Andie Skene Presents: 2341 Parker Street

Page 1

Classic Character Home in Grandview 2341 Parker Street • Vancouver, BC

Key Facts & Features

Permits are weeks away from approval by the City of Vancouver for 3 strata homes:

Front Duplex - 1,900 sq. Ft., 5 bedrooms, 3 bathrooms. Post permit plans to add separate entry to nanny / in-law suite w/ private entry and laundry - 2 beds, 1 bath apx. 600 sq. Ft. Private top floor master suite. Private front patio and entry.

Rear Duplex - 1,100 sq. ft. 3 bedrooms, 2.5 baths. Private back patio / garden. 1 outdoor parking.

Coach House - 560 sq. ft. 1 bedroom, 1 bathroom. Private back patio. 1 car garage. Potential to convert the garage into second and or third bedroom or living space post permits apx. 220 sq. Ft. Total of 780 sq. Ft.

Total City Hall “allowable permit” square footage is 3,420 sq ft. The front and rear duplexes and the laneway house are stratifiable units so all 3 can be sold separately.

ALL BUILDING DIMENSIONS, SETBACK AND YARDS ARE TO BE OUTSIDE OF CLADDING

4'-4" 22'-2" CLD-CLD 24'-11" CLD-CLD 9'-81 2 12'-51 2 7'-11" 17'-10" 2'-4" 29'-91 2 FDN-FDN 8'-10" 12'-81 2 8'-6" 14' 3'-10" 2'-4" 9'-101 2 30'-01 2 CLD-CLD 6'-1 1 2 13'-7" 6'-3 1 2 9'-2 1 2 5'-4" 11'-5 1 2 25'-9" FDN-FDN 10'-61 2 10'-01 2 4'-4" 2'-2" 6'-9" 3' 24'-11" CLD-CLD 9'-101 2 24'-8" FDN-FDN 24'-8" FDN-FDN 21'-11" FDN-FDN 29'-91 2 FDN-FDN 26' CLD-CLD 30'-01 2 CLD-CLD 2.5'X4' CLEARANCE UP 2'-10" 3'-9" 3'-9" 4'-4" 3' 2'-10" 21'-11" FDN-FDN 9'-1" 14'-6 2 26'-5" FDN-FDN 11'-2 2 5' 19'-10 2 19'-2 2 13'-4 2 115'-6 2 14'-0 2 129'-9 2 FDN-FDN 7'-1" 4'-7" 5'-10" 3'-10" 14'-4 2 111'-5 2 17'-1 2 110'-4 2 18'-2 2 111'-5 2 14'-0 2 129'-9 2 FDN-FDN 17'-1 2 5'-5 1 3'-7" 6'-5" 9'-0 1 2 9'-9" 25'-9" FDN-FDN 15'-0 2 26'-5" FDN-FDN 15'-0 2 5'-10" 7'-2 3'-4" 7'-1" 13'-0 2 13'-0 2 2'-8" 26'-8" CLD-CLD 26'-8" CLD-CLD 130'-0 2 CLD-CLD 130'-0 2 CLD-CLD 26' CLD-CLD 22'-2" CLD-CLD DN 3'-4" 3' 4' 16'-9 2 2" 4'-5 4'-5 2" 7'-1" 2'-10" 3' 4' 3'-10" 14'-8 2 3' 16'-2" 6' 8'-6" 2'-6" 1'-9" 3'-10" 8'
DRAWING TITLE PROJECT REVISION NO REVISION: DATE NO : N.B ewan DESIGN + CONSTRUCT INC TWO UNIT MULTIPLE CONVERSION DWELLING AND INFILL PROPOSED and EXISTING HOUSE FLOOR PLANS JUNE, 2022 1-4"=1'-0" N.J A3 2341 PARKER STREET VANCOUVER B.C. RETENTION ADDITION / IN-FILL
1'-9" 7'-1" 31'-9" 10'-8 1 2 1'-9" 1'-9" 7'-2 1 2 11'-1" 11'-1" 26'-8" 138'-10 2 138'-11 2 138'-10 2 165'-7 2 17'-1 2 117'-10 2 FDN-FDN 4' 14'-2" 15'-2" CLD-CLD 20'-4" FDN-FDN 5'-8" 17'-8 2 14'-11" 5'-8" 10'-5" 7'-4" 6'-10" 20'-7" CLD-CLD 18'-0 CLD-CLD 20'-7" CLD-CLD 14'-11" FDN-FDN 17'-11" FDN-FDN 18'-0 1 2" CLD-CLD 131'-9 2 26'-8" 1'-9" 7'-3 1 2 8'-11" 5'-11 1 2 DRAWING TITLE PROJECT : REVISION NO REVISION: DATE NO : N.B ewan DESIGN + CONSTRUCT INC TWO UNIT MULTIPLE CONVERSION DWELLING AND INFILL PROPOSED and EXISTING HOUSE FLOOR PLAN+ROOF PLAN JUNE, 2022 1-4"=1'-0" N.J A4 2341 PARKER STREET VANCOUVER B.C. RETENTION / ADDITION / IN-FILL
KEY MATERIALS 1aACRYLIC STUCCO ON EXPANDED METAL LATH 1bEX. STUCCO 02CEDAR SHINGLES 0 32X10 WOOD BARGE BOARD W/ 1X4 0 42X 12 WOOD FASCIA W/ ALUM. GUTTER 0 5VINYL DOUBLEG LAZED WINDOW WIDE PROFILE, BALANCED SASH TRUE DIVIDED GLAZING OR EQUIV. W/ EXT.GRILL & SPACER BARS OF COMPATIBLE COLO U R 0 6WINDOW / DOOR WOOD TRIMS: TOP2X4 SIDE 2X4 SILL2X3 APRON 2X3 0 7SOFFITS AND OVERHAN G 08TIMBER DOORPAINTED 096 X 6 WOOD COLUMN 1 0 -ASPHALT SHINGLESGREY 1 13'-6'' WOOD G UARDRAIL: POSTS 6X6 W/ 8''X8'' CAP TOP2X6 W/ 2X4 BOTTOM2X4 VERTICAL2X3 @ 6'' O.C. 1 2EXPOSED AGGREGATE STAIRS 127'-1 2 8' 15'-8 2 12'-5" 8' 15'-8 2 1' 12'-5" 127'-1 2 9' 1' 8' 17'-7 2 26'-10" 127'-1 2 9' 17'-7 2 15'-8 2 8' 12'-5" 1' 8' 26'-10" 1' 17'-7 2 26'-10" 9' 1' 8' 17'-8 2 DRAWING TITLE PROJECT REVISION NO REVISION: DATE NO : N.B ewan DESIGN + CONSTRUCT INC TWO UNIT MULTIPLE CONVERSION DWELLING AND INFILL PROPOSED and EXISTING HOUSE ELEVATIONS JUNE, 2022 1-4"=1'-0" N.J A7 2341 PARKER STREET VANCOUVER B.C. RETENTION ADDITION / IN-FILL
17'-4" 1'-9" 2'-2" 7'-5" 1' 7' 110'-0 2 19'-2 2 1' 7'-5" 8' 1' 9'-11" 1'-7" 16'-3 2 1' 9'-11" 117'-2 2 18'-11" 5'-1" 10'-0 1 2 5'-0 1 2 10'-5" 9'-9" 19'-11" FDN-FDN 20'-2" CLD-CLD 114'-2 2 7'-4" 121'-3"2 FDN-FDN 121'-6"2 CLD-CLD 2'-5" 15'-7" 2'-2" 10'-5" 9'-9" 19'-11" FDN-FDN 20'-2" CLD-CLD 16'-3" 5'-3" 121'-3"2 FDN-FDN 121'-6"2 CLD-CLD 111'-7 2 20'-2" CLD-CLD 19'-11" FDN-FDN 5'-4" 111'-9 2 116'-10"2 FDN-FDN 117'-1"2 CLD-CLD 7'-5" 9'-7" 19'-11" FDN-FDN 20'-2" CLD-CLD 15'-5 2 116'-10"2 FDN-FDN 117'-1"2 CLD-CLD 3'-2" 3'-4" 110'-5 2 16'-2 2 10'-11" 8070 O/H 3'-4" 5'-3" 9'-8" 5'-3" 1'-9" DRAWING TITLE PROJECT REVISION NO REVISION: DATE NO : N.B ewan DESIGN + CONSTRUCT INC TWO UNIT MULTIPLE CONVERSION DWELLING AND INFILL INFILLMAIN FLOOR PLAN, UPPER FLOOR PLAN, ROOF PLAN AND SECTIONS JUNE, 2022 1-4"=1'-0" N.J A8 2341 PARKER STREET VANCOUVER B.C. RETENTION ADDITION / IN-FILL
18'-4" 7'-5" 1' 9'-11" 18'-4" 119'-2 2 16'-0 2 1' 9'-11" 17' 1' 9'-11" 17'-4" 17' 9'-11" 119'-2 2 17'-4" 8' BG135.96 BG136.7 DRAWING TITLE PROJECT REVISION NO REVISION: DATE NO : N.B ewan DESIGN + CONSTRUCT INC TWO UNIT MULTIPLE CONVERSION DWELLING AND INFILL INFILL ELEVATIONS JUNE, 2022 1-4"=1'-0" N.J A9 2341 PARKER STREET VANCOUVER B.C. RETENTION / ADDITION / IN-FILL

BC

Engel & Völkers Kerrisdale | 2126 W 41st Avenue, Vancouver, BC ©2022 Engel & Völkers. All rights reserved. Each brokerage is independently owned and operated. All information provided is deemed reliable but is not guaranteed and should be independently verified. If your property is currently represented by a real estate broker, this is not an attempt to solicit your listing. Andie Skene Asociate Broker & Real Estate Advisor C: 604.762.2215 E: andie@andieskene.com andieskene.com
Classic Character Home in Grandview 2341 Parker Street • Vancouver,

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.