necessary for the operation of the new K01-WIFI control is stored in the cloud during the process. 279


CONTROL SYSTEMS RANGE BMS AND SOFTWARE

BMS AND SOFTWARE KAYNET CONTROL GENERAL CHARACTERISTICS • A KAYSUN solution for a comprehensive control of your units. • Up to 16 cooling circuits. • Up to 256 indoor units. • Up to 64 outdoor units. • Centralised controllers not required. • Simple Web control though IP or software. • Network control software included. MODEL

COMPATIBLE WITH SUITE* AMAZON ZEN

KAYNET CONTROL *Except for wall-mounted and KSD units.

INSTALLATION EXAMPLE PC KAYNET CONTROL

4

XYE KIK2E INDOOR UNITS

PQE

XYE KIK2E INDOOR UNITS

PQE

XYE KIK2E

INDOOR UNITS

PQE

XYE KIK2E

INDOOR UNITS

PQE

280 280

PC UP TO 4 KAYNET CONTROLS


SCHEDULE

GROUPS

LIMITATION/BLOCK

BUILDING LAYOUT

CONSUMPTION CONTROL AND RECORD

START AND STOP RECORD

COMMANDS AND ACCESSES RECORD

CONTROLS

MAIN DISPLAY

CONTROL SYSTEMS

Inspiration, Innovation, Evolution

281


CONTROL SYSTEMS RANGE ACCESSORIES.

ACCESSORIES. KAHU GENERAL CHARACTERISTICS • Interface to connect a cooling unit with a direct expansion coil to the AMAZON (VRF) systems. • It has an additional indoor unit. • Power from 9 to 56 kW. • More than one unit can be connected at the same time to increase the connectable power.

MODEL

COMPATIBLE WITH

KAHU-200.2 KAHU-360.2

AMAZON

KAHU-560.2

INSTALLATION EXAMPLE

KAHU

OUTDOOR UNIT

PQE Liquid cooling pipeline

Gas cooling pipeline

MARKET CLIMATE CONTROL WITH DIRECT EXPANSION BATTERY

282

INDOOR UNITS


Inspiration, Innovation, Evolution

K01-WATT GENERAL CHARACTERISTICS • Digital wattmeter. • One controller for each outdoor module. • Consumption can be displayed through the KMC-32 E and KAYNET control.

MODEL

COMPATIBLE WITH

K01-WATT

AMAZON*

*Except for MINIAMAZON II systems.

INSTALLATION EXAMPLE OUTDOOR UNITS

INDOOR UNITS

O, A, E PORT

O, A, E PORT

O, A, E PORT

O, A, E PORT

PQE

CONTROLS

CONTROL SYSTEMS

KO1-WATT KO1-WATT KO1-WATT KO1-WATT

283


CONTROL SYSTEMS RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

CASA ÁRABE PUBLIC BUILDING Location: Madrid Units installed: KAYNET

KAYSUN AND THE LATEST TECHNOLOGY GO HAND IN HAND AS IT FORGES AHEAD TO OFFER THE BEST IN AIR-CONDITIONING CONTROL UNITS. INSPIRATION, INNOVATION AND PROGRESS ARE REFLECTED IN THIS RANGE, BRINGING THE NEWEST LOOK AND BEST FEATURES TO ALL OF OUR CONTROL DEVICES.

284


Inspiration, Innovation, Evolution

KOMKAL INDUSTRIAL BUILDING

Location: Reus (Tarragona) Units installed: MODBUS

DOLCE FREGATE

CONTROLS

CONTROL SYSTEMS

HOTEL

Location: Provence (France) Units installed: KAYNET

285


NEXUS CHILLERS RANGE

INTRODUCTION TO THE PRODUCT RANGE.......................................................... ..288 CHILLERS..........................................................................................................................292 MINICHILLERS FULL DC INVERTER...............................KEM D(V)(T)N........... ..294 MODULAR FULL DC INVERTER CHILLERS....................KEM DNS3................ ..296 FULL DC INVERTER CHILLERS WITH HYDRAULIC KIT.......................................................KEM DNS3 KH.......... ..298 FIXED SCROLL MODULAR CHILLERS.............................KEM HN3..................... 300 EXTERNAL HYDRAULIC KITS..........................................KH.............................. ..302 ROTARY SCREW CHILLERS.................................................................................. 304 CENTRIFUGAL CHILLERS...................................................................................... 306 KEY INSTALLATIONS................................................................................................... 308


NEXUS NEXUS CHILLERS

CHILLERS RANGE


CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

NEXUS CHILLERS RANGE

The new 2018 KAYSUN chillers range has a wide range of units to meet each and every requirement of any premises. The KAYSUN Nexus series is the ideal solution for spaces that require climate control, such as homes, hotels, offices, stores and other facilities. All units in this range use environmentally and ozone-friendly refrigerant.

“THE FLOW OF THE MOST ADVANCED TECHNOLOGY”

MODULAR CHILLERS KAYSUN offers an extensive range of modular units with great versatility thanks to its combinable basic modules. Both design and installation process of this units are highly flexible, adding and combining chillers according to the needs of any customer or premises.

REFRIGERANT INLET

MODULAR FULL DC INVERTER CHILLERS New modular 30kW and 60kW chillers fitted with Full DC Inverter technology. Up to four modules of these units can be combined, allowing us to achieve capacities of up to 240 kW. Fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and high energy savings. Compact structure units designed for convenient access and maintenance.

WATER INLET

REFRIGERANT OUTLET

HOT PLATE

WATER OUTLET

EXCHANGER TYPE Full DC Inverter chillers are fitted with a plate heat exchanger.

288

+

TWIN ROTARY DC INVERTER COMPRESSORS

+

DC INVERTER VENTILATORS

+

COMPACT STRUCTURE


Inspiration, Innovation, Evolution

FIXED SCROLL The 130kW, 185kW and 250kW fixed Scroll chillers, can be also combined with four 250 kW units, thereby achieving 1MW of maximum cooling power.

x4

COMBINABLE UP TO 1000 kW

EXCHANGER TYPE Fixed Scroll Chillers are fitted with a multitubular heat exchanger. Multitubular System GAS OUTLET

GAS INLET

WATER INLET

WATER OUTLET

FULL DC INVERTER CHILLER UNITS WITH BUILT-IN HYDRAULIC KIT 30kW and 60 kW Full DC Inverter Chillers with incorporated hydraulic kit. These units are fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and the resulting energy savings. Compact structure units designed for convenient access and maintenance.

TWIN ROTARY DC INVERTER COMPRESSORS

+

DC INVERTER FAN MOTORS

+

COMPACT STRUCTURE

+

BUILT-IN HYDRAULIC KIT

NEXUS CHILLERS

+

289


CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

FULL DC INVERTER MINICHILLERS Minichiller units with 12, 14 and 16 kW rotary Inverter compressors provide up to 3.39 EER and up to 3.50 COP. This enhancement turns these units into a very efficient option to be considered for residential hot water installations.

REFRIGERANT INLET

WATER INLET

REFRIGERANT OUTLET

WATER OUTLET

HOT PLATE

EXCHANGER TYPE These units are fitted with a plate exchanger.

HYDRAULIC KIT INVERTER MINICHILLERS

Minichiller units are delivered with a complete built-in hydraulic kit.

ROTARY SCREW CHILLERS KAYSUN’SNEXUS range has large chillers with screw compressors. These units can operate condensed by air or water. Besides, all units are fitted with Bitzer bi-screw compressors and regulate refrigerant through an electronic expansion valve. These units have a capacity of between 340 and 1780 kW. They also incorporate multi-tubular evaporators and control is carried out using a microprocessor with a 10.7” touchscreen.

CENTRIFUGAL CHILLERS KAYSUN introduces its most powerful range of chillers, thanks to to the addition of centrifugal compressors.. They are available in three different options according on their efficiency. From standard units to high-efficiency and, eventually, super high-efficiency units, with 7.11 EER.

290


Inspiration, Innovation, Evolution

UNITS

NEXUS NEXUS CHILLERS CHILLERS

TECHNICAL SPECIFICATIONS

291


CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

POWER RANGE

FULL DC INVERTER MINICHILLERS POWER

kW

(Page 294)

5

7

10

12

KEM-7 DVN1

KEM-10 DVN

KEM-12 DVN

14

16

20

25

KEM-12 DTN

KEM-14 DTN

KEM-16 DTN

12

14

16

20

25

200

225

250

300

350

690

720

SINGLE-PHASE KEM-5 DVN1

TRI-PHASE

MODULAR FULL DC INVERTER CHILLERS

POWER kW

(Page 296)

5

7

10

WITHOUT HYDRAULIC KIT

WITH HYDRAULIC KIT

FIXED SCROLL MODULAR CHILLERS

POWER kW

130

180

(Page 300)

COMBINABLE UP TO 4 MODULES KEM-130 HN3

CHILLERS SCREW

POWER kW

340

380

KEM-200 HN3

440

500

KEM-250 HN3

540

600

(Page 304)

AIR-WATER CONSULT MODEL

WATER-WATER CONSULT MODEL

CHILLERS CENTRIFUGAL

2

MW

3

4

(Page 306)

HIGH CAPACITY CONSULT MODEL

292

5


Inspiration, Innovation, Evolution

30

35

40

45

50

55

60

65

30

35

40

45

50

55

60

65

COMBINABLE UP TO 4 MODULES KEM-30 DNS3

KEM-60 DNS3

KEM-30 DNS3 KH

KEM-60 DNS3 KH

400

450

500

550

600

650

700

750

805

890

900

1000

1080

1200

1385

1400

1620

1780

CONSULT MODEL

6

7

8

NEXUS CHILLERS

CONSULT MODEL

9

CONSULT MODEL

293


CHILLERS RANGE MINICHILLERS

MINICHILLERS FULL DC INVERTER TECHNICAL SPECIFICATIONS INVERTER

KEM-5 DVN1 KEM-7 DVN1 KEM-10 DVN KEM-12 DVN KEM-12 DTN KEM-14 DTN KEM-16 DTN

MODEL Power Cooling capacity Cooling input

V-FHz kW

220/1/~50

220/1/~50

220/1/~50

220/1/~50

380/3/~50

380/3/~50

380/3/~50

5 (1.9 ~ 5.8)

7 (2.1 ~ 7.8)

10.0 (2.9 ~ 10.5)

11.2 (3.1 ~ 12.0)

11.2 (3.1 ~ 12.0)

12.5 (3.3 ~ 14.0)

14.5 (3.5 ~ 15.5)

kCal/h

4300

6020

8600

9632

9632

10750

12470

kW

1.55

2.25

2.95

3.5

3.38

3.9

4.7

3.23

3.11

3.39

3.20

3.31

3.20

3.10

kW

6.2 (2.1 ~ 7.0)

8 (2.3 ~ 9.0)

11.0 (3.2 ~ 12.0)

12.3 (3.3 ~ 13.2)

12.3 (3.3 ~ 13.2)

13.8 (3.5 ~ 15.4)

16.0 (3.7 ~ 17.0)

kCal/h

5330

6880

9460

10578

10578

11868

13760

kW

1.9

2.5

3.14

3.78

3.72

4.25

4.85

3.26

3.20

3.50

3.25

3.31

3.25

3.30

Rotary

Rotary

Rotary

Rotary

Rotary

Rotary

Rotary

1

1

1

1

1

1

1

EER Heating Capacity Heating input COP Compressor type No. of compressors Water flow rate

m3/h

0.86

1.2

1.72

1.92

1.92

2.15

2.49

Max./min. water flow

m3/h

0.95/0.77

1.32/1.08

1.89/1.54

2.11/1.73

2.11/1.72

2.36/1.93

2.73/2.24

Max./min. water pressure

kPa

500/150

500/150

500/150

500/150

500/150

500/150

500/150

Refrigerant charge (R410A)

Kg

2.5

2.5

2.8

2.8

2.8

2.9

3.2

1

1

2

2

2

2

2

W

170

170

2x100

2x100

2x100

2x100

2x100

Dim. deep / wide / high

mm

354x990x966

354x990x966

Weight

Kg

81

81

110

110

110

111

111

dB (A)

58

58

59

59

59

60

60

Hydraulic connections

mm

DN25 (1")

DN25 (1")

DN32 (1 1/4")

DN32 (1 1/4")

DN32 (1 1/4")

DN32 (1 1/4")

DN32 (1 1/4")

Load loss evaporator

kPa

15

15

18

18

18

18

19

Axial fan Fan input power

Sound pressure

400x970x1327 400x970x1327 400x970x1327 400x970x1327 400x970x1327

Working Range

ºC

Cooling -5 ~ 46 / Heating -15 ~ 27

Supply water temperature

ºC

Cooling 4 ~ 20 / Heating 30 ~ 55

Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

294


Inspiration, Innovation, Evolution

DC R410A

INVERTER

!

DC

INVERTER

KIT

OUTDOOR

GENERAL CHARACTERISTICS Full DC Inverter Minichillers from 5 to 16 kW: Dry contacts for start/stop, cold/heat and alarm. Connection ports for additional water pump and optional wired controller.

+

COMPACT DESIGN AND EASY INSTALLATION

+

AUTO-RESTART FEATURE

+

CONTROLLER INCLUDED

+

COMPLETE HYDRAULIC KIT

INVERTER MINICHILLERS

• • • • •

On/Off Mode selector Temp. set Timer Diagnosis

KCCHT-03 Optional wired controller fitted with: • Touch control and LCD display. • Weekly timer. • Real-time clock

NEXUS CHILLERS

STANDARD CONTROLLER

295


CHILLERS RANGE FULL DC INVERTER CHILLERS

MODULAR FULL DC INVERTER CHILLERS TECHNICAL SPECIFICATIONS BASIC MODULES

MODEL Module 30 + Module 60 Power Cooling capacity Cooling input power

Heating input power

KEM-60 DNS3

KEM-90 DNS3

1+0

0+1

1+1

0+3

1+3

0+4

kW

27

55

82

110

137

165

192

220

23215

47300

70515

94600

117815

141900

165115

189200

kW

10.8

22

32.8

44

54.8

66

76.8

88

4.41

4.2

4.31

4.2

4.27

4.2

4.23

4.2

kW

31

61

92

122

153

183

214

244

kCal/h

26700

52500

79100

104900

131600

157400

184000

209800

kW

10.5

20.3

30.8

40.6

51.1

60.9

71.4

81.2

4.01

3.85

3.93

3.85

3.9

3.85

3.87

3.85

1

2

3

4

5

6

7

8

5

6

7

8

4%

4%

3%

3%

No. of compressors Compressor type

Double Twin Rotary DC

Number of cooling circuits %

1

2

3

4

10%

10%

4%

5%

Evaporator Evaporator pressure drop

1+2

380-415/3/40

kCal/h

SCOP

Minimum total capacity

KEM-120 KEM-150 KEM-180 KEM-210 KEM-240 DNS3 DNS3 DNS3 DNS3 DNS3 0+2

V-f-Hz

SEER Heating Capacity

KEM-30 DNS3

Plates kPa

60

80

80

80

80

80

80

80

Water flow

m3/h

5

9.8

14.55

19.6

24.35

29.4

34.15

39.2

Min./max. water flow

m3/h

3.5~5.7

7.5~12

11~17.7

15~24

18.5~29.7

22.5~36

26~41.7

30~48

Max. water pressure

MPa

1

1

1

1

1

1

1

1

2" (DN50)

-

-

-

-

-

-

Hydraulic connections

Inches (mm) 11/2" (DN40)

Capacitor

Blades

Number of condensers Air flow

m3/h

1

2

3

4

5

6

7

8

12500

24000

36500

48000

60500

72000

84500

96000

Control system included Refrigerant load (R410A)

KCCHT-04 MODBUS wired controller Kg

Number of axial ventilators

10.5

17

27.5

34

44.5

51

61.5

68

1

2

3

4

5

6

7

8

0.45

0.6 (x2)

1.65 (total)

2.4 (total)

2.85 (total)

3.6 (total)

4.05 (total)

4.8 (total)

Fan input power

kW

Dimensions (depth/width/height)

mm

Weight

Kg

300

480

780

960

1260

1440

1740

1920

Sound pressure

dB (A)

65.8

72.1

73

75.1

75.6

76.9

77.5

78.6

Working Range

ºC

Cooling -15~52 / Heating -15~30

Supply water temperature

ºC

Cooling 0~20 / Heating 25~55

1870/1000/ 2200/1035/ 2200/2035/ 2200/2070/ 2200/3070/ 2200/3105/ 1175 1325 1460 1460 1460 1460

Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

296

2200/4105/ 2200/4140/ 1460 1460


Inspiration, Innovation, Evolution

DC R410A

INVERTER

!

GENERAL CHARACTERISTICS

The Full DC Rotary Inverter compressor and Full DC brushless ventilators provide great stability and energy efficiency.

Full DC Inverter: The technology used in the Kaysun DC INVERTERS optimises consumption, adjusting with greater accuracy to the actual demand of the system.

Self-protection and self-diagnosis functions: Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.

Automatic control: A single control for all the models that form the system.

Dry contacts for start/stop, cold/ heat and alarm.

Condensation control.

The units are very compact and are designed to speed up maintenance. Up to 4 modules can be combined, reaching a capacity of 240 kW.

1

CONTROLLER ONLY FOR AUTOMATIC CONTROL

+

STANDARD MODBUS PROTOCOL GATE

KCCHT-04 MODBUS STANDARD CONTROLLER

NEXUS CHILLERS

Kaysun Full DC INVERTER CHILLERS are available in two types of module: a 30 kW module and a 60 kW module.

297


CHILLERS RANGE FULL DC INVERTER CHILLERS

FULL DC INVERTER CHILLERS WITH HYDRAULIC KIT TECHNICAL SPECIFICATIONS KEM-30 DNS3 KH

MODEL Power Cooling capacity Cooling input power

V-f-Hz

Heating input power

380-415/3/50

kW

27

55

kCal/h

23215

47300

kW

12

23.2

3.72

3.73

kW

31

61

kCal/h

26650

52450

kW

11.7

21.5

3.43

3.45

1

2

SEER Heating Capacity

SCOP Number of compressors Compressor type Minimum total capacity

KEM-60 DNS3 KH

Double Twin Rotary DC

%

10%

10%

Plates

Plates

kPa

60

80

Water flow

m³/h

5

9.8

Min./max. water flow

m³/h

3.8-6.4

8-13

Max. water pressure

Mpa Inches (mm) m³/h

1

1

1 1/2" (DN40)

2" (DN50)

12500

24000

Evaporator Evaporator pressure drop

Hydraulic connections Air flow Control system included Refrigerant load (R410A)

KCCHT-04 MODBUS

Kg

Number of axial ventilators

10.5

17

1

2

Fan input power

kW

0.45

0.6 x 2

Dimensions (depth/width/height)

mm

1870/1175/1000

2200/1325/1055

Weight

Kg

335

515

Sound pressure

dB

68

73

Pump pressure

mca / kPa

32 / 314

Pump flow rate

m³/h

At 27.1 mca, for a flow rate of 10 m3/h. (± 10%)

Expansion tank

L

Working Range

ºC

Cooling -15~52 / Heating -15~30

Supply water temperature

ºC

Cooling 0~20 / Heating 25~55

4.2

Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

298

12


Inspiration, Innovation, Evolution

DC R410A

INVERTER

!

KIT

GENERAL CHARACTERISTICS Kaysun Full DC INVERTER CHILLERS WITH HYDRAULIC KIT are available in two types of module: a 30 kW module and a 60 kW module.

Full DC Inverter: The technology used in the Kaysun DC INVERTERS optimises consumption, adjusting with greater accuracy to the actual demand of the system.

The Full DC Rotary Inverter compressor and Full DC brushless ventilators provide great stability and energy efficiency.

Self-protection and self-diagnosis functions: Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.

Automatic control: A single control for all the models that form the system.

Dry contacts for start/stop, cold/ heat and alarm.

Condensation control.

Full built-in hydraulic kit.

The units are very compact and are designed to speed up maintenance. These units include a built-in hydraulic kit.

1

CONTROLLER ONLY FOR AUTOMATIC CONTROL

+

STANDARD MODBUS PROTOCOL GATE

KCCHT-04 MODBUS STANDARD CONTROLLER

Venting system

Safety valve

Plate exchanger

Accumulator

HYDRAULIC KIT INCORPORATED

NEXUS CHILLERS

+

Water outlet

Water pump

Expansion tank

Liquid separator

299


CHILLERS RANGE FIXED SCROLL MODULAR CHILLERS

FIXED SCROLL MODULAR CHILLERS TECHNICAL SPECIFICATIONS MODEL Power Cooling capacity Cooling input

V-f-Hz

KEM-130 HN3

KEM-200 HN3

KEM-250 HN3

380/3/~50

380/3/~50

380/3/~50

kW

130

185

250

kCal/h

111800

159100

215000

kW

40.8

63

78.3

ESEER

3.13

3.07

3.06

kW

138

200

270

kCal/h

118680

172000

232200

kW

43

61

80

3.09

2.92

2.90

No. of compressors

4

6

8

No. of cooling cycles

4

6

4

25

17

25

Multitube

Multitube

Multitube

kPa

25

30

40

Water flow

m3/h

22.4

31.8

43

Min./max. water flow

m3/h

18.54/22.66

27.90/34.10

38.70/47.30

Max. water pressure

MPa

1

1

1

Inches (mm)

2 1/2" (DN65)

3" (DN80)

Heating Capacity Heating input COP

Min. total capacity

%

Evaporator Evaporator pressure drop

Hydraulic connections Capacitor Air flow

Aluminium blades m3/h

48000

Control system included Refrigerant charge (R410A)

4" (DN100) 33

72000

96000

KCCHT - 02 wired controller Kg

No. of axial fans

7x4

7x6

15x4

4

6

8

Fan input power

kW

0.865x4

0.865x6

0.7x8

Dimensions (depth/width/height)

mm

1685x2000x2080

2000x2850x2110

2000x3800x2130

Weight

Kg

1150

1730

2450

Sound pressure

dB (A)

70

74

74

Working Range

ºC

Cooling -10 ~ 46 / Heating -10 ~ 21

Supply water temperature

ºC

Cooling 0 ~ 17 / Heating 22 ~ 50

(*) Measurement at 1 m distance and 1.5 m height. Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

300


Inspiration, Innovation, Evolution

!

R410A

DIGITAL

GENERAL CHARACTERISTICS The KAYSUN NEXUS range continues to grow and completes its range of chillers with new fixed Scroll compressor modular units of 130, 200 and 250kW each, thereby providing great solutions designed to cover the needs of our customers. Equipped with 4, 6 and 8 compressors respectively, a "V"-type condensing coil and a multi-tube heat exchanger, these units provide a better capacity reach for the KAYSUN NEXUS range units. Just as versatile as lesser capacity units, these fixed Scroll compressor modular chillers can form modules of up to 4 units, arriving to capacities of 1000 kW.

Flexible combination: the connection between modules is as simple as connecting each of their inlet and outlet tubes.

Self-protection and self-diagnosis functions: Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.

Automatic control: A single control for all the models that form the system.

Dry contacts for start/stop, cold/ heat and alarm.

Condensation control.

Anti-icing function.

KCCHT-02 STANDARD CONTROLLER

x4

COMBINABLE UP TO 1000 kW

SINGLE BMS AND SOFTWARE NEXUS CHILLERS

INDIVIDUAL

KCCH-02 PS* *Includes weekly programmer

KCCHT-02

K01-LON KEM

K01- BACNET KEM* *Included only with KCCH-02 PS

KCCHT-02 MODBUS

301


CHILLERS RANGE HYDRAULIC KITS

EXTERNAL HYDRAULIC KITS TECHNICAL SPECIFICATIONS KHX-A-300

KHX-B-300

KHX-C-300

KHX-D-500

KHX-F-500

litres

300

300

300

500

500

bar

3

3

3

3

3

1

1

1

1

1

m3/h mca kW Inches V/f/Hz

11.18

16.4

22.4

27.6/31.8/33.6

38.8/43/44.8

17

17.7

14.4

18.8/17.3/16.6

18.4/17.7/17.3

1.1

1.5

1.5

2.2

3

2 1/2"

2 1/2"

2 1/2"

2 1/2"

3"

400/3/50

400/3/50

400/3/50

400/3/50

400/3/50

mm

1265x1504x1120

1265x1504x1120

1265x1504x1120

1265x1504x1120

1265x1504x1120

MODEL (WITH BUFFER TANK) + 1 PUMP Buffer tank capacity Pressure relief valve calibration No. of pumps Pump flow Pressure loss Power input Hydraulic connections Power Dimensions Height / Width / Depth Net weight Gross weight (with water)

Kg Kg Capacity litres Expansion Tank included* Calibration Pressure bar

MODEL (WITH BUFFER TANK) + DOUBLE PUMP Buffer tank capacity Pressure relief valve calibration No. of pumps Pump flow Pressure loss Power input Hydraulic connections Power Dimensions Height / Width / Depth Net weight Gross weight (with water)

188

188

213

341

488

488

713

841

25

25

25

25

25

1.5

1.5

1.5

1.5

1.5

KH2X-A-300

KH2X-B-300

KH2X-C-300

KH2X-D-500

KH2X-F-500

litres

300

300

300

500

500

bar

3

3

3

3

3

2

2

2

2

2

m3/h mca kW Inches V/f/Hz

11.18

16.4

22.4

27.6/31.8/33.6

38.8/43/44.8

17

17.7

14.4

18.8/17.3/16.6

18.4/17.7/17.3

1.1

1.5

1.5

2.2

3

2 1/2"

2 1/2"

2 1/2"

2 1/2"

3"

400/3/50

400/3/50

400/3/50

400/3/50

400/3/50

mm

1265x1504x1120

1265x1504x1120

1265x1504x1120

1265x1504x1120

1265x1504x1120

Kg Kg Capacity litres Expansion Tank included* Calibration Pressure bar

MODEL (WITHOUT BUFFER TANK) + 1 PUMP Buffer tank capacity Pressure relief valve calibration No. of pumps Pump flow Pressure loss Power input Hydraulic connections Power Dimensions Height / Width / Depth Net weight

186 486

litres bar

216

220

220

247

428

516

520

520

747

928

25

25

25

25

25

1.5

1.5

1.5

1.5

1.5

KHX-A

KHX-B

KHX-C

KHX-D

KHX-F

-

-

-

-

-

3

3

3

3

3

1

11.18 m3/h 17 mca 1.1 kW 2 1/2" Inches 400/3/50 V/f/Hz mm 1350x800x650 89 Kg 12 litres Expansion Tank Capacity included* 1.5 Calibration Pressure bar

1

1

1

1

16.4

22.4

27.6/31.8/33.6

38.8/43/44.8

17.7

14.4

18.8/17.3/16.6

18.4/17.7/17.3

1.5

1.5

2.2

3

2 1/2"

2 1/2"

2 1/2"

3"

400/3/50

400/3/50

400/3/50

400/3/50

1350x800x650

1350x800x650

1350x800x650

1350x1120x800

90

91

93

12

12

12

25

1.5

1.5

1.5

1.5

*Hydraulic kits include a standard expansion tank. In case that you want a different type of tank (see next page), lease inform the Sales Department.

302

153


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS

1. Inertia tank 2. Water pump 3. Expansion tank 5. On-off valve 6. Safety valve 7. Pressure gauge 8. Automatic venting system 10. Automatic filling unit 11. Electric panel

CHILLERS Compatible hydraulic kits*

CHILLERS Compatible hydraulic kits*

12. Check valve (version with 2 pumps only) 13. Drain 14. Anchor points (no. 4-6 holes M12/Ø14) 15. Power Supply 16. Hoist points 17. Supply pipeline 18. Discharge pipeline

KEM-60 DNS3

KEM-120 DNS3

KEM-130 HN3

KEM-150 DNS3

KEM-180 DNS3

KHX-A

KHX-C

KHX-C

KHX-D

KHX-D

KHX-A-300

KHX-C-300

KHX-C-300

KHX-D-500

KHX-D-500

KH2X-A-300

KH2X-C-300

KH2X-C-300

KH2X-D-500

KH2X-D-500

KEM-200 HN3

KEM-210 DNS3

KEM-240 DNS3

KEM-250 HN3

KHX-D

KHX-F

KHX-F

KHX-F

KHX-D-500

KHX-F-500

KHX-F-500

KHX-F-500

KH2X-D-500

KH2X-F-500

KH2X-F-500

KH2X-F-500

(*)These application tables are for guidance purposes only. The final decision is to be made by the installer.

12 L Expansion Vessel

25 L Expansion Vessel

2 x 25 L Expansion Vessel 3 x 25 L Expansion Vessel

Capacity

litres

12

25

50

75

Calibration Pressure

bar

1.5

1.5

1.5

1.5

NEXUS CHILLERS

OPTIONAL EXPANSION VESSELS

303


CHILLERS RANGE ROTARY SCREW CHILLERS

AIR COOLED SCREW CHILLERS KAYSUN air cooled screw chillers are designed to meet all the requirements and standards related to reliability, energy efficiency and smart control. For this purpose, they are fitted with the best technologies available nowadays: Bitzer screw compressor, High precision electronic expansion valves, condensers optimised for maximum efficiency and heat exchange, high performance multitubular evaporator, and so on.

A COST EFFECTIVE TOOL FOR YOUR HOME

COST-EFFECTIVE OPERATION

• High reliability equipment.

• High energy efficiency.

• High quality components: Bitzer, Danfoss, Schneider Electric, etc.

• Based on AHRI 550/590 standard; the unit works partially loaded 99% of its working hours.

• All units have undergone extensive testing to ensure perfect operation, in facilities that are a worldwide standard.

• Optimized performance on partial loads between 50%~75%. • Easy service, low maintenance costs.

• Easy and fast installation process.

QUIET OPERATION • Impellers designed to reduce noise. • Smart control logic that balances fan’s performance and operation. • Super low noise model (optional).

ENVIRONMENTAL RESPONSIBILITY • Its high efficiency also means less consumption, which reduces gas emissions. • R-134A refrigerant, ozone-depleting potential free.

SMART CONTROL • Controlled by integrated microprocessor with touch screen. • Gateway to communication protocols and BMS. • Own software for selecting and managing the chiller.

INVERTED "M"-SHAPED AIR CONDENSER

M

KAYSUN screw chillers are the ideal choice for schools, hospitals, shopping malls, office buildings, factories and large installations in general.

304


Inspiration, Innovation, Evolution

WATER COOLED SCREW CHILLERS KAYSUN water cooled screw chillers include a flooded multitubular evaporator and a high efficiency multitubular condenser. They are also equipped with high-precision electronic expansion valves and Bitzer semi-hermetic twin-screw compressors, which means maximum efficiency both at full load and partial loads. Each chiller is fully tested before delivery.

A COST EFFECTIVE TOOL FOR YOUR HOME

ENVIRONMENTAL RESPONSIBILITY

• High reliability equipment.

• Its high efficiency also means less consumption, which reduces gas emissions.

• The best components, technologies such as triple stage oil separation to ensure perfect lubrication of the compressor. • All units have undergone extensive testing to ensure perfect operation, in facilities that are a worldwide standard. • Easy and fas installation process.

• R-134A refrigerant, ozone-depleting potential free.

SMART CONTROL • Controlled by integrated microprocessor with touch screen. • Gateway to communication protocols and BMS.

COST-EFFECTIVE OPERATION • High energy efficiency.

• Own software for selecting and managing the chiller.

• Easy service, low maintenance costs.

NEXUS CHILLERS

1. Input 2. Motor 3. Screw 4. Poppet valve 5. Output 6. Oil separator 7. Bearing 8. Electric resistance of the oil pan 9. Oil filter

KAYSUN water condensed screw chillers are the ideal choice for shopping centres, hospitals, factories, and large air conditioning and comfort installations. Its applications also extend to the plastics industry, the plating industry, food processing, the chemical industry and other processing facilities that require large amounts of cold water.

305


CHILLERS RANGE ROTARY SCREW CHILLERS

CENTRIFUGAL CHILLERS CHILLERS RANGE KAYSUN introduces its most powerful range of chillers, thanks to the addition of centrifugal compressors.

“THE HIGHEST POWER AT YOUR SERVICE"

They are available in three different options according on their efficiency. From standard units to high-efficiency and, eventually, super high-efficiency units, with 7.11 EER. All our units use R134a, an environmentally friendly refrigerant with a low GWP (Global Warming Potential), which results in maximum performance.

STANDARD EFFICIENCY The Standard Efficiency range units are available with two different type of configurations. One consists of a power range between 1.58MW to 4.22MW, a single compression stage and a flooded multi-tube type evaporator. The second configuration consists of two stages and a full falling film multitubular evaporator, which results in higher cooling power, from 4.57 MW to 7.73 MW. All these units provide between 5.3 and 5.7 EER.

WHAT IS "FULL FALLING FILM"? It is the latest in refrigerant savings systems. This new concept allows using 40% less refrigerant than the traditional flooded multitube type evaporator, and increases the energy exchange rate between 3% and 8%.

ED

T EN

T PA

HOW DOES IT WORK? The refrigerant falls in a liquid state in the form of rain between the tubes. As it falls through several levels, the refrigerant evaporates.

40% reduction in refrigerant charge

Flooded type The falling film reaches around 40% of the refrigerant charge compared with the flooded type.

306

Full falling film Almost 0% of liquid level

This way, only a small percentage of refrigerant reaches the bottom of the evaporator.


Inspiration, Innovation, Evolution

HIGH EFFICIENCY High efficiency chillers are one-step ahead. They are divided into two different configurations. One consists of a onestage centrifugal compressor and a flooded evaporator, which results in a power range from 2.46MW to 4.22MW. The second configuration consists of a two-stage compressor and an evaporator including the Full Falling Film system. High Efficiency units provide from 5.6 to 6.8 EER.

CONTROL PANEL All centrifugal units are fitted with an easy to access control panel. They also include a 10.4 inches LCD touch screen to display graphic views of the chiller. The screen is easy to access. It communicates with PCs, starts and stops the unit remotely and provides more than 30 protection functions that can be checked in the 10 last failure reports.

SUPER HIGH EFFICIENCY The Kaysun Super High Efficiency RANGE, include units with 7.11 EER, which turns them into the most efficient product in the market, considering their performance. These units can reach up to 7.73 MW with a two-stage centrifugal compressor fitted with a multi-tube evaporator including the new full falling film system.

GUARANTEE OF SUCCESS

NEXUS CHILLERS

IN ORDER TO ensure the perfect operation of its high-capacity chillers, Kaysun performs tests on all of its units. This way, the company is able to guarantee that its products will comply with all the established requirements.

307


CHILLERS RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

GADIS SUPERMARKET COMMERCIAL BUILDING Location: Oleiros - Coruña Initial situation: New construction Units installed: Nexus Capacity: 195 kW

308


NEXUS CHILLERS

Inspiration, Innovation, Evolution

309


CHILLERS RANGE KEY INSTALLATIONS

THE NEXUS RANGE REPRESENTS KAYSUN'S COMMITMENT TO ENVIRONMENT. THANKS TO ITS WIDE RANGE OF DIMENSIONS AND CAPACITIES, NEXUS CHILLERS ADAPT TO EVERY TYPE OF SPACE. HOTELS, OFFICES AND BUSINESS CENTRES CHOOSE THIS RANGE AS THEIR ALLY IN THE AIR-CONDITIONING OF THEIR INSTALLATIONS.

FOSTERS HOLLYWOOD RESTAURANT

Location: Gijón Initial situation: New construction Units installed: Nexus, Zen Capacity: 90 kW

OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN NEXUS HOTELS Al-Mirab Hotel (Córdoba), Calabera Hotel (Huelva), Marina Luz Hotel (Palma de Mallorca), Ambos Mundos Hotel (Palma de Mallorca), Mac Hotels (Palma de Mallorca), Paraiso Hotel (Málaga), Gran Palladium Resort (Ibiza), Ruta Jacobea Hotel (Santiago Compostela), Alcotan Hotel (San Pedro de Alcantara), Orly Hotel (Camponaraya, León). PUBLIC BUILDINGS Baza City Council (Granada), Caracoles Building -

310

Chamartin Railway Station (Madrid), 091 Emergencies Headquarters (Málaga), Madrid Underground Headquarters (Madrid), Barakaldo City Council (Bizkaia), T2 Terminal AENA Airport (Barcelona). SCHOOLS AND UNIVERSITIES San Luis School (Menorca), Camino de Gelves Nursery School (Seville), María de la Salud State School (Majorca) HOSPITALS, CLINICS AND HEALTH CENTRES San Juan de Dios Clinic (Málaga) Santa Elena Clinic (Málaga), Old

People's Home (Fuente de Piedra), Rincón Clinic (Béjar), Old People's Home (Ronda). RESIDENCES Alpe Buildings (Tarragona) .LEISURE CENTRES Xesc Forteza Theater (Palma de Mallorca), School of Music (Cádiz), The Royal Calvary (Seville), Ribadeo Auditorium (Lugo), GAS Natural Headquarters (Rubí). BUSINESS CENTRES AND OFFICES Aerospace Engineering Group (Seville), Banca March (Palma de Mallorca), Health Department

Headquarters of the Andalusia Autonomous Government (Cádiz), Hilaturas Ferre (Alicante), Leti Laboratories (Barcelona), Casa del Libro Book Stores (Barcelona), Prenatal (Almeria), Zara HOME (Valencia), Stradivarius (Gerona, A Coruña), Imegasa Paper and Pulp Mill (Mugardos, A Coruña), Pharmaceutical Cooperative (Santiago Compostela), Wine Cooperative (Cacabelos, Leon).


Inspiration, Innovation, Evolution

SPORTS COMPLEX

SCHOOL OF MUSIC

ESADE

LEISURE CENTRE

PUBLIC BUILDING

UNIVERSITY

Location: Andorra Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 600 kW

Location: Mallorca Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 200 kW

Location: Barcelona Initial situation: Renovation Units installed: Kem Modular Digital Scroll Capacity: 195 kW

VOLKSWAGEN

ANDALUCIA PRINCESS

ZARA

BUSINESS CENTRE

HOTEL

COMMERCIAL BUILDING

Location: Barcelona Initial situation: Replacement Units installed: Nexus Capacity: 200 kW

Location: Malaga Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 700 kW

Location: Girona Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 195 kW

MATUTES - FIESTA HOTELS

GRAND PALLADIUM

MUSEUM OF ENTHNOGRAPHY

HOTEL

HOTEL

CULTURAL CENTRE

Location: Ibiza Initial situation: Renovation Units installed: Nexus Capacity: 200 kW

Location: Ibiza Initial situation: Renovation Units installed: Minichillers Capacity: 251 kW

Location: Zamora Initial situation: New construction Units installed: Nexus Capacity: 95 kW

CORDEX TEXTILE COMPANY

NEXUS CHILLERS

BIÈRE ARTISANALE SARLAT BREWERY

Location: Vezac y Sarlat la Caneda (France) Initial situation: Renovation Units installed: Digital Scroll Capacity: 95 kW

Location: Esmoriz (Portugal). Initial situation: New construction Units installed: KEM200HN3 + KEM130HN3 Capacity: 315 kW

311


FANCOILS WATER TERMINAL UNITS PRODUCT RANGE

INTRODUCTION TO THE PRODUCT RANGE......................................314 UNITS HIGH WALL .................................................KFC-AY.....................318 CEILING & FLOOR ........................................KFC-S(E)...................320 CASSETTES 600x600 .................................KFC-CI.......................322 CASSETTES .................................................KFC-CIS.....................324 DUCTS ..........................................................KFC-PD......................326 HIGH PRESSURE DUCTS ............................KFC-PDH...................328 KEY INSTALLATIONS..........................................................................330


FANCOILS FANCOILS FANCOILS

WATER TERMINAL UNITS PRODUCT RANGE


WATER TERMINAL UNITS PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

FANCOILS

WATER TERMINAL UNITS RANGE

Introducing KAYSUN Fan Coils range, a series of water terminal units that include DC inverter fans in practically all its range. These units are the perfect complement to the Nexus range of water chillers. The indoor units of this range have different type of models, such as wall-mounted, ceiling & floor, cassette 600x600, cassette 840x840, ducts and high static pressure ducts. KAYSUN has a perfect solution for every need.

“THE COMFORT OF WATER”

INDOOR UNITS AVAILABLE WITH 2 AND 4 PIPES The Cassette 600x600 and Cassette 840x840 units and low profile duct unit are available with 2 and 4 pipes configurations. The four-pipes configurations allow units to work in Cooling mode and in Heating mode simultaneously and separately in the same installation. Four-pipes coils are fitted with two rows to work in Cooling mode, and with one row to work in Heating mode. The Duct and Cassette units include a standard extended drain pan. The Fancoil Cassette and Duct type units have an optional L-shaped pipework kit for easy installation.

CONTROL KAYSUN Fan Coils have a wide range of controls, whether individual wireless, single wired, centralised or gateways for integration into building management systems. Aesthetically and functionally, KAYSUN offers everything from the classic conventional thermostat with sensor, temperature selection wheel and two switches (heat/ off/cold and 3 speeds), to the most advanced tactile controls.

THERMOSTAT

ADVANCED CONTROL

All KAYSUN Fan Coils are compatible with these controls as standard, except for Duct Fan Coils and Ceiling & Floor Fan Coils, which have basic controls and an interface (with their 2 or 4-tube version) to be managed by the most advanced controls. INTERFACE TO CONTROL

314


Inspiration, Innovation, Evolution

POWER RANGE HIGH WALL 2 PIPES

(Page 318) 490

680

980

KFC-AY-2T-250D

KFC-AY-2T-400D

KFC-AY-2T-600D

FLOW RATE (m3/h)

CEILING & FLOOR 2 PIPES

(Page 320)

370

600

750

1500

KFC-S-2T-250D

KFC-S-2T-400D

KFC-S-2T-500D

KFC-S-2T-900D

KFC-SE-2T-400D

KFC-SE-2T-500D

KFC-SE-2T-900D

FLOW RATE (m3/h)

EXPOSED

CONCEALED KFC-SE-2T-250D

CASSETTES 600x600

(Page 322)

FLOW RATE (m /h) 3

540

780

KFC-CI-2T-300D

KFC-CI-2T-500D

KFC-CI-4T-300D

KFC-CI-4T-500D

2 PIPES

4 PIPES

CASSETTES

(Page 324) 1175

FLOW RATE (m3/h)

1230

1530

1580

1870

2 PIPES KFC-CIS-2T-600D

KFC-CIS-2T-750D

KFC-CIS-2T-950D

KFC-CIS-2T-1200D

KFC-CIS-2T-1500D

4 PIPES KFC-CIS-4T-600D

DUCTS

KFC-CIS-4T-950D

KFC-CIS-4T-1500D

(Page 326) 340

600

730

1020

1450

KFC-PD-2T-200-1

KFC-PD-2T-300D

KFC-PD-2T-400D

KFC-PD-2T-600D

KFC-PD-2T-800D

340

510

680

1020

1360

KFC-PD-4T-200-1

KFC-PD-4T-300-1

KFC-PD-4T-400-1

KFC-PD-4T-600-1

KFC-PD-4T-800-1

FLOW RATE (m3/h)

2 PIPES

FLOW RATE (m3/h)

4 PIPES

FLOW RATE (m3/h)

1700

(Page 328)

2000

KFC-PDH-2T-1000

2380

KFC-PDH-2T-1400

2550

3060

3740

KFC-PDH-2T-1800

KFC-PDH-2T-2200 FANCOILS FANCOILS

HIGH STATIC PRESSURE DUCTS 2 PIPES

Kaysun Fan Coils range will soon be granted with the Eurovent Certification.

315


WATER TERMINAL UNITS PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS

316


Inspiration, Innovation, Evolution

UNITS

FANCOILS FANCOILS

TECHNICAL SPECIFICATIONS

317


WATER TERMINAL UNITS PRODUCT RANGE WALL-MOUNTED

WALL-MOUNTED TECHNICAL SPECIFICATIONS 2 PIPES KFC-AY-2T-250D

KFC-AY-2T-400D

KFC-AY-2T-600D

kW

2.59 (2.39 - 2.7)

3.3 (2.88 - 3.81)

4.26 (3.79 - 4.87)

Kcal/h

2230 (2060 - 2323)

2840 (2480 - 3280)

3660 (3260 - 4190)

1.85 (2.03 - 2.15)

2.71(2.31 - 3.18)

3.56 (3.1 - 4.11)

kW

3.03 (2.63-3.29)

4.33 (3.77 - 5.08)

5.57 (4.77 - 6.31)

Kcal/h

2610 (2260 - 2830)

3720 (3240 - 4370)

4790 (4100 - 5430)

W

11 (10 - 13)

22 (15 - 34)

26 (18 - 38)

MODEL Capacity (min.-max.) Total rated cooling

Rated sensitive cooling (min.-max.) Rated heating capacity (min.- max.)

Power consumption

Rated cooling (min.-max.)

W

10 (8 - 12)

20 (14 - 31)

23 (16 - 33)

m3/h

492/454/400

825/689/590

979/849/717

H

mm

290

290

315

Width

mm

915

915

1072

Depth

mm

230

230

230

Kg

12.7

12.7

14.9

Sound pressure (low/medium/high)

dB (A)

27/30/32

35/39/45

35/40/44

Hydraulic connections Ø

Inches

Rated heating (min.-max.)

Air flow (high/medium/low) Unit dimensions N.W. of the unit

Evaporator pressure drop

Rated cooling (min. - max.)

kPa

28.63 (25.36 - 31.61)

41.23 (33.02 - 56.75)

39.47 (33.66 - 50.68)

Rated heating (min. - max.)

kPa

30.25 (26.53 - 37.49)

37.88 (30.34 - 61.94)

36.3 (30.3 - 51.65)

m3/h

0.46 (0.42 - 0.48)

0.57 (0.51 - 0.67)

0.72 (0.65 - 0.85)

Rated eater flow (min. - max.) Power supply

V/ph/Hz

*Calculation conditions: Cooling: Water inlet/outlet temperature 7/12ºC; Indoor temperature 27ºC dry bulb, 19ºC wet bulb; Fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

318

3/4

220-240/1/50


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS Wall-mounted units with a compact and elegant design. They include a translucent LED display that provides it with a modern design by using the most advanced technology in the market.

2 Pipes.

Standard 3-way on/off valve included.

DC Inverter fan motor

+

COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE.

+

DC INVERTER FAN

KID-02 S *Recommended Kaysun controller.

COMPATIBLE CONTROLLERS

KID-02 S KI-02.3 S

INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR

CENTRALISED KCCT-64 I (B) KCC-64 WEB

MANAGEMENT SYSTEM

BMS INTEGRATION SYSTEMS

KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET

WIFI CONTROL K01-WIFI

FANCOILS FANCOILS

INDIVIDUAL WIRELESS

For further information, please see our Controllers range.

319


WATER TERMINAL UNITS PRODUCT RANGE FLOOR / CEILING

CEILING & FLOOR TECHNICAL SPECIFICATIONS 2 PIPES EXPOSED MODEL

Rated total cooling

Capacity (min.- max.)

kW Kcal/h

Rated sensitive cooling (min.-max.) Rated heating capacity (min.- max.)

Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit Width dimensions Depth N.W. of the unit Sound pressure (low/medium/high) Hydraulic connections Ø Rated cooling (min. - max.) Evaporator pressure drop Rated heating (min. - max.) Rated eater flow (min. - max.) Power consumption

Power supply

kW Kcal/h W W m3/h mm mm mm Kg dB (A) Inches kPa kPa m3/h V/ph/ Hz

KFC-S-2T-250D

KFC-S-2T-400D

KFC-S-2T-500D

KFC-S-2T-900D

1.52 (1.07 - 2.07) 1310 (920 - 1780) 1.07 (0.72 - 1.52) 2.07 (1.42 - 2.78) 1780 (1220 -2390) 10 (7 - 17) 11 (7 - 18) 369/272/196 592 800 220 24.4 22/31/39

2.63 (2.12 - 3.25) 2260 (1820 - 2790) 1.93 (1.5 - 2.48) 3.34 (2.63 - 4.37) 2870 (2260 - 3760) 16 (10 - 30) 15 (9 - 30) 604/448/343 592 1000 220 28.2 31/37/44

3.73 (2.8 - 4.82) 3200 (2410 - 4140) 2.62 (1.9 - 3.51) 4.65 (3.44 - 6.17) 4000 (2960 - 5310) 16 (10 - 31) 16 (10 - 31) 748/555/398 592 1200 220 34.2 27/35/42

5.67 (4.72 - 7.17) 4875 (4060 - 6170) 4.47 (3.6 - 5.92) 7.48 (5.94 - 9.96) 6430 (5110 - 8560) 38 (21 - 103) 38 (21 - 106) 1509/1054/806 592 1500 220 40 35/42/51

6.7 (3.8 - 11.13) 5.22 (3 - 11.99) 0.27 (0.20 - 0.36)

16.38 (11.14 - 23.2) 13.86 (9.1 - 22.9) 0.49 (0.38 - 0.59)

17.1 (10.74 - 27.32) 14.1 (9 - 27.46) 0.65 (0.51 - 0.85)

18.96 (14.04 - 30.94) 16.71 (12.38 - 34.9) 0.99 (0.84 - 1.29)

3/4

220-240/1/50

2 PIPES CONCEALED MODEL

Rated total cooling

Capacity (min.- max.) Rated sensitive cooling (min.-max.) Rated heating capacity (min.- max.)

Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit Width dimensions Depth N.W. of the unit Sound pressure (low/medium/high) Hydraulic connections Ø Rated cooling (min. - max.) Evaporator pressure drop Rated heating (min. - max.) Rated eater flow (min. - max.) Power consumption

Power supply

kW Kcal/h kW Kcal/h W W m3/h mm mm mm Kg dB (A) Inches kPa kPa m3/h V/ph/ Hz

KFC-SE-2T-250D

KFC-SE-2T-400D

KFC-SE-2T-500D

KFC-SE-2T-900D

1.52 (1.07 - 2.07) 1310 (920 - 1780) 1.07 (0.72 - 1.52) 2.07 (1.42 - 2.78) 1780 (1220 -2390) 10 (7 - 17) 11 (7 - 18) 369/272/196 545 550 212 17 22/31/39

2.63 (2.12 - 3.25) 2260 (1820 - 2790) 1.93 (1.5 - 2.48) 3.34 (2.63 - 4.37) 2870 (2260 - 3760) 16 (10 - 30) 15 (9 - 30) 604/448/343 545 750 212 20 31/37/44

3.73 (2.8 - 4.82) 3200 (2410 - 4140) 2.62 (1.9 - 3.51) 4.65 (3.44 - 6.17) 4000 (2960 - 5310) 16 (10 - 31) 16 (10 - 31) 748/555/398 545 950 212 25 27/35/42

5.67 (4.72 - 7.17) 4875 (4060 - 6170) 4.47 (3.6 - 5.92) 7.48 (5.94 - 9.96) 6430 (5110 - 8560) 38 (21 - 103) 38 (21 - 106) 1509/1054/806 545 1250 212 32 35/42/51

6.7 (3.8 - 11.13) 5.22 (3 - 11.99) 0.27 (0.20 - 0.36)

16.38 (11.14 - 23.2) 13.86 (9.1 - 22.9) 0.49 (0.38 - 0.49)

17.1 (10.74 - 27.32) 14.1 (9 - 27.46) 0.65 (0.51 - 0.85)

18.96 (14.04 - 30.94) 16.71 (12.38 - 34.9) 0.99 (0.84 - 1.29)

3/4

*Calculation conditions: Cooling: Water inlet/outlet temperature 7/12ºC; Indoor temperature 27ºC dry bulb, 19ºC wet bulb; Fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

320

220-240/1/50


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS This unit is especially designed to save space. Due to its reduced depth, it is the perfect solution that adapts to every type of installation, from wall-mounted to floor standing, whether totally or partially recessed, adapting perfectly to the aesthetics of the environment.

2 pipes

DC Inverter fan motor

*It can be integrated in the body of the concealed FLOOR / CEILING type units

+

DC INVERTER FAN

+

HORIZONTAL/VERTICAL INSTALLATION

COMPATIBLE WITH

, Thermostat KC-FC-2T

or Thermostat KC-FCD-2T

+

COMPATIBLE WITH

Interface to control

Thermostat KC-FCS-2T

CHOOSE YOUR

CONTROLLER

CONTROLLERS COMPATIBLE WITH THE INTERFACE TO KAYSUN CONTROLLER INDIVIDUAL WIRELESS

INDIVIDUAL WIRED

KID-02 S KI-02.3 S

KC-01 S KC-02.1 H KCT-02.1 SR

CENTRALISED KCCT-64 I (B) KCC-64 WEB

MANAGEMENT SYSTEM

BMS INTEGRATION SYSTEMS

KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET

WIFI CONTROL K01-WIFI

For further information, please see our Controllers range.

COMPATIBLE ACCESSORIES

IT INCLUDES:

IT INCLUDES:

• 3 BUTTONS

KC-FC-2T

KC-FCD-2T

ON/OFF HOT/COLD 3 SPEEDS

• DIRECTIONAL BUTTONS FOR INCREASING/ REDUCING TEMPERATURE • TIMER

• 3 BUTTONS

KC-FCS-2T *Kaysun thermostat recommended for concealed units

ON/OFF HOT/COLD 3 SPEEDS

• DIRECTIONAL BUTTONS FOR INCREASING/ REDUCING TEMPERATURE

K01-FC-2T

KV3-FC 3/4

KACT-0

ACCESSORIES DESCRIPTION

MODEL

DESCRIPTION

Pipework kit for CEILING & FLOOR 2T valve

K01-FC-2T

KAYSUN control interface

KC-FC-2T

Thermostat 2T

KV3-FC 3/4

3-way valve 3/4

KC-FCD-2T

Thermostat with display

KACT-O

On/off actuator

KC-FCS-2T

Thermostat with display (recommended for CONCEALED ducts)

FANCOILS FANCOILS

MODEL KIT TUB FC S(E)2T-1

321


WATER TERMINAL UNITS PRODUCT RANGE CASSETTES

CASSETTES 600x600 TECHNICAL SPECIFICATIONS 2 PIPES MODEL Capacity (min.-max.) Rated total cooling

kW Kcal/h

Rated sensitive cooling (min.-max.) Rated heating (min.-max.)

Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit dimensions Width Depth N.W. of the unit H Panel dimensions Width Depth Panel net weight Sound pressure (low/medium/high) Hydraulic connections Ø Evaporator pressure Rated cooling (min. - max.) drop Rated heating (min. - max.) Rated eater flow (min. - max.) Power supply Power consumption

kW Kcal/h W W m3/h mm mm mm Kg mm mm mm Kg dB (A) Inches kPa kPa m3/h V/ph/Hz

KFC-CI-2T-300D

KFC-CI-2T-500D

2.53 (2 - 2.98) 2180 (1720 - 2560) 2.08 (1.59 - 2.49) 3.35 (2.61 - 4.01) 2880 (2240 - 3450) 9 (5 - 15) 9 (5 - 14) 535/429/322 261 575 575 16.5 50 647 647 2.5 27/33/39

3.48 (3.01 - 4.2) 2990 (2590 - 3610) 2.74 (2.31 - 3.45) 4.69 (3.84 - 5.76) 4030 (3300 - 4950) 28 (21 - 43) 18 (11 - 23) 781/611/494 261 575 575 16.5 50 647 647 2.5 32/38/43

3/4

7 (5 - 10) 6 (3.8 - 8.2) 0.45 (0.35 - 0.53)

8.62 (7.4 - 12.32) 6.5 (5.41 - 11.41) 0.61 (0.54 - 0.75) 220-240/1/50

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

4 PIPES MODEL Capacity (min.-max.) Rated total cooling

Rated sensitive cooling (min.-max.) Rated heating (min.-max.)

Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit dimensions Width Depth N.W. of the unit H Panel dimensions Width Depth Panel net weight Sound pressure (low/medium/high) Cooling operation Hydraulic connections Ø Heating Evaporator pressure Rated cooling (min. - max.) drop Rated heating (min. - max.) Cooling operation Rated eater flow (min. - max.) Heating Power supply Power consumption

kW Kcal/h kW Kcal/h W W m3/h mm mm mm Kg mm mm mm Kg dB (A) Inches Inches kPa kPa m3/h m3/h V/ph/Hz

KFC-CI-4T-300D

KFC-CI-4T-500D

2.08 (1.65 - 2.4) 1790 (1420 - 2060) 1.78 (1.39 - 2.08) 3.25 (2.55 - 3.85) 2790 (2190 - 3310) 9 (5 - 14) 9 (5 - 15) 536/429/321 261 575 575 16.7 50 647 647 2.5 27/33/39

2.62 (2.3 - 3.05) 2250 (1980 - 2620) 2.21 (1.9 - 2.61) 4.12 (3.5 - 4.9) 3540 (3010 - 4210) 17 (11 - 32) 17 (10 - 32) 731/572/462 261 575 575 16.7 50 647 647 2.5 31/39/44

13.5 (9.3 - 17.4) 21.7 (14.3 - 29.8) 0.36 (0.29 - 0.42) 0.36/0.30/0.24

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

322

3/4 1/2

220-240/1/50

13.1 (10.3 - 16.8) 25.9 (19 - 36.1) 0.47 (0.40 - 0.54) 0.46/0.38/0.33


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS With its new 360º panel, the Art Flux cassette provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact (570mm width and depth), they are lighter and require less space and equipment to be installed. They can be completely integrated into any space, including shallow ceilings, without sticking out.

Fresh air supply and air blow towards adjacent rooms.

Standard extended drainage pan.

Optional pipework kit.

Optional three-way valve.

Optional on/off valve driver.

DC Inverter fan motor.

Condensation pump.

+

DC INVERTER FAN

+

SAME PANEL AS VRF - ART FLUX 360º UNITS

CASSETTE 600x600 2 PIPES

KID-02 S *Kaysun controller recommended

CASSETTE 600x600 4 PIPES

COMPATIBLE CONTROLLERS INDIVIDUAL WIRELESS KID-02 S KI-02.3 S

INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR

CENTRALISED KCCT-64 I (B) KCC-64 WEB

MANAGEMENT SYSTEM

BMS INTEGRATION SYSTEMS

KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET

WIFI CONTROL K01-WIFI

For further information, please see our Controllers range.

COMPATIBLE ACCESSORIES 2 PIPES

KIT TUB FC CI-2T

KV3-FC 3/4

COMPATIBLE ACCESSORIES 4 PIPES

KACT-0

TUB FC CI-4T KIT

KV3-FC 1/2

KACT-0

KV3-FC 3/4

ACCESSORIES FOR 2 PIPES UNITS DESCRIPTION

MODEL

DESCRIPTION

KIT TUB FC CI-2T

Pipework kit for Cassette 600x600 units’ valve

TUB FC CI-4T KIT

Pipework kit for Cassette 600x600 units' valve

KV3-FC 3/4

3-way valve 3/4

KV3-FC 1/2

3-way valve 1/2 (hot water)

KACT-O

on/off Actuator

KV3-FC 3/4

3-way valve 3/4 (cool water)

KACT-O*

on/off Actuator

FANCOILS FANCOILS

MODEL

ACCESSORIES FOR 4 PIPES UNITS

*You will need 2 actuators for your 4-Ducts Fan Coil.

323


WATER TERMINAL UNITS PRODUCT RANGE CASSETTES

CASSETTES TECHNICAL SPECIFICATIONS 2 PIPES KFC-CIS-2T-600D KFC-CIS-2T-750D KFC-CIS-2T-950D KFC-CIS-2T-1200DKFC-CIS-2T-1500D

MODEL

kW 5.3 (4.4 - 5.93) 5.45 (4.6 - 6.12) 6.84 (6.35 - 7.84) 7.12 (6.67 - 7.87) 8.82 (7.48 - 11.19) Capacity (min.- max.) Kcal/h 4560 (3780 - 5100) 4690 (3960 - 5260) 5880 (5460 - 6740) 6120 (5740 - 6770) 7580 (6430 - 9620) Rated total Rated sensitive cooling (min.-max.) 4.34 (3.52 - 5) 4.51 (3.72 - 5.18) 5.6 (5.13 - 6.63) 5.95 (5.5 - 6.68) 7.03 (5.97 - 9.04) cooling kW 7.37 (6.06 - 8.42) 7.49 (6.27 - 8.62) 9.24 (8.49 - 10.86) 9.84 (9.16 - 10.92) 11.73 (10.07 - 14.92) Rated heating (min.-max.) Kcal/h 6340 (5210 - 7240) 6440 (5390 - 7410) 7950 (7300 - 9340) 8460 (7880 - 9390) 10090 (8660 - 12830) Rated cooling (min.-max.) W 27 (17 - 41) 31 (20 - 49) 42 (34 - 75) 59 (45 - 85) 58 (39 - 126) Power consumption Rated heating (min.-max.) W 28 (17 - 42) 31 (19 - 49) 42 (33 - 76) 58 (45 - 85) 58 (39 - 127) Air flow (high/medium/low) m3/h 1175/987/768 1229/1020/810 1530/1224/1101 1581/1371/1236 1871/1415/1198 H mm 230 230 300 300 300 Unit Width mm 840 840 840 840 840 dimensions Depth mm 840 840 840 840 840 N.W. of the unit Kg 23 23 27 27 29.5 H mm 45 45 45 45 45 Panel Width mm 950 950 950 950 950 dimensions Depth mm 950 950 950 950 950 Panel net weight Kg 6 6 6 6 6 Sound pressure (low/medium/high) dB (A) 33/39/43 34/40/44 39/42/46 41/44/48 39/43/49 Hydraulic connections Ø Inches 3/4 Rated cooling (min. - max.) kPa 15.4 (11 - 19.2) 17.4 (12.4 - 21.3) 17 (14.1 - 22) 18.1 (16.3 - 22.3) 22.7 (16.4 - 36.6) Evaporator pressure drop Rated heating (min. - max.) kPa 12.7 (8.6 - 16.9) 14.8 (10.6 - 19.1) 15.2 (12.6 - 19.9) 16.2 (14.7 - 20) 21.3 (15 - 34.3) Rated eater flow (min. - max.) 0.92 (0.77 - 1.05) 0.96 (0.81 - 1.10) 1.24 (1.13 - 1.43) 1.28 (1.22 - 1.44) 1.53 (1.28 - 1.96) m3/h Power supply V/ph/Hz 220-240/1/50 *Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

4 PIPES MODEL Capacity (min.-max.) Rated total cooling

Rated sensitive cooling (min.-max.) Rated heating (min.-max.)

Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit dimensions Width Depth N.W. of the unit H Panel dimensions Width Depth Panel net weight Sound pressure (low/medium/high) Cooling operation Hydraulic connections Ø Heating Evaporator pressure Rated cooling (min. - max.) drop Rated heating (min. - max.) Cooling operation Rated eater flow (min. - max.) Heating Power supply Power consumption

kW Kcal/h kW Kcal/h W W m3/h mm mm mm Kg mm mm mm Kg dB (A) Inches Inches kPa kPa m3/h m3/h V/ph/Hz

KFC-CIS-4T-600D

KFC-CIS-4T-950D

KFC-CIS-4T-1500D

4.81 (4 - 5.36) 4140 (3440 - 4610) 4.17 (3.42 - 4.66) 6.88 (5.83 - 7.66) 5920 (5010 - 6590) 33 (19 - 50) 33 (19 - 50) 1287/1084/851 300 840 840 27.5 45 950 950 6 31/37/42

5.07 (4.75 -5.82) 4360 (4080 - 5000) 4.45 (4.14 - 5.18) 7.24 (6.76 - 8.37) 6230 (5810 - 7200) 42 (32 - 77) 41 (32 - 76) 1525/1212/1088 300 840 840 27.5 45 950 950 6 38/41/46 3/4 1/2 12.6 (10.9 - 16.4) 33.5 (29.3 - 43.8) 0.9 (0.83 - 1.04) 0.67 (0.63 - 0.78) 220-240/1/50

7.29 (6.45 - 8.76) 6270 (5550 - 7530) 6.2 (5.4 - 7.7) 10.53 (9.53 - 12.47) 9050 (8190 - 10720) 58 (38 - 125) 58 (38 - 126) 1857/1410/1191 300 840 840 30 45 950 950 6 38/43/49

11.5 (8.1 - 14.8) 26.1 (19.3 - 37.2) 0.87 (0.72 - 0.99) 0.62 (0.54 - 0.69)

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

324

22.6 (17.7 - 33) 45.7 (38.3 - 62.1) 1.30 (1.15 - 1.58) 0.96 (0.87 - 1.14)


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS The360º panel Art Flux Cassette unit provides an even, fast airconditioning controller that is far-reaching with no dead zones due to its additional motor, which allows the louvres to swing between 37 and 42º. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out.

DC INVERTER FAN

• • • • • • •

Condensation pump. Fresh air supply and air blow towards adjacent rooms. Standard extended drainage pan. Optional pipework kit. Optional three-way valve. Optional ON/OFF valve driver. DC Inverter fan motor.

+ +

SAME PANEL AS VRF - ART FLUX 360º UNITS

KID-02 S *Kaysun controller recommended

CASSETTE 2 PIPES

CASSETTE 4 PIPES

COMPATIBLE CONTROLLERS INDIVIDUAL WIRELESS KID-02 S KI-02.3 S

INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR

CENTRALISED KCCT-64 I (B) KCC-64 WEB

MANAGEMENT SYSTEM

BMS INTEGRATION SYSTEMS

KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET

WIFI CONTROL K01-WIFI

For further information, please see our Controllers range.

KIT TUB FC CIS-2T

KV3-FC 3/4

COMPATIBLE ACCESSORIES 4 PIPES

KACT-0

ACCESSORIES FOR 2 PIPES UNITS

KIT TUB FC CIS-4T

KV3-FC 1/2 KV3-FC 3/4

KACT-0

ACCESSORIES FOR 4 PIPES UNITS

MODEL

DESCRIPTION

MODEL

DESCRIPTION

KIT TUB FC CIS-2T

Pipework kit for valve Cassette unit with 2 pipes

KIT TUB FC CIS-4T Pipework kit for 4-pipes Cassette model valves

KV3-FC 3/4

3-way valve 3/4

KACT-O

on/off Actuator

KV3-FC 1/2

3-way valve 1/2 (hot water)

KV3-FC 3/4

3-way valve 3/4 (cool water)

KACT-O*

on/off Actuator

FANCOILS FANCOILS

COMPATIBLE ACCESSORIES 2 PIPES

*You will need 2 actuators for your 4-Ducts Fan Coil.

325


WATER TERMINAL UNITS PRODUCT RANGE DUCTS

Ducts TECHNICAL SPECIFICATIONS 2 PIPES MODEL

DC

DC

DC

DC

KFC-PD-2T-200-1 KFC-PD-2T-300D KFC-PD-2T-400D KFC-PD-2T-600D KFC-PD-2T-800D

kW 1.91 (1.68 - 2.2) 2.72 (2.1 - 3.12) 3.26 (2.5 - 3.99) 4.82 (3.78 - 5.85) 6.36 (5.08 - 8.02) Capacity (min.- max.) Kcal/h 1700 (1450 - 1890) 2340 (1810 - 2680) 2800 (2150 - 3430) 4140 (3250 - 5030) 5470 (4370 - 6900) Rated total Rated sensitive cooling (min.-max.) 1.35 (1.15 - 1.52) 2 (1.49 - 2.53) 2.44 (1.8 - 3.1) 3.58 (2.7 - 4.49) 4.74 (3.64 - 6.19) cooling kW 3.08 (2.59 - 3.5) 3.61 (2.71 - 4.51) 4.55 (3.27 - 5.52) 6.35 (4.81 - 7.84) 8.46 (6.68 - 10.88) Rated heating (min.-max.) Kcal/h 2650 (2230 - 3010) 3100 (2330 - 3880) 3910 (2810 - 4750) 5460 (4140 - 6740) 7270 (5740 - 9360) Rated cooling (min.-max.) W 33 (22 - 49) 12 (7 - 20) 15 (9 - 26) 24 (12 - 49) 28 (16 - 60) Power consumption Rated heating (min.-max.) W 33 (22 - 49) 13 (8 - 23) 16 (9 - 28) 25 (13 - 52) 30 (17 - 65) Static pressure available (high/medium/low) Pa 12/30/50 Air flow (high/medium/low) m3/h 340/255/170 596/442/311 734/564/389 1022/760/544 1452/1038/781 H mm 241 241 241 241 241 Unit Width mm 741 841 941 1161 1461 dimensions Depth mm 222 522 522 522 522 N.W. of the unit Kg 14.6 19 21 23.7 33 Sound pressure (low/medium/high) dB (A) 26/32/35 37/44/50 38/45/52 42/49/57 42/49/58 Hydraulic connections Ø Inches 3/4 Rated cooling (min. - max.) kPa 8.9 (6.7 - 14) 16.4 (11.3 - 23.8) 9.3 (5.8 - 13) 22 (14.2 - 31.4) 20.5 (13.9 - 31.6) Evaporator pressure drop Rated heating (min. - max.) kPa 6.2 (4.4 - 10.5) 12.9 (8.5 - 19.2) 7.7 (4.8 - 10.8) 18.2 (11.4 - 26.4) 16.9 (11.5 - 26.3) Rated eater flow (min. - max.) 0.48 (0.37 - 0.6) 0.57 (0.43 - 0.69) 0.85 (0.65 - 1.05) 1.11 (0.89 - 1.42) m3/h 1.11 (0.89 - 1.42) Power supply V/ph/Hz 220-240/1/50 *Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

4 PIPES MODEL

KFC-PD-4T-200-1 KFC-PD-4T-300-1 KFC-PD-4T-400-1 KFC-PD-4T-600-1 KFC-PD-4T-800-1

kW Capacity (min.- max.) Kcal/h Rated total Rated sensitive cooling (min.-max.) cooling kW Rated heating (min.-max.) Kcal/h Rated cooling (min.-max.) W Power consumption Rated heating (min.-max.) W Static pressure available (high/medium/low) Pa Air flow (high/medium/low) m3/h H mm Unit Width mm dimensions Depth mm N.W. of the unit Kg Sound pressure (low/medium/high) dB (A) Cooling operation Inches Hydraulic connections Ø Heating Inches Rated cooling (min. - max.) kPa Evaporator pressure drop Rated heating (min. - max.) kPa Rated eater Cooling operation m3/h flow (min. Heating m3/h max.) Power supply V/ph/Hz

1.76 (1.52 - 2) 2.35 (2.13 - 2.7) 3.15 (2.76 - 3.6) 1510 (1310 - 1720) 2020 (1830 - 2320) 2710 (2370 - 3100) 1.29 (1.1 - 1.38) 1.43 (1.27 - 1.86) 1.97 (1.57 - 2.48) 2.64 (2.22 - 3) 3.48 (3 - 4) 4.47 (3.9 - 5.2) 2270 (1910 - 2580) 2990 (2580 - 3440) 3840 (3350 - 4470) 33 (22 - 49) 53 (32 - 64) 66 (19 - 75) 33 (22 - 49) 53 (32 - 64) 66 (19 - 75) 12/30/50 340/255/170 510/385/255 680/510/340 241 241 241 741 841 941 522 522 522 15.1 17.5 20.7 26/32/35 27/33/36 28/34/37 3/4 3/4 4.8 (3.5 - 7.6) 9.67 (6.84 - 14.4) 5.85 (3.64 - 8.2) 4 (2.75 - 6.8) 8.39 (5.54 - 12.5) 16.75 (10.44 - 23.5) 0.24 (0.20 - 0.34) 0.46 (0.28 - 0.46) 0.52 (0.39 - 0.62) 0.18 (0.15 0.26)

1020/765/510 241 1161 522 23.5 30/36/40

1360/1020/680 241 1461 550 32.4 33/39/43

12.1 (7.76 - 17.2) 12.19 (8.27 - 18.8) 29 (17.56 - 40.7) 13.29 (9.1 - 20.7) 0.72 (0.54 - 0.86) 0.91 (0.73 - 1.17)

0.28 (0.20 - 0.34) 0.38 (0.29 - 0.45) 0.52 (0.40 - 0.62) 0.64 (0.52 - 0.83) 220-240/1/50

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

326

4.32 (3.84 - 5) 5.78 (5.11 - 6.8) 3710 (3300 - 4300) 4970 (4390 - 5850) 3.29 (2.34 - 3.99) 3.86 (2.73 - 4.68) 6.19 (5.33 - 7.2) 8.45 (7.2 - 9.6) 5320 (4580 - 6190) 7270 (6190 - 8250) 100 (57 - 114) 145 (72.5 - 154) 100 (57 - 114) 145 (72.5 - 154)


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS • • • • • • • •

The duct type units include a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms where ceilings are just 241 mm high. Similar characteristics to direct expansion ducts, except that it does not have a condensate pump. • • •

Plate to support duct during suction/discharge. 3 pipe rows. DC Inverter Fan (depending to the model).

Removable filter without opening the duct unit case. Replaceable outlet panel (rear/lower). Fresh air supply. Available pressure 12/30/50 Pa Standard extended drainage pan on the left-hand side. Optional left/right pipework kit. Optional three-way valve. Optional on/off valve driver.

COMPATIBLE WITH

Compatible with

Thermostat KC-FC-2T (2 Ducts) KC-FC-4T (4 Ducts)

Compatible with

DUCT 2 PIPES

DUCT 4 PIPES

Interface to control

COMPATIBLE WITH

Thermostat KC-FCD-2T (2 Ducts)

+ CONTROLLER CHOOSE YOUR

CONTROLLERS COMPATIBLE WITH THE INTERFACE TO KAYSUN CONTROLLER INDIVIDUAL WIRELESS KID-02 S KI-02.3 S

INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR

CENTRALISED KCCT-64 I (B) KCC-64 WEB

MANAGEMENT SYSTEM

BMS INTEGRATION SYSTEMS

KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

WIFI CONTROL

K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET

K01-WIFI

For further information, please see our Controllers range.

COMPATIBLE ACCESSORIES 2 PIPES

COMPATIBLE ACCESSORIES 4 PIPES

IT INCLUDES: • 3 BUTTONS

K01-FC-2T

KIT TUB FC PD-2T-1

KV3-FC 3/4 KACT-0

KC-FC-2T KC-FCD-2T

ON/OFF HOT/COLD 3 SPEEDS

K01-FC-4T

KIT TUB FC PD-4T-1

KV3-FC 3/4 KACT-0 KC-FC-4T

• DIRECTIONAL BUTTONS FOR INCREASING/ REDUCING TEMPERATURE • TIMER

ACCESSORIES FOR 4 PIPES UNITS

MODEL

DESCRIPTION

MODEL

DESCRIPTION

KIT TUB FC PD-2T-1

Plumbing kit for 2-pipes low profile pipes valves

KIT TUB FC PD-4T-1

Plumbing kit for 4-pipes low profile pipes valves

KV3-FC 3/4

3-way valve 3/4

KV3-FC 3/4

3-way valve 3/4

KACT-O

on/off Actuator

KACT-O*

on/off Actuator

K01-FC-2T

Interface to KAYSUN 2T control

K01-FC-4T

KAYSUN 4T control interface

KC-FC-2T

Thermostat 2 pipes

KC-FC-4T

Thermostat 4 pipes

KC-FCD-2T

2 Ducts thermostat with display

FANCOILS FANCOILS

ACCESSORIES FOR 2 PIPES UNITS

*You will need 2 valves and 2 actuators for your 4-Ducts Fan Coil.

327


WATER TERMINAL UNITS PRODUCT RANGE DUCTS

HIGH PRESSURE DUCTS 2 PIPES TECHNICAL SPECIFICATIONS 2 PIPES MODEL kW Capacity (high) Kcal/h Rated total Rated sensitive cooling capacity (high) cooling kW Rated heating capacity (high) Kcal/h Power consumption W Static pressure available (high/medium/low) Pa Air flow (high/medium/low) m³/h H mm Unit Width mm dimensions Depth mm N.W. of the unit Kg Sound pressure (low/medium/high) dB (A) Hydraulic connections Ø Inches Rated cooling (min. - max.) kPa Evaporator pressure drop Rated heating (min. - max.) kPa Rated eater flow (min. - max.) m³/h Power supply V/ph/Hz

KFC-PDH-2T-1000

KFC-PDH-2T-1400

KFC-PDH-2T-1800

KFC-PDH-2T-2200

8.8 7570 6.06 13.2 11350 350 70 1700/1530/1380 400 946 816 52 36/43/50

12 10320 8.26 17.9 15390 350 70 2380/2120/1860 400 946 816 54 38/45/52

15.8 13590 10.88 23.8 20460 800 100 3060/2750/2450 400 1290 809 76 46/53/60

19.9 17110 13.7 30 25800 950 100 3740/3360/2990 400 1290 809 76 47/54/61

24 25 1.51

36 34.2 2.06

90 85 2.72

130 121 3.42

3/4

220-240/1/50

*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.

328


Inspiration, Innovation, Evolution

GENERAL CHARACTERISTICS With the help of these ducts, the indoor unit is able to reach up to 100pa (1800 and 2200 models). This results in flexible ducts that make air-conditioning easier, more accurate and adaptable to every space, even in high ceilings rooms.

2 Pipes.

Flanges in suctions/discharge for duct fitting.

COMPATIBLE WITH

Thermostat KC-FC-2T

Compatible with

Thermostat KC-FCD-2T

+

Compatible with

CHOOSE YOUR

Interface to control

COMPATIBLE WITH

CONTROLLER

1800 - 2200 MODELS

1000 - 1400 MODELS

CONTROLLERS COMPATIBLE WITH THE INTERFACE TO KAYSUN CONTROLLER INDIVIDUAL WIRELESS

INDIVIDUAL WIRED

KID-02 S KI-02.3 S

MANAGEMENT SYSTEM

CENTRALISED

KC-01 S KC-02.1 H KCT-02.1 SR

KCCT-64 I (B) KCC-64 WEB

BMS INTEGRATION SYSTEMS

KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32

K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET

WIFI CONTROL K01-WIFI

For further information, please see our Controllers range.

COMPATIBLE ACCESSORIES

IT INCLUDES: • 3 BUTTONS

KACT-0

K01-FC-2T

KC-FC-2T

KC-FCD-2T

ACCESSORIES.

• DIRECTIONAL BUTTONS FOR INCREASING/REDUCING TEMPERATURE • TIMER

MODEL

DESCRIPTION

KIT TUB FC PDH-2T

Pipework kit for valve High Static Pressure Ducts

KIT TUB FC PDH-2T-1400

Pipework kit for valve High Static Pressure Ducts (model 1400)

KV3-FC 3/4

3-way valve 3/4

KACT-O

on/off Actuator

K01-FC-2T

Interface to KAYSUN 2T control

KC-FC-2T

Thermostat 2 pipes

KC-FCD-2T

2 Ducts thermostat with display

FANCOILS FANCOILS

KV3-FC 3/4

ON/OFF HOT/COLD 3 SPEEDS

329


WATER TERMINAL UNITS PRODUCT RANGE KEY INSTALLATIONS

REFERENCES KEY INSTALLATIONS

TEA SHOP OFFICES BUSINESS CENTRE Location: Barcelona Initial situation: Renovation Units installed: Cassette 600x600 Capacity: 65 kW

330


FANCOILS FANCOILS

Inspiration, Innovation, Evolution

331


WATER TERMINAL UNITS PRODUCT RANGE KEY INSTALLATIONS

THE INDOOR UNITS OF THE FANCOIL RANGE ARE THE BEST COMPLEMENT FOR THE NEXUS RANGE CHILLERS. THE FANCOILS RANGE INCLUDES A WIDE VARIETY OF MODELS AND CAPACITIES THAT ARE AVAILABLE IN 2 AND 4 PIPES CONFIGURATIONS. THESE HIGHLY VERSATILE UNITS ADAPT TO EVERY TYPE OF INSTALLATION.

SUN BEACH APARTMENTS

Location: Santa Ponça Initial situation: Renovation Units installed: Wall Capacity: 55 kW

OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN FANCOILS BUSINESS CENTRES AND OFFICES Cardomore Water Plant (Ibiza), CIE Galfor (Orense),

332

PUBLIC BUILDINGS “Miguel Rodríguez” Multipurpose Centre for Elderly People Comprehensive Care (Cadiz), Museo de la Cruz Museum (Córdoba)

HOTELS Andreas Apartments (Majorca)


Inspiration, Innovation, Evolution

TEA SHOP OFFICES

SANTO ANGEL SCHOOL

BUSINESS CENTRE

PUBLIC BUILDING

Location: Barcelona Initial situation: Renovation Units installed: Cassette 600x600 Capacity: 65 kW

Location: Madrid Initial situation: Renovation Units installed: different models Capacity: 95 kW

JUAN MARCH HOSPITAL

REGINA PARK HOTEL

PUBLIC BUILDING

HOTEL

Location: Mallorca Initial situation: Renovation Units installed: Cassette 600x600 Capacity: 330 kW

Location: Ibiza Initial situation: Renovation Units installed: different models Capacity: 195 kW

COEPS FIRE BRIGADE HEADQUARTERS

LLOBREGAT WATER PLANT

PUBLIC BUILDING

BUSINESS CENTRE

Location: Barcelona Initial situation: Renovation Units installed: Cassette 840x840 and 600x600 Capacity: 75 kW

FANCOILS FANCOILS

Location: Seville Initial situation: Renovation Units installed: KEM 30 DHN2KH + 6 KFC PD + RITE 4000.2+ Capacity: 30 kW

333


CONDITIONS OF SALE 1.- ORDERS An order is considered to be the receipt of a written document (via mail, Fax or regular mail which includes the description of the materials requested, order reference, delivery time requested, expected place of delivery and any data that may be required for the successful confirmation in the process of accepting the invoice. For telephone orders, delivery of the materials shall be subject to receipt of the written confirmation of the order with the data described above. For orders of materials or specially manufactured equipment not generally available in stock, a deposit of 30% of the total amount of the final price of the equipment will be required as a prerequisite to its manufacture.

2.- ORDER CANCELLATION Only those cancellations will be accepted that have been notified in writing prior to deliver the goods. Under no circumstances may orders be cancelled for materials or equipment that are specially manufactured and not generally in stock. Additional the buyer waives the right to a refund of the 30% of the total amount of the final price of the equipment invoiced prior to its manufacture.

Deliveries of the goods by ourselves cannot be at a specific time of day, such deliveries being for the account of the buyer by any means he deems appropriate. Complaints about the material or equipment delivered with defects arising from the transport shall be made within 24 Hours of receipt. Claims made after this will be exempt.

6.- Returns The buyer may request return of those materials and equipment for reasons beyond his will provided that the packaging and operation are in a perfect condition for approval by Frigicoll SA and subsequent return of the same after written and signed acceptance and return number provided. A written and numbered authorization from Frigicoll is essential for receipt of the goods in our facilities and the costs of carriage for the aforementioned return will always be for the account of the buyer A demerit of 15% of the value of the sale will be applied. If after inspection of the material does not meet these requirements there will be a devaluation from your payment, which may be up to the total original invoice value of your order.

7.- GUARANTEES 3.- PRICES The prices published in the price list include the carriage of material supplied in our warehouses, the warehouses or premises of the buyer or on site by truck throughout the Peninsula. Outside this area, the cost of transport will be charged based on the place of delivery. All the data quoted in this catalogue are subject to change without prior notice, including the possible typographical errors. Prices do not include value-added taxes (VAT), RAE for machines of less than 12kW or any other tax in force and will always will be for the buyer's account.

4.- DELIVERY TIME The buyer shall indicate the delivery time for the materials that he requests. When any of the materials are not available from stock, a forecast delivery date will be provided for guidance and in no case will a failure to meet this be the cause of a claim on the part of the buyer.

The equipment supplied will have a minimum of 2 years garantee against manufacturing defects provided that its installation and use is appropriate, and in no case can faults be attributable to the guarantee that arise from improper installation, abnormal use, inappropriate electrical voltage, faulty maintenance, use of materials not approved by Frigicoll SA, and manipulation by people not approved for this purpose. The guarantee will cover the replacement of parts and components in poor condition by new parts, but in no case the labour required for that purpose.

8.- JURISDICTION The general conditions of sale shall be construed as being accepted by the buyer at time of ordering. In the case of any disagreement that may arise between the parties, these expressly commit themselves to the courts of Barcelona with express waiver of any other jurisdiction that might apply.

9.- SPECIFICATIONS AND IMAGES 5.- DELIVERY CONDITIONS Standard incoterms would be Ex-Works Vilarodona. Other conditions to be agreed individually.

The manufacturer reserves the right to change the specifications and images of the product without prior notice.


Inspiration, Innovation, Evolution


Main Office Blasco de Garay, 4-6 08960 Sant Just Desvern (Barcelona) Phone: 93 480 33 22

www.frigicoll.es www.kaysun.es

DEPARTMENTS (Fax) HVAC and Energy 93 480 33 23 Catering/Hotel and Cooling 93 371 59 10 Household Appliances 93 371 59 10 Transport Refrigeration 93 473 31 40 Spare Parts 93 473 27 02

MADRID Senda Galiana, 1 PolĂ­gono Industrial Coslada 28820 Coslada (Madrid) Phone: 91 669 9701 Fax: 91 674 2100 madrid@frigicoll.es

Kaysun participates in the EUROVENT certification program. The products correspond to those listed into the EUROVENT certified products directory.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.