SIAC – BIM STANDARDS PRACTICAL MANUAL A GUIDE TO ENABLING BIM ON BUILDING PROJECTS Version 0.0 1.0 2.0
Date November 2019 January 2020 March 2020
Description Draft First Release Second Release
SIAC BIM Standards – Practical Manual
3
Naming Convention
3.1 Naming Convention General Rules English is the only language used in all naming Use only letters A-Z, number 0-9 for all fields Use (underscore [ _ ]) between Sectors Use (hyphen [ - ]) for spacing in the same Sector DO NOT use (dots ‘.’), (Space) or special characters < > / \ | etc. The file extension shall not be edited or deleted If a particular type of Revit® content doesn’t have a separate naming scheme yet, general rules shall be applied. This type of content will get an own scheme at a certain point.
3.2 BIM Files Naming Convention Not all information on a project will be originated, exchanged or managed in a BIM format. This information will also need to be managed in a consistent and structured way to enable efficient and accurate information exchange. The file naming fields should be as following: Example: SC0009_FIB_B01_XX_SD_EL_CT_V19.rvt Sr. 1 2 3 4 5 6 7 8
Sector Project ID Project Name Building Name Level Scope Discipline Sub Discipline Version
Code SC0009 FIB B01 XX SD EL CT V19
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Refer to SIAC Project ID Faisal Islamic Bank Type Name Level Name Shop Drawings Electrical Cable Tray 2019 Page 24 of 94
Table 3.22.1 3.22.1 3.22.2 3.22.3 3.22.4 3.22.5 3.22.6
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.3 Loadable Family Naming Convention The loadable family file naming fields should be as following: For example: SC_DOR_SNL_WOD_HRS_VPL_TWR.rfa SC_EFX_ISO-SWT-1PH.rfa SC_SCO_REC_RC-45MPa.rfa SC_MEQ_FCU-SNL-FAN.rfa SC_PFT_BEND_PVC-SCH40_DWV.rfa Sr. Sector Code Refer to Table 1 Company SC SIAC 2 Category DOR Door Category 3.22.7 3 Description (if any) SNL-SWN Single Swing 4 Materials (If any) WOD Wood 5 Insulation / Resistance (If any) HRS Heat Resistance 6 Data (If any) VPL Vision Panel 7 Zone (If any) TWR Tower Note: Any Sector that not included in all elements, will be neglected
3.4 Family Types Naming Convention 3.4.1 Types of System Families The System family Type naming fields should be as following: For example: SC_WAL_CMU_250mm_USOG SC_FLR_RC_150mm SC_DCT_SUPPLY_REC SC_PIP_SOIL-PVC Sr. Sector Code Refer to 1 Company SC SIAC 2 Category WAL Wall Category 3 Material / System CMU Concrete Masonry Units 4 Dimensions / Form (if any) 250mm Thickness 5 Description (if any) USOG Under Slab on Grade SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 25 of 94
Table 3.22.7
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
Note: Any Sector that not included in all elements, will be neglected 3.4.2 Types of Model Loadable Families The Model Loadable Family Type naming fields should be as following: For example: D1_2200X800mm_G01, FCU03_DOUBLE FAN, WATER HEATER Sr. Sector Code Refer to 1 ID (if any) D1 Door Number 2 Name 2200X800mm Dimensions 3 Description (if any) G01 Accessories Group Note: Any Sector that not included in all elements, will be neglected
3.4.3 Types of Annotations Loadable Families The Annotations Loadable Family Type naming fields should be as following: For example: SC_GHD_CIRCLE, SC_ROM-TAG_NUMBER Sr. Sector Code Refer to Table 1 Company SC SIAC 2 Category GHD Grid Head 3.22.7 3 Description (if any) CIRCLE Circle Shape 4 Scale (if any) 1-50 1:50 Note: Any Sector that not included in all elements, will be neglected
3.5 MEP Systems Naming Convention The MEP System naming fields should be as following: For example: WS_WASTE, DT_EXHAUST-AIR Sr. 1 2
Sector Sub Discipline MEP System Name
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Code WS WASTE
Refer to Water Supply Waste
Page 26 of 94
Table 3.22.6 3.22.8
SIAC BIM Standards – Practical Manual
3.6 Worksets Naming Convention A workset is a set of elements modeled by users. Only one user can own each workset at a given time. However, all worksets are visible to all team members as ‘read only’ Creating worksets will form a central file that helps users visualize and coordinate their systems easily in a collaboration work-sharing. Note: The Name of Workset is CAPITAL CASE separated with underscore.
The Workset naming fields should be as following: For example: 01_LEVELS_GRIDS, 03_AR_WALLS, 03_HVAC_DUCTS Sr. 1 2
Sector Workset ID Workset Name
Code 02 WASTE-AIR
And the ID is referring to Workset Type as the examples below: ID 01 02 03
Workset Type Levels and Grids Linked CAD Files Linked Revit Files
04
Model Elements
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Workset Name Example 01_LEVELS_GRIDS 02_LINK_CAD 03_LINK_RVT 04_MODEL or 04_AR_WALLS 04_ST_COLUMNS 04_FF_PIPES 04_EL_CABLE_TRAYS
Page 27 of 94
SIAC BIM Standards – Practical Manual
3.7 Revit Views Naming Convention This section shall be managed carefully; otherwise, it will have a great impact across all documentation. Notes: Views Names to be written by (CAPITAL CASE). Level names are spelled out as they need to appear in schedules and Views (as well as how they will appear in sections and elevations). Views can be having Title on Sheet
The Revit View Naming Convention should be as following: For example: SD_BW_GF_SEC_01 SD_SP_L5_PLN_OVERALL_@+330.25 WIP_WS_L4_PLN_PART-01 Sr. 1 2 3 4 5 6
Sector View Category View Package Level Code View Type Description (if any) Elevation (if any)
Code WIP BW GF SEC 01 @+330.25
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Refer to Work in Progress Block Work Level No. 5th Section No. / Overall / Part No. Global Level Elevation
Page 28 of 94
Table 3.22.9 3.22.10 3.22.3 3.22.11
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.8 View Filters Naming Convention The View Filter Naming Convention should be as following: For example: AR_WAL_CMU, ME_DCT_SUPPLY EL_CTR_TELE-CABLE-TRUCK Sr. Sector Code 1 Discipline AR 2 Category WAL 3 Description CMU
Refer to Architectural Walls Any Description
Table 3.22.5 3.22.7
3.9 View Templates Naming Convention The View Templates Naming Convention should be as following: For example: COR_GN_3D_NTS SD_SB_PLN_1-50 SD_FN_PLN_SOG_1-50 SD_SP_PLN_1-100 SD_BW_PLN_KEY-PLAN_1-100 SD_BW_SEC_1-25 WIP_PLN_1-100 Sr. 1 2 3 4 5
Sector View Category View Package View Type Description (if any) Scale
Code WIP BW PLN KEY-PLAN 1-100
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Refer to Work in Progress Structural Structural Plans Any Description 1:100
Page 29 of 94
Table 3.22.9 3.22.10 3.22.11
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.10
Arrowhead Type Naming Convention
The Arrowhead Naming Convention should be as following: For example: SC_DIA_2.0, SC_DOT-OPN_2.5, SC_ARR-FLD_3.5 Sr. 1 2 3
3.11
Sector Company Arrow Style Arrow Size
Code SC DIA 2.0
Refer to SIAC Diagonal 2.0 mm
Table 3.22.14
Text Note Naming Convention
The Text Note Naming Convention should be as following: For example: SC_DIA_2.0, SC_ARR-OPN_3.5_STAIRS Sr. 1 2 3 4
Sector Company Arrow Style Text Size Description (if any)
Code SC DIA 2.0 STAIRS
Refer to SIAC Diagonal 2.0 mm Any Description
Table 3.22.14
Notes: Text Styles may be added by Project Manager as per project needs Text Font is ARIAL
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 30 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.12
Dimensions Naming Convention
The Dimensions Naming Convention should be as following: For example: SC_DIA_2.0_STAIRS Sr. 1 2 3 4
Sector Company Arrow Style Text Size Description (if any)
Code SC DIA 2.0 STAIRS
Refer to SIAC Diagonal 2.0 mm Any Description
Table 3.22.14
Notes: Text Styles may be added by Project Manager as per project needs Tick Mark is DIAGONAL Text Font is ARIAL
3.13
Linked CAD Files Naming Convention
The Linked CAD Naming Convention should be as following For example: ME_DR_L08_IR_DR108P1_REV-2 AR_BW_GR_BW_SF101P1_REV-3 Sr. 1 2 3 4 5 6
Sector Discipline Sub Discipline Level View Package Design DWG. No. DWG Revision No.
Code ME DR L08 IR SF101P1 REV-2
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Refer to Mechanical Drainage Level 8th Irrigation Design DWG. No. Revision 2
Page 31 of 94
Table 3.22.5 3.22.6 3.22.3 3.22.10
SIAC BIM Standards – Practical Manual
3.14
Material Naming Convention
The Material Naming Convention should be as following For example: SC_04_Masonry_CMU_Smooth Faced_200x400mm
Sr. 1 2 3 4 5 6
3.15
Sector Company Division ID Division Name Material Name Description Size (if any)
Code SC 04 Masonry CMU Smooth Faced 200x400mm
Refer to SIAC MasterFormat™ Div. ID MasterFormat™ Div. Name Concrete Masonry Units Any Description Dimensions
Table 3.22.13 3.22.13 3.22.12
Schedules Naming Convention
The Schedules Naming Convention should be as following For example: SC_04_Masonry_CMU Sr. 1 2 3 4
Sector Company Division ID Division Name Description
Code SC 04 Masonry CMU
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Refer to Table SIAC CSI MasterFormat™ Div. ID 3.22.13 CSI MasterFormat™ Div. Name 3.22.13 Concrete Masonry Units
Page 32 of 94
SIAC BIM Standards – Practical Manual
3.16
Parameters Naming Convention
The Parameters Naming Convention should be as following: For example: SC_AIR_FLOW_RATE (Shared Parameter) SC_VIEW_PACKAGE (Project Parameter) Window_Width (Family Parameter) Sr. Sector 1 Company 2 Description
Code SC AIR_FLOW_RATE
Refer to SIAC AIR FLOW RATE
Notes: - In Project / Shared / Global Parameters: Company Name should be written in the start of the Name The Letters should be in CAPITAL CASE The Spacing should be ‘_’ (Underscore) Not (Spaces) - In Family Parameters: Company Name should NOT be written in the start of the Name The Letters should be in Camel Case The Spacing should be ‘_’ (Underscore) Not (Spaces)
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 33 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.17 Level Naming Convention The Level Naming Convention should be as following For example: 03_ST_GF@+330.25 Sr. Sector Code Refer to Table 1 Numbering 03 Numbering 2 Discipline ST Structural 3.22.5 3 Level Code GF Ground Floor 3.22.3 4 Elevation (if any) @+330.25 Global Level Elevation Note: Numbering is referring to sorting from the minimum Level
3.18 Line Pattern Naming Convention The Line Pattern Naming Convention should be as following For example: RC_INSULATION, EL_EARTHING-300, Sr. Sector 1 View Package (If any) 2 Description
Code Refer to EL Electrical EARTHING-300 Any Description
Table 3.22.10
Note: The Line Pattern should be created to be in Line Style with the same name.
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 34 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.19 Line Style Naming Convention The Line Style Naming Convention should be as following For example: RC_INSULATION, EL_EARTHING-300, Sr. 1 2
Sector View Package (If any) Description
Code EL EARTHING-300
Refer to Table Electrical 3.22.10 Any Description
3.20 Fill Pattern Naming Convention The Fill Pattern Naming Convention should be as following For example: DRF_PC, MDL_BRICK Sr. Sector Code Refer to 1 Fill Pattern Type DRF Drafting 2 Description BRICK Any Description Note: Fill Pattern Types are (DRF = Drafting, MDL = Model)
3.21 Filled Region Naming Convention The Filled Region Naming Convention should be as following For example: DRF_PC, MDL_BRICK Sr. Sector Code Refer to 1 Fill Pattern Type MDL Model 2 Description BRICK Any Description Note: Fill Pattern Types are (DRF = Drafting, MDL = Model)
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 35 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.22
Naming Convention Abbreviations
3.22.1 Project ID / Name The (project) is an alphanumeric code that is used by the project team to identify the project, for example: Project ID Project Code Name SC0009 FIB FAISAL ISLAMIC BANK Note: The Project ID/Name should be Named by BIM/Project Manager
3.22.2 Building Name Current building codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name Building 01 Building 02 Building 16
Code B01 B02 B16
3.22.3 Level Current building codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name General Foundations Basement Basement(i) Ground Floor Mezzanine Mezzanine(i) First Floor Second Floor Level (i) Floor Roof Floor Upper Roof Floor
Code XX FN BS B(i) GR MZ M(i) L1 L2 L(i) RF UR
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 36 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.22.4 Scope Current document type codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name As Built Clash Report Cost Analysis Navisworks File Shop Drawings Tender Drawings Time Simulation
Code AB CR 5D NW SD TD 4D
3.22.5 Discipline Current role/discipline codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name General Architectural Structural Mechanical Electrical Infrastructural
Code GN AR ST ME EL IN
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 37 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.22.6 Sub Discipline Current sub-discipline codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Dis. GN GN AR AR AR AR ST ST ME ME ME ME ME-IN ME-IN ME-IN EL EL IN IN IN IN
Name General Composite Block Work Model Finishes Furniture Interior Design Steel Structural Formwork Model Chilled Water Drainage Duct Work Water Supply Fire Fighting Force Main Irrigation Low Voltage Light Current Hydrogen Medium Voltage Potable Water Sewage
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Code XX CO BW FN FR ID SS FW CW DR DT WS FF FM IR LV LC HY MV WT SW
Page 38 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.22.7 Category
Category Name
Code
Category Name
Code
Air Terminal Area Balusters Cable Tray Fittings Cable Trays Callout Casework Ceiling Column Communication Devices Conduit Fittings Conduits Curtain Panel Curtain Systems Curtain Wall Curtain Wall Mullions Data Devices Detail Item Doors Duct Duct Accessories Duct Fitting Electrical Equipment Electrical Fixtures Elevation Fill Pattern Fire Alarm Devices Flex Ducts Flex Pipes Floors Furniture Generic Model Grid Head Grids Level Level Head Lighting Devices Lighting Fixtures Mass Mechanical Equipment Multi Categories
AIT ARE BLT CTF CTR CLT CSW CLG COL COM CNF CND CWP CWS CWA CWM DAT DTL DOR DCT DAC DFT EEQ EFX ELV PAT FAD FLD FLP FLR FUR GEN GHD GRD LVL LHD LDV LFX MAS MEQ MCT
Nurse Call Devices Parking Pipe Fitting Pipes Pipes Accessories Planting Plumbing Fixtures Profile Railing Ramp Revision Cloud Roof Room Section Head Section Tail Sections Security Devices Sheet Site Specialty Equipment Spot Elevation Sprinkler Stair Path Stairs Structural Columns Structural Floor Structural Foundations Structural Framing Structural Rebar Structural Stiffeners Structural Trusses Telephone Devices Text Title Block View Reference Views Wall Sweep Walls Walls Finish Windows Wires
NCD PRK PFT PIP PAC PLT PFX PRO RAL RMP REV ROF ROM SHD STL SEC SDV SHT SIT SEQ SPT SPK STP STA SCO SLB SFO SFR SRB STF STR TPD TXT TBK VRE VIW WSW WAL WFI WIN WIR
Note: Any Tag will be added as (-TAG) to its above category abbreviations
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 39 of 94
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.22.8 MEP Systems Current MEP System codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Dis. ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME
Name CAR PARK Chilled Water Return Chilled Water Supply CO2 Condensate Drain Domestic Cold Water Domestic Hot Water Domestic Hot Water Return Drain Dry Exhaust Air Fire Protection Water FM200 FORCED MAIN Fresh Air Hot Water Return Hot Water Supply Inergen IRRIGATION WATER Kitchen Exhaust Air Pre-Action Storm Drain Pressurization Air Smoke Air Stand Pipe Supply Air Vent Waste RAIN WATER Return Air Soil Soil & Waste
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Code CPD CWR CWS CO2 CDP DCW DHW DHWR FD DRY EAD WET FM200 FM FAD HWR HWS ING IRP KAD PA SD PRD SMD SP SAD VP WP RW RAD SP S&W
Page 40 of 94
Dis. EL EL EL EL EL EL EL EL EL
Name Lighting Telecommunication Public Address Security System Small Power Access Control System Cable Containment Earthing & Lightning Fire Alarm
Code LT TEL PA SEC SP ACS CT ER FA
SIAC BIM Standards â&#x20AC;&#x201C; Practical Manual
3.22.9 View Category Current View Category codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name Work in Progress Coordination Shop Drawings As-Built Drawing
Code WIP COR SD AB
3.22.10 View Package Current Package codes for use on the projects, any new codes to be agreed with the client through the BIM Manager and Project Manager. Dis GN GN AR AR AR AR AR AR AR AR AR AR ST ST ST ST ST ST
Name General General Details Block Work Ceiling Doors and Windows Elevations Wet Areas Toilet Details Flooring Interior Design Landscape Life Safety Columns & Axes Piles Plain Concrete Reinforced Concrete Structural Walls Ramps
Code XX GD BW CL DW EV WA TD FL ID LS LF CA PI PC RC RW RM
Dis ME ME ME ME ME ME ME ME ME EL EL EL EL EL EL EL EL EL
ST ST
Stairs Slabs
ST SB
EL EL EL
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Name Sprinklers Layout Chilled Water Machine Rooms Irrigation Fire Cabinet Fire Suppression Water Supply Drainage Ductwork LIGHTING SMALL POWER POWER HVAC FEEDER ROUTING EARTHING & LIGHTNING FIRE ALARM INTEGRATED SYSTEM STRCUTURE CABLING BUILDING MANGEMENT SYSTEM SOUND SYSTEM AUDIO VISUAL QUEUEING SYSTEM
Page 41 of 94
Code SK CW MR IR FC FS WS DR DT LT SP HP FR ER FA IS SC BMS PA AV QS
SIAC BIM Standards – Practical Manual
3.22.11 View Type Current View Type codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name 3D View Area Plan View Callout Detail View Drafting View Elevation View Plan (Floor Plan – Structural Plan) View Reflected Ceiling Plan Section View
Code 3D APL CLT DTL DRF ELV PLN RCP SEC
3.22.12 Material Current Materials codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Dis. AR AR AR AR AR AR AR AR AR AR AR AR AR AR ST ST
Name GLASS GYP-BOARD MASONRY_CMU MASONRY_HOLLOW-BLOCK MASONRY_SOLID-BLOCK MASONRY_STONE METAL_COPPER METAL_STAINLESS-STEEL METAL_STEEL-CARBON METAL-ALUM PAINT PLASTICS THERMAL-MEMBRANE WOOD CONCRETE_PC CONCRETE_RC
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Code GLS GYP CMU HLW SLD STN CPR STL CRB ALUM PNT PLS MBN WOD PC RC
Page 42 of 94
SIAC BIM Standards – Practical Manual
3.22.13 MasterFormat™ ID / Name ID
Name
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 20 21 22 23 25 26 27 28 31 32 33 34 35 40 41 42 43 44 45 46 47 48
Procurement and Contracting Requirements General Requirements Existing Conditions Concrete Masonry Metals Wood, Plastics, and Composites Thermal and Moisture Protection Openings Finishes Specialties Equipment Furnishings Special Construction Conveying Equipment Mechanical Support Fire Suppression Plumbing Heating Ventilating and Air Conditioning Integrated Automation Electrical Communications Electronic Safety and Security Earthwork Exterior Improvements Utilities Transportation Waterways and Marine Construction Process Interconnections Material Processing and Handling Equipment Process Heating, Cooling, and Drying Equipment Process Gas and Liquid Handling, Purification and Storage Equipment Pollution Control Equipment Industry-Specific Manufacturing Equipment Water and Wastewater Equipment RESERVED FOR FUTURE EXPANSION Electrical Power Generation
Note: All these IDs (15,16,17,18,19,24,29,30,36,37,38,39 and 48) = RESERVED FOR FUTURE EXPANSION, as per Latest MasterFormat™
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Page 43 of 94
SIAC BIM Standards – Practical Manual
3.22.14 Arrow Style Current Arrow Styles codes for use on the project, any new codes to be agreed with the client through the BIM Manager and Project Manager. Name Arrow - Filled Arrow - Not Filled - Closed Arrow - Not Filled - Open Dot – Filled Dot – Not Filled Elevation Target – Filled Elevation Target – Not Filled Datum triangle – Filled Datum triangle – Not Filled Box - Filled Box – Not Filled Loop Diagonal Heavy end tick mark
SIAC_BIM_Standards-Practical_Manual-V2.0.docx
Code ARR-FLD ARR-CLS ARR-OPN DOT-FLD DOT-OPN ELV-FLD ELV-OPN TRI-FLD TRI-OPN BOX-FLD BOX-OPN LOP DIA HVY
Page 44 of 94