MARCH 2018
CATALOGUE KAYSUN HVAC systems
www.kaysun.es www.frigicoll.es
Inspiration, Innovation, Evolution
The total or partial reproduction of this catalogue without the express authorisation of Frigicoll S.A. is prohibited.
GENERAL CONTENTS
GENERAL CONTENTS Climate control and energy tariff March 2018
RESIDENTIAL PRODUCT RANGE SUITE 1X1..............................................................................................................28 INTRODUCTION TO THE PRODUCT RANGE.............................................28 SETS...............................................................................................................32 PORTABLE..............................................................................................34 PRODIGY R-32.........................................................................................36 PRODIGY R-410A....................................................................................38 AUREA II R-32 ....................................................................................... 40 AUREA II R-410A ...................................................................................42 ONNIX .................................................................................................... 44 DOUBLE FLOW CONSOLE..................................................................... 46 MULTISYSTEM SUITE........................................................................................ 48 INTRODUCTION TO THE PRODUCT RANGE............................................ 48 R-410A MULTISYSTEM......................................................................... 50 R-32 MULTISYSTEM............................................................................... 51 R-410A OUTDOOR UNITS.......................................................................52 R-32 OUTDOOR UNITS ..........................................................................54 PRODIGY..................................................................................................56 AUREA II................................................................................................. 58 ONNIX .................................................................................................... 60 DOUBLE FLOW CONSOLE .....................................................................62 CASSETTE ............................................................................................. 64 DUCTS.....................................................................................................66 R-410A COMBINED ............................................................................... 68 R-32 COMBINED .....................................................................................78 KEY INSTALLATIONS..................................................................................82
AQUATIX DOMESTIC HOT WATER RANGE INTRODUCTION TO THE PRODUCT RANGE.................................................... 86 UNITS AQUANTIA....................................................SINGLE BLOC..........................94 AQUANTIA....................................................DUAL BLOC............................ 98 DOMESTIC HOT WATER DEPOSITS............BS, G...................................... 102 COMPAK........................................................KHP ACS................................ 106 KEY INSTALLATIONS.......................................................................................108
4
ZEN R-410A COMMERCIAL RANGE INTRODUCTION TO THE RANGE....................................................................114 SETS...................................................................................................................116 CASSETTE (600X600)................................................................................118 SUPERSLIM CASSETTE............................................................................ 120 FLOOR / CEILING....................................................................................... 124 DUCTS........................................................................................................ 128 FLOOR STANDING..................................................................................... 132 TWINS............................................................................................................... 134 KEY INSTALLATIONS..................................................................................... 136
ZEN R-32 COMMERCIAL RANGE INTRODUCTION TO THE RANGE...................................................................140 SETS.................................................................................................................. 142 SUPERSLIM CASSETTE.............................................................................144 FLOOR / CEILING....................................................................................... 146 DUCTS.........................................................................................................148
LARGE-CAPACITY ZEN COMMERCIAL RANGE INTRODUCTION TO THE RANGE................................................................... 152 HIGH-CAPACITY SETS OF DUCTS.................................................................. 153 AIR CONDENSED - FRONT DISCHARGE......154 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN3...........................156 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN4 S....................... 158 WATER-CONDENSED................................................................................160 STATIC PRESSURE GRAPHS..................................................................... 162 KEY INSTALLATIONS..................................................................................... 164
VENTILATION HEAT RECOVERY VENTILATORS RANGE HEAT RECOVERY VENTILATORS..................................................................168 ERP PRO.....................................................................................................170 AZURE........................................................................................................172 STATIC PRESSURE AND EFFICIENCY GRAPHS.......................................174
Inspiration, Innovation, Evolution
VRF INDUSTRIAL AMAZON RANGE INTRODUCTION TO THE RANGE...................................................................... 1 7 8 INDOOR UNITS...................................................................................................184 MURAL........................................................ ...........KAYF...........................188 DOUBLE FLOW CONSOLE......................................KSDF..............................190 FLOOR STANDING EXPOSED/CONCEALED...........KS(E)F...........................192 FLOOR / CEILING........................................ ............KPCF.............................. 194 1-WAY CASSETTE....................................... ............KCOF.............................. 196 ART FLUX 360ยบ (600x600) CASSETTE..................KCIF............................... 198 ART FLUX 360ยบ CASSETTE........................ ............KCIBF............................ 200 DUCTS.......................................................... ............KPDF............................. 202 STATIC PRESSURE GRAPHS.............. .................................................. 204 HIGH PRESSURE DUCTS........................... ............KPDHF.......................... 208 STATIC PRESSURE GRAPHS.............. .................................................. 210 KAHU........................................................... ............KAHU............................ 214 DOMESTIC HOT WATER UNIT...............................KWF............................... 216 OUTDOOR UNITS................................................................................................. 218 2 PIPES ................................................................................................................222 MINI AMAZON II SINGLE-PHASE.................................... .......................KMF DVN2......... 224 THREE-PHASE.............................................................KMF DTN2......... 226 AMAZON SINGLE FRONT AIR DISCHARGE......................KMF................... 228 AMAZON SINGLE VERTICAL AIR DISCHARGE DN3...........K2UF DN3......... 230 AMAZON SINGLE VERTICAL AIR DISCHARGE DN4 S......K2UF DN4 S...... 232 AMAZON IV PRO......................................... .......................K2F DN4S..........236 AMAZON III W............................................. .......................K2F DN3W........ 238 3 PIPES ................................................................................................................ 240 AMAZON III PRO......................................... .......................K3F DN3S.......... 242 INVERTER BOXES................................ .......................KVB.................... 244 SIZING ..................................................................................................................246 DISTANCES AND HEIGHT DIFFERENCES .........................................................256 KEY INSTALLATIONS .........................................................................................262
NEXUS CHILLERS RANGE INTRODUCTION TO THE RANGE..................................................................... 288 CHILLERS.............................................................................................................292 MINICHILLERS FULL DC INVERTER.................KEM D(V)(T)N...................294 MODULAR CHILLERS FULL DC INVERTER...........................................KEM DNS3........................296 MINICHILLERS FULL DC INVERTER WITH HYDRAULIC KIT.......................................KEM DNS3 KH.................298 FIXED SCROLL MODULAR CHILLERS..............KEM HN3......................... 300 EXTERNAL HYDRAULIC KITS...........................KH......................................302 ROTARY SCREW CHILLERS....................................................................... 304 CENTRIFUGAL CHILLERS............................................................................306 KEY INSTALLATIONS....................................................................................... 308
FAN COILS RANGE INTRODUCTION TO THE PRODUCT RANGE...................................................314 UNITS WALL ....................................................................KFC-AY..........................318 FLOOR / CEILING .................................................KFC-S(E)........................320 CASSETTES 600x600 ..........................................KFC-CI............................322 CASSETTES ..........................................................KFC-CIS.........................324 DUCTS ..................................................................KFC-PD..........................326 HIGH-PRESSURE DUCTS ....................................KFC-PDH........................328 KEY INSTALLATIONS.......................................................................................330
CONTROLS CONTROL SYSTEM RANGE INTRODUCTION TO THE PRODUCT RANGE.................................................... 268 OUR RANGE OF PRODUCTS....................................................................... 269 WIRELESS SINGLE CONTROLLERS AND WIRED CONTROLLERS.......... 270 CENTRALISED CONTROLLERS....................................................................272 INTEGRATED CONTROLLERS..................................................................... 274 ACCESSORIES.............................................................................................. 282 KEY INSTALLATIONS........................................................................................ 284
5
BUSINESS GROUP
Who we are Frigicoll is a family-owned Spanish company that has been in operation for more than 60 years, and is a pioneer in the introduction of technological solutions of leading global brands in various sectors of industry. At Frigicoll we undertake comprehensive projects, supplying machinery to the air conditioning, energy, transportation, food and catering and refrigeration sectors, as well as to the household appliances sector.
BUSINESS UNITS IN WHICH WE OPERATE
Transport Refrigeration
Refrigeration
Household appliances
HVAC systems
Hotels/Catering
Spare Parts / After Sales
This is our story: 1957
1969
1975
1985
1988
Fernando Coll Soms began his operations in the automobile sector as an importer and distributor of spare parts and accessories. In the 1960s, he added air conditioning systems and, later, refrigeration equipment for transport to his repertoire.
We opened our first office in Madrid. This period was characterised by a broad vision of the needs of the market and the subsequent diversification of products.
The name of the company was changed to Frigicoll, S.A.
Joint venture created with Thermo King.
A new branch is opened on the Canary Islands.
6
1967
1970
1982
1987
1990
Fernando Coll Soms, S.A. is founded. The company became a distributor of the Liebherr brand.
The company started production of refrigeration units for transport, becoming the only Spanish manufacturer engaged in this activity.
The company became a distributor of Thermo King in Spain.
The climate control business was created.
We established a presence in Portugal.
Inspiration, Innovation, Evolution
OUR VALUES
CSR
Our whole history has been notable for our contribution to the market: the best quality of product, trust, proximity and excellence in customer service and an ongoing quest for improvement and innovation, attributes that have made us leaders in the market. With a long record of providing premium integrated solutions, we face the future with the desire to keep searching for new, sustainable technological solutions.
Corporate social responsibility is one of the fundamental pillars of Frigicoll, carrying out actions based on the growth and social commitment of its employees and actions that help create a better, fairer and more sustainable world.
60 years
+450
+15
of history
employees
facilities spread out across Spain
1996
2002-2011
2012
We consolidated our position, opening two new subsidiaries in Murcia and Valencia.
We started up subsidiaries of the Frigicoll Group in Seville, Lugo, Southern Madrid, Cadiz and Northern Barcelona in the area of refrigeration systems for transport, as well as the Ecliman company, a manufacturer of refrigeration systems designed to improve energy efficiency and environmental protection.
We boosted the central zone with the refurbishment and development of the installations in Madrid (Coslada) and inaugurated the logistics centre in VilaRodona.
2OO million in turnover
2017 We inaugurated our New headquarters in Barcelona, as well as “The Art of Living Frigicoll� in Madrid, a space to display our high-end household appliances .
We reached an agreement with the Midea household appliance brand for the exclusive distribution of their air conditioning units in Spain.
2001
2004
2015
Relocation of our headquarters from Madrid to the municipality of Coslada. In this way, we expanded our presence and positioned ourselves as pioneers and leaders in the Spanish market for high-tech products and first-rate solutions.
We created Kaysun, our brand specialised in both the industrial segment and residential segment with a very clear idea: to transfer all of the experience in products and services at the company to the development of this line of business.
We completed the construction of our Headquarters in the south of Madrid (Getafe) in order to, together with Coslada offices, facilitate access to our customer service bases located in the downtown area.
7
BUSINESS GROUP
Business units
Inventor of the refrigeration system for transport.
Transport Frigicoll offers refrigeration systems for the transportation and distribution of perishable products, climate control for coaches and buses, refrigerated mobile containers and solutions for the transportation of pharmaceutical products. It holds the official concession for the ThermoKing brand in Spain and Portugal and offers technical support through a network of its own workshops and associated services that covers the whole of Spain, with ongoing service available 24 hours a day, 365 days a year.
A pioneer in refrigerated mobile containers.
More than 60 years as leader in the world of cold.
Household appliances Frigicoll offers all equipment for high-end household cooking through the Liebherr, De Dietrich and Falmec brands, leaders in refrigeration, cooking and vacuuming. The three brands are a perfect alliance of design, quality and technology, turning each kitchen into a unique space and guaranteeing the best services for the client.
The best, most powerful induction and the ability to detect recipients.
The most silent extractor hoods in the market (NRS technology).
The first oven with a cloud WiFi connection (Lainox Naboo).
An internal energy cycle that reduces detergent, water and electricity consumption by 50%
Strict temperature and moisture control in laboratory coolers and reliability in gastronomy.
Hotels/Catering Frigicoll offers a wide range of functional equipment with state-of-the-art technology that facilitates the work of professional kitchens. What sets us apart on large premises is the ability to create integrated projects.
Efficiency and high performance in large-scale kitchens and collectives.
The world’s first and only school that specifically provides gourmet pizza training (Pizza University). Plus the following brands:
8
Inspiration, Innovation, Evolution
Cooling units with lower refrigerant charge, if compared to conventional systems, and with improvements in the energy efficiency of the system.
Refrigeration Frigicoll offers complete commercial and industrial refrigeration solutions through own brands such as Frigicoll and Ecliman and through other very prestigious brands such as Dorin and Arneg. Sustainable, highly energy-efficient, robust and reliable solutions.
A complete range of commercial and industrial evaporators.
The mobile cooling unit and compressor that best reflect the trend towards new refrigerants.
We manufacture one in five AC devices worldwide.
Great versatility of equipment and advanced technological innovation.
HVAC systems Frigicoll has an alliance with Midea, a world leader in air treatment equipment, to offer integrated climate control projects suitable for all types of installations, from the residential range to the industrial range. Frigicoll is also present in leading projects worldwide with its own brand, Kaysun, with which it has experienced rapid expansion overseas.
Spare Parts
After-sales service
Frigicoll also has a spare parts business, the aim of which is to provide the best possible service with delivery within 24h and specialist advice and service for each product over the phone, so as to protect the prestige and excellence of the products represented.
To ensure the quality of service at all stages of its value chain, Frigicoll has a highly specialised after-sales service area to foster the agile and effective resolution of any incidents that may arise.
Frigicoll original spare parts • 2,500m2Automated logistics warehouse. • 30,000 parts in stock. • + 200 shipments daily. • + 400,000 parts delivered every year.
Frigicoll after-sales service • ISO 9001 and ISO 14001 • +170 technical assistance points acrossthe whole of the mainland, the Canary Islands and Portugal, as well as 11 service centres. • Uninterrupted service all year round (24/7 in the transport unit).
9
OUR ORIGINS
“A well-established Team” Over more than 60 years, Frigicoll has worked at all times in collaboration with the most reputable brands in the different business units that comprise the company. Our technical team has combined, for each and every project, the premium qualities of our equipment with its professional experience to achieve the best outcomes. Today we complete key installations, noteworthy due to both the technological prowess of their solutions and their social importance. In the HVAC Business Unit, we are proud to apply our first-hand knowledge,acquiredfromourlonghistoryandthebestprofessionals, to the continual development of our own brand, Kaysun, which
grows more established every day with a strong national and international plan. We have a clear goal: to continue providing the best residential and industrial solutions with comprehensive offerings underpinned by a constantly evolving and diverse range of products. That is why we remain loyal to our brand's philosophy – a balance between technology, efficiency, cost and warranty. We believe that the best way to explain to you why Kaysun is rising to the top in the sector is to invite you to experience our work first hand. Thank you for joining us.
Europe France England Ireland Italy Portugal Spain Andorra Belgium The Netherlands Luxembourg Slovenia Malta Romania
The Americas Martinique Guadeloupe French Guiana
Africa Morocco Reunion
10
Inspiration, Innovation, Evolution
“Ten reasons why we stand out�
1
2
THE FRIGICOLL GUARANTEE
Frigicoll is known for its premium products and its broad experience in excellent after-sales services. KAYSUN, the company's own brand, was developed with the standards for quality and technological innovation that have always set us apart.
MAXIMUM RELIABILITY OF OUR EQUIPMENT
6
CUTTING-EDGE TECHNOLOGY
Our forward-looking approach goes hand-in-hand with the incorporation of the latest technology in all of our equipment. We include features that improve everything from energy consumption to practicality and comfort, as in the case of the built-in motorised panel used in cassettes models.
7
SMART CONTROL
We guarantee that our units will have a long service life, thanks to top-quality materials. This ensure that the need to make use of their warranties is reduced to a minimum.
Our smart control devices, allow us to offer comfort and well-being in any facility. The K01-WIFI device is the first smart solution for our units, providing the option of programming and managing air conditioning units inside and outside your home.
ISO
3
ISO 9001 / ISO 14001
The quality of our products and environment benefits are two key pillars for KAYSUN. We are proud to have achieved ISO 9001 and ISO 14001, under the seal of Frigicoll.
4
WIDE RANGE
We offer comprehensive solutions for any facility thanks to the diversity of our product ranges. From residential split systems to the most complex water terminal units, and including air curtains, recovery systems, VRFs, chillers, solar and domestic hot water units.
5
COMPREHENSIVE PROJECTS
Our team of expert technicians carries out HVCA and ventilation comprehensive specific projects for every single customer, which allows our company to be able to adapt to any space and need. A personalised advice complements this service, thus ensuring the correct performance of our installation works.
8
COMMITTED TO THE ENVIRONMENT
Our equipment is manufactured almost entirely from recyclable materials. We have reduced consumption as far as possible in STANDBY mode and have improved the energy efficiency of units working at full capacity, resulting in energy savings for facilities.
9
EXCELLENT AFTER-SALES SERVICE
We work to solve all incidents as quickly as possible, leaving our customers completely satisfied with our after-sales service. We have a team of expert professionals working for you.
10
THE BEST MANAGEMENT OF SPARE PARTS IN THE SECTOR
We understand the key role of air-conditioning systems play in our facilities, and we offer unbeatable replacement services. Our commitment is absolute and we offer immediate solutions.
11
EUROPEAN DIRECTIVE ERP
EUROPEAN DIRECTIVE ErP Kaysun remains committed to inspiration, innovation and evolution. That is why it is proud to present a 2018 catalogue in which all products meet the requirements of the new energy regulations in force.
Icons for the 2018 catalogue. Green colour, which stands for ecological innovation, is hard to miss in our 2018 catalogue, showing the energy efficiency of each of our products. ErP
SCOP
SEER
ErP
ECODESIGN DIRECTIVE On January 1st, 2013 the "ecodesign" directive took effect, which in order to reduce energy consumption and benefit the environment, requires the adoption of legal measures to establish requirements for energy labelling and supplying energy-related information about products. The Commission adopted Regulation 626/2011, introducing the new energy labels which are mandatory for air conditioning units connected to the grid with a nominal refrigerating power (or nominal heating power, if the unit only runs as a heat pump) of less than 12kW.
These labels contain seasonal energy performance levels, which are based on different outdoor temperatures and part-load efficiencies to calculate a level of annual consumption in extremely close detail, thus demonstrating in the most apparent manner possible the advantages of the Inverter technology used by Kaysun. The sound level rating of the unit is also displayed. It is important to make the distinction between SEER and SCOP, where “S” stands for “Seasonal” to indicate the seasonal variation of annual energy consumption, which is usually measured according to the hours a unit runs in different climatic zones over a year.
ENERGY EFFICIENCY CLASSES for air conditioners CLASSES*
SEER
SCOP
A+ + +
SEER ≥ 8,50
SCOP ≥ 5,10
A+ +
6.10 ≤ SEER < 8.50
4.60 ≤ SCOP < 5.10
A+
5.60 ≤ SEER < 6.10
4.00 ≤ SCOP < 4.60
A
5.10 ≤ SEER < 5.60
3.40 ≤ SCOP < 4.00
B
4.60 ≤ SEER < 5.10
3.10 ≤ SCOP < 3.40
C
4.10 ≤ SEER < 4.60
2.80 ≤ SCOP < 3.10
D
3.60 ≤ SEER < 4.10
2.50 ≤ SCOP < 2.80
(*) with the exception of dual and single duct units.
Minimum energy efficiency values have been established for both cooling and heating mode for all products for sale after January 2013 to which that regulation applies. Inefficient products will
12
not be able to be sold on the European market, since they do not meet the requirements of the mentioned regulation.
Inspiration, Innovation, Evolution
We would like to note that there are also restrictions regarding sound levels, and therefore Kaysun offers efficient and environmentally friendly products that provide comfort and a quality lifestyle to end users.
MINIMUM ENERGY EFFICIENCY REQUIREMENTS ACOUSTIC POWER IN dB(A)
NOMINAL POWER
≤ 6kW
≤ 12kW
Indoor
60
Outdoor
65
Indoor
65
Outdoor
70
MINIMUM ENERGY EFFICIENCY REQUIREMENTS 2015 NOMINAL POWER
GWP OF THE REFRIGERANT
AIR CONDITIONERS SEER
DUAL DUCT
SCOP
EER
SINGLE DUCT COP
EER
COP
If the GWP > 150
4.60
3.80
2.60
2.60
2.60
2.04
If the GWP < 150
4.14
3.42
2.34
2.34
2.34
1.84
If the GWP > 150
4.30
3.80
2.60
2.60
2.60
2.04
If the GWP < 150
3.87
3.42
2.34
2.34
2.34
1.84
< 6KW
6 - 12 KW
ENERGY LABELS The label makes a distinction between climatic areas, and therefore offers users more detailed information and a more accurate idea of the efficiency of the units according to the climatic area in which they are located. In addition to the Ecodesign directive, there is another directive hat affects Kaysun. All units with fans with a motor that consumes between 125W and 500 kW of energy meet certain minimum energy efficiency requirements.
CLIMATIC ZONES The map below shows the three climatic zones that have been established for a better evaluation: Average (*) Annual temperature of Strasbourg. Hot Annual temperature of Athens. Cold Annual temperature of Helsinki.
SEER and SCOP. These values indicate the Seasonal Energy Efficiency Ratio for refrigerating (SEER) and heating (SCOP) calculated based on annual hours of use in different climatic zones. ENERGY CLASS For heating and cooling, labels will increase up to Class A+++. SOUND LEVELS The sound level of indoor and outdoor units, expressed in decibels.
(*) It is only mandatory to express the SCOP for the average climate zone.
13
OUR RANGES
SUITE RESIDENTIAL PRODUCT RANGE 2.0 R-410A
PORTABLE
2.8
3.5
4.2
4.8
5.2
6.2
7.1
7.8
8.0
10.5
NEW
12.0
14.0
16.0
kW pag. 34
R-32 NEW
R-410A
SUITE 1x1
2.6
PRODIGY
36-38
AUREA II
40-42
R-410A
R-410A
ONNIX
44
R-410A
CONSOLE
46
R-32 NEW
R-410A
PRODIGY
56
AUREA II
58
R-410A
R-410A
60
ONNIX
R-32 NEW
R-410A
62
CONSOLE
MULTI TYPE
R-410A
R-32 NEW
64
CASSETTE
NEW
R-410A
66
DUCTS
2x
2x
R-410A
3x
3x
52
OUTDOOR 4x 5x 2x 3x
54
OUTDOOR 4x 5x
14
Inspiration, Innovation, Evolution
AQUATIX
DOMESTIC HOT WATER RANGE
AQUANTIA SINGLE BLOC
4
5
HEAT PUMP
8
12
14
16
kW pag.
94
THREE-PHASE
94
5
6
7
8
12
14
16
kW pag.
SINGLE-PHASE
98
THREE-PHASE
98
130
180
230
280
330
L
COMPAK
TANKS FOR DOMESTIC HOT WATER
pag.
106
160
DEPOSITS
7
SINGLE-PHASE
4
AQUANTIA DUAL BLOC
6
190
270
475
750
1000
1250
1500
1750
2000
2225
2500
L
pag.
102
15
OUR RANGES
ZEN
COMMERCIAL RANGE 2.6
R-410A
600x600 CASSETTE
SUPERSLIM CASSETTE
1X1 SYSTEMS
FLOORCEILING
7.1
9.0
10.5
12.5
14.0
16.0
20.0
25.0
28.0 40.0 45.0
56.0
kW
pag.
121 122
.
OUTDOOR AXIAL OUTDOOR CENTRIFUGE
R-410A
.
OUTDOOR AXIAL OUTDOOR CENTRIFUGE
R-410A
5.2
118 OUTDOOR CENTRIFUGE
R-410A
3.5
125 126
.
129
DUCTS NEW
OUTDOOR CENTRIFUGE
R-410A
R-410A
FLOOR STANDING WHILE STOCKS LAST
R-410A
OUTDOOR AXIAL
600x600 CASSETTE
OUTDOOR AXIAL
130
.
133 133 135 135
R-410A
SUPERSLIM CASSETTE
TWINS
135 R-410A
135
FLOOR-CEILING
135 R-410A
135 DUCTS NEW
16
135
Inspiration, Innovation, Evolution
ZEN
COMMERCIAL RANGE 2.6
3.5
5.2
7.1
9.0
10.5
12.5
14.0
16.0
20.0
25.0
28.0 40.0 45.0
56.0
kW
SUPERSLIM CASSETTE
pag. 144
1X1 SYSTEMS
R-32
R-32 NEW
FLOORCEILING
146
R-32 NEW
DUCTS
148
NEW
AIR CONDENSED
FRONT AIR DISCHARGE
VERTICAL AIR DISCHARGE DN3
154 156
R-410A
VERTICAL AIR DISCHARGE DN4
WHILE STOCKS LAST
158
R-410A
WATER CONDENSED
HIGH CAPACITY
R-410A
NEW
160
R-410A
VENTILATION
HEAT RECOVERY
500
700
AIR CURTAINS AND HEAT RECOVERIES PRODUCT RANGE 800
900
1000 1200 1400 1800 2000 2300 2400 2600 2800 3000 3200 m3/h
TYPE
pag.
ERP PRO
VENTILATORS 170
AZURE
VENTILATORS 172
17
OUR RANGES
AMAZON
INDUSTRIAL VRF RANGE 1.5
HIGH WALL DOUBLE FLOW CONSOLE FLOOR STANDING EXPOSED/ CONCEALED
FLOOR / CEILING
INDOOR UNITS
CASSETTE 1 WAY CASSETTE 600X600 CASSETTE 840X840 Ducts HIGH PRESSURE DUCTS DOMESTIC HOT WATER KAHU MINI AMAZON II SINGLE-PHASE MINI AMAZON II THREE-PHASE
2 PIPES
OUTDOOR UNITS
AMAZON UNITARIO FRONT AIR DISCHARGE AMAZON UNITARIO VERTICAL AIR DISCHARGE DN3 AMAZON UNITARIO VERTICAL AIR DISCHARGE DN4 AMAZON IV PRO
3 PIPES
AMAZON III W
18
AMAZON III PRO
2.2
2.8
3.6
4.5
5.6
7.1
8.0
9.0
10.0
11.2
12.0
14.0
Inspiration, Innovation, Evolution
16.0
18.0
20.0
22.4
25.0
25.2
26.0
28.0
33.5
40.0
45.0
50.0
56.0
61.5
67.0
73.0
75.0
90.0
kW
Pag. 188 190 192 194 196 198 200 202 208 216 214 224 226 228 230 232 236 238
242
19
OUR RANGES
CONTROLS
CONTROL SYSTEM RANGE SUITE
WIRELESS
PRODIGY 1x1
AUREA II 1x1
ZEN
ONNIX 1x1
MULTI
CONSOLE 1x1
Pag.
KID-02 S
270
KI-02.3 S
270
KC-01 S
INDIVIDUAL WIRED
AMAZON
Except for Aurea II
SuperSlim Cassette and Floor Standing models
270
only Ducts
SuperSlim Cassette and Floor Standing models
271
only Ducts
Except for SuperSlim Cassette and Floor Standing models
271
Except for Aurea II model
Except for SuperSlim Cassette and Floor Standing models
271
Except for Aurea II model
Except for SuperSlim Cassette and Floor Standing models
271
KC-03 SPS KC-03.1 SPS NEW
KC-02.1 H
KCT-02.1 SR
272
CENTRALISED CONTROLS
KMC-32 E
KCCT-64 I (B) KCCT-64 IPS NEW
KCCT-384 IPS NEW
KCC-64 WEB
Except for wallmounted and KSD models
272
Except for wallmounted and KSD models
272
Except for wallmounted and KSD models
273
Except for wallmounted and KSD models
273
NEXUS CHILLERS PRODUCT RANGE 5
7
10
12
14
16
26
30
35
52
65
71
95
130
160
195
200
225
250
Single-phase MINICHILLERS INVERTER
CHILLERS
Tri-phase
MODULAR FULL DC INVERTER CHILLERS MODULAR CHILLERS
ROTARY SCREW CHILLERS
4x
Without hydraulic kit With hydraulic kit
4x
Fixed Scroll
20
4x
4x
Air-water
Water-water
2 CHILLERS CENTRIFUGAL
4x
3
4
Check your model
5
260
315
340
Inspiration, Innovation, Evolution
SUITE
AMAZON
MULTI
pag.
K01-LON
except for wallmounted and KSD models
274
K01-BACNET
Except for wallmounted and KSD models
276
Except for wallmounted and KSD models
275
Except for wallmounted and KSD models
275
Except for wallmounted and KSD models
280
Except for wallmounted and KSD models
277
PRODIGY 1x1
INTEGRATED CONTROLS
ZEN
AUREA II 1x1
ONNIX 1x1
CONSOLE 1x1
K02MODBUS
K01MODBUS
KAYNET CONTROL
K01-KNX
278
ACCESSORIES
K01 WIFI
K01-WATT
283
Except for MiniAmazon II models
282
KAHU
380 400 435 440 500
510
520 540 565 600 620 630 640 685 690 720
740
750
760 805
815
900 1000 1100 1200 1385 1620 1780
kW pag. 294 294 296 298 300
6
Check your model
304
Check your model
305
7
Check your model
8
9
10
MW 306
21
OUR RANGES
FANCOILS
WATER TERMINAL UNITS PRODUCT RANGE 370
490
540
INDOOR UNITS
HIGH WALL 2 DUCTS
FLOOR / CEILING 2 PIPES
600
680
750
780
980
1500
m3/h pag.
318
EXPOSED
320
CONCEALED
320
2 DUCTS
322
4 DUCTS
322
CASSETTE 600 X 600
340
510
600
680
730
1020 1175 1230 1360 1450 1530 1580 1700 1870 2380 3060 3740 m3/h pag.
2 DUCTS
324
4 DUCTS
324
2 DUCTS
326
4 DUCTS
326
2 DUCTS
328
INDOOR UNITS
CASSETTE
Ducts
HIGH PRESSURE DUCTS
22
REFRIGERANT
R-134A
R-32
ICONS
R-134A REFRIGERANT The units works with R-134A ecological refrigerant.
DESCRIPTION
R-32 REFRIGERANT The unit works with R-32 ecological refrigerant.
MULTIPLE AIR INLETS This unit is fitted with four air return inlets: upper inlet, lower inlet, right inlet and left inlet.
R-410A REFRIGERANT The units works with R-410A ecological refrigerant.
FRESH AIR SUPPLY “X %” of fresh air directly enters the indoor unit through an orifice.
MODULAR Can be combined with other units up to power "x", by connecting the inlet and outlet pipes between units. SUPER SLIM The new Super Slim cassette can be fitted into any space. ErP Unit that complies with the European Parliament and Council of the European Union's Directive which establishes the ecological design requirements applicable to products that use energy.
AUTOMATIC ADJUSTMENT OF THE BLADES The unit has the capacity to automatically position the blades at the same angle that they were at when it was shut off the last time.
4.0
SCOP 4.0 The heat pump performance of a set of units exceeds SCOP 4.0.
AIR OUTLET 360º The indoor unit is capable of spreading a 360º air flow, thus providing high comfort and reaching all corners of the room.
A
SEER Classification of energy efficiency according to seasonal performance for cooling.
8ºC HEATING This feature keeps the temperature in the room from dropping below 8ºC by turning on the unit automatically in heat mode until it reaches 17ºC.
DRAINAGE PUMP A system which is capable of removing condensate up to 750 mm.
SELF-CLEANING A feature of the indoor unit which automatically cleans the machine's battery so as to continue providing fresh, purified air every day.
TWO COMMUNICATION WIRES The system uses two shielded communication wires without polarity.
LOW SOUND LEVEL New technological advances have allowed the level of sound produced by the indoor units to be reduced by up to 20 dB.
SCOP
++
x2
AIR OUTLET The unit has two air outlets: upper and lower.
ADDRESSING The control system allows setting an address for indoor units inside the communication bus. 50/60 Hz
TWINS
ACS
DC
INVERTER
HERTZ The units can function at 50 or 60 Hz. MOTORIZED PANEL This type of panel descends automatically by up to 4 metres to facilitate the maintenance and cleaning of the filter.
EYE DETECTOR A function that automatically turns off the unit when the sensor does not detect movement in the room for 30 minutes. The unit will switch on again when someone enters the room.
SOLAR PANEL A very efficient set of equipment which exploits the sun's energy using a solar panel.
FOLLOW ME A feature which changes the operating mode based on the remote controlled temperature sensor with the aim of maintaining maximum comfort.
TWINS Connection system that allows the two indoor units to be combined with an outdoor unit, making installation easier and more economical.
INTELLIGENT This feature allows changing the operation parameters of the unit and extracting operation data.
DOMESTIC HOT WATER A system that produces domestic hot water and underfloor heating. DC INVERTER COMPRESSOR This feature allows to regulate the power of the compressor, providing optimum control and extremely efficient operation.
LED DISPLAY The indoor unit displays the information on a digital display panel.
ECO MODE A control feature which reduces consumption, offering high energy efficiency thanks to automatic temperature regulation. NIGHT MODE A feature of the indoor unit which reduces the sound level during the night for a more comfortable sleep.
-
TURBO
COOLING AND HEATING Our units are equipped with air conditioning and a heat pump.
SILENCE MODE A function of the indoor unit that reduces sound pressure using the lowest speed of the fans.
1W
3D TECHNOLOGY Triple DC inverter technology that allows a more constant temperature, high energy saving and significant energy efficiency. DC
INVERTER
DC
INVERTER
INDOOR
DC INVERTER EXTEERNAL FAN The unit is fitted with a DC Inverter external fan. DC INVERTER INTERNAL FAN The unit is fitted with a DC Inverter internal fan.
TURBO MODE This feature reaches the selected temperature within a very short time.
WEEKLY PROGRAMMER A control feature which schedules when the unit will turn on/shut off according to the day and time during the week.
ROTARY Unit fitted with a rotary heat exchanger to provide a higher air flow. SCROLL The unit is fitted with a highly efficient and powerful scroll compressor.
+
MUTE This feature allows permanently cancelling the indoor unit alarm beeper.
HYDRAULIC KIT A complete, built-in hydraulic kit. KIT
OUTDOOR
AUTOMATIC MODE The indoor unit automatically changes to heating or cooling operating mode based on the temperature selected.
AUTO
CONDENSATION CONTROL Allows the system to refrigerate, even with low outdoor temperatures. SIMULTANEOUS COOLING/HEATING Heat recovery technology which allows cold and heat to be obtained simultaneously within the same system, optimising the user's comfort.
SCROLL
SWITCH OFF DISPLAY This feature allows switching off the display of the indoor units, if necessary.
24ºC 24ºC
SCREW COMPRESSOR Unit fitted with a screw compressor suitable for high compression ratio.
!
REFRIGERANT CONTROL A sensor on the outdoor unit and an alarm on the indoor unit's display alert the user of the detection of a possible refrigerant leak.
!
COMFORT COMFORT
ENERGY
AIR INTAKE The indoor unit has two possible air intakes: the upper and the rear intake.
SCOP Classification of energy efficiency according to seasonal performance for heating.
SCOP
SEER
INSTALLATION AND SERVICE
A B
A
++
TECHNOLOGY
AUTO SWING The wide angle of rotation of the horizontal and vertical blades guides the cold or hot air, creating a flow capable of reaching any corner of the space.
AIR DISTRIBUTION
DESIGN
COMPACT Advances in design have reduced the size of the indoor and outdoor units without overlooking any technological details.
STAND BY The "standby mode" feature allows 80% energy saving with only 1W consumption by the LED display. TOUCH SENSITIVE KEYS The keys of the remote control are touch sensitive.
+ -
COMPENSATION TEMPERATURE The possibility of compensating for the difference in temperature between the indoor unit's sensor and the real temperature of the room in heating mode. Wi-Fi This unit can be controlled by a Wi-Fi network through a smartphone application.
23
CATALOGUE
KAYSUN HVAC systems
SUITE RESIDENTIAL PRODUCT RANGE SUITE 1X1...............................................................................................28 INTRODUCTION TO THE PRODUCT RANGE.........................28 SETS..........................................................................................32 PORTABLE..........................................................................34 PRODIGY R-32.....................................................................36 PRODIGY R-410A................................................................38 AUREA II R-32 ....................................................................40 AUREA II R-410A ...............................................................42 ONNIX .................................................................................44 DOUBLE FLOW CONSOLE..................................................46
MULTISYSTEM SUITE..........................................................................48 INTRODUCTION TO THE PRODUCT RANGE.........................48 R-410A MULTISYSTEM.............................................................50 R-32 MULTISYSTEM.................................................................51 R-410A OUTDOOR UNITS.........................................................52 R-32 OUTDOOR UNITS .............................................................54 PRODIGY....................................................................................56 AUREA II....................................................................................58 ONNIX .......................................................................................60 DOUBLE FLOW CONSOLE ........................................................62 CASSETTE .................................................................................64 DUCTS........................................................................................66 R-410A COMBINED ...................................................................68 R-32 COMBINED .......................................................................78 KEY INSTALLATIONS.............................................................82
SUITE RESIDENTIAL
SUITE
RESIDENTIAL PRODUCT RANGE
27
RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
SUITE 1x1 RESIDENTIAL PRODUCT RANGE
“ELEGANCE
Introducing our 1x1 residential units range. KAYSUN endeavours to offer the most complete range suitable for any type of aesthetic and requirement. Contributing to the maximum well-being of the user, at the vanguard of innovation and with a proposal that meets all of the requirements of the market and contains developments that constitute pioneering advances in the sector. The residential range units comply with the ERP (energyrelated products) directive of the EU, offering SCOP values of A, A+ and A++. The brand wishes to consolidate its position in the market by offering products with a seasonal energy efficiency
PRODIGY
AND COMFORT FOR YOUR HOME” under heat mode that are even higher than 4 in SCOP for some of its models. Therefore, we not only observe the current directives on energy efficiency, but future directives as well.
R-32 NEW
In its search for the best combination of efficiency and comfort, KAYSUN brings professional technological development to the end-user. The PRODIGY unit has been created to become the new emblem of domestic split equipment, and is positioned in the market as an unbeatable commitment to our fundamental values.
R-410A 28
+
EFFICIENCY
+
INTERACTIVITY
+
INSTALLATION
+
MAINTENANCE
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
INSTALLING • Installation template included and integral, strong and simple support. When installing the unit, leave a 50mm side shift margin.
• Fasteners system for supporting working on electrical connections.
front
panel
while
• The electric connection board is wide and strong.
• The unit's support is fitted with a hinge system, which provides 168 mm opening to allow for cooling and discharge connection.
INFORMATION SERVICING
+
EASY AND COMFORTABLE ACCESS TO THE FILTER WITHOUT DISASSEMBLING THE UNIT
+
SIMPLE AND QUICK OPENING THANKS TO ITS ROTATING FRONT PANEL.
+
FAN MAINTENANCE WITHOUT TAKING THE UNIT OFF THE WALL.
+
EASY ACCESS TO ELECTRONIC BOARD AND TO THE COMPLETE ELECTRICAL PANEL TO PERFORM CHECKING OR REPLACEMENT OPERATIONS.
+
EASY ACCESS TO EVAPORATOR IN CASE THAT CLEANING OR REPLACEMENT TASKS ARE REQUIRED.
29
RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
AUREA II With its elegant design, the main characteristic of this unit is that it works with both R-32 and R-410A refrigerant and incorporates all KAYSUN technology, with the most advanced functions in the range as a result.
+ +
PARAMETERS AND CONFIGURATION BY REMOTE CONTROLLER
LEAKAGE DETECTION SYSTEMS
+ +
SCOP OVER 4.0
WIFI CONTROL (OPTIONAL)
R-410A
OUTDOOR UNITS We wish to point out the whole range of outdoor units in the Kaysun SUITE RANGE. These units provides us with low noise levels, good performance and significant energy savings. A machine designed to make maintenance tasks easier and protect its main components in order to extend the useful life of the product.
+ +
R-410A
+
GREATER OUTPUT
ENERGY SAVING
SOUND LEVELS REDUCTION
• Strong structure.
• Compact finishing.
30
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
APP/WIFI KAYSUN has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.
+
WEEKLY TIMER
+
CHECK
+
BASIC FUNCTIONS
K03 WIFI USB ACCESSORY
DOWNLOAD OUR APPLICATION FROM:
www.kaysun.es
+
PLUG & PLAY
R-32 REFRIGERANT UNITS Frigicoll, by means of its KAYSUN brand have already started marketing some of its products fitted with R-32 refrigerant. The new EU regulations encourages the use of alternative gases, such as R-32 refrigerant gas. The R-32 has a 675 global warming potential (GWP), a very low rate if compared to the 2,088 GWP produced by R-410A refrigerant. It is more cost-efficient, 10 % more suitable and reduces charge volume by 25% because it is more compact. In addition, it offers better performance at an extreme outdoor temperature and is easy to reuse and recycle, as it is made up of a single refrigerant component.
PRODIGY
AUREA II
31
RESIDENTIAL PRODUCT RANGE POWER RANGE
SETS AND PORTABLE UNITS SUITE 1x1
32 32
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
2.6
5.2
7.1
KAY-35 DR8
KAY-52 DR8
KAY-71 DR8
KAY-35 DN8
KAY-52 DN8
KAY-71 DN8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
KAY-S 26 DN8
KAY-S 35 DN8
KAY-S 52 DN8
KAY-S 71 DN8
KAY-D 26 DN7
KAY-D 35 DN7
POWER kW
3.5
NEW
PORTABLE (Page 34)
KP-35 HN8
R-410A PRODIGY R-32
(Page 36) KAY-26 DR8
PRODIGY R-410A
R-410A
(Page 38)
KAY-26 DN8
AUREA II R-32
(Page 40) KAY-S 26 DR8
AUREA II R-410A
R-410A ONNIX
NEW
(Page 42)
(Page 44) KAY-D 52 DN7
R-410A DOUBLE FLOW CONSOLE
(Page 46) KSD-35 DVN11
R-410A
DISTANCES AND HEIGHT DIFFERENCES 26
35
52
71
TOTAL LENGTH
25
25
30
50
MAXIMUM HEIGHT
10
10
20
25
Note: The SUITE 1x1 range is currently in the process of obtaining the EUROVENT Certification.
33 33
RESIDENTIAL PRODUCT RANGE PORTABLE
PORTABLE
NEW
TECHNICAL SPECIFICATIONS MODEL
KP-35 HN8
Cooling capacity
kW
Cooling capacity
Kcal/h
3010
W
1350
Cooling input EER
2.6
Cooling energy class Air flow Sound pressure
A 3
m /h
386
dB (A)
65
Refrigerant Width/Height/Depth Net weight Power supply
34 34
3.5
R-410A mm
466/765/397
Kg
30
V / F / Hz
220-240/1/50
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
1W
R-410A
GENERAL CHARACTERISTICS
This year 2018 we introduce a new product: KAYSUN portable. A Cooling Mode Only unit fitted with R-410A refrigerant, it is easy to transport and place in any room of the house and includes a condensate auto-evaporation system. • The unit has 4 wheels to move it around the house and place it anywhere at our convenience. • Condensate auto-evaporation system.
• Auto-restart function. • Self-protection and self-diagnosis functions. • Timer On/Off function.
• Wireless controller included. • Control panel at the top of the unit.
KID-01 S STANDARD
+ +
EASY TO TRANSPORT
WIRELESS CONTROLLER INCLUDED
35 35
RESIDENTIAL PRODUCT RANGE CASSETTE
PRODIGY R-32
NEW
TECHNICAL SPECIFICATIONS SET
KAY-26 DR8
Cooling capacity (min./rated/max.)
kW
Cooling capacity (min./rated/max.)
Kcal/h
KAY-52 DR8
KAY-71 DR8
1.41/3.52/4.57
1.96/5.28/6.21
3.05/7.33/8.44
1213/3027/3930
1686/4541/5341
2623/6304/7258
100/700/1320
110/1250/1740
150/1500/2220
230/2260/3010
SEER
6.8
6.3
6.7
6.4
Cooling energy class
A++
A++
A++
A++
Cold input capacity (min./rated/max.)
W
1.20/2.64/3.43
KAY-35 DR8
1032/2270/2950
Cooling capacity (min./rated/max.)
kW
0.82/2.93/3.87
0.88/4.10/5.13
1.29/5.57/6.98
2.08/7.62/9.44
Cooling capacity (min./rated/max.)
Kcal/h
705/2520/3328
757/3526/4412
1109/4790/6003
1789/6553/8118
W
140/780/1380
150/1170/1830
220/1390/2330
330/2110/3150
SCOP
4.0
4.0
4.0
4.0
Heating efficiency class
A+
A+
A+
A+
SCOP (warm areas)
5.1
5.2
5.1
5.1
A+++
A+++
A+++
A+++
2.15
2.32
3.92
4.99
2.91
2.81
2.80
2.50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Heat input capacity (min./rated/max.)
Heating energy class (warm areas) Heating capacity -7ºC
kW
COP -7ºC Power supply
V / F / Hz
INDOOR UNIT
KAY-26 DR8
KAY-35 DR8
KAY-52 DR8
KAY-71 DR8
Air flow
3
m /h
486/433/329
550/490/360
810/720/550
1050/970/650
Sound pressure (Silence)
dB (A)
21
23
24
27
Width x Height x Depth
mm
717/302/193
805/302/193
964/325/222
1106/342/232
Net weight
Kg
7.5
8.2
10.8
14.3
Power wiring
mm2
From outdoor
From outdoor
From outdoor
From outdoor
Communication wiring
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
OUTDOOR UNIT
KAE-26 DR8
KAE-35 DR8
KAE-52 DR7
KAE-71 DR7
Compressor type
Rotary
Rotary
Rotary
Rotary
Outdoor airflow
m3/h
2000
2000
2100
2700
Sound pressure
dB (A)
55
55
57
59
R-32
R-32
R-32
R-32
700/12
800/12
1250/12
1600/24
Refrigerant Refrigerant charge / Supplementary charge **
gr
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9(5/8")
Piping max. length
m
25
25
30
50
Pipe height difference
m
10
10
20
25
Width/Height/Depth
mm
770/555/300
770/555/300
800/554/333
845/702/363
Net weight
Kg
26.4
26.5
37
48
Power wiring
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Communication wiring
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
36 36
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
4.0 R-32
50/60
SCOP
24ºC
!
!
Hz
1W
24ºC
GENERAL CHARACTERISTICS
PRODIGY is the new KAYSUN wall unit. It represents a revolution in installation and preventive maintenance*. Easy installation and maintenance and fitted with Kaysun avant-garde TECHNOLOGY. •
Optional WIFI control adding K03 WIFI USB.
•
Drainage pipe connection from left or right option.
•
Multisystem compatible unit
•
•
Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status.
SCOP 4.0, over European Directive ERP, for a high energy efficiency.
•
Self-locking option for Heating-Only function.
•
Display and comfort.
•
Compatible with wired controllers.
•
KID-02 S controller included to control unit's work parameters and change its configuration.
•
Leakage detection system.
•
Louvers position storage.
buzzer
switch-off
to
improve
ambient
+
EASY ASSEMBLY AND MAINTENANCE
+
WIFI CONTROL (OPTIONAL)
ErP ErP
OPTIONAL WIFI
K03 WIFI USB ACCESSORY
KID-02 S STANDARD
* For further information, please check the Presentation section of this manual.
SINGLE
For further information, please see our Controllers range BMS AND SOFTWARE
INDIVIDUAL
KC-01 S
KC-02.1 H
KCT-02.1 SR
K01-WIFI
37 37
RESIDENTIAL PRODUCT RANGE CASSETTE
PRODIGY R-410A TECHNICAL SPECIFICATIONS SET
KAY-26 DN8
KAY-35 DN8
KAY-52 DN8
KAY-71 DN8
Cooling capacity (min./rated/max.)
kW
1.17/2.64/3.31
1.26/3.52/4.45
1.90/5.28/6.13
2.67/7.03/7.88
Cooling capacity (min./rated/max.)
Kcal/h
1008/2268/2848
1084/3024/3830
1638/4536/5267
2293/6048/6779
W
100/816/1270
110/1153/1720
150/1643/2350
230/2306/3030
SEER
6.7
6.7
6.8
6.4
Cooling energy class
A++
A++
A++
A++
Cold input capacity (min./rated/max.)
Cooling capacity (min./rated/max.)
kW
0.82/2.93/3.72
1.07/3.81/4.86
1.43/5.57/6.74
2.08/7.62/9.14
Cooling capacity (min./rated/max.)
Kcal/h
706/2520/3200
917/3276/4183
1227/4788/5796
1789/6552/7862
W
140/811/1330
170/1055/1740
230/1586/2400
310/2302/3270
SCOP
4.1
4.2
4.1
4.0
Heating efficiency class
A+
A+
A+
A+
SCOP (warm areas)
5.1
5.2
5.5
5.2
A+++
A+++
A+++
A+++
2.12
2.30
3.89
4.95
2.88
2.79
2.78
2.48
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Heat input capacity (min./rated/max.)
Heating energy class (warm areas) Heating capacity -7ºC
kW
COP -7ºC Power supply
V / F / Hz
INDOOR UNIT
KAY-26 DR8
KAY-35 DR8
KAY-52 DR8
KAY-71 DR8
Air flow
3
m /h
486/433/329
550/490/360
810/720/550
1050/970/650
Sound pressure (Silence)
dB (A)
21
23
24
27
Width x Height x Depth
mm
717/302/193
805/302/193
964/325/222
1106/342/232
Net weight
Kg
Power wiring
mm
2
Communication wiring
mm
2
OUTDOOR UNIT Compressor type
7.5
8.2
10.8
14.3
From outdoor
From outdoor
From outdoor
From outdoor
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
KAE-26 DN7
KAE-35 DN7
KAE-52 DN7.1
KAE-71 DN7
Rotary
Rotary
Rotary
Rotary
Outdoor airflow
3
m /h
1900
2000
2200
2700
Sound pressure
dB (A)
55
56
56
61
R-410A
R-410A
R-410A
R-410A
gr
800/15
950/15
1350/15
2000/30
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9(5/8")
Piping max. length
m
25
25
30
50
Pipe height difference
m
10
10
20
25
Width/Height/Depth
mm
770/555/300
800/554/333
800/554/333
845/702/363
Net weight
Kg
26.6
29.1
35.1
48.4
Refrigerant Refrigerant charge / Supplementary charge **
Power wiring
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Communication wiring
mm
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
2 2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
38 38
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
4.0 R-410A
50/60
SCOP
Hz
24ºC
!
!
1W
24ºC
GENERAL CHARACTERISTICS PRODIGY is the new KAYSUN wall unit. It represents a revolution in installation and preventive maintenance*. Easy installation and maintenance and fitted with Kaysun avant-garde TECHNOLOGY. • Optional WIFI control adding K03 WIFI USB.
• Drainage pipe connection from left or right option.
• Multisystem compatible unit
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• Its white translucent smart DISPLAY provides user with information on the equipment and alarm systems status. • Display and comfort.
buzzer
switch-off
to
improve
ambient
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Self-locking option for Heating-Only function. • Compatible with wired controllers. • Leakage detection system.
• Louvers position storage.
+
EASY ASSEMBLY AND MAINTENANCE
+
WIFI CONTROL (OPTIONAL)
OPTIONAL WIFI
ErP ErP
K03 WIFI USB ACCESSORY
KID-02 S STANDARD
* For further information, please check the Presentation section of this manual.
SINGLE
For further information, please see our Controllers range BMS AND SOFTWARE
INDIVIDUAL
KC-01 S
KC-02.1 H
KCT-02.1 SR
K01-WIFI
39 39
RESIDENTIAL PRODUCT RANGE CASSETTE
AUREA II R-32 TECHNICAL SPECIFICATIONS SET
KAY-S 26 DR8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
0.82/3.52/4.16
1.73/5.28/6.21
2.58/7.33/8.44
Cooling capacity (min./rated/max.)
kW
1.03/2.64/3.19
Cooling capacity (min./rated/max.)
Kcal/h
886/2270/2743
705/3027/3578
1487/4536/5342
2218/6300/7257
W
70/749/1230
50/1089/1600
120/1538/2390
230/2402/3350
7.1
7.0
6.4
6.4
A++
A++
A++
A++
Cold input capacity (min./rated/max.) SEER Cooling energy class Cooling capacity (min./rated/max.)
kW
0.88/2.93/3.66
0.85/3.81/4.78
1.06/5.57/6.98
1.52/7.62/9.44
Cooling capacity (min./rated/max.)
Kcal/h
756/2520/3148
731/3277/4111
907/4788/5997
1310/6552/8114
W
140/715/1310
130/1050/1710
190/1461/2490
230/2177/3370
SCOP
4.0
4.1
4.0
4.0
Heating efficiency class
A+
A+
A+
A+
SCOP (warm areas)
5.2
5.1
5.1
5.1
A+++
A+++
A+++
A+++
2.15
2.32
3.92
4.99
2.91
2.81
2.80
2.50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Heat input capacity (min./rated/max.)
Heating energy class (warm areas) Heating capacity -7ºC
kW
COP -7ºC Power supply
V / F / Hz
INDOOR UNIT
KAY-S 26 DR8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
Air flow
m3/h
521/429/259
539/478/294
750/505/420
1050/750/560
Sound pressure (Silence)
dB (A)
20
21
21
26
Width/Height/Depth
mm
722/290/187
802/297/189
965/319/215
1080/335/226
Net weight
Kg
7.4
8.2
10.8
12.9
Power wiring
mm2
From outdoor
From outdoor
From outdoor
From outdoor
Communication wiring
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
KAE-26 DR8
KAE-35 DR8
KAE-52 DR7
KAE-71 DR7
OUTDOOR UNIT Compressor type
Rotary
Rotary
Rotary
Rotary
Outdoor airflow
3
m /h
2000
2000
2100
2700
Sound pressure
dB (A)
55
55
57
59
R-32
R-32
R-32
R-32
gr
700/12
800/12
1250 / 12
1600 / 24
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9(5/8")
Max. piping length
m
25
25
30
50
Pipe height difference
m
10
10
20
25
Width/Height/Depth
mm
770/555/300
770/555/300
800/554/333
845/700/320
Net weight
Kg
26.4
26.5
37
48
Refrigerant Refrigerant charge / Supplementary charge **
Power wiring
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Communication wiring
mm
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
2 2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
40 40
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
4.0 R-32
SCOP
50/60 Hz
24ºC
!
!
1W
24ºC
GENERAL CHARACTERISTICS AUREA II, the medium-category range of KAYSUN. The AUREA II is characterised by its polyvalent nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies. • Easy installation optional WIFI control adding K03 WIFI USB
• Drainage pipe connection from left or right option.
• MULTISYSTEM compatible unit
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• White translucent smart DISPLAY with information on the equipment and alarm systems status. • Display and comfort.
buzzer
switch-off
to
improve
ambient
• Self-locking option for Heating-Only function. • Leakage detection system.
• KID-02 S controller included to control unit's work parameters and change its configuration. • Louvers position storage.
+ +
OPTIONAL WIFI
WIFI NETWORK CONTROL (OPTIONAL)
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION
ErP
KID-02 S STANDARD
K03 WIFI USB ACCESSORY
SINGLE
For further information, please see our Controllers range
BMS AND SOFTWARE
K01-WIFI
41 41
RESIDENTIAL PRODUCT RANGE CASSETTE
AUREA II R-410A TECHNICAL SPECIFICATIONS SET
KAY-S 26 DN8
KAY-S 35 DN8
KAY-S 52 DN8
KAY-S 71 DN8
Cooling capacity (min./rated/max.)
kW
1.23/2.64/3.31
1.38/3.52/4.51
1.90/5.28/6.13
2.67/7.03/7.88
Cooling capacity (min./rated/max.)
Kcal/h
1058/2268/2848
1187/3027/3879
1638/4536/5267
2293/6048/6779
W
90/750/1270
100/1088/1740
150/1643/2350
230/2261/3110
SEER
7.4
6.5
6.4
6.3
Cooling energy class
A++
A++
A++
A++
Cold input capacity (min./rated/max.)
Cooling capacity (min./rated/max.)
kW
0.91/2.93/3.75
1.08/3.81/4.92
1.43/5.57/6.74
2.20/7.91/9.29
Cooling capacity (min./rated/max.)
Kcal/h
783/2520/3225
929/3277/4231
1227/4788/5796
1892/6803/7989
W
140/770/1340
170/1025/1760
230/1542/2400
320/2320/3320
SCOP
4.1
4.0
4.1
4.0
Cooling energy class
A+
A+
A+
A+
SCOP (warm areas)
5.4
5.2
5.5
5.2
A+++
A+++
A+++
A+++
2.12
2.30
3.89
4.95
2.88
2.79
2.78
2.48
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KAY-S 26 DR8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
Heat input capacity (min./rated/max.)
Heating energy class (warm areas) Heating capacity -7ºC
kW
COP -7ºC Power supply
V / F / Hz
INDOOR UNIT Airflow
m3/h
521/429/259
539/478/294
750/505/420
1050/750/560
Sound pressure (Silence)
dB (A)
20
21
21
26
Width/Height/Depth
mm
722/290/187
802/297/189
965/319/215
1080/335/226
Net weight
Kg
7.4
8.2
10.8
12.9
Power wiring
mm
From outdoor
From outdoor
From outdoor
From outdoor
Communication wiring
mm
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
OUTDOOR UNIT
KAE-26 DN7
KAE-35 DN7
KAE-52 DN7.1
KAE-71 DN7
Compressor type
Rotary
Rotary
Rotary
Rotary
2 2
Outdoor airflow
m3/h
1900
2000
2200
2700
Sound pressure
dB (A)
55
53
55
60
R-410A
R-410A
R-410A
R-410A
gr
800/15
950/15
1350/15
2000/30
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9 (5/8")
Max. piping length
m
25
25
30
50
Pipe height difference
m
10
10
20
25
Width/Height/Depth
mm
770/555/300
800/554/333
800/554/333
845/702/363
Net weight
Kg
Refrigerant Refrigerant charge / Supplementary charge **
Power wiring
mm
2
Communication wiring
mm
2
26.6
29.1
35.1
48.4
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
42 42
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
4.0 R-410A
SCOP
50/60 Hz
24ºC
!
!
1W
24ºC
GENERAL CHARACTERISTICS AUREA II, the medium-category range of KAYSUN. The AUREA II is characterised by its polyvalent nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies. • Easy installation optional WIFI control adding K03 WIFI USB
• Drainage pipe connection from left or right option.
• MULTISYSTEM compatible unit
• SCOP 4.0, over European Directive ERP, for a high energy efficiency.
• White translucent smart DISPLAY with information on the equipment and alarm systems status. • Display and comfort.
buzzer
switch-off
to
improve
ambient
• Self-locking option for Heating-Only function. • Leakage detection system.
• KID-02 S controller included to control unit's work parameters and change its configuration. • Louvers position storage.
+ +
OPTIONAL WIFI
WIFI NETWORK CONTROL (OPTIONAL)
POSSIBILITY TO BLOCK THE UNIT FOR HEATING-ONLY FUNCTION
ErP
KID-02 S STANDARD
K03 WIFI USB ACCESSORY
SINGLE
For further information, please see our Controllers range
BMS AND SOFTWARE
K01-WIFI
43 43
RESIDENTIAL PRODUCT RANGE CASSETTE
ONNIX TECHNICAL SPECIFICATIONS SET
KAY-D 26 DN7
KAY-D 35 DN7
KAY-D 52 DN7
Cooling capacity (min./rated/max.)
kW
1.23/2.64/3.30
1.33/3.52/4.47
1.83/5.28/6.12
Cooling capacity (min./rated/max.)
Kcal/h
1057/2270/2838
1144/3027/3844
1574/4541/5263
W
100/712/1260
100/1095/1710
140/1643/2345
SEER
6.8
6.7
6.6
Cooling energy class
A++
A++
A++
Cold input capacity (min./rated/max.)
Cooling capacity (min./rated/max.)
kW
0.85/2.93/3.72
1.04/3.81/4.88
1.40/5.57/6.74
Cooling capacity (min./rated/max.)
Kcal/h
731/2520/3199
894/3276/4197
1204/4790/5796
W
130/792/1320
160/1117/1730
200/1586/2410
SCOP
4.1
4.1
4.0
Heating efficiency class
A+
A+
A+
SCOP (warm areas)
5.3
5.2
5.1
A+++
A+++
A+++
2.31
2.43
3.75
2.76
2.81
2.82
220-240/1/50
220-240/1/50
220-240/1/50
Heat input capacity (min./rated/max.)
Heating energy class (warm areas) Heating capacity -7ºC
kW
COP -7ºC Power supply
V / F / Hz
INDOOR UNIT
KAY-D 26 DN7
KAY-D 35 DN7
KAY-D 52 DN7
Air flow
3
m /h
400/300/240
500/350/270
740/620/480
Sound pressure (Silence)
dB (A)
20
21
21
Width/Height/Depth
mm
897/312/182
897/312/182
1004/350/205
Net weight
Kg
9.5
9.9
13.5
Power wiring
mm
From outdoor
From outdoor
From outdoor
Communication wiring
mm
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
OUTDOOR UNIT
KAE-26 DN7
KAE-35 DN7
KAE-52 DN7.1
Compressor type
Rotary
Rotary
Rotary
2 2
Outdoor airflow
m3/h
1900
2000
2200
Sound pressure
dB (A)
55
56
55
R-410A
R-410A
R-410A
gr
800/15
950/15
1350/15
Liquid pipe diameter
mm (Inch)
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
Ø12.7 (1/2")
Max. piping length
m
25
25
30
Pipe height difference
m
10
10
20
Width/Height/Depth
mm
770/550/300
800/554/333
800/554/333
Net weight
Kg
Refrigerant Refrigerant charge / Supplementary charge **
Power wiring
mm
2
Communication wiring
mm
2
26.6
29.1
35.1
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 30ºC (Heating)
44 44
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
4.0 R-410A
50/60
SCOP
Hz
1W
!
!
GENERAL CHARACTERISTICS Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow and it closes when it switches off to recover its compact appearance.
•
White translucent smart DISPLAY with information on the equipment and alarm systems status.
•
A brightness sensor regulates the display's intensity.
•
KID-02 S controller included to control unit's work parameters and change its configuration.
•
Louvers position storage.
•
Optional WIFI control adding K03 WIFI USB.
•
Drainage pipe connection from left or right option.
•
SCOP 4.0, over European Directive ERP, for a high energy
efficiency. •
Self-locking option for Heating-Only function.
•
Leakage detection system.
•
MULTISYSTEM compatible unit
+ +
WIFI NETWORK CONTROL (OPTIONAL)
BRIGHTNESS SENSOR
ErP ErP
OPTIONAL WIFI
K03 WIFI USB ACCESSORY
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers range
INDIVIDUAL
KID-02 S
KID-02 S STANDARD
BMS AND SOFTWARE
KCT-02.1 SR
KC-01 S
KC-02.1 H
K01-WIFI
45 45
RESIDENTIAL PRODUCT RANGE CASSETTE
DOUBLE FLOW CONSOLE TECHNICAL SPECIFICATIONS KSD-35 DVN11
SET Cooling capacity (min./rated/max.)
kW
0.77/3.52/3.81
Cooling capacity (min./rated/max.)
Kcal/h
662/3027/3277
W
174/1170/1844
Cold input capacity (min./rated/max.) SEER
6.1
Cooling energy class
A++
Cooling capacity (min./rated/max.)
kW
0.46/3.81/4.34
Cooling capacity (min./rated/max.)
Kcal/h
396/3277/3732
W
149/1100/1465
Heat input capacity (min./rated/max.) SCOP
4.0
Heating efficiency class
A+
SCOP (warm areas)
5.1
Heating energy class (warm areas) Heating capacity -7ºC
A+++
kW
COP -7ºC Power supply
3.15 2.69
V / F / Hz
220-240/1/50
KSD-35 DR11
INDOOR UNIT Air flow
3
m /h
512/480/370
Sound pressure (low speed)
dB (A)
35
Width/Height/Depth
mm
700/600/210
Net weight
Kg
14.8
Power wiring
mm
2
Communication wiring
mm
2
From outdoor (3+T)x2.5
KUE-35 DVN11
OUTDOOR UNIT Compressor type
Rotary
Outdoor airflow
3
m /h
2000
Sound pressure
dB (A)
56
Refrigerant Refrigerant charge / Supplementary charge **
R-410A
gr
1050 / 15
Liquid pipe diameter
mm (Inch)
Ø6.35 (1/4")
Gas pipe diameter
mm (Inch)
Ø9.52 (3/8")
Max. piping length
m
25
Pipe height difference
m
10
Width/Height/Depth
mm
800/554/333
Net weight
Kg
29.9
Power wiring
mm2
(2+T)x2.5
Communication wiring
mm2
(3+T)x2.5
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
46 46
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
4.0 R-410A
SCOP
!
GENERAL CHARACTERISTICS The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. It is fitted with the latest technological features, thereby providing users with a high comfort level. •
Double air supply
•
DC Inverter fan motor with 5 speeds.
•
Four air intakes
•
Voltage-free alarm and ON/OFF dry contacts.
•
Silent unit
•
Optional wired controller.
ErP
KID-02 S (*) RECOMMENDED
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers range
INDIVIDUAL
KID-02 S
CHOOSE YOUR
CONTROLLER
BMS AND SOFTWARE
KCT-02.1 SR
KC-01 S
KC-02.1 H
K01-WIFI
47 47
RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
MULTISYSTEM SUITE RESIDENTIAL PRODUCT RANGE
“ELEGANCE
Introducing the KAYSUN Multisystem DC Inverter designed to provide comfort and technology to every space. Available in R-410A and R-32. This is a flexible and versatile range that allows multiple combinations with different types of interior units. This range is also affected by the European Directive ERP regarding equipment of less than 8 kW, with which is compliant thanks to the technological development of its components. The whole range is fitted with fans and DC Inverters compressors. These units are the solution for small spaces in which a larger scale installation is not possible. They allow for combinations containing up to 5 indoor units.
AND COMFORT FOR YOUR HOME” The Multisystem range increases the number of indoor units compatible with both R-410A and R-32 refrigerants. In 2018, the R-32 Multisystem range offers a wider ream of possibilities.
OUTDOOR UNITS The residential product range has external units with a robust design designed to make maintenance easier and to protect its main components, so as to extend the useful life of the product.
R-410A
+
STRONG
+
LOW SOUND LEVELS
ErP
APP/WIFI KAYSUN has a plug&play WiFi control system. Thanks to our USB accessory, you can quickly and easily configure your split unit through your smartphone.
+
WEEKLY TIMER
+
CHECK
+
BASIC FUNCTIONS K03 WIFI USB ACCESSORY
DOWNLOAD OUR APPLICATION FROM:
www.kaysun.es 48 48
+
PLUG & PLAY
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DISTANCES AND HEIGHT DIFFERENCES TOTAL LENGTH
2X1
3X1
4X1
5X1
40
60
80
80
35
35
MAXIMUM HEIGHT
15
MAXIMUM DISTANCE PER OUTPUT
25
30
R-32 REFRIGERANT UNITS Last year, Frigicoll, by means of its KAYSUN brand, started marketing some of its products fitted with R-32 refrigerant. The new EU regulations encourages the use of alternative gases, such as R-32 refrigerant gas. The R-32 refrigerant has a 675 global warming potential (GWP), a very low rate if compared to the 2,088 GWP produced by R-410A refrigerant. It is more cost-efficient, 10% more suitable and reduces charge volume by 25% because it is more compact. In addition, it offers better performance at an extreme outdoor temperature and is easy to reuse and recycle, as it is made up of a single refrigerant component.
OUTDOOR UNIT
Ducts
AUREA II
DOUBLE FLOW CONSOLE
PRODIGY
CASSETTE
49 49
RESIDENTIAL PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
R-410A
R-410A MULTISYSTEM POWER KW
2.0
2.6
3.5
5.2
7.1
KAY-26 DR8
KAY-35 DR8
KAY-52 DR8
KAY-71 DR8
KAY-S 26 DR8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
KAY-D 26 DN7
KAY-D 35 DN7
KAY-D 52 DN7
INDOOR UNITS PRODIGY
AUREA II
ONNIX
(Page 56)
(Page 58)
(Page 60)
DOUBLE FLOW CONSOLE
(Page 62) KSD-35 DR11
CASSETTE
Ducts
(Page 64) KCI-26 DMR11
KCI-35 DR11
KPD-35 DR11*
KPD-35 DR11
KCI-52 DMR11
(Page 66)
KPD-35 DR11*
*The KPD-35 DR11 unit can be configured for 2kW and 2.6kW
4.2
POWER KW
OUTDOOR UNITS
R-410A
5.2
6.2
7.8
10.5
12.0
(Page 52)
Nยบ OF INDOOR UNITS
2 3
KAM2-42 DN8
KAM2-52 DN7 KAM3-62 DN7
KAM3-78 DN7
4 5 Note: The SUITE MULTISYSTEM range is currently in the process of obtaining the EUROVENT Certification.
50 50
8.0
KAM4-80 DN7
KAM4-105 DN7 KAM5-120 DN7
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
R-32 MULTISYSTEM POWER KW
2.0
2.6
3.5
5.2
7.1
INDOOR UNITS PRODIGY
AUREA II
NEW
(Page 56) KAY-26 DR8
KAY-35 DR8
KAY-52 DR8
KAY-71 DR8
KAY-S 26 DR8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
(Page 58)
DOUBLE FLOW CONSOLE
NEW
(Page 62)
KSD-35 DR11
CASSETTE
NEW
(Page 64) KCI-26 DMR11
Ducts
NEW
KPD-35 DR11*
KCI-35 DR11
KCI-52 DMR11
(Page 66) KPD-35 DR11*
KPD-35 DR11
*The KPD-35 DR11 unit can be configured for 2kW and 2.6kW
4.2
POWER KW
OUTDOOR UNITS
5.2
6.2
7.8
8.0
10.5
12.0
(Page 54)
Nยบ OF INDOOR UNITS
2 3 4 5
KAM2-52 DR7 KAM3-78 DR7 KAM4-105 DR7 KAM5-120 DR7
51 51
RESIDENTIAL PRODUCT RANGE OUTDOOR UNIT
OUTDOOR UNITS
R-410A MULTISYSTEM
KAYSUN MULTISYSTEM outdoor units, with their new appearance and stronger structure, provide greater output with less noise pollution.
+ +
STRONG
QUIET
ErP
TECHNICAL SPECIFICATIONS MODEL
KAM2-42 DN8
KAM2-52 DN7
Cooling capacity
kW
4.10
5.28
6.15
Cooling capacity
Kcal/h
3526
4536
5292
Cooling input
kW
1.25
1.60
1.91
Heating Capacity
kW
4.40
5.57
6.59
Heating Capacity
Kcal/h
3784
4788
5670
Heating input
kW
1.15
1.59
1.78
Power supply
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Rotary
Rotary
Rotary
2100
2100
2700
Compressor type Outdoor airflow
m3/h
Sound pressure
dB (A)
Refrigerant
54
56.5
57.5
R-410A
R-410A
R-410A
Additional refrigerant charge*
gr
1250
1700
2100
Pre-charge metres*
m
10
10
15
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4") x 2
ø6.35 (1/4") x 2
ø6.35 (1/4") x 3
Gas pipe diameter
mm (Inch)
ø9.52 (3/8") x 2
ø9.52 (3/8") x 2
ø9.52 (3/8") x 3
Piping max. length
m
40
40
60
Piping max. length (1 indoor unit)
m
25
25
30
Height difference between indoor and outdoor units
m
15
15
15
Height difference between indoor units
m
10
10
10
Width/Height/Depth
mm
800/554/333
800/554/333
845/702/363
Net weight
Kg
31.5
36
47.0
2
2
3
Maximum number of indoor units Power wiring
2
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Communication wiring
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating) *To calculate the additional load necessary for these units, we applied the following formula: ADDITIONAL LOAD (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE OF ¼” x 15 Grams). (TOTAL LENGTH OF LIQUID LINE OF 3/8” x 30 Grams) - (TOTAL LENGTH OF FACTORY PRELOAD x 15 Grams) Note 1: Standard performance data; definitive performance data depend on the combination of indoor units. Note 2: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. 52
KAM3-62 DN7
52 52
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC R-410A
KAM3-78 DN7
INVERTER
KAM4-80 DN7
KAM4-105 DN7
7.91
8.21
10.55
12.31
6804
7056
9072
10584
!
DC
INVERTER
OUTDOOR
KAM5-120 DN7
2.46
2.55
3.62
3.82
8.21
8.79
11.14
12.60
7056
7560
9576
10836
2.27
2.43
3.17
3.31
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Rotary
Rotary
Rotary
Rotary
3500
3800
5500
5500
59.5
60
63.5
62
R-410A
R-410A
R-410A
R-410A
2100
2400
3000
3600
15
20
20
25
ø6.35 (1/4") x 3
ø6.35 (1/4") x 4
ø6.35 (1/4") x 4
ø6.35 (1/4") x 5
ø9.52 (3/8") x 3
ø9.52 (3/8”) x 3 + ø12.7 (1/2”) x 1
ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1
ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2
60
80
80
80
30
35
35
35
15
15
15
15
10
10
10
10
845/702/363
946/810/410
946/810/410
946/810/410
52.7
67.6
70.0
76.0
3
4
4
5
(2+T)x4
(2+T)x4
(2+T)x6
(2+T)x6
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
53 53
RESIDENTIAL PRODUCT RANGE OUTDOOR UNIT
OUTDOOR UNITS
R-32 MULTISYSTEM
TECHNICAL SPECIFICATIONS MODEL
KAM2-52 DR7
KAM3-78 DR7
KAM4-105 DR7 KAM5-120 DR7
Cooling capacity
kW
5.28
7.91
10.55
12.31
Cooling capacity
Kcal/h
4536
6804
9072
10584
Cooling input
kW
7.75
2.47
3.52
3.80
Heating Capacity
kW
5.57
8.21
11.40
12.60
Heating Capacity
Kcal/h
4788
7056
9576
10836
Heating input
kW
1.45
2.25
2.88
3.30
Power supply
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Rotary
Rotary
Rotary
Rotary
Compressor type Outdoor airflow
m3/h
2200
2700
4000
3850
Sound pressure
dB (A)
56
59
63
62
R-32
R-32
R-32
R-32
Refrigerant Additional refrigerant charge*
gr
1300
1570
2100
2400
Pre-charge metres*
m
15
22.5
30
37.5
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4") x 2
ø6.35 (1/4") x 3
ø6.35 (1/4") x 4
ø6.35 (1/4") x 5
Gas pipe diameter
mm (Inch)
ø9.52 (3/8") x 2
ø9.52 (3/8") x 3
ø9.52 (3/8") x 3 + ø12.7 (1/2") x 1
ø9.52 (3/8") x 3 + ø12.7 (1/2") x 2
Max. piping length
m
40
60
80
80
Piping max. length (1 indoor unit)
m
25
30
35
35
Height difference between indoor and outdoor units
m
15
15
15
15
Height difference between indoor units
m
10
10
10
10
Width/Height/Depth
mm
800/554/333
845/702/363
946/810/410
946/810/410
Net weight
Kg
36.0
53.0
68.8
73.3
2
3
4
5
Maximum number of indoor units Power wiring
mm2
(2+T)x2.5
(2+T)x4
(2+T)x6
(2+T)x6
Communication wiring
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
*To calculate the additional load necessary for these units, we applied the following formula: ADDITIONAL LOAD (GR) = (TOTAL LENGTH OF ALL CIRCUITS' LIQUID LINE OF ¼” x 12 Grams). (TOTAL LENGTH OF LIQUID LINE OF 3/8” x 24 Grams) - (TOTAL LENGTH OF FACTORY PRELOAD x 12 Grams) Note 1: Standard performance data; definitive performance data depend on the combination of indoor units. Note 2: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
54 54
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
INVERTER
R-32
!
DC
INVERTER
OUTDOOR
KAYSUN MULTISYSTEM outdoor units, with their strong structure, provide greater output with less noise pollution.
+ +
STRONG
QUIET
ErP
55 55
RESIDENTIAL PRODUCT RANGE INDOOR UNIT
PRODIGY MULTI TYPE TECHNICAL SPECIFICATIONS MODEL
KAY-26 DR8
KAY-35 DR8
KAY-52 DR8
KAY-71 DR8
Cooling capacity
kW
2.63
3.51
5.27
7.3
Cooling capacity
Kcal/h
2262
3019
4532
6278
Heating Capacity
kW
2.93
4.1
5.56
7.61
Heating Capacity
Kcal/h
2520
3526
4781
6545
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Air flow
m³/h
486/433/329
550/490/360
810/720/550
1050/970/650
Sound pressure (Silence)
dB (A)
22
23
24
27
Inlet liquid pipe liquid
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9(5/8")
Width/Height/Depth
mm
717/302/193
805/302/193
964/325/222
1106/342/232
Net weight
Kg
7.5
8.2
10.8
14.3
Power wiring
mm2
From outdoor
From outdoor
From outdoor
From outdoor
Communication wiring
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
Power supply
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
56 56
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
24ºC
INDOOR
24ºC
INVERTER
R-32
R-410A
GENERAL CHARACTERISTICS PRODIGY, is the new KAYSUN wall unit. It represents a revolution in installation and preventive maintenance*. Easy installation and maintenance and fitted with Kaysun avant-garde technology. • KID-02 S controller included to control unit's work parameters and change its configuration.
• Optional WIFI control adding K03 WIFI USB. • Compatible with 1x1 systems. • White translucent smart DISPLAY with information on the equipment and alarm systems status. • The display and buzzer have a switch-off option that can be activated if they annoy the user.
+ +
• Louvers position storage. • Drainage pipe connection from left or right option. • Compatible with wired controllers.
WIFI NETWORK CONTROL (OPTIONAL)
EASY ASSEMBLY AND MAINTENANCE
ErP
KID-02 S STANDARD
COMPATIBLE WITH K03 WIFI USB ACCESSORY
MULTISYSTEM OUTDOOR UNITS
OPTIONAL WIFI
see pag. 52 for R-410A see pag. 54 for R-32
* For further information, please check the Presentation section of this manual.
SINGLE
For further information, please see our Controllers range
INDIVIDUAL
KC-01 S
BMS AND SOFTWARE
KC-02.1 H
KCT-02.1 SR
K01-WIFI
57 57
RESIDENTIAL PRODUCT RANGE INDOOR UNIT
AUREA II
MULTI TYPE
TECHNICAL SPECIFICATIONS MODEL
KAY-S 26 DR8
KAY-S 35 DR8
KAY-S 52 DR8
KAY-S 71 DR8
Cooling capacity
kW
2.69
3.51
5.27
7.3
Cooling capacity
Kcal/h
2313
3019
4532
6278
Heating capacity
kW
2.93
3.81
5.57
7.64
Heating capacity
Kcal/h
2520
3276
4788
6552
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Airflow
m3/h
521/429/259
539/478/294
750/505/420
1050/750/560
Sound pressure (Silence)
dB (A)
20
21
23
26
Width/Height/Depth
mm
722/290/187
802/297/189
965/319/215
1080/335/226
Net weight
Kg
7.4
8.2
9
12
Power supply
Power wiring
mm2
From outdoor
From outdoor
From outdoor
From outdoor
Communication wiring
mm
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
58 58
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
24ºC
INVERTER
R-32
R-410A
24ºC
INDOOR
GENERAL CHARACTERISTICS AUREA II, the medium-category range of KAYSUN. The AUREA II is characterised by its polyvalent nature: it can run on R-410A or R-32 refrigerant. In addition to a simple and elegant design, it incorporates all of KAYSUN’s most advanced characteristics and technologies. • Optional WIFI control adding K03 WIFI USB.
and change its configuration.
• Compatible with 1x1 systems.
• Louvers position storage.
• White translucent smart DISPLAY with information on the equipment and alarm systems status.
• Drainage pipe connection from left or right option.
• The display and buzzer have a switch-off option that can be activated if they annoy the user. • KID-02 S controller included to control unit's work parameters
+ +
20 dB SOUND PRESSURE
WIFI NETWORK CONTROL (OPTIONAL)
KID-02 S ErP
STANDARD
COMPATIBLE WITH K03 WIFI USB ACCESSORY OPTIONAL WIFI
MULTISYSTEM OUTDOOR UNITS see pag. 52 for R-410A see pag. 54 for R-32
SINGLE BMS AND SOFTWARE
K01-WIFI
59 59
RESIDENTIAL PRODUCT RANGE INDOOR UNIT
ONNIX
MULTI TYPE
TECHNICAL SPECIFICATIONS MODEL
KAY-D 26 DN7
KAY-D 35 DN7
KAY-D 52 DN7
Cooling capacity
kW
2.64
3.52
5.28
Cooling capacity
Kcal/h
2268
3024
4536
Heating Capacity
kW
2.93
3.81
5.57
Heating Capacity
Kcal/h
2520
3276
4788
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Air flow
m3/h
400/300/240
500/350/270
740/620/480
Sound pressure (Silence)
dB (A)
20
21
21
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
Width/Height/Depth
mm
897/182/312
897/182/312
1004/205/350
Net weight
Kg
9.5
9.9
13.5
Power wiring
mm2
From outdoor
From outdoor
From outdoor
Communication wiring
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
Power supply
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
60 60
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
INVERTER
R-410A
INDOOR
GENERAL CHARACTERISTICS Onnix, the top-end range of KAYSUN in wall-mounted units. Its original V-shape design, dark shade finishing and mirror-effect front side provide this unit with a very attractive modern appearance. The unit opens automatically when it switches on to increase airflow and it closes when it switches off to recover its compact appearance. • A brightness sensor regulates the display's intensity.
• Compatible with 1x1 systems and multisystems.
• KID-02 S controller included to control unit's work parameters and change its configuration.
• Drainage pipe connection from left or right option.
• Louvers position storage. • Optional WIFI control adding K03 WIFI USB.
+ +
20 dB SOUND PRESSURE
WIFI NETWORK CONTROL (OPTIONAL)
ErP
KID-02 S STANDARD
COMPATIBLE WITH K03 WIFI USB ACCESSORY
MULTISYSTEM OUTDOOR UNITS
OPTIONAL WIFI
see pag. 52 for R-410A
SINGLE
For further information, please see our Controllers range
INDIVIDUAL
KC-01 S
BMS AND SOFTWARE
KC-02.1 H
KCT-02.1 SR
K01-WIFI
61 61
RESIDENTIAL PRODUCT RANGE INDOOR UNIT
DOUBLE FLOW CONSOLE
MULTI TYPE
TECHNICAL SPECIFICATIONS KSD-35 DR11
MODEL Cooling capacity
kW
3.46
Cooling capacity
Kcal/h
2976
Heating Capacity
kW
3.75
Heating Capacity
Kcal/h
2976
V / F / Hz
220-240/1/50
Air flow
m³/h
516/480/370
Sound pressure (low speed)
dB (A)
35
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
Width/Height/Depth
mm
700/600/210
Net weight
Kg
15
Power wiring
mm2
From outdoor
Communication wiring
mm2
(3+T)x2.5
Power supply
*Sound pressure in “Silence” mode. Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
62
62 62
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
INVERTER
R-32
R-410A
INDOOR
GENERAL CHARACTERISTICS
The double flow console has an elegant and compact design that allows for the adaptation thereof to any area to be air-conditioned. This unit has the best technological features and its adaptability cover the needs of every user. • DC INVERTER FAN MOTOR.
• Easy installation.
• Double air supply and four air intakes.
• Optional wired controller.
• Voltage-free alarm and ON/OFF dry contacts.
+
KID-02 S
DOUBLE AIR INTAKE
ErP
STANDARD
COMPATIBLE WITH
MULTISYSTEM OUTDOOR UNITS see pag. 52 for R-410A see pag. 54 for R-32
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers range
INDIVIDUAL
KID-02 S
CHOOSE YOUR
CONTROLLER
BMS AND SOFTWARE
KCT-02.1 SR
KC-01 S
KC-02.1 H
K01-WIFI
63 63
RESIDENTIAL PRODUCT RANGE INDOOR UNIT
CASSETTE
MULTI TYPE
TECHNICAL SPECIFICATIONS MODEL
KCI-26 DMR11
KCI-35 DR11
KCI-52 DMR11
Cooling capacity
kW
2.64
3.52
4.98
Cooling capacity
Kcal/h
2268
3024
4284
Heating Capacity
kW
2.93
4.1
5.57
Heating Capacity
Kcal/h
2520
3528
4788
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Air flow
3
m /h
580/500/450
617/504/416
680/560/500
Sound pressure (low speed)
dB (A)
29
35
41
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
Width/Height/Depth
mm
570/260/570
570/260/570
570/260/570
Net weight
Kg
14.7
16
16.1
Panel width/height/depth
mm
647/50/647
647/50/647
647/50/647
Panel net weight
Kg
2.5
2.5
2.5
Power wiring
mm2
From outdoor
From outdoor
From outdoor
Communication wiring
mm2
(3+T)x2.5
(3+T)x2.5
(3+T)x2.5
Power supply
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
64
64 64
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
INVERTER
R-32
R-410A
INDOOR
GENERAL CHARACTERISTICS
The Cassette units have an impeccable design. Its 360º airflow provides user with maximum comfort covering every single corner of the room. • They are fitted with an up to 500 mm high standard condensation pump.
• The Cassette 600x600 type units supply 10 % to 15 % of outdoor airflow directly to the unit return system.
• Voltage-free alarm and ON/OFF dry contacts.
• The electric box is located at the lower side of the unit to get a more compact size and embed the unit easily in the ceiling.
• The right and left sides of these units' body are designed to connect the necessary piping to air-condition an adjacent room.
+
OUTDOOR AIR SUPPLY (10-15%)
+
500mm CONDENSATION PUMP
KID-02 S RECOMMENDED ErP
COMPATIBLE WITH NEW
MULTISYSTEM OUTDOOR UNITS
OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
see pag. 52 for R-410A see pag. 54 for R-32
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers range
INDIVIDUAL
CENTRALISED NEW
KID-02 S
CHOOSE YOUR
CONTROLLER
KCT-02.1 SR
KC-02.1 H
KCCT-64 I (B)
KC-01 S
KCCT-64 IPS
NEW
KCCT-384 IPS
KCC-64 WEB
K01-KNX
K01-WIFI
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
65 65 65
RESIDENTIAL PRODUCT RANGE INDOOR UNIT
Ducts
MULTI TYPE
NEW
TECHNICAL SPECIFICATIONS MODEL
KPD-35 DR11
Cooling capacity
kW
3.52
Cooling capacity
Kcal/h
3024
Heating Capacity
kW
3.81
Heating Capacity
Kcal/h
3276
V / F / Hz
220-240/1/50
m3/h
600/480/300
Maximum pressure available
Pa
60
Sound pressure (low speed)
dB (A)
27.5
Liquid pipe diameter
mm (Inch)
ø6.35 (1/4")
Gas pipe diameter
mm (Inch)
ø9.52 (3/8")
Width/Height/Depth
mm
975/200/450
Net weight
Kg
18
Power supply Air flow
Power wiring
mm
From outdoor
Communication wiring
mm2
(3+T)x2.5
2
CAN BE CONFIGURED FOR 2 & 2.6 kW Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases.
66
66 66
33
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
DC
INVERTER
R-32
INDOOR
R-410A
GENERAL CHARACTERISTICS The tilted evaporator of the KAYSUN Ducts provides them with a very slim design. This feature allows for installing Ducts units in areas where the false ceiling is too narrow. The KC-03.1 SPS wired controller includes a new feature that allows selecting static pressure automatically. This unit can also be installed in vertical position (floor standing). • The filter is easy to remove even when piping is in place. • All units include an air inlet/outlet pre-installation to facilitate the fitting of the tubes that guarantee air circulation. • Outdoor air intake to treat air with indoor unit's battery and blow it into the room through the air line. • The electric box of Duct type indoor units is removable up to 1 metre.
• They are fitted with an up to 500 mm high standard condensation pump. • Voltage-free alarm and ON/OFF dry contacts. • Horizontal and vertical installation. • The KC-03.1 SPS controller allows adjusting the available pressure automatically.
+ ErP
+ +
Compatible with
OUTDOOR AIR INTAKE
750mm CONDENSATION PUMP
HORIZONTAL AND VERTICAL INSTALLATION
KC-03.1 SPS RECOMMENDED
COMPATIBLE WITH NEW
MULTISYSTEM OUTDOOR UNITS
OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
see pag. 52 for R-410A see pag. 54 for R-32
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers Range
INDIVIDUAL
CENTRALISED NEW
KID-02 S
CHOOSE YOUR
CONTROLLER
KCT-02.1 SR
KC-03 SPS
KC-03.1 SPS
KC-02.1 H
KC-01 S
KCCT-64 I (B)
KCCT-64 IPS
NEW
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
67 67 67
RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS
COMBINED SYSTEMS KAM2-42 DN8
R-410A MULTISYSTEM
x1
x2
20
20+20
26
20+26
35
20+35
52
26+26 26+35
KAM2-52 DN7
x1
x2
20
20+20
26
20+26
35
20+35
52
20+52 26+26 26+35 26+52 35+35
68 68
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
COMBINATIONS
1x2
EER (W/W)
SEER
ENERGY CLASS
UNIT A
UNIT B
20
20
2.05
2.05
1.76
4.10
4.54
0.42
1.24
1.43
3.30
6.10
A++
20
26
1.79
2.31
1.76
4.10
4.54
0.42
1.24
1.43
3.30
6.10
A++
MINIMUM
RATED
MAXIMUM
MINIMUM
RATED
MINIMUM RATED CAPACITY
20
35
1.51
2.59
1.76
4.10
4.54
0.42
1.23
1.43
3.32
6.10
A++
26
26
2.05
2.05
1.76
4.10
4.54
0.42
1.24
1.43
3.30
6.10
A++
26
35
1.76
2.34
1.76
4.10
4.54
0.42
1.23
1.43
3.32
6.10
A++
RATED CAPACITY (kW)
HEATING POWER (kW)
UNIT B
POWER INPUT (kW)
COP (W/W)
ENERGY CLASS
SCOP
COP -7
UNIT A
UNIT B
UNIT A
20
20
2.20
2.20
1.89
4.40
4.87
0.39
1.16
1.33
3.80
4.00
A+
3.15
20
26
1.93
2.48
1.89
4.40
4.87
0.39
1.16
1.33
3.80
4.00
A+
3.15
MINIMUM
RATED
MAXIMUM MINIMUM
RATED
RATED CAPACITY
MAXIMUM
20
35
1.66
2.84
1.89
4.50
4.98
0.39
1.19
1.33
3.78
4.00
A+
3.13
26
26
2.20
2.20
1.89
4.40
4.87
0.39
1.16
1.33
3.80
4.00
A+
3.15
26
35
1.93
2.57
1.89
4.50
4.98
0.39
1.19
1.33
3.78
4.00
A+
3.13
UNIT A
UNIT B
RATED CAPACITY (kW) UNIT A
UNIT B
HEATING CAPACITY (kW) MINIMUM
RATED
EER (W/W)
POWER INPUT (kW) MAXIMUM
MINIMUM
RATED
SEER
ENERGY CLASS
RATED CAPACITY
MAXIMUM
20
20
2.10
2.10
2.08
4.20
5.51
0.59
1.27
2.16
3.31
6.20
A++
20
26
2.06
2.64
2.08
4.70
5.72
0.59
1.46
2.16
3.23
6.20
A++ A++
20
35
1.95
3.35
2.08
5.30
6.29
0.59
1.82
2.16
2.91
6.10
20
52
1.51
3.92
2.08
5.40
6.34
0.59
1.77
2.16
3.05
6.10
A++
26
26
2.60
2.60
2.08
5.20
6.29
0.59
1.79
2.16
2.91
6.30
A++
26
35
2.31
3.09
2.08
5.40
6.29
0.59
1.83
2.16
2.95
6.30
A++
26
52
1.80
3.60
2.08
5.40
6.34
0.59
1.77
2.16
3.05
6.30
A++
35
35
2.70
2.70
2.08
5.40
6.29
0.59
1.79
2.16
3.01
6.30
A++
COMBINATIONS
1x2
POWER INPUT (kW)
UNIT B
COMBINATIONS
1x2
COOLING CAPACITY (kW)
UNIT A
COMBINATIONS
1x2
RATED CAPACITY (kW)
RATED CAPACITY (kW)
UNIT A
UNIT B
UNIT A
UNIT B
HEATING POWER (kW) MINIMUM
RATED
COP (W/W)
INPUT INPUT (kW) MAXIMUM MINIMUM
RATED
MAXIMUM
SCOP
ENERGY CLASS
COP -7
RATED RATED
20
20
2.50
2.50
2.20
5.00
5.94
0.50
1.30
1.85
3.85
4.00
A+
3.19
20
26
2.32
2.98
2.20
5.30
6.05
0.50
1.39
1.85
3.81
4.00
A+
3.16
20
35
2.03
3.47
2.20
5.50
6.66
0.50
1.48
1.85
3.71
4.00
A+
3.07
20
52
1.57
4.07
2.20
5.60
6.71
0.50
1.47
1.85
3.81
4.00
A+
3.16
26
26
2.75
2.75
2.20
5.50
6.66
0.50
1.48
1.85
3.71
4.00
A+
3.07
26
35
2.40
3.20
2.20
5.60
6.66
0.50
1.49
1.85
3.75
4.00
A+
3.11
26
52
1.87
3.73
2.20
5.60
6.71
0.50
1.47
1.85
3.81
4.00
A+
3.16
35
35
2.80
2.80
2.20
5.60
6.66
0.50
1.49
1.85
3.75
4.00
A+
3.11
69 69
RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS
COMBINED SYSTEMS KAM3-62 DN7
R-410A MULTISYSTEM
x1
x2
x3
20
20+20
20+20+20
26
20+26
20+20+26
35
20+35
20+20+35
52
20+52
20+26+26
26+26
20+26+35
26+35
26+26+26
26+52
26+26+35
35+35
KAM3-78 DN7
x1
x2
x3
20
20+20
20+20+20
26
20+26
20+20+26
35
20+35
20+20+35
52
20+52
20+20+52
26+26
20+26+26
26+35
20+26+35
26+52
20+26+52
35+35
20+35+35
35+52
26+26+26 26+26+35 26+35+35 35+35+35
70 70
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
RATED CAPACITY (kW)
COMBINATIONS
ENERGY CLASS
UNIT B
UNIT C
20
20
20
2.03
2.03
2.03
2.44
6.10
7.20
0.68
1.90
2.38
3.21
6.10
20
20
26
1.92
1.92
2.47
2.44
6.30
7.26
0.68
1.96
2.38
3.22
6.10
A++
20
20
35
1.70
1.70
2.91
2.44
6.30
7.32
0.68
1.94
2.38
3.24
6.10
A++
20
26
26
1.76
2.27
2.27
2.44
6.30
7.32
0.68
1.94
2.38
3.24
6.10
A++
20
26
35
1.58
2.03
2.70
2.44
6.30
7.32
0.68
1.94
2.38
3.24
6.10
A++
26
26
26
2.10
2.10
2.10
2.44
6.30
7.32
0.68
1.94
2.38
3.24
6.10
A++
26
26
35
1.89
1.89
2.52
2.44
6.30
7.32
0.68
1.94
2.38
3.24
6.10
A++
MINIMUM
RATED CAPACITY (kW)
UNIT B
UNIT C
UNIT A
UNIT B
MAXIMUM MINIMUM
HEATING POWER (kW)
POWER INPUT (kW)
RATED
RATED
UNIT C MINIMUM
MAXIMUM MINIMUM
MAXIMUM RATED CAPACITY
COP (W/W)
SCOP
A++
ENERGY CLASS
COP -7
RATED CAPACITY
MAXIMUM
20
20
20
2.20
2.20
2.20
2.64
6.60
7.79
0.64
1.78
2.22
3.71
4.00
A+
2.90
20
20
26
2.02
2.02
2.60
2.64
6.65
7.79
0.64
1.79
2.22
3.71
4.00
A+
2.90
20
20
35
1.80
1.80
3.09
2.64
6.70
7.92
0.64
1.81
2.22
3.71
4.00
A+
2.95
20
26
26
1.88
2.41
2.41
2.64
6.70
7.92
0.64
1.81
2.22
3.71
4.00
A+
2.95
20
26
35
1.68
2.15
2.87
2.64
6.70
7.92
0.64
1.81
2.22
3.71
4.00
A+
2.95
26
26
26
2.23
2.23
2.23
2.64
6.70
7.92
0.64
1.81
2.22
3.71
4.00
A+
2.95
26
26
35
2.01
2.01
2.68
2.64
6.70
7.92
0.64
1.81
2.22
3.71
4.00
A+
2.95
RATED CAPACITY (kW)
COMBINATIONS UNIT A
UNIT B
UNIT C
UNIT A
UNIT B
UNIT C
MINIMUM
HEATING CAPACITY (kW)
POWER INPUT (kW)
RATED
RATED
MAXIMUM MINIMUM
EER (W/W)
SEER
ENERGY CLASS
MAXIMUM RATED CAPACITY
20
20
20
2.43
2.43
2.43
2.77
7.30
8.69
0.76
2.27
2.93
3.21
6.60
A++
20
20
26
2.25
2.25
2.90
2.77
7.40
8.69
0.76
2.31
2.93
3.21
6.60
A++
20
20
35
2.13
2.13
3.65
2.77
7.90
8.69
0.76
2.46
2.93
3.21
6.60
A++
20
20
52
1.73
1.73
4.44
2.77
7.90
8.69
0.76
2.44
2.93
3.24
6.60
A++
20
26
26
2.13
2.74
2.74
2.77
7.60
8.69
0.76
2.37
2.93
3.21
6.60
A++
20
26
35
1.98
2.54
3.39
2.77
7.90
8.69
0.76
2.46
2.93
3.21
6.60
A++
20
26
52
1.63
2.09
4.18
2.77
7.90
8.69
0.76
2.44
2.93
3.24
6.60
A++
20
35
35
1.78
3.06
3.06
2.77
7.90
8.69
0.76
2.45
2.93
3.23
6.60
A++ A++
26
26
26
2.63
2.63
2.63
2.77
7.90
8.69
0.76
2.46
2.93
3.21
6.60
26
26
35
2.37
2.37
3.16
2.77
7.90
8.69
0.76
2.45
2.93
3.23
6.60
A++
26
35
35
2.15
2.87
2.87
2.77
7.90
8.69
0.76
2.44
2.93
3.24
6.60
A++
35
35
35
2.63
2.63
2.63
2.77
7.90
8.69
0.76
2.44
2.93
3.24
6.60
A++
RATED CAPACITY (kW)
COMBINATIONS UNIT A
1x3
RATED
SEER
UNIT A
UNIT A
1x3
RATED
EER (W/W)
UNIT C
COMBINATIONS
1x3
INPUT INPUT (kW)
UNIT B
UNIT A
1x3
HEATING CAPACITY (kW)
UNIT C MINIMUM
HEATING POWER (kW)
INPUT INPUT (kW)
RATED
RATED
MAXIMUM MINIMUM
COP (W/W) MAXIMUM
SCOP
ENERGY CLASS
COP -7
RATED CAPACITY
UNIT B
UNIT C
UNIT A
UNIT B
20
20
20
2.27
2.27
2.27
2.87
6.80
9.02
0.70
1.88
2.70
3.61
4.00
A+
2.99
20
20
26
2.13
2.13
2.74
2.87
7.00
9.02
0.70
1.94
2.70
3.61
4.00
A+
2.99
20
20
35
2.13
2.13
3.65
2.87
7.90
9.02
0.70
2.19
2.70
3.61
4.00
A+
2.99
20
20
52
1.82
1.82
4.67
2.87
8.30
9.02
0.70
2.27
2.70
3.65
4.00
A+
3.02
20
26
26
2.21
2.84
2.84
2.87
7.90
9.02
0.70
2.19
2.70
3.61
4.00
A+
2.99
20
26
35
2.05
2.64
3.51
2.87
8.20
9.02
0.70
2.27
2.70
3.61
4.00
A+
2.99
20
26
52
1.71
2.20
4.39
2.87
8.30
9.02
0.70
2.27
2.70
3.65
4.00
A+
3.02
20
35
35
1.87
3.21
3.21
2.87
8.30
9.02
0.70
2.29
2.70
3.62
4.00
A+
3.00
26
26
26
2.73
2.73
2.73
2.87
8.20
9.02
0.70
2.27
2.70
3.61
4.00
A+
2.99
26
26
35
2.49
2.49
3.32
2.87
8.30
9.02
0.70
2.29
2.70
3.62
4.00
A+
3.00
26
35
35
2.26
3.02
3.02
2.87
8.30
9.02
0.70
2.27
2.70
3.65
4.00
A+
3.02
35
35
35
2.77
2.77
2.77
2.87
8.30
9.02
0.70
2.27
2.70
3.65
4.00
A+
3.02
71 71
RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS
COMBINED SYSTEMS KAM4-80 DN7
R-410A MULTISYSTEM
x1
x2
20
20+20
20+20+20
20+20+20+20
26
20+26
20+20+26
20+20+20+26
35
20+35
20+20+35
20+20+20+35
52
20+52
20+20+52
20+20+20+52
71
x3
20+71
20+20+71
20+20+26+26
26+26
20+26+26
20+20+26+35
26+35
20+26+35
20+20+35+35
26+52
20+26+52
20+26+26+26
26+71
20+35+35
20+26+26+35
35+35
20+35+52
20+26+35+35
35+52
26+26+26
26+26+26+26
35+71
26+26+35
26+26+26+35
52+52
26+26+52 26+35+35 26+35+52 35+35+35
72 72
x4
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
RATED CAPACITY (KW)
COMBINED SYSTEMS UNIT A
1x4
UNIT B
UNIT C
UNIT D
UNIT A
UNIT B
UNIT C
MIN.
RATED
MAX.
MIN.
RATED
MAX.
SEER
ENERGY CLASS
RATED CAPACITY
20
20
20
20
2.05
2.05
2.05
2.05
3.04
8.21
9.93
0.84
2.47
3.09
3.32
6.8
A++
20
20
20
26
1.92
1.92
1.92
2.46
3.04
8.21
9.93
0.84
2.47
3.09
3.32
6.8
A++
20
20
20
35
1.74
1.74
1.74
2.99
3.04
8.21
9.93
0.84
2.47
3.09
3.32
6.8
A++
20
20
20
52
1.47
1.47
1.47
3.79
3.04
8.21
9.93
0.84
2.50
3.09
3.28
6.8
A++
20
20
26
26
1.80
1.80
2.31
2.31
3.04
8.21
9.93
0.84
2.47
3.09
3.32
6.8
A++
20
20
26
35
1.64
1.64
2.11
2.81
3.04
8.21
9.93
0.84
2.49
3.09
3.30
6.8
A++
20
20
35
35
1.51
1.51
2.59
2.59
3.04
8.21
9.93
0.84
2.50
3.09
3.29
6.8
A++
20
26
26
26
1.69
2.17
2.17
2.17
3.04
8.21
9.93
0.84
2.48
3.09
3.31
6.8
A++
20
26
26
35
1.55
2.00
2.00
2.66
3.04
8.21
9.93
0.84
2.50
3.09
3.29
6.8
A++
20
26
35
35
1.44
1.85
2.46
2.46
3.04
8.21
9.93
0.84
2.50
3.09
3.28
6.8
A++
26
26
26
26
2.05
2.05
2.05
2.05
3.04
8.21
9.93
0.84
2.50
3.09
3.29
6.8
A++
26
26
26
35
1.89
1.89
1.89
2.53
3.04
8.21
9.93
0.84
2.50
3.09
3.28
6.8
A++
SCOP
ENERGY CLASS COP -7
RATED CAPACITY (KW)
COMBINED SYSTEMS UNIT A
1x4
UNIT D
EER W/W
POWER INPUT (kW)
COOLING CAPACITY (KW)
UNIT B
UNIT C
UNIT D
UNIT A
UNIT B
HEATING CAPACITY (KW)
UNIT C
UNIT D
MIN.
RATED
MAX.
COP W/W
INPUT INPUT (kW) MIN.
RATED
MAX.
RATED CAPACITY
20
20
20
20
2.20
2.20
2.20
2.20
3.26
8.80
10.65
0.83
2.44
3.05
3.61
4.0
A++
2.99
20
20
20
26
2.08
2.08
2.08
2.67
3.26
8.90
10.65
0.83
2.47
3.05
3.61
4.0
A++
2.99
20
20
20
35
1.91
1.91
1.91
3.27
3.26
9.00
10.65
0.83
2.49
3.05
3.61
4.0
A++
2.99
20
20
20
52
1.63
1.63
1.63
4.20
3.26
9.10
10.65
0.83
2.52
3.05
3.61
4.0
A++
2.99
20
20
26
26
1.95
1.95
2.50
2.50
3.26
8.90
10.65
0.83
2.47
3.05
3.61
4.0
A++
2.99
20
20
26
35
1.80
1.80
2.31
3.09
3.26
9.00
10.65
0.83
2.49
3.05
3.61
4.0
A++
2.99
20
20
35
35
1.68
1.68
2.87
2.87
3.26
9.10
10.65
0.83
2.52
3.05
3.61
4.0
A++
2.99
20
26
26
26
1.83
2.36
2.36
2.36
3.26
8.90
10.65
0.83
2.47
3.05
3.61
4.0
A++
2.99
20
26
26
35
1.70
2.19
2.19
2.92
3.26
9.00
10.65
0.83
2.49
3.05
3.61
4.0
A++
2.99
20
26
35
35
1.59
2.05
2.73
2.73
3.26
9.10
10.65
0.83
2.52
3.05
3.61
4.0
A++
2.99
26
26
26
26
2.23
2.23
2.23
2.23
3.26
8.90
10.65
0.83
2.47
3.05
3.61
4.0
A++
2.99
26
26
26
35
2.10
2.10
2.10
2.80
3.26
9.10
10.65
0.83
2.52
3.05
3.61
4.0
A++
2.99
73 73
RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS
COMBINED SYSTEMS KAM4-105 DN7
R-410A MULTISYSTEM
x1
x2
x3
x4
20
20 +20
20 +20 +20
20 +20 +20 +20
26
20 +26
20 +20 +26
20 +20 +20 +26
35
20 +35
20 +20 +35
20 +20 +20 +35
52
20 +52
20 +20 +52
20 +20 +20 +52
71
20 +71
20 +20 +71
20 +20 +20 +71
26+26
20 +26 +26
20 +20 +26 +26
26+35
20 +26 +35
20 +20 +26 +35
26+52
20 +26 +52
20 +20 +26 +52
26+71
20 +26 +71
20 +20 +26 +71
35+35
20 +35 +35
20 +20 +35 +35
35+52
20 +35 +52
20 +20 +35 +52
35+71
20 +35 +71
20 +20 +52 +52
52+52
20 +52 +52
20 +26+26+26
26+26+26
20 +26+26+35
26+26+35
20 +26+26+52
26+26+52
20 +26+26+71
26+35+35
20 +26+35+35
26+35+52
20 +26+35+52
26+35+71
20 +26+52+52
26+52+52
20 +35+35+35
35+35+35
20 +35+35+52
35+35+52
26+26+26+26
35+35+71
26+26+26+35
35+52+52
26+26+26+52 26+26+35+35 26+26+35+52 26+35+35+35 26+35+35+52 35+35+35+35
74 74
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
COMBINED SYSTEMS
1x4
UNIT A
UNIT B
UNIT C
UNIT D
UNIT A
UNIT B
UNIT C
UNIT D
MINIMUM
RATED
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35
20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 35 35 35
20 20 20 20 20 26 26 26 26 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 35 35 35 35 35
20 26 35 52 71 26 35 52 71 35 52 52 26 35 52 71 35 52 52 35 52 26 35 52 35 52 35 52 35
2.05 1.98 2.02 1.88 1.65 1.97 2.00 1.79 1.58 1.93 1.67 1.47 1.96 2.01 1.73 1.51 1.86 1.61 1.43 1.73 1.51 2.65 2.45 2.12 2.27 1.99 2.12 1.87 2.65
2.05 1.98 2.02 1.88 1.65 1.97 2.00 1.79 1.58 1.93 1.67 1.47 2.51 2.58 2.22 1.95 2.39 2.07 1.83 2.96 2.60 2.65 2.45 2.12 2.27 1.99 2.83 2.49 2.65
2.05 1.98 2.02 1.88 1.65 2.53 2.57 2.30 2.03 3.32 2.86 3.78 2.51 2.58 2.22 1.95 3.18 2.77 3.67 2.96 2.60 2.65 2.45 2.12 3.03 2.65 2.83 2.49 2.65
2.05 2.55 3.45 4.85 5.65 2.53 3.43 4.61 5.41 3.32 4.30 3.78 2.51 3.44 4.44 5.19 3.18 4.15 3.67 2.96 3.89 2.65 3.26 4.24 3.03 3.98 2.83 3.74 2.65
3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71 3.71
8.20 8.50 9.50 10.50 10.60 9.00 10.00 10.50 10.60 10.50 10.50 10.50 9.50 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60 10.60
COMBINATIONS UNIT A
1x4
HEATING CAPACITY (KW)
RATED CAPACITY (KW);
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35
UNIT B 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 35 35 35
RATED CAPACITY (KW)
MAXIMUM MINIMUM 10.60 11.66 12.72 13.78 13.78 12.72 13.25 13.78 13.78 13.78 13.78 13.78 13.25 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78 13.78
HEATING CAPACITY (KW)
UNIT C
UNIT D
UNIT A
UNIT B
UNIT C
UNIT D
MINIMUM
RATED
20 20 20 20 20 26 26 26 26 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 35 35 35 35 35
20 26 35 52 71 26 35 52 71 35 52 52 26 35 52 71 35 52 52 35 52 26 35 52 35 52 35 52 35
2.50 2.36 2.31 1.99 1.73 2.38 2.22 1.90 1.65 2.04 1.77 1.55 2.29 2.10 1.81 1.59 1.94 1.69 1.49 1.81 1.59 2.78 2.56 2.22 2.38 2.08 2.22 1.96 2.78
2.50 2.36 2.31 1.99 1.73 2.38 2.22 1.90 1.65 2.04 1.77 1.55 2.94 2.70 2.32 2.04 2.50 2.17 1.92 3.10 2.72 2.78 2.56 2.22 2.38 2.08 2.96 2.61 2.78
2.50 2.36 2.31 1.99 1.73 3.07 2.85 2.44 2.13 3.51 3.03 4.00 2.94 2.70 2.32 2.04 3.33 2.90 3.84 3.10 2.72 2.78 2.56 2.22 3.17 2.78 2.96 2.61 2.78
2.50 3.03 3.96 5.12 5.92 3.07 3.81 4.87 5.67 3.51 4.54 4.00 2.94 3.60 4.65 5.44 3.33 4.34 3.84 3.10 4.08 2.78 3.42 4.44 3.17 4.16 2.96 3.92 2.78
3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89 3.89
10.00 10.10 10.90 11.10 11.10 10.90 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10 11.10
EER SEER (W/W)
POWER POWER (KW)
0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89 0.89
MAXIMUM
2.30 2.50 2.88 3.27 3.30 2.73 3.12 3.27 3.30 3.27 3.27 3.27 2.94 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30
3.30 3.47 3.63 4.29 4.29 3.63 3.96 4.29 4.29 4.29 4.29 4.29 3.80 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29 4.29
POWER INPUT (KW)
MAXIMUM MINIMUM 11.10 11.66 12.21 13.32 13.32 12.21 12.77 13.32 13.32 13.32 13.32 13.32 12.77 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32 13.32
RATED
0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83
RATED
MAXIMUM
2.59 2.69 2.95 3.04 3.04 2.95 3.00 3.06 3.06 3.04 3.06 3.06 3.00 3.05 3.06 3.06 3.05 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06 3.06
3.06 3.21 3.36 3.98 3.98 3.36 3.67 3.98 3.98 3.98 3.98 3.98 3.52 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98
ENERGY CLASS
RATED CAPACITY 3.56 3.40 3.30 3.21 3.21 3.30 3.21 3.21 3.21 3.21 3.21 3.21 3.23 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21
COP (W/W)
7.6 7.6 7.6 7.4 7.4 7.6 7.6 7.6 7.6 7.6 7.6 7.4 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.4 7.6 7.6 7.6 7.6 7.6 7.6 7.4 7.6
SCOP
A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
ENERGY CLASS
COP -7
A A A A A A A A A A A A A A A A A A A A A A A A A A A A A
3.20 3.11 3.07 3.02 3.02 3.07 3.07 3.01 3.01 3.02 3.01 3.01 3.07 3.02 3.01 3.01 3.02 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01 3.01
RATED CAPACITY 3.86 3.75 3.70 3.65 3.65 3.70 3.70 3.63 3.63 3.65 3.63 3.63 3.70 3.64 3.63 3.63 3.64 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63 3.63
3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8
75 75
RESIDENTIAL PRODUCT RANGE R-410A COMBINED UNITS
COMBINED SYSTEMS KAM5-120 DN7
R-410A MULTISYSTEM
x1
x2
x3
x4
20
20+20
20+20+20
20+20+20+20
20+20+20+20+20
26
20+26
20+20+26
20+20+20+26
20+20+20+20+26
35
20+35
20+20+35
20+20+20+35
20+20+20+20+35
52
20+52
20+20+52
20+20+20+52
20+20+20+20+52
71
20+71
20+20+71
20+20+20+71
20+20+20+20+71
26+26
20+26+26
20+20+26+26
20+20+20+26+26
26+35
20+26+35
20+20+26+35
20+20+20+26+35
26+52
20+26+52
20+20+26+52
20+20+20+26+52
26+71
20+26+71
20+20+26+71
20+20+20+26+71
35+35
20+35+35
20+20+35+35
20+20+20+35+35
35+52
20+35+52
20+20+35+52
20+20+20+35+52
35+71
20+35+71
20+20+35+71
20+20+20+35+71
52+52
20+52+52
20+20+52+52
20+20+20+52+52
52+71
26+26+26
20+20+52+71
20+20+26+26+26
71+71
26+26+35
20+26+26+26
20+20+26+26+35
26+26+52
20+26+26+35
20+20+26+26+52
26+26+71
20+26+26+52
20+20+26+26+71
26+35+35
20+26+26+71
20+20+26+35+35
26+35+52
20+26+35+35
20+20+26+35+52
26+35+71
20+26+35+52
20+20+26+52+52
26+52+52
20+26+35+71
20+20+35+35+35
35+35+35
20+26+52+52
20+20+35+35+52
35+35+52
20+26+52+71
20+26+26+26+26
35+35+71
20+35+35+35
20+26+26+26+35
35+52+52
20+35+35+52
20+26+26+26+52
35+52+71
20+35+52+52
20+26+26+26+71
52+52+52
20+35+52+71
20+26+26+35+35
26+26+26+26
20+26+26+35+52
26+26+26+35
20+26+35+35+35
26+26+26+52
20+26+35+35+52
26+26+26+71
20+35+35+35+35
26+26+35+35
26+26+26+26+26
26+26+35+52
26+26+26+26+35
26+26+35+71
26+26+26+26+52
26+26+52+52
26+26+26+35+35
26+35+35+35
26+26+26+35+52
26+35+35+52
26+26+35+35+35
26+35+35+71
26+35+35+35+35
26+35+52+52 35+35+35+35 35+35+35+52
76 76
x5
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution RATED CAPACITY (kW)
COMBINED SYSTEMS
1x5
HEATING CAPACITY (kW)
UNIT A
UNIT B
UNIT C
UNIT D
UNIT E
UNIT A
UNIT B
UNIT C
UNIT D
UNIT E
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 26 35 26 26 26 26 26 26 35
20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 26 35 35 35 26 26 26 26 26 35 35
20 20 20 20 20 26 26 26 26 35 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 26 35 35 35 35 35 26 26 26 35 35 35 35
20 26 35 52 71 26 35 52 71 35 52 71 52 26 35 52 71 35 52 52 35 52 26 35 52 71 35 52 35 52 35 26 35 52 35 52 35 35
2.10 2.08 2.01 1.87 1.66 2.06 2.00 1.79 1.59 1.91 1.69 1.51 1.51 2.05 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.00 1.87 1.66 1.48 1.76 1.57 1.66 1.48 1.57 2.46 2.31 2.05 2.17 1.94 2.05 1.94
2.10 2.08 2.01 1.87 1.66 2.06 2.00 1.79 1.59 1.91 1.69 1.51 1.51 2.05 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.57 2.41 2.13 1.91 2.26 2.01 2.13 1.91 2.68 2.46 2.31 2.05 2.17 1.94 2.05 2.59
2.10 2.08 2.01 1.87 1.66 2.06 2.00 1.79 1.59 1.91 1.69 1.51 1.51 2.63 2.52 2.21 1.98 2.36 2.09 1.88 2.95 2.64 2.57 2.41 2.13 1.91 2.26 2.01 2.84 2.54 2.68 2.46 2.31 2.05 2.17 1.94 2.73 2.59
2.10 2.08 2.01 1.87 1.66 2.65 2.57 2.31 2.05 3.28 2.89 2.59 3.88 2.63 2.52 2.21 1.98 3.14 2.78 3.75 2.95 2.64 2.57 2.41 2.13 1.91 3.01 2.68 2.84 2.54 2.68 2.46 2.31 2.05 2.89 2.59 2.73 2.59
2.10 2.68 3.45 4.81 5.68 2.65 3.43 4.61 5.47 3.28 4.34 5.18 3.88 2.63 3.35 4.43 5.27 3.14 4.18 3.75 2.95 3.95 2.57 3.21 4.26 5.09 3.01 4.03 2.84 3.82 2.68 2.46 3.08 4.10 2.89 3.88 2.73 2.59
4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18
10.50 11.00 11.50 12.30 12.30 11.50 12.00 12.30 12.30 12.30 12.30 12.30 12.30 12.00 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30
14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00 14.00
1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01 1.01
3.09 3.24 3.42 3.73 3.76 3.42 3.57 3.73 3.76 3.69 3.75 3.80 3.80 3.57 3.69 3.75 3.80 3.73 3.76 3.84 3.73 3.76 3.69 3.73 3.76 3.80 3.73 3.76 3.75 3.80 3.75 3.73 3.73 3.76 3.75 3.80 3.75 3.76
4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55 4.55
RATED CAPACITY (kW)
COMBINED SYSTEMS
HEATING CAPACITY (kW)
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E
1x5
POWER INPUT (kW)
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 26 35 26 26 26 26 26 26 35
20 20 20 20 20 20 20 20 20 20 20 20 20 26 26 26 26 26 26 26 35 35 26 26 26 26 26 26 35 35 35 26 26 26 26 26 35 35
20 20 20 20 20 26 26 26 26 35 35 35 52 26 26 26 26 35 35 52 35 35 26 26 26 26 35 35 35 35 35 26 26 26 35 35 35 35
20 26 35 52 71 26 35 52 71 35 52 71 52 26 35 52 71 35 52 52 35 52 26 35 52 71 35 52 35 52 35 26 35 52 35 52 35 35
2.46 2.33 2.15 1.87 1.66 2.21 2.05 1.79 1.59 1.91 1.69 1.51 1.51 2.10 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.00 1.87 1.66 1.48 1.76 1.57 1.66 1.48 1.57 2.46 2.31 2.05 2.17 1.94 2.05 1.94
2.46 2.33 2.15 1.87 1.66 2.21 2.05 1.79 1.59 1.91 1.69 1.51 1.51 2.10 1.96 1.72 1.54 1.83 1.62 1.46 1.72 1.54 2.57 2.41 2.13 1.91 2.26 2.01 2.13 1.91 2.68 2.46 2.31 2.05 2.17 1.94 2.05 2.59
2.46 2.33 2.15 1.87 1.66 2.21 2.05 1.79 1.59 1.91 1.69 1.51 1.51 2.70 2.52 2.21 1.98 2.36 2.09 1.88 2.95 2.64 2.57 2.41 2.13 1.91 2.26 2.01 2.84 2.54 2.68 2.46 2.31 2.05 2.17 1.94 2.73 2.59
2.46 2.33 2.15 1.87 1.66 2.84 2.64 2.31 2.05 3.28 2.89 2.59 3.88 2.70 2.52 2.21 1.98 3.14 2.78 3.75 2.95 2.64 2.57 2.41 2.13 1.91 3.01 2.68 2.84 2.54 2.68 2.46 2.31 2.05 2.89 2.59 2.73 2.59
2.46 2.99 3.69 4.81 5.68 2.84 3.51 4.61 5.47 3.28 4.34 5.18 3.88 2.70 3.35 4.43 5.27 3.14 4.18 3.75 2.95 3.95 2.57 3.21 4.26 5.09 3.01 4.03 2.84 3.82 2.68 2.46 3.08 4.10 2.89 3.88 2.73 2.59
POWER INPUT (kW)
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18 4.18
12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30 12.30
14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94 14.94
0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91
3.40 3.40 3.40 3.37 3.28 3.40 3.40 3.32 3.28 3.40 3.32 3.28 3.28 3.40 3.40 3.32 3.28 3.37 3.37 3.28 3.37 3.28 3.40 3.37 3.28 3.28 3.37 3.28 3.32 3.28 3.32 3.37 3.37 3.28 3.32 3.28 3.32 3.28
4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21 4.21
EER SEER (W/W) (W/W)
ENERGY CLASS
RATED CAPACITY 3.40 7.7 3.40 7.7 3.37 7.7 3.30 7.7 3.27 7.7 3.37 7.7 3.37 7.7 3.30 7.7 3.27 7.7 3.33 7.7 3.28 7.7 3.23 7.7 3.23 7.7 3.37 7.7 3.33 7.7 3.28 7.7 3.23 7.7 3.30 7.7 3.27 7.7 3.20 7.7 3.30 7.7 3.27 7.7 3.33 7.7 3.30 7.7 3.27 7.7 3.23 7.7 3.30 7.7 3.27 7.7 3.28 7.7 3.23 7.7 3.28 7.7 3.30 7.7 3.30 7.7 3.27 7.7 3.28 7.7 3.23 7.7 3.28 7.7 3.27 7.7
A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
COP SCOP (W/W)
ENERGY CLASS
COP -7
RATED CAPACITY 3.62 3.7 3.62 3.8 3.62 3.8 3.65 3.8 3.75 3.6 3.62 3.8 3.62 3.8 3.71 3.8 3.75 3.8 3.62 3.8 3.71 3.6 3.75 3.5 3.75 3.5 3.62 3.8 3.62 3.8 3.71 3.8 3.75 3.5 3.65 3.6 3.65 3.6 3.75 3.4 3.65 3.6 3.75 3.6 3.62 3.8 3.65 3.8 3.75 3.8 3.75 3.5 3.65 3.8 3.75 3.6 3.71 3.6 3.75 3.4 3.71 3.6 3.65 3.8 3.65 3.8 3.75 3.5 3.71 3.6 3.75 3.5 3.71 3.6 3.75 3.5
A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A
2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94 2.94
77 77
RESIDENTIAL PRODUCT RANGE R-32 COMBINED UNITS
COMBINED SYSTEMS KAM2-52 DR7
R-32 MULTISYSTEM
x1
x2
26
26+26
35
26+35
52
26+52 35+35
KAM3-78 DR7
78 78
x1
x2
x3
26
26+26
26+26+26
35
26+35
26+26+35
52
26+52
26+26+52
35+35
26+35+35
35+52
26+35+52
52+52
35+35+35
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
RATED CAPACITY (kW)
COMBINED SYSTEMS
1x2
UNIT A
UNIT B
UNIT A
26
26
2.64
26
35
2.27
UNIT B
MINIMUM
RATED
ENERGY CLASS
SEER
MINIMUM
RATED
MAXIMUM RATED CAPACITY
2.64
2.11
5.28
6.44
0.54
1.63
2.04
3.23
6.6
A++
3.03
2.11
5.3
6.44
0.54
1.64
2.04
3.23
6.6
A++
52
1.8
3.6
2.11
5.4
6.49
0.54
1.65
2.04
3.27
6.6
A++
35
2.65
2.65
2.11
5.3
6.44
0.54
1.64
2.04
3.23
6.6
A++
RATED CAPACITY (kW)
UNIT A
UNIT B
UNIT A
UNIT B
26
26
2.79
26
35
2.4
26
52
1.93
35
35
2.8
HEATING POWER (kW)
POWER INPUT (kW) MAXIMUM MINIMUM
RATED CAPACITY
2.23
5.57
6.8
0.47
1.39
1.88
4.0
4.0
A+
3.2
2.23
5.6
6.8
0.47
1.4
1.88
4.0
4.0
A+
3.2
3.87
2.23
5.8
6.85
0.47
1.46
1.88
3.97
4.0
A+
3.17
2.8
2.23
5.6
6.8
0.47
1.4
1.88
4.0
4.0
A+
3.2
HEATING CAPACITY (kW)
UNIT B
UNIT C
MINIMUM
RATED
26
26
26
2.63
2.63
2.63
2.77
7.9
8.69
26
26
35
2.37
2.37
3.16
2.77
7.9
8.69
26
26
52
1.98
1.98
3.95
2.77
7.9
26
35
35
2.15
2.87
2.87
2.77
26
35
52
1.82
2.43
3.65
35
35
35
2.63
2.63
2.63
RATED CAPACITY (kW) UNIT B
UNIT C
MINIMUM
MAXIMUM
POWER INPUT (kW)
UNIT A
UNIT A
COP -7
3.2
UNIT C
UNIT C
ENERGY CLASS
2.79
UNIT B
UNIT B
RATED
SCOP
RATED
UNIT A
UNIT A
COP (W/W)
MINIMUM
RATED CAPACITY (kW)
COMBINED SYSTEMS
1x3
MAXIMUM
EER (W/W)
35
COMBINED SYSTEMS
1x3
POWER INPUT (kW)
26
COMBINED SYSTEMS
1x2
HEATING CAPACITY (kW)
MAXIMUM MINIMUM
EER (W/W)
SEER
ENERGY CLASS
RATED
MAXIMUM
0.74
2.39
2.9
3.3
6.7
A++
0.74
2.39
2.9
3.31
6.7
A++
8.69
0.74
2.39
2.9
3.31
6.7
A++
7.9
8.69
0.74
2.38
2.9
3.32
6.7
A++
2.77
7.9
8.69
0.74
2.38
2.9
3.32
6.7
A++
2.77
7.9
8.69
0.74
2.38
2.9
3.32
6.7
A++
SCOP
ENERGY CLASS
HEATING POWER (kW)
POWER INPUT (kW)
RATED
RATED
MAXIMUM MINIMUM
COP (W/W) MAXIMUM
RATED CAPACITY
COP -7
RATED CAPACITY
26
26
26
2.73
2.73
2.73
2.87
8.2
9.02
0.68
2.20
2.62
3.73
4.0
A+
3.13
26
26
35
2.49
2.49
3.32
2.87
8.3
9.02
0.68
2.22
2.62
3.74
4.0
A+
3.14
26
26
52
2.08
2.08
4.15
2.87
8.3
9.02
0.68
2.22
2.62
3.74
4.0
A+
3.14
26
35
35
2.26
3.02
3.02
2.87
8.3
9.02
0.68
2.21
2.62
3.76
4.0
A+
3.16
26
35
52
1.92
2.56
3.83
2.87
8.3
9.02
0.68
2.22
2.62
3.74
4.0
A+
3.14
35
35
35
2.77
2.77
2.77
2.87
8.3
9.02
0.68
2.21
2.62
3.76
4.0
A+
3.16
79 79
RESIDENTIAL PRODUCT RANGE R-32 COMBINED UNITS
COMBINED SYSTEMS KAM4-105 DR7
R-32 MULTISYSTEM
x1
x2
x3
x4
26
26+26
26+26+26
26+26+26+26
35
26+35
26+26+35
26+26+26+35
52
26+52
26+26+52
26+26+26+52
70
26+70
26+26+70
26+26+35+35
35+35
26+35+35
26+26+35+52
35+52
26+35+52
26+35+35+35
35+70
26+35+70
26+35+35+52
52+52
26+52+52
35+35+35+35
35+35+35
35+35+35+52
35+35+52 35+35+70 35+52+52
KAM5-120 DR7
x1
x2
x3
x4
x5
26
26+26
26+26+26
26+26+26+26
26+26+26+26+26
35
26+35
26+26+35
26+26+26+35
26+26+26+26+35
52
26+52
26+26+52
26+26+26+52
26+26+26+26+52
71
26+71
26+26+71
26+26+26+71
26+26+26+35+35
35+35
26+35+35
26+26+35+35
26+26+26+35+52
35+52
26+35+52
26+26+35+52
26+26+35+35+35
35+71
26+35+71
26+26+35+71
26+35+35+35+35
52+52
26+52+52
26+35+35+35
26+35+35+35+52
35+35+35
26+35+35+52
35+35+35+35+35
35+35+52
35+35+35+35
35+35+71
35+35+35+52
35+52+52
80 80
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
RATED CAPACITY (KW)
COMBINED SYSTEMS
1x4
UNIT A
UNIT B
UNIT C
UNIT
UNIT A
26
26
26
26
2.63
26
26
26
35
2.42
26
26
26
52
2.1
26
26
35
35
26
26
35
26
35
35
26
35
35
35
35
35
35
UNIT D
MIN.
RATED
MAX.
MIN.
RATED
MAX.
2.63
2.63
2.63
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
2.42
2.42
3.23
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
2.1
2.1
4.2
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
2.25
2.25
3
3
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
52
1.97
1.97
2.63
3.94
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
35
2.1
2.8
2.8
2.8
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
52
1.85
2.47
2.47
3.71
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
35
35
2.63
2.63
2.63
2.63
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
35
52
2.33
2.33
2.33
3.5
3.68
10.5
13.65
0.95
3.5
4.27
3.0
6.5
A++
ENERGY CLASS
COP -7
RATED CAPACITY (KW)
UNIT A
UNIT B
UNIT C
UNIT
UNIT A
UNIT B
UNIT C
26
26
26
26
2.78
2.78
26
26
26
35
2.56
2.56
26
26
26
52
2.22
2.22
2.22
26
26
35
35
2.38
2.38
26
26
35
52
2.08
2.08
26
35
35
35
2.22
2.96
26
35
35
52
1.96
35
35
35
35
35
35
35
52
MIN.
RATED
MAX.
MIN.
RATED
MAX.
2.78
2.78
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
2.56
3.42
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
4.44
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
3.17
3.17
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
2.78
4.16
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
2.96
2.96
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
2.61
2.61
3.92
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
2.78
2.78
2.78
2.78
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
2.47
2.47
2.47
3.70
3.89
11.1
13.32
0.79
2.91
3.79
3.81
4.0
A
3.11
RATED CAPACITY (kW)
HEATING CAPACITY (kW)
RATED CAPACITY
EER SEER (W/W) (W/W)
POWER INPUT (kW)
ENERGY CLASS
UNIT E
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
RATED CAPACITY
2.46
2.46
4.18
12.3
14
1.11
4.1
4.55
3.0
6.8
A++
2.31
3.08
4.18
12.3
14
1.11
4.1
4.55
3.0
6.8
A++
2.05
2.05
4.1
4.18
12.3
14
1.11
4.09
4.55
3.01
6.8
A++
2.17
2.17
2.89
2.89
4.18
12.3
14
1.11
4.07
4.55
3.02
6.8
A++
1.94
1.94
1.94
2.59
3.88
4.18
12.3
14
1.11
4.09
4.55
3.01
6.8
A++
35
2.05
2.05
2.73
2.73
2.73
4.18
12.3
14
1.11
4.07
4.55
3.02
6.8
A++
35
35
1.94
2.59
2.59
2.59
2.59
4.18
12.3
14
1.11
4.09
4.55
3.01
6.8
A++
35
35
52
1.76
2.34
2.34
2.34
3.51
4.182
12.3
14
1.11
4.09
4.55
3.00
6.8
A++
35
35
35
2.46
2.46
2.46
2.46
2.46
4.182
12.3
14
1.11
4.09
4.55
3.00
6.8
A++
UNIT A
UNIT B
UNIT C
UNIT D
UNIT E
UNIT A
UNIT B
UNIT C
UNIT D
26
26
26
26
26
2.46
2.46
2.46
26
26
26
26
35
2.31
2.31
2.31
26
26
26
26
52
2.05
2.05
26
26
26
35
35
2.17
26
26
26
35
52
26
26
35
35
26
35
35
26
35
35
35
RATED CAPACITY (kW)
COMBINED SYSTEMS
HEATING CAPACITY (kW)
UNIT A UNIT B UNIT C UNIT D UNIT E UNIT A UNIT B UNIT C UNIT D UNIT E
1x5
COP W/W SCOP
POWER INPUT (kW)
HEATING CAPACITY (KW)
RATED CAPACITY
UNIT D
COMBINED SYSTEMS
1x5
ENERGY CLASS
SEER
UNIT C
COMBINED SYSTEMS
1x4
UNIT B
EER W/W
POWER INPUT (kW)
COOLING CAPACITY (KW)
COP SCOP (W/W)
POWER INPUT (kW)
MIN.
RAT.
MAX.
MIN.
RAT.
MAX.
ENERGY CLASS
COP -7
RATED CAPACITY
26
26
26
26
26
2.46
2.46
2.46
2.46
2.46
4.18
12.3
14.94
0.9
3.32
4.14
3.71
4.0
A
3.01
26
26
26
26
35
2.31
2.31
2.31
2.31
3.08
4.18
12.3
14.94
0.9
3.32
4.14
3.71
4.0
A
3.01
26
26
26
26
52
2.05
2.05
2.05
2.05
4.1
4.18
12.3
14.94
0.9
3.23
4.14
3.81
3.5
A
3.11
26
26
26
35
35
2.17
2.17
2.17
2.89
2.89
4.18
12.3
14.94
0.9
3.26
4.14
3.77
3.8
A
3.07
26
26
26
35
52
1.94
1.94
1.94
2.59
3.88
4.18
12.3
14.94
0.9
3.23
4.14
3.81
3.5
A
3.11
26
26
35
35
35
2.05
2.05
2.73
2.73
2.73
4.18
12.3
14.94
0.9
3.3
4.14
3.77
3.8
A
3.07
26
35
35
35
35
1.94
2.59
2.59
2.59
2.59
4.18
12.3
14.94
0.9
3.2
4.14
3.81
3.5
A
3.11
26
35
35
35
52
1.84
1.84
2.46
2.46
3.69
4.182
12.3
14.94
0.9
3.2
4.14
3.81
3.8
A
3.11
35
35
35
35
35
2.46
2.46
2.46
2.46
2.46
4.182
12.3
14.94
0.9
3.2
4.14
3.81
3.5
A
3.11
81 81
RESIDENTIAL PRODUCT RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
VILLA BAHIA PRINCIPE RESIDENTIAL Location: Dominican Republic Units installed: Multisystem Suite Capacity: 34 kW
THE SUITE RESIDENTIAL RANGE IS PRESENT IN THE MOST COMMON PLACES. FROM APARTMENTS TO HOSPITALS, SCHOOLS AND UNIVERSITIES, THE COMFORT AND TECHNOLOGY OF THIS RANGE PROVIDES THE WELL-BEING THAT ALL HOMES NEED.
OTHER CUSTOMERS THAT TRUSTED KAYSUN SUITE HOTELS Vera Apart-Hotel (Almeria) Sangulí Resort Salou (Tarragona)
SCHOOLS AND UNIVERSITIES University of Salamanca (Salamanca), The Capuchins School (Murcia), María Maroto School (Murcia), Autism Association of Jerez (Cádiz)
LEISURE CENTRES Vals Sport - Sports Centre (Malaga) HOSPITAL, CLINICS AND HEALTH CENTRES Jesus Nazareno Hospital (Córdoba), Santomera Health Centre (Murcia) BUSINESS CENTRES AND OFFICES ISOLAIS Office (Seville)
82 82
RESIDENCES 51 residences in Carrión (Seville), 52 residences in Torreblanca (Seville), La Pineda Apartments (Tarragona), Puerto Mahón Apartments (Majorca), Jardines de Santa Ana Residence (Seville)
SUITE RESIDENTIAL
Inspiration, Innovation, Evolution
SANGULĂ? SALOU CAMPING RESORT
Location: Cambrils (Tarragona) Units installed: Suite 1X1
ESCUELA MARIA MAROTO SCHOOLS
Location: Murcia Units installed: Multisystem Suite
83 83
AQUATIX DOMESTIC HOT WATER RANGE
INTRODUCTION TO THE PRODUCT RANGE.......................................86
UNITS Aquantia.................................................Monobloc...........................94 Aquantia.................................................Bibloc.................................98 Domestic hot water tanks.....................BS, G..................................102 Compak..................................................KHP ACS...........................106 KEY INSTALLATIONS..........................................................................108
AQUATIX DOMESTIC HOT WATER
AQUATIX
DOMESTIC HOT WATER RANGE
DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
AQUATIX
DOMESTIC HOT WATER RANGE
The Aquatix range reveals the vital energy of water and how to make the most of the resources in a single space. Using a heat pump system, hot water with temperatures of up to 70ºCcan be produced, putting the best qualities of this natural resource to work to heat the home with domestic hot water and underfloor heating. The Aquatix heat pump is an alternative to the traditional hot water boiler, and saves a significant amount of energy, offering a broad variety of advantages for the home with with maximum energy efficiency.
“THE MOST ECOLOGICAL INNOVATION FOR YOUR HOME”
Aquatix equipment is designed for spaces located in the home, allowing for fast and simple installation. We often seek an alternative system to provide comfort, and the search needs not go further than the Aquatix range, with the most advanced technology and maximum savings.
AQUANTIA Discover Aquantia, the integrated system that provides heating, climate control and domestic hot water to your home. Enjoy maximum comfort all year round, with the great energy efficiency that characterises this system based on heat pumps. The reversible heat pump is a system that obtains renewable energy from outside to heat or cool your home. It is the most efficient technology, absorbing more energy from the exterior than what Aquantia consumes. As well as being more environmentally-friendly and energy efficient than other systems such as boilers, Aquantia can replace all of these systems and work together with them.
+ + + +
86
IT OFFERS HEATING, CLIMATE CONTROL AND DOMESTIC HOT WATER: A YEAR-ROUND SOLUTION
ENERGY EFFICIENT (ENVIRONMENT, ECONOMIC)
WIDE RANGE OF OPERATING TEMPERATURES
CAN FUNCTION WITH OTHER SOURCES OF ENERGY, SUCH AS SOLAR ENERGY AND BOILERS
Radiators
Heating: • • • •
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
Underfloor heating Radiators Fan Coils Combination of the above
Climate control: • • •
Fan Coils Underfloor cooling Combination of the above
DOMESTIC HOT WATER: •
Accumulation tanks
Water tank Heating water Hot Water
Underfloor heating Aquantia
Aquantia supplies hot and cold water to its underfloor heating, radiators, fan coils and water tanks. In addition to being a totally independent source of energy, it can also work with external sources (solar energy, boilers, etc.).
THERE ARE TWO INSTALLATION OPTIONS, DEPENDING ON YOUR REQUIREMENTS:
MONOBLOC
BIBLOC POMPE À CHALEUR
All components in the compact outdoor unit.
A hydraulic system in an indoor unit and a heat pump in an outdoor unit.
87
DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
AQUANTIA CONTROL •
Touch control
•
A choice of operating modes
•
Priority manager
•
Temperature setpoints
•
Daily and weekly scheduling
•
Option to enquire about working parameters, error codes, service calls
•
Different levels of user
•
Test Run
•
Follow Me function (temperature sensor built into the control)
•
Modbus communication
KCTAQ-01 SOME FUNCTIONS •
Silence mode: Minimum noise levels guaranteed
•
Forced domestic hot water mode
•
Disinfection mode: Raises temperature to 70ºC
•
Air purging
•
Pre-heating of the environment
•
Dehumidify the ground
•
Choose from various operating modes (eco mode, holiday mode) and priorities
Domestic hot water tank
Thermostat 2
Touch control
T Indoor unit
Radiator Zone 2
Zone 2 controlled by thermostat 2
Zone 1
Zone 1 controlled by thermostat 1
M
Outdoor unit
M
3-way valve
2-way valve
T Thermostat 1
88
Underfloor heating
Inspiration, Innovation, Evolution
AQUATIX DOMESTIC HOT WATER
Heat capacity of up to 80% at -7ºC, thanks to the size of the exchanger and compressor
Heat exchanger 9.5 pipe with internal groove optimises the efficiency of the heat exchange. The flaps increase the heat exchange area and reduce air resistance. The blue coat increases resistance against corrosive agents and increases durability.
Hydronic module Hydronic module with integrated DC water pump (monobloc) or separate DC water pump (bibloc)
Ventilator with brushless DC motor DC motors with stage-free controls reduce noise and consumption of the system
Compressor with DC inverter Support resistance
The novel double rotary compressor with DC inverter produces less noise, greater operating frequency and more accurate control. The feeder system and this greater frequency reduce consumption by more than 30%.
It has support electric resistance for extreme outdoor temperatures
Highly efficient DC motor Simple rotary
- Redesigned core motor
Double rotary
- High-density neodymium magnet - Concentrated stator - Wide range of operating temperatures Minimal vibration - Twin eccentric cams - 2 balance weights Highly stable moving parts - Perfect fit of motor components - Optimised compressor action - Very robust ball bearings
Double rotary compressor
- Compact structure
EASY INSTALLATION, MINIMAL MAINTENANCE •
Compact structure. The hydronic part can be installed indoors or outdoors.
•
Easily connected to the pipe system of the house.
•
Rapid access to the components of the system for inspection and maintenance
SMART, ADAPTABLE SYSTEM •
Select a work curve. Depending on the desired temperature, the system will automatically adapt when the temperature outside changes.
WIDE RANGE OF OPERATING TEMPERATURES
60°C
DOMESTIC HOT WATER
50°C 40°C
Heating
43°C
70°C Cold
46°C
60°C
Heating 60°C
60°C
50°C
35°C
30°C
40°C
20°C
40°C
30°C
10°C 20°C
0°C -5°C
-10°C -20°C
DOMESTIC HOT WATER
-20°C
-20°C
Outdoor ambient temperature
Cold 25°C
25°C
10°C 5°C
5°C
Output water temperature
89
DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
ENVIRONMENTALLY DC INVERTER The traditional motors used in heat pumping systems waste energy, as they always work at full load. The technology used in the KAYSUN DC Inverter reduces energy consumption by up to 30%, since it adapts energy consumption to the actual load of the system.
WATER AT CONSTANT TEMPERATURE The rotation speed of the compressor is controlled with great precision and according to demand using DC Inverter technology. The temperature setpoint for the water remains stable, providing the user with greater comfort.
FEWER STOPS AND STARTS The technology of the inverter reduces the frequency of stop-start cycles. This extends the life of components and minimises noise.
QUIET Most of the time it is in operation, the energy requirements of the home are less than full capacity. As well as a Silence mode, due to the adjustable frequency of the compressor the equipment for the most part operates at less than full capacity, reducing noise levels.
BOTH PIECES OF EQUIPMENT (MONOBLOC AND BIBLOC) HAVE AN ERP ENERGY EFFICIENCY RATING OF A++
90
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
POWER RANGE
AQUANTIA MONOBLOC Heating capacity (kW)
4
(Page 94)
5
6
7
8
12
14
16
SINGLE-PHASE KHP-MO 5 DVN
KHP-MO 7 DVN
KHP-MO 12 DVN KHP-MO 14 DVN KHP-MO 16 DVN
TRI-PHASE KHP-MO 12 DTN KHP-MO 14 DTN KHP-MO 16 DTN
AQUANTIA BIBLOC Heating capacity (kW)
(Page 98) POMPE Ã&#x20AC; CHALEUR
4
5
6
7
8
12
14
16
KHP-BI 8 DVN
KHP-BI 12 DVN
KHP-BI 14 DVN
KHP-BI 16 DVN
KHP-BI 12 DTN
KHP-BI 14 DTN
KHP-BI 16 DTN
SINGLE-PHASE KHP-BI 4 DVN
KHP-BI 6 DVN
TRI-PHASE
91
DOMESTIC HOT WATER RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
COMPAK
POMPE ร CHALEUR
COMPAK KHP This compact unit, fitted with evaporator, condenser and built-in tank, is an optional solution to be considered for producing domestic hot water or underfloor heating. This option is easy to integrate into many spaces because it eliminates the need for many units, as everything is built into the same unit. These unit's condenser is built around the water tank, keeping the refrigerant and domestic hot water from coming into direct contact.
LITRES
150
200
250
300
COMPAK KHP 15 190 ACS1
350
COMPAK KHP 35 300 ACS1
Liquid deposit Ventilator/evaporator
Compressor
Thermostatic Expansion Valve AIR INLET
AIR INLET
Water tank
COMPAK KHP 15 190 ACS1
(Page 106)
The KAYSUN COMPAK KHP 15 190 ACS1 is an ideal option for domestic use. With a storage capacity of 190 litres and a power input of 500W, it is an interesting option for producing domestic hot water.
Water Magnesium anode
Condenser Resistances
COMPAK KHP 35 300 ACS1
(Page 106)
The new 3 kW COMPAK KHP unit with vitrified enamel, which allows water to be discharged at temperatures close to 70ยบC. This compact unit, equipped with a centrifugal fan and a static pressure of 25 Pa,allows to direct the air through a duct of up to 10 metres in length.
COMPAK KHP 35 300 ACS1
92
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
UNITS TECHNICAL SPECIFICATIONS
93
DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM
AQUANTIA MONOBLOC TECHNICAL SPECIFICATIONS MODEL
KHP-MO 5 DVN
Power Supply
V/ph/Hz kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W
Heating capacity1 Heating input power1 COP1 Heating capacity2 Heating input power2 COP2 Cooling capacity3 Cooling input power3 EER3 Cooling capacity4 Cooling input power4 EER4 SCOP (Average Zone) SCOP (Warm Zone)
Water 35ºC - Clas. Power Water 55ºC - Clas. Power Water 35ºC Water 55ºC
Compressor type Number of outdoor ventilators Outdoor airflow Exchanger type (water)
1 m3/h
Refrigerant oil type Refrigerant volume Volume of expansion tank Regulation Standard support heater Optional support heater
Output water temperature
mca kPa
6 58.4
Kg L
2.4 2
kW kW dB (A) dB (A) mm Kg mm (inch) Mpa L ºC ºC ºC ºC ºC ºC
3 45.4 46.8 945/1210/402 99 Ø25(1") 0.3 2
3100 6 58.4 2.4 2 Electric expansion valve
Heating7 Cooling8
Heat Cold DOMESTIC HOT WATER Heat Cold DOMESTIC HOT WATER
Rated capacities based on the following conditions: 1. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC. 2. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC. 3. Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC. 4. Air in condenser at 35ºC, water in input/output evaporator 12/7ºC. 5. Seasonal efficiency in Average Climate Zone. 6. Seasonal efficiency in Warm Climate Zone. 7. At 1 m distance, the compressor works with fixed frequency in nominal working condition 1. 8. At 1 m distance, the compressor works with fixed frequency in nominal working condition 3.
94
3100
R-410A
Height / Width / Depth Weight Water pipe connections Safety valve Total water volume Outdoor ambient temperature
1 Plates
Water pump pressure
Sound pressure
KHP-MO 7 DVN
220-240/1/50 220-240/1/50 4.58 6.55 3940 5630 0.97 1.45 4.72 4.52 4.67 6.69 4020 5750 1.43 2.05 3.27 3.26 4.55 6.45 3910 5550 1 1.47 4.55 4.4 4.55 6.71 3910 5770 1.55 2.57 2.94 2.61 4.47-A++ 4.53-A++ 3.29-A++ 3.29-A++ 5.8 6.28 3.71 4.27 Double Rotary DC Inverter
3 50.5 48.5 945/1210/402 99 Ø25(1") 0.3 2 -20~35 -5~46 -20~43 25~60 5~25 40~60
R-410A
KHP-MO 12 DVN 220-240/1/50 12.17 10460 2.73 4.46 12.58 10820 3.86 3.26 12.19 10480 2.65 4.60 12.21 10500 4.17 2.93 4.21-A++ 3.25-A++ 6.36 4.05
KHP-MO 12 TVN
KHP-MO 14 DVN
380-415/3/50 220-240/1/50 12.37 14.76 10640 12690 2.76 3.4 4.48 4.34 12.02 14.08 10340 12110 3.72 4.47 3.23 3.15 12.64 14.61 10870 12560 2.75 3.32 4.6 4.4 12.58 12.95 10820 11130 4.32 4.53 2.91 2.86 4.45-A++ 4.39-A++ 3.25-A++ 3.25-A++ 6.32 6.01 3.8 4.09 Double Rotary DC Inverter
2
2
6250
6250
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
ACS
KHP-MO 14 DTN 380-415/3/50 14.1 12120 3.26 4.33 14.11 12130 4.46 3.16 14.03 12060 3.26 4.3 13.8 11870 5.14 2.68 4.27-A++ 3.27-A++ 4.77 3.75
2
2
6250
6250
7.5 73.55
7.5 73.55
3.6 5
3.6 5
Plates 7.5 73.55
7.5 73.55
3.6 5
3.6 5
R-410A
3 50.7 52.3 1414/1404/405 162 Ø32(1 1/4") 0.3 5.5
Electric expansion valve 4.5 3 55.1 57.1 55.4 57.9 1414/1404/405 1414/1404/405 177 162 Ø32(1 1/4") Ø32(1 1/4") 0.3 0.3 5.5 5.5 -20~35 -5~46 -20~43 25~60 5~25 40~60
4.5 58.7 57.9 1414/1404/405 177 Ø32(1 1/4") 0.3 5.5
95
DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM
AQUANTIA MONOBLOC TECHNICAL SPECIFICATIONS MODEL
KHP-MO 16 DVN
Power
V/ph/Hz kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W kW kCal/h kW W/W
Heating capacity1 Heating input power1 COP1 Heating capacity2 Heating input power2 COP2 Cooling capacity3 Cooling input power3 EER3 Cooling capacity4 Cooling input power4 EER4 SCOP (Average Zone) SCOP (Warm Zone)
Water 35ºC - Clas. Power Water 55ºC - Clas. Power Water 35ºC Water 55ºC
Compressor type Number of outdoor ventilators Outdoor airflow Exchanger type (water)
2 m3/h mca kPa
Refrigerant oil type Refrigerant volume Volume of expansion tank Regulation Standard support heater Optional support heater
Output water temperature
Heating7 Cooling8
Heat Cold DOMESTIC HOT WATER Heat Cold DOMESTIC HOT WATER
kW kW dB (A) dB (A) mm Kg mm (inch) Mpa L ºC ºC ºC ºC ºC ºC
Rated capacities based on the following conditions: 1. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC. 2. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC. 3. Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC. 4. Air in condenser at 35ºC, water in input/output evaporator 12/7ºC. 5. Seasonal efficiency in Average Climate Zone. 6. Seasonal efficiency in Warm Climate Zone. 7. At 1 m distance, the compressor works with fixed frequency in nominal working condition 1. 8. At 1 m distance, the compressor works with fixed frequency in nominal working condition 3.
96
6250
6250
7.5 73.55
7.5 73.55 R-410A
Kg L
Height / Width / Depth Weight Water pipe connections Safety valve Total water volume Outdoor ambient temperature
2 Plates
Water pump pressure
Sound pressure
KHP-MO 16 DTN
220-240/1/50 380-415/3/50 16.33 16.3 14040 14020 3.9 3.88 4.19 4.2 16.12 16.06 13860 13810 5.22 5.23 3.09 3.07 14.82 15.1 12740 12980 3.66 3.78 4.05 4 13.72 15.26 11800 13120 5.16 6.41 2.66 2.38 4.26-A++ 4.17-A++ 3.2-A++ 3.22-A++ 5.54 5.38 3.95 4.31 Double Rotary DC Inverter
3.6 5
3.6 5
Electric expansion valve 3 4.5 59.2 59.0 57.6 57.8 1414/1404/405 1414/1404/405 162 177 Ø32(1 1/4") Ø32(1 1/4") 0.3 0.3 5.5 5.5 -20~35 -5~46 -20~43 25~60 5~25 40~60
R-410A
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
ACS
GENERAL CHARACTERISTICS
An integrated system that provides heating, climate control and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed. • DC ventilator and compressor. • Climate control and domestic hot water from a single piece of equipment. • It can operate on its own or draw on other energy sources already installed. • All components in a compact outdoor unit.
HEATING
+ + + +
UNDERFLOOR HEATING
RADIATORS
FANCOILS
COMBINATION OF THE ABOVE
CLIMATE CONTROL AQUANTIA SINGLE BLOC
+ + +
FANCOILS
COLD FLOOR
COMBINATION OF THE ABOVE
DOMESTIC HOT WATER
+
ACCUMULATION DEPOSITS
TOUCH CONTROL SMART, ADAPTABLE SYSTEM EASY INSTALLATION, MINIMAL MAINTENANCE WIDE RANGE OF OPERATING TEMPERATURES
ACCESSORY* KIT R 8 VN optional support heater kit *For KHP-MO 5 DVN and KHP-MO 7 DVN
97
DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM
AQUANTIA BIBLOC OUTDOOR UNIT
POMPE À CHALEUR
TECHNICAL SPECIFICATIONS MODEL Power
Heating input power1 COP1
Heating input power2 COP2
Cooling input power3 EER3 Cooling capacity4 Cooling input power4 EER4
8
kCal/h
3530
5250
6880
kW
0.82
1.29
1.73 4.62
5
4.73
kW
4.01
5.96
7.34
kCal/h
3450
5130
6310
kW
1.13
1.68
2.13
W/W
3.55
3.55
3.45
4.1
6.2
8
kCal/h
3530
5330
6880
kW
0.84
1.43
1.93
W/W
4.88
4.34
4.15
kW
4.12
6.15
6.44
kCal/h
5540
3540
5290
kW
1.3
2.08
2.24
W/W
3.17
2.96
2.88
Water 35ºC - Clas. Power
4.62-A++
4.68-A++
4.33-A++
3.25-A+
3.3-A+
3.2-A++
Water 35ºC
5.4
5.6
5.76
Water 55ºC
3.74
3.48
3.84
Double Rotary DC Inverter m3/h
1
1
3180
5116
2.5
2.5
2.8
Electric expansion valve Heating7
dB (A)
45.4
50.5
48.4
Cooling8
dB (A)
46.8
48.5
49.2
H
mm
960
960
900
Width
mm
860
860
1327
Depth
mm
380
380
400
Kg
60
60
76
mm (inch)
Ø9.5 (3/8”)
mm (inch)
Ø15.9(5/8”)
m
2/20
2/20
2/30
m
10
20
30
m
8
15
25
Heat
ºC
Cold
ºC
-5~46
DOMESTIC HOT WATER
ºC
-20~43
Recommended indoor unit
Rated capacities based on the following conditions: 1. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 30/35ºC. 2. Air in evaporator at 7ºC and 85% R.H., water in input/output condenser 40/45ºC. 3. Air in evaporator at 35ºC, water in input/output evaporator 23/18ºC. 4. Air in condenser at 35ºC, water in input/output evaporator 12/7ºC. 5. Seasonal efficiency in Average Climate Zone. 6. Seasonal efficiency in Warm Climate Zone. 7. At 1 m distance, the compressor works with fixed frequency in nominal working condition 1. 8. At 1 m distance, the compressor works with fixed frequency in nominal working condition 3.
98
1 3180
R-410A Kg
Weight Liquid side connections Gas side connections Total length (min.(max.) Outdoor unit pipe height (at the top) Outdoor unit pipe height (at the bottom) Outdoor ambient temperature
6.1
Water 55ºC - Clas. Power
Compressor type Number of outdoor ventilators Outdoor airflow Refrigerant oil type Refrigerant volume Regulation
Dimension
220-240/1/50
4.1
kW
Cooling capacity3
Sound pressure
KHP-BI 8 DVN
220-240/1/50
W/W
Heating capacity2
SCOP6 (Warm Zone)
KHP-BI 6 DVN
220-240/1/50
kW
Heating capacity1
SCOP5 (Average Zone)
KHP-BI 4 DVN V/ph/Hz
-20~35
KIT KHP BI 8 VN
KIT KHP BI 8 VN
KIT KHP BI 8 VN
R-410A
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
ACS
KHP-BI 12 DVN
KHP-BI 12 DTN
KHP-BI 14 DVN
KHP-BI 14 DTN
KHP-BI 16 DVN
KHP-BI 16 DTN
220-240/1/50
380-415/3/50
220-240/1/50
380-415/3/50
220-240/1/50
380-415/3/50
12.1
12
14
14
15.5
15.5
10400
10320
12040
12040
13330
13330
2.74
2.66
3.39
3.26
3.82
3.79
4.42
4.51
4.13
4.29
4.06
4.09
11.85
11.97
14.05
13.93
16.05
15.48
10190
10290
12080
11980
13800
13310
3.48
3.5
4.41
4.21
5.03
4.87
3.41
3.42
3.19
3.31
3.19
3.18
11.7
12
13.1
13.5
13.8
14.5
10060
10320
11260
11610
11870
12470
2.79
2.8
3.48
3.45
3.77
3.94
4.19
4.29
3.76
3.91
3.66
3.68
11.02
11.7
12.49
12.53
12.85
12.91
9480
10060
10740
10770
11050
11100
4.17
4.65
5.07
5.21
5.39
5.52
2.64
2.52
2.46
2.4
2.38
2.34
4.46-A++
4.58-A++
4.28-A++
4.62-A++
4.01-A++
4.37-A++
3.24-A++
3.23-A++
3.24-A++
3.31-A++
3.2-A+
3.29-A++
6.1
6.74
5.25
6.42
5.23
5.9
4.26
4.08
4.13
4.13
4.44
4.11
2
2
2
2
2
2
6250
6250
6250
6250
6250
6250
3.9
4.2
3.9
4.2
3.9
4.2
Double Rotary DC Inverter
R-410A Electric expansion valve 53.6
55.1
57.1
58.7
59.2
59.0
52.7
55.4
57.9
57.9
57.6
57.8
900
900
900
900
900
900
1327
1327
1327
1327
1327
1327
400
400
400
400
400
400
99
115
99
115
99
115
Ø9.5 (3/8”) Ø15.9(5/8”) 2/50
2/50
2/50
2/50
2/50
2/50
30
30
30
30
30
30
25
25
25
25
25
25
KIT KHP BI 16 TN
KIT KHP BI 16 VN
KIT KHP BI 16 TN
-20~35 -5~46 -20~43 KIT KHP BI 16 VN
KIT KHP BI 16 TN
KIT KHP BI 16 VN
99
DOMESTIC HOT WATER RANGE INTEGRATED SYSTEM
AQUANTIA BIBLOC INDOOR UNIT TECHNICAL SPECIFICATIONS
MODEL
KIT KHP BI 8 VN
Power
Water outlet temperature ranges
Dimensions
Weight Water pipe connections diameter Safety valve
V/ph/Hz
220-240/1/50
KIT KHP BI 16 VN KIT KHP BI 16 TN 220-240/1/50
Heat
ºC
25 ~ 60
Cold
ºC
5 ~ 25
DOMESTIC HOT WATER
ºC
40 ~ 60
H
mm
865
Width
mm
400
Depth
mm
427
Kg
43
mm (inch)
L
Volume of expansion tank
L
0.3 4.7
5
Plates
Water pump pressure
mca (kPa)
Refrigerant circuit diameter (liquid)
mm (inch)
9.5(3/8)
Refrigerant circuit diameter (gas)
mm (inch)
15.9(5/8)
100
5
3
Heat exchanger type
Standard support heater
54
25(1")
Mpa
Total water volume
54
380-415/3/50
kW
6(×58.4)
3
7.5(×73.55)
3
7.5(×73.5)
4.5
R-410A
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
ACS
GENERAL CHARACTERISTICS HEATING An integrated system that provides heating, climate control and domestic hot water to your home. It can generate energy totally independently using its heat pump, or draw on other sources (solar energy, boilers, etc.) already installed. • DC ventilator and compressor. • Climate control and domestic hot water from a single piece of equipment. • It can operate on its own or draw on other energy sources already installed. • A hydraulic system in an indoor unit and a heat pump in an outdoor unit.
+ + + +
RADIATORS
FANCOILS
COMBINATION OF THE ABOVE
CLIMATE CONTROL
+ + +
AQUANTIA BIBLOC
UNDERFLOOR HEATING
FANCOILS
COLD FLOOR
COMBINATION OF THE ABOVE
DOMESTIC HOT WATER
+
ACCUMULATION TANKS
TOUCH CONTROL SMART, ADAPTABLE SYSTEM EASY INSTALLATION, MINIMAL MAINTENANCE POMPE À CHALEUR
WIDE RANGE OF OPERATING TEMPERATURES
101
DOMESTIC HOT WATER RANGE TANKS FOR DOMESTIC HOT WATER
TANKS FOR DOMESTIC HOT WATER TECHNICAL SPECIFICATIONS
MODEL Capacity
L.
Heat Exchanger type
Dimensions
BSX160
BSX190
BSX270
160
190
270
Heat coil
Heat coil
Heat coil
Height
mm
1124
1315
1209
Diameter
mm
Ø 590
Ø 590
Ø 700
Floor including front cover
mm
630
630
740
Kg
104
123
136
Net weight Upper heat coil entrance diameter
Inches
-
-
-
Upper heat coil exit diameter
Inches
-
-
-
m2
-
-
-
Lower heat coil entrance diameter
Inches
1"
1"
1"
Lower heat coil exit diameter
Inches
1"
1"
1"
m2
1.21
1.85
2.48
Cold water inlet
Inches
3/4”
3/4”
1"
Heat water outlet
Inches
3/4”
3/4”
1"
Circulation
Inches
3/4”
3/4”
1"
mm
280
280
280
Area of upper heat coil
Area of lower heat coil
Cleaning cap Tank protective cap material
Steel
Interior cover
Coat of enamel
Exterior cover
Galvanized steel with electrostatic coating with powdered paint.
Casing colour
White
Plugs and exterior cap material Insulating material and thickness Input of sensors for the automatic control of the unit
Black coloured plastic
mm
Injected polyurethane foam, 50 mm
Ø / depth (mm)
3 units, Ø13 x 100
Operating pressure
bar
10
10
10
Test pressure
bar
13
13
13
Temperature indicator Anti-corrosive protection
102
Analogue thermometer Magnesium anode rod and tester
ACS
MODEL Capacity
L.
Heat Exchanger type
Dimensions
BS475
KAYSUN G-751
475
750
Heat coil
Heat coil
Height
mm
1800
2010
Diameter
mm
Ø 750
Ø 940
Floor including front cover
mm
790
1000
Kg
192
285
Net weight Upper heat coil entrance diameter
Inches
-
-
Upper heat coil exit diameter
Inches
-
-
m2
-
-
Area of upper heat coil Lower heat coil entrance diameter
Inches
1 1/4"
1 1/4"
Lower heat coil exit diameter
Inches
1 1/4"
1 1/4"
2.13
4.87
Area of lower heat coil
m2
Cold water inlet
Inches
1"
1 1/4"
Heat water outlet
Inches
1"
1 1/4"
Circulation
Inches
1"
1 1/4"
280
DN200
Coat of enamel
Low carbon steel
Interior cover
Steel
Double coat of vitrified Enamel
Exterior cover
Galvanised steel with electrostatic coating with powdered paint.
Soft PVC coating
Casing colour
White
Yellow
Cleaning cap
mm
Tank protective cap material
Plugs and exterior cap material Insulating material and thickness Input of sensors for the automatic control of the unit
Black coloured plastic
mm Ø / depth (mm)
Injected polyurethane foam, 50 mm 3 units, Ø13 x 100
1 units 1/2”
Operating pressure
bar
10
9
Test pressure
bar
13
18
Temperature indicator Anti-corrosive protection
Analogue thermometer Magnesium anode rod and tester
103
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
DOMESTIC HOT WATER RANGE TANKS FOR DOMESTIC HOT WATER
TANKS FOR DOMESTIC HOT WATER TECHNICAL SPECIFICATIONS
MODEL
KAYSUN G-1001 KAYSUN G-1002 KAYSUN G-1501 KAYSUN G-2001
Capacity
L.
Heat Exchanger type
Dimensions
1000
1000
1500
2000
Heat coil
Double heat coil
Heat coil
Heat coil
Height
mm
2015
2015
2050
2060
Diameter
mm
Ø 1000
Ø 1000
Ø 1200
Ø 1350
Floor including front cover
mm
1065
1065
1300
1450
Kg
340
350
520
570
Net weight Upper heat coil entrance diameter
Inches
-
1 1/4"
-
-
Upper heat coil exit diameter
Inches
-
1 1/4"
-
-
m2
-
1.8
-
-
Area of upper heat coil Lower heat coil entrance diameter
Inches
1 1/4"
1 1/4"
1 1/4"
1 1/4"
Lower heat coil exit diameter
Inches
1 1/4"
1 1/4"
1 1/4"
1 1/4"
m2
5.06
3.86
6.83
7.52
Cold water inlet
Inches
1 1/4"
1 1/4"
1 1/4"
1 1/4"
Heat water outlet
Inches
1 1/4"
1 1/4"
1 1/4"
1 1/4"
Circulation
Inches
1 1/4"
1 1/4"
1 1/4"
1 1/4"
mm
DN200
DN200
DN400
DN400
Area of lower heat coil
Cleaning cap Tank protective cap material
Low carbon steel
Interior cover
Double coat of vitrified Enamel
Exterior cover
Soft PVC coating
Casing colour
Yellow
Plugs and exterior cap material Insulating material and thickness Input of sensors for the automatic control of the unit
Black coloured plastic
mm Inches
Insulating foam, 75 mm 1 unit 1/2”
2 units 1/2" each
1 unit 1/2”
2 units 1/2" each
Operating pressure
bar
9
9
9
9
Test pressure
bar
18
18
18
18
Temperature indicator Anti-corrosive protection
104
Analogue thermometer Magnesium anode rod and tester
ACS
GENERAL CHARACTERISTICS
The Aquatix range is fitted with tanks for domestic hot water and underfloor heating. These tanks are an ideal complement for Aquantia systems.
• Optional 2kW supplementary heater with thermostat.
When there are two heat coils available, the upper heat coil is connected to a domestic hot water heat pump, while the other heat coil can be used for hot water from a solar thermal system or a conventional boiler.
• Analogue thermometer to know the temperature of the upper side of the tank.
• Magnesium protection anode to avoid internal corrosion of the tank. Malfunction test included.
• 1-2 heat coils available inside the unit.
BS AND BSX DEPOSIT
DEPOSIT G (1 HEAT COIL)
DEPOSIT G (2 HEAT COILS)
ACCESSORY RT1, heater of 2 kW with thermostat for models GRT2, heater of 2 kW with thermostat for models B-
105
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
DOMESTIC HOT WATER RANGE ACCUMULATORS
COMPAK
POMPE À CHALEUR
TECHNICAL SPECIFICATIONS MODEL Power
COMPAK KHP 15 190 ACS1
COMPAK KHP 35 300 ACS1
220-240/1/50
220-240/1/50
Economy
Economy
ºC
-7~43
-7~43
kW
1.45
3
1.25
2.58
0.38
0.80
3.8
3.83
A
2.3
4.1
m3/h
0.043
0.086
kW
3.15
3.15
Double
Double
Kg
1
1.2
ºC
Default 60ºC (Adjustable: 38ºC-70ºC)
V/ph/Hz
Operation mode Room temperature Heating Capacity
kCal/h TECHNICAL SPECIFICATIONS
Nominal input
kW
COP Rated current Water flow Electrical heater Compressor type Amount of R-134A refrigerant Evaporator material
Hydrophilic aluminium fin, inner-grooved copper tube
Output water temperature Heat exchanger
Water pipeline
Copper tubing around the tank
Water inlet
mm
DN 20
DN 20
Water outlet
mm
DN 20
DN 20
Drainage pipe
mm
DN 20
DN 20
Safety valve
mm
DN 20
DN 20
Max. Pressure
MPa
1
1
mm
Ø568x1760
Ø650x1920
l
180
280
Kg
107
145.5
dB (A)
41.2
45
mm
ø160
ø190
Static Pressure
Pa
25
25
Max. Length
m
10
10
m3/h
270/230/182
414/355/312
Yes
Yes
Dimension Tank volume Net weight Sound Pressure Level Diameter Air intake and outlet
Outdoor airflow Anti-Legionella function
Rated capacities based on the following conditions: Outdoor temperature 15/12ºC (dry bulb / wet bulb), water inlet / outlet 15/45ºC. Sound pressure at 1 meter distance from the unit.
106
Default 55ºC (Adjustable: 38ºC-65ºC)
R-134A
ACS
GENERAL CHARACTERISTICS Domestic hot water storage or underfloor heating using heat pump technology. Provides water temperatures of up to 70ºC. It is fitted with a condenser located around the tank to avoid contact between refrigerant and sanitary hot water. It also includes a magnesium protection anode to avoid internal corrosion of the tank. • Compact design and easy installation. • LCD screen control display. • They must be protected against solar radiation. • Built-in relief valve. • Non-programmable hybrid mode.
COMPAK KHP 15 190 ACS1
OPERATION MODE
+ + + +
ECONOMY: only the heating pump operates
ELECTRICAL HEATER for additional heating
HYBRID: use of the heat pump + heater
MAGESIUM ANODE in all models
COMPAK KHP 35 300 ACS1
PRICE LIST MODEL COMPAK KHP 15 190 ACS1 COMPAK KHP 35 300 ACS1
107
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
DOMESTIC HOT WATER RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
RAFA NADAL INTERNATIONAL CENTRE PUBLIC BUILDING Location: Balearic Islands Initial situation: New construction Units installed: Aquatix Systems Capacity: 7 kW
108
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
109
DOMESTIC HOT WATER RANGE KEY INSTALLATIONS
AQUATIX IS A MORE SUSTAINABLE SOLUTION THAN THE TRADITIONAL HOT WATER BOILER, WITH BETTER ENERGY EFFICIENCY AND A QUICKER AND MORE SIMPLE INSTALLATION PROCESS. ENERGY SAVINGS AND EFFICIENCY SET THIS RANGE APART.
ON HOTELS OCEANFRONT HOTEL
Location: Matalascañas Initial situation: Renovation Units installed: 2 KHP 420 ACS1 Capacity: 80 kW
110
RUBER HOSPITAL
ITEVE
PUBLIC BUILDING
BUSINESS CENTRE
Location: Madrid Initial situation: Renovation Units installed: AIR-WATER Capacity: 130 kW
Location: Badajoz (Extremadura) Initial situation: Renovation Units installed: Compak KHP Capacity: 245 kW
QUIRÃ&#x201C;N HOSPITAL
INSTITUTION ST. LOUIS
PUBLIC BUILDING
SCHOOL
Location: Torrevieja Initial situation: New construction Units installed: AIR-WATER Capacity: 65 kW
Location: France Initial situation: Renovation Units installed: KHP 72 ACS + G1 Capacity: 6.5 kW
JARDINES DE LORCA
SYNERGYM
HOTEL
GYM
Location: Murcia Initial situation: New construction Units installed: AIR-WATER Capacity: 260 kW
AQUATIX DOMESTIC HOT WATER
Inspiration, Innovation, Evolution
Location: GYM Initial situation: Renovation Units installed: 5 KHP 35 300 ACS1 Capacity: 18 kW
111
ZEN R-410A COMMERCIAL RANGE
INTRODUCTION TO THE PRODUCT RANGE............................................114 SETS.............................................................................................................116 CASSETTE (600X600)..........................................................................118 SUPERSLIM CASSETTE.......................................................................120 FLOOR / CEILING............................................................................... ..124 DUCTS...................................................................................................128 FLOOR STANDING............................................................................. ..132 TWINS....................................................................................................... ..134 KEY INSTALLATIONS............................................................................... 136
ZEN R-410A COMMERCIAL
ZEN
R-410A COMMERCIAL RANGE
R-410A COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
ZEN
R-410 COMMERCIAL RANGE
“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”
Introducing the KAYSUN commercial range with axial and centrifugal outdoor fans with R-410A refrigerant. The most outstanding features of the axial outdoor fans fitted in this range are: advanced technology, efficiency, versatility and high performance. Regarding centrifugal outdoor fans , we could say that their main feature is adaptability. This unit is perfect for indoor spaces with no room for an axial outdoor fan.
The combination systems with outdoor centrifugal units are pieces of equipment with a compressor and indoor ventilators with DC Inverter technology. These units with a centrifugal ventilator embody one of our key principles (versatility) and have been created to provide a customised solution that is suited to the need to integrate them into the facade of street premises.
Combination systems with axial outdoor units are fitted with Inverter technology ,thereby, optimising energy efficiency and seasonal performance indicators with a SCOP 4.0.. The outdoor units of this type have an aesthetic with a robust design and good sound performance.
Within the ZEN we have a wide variety of indoor units: Compact Cassette (600x600), Superslim Cassette (840x840), Floor/ Ceiling units and, our new product, Ducts systems. Some of these units can be installed in a TWINS configuration: one outdoor unit with two indoor units working together.
AXIAL OUTDOOR UNITS We wish to highlight the axial outdoor units of Kaysun’s Zen range. These units designed to make maintenance tasks easier and protect its main components in order to extend the life cycle of the product.
+ +
R-410A
+
STRONGER AND COMPACT
PERFORMANCE
ENERGY SAVING
SOUND LEVEL
CENTRIFUGAL OUTDOOR UNITS The centrifugal outdoor units offered by KAYSUN are a highly recommended option for systems where there is no outdoor space for installation.
R-410A
+ + +
114
14 AND 16 KW
FLEXIBLE CONFIGUATION CONDENSATION AIR INLET AND OUTLET 60 PA AVAILABLE PRESURE
Inspiration, Innovation, Evolution
DUCT UNIT
NEW
• Removable filter (it can be extracted without touching the unit). • Flange for fitting the outlet duct. • Flange for fitting the intlet (return) duct. • Double return system possibility rear or lower inlet. • Condensation pump. • Pre-installation for fresh air inlet. • Electric box removable up to 1 metre apart from the unit's body.
R-410A
• On/Off and Alarm dry contacts. • The KC-03.1 SPS controller allows adjusting the available pressure automatically. • Up to 160 Pa available depending on the model. • Horizontal and vertical installation. • Reduced height unit.
Compatible with
TWO COMMUNICATION WIRES
x2
The ZEN range units* only require two shielded wires without polarity to carry out the operation. This new characteristic makes the communication wiring works cheaper and easier. *Except for 3.5 kW unit.
K03 WIFI LCAC
NEW
has an optional WiFi adapter for some of its indoor unit models in the ZEN range. This accessory, connect the unit to our domestic WiFi network and control it through an App installed on our Smartphone. The application also includes a weekly timer built into the App to ease and improve the control function of our air-conditioning system.
S1 S2
S1 S2
115
ZEN R-410A COMMERCIAL
With regard to the indoor units of the ZEN RANGE,we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:
R-410A COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
CASSETTE R-410A
116
Inspiration, Innovation, Evolution
POWER kW
3.5
5.2
7.1
9.0
10.5
12.5
14.0
16.0
SETS CASSETTE (600 X 600) KCI-52 DVN10
ZEN R-410A COMMERCIAL
KCI-35 DVN11
(Page 118)
SUPERSLIM CASSETTE AXIAL OUTDOOR UNIT KCIS-52 DVN11
(Page 122)
KCIS-71 DVN11
CENTRIFUGAL OUTDOOR UNIT
KCIS-90 DVN10
KCIS-105 DVN11 KCIS-125 DVN10 KCIS-140 DVN11 KCIS-105 DTN11 KCIS-125 DTN10 KCIS-140 DTN11
KCIS-160 DTN11
(Page 121) KCISC-140 DTN11 KCISC-160 DTN11
FLOOR / CEILING AXIAL OUTDOOR UNIT KPC-52 DVN11
(Page 126) KPC-71 DVN11
CENTRIFUGAL OUTDOOR UNIT
KPC-90 DVN10
KPC-105 DVN11 KPC-125 DVN10 KPC-105 DTN11 KPC-125 DTN10
KPC-140 DVN11 KPC-140 DTN11
KPC-160 DTN11
(Page 125) KPCC-140 DTN11 KPCC-160 DTN11
Ducts
NEW
AXIAL OUTDOOR UNIT KPD-35 DVN11
KPD-52 DVN11
(Page 130)
KPD-71 DVN11
CENTRIFUGAL OUTDOOR UNIT
KPD-90 DVN11
KPD-105 DVN11 KPD-125 DVN10 KPD-140 DVN11 KPD-105 DTN11 KPD-125 DTN10 KPD-140 DTN11
KPD-160 DTN11
(Page 129) KPDC-140 DTN11 KPDC-160 DTN11
FLOOR STANDING AXIAL OUTDOOR UNIT
UNTIL END OF STOCK
(Page 133) KPV-140 DVN10 KPV-140 DTN10
CENTRIFUGAL OUTDOOR UNIT
(Page 133) KPVC-140 DTN10
117
R-410A COMMERCIAL RANGE CASSETTE SETS (600X600)
CASSETTE (600x600) GENERAL CHARACTERISTICS
The Cassette Artflux 360º 600x600 units stands out from other units thanks to its elegant design. Their small dimensions allows them for adapting to false ceiling installations and their 360º air flow provides user with highest comfort and covers every corner of the room.
•
Pre-installed inlet for fresh air.
•
Compact unit with integrated electric box.
•
Standard condensation pump.
•
Voltage-free alarm and ON/OFF dry contacts.
•
The 5.2 kW unit is compatible with TWINS configuration.
•
360º airflow.
+
STANDARD CONDENSATION PUMP
KID-02 S (*) RECOMMENDED
NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers Range
INDIVIDUAL
KID-02 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KC-02.1 H
KC-01 S
KCT-02.1 SR
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
118
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
4.0 R-410A
x2
SCOP
50/60 Hz
!
AXIAL SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./rated/max.) Heating capacity (min./rated/max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC
kW Kcal/h W
kW Kcal/h W
kW
INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Width/Height/Depth (panel) Net weight (panel) Power wiring Shielded communication wires*** Power supply
m /h dB (A) mm Kg mm Kg mm2 mm2 V / F / Hz 3
AXIAL OUTDOOR UNIT Compressor type Outdoor airflow Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires*** Power supply
m3/h dB (A) gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
KCI-35 DVN11
KCI-52 DVN10
0.85/3.52/4.13
0.79/5.28/6.15
731/3027/3552
679/4540/5288
168/1080/1539
0.270/1.630/2.365
6.1
6.3
A++
A++
0.47/4.1/4.41
0.88/5.57/7.03
404/3526/3793
757/4789/6045
124/1060/1361
0.295/1.500/2.510
4.0
4.0
A+
A+
3.18
4.25
3.08
2.77
KCI-35 DR11
KCI-52 DN10
617/504/416
660/550/490
35
38
570/260/570
570/260/570
16.2
16.5
647/50/647
647/50/647
2.5
2.5
with communication
(2+T)x2.5
(3+T)x2.5
2x1.5
220-240/1/50
220-240/1/50
KUE-35 DVN11
KUE-52 DVN10
Rotary
Rotary
2000
2100
56
56.5
R-410A
R-410A
1050 / 15
1780 / 15
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
ø12.7 (1/2")
25
30
10
20
800/554/333
800/554/333
29.9
35.5
(2+T)x2.5
(2+T)x2.5
(3+T)x2.5
2x1.5
220-240/1/50
220-240/1/50
ZEN R-410A COMMERCIAL
TECHNICAL SPECIFICATIONS
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. *** Except for 35 (3.5 kW) models. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
119
R-410A COMMERCIAL RANGE SUPERSLIM CASSETTE TYPE SETS
SUPERSLIM CASSETTE GENERAL CHARACTERISTICS In order to provide users with maximum comfort, the cassette units are fitted with a 360° air diffusion system that allows them to reach every corner of the room. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings. •
Outdoor air intake pipeline assembly (optional).
•
Slim design compact unit.
•
Standard condensation pump.
•
Alarm and ON/OFF dry contacts.
•
Louvers position storage.
•
360º airflow.
•
Units 52, 71 and 90 are compatible with TWINS configuration.
•
Prepared for side ducts (closing air outlets).
+
TWINS COMBINATIONS (OPTIONAL)
+
STANDARD CONDENSATION PUMP
KID-02 S (*) RECOMMENDED
NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY Compatible with DR11 units. UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
CENTRALISED
KCCT-64 I (B)
KID-02 S
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
120
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
x2
R-410A
DC
!
DC INDOOR
CENTRIFUGAL SET Cooling capacity Cooling capacity Cooling input Heating Capacity Heating Capacity Heating input Heating capacity -7ºC
kW Kcal/h kW kW Kcal/h kW kW
INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Width/Height/Depth (panel) Net weight (panel) Power wiring Shielded communication wires Power supply
m /h dB (A) mm Kg mm Kg mm2 mm2 V / F / Hz 3
CENTRIFUGAL OUTDOOR UNITS Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply
KCISC-140 DTN11
KCISC-160 DTN11
12.6
16.11
10836
13855
5.49
6.76
12.89
16.99
11085
14611
4.67
6.13
9
11
KCIS-140 DR11
KCIS-160 DR11
1715/1568/1381
1970/1737/1537
49
48
840/287/840
840/287/840
29
29.7
950/55/950
950/55/950
5
5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
KUEC-140 DTN10
KUEC-160 DTN10
Scroll
Scroll
m3/h / Pa dB (A)
3600/60
3600/60
64
64
R-410A
R-410A
gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
4300/30
4300/30
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
65
30
30
1394/568/783
1394/568/783
177
177
(4+T)x4
(4+T)x4
2x1.5
2x1.5
380-400/3/50
380-400/3/50
ZEN R-410A COMMERCIAL
TECHNICAL SPECIFICATIONS
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
121
R-410A COMMERCIAL RANGE SUPERSLIM CASSETTE TYPE SETS
SUPERSLIM CASSETTE TECHNICAL SPECIFICATIONS AXIAL SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./nom./max.) Heating capacity (min./nom./max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC
kW Kcal/h kW
kW Kcal/h kW
kW
INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Width/Height/Depth (panel) Net weight (panel) Power wiring Shielded communication wires Power supply
m3/h dB (A) mm Kg mm Kg mm2 mm2 V / F / Hz
AXIAL OUTDOOR UNIT Compressor type Outdoor airflow Sound pressure Refrigerant Refrigerant charge / Additional charge** Liquid pipe Liquid Liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply
m /h dB (A) 3
gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
KCIS-52 DVN11
KCIS-71 DVN11
KCIS-90 DVN10
KCIS-105 DVN11
0.79/5.28/6.15
1.20/7.03/8.21
2.08/8.79/10.55
2.93/10.55/12.09
679/4540/5289
1032/6045/7061
1789/7559/9073
2520/9073/10397
0.26/1.68/2.36
0.40/2.17/3.15
0.69/2.76/4.05
0.97/4.06/4.62
6.3
6.1
6.1
6.1
A++
A++
A++
A++
0.88/5.67/7.03
1.20/7.20/8.65
2.08/9.08/10.52
2.64/11.13/13.19
757/4876/6046
1032/6192/7439
1789/7809/9047
2296/9572/11343
0.29/1.46/2.51
0.40/2.05/3.09
0.69/2.38/3.75
0.88/3.08/4.69
4.0
4.0
4.0
4.0
A+
A+
A+
A+
4.33
5.13
6.99
8.76
2.52
2.53
2.50
2.48
KCIS-52 DR11
KCIS-71 DR11
KCIS-90 DN10
KCIS-105 DR11
1036/867/763
1378/1200/1032
1700/1460/1300
1775/1620/1438
37
40
44
46
840/205/840
840/245/840
840/245/840
840/245/840
21.4
23
26.5
27.5
950/55/950
950/55/950
950/55/950
950/55/950
5
5
5
5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KUE-52 DVN10
KUE-71 DVN10
KUE-90 DVN10
KUE-105 DVN10
Rotary
Double rotary
Double rotary
Double rotary
2100
2700
4300
4300
56.5
60.5
59.5
61
R-410A
R-410A
R-410A
R-410A
1780 / 15
1950 / 30
2800 / 30
3200 / 30
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
30
50
50
65
20
25
25
30
800/554/333
845/702/363
946/810/410
946/810/410
35.5
49
62.9
67.2
(2+T)x2.5
(2+T)x2.5
(2+T)x4
(2+T)x4
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
122
Inspiration, Innovation, Evolution
4.0 SCOP
R-410A
x2
50/60 Hz
!
KCIS-105 DTN11
KCIS-125 DVN10
KCIS-125 DTN10
KCIS-140 DVN11
KCIS-140 DTN11
KCIS-160 DTN11
2.93/10.55/12.02
3.22/12.31/13.19
3.22/12.31/13.19
3.99/14.07/16.12
3.99/14.07/16.12
4.98/15.53/18.46
2520/9073/10337
2769/10586/11343
2769/10586/11343
3431/12100/13863
3431/12100/13863
4282/13356/15875
0.97/4.06/4.62
1.07/4.09/5.07
1.07/4.09/5.07
1.33/5.39/6.20
1.33/5.39/6.20
1.66/6.40/7.10
6.1
5.6
5.6
5.6
5.6
5.6
A++
A+
A+
A+
A+
A+
2.64/11.13/13.19
2.93/13.48/14.65
3.4/12.89/14.5
4.19/16.12/17.59
4.19/16.12/17.59
5.28/18.17/20.51
2296/9572/11343
2520/11593/12599
2924/11085/12470
3603/13863/15127
3603/13863/15127
4540/15626/17638
0.88/3.08/4.69
0.97/3.53/5.23
0.97/3.53/5.23
1.40/5.35/6.76
1.40/5.35/6.76
1.76/5.73/7.32
4.0
4.0
4.0
4.0
4.0
4.0
A+
A+
A+
A+
A+
A+
8.93
9.73
9.73
10.17
10.17
10.17
2.44
2.75
2.78
2.29
2.60
2.66
KCIS-105 DR11
KCIS-125 DN10
KCIS-125 DN10
KCIS-140 DR11
KCIS-140 DR11
KCIS-160 DR11
1775/1620/1438
1850/1600/1400
1850/1600/1400
1715/1568/1381
1715/1568/1381
1970/1737/1537
46
48
48
49
49
48
840/245/840
840/287/840
840/287/840
840/287/840
840/287/840
840/287/840
27.5
26.1
26.1
29
29
29.7
950/55/950
950/55/950
950/55/950
950/55/950
950/55/950
950/55/950
5
5
5
5
5
5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KUE-105 DTN10
KUE-125 DVN10
KUE-125 DTN10
KUE-140 DVN10
KUE-140 DTN10
KUE-160 DTN10
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
4300
4300
4300
6800
6800
7200
62
62.5
63
65
65
62.5
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
3200 / 30
3650 / 30
3650 / 30
4000 / 30
4000 / 30
4300 / 30
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8") 65
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
ø15.9 (5/8") 65
65
65
65
30
30
30
30
30
30
946/810/410
946/810/410
946/810/410
952/1333/415
952/1333/415
952/1333/415
78.9
70.5
85
95.1
108.1
112.8
(4+T)x2.5
(2+T)x4
(4+T)x2.5
(2+T)x6
(4+T)x4
(4+T)x6
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
380-400/3/50
220-240/1/50
380-400/3/50
220-240/1/50
380-400/3/50
380-400/3/50
123
ZEN R-410A COMMERCIAL
UNTIL END OF STOCK
R-410A COMMERCIAL RANGE FLOOR / CEILING SETS
FLOOR / CEILING GENERAL CHARACTERISTICS
Kaysun Zen range makes air conditioning at your disposal through its most versatile product, the Floor/Ceiling units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit compatible with centrifugal outdoor units. •
Easy access to components for maintenance.
•
Improved airflow for a greater comfort.
•
FLOOR or CEILING installation.
•
Voltage-free alarm and ON/OFF dry contacts.
•
New numerical display in the receiver.
•
Optional wired controller.
+
COMPATIBLE WITH WALL-MOUNTED / CEILING UNITS
ALARM AND ON/OFF DRY CONTACTS
+
NEW KID-02 S
OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
(*) RECOMMENDED
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers Range
INDIVIDUAL
KID-02 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KC-03.1 SPS
KC-03 SPS
KC-02.1 H
KC-01 S
KCT-02.1 SR
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
124
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
R-410A
x2
DC
!
DC
CENTRIFUGAL SET Cooling capacity Cooling capacity Cooling input Heating Capacity Heating Capacity Heating input Heating capacity -7ºC
kW Kcal/h kW kW Kcal/h kW kW
INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/height/depth (ceiling installation) Net weight Power wiring Shielded communication wires Power supply
m3/h dB (A) mm Kg mm2 mm2 V / F / Hz
CENTRIFUGAL OUTDOOR UNITS Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply
m /h / Pa dB (A) 3
gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
KPCC-140 DTN11
KPCC-160 DTN11
13.5
16
11610
13760
5.885
6.891
14.65
17
12599
14620
5.657
6.468
9.82
10.88
KPC-140 DR11
KPC-160 DR11
2329/1930/1417
2454/1834/1426
46
42
1650/235/675
1650/235/675
41.2
41.4
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
KUEC-140 DTN10
KUEC-160 DTN10
Scroll
Scroll
3600/60
3600/60
64
64
R-410A
R-410A
4300 / 30
4300 / 30
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
65
30
30
1394/568/783
1394/568/783
177
177
(4+T)x4
(4+T)x4
2x1.5
2x1.5
380-400/3/50
380-400/3/50
ZEN R-410A COMMERCIAL
TECHNICAL SPECIFICATIONS
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
125
R-410A COMMERCIAL RANGE FLOOR / CEILING SETS
FLOOR / CEILING TECHNICAL SPECIFICATIONS KPC-52 DVN11
AXIAL SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./rated/max.) Heating capacity (min./rated/max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC
kW Kcal/h kW
kW Kcal/h kW
kW
INDOOR UNIT
Indoor airflow Sound pressure (low speed) Width/height/depth (ceiling installation) Net weight Power wiring Shielded communication wires Power supply
m3/h dB (A) mm Kg mm2 mm2 V / F / Hz
KPC-105 DVN11
0.79/5.28/6.15
1.2/7.03/8.21
2.08/8.79/10.55
2.93/10.55/12.02
679/4541/5289
1032/6046/7061
1789/7559/9073
2520/9073/10337
0.27/1.63/2.37
0.4/2.29/3.16
0.69/2.96/4.06
0.98/4.06/4.62
6.5
6.1
6.1
6.3
A++
A++
A++
A++
0.88/5.67/7.03
1.2/7.62/8.65
2.08/9.38/10.84
2.64/11.13/13.19
757/4876/6046
1032/6553/7439
1789/8067/9322
2270/9572/11343
0.26/1.46/2.51
0.4/2.05/3.09
0.69/2.48/3.87
0.88/2.99/4.69
4.0
4.0
4.0
4.0
A+
A+
A+
A+
4.33
5.13
7.25
9.29
2.61
2.64
2.53
2.48
KPC-52 DR11
KPC-71 DR11
KPC-90 DN10
KPC-105 DR11
902/786/677
1208/1066/853
1650/1450/1250
2160/1844/1431
37
41
44
42
1068/235/675
1068/235/675
1285/235/675
1650/235/675
26.6
26.8
31
40.3
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KUE-71 DVN10
KUE-90 DVN10
KUE-105 DVN10
Rotary
Double rotary
Double rotary
Double rotary
m3/h dB (A)
2100
2700
4300
4300
56.5
60.5
59.5
61
R-410A
R-410A
R-410A
R-410A
gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
1780 / 15
1950 / 30
2800 / 30
3200 / 30
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
30
50
50
65
20
25
25
30
800/554/333
845/702/363
946/810/410
946/810/410
35.5
49
62.9
67.2
(2+T)x2.5
(2+T)x2.5
(2+T)x4
(2+T)x4
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
126
KPC-90 DVN10
KUE-52 DVN10
AXIAL OUTDOOR UNIT Compressor type Outdoor airflow Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply
KPC-71 DVN11
Inspiration, Innovation, Evolution
4.0 R-410A
x2
SCOP
50/60 Hz
!
UNTIL END OF STOCK
KPC-125 DVN10
KPC-125 DTN10
KPC-140 DVN11
KPC-140 DTN11
KPC-160 DTN11
2.93/10.55/12.02
3.22/12.31/13.19
3.22/12.31/13.19
4.1/14.07/16.41
4.1/14.07/16.41
4.98/15.82/18.11
2520/9073/10337
2769/10587/11343
2769/10587/11343
3526/12100/14113
3526/12100/14113
4283/13605/15575
0.98/4.06/4.62
1.07/4.23/5.07
1.07/4.23/5.07
1.37/5.19/6.31
1.37/5.19/6.31
1.66/6.06/6.97
6.1
6.1
6.1
6.1
6.1
6.1
A++
A++
A++
A++
A++
A++
2.64/11.13/13.19
3/13.5/14.7
2.84/12.9/14.01
4.4/16.12/18.46
4.4/16.12/18.46
5.28/18.17/20.51
2270/9572/11343
2580/11610/12642
2442/11103/12049
3784/13863/15876
3784/13863/15876
4541/15626/17639
0.88/2.99/4.69
0.95/3.54/5
0.95/3.54/5
1.47/4.07/6.59
1.47/4.07/6.59
1.76/5.65/7.32
4.0
4.0
4.0
4.0
4.0
4.0
A+
A+
A+
A+
A+
A+
9.11
9.73
9.73
10.44
10.44
10.62
2.43
2.61
2.73
2.54
2.71
2.76
KPC-105 DR11
KPC-125 DN10
KPC-125 DN10
KPC-140 DR11
KPC-140 DR11
KPC-160 DR11
2160/1844/1431
2271/1886/1394
2100/1800/1400
2329/1930/1417
2329/1930/1417
2454/1834/1426
42
43
41
46
46
45
1650/235/675
1650/235/675
1650/235/675
1650/235/675
1650/235/675
1650/235/675
40.3
40.5
40.5
41.2
41.2
41.4
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KUE-105 DTN10
KUE-125 DVN10
KUE-125 DTN10
KUE-140 DVN10
KUE-140 DTN10
KUE-160 DTN10
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
4300
4300
4300
6800
6800
7200
62
62.5
63
65
65
62.5
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
3200 / 30
3650 / 30
3650 / 30
4000 / 30
4000 / 30
4300 / 30
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8") 65
ø15.9 (5/8") 65
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
65
65
65
30
30
30
30
30
30
946/810/410
946/810/410
946/810/410
952/1333/415
952/1333/415
952/1333/415
78.9
70.5
85
95.1
108.1
112.8
(4+T)x2.5
(2+T)x4
(4+T)x2.5
(2+T)x6
(4+T)x4
(4+T)x6
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
380-400/3/50
220-240/1/50
380-400/3/50
220-240/1/50
380-400/3/50
380-400/3/50
127
ZEN R-410A COMMERCIAL
KPC-105 DTN11
R-410A COMMERCIAL RANGE DUCTS SETS
Ducts
NEW
GENERAL CHARACTERISTICS The new Kaysun ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design. •
Easily removable filter.
•
Up to 160 Pa available depending on the model.
•
Flanges in the inlet and outlet mouth.
•
Standard condensation pump of up to 750 mm in height.
•
Possibility for double air intake (rear or lower intake).
•
•
Fresh air intake at a side of the unit.
The KC-03.1 SPS controller allows adjusting the available pressure automatically.
•
Voltage-free alarm and ON/OFF dry contacts.
•
Horizontal and vertical installation.
Electric box removable up to 1 metre apart from the unit's body.
•
Reduced height unit.
•
+ +
STANDARD CONDENSATION PUMP up to 750 mm HEIGHT
VERTICAL INSTALLATION (OPTIONAL)
Compatible with
NEW KC-03.1 SPS
OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
(*) RECOMMENDED
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
For further information, please see our Controllers Range
INDIVIDUAL
KID-02 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KC-03.1 SPS
KC-03 SPS
KC-02.1 H
KC-01 S
KCT-02.1 SR
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
128
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
x2
R-410A
DC
!
DC
TECHNICAL SPECIFICATIONS
Cooling capacity Cooling capacity Cooling input Heating Capacity Heating Capacity Heating input Heating capacity -7ºC
kW Kcal/h kW kW Kcal/h kW kW
INDOOR UNIT Air flow Maximum pressure available Sound pressure (low speed) Width/Height/Depth Net weight Power wiring Shielded communication wires Power supply
m /h Pa dB (A) mm Kg mm2 mm2 V / F / Hz 3
CENTRIFUGAL OUTDOOR UNITS Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Inlet liquid pipe Liquid Inlet liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply
m /h / Pa dB (A) 3
gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
KPDC-160 DTN11
13.5
16
11610
13760
5.483
6.281
14.65
17
12599
14620
4.962
5.775
10
12
KPD-140 DR11
KPD-160 DR11
2900/2600/2100
2900/2600/2100
160
160
48
50.5
1200/300/874
1200/300/874
47.6
47.6
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
KUEC-140 DTN10
KUEC-160 DTN10
Scroll
Scroll
3600/60
3600/60
64
64
R-410A
R-410A
4300/30
4300/30
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
65
30
30
1394/568/783
1394/568/783
177
177
(4+T)x4
(4+T)x4
2x1.5
2x1.5
380-400/3/50
380-400/3/50
ZEN R-410A COMMERCIAL
KPDC-140 DTN11
CENTRIFUGAL SET
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
129
R-410A COMMERCIAL RANGE DUCTS SETS
Ducts
NEW
TECHNICAL SPECIFICATIONS KPD-35 DVN11
KPD-52 DVN11
KPD-71 DVN11
KPD-90 DVN11
KPD-105 DVN11
Cooling capacity (min./rated/max.)
kW
0.53/3.52/3.75
1.23/5.28/6.15
1.99/7.03/8.21
2.20/8.79/10.55
2.40/10.55/12.01
Cooling capacity (min./rated/max.)
Kcal/h
456/3027/3225
1058/4541/5289
1711/6046/7061
1892/7559/9073
2064/9073/10329
kW
0.16/1.24/1.6
0.26/1.64/2.12
0.45/2.18/2.80
0.50/2.84/3.20
0.66/4.06/4.38
5.6
6.1
6.1
6.1
6.3
AXIAL SET
Cooling input (min./rated/max.) SEER
A+
A++
A++
A++
A++
Heating capacity (min./rated/max.)
kW
1.00/3.81/3.99
1.80/5.57/7.03
2.40/7.62/8.65
2.70/9.38/10.84
2.78/11.14/13.20
Heating capacity (min./rated/max.)
Kcal/h
860/3277/3431
1548/4790/6046
2061/6553/7439
2322/8067/9322
2391/9580/11352
kW
0.30/1.20/1.40
0.31/1.54/2.15
0.48/2.05/2.85
0.55/2.29/3.25
0.65/3.09/4.40
SCOP
4.0
4.0
4.0
4.0
4.0
Heating efficiency class
A+
A+
A+
A+
A+
2.92
4.16
5.13
7.25
9.29
2.57
2.51
2.68
2.6
2.56
Cooling energy class
Heating input (min./rated/max.)
Heating capacity -7ºC
kW
COP -7ºC
KPD-35 DR11
KPD-52 DR11
KPD-71 DR11
KPD-90 DN11
KPD-105 DR11
m3/h
600/480/300
1000/853/684
1550/1350/1150
2000/1650/1250
2000/1650/1250
Maximum pressure available
Pa
60
100
100
160
160
Sound pressure (low speed)
dB (A)
27.5
40
40
40
40
mm
975/200/450
1055/210/674
1100/249/774
1360/249/774
1360/249/774
INDOOR UNIT Air flow
Width/Height/Depth Net weight
Kg
18
25.6
31.5
40.6
40.5
Power wiring
mm2
with communication
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires***
mm2
(3+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
KUE-35 DVN11
KUE-52 DVN10
KUE-71 DVN10
Rotary
Rotary
Double rotary
Double rotary
Double rotary
Outdoor airflow
3
m /h
2000
2100
2700
4300
4300
Sound pressure
dB (A)
56
56.5
60.5
59.5
61
R-410A
R-410A
R-410A
R-410A
R-410A
gr
1050 / 15
1780 / 15
1950 / 30
2800 / 30
3200 / 30
AXIAL OUTDOOR UNIT Compressor type
Refrigerant Refrigerant charge / Additional charge**
KUE-90 DVN10 KUE-105 DVN10
mm (Inch)
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Inlet liquid pipe Gas
mm (Inch)
ø9.52 (3/8")
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
Max. piping length
m
25
30
50
50
65
Pipe height difference
m
10
20
25
25
30
Width/Height/Depth
mm
800/554/333
800/554/333
845/702/363
946/810/410
946/810/410
Net weight
Kg
29.9
35.5
49
62.9
67.2
Power wiring (10 m max.)
2
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x4
(2+T)x4
Shielded communication wires***
mm2
(3+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Inlet liquid pipe Liquid
Power supply
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. *** Except for 35 (3.5 kW) models. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
130
Inspiration, Innovation, Evolution
4.0 R-410A
x2
SCOP
50/60
!
Hz
KPD-105 DTN11
KPD-125 DVN10
KPD-125 DTN10
KPD-140 DVN11
KPD-140 DTN11
KPD-160 DTN11
2.40/10.55/12.01
3.22/12.31/13.19
3.22/12.31/13.19
4.1/14.07/16.41
4.1/14.07/16.41
4.98/15.82/18.11
2064/9073/10329
2769/10587/11343
2769/10587/11343
3526/12100/14113
3526/12100/14113
4283/13605/15575
0.66/4.06/4.38
1.07/4.09/5.07
1.07/4.09/5.07
1.37/5.12/6.31
1.37/5.12/6.31
1.66/5.26/6.97
6.1
5.6
5.6
6.1
6.1
6.1
A++
A+
A+
A++
A++
A++
2.78/11.14/13.20
2.93/13.48/14.65
2.93/13.48/14.65
4.34/16.12/18.13
4.34/16.12/18.13
5.28/18.17/20.51
2391/9580/11352
2520/11593/12599
2520/11593/12599
3732/13863/15592
3732/13863/15592
4541/15626/17639
0.65/3.09/4.40
0.98/3.54/5.23
0.98/3.54/5.23
1.45/4.36/6.48
1.45/4.36/6.48
1.76/5.03/7.32
4.0
4.0
4.0
4.0
4.0
4.0
A+
A+
A+
A+
A+
A+
9.29
9.73
9.73
10.79
10.79
10.88
2.56
2.75
2.78
2.77
2.71
2.86
KPD-105 DR11
KPD-125 DN10
KPD-125 DN10
KPD-140 DR11
KPD-140 DR11
KPD-160 DR11
2000/1650/1250
2200/1900/1600
2200/1900/1600
2900/2600/2100
2900/2600/2100
2900/2600/2100
160
160
160
160
160
160
40
44
44
48
48
50.5
1360/249/774
1200/300/865
1200/300/865
1200/300/874
1200/300/874
1200/300/874
40.5
43.4
43.4
47.6
47.6
47.6
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KUE-105 DTN10
KUE-125 DVN10
KUE-125 DTN10
KUE-140 DVN10
KUE-140 DTN10
KUE-160 DTN10
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
4300
4300
4300
6800
6800
7200
62
62.5
63
65
65
62.5
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
3200 / 30
3650 / 30
3650 / 30
4000 / 30
4000 / 30
4300 / 30
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
65
65
65
65
65
30
30
30
30
30
30
946/810/410
946/810/410
946/810/410
952/1333/415
952/1333/415
952/1333/415
78.9
70.5
85
95.1
108.1
112.8
(4+T)x2.5
(2+T)x4
(4+T)x2.5
(2+T)x6
(4+T)x4
(4+T)x6
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
380-400/3/50
220-240/1/50
380-400/3/50
220-240/1/50
380-400/3/50
380-400/3/50
131
ZEN R-410A COMMERCIAL
UNTIL END OF STOCK
R-410A COMMERCIAL RANGE FLOOR STANDING SETS
FLOOR STANDING GENERAL CHARACTERISTICS Kaysun Floor Standing units are available with both axial and centrifugal fans. This improves versatility and the possibility to add more indoor units in every installation.
•
Built-in controller.
•
Wireless controller (optional).
•
Easy integration into the room environment.
•
Bottom air intake and upper air discharge.
+
BOTTOM AIR INTAKE / UPPER AIR DISCHARGE
UNIT PRICE CALCULATED BASED ON THE RECOMMENDED CONTROLLER If you want a different control, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
CENTRALISED
KCCT-64 I (B)
KID-02 S
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
132
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
R-410A
TECHNICAL SPECIFICATIONS
kW Kcal/h kW
kW
m3/h dB (A) mm Kg mm2 mm2 V / F / Hz
DC
KPV-140 DVN10
KPV-140 DTN10
KPVC-140 DTN10
3.52/14.07/14.95
3.96/14.07/14.95
13.98
3027/12100/12857
3406/12100/12857
12023
0.46/5.00/5.80
0.46/5.00/5.85
5.20
6.1
6.1
-
A++
A++
-
2.43/14.65/16.41
2.43/14.65/17.0
14
2090/12599/14113
2090/12599/14113
12341
0.45/4.44/5.05
0.45/4.44/5.05
4.64
4.0
-
-
A+
A+
-
9.81
9.81
9.75
2.81
2.81
-
KPV-140 DN10
KPD-140 DN10
KPV-140 DN10
2150/1850/1450
2150/1850/1450
2150/1850/1450
44
44
44
600/1934/455
600/1934/455
600/1934/455
61.6
61.6
61.6
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
2x1.5
2x1.5
2x1.5
220-240/1/50
220-240/1/50
220-240/1/50
KUE-140 DVN10
KUE-140 DTN10
KUEC-140 DTN10
Rotary
Double rotary
Scroll
m3 / h / Pa dB (A)
6800
6800
3600 / 60
65
65
64
R-410A
R-410A
R-410A
gr mm (inch") mm (inch") m m mm Kg mm2 mm2 V / F / Hz
4000 / 30
4000 / 30
4000 / 30
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
65
65
65
30
30
30
952/1333/415
952/1333/415
1394/568/783
95.1
108.1
177
(2+T)x6
(4+T)x4
(4+T)x4
AXIAL OUTDOOR UNIT Compressor type Outdoor airflow/Static pressure Sound pressure Refrigerant Refrigerant charge / Additional charge** Liquid pipe Liquid Liquid pipe Gas Max. piping length Pipe height difference Width/Height/Depth Net weight Power wiring (10 m max.) Shielded communication wires Power supply
!
2x1.5
2x1.5
2x1.5
220-240/1/50
380-400/3/50
380-400/3/50
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
133
ZEN R-410A COMMERCIAL
kW Kcal/h kW
INDOOR UNIT Indoor airflow Sound pressure (low speed) Width/Height/Depth Net weight Power wiring Shielded communication wires Power supply
DC
UNTIL END OF STOCK
SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./rated/max.) SEER Cooling energy class Heating capacity (min./nom./max.) Heating capacity (min./nom./max.) Heat input capacity (min./rated/max.) SCOP Heating efficiency class Heating capacity -7ºC COP -7ºC
x2
Mo
R-410A COMMERCIAL RANGE TWINS
DC INVERTER Motor ventilador Ext. consumo eléctrico
40W
TWINS
TECNOLOGIA
Menos ruido
The balance in the Zen range results in good service and greater comfort for users and installers. Zen Inverter units are fitted with a specific electronic board that allows for connecting two indoor units to the same outdoor unit. TWIN technology can be applied to compact Cassette 600x600, Art Flux 360º SuperSlim Cassette , ducts and Floor/Ceiling units. Furthermore, for the first time, sets of different indoor units can be made; i.e, you can combine, for example, a duct unit with a floor/ceiling type unit, among many other possibilities, provided that both indoor units are the same power.
Twins units represent the versatility and balance of the Zen range, and are presented as an option for commercial spaces that require more than one indoor unit to achieve a suitable air-conditioning without demanding more outdoor units.
In ZEN Twins sets, one can choose from two types of indoor unit. You can create your own Twin set by combining the 2 indoor units that suit you best, provided that they have the same capacity.
+
+
INDOOR UNIT 600x600 cassette SuperSlim cassette Duct FLOOR / CEILING
INDOOR UNIT 600x600 cassette SuperSlim cassette Duct FLOOR / CEILING
+
STANDARD KID-02 S KC-03.1 SPS
Maximum height difference between indoor units of a TWIN system: 0.5 metres Branch pipe not included. Add T-type branch pipe or Kaysun KCMI 112 branch pipe
L
L1
L2
OUTDOOR UNIT (AXIAL OR CENTRIGUAL)
UNIT A
Maximum distance (L+L1+L2)
PIPE DISTANCE
UNIT B
52+52 indoor combination (A+B)
50 m.
71+71 indoor combination (A+B)
65 m.
90+90 indoor combination (A+B)
65 m.
Maximum distance between the branch pipe and the indoor unit (L1 and L2)
15 m.
Maximum difference in length between the branch pipe and the indoor units (L1-L2)
10 m.
Between outdoor unit and indoor units
20 m.
Between indoor units (A and B)
0.5 m.
LEVEL DIFFERENCE
134
Menos vibración
Twins combinations can be arranged with th following power characteristics: - Outdoor unit of 10.5kW with two indoor units of 5.2kW - Outdoor unit of 14.0kW with two indoor units of 7.1kW - Outdoor unit of 16.0kW with two indoor units of 9.0kW
DIFFERENT TYPES OF INDOOR UNIT CAN BE COMBINED
OUTDOOR UNIT
Ro
TRIPLE DC INVERTER
Protección IPX4
Eficiente ≥70%
Inspiration, Innovation, Evolution
AXIAL COMBINED SYSTEMS
R-410A
INDOOR UNIT
x2
OUTDOOR UNIT
ZEN R-410A COMMERCIAL
SETS (600 x 600) RECOMMENDED CONTROL
KCI-52 DN10
KUE-105 DVN10
KID-02 S
KCI-52 DN10
KUE-105 DTN10
KID-02 S
OUTDOOR UNIT
RECOMMENDED CONTROL
SUPERSLIM CASSETTE INDOOR UNIT
x2
KCIS-52 DR11
KUE-105 DVN10
KID-02 S
KCIS-52 DR11
KUE-105 DTN10
KID-02 S KID-02 S
KCIS-71 DR11
KUE-140 DVN10
KCIS-71 DR11
KUE-140 DTN10
KID-02 S
KCIS-90 DN10
KUE-160 DTN10
KID-02 S
OUTDOOR UNIT
RECOMMENDED CONTROL
Ducts
NEW
INDOOR UNIT KPD-52 DR11
x2
KUE-105 DVN10
KC-03.1 SPS
KPD-52 DR11
KUE-105 DTN10
KC-03.1 SPS
KPD-71 DR11
KUE-140 DVN10
KC-03.1 SPS
KPD-71 DR11
KUE-140 DTN10
KC-03.1 SPS
KPD-90 DN11
KUE-160 DTN10
KC-03.1 SPS
OUTDOOR UNIT
RECOMMENDED CONTROL
FLOOR / CEILING INDOOR UNIT
x2
KPC-52 DR11
KUE-105 DVN10
KID-02 S
KPC-52 DR11
KUE-105 DTN10
KID-02 S
KPC-71 DR11
KUE-140 DVN10
KID-02 S
KPC-71 DR11
KUE-140 DTN10
KID-02 S
KPC-90 DN10
KUE-160 DTN10
KID-02 S
R-410A
CENTRIFUGAL COMBINED SYSTEMS SUPERSLIM CASSETTE INDOOR UNIT
x2
OUTDOOR UNIT
RECOMMENDED CONTROL
KCIS-71 DR11
KUEC-140 DTN10
KID-02S
KCIS-90 DN10
KUEC-160 DTN10
KID-02 S
Ducts
NEW
INDOOR UNIT
OUTDOOR UNIT
RECOMMENDED CONTROL
KPD-71 DR11
KUEC-140 DTN10
KC-03.1 SPS
KPD-90 DN11
KUEC-160 DTN10
KC-03.1 SPS
x2
FLOOR / CEILING INDOOR UNIT
OUTDOOR UNIT
RECOMMENDED CONTROL
KPC-71 DR11
KUEC-140 DTN10
KID-02 S
KPC-90 DN10
KUEC-160 DTN10
KID-02 S
x2
135
R-410A COMMERCIAL RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
SANGULÍ BUENAVISTA CONFERENCE CENTRE CAMPINGCENTRE RESORT BUSINESS Location:Oviedo Cambrils (Tarragona) Location: Initialsituation: situation:New Renovation Initial construction Units Unitsinstalled: installed:Zen ZenInverter Axial Capacity: Capacity: 140 1000kW kW
THE ZEN RANGE FOR COMMERCIAL APPLICATIONS OFFERS MULTIPLE INSTALLATION POSSIBILITIES THAT ARE HIGHLY ENERGYEFFICIENT AND ENVIRONMENTALLYFRIENDLY. ITEMS IN THE ZEN AXIAL RANGE EQUIPPED WITH AN OUTDOOR AXIAL UNIT ARE THE MOST COMPACT SOLUTION FOR ITS INSTALLATION.
OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN ZEN HOTELS, PUBLIC BUILDINGS HOSPITALS, HEALTH CLINICS AND CENTRES Autism Association of Jeréz (Cádiz), Joan XXIII Hospital (Tarragona), Salamanca Hospital (Salamanca), Sagrado Corazón Health Clinic (Madrid), Museum of Oil (Jaén), Depentya Foundation (Seville), Nuevo Arcangel Football Stadium (Córdoba)
136
PRIVATE RESIDENCES Residential Complex (Vera), Alpe Property Developments (Tortosa), 134 private residences in East Seville (Seville), Mercainmo Property Developments (Lleida), Residential Complex (Marbella), 503 private residences in Bekinsa Residential Complex (Seville), Las Brisas Hotel (Llanes)
BUSINESS CENTRES AND OFFICES Navarrete Offices (La Rioja), Eder Epele offices (Guipúzcoa), Greg Business Centre (Barcelona), Trade Fair (Valladolid), Electric Rooms- Asturiana del Zinz S.A.U. (Asturias), Galvanizados Avilés offices (Avilés), Retevisión Valladolid (Valladolid), Eiffage Energy offices (Ávila), Acofarma offices (Terrassa), Jordi Verna offices (Granollers),
Banca March offices (Mallorca), Carrefour offices (Málaga), Barceló Market (Madrid), Day SWRO Desalination offices (Marruecos), Caja Rural Zamora bank offices (Zamora) RESTAURANTS 100 Montaditos Brewery (Córdoba), Vermut Rofes Restaurants (Reus), La Sureña Brewery (Córdoba), WOK Restaurant (Cáceres)
COMMERCIAL BUILDING Unity Skates shop (Zaragoza), Lecrerc Mall (Málaga), Confecciones Rubio clothes shop (Cádiz, Seville and Córdoba), Aurgi (Madrid), Toyota authorised dealer (Oviedo), Stradivarius (Manresa), Vitaldent dental clinic (different locations), Lacoste (Vilagarcía de Arousa), Lowfit Gym (Seville), Basic Fit Gym (Madrid) , Alimerka Supermarkets (León)
Inspiration, Innovation, Evolution
VALLADOLID TRADE FAIR
HOSPITALS
CONFERENCE CENTRES
ZEN R-410A COMMERCIAL
HOSPITAL DE SALAMANCA
Location: Salamanca Units installed: Zen Axial Capacity: 100 kW
Location: Valladolid Units installed: Zen Axial Capacity: 110 kW
ROMAN THEATRE OF MERIDA HISTORIC BUILDING
CERVECERIA LA SUREÑA
Location: Mérida Units installed: Centrifugal Zen Capacity: 32 kW
Location: Córdoba Units installed: Centrifugal Zen Capacity: 50 kW
RESTAURANT
STRADIVARIUS
AMD DECOLLETAGE
FASHION STORES
AUTOMOTIVE COMPONENTS FACTORY
Location: Manresa Units installed: Centrifugal Zen Capacity: 30 kW
Location: Marnaz (France) Units installed: KPD 90 DVN10 Capacity: 10.55 kW
137
ZEN ZEN R-32 COMMERCIAL RANGE
INTRODUCTION TO THE PRODUCT RANGE....................................... ..140 SETS........................................................................................................ ..142 SUPERSLIM CASSETTE.................................................................... ..144 FLOOR / CEILING.............................................................................. ..146 DUCTS ............................................................................................... ..148
ZEN R-32 COMMERCIAL
ZEN
ZEN R-32 COMMERCIAL RANGE
ZEN R-32 COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
ZEN
“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT”
R-32 COMMERCIAL RANGE
Introducing our commercial range units using R-32 refrigerant. The main characteristics of this range we wish to highlight are its advanced technology, its efficiency, its versatility and its performance. Combinations made with axial outdoor units are fitted with Inverter technology, thereby optimising energy efficiency and seasonal performance indicators. The outdoor units of this type have an
R-32 REFRIGERANT UNITS
aesthetic with a robust design and good sound performance. It could be said that the controls of this range are at the expected height. The KID-02 S, a wireless smart control that can inspect the operation of units and change configuration parameters. Regarding wired controllers, we offer the KC-03.1 SPS controller, which is able to adjust the static pressure of the Ducts Unit. Furthermore, it should be pointed out that this year some models in this range will have optional Wi-Fi control.
NEW
Last year, Frigicoll, by means of its KAYSUN brand, started marketing some of its products fitted with R-32 refrigerant. The new EU regulations encourages the use of alternative gases, such as R-32 refrigerant gas. The R-32 has a 675 global warming potential (GWP), a very low rate if compared to the 2,088 GWP produced by R-410A refrigerant. It is more cost-efficient, 10 % more suitable and reduces charge volume by 25% because it is more compact. In addition, it offers better performance at an extreme outdoor temperature and is easy to reuse and recycle, as it is made up of a single refrigerant component.
+ + +
STRONGER AND COMPACT
PERFORMANCE
ENERGY SAVING
SOUND LEVEL
SMART CONTROLLERS Kaysun’s ZEN series has a top range of controllers. The cable and wireless controls have the most technologically-advanced functions and utilities, but with a modern and avant-garde aesthetic.
KC-03.1 SPS
140
KID-02 S
+
WEEKLY TIMER
+
INSTALLATION PARAMETRES MODIFICATION
+
DUCT UNIT’S STATIC PRESSURE ADJUSTMENT
+
OPERATION PARAMETERS CHECKING
+
FOLLOW ME
+
FOLLOW ME
Inspiration, Innovation, Evolution
DUCT UNIT
NEW
• Removable filter (it can be extracted without touching the unit). • Flange for fitting the outlet duct. • Flange for fitting the intlet (return) duct. • Double return system possibility rear or lower inlet. • Condensation pump. • Pre-installation for fresh air inlet.
• Electric box removable up to 1 metre apart from the unit's body. • Voltage-free Alarm and ON/OFF dry contacts. • The KC-03.1 SPS controller allows adjusting the available pressure automatically. • Up to 160 Pa available depending on the model. • Horizontal and vertical installation. • Reduced height unit.
Compatible with
TWO COMMUNICATION WIRES
x2
The ZEN R-32 range units only require two shielded wires without polarity to carry out the operation. This new characteristic makes the communication wiring works cheaper and easier.
K03 WIFI LCAC
NEW
has an optional WiFi adapter for some of its indoor unit models in the ZEN range. This accessory connects the unit to our domestic WiFi network and controls it through an App installed on our Smartphone. The application also includes a weekly timer built into the App to ease and improve the control function of our air-conditioning system.
S1 S2
S1 S2
141
ZEN R-32 COMMERCIAL
With regard to the semi-industrial indoor units of the ZEN RANGE, we would like to highlight the Duct unit. We believe that this is one of the most comprehensive units in the market due to the great amount of options and functions included, such as:
ZEN R-32 COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
CASSETTE R-32
142
Inspiration, Innovation, Evolution
POWER kW
3.5
5.2
7.1
9.0
10.5
12.5
14.0
16.0
SETS R-32 NEW
SUPERSLIM CASSETTE
KCIS-105 DVR11 KCIS-105 DTR11
KCIS-140 DTR11
KCIS-160 DTR11
KPC-71 DVR11
KPC-105 DVR11 KPC-105 DTR11
KPC-140 DTR11
KPC-160 DTR11
KPD-71 DVR11
KPD-105 DVR11 KPD-105 DTR11
KPD-140 DTR11
KPD-160 DTR11
KCIS-71 DVR11
ZEN R-32 COMMERCIAL
KCIS-52 DVR11
(Page 144)
R-32 NEW
FLOOR / CEILING KPC-52 DVR11
(Page 146)
NEW
Ducts
(Page 148) KPD-52 DVR11
143
ZEN R-32 COMMERCIAL RANGE SUPERSLIM CASSETTE TYPE SETS
SUPERSLIM CASSETTE
R-32 NEW
GENERAL CHARACTERISTICS In order to provide users with maximum comfort, the cassette units are fitted with a 360° air diffusion system that allows them to reach every corner of the room. They have an impeccable appearance, a compact structure and a slim design to adapt to spaces with low ceilings. •
Pre-installed inlet for fresh air.
•
Voltage-free alarm and ON/OFF dry contacts.
•
Standard condensation pump.
•
360º airflow.
•
Louvres position storage.
•
Prepared for side ducts (closing air outlets).
•
Slim design compact unit.
+
STANDARD CONDENSATION PUMP
KID-02 S (*) RECOMMENDED
NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the € price for the set, the price difference between the recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range
INDIVIDUAL
CENTRALISED
KID-02 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
K01-KNX
K01-WIFI
BMS AND SOFTWARE
K01-LON
144
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
Inspiration, Innovation, Evolution
4.0
DC
x2
SCOP
R-32
50/60
!
Hz
DC
TECHNICAL CHARACTERISTICS SET kW
1.26/5.28/6.15
2.23/7.03/8.21
2.64/10.55/12.02
2.64/10.55/12.02
4.76/14.0/14.58
5.28/15.8/16.71
Kcal/h
1085/4540/5289
1917/6045/7061
2270/9073/10335
2270/9073/10337
3430/12040/12540
4540/13585/14340
kW
0.28/1.64/2.15
0.48/2.19/2.85
0.66/3.75/4.5
0.66/3.95/4.5
1.17/5.13/5.6
1.14/5.95/6.68
6.1
6.1
6.1
6.1
6.1
6.1
A++
A++
A++
A++
A++
A++
kW
1.76/5.57/7.03
2.43/7.62/8.65
2.93/11.14/13.19
2.93/11.14/13.19
3.93/16.1/16.77
4.4/18.2/19.34
Kcal/h
1515/4790/6046
2090/6550/7439
2520/9580/11343
2519/9580/11343
3600/13840/14420
3785/15650/16630
kW
0.33/1.5/2.18
0.5/2.05/2.88
0.65/2.96/4.55
0.65/2.96/4.55
0.98/5.05/5.38
1.02/6.03/6.45
SCOP
4.0
4.0
4.0
4.0
4.0
4.0
Heating efficiency class
A+
A+
A+
A+
A+
A+
SEER Cooling energy class Heating capacity (min./rated/max.) Heating capacity (min./rated/max.) Heat input capacity (min./rated/max.)
INDOOR UNIT
KCIS-52 DR11
KCIS-71 DR11
KCIS-105 DR11
Indoor airflow
m3/h
1036/867/763
1378/1200/1032
1775/1620/1438
KCIS-105 DR11 KCIS-140 DR11 KCIS-160 DR11 1775/1620/1438
1715/1568/1381
1970/1737/1537
Sound pressure (Low speed)
dB (A)
37
40
46
46
49
48
Width/Height/Depth
mm
840/205/840
840/205/840
840/245/840
840/245/840
840/287/840
840/287/840
Net weight
Kg
21.3
23
27.5
27.5
29
29.7
Width/Height/Depth (panel)
mm
950/55/950
950/55/950
950/55/950
950/55/950
950/55/950
950/55/950
Kg
5
5
5
5
5
5
Power wiring
Net weight (panel)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
OUTDOOR UNIT
KUE-52 DVR11
Compressor type
KUE-71 DVR11 KUE-105 DVR11 KUE-105 DTR11 KUE-140 DTR11 KUE-160 DTR11
Rotary
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
Outdoor airflow
m3/h
2100
2700
4000
4000
7500
7500
Sound pressure
dB (A)
57
62
65
65
66
66
R-32
R-32
R-32
R-32
R-32
R-32
gr
1350 / 12
1500 / 24
2400 / 24
2400 / 24
2800 / 24
2950 / 24
Liquid pipe Liquid
mm (inch")
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Liquid pipe Gas
mm (inch")
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
Max. piping length
m
30
50
65
65
65
65
Pipe height difference
m
20
25
30
30
30
30
Width/Height/Depth
mm
800/554/333
845/702/363
946/810/410
946/810/410
952/1333/415
952/1333/415
Refrigerant Refrigerant charge / Additional charge**
Kg
35.5
66.8
66.8
81.5
106.7
111.3
Power wiring (10 m max.)
Net weight
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x4
(4+T)x2.5
(4+T)x4
(4+T)x6
Shielded communication wires
mm2
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
380-400/3/50
380-400/3/50
380-400/3/50
Power supply
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
145
ZEN R-32 COMMERCIAL
Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cold input capacity (min./ rated/max.)
KCIS-52 DVR11 KCIS-71 DVR11 KCIS-105 DVR11 KCIS-105 DTR11 KCIS-140 DTR11 KCIS-160 DTR11
ZEN R-32 COMMERCIAL RANGE FLOOR / CEILING SETS
FLOOR / CEILING
R-32 NEW
GENERAL CHARACTERISTICS
Kaysun Zen range makes air conditioning at your disposal through its most versatile product, the Floor/Ceiling units. Compact and state-of-the-art design that integrates into every room environment. A simple and, at the same time, versatile unit. •
Easy access to components for maintenance.
•
Improved airflow for a greater comfort.
•
FLOOR or CEILING installation.
•
Voltage-free alarm and ON/OFF dry contacts.
•
New numerical display in the receiver.
•
On/Off and Alarm dry contacts.
+
CEILING/FLOOR COMPATIBLE
+
VOLTAGE FREE CONTACTS + ALARM
KID-02 S (*) RECOMMENDED
NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the € price for the set, the price difference between the recommended controller and the selected controller.
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
KID-02 S
CENTRALISED
KC-03.1 SPS
KC-03 SPS
KC-02.1 H
KC-01 S
KCT-02.1 SR
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
146
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
4.0 SCOP
R-32
x2
50/60 Hz
!
TECHNICAL CHARACTERISTICS
Cooling capacity (min./ rated/max.) Cooling capacity (min./ rated/max.) Cold input capacity (min./rated/max.)
KPC-52 DVR11 kW
1.29/5.28/6.15
2.20/7.03/8.21
2.64/10.55/12.02
2.64/10.55/12.02
Kcal/h
1110/4540/5290
1891/6046/7061
2270/9073/10337
2270/9073/10337
kW
0.28/1.64/2.15
0.48/2.19/2.85
0.66/3.75/4.5
0.66/3.95/4.5
1.16/5.5/5.7
1.23/6.06/6.29
6.1
6.1
6.1
6.1
6.1
6.1
A++
A++
A++
A++
A++
A++
kW
1.76/5.57/7.03
2.43/7.62/8.65
2.93/11.14/13.19
2.93/11.14/13.19
3.81/16.1/18.07
4.4/18.2/19.64
Kcal/h
1513/4790/6046
2090/6550/7439
2520/9575/11343
2520/9575/11343
kW
0.33/1.5/2.18
0.5/2.05/2.88
0.65/2.96/4.5
0.65/3.0/4.55
1.02/5.05/6.2
1.02/6.03/6.54
SCOP
4.0
4.0
4.0
4.0
4.0
4.0
Heating efficiency class
A+
A+
A+
A+
A+
A+
SEER Cooling energy class Heating capacity (min./ rated/max.) Heating capacity (min./ rated/max.) Heat input capacity (min./rated/max.)
INDOOR UNIT Indoor airflow Sound pressure (Low speed) Width/height/depth (ceiling installation) Net weight
KPC-71 DVR11 KPC-105 DVR11 KPC-105 DTR11 KPC-140 DTR11 KPC-160 DTR11 4.96/14.2/15.11
5.28/16.0/17.0
4265/12210/12990 4540/13760/14620
3275/13845/15540 3785/15650/16890
KPC-52 DR11
KPC-71 DR11
KPC-105 DR11
KPC-105 DR11
KPC-140 DR11
KPC-160 DR11
m3/h
900/780/675
1200/1060/850
2160/1845/1430
2160/1844/1430
2330/1930/1415
2450/1830/1430
dB (A)
37
41
42
42
46
42
mm
1068/235/675
1068/235/675
1650/235/675
1650/235/675
1650/235/675
1650/235/675
Kg
26.6
26.8
39
39
46
41.4
Power wiring
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
OUTDOOR UNIT
KUE-52 DVR11
Compressor type
KUE-71 DVR11 KUE-105 DVR11 KUE-105 DTR11 KUE-140 DTR11 KUE-160 DTR11
Rotary
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
Outdoor airflow
m3/h
2100
2700
4000
4000
7500
7500
Sound pressure
dB (A)
57
62
65
65
66
66
R-32
R-32
R-32
R-32
R-32
R-32
gr
1350 / 12
1500 / 24
2400 / 24
2400 / 24
2800 / 24
2950 / 24
Inlet liquid pipe Liquid
mm (inch")
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Inlet liquid pipe Gas
mm (inch")
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
Max. piping length
m
30
50
65
65
65
65
Pipe height difference
m
20
25
30
30
30
30
Width/Height/Depth
mm
800/554/333
845/702/363
946/810/410
946/810/410
952/1333/415
952/1333/415
Net weight
Kg
35.5
66.8
66.8
81.5
106.7
111.3
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x4
(4+T)x2.5
(4+T)x4
(4+T)x6
mm2
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
380-400/3/50
380-400/3/50
380-400/3/50
Refrigerant Refrigerant charge / Additional charge**
Power wiring (10 m max.) Shielded communication wires Power supply
2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
147
ZEN R-32 COMMERCIAL
SET
ZEN R-32 COMMERCIAL RANGE DUCTS SETS
Ducts
NEW
GENERAL CHARACTERISTICS
Kaysun ducts units offer a wide range of features, which turns them into one of the best products in the market. These units can be easily installed in small spaces, such as compact suspended ceilings, thanks to the tilted position of their battery, which provides them with a slim design. • Easily removable filter.
• Electric box removable up to 1 metre apart from the unit's body.
• Flanges in the inlet and outlet mouths.
• Up to 160 Pa available depending on the model.
• Possibility for double air intake (rear or lower intake). • Fresh air intake at a side of the unit.
• The KC-03.1 SPS controller allows adjusting the available pressure automatically.
• Voltage-free alarm and ON/OFF dry contacts.
• Horizontal and vertical installation.
• Standard condensation pump of up to 750 mm in height.
• Reduced height unit.
+
VERTICAL INSTALLATION (OPTIONAL)
+
STANDARD CONDENSATION PUMP up to 750 mm HEIGHT
Compatible with
NEW OPTIONAL WIFI K03 WIFI LCAC ACCESSORY
KC-03.1 SPS PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you shall add to the € price for the set, the price difference between the recommended controller and the selected controller.
(*) RECOMMENDED
SINGLE
For further information, please see our Controllers Range
INDIVIDUAL
KID-02 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KC-03.1 SPS
KC-03 SPS
KC-02.1 H
KC-01 S
KCT-02.1 SR
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
148
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
Inspiration, Innovation, Evolution
4.0 R-32
x2
SCOP
50/60 Hz
!
TECHNICAL CHARACTERISTICS
Cooling capacity (min./ rated/max.) Cooling capacity (min./ rated/max.) Cold input capacity (min./rated/max.)
KPD-52 DVR11
KPD-71 DVR11 KPD-105 DVR11 KPD-105 DTR11 KPD-140 DTR11 KPD-160 DTR11
kW
1.23/5.28/6.15
2.2/7.03/8.21
2.93/10.55/12.02
2.93/10.55/12.02
4.1/14.07/16.41
4.98/15.82/18.11
Kcal/h
679/4541/5289
1032/6046/7061
2520/9073/10337
2520/9073/10337
3526/12100/14113
4283/13605/15575
KW
0.28/1.64/2.15
0.48/2.19/2.85
0.98/3.97/4.62
0.98/3.97/4.62
1.37/5.12/6.31
1.66/5.26/6.97
6.1
6.1
6.3
6.1
6.1
6.1
A++
A++
A++
A++
A++
A++
KW
1.76/5.57/7.03
2.43/7.62/8.65
2.64/11.13/13.19
2.64/11.13/13.19
4.34/16.12/18.13
5.28/18.17/20.51
Kcal/h
757/4876/6046
1032/6046/7439
2270/9575/11343
2270/9575/11343
3732/13863/15592
4541/15626/17639
KW
0.5/2.05/2.88
0.5/2.05/2.88
0.88/2.92/4.69
0.88/2.92/4.69
1.45/4.36/6.48
1.76/5.03/7.32
SCOP
4.0
4.0
4.0
4.0
4.0
4.0
Heating efficiency class
A+
A+
A+
A+
A+
A+
SEER Heating energy class Heating capacity (min./ rated/max.) Heating capacity (min./ rated/max.) Heat input capacity (min./rated/max.)
INDOOR UNIT
KPD-52 DR11
KPD-71 DR11
KPD-105 DR11
KPD-105 DR11
KPD-140 DR11
KPD-160 DR11
3
m /h
1000/853/684
1550/1350/1150
2000/1650/1250
2000/1650/1250
2900/2600/2100
2900/2600/2100
Pa
100
160
160
160
160
160
dB (A)
40
40
40
40
48
50.5
Width/Height/Depth
mm
1055/210/674
1100/249/774
1360/249/774
1360/249/774
1200/300/874
1200/300/874
Net weight
Kg
25.6
31.5
40.5
40.5
47.6
47.6
Air flow Maximum pressure available Sound pressure (low speed)
Power wiring
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires***
mm
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
2 2
OUTDOOR UNIT
KUE-52 DVR11
Compressor type Outdoor airflow
m3/h
Sound pressure
dB (A)
Refrigerant
KUE-71 DVR11 KUE-105 DVR11 KUE-105 DTR11 KUE-140 DTR11 KUE-160 DTR11
Rotary
Double rotary
Double rotary
Double rotary
Double rotary
Double rotary
2100
2700
4000
4000
7500
7500
57
62
65
65
66
66
R-32
R-32
R-32
R-32
R-32
R-32
Refrigerant charge / Additional charge** Diameter of cooling line Liquid
gr
1350 / 12
1500 / 24
2400 / 24
2400 / 24
2800 / 24
2950 / 24
mm (Inch)
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Inlet liquid pipe Gas
mm (Inch)
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
Max. piping length
m
30
50
65
65
65
65
Pipe height difference
m
20
25
30
30
30
30
Width/Height/Depth
mm
800/554/333
845/702/363
946/810/410
946/810/410
952/1333/415
952/1333/415
Net weight
Kg
35.5
66.8
66.8
81.5
106.7
111.3
mm
(2+T)x2.5
(2+T)x2.5
(2+T)x4
(4+T)x2.5
(4+T)x4
(4+T)x6
mm2
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
2x1.5
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
380-400/3/50
380-400/3/50
380-400/3/50
Power wiring (10 m max.) Shielded communication wires Power supply
2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. **Factory pre-charge for 5 metres of installation / Additional charge per metre added after 5 metres. Working temperature range: -15ºC to 50ºC (Cooling) / -15ºC to 24ºC (Heating)
149
ZEN R-32 COMMERCIAL
SET
ZEN HIGH CAPACITY COMMERCIAL RANGE
INTRODUCTION TO THE PRODUCT RANGE....................................... ..152 HIGH-CAPACITY DUCT SETS................................................................ ..153 AIR CONDENSED - FRONT DISCHARGE.......................................... ..154 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN3................. ..156 AIR CONDENSED UNITS - VERTICAL DISCHARGE DN4 S.............. ..158 WATER CONDENSED....................................................................... ..160 STATIC PRESSURE GRAPHS............................................................ ..162
KEY INSTALLATIONS........................................................................... ..164
HIGH CAPACITY COMMERCIAL RANGE
ZEN ZEN ZEN HIGH CAPACITY CAPACITY HIGH COMMERCIAL COMMERCIAL
HIGH CAPACITY COMMERCIAL RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
ZEN
HIGH CAPACITY COMMERCIAL RANGE
We present the high-capacity commercial range. The main characteristics we wish to highlight in this range are its vast cooling power and large air flows. These machines are ideal for climate control in large spaces. Most of these combinations are equipment with a compressor, outdoor ventilators and indoor ventilators with DC Inverter technology, resulting in efficiency and energy savings.
“HIGH-PERFORMANCE COMMERCIAL EQUIPMENT” Basically, we have 6 power levels of indoor units that rangefrom 20 to 56 kW, and which can be combined with different types of the outdoor unit: front discharge, vertical discharge and water condensation.
OUTDOOR UNITS The high-capacity commercial range contains four different types of outdoor unit, ensuring perfect adaptability to each different type of installation:
FRONT AIR DISCHARGE
VERTICAL AIR DISCHARGE
R-410A LITTLE INSTALLATION SPACE
TWIN ROTARY COMPRESSORS
R-410A WHILE STOCKS LAST STATIC PRESSURE AVAILABLE 40 PA UP TO 200 METRES IN LENGTH FOR PIPELINES
CONDENSED BY WATER NEW
R-410A
152
R-410A
FULL DC INVERTER
EXTREMELY COMPACT
STATIC PRESSURE AVAILABLE 60 PA
INDOOR INSTALLATION
UP TO 200 METRES IN LENGTH FOR PIPELINES
Inspiration, Innovation, Evolution
HIGH AIRFLOWS Duct units in the high-capacity commercial rangeare made up of indoor units of ducts with large airflows at high static pressure levels.
STATIC PRESSURE OF UP TO 200 PA
CASSETTE POWER kW
20.0
25.0
28.0
40.0
45.0
56.0
AIR CONDENSED FRONT AIR DISCHARGE (Page 154) KPDHF-200F DN2
KPDHF-250F DN2
KPDHF-280F DN2
VERTICAL DISCHARGE DN3 (Page 156)
KPDHF-400F DN3
WHILE STOCKS LAST
KPDHF-280V DN3
VERTICAL DISCHARGE DN4 S (Page 158)
KPDHF-400V DN3
KPDHF-450V DN3
KPDHF-560 DN3
KPDHF-400V DN4 S
KPDHF-450V DN4 S
KPDHF-560V DN4 S
NEW
KPDHF-280V DN4 S
WATER CONDENSED
KPDHF-450F DN3
(Page 160)
KPDHF-250W DN3
KPDHF-280W DN3
KPDHF-560W DN3
153
ZEN HIGH CAPACITY COMMERCIAL
HIGH AIRFLOWS
HIGH CAPACITY COMMERCIAL RANGE AIR CONDENSED
HIGH CAPACITY DUCTS AIR CONDENSED - FRONT DISCHARGE TECHNICAL SPECIFICATIONS SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input
KPDHF-200F DN2
KPDHF-250F DN2
KPDHF-280F DN2
KPDHF-400F DN3
KPDHF-450F DN3
kW
10.0/20.0/21.1
13.0/25.0/27.5
13.0/26.1/27.5
20.0/40.0/42.3
22.5/45.0/47.6
Kcal/h
8600/17200/18146
11180/21500/23650
11180/22446/23650
17200/34400/ 36378
19350/38700/40936
W
7610
9015
9110
14300
16300
kW
11.0/22.0/26.1
14.3/27.0/33.7
14.3/28.5/33.7
22.5/45.0/53.3
25.0/50.0/59.2
19350/38700/ 45838
21500/43000/50912
13800
15400
Kcal/h 9460/18920/22446 12298/23220/28982 12298/24510/28982 W
INDOOR UNIT
7610
8255
8310
KPDHF-200 DN3.0
KPDHF-250 DN3.0
KPDHF-280 DN3.0
KPDHF-400 DN2.4
KPDHF-450 DN2.4
m3/h
4800/3900/3500
4600/4000/3600
4600/4000/3600
7700/6400/5200
7700/6400/5200
Maximum pressure available
Pa
200
200
200
200
200
Sound pressure (low speed)
dB (A)
50
50
50
56
56
mm
1443/470/810
1443/470/810
1443/470/810
1970/668/903
1970/668/903
Air flow
Width/Height/Depth Net weight Power wiring Communication wiring . Power supply
Kg
108
108
108
232
232
mm2
(2+T)x4
(2+T)x4
(2+T)x4
(2+T)x4
(2+T)x4
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
KMF-200 DN2
KMF-260 DN2
KMF-260 DN2
KMF-400 DN3
KMF-450 DN3
OUTDOOR UNIT Compressor type
Double rotary
Double rotary
Double rotary
Double rotary (2)
Double rotary (2)
m3/h
10999
10494
10494
16575
16575
Static Pressure
Pa
No
No
No
No
No
Sound pressure
dB (A)
59
60
60
62
62
R-410A
R-410A
R-410A
R-410A
R-410A
Outdoor airflow
Refrigerant Refrigerant volume
gr
4800
6200
6200
9000
12000
Inlet liquid pipe Liquid*
mm (inch)
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø12.7 (1/2”)
ø12.7 (1/2”)
Inlet liquid pipe Gas*
mm (inch)
ø19.1 (3/4")
ø22.2 (7/8")
ø22.2 (7/8")
ø25.4 (1")
ø25.4 (1")
m
60
60
60
120
120
Max. piping length Pipe height difference
m
30
30
30
30
30
Width/Height/Depth
mm
1120/1558/528
1120/1558/528
1120/1558/528
1360/1650/540
1460/1650/540
Net weight Power wiring (Max. 10 m) Communication wiring . Power supply
Kg
137
147
147
240
275
mm2
(4+T)x4
(4+T)x4
(4+T)x4
(4+T)x16
(4+T)x16
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
380-415/3/50
380-415/3/50
380-415/3/50
380-415/3/50
380-415/3/50
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 45 metres, please check diameter with our Technical Department. KMF-200/260 working rate: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating) KMF-400/450 working rate: -15ºC to 48ºC (Cooling) / -15ºC to 24ºC (Heating)
154
Inspiration, Innovation, Evolution
R-410A
DC
DC
INVERTER
GENERAL CHARACTERISTICS
Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •
Indoor unit internal expansion system.
•
220 V ALARM OUTPUT.
•
Available pressure up to 200 Pa.
•
•
Voltage-free ON/OFF dry contact.
Smaller units, 200, 250 and 280 have inverter indoor fan motor.
TEMPERATURE ADJUSTMENT / GREATER COMFORT
+
VOLTAGE-FREE CONTACTS
ZEN HIGH CAPACITY COMMERCIAL
+
KCT-02.1 SR (*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
KI-02.3 S
CENTRALISED
KCT-02.1 SR
KC-01 S
KC-02.1 H
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
K01-KNX
K01-WIFI
KAYNET CONTROL
155
HIGH CAPACITY COMMERCIAL RANGE AIR CONDENSED
HIGH CAPACITY DUCTS
AIR CONDENSED - VERTICAL DISCHARGE DN3
TECHNICAL SPECIFICATIONS
UNTIL END OF STOCK
KPDHF-280V DN3
SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input
KPDHF-400V DN3 KPDHF-450V DN3 KPDHF-560V DN3
kW
14.0/28.0/29.6
20.0/40.0/42.3
22.5/45.0/47.6
28.0/56.0/59.2
Kcal/h
12040/24080/25456
17200/34400/36378
19350/38700/40936
24080/48160/50912
W
8000
15000
16710
20400
kW
15.8/31.5/37.3
22.5/45.0/53.3
25.0/50.0/59.2
31.5/63.0/74.6
Kcal/h
13588/27090/32078
19350/38700/45838
21500/43000/50912
27090/54180/64156
W
8400
13890
15480
19400
KPDHF-280 DN3.0
KPDHF-400 DN2.4
KPDHF-450 DN2.4
KPDHF-560 DN2.4
m3/h
4600/4000/3600
7700/6400/5200
7700/6400/5200
10100/8400/7000
Maximum pressure available
Pa
200
200
200
200
Sound pressure (low speed)
dB (A)
50
56
56
57
mm
1443/470/810
1970/668/903
1970/668/903
1970/668/903
INDOOR UNIT Air flow
Width/Height/Depth Net weight
Kg
108
232
232
235
Power wiring
mm2
(2+T)x4
(2+T)x4
(2+T)x4
(2+T)x4
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
K2UF-280 DN3
K2UF-400 DN3
K2UF-450 DN3
K2UF-560 DN3
Scroll Inv.
Scroll Inverter + Fixed Scroll (2)
Scroll Inverter + Fixed Scroll (2)
Scroll Inverter + Fixed Scroll (2)
m3/h
11000
15000
15000
18000
Static Pressure
Pa
40
40
40
40
Sound pressure
dB (A)
57
60
60
62
OUTDOOR UNIT Compressor type Outdoor airflow
Refrigerant
R-410A
R-410A
R-410A
R-410A
gr
10000
15000
15000
17000
Inlet liquid pipe Liquid*
mm (inch)
ø12.7 (1/2”)
ø12.7 (1/2”)
ø12.7 (1/2”)
ø15.9 (5/8")
Gas pipeline diameter*
mm (inch)
ø25.4 (1")
ø28.6 (1 1/8")
ø28.6 (1 1/8")
ø28.6 (1 1/8")
Max. piping length
m
150
175
175
200
Pipe height difference
m
70
70
70
110
Width/Height/Depth
mm
960/1615/765
1250/1615/765
1250/1615/765
1390/1615/765
Net weight
Kg
245
325
325
360
(4+T)x6
(4+T)x10
(4+T)x10
(4+T)x16
Refrigerant volume
Power wiring (10 m max.)
mm
Flared communication wires
mm
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
380-415/3/50
380-415/3/50
380-415/3/50
380-415/3/50
Power supply
2 2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 90 metres, please check diameter with our Technical Department. K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)
156
Inspiration, Innovation, Evolution
R-410A
DC
DC
INVERTER
GENERAL CHARACTERISTICS
Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •
Indoor unit internal expansion system.
•
Voltage-free ON/OFF dry contact.
•
Available pressure up to 200 Pa.
•
220 V ALARM OUTPUT.
•
Indoor unit 280 with Inverter fan.
TEMPERATURE ADJUSTMENT / GREATER COMFORT
+
VOLTAGE-FREE CONTACTS
ZEN HIGH CAPACITY COMMERCIAL
+
KCT-02.1 SR (*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
KI-02.3 S
CENTRALISED
KCT-02.1 SR
KC-01 S
KC-02.1 H
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
K01-KNX
K01-WIFI
KAYNET CONTROL
157
HIGH CAPACITY COMMERCIAL RANGE AIR CONDENSED NEW
HIGH CAPACITY DUCTS AIR CONDENSED - VERTICAL DISCHARGE DN4 S TECHNICAL SPECIFICATIONS KPDHF-280V DN4 S
KPDHF-400V DN4 S
KPDHF-450V DN4 S
KPDHF-560V DN4 S
kW
14.1/28.0/30.2
20.2/40.0/43.1
22.7/45.0/48.5
28.3/56.0/60.4
Kcal/h
12125/24075/25970
17370/34400/37060
19520/38695/41705
24335/48150/51935
W
7470
13700
15600
19400
kW
14.04/28.0/36.34
20.06/40.0/51.92
22.57/45.0/58.41
28.02/56.0/72.69
Kcal/h
12070/24075/31250
17250/38700/44650
19410/38700/50225
24100/48150/62500
W
6290
12000
13400
17200
SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input
KPDHF-280 DN3
INDOOR UNIT Air flow
KPDHF-400 DN2.4 KPDHF-450 DN2.4 KPDHF-560 DN2.4
3
m /h
4600/4000/3600
7700/6400/5200
7700/6400/5200
10100/8400/7000
Maximum pressure available
Pa
200
200
200
200
Sound pressure (low speed)
dB (A)
50
56
56
57
Width/Height/Depth
mm
443/470/810
1970/668/903
1970/668/903
1970/668/903
Net weight
Kg
108
232
232
235
(2+T)x4
(2+T)x4
(2+T)x4
Power wiring
mm
(2+T)x4
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
OUTDOOR UNIT
K2UF-280 DN4 S
K2UF-400 DN4 S
K2UF-450 DN4 S
K2UF-560 DN4 S
Compressor type
DC Inverter
DC Inverter
DC Inverter
DC Inverter
m3/h
11000
13000
13000
17000
Static Pressure
Pa
60
60
60
60
Sound pressure
dB (A)
58
62
65
66
Power supply
Outdoor airflow
2
Refrigerant
R-410A
R-410A
R-410A
R-410A
gr
11000
13000
13000
17000
Inlet liquid pipe Liquid*
mm (inch)
ø12.7 (1/2")
ø12.7 (1/2")
ø12.7 (1/2")
ø12.7 (1/2")
Gas pipeline diameter*
mm (inch)
ø25.4 (1")
ø28.6 (1 1/8”)
ø28.6 (1 1/8")
ø28.6 (1 1/8")
Max. piping length
m
175
175
175
175
Pipe height difference
m
90
90
90
70
Width/Height/Depth
mm
1090/1805/860
1340/1635/850
1340/1635/850
1340/1635/825
Net weight
Kg
227
277
277
344
(4+T)x6
(4+T)x10
(4+T)x10
(4+T)x16
Refrigerant volume
Power wiring (10 m max.)
mm
Flared communication wires
mm
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
380-415/3/50
380-415/3/50
380-415/3/50
380-415/3/50
Power supply
2 2
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 90 metres, please check diameter with our Technical Department. K2UF working range: -15ºC to 48ºC (Cooling) / -20ºC to 27ºC (Heating)
158
Inspiration, Innovation, Evolution
R-410A
DC
DC
INVERTER
GENERAL CHARACTERISTICS
Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •
Indoor unit internal expansion system.
•
Voltage-free ON/OFF dry contact.
•
Available pressure up to 200 Pa.
•
220 V ALARM OUTPUT.
•
Indoor unit 280 with Inverter fan.
TEMPERATURE ADJUSTMENT / GREATER COMFORT
+
VOLTAGE-FREE CONTACTS
ZEN HIGH CAPACITY COMMERCIAL
+
KCT-02.1 SR (*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
KI-02.3 S
CENTRALISED
KCT-02.1 SR
KC-01 S
KC-02.1 H
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
K01-KNX
K01-WIFI
KAYNET CONTROL
159
HIGH CAPACITY COMMERCIAL RANGE WATER CONDENSED
LARGE CAPACITY DUCTS WATER CONDENSED TECHNICAL SPECIFICATIONS KPDHF-250W DN3
KPDHF-280W DN3
KPDHF-560W DN3
kW
12.6/25.2/26.6
14.1/28.0/29.6
14.1/56.0/59.2
Kcal/h
10836/21672/22876
12126/24080/25456
12126/48160/50912
W
6310
7610
15600
kW
14.5/27.0/28.2
17.0/31.5/32.9
17.0/63.0/65.8
Kcal/h
12470/23220/24252
14620/27090/28294
14620/54180/56588
W
5960
7340
15060
SET Cooling capacity (min./rated/max.) Cooling capacity (min./rated/max.) Cooling input Heating Capacity (min./rated/max.) Heating capacity (min./rated/max.) Heating input
KPDHF-250 DN3.0
KPDHF-280 DN3.0
KPDHF-560 DN2.4
3
m /h
4600/4000/3600
4600/4000/3600
10100/8400/7000
Maximum pressure available
Pa
200
200
200
Sound pressure (low speed)
dB (A)
50
50
57
Width/Height/Depth
mm
1443/470/810
1443/470/810
1970/668/903
Net weight
Kg
108
108
235
INDOOR UNIT Air flow
Power wiring
mm
(2+T)x4
(2+T)x4
(2+T)x4
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
2
OUTDOOR UNIT Outdoor modules No Models Compressor type Sound pressure
dB (A)
Refrigerant
K2F-252 DN3W
K2F-280 DN3W
K2F-560 DN3W
1
1
2**
K2F-252 DN3W
K2F-280 DN3W
K2F-280 DN3W K2F-280 DN3W
Scroll Inverter
Scroll Inverter
Scroll Inverter
Scroll Inverter
51
52
52
52
R-410A
R-410A
R-410A
R-410A
gr
2000
2000
2000
2000
Inlet liquid pipe Liquid*
mm (inch")
ø9.52 (3/8")
ø9.52 (3/8")
ø15.9 (5/8")
Inlet liquid pipe Gas*
mm (inch")
ø22.2 (7/8")
ø22.2 (7/8")
ø28.6 (1 1/8")
Max. piping length
m
150
150
150
Pipe height difference
m
50
50
50
Width/Height/Depth
mm
780/1000/550
780/1000/550
780/1000/550
780/1000/550
Net weight
Kg
146
146
146
146
(4+T)x4
(4+T)x6
(4+T)x6
(4+T)x6
3x0.75
3x0.75
3x0.75
3x0.75
380-415/3/50
380-415/3/50
380-415/3/50
380-415/3/50
Refrigerant volume
Power wiring (10 m max.)
mm
2
Shielded communication wires
mm
2
Power supply
V / F / Hz
Note: Before installing these units, please check the standards in force in your country regarding the use of refrigerant gases. *For pipes longer than 90 metres, please check diameter with our Technical Department. **KCME branch pipe (200€) is required for joining outdoor modules
160
Inspiration, Innovation, Evolution
R-410A
DC
GENERAL CHARACTERISTICS
Kaysun high-pressure ducts have a higher static pressure to cover long distances, which provides greater installation flexibility and accurate air conditioning, even in rooms with high ceilings. •
Indoor unit internal expansion system.
•
220 V ALARM OUTPUT.
•
Available pressure up to 200 Pa.
•
•
Voltage-free ON/OFF dry contact.
Smaller units, 200, 250 and 280 have Inverter indoor unit fan motor.
CONDENSED BY WATER
+ +
ZEN HIGH CAPACITY COMMERCIAL
TEMPERATURE ADJUSTMENT / GREATER COMFORT
VOLTAGE-FREE CONTACTS
KCT-02.1 SR (*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the standard or recommended controller and the selected controller.
SINGLE
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range INDIVIDUAL
KI-02.3 S
CENTRALISED
KCT-02.1 SR
KC-01 S
KC-02.1 H
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
K01-KNX
K01-WIFI
KAYNET CONTROL
161
HIGH CAPACITY COMMERCIAL RANGE STATIC PRESSURE GRAPHS
HIGH CAPACITY DUCTS
STATIC PRESSURE GRAPHS
KPDHF-200 DN3.0
KPDHF-250 (280) DN3.0
162
Inspiration, Innovation, Evolution
ZEN HIGH CAPACITY COMMERCIAL
KPDHF-400(450) DN 2.4
KPDHF-560 DN 2.4
56KW/h (50Hz)
163
HIGH CAPACITY COMMERCIAL RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
VOLKSWAGEN DEALERSHIP Location: Cabrera de Mar Units installed: High Capacity Zen
THE HIGH-CAPACITY ZEN RANGE FOR COMMERCIAL APPLICATIONS OFFERS MULTIPLE INSTALLATION POSSIBILITIES THAT ARE HIGHLY ENERGY-EFFICIENT AND ENVIRONMENTALLYFRIENDLY. HIGH-CAPACITY EQUIPMENT IS NOTABLE FOR ITS ABILITY TO PROVIDE COMFORT TO PREMISES THAT REQUIRE LARGE AIRFLOWS.
OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN ZEN HOTELS, PUBLIC BUILDINGS HOSPITALS, HEALTH CLINICS AND CENTRES Autism Association of Jeréz (Cádiz), Joan XXIII Hospital (Tarragona), Salamanca Hospital (Salamanca), Sagrado Corazón Health Clinic (Madrid), Museum of Oil (Jaén), Depentya Foundation (Seville), Nuevo Arcangel Football Stadium (Córdoba)
PRIVATE RESIDENCES Residential Complex (Vera), Alpe Property Developments (Tortosa), 134 private residences in East Seville (Seville), Mercainmo Property Developments (Lleida), Residential Complex (Marbella), 503 private residences in Bekinsa Residential Complex (Seville), Las Brisas Hotel (Llanes) BUSINESS CENTRES AND
164
OFFICES Navarrete Offices (La Rioja), Eder Epele offices (Guipúzcoa), Greg Business Centre (Barcelona), Trade Fair (Valladolid), Electric Rooms- Asturiana del Zinz S.A.U. (Asturias), Galvanizados Avilés offices (Avilés), Retevisión Valladolid (Valladolid), Eiffage Energy offices (Ávila), Acofarma offices (Terrassa), Jordi Verna offices (Granollers), Banca March offices (Mal-
lorca), Carrefour offices (Málaga), Barceló Market (Madrid), Day SWRO Desalination offices (Marruecos), Caja Rural Zamora bank offices (Zamora)
RESTAURANTS 100 Montaditos Brewery (Córdoba), Vermut Rofes Restaurants (Reus), La Sureña Brewery (Córdoba), WOK Restaurant (Cáceres)
COMMERCIAL BUILDING Unity Skates shop (Zaragoza), Lecrerc Mall (Málaga), Confecciones Rubio clothes shop (Cádiz, Seville and Córdoba), Aurgi (Madrid), Toyota authorised dealer (Oviedo), Stradivarius (Manresa), Vitaldent dental clinic (different locations), Lacoste (Vilagarcía de Arousa), Lowfit Gym (Seville), Basic Fit Gym (Madrid) , Alimerka Supermarkets (León)
Inspiration, Innovation, Evolution
ENCUENTRO
ZEN HIGH CAPACITY COMMERCIAL
FASHION STORES
Location: Madrid and Seville Units installed: High Capacity Zen Capacity: 100 kW
BASIC FIT GYM
Location: Madrid Units installed: High Capacity Zen Capacity: 140 kW
165
VENTILATION HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY SYSTEMS................................................................168 ERP PRO..........................................................................................170 AZURE..............................................................................................172 STATIC PRESSURE AND EFFICIENCY GRAPHS.............................174
VENTILATION HRV
VENTILATION HEAT RECOVERY SYSTEMS RANGE
HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY
HEAT RECOVERY HEAT RECOVERYSYSTEMS RANGE
Frigicollâ&#x20AC;&#x2122;s heat recovery systems range includes the AZURE and ERP PRO models. These models have been designed to meet Ecodesign 2018 EU Commission legislation requirements. ERP PRO units provide users with high airflows while keeping a high energy efficiency. They also include multiple control options that add more efficiency to the equipment.
ERP PRO HEAT RECOVERY UNITS
The AZURE heat recovery units range includes the most efficient units of FRIGICOLL. They can reach an efficiency of up to 93%. Besides, they include a wide range of control options and communication protocols.
NEW
(Page 170)
RATED AIR FLOW (m3/h)
800
1000
1400
ERP PRO ERP PRO 1200
AZURE HEAT RECOVERY UNITS RATED AIR FLOW (m3/h)
(Page 172)
ERP PRO 2200
NEW 500
700
AZURE 500
AZURE 700
AZURE
168
900
Inspiration, Innovation, Evolution
Frigicoll’s heat recovery systems are highly-efficient cross airflow units. This range of products is wide enough to meet the needs of any premises.
1800
2300
2600
3000
4000
ERP PRO 4200
VENTILATION HRV
ERP PRO 3200
All FRIGICOLL’s heat recovery units provide high energy efficiency, low sound levels and high heat exchange. They also include F6 and F7 filters. The installation of higher density filters or a third filter in the air supply duct is optional.
1400
AZURE 1400
1800
2200
AZURE 2200
2600
3200
AZURE 3200
169
HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY
ERP PRO
NEW
TECHNICAL SPECIFICATIONS ERP PRO 1200 Heating efficiency
ERP PRO 2200 ERP PRO 3200 ERP PRO 4200
EN308: 5ºC outdoors / 25ºC indoors
%
73
73
73
73
Winter: -3ºC outdoors / 22ºC indoors
%
80
82
83
83
Summer: 35ºC outdoors / 24ºC indoors
%
73
74
73
73
Number of fans
2
Fan Type Rated air flow (min.-max.) Unit
ERP 2018, EC motor m³/h
820 (200 - 1140)
1400 (200 - 2000)
2325 (750 - 3300)
3000 (800 - 4240)
Pa
695 (825 - 530)
500 (700 - 240)
505 (800 - 60)
520 (750 - 260)
dB (A)
49
49
53
48
W
500x2
480x2
780x2
1500x2
Width/Height/Depth
mm
1220/500/1850
1368/573/2025
1827/668/2500
2000/668/2500
Weight
Kg
98
155
205
260
V/ph/Hz
220-240/1/50
220-240/1/50
220-240/1/50
380/3/50
Rated static pressure (max.-min.) Sound Pressure Level Max. power input
Power Supply Exchanger material
Aluminium
By-pass damper (Free cooling) Sizes of the duct’s flanges
Yes mm
300x300
Supply / exhaust air filter Working Range
450x450 F7/F6
ºC
Notes: EN 308 conditions, +5°C and 70” RH outdoor air, 25°C and 28% RH indoor air. The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.
170
350x350
From -10ºC to 40ºC
500x500
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS •
Compatible with ECODESIGN 2018 EU Commission regulation.
•
F7 and F6 series filters (optional filters F8 and F9).
•
Unit’s by-pass control.
•
Ventilators with EC motor, ERP 2018.
•
Weekly timer.
•
Standard by-pass gate for ventilation.
•
Reports on filters condition.
•
Up to three air flow speeds adjustable.
•
Instant information on components malfunctions.
•
Reports on filters condition.
•
Optional heat resistors control.
•
ModBus control available.
+ +
VENTILATION HRV
SENSO CONTROLLER:
F6, F8 AND F9 FILTERS (OPTIONAL)
CO2 (OPTIONAL)
Efficiency and air flow graphics on page 174. Senso controller
ACCESSORIES. PREH 1200 ERP
F6 filter 1200 ERP
F8 filter 1200 ERP
F9 filter 1200 ERP
PREH 2200 ERP
F6 filter 2200 ERP
F8 filter E2200 ERP
F9 filter 2200 ERP
PREH 3200 ERP
F6 filter 3200 ERP
F8 filter 3200 ERP
F9 filter 3200 ERP
PREH 4200 ERP
F6 filter 4200 ERP
F8 filter 4200 ERP
F9 filter 4200 ERP
VOD KitAZ (CO2 sensor)
171
HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY
AZURE
NEW
TECHNICAL SPECIFICATIONS AZURE 500 Heating efficiency
AZURE 700 AZURE 1400 AZURE 2200 AZURE 3200
EN308: 5ºC outdoors / 25ºC indoors
%
82
83
82
81
81
Winter: -3ºC outdoors / 22ºC indoors
%
83
84
89
89
89
Summer: 35ºC outdoors / 24ºC indoors
%
78
78
77
79
79
Number of fans
2
Fan Type Rated air flow (min.-max.) Unit
Rated static pressure (max.-min.) Sound Pressure Level Max. power input Width/Height/Depth
Weight Power Supply By-pass damper (Free cooling) Sizes of the duct’s flanges
ERP 2015, EC motor m³/h
500 (200-725)
700 (200-850)
Pa
290 (740-100)
180 (640-50)
350 (690-180)
450 (820-220)
420 (1010-200)
dB (A)
42
47
54
52
54
W
338
340
1000
1000
2000
mm
880/360/1300
1055/360/1500
1355/400/1550
1675/485/1850
1950/567/2125
Kg
80
125
150
185
225
V/ph/Hz
230/1/50
230/1/50
230/1/50
230/1/50
230/1/50
500x300
700x400
AZURE 2200 R
AZURE 3200 R
Yes mm
300x150
400x200
Supply / exhaust air filter Working Range
1400 (500-1700) 2200 (450-2600) 3200 (840-3600)
500x250 F7/F6
ºC
From -20ºC to 40ºC
Notes: EN 308 conditions, +5°C and 70” RH outdoor air, 25°C and 28% RH indoor air. The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.
AZURE 500 R Heating efficiency
AZURE 700 R
EN308: 5ºC outdoors / 25ºC indoors
%
82
83
82
81
81
Winter: -3ºC outdoors / 22ºC indoors
%
83
84
89
89
89
Summer: 35ºC outdoors / 24ºC indoors
%
78
78
77
79
79
Number of fans
2
Fan Type Rated air flow (min.-max.) Unit
Rated static pressure (max.-min.) Sound Pressure Level
ERP 2015, EC motor m³/h
500 (200-725)
700 (200-850)
Pa
290 (740-100)
180 (640-50)
350 (690-180)
450 (820-220)
420 (1010-200)
42
47
54
52
54
W
338
340
1000
1000
2000
Width/Height/Depth
mm
880/360/1300
1055/360/1500
1355/400/1550
1675/485/1850
1950/567/2125
Weight Electrical heater power
Kg
80
125
150
185
225
kW
1.35
1.9
3.8
6
8.8
V/ph/Hz
230/1/50
380/3/50
380/3/50
380/3/50
380/3/50
ºC
8.1
8.1
8.1
8.1
8.2
V/ph/Hz
230/1/50
230/1/50
230/1/50
230/1/50
230/1/50
mm
300x150
400x200
500x250
500x300
700x400
Power Supply Temperature increase
Unit’s power supply By-pass dumper (Free cooling) Sizes of the duct’s flanges
Yes
Supply / exhaust air filter Working Range
F7/F6 ºC
Notes: EN 308 conditions, +5°C and 70” RH outdoor air, 25°C and 28% RH indoor air. The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.
172
1400 (500-1700) 2200 (450-2600) 3200 (840-3600)
dB (A)
Max. power input
Electrical heater
AZURE 1400 R
From -20ºC to 40ºC
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS • Compatible with ECODESIGN 2018 EU Commission regulation.
SENSO PLUS CONTROLLER:
• F7 and F6 series filters (optional filters F8 and F9).
• Weekly timer.
• Low sound levels.
• Unit’s by-pass control. • Reports on filters condition.
• Cross airflow heat exchangers.
• Instant information on components malfunctions.
• High energy efficiency.
• ModBus, EXOline, BACnet and LonWorks control available.
• Ventilators with EC motor, ERP 2015.
• Optional heat resistors control.
+ +
VENTILATION HRV
• Up to three air flow speeds adjustable.
F6, F8 AND F9 FILTERS (OPTIONAL)
CO2 (OPTIONAL)
Senso Plus Controller Efficiency and air flow graphics on page 175.
ACCESSORIES.
ACCESSORIES
ACCESSORIES
F6 filter 500 Azure
F8 filter 500 Azure
F9 filter 500 Azure
F6 filter 700 Azure
F8 filter 700 Azure
F9 filter 700 Azure
F6 filter 1400 Azure
F8 filter 1400 Azure
F9 filter 1400 Azure
F6 filter 2200 Azure
F8 filter 2200 Azure
F9 filter 2200 Azure
F6 filter 3200 Azure
F8 filter 3200 Azure
F9 filter 3200 Azure
VOD KitAZ (CO2 sensor)
173
HEAT RECOVERY SYSTEMS RANGE HEAT RECOVERY
ERP PRO STATIC PRESSURE AND EFFICIENCY GRAPHS ERP PRO 1200 UNIT
ERP PRO 2200 UNIT
ERP PRO 3200 UNIT
ERP PRO 4200 UNIT
NOTE: The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.
174
Inspiration, Innovation, Evolution
AZURE STATIC PRESSURE AND EFFICIENCY GRAPHS AZURE 500
AZURE 700
VENTILATION HRV
AZURE 1400
AZURE 2200
AZURE 3200
NOTE: The calculation of static pressure and air flow is carried out with the filters F7 and F6 installed.
175
AMAZON INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE.........................................................178 INDOOR UNITS......................................................................................184 HIGH WALL.......................................... ...........KAYF.......................188 DOUBLE FLOW CONSOLE...............................KSDF........................190 FLOOR STANDING EXPOSED/CONCEALED.......KS(E)F.......................192 CEILING/FLOOR................................... ............KPCF........................ 194 ONE WAY CASSETTE.......................... ............KCOF.........................196 ART FLUX 360ยบ (600x600) CASSETTE..........KCIF.......................... 198 ART FLUX 360ยบ CASSETTE................. ............KCIBF...................... 200 DUCTS.................................................. ............KPDF........................ 202 STATIC PRESSURE GRAPHS........ ............................................ 204 HIGH PRESSURE DUCTS.................... ............KPDHF.................... 208 STATIC PRESSURE GRAPHS........ ............................................ 210 KAHU.................................................... ............KAHU...................... 214 HOT WATER INDOOR UNIT................. ............KWF......................... 216 OUTDOOR UNITS....................................................................................218 2 PIPES ...................................................................................................222 MINI AMAZON II SINGLE-PHASE.............................. ............KMF DVN2.............. 224 THREE-PHASE.......................................... KMF DTN2.............. 226 AMAZON UNITARIO SIDE DISCHARGE..........KMF........................ 228 AMAZON UNITARIO TOP DISCHARGE DN3...K2UF DN3............... 230 AMAZON UNITARIO TOP DISCHARGE DN4 S...K2UF DN4S............ 232 AMAZON IV PRO................................. ............K2F DN4S............... 236 AMAZON III W..................................... ............K2F DN3W.............. 238 3 PIPES ...................................................................................................240 AMAZON III PRO.................................. ............K3F DN3S............... 242 CHANGEOVER BOXES................... ............KVB......................... 244 DIMENSIONING ................................................................................... 246 DISTANCES AND HEIGHT DIFFERENCES .......................................... 256 KEY INSTALLATIONS .......................................................................... 262
AMAZON INDUSTRIAL VRF
AMAZON INDUSTRIAL VRF RANGE
INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
AMAZON
INDUSTRIAL VRF RANGE
Within the world of air-conditioning, the variable refrigerant flow systems (VRF) are the most versatile in terms of installation possibilities and technological innovation. Thanks to the DC Inverter technology, which varies the frequency of the compressor motor and fan motor of the outdoor unit depending on the total required load, and thanks to electronic expansion valves (both in the outdoor and the indoor units), which regulate the flow of refrigerant depending on the load required for each area, higher levels of efficiency and superior energy savings are achieved. The installation distances available are among the longest in the market, reaching up to 200 meters of equivalent length between the outdoor unit and the farthest indoor unit. The possibilities of the indoor units are endless, not only for the different models available, but also for their power range, which is so wide that it covers from 1.5 kW to 56 kW and allows
“THE BROADEST PRODUCT RANGE ON THE MARKET” for installing up to 64 indoor units in the same cooling circuit. The independent control of indoor units allows each user to choose its own comfort level without interfering with the rest of users. Our wide range of controllers provides end-user with many options to define its level of comfort. They allow installing from a simple individual control (wireless or wired), a centralised control, a computer control and even the possibility of managing the installation from a comprehensive building management system BMS (LONWORKS, MODBUS, BACNET and KNX).
AMAZON UNITARIO TOP DISCHARGE DN4S (2 PIPES) • • • • •
NEW
From 28 to 90 kW Up to 53 indoor units Up to 150% simultaneity Autoaddresing XYE port to connect a centralised control for indoor units DC
INVERTER
OUTDOOR
• Inverter fan motors
+
EFFICIENCY
• Full DC Inverter Compressors
1000 m FOR PIPELINES
• Plate exchanger: In Cooling mode, it improves refrigerant subcooling; in Heating mode, it improves units’ performance by steam injection.
178
Inspiration, Innovation, Evolution
INDOOR UNITS WITH DC INVERTER FAN Most KAYSUN AMAZON indoor units include a DC Inverter motor fan. This development provides units with a much more accurate control, and greater output and energy savings, and it reduces sound (low) pressure. Our units are better suited to the installation requirements of the areas in need of air conditioning, thereby making users' comfort, well-being and energy savings a top priority.
DUCTS
BUILT-IN EXV VALVE
STATIC PRESSURE ADJUSTMENT WITH ROTARY SWITCH (OPTIONAL)
INTERACTIVE DISPLAY
REAR/LOWER OUTLET PANEL
LOW SOUND LEVELS
FRAMES INCLUDE FOR AIR SUPPLY DUCT AND AIR RETURN DUCT
CASSETTE ART FLUX 360º (600x600)
HIGH PRESSURE DUCTS
360° AIRFLOW
HIGH AIRFLOW
FRESH AIR SUPPLY
WIDE POWER RANGE
AMAZON INDUSTRIAL VRF
WALL-MOUNTED
DRAIN PUMP AS STANDARD
CASSETTE ART FLUX 360º
CEILING/FLOOR
360° AIRFLOW
AIR FLOW DISTRIBUTION UP TO 8 METERS
FRESH AIR SUPPLY
DOUBLE INSTALLATION
DRAIN PUMP AS STANDARD
179
INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
HIGH INVERTER TECHNOLOGY The design of the Scroll DC Inverter compressor is based on the highest technology available. With a more compact structure, this compressor provides maximum outputs, increases efficiency and reduces power consumption when the system is working at partial loads. The compressor, which has been optimized for using R410A ecological refrigerant, has received the highest energy classification for both cooling and heating operation - EER and COP. Speed in direct current can be adjusted and results in energy savings of up to 25%, more than any other conventional equipment on the market.
new structure and high energy efficiency at partial load. new serrated design for R410A 50% lighter, thanks to its new design the elaborated design of the compressor allows a more centralised magnetic flow it uses a DC motor inverter
COMPENSATION TECHNOLOGY FOR OIL DISTRIBUTION
Outdoor units ensure individualised control and homogeneous distribution of oil between modules so that the compressor is able to provide a smooth and reliable performance. The oil balance and outlet pipes send the compressor's remaining oil to a system that will distribute it uniformly to the other compressors.
The oil centrifuge separator, is capable to work with an efficiency over 99%, by sending oil to the compressors on time and effectively in order to ensure that they have the correct amount of oil. This system is designed to extend the working life of KAYSUN units' compressors as much as possible.
HIGH-PRESSURE GAS
pipe to condenser
TUBERÍA DE ENTRADA
High-performance 99% oil separator oil balance port between modules DISCHARGE PIPE
TUBERÍA DE DESCARGA
CARTER DE ACEITE
OIL CLEARING PIPE II OIL BALANCE PIPE BETWEEN MODULES III
TUBERÍA DE COMPENSACIÓN DE ACEITE
OIL BALANCE PIPE I
pipe from indoor units
compressor
SUCTION PIPE
CENTRALISED WINDING
The DC Inverter compressor's technology used in KAYSUN's AMAZON units, are fitted with centralised winding instead of distributing winding. This type of winding consists of very powerful magnets that allow for increasing the force of rotation and therefore, the compressor's effectiveness. EFFECTIVENESS OF THE COMPRESSOR
70% reduction New DC motor Common DC motor
20
180
40
60
80
100
ROTOR SPEED (S-1)
Dispensing coil
Central coil
Inspiration, Innovation, Evolution
SMART SOFT-STARTER TECHNOLOGY
DC INVERTER compressors characterise by a soft, low frequency and low power consumption starter. This reduces the risk of overloading the power grid and prevents excessive consumption peaks during outdoor unit starting.
STARTING FREQUENCY (%)
600
(*) Comparison between starting with an inverter starter and with a conventional starter. 500
400
FLUCTUATION TEMPERATURE (ºC)
300
200 Inverter
1
2 Starting of INVERTER Starting of
100
ON/OFF
On/off switch TIME (H) EFFECTIVENESS OF THE COMPRESSOR
1
2
3
4
5
TIME (SEC)
6
FAN Our units are extremely quiet and efficient thanks to their DC Inverter fan, which allows for reducing noise level from 2-5 dB (A) and increases the airflow from 1000 to 4000m3/h.
PROPELLER FAN
The new helical shape of the fun's blades supplies a large volume of air whilst reducing vibrations and resistance to a minimum.
60 Pa
OPTIMISED AIRFLOW OUTLET
AMAZON INDUSTRIAL VRF
The efficiency of the fan’s airflow has been improved thanks to the fan’s new design. This, in combination with the DC Inverter motor, allows for a static pressure increase of up to 60 Pa, a pressure loss decrease and a 10% optimization of the airflow. DC INVERTER MOTOR
The fan’s DC Inverter motor consumes minimal energy since the fan speed can be regulated depending on the power demand and the operating pressure of the cooling circuit. EFFECTIVENESS(%)
100
80
ROTOR SPEED (PPM)
60
1000
45% increase
40 18 LEVELS of speed adjustment
20 200 200
1000
MOTOR SPEED (RPM)
SYSTEM PRESSURE (Pa)
181
INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
EASY INSTALLATION AND MAINTENANCE The outdoor units' design allows for an easy installation and maintenance. The new electrical box includes an inspection window in the main electronic board that allows for a straightforward access from outside the equipment. The compressor is located just opposite the electric box to make access easier when its replacement is required. WORKING RANGE
EXCHANGER OPTIMIZATION
Thanks to the new DC Inverter technology, the AMAZON range offers increased operability for cooling and heating modes within a much larger working range, thereby ensuring a perfect airconditioning control during all seasons of the year.
The battery of the 12, 20 and 22 HP models of AMAZON IV has been optimised to reduce their volume by adding an extra row to its large surface. Besides, the delta-shaped heat exchanger helps to improve subcooling.
48 ยบC
21 ยบC
OPERATING MODE LOCKING FUNCTION (2 PIPES) Outdoor temperature
-5 ยบC
From a switch located at the outdoor unit's electronic board, user may select 6 different operating modes for the cooling system:
Outdoor temperature
-20 ยบC
* For further information on AMAZON IV for other ranges, please check temperature tables.
AUTO-ADDRESS OF THE INDOOR UNITS
There are two address setting options for indoor units:
1. Heating mode priority (default). 2. Cooling mode priority. 3. Cooling mode only. 4. Heating mode only. 5.- Unit addressed as no. 63 determines the operating mode. 6. Those units with the same operating mode forming a majority shall determine the operation mode of the whole system.
Automatic: Using the SW6 switch of the outdoor unit (deactivated by default), the outdoor unit automatically distributes the address to the indoor units with no manual adjustment. ROTARY AND CONSTANTLY VENTILATED ELECTRICAL BOX
Manual: The address of all indoor units can be consulted and modifier using the KI-02.3 S wireless controller or the KCT-02.1 SR wired controller.
SW6
The electrical box of the AMAZON IV units, apart from providing boards' electronic parts with constant ventilation by means of a heat dissipation system, is completely rotary in order to facilitate the access inside the unit.
KI-02.3 S controller Wall-mounted No 1
Wall-mounted No 2
OUTDOOR UNIT
CENTRALISED CONTROLLER WIRING INDOOR UNITS
Wall-mounted No 3
All AMAZON systems have an XYE port in the outdoor unit, allowing the three wires of the centralised control cable between the indoor units to be dispensed with.This means that it is possible to connect directly to the XYE port. Wall-mounted No 4
XYE
MODULES AUTOMATIC REDUNDANCY
AMAZON's intelligent control system, defines the boot priority of the module according to the system load, and balances its operating time to optimise reliability and working life of the unit.
182
PORT DE CONNEXION
Inspiration, Innovation, Evolution
A NOD TO ENVIRONMENT WORKING RANGE
The AMAZON units have one of the highest energy efficiency ratings in the market, with very high EER and COP scores. Furthermore, since outdoor units are modular, units with the best EER/COP scores can be combined to provide higher energy efficiency in facilities that require large cooling capacity.
8 / 10 / 12
ECOLOGICAL DESIGN
AMAZON INDUSTRIAL VRF
Kaysun not only offers the most technologically advanced products of the market, but also makes every single effort to produce them under the strictest ecological standards in order to ensure a minimal negative impact on the environment.
14 / 16 / 18 / 20 / 22
R-410A REFRIGERANT
The Amazon system uses the environmentallyfriendly refrigerant R410A, which, in addition to having high efficiency and energy savings it is characterised for being respectful of the ozone layer and helps us to reduce the impact on the environment.
ECOLOGICAL DESIGN
92% recyclable
Energy saving
183
INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
184
Inspiration, Innovation, Evolution
INDOOR UNITS
AMAZON INDUSTRIAL VRF
TECHNICAL SPECIFICATIONS
185
INDUSTRIAL VRF RANGE INDOOR UNITS
INDOOR UNITS RANGE POWER kW
1.5
2.2
WALL-MOUNTED
2.8
3.6
4.5
5.6
KAYF-28 DN3.0
KAYF-36 DN3.0
KAYF-45 DN3.0
KAYF-56 DN3.0
KSDF-36 DN2.3
KSDF-45 DN2.3
(Page 188)
KAYF-22 DN3.0
DOUBLE FLOW CONSOLE
(Page 190) KSDF-28 DN2.3
FLOOR STANDING EXPOSED/CONCEALED
(Page 192) KS(E)F-56 DN2.3 KSEF-56 DN2.3
CEILING / FLOOR
(Page 194) KPCF-56 DN3.0
ONE WAY CASSETTE
(Page 196)
KCOF-22 DN2.4
KCOF-36 DN2.4
CASSETTE ART FLUX 360ยบ (600x600) KCIF-15 DN3.0
KCIF-28(22) DN3.0
(Page 198) KCIF-36 DN3.0
KCIF-45 DN3.0
CASSETTE ART FLUX 360ยบ (Page 200) KCIFB-56 DN3.0
DUCTS
(Page 202)
KPDF-15 DN3.0
KPDF-22 DN3.0
KPDF-28 DN3.0
HOT WATER INDOOR UNIT
POWER kW
7.1
HIGH PRESSURE DUCTS
KAHU
KPDF-45 DN3.0
KPDF-56 DN3.0
11.2
14.0
16.0
KPDHF-140 DN3.0
KPDHF-160 DN3.0
(Page 216)
9.0
KPDHF-71 DN3.0
KPDF-36 DN3.0
KPDHF-90 DN3.0
(Page 208) KPDHF-112 DN3.0
(Page 214) KAHU-200.2
186
Inspiration, Innovation, Evolution
7.1
8.0
9.0
10.0
11.2
12.5
14.0
16.0
18.0
56.0
60.0
KAYF-80 DN3.0
KS(E)F-80 DN2.3
KPCF-90 DN3.0
KPCF-140 DN3.0
KCIFB-71 DN3.0
KCIFB-80 DN3.0
KPDF-71 DN3.0
KPDF-80 DN3.0
KCIFB-100 DN3.0
KPDF-90 DN3.0
KCIB-112 DN3.0
KCIF-140 DN3.0
KPDF-112 DN3.0
KPDF-140 DN3.0
AMAZON INDUSTRIAL VRF
KCOF-71 DN2.4
KWF-140
DOMESTIC HOT WATER
20.0
KPDHF-200 DN3.0
25.0
KPDHF-250 DN3.0
28.0
KPDHF-280 DN3.0
KAHU-360.2
36.0
40.0
KPDHF-400 DN2.4
45.0
KPDHF-450 DN2.4
50.0
KPDHF-560 DN2.4
KAHU-560.2
187
INDUSTRIAL VRF RANGE INDOOR UNITS
WALL-MOUNTED GENERAL CHARACTERISTICS The main features of our wall-mounted units are a DC INVERTER fan and the smart design of their panel. They include a LED display located at the centre of the unit that provides it with a modern design by using the most advanced technology in the market. •
Low noise level, creating a peaceful and comfortable atmosphere.
•
The swing angle of the louvers may reach up to 90º.
•
Built-in expansion valve.
•
ON/OFF dry contact and 220V alarm signal output.
•
DC INVERTER fan included
•
Left inlet for installation pipes (front view)
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS MODEL
KAYF-22 DN3.0
KAYF-28 DN3.0
KAYF-36 DN3.0
KAYF-45 DN3.0
KAYF-56 DN3.0
KAYF-80 DN3.0
Cooling capacity
kW
2.2
2.8
3.6
4.5
5.6
8
Cooling capacity
Kcal/h
1892
2408
3096
3870
4816
6880
Heating Capacity
kW
2.4
3.2
4
5
6.3
9
Heating Capacity
Kcal/h
2064
2752
3440
4300
5418
Power input
7740
33 53
W
8
9
19
19
27
Indoor airflow
m3/h
422/393/356
417/370/316
656/573/488
594/507/424
747/648/547
1195/1005/809
Sound pressure
dB (A)
29
29
30
31
34
36
Width/Height/Depth
mm
835/280/203
835/280/203
990/315/223
990/315/223
990/315/223
1194/343/262
Net weight
Kg
8.4
9.5
11.4
12.8
12.8
17
Liquid pipe diameter
mm (inch")
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø6.35 (1/4")
ø9.52 (3/8")
ø9.52 (3/8")
Gas pipe diameter
mm (inch")
ø12.7 (1/2")
ø12.7 (1/2")
ø12.7 (1/2")
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
Drain tube diameter
mm
Ø16
Ø16
Ø16
Ø16
Ø16
Ø16
Power wiring (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power cord
All AMAZON indoor units accept R-410A refrigerant.
188
Inspiration, Innovation, Evolution
DC
INVERTER
R-410A
+ +
INDOOR
DC INVERTER FAN
LOW SOUND LEVEL
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the â&#x201A;¬ price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
189
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
INDUSTRIAL VRF RANGE INDOOR UNITS
DOUBLE FLOW CONSOLE GENERAL CHARACTERISTICS With a modern and cutting-edge design, the consoles can be gracefully incorporated into any space. Their reduced depth, provides the unit with an external flexible design that adapts to every installation, from floor standing installations to low wallmounted installations, without affecting their capacity. •
Thanks to their four return air inlets and two outlets, the unit reach the selected temperature much faster.
•
DC Inverter fan motor.
•
Low starting power and precise room temperature adjustment.
•
The electronic expansion valve is integrated inside the indoor unit.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KSDF-28 DN2.3
MODEL
KSDF-36 DN2.3
KSDF-45 DN2.3
Cooling capacity
kW
2.8
3.6
4.5
Cooling capacity
Kcal/h
2408
3096
3870
Heating Capacity
kW
3.2
4
5
Heating Capacity
Kcal/h
2752
3440
W
25
25
45
Indoor airflow
m3/h
510/430/229
510/430/229
660/512/400
Sound pressure
dB (A)
27
27
36
Width/Height/Depth
mm
700/600/210
700/600/210
700/600/210
Net weight
Kg
15
15
15
Liquid pipe diameter
mm (inch")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Gas pipe diameter
mm (inch")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Drain tube diameter
mm
Ø16
Ø16
Ø16
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Power input
Power supply
All AMAZON indoor units accept R-410A refrigerant.
190
4300 33
Inspiration, Innovation, Evolution
DC
INVERTER
R-410A
+ +
INDOOR
ACCURATE ROOM TEMP. ADJUSTMENT
DC INVERTER FAN
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the â&#x201A;¬ price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
191
INDUSTRIAL VRF RANGE INDOOR UNITS
FLOOR STANDING EXPOSED/CONCEALED GENERAL CHARACTERISTICS The streamlined design of this unit, due mainly to its reduced depth, is the perfect solution for saving space and adapting to every installation, from wall-mounted to floor standing, whether totally or partially recessed, thereby gracefully harmonising with the interior design of the room.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO
•
Built-in expansion valve.
•
ON/OFF dry contact and 220V V alarm signal output.
•
Its 12Pa static pressure helps move air supply.
2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KSEF-56 DN2.3
MODEL
KS(E)F-56 DN2.3
KS(E)F-80 DN2.3
Cooling capacity
kW
5.6
5.6
8
Cooling capacity
Kcal/h
4816
4816
6880
Heating Capacity
kW
6.3
6.3
9
Heating Capacity
Kcal/h
5418
5418
7740
W
88
88
130
Indoor airflow
m3/h
1150/970/830
1150/970/830
1380/1100/870
Sound pressure
dB (A)
31
31
33
Width/Height/Depth CONCEALED
mm
-
1500/596/225
1500/596/225
Width/Height/Depth EXPOSED
mm
1345/544/212
1345/544/212
1380/1100/870
Net weight CONCEALED
Kg
-
42
44
Net weight EXPOSED
Kg
41
41
42.5
Liquid pipe diameter
mm (inch")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Gas pipe diameter
mm (inch")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Drain tube diameter
mm
Ø25
Ø25
Ø25
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Power input
Power supply
All AMAZON indoor units accept R-410A refrigerant.
192
Inspiration, Innovation, Evolution
R-410A
CONCEA
LED
EXPOS
ED
+
12 PA STATIC PRESSURE
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the â&#x201A;¬ price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
193
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
INDUSTRIAL VRF RANGE INDOOR UNITS
CEILING / FLOOR GENERAL CHARACTERISTICS Ceilling/Floor VRF indoor unit with DC INVERTER motors. Its compact design helps integrating the unit into every environment. As its name suggests, these units can be installed on the ceiling in horizontal position and on the floor in vertical position. The design of their condensation water tray so permits.
MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO
•
Built-in expansion valve.
•
ON/OFF dry contact and 220V V alarm signal output.
•
Smoother air flow with less turbulences. Thanks to the multi blades fan and the design of its louvers, the airflow is softer and more comfortable.
•
COMPATIBLE WITH
2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
Indoor units with DC INVERTER fan.
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KPCF-56 DN3.0
MODEL
KPCF-90 DN3.0
KPCF-140 DN3.0
Cooling capacity
kW
5.6
9
14
Cooling capacity
Kcal/h
4816
7740
12040
Heating Capacity
kW
6.3
10
15.5
Heating Capacity
Kcal/h
5418
8600
13330
W
94
126
130
Indoor airflow
m3/h
930/830/720
1280/1170/1050
1890/1700/1580
Sound pressure
dB (A)
36
40
42
Width/height/depth (floor installation)
mm
990/660/203
1280/660/203
1670/680/244
Net weight
Kg
27
33.5
49
Liquid pipe diameter
mm (inch")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Gas pipe diameter
mm (inch")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Drain tube diameter
mm
Ø25
Ø25
Ø25
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Power input
Power supply All AMAZON indoor units accept R-410A refrigerant.
194
Inspiration, Innovation, Evolution
DC
INVERTER
R-410A
+
INDOOR
DC INVERTER FAN
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the â&#x201A;¬ price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
195
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
INDUSTRIAL VRF RANGE INDOOR UNITS
ONE WAY CASSETTE GENERAL CHARACTERISTICS ONE WAY CASSETTE. Stands at just 153mm in height, depending on the capacity of the unit. It has a compact and light design, making it very easy to install and maintain in any space. These units are perfectly merged with the ceiling, creating a clean and subtile aesthetic. •
The control box is built into the body of the unit. This saves space and allows facilitates maintenance.
•
Standard condensation pump.
•
It has a very reduced height, making it ideal for very low suspended ceilings.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KCOF-22 DN2.4
MODEL
KCOF-36 DN2.4
KCOF-71 DN2.4
Cooling capacity
kW
2.2
3.6
7.1
Cooling capacity
Kcal/h
1892
3096
6106
Heating Capacity
kW
2.6
4
8
Heating Capacity
Kcal/h
2236
3440
6880
W
41
41
55
Indoor airflow
m3/h
523/404/275
573/456/315
933/749/592
Sound pressure
dB (A)
30
34
37
Width/Height/Depth
mm
1054/153/425
1054/153/425
1275/189/450
Net weight
Kg
12.5
13
19.5
Width/Height/Depth (panel)
mm
1180/25/465
1180/25/465
1350/25/505
Net weight (panel)
Kg
3.5
3.5
4
Liquid pipe diameter
mm (inch")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø9.53 (3/8")
Gas pipe diameter
mm (inch")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø15.9 (5/8")
Drain tube diameter
mm
Ø25
Ø25
Ø25
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Power input
Power supply
2
All AMAZON indoor units accept R-410A refrigerant.
196
Inspiration, Innovation, Evolution
R-410A
+
STANDARD CONDENSATION PUMP
+
UP TO 153 MM IN HEIGHT
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the â&#x201A;¬ price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
197
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
INDUSTRIAL VRF RANGE INDOOR UNITS
ART FLUX 360º (600x600) CASSETTE GENERAL CHARACTERISTICS With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact and lighter, less space and equipment are needed to install it. They can be completely integrated into any space, including shallow ceilings, without sticking out. •
On/Off dry contact and 220 V alarm output.
•
Integrated control box inside the unit's body; it saves space and allows for ceiling installation.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
•
Ducts pre-installation holes, to supply air to adjoining rooms.
•
Electronic expansion valve kit on one side of the unit.
•
Indoor units with DC INVERTER FAN.
•
Fresh air possibility to enter directly into the room through a preinstallation hole located at the unit’s body.
•
Standard condensation pump.
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KCIF-15 DN3.0
MODEL
KCIF-28(22) DN3.0 ** KCIF-36 DN3.0
KCIF-45 DN3.0
Cooling capacity
kW
1.5
2.8(×2.2)
3.6
4.5
Cooling capacity
Kcal/h
1290
2408(×1892)
3096
3870
Heating Capacity
kW
1.7
3.2(×2.6)
4
5
Heating Capacity
Kcal/h
1462
2742(×2236)
3440
4300
W
14
15
21
21
Indoor airflow
m3/h
526/449/364
576/503/405
604/516/400
604/516/400
Sound pressure
dB (A)
21
22
27
27
Width/Height/Depth
mm
570/260/570
570/260/570
570/260/570
570/260/570
Net weight
Kg
16
16
17.5
17.5
Width/Height/Depth (panel)
mm
648/50/648
648/50/648
648/50/648
648/50/648
Panel net weight
Kg
2.5
2.5
2.5
2.5
Liquid pipe diameter
mm (inch")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Gas pipe diameter
mm (inch")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Drain tube diameter
mm
Ø25
Ø25
Ø25
Ø25
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power input
Power supply
All AMAZON indoor units accept R-410A refrigerant. **KCIF-28 DN3.0 model is compatible with KCIF-22 DN3.0 model.
198
Inspiration, Innovation, Evolution
DC
INVERTER
R-410A
+ +
INDOOR
DC INVERTER FAN
360º AIR DIFFUSION
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
199
INDUSTRIAL VRF RANGE INDOOR UNITS
CASSETTE ART FLUX 360º GENERAL CHARACTERISTICS With its new 360º panel and DC INVERTER fan, the Art Flux Cassette unit provides even, fast and far-reaching air-conditioning control, without leaving dead zones. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out. •
Electronic expansion valve kit on one side of the unit.
•
On/Off dry contact and 220 v Alarm output.
•
Integrated control box inside the unit's body; it saves space and allows for ceiling installation.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
•
Ducts pre-installation holes, to supply air to adjoining rooms.
•
Fresh air possibility to enter directly into the room through a preinstallation hole located at the unit’s body.
•
Indoor units with DC INVERTER FAN.
•
Standard condensation pump.
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KCIBF-56 DN3.0
MODEL
KCIBF-71 DN3.0
KCIBF-80 DN2.3
KCIBF-100 DN3.0
KCIBF-112 DN3.0
KCIBF-140 DN3.0
Cooling capacity
kW
5.6
7.1
8
10
11.2
14
Cooling capacity
Kcal/h
4816
6106
6880
8600
9632
12040
Heating Capacity
kW
6.3
8
9
11
12.5
15
Heating Capacity
Kcal/h
5418
6880
7740
9460
10750
12900
W
31
46
48
110
110
120
33 1727/1426/1220
Power input Indoor airflow
m3/h
1029/857/704
1200/996/748
1264/1055/811
1596/1239/1030
1596/1239/1030
Sound pressure
dB (A)
34
34
35
36
36
Width/Height/Depth
mm
904/230/840
904/230/840
904/230/840
904/300/840
904/300/840
904/300/840
Net weight Width/Height/Depth (panel) Panel net weight
Kg
24
24
24
27.4
27.4
30
mm
950/55/950
950/55/950
950/55/950
950/46/950
950/46/950
950/46/950
Kg
5
5
5
5
5
5
Liquid pipe diameter
mm (inch")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Gas pipe diameter
mm (inch")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Drain tube diameter
mm
Ø32
Ø32
Ø32
Ø32
Ø32
Ø32
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
All AMAZON indoor units accept R-410A refrigerant.
200
33
35
Inspiration, Innovation, Evolution
DC
INVERTER
R-410A
+ +
INDOOR
DC INVERTER FAN
360º AIR DIFFUSION
KI-02.3 S
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
CHOOSE YOUR
CONTROLLER
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
AMAZON INDUSTRIAL VRF
(*) RECOMMENDED
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
BMS AND SOFTWARE
K01-LON
K02-MODBUS
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
K01-KNX
K01-WIFI
201
INDUSTRIAL VRF RANGE INDOOR UNITS
Ducts GENERAL CHARACTERISTICS The VRF AMAZON Duct units with DC INVERTER fan motors have a compact and versatile design that allows for adapting to every false ceiling installation. We truly believe this is a thorough product.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
• Units with DC Inverter fan motor.
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
• Broad range of capacities: from 1.5 kW to 14 kW, eleven models in total. • Double return system possibility (rear inlet or lower inlet).
AMAZON IV PRO 2 PIPES see pag. 236
• Pre-installed entry in the unit’s body for fresh air. • Flanges for fitting outlet and return ducts.
AMAZON III W
• Compatible with AIRZONE air-conditioning zoning systems.
2 PIPES see pag. 238
• It contains a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms with a limited false ceiling.
AMAZON III PRO 3 PIPES see pag. 242
• On/Off dry contact and Alarm 220 V output. • Receiver detaches up to 10 meters (optional cable). • Possibility to change available static pressure by means of a dipswitch. • Standard condensation pump.
33
TECHNICAL SPECIFICATIONS KPDF-15 DN3.0
MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply
kW Kcal/h kW Kcal/h W m3/h Pa dB (A) mm Kg mm (inch") mm (inch") mm mm2 mm2 V / F / Hz
All AMAZON indoor units accept R-410A refrigerant.
202
KPDF-22 DN3.0
KPDF-28 DN3.0
KPDF-36 DN3.0
33
KPDF-45 DN3.0
1.5
2.2
2.8
3.6
4.5
1290
1892
2408
3096
3870
1.7
2.6
3.2
4
5
1462
2236
2752
3440
4300
39
39
39
45
58
600/550/460
600/550/460
600/550/460
660/460/400
850/800/650
40
60
60
60
60
31
31
31
33
33
740/210/500
740/210/500
740/210/500
740/210/500
960/210/500
17.5
17.5
17.5
17.5
22.5
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø6.35 (1/4")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø25
Ø25
Ø25
Ø25
Ø25
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Inspiration, Innovation, Evolution
A
DC
INVERTER
R-410A
+
INDOOR
B
DC INVERTER FAN
+
MANUAL PRESSURE ADJUSTMENT AVAILABLE
Compatible with
KCT-02.1 SR (*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
For further information, please see our Controllers Range
INDIVIDUAL
KI-02.3 S
CHOOSE YOUR
CONTROLLER
CENTRALISED
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
K01-KNX
K01-WIFI
K01-LON
K02-MODBUS
MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply
K01 MODBUS 1/4/8/32
KPDF-56 DN3.0
K01-BACNET
KPDF-71 DN3.0
KAYNET CONTROL
KPDF-80 DN3.0
KPDF-90 DN3.0
KPDF-112 DN3. 0
KPDF-140 DN3.0
5.6 7.1 8 9 11.2 14 kW 4816 6106 6880 7740 9632 12040 Kcal/h 6.3 8 9 10 12.5 15.5 kW 5418 6880 7740 8600 10750 13330 Kcal/h 89 89 98 108 178 204 W 3 980/920/740 1350/1250/1050 1700/1400/1100 1800/1400/1150 2200/1900/1600 2800/2300/1900 m /h 60 60 110 110 120 170 Pa 33 34 37 37 37 38 dB (A) 960/210/500 1180/210/500 1180/270/775 1180/270/775 1180/270/775 1240/300/865 mm 22.5 28 38 40 40 49 Kg ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") ø9.52 (3/8") mm (inch") ø9.52 (3/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") Ø15.9 (5/8") mm (inch") Ø15.9 (5/8") Ø25 Ø25 Ø25 Ø25 Ø25 Ø25 mm (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 mm2 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 mm2 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
203
AMAZON INDUSTRIAL VRF
BMS AND SOFTWARE
KPDF-90 DN2.4
INDUSTRIAL VRF RANGE INDOOR UNITS
Ducts STATIC PRESSURE GRAPHS KPDF-15 DN3.0
KPDF-22 DN3.0 - KPDF-28 DN3.0
KPDF-36 DN3.0
204
Inspiration, Innovation, Evolution
A
DC
INVERTER
R-410A
INDOOR
B
KPDF-45 DN3.0
AMAZON INDUSTRIAL VRF
KPDF-56 DN3.0
KPDF-71 DN3.0
205
INDUSTRIAL VRF RANGE INDOOR UNITS
Ducts STATIC PRESSURE GRAPHS KPDF-80 DN3.0
KPDF-90 DN3.0
206
Inspiration, Innovation, Evolution
A
DC
INVERTER
R-410A
INDOOR
B
KPDF-112 DN3.0
AMAZON INDUSTRIAL VRF
KPDF-140 DN3.0
207
INDUSTRIAL VRF RANGE INDOOR UNITS
HIGH PRESSURE DUCTS GENERAL CHARACTERISTICS As their name suggest, these duct units supply higher static pressure, which allows for a more flexible design. They adapt to every installation space, even those with very high ceilings.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224-226
AMAZON UNITARIO
•
On/Off dry contact and Alarm 220 V output.
•
The expansion valve is integrated inside the 16 kW models; models over 20 kW have expansion valve fitted on the side of the unit.
•
Compatible with AIRZONE air-conditioning zoning systems.
•
Units with high airflows.
•
Power range from 7.1 kW to 56 kW.
•
Units with a DC INVERTER fan motor (a power range from 7.1 kW to 28 kW).
•
Condensation pump not included.
•
Air suction filter included in the whole range.
2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
AMAZON III PRO 3 PIPES see pag. 242
TECHNICAL SPECIFICATIONS KPDHF-71 DN3.0
MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply
kW Kcal/h kW Kcal/h W m3/h Pa dB (A) mm Kg mm (inch") mm (inch") mm mm2 mm2 V / F / Hz
All AMAZON indoor units accept R-410A refrigerant.
208
KPDHF-90 DN3.0
KPDHF-112 DN3.0
KPDHF-140 DN3.0
KPDHF-160 DN3.0
7.1
9
11.2
14
16
6106
7740
9632
12040
13760
8
10
12.5
16
17
6880
8600
10750
13760
14620
180
220
380
420
700
1800/1600/1500
2200/1900/1700
2600/2200/1950
3600/3100/2800
4400/3400/3100
210
210
210
220
220
42
45
45
48
50
952/420/690
952/420/690
952/420/690
1300/420/690
1300/420/690
41
47
47
68
78
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
ø9.52 (3/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø25
Ø25
Ø25
Ø25
Ø25
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
220-240/1/50
Inspiration, Innovation, Evolution
R-410A
+
FROM 7.1 KW TO 28 KW DC INVERTER FAN MOTORS
+
HIGH AIRFLOWS
Compatible with
KCT-02.1 SR (*) RECOMMENDED
PRICE CALCULATION BASED ON THE RECOMMENDED CONTROLLER If you want a different controller, you should add to the € price for the set the price difference between the recommended controller and the selected controller.
CONTROLS
For further information, please see our Controllers Range CENTRALISED
INDIVIDUAL
KI-02.3 S
CHOOSE YOUR
CONTROLLER
KCT-02.1 SR
KC-02.1 H
KC-01 S
KCCT-64 I (B)
NEW
NEW
KCCT-64 IPS
KCCT-384 IPS
KCC-64 WEB
K01-KNX
K01-WIFI
K01-LON
K02-MODBUS
MODEL Cooling capacity Cooling capacity Heating Capacity Heating Capacity Power input Indoor airflow Maximum static pressure Sound pressure Width/Height/Depth Net weight Liquid pipe diameter Gas pipe diameter Drain tube diameter Power cord (10 m max.) Shielded communication wires Power supply
K01 MODBUS 1/4/8/32
K01-BACNET
KAYNET CONTROL
KPDHF-200 KPDHF-250 KPDHF-280 KPDHF-400 KPDHF-450 KPDHF-560 DN3.0 DN3.0 DN3.0 DN2.4 DN2.4 DN2.4 20 25 28 40 45 56 kW 17200 21500 24080 34400 38700 48160 Kcal/h 22.5 26 31.5 45 50 63 kW 19350 22360 27090 38700 43000 54180 Kcal/h 800 800 800 2700 2700 3400 W 6000/5800/5400 6000/5800/5400 6000/5800/5400 7800/6500/5500 7800/6500/5500 11000/9000/7500 m3/h 250 250 250 200 200 200 Pa 50 50 50 56 56 57 dB (A) 1443/470/810 1443/470/810 1443/470/810 1970/668/902.5 1970/668/902.5 1970/668/902.5 mm 108 108 108 232 232 235 Kg Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø12.7 (1/2") Ø15.9 (5/8") mm (inch") ø9.52 (3/8") Ø22.2 (7/8") Ø22.2 (7/8") Ø28.6 (1 1/8”) Ø28.6 (1 1/8”) Ø28.6 (1 1/8”) mm (inch) Ø22.2 (7/8") Ø32 Ø32 Ø32 Ø32 Ø32 Ø32 mm (2+T)x2.5 (2+T)x2.5 (2+T)x2.5 (2+T)x4 (2+T)x4 (2+T)x4 mm2 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 3x0.75 mm2 V / F / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50
209
AMAZON INDUSTRIAL VRF
BMS AND SOFTWARE
INDUSTRIAL VRF RANGE INDOOR UNITS
HIGH PRESSURE DUCTS STATIC PRESSURE GRAPHS KPDHF-71 DN3.0
KPDHF-90 DN3.0
KPDHF-112 DN3.0
210
Inspiration, Innovation, Evolution
R-410A
KPDHF-140 DN3.0
AMAZON INDUSTRIAL VRF
KPDHF-160 DN3.0
KPDHF-200 DN3.0
211
INDUSTRIAL VRF RANGE INDOOR UNITS
HIGH PRESSURE DUCTS STATIC PRESSURE GRAPHS KPDHF-250/280 DN3.0
KPDHF-400/450 DN2.4
212
Inspiration, Innovation, Evolution
R-410A
AMAZON INDUSTRIAL VRF
KPDHF-560 DN2.4
213
INDUSTRIAL VRF RANGE INDOOR UNITS
KAHU GENERAL CHARACTERISTICS This is an interface that allows you to connect a UTA (air terminal unit) with a direct-expansion coil to the VRF system. This unit shall be treated like an additional indoor unit within the VRF system. •
Can be installed on direct expansion batteries up to 56 Kw.
•
It consists of an electrical control box, electronic expansion valve, cables and control sensors.
•
It includes an XYE port to connect to a centralised indoor unit control.
•
On/Off dry contact and 220 V Alarm output.
•
Compatible only with 2 ducts outdoor units.
•
More than one unit can be connected at the same time to increase the connectable power.
COMPATIBLE WITH MINI AMAZON 2 PIPES see pag. 224 226
AMAZON UNITARIO 2 PIPES see pag. 228-230-232
AMAZON IV PRO 2 PIPES see pag. 236
AMAZON III W 2 PIPES see pag. 238
TECHNICAL SPECIFICATIONS MODEL
KAHU-200.2
KAHU-360.2
KAHU-560.2
Cooling capacity*
kW
From 9 to 20
From 21 to 36
From 37 to 56
Width/Height/Depth
mm
350/375/150
350/375/150
350/375/150
Net weight
Kg
8.4
8.7
8.9
Liquid pipe diameter
mm (inch")
ø9.52 (3/8")
Ø12.7 (1/2")
Ø15.9 (5/8")
Gas pipe diameter
mm (inch")
ø9.52 (3/8")
Ø12.7 (1/2")
Ø15.9 (5/8")
Power cord (10 m max.)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
V / F / Hz
220-240/1/50
220-240/1/50
220-240/1/50
Power supply
* Power can be adjusted by a dip switch located at the electric board.
214
Inspiration, Innovation, Evolution
R-410A
1
ELECTRICAL CONTROL BOX
2
KCT-02.1 SR BUILT-IN WIRED CONTROL
KCT-02.1 SR
IBLE WI TH PAT OM
ITH
TS
C U D 2
LE W
ONL YC
STANDARD
ON LY C PATIB OM
ELECTRIC EXPANSION VALVE
4
AMAZON INDUSTRIAL VRF
3
TEMPERATURE CABLES AND SENSORS
INSTALLATION EXAMPLE KAHU OUTDOOR UNIT
PQE Liquid cooling pipeline
INDOOR UNITS
Gas cooling pipeline
MARKET CLIMATE CONTROL WITH DIRECT EXPANSION BATTERY
215
INDUSTRIAL VRF RANGE INDOOR UNITS
HOT WATER INDOOR UNIT GENERAL CHARACTERISTICS KAYSUN has an indoor unit specific for AMAZON systems that is able to produce hot water. •
For domestic hot water and heating.
•
Water outlet temperature between 25ºC and 45ºC.
TECHNICAL SPECIFICATIONS KWF-140 ACS
MODEL Heating capacity
kW
14
Heating Capacity
Kcal/h
12040
Power consumption
W
1
Water outlet temperature range
ºC
25-45
Working limits with cold outdoor temp.
ºC
-5ºC to 35ºC
Working limits with heat outdoor temp.
ºC
-5ºC to 35ºC
Water inlet pipe diameter
Inches
DN25
Water outlet pipe diameter
Inches
DN25
Design airflow
m³/h
2.4 (from 2 to 3)
Inlet liquid pipe diameter
mm (inch")
ø9.52 (3/8")
Outlet liquid pipe diameter
mm (inch")
Ø15.9 (5/8")
dB (A)
26
Width/Height/Depth
mm
500/900/373
Net weight
Kg
55
Sound pressure
Power cord (10 m max.)
mm
2
Shielded communication wires
mm
2
Power supply
216
V / F / Hz
(2+T)x2.5 3x0.75 220-240/1/50
Inspiration, Innovation, Evolution
R-410A
+
DOMESTIC HOT WATER
INSTALLATION EXAMPLE AMAZON III PRO 3 PIPES OUTDOOR UNIT
AMAZON INDUSTRIAL VRF
DOMESTIC HOT WATER RECOVERY KIT
KVBM2-DN3
KVBM2-DN3 DOMESTIC HOT WATER
INDOOR UNIT
217
INDUSTRIAL VRF RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
218
Inspiration, Innovation, Evolution
OUTDOOR UNITS
AMAZON INDUSTRIAL VRF
TECHNICAL SPECIFICATIONS
219
INDUSTRIAL VRF RANGE OUTDOOR UNITS
OUTDOOR UNITS RANGE 2 PIPES
POWER kW
8.0
10.5
12.0
14.0
16.0
18.0
KMF-105 DVN3
KMF-120 DVN2
KMF-140 DVN2
KMF-160 DVN2
KMF-120 DTN2
KMF-140 DTN2
KMF-160 DTN2
KMF-180 DTN2
25.2
26.0
28.0
33.5
K2UF-280 DN3
K2UF-335 DN3
K2UF-280 DN4 S
K2UF-335 DN4 S
MINI AMAZON II SINGLE-PHASE (Page 224)
FULL DC INVERTER
KMF-80 DVN3
THREE-PHASE (Page 226)
POWER kW
20.0
22.4
AMAZON UNITARIO FRONT AIR DISCHARGE (Page 228)
FULL DC INVERTER
KMF-200 DN2
KMF-224 DN2
TOP DISCHARGE DN3 (Page 230)
UNTIL END OF STOCK
NEW
(Page 232)
TOP DISCHARGE DN4 S
KMF-260 DN2
FULL DC INVERTER
AMAZON IV PRO
COMBINABLE UP TO 4 MODULES
(Page 236)
FULL DC INVERTER
K2F-252 DN4 S
AMAZON III W
K2F-280 DN4 S
COMBINABLE UP TO 3 MODULES
(Page 238) K2F-252 DN3W
3 PIPES
POWER kW
20.0
AMAZON III PRO FULL DC INVERTER
220
K2F-335 DN4 S
22.4
25.2
26.0
K2F-280 DN3W
K2F-335 DN3W
28.0
33.5
COMBINABLE UP TO 4 MODULES
(Page 242) K3F-252 DN3 S
K3F-280 DN3 S
K3F-335 DN3 S
Inspiration, Innovation, Evolution
22.4
25.2
26.0
28.0
33.5
40.0
50.0
56.0
61.5
67.0
73.0
K2UF-560 DN3
K2UF-615 DN3
K2UF-670 DN3
K2UF-560 DN4 S
K2UF-615 DN4 S
40.0
45.0
KMF-400 DN3
KMF-450 DN3
K2UF-400 DN3
K2UF-450 DN3
K2UF-400 DN4 S
K2UF-450 DN4 S K2UF-500 DN4 S
K2F-400 DN4 S
K2F-450 DN4 S
K2F-500 DN4 S
K2F-560 DN4 S
K2F-615 DN4 S
40.0
45.0
50.0
56.0
61.5
K3F-400 DN3 S
K3F-450 DN3 S
K2UF-670 DN4 S K2UF-730 DN4 S
45.0
78.5
K2UF-785 DN4 S
50.0
56.0
85.0
90.0
K2UF-850 DN4 S K2UF-900 DN4 S
AMAZON INDUSTRIAL VRF
20.0
67.0
73.0
78.5
85.0
90.0
221
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
VRF OUTDOOR UNITS
2 PIPES
AMAZON IV PRO KAYSUN continues to focus on its AMAZON IV PRO range. All the compressors and fans of this range are DC INVERTER, a feature that turns this new model into a FULL DC INVERTER. Furthermore, unlike previous ranges, these units are fitted with 2 additional modules, thereby allowing for more combinations. Now we have 8 modules from 8HP to 22HP, which are available to combine up to 88 HP (4 modules maximum). We would like to highlight this range's novel and dynamic design , unique on the market, which compared to previous models, allows for installing the units in smaller spaces according to their capacity. As is always the case, depending on the type of combination, the units of this new range allow us to connect up to 64 indoor units. However, some of the most outstanding features of previous models have been kept for this new range, such as: Delta-shaped heat exchangers that enhance subcooling and allow for longer installation distances self-addressing function, up to 150% simultaneity, silent ventilation and 40Pa available pressure in fans.
+
FULL DC INVERTER
AMAZON UNITARIO
NEW
222
AMAZON UNITARIO, the KAYSUN range of non-combinable units, has units with 28kW to 90 kW top discharge and up to 40Pa available pressure, and 5 front air discharge units from 20kW to 45kW. This INVERTER technology single solution of KAYSUN allows for combining up to 53 indoor units and a 200 metres maximum installation distance between the outdoor unit and the furthest indoor unit. This unit also provides a 150% simultaneity, highly efficient compressors and a silent ventilation system and a rotary electric box. This is a very thorough and competitive product.
MINI AMAZON II
AMAZON III W
The MINI AMAZON II generation with 2 ducts, DC Inverter compressor and fan motor keeps its 9 models. The design of fan´s blades and grille, as well as the DC Inverter technology used therein and in the “Twin Rotary“ compressor motor, provides the unit with outstanding energy efficiency and work range. KAYSUN seeks to provide versatility and total freedom, adding up to 9 indoor units to the combinations of the Mini AMAZON range and expanding the cooling distances up to 60 meters of actual overall length. Outdoor units automatically distribute the address to indoor units with no manual adjustment. In addition, 12, 14, 16 and 18 kW can be installed in 4 different positions, thereby making installation easier. Moreover, the XYE port in the outdoor unit's board allows for the connection of the centralised control panel of indoor unit directly to the outdoor unit.
The new AMAZON III W range of 2 water condensed pipes with DC INVERTER compressors stands out from the whole range because of its modular design, which supports combinations up to 36 HP through the combination of 3 basic modules of 8-1012 HP with which you can install up to a maximum of 59 indoor units. The structure of the new unit is much more compact and lightweight compared to the AMAZON air-condensed outdoor units. Thanks to its small size and the possibility of vertical installation (one outdoor on top of the other due to the lack of fans) allows it to be installed in very tight spaces. The lack of fans obviously reduces the sound pressure levels of outdoor units. Furthermore, due to the savings on consumption resulting from the lack of fans, energy efficiency notably increases if compared to the AMAZON air-condensed system, making it one of the strengths of the AMAZON III W.
MULTIPLE COMBINATIONS The AMAZON range offers a wide variety of installation possibilities from 9 types of indoor units with different ranges of cooling power, thereby allowing for the installation of 64 indoor units maximum, depending on the outdoor unit model or combinations thereof. This combination flexibility allows it to adapt to a wide variety of projects. One solution for every single need. Kaysun's VRF system allows for installations with 50 % to 150% simultaneity.
64
UP TO 64 INDOOR UNITS
OUTDOOR UNIT
INDOOR UNITS
Wall
Double flow console
Art flux 360º cassette
Floor with wraparound
Duct
High pressure duct
SYSTEMS WITH LONG DISTANCE COOLING PIPELINES AMAZON equipment allows for designing and arranging an entire cooling and heating system with greater flexibility. The planning and design difficulty inherent to air-conditioning projects in complex or large buildings are made simple thanks to the long pipes distance and height provided by our range of products.
223
AMAZON INDUSTRIAL VRF
Inspiration, Innovation, Evolution
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
MINI AMAZON II SINGLE-PHASE
2 PIPES
TECHNICAL SPECIFICATIONS KMF-80 DVN3 KMF-105 DVN3 KMF-120 DVN2 KMF-140 DVN2 KMF-160 DVN2
MODEL Cooling capacity
kW
7.2
9.0
12.3
14.0
15.5
Cooling capacity
Kcal/h
6880
8600
10578
12040
13330
Cooling input
kW
1.85
2.30
3.25
3.95
4.52
Heating Capacity
kW
8.4
10.5
13.2
15.4
17.00
Heating Capacity
Kcal/h
7224
9030
11352
13244
14620
kW
1.79
2.27
3.47
4.16
4.77
EER
3.90
3.92
3.78
3.54
3.43
COP Amount of connectable indoor units Power supply
4.02
3.97
3.80
3.70
3.56
4
5
6
6
7
220-240 / 1 / 50
220-240 / 1 / 50
220-240 / 1 / 50
220-240 / 1 / 50
220-240 / 1 / 50
Inverter compressor
1
1
1
1
1
Fans
1
1
2
2
2
mm (Inch)
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
mm (inches)
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø19.1 (3/4")
R-410A
R-410A
R-410A
R-410A
R-410A
gr
2800
2950
3300
3900
3900
Air flow
m3/h
3600
5100
6000
6000
6000
Width/Height/Depth
mm
990/966/336
990/966/336
900/1327/320
900/1327/320
900/1327/320
Net weight
Kg
62
72
95
95
100
Sound pressure
dB (A)
56
57
54
54
54
Power cord (under 20 metres)
mm2
(2+T)x2.5
(2+T)x4
(2+T)x4
(2+T)x6
(2+T)x6
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-15 to 43
-15 to 43
-15 to 43
-15 to 43
-15 to 43
Heating operation range
Cº
-15 to 27
-15 to 27
-15 to 27
-15 to 27
-15 to 27
Heating input
Liquid pipe diameter Gas pipe diameter
V / F / Hz
Refrigerant Refrigerant charging
BRANCH PIPES MODEL KCMI 112
224
(FRG100 + FRG200)
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
!
DC
INVERTER
OUTDOOR
GENERAL CHARACTERISTICS The Mini Amazon II system is ideal to meet the needs in small industrial environments. Its air condensed 2 pipe direct-expansion technology covers a range of cooling capacities from 8 up to 16 kW in single phase models. •
Depending on the model, single-phase units accept up to 7 indoor units.
•
It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
•
Since it is fitted with horizontal air discharge, it does not require much space for installation or maintenance.
•
The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.
•
Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.
•
It includes a self-addressing feature for indoor units.
•
The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.
•
The cooling pipeline of 12, 14 and 16kW models may be installed in 4 different positions, thereby facilitating their installation.
•
Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
+
ErP
8 / 10.5
+
AMAZON INDUSTRIAL VRF
12 / 14 / 16
DC INVERTER COMPRESSOR AND FAN
UP TO 7 INDOOR UNITS
225
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
MINI AMAZON II THREE-PHASE
2 PIPES
TECHNICAL SPECIFICATIONS KMF-120 DTN2
MODEL
KMF-140 DTN2
KMF-160 DTN2
KMF-180 DTN2
Cooling capacity
kW
12.3
14.0
15.5
17.5
Cooling capacity
Kcal/h
10578
12040
13330
15050
Cooling input
kW
3.25
4.08
4.52
5.60
Heating Capacity
kW
13.2
15.4
17.0
19.0
Heating Capacity
Kcal/h
11352
13244
14620
16340
kW
3.47
4.12
4.77
5
EER
3.78
3.54
3.43
3.30
COP
3.80
3.70
3.56
3.80
6
6
7
9
380-400 / 3 / 50
380-400 / 3 / 50
380-400 / 3 / 50
380-400 / 3 / 50
Inverter compressor
1
1
1
1
Fans
2
2
2
2
mm (Inch)
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
mm (inches)
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø19.1 (3/4")
Ø19.1 (3/4")
R-410A
R-410A
R-410A
R-410A
gr
3300
3900
3900
4500
Air flow
m3/h
6000
6000
6000
6800
Width/Height/Depth
mm
900/1327/320
900/1327/320
900/1327/320
900/1327/320
Net weight
Kg
95
95
102
107
Sound pressure
dB (A)
57
57
57
59
Power cord (under 20 metres)
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-15 to 43
-15 to 43
-15 to 43
-15 to 43
Heating operation range
Cº
-15 to 27
-15 to 27
-15 to 27
-15 to 27
Heating input
Amount of connectable indoor units Power supply
Liquid pipe diameter Gas pipe diameter
V / F / Hz
Refrigerant Refrigerant charging
BRANCH PIPES MODEL KCMI 112
226
(FRG100 + FRG200)
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
!
DC
INVERTER
OUTDOOR
GENERAL CHARACTERISTICS The Mini Amazon II system is ideal to meet the needs in small industrial environments. Its air condensed 2 pipe direct-expansion technology covers a range of cooling capacities from 12 up to 18 kW in three phase models. •
Depending on the model, three-phase units accept up to 9 indoor units.
•
It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
•
Since it is fitted with horizontal air discharge, it does not require much space for installation or maintenance.
•
The entire range works only with DC Inverter compressors and fans, which provides it with remarkable energy efficiency and low consumption and sound levels.
•
Compressor with highly-efficiency double eccentric Twin Rotary DC Inverter with environmentally friendly refrigerant R410A.
•
It includes a self-addressing feature for indoor units.
•
The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.
•
The cooling pipeline of 12, 14, 16 and 18 kW models may be installed in 4 different positions, thereby facilitating their installation.
•
Up to 70 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
+ +
AMAZON INDUSTRIAL VRF
12 / 14 / 16 / 18
DC INVERTER COMPRESSOR AND FAN
UP TO 12 INDOOR UNITS
227
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
AMAZON UNITARIO
FRONT AIR DISCHARGE
TECHNICAL SPECIFICATIONS KMF-200 DN2 KMF-224 DN2 KMF-260 DN2 KMF-400 DN3 KMF-450 DN3
MODEL Cooling capacity
kW
20.0
22.4
26.0
40.0
45.0
Cooling capacity
Kcal/h
17200
19264
22360
34400
38700
Cooling input power
kW
6.10
6.80
7.60
11.90
13.60
Heating capacity
kW
22.0
24.5
28.5
45.0
50.0
Heating capacity
Kcal/h
18920
21070
24510
38700
43000
kW
6.10
5.90
6.80
11.10
12.70
EER
3.28
3.29
3.42
3.35
3.32
COP
3.61
4.15
1.19
4.05
3.93
10
11
12
14
15
380-400 / 3 / 50
380-400 / 3 / 50
380-400 / 3 / 50
380-400 / 3 / 50
380-400 / 3 / 50
Inverter compressors
1
1
1
2
2
Fans
2
2
2
2
2
Heating input power
Amount of connectable indoor units Power supply
V / F / Hz
Liquid pipe diameter
mm (Inch)
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø12.7 (1/2")
Ø12.7 (1/2")
Gas pipe diameter
mm (Inch)
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø22.2 (7/8")
Ø22.2 (7/8")
Ø25.4 (1")
R-410A
R-410A
R-410A
R-410A
R-410A
gr
4800
6200
6200
9000
12000
Airflow
m3/h
10999
10494
10494
16575
16575
Width/Height/Depth
mm
1120/1558/400
1120/1558/400
1120/1558/400
1360/1650/540
1360/1650/540
Net weight
Kg
137
146
147
240
275
Sound pressure
dB (A)
59
59
60
62
62
Power cord (under 20 metres)
mm2
(4+T)x2.5
(4+T)x2.5
(4+T)x2.5
(4+T)x10
(4+T)x16
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-15 to 46
-15 to 46
-15 to 46
-5 to 48
-5 to 48
Heating operation range
Cº
-15 to 24
-15 to 24
-15 to 24
-15 to 24
-15 to 24
Refrigerant Refrigerant charging*
BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)
228
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
!
DC
INVERTER OUTDOOR
GENERAL CHARACTERISTICS The AMAZON UNITARIO SIDE AIR DISCHARGE range has non-combinable external VRF units between 20 kW and 45 kW. The big advantage of these units is the possibility to install higher power equipments in confined spaces. •
Depending on the model, they accept up to 15 indoor units.
•
•
It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
Night mode is included as an option in order to reduce the sound level of outdoor units.
•
It includes a self-addressing feature for indoor units.
•
Since it is fitted with front air discharge, it does not require much space for installation or maintenance.
•
The outdoor unit includes the XYE port to communicate with the centralised control panel of indoor units.
•
The entire range works only with Twin Rotary DC Inverter compressors and DC Inverter fans, which provides it with remarkable energy efficiency and low consumption and sound levels.
•
Up to 120 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
+ +
AMAZON INDUSTRIAL VRF
20 / 22 / 26 / 40 / 45
UP TO 15 INDOOR UNITS
INVERTER COMPRESSORS AND FANS
229
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
AMAZON UNITARIO
TOP DISCHARGE DN3
UNTIL END OF STOCK
TECHNICAL SPECIFICATIONS K2UF-280 DN3
MODEL
K2UF-335 DN3
K2UF-400 DN3
K2UF-450 DN3
K2UF-560 DN3
K2UF-615 DN3
K2UF-670 DN3
Capacity
HP
10
12
14
16
20
22
24
Cooling capacity
kW
28
33.5
40
45
56
61.5
67
Cooling capacity
Kcal/h
24080
28810
34400
38700
48160
52890
57620
Cooling input
kW
7.19
9.05
12.30
14.01
17.00
18.80
20.80
Heating Capacity
kW
32
37.5
45
50
63
69
75
Heating Capacity
Kcal/h
27090
32250
38700
43000
54180
59340
64500
kW
7.60
8.99
11.20
12.80
16.00
17.90
19.80
EER
3.89
3.70
3.25
3.21
3.30
3.27
3.22
COP
4.14
4.17
4.02
3.91
3.94
3.86
3.79
16
16
16
20
33
36
39
380 / 3 / 50
380 / 3 / 50
380 / 3 / 50
380 / 3 / 50
380 / 3 / 50
380 / 3 / 50
380 / 3 / 50
Inverter compressor
1
1
1
1
1
1
1
Fixed Scroll compressors
0
1
2
2
2
2
2
Fans
1
2
2
2
2
2
2
Heating input
Amount of connectable indoor units Power supply
V / F / Hz
Liquid pipe diameter
mm (Inch)
Ø12.7 (1/2")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø19.1 (3/4")
Gas pipe diameter
mm (Inch)
Ø25.4 (1")
Ø31.8 (1 1/4")
Ø31.8 (1 1/4")
Ø31.8 (1 1/4")
Ø31.8 (1 1/4")
Ø31.8 (1 1/4")
Ø31.8 (1 1/4")
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
gr
10000
12000
15000
15000
17000
18500
18500
m3/h
11,000
15,000
15,000
15,000
18,000
22,100
22,100
Pa
40
40
40
40
40
40
40
Refrigerant Refrigerant charging Air flow Static Pressure Width/Height/Depth
mm
Net weight
Kg
205
275
325
325
360
385
390
Sound pressure
dB (A)
58
58
60
60
62
63
63
Power cord (under 20 metres)
mm2
(4+T)*4
(4+T)*6
(4+T)*10
(4+T)*16
(4+T)*16
(4+T)*25
(4+T)*25
Communication wiring
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-5 to 48
-5 to 48
-5 to 48
-5 to 48
-5 to 48
-5 to 48
-5 to 48
Heating operation range
Cº
-15 to 24
-15 to 24
-15 to 24
-15 to 24
-20 to 27
-20 to 27
-20 to 27
BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)
230
960/1615/765 1250/1615/765 1250/1615/765 1250/1615/765 1390/1615/765 1585/1615/765 1585/1615/765
Inspiration, Innovation, Evolution
R-410A
!
GENERAL CHARACTERISTICS Direct-expansion system for 2 air-condensed pipes designed for 28 kW to 67 kW cooling power units. It is ideal for airconditioning large spaces that require the creation of atmospheres with different temperatures. Inverter fan.
Individual (non-combinable) outdoor units with capacity ranging from 10 to 24 hp (7 models). This system is able to combine between 16 and 39 indoor units.
•
Night mode is included as an option in order to reduce the sound level of outdoor units.
•
It admits a 50% to 150% simultaneity index of the outdoor unit's power.
•
Highly-efficiency scroll and fixed DC Inverter compressors with environmentally friendly R410A refrigerant.
•
Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC
•
Up to 175 metres of actual length for the pipes connecting the outdoor unit with the farthest indoor unit.
+ +
AMAZON INDUSTRIAL VRF
•
UP TO 39 INDOOR UNITS
NON-COMBINABLE SYSTEMS
231
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
AMAZON UNITARIO
TOP DISCHARGE DN4 S
NEW
TECHNICAL SPECIFICATIONS MODEL
K2UF-280 DN4 S
K2UF-335 DN4 S
K2UF-400 DN4 S
K2UF-450 DN4 S
Capacity
HP
10
12
14
16
Cooling capacity
kW
28
33.5
40
45
Cooling capacity
Kcal/h
24080
28810
34400
38700
Cooling input
kW
6.7
8.9
11.0
12.9
Heating Capacity
kW
28
33.5
40
45
Heating Capacity
Kcal/h
24080
28810
34400
38700
kW
5.5
7.6
9.3
10.7
EER
4.20
3.75
3.65
3.50
COP
5.10
4.40
4.30
4.20
16
20
23
26
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
Inverter compressor
1
1
1
1
Fans
1
1
1
1
Heating input
Amount of connectable indoor units Power supply
V / F / Hz
Liquid pipe diameter
mm (Inch)
ø12.7 (1/2")
ø15.9 (5/8")
ø15.9 (5/8")
ø15.9 (5/8")
Gas pipe diameter
mm (Inch)
ø25.4 (1")
ø28.6 (1 1/8")
ø31.8 (1 1/4")
ø31.8 (1 1/4")
R-410A
R-410A
R-410A
R-410A
gr
11000
11000
13000
13000
m3/h
11000
11000
13000
13000
Pa
60
60
60
60
Width/Height/Depth
mm
990/1635/790
990/1635/790
1340/1635/850
1340/1635/850
Net weight
Kg
227
227
277
277
Sound pressure
dB (A)
58
60
62
65
Power cord (under 20 metres)
mm2
(4+T)*4
(4+T)*6
(4+T)*10
(4+T)*16
Shielded communication wires
mm
3x0.75
3x0.75
3x0.75
3X0.75
Cooling operation range
Cº
-5 to 48
-5 to 48
-5 to 48
-5 to 48
Heating operation range
Cº
-23 to 24
-23 to 24
-23 to 24
-23 to 24
Refrigerant Refrigerant charging Air flow Static Pressure
BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)
232
2
Inspiration, Innovation, Evolution
DC
K2UF-500 DN4 S
MODEL
K2UF-560 DN4 S
K2UF-615 DN4 S
!
INVERTER
DC
INVERTER
OUTDOOR
K2UF-670 DN4 S
Capacity
HP
18
20
22
24
Cooling capacity
kW
50
56
61.5
67
Cooling capacity
Kcal/h
43000
48160
52890
57620
Cooling input
kW
14.7
16.0
20.2
21.6
Heating Capacity
kW
50
56
62
67
Heating Capacity
Kcal/h
43000
48160
52890
57620
kW
12.2
13.8
17.6
16.8
EER
3.40
3.50
3.05
3.10
COP
4.10
4.05
3.50
4.00
29
33
36
39
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
Inverter compressor
1
2
2
2
Fans
1
2
2
2
Heating input
Amount of connectable indoor units Power supply
V / F / Hz
Liquid pipe diameter
mm (Inch)
ø19.1 (3/4")
ø19.1 (3/4")
ø19.1 (3/4")
ø19.1 (3/4")
Gas pipe diameter
mm (Inch)
ø31.8 (1 1/4")
ø31.8 (1 1/4")
ø31.8 (1 1/4")
ø31.8 (1 1/4")
R-410A
R-410A
R-410A
R-410A
gr
13000
17000
17000
22000
m3/h
13000
17000
17000
25000
Pa
60
60
60
60
Width/Height/Depth
mm
1340/1635/850
1340/1635/825
1340/1635/825
1730/1830/850
Net weight
Kg
295
348
348
430
Sound pressure
dB (A)
65
66
66
67
Power cord (under 20 metres)
mm2
(4+T)*16
(4+T)*16
(4+T)*25
(4+T)*25
Shielded communication wires
mm
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-5 to 48
-5 to 48
-5 to 48
-5 to 48
Heating operation range
Cº
-23 to 24
-23 to 24
-23 to 24
-23 to 24
Refrigerant Refrigerant charging Air flow Static Pressure
2
BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)
233
AMAZON INDUSTRIAL VRF
R-410A
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
AMAZON UNITARIO TOP DISCHARGE DN4 S
NEW
TECHNICAL SPECIFICATIONS K2UF-730 DN4 S
MODEL
K2UF-785 DN4 S
K2UF-850 DN4 S K2UF-900 DN4 S
Capacity
HP
26
28
30
32
Cooling capacity
kW
73
78.5
85
90
Cooling capacity
Kcal/h
62780
67510
73100
77400
Cooling input
kW
21.6
24.9
28.3
32.1
Heating Capacity
kW
73.0
78.5
85.0
90.0
Heating Capacity
Kcal/h
62780
67510
73100
77400
kW
18.1
21.8
24.3
26.5
EER
3.40
3.15
3.00
2.80
COP
4.05
3.60
3.50
3.40
43
46
50
53
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
Inverter compressor
2
2
2
2
Fans
2
2
2
2
Heating input
Amount of connectable indoor units Power supply
V / F / Hz
Liquid pipe diameter
mm (Inch)
ø22.2 (7/8")
ø22.2 (7/8")
ø22.2 (7/8")
ø22.2 (7/8")
Gas pipe diameter
mm (Inch)
ø31.8 (1 1/4")
ø31.8 (1 1/4")
ø38.1 (1”-1/2)
ø38.1 (1”-1/2)
R-410A
R-410A
R-410A
R-410A
gr
22000
22000
25000
25000
m3/h
25000
25000
24000
24000
Pa
60
60
60
60
Width/Height/Depth
mm
1730/1830/850
1730/1830/850
1730/1830/850
1730/1830/850
Net weight
Kg
429
429
475
475
Sound pressure
dB (A)
68
68
68
68
Power cord (under 20 metres)
mm2
(4+T)*25
(4+T)*25
(4+T)*25
(4+T)*25
Shielded communication wires
mm
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-5 to 48
-5 to 48
-5 to 48
-5 to 48
Heating operation range
Cº
-23 to 24
-23 to 24
-23 to 24
-23 to 24
Refrigerant Refrigerant charging Air flow Static Pressure
BRANCH PIPES MODEL KCMI 112 (FRG100+FRG200) KCMI 212 (FRG100+FRG300) KCMI 312 (FRG200+FRG300) KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)
234
2
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
!
DC
INVERTER
OUTDOOR
GENERAL CHARACTERISTICS Direct-expansion system for 2 air-condensed pipes designed for 28 kW to 90 kW cooling power units. It is ideal for airconditioning large spaces that require the creation of atmospheres with different temperatures. •
Individual (non-combinable) outdoor units with capacity ranging from 10 to 32 hp. This system is able to combine between 16 and 53 indoor units.
•
It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
•
Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.
This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units even more efficient than previous models.
•
Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
•
They include a gas-to-gas heat exchanger. When is is in Cooling mode, it improves refrigerant subcooling; when it is in Heating mode, it improves units’ performance by steam injection.
Night mode is included as an option in order to reduce the sound level of outdoor units.
10 / 12
14 / 16 / 18 / 20 / 22
NEW
NEW
AMAZON INDUSTRIAL VRF
•
•
24 / 26 / 28 / 30 / 32
NEW
+
FULL DC INVERTER
+
NON-COMBINABLE SYSTEMS
235
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
AMAZON IV PRO
2 PIPES
TECHNICAL SPECIFICATIONS K2F-252 DN4 S
MODEL
K2F-280 DN4 S
K2F-335 DN4 S
K2F-400 DN4 S
K2F-450 DN4 S
K2F-500 DN4 S
K2F-560 DN4 S
K2F-615 DN4 S
Capacity
HP
8
10
12
14
16
18
20
22
Cooling capacity
kW
25.2
28
33.5
40
45
50
56
61.5
Cooling capacity
Kcal/h
21672
24080
28810
34400
38700
43000
48160
52890
Cooling input power
kW
6.25
7.49
8.91
11.66
13.64
14.71
16.47
19.84
Heating Capacity
kW
27
31.5
37.5
45
50
56
63
69
Heating Capacity
Kcal/h
23220
27090
32250
38700
43000
48160
54180
59340
kW
5.30
6.89
8.91
9.83
11.69
12.50
14.00
16.18
EER
4.03
3.74
3.76
3.43
3.30
3.40
3.40
3.10
COP
5.09
4.57
4.21
4.07
3.85
4.00
4.00
3.80
13
16
19
23
26
29
33
36
Heating input
Amount of connectable indoor units Power supply
V / F / Hz 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50 380-415/3/50
Inverter compressor
1
1
1
2
2
2
2
2
Fans
1
1
1
2
2
2
2
2
Oil balance pipe diameter
mm (Inch) Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Liquid pipe diameter
mm (Inch) Ø9.53 (3/8")
Ø9.53 (3/8")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Gas pipe diameter
mm (Inch) Ø22.2 (7/8")
Ø22.2 (7/8")
Ø25.4 (1")
Ø25.4 (1")
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
R-410A
gr
9000
9000
11000
13000
13000
13000
16000
16000
m3/h
12000
12000
12000
14000
14000
16000
16000
16000
Pa
40
40
40
40
40
40
40
40
Refrigerant Refrigerant charging Air flow Static Pressure
Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8") Ø28.6 (1 1/8")
Width/Height/Depth
mm
Net weight
Kg
219
219
237
297
297
305
340
dB (A)
58
59
60
62
62
63
63
Sound pressure
990/1635/790 990/1635/790 990/1635/790 1340/1635/7901340/1635/7901340/1635/7901340/1635/7901340/1635/790 340 63
33
Power cord (under 20 metres)
mm2
(4+T)x2.5
(4+T)x4
(4+T)x6
(4+T)x10
(4+T)x16
(4+T)x16
(4+T)x16
(4+T)x16
Communication wiring
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
Heating operation range
Cº
BRANCH PIPES MODEL
From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -5 to 48 From -20 to 24
From -20 to 24
From -20 to 24
From -20 to 24
MODEL KCME 12
KCMI 212 (FRG100+FRG300)
KCME 13
KCMI 312 (FRG200+FRG300)
KCME 14
KCMI 512 (FRG300+FRG500)
236
From -20 to 24
From -20 to 24
From -20 to 24
OUTDOOR MODULES T-TYPE BRANCH PIPES
KCMI 112 (FRG100+FRG200)
KCMI 412 (FRG200+FRG400)
From -20 to 24
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
!
DC
INVERTER
OUTDOOR
GENERAL CHARACTERISTICS Direct-expansion system for 2 air-condensed pipes designed for 25.2 kW to 246 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments.
•
This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units even more efficient than previous models. The new design of the fan's blades and protection grille reduces sound levels and increase airflow. Modular design with the option of combining the 8 individual modules (8-1012-14-16-18-20 and 22 hp) up to 88 hp (4 modules maximum).
•
The 12, 20 and 22 HP models are smaller if compared to previous versions because we use an extra 21% of heat exchanger's surface.
•
Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.
C
ON
YOUR SE
TI
CHO O
8 / 10 / 12
OMBI NA
•
They allow for combinations containing up to 64 indoor units.
•
It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
•
Fitted with a top air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.
•
Delta-shaped heat exchanger; it enhances subcooling values up to 12ºC and improves the exchanger's efficiency.
•
Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
AMAZON INDUSTRIAL VRF
•
14 / 16 / 18 / 20 / 22
+ +
FULL DC INVERTER
UP TO 64 INDOOR UNITS
237
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 2 PIPES
AMAZON III W
2 PIPES
TECHNICAL SPECIFICATIONS K2F-252 DN3W
MODEL
K2F-280 DN3W
K2F-335 DN3W
Capacity
HP
8
10
12
Cooling capacity
kW
25.2
28
33.5
Cooling capacity
Kcal/h
21672
24080
28810
Cooling input
kW
4.8
6.1
8
Heating Capacity
kW
27
31.5
37.5
Heating Capacity
Kcal/h
23220
27090
32250
kW
4.5
5.8
7.8
EER
5.25
4.59
4.19
COP
6.07
5.40
4.81
13
16
19
380-415/3/50
380-415/3/50
380-415/3/50
Inverter compressor
1
1
1
Heat exchanger type
Pipe in pipe
Pipe in pipe
Pipe in pipe
Heating input
Amount of connectable indoor units Power supply
V / F / Hz
Water flow rate
m3/h
5.4
6.0
7.2
Load loss
kPa
35
40
48
Water pipe max. pressure
Mpa
1.98
1.98
1.98
Water inlet pipe diameter
DN32
DN32
DN32
Water outlet pipe diameter
DN32
DN32
DN32
Oil balance pipe diameter
mm (Inch)
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Liquid pipe diameter
mm (Inch)
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø15.9 (5/8")
Gas pipe diameter
mm (Inch)
Ø25.4 (1")
Ø25.4 (1")
Ø31.8 (1 1/4")
R-410A
R-410A
R-410A
Refrigerant Refrigerant charging
gr
2000
2000
2000
Width/Height/Depth
mm
780/1000/550
780/1000/550
780/1000/550
Net weight
Kg
146
146
146
Sound pressure
dB (A)
51.0
52.0
52.0
Power cord (under 20 metres)
mm2
(4+T)x2.5
(4+T)x4
(4+T)x6
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
Water inlet temperature range
Cº
From 7 to 45
From 7 to 45
From 7 to 45
BRANCH PIPES MODEL
OUTDOOR MODULES T-TYPE BRANCHES MODEL
KCMI 112 (FRG100+FRG200)
KCME 12
KCMI 212 (FRG100+FRG300)
KCME 13
KCMI 312 (FRG200+FRG300)
KCME 14
KCMI 412 (FRG200+FRG400) KCMI 512 (FRG300+FRG500)
238
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
GENERAL CHARACTERISTICS Direct-expansion system for 2 air condensed pipes designed for 25.2 kW to 100.5 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments. • It admits a 50 % to 150 % simultaneity index of the outdoor unit's power. • Because of the lack of fans, this system is more efficient that air-condensed systems and provides low consumption and sound levels. • Compared to previous air-condensed outdoor units, this outdoor unit is more compact and lightweight and provides a significant reduction in weight, area and volume. • Up to 150 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
C
ON
AMAZON INDUSTRIAL VRF
YOUR SE
TI
CHO O
• This range is equipped with high capacity Scroll DC Inverter compressors and environmentally friendly R410A refrigerant. These features make these units a very efficient product. • Modular design with the option of combining the 3 individual modules (8-10-12 hp) up to 36 hp (3 modules maximum). • Shell and tube heat exchanger and highly-efficient cross airflow. • Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves. • They allow for combinations containing up to 59 indoor units.
OMBI NA
CONDENSED BY WATER
+
UP TO 59 INDOOR UNITS
239
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 3 PIPES
VRF OUTDOOR UNITS
3 PIPES
3 DUCTS AMAZON III PRO • • • • • •
5 available modules from 25,2 kW to 45 kW Up to 4 combinable modules (180 kW) Up to 64 combinable indoor units Optimized fan design Better energy efficiency Working range between -5ºC and 48ºC in cooling mode and between -20ºC and 24ºC in heating mode.
• New ventilation system One fan with 3 blades and a second fan with 4 blades
• DOUBLE SUBCOOLING: Condenser interchanger in delta form • Subcooling takes place in exchanger.
1000 m LONG DISTANCE COOLING PIPES
CONTINUOUS HEATING during defrosting • AMAZON III PRO Full DC Inverter
FULL DC INVERTER
• Compact and lightweight • Easy transport and installation. • Rotating electrical box
CONTINUOUS HEATING DURING DEFROSTING Thanks to the double condenser, the first performs the defrosting process first, then the second, thus maintaining the indoor units in heating mode during the entire process. At the same time, the unit can work with a single condenser to compensate for the highest load of the system both in cold and heat, which represents substantial energy savings and remarkable energy efficiency in the cooling circuit.
DOUBLE SUBCOOLING AMAZON III PRO 3 pipes has a dual system of liquid subcooling that increases the system's energy efficiency. The delta-shaped heat exchanger shouldreduce its load loss by increasing liquid proportion and therefore, arranging longer pipeline lengths. Thanks to this subcooling technology, liquid temperatures at the condenser outlet may reach up to 37.1ºC.
Subcooling 49 - 43 = 6ºC
OPTIMISED FAN DESIGN
Subcooling 49 - 37.1 = 12ºC
The second stage of the subcooling process is carried out in each series inverter box since, thanks to a small liquid bypass pipe, subcooling temperature may reach 22.1ºC.
New ventilation system: one fan fitted with 3 blades and a second fan fitted with 4 blades. This reduces the effect of acoustic resonance that directly affects the noise level of the outdoor unit. MAINTENANCE
Subcooling pipe
Thanks to the rotary electrical box, the cooling circuit can be accessed more easily for maintenance and installation. At the same time, the electrical box is fitted with an inspection window at the electronic board to check any malfunction without disassembling it.
240
Inspiration, Innovation, Evolution
INVERTER BOX SIMULTANEITY BETWEEN HEAT AND COLD
INVERTER BOX MULTIGROUP Available in versions of 2, 4 and 6 outputs, they support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model (see table in the AMAZON III PRO Inverter Box section). Each output can work in a different mode.
241
AMAZON INDUSTRIAL VRF
Thanks to the series inverter boxes, the system is capable of providing heat and cold simultaneously, generating heat recovery in the system and therefore overall energy savings.
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 3 PIPES
AMAZON III PRO
3 PIPES
TECHNICAL SPECIFICATIONS K3F-252 DN3S K3F-280 DN3S K3F-335 DN3S K3F-400 DN3S K3F-450 DN3S
MODEL Capacity
HP
8
10
12
14
16
Cooling capacity
kW
25.2
28
33.5
40
45
Cooling capacity
Kcal/h
21,672
24,080
28,810
34,400
38,700
Cooling input
kW
5.73
6.67
8.07
11.3
13.24
Heating Capacity
kW
27
31.5
37.5
45
50
Heating Capacity
Kcal/h
23220
27090
32250
38700
43000
kW
Heating input
6.00
7.33
8.72
11.19
12.79
EER
4.40
4.20
4.15
3.54
3.40
COP
4.50
4.30
4.30
4.02
3.91
Amount of connectable indoor units Power supply
V / F / Hz
Inverter compressor Fans
13
16
20
23
26
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
380-415 / 3 / 50
1
1
1
2
2
2
2
2
2
2
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø6.4 (1/4")
Ø12.7 (1/2")
Ø12.7 (1/2")
Ø15.9 (5/8")
Ø15.9 (5/8")
Oil balance pipe diameter
mm (Inch)
Ø6.4 (1/4")
Liquid pipe diameter
mm (Inch)
Ø9.53 (3/8")
High presure gas pipe diameter
mm (Inch)
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø22.2 (7/8")
Ø22.2 (7/8")
Low pressure gas pipe diameter
mm (Inch)
Ø22.2 (7/8")
Ø22.2 (7/8")
Ø25.4 (1")
Ø28.6 (1 1/8")
Ø28.6 (1 1/8")
Oil balance pipe diameter high-pressure gas
mm (Inch)
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø19.1 (3/4")
Ø19.1 (3/4")
R-410A
R-410A
R-410A
R-410A
R-410A
gr
10000
10000
10000
13000
13000
m3/h
12000
12000
13000
15000
15000
Static Pressure
Pa
40
40
40
40
40
Width/Height/Depth
mm
1250/1615/765
1250/1615/765
1250/1615/765
1250/1615/765
1250/1615/765
Net weight
Kg
255
255
255
303
303
Sound pressure
dB (A)
57
57
58
60
60
Power cord (under 20 metres)
mm2
(4+T)x2.5
(4+T)x4
(4+T)x6
(4+T)x10
(4+T)x16
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
Cooling operation range
Cº
-5 to 48
-5 to 48
-5 to 48
-5 to 48
-5 to 48
Heating operation range
Cº
-20 to 24
-20 to 24
-20 to 24
-20 to 24
-20 to 24
Refrigerant Refrigerant charging Air flow
BRANCH PIPES - 3 PIPES MODEL KCMI 113 (FRG100+FRG200+FRG200) KCMI 213 (FRG100+FRG200+FRG300) KCMI 313 (FRG200+FRG300+FRG300)
BRANCH PIPES - 2 PIPES MODEL KCMI 112 (FRG100+FRG200)
OUTDOOR MODULES T-TYPE BRANCHES
KCMI 413 (FRG200+FRG300+FRG400)
MODEL
KCMI 513 (FRG300+FRG400+FRG500)
KCMER 32 KCMER 33 KCMER 34
242
Inspiration, Innovation, Evolution
DC R-410A
INVERTER
!
DC
INVERTER
GENERAL CHARACTERISTICS Direct-expansion system for 3 air-condensed pipes designed for 25.2 kW to 180 kW cooling power units. Ideal for meeting the needs in medium and large industrial environments.
•
Modular design with the option of combining the 5 individual modules (8-10-12-14 and 16 HP) up to 64 hp (4 modules maximum).
•
Standard automatic redundancy between modules. It balances and extends the working life of the compressors of each module, whether of the Master unit or any of the Slaves.
•
They allow for combinations containing up to 64 indoor units.
•
It admits a 50 % to 150 % simultaneity index of the outdoor unit's power.
ON TI
OMBIN
A
C
YOUR SE
•
Fitted with a vertical air discharge system, this range is able to make air circulates through the condensation system thanks to the 40 Pa available pressure supplied by its DC Inverter fan.
•
Cooling system with double liquid subcooling; the first system performs the subcooling process thanks to the delta-shaped heat exchanger and the second system carries out the subcooling process in each series inverter box, thereby reaching up to 22.1 ºC and very high levels of energy efficiency.
•
Up to 200 metres equivalent length between the outdoor unit and the farthest indoor unit (for further information, see the cooling distances tables).
64
INDOOR UNITS
DC
FULL DC INVERTER
dB
A NEW DESIGN WITH NOISE LEVELS REDUCTION THAT WHICH INCREASES AIRFLOW
INVERTER
AMAZON INDUSTRIAL VRF
High capacity Scroll DC Inverter compressors and ecological R410A refrigerant.
CHOO
•
243
INDUSTRIAL VRF RANGE OUTDOOR UNITS - 3 PIPES
CHANGEOVER BOXES
3 PIPES
TECHNICAL SPECIFICATIONS KVBM2 DN3
MODEL
KVBM4 DN3
KVBM6 DN3
KVBH2 DN3
KVBH4 DN3
Cooling capacity
kW
Up to 28
Up to 45
Up to 45
Up to 28
Up to 56
Cooling power per output
kW
Up to 16
Up to 16
Up to 16
Up to 16
Up to 16
Max. amount of connectable indoor units
8
16
24
1
1
Maximum amount of indoor units per output
4
4
4
-
-
Width/Height/Depth
mm
630/225/600
960/225/600
960/225/600
630/225/600
960/225/600
Net weight
Kg
19.5
31
35
19.5
31
Inlet liquid pipe Liquid
mm (Inch)
Ø12.7 (1/2")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø12.7 (1/2")
Ø15.9 (5/8")
Inlet liquid pipe high-pressure gas
mm (Inch)
Ø19.1 (3/4")
Ø22.2 (7/8")
Ø22.2 (7/8")
Ø19.1 (3/4")
Ø22.2 (7/8")
Inlet liquid pipe high-pressure gas
mm (Inch)
Ø25.4 (1")
Ø31.8 (1 1/4")
Ø31.8 (1 1/4")
Ø25.4 (1")
Ø31.8 (1 1/4")
Inlet liquid pipe Internal liquid per output
mm (Inch)
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Ø9.53 (3/8")
Inlet liquid pipe Internal gas per output
mm (Inch)
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Ø15.9 (5/8")
Shielded communication wires
mm2
3x0.75
3x0.75
3x0.75
3x0.75
3x0.75
Power wiring (under 20 metres)
mm2
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
(2+T)x2.5
V / F / Hz
220-240 / 1 / 50
220-240 / 1 / 50
220-240 / 1 / 50
220-240 / 1 / 50
220-240 / 1 / 50
Power supply voltage
CHANGEOVER BOX MULTI
244
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS Thanks to the series Changeover, the system is capable of providing heat and cold simultaneously, generating heat recovery in the system and therefore overall energy savings. KVBM boxes available in versions of 2.4 and 6 outputs, they support a maximum of 45 kW of capacity and up to 24 indoor units depending on the model. KVBH boxes are designed for high-capacity ducts units (for further information, please see attached table).
CHANGEOVER BOX MULTIGROUP PER OUTPUT MODEL
NUMBER OF OUTPUTS
Max UI Capacity (KW)
PER CHANGEOVER BOX
Max UI Capacity (KW)
Max UI Capacity (KW)
Max UI Capacity (KW)
KVBM2 DN3
2
16
4
28
8
KVBM4 DN3
4
16
4
45
16
6
16
4
45
24
2
-
-
28
1
KVBH4 DN3
4
-
-
56
1
AMAZON INDUSTRIAL VRF
KVBM6 DN3 KVBH2 DN3
COOLING
HEATING
Â
245
INDUSTRIAL VRF RANGE MEASURING
MEASURING
DISTANCES AND HEIGHT DIFFERENCES MINI AMAZON II DIMENSIONS
2 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A
TOTAL LENGTH OF LIQUID PIPE <45 M CAPACITY OF OUTDOOR UNIT
PIPE DIAMETER MM (INCHES) GAS
LIQUID
From 8 kW to 14 kW
Ø15.9 (5/8”)
Ø9.5 (3/8”)
From 16 kW to 18 kW
Ø19.1 (3/4”)
Ø9.5 (3/8”)
TOTAL LENGTH OF LIQUID PIPE ≥45 M PIPE DIAMETER MM (INCHES)
BRANCH
BRANCH
GAS
LIQUID
KCMI 112
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 112
KCMI 112
Ø22.2 (7/8”)
Ø12.7 (1/2”)
KCMI 212
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (X100W)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES)
BRANCH
GAS
LIQUID
Ø19.1 (3/4”)
Ø12.7 (1/2”)
BRANCH
GAS
LIQUID
A<160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
KCMI 112
160≤A<230
Ø19.1 (3/4”)
Ø9.5 (3/8”)
KCMI 112
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 212
230≤A<330
Ø22.2 (7/8”)
Ø9.5 (3/8”)
KCMI 212
Ø22.2 (7/8”)
Ø12.7 (1/2”)
KCMI 212
Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.
KCMI 112
A - Capacity of indoor unit/units
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C INDOOR UNIT TOTAL CAPACITY (X100W)
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*
PIPE DIAMETER MM (INCHES)
PIPE DIAMETER MM (INCHES)
GAS
LIQUID
GAS
LIQUID
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
Ø19.1 (3/4”)
Ø12.7 (1/2”)
A - Capacity of indoor unit/units
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d.
N1
Important:
a
Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
246
e f
N6 N5
Inspiration, Innovation, Evolution
AMAZON UNITARIO FRONT AIR DISCHARGE
2 DUCTS
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <45 M CAPACITY OF OUTDOOR UNIT
PIPE DIAMETER MM (INCHES) GAS
LIQUID
From 20 kW to 22.4 kW
Ø19.1 (3/4”)
Ø9.5 (3/8”)
26 kW
Ø22.2 (7/8")
Ø9.5 (3/8”)
40 kW
Ø25.4 (1")
Ø12.7 (1/2”)
45 kW
Ø25.4 (1")
Ø12.7 (1/2”)
TOTAL LENGTH OF LIQUID PIPE ≥45 M PIPE DIAMETER MM (INCHES)
BRANCH
BRANCH
GAS
LIQUID
KCMI 112
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 212
Ø25.4 (1")
Ø12.7 (1/2”)
KCMI 312
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
KCMI 212
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective branches (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (X100W)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES) GAS
LIQUID
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤20 M PIPE DIAMETER MM (INCHES)
BRANCH
GAS
LIQUID
BRANCH
A<166
Ø15.9 (5/8”)
Ø9.5 (3/8”)
KCMI 112
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 112
166≤A<230
Ø19.1 (3/4”)
Ø9.5 (3/8”)
KCMI 112
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 212
230≤A<330
Ø22.2 (7/8")
Ø9.5 (3/8”)
KCMI 212
Ø25.4 (1")
Ø12.7 (1/2”)
KCMI 312
330≤A<460
Ø25.4 (1”)
Ø12.7 (1/2”)
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
460≤A<660
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5
A - Capacity of indoor unit/units
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) INDOOR UNIT TOTAL CAPACITY (X100W)
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*
PIPE DIAMETER MM (INCHES)
PIPE DIAMETER MM (INCHES)
GAS
LIQUID
GAS
LIQUID
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
Ø19.1 (3/4”)
Ø12.7 (1/2”)
200
Ø19.1 (3/4”)
Ø9.5 (3/8”)
Ø22.2 (7/8”)
Ø12.7 (1/2”)
250
Ø22.2 (7/8”)
Ø9.5 (3/8”)
Ø25.4 (1”)
Ø12.7 (1/2”)
280
Ø22.2 (7/8”)
Ø9.5 (3/8”)
Ø25.4 (1”)
Ø12.7 (1/2”)
400
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
450
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
AMAZON INDUSTRIAL VRF
TABLE C
A - Capacity of indoor unit/units
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d N1
Important:
a
Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
e f
N6 N5
247
INDUSTRIAL VRF RANGE MEASURING
AMAZON UNITARIO TOP AIR DISCHARGE DN3 (28-45 kW)
2 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M CAPACITY OF OUTDOOR UNIT
PIPE DIAMETER MM (INCHES)
TOTAL LENGTH OF LIQUID PIPE ≥90 M PIPE DIAMETER MM (INCHES)
BRANCH
GAS
BRANCH
GAS
LIQUID
LIQUID
28 kW
Ø25.4 (1")
Ø12.7 (1/2”)
KCMI 312
Ø25.4 (1")
Ø12.7 (1/2”)
KCMI 312
From 33.5 to 45 kW
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)
PIPE DIAMETER MM (INCHES) GAS
BRANCH
LIQUID
A<166
Ø19.1 (3/4”)
Ø9.5 (3/8”)
KCMI 112
166≤A<230
Ø22.2 (7/8”)
Ø9.5 (3/8”)
KCMI 212 KCMI 212
230≤A<330
Ø22.2 (7/8”)
Ø12.7 (1/2”)
330≤A<460
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
460≤A<660
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
A - Indoor units capacity
Note: Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M
INDOOR UNIT TOTAL CAPACITY (x100W)
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*
PIPE DIAMETER MM (INCHES)
PIPE DIAMETER MM (INCHES)
GAS
LIQUID
GAS
LIQUID
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
Ø19.1 (3/4”)
Ø12.7 (1/2”)
200
Ø19.1 (3/4”)
Ø9.5 (3/8”)
Ø22.2 (7/8”)
Ø12.7 (1/2”)
250
Ø22.2 (7/8”)
Ø9.5 (3/8”)
Ø25.4 (1”)
Ø12.7 (1/2”)
280
Ø22.2 (7/8”)
Ø9.5 (3/8”)
Ø25.4 (1”)
Ø12.7 (1/2”)
400
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
450
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
A - Capacity of indoor unit/units
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d
N1
Important:
a
Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
248
e f
N6 N5
Inspiration, Innovation, Evolution
AMAZON UNITARIO TOP AIR DISCHARGE DN3 (56-67 kW)
2 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M CAPACITY OF OUTDOOR UNIT
PIPE DIAMETER MM (INCHES) GAS
TOTAL LENGTH OF LIQUID PIPE ≥90 M PIPE DIAMETER MM (INCHES)
BRANCH
LIQUID
GAS
BRANCH
LIQUID
From 56 to 61.5 kW
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
67 kW
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M PIPE DIAMETER MM (INCHES) GAS
LIQUID
A<166
Ø15.9 (5/8”)
Ø9.5 (3/8”)
166≤A<230
Ø19.1 (3/4”)
Ø9.5 (3/8”)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M PIPE DIAMETER MM (INCHES)
BRANCH
BRANCH
GAS
LIQUID
KCMI 112
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 112
KCMI 112
Ø22.2 (7/8”)
Ø12.7 (1/2”)
KCMI 212
230≤A<330
Ø22.2 (7/8”)
Ø9.5 (3/8”)
KCMI 212
Ø25.4 (1”)
Ø12.7 (1/2”)
KCMI 312
330≤A<460
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
KCMI 412
460≤A<660
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
660≤A<920
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
920≤A<1350
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5
A - Capacity of indoor unit/units
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) INDOOR UNIT TOTAL CAPACITY (X100W)
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT ≤10 M
DISTANCE BETWEEN DRIFTER AND INDOOR UNIT >10 M*
PIPE DIAMETER MM (INCHES)
PIPE DIAMETER MM (INCHES)
GAS
LIQUID
GAS
LIQUID
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
Ø19.1 (3/4”)
Ø12.7 (1/2”)
200
Ø19.1 (3/4”)
Ø9.5 (3/8”)
Ø22.2 (7/8”)
Ø12.7 (1/2”)
250
Ø22.2 (7/8”)
Ø9.5 (3/8”)
Ø25.4 (1”)
Ø12.7 (1/2”)
280
Ø22.2 (7/8”)
Ø9.5 (3/8”)
Ø25.4 (1”)
Ø12.7 (1/2”)
400
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
450
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
560
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
AMAZON INDUSTRIAL VRF
TABLE C
A - Capacity of indoor unit/units
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B. N1
Important:
a
Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
e f
N6 N5
249
INDUSTRIAL VRF RANGE MEASURING
AMAZON UNITARIO TOP AIR DISCHARGE DN4 S
2 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M
CAPACITY OF OUTDOOR UNIT
TOTAL LENGTH OF LIQUID PIPE ≥90 M
PIPE DIAMETER MM (INCHES) GAS
PIPE DIAMETER MM (INCHES)
BRANCH
LIQUID
GAS
BRANCH
LIQUID
28 kW
Ø22.2 (7/8")
Ø9.5 (3/8”)
KCMI 212
Ø25.4 (1")
Ø12.7 (1/2”)
33,5 to 40 kW
Ø25.4 (1")
Ø12.7 (1/2”)
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312 KCMI 312
45 kW
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
KCMI 412
50 to 67 kW
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
73 to 90kW
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 412
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M
CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)
PIPE DIAMETER MM (INCHES) GAS
LIQUID
A<168
Ø15.9 (5/8”)
Ø9.5 (3/8”)
168≤A<224
Ø19.1 (3/4”)
Ø9.5 (3/8”)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M PIPE DIAMETER MM (INCHES)
BRANCH
BRANCH
GAS
LIQUID
KCMI 112
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 112
KCMI 112
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 212 KCMI 312
224≤A<330
Ø22.2 (7/8")
Ø9.5 (3/8”)
KCMI 212
Ø25.4 (1")
Ø12.7 (1/2”)
330≤A<470
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
KCMI 312
470≤A<710
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
710≤A<1040
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 412
1040≤A<1540
Ø41.3 (1”-5/8)
Ø19.1 (3/4”)
KCMI 412
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 412
A - Indoor units capacity
Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C DISTANCE BETWEEN BRANCH AND INDOOR UNIT ≤10 M PIPE DIAMETER MM (INCHES)
INDOOR UNIT TOTAL CAPACITY (x100W)
DISTANCE BETWEEN BRANCH AND INDOOR UNIT >10 M* PIPE DIAMETER MM (INCHES)
GAS
LIQUID
GAS
LIQUID
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
Ø19.1 (3/4”)
Ø12.7 (1/2”)
200
Ø19.1 (3/4”)
Ø9.5 (3/8”)
Ø22.2 (7/8")
Ø12.7 (1/2”)
250
Ø22.2 (7/8")
Ø9.5 (3/8”)
Ø25.4 (1")
Ø12.7 (1/2”)
280
Ø22.2 (7/8")
Ø9.5 (3/8”)
Ø25.4 (1")
Ø12.7 (1/2”)
400
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
450
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
560
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
A - Capacity of indoor unit/units
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B. N1
Important:
a
Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
250
e f
N6 N5
Inspiration, Innovation, Evolution
AMAZON III W
2 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M PIPE DIAMETER MM (INCHES) GAS LIQUID 25.2 kW Ø22.2 (7/8") Ø9.5 (3/8”) 28 kW Ø22.2 (7/8") Ø9.5 (3/8”) 33.5 kW Ø25.4 (1”) Ø12.7 (1/2”) 45 kW Ø28.6 (1”-1/8) Ø12.7 (1/2”) From 50 to 61.5 kW Ø28.6 (1”-1/8) Ø15.9 (5/8”) 67 kW Ø28.6 (1”-1/8) Ø15.9 (5/8”) From 73 to 95 kW Ø34.9 (1”-3/8) Ø19.1 (3/4”) 100 kW Ø41.3 (1”-5/8) Ø19.1 (3/4”) Note: To select the main pipe, use the greater diameter between A and B. CAPACITY OF OUTDOOR UNIT
TOTAL LENGTH OF LIQUID PIPE ≥90 M PIPE DIAMETER MM (INCHES) GAS LIQUID Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1") Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø15.9 (5/8”) Ø34.9 (1”-3/8) Ø15.9 (5/8”) Ø34.9 (1”-3/8) Ø19.1 (3/4”) Ø34.9 (1”-3/8) Ø19.1 (3/4”) Ø41.3 (1”-5/8) Ø22.2 (7/8”) Ø41.3 (1”-5/8) Ø22.2 (7/8”)
BRANCH KCMI 212 KCMI 212 KCMI 312 KCMI 312 KCMI 312 KCMI 312 KCMI 412 KCMI 412
BRANCH KCMI 212 KCMI 312 KCMI 312 KCMI 312 KCMI 412 KCMI 412 KCMI 412 KCMI 412
2 Selection of main and middle pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C) TABLE B CAPACITY OF UNITS CONECTED TO DRIFTER OR OUTDOOR UNIT (x100W)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M
PIPE DIAMETER MM (INCHES) BRANCH GAS LIQUID A<166 Ø15.9 (5/8”) Ø9.5 (3/8”) KCMI 112 166≤A<230 Ø19.1 (3/4”) Ø9.5 (3/8”) KCMI 112 230≤A<330 Ø22.2 (7/8") Ø9.5 (3/8”) KCMI 212 330≤A<460 Ø28.6 (1”-1/8) Ø12.7 (1/2”) KCMI 312 460≤A<660 Ø28.6 (1”-1/8) Ø15.9 (5/8”) KCMI 312 660≤A<920 Ø34.9 (1”-3/8) Ø19.1 (3/4”) KCMI 412 920≤A<1350 Ø41.3 (1”-5/8) Ø19.1 (3/4”) KCMI 412 Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L3>=L4 or L5.
PIPE DIAMETER MM (INCHES) GAS LIQUID Ø19.1 (3/4”) Ø12.7 (1/2”) Ø22.2 (7/8") Ø12.7 (1/2”) Ø25.4 (1") Ø12.7 (1/2”) Ø34.9 (1”-3/8) Ø15.9 (5/8”) Ø34.9 (1”-3/8) Ø19.1 (3/4”) Ø41.3 (1”-5/8) Ø22.2 (7/8") Ø41.3 (1”-5/8) Ø22.2 (7/8") L1>=L2 and
BRANCH KCMI 112 KCMI 212 KCMI 312 KCMI 412 KCMI 412 KCMI 412 KCMI 412
A - Indoor units capacity
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C
A≤45 56≤A≤160 200 250 280 400 450 560
DISTANCE BETWEEN BRANCH AND INDOOR UNIT ≤10 M PIPE DIAMETER MM (INCHES) GAS LIQUID Ø12.7 (1/2”) Ø6.4 (1/4”) Ø15.9 (5/8”) Ø9.5 (3/8”) Ø19.1 (3/4”) Ø9.5 (3/8”) Ø22.2 (7/8”) Ø9.5 (3/8”) Ø22.2 (7/8”) Ø9.5 (3/8”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø15.9 (5/8”)
DISTANCE BETWEEN BRANCH AND INDOOR UNIT >10 M* PIPE DIAMETER MM (INCHES) GAS LIQUID Ø15.9 (5/8”) Ø9.5 (3/8”) Ø19.1 (3/4”) Ø12.7 (1/2”) Ø22.2 (7/8”) Ø12.7 (1/2”) Ø25.4 (1”) Ø12.7 (1/2”) Ø25.4 (1”) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø12.7 (1/2”) Ø28.6 (1”-1/8) Ø15.9 (5/8”)
AMAZON INDUSTRIAL VRF
INDOOR UNIT TOTAL CAPACITY (x100W)
A - Capacity of indoor unit/units
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B.
4 Selection of drifters (L,M) and pipes (G1,g1,g2,g3) of outdoor unit when there is more than one outdoor module. TABLE D NUMBER OF ONLINE OUTDOOR UNITS
BRANCH MODEL
PIPES
2 (L) 3 (L and M)
KCME 12 KCME 13
G1
PIPE DIAMETER MM (INCHES) GAS LIQUID
OUTDOOR UNIT MODULES CAPACITY
g1,g2 and g3
Not required All possibilities Ø41.3 (1”-5/8) From 25.2 to 28 kW Ø25.4 (1”) 33.5 kW Ø28.6 (1”-1/8)
Ø19.1 (3/4”) Ø12.7 (1/2”) Ø15.9 (5/8”)
N1 a
Important: Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
e f
N6 N5
251
INDUSTRIAL VRF RANGE MEASURING
AMAZON IV PRO
2 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M
CAPACITY OF OUTDOOR UNIT
PIPE DIAMETER MM (INCHES) GAS
LIQUID
25.2 kW
Ø22.2 (7/8")
Ø9.5 (3/8”)
28 kW
Ø22.2 (7/8")
Ø9.5 (3/8”)
From 33.5 to 40 kW
Ø25.4 (1")
TOTAL LENGTH OF LIQUID PIPE ≥90 M BRANCH
PIPE DIAMETER MM (INCHES)
BRANCH
GAS
LIQUID
KCMI 212
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 212
Ø25.4 (1")
Ø12.7 (1/2”)
KCMI 312
Ø12.7 (1/2”)
KCMI 312
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
KCMI 212
45 kW
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
KCMI 312
From 50 to 61.5 kW
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
67 kW
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
From 73 to 95 kW
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 412 KCMI 412
From 100 to 140 kW
Ø41.3 (1”-5/8)
Ø19.1 (3/4”)
KCMI 412
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
From 145 to 185 kW
Ø41.3 (1”-5/8)
Ø22.2 (7/8”)
KCMI 412
Ø53.9 (2”-1/8)
Ø25.4 (1”)
KCMI 512
From 190 kW to 246 kW
Ø53.9 (2”-1/8)
Ø25.4 (1”)
KCMI 512
Ø53.9 (2”-1/8)
Ø25.4 (1”)
KCMI 512
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and intermediate pipes (L1,L2,L3,L4,L5) and their respective drifters (A,B,C): TABLE B CAPACITY OF UNITS CONECTED TO BRANCH OR OUTDOOR UNIT (x100W)
LENGTH BETWEEN THE FIRST BRANCH AND THE FARTHEST INDOOR UNIT ≤40 M. PIPE DIAMETER MM (INCHES) GAS
LIQUID
A<166
Ø15.9 (5/8”)
Ø9.5 (3/8”)
166≤A<230
Ø19.1 (3/4”)
Ø9.5 (3/8”)
BRANCH
LENGTH BETWEEN THE FIRST BRANCH AND THE FARTHEST INDOOR UNIT >40 M. PIPE DIAMETER MM (INCHES)
BRANCH
GAS
LIQUID
KCMI 112
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 112
KCMI 112
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 212 KCMI 312
230≤A<330
Ø22.2 (7/8")
Ø9.5 (3/8”)
KCMI 212
Ø25.4 (1")
Ø12.7 (1/2”)
330≤A<460
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
KCMI 312
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
KCMI 312
460≤A<660
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 312
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
KCMI 412
660≤A<920
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 412
920≤A<1350
Ø41.3 (1”-5/8)
Ø19.1 (3/4”)
KCMI 412
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 412
1350≤A<1800
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 412
Ø53.9 (2”-1/8)
Ø22.2 (7/8")
KCMI 512
1800≤A
Ø53.9 (2”-1/8)
Ø25.4 (1")
KCMI 512
Ø53.9 (2”-1/8)
Ø25.4 (1")
KCMI 512
A - Indoor units capacity
Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2 and L1>=L3>=L4 or L5.
3 Selection of the right pipe for indoor units (a,b,c,d,e,f) TABLE C DISTANCE BETWEEN BRANCH AND INDOOR UNIT ≤10 M
INDOOR UNIT TOTAL CAPACITY (x100W)
DISTANCE BETWEEN BRANCH AND INDOOR UNIT >10 M*
PIPE DIAMETER MM (INCHES)
PIPE DIAMETER MM (INCHES)
GAS
LIQUID
GAS
LIQUID
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
Ø19.1 (3/4”)
Ø12.7 (1/2”)
200
Ø19.1 (3/4”)
Ø9.5 (3/8”)
Ø22.2 (7/8")
Ø12.7 (1/2”)
250
Ø22.2 (7/8")
Ø9.5 (3/8”)
Ø25.4 (1")
Ø12.7 (1/2”)
280
Ø22.2 (7/8")
Ø9.5 (3/8”)
Ø25.4 (1")
Ø12.7 (1/2”)
400
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
450
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
560
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
Note: *Applicable only when upper pipe is equal or higher than the diameter of the selected pipe. L4>=c and d. For 400,450 and 560kW capacities, when there are more than 40 metres from the first drifter to the unit, please refer the right side of Table B.
252
A - Capacity of indoor unit/units
Inspiration, Innovation, Evolution
4 Selection of drifters (L,M,N) and pipes (G1,G2,g1,g2,g3,g4) of outdoor unit when there is more than one outdoor module. TABLE D NUMBER OF ONLINE OUTDOOR UNITS
BRANCH MODEL
2 (L)
KCME 12
PIPE DIAMETER MM (INCHES)
OUTDOOR UNIT MODULES CAPACITY
PIPES
GAS
LIQUID
Not required
3 (L and M)
KCME 13
G1
All possibilities
Ø41.3 (1”-5/8)
Ø19.1 (3/4”)
4 (L, M and N)
KCME 14
G2
All possibilities
Ø41.3 (1”-5/8)
Ø22.2 (7/8”)
From 25.2 to 33.5 kW
Ø25.4 (1")
Ø12.7 (1/2”)
From 40 to 61.5 kW
Ø34.9 (1”-3/8)
Ø15.9 (5/8”)
g1,g2,g3 and g4
L
M
N
N1 a N2
B
L1
A
L2 L3
C
b L4
N3
c
D
d
L5
N4 E
Important:
e f
N6 N5
Each elbow and drifter equals to a pipe of 0.5 metres. AMAZON INDUSTRIAL VRF
The minimum distance between branch pipes is 0.5m.
253
INDUSTRIAL VRF RANGE MEASURING
AMAZON III PRO
3 PIPES
HOW TO CHOOSE THE BRANCH AND THE REFRIGERANT PIPELINE
1 Selection of main pipe (L1) and its relevant drifter (A) TABLE A TOTAL LENGTH OF LIQUID PIPE <90 M CAPACITY OF OUTDOOR UNIT
TOTAL LENGTH OF LIQUID PIPE ≥90 M
PIPE DIAMETER MM (INCHES)
25.2 kW
HIGH-PRESSURE GAS Ø22.2 (7/8")
HIGH-PRESSURE GAS Ø19.1 (3/4”)
Ø9.5 (3/8”)
28 kW
Ø22.2 (7/8")
Ø19.1 (3/4”)
Ø12.7 (1/2”)
BRANCH
LIQUID
PIPE DIAMETER MM (INCHES)
BRANCH
KCMI 213
HIGH-PRESSURE GAS Ø22.2 (7/8")
HIGH-PRESSURE GAS Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 213
KCMI 213
Ø22.2 (7/8")
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 213
LIQUID
33.5 kW
Ø25.4 (1")
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 313
Ø25.4 (1")
Ø19.1 (3/4”)
Ø15.9 (5/8”)
KCMI 313
From 40 to 45 kW
Ø28.6 (1”-1/8)
Ø22.2 (7/8")
Ø15.9 (5/8”)
KCMI 313
Ø28.6 (1”-1/8)
Ø22.2 (7/8")
Ø15.9 (5/8”)
KCMI 313
From 50 to 61.5 kW
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 413
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø19.1 (3/4”)
KCMI 413
67 kW
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
KCMI 413
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø19.1 (3/4”)
KCMI 413
From 73 to 95 kW
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø19.1 (3/4”)
KCMI 413
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø22.2 (7/8")
KCMI 413
From 100 to 140 kW
Ø41.3 (1”-5/8)
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 513
Ø41.3 (1”-5/8)
Ø34.9 (1”-3/8)
Ø22.2 (7/8")
KCMI 513
From 145 to 185 kW
Ø53.9 (2”-1/8)
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 513
Ø53.9 (2”-1/8)
Ø41.3 (1”-5/8)
Ø25.4 (1")
KCMI 513
Note: To select the main pipe, use the greater diameter between A and B.
2 Selection of main and intermediate pipes (L1,L2,L3,L4,L5,L6,L7,L8,L9,L10,L11) and their respective drifters (A,B,C,D,E): TABLE B CAPACITY OF UNITS CONECTED TO BRANCH OR OUTDOOR UNIT (x100W)
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M
DISTANCE BETWEEN FIRST BRANCH PIPE AND THE FARTHEST INDOOR UNIT ≤40 M
PIPE DIAMETER MM (INCHES)
PIPE DIAMETER MM (INCHES) BRANCH
A<56
HIGHPRESSURE GAS Ø12.7 (1/2”)
HIGHPRESSURE GAS Ø9.5 (3/8”)
Ø6.4 (1/4”)
56≤A<166
Ø19.1 (3/4”)
Ø15.9 (5/8”)
Ø9.5 (3/8”)
BRANCH
KCMI 113
HIGHPRESSURE GAS Ø15.9 (5/8”)
HIGHPRESSURE GAS Ø12.7 (1/2”)
Ø9.5 (3/8”)
KCMI 113
KCMI 113
Ø22.2 (7/8")
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 213
LIQUID
LIQUID
166≤A<230
Ø22.2 (7/8")
Ø19.1 (3/4”)
Ø9.5 (3/8”)
KCMI 213
Ø25.4 (1")
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 313
230≤A<330
Ø22.2 (7/8")
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 213
Ø25.4 (1")
Ø22.2 (7/8")
Ø15.9 (5/8”)
KCMI 313
330≤A<460
Ø28.6 (1”-1/8)
Ø22.2 (7/8")
Ø12.7 (1/2”)
KCMI 313
Ø34.9 (1”-3/8)
Ø25.4 (1")
Ø15.9 (5/8”)
KCMI 313
460≤A<660
Ø28.6 (1”-1/8)
Ø22.2 (7/8")
Ø15.9 (5/8”)
KCMI 313
Ø34.9 (1”-3/8)
Ø25.4 (1")
Ø19.1 (3/4”)
KCMI 413
660≤A<920
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø19.1 (3/4”)
KCMI 413
Ø41.3 (1”-5/8)
Ø34.9 (1”-3/8)
Ø22.2 (7/8")
KCMI 513
920≤A<1350
Ø41.3 (1”-5/8)
Ø34.9 (1”-3/8)
Ø19.1 (3/4”)
KCMI 513
Ø53.9 (2”-1/8)
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 513
1350≤A
Ø53.9 (2”-1/8)
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 513
Ø53.9 (2”-1/8)
Ø41.3 (1”-5/8)
Ø22.2 (7/8")
KCMI 513
Note: The left side of this table corresponds to L1. Intermediate pipes may not be larger than the upper pipe. L1>=L2>=L3>=L4 or L1>=L7>=L9.
A - Indoor units capacity
3 Selection of pipes in indoor units (a,b,c,d,e,f,g,h,i,j,k,l,m,n) and their respective drifters (F,G,H,I) TABLE C CAPACITY OF INDOOR UNIT (x100W)
LENGTH BETWEEN KVB BOX/BRANCH AND INDOOR UNIT ≤10 M PIPE DIAMETER MM (INCHES) GAS
LIQUID
LENGTH BETWEEN KVB BOX/BRANCH AND INDOOR UNIT >10 M* BRANCH
PIPE DIAMETER MM (INCHES) GAS
LIQUID
BRANCH
A≤45
Ø12.7 (1/2”)
Ø6.4 (1/4”)
KCMI 112
Ø15.9 (5/8”)
Ø9.5 (3/8”)
KCMI 112
56≤A≤160
Ø15.9 (5/8”)
Ø9.5 (3/8”)
KCMI 112
Ø19.1 (3/4”)
Ø12.7 (1/2”)
KCMI 112
200
Ø19.1 (3/4”)
Ø9.5 (3/8”)
Ø22.2 (7/8")
Ø12.7 (1/2”) Ø12.7 (1/2”)
250
Ø22.2 (7/8")
Ø9.5 (3/8”)
Ø25.4 (1")
280
Ø22.2 (7/8")
Ø9.5 (3/8”)
Ø25.4 (1")
Ø12.7 (1/2”)
400
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
450
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
Ø28.6 (1”-1/8)
Ø12.7 (1/2”)
560
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
Ø28.6 (1”-1/8)
Ø15.9 (5/8”)
Not applicable
Not applicable
A - Indoor units capacity
254
Inspiration, Innovation, Evolution
4 Selection of drifters (L,M,N) and pipes (G1,G2,g1,g2,g3,g4) of outdoor unit when there is more than one outdoor module. TABLE D NUMBER OF ONLINE OUTDOOR UNITS
BRANCH MODEL
2 (L)
KCMER 32
PIPES
OUTDOOR UNIT MODULES CAPACITY
PIPE DIAMETER MM (INCHES) HIGH-PRESSURE GAS
HIGH-PRESSURE GAS
LIQUID
Not required
3 (L and M)
KCMER 33
G1
All possibilities
Ø34.9 (1”-3/8)
Ø28.6 (1”-1/8)
Ø19.1 (3/4”)
4 (L, M and N)
KCMER 34
G1 and G2
All possibilities
Ø41.3 (1”-5/8)
Ø34.9 (1”-3/8)
Ø22.2 (7/8")
From 25.2 to 33.5 kW
Ø22.2 (7/8")
Ø19.1 (3/4”)
Ø12.7 (1/2”)
From 40 to 45 kW
Ø28.6 (1”-1/8)
Ø22.2 (7/8")
Ø15.9 (5/8”)
g1,g2,g3 and g4
L
M
N
5 Selection of KVB boxes (1,2,3,4,5,6) TABLE E CAPACITY PER OUTPUT MODEL
CAPACITY (KW)
QUANTITY (NO)
CAPACITY (KW)
QUANTITY (NO)
Max. IU
Max. IU
Max. IU
Max. IU
KVBM2 DN3
16
KVBM4 DN3
16
KVBM6 DN3
16
KVBH2 DN3
4
Not applicable
28
8
45
16
45
24
28 56
1
AMAZON INDUSTRIAL VRF
KVBH4 DN3
CAPACITY PER KVB
Important: Each elbow and drifter equals to a pipe of 0.5 metres. The minimum distance between branch pipes is 0.5m.
255
INDUSTRIAL VRF RANGE MEASURING
DISTANCES AND HEIGHTS
2 PIPES
MINI AMAZON II
8/10,5 KW
Total length from outdoor unit to all the indoor units.
PIPING LENGTH
Length between the outdoor unit and the furthest indoor unit.
≤45m
≤60m
Equivalent
≤50m
≤70m
Length between one indoor unit and the closest distributor
HEIGHT DIFFERENCE
≤100m
Real
Length between the first distributor and the furthest indoor unit.
Level difference between outdoor unit and indoor unit
12/14/16/18KW
≤20 (40m*) 15m
The outdoor unit is higher than the indoor unit
≤30m
The outdoor unit is lower than the indoor unit
≤20m
Level difference between indoor units
≤8m
*Check for lengths between 20 and 40 metres.
AMAZON IV PRO
ALL MODULES
Total length from outdoor unit to all the indoor units.
PIPING LENGTH
Length between the outdoor unit and the furthest indoor unit.
Real
≤ 175m
Equivalent
≤ 200m
Length between the first distributor and the furthest indoor unit. Length between one indoor unit and the closest distributor
HEIGHT DIFFERENCE
Level difference between outdoor unit and indoor unit
≤ 1000m
≤ 40 (90m*) -
The outdoor unit is higher than the indoor unit
≤ 110m
The outdoor unit is lower than the indoor unit
≤90m
Level difference between indoor units
≤ 30m
*Check for lengths between 40 and 90 metres.
AMAZON III W
8/10/12 HP
Total length from outdoor unit to all the indoor units.
PIPING LENGTH
Length between the outdoor unit and the furthest indoor unit.
Real
≤120m
Equivalent
≤150m
Length between the first distributor and the furthest indoor unit. Length between one indoor unit and the closest distributor
HEIGHT DIFFERENCE
Level difference between outdoor unit and indoor unit
Level difference between indoor units
*Check for lengths between 40 and 90 metres.
256
≤300m
≤40 (90 m*) -
The outdoor unit is higher than the indoor unit
≤50m
The outdoor unit is lower than the indoor unit
≤40m ≤30m
Inspiration, Innovation, Evolution
MINI AMAZON II OUTDOOR UNIT INDOOR UNITS
30m 8m
50m (70m)
20m (40m)
AMAZON IV PRO
OUTDOOR UNIT INDOOR UNITS
110m 30 m
AMAZON INDUSTRIAL VRF
200 m
40m (90m)
AMAZON III W
OUTDOOR UNIT INDOOR UNITS
50m
150 m
30 m
40m (90m)
257
INDUSTRIAL VRF RANGE MEASURING
DISTANCES AND HEIGHTS
2 PIPES
AMAZON UNITARIO FRONT AIR DISCHARGE
20/22/24 KW
40/45 KW
≤120m
≤250m
Real
≤60m
≤100m
Equivalent
≤70m
≤120m
Length between the first distributor and the furthest indoor unit.
≤20m
≤40 m
Length between one indoor unit and the closest distributor
≤15m
≤15m
The outdoor unit is higher than the indoor unit
≤30m
≤30m
The outdoor unit is lower than the indoor unit
≤20m
≤20m
≤8m
≤8m
10-16 HP
20/22/24 HP
≤350m
≤1000m
Real
≤150m
≤175m
Equivalent
≤175m
≤200m
Length between the first distributor and the furthest indoor unit.
≤40
≤40 (90m*)
Length between one indoor unit and the closest distributor
≤15
≤15
The outdoor unit is higher than the indoor unit
≤70m
≤110m
The outdoor unit is lower than the indoor unit
≤50m
≤70m
≤15m
≤30m
Total length from outdoor unit to all the indoor units.
PIPING LENGTH
HEIGHT DIFFERENCE
Length between the outdoor unit and the furthest indoor unit.
Level difference between outdoor unit and indoor unit
Level difference between indoor units
AMAZON UNITARIO TOP AIR DISCHARGE DN3 Total length from outdoor unit to all the indoor units.
PIPING LENGTH
HEIGHT DIFFERENCE
Length between the outdoor unit and the furthest indoor unit.
Level difference between outdoor unit and indoor unit
Level difference between indoor units
*Check for lengths between 40 and 90 metres.
AMAZON UNITARIO TOP AIR DISCHARGE DN4 S Total length from outdoor unit to all the indoor units.
PIPING LENGTH
Length between the outdoor unit and the furthest indoor unit.
≤ 175m
Equivalent
≤ 200m
Length between one indoor unit and the closest distributor
HEIGHT DIFFERENCE
Level difference between indoor units
*Check for lengths between 40 and 90 metres.
258
≤ 1000m
Real
Length between the first distributor and the furthest indoor unit.
Level difference between outdoor unit and indoor unit
ALL MODULES
≤ 40 (90m*) -
The outdoor unit is higher than the indoor unit
≤ 110m
The outdoor unit is lower than the indoor unit
≤90m ≤ 30m
Inspiration, Innovation, Evolution
AMAZON UNITARIO FRONT AIR DISCHARGE
OUTDOOR UNIT INDOOR UNITS
30m 8m
70m (120m)
20m (40m)
AMAZON UNITARIO TOP AIR DISCHARGE DN3
OUTDOOR UNIT INDOOR UNITS
50m 30 m
AMAZON INDUSTRIAL VRF
150 m
40m (90m)
AMAZON UNITARIO TOP AIR DISCHARGE DN4 S OUTDOOR UNIT INDOOR UNITS
110m
200 m
30 m
40m (90m)
259
INDUSTRIAL VRF RANGE MEASURING
DISTANCES AND HEIGHTS
3 PIPES
AMAZON III PRO 3-DUCTS
AMAZON III PRO
ALL MODULES
Total length from outdoor unit to all the indoor units.
PIPING LENGTH
Length between the outdoor unit and the furthest indoor unit.
≤175 m
Equivalent
≤200 m
Length between the first distributor and the furthest indoor unit.
HEIGHT DIFFERENCE
Level difference between outdoor unit and indoor unit
≤1000 m
Real
≤40m (90 m)
The outdoor unit is higher than the indoor unit
≤110m
The outdoor unit is lower than the indoor unit
≤ 70 m
Level difference between indoor units
≤ 30 m
*Length between the KVB box and the furthest indoor unit. 40 m. *Check for lengths between 40 and 90 metres.
AMAZON III PRO
OUTDOOR UNIT INDOOR UNITS
110m
200 m
40m (90m)
260
30 m
SELECTA
Inspiration, Innovation, Evolution
COOLING SIZING SYSTEM Selecta software download
1 Please, enter project’s data and information. 2 Calculate the load of the project. 3 Select outdoor and indoor units. 4 Project’s pipes diagram. 5 Select controller.
AMAZON INDUSTRIAL VRF
Congratulations! Your project is ready.
261
INDUSTRIAL VRF RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
CEPSA LABORATORIES BUSINESS CENTRE Location: Huelva Units installed: Amazon 2 pipes Capacity: 30 kW
262
AMAZON INDUSTRIAL VRF
Inspiration, Innovation, Evolution
263
INDUSTRIAL VRF RANGE KEY INSTALLATIONS
BUENAVISTA CONFERENCE CENTRE METROPOL PARASOL “LAS SETAS” BUSINESS CENTRE PUBLIC BUILDING Location: Oviedo Location: Seville New construction Initial situation: Units installed: 2 pipes Units installed:Amazon Zen Inverter Capacity: 200 kW Capacity: 140 kW
THE AMAZON RANGE OFFERS THE MOST VERSATILE RANGE OF CAPACITIES AND COMBINABLE INDOOR AND OUTDOOR UNITS. AMAZON UNITS HAVE THE HIGHEST TECHNOLOGY FOR LARGE FACILITIES, ALWAYS RESPECTING THE ENVIRONMENT.
OTHER CUSTOMERS THAT HAVE TRUSTED IN KAYSUN HOTELS Ciudad de Alcañiz Hotel (Teruel), Eritaña Civil Guard Headquarters (Seville), Dolce Fregate Hotel (Provence), Ibis Hotel (Seville). PUBLIC BUILDINGS Óvalo Centro Social Services building (Zaragoza), Deputy Major's Office (Málaga), Reus Town Council (Tarragona), ADIF Railway Infrastructures Manager Offices (Asturias), Department of Agriculture (Badajoz).
264
SCHOOLS AND UNIVERSITITES San Luis School (Minorca), Camino de Gelves Nursery School (Seville). HOSPITALS, HEALTH CLINICS AND CENTRES Adharaz School (Seville), Altasierra School (Seville), San Francisco de Paula School (Seville), Calasancio School (Córdoba), Pablo de Olavide University (Seville), Guijuelo Nursery School (Salamanca), University School of Technical
Industrial Engineering (Barcelona), Santa Maria del Pilar School (Madrid), Sagrado Corazón Health Clinic (Seville). RESIDENCES Palacio de la calle Mayor Residence (Madrid). LEISURE CENTRES Sant Josep Sports Centre (Barcelona), Amezketa Library (Guipúzcoa), Requejada Sports Centre (Cantabria), School of Music (Jerez de la Frontera), Conferences and Exhibition Centre (Madrid)
Pinto Library (Madrid). BUSINESS CENTRES AND OFFICES Mercedes Authorised Dealer (Barcelona), Caritas charitable organisation (Barcelona), ThyssenKrupp Elevators (Barcelona), Aceites Abril S.L. (Ourense), Zara Home (Vitoria), Aki (Granollers).
Inspiration, Innovation, Evolution
LEFTIES
CAMBRILS PARK RESORT
CASTILLO DE ARTEAGA
COMMERCIAL BUILDING
CAMPING RESORT
HOTEL
Location: France and Belgium Units installed: Amazon 2 pipes Capacity: 50 kW
Location: Cambrils (Tarragona) Units installed: Amazon 3 pipes Capacity: 2000 kW
Location: Arteaga (Vizcaya) Units installed: Amazon 3 pipes Capacity: 1000 kW
DOLCE FREGATE
VIDIGUEIRA
INSTITUTO POLITÉCNICO DO PORTO
HOTEL
WINE CELLAR
POLYTECHNIC COLLEGE
Location: Provence (France) Units installed: Amazon 2 pipes Capacity: 160 kW
Location: Vidigueira (Portugal) Units installed: K2F-615DN4S Capacity: 61.5kW
Location: Porto (Portugal) Units installed: 2x K2F-450DN3 Capacity: 90kW
MERCURE HOTELS
ALL SUITES
HOTEL
APART HOTEL
AMAZON INDUSTRIAL VRF
HYUNDAI – CENTRAL MOTOR DEALERSHIP
Location: Lyon (France)
Location: Ibiza Initial situation: Renovation Units installed: Minichillers Capacity: 251 kW
Location: Pessac (France) Units installed: 3 pipes
COURS BASTIDE
AMD DECOLLETAGE
DUBLIN
SCHOOL
AUTOMOTIVE COMPONENTS FACTORY
HOTEL
Location: Marseille (France)
Location: Marnaz (France) Units installed: K2F-615DN4S Capacity: 61.5kW
Location: Dublin (Ireland) Units installed: Amazon Unitario
265
CONTROLS CONTROL SYSTEM RANGE
INTRODUCTION TO THE PRODUCT RANGE................................. 268 OUR RANGE OF PRODUCTS..................................................... 269 WIRELESS SINGLE AND WIRED CONTROLLERS.................... 270 CENTRALISED............................................................................ 272 INTEGRATED CONTROLLERS................................................... 274 ACCESSORIES............................................................................. 282 KEY INSTALLATIONS..................................................................... 284
CONTROL SYSTEM RANGE
CONTROL SYSTEMS
CONTROLS
CONTROLS
CONTROL SYSTEMS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
CONTROLS CONTROL SYSTEMS RANGE
Introducing the two new KAYSUN controllers range based on centralised control and fitted with touchscreen. KCCT-64 IPS and KCCT-384 IPS models are able to control 64 indoor units and 384 indoor units, respectively. Both controllers are fitted with a user-friendly intuitive touchscreen. The weekly timer and units groups control are some of their main functions available. Besides, KCCT-384 IPS controller allows the connection to its Web function through a LAN cable and includes plans of the unitsâ&#x20AC;&#x2122; location. Furthermore, KAYSUN offers a complete range of interfaces for BMS Lonworks, Bacnet, Modbus and KNX, v Kaynet control, a programme for managing KAYSUN cooling systems by computer.
KCCT-64 IPS
NEW
"COMPREHENSIVE SOLUTIONS AT YOUR FINGERTIPS" Finally, we would like to introduce the KCC-64 WEB controller, a new device that allows for the remote control of 64 indoor units through the Internet by Smartphone, Tablet or PC.
KCCT-384 IPS
Our new product for 2018 is this controller fitted with touchscreen. This is a user-friendly intuitive device fitted with the most advanced functions, such as units groups control, alarm buzzer, scheduler, parameters blocking, as well as operation mode and operating Temperature.
NEW
This new centralised controllers offers the same functions as KCCT 64 IPS model; however, it is able to control up to 384 indoor units in 6 ports, and 64 indoor units per port. It also provides users with exclusive functions, such a Web function to allow remote connection, as well as the possibility of displaying the plans of the building/house.
NEW
KC-03.1 SPS Based on the KC-03 SPS model, the standard controller of the range, we introduce the KC-03.1 SPS model. This device has been designed for Kaysun ducts units. It is able to adjust static pressure both automatically and manually, which makes it the perfect controller for these units. Besides, it is bidirectional, is fitted with a weekly timer and provides failures codes.
268
NEW
Inspiration, Innovation, Evolution
OUR RANGES INDIVIDUAL WIRELESS
(Page 270)
COMPATIBILITY
SUITE PRODIGY 1x1
AUREA II 1x1
ONNIX 1x1
PRODIGY 1x1
AUREA II 1x1
ONNIX 1x1
KSD 1x1
MULTI
KSD 1x1
MULTI
ZEN
AMAZON
ZEN
AMAZON
KID-02 S KI-02.3 S SINGLE WIRED
(Page 270)
COMPATIBILITY
SUITE
Except for Aurea II model
Except for SuperSlim Cassette and Floor Standing models
KC-03 SPS
Ducts and cassette
Except for SuperSlim Cassette and Floor Standing models
KC-03.1 SPS
Ducts and cassette
Except for SuperSlim Cassette and Floor Standing models
KCT-02.1 SR
Except for Aurea II model
Except for SuperSlim Cassette and Floor Standing models
KC-02.1 H
Except for Aurea II model
Except for SuperSlim Cassette and Floor Standing models
KC-01 S
NEW
CENTRALISED
SUITE
(Page 272)
COMPATIBILITY
PRODIGY 1x1
AUREA II 1x1
ONNIX 1x1
KSD 1x1
ZEN
AMAZON
ZEN
AMAZON
ZEN
AMAZON
MULTI
KMC-32 E KCCT-64 I (B)
Except for wall-mounted and KSD units.
NEW
KCCT-64 IPS
Except for wall-mounted and KSD units.
NEW
KCCT-384 IPS
Except for wall-mounted and KSD units.
KCC-64 WEB
Except for wall-mounted and KSD units.
PRODIGY 1x1
AUREA II 1x1
ONNIX 1x1
KSD 1x1
MULTI
K01-LON
Except for wall-mounted and KSD units.
K01-BACNET
Except for wall-mounted and KSD units.
K02-MODBUS
Except for wall-mounted and KSD units.
K01 MODBUS
Except for wall-mounted and KSD units.
KAYNET CONTROL
Except for wall-mounted and KSD units.
K01-KNX
Except for wall-mounted and KSD units.
CONTROL SYSTEMS
NEW
SUITE
(Page 274)
COMPATIBILITY
CONTROLS
BMS AND SOFTWARE
K01-WIFI ACCESSORIES
SUITE
(Page 282)
COMPATIBILITY
PRODIGY 1x1
K01-WATT
AUREA II 1x1
ONNIX 1x1
KSD 1x1
MULTI Except for MINI AMAZON II
KAHU 269
CONTROL SYSTEMS RANGE SINGLE WIRELESS AND WIRED CONTROLLERS
SINGLE WIRELESS AND WIRED KID-02 S
24ºC 24ºC
-
TURBO
+
GENERAL CHARACTERISTICS • • • • • • • • • • •
Wireless controller FOLLOW ME LED function Turbo function Silence function Night mode 8 ºC function Self-cleaning function Units operating parameters query Units operating parameters change Mute function
MODEL
COMPATIBLE WITH
KID-02 S
SUITE - ZEN
Check available functions for each unit. Standard in Prodigy, Onnix and Aurea ranges.
KI-02.3 S
26ºC
GENERAL CHARACTERISTICS • • • • •
Wireless controller Follow me function 26ºC function. AMAZON indoor units addressing AUTO mode activation/deactivation MODEL
COMPATIBLE WITH
KI-02.3 S
AMAZON
KC-01 S
26ºC
GENERAL CHARACTERISTICS • Wired controller • FOLLOW ME
MODEL
COMPATIBLE WITH
KC-01 S
SUITE* ZEN** AMAZON
* Except for Aurea II model ** Except for Superslim cassette and floor standing models
270
Inspiration, Innovation, Evolution
KC-03 SPS
x2
TWINS
GENERAL CHARACTERISTICS • Wired controller with 2 non-polarised wires • FOLLOW ME • Malfunction codes display • Weekly timer • Capacity to control up to 16 indoor units • Bidirectional
KC-03.1 SPS
MODEL KC-03 SPS
COMPATIBLE WITH SUITE* ZEN**
* Only Ducts ** Except for Superslim cassette and floor standing models
NEW
x2
TWINS
GENERAL CHARACTERISTICS • Wired controller with 2 non-polarised wires • FOLLOW ME • Malfunction codes display • Weekly timer • Automatic adjustment of static pressure in ducts units • Bidirectional
KC-02.1 H
MODEL KC-03 SPS
COMPATIBLE WITH SUITE* ZEN**
* Only Ducts ** Except for Superslim cassette and floor standing models
SPECIAL FOR HOTELS
GENERAL CHARACTERISTICS • Wired controller • Hotel-type simplified controller with Operation mode function hidden • 26ºC function • Memory function
MODEL
COMPATIBLE WITH
KC-02.1 H
SUITE* ZEN** AMAZON
CONTROLS
KCT-02.1 SR
CONTROL SYSTEMS
* Except for Aurea II model ** Except for Superslim cassette and floor standing models
26ºC
GENERAL CHARACTERISTICS • • • • • • •
Wired controller Follow me function Touch sensitive AMAZON indoor units addressing Filter cleaning alarm Built-in infrared signal receiver Memory function
MODEL KCT-02.1 SR
COMPATIBLE WITH SUITE* ZEN** AMAZON
* Except for Aurea II model ** Except for Superslim cassette and floor standing models
271
CONTROL SYSTEMS RANGE CENTRALISED
CENTRALISED KMC-32 E GENERAL CHARACTERISTICS • Centralised display for outdoors • Up to 32 modules • If outdoor unit is fitted with the K01-WATT wattmeter, total consumption of each module is displayed MODEL
COMPATIBLE WITH
KMC-32 E
KCCT-64 IPS
AMAZON
NEW
GENERAL CHARACTERISTICS • • • • • • • •
Indoor centralised controller 6.2” touchscreen User-friendly, intuitive Up to 64 indoor units Units Groups control Schedule timer Malfunction codes display Available in Spanish, English and French MODEL
COMPATIBLE WITH SUITE* ZEN AMAZON
KCCT-64 IPS *Except for wall-mounted and KSD units.
KCCT-64 I (B) GENERAL CHARACTERISTICS • • • •
Touch sensitive Indoor centralised controller Up to 64 indoor units Emergency stop MODEL
COMPATIBLE WITH
KCCT-64 I (B)
SUITE* ZEN AMAZON
*Except for wall-mounted and KSD units.
272
Inspiration, Innovation, Evolution
KCCT-384 IPS
NEW
GENERAL CHARACTERISTICS • Indoor centralised controller • 10.1” touchscreen • User-friendly, intuitive • Up to 384 indoor units • Units Groups control • Schedule timer
• Malfunction codes display • Available in Spanish, English and French • Web function • Building layout
MODEL
COMPATIBLE WITH
KCCT-384 IPS
SUITE* ZEN AMAZON
*Except for wall-mounted and KSD units.
KCC-64 WEB GENERAL CHARACTERISTICS Units control through WEB or Smartphone APP Indoor centralised controller Up to 64 indoor units Weekly timer Non-compatible with superior controls
NEW APP
NEW WEBSITE
MODEL KCC-64 WEB
COMPATIBLE WITH SUITE* ZEN AMAZON
CONTROL SYSTEMS
*Except for wall-mounted and KSD units.
CONTROLS
• • • • •
273
CONTROL SYSTEMS RANGE BMS AND SOFTWARE
BMS AND SOFTWARE K01-LON GENERAL CHARACTERISTICS • BMS interface, direct gateway to Lonworks • Centralised controllers not required • Up to 64 indoor units
MODEL
COMPATIBLE WITH SUITE* ZEN AMAZON
K01-LON *Except for wall-mounted and KSD units.
INSTALLATION EXAMPLE
K01-LON
SYSTEM 1 UP TO 64 INDOOR UNITS
X, Y, E
P, Q, E SYSTEM 2 P, Q, E
BMS
274 274
LONWORKS
SYSTEM N P, Q, E
Inspiration, Innovation, Evolution
K02-MODBUS GENERAL CHARACTERISTICS • BMS interface, direct gateway to MODBUS through RTU and TCP/IP. • Up to 64 indoor units and 4 outdoor units of the same cooling system. • Centralised controllers not required.
MODEL
COMPATIBLE WITH
KO2-MODBUS
SUITE* ZEN AMAZON
*Except for wall-mounted and KSD units.
INSTALLATION EXAMPLE
UP TO 64 INDOOR UNITS
P, Q, E X, Y, E
K02-MODBUS BMS
MODBUS
K1, K2, E
OUTDOOR UNITS
K1, K2, E UP TO 4 OUTDOOR UNITS OF THE SAME COOLING SYSTEM
K01-MODBUS
NEW
GENERAL CHARACTERISTICS
COMPATIBLE WITH
K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
SUITE* ZEN AMAZON
CONTROLS
MODEL
CONTROL SYSTEMS
• BMS interface, direct gateway to MODBUS through RTU (RS-485). • Power supply included. • Three interface types for 1, 4, 8 or 32 indoor units.
*Except for wall-mounted and KSD units.
INSTALLATION EXAMPLE RTU (RS-485)
BMS
XYE
MODBUS
275
CONTROL SYSTEMS RANGE BMS AND SOFTWARE
BMS AND SOFTWARE K01-BACNET GENERAL CHARACTERISTICS • • • •
Direct BMS interface to BACNET. 4 ports available for indoor and outdoor units. Up to 256 indoor units. Up to 128 outdoor units.
MODEL
COMPATIBLE WITH
K01-BACNET
SUITE* ZEN AMAZON
*Except for wall-mounted and KSD units.
INSTALLATION EXAMPLE
K01-BACNET
OUTDOOR UNITS K1,K2,E
INDOOR UNITS P,Q,E
XYE
HUB OUTDOOR UNITS
XYE
WITH IP Motorised System
276 276
BMS
BACNET PROTOCOL IP
INDOOR UNITS
P,Q,E
Inspiration, Innovation, Evolution
K01-KNX GENERAL CHARACTERISTICS • BMS interface, direct gateway to KNX. • Centralised controllers not required. • Three interface types, 1, 16 or 64 indoor units.
MODEL
COMPATIBLE WITH
KO1-KNX 1
SUITE* ZEN AMAZON
KO1-KNX 16 KO1-KNX 64 *Except for wall-mounted and KSD units.
INSTALLATION EXAMPLE INDOOR UNITS P.Q.E
P.Q.E
P.Q.E
KO1-KNX 1
XYE
KO1-KNX 1
CONTROL SYSTEMS
KO1-KNX 1
XYE
CONTROLS
XYE
OUTDOOR UNIT KNX CONTROL SYSTEM
277
CONTROL SYSTEMS RANGE BMS AND SOFTWARE
BMS AND SOFTWARE K01-WIFI GENERAL CHARACTERISTICS • The user connects via a web page or APP for IOS or Android and controls the air-conditioning units in an easy and intuitive way. A cloud server manages the whole process. • Centralised controllers not required. • Designed for controlling juts one unit. • Collaboration agreement with Intesis Home.
MODEL
COMPATIBLE WITH SUITE ZEN AMAZON
K01-WIFI
*INFRARED DEVICE
INSTALLATION EXAMPLE 1
2
SMARTPHONE
PC
TABLET
THE COMMAND IS SENT FROM OUR DEVICE
INFORMATION IS TRANSFERRED THROUGH THE CLOUD SERVER
3
4
+ 1
2
1 K01-WIFI device 2 External antenna A CONVENTIONAL ROUTER RECEIVES THE COMMAND IT SENDS THE SIGNAL TO OUR UNITS
278 278
THE INDOOR UNIT RUNS THE COMMAND
Inspiration, Innovation, Evolution
REMOTE CONTROLLER OF YOUR AIR CONDITIONER
K01-WIFI
ADVANTAGES
+
TURN YOU EQUIPMENT ON AND OFF
+
CHANGE THE FUNCTION (HEAT, COOL, DRY...)
+
CONTROL THE POSITION OF THE LOUVRES
+
DISPLAY THE TEMPERATURE IN YOUR HOUSE
SMARTPHONE
PC
TABLET
INSTANT CONTROL ANYWHERE
¿HOW DOES IT WORK?
•
Switch on the Air Conditioning before arriving home.
•
Change the automatic switch on programme if you are going to arrive later.
•
Know the temperature in the rooms of your house at all times. CONTROL SYSTEMS
Control all the Air Conditioning units via the Internet from a website or from an application for your Smartphone or Tablet.
CONTROLS
WHAT DO YOU NEED? You only need to install a small device into your air-conditioning unit to begin remotely controlling your units. The WIFI router at your place will send your commands.
DOES IT TAKE UP SPACE ON MY OPERATION INTERFACE EXAMPLE
MOBILE DEVICE? No! All the information necessary for the operation of the new K01-WIFI control is stored in the cloud during the process. 279
CONTROL SYSTEMS RANGE BMS AND SOFTWARE
BMS AND SOFTWARE KAYNET CONTROL GENERAL CHARACTERISTICS • A KAYSUN solution for a comprehensive control of your units. • Up to 16 cooling circuits. • Up to 256 indoor units. • Up to 64 outdoor units. • Centralised controllers not required. • Simple Web control though IP or software. • Network control software included. MODEL
COMPATIBLE WITH SUITE* AMAZON ZEN
KAYNET CONTROL *Except for wall-mounted and KSD units.
INSTALLATION EXAMPLE PC KAYNET CONTROL
4
XYE KIK2E INDOOR UNITS
PQE
XYE KIK2E INDOOR UNITS
PQE
XYE KIK2E
INDOOR UNITS
PQE
XYE KIK2E
INDOOR UNITS
PQE
280 280
PC UP TO 4 KAYNET CONTROLS
SCHEDULE
GROUPS
LIMITATION/BLOCK
BUILDING LAYOUT
CONSUMPTION CONTROL AND RECORD
START AND STOP RECORD
COMMANDS AND ACCESSES RECORD
CONTROLS
MAIN DISPLAY
CONTROL SYSTEMS
Inspiration, Innovation, Evolution
281
CONTROL SYSTEMS RANGE ACCESSORIES.
ACCESSORIES. KAHU GENERAL CHARACTERISTICS • Interface to connect a cooling unit with a direct expansion coil to the AMAZON (VRF) systems. • It has an additional indoor unit. • Power from 9 to 56 kW. • More than one unit can be connected at the same time to increase the connectable power.
MODEL
COMPATIBLE WITH
KAHU-200.2 KAHU-360.2
AMAZON
KAHU-560.2
INSTALLATION EXAMPLE
KAHU
OUTDOOR UNIT
PQE Liquid cooling pipeline
Gas cooling pipeline
MARKET CLIMATE CONTROL WITH DIRECT EXPANSION BATTERY
282
INDOOR UNITS
Inspiration, Innovation, Evolution
K01-WATT GENERAL CHARACTERISTICS • Digital wattmeter. • One controller for each outdoor module. • Consumption can be displayed through the KMC-32 E and KAYNET control.
MODEL
COMPATIBLE WITH
K01-WATT
AMAZON*
*Except for MINIAMAZON II systems.
INSTALLATION EXAMPLE OUTDOOR UNITS
INDOOR UNITS
O, A, E PORT
O, A, E PORT
O, A, E PORT
O, A, E PORT
PQE
CONTROLS
CONTROL SYSTEMS
KO1-WATT KO1-WATT KO1-WATT KO1-WATT
283
CONTROL SYSTEMS RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
CASA ÁRABE PUBLIC BUILDING Location: Madrid Units installed: KAYNET
KAYSUN AND THE LATEST TECHNOLOGY GO HAND IN HAND AS IT FORGES AHEAD TO OFFER THE BEST IN AIR-CONDITIONING CONTROL UNITS. INSPIRATION, INNOVATION AND PROGRESS ARE REFLECTED IN THIS RANGE, BRINGING THE NEWEST LOOK AND BEST FEATURES TO ALL OF OUR CONTROL DEVICES.
284
Inspiration, Innovation, Evolution
KOMKAL INDUSTRIAL BUILDING
Location: Reus (Tarragona) Units installed: MODBUS
DOLCE FREGATE
CONTROLS
CONTROL SYSTEMS
HOTEL
Location: Provence (France) Units installed: KAYNET
285
NEXUS CHILLERS RANGE
INTRODUCTION TO THE PRODUCT RANGE.......................................................... ..288 CHILLERS..........................................................................................................................292 MINICHILLERS FULL DC INVERTER...............................KEM D(V)(T)N........... ..294 MODULAR FULL DC INVERTER CHILLERS....................KEM DNS3................ ..296 FULL DC INVERTER CHILLERS WITH HYDRAULIC KIT.......................................................KEM DNS3 KH.......... ..298 FIXED SCROLL MODULAR CHILLERS.............................KEM HN3..................... 300 EXTERNAL HYDRAULIC KITS..........................................KH.............................. ..302 ROTARY SCREW CHILLERS.................................................................................. 304 CENTRIFUGAL CHILLERS...................................................................................... 306 KEY INSTALLATIONS................................................................................................... 308
NEXUS NEXUS CHILLERS
CHILLERS RANGE
CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
NEXUS CHILLERS RANGE
The new 2018 KAYSUN chillers range has a wide range of units to meet each and every requirement of any premises. The KAYSUN Nexus series is the ideal solution for spaces that require climate control, such as homes, hotels, offices, stores and other facilities. All units in this range use environmentally and ozone-friendly refrigerant.
“THE FLOW OF THE MOST ADVANCED TECHNOLOGY”
MODULAR CHILLERS KAYSUN offers an extensive range of modular units with great versatility thanks to its combinable basic modules. Both design and installation process of this units are highly flexible, adding and combining chillers according to the needs of any customer or premises.
REFRIGERANT INLET
MODULAR FULL DC INVERTER CHILLERS New modular 30kW and 60kW chillers fitted with Full DC Inverter technology. Up to four modules of these units can be combined, allowing us to achieve capacities of up to 240 kW. Fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and high energy savings. Compact structure units designed for convenient access and maintenance.
WATER INLET
REFRIGERANT OUTLET
HOT PLATE
WATER OUTLET
EXCHANGER TYPE Full DC Inverter chillers are fitted with a plate heat exchanger.
288
+
TWIN ROTARY DC INVERTER COMPRESSORS
+
DC INVERTER VENTILATORS
+
COMPACT STRUCTURE
Inspiration, Innovation, Evolution
FIXED SCROLL The 130kW, 185kW and 250kW fixed Scroll chillers, can be also combined with four 250 kW units, thereby achieving 1MW of maximum cooling power.
x4
COMBINABLE UP TO 1000 kW
EXCHANGER TYPE Fixed Scroll Chillers are fitted with a multitubular heat exchanger. Multitubular System GAS OUTLET
GAS INLET
WATER INLET
WATER OUTLET
FULL DC INVERTER CHILLER UNITS WITH BUILT-IN HYDRAULIC KIT 30kW and 60 kW Full DC Inverter Chillers with incorporated hydraulic kit. These units are fitted with DC Inverter Twin Rotary compressors and DC Brushless ventilators to ensure high efficiency and the resulting energy savings. Compact structure units designed for convenient access and maintenance.
TWIN ROTARY DC INVERTER COMPRESSORS
+
DC INVERTER FAN MOTORS
+
COMPACT STRUCTURE
+
BUILT-IN HYDRAULIC KIT
NEXUS CHILLERS
+
289
CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
FULL DC INVERTER MINICHILLERS Minichiller units with 12, 14 and 16 kW rotary Inverter compressors provide up to 3.39 EER and up to 3.50 COP. This enhancement turns these units into a very efficient option to be considered for residential hot water installations.
REFRIGERANT INLET
WATER INLET
REFRIGERANT OUTLET
WATER OUTLET
HOT PLATE
EXCHANGER TYPE These units are fitted with a plate exchanger.
HYDRAULIC KIT INVERTER MINICHILLERS
Minichiller units are delivered with a complete built-in hydraulic kit.
ROTARY SCREW CHILLERS KAYSUN’SNEXUS range has large chillers with screw compressors. These units can operate condensed by air or water. Besides, all units are fitted with Bitzer bi-screw compressors and regulate refrigerant through an electronic expansion valve. These units have a capacity of between 340 and 1780 kW. They also incorporate multi-tubular evaporators and control is carried out using a microprocessor with a 10.7” touchscreen.
CENTRIFUGAL CHILLERS KAYSUN introduces its most powerful range of chillers, thanks to to the addition of centrifugal compressors.. They are available in three different options according on their efficiency. From standard units to high-efficiency and, eventually, super high-efficiency units, with 7.11 EER.
290
Inspiration, Innovation, Evolution
UNITS
NEXUS NEXUS CHILLERS CHILLERS
TECHNICAL SPECIFICATIONS
291
CHILLERS RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
POWER RANGE
FULL DC INVERTER MINICHILLERS POWER
kW
(Page 294)
5
7
10
12
KEM-7 DVN1
KEM-10 DVN
KEM-12 DVN
14
16
20
25
KEM-12 DTN
KEM-14 DTN
KEM-16 DTN
12
14
16
20
25
200
225
250
300
350
690
720
SINGLE-PHASE KEM-5 DVN1
TRI-PHASE
MODULAR FULL DC INVERTER CHILLERS
POWER kW
(Page 296)
5
7
10
WITHOUT HYDRAULIC KIT
WITH HYDRAULIC KIT
FIXED SCROLL MODULAR CHILLERS
POWER kW
130
180
(Page 300)
COMBINABLE UP TO 4 MODULES KEM-130 HN3
CHILLERS SCREW
POWER kW
340
380
KEM-200 HN3
440
500
KEM-250 HN3
540
600
(Page 304)
AIR-WATER CONSULT MODEL
WATER-WATER CONSULT MODEL
CHILLERS CENTRIFUGAL
2
MW
3
4
(Page 306)
HIGH CAPACITY CONSULT MODEL
292
5
Inspiration, Innovation, Evolution
30
35
40
45
50
55
60
65
30
35
40
45
50
55
60
65
COMBINABLE UP TO 4 MODULES KEM-30 DNS3
KEM-60 DNS3
KEM-30 DNS3 KH
KEM-60 DNS3 KH
400
450
500
550
600
650
700
750
805
890
900
1000
1080
1200
1385
1400
1620
1780
CONSULT MODEL
6
7
8
NEXUS CHILLERS
CONSULT MODEL
9
CONSULT MODEL
293
CHILLERS RANGE MINICHILLERS
MINICHILLERS FULL DC INVERTER TECHNICAL SPECIFICATIONS INVERTER
KEM-5 DVN1 KEM-7 DVN1 KEM-10 DVN KEM-12 DVN KEM-12 DTN KEM-14 DTN KEM-16 DTN
MODEL Power Cooling capacity Cooling input
V-FHz kW
220/1/~50
220/1/~50
220/1/~50
220/1/~50
380/3/~50
380/3/~50
380/3/~50
5 (1.9 ~ 5.8)
7 (2.1 ~ 7.8)
10.0 (2.9 ~ 10.5)
11.2 (3.1 ~ 12.0)
11.2 (3.1 ~ 12.0)
12.5 (3.3 ~ 14.0)
14.5 (3.5 ~ 15.5)
kCal/h
4300
6020
8600
9632
9632
10750
12470
kW
1.55
2.25
2.95
3.5
3.38
3.9
4.7
3.23
3.11
3.39
3.20
3.31
3.20
3.10
kW
6.2 (2.1 ~ 7.0)
8 (2.3 ~ 9.0)
11.0 (3.2 ~ 12.0)
12.3 (3.3 ~ 13.2)
12.3 (3.3 ~ 13.2)
13.8 (3.5 ~ 15.4)
16.0 (3.7 ~ 17.0)
kCal/h
5330
6880
9460
10578
10578
11868
13760
kW
1.9
2.5
3.14
3.78
3.72
4.25
4.85
3.26
3.20
3.50
3.25
3.31
3.25
3.30
Rotary
Rotary
Rotary
Rotary
Rotary
Rotary
Rotary
1
1
1
1
1
1
1
EER Heating Capacity Heating input COP Compressor type No. of compressors Water flow rate
m3/h
0.86
1.2
1.72
1.92
1.92
2.15
2.49
Max./min. water flow
m3/h
0.95/0.77
1.32/1.08
1.89/1.54
2.11/1.73
2.11/1.72
2.36/1.93
2.73/2.24
Max./min. water pressure
kPa
500/150
500/150
500/150
500/150
500/150
500/150
500/150
Refrigerant charge (R410A)
Kg
2.5
2.5
2.8
2.8
2.8
2.9
3.2
1
1
2
2
2
2
2
W
170
170
2x100
2x100
2x100
2x100
2x100
Dim. deep / wide / high
mm
354x990x966
354x990x966
Weight
Kg
81
81
110
110
110
111
111
dB (A)
58
58
59
59
59
60
60
Hydraulic connections
mm
DN25 (1")
DN25 (1")
DN32 (1 1/4")
DN32 (1 1/4")
DN32 (1 1/4")
DN32 (1 1/4")
DN32 (1 1/4")
Load loss evaporator
kPa
15
15
18
18
18
18
19
Axial fan Fan input power
Sound pressure
400x970x1327 400x970x1327 400x970x1327 400x970x1327 400x970x1327
Working Range
ºC
Cooling -5 ~ 46 / Heating -15 ~ 27
Supply water temperature
ºC
Cooling 4 ~ 20 / Heating 30 ~ 55
Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
294
Inspiration, Innovation, Evolution
DC R410A
INVERTER
!
DC
INVERTER
KIT
OUTDOOR
GENERAL CHARACTERISTICS Full DC Inverter Minichillers from 5 to 16 kW: Dry contacts for start/stop, cold/heat and alarm. Connection ports for additional water pump and optional wired controller.
+
COMPACT DESIGN AND EASY INSTALLATION
+
AUTO-RESTART FEATURE
+
CONTROLLER INCLUDED
+
COMPLETE HYDRAULIC KIT
INVERTER MINICHILLERS
• • • • •
On/Off Mode selector Temp. set Timer Diagnosis
KCCHT-03 Optional wired controller fitted with: • Touch control and LCD display. • Weekly timer. • Real-time clock
NEXUS CHILLERS
STANDARD CONTROLLER
295
CHILLERS RANGE FULL DC INVERTER CHILLERS
MODULAR FULL DC INVERTER CHILLERS TECHNICAL SPECIFICATIONS BASIC MODULES
MODEL Module 30 + Module 60 Power Cooling capacity Cooling input power
Heating input power
KEM-60 DNS3
KEM-90 DNS3
1+0
0+1
1+1
0+3
1+3
0+4
kW
27
55
82
110
137
165
192
220
23215
47300
70515
94600
117815
141900
165115
189200
kW
10.8
22
32.8
44
54.8
66
76.8
88
4.41
4.2
4.31
4.2
4.27
4.2
4.23
4.2
kW
31
61
92
122
153
183
214
244
kCal/h
26700
52500
79100
104900
131600
157400
184000
209800
kW
10.5
20.3
30.8
40.6
51.1
60.9
71.4
81.2
4.01
3.85
3.93
3.85
3.9
3.85
3.87
3.85
1
2
3
4
5
6
7
8
5
6
7
8
4%
4%
3%
3%
No. of compressors Compressor type
Double Twin Rotary DC
Number of cooling circuits %
1
2
3
4
10%
10%
4%
5%
Evaporator Evaporator pressure drop
1+2
380-415/3/40
kCal/h
SCOP
Minimum total capacity
KEM-120 KEM-150 KEM-180 KEM-210 KEM-240 DNS3 DNS3 DNS3 DNS3 DNS3 0+2
V-f-Hz
SEER Heating Capacity
KEM-30 DNS3
Plates kPa
60
80
80
80
80
80
80
80
Water flow
m3/h
5
9.8
14.55
19.6
24.35
29.4
34.15
39.2
Min./max. water flow
m3/h
3.5~5.7
7.5~12
11~17.7
15~24
18.5~29.7
22.5~36
26~41.7
30~48
Max. water pressure
MPa
1
1
1
1
1
1
1
1
2" (DN50)
-
-
-
-
-
-
Hydraulic connections
Inches (mm) 11/2" (DN40)
Capacitor
Blades
Number of condensers Air flow
m3/h
1
2
3
4
5
6
7
8
12500
24000
36500
48000
60500
72000
84500
96000
Control system included Refrigerant load (R410A)
KCCHT-04 MODBUS wired controller Kg
Number of axial ventilators
10.5
17
27.5
34
44.5
51
61.5
68
1
2
3
4
5
6
7
8
0.45
0.6 (x2)
1.65 (total)
2.4 (total)
2.85 (total)
3.6 (total)
4.05 (total)
4.8 (total)
Fan input power
kW
Dimensions (depth/width/height)
mm
Weight
Kg
300
480
780
960
1260
1440
1740
1920
Sound pressure
dB (A)
65.8
72.1
73
75.1
75.6
76.9
77.5
78.6
Working Range
ºC
Cooling -15~52 / Heating -15~30
Supply water temperature
ºC
Cooling 0~20 / Heating 25~55
1870/1000/ 2200/1035/ 2200/2035/ 2200/2070/ 2200/3070/ 2200/3105/ 1175 1325 1460 1460 1460 1460
Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
296
2200/4105/ 2200/4140/ 1460 1460
Inspiration, Innovation, Evolution
DC R410A
INVERTER
!
GENERAL CHARACTERISTICS
The Full DC Rotary Inverter compressor and Full DC brushless ventilators provide great stability and energy efficiency.
•
Full DC Inverter: The technology used in the Kaysun DC INVERTERS optimises consumption, adjusting with greater accuracy to the actual demand of the system.
•
Self-protection and self-diagnosis functions: Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.
•
Automatic control: A single control for all the models that form the system.
•
Dry contacts for start/stop, cold/ heat and alarm.
•
Condensation control.
The units are very compact and are designed to speed up maintenance. Up to 4 modules can be combined, reaching a capacity of 240 kW.
1
CONTROLLER ONLY FOR AUTOMATIC CONTROL
+
STANDARD MODBUS PROTOCOL GATE
KCCHT-04 MODBUS STANDARD CONTROLLER
NEXUS CHILLERS
Kaysun Full DC INVERTER CHILLERS are available in two types of module: a 30 kW module and a 60 kW module.
297
CHILLERS RANGE FULL DC INVERTER CHILLERS
FULL DC INVERTER CHILLERS WITH HYDRAULIC KIT TECHNICAL SPECIFICATIONS KEM-30 DNS3 KH
MODEL Power Cooling capacity Cooling input power
V-f-Hz
Heating input power
380-415/3/50
kW
27
55
kCal/h
23215
47300
kW
12
23.2
3.72
3.73
kW
31
61
kCal/h
26650
52450
kW
11.7
21.5
3.43
3.45
1
2
SEER Heating Capacity
SCOP Number of compressors Compressor type Minimum total capacity
KEM-60 DNS3 KH
Double Twin Rotary DC
%
10%
10%
Plates
Plates
kPa
60
80
Water flow
m³/h
5
9.8
Min./max. water flow
m³/h
3.8-6.4
8-13
Max. water pressure
Mpa Inches (mm) m³/h
1
1
1 1/2" (DN40)
2" (DN50)
12500
24000
Evaporator Evaporator pressure drop
Hydraulic connections Air flow Control system included Refrigerant load (R410A)
KCCHT-04 MODBUS
Kg
Number of axial ventilators
10.5
17
1
2
Fan input power
kW
0.45
0.6 x 2
Dimensions (depth/width/height)
mm
1870/1175/1000
2200/1325/1055
Weight
Kg
335
515
Sound pressure
dB
68
73
Pump pressure
mca / kPa
32 / 314
Pump flow rate
m³/h
At 27.1 mca, for a flow rate of 10 m3/h. (± 10%)
Expansion tank
L
Working Range
ºC
Cooling -15~52 / Heating -15~30
Supply water temperature
ºC
Cooling 0~20 / Heating 25~55
4.2
Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
298
12
Inspiration, Innovation, Evolution
DC R410A
INVERTER
!
KIT
GENERAL CHARACTERISTICS Kaysun Full DC INVERTER CHILLERS WITH HYDRAULIC KIT are available in two types of module: a 30 kW module and a 60 kW module.
•
Full DC Inverter: The technology used in the Kaysun DC INVERTERS optimises consumption, adjusting with greater accuracy to the actual demand of the system.
The Full DC Rotary Inverter compressor and Full DC brushless ventilators provide great stability and energy efficiency.
•
Self-protection and self-diagnosis functions: Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.
•
Automatic control: A single control for all the models that form the system.
•
Dry contacts for start/stop, cold/ heat and alarm.
•
Condensation control.
•
Full built-in hydraulic kit.
The units are very compact and are designed to speed up maintenance. These units include a built-in hydraulic kit.
1
CONTROLLER ONLY FOR AUTOMATIC CONTROL
+
STANDARD MODBUS PROTOCOL GATE
KCCHT-04 MODBUS STANDARD CONTROLLER
Venting system
Safety valve
Plate exchanger
Accumulator
HYDRAULIC KIT INCORPORATED
NEXUS CHILLERS
+
Water outlet
Water pump
Expansion tank
Liquid separator
299
CHILLERS RANGE FIXED SCROLL MODULAR CHILLERS
FIXED SCROLL MODULAR CHILLERS TECHNICAL SPECIFICATIONS MODEL Power Cooling capacity Cooling input
V-f-Hz
KEM-130 HN3
KEM-200 HN3
KEM-250 HN3
380/3/~50
380/3/~50
380/3/~50
kW
130
185
250
kCal/h
111800
159100
215000
kW
40.8
63
78.3
ESEER
3.13
3.07
3.06
kW
138
200
270
kCal/h
118680
172000
232200
kW
43
61
80
3.09
2.92
2.90
No. of compressors
4
6
8
No. of cooling cycles
4
6
4
25
17
25
Multitube
Multitube
Multitube
kPa
25
30
40
Water flow
m3/h
22.4
31.8
43
Min./max. water flow
m3/h
18.54/22.66
27.90/34.10
38.70/47.30
Max. water pressure
MPa
1
1
1
Inches (mm)
2 1/2" (DN65)
3" (DN80)
Heating Capacity Heating input COP
Min. total capacity
%
Evaporator Evaporator pressure drop
Hydraulic connections Capacitor Air flow
Aluminium blades m3/h
48000
Control system included Refrigerant charge (R410A)
4" (DN100) 33
72000
96000
KCCHT - 02 wired controller Kg
No. of axial fans
7x4
7x6
15x4
4
6
8
Fan input power
kW
0.865x4
0.865x6
0.7x8
Dimensions (depth/width/height)
mm
1685x2000x2080
2000x2850x2110
2000x3800x2130
Weight
Kg
1150
1730
2450
Sound pressure
dB (A)
70
74
74
Working Range
ºC
Cooling -10 ~ 46 / Heating -10 ~ 21
Supply water temperature
ºC
Cooling 0 ~ 17 / Heating 22 ~ 50
(*) Measurement at 1 m distance and 1.5 m height. Calculation conditions: Cooling: inlet/outlet cool water temperature: 12/7ºC, outdoor temperature 35ºC (dry bulb) Heating: inlet/outlet hot water temperature: 40/45ºC, outdoor temperature 7/6ºC (dry/wet bulb) Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
300
Inspiration, Innovation, Evolution
!
R410A
DIGITAL
GENERAL CHARACTERISTICS The KAYSUN NEXUS range continues to grow and completes its range of chillers with new fixed Scroll compressor modular units of 130, 200 and 250kW each, thereby providing great solutions designed to cover the needs of our customers. Equipped with 4, 6 and 8 compressors respectively, a "V"-type condensing coil and a multi-tube heat exchanger, these units provide a better capacity reach for the KAYSUN NEXUS range units. Just as versatile as lesser capacity units, these fixed Scroll compressor modular chillers can form modules of up to 4 units, arriving to capacities of 1000 kW.
•
Flexible combination: the connection between modules is as simple as connecting each of their inlet and outlet tubes.
•
Self-protection and self-diagnosis functions: Adjustment range for water outlet: from 0 to 17ºC for Cooling mode and from 22 to 50ºC for Heating mode.
•
Automatic control: A single control for all the models that form the system.
•
Dry contacts for start/stop, cold/ heat and alarm.
•
Condensation control.
•
Anti-icing function.
KCCHT-02 STANDARD CONTROLLER
x4
COMBINABLE UP TO 1000 kW
SINGLE BMS AND SOFTWARE NEXUS CHILLERS
INDIVIDUAL
KCCH-02 PS* *Includes weekly programmer
KCCHT-02
K01-LON KEM
K01- BACNET KEM* *Included only with KCCH-02 PS
KCCHT-02 MODBUS
301
CHILLERS RANGE HYDRAULIC KITS
EXTERNAL HYDRAULIC KITS TECHNICAL SPECIFICATIONS KHX-A-300
KHX-B-300
KHX-C-300
KHX-D-500
KHX-F-500
litres
300
300
300
500
500
bar
3
3
3
3
3
1
1
1
1
1
m3/h mca kW Inches V/f/Hz
11.18
16.4
22.4
27.6/31.8/33.6
38.8/43/44.8
17
17.7
14.4
18.8/17.3/16.6
18.4/17.7/17.3
1.1
1.5
1.5
2.2
3
2 1/2"
2 1/2"
2 1/2"
2 1/2"
3"
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
mm
1265x1504x1120
1265x1504x1120
1265x1504x1120
1265x1504x1120
1265x1504x1120
MODEL (WITH BUFFER TANK) + 1 PUMP Buffer tank capacity Pressure relief valve calibration No. of pumps Pump flow Pressure loss Power input Hydraulic connections Power Dimensions Height / Width / Depth Net weight Gross weight (with water)
Kg Kg Capacity litres Expansion Tank included* Calibration Pressure bar
MODEL (WITH BUFFER TANK) + DOUBLE PUMP Buffer tank capacity Pressure relief valve calibration No. of pumps Pump flow Pressure loss Power input Hydraulic connections Power Dimensions Height / Width / Depth Net weight Gross weight (with water)
188
188
213
341
488
488
713
841
25
25
25
25
25
1.5
1.5
1.5
1.5
1.5
KH2X-A-300
KH2X-B-300
KH2X-C-300
KH2X-D-500
KH2X-F-500
litres
300
300
300
500
500
bar
3
3
3
3
3
2
2
2
2
2
m3/h mca kW Inches V/f/Hz
11.18
16.4
22.4
27.6/31.8/33.6
38.8/43/44.8
17
17.7
14.4
18.8/17.3/16.6
18.4/17.7/17.3
1.1
1.5
1.5
2.2
3
2 1/2"
2 1/2"
2 1/2"
2 1/2"
3"
400/3/50
400/3/50
400/3/50
400/3/50
400/3/50
mm
1265x1504x1120
1265x1504x1120
1265x1504x1120
1265x1504x1120
1265x1504x1120
Kg Kg Capacity litres Expansion Tank included* Calibration Pressure bar
MODEL (WITHOUT BUFFER TANK) + 1 PUMP Buffer tank capacity Pressure relief valve calibration No. of pumps Pump flow Pressure loss Power input Hydraulic connections Power Dimensions Height / Width / Depth Net weight
186 486
litres bar
216
220
220
247
428
516
520
520
747
928
25
25
25
25
25
1.5
1.5
1.5
1.5
1.5
KHX-A
KHX-B
KHX-C
KHX-D
KHX-F
-
-
-
-
-
3
3
3
3
3
1
11.18 m3/h 17 mca 1.1 kW 2 1/2" Inches 400/3/50 V/f/Hz mm 1350x800x650 89 Kg 12 litres Expansion Tank Capacity included* 1.5 Calibration Pressure bar
1
1
1
1
16.4
22.4
27.6/31.8/33.6
38.8/43/44.8
17.7
14.4
18.8/17.3/16.6
18.4/17.7/17.3
1.5
1.5
2.2
3
2 1/2"
2 1/2"
2 1/2"
3"
400/3/50
400/3/50
400/3/50
400/3/50
1350x800x650
1350x800x650
1350x800x650
1350x1120x800
90
91
93
12
12
12
25
1.5
1.5
1.5
1.5
*Hydraulic kits include a standard expansion tank. In case that you want a different type of tank (see next page), lease inform the Sales Department.
302
153
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS
1. Inertia tank 2. Water pump 3. Expansion tank 5. On-off valve 6. Safety valve 7. Pressure gauge 8. Automatic venting system 10. Automatic filling unit 11. Electric panel
CHILLERS Compatible hydraulic kits*
CHILLERS Compatible hydraulic kits*
12. Check valve (version with 2 pumps only) 13. Drain 14. Anchor points (no. 4-6 holes M12/Ã&#x2DC;14) 15. Power Supply 16. Hoist points 17. Supply pipeline 18. Discharge pipeline
KEM-60 DNS3
KEM-120 DNS3
KEM-130 HN3
KEM-150 DNS3
KEM-180 DNS3
KHX-A
KHX-C
KHX-C
KHX-D
KHX-D
KHX-A-300
KHX-C-300
KHX-C-300
KHX-D-500
KHX-D-500
KH2X-A-300
KH2X-C-300
KH2X-C-300
KH2X-D-500
KH2X-D-500
KEM-200 HN3
KEM-210 DNS3
KEM-240 DNS3
KEM-250 HN3
KHX-D
KHX-F
KHX-F
KHX-F
KHX-D-500
KHX-F-500
KHX-F-500
KHX-F-500
KH2X-D-500
KH2X-F-500
KH2X-F-500
KH2X-F-500
(*)These application tables are for guidance purposes only. The final decision is to be made by the installer.
12 L Expansion Vessel
25 L Expansion Vessel
2 x 25 L Expansion Vessel 3 x 25 L Expansion Vessel
Capacity
litres
12
25
50
75
Calibration Pressure
bar
1.5
1.5
1.5
1.5
NEXUS CHILLERS
OPTIONAL EXPANSION VESSELS
303
CHILLERS RANGE ROTARY SCREW CHILLERS
AIR COOLED SCREW CHILLERS KAYSUN air cooled screw chillers are designed to meet all the requirements and standards related to reliability, energy efficiency and smart control. For this purpose, they are fitted with the best technologies available nowadays: Bitzer screw compressor, High precision electronic expansion valves, condensers optimised for maximum efficiency and heat exchange, high performance multitubular evaporator, and so on.
A COST EFFECTIVE TOOL FOR YOUR HOME
COST-EFFECTIVE OPERATION
• High reliability equipment.
• High energy efficiency.
• High quality components: Bitzer, Danfoss, Schneider Electric, etc.
• Based on AHRI 550/590 standard; the unit works partially loaded 99% of its working hours.
• All units have undergone extensive testing to ensure perfect operation, in facilities that are a worldwide standard.
• Optimized performance on partial loads between 50%~75%. • Easy service, low maintenance costs.
• Easy and fast installation process.
QUIET OPERATION • Impellers designed to reduce noise. • Smart control logic that balances fan’s performance and operation. • Super low noise model (optional).
ENVIRONMENTAL RESPONSIBILITY • Its high efficiency also means less consumption, which reduces gas emissions. • R-134A refrigerant, ozone-depleting potential free.
SMART CONTROL • Controlled by integrated microprocessor with touch screen. • Gateway to communication protocols and BMS. • Own software for selecting and managing the chiller.
INVERTED "M"-SHAPED AIR CONDENSER
M
KAYSUN screw chillers are the ideal choice for schools, hospitals, shopping malls, office buildings, factories and large installations in general.
304
Inspiration, Innovation, Evolution
WATER COOLED SCREW CHILLERS KAYSUN water cooled screw chillers include a flooded multitubular evaporator and a high efficiency multitubular condenser. They are also equipped with high-precision electronic expansion valves and Bitzer semi-hermetic twin-screw compressors, which means maximum efficiency both at full load and partial loads. Each chiller is fully tested before delivery.
A COST EFFECTIVE TOOL FOR YOUR HOME
ENVIRONMENTAL RESPONSIBILITY
• High reliability equipment.
• Its high efficiency also means less consumption, which reduces gas emissions.
• The best components, technologies such as triple stage oil separation to ensure perfect lubrication of the compressor. • All units have undergone extensive testing to ensure perfect operation, in facilities that are a worldwide standard. • Easy and fas installation process.
• R-134A refrigerant, ozone-depleting potential free.
SMART CONTROL • Controlled by integrated microprocessor with touch screen. • Gateway to communication protocols and BMS.
COST-EFFECTIVE OPERATION • High energy efficiency.
• Own software for selecting and managing the chiller.
• Easy service, low maintenance costs.
NEXUS CHILLERS
1. Input 2. Motor 3. Screw 4. Poppet valve 5. Output 6. Oil separator 7. Bearing 8. Electric resistance of the oil pan 9. Oil filter
KAYSUN water condensed screw chillers are the ideal choice for shopping centres, hospitals, factories, and large air conditioning and comfort installations. Its applications also extend to the plastics industry, the plating industry, food processing, the chemical industry and other processing facilities that require large amounts of cold water.
305
CHILLERS RANGE ROTARY SCREW CHILLERS
CENTRIFUGAL CHILLERS CHILLERS RANGE KAYSUN introduces its most powerful range of chillers, thanks to the addition of centrifugal compressors.
â&#x20AC;&#x153;THE HIGHEST POWER AT YOUR SERVICE"
They are available in three different options according on their efficiency. From standard units to high-efficiency and, eventually, super high-efficiency units, with 7.11 EER. All our units use R134a, an environmentally friendly refrigerant with a low GWP (Global Warming Potential), which results in maximum performance.
STANDARD EFFICIENCY The Standard Efficiency range units are available with two different type of configurations. One consists of a power range between 1.58MW to 4.22MW, a single compression stage and a flooded multi-tube type evaporator. The second configuration consists of two stages and a full falling film multitubular evaporator, which results in higher cooling power, from 4.57 MW to 7.73 MW. All these units provide between 5.3 and 5.7 EER.
WHAT IS "FULL FALLING FILM"? It is the latest in refrigerant savings systems. This new concept allows using 40% less refrigerant than the traditional flooded multitube type evaporator, and increases the energy exchange rate between 3% and 8%.
ED
T EN
T PA
HOW DOES IT WORK? The refrigerant falls in a liquid state in the form of rain between the tubes. As it falls through several levels, the refrigerant evaporates.
40% reduction in refrigerant charge
Flooded type The falling film reaches around 40% of the refrigerant charge compared with the flooded type.
306
Full falling film Almost 0% of liquid level
This way, only a small percentage of refrigerant reaches the bottom of the evaporator.
Inspiration, Innovation, Evolution
HIGH EFFICIENCY High efficiency chillers are one-step ahead. They are divided into two different configurations. One consists of a onestage centrifugal compressor and a flooded evaporator, which results in a power range from 2.46MW to 4.22MW. The second configuration consists of a two-stage compressor and an evaporator including the Full Falling Film system. High Efficiency units provide from 5.6 to 6.8 EER.
CONTROL PANEL All centrifugal units are fitted with an easy to access control panel. They also include a 10.4 inches LCD touch screen to display graphic views of the chiller. The screen is easy to access. It communicates with PCs, starts and stops the unit remotely and provides more than 30 protection functions that can be checked in the 10 last failure reports.
SUPER HIGH EFFICIENCY The Kaysun Super High Efficiency RANGE, include units with 7.11 EER, which turns them into the most efficient product in the market, considering their performance. These units can reach up to 7.73 MW with a two-stage centrifugal compressor fitted with a multi-tube evaporator including the new full falling film system.
GUARANTEE OF SUCCESS
NEXUS CHILLERS
IN ORDER TO ensure the perfect operation of its high-capacity chillers, Kaysun performs tests on all of its units. This way, the company is able to guarantee that its products will comply with all the established requirements.
307
CHILLERS RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
GADIS SUPERMARKET COMMERCIAL BUILDING Location: Oleiros - Coruña Initial situation: New construction Units installed: Nexus Capacity: 195 kW
308
NEXUS CHILLERS
Inspiration, Innovation, Evolution
309
CHILLERS RANGE KEY INSTALLATIONS
THE NEXUS RANGE REPRESENTS KAYSUN'S COMMITMENT TO ENVIRONMENT. THANKS TO ITS WIDE RANGE OF DIMENSIONS AND CAPACITIES, NEXUS CHILLERS ADAPT TO EVERY TYPE OF SPACE. HOTELS, OFFICES AND BUSINESS CENTRES CHOOSE THIS RANGE AS THEIR ALLY IN THE AIR-CONDITIONING OF THEIR INSTALLATIONS.
FOSTERS HOLLYWOOD RESTAURANT
Location: Gijón Initial situation: New construction Units installed: Nexus, Zen Capacity: 90 kW
OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN NEXUS HOTELS Al-Mirab Hotel (Córdoba), Calabera Hotel (Huelva), Marina Luz Hotel (Palma de Mallorca), Ambos Mundos Hotel (Palma de Mallorca), Mac Hotels (Palma de Mallorca), Paraiso Hotel (Málaga), Gran Palladium Resort (Ibiza), Ruta Jacobea Hotel (Santiago Compostela), Alcotan Hotel (San Pedro de Alcantara), Orly Hotel (Camponaraya, León). PUBLIC BUILDINGS Baza City Council (Granada), Caracoles Building -
310
Chamartin Railway Station (Madrid), 091 Emergencies Headquarters (Málaga), Madrid Underground Headquarters (Madrid), Barakaldo City Council (Bizkaia), T2 Terminal AENA Airport (Barcelona). SCHOOLS AND UNIVERSITIES San Luis School (Menorca), Camino de Gelves Nursery School (Seville), María de la Salud State School (Majorca) HOSPITALS, CLINICS AND HEALTH CENTRES San Juan de Dios Clinic (Málaga) Santa Elena Clinic (Málaga), Old
People's Home (Fuente de Piedra), Rincón Clinic (Béjar), Old People's Home (Ronda). RESIDENCES Alpe Buildings (Tarragona) .LEISURE CENTRES Xesc Forteza Theater (Palma de Mallorca), School of Music (Cádiz), The Royal Calvary (Seville), Ribadeo Auditorium (Lugo), GAS Natural Headquarters (Rubí). BUSINESS CENTRES AND OFFICES Aerospace Engineering Group (Seville), Banca March (Palma de Mallorca), Health Department
Headquarters of the Andalusia Autonomous Government (Cádiz), Hilaturas Ferre (Alicante), Leti Laboratories (Barcelona), Casa del Libro Book Stores (Barcelona), Prenatal (Almeria), Zara HOME (Valencia), Stradivarius (Gerona, A Coruña), Imegasa Paper and Pulp Mill (Mugardos, A Coruña), Pharmaceutical Cooperative (Santiago Compostela), Wine Cooperative (Cacabelos, Leon).
Inspiration, Innovation, Evolution
SPORTS COMPLEX
SCHOOL OF MUSIC
ESADE
LEISURE CENTRE
PUBLIC BUILDING
UNIVERSITY
Location: Andorra Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 600 kW
Location: Mallorca Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 200 kW
Location: Barcelona Initial situation: Renovation Units installed: Kem Modular Digital Scroll Capacity: 195 kW
VOLKSWAGEN
ANDALUCIA PRINCESS
ZARA
BUSINESS CENTRE
HOTEL
COMMERCIAL BUILDING
Location: Barcelona Initial situation: Replacement Units installed: Nexus Capacity: 200 kW
Location: Malaga Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 700 kW
Location: Girona Initial situation: New construction Units installed: Kem Modular Digital Scroll Capacity: 195 kW
MATUTES - FIESTA HOTELS
GRAND PALLADIUM
MUSEUM OF ENTHNOGRAPHY
HOTEL
HOTEL
CULTURAL CENTRE
Location: Ibiza Initial situation: Renovation Units installed: Nexus Capacity: 200 kW
Location: Ibiza Initial situation: Renovation Units installed: Minichillers Capacity: 251 kW
Location: Zamora Initial situation: New construction Units installed: Nexus Capacity: 95 kW
CORDEX TEXTILE COMPANY
NEXUS CHILLERS
BIÃ&#x2C6;RE ARTISANALE SARLAT BREWERY
Location: Vezac y Sarlat la Caneda (France) Initial situation: Renovation Units installed: Digital Scroll Capacity: 95 kW
Location: Esmoriz (Portugal). Initial situation: New construction Units installed: KEM200HN3 + KEM130HN3 Capacity: 315 kW
311
FANCOILS WATER TERMINAL UNITS PRODUCT RANGE
INTRODUCTION TO THE PRODUCT RANGE......................................314 UNITS HIGH WALL .................................................KFC-AY.....................318 CEILING & FLOOR ........................................KFC-S(E)...................320 CASSETTES 600x600 .................................KFC-CI.......................322 CASSETTES .................................................KFC-CIS.....................324 DUCTS ..........................................................KFC-PD......................326 HIGH PRESSURE DUCTS ............................KFC-PDH...................328 KEY INSTALLATIONS..........................................................................330
FANCOILS FANCOILS FANCOILS
WATER TERMINAL UNITS PRODUCT RANGE
WATER TERMINAL UNITS PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
FANCOILS
WATER TERMINAL UNITS RANGE
Introducing KAYSUN Fan Coils range, a series of water terminal units that include DC inverter fans in practically all its range. These units are the perfect complement to the Nexus range of water chillers. The indoor units of this range have different type of models, such as wall-mounted, ceiling & floor, cassette 600x600, cassette 840x840, ducts and high static pressure ducts. KAYSUN has a perfect solution for every need.
“THE COMFORT OF WATER”
INDOOR UNITS AVAILABLE WITH 2 AND 4 PIPES The Cassette 600x600 and Cassette 840x840 units and low profile duct unit are available with 2 and 4 pipes configurations. The four-pipes configurations allow units to work in Cooling mode and in Heating mode simultaneously and separately in the same installation. Four-pipes coils are fitted with two rows to work in Cooling mode, and with one row to work in Heating mode. The Duct and Cassette units include a standard extended drain pan. The Fancoil Cassette and Duct type units have an optional L-shaped pipework kit for easy installation.
CONTROL KAYSUN Fan Coils have a wide range of controls, whether individual wireless, single wired, centralised or gateways for integration into building management systems. Aesthetically and functionally, KAYSUN offers everything from the classic conventional thermostat with sensor, temperature selection wheel and two switches (heat/ off/cold and 3 speeds), to the most advanced tactile controls.
THERMOSTAT
ADVANCED CONTROL
All KAYSUN Fan Coils are compatible with these controls as standard, except for Duct Fan Coils and Ceiling & Floor Fan Coils, which have basic controls and an interface (with their 2 or 4-tube version) to be managed by the most advanced controls. INTERFACE TO CONTROL
314
Inspiration, Innovation, Evolution
POWER RANGE HIGH WALL 2 PIPES
(Page 318) 490
680
980
KFC-AY-2T-250D
KFC-AY-2T-400D
KFC-AY-2T-600D
FLOW RATE (m3/h)
CEILING & FLOOR 2 PIPES
(Page 320)
370
600
750
1500
KFC-S-2T-250D
KFC-S-2T-400D
KFC-S-2T-500D
KFC-S-2T-900D
KFC-SE-2T-400D
KFC-SE-2T-500D
KFC-SE-2T-900D
FLOW RATE (m3/h)
EXPOSED
CONCEALED KFC-SE-2T-250D
CASSETTES 600x600
(Page 322)
FLOW RATE (m /h) 3
540
780
KFC-CI-2T-300D
KFC-CI-2T-500D
KFC-CI-4T-300D
KFC-CI-4T-500D
2 PIPES
4 PIPES
CASSETTES
(Page 324) 1175
FLOW RATE (m3/h)
1230
1530
1580
1870
2 PIPES KFC-CIS-2T-600D
KFC-CIS-2T-750D
KFC-CIS-2T-950D
KFC-CIS-2T-1200D
KFC-CIS-2T-1500D
4 PIPES KFC-CIS-4T-600D
DUCTS
KFC-CIS-4T-950D
KFC-CIS-4T-1500D
(Page 326) 340
600
730
1020
1450
KFC-PD-2T-200-1
KFC-PD-2T-300D
KFC-PD-2T-400D
KFC-PD-2T-600D
KFC-PD-2T-800D
340
510
680
1020
1360
KFC-PD-4T-200-1
KFC-PD-4T-300-1
KFC-PD-4T-400-1
KFC-PD-4T-600-1
KFC-PD-4T-800-1
FLOW RATE (m3/h)
2 PIPES
FLOW RATE (m3/h)
4 PIPES
FLOW RATE (m3/h)
1700
(Page 328)
2000
KFC-PDH-2T-1000
2380
KFC-PDH-2T-1400
2550
3060
3740
KFC-PDH-2T-1800
KFC-PDH-2T-2200 FANCOILS FANCOILS
HIGH STATIC PRESSURE DUCTS 2 PIPES
Kaysun Fan Coils range will soon be granted with the Eurovent Certification.
315
WATER TERMINAL UNITS PRODUCT RANGE INTRODUCTION TO THE RANGE OF PRODUCTS
316
Inspiration, Innovation, Evolution
UNITS
FANCOILS FANCOILS
TECHNICAL SPECIFICATIONS
317
WATER TERMINAL UNITS PRODUCT RANGE WALL-MOUNTED
WALL-MOUNTED TECHNICAL SPECIFICATIONS 2 PIPES KFC-AY-2T-250D
KFC-AY-2T-400D
KFC-AY-2T-600D
kW
2.59 (2.39 - 2.7)
3.3 (2.88 - 3.81)
4.26 (3.79 - 4.87)
Kcal/h
2230 (2060 - 2323)
2840 (2480 - 3280)
3660 (3260 - 4190)
1.85 (2.03 - 2.15)
2.71(2.31 - 3.18)
3.56 (3.1 - 4.11)
kW
3.03 (2.63-3.29)
4.33 (3.77 - 5.08)
5.57 (4.77 - 6.31)
Kcal/h
2610 (2260 - 2830)
3720 (3240 - 4370)
4790 (4100 - 5430)
W
11 (10 - 13)
22 (15 - 34)
26 (18 - 38)
MODEL Capacity (min.-max.) Total rated cooling
Rated sensitive cooling (min.-max.) Rated heating capacity (min.- max.)
Power consumption
Rated cooling (min.-max.)
W
10 (8 - 12)
20 (14 - 31)
23 (16 - 33)
m3/h
492/454/400
825/689/590
979/849/717
H
mm
290
290
315
Width
mm
915
915
1072
Depth
mm
230
230
230
Kg
12.7
12.7
14.9
Sound pressure (low/medium/high)
dB (A)
27/30/32
35/39/45
35/40/44
Hydraulic connections Ø
Inches
Rated heating (min.-max.)
Air flow (high/medium/low) Unit dimensions N.W. of the unit
Evaporator pressure drop
Rated cooling (min. - max.)
kPa
28.63 (25.36 - 31.61)
41.23 (33.02 - 56.75)
39.47 (33.66 - 50.68)
Rated heating (min. - max.)
kPa
30.25 (26.53 - 37.49)
37.88 (30.34 - 61.94)
36.3 (30.3 - 51.65)
m3/h
0.46 (0.42 - 0.48)
0.57 (0.51 - 0.67)
0.72 (0.65 - 0.85)
Rated eater flow (min. - max.) Power supply
V/ph/Hz
*Calculation conditions: Cooling: Water inlet/outlet temperature 7/12ºC; Indoor temperature 27ºC dry bulb, 19ºC wet bulb; Fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
318
3/4
220-240/1/50
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS Wall-mounted units with a compact and elegant design. They include a translucent LED display that provides it with a modern design by using the most advanced technology in the market.
•
2 Pipes.
•
Standard 3-way on/off valve included.
•
DC Inverter fan motor
+
COMPATIBLE WITH ALL THE KAYSUN CONTROLLERS RANGE.
+
DC INVERTER FAN
KID-02 S *Recommended Kaysun controller.
COMPATIBLE CONTROLLERS
KID-02 S KI-02.3 S
INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR
CENTRALISED KCCT-64 I (B) KCC-64 WEB
MANAGEMENT SYSTEM
BMS INTEGRATION SYSTEMS
KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET
WIFI CONTROL K01-WIFI
FANCOILS FANCOILS
INDIVIDUAL WIRELESS
For further information, please see our Controllers range.
319
WATER TERMINAL UNITS PRODUCT RANGE FLOOR / CEILING
CEILING & FLOOR TECHNICAL SPECIFICATIONS 2 PIPES EXPOSED MODEL
Rated total cooling
Capacity (min.- max.)
kW Kcal/h
Rated sensitive cooling (min.-max.) Rated heating capacity (min.- max.)
Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit Width dimensions Depth N.W. of the unit Sound pressure (low/medium/high) Hydraulic connections Ø Rated cooling (min. - max.) Evaporator pressure drop Rated heating (min. - max.) Rated eater flow (min. - max.) Power consumption
Power supply
kW Kcal/h W W m3/h mm mm mm Kg dB (A) Inches kPa kPa m3/h V/ph/ Hz
KFC-S-2T-250D
KFC-S-2T-400D
KFC-S-2T-500D
KFC-S-2T-900D
1.52 (1.07 - 2.07) 1310 (920 - 1780) 1.07 (0.72 - 1.52) 2.07 (1.42 - 2.78) 1780 (1220 -2390) 10 (7 - 17) 11 (7 - 18) 369/272/196 592 800 220 24.4 22/31/39
2.63 (2.12 - 3.25) 2260 (1820 - 2790) 1.93 (1.5 - 2.48) 3.34 (2.63 - 4.37) 2870 (2260 - 3760) 16 (10 - 30) 15 (9 - 30) 604/448/343 592 1000 220 28.2 31/37/44
3.73 (2.8 - 4.82) 3200 (2410 - 4140) 2.62 (1.9 - 3.51) 4.65 (3.44 - 6.17) 4000 (2960 - 5310) 16 (10 - 31) 16 (10 - 31) 748/555/398 592 1200 220 34.2 27/35/42
5.67 (4.72 - 7.17) 4875 (4060 - 6170) 4.47 (3.6 - 5.92) 7.48 (5.94 - 9.96) 6430 (5110 - 8560) 38 (21 - 103) 38 (21 - 106) 1509/1054/806 592 1500 220 40 35/42/51
6.7 (3.8 - 11.13) 5.22 (3 - 11.99) 0.27 (0.20 - 0.36)
16.38 (11.14 - 23.2) 13.86 (9.1 - 22.9) 0.49 (0.38 - 0.59)
17.1 (10.74 - 27.32) 14.1 (9 - 27.46) 0.65 (0.51 - 0.85)
18.96 (14.04 - 30.94) 16.71 (12.38 - 34.9) 0.99 (0.84 - 1.29)
3/4
220-240/1/50
2 PIPES CONCEALED MODEL
Rated total cooling
Capacity (min.- max.) Rated sensitive cooling (min.-max.) Rated heating capacity (min.- max.)
Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit Width dimensions Depth N.W. of the unit Sound pressure (low/medium/high) Hydraulic connections Ø Rated cooling (min. - max.) Evaporator pressure drop Rated heating (min. - max.) Rated eater flow (min. - max.) Power consumption
Power supply
kW Kcal/h kW Kcal/h W W m3/h mm mm mm Kg dB (A) Inches kPa kPa m3/h V/ph/ Hz
KFC-SE-2T-250D
KFC-SE-2T-400D
KFC-SE-2T-500D
KFC-SE-2T-900D
1.52 (1.07 - 2.07) 1310 (920 - 1780) 1.07 (0.72 - 1.52) 2.07 (1.42 - 2.78) 1780 (1220 -2390) 10 (7 - 17) 11 (7 - 18) 369/272/196 545 550 212 17 22/31/39
2.63 (2.12 - 3.25) 2260 (1820 - 2790) 1.93 (1.5 - 2.48) 3.34 (2.63 - 4.37) 2870 (2260 - 3760) 16 (10 - 30) 15 (9 - 30) 604/448/343 545 750 212 20 31/37/44
3.73 (2.8 - 4.82) 3200 (2410 - 4140) 2.62 (1.9 - 3.51) 4.65 (3.44 - 6.17) 4000 (2960 - 5310) 16 (10 - 31) 16 (10 - 31) 748/555/398 545 950 212 25 27/35/42
5.67 (4.72 - 7.17) 4875 (4060 - 6170) 4.47 (3.6 - 5.92) 7.48 (5.94 - 9.96) 6430 (5110 - 8560) 38 (21 - 103) 38 (21 - 106) 1509/1054/806 545 1250 212 32 35/42/51
6.7 (3.8 - 11.13) 5.22 (3 - 11.99) 0.27 (0.20 - 0.36)
16.38 (11.14 - 23.2) 13.86 (9.1 - 22.9) 0.49 (0.38 - 0.49)
17.1 (10.74 - 27.32) 14.1 (9 - 27.46) 0.65 (0.51 - 0.85)
18.96 (14.04 - 30.94) 16.71 (12.38 - 34.9) 0.99 (0.84 - 1.29)
3/4
*Calculation conditions: Cooling: Water inlet/outlet temperature 7/12ºC; Indoor temperature 27ºC dry bulb, 19ºC wet bulb; Fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
320
220-240/1/50
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS This unit is especially designed to save space. Due to its reduced depth, it is the perfect solution that adapts to every type of installation, from wall-mounted to floor standing, whether totally or partially recessed, adapting perfectly to the aesthetics of the environment.
•
2 pipes
•
DC Inverter fan motor
*It can be integrated in the body of the concealed FLOOR / CEILING type units
+
DC INVERTER FAN
+
HORIZONTAL/VERTICAL INSTALLATION
COMPATIBLE WITH
, Thermostat KC-FC-2T
or Thermostat KC-FCD-2T
+
COMPATIBLE WITH
Interface to control
Thermostat KC-FCS-2T
CHOOSE YOUR
CONTROLLER
CONTROLLERS COMPATIBLE WITH THE INTERFACE TO KAYSUN CONTROLLER INDIVIDUAL WIRELESS
INDIVIDUAL WIRED
KID-02 S KI-02.3 S
KC-01 S KC-02.1 H KCT-02.1 SR
CENTRALISED KCCT-64 I (B) KCC-64 WEB
MANAGEMENT SYSTEM
BMS INTEGRATION SYSTEMS
KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET
WIFI CONTROL K01-WIFI
For further information, please see our Controllers range.
COMPATIBLE ACCESSORIES
IT INCLUDES:
IT INCLUDES:
• 3 BUTTONS
KC-FC-2T
KC-FCD-2T
ON/OFF HOT/COLD 3 SPEEDS
• DIRECTIONAL BUTTONS FOR INCREASING/ REDUCING TEMPERATURE • TIMER
• 3 BUTTONS
KC-FCS-2T *Kaysun thermostat recommended for concealed units
ON/OFF HOT/COLD 3 SPEEDS
• DIRECTIONAL BUTTONS FOR INCREASING/ REDUCING TEMPERATURE
K01-FC-2T
KV3-FC 3/4
KACT-0
ACCESSORIES DESCRIPTION
MODEL
DESCRIPTION
Pipework kit for CEILING & FLOOR 2T valve
K01-FC-2T
KAYSUN control interface
KC-FC-2T
Thermostat 2T
KV3-FC 3/4
3-way valve 3/4
KC-FCD-2T
Thermostat with display
KACT-O
On/off actuator
KC-FCS-2T
Thermostat with display (recommended for CONCEALED ducts)
FANCOILS FANCOILS
MODEL KIT TUB FC S(E)2T-1
321
WATER TERMINAL UNITS PRODUCT RANGE CASSETTES
CASSETTES 600x600 TECHNICAL SPECIFICATIONS 2 PIPES MODEL Capacity (min.-max.) Rated total cooling
kW Kcal/h
Rated sensitive cooling (min.-max.) Rated heating (min.-max.)
Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit dimensions Width Depth N.W. of the unit H Panel dimensions Width Depth Panel net weight Sound pressure (low/medium/high) Hydraulic connections Ø Evaporator pressure Rated cooling (min. - max.) drop Rated heating (min. - max.) Rated eater flow (min. - max.) Power supply Power consumption
kW Kcal/h W W m3/h mm mm mm Kg mm mm mm Kg dB (A) Inches kPa kPa m3/h V/ph/Hz
KFC-CI-2T-300D
KFC-CI-2T-500D
2.53 (2 - 2.98) 2180 (1720 - 2560) 2.08 (1.59 - 2.49) 3.35 (2.61 - 4.01) 2880 (2240 - 3450) 9 (5 - 15) 9 (5 - 14) 535/429/322 261 575 575 16.5 50 647 647 2.5 27/33/39
3.48 (3.01 - 4.2) 2990 (2590 - 3610) 2.74 (2.31 - 3.45) 4.69 (3.84 - 5.76) 4030 (3300 - 4950) 28 (21 - 43) 18 (11 - 23) 781/611/494 261 575 575 16.5 50 647 647 2.5 32/38/43
3/4
7 (5 - 10) 6 (3.8 - 8.2) 0.45 (0.35 - 0.53)
8.62 (7.4 - 12.32) 6.5 (5.41 - 11.41) 0.61 (0.54 - 0.75) 220-240/1/50
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
4 PIPES MODEL Capacity (min.-max.) Rated total cooling
Rated sensitive cooling (min.-max.) Rated heating (min.-max.)
Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit dimensions Width Depth N.W. of the unit H Panel dimensions Width Depth Panel net weight Sound pressure (low/medium/high) Cooling operation Hydraulic connections Ø Heating Evaporator pressure Rated cooling (min. - max.) drop Rated heating (min. - max.) Cooling operation Rated eater flow (min. - max.) Heating Power supply Power consumption
kW Kcal/h kW Kcal/h W W m3/h mm mm mm Kg mm mm mm Kg dB (A) Inches Inches kPa kPa m3/h m3/h V/ph/Hz
KFC-CI-4T-300D
KFC-CI-4T-500D
2.08 (1.65 - 2.4) 1790 (1420 - 2060) 1.78 (1.39 - 2.08) 3.25 (2.55 - 3.85) 2790 (2190 - 3310) 9 (5 - 14) 9 (5 - 15) 536/429/321 261 575 575 16.7 50 647 647 2.5 27/33/39
2.62 (2.3 - 3.05) 2250 (1980 - 2620) 2.21 (1.9 - 2.61) 4.12 (3.5 - 4.9) 3540 (3010 - 4210) 17 (11 - 32) 17 (10 - 32) 731/572/462 261 575 575 16.7 50 647 647 2.5 31/39/44
13.5 (9.3 - 17.4) 21.7 (14.3 - 29.8) 0.36 (0.29 - 0.42) 0.36/0.30/0.24
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
322
3/4 1/2
220-240/1/50
13.1 (10.3 - 16.8) 25.9 (19 - 36.1) 0.47 (0.40 - 0.54) 0.46/0.38/0.33
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS With its new 360º panel, the Art Flux cassette provides even, fast and far-reaching air-conditioning control, without leaving dead zones. Since the main unit and panel are compact (570mm width and depth), they are lighter and require less space and equipment to be installed. They can be completely integrated into any space, including shallow ceilings, without sticking out.
•
•
Fresh air supply and air blow towards adjacent rooms.
•
Standard extended drainage pan.
•
Optional pipework kit.
•
Optional three-way valve.
•
Optional on/off valve driver.
•
DC Inverter fan motor.
Condensation pump.
+
DC INVERTER FAN
+
SAME PANEL AS VRF - ART FLUX 360º UNITS
CASSETTE 600x600 2 PIPES
KID-02 S *Kaysun controller recommended
CASSETTE 600x600 4 PIPES
COMPATIBLE CONTROLLERS INDIVIDUAL WIRELESS KID-02 S KI-02.3 S
INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR
CENTRALISED KCCT-64 I (B) KCC-64 WEB
MANAGEMENT SYSTEM
BMS INTEGRATION SYSTEMS
KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET
WIFI CONTROL K01-WIFI
For further information, please see our Controllers range.
COMPATIBLE ACCESSORIES 2 PIPES
KIT TUB FC CI-2T
KV3-FC 3/4
COMPATIBLE ACCESSORIES 4 PIPES
KACT-0
TUB FC CI-4T KIT
KV3-FC 1/2
KACT-0
KV3-FC 3/4
ACCESSORIES FOR 2 PIPES UNITS DESCRIPTION
MODEL
DESCRIPTION
KIT TUB FC CI-2T
Pipework kit for Cassette 600x600 units’ valve
TUB FC CI-4T KIT
Pipework kit for Cassette 600x600 units' valve
KV3-FC 3/4
3-way valve 3/4
KV3-FC 1/2
3-way valve 1/2 (hot water)
KACT-O
on/off Actuator
KV3-FC 3/4
3-way valve 3/4 (cool water)
KACT-O*
on/off Actuator
FANCOILS FANCOILS
MODEL
ACCESSORIES FOR 4 PIPES UNITS
*You will need 2 actuators for your 4-Ducts Fan Coil.
323
WATER TERMINAL UNITS PRODUCT RANGE CASSETTES
CASSETTES TECHNICAL SPECIFICATIONS 2 PIPES KFC-CIS-2T-600D KFC-CIS-2T-750D KFC-CIS-2T-950D KFC-CIS-2T-1200DKFC-CIS-2T-1500D
MODEL
kW 5.3 (4.4 - 5.93) 5.45 (4.6 - 6.12) 6.84 (6.35 - 7.84) 7.12 (6.67 - 7.87) 8.82 (7.48 - 11.19) Capacity (min.- max.) Kcal/h 4560 (3780 - 5100) 4690 (3960 - 5260) 5880 (5460 - 6740) 6120 (5740 - 6770) 7580 (6430 - 9620) Rated total Rated sensitive cooling (min.-max.) 4.34 (3.52 - 5) 4.51 (3.72 - 5.18) 5.6 (5.13 - 6.63) 5.95 (5.5 - 6.68) 7.03 (5.97 - 9.04) cooling kW 7.37 (6.06 - 8.42) 7.49 (6.27 - 8.62) 9.24 (8.49 - 10.86) 9.84 (9.16 - 10.92) 11.73 (10.07 - 14.92) Rated heating (min.-max.) Kcal/h 6340 (5210 - 7240) 6440 (5390 - 7410) 7950 (7300 - 9340) 8460 (7880 - 9390) 10090 (8660 - 12830) Rated cooling (min.-max.) W 27 (17 - 41) 31 (20 - 49) 42 (34 - 75) 59 (45 - 85) 58 (39 - 126) Power consumption Rated heating (min.-max.) W 28 (17 - 42) 31 (19 - 49) 42 (33 - 76) 58 (45 - 85) 58 (39 - 127) Air flow (high/medium/low) m3/h 1175/987/768 1229/1020/810 1530/1224/1101 1581/1371/1236 1871/1415/1198 H mm 230 230 300 300 300 Unit Width mm 840 840 840 840 840 dimensions Depth mm 840 840 840 840 840 N.W. of the unit Kg 23 23 27 27 29.5 H mm 45 45 45 45 45 Panel Width mm 950 950 950 950 950 dimensions Depth mm 950 950 950 950 950 Panel net weight Kg 6 6 6 6 6 Sound pressure (low/medium/high) dB (A) 33/39/43 34/40/44 39/42/46 41/44/48 39/43/49 Hydraulic connections Ø Inches 3/4 Rated cooling (min. - max.) kPa 15.4 (11 - 19.2) 17.4 (12.4 - 21.3) 17 (14.1 - 22) 18.1 (16.3 - 22.3) 22.7 (16.4 - 36.6) Evaporator pressure drop Rated heating (min. - max.) kPa 12.7 (8.6 - 16.9) 14.8 (10.6 - 19.1) 15.2 (12.6 - 19.9) 16.2 (14.7 - 20) 21.3 (15 - 34.3) Rated eater flow (min. - max.) 0.92 (0.77 - 1.05) 0.96 (0.81 - 1.10) 1.24 (1.13 - 1.43) 1.28 (1.22 - 1.44) 1.53 (1.28 - 1.96) m3/h Power supply V/ph/Hz 220-240/1/50 *Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
4 PIPES MODEL Capacity (min.-max.) Rated total cooling
Rated sensitive cooling (min.-max.) Rated heating (min.-max.)
Rated cooling (min.-max.) Rated heating (min.-max.) Air flow (high/medium/low) H Unit dimensions Width Depth N.W. of the unit H Panel dimensions Width Depth Panel net weight Sound pressure (low/medium/high) Cooling operation Hydraulic connections Ø Heating Evaporator pressure Rated cooling (min. - max.) drop Rated heating (min. - max.) Cooling operation Rated eater flow (min. - max.) Heating Power supply Power consumption
kW Kcal/h kW Kcal/h W W m3/h mm mm mm Kg mm mm mm Kg dB (A) Inches Inches kPa kPa m3/h m3/h V/ph/Hz
KFC-CIS-4T-600D
KFC-CIS-4T-950D
KFC-CIS-4T-1500D
4.81 (4 - 5.36) 4140 (3440 - 4610) 4.17 (3.42 - 4.66) 6.88 (5.83 - 7.66) 5920 (5010 - 6590) 33 (19 - 50) 33 (19 - 50) 1287/1084/851 300 840 840 27.5 45 950 950 6 31/37/42
5.07 (4.75 -5.82) 4360 (4080 - 5000) 4.45 (4.14 - 5.18) 7.24 (6.76 - 8.37) 6230 (5810 - 7200) 42 (32 - 77) 41 (32 - 76) 1525/1212/1088 300 840 840 27.5 45 950 950 6 38/41/46 3/4 1/2 12.6 (10.9 - 16.4) 33.5 (29.3 - 43.8) 0.9 (0.83 - 1.04) 0.67 (0.63 - 0.78) 220-240/1/50
7.29 (6.45 - 8.76) 6270 (5550 - 7530) 6.2 (5.4 - 7.7) 10.53 (9.53 - 12.47) 9050 (8190 - 10720) 58 (38 - 125) 58 (38 - 126) 1857/1410/1191 300 840 840 30 45 950 950 6 38/43/49
11.5 (8.1 - 14.8) 26.1 (19.3 - 37.2) 0.87 (0.72 - 0.99) 0.62 (0.54 - 0.69)
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
324
22.6 (17.7 - 33) 45.7 (38.3 - 62.1) 1.30 (1.15 - 1.58) 0.96 (0.87 - 1.14)
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS The360º panel Art Flux Cassette unit provides an even, fast airconditioning controller that is far-reaching with no dead zones due to its additional motor, which allows the louvres to swing between 37 and 42º. The unit is so compact and light that it can be integrated into any space, including shallow ceilings, without sticking out.
DC INVERTER FAN
• • • • • • •
Condensation pump. Fresh air supply and air blow towards adjacent rooms. Standard extended drainage pan. Optional pipework kit. Optional three-way valve. Optional ON/OFF valve driver. DC Inverter fan motor.
+ +
SAME PANEL AS VRF - ART FLUX 360º UNITS
KID-02 S *Kaysun controller recommended
CASSETTE 2 PIPES
CASSETTE 4 PIPES
COMPATIBLE CONTROLLERS INDIVIDUAL WIRELESS KID-02 S KI-02.3 S
INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR
CENTRALISED KCCT-64 I (B) KCC-64 WEB
MANAGEMENT SYSTEM
BMS INTEGRATION SYSTEMS
KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET
WIFI CONTROL K01-WIFI
For further information, please see our Controllers range.
KIT TUB FC CIS-2T
KV3-FC 3/4
COMPATIBLE ACCESSORIES 4 PIPES
KACT-0
ACCESSORIES FOR 2 PIPES UNITS
KIT TUB FC CIS-4T
KV3-FC 1/2 KV3-FC 3/4
KACT-0
ACCESSORIES FOR 4 PIPES UNITS
MODEL
DESCRIPTION
MODEL
DESCRIPTION
KIT TUB FC CIS-2T
Pipework kit for valve Cassette unit with 2 pipes
KIT TUB FC CIS-4T Pipework kit for 4-pipes Cassette model valves
KV3-FC 3/4
3-way valve 3/4
KACT-O
on/off Actuator
KV3-FC 1/2
3-way valve 1/2 (hot water)
KV3-FC 3/4
3-way valve 3/4 (cool water)
KACT-O*
on/off Actuator
FANCOILS FANCOILS
COMPATIBLE ACCESSORIES 2 PIPES
*You will need 2 actuators for your 4-Ducts Fan Coil.
325
WATER TERMINAL UNITS PRODUCT RANGE DUCTS
Ducts TECHNICAL SPECIFICATIONS 2 PIPES MODEL
DC
DC
DC
DC
KFC-PD-2T-200-1 KFC-PD-2T-300D KFC-PD-2T-400D KFC-PD-2T-600D KFC-PD-2T-800D
kW 1.91 (1.68 - 2.2) 2.72 (2.1 - 3.12) 3.26 (2.5 - 3.99) 4.82 (3.78 - 5.85) 6.36 (5.08 - 8.02) Capacity (min.- max.) Kcal/h 1700 (1450 - 1890) 2340 (1810 - 2680) 2800 (2150 - 3430) 4140 (3250 - 5030) 5470 (4370 - 6900) Rated total Rated sensitive cooling (min.-max.) 1.35 (1.15 - 1.52) 2 (1.49 - 2.53) 2.44 (1.8 - 3.1) 3.58 (2.7 - 4.49) 4.74 (3.64 - 6.19) cooling kW 3.08 (2.59 - 3.5) 3.61 (2.71 - 4.51) 4.55 (3.27 - 5.52) 6.35 (4.81 - 7.84) 8.46 (6.68 - 10.88) Rated heating (min.-max.) Kcal/h 2650 (2230 - 3010) 3100 (2330 - 3880) 3910 (2810 - 4750) 5460 (4140 - 6740) 7270 (5740 - 9360) Rated cooling (min.-max.) W 33 (22 - 49) 12 (7 - 20) 15 (9 - 26) 24 (12 - 49) 28 (16 - 60) Power consumption Rated heating (min.-max.) W 33 (22 - 49) 13 (8 - 23) 16 (9 - 28) 25 (13 - 52) 30 (17 - 65) Static pressure available (high/medium/low) Pa 12/30/50 Air flow (high/medium/low) m3/h 340/255/170 596/442/311 734/564/389 1022/760/544 1452/1038/781 H mm 241 241 241 241 241 Unit Width mm 741 841 941 1161 1461 dimensions Depth mm 222 522 522 522 522 N.W. of the unit Kg 14.6 19 21 23.7 33 Sound pressure (low/medium/high) dB (A) 26/32/35 37/44/50 38/45/52 42/49/57 42/49/58 Hydraulic connections Ø Inches 3/4 Rated cooling (min. - max.) kPa 8.9 (6.7 - 14) 16.4 (11.3 - 23.8) 9.3 (5.8 - 13) 22 (14.2 - 31.4) 20.5 (13.9 - 31.6) Evaporator pressure drop Rated heating (min. - max.) kPa 6.2 (4.4 - 10.5) 12.9 (8.5 - 19.2) 7.7 (4.8 - 10.8) 18.2 (11.4 - 26.4) 16.9 (11.5 - 26.3) Rated eater flow (min. - max.) 0.48 (0.37 - 0.6) 0.57 (0.43 - 0.69) 0.85 (0.65 - 1.05) 1.11 (0.89 - 1.42) m3/h 1.11 (0.89 - 1.42) Power supply V/ph/Hz 220-240/1/50 *Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
4 PIPES MODEL
KFC-PD-4T-200-1 KFC-PD-4T-300-1 KFC-PD-4T-400-1 KFC-PD-4T-600-1 KFC-PD-4T-800-1
kW Capacity (min.- max.) Kcal/h Rated total Rated sensitive cooling (min.-max.) cooling kW Rated heating (min.-max.) Kcal/h Rated cooling (min.-max.) W Power consumption Rated heating (min.-max.) W Static pressure available (high/medium/low) Pa Air flow (high/medium/low) m3/h H mm Unit Width mm dimensions Depth mm N.W. of the unit Kg Sound pressure (low/medium/high) dB (A) Cooling operation Inches Hydraulic connections Ø Heating Inches Rated cooling (min. - max.) kPa Evaporator pressure drop Rated heating (min. - max.) kPa Rated eater Cooling operation m3/h flow (min. Heating m3/h max.) Power supply V/ph/Hz
1.76 (1.52 - 2) 2.35 (2.13 - 2.7) 3.15 (2.76 - 3.6) 1510 (1310 - 1720) 2020 (1830 - 2320) 2710 (2370 - 3100) 1.29 (1.1 - 1.38) 1.43 (1.27 - 1.86) 1.97 (1.57 - 2.48) 2.64 (2.22 - 3) 3.48 (3 - 4) 4.47 (3.9 - 5.2) 2270 (1910 - 2580) 2990 (2580 - 3440) 3840 (3350 - 4470) 33 (22 - 49) 53 (32 - 64) 66 (19 - 75) 33 (22 - 49) 53 (32 - 64) 66 (19 - 75) 12/30/50 340/255/170 510/385/255 680/510/340 241 241 241 741 841 941 522 522 522 15.1 17.5 20.7 26/32/35 27/33/36 28/34/37 3/4 3/4 4.8 (3.5 - 7.6) 9.67 (6.84 - 14.4) 5.85 (3.64 - 8.2) 4 (2.75 - 6.8) 8.39 (5.54 - 12.5) 16.75 (10.44 - 23.5) 0.24 (0.20 - 0.34) 0.46 (0.28 - 0.46) 0.52 (0.39 - 0.62) 0.18 (0.15 0.26)
1020/765/510 241 1161 522 23.5 30/36/40
1360/1020/680 241 1461 550 32.4 33/39/43
12.1 (7.76 - 17.2) 12.19 (8.27 - 18.8) 29 (17.56 - 40.7) 13.29 (9.1 - 20.7) 0.72 (0.54 - 0.86) 0.91 (0.73 - 1.17)
0.28 (0.20 - 0.34) 0.38 (0.29 - 0.45) 0.52 (0.40 - 0.62) 0.64 (0.52 - 0.83) 220-240/1/50
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
326
4.32 (3.84 - 5) 5.78 (5.11 - 6.8) 3710 (3300 - 4300) 4970 (4390 - 5850) 3.29 (2.34 - 3.99) 3.86 (2.73 - 4.68) 6.19 (5.33 - 7.2) 8.45 (7.2 - 9.6) 5320 (4580 - 6190) 7270 (6190 - 8250) 100 (57 - 114) 145 (72.5 - 154) 100 (57 - 114) 145 (72.5 - 154)
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS • • • • • • • •
The duct type units include a tilted evaporator; it provides a wider exchange area and a compact and reduced height, which facilitates the unit installation in rooms where ceilings are just 241 mm high. Similar characteristics to direct expansion ducts, except that it does not have a condensate pump. • • •
Plate to support duct during suction/discharge. 3 pipe rows. DC Inverter Fan (depending to the model).
Removable filter without opening the duct unit case. Replaceable outlet panel (rear/lower). Fresh air supply. Available pressure 12/30/50 Pa Standard extended drainage pan on the left-hand side. Optional left/right pipework kit. Optional three-way valve. Optional on/off valve driver.
COMPATIBLE WITH
Compatible with
Thermostat KC-FC-2T (2 Ducts) KC-FC-4T (4 Ducts)
Compatible with
DUCT 2 PIPES
DUCT 4 PIPES
Interface to control
COMPATIBLE WITH
Thermostat KC-FCD-2T (2 Ducts)
+ CONTROLLER CHOOSE YOUR
CONTROLLERS COMPATIBLE WITH THE INTERFACE TO KAYSUN CONTROLLER INDIVIDUAL WIRELESS KID-02 S KI-02.3 S
INDIVIDUAL WIRED KC-01 S KC-02.1 H KCT-02.1 SR
CENTRALISED KCCT-64 I (B) KCC-64 WEB
MANAGEMENT SYSTEM
BMS INTEGRATION SYSTEMS
KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
WIFI CONTROL
K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET
K01-WIFI
For further information, please see our Controllers range.
COMPATIBLE ACCESSORIES 2 PIPES
COMPATIBLE ACCESSORIES 4 PIPES
IT INCLUDES: • 3 BUTTONS
K01-FC-2T
KIT TUB FC PD-2T-1
KV3-FC 3/4 KACT-0
KC-FC-2T KC-FCD-2T
ON/OFF HOT/COLD 3 SPEEDS
K01-FC-4T
KIT TUB FC PD-4T-1
KV3-FC 3/4 KACT-0 KC-FC-4T
• DIRECTIONAL BUTTONS FOR INCREASING/ REDUCING TEMPERATURE • TIMER
ACCESSORIES FOR 4 PIPES UNITS
MODEL
DESCRIPTION
MODEL
DESCRIPTION
KIT TUB FC PD-2T-1
Plumbing kit for 2-pipes low profile pipes valves
KIT TUB FC PD-4T-1
Plumbing kit for 4-pipes low profile pipes valves
KV3-FC 3/4
3-way valve 3/4
KV3-FC 3/4
3-way valve 3/4
KACT-O
on/off Actuator
KACT-O*
on/off Actuator
K01-FC-2T
Interface to KAYSUN 2T control
K01-FC-4T
KAYSUN 4T control interface
KC-FC-2T
Thermostat 2 pipes
KC-FC-4T
Thermostat 4 pipes
KC-FCD-2T
2 Ducts thermostat with display
FANCOILS FANCOILS
ACCESSORIES FOR 2 PIPES UNITS
*You will need 2 valves and 2 actuators for your 4-Ducts Fan Coil.
327
WATER TERMINAL UNITS PRODUCT RANGE DUCTS
HIGH PRESSURE DUCTS 2 PIPES TECHNICAL SPECIFICATIONS 2 PIPES MODEL kW Capacity (high) Kcal/h Rated total Rated sensitive cooling capacity (high) cooling kW Rated heating capacity (high) Kcal/h Power consumption W Static pressure available (high/medium/low) Pa Air flow (high/medium/low) m³/h H mm Unit Width mm dimensions Depth mm N.W. of the unit Kg Sound pressure (low/medium/high) dB (A) Hydraulic connections Ø Inches Rated cooling (min. - max.) kPa Evaporator pressure drop Rated heating (min. - max.) kPa Rated eater flow (min. - max.) m³/h Power supply V/ph/Hz
KFC-PDH-2T-1000
KFC-PDH-2T-1400
KFC-PDH-2T-1800
KFC-PDH-2T-2200
8.8 7570 6.06 13.2 11350 350 70 1700/1530/1380 400 946 816 52 36/43/50
12 10320 8.26 17.9 15390 350 70 2380/2120/1860 400 946 816 54 38/45/52
15.8 13590 10.88 23.8 20460 800 100 3060/2750/2450 400 1290 809 76 46/53/60
19.9 17110 13.7 30 25800 950 100 3740/3360/2990 400 1290 809 76 47/54/61
24 25 1.51
36 34.2 2.06
90 85 2.72
130 121 3.42
3/4
220-240/1/50
*Calculation conditions: Cooling: Inlet/outlet water temperature 7/12ºC; indoor temperature 27ºC dry bulb, 19ºC wet bulb, fan in high speed. Heating: Water inlet temperature 50ºC, and indoor temperature 20ºC with a dry bulb. Fan in high speed. Same water flow as in Heating mode. Sound pressure is measured in an anechoic chamber at 1 m distance from the unit.
328
Inspiration, Innovation, Evolution
GENERAL CHARACTERISTICS With the help of these ducts, the indoor unit is able to reach up to 100pa (1800 and 2200 models). This results in flexible ducts that make air-conditioning easier, more accurate and adaptable to every space, even in high ceilings rooms.
•
2 Pipes.
•
Flanges in suctions/discharge for duct fitting.
COMPATIBLE WITH
Thermostat KC-FC-2T
Compatible with
Thermostat KC-FCD-2T
+
Compatible with
CHOOSE YOUR
Interface to control
COMPATIBLE WITH
CONTROLLER
1800 - 2200 MODELS
1000 - 1400 MODELS
CONTROLLERS COMPATIBLE WITH THE INTERFACE TO KAYSUN CONTROLLER INDIVIDUAL WIRELESS
INDIVIDUAL WIRED
KID-02 S KI-02.3 S
MANAGEMENT SYSTEM
CENTRALISED
KC-01 S KC-02.1 H KCT-02.1 SR
KCCT-64 I (B) KCC-64 WEB
BMS INTEGRATION SYSTEMS
KAYNET CONTROL K02-MODBUS K01-MODBUS 1 K01-MODBUS 4 K01-MODBUS 8 K01-MODBUS 32
K01-LON K01-KNX 1 K01-KNX 16 K01-KNX 64 K01-BACNET
WIFI CONTROL K01-WIFI
For further information, please see our Controllers range.
COMPATIBLE ACCESSORIES
IT INCLUDES: • 3 BUTTONS
KACT-0
K01-FC-2T
KC-FC-2T
KC-FCD-2T
ACCESSORIES.
• DIRECTIONAL BUTTONS FOR INCREASING/REDUCING TEMPERATURE • TIMER
MODEL
DESCRIPTION
KIT TUB FC PDH-2T
Pipework kit for valve High Static Pressure Ducts
KIT TUB FC PDH-2T-1400
Pipework kit for valve High Static Pressure Ducts (model 1400)
KV3-FC 3/4
3-way valve 3/4
KACT-O
on/off Actuator
K01-FC-2T
Interface to KAYSUN 2T control
KC-FC-2T
Thermostat 2 pipes
KC-FCD-2T
2 Ducts thermostat with display
FANCOILS FANCOILS
KV3-FC 3/4
ON/OFF HOT/COLD 3 SPEEDS
329
WATER TERMINAL UNITS PRODUCT RANGE KEY INSTALLATIONS
REFERENCES KEY INSTALLATIONS
TEA SHOP OFFICES BUSINESS CENTRE Location: Barcelona Initial situation: Renovation Units installed: Cassette 600x600 Capacity: 65 kW
330
FANCOILS FANCOILS
Inspiration, Innovation, Evolution
331
WATER TERMINAL UNITS PRODUCT RANGE KEY INSTALLATIONS
THE INDOOR UNITS OF THE FANCOIL RANGE ARE THE BEST COMPLEMENT FOR THE NEXUS RANGE CHILLERS. THE FANCOILS RANGE INCLUDES A WIDE VARIETY OF MODELS AND CAPACITIES THAT ARE AVAILABLE IN 2 AND 4 PIPES CONFIGURATIONS. THESE HIGHLY VERSATILE UNITS ADAPT TO EVERY TYPE OF INSTALLATION.
SUN BEACH APARTMENTS
Location: Santa Ponça Initial situation: Renovation Units installed: Wall Capacity: 55 kW
OTHER CUSTOMERS THAT HAVE TRUSTED KAYSUN FANCOILS BUSINESS CENTRES AND OFFICES Cardomore Water Plant (Ibiza), CIE Galfor (Orense),
332
PUBLIC BUILDINGS “Miguel Rodríguez” Multipurpose Centre for Elderly People Comprehensive Care (Cadiz), Museo de la Cruz Museum (Córdoba)
HOTELS Andreas Apartments (Majorca)
Inspiration, Innovation, Evolution
TEA SHOP OFFICES
SANTO ANGEL SCHOOL
BUSINESS CENTRE
PUBLIC BUILDING
Location: Barcelona Initial situation: Renovation Units installed: Cassette 600x600 Capacity: 65 kW
Location: Madrid Initial situation: Renovation Units installed: different models Capacity: 95 kW
JUAN MARCH HOSPITAL
REGINA PARK HOTEL
PUBLIC BUILDING
HOTEL
Location: Mallorca Initial situation: Renovation Units installed: Cassette 600x600 Capacity: 330 kW
Location: Ibiza Initial situation: Renovation Units installed: different models Capacity: 195 kW
COEPS FIRE BRIGADE HEADQUARTERS
LLOBREGAT WATER PLANT
PUBLIC BUILDING
BUSINESS CENTRE
Location: Barcelona Initial situation: Renovation Units installed: Cassette 840x840 and 600x600 Capacity: 75 kW
FANCOILS FANCOILS
Location: Seville Initial situation: Renovation Units installed: KEM 30 DHN2KH + 6 KFC PD + RITE 4000.2+ Capacity: 30 kW
333
CONDITIONS OF SALE 1.- ORDERS An order is considered to be the receipt of a written document (via mail, Fax or regular mail which includes the description of the materials requested, order reference, delivery time requested, expected place of delivery and any data that may be required for the successful confirmation in the process of accepting the invoice. For telephone orders, delivery of the materials shall be subject to receipt of the written confirmation of the order with the data described above. For orders of materials or specially manufactured equipment not generally available in stock, a deposit of 30% of the total amount of the final price of the equipment will be required as a prerequisite to its manufacture.
2.- ORDER CANCELLATION Only those cancellations will be accepted that have been notified in writing prior to deliver the goods. Under no circumstances may orders be cancelled for materials or equipment that are specially manufactured and not generally in stock. Additional the buyer waives the right to a refund of the 30% of the total amount of the final price of the equipment invoiced prior to its manufacture.
Deliveries of the goods by ourselves cannot be at a specific time of day, such deliveries being for the account of the buyer by any means he deems appropriate. Complaints about the material or equipment delivered with defects arising from the transport shall be made within 24 Hours of receipt. Claims made after this will be exempt.
6.- Returns The buyer may request return of those materials and equipment for reasons beyond his will provided that the packaging and operation are in a perfect condition for approval by Frigicoll SA and subsequent return of the same after written and signed acceptance and return number provided. A written and numbered authorization from Frigicoll is essential for receipt of the goods in our facilities and the costs of carriage for the aforementioned return will always be for the account of the buyer A demerit of 15% of the value of the sale will be applied. If after inspection of the material does not meet these requirements there will be a devaluation from your payment, which may be up to the total original invoice value of your order.
7.- GUARANTEES 3.- PRICES The prices published in the price list include the carriage of material supplied in our warehouses, the warehouses or premises of the buyer or on site by truck throughout the Peninsula. Outside this area, the cost of transport will be charged based on the place of delivery. All the data quoted in this catalogue are subject to change without prior notice, including the possible typographical errors. Prices do not include value-added taxes (VAT), RAE for machines of less than 12kW or any other tax in force and will always will be for the buyer's account.
4.- DELIVERY TIME The buyer shall indicate the delivery time for the materials that he requests. When any of the materials are not available from stock, a forecast delivery date will be provided for guidance and in no case will a failure to meet this be the cause of a claim on the part of the buyer.
The equipment supplied will have a minimum of 2 years garantee against manufacturing defects provided that its installation and use is appropriate, and in no case can faults be attributable to the guarantee that arise from improper installation, abnormal use, inappropriate electrical voltage, faulty maintenance, use of materials not approved by Frigicoll SA, and manipulation by people not approved for this purpose. The guarantee will cover the replacement of parts and components in poor condition by new parts, but in no case the labour required for that purpose.
8.- JURISDICTION The general conditions of sale shall be construed as being accepted by the buyer at time of ordering. In the case of any disagreement that may arise between the parties, these expressly commit themselves to the courts of Barcelona with express waiver of any other jurisdiction that might apply.
9.- SPECIFICATIONS AND IMAGES 5.- DELIVERY CONDITIONS Standard incoterms would be Ex-Works Vilarodona. Other conditions to be agreed individually.
The manufacturer reserves the right to change the specifications and images of the product without prior notice.
Inspiration, Innovation, Evolution
Main Office Blasco de Garay, 4-6 08960 Sant Just Desvern (Barcelona) Phone: 93 480 33 22
www.frigicoll.es www.kaysun.es
DEPARTMENTS (Fax) HVAC and Energy 93 480 33 23 Catering/Hotel and Cooling 93 371 59 10 Household Appliances 93 371 59 10 Transport Refrigeration 93 473 31 40 Spare Parts 93 473 27 02
MADRID Senda Galiana, 1 PolĂgono Industrial Coslada 28820 Coslada (Madrid) Phone: 91 669 9701 Fax: 91 674 2100 madrid@frigicoll.es
Kaysun participates in the EUROVENT certification program. The products correspond to those listed into the EUROVENT certified products directory.