GRAFIK Systems Sivoia QED Controller

Page 1

TM

GRAFIK Systems Sivoia QED® Controller for use with GRAFIK Eye® 3000/4000 Series Systems ✓ SG-SVC ❑ Internet: www.lutron.com E-mail: product@lutron.com WORLD HEADQUARTERS Lutron Electronics Co. Inc., 7200 Suter Road Coopersburg, PA 18036 TEL +1.610.282.3800 FAX +1.610.282.1243 Toll Free 1.888.LUTRON1 Technical Support 1.800.523.9466 EUROPEAN HEADQUARTERS Lutron EA Ltd., 6 Sovereign Close, Wapping, London E1W 3JF United Kingdom TEL +44.207.702.0657 FAX +44.207.480.6899 FREEPHONE (UK) 0800.282.107 Technical Support +44.(0)20.7680.4481

ASIAN HEADQUARTERS Lutron GL Ltd., 15 Hoe Chiang Road #07-03 Euro Asia Centre Singapore 089316 TEL +65.6220.4666 FAX +65.6220.4333 Hong Kong TEL +852.2104.7733 FAX +852.2104.7633 Japan TEL +81.3.5575.8411 FAX +81.3.5575.8420 Asia Technical Hotlines Northern China: 10.800.712.1536 Southern China: 10.800.120.1536 Hong Kong: 800.901.849 Indonesia: 001.803.011.3994 Japan: +81.3.5575.8411 Macau: 0800.401 Singapore: 800.120.4491 Taiwan: 00.801.137.737 Thailand: 001.800.120.665853 Other Areas: +65.6220.4666 Lutron Electronics Co., Inc. Made and printed in U.S.A. P/N 030-966 Rev.A 10/07

LIMITED WARRANTY Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 180361299, postage pre-paid. This warranty is in lieu of all other express warranties, and the implied warranty of merchantability is limited to one year from purchase. This warranty does not cover the cost of installation, removal, or reinstallation, or damage resulting from misuse, abuse, or improper or incorrect repair, or damage from improper wiring or installation. This warranty does not cover incidental or consequential damages. Lutron’s liability on any claim for damages arising out of or in connection with the manufacture, sale, installation, delivery, or use of the unit shall never exceed the purchase price of the unit. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This products may be covered under one or more of the following U.S. patents: 4,835,343; 4,924,349; DES 422,567; DES 436,930; D453,742; D456,783 and corresponding foreign patents, other patents pending. Lutron, GRAFIK Eye, GRAFIK6000, and Sivoia QED are registered trademarks, and seeTouch GRAFIK5000 and GRAFIK7000 are trademarks of Lutron Electronics Co., Inc. NFPA, National Electric Code, and NEC are registered trademarks of the National Fire Protection Association, Inc., Quincy, Massachusetts. © 2007 Lutron Electronics Co., Inc.

for use with GRAFIK 5000TM GRAFIK 6000® and GRAFIK 7000TM Series Systems ✓ SO-SVC ❑

Software Note: For GRAFIK Eye 3000/4000 Series Systems: GRAFIK Eye Control Unit Software revision 7-1 or greater. For GRAFIK5000/GRAFIK6000/GRAFIK7000 Series Systems: The operating code of the Central Processor must be o300 or later revision. The database must be created using Setup software version 3.xx or later and Operate software version 3.xx or later.


SG/SO-SVCI (insert version)

SG/SO-SVCN (non-insert version)

Indicator LEDs

Indicator LEDs Open Preset 1 Preset 2 Preset 3 Close

OPEN PRESET 1 PRESET 2 PRESET 3 CLOSE

LUTRON

NOTES

OPEN PRESET 1 PRESET 2 PRESET 3 CLOSE

LUTRON

Raise Lower

Open Preset 1 Preset 2 Preset 3 Close

Raise Lower

Button Functionality Pressing the Open, Close, or Preset button will cause the window treatment to move to the selected position. Pressing the same Open, Close, or Preset button a second time while the window treatments are moving will stop the window treatments. Pressing the Raise/Lower buttons will open or close the window treatments while the Raise/Lower button is pressed. Open - Pressing the Open button once will cause the window treatments to move to the open position. Presets - Pressing one of the preset buttons (Preset 1, Preset 2, or Preset 3) will cause the window treatments to move to their programmed preset level. Close - Pressing the Close button once will cause the window treatments to move to the closed position. Raise - Holding the Raise button will cause the window treatments to move towards the open position. Releasing the Raise button will cause the window treatments to stop. Lower - Holding the Lower button will cause the window treatments to move towards the closed position. Releasing the Lower button will cause the window treatments to stop. Note: Open, Preset, Close, Raise, and Lower buttons affect all Sivoia QED Motorized Window Treatments that are connected to the Sivoia QED Controller.

LED Functionality An indicator LED is ON when all of the Sivoia QED Motorized Window Treatments are at the corresponding Open, Close, or Preset position. Otherwise, the indicator LED is OFF.

Installation Instructions

2

Occupant Copy


NOTES

Wallstation and Sivoia QED Controller circuits are classified as Class 2 circuits (U.S.A.) and PELV circuits (IEC). Unless otherwise specified, the voltages do not exceed 12-35 V or 24 V . As Class 2 circuits, they comply with the requirements of NFPA® 70 National Electrical Code® (NEC®). As PELV circuits, they comply with the requirements of IEC 60364-4-41, VDE 0100 Part 410, BS7671:1992 and other equivalent standards. When installing and wiring to these Sivoia QED Controllers, follow all applicable national and/or local wiring regulations. External circuits connected to input, output, RS232, DMX512, and other communication terminals of Wallstations and Sivoia QED Controllers, must be supplied from a Listed Class 2 source or comply with the requirements for PELV circuits, as applicable in your country.

Wiring Notes

GRAFIK Eye 3000/4000 Series Wiring ■ System Maximums: — 8 Unique GRAFIK Eye addresses per system. — 16 Accessory Controls per system. — 8 GRAFIK Eye Motorized Window Treatment controllers per system. — GRAFIK Eye 3000 Series Control Units can power a maximum of 3 Wallstations. — 0 °C - 40 °C operating temperature. ■ Control Link Wiring GRAFIK Eye Link — 3000 Series: Four #18 AWG (1.0 mm2) PELV (Class 2: USA) wires (2 twisted, pair). Lutron offers a one-cable, non-plenum, low-voltage solution (P/N GRX-CBL-346S500), and a one-cable, plenum, low-voltage solution (P/N CAUTION GRX-PCBL346S-500). Other suggested cables are Belden No. 9156, Alpha No. 1132, or equivalent, for GRAFIK Eye ■ Read all instructions before starting installation. 3000 Series Control Units. ■ Lutron recommends that Sivoia QED Controllers be — 4000 Series: Two #12 AWG (2.5 mm2) PELV (Class 2: USA) installed by a qualified electrician. wires and two shielded #18 AWG (1.0 mm2) PELV (Class 2: USA) wires (twisted, shielded pair). Lutron offers a one■ Do not connect line voltage power to PELV (Class 2: cable (non-plenum), low-voltage solution (P/N GRX-CBLUSA) terminals. Improper wiring can result in personal 46L). injury or damage to the control or to other equipment. — Maximum wiring length: 2000 ft. (600 m). ■ Controllers must be connected to the GRAFIK Eye — Power: wires 1 & 2; 12 VDC-24 VFW. Control Unit or Central Processors by using PELV (Class — Data: wires 3 & 4; twisted, shielded pair. 2: USA) wiring methods per the National Electrical Sivoia QED Electronic Drive Unit Link Code. Check with your local electrical inspector for the — Seven conductors (four shielded #18 AWG, two #16 AWG local code requirements and wiring practices allowed in and one #18 AWG) PELV (Class 2: USA). Lutron offers a your area. one-cable, low voltage solution (P/N SVQ-CBL-250). Note: ■ Use only a cloth with warm water and mild soap to Drain is not connected at the GRAFIK Eye Sivoia QED clean faceplates (do not use chemical cleaners). Controller. — Power: wires 5 & 6; 24 V . — Data: wires 1, 3, & 4; twisted, shielded cable. ■ Power to the Sivoia QED Controller is supplied by the Sivoia ). QED Electronic Drive Unit link (24 V ■ Terminal 2 (power) must not be connected between GRAFIK Eye 3000 Series Control Units.

!

Occupant Copy

3

Installation Instructions


■ ■

■ ■

■ ■

Warning: Always turn Off the circuit breaker or remove the main fuse from the power line before doing any work. Failure to do so can result in serious personal injury.

Installation Instructions

Communication between Sivoia QED Controller and G5000/G6000/G7000 Central Processor must be established prior to normal operation. Please refer to the Operate and Maintenance Manual for more information.

Sivoia QED Preset Programming

OFF OFF OFF

ON

ON

Control Link Wiring GRAFIK 5000/6000/7000 Wallstation Link — Two #12 AWG (2.5 mm2) PELV (Class 2: USA) wires and two shielded #18 AWG (1.0 mm2) PELV (Class 2: USA) wires (twisted, shielded pair). Lutron offers a one-cable, non-plenum, low-voltage solution (P/N GRX-CBL-46L), and a one-cable, plenum, low-voltage solution (P/N GRX-PCBL-46L). — Power: wires 1 & 2, 12-35 V . — Data: wires 3 & 4, twisted, shielded pair. Sivoia QED Electronic Drive Unit Link — Seven conductors (four shielded #18 AWG, two #16 AWG and one #18 AWG) PELV (Class 2: USA). Lutron offers a one-cable, low voltage solution (P/N SVQCBL-250). Note: Drain is not connected at the GRAFIK Eye Sivoia QED Controller. — Power: wires 5 & 6; 24 V . — Data: wires 1, 3, & 4; twisted, shielded cable. Power to the Sivoia QED Controller is supplied by the Sivoia QED Electronic Drive Unit link (24 V ). Connection of the Wallstation to the Control Link should be made inside the Wallstation’s wallbox or in a junction box (provided by others) located no more than 8 ft. from control. Control Link wiring must not be run in the same raceway as line voltage wiring. Total Control Link length is not to exceed 2000 ft. (610 m) unless the signal is boosted using a link booster (P/N MX-RPTR). The shield/drain wire must be maintained throughout the Control Link. Do not connect the shield to earth ground. Refer to the Installation Guide and Lutron job drawings for power cable and data cable (Control Link) wiring specifications. Control Link requires a link terminator (LT-1) at each end of the Control Link. Refer to the LT-1 instruction sheet for location and installation information.

ON

GRAFIK 5000/GRAFIK 6000/GRAFIK 7000 System Communications

Installation

GRAFIK 5000/GRAFIK 6000/GRAFIK 7000 Series Wiring

1. Turn power Off to both the GRAFIK Eye 3000/4000 or GRAFIK 5000/GRAFIK 6000/GRAFIK 7000 system and the Sivoia QED system. 2. Mount standard U.S. 1-gang wallbox, 2.75 in. (70 mm) deep (available from Lutron P/N 241-519). 3. Strip insulation from wires so that 3/8 in. (10 mm) of bare wire is exposed for #18 AWG (1.0 mm2) wire.

4. Remove the faceplate, adapter (if applicable), and button assembly from the Sivoia QED Controller to access Address switches.

Preset 1, 2, and 3 are programmable Sivoia QED presets. Preset positions are stored in the Sivoia QED Motorized Window Treatments. All GRAFIK Eye Control Units, G5000/G6000/G7000 Central Processors, and Sivoia QED keypads/IR transmitters command the Sivoia QED Motorized Window Treatments to travel to the same set of presets. Communication between Sivoia QED Controller and Control Unit or Central Processor must be established prior to programming the presets. Set each preset as follows: 1. Adjust the window treatments to the desired position. To adjust window treatments individually, use the Open/Close buttons on the Sivoia QED Electronic Drive Unit. To adjust all window treatments simultaneously, use the Raise/Lower buttons on the Sivoia QED Controller. 2. Press and hold the desired preset button for a minimum of 4 seconds. ‘PR’ will flash on EDU-20 Electronic Drive Unit display or green LED on EDU will flash for 5 seconds and the button LED will flash on the Sivoia QED Controller indicating that the preset has been saved. Note: This preset change will only affect Electronic Drive Units that are connected to the Sivoia QED Controller.

Button Backlight Intensity To change the intensity of the button backlights, follow these steps: 1. Put the Sivoia QED Controller in setup mode (only one Sivoia QED Controller or Wallstation may be in setup mode at a time). Press and hold the Open and Close buttons for about 3 seconds, until the indicator LED(s) start to cycle. Indicator LEDs cycle

Faceplate

Press and hold here for setup mode

Faceplate Adapter Button Assembly

4

Occupant Copy

2. Adjust the button backlight intensity to the desired level using the Raise/Lower buttons on the Sivoia QED Controller. To turn the backlight on, press and hold the Raise button. To turn the backlight off, press and hold the Lower button. 3. Exit setup mode. Press and hold the Open and Close buttons for about 3 seconds until the indicator LEDs stop cycling. Occupant Copy

9

Installation Instructions


9. Mount Sivoia QED Controllers as shown below. Attach faceplate by pressing in at each corner, one corner at a time. Restore power.

5. Address Sivoia QED Controllers. Note that the Address switch addressing is different for 3000/4000 Series and 5000/6000/7000 Series. GRAFIK Eye 3000/4000 Series Addressing. Each Sivoia QED Controller in a Set GRAFIK Eye 3000/4000 system Address must be assigned a unique 1 2 3 4 5 6 window treatment controller address. Set Address Switches 1-3 1 2 3 4 5 6 of each Sivoia QED Controller to one of the positions illustrated below and record its location. Note: For 3000/4000 Series, the Sivoia QED Controller does not occupy one of the 16 standard accessory control addresses. There is a maximum of 8 Window Treatment Controllers per GRAFIK Eye 3000/4000 system.

Wallbox

Wallbox

GRAFIK 5000/6000/7000 Series Addressing. Each Sivoia QED Controller in a Set Address 5000/6000/7000 Series system occupies one of 32 addresses on the 1 2 3 4 5 6 Wallstation link. Refer to Lutron job drawings for any preassigned job 1 2 3 4 5 6 specific address for each control. For proper system operation, each Wallstation or Sivoia QED Controller on a link must have a unique address. Set Address Switches 1-5 on each control to one of the positions illustrated below. ON

ON

Sivoia QED Button Controller Assembly

Sivoia QED Button Controller Assembly Faceplate Adapter

Faceplate Adapter

Faceplate

Faceplate

Mounting Diagram (insert version)

Mounting Diagram (non-insert version)

GRAFIK Eye 3000/4000 System Communications

For this window treatment controller address Set switches Set switches Location: like this: like this: Location: ON

1

Indicator LEDs cycle

ON

2

3

4

5

6

17

ON

2 3

1

1

2

3

4

5

6

18

2

3

4

5

6

19

4

1

1

2

3

4

5

6

20

2

3

4

5

6

21

6

ON

1

2

3

4

5

6

1

2

3

4

5

6

7

2

3

4

5

6

8

ON

22

2

ON

1

2

3

4

5

9

6

ON

1

2

3

4

5

6

23

2

3

4

5

6

24

1

Occupant Copy

1

2

3

4

5

6

10

2

3

4

5

6

11

ON

2

3

4

5

6

1

1

ON

1

25

1

2

3

4

5

6

12

2

3

4

5

6

13

ON

2

3

4

5

6

26

2

3

4

5

6

27

1

1

ON

1

1

2

3

4

5

14

6

1

2

3

4

5

6

28

2

3

4

5

6

29

2

3

4

5

6

1

Occupant Copy

5

1

6

5

6

1

1

2

3

4

5

6

2

3

4

5

1

6

2

3

4

5

6

1

1

2

3

4

5

6

2

3

4

5

1

6

2

3

4

5

6

1

1

2

3

4

5

6

2

3

4

5

6

1

1

2

3

4

5

6

2

3

4

5

6

2

3

4

5

6

2

3

4

5

6

2

3

4

5

6

ON

30

1 ON

2

3

4

5

6

31

2

3

4

5

6

32

ON

16

5

4

ON

ON

15

4

3

ON

ON

8

3

2

ON

ON

7

2

ON

ON

6

1

ON

ON

5

1

ON

ON

2. Identify the individual zone on a GRAFIK Eye Control Unit to be associated with the Sivoia QED Controller (All Units must be addressed!) Press the ZONE button for the All LEDs will light up zone to control the Sivoia QED Controller. The zone’s entire column of zone LEDs will light Press here to when it has been assigned. Only one zone can be set to control any one Sivoia QED assign this zone to Controller. the Sivoia QED Note: To remove a zone from a Sivoia QED Controller: Put the Sivoia QED Controller Controller in setup mode, then press the ZONE button. Once the zone’s entire column of zone LEDs has turned OFF, the Sivoia QED Controller has been unassigned. 3. Exit setup mode. Press and hold the Open and Close buttons for about 3 seconds until the indicator LEDs stop cycling. 8

1

ON

3 4

Installation Instructions

1

6

ON

ON

Press and hold here for setup mode

5

ON

ON

1

4

ON

ON

1 2 3 4 5 6

3

ON

ON

5

2

ON

ON

For this window treatment controller address Set switches like this: Location:

1 ON

ON

Communication between Sivoia QED Controller and GRAFIK Eye Control Unit must be established prior to normal operation. Follow these steps: 1. Put the Sivoia QED Controller in setup mode (only one Sivoia QED Controller or Wallstation may be in setup mode at a time). Press and hold the Open and Close buttons for about 3 seconds, until the indicator LED(s) start to cycle.

1

1 ON

1

Installation Instructions


4 MUX 3 MUX 2 +V 1 COM

MUX COM MUX AC AC

Set Nightlight 1 2 3 4 5 6 ON

1

2

3

4

5

6

GRAFIK Control Link PELV (Class 2: USA) Wiring connections to GRAFIK Eye Control Units, G5000/G6000/G7000 Central Processors, Wallstations, and other Sivoia QED Controllers

7. For the GRAFIK control link, wiring must be done in a daisy-chain and 1-to-1 configuration. The GRAFIK control link terminal (gray connector) on the Sivoia QED Controller will accept up to two #18 AWG (1.0 mm2) wires. GRAFIK Eye 3000 Series System Wiring. Connect four #18 (1.0 mm2) twisted pair wires to the GRAFIK link terminal block. GRAFIK Eye 4000, GRAFIK 5000, GRAFIK 6000 and GRAFIK 7000 Series System Wiring. Connect two #18 (1.0 mm2) shielded, twisted pair wires to terminals 3 and 4 of the GRAFIK control link terminal block. Connect the drain as shown, but do not connect to Earth/Ground or Sivoia QED Controller. Two #12 AWG (2.5 mm2) power wires will not fit in the terminal blocks. Refer to the diagram shown to make the connections in the wallbox.

Sivoia QED EDU Link PELV (Class 2: USA) Wiring connections to Sivoia QED Electronic Drive Units

D PANEL

Drain

MUX MUX +V COM

2 #12 AWG (2.5 mm2) 2 #12 AWG (2.5 mm2)

TO APPLICABLE ZONE

TO APPLICABLE ZONE

TO APPLICABLE ZONE

TO APPLICABLE ZONE

TO APPLICABLE ZONE

TO APPLICABLE ZONE

Power

Line Voltage

1 2 3 4

SSA

To other GRAFIK Eye keypads

Comm Link (shielded)

HW/GRX Link

TO HOT/LIVE

TO NEUTRAL

SVQ-10-PNL

C 4 3 2 1

MUX MUX +V COM MUX COM MUX AC AC

A

5

B

Refer to the Sivoia QED Motorized Window Treatment System instruction sheets for more information on programming Sivoia QED Electronic Drive Units. Notes: 1. All Sivoia QED Motorized Window Treatments connected to the Sivoia QED Controller must be set up to operate as a single group. 2. Sivoia QED IR transmitters will not provide feedback to GRAFIK Eye Control Units or GRAFIK Eye Central Processors. 3. Use Sivoia QED keypads to control individual window treatments.

10

Terminal Block

1 #18 AWG (1.0 mm2)

GRAFIK Eye 4000, GRAFIK 5000, GRAFIK 6000 and GRAFIK 7000 Series System Wiring

GRAFIK Eye 3000 Series System Wiring Installation Instructions

to dimmed lighting loads

Control Links

Daisy-Chain Configuration For GRAFIK Systems Link

4 twisted pair, #18 AWG (1.0 mm2)

Wire Legend

DIST.

Back of SVC Unit

Rear View of Sivoia QED Controller

MUX MUX +V COM

8. Sivoia QED Electronic Drive Unit (EDU) Link Wiring. Each Sivoia QED Controller may be wired in a daisy chain, star, or ttap configuration to connect to up to 96 Sivoia QED EDUs. Total length of wire on this link should not exceed 4000 ft. (1220 m). Power (12 V ) is supplied to the Sivoia QED Controller from the Sivoia QED EDU. Connect one pair #18-22 AWG to terminals 1 and 2 on the Controller’s Sivoia QED EDU link terminal block (white). Connect two #24 AWG shielded, twisted wires to terminals 3 and 4 of the Sivoia QED link terminal block.

Comm 12 V on (Yello (Blue w) MUX ) MUX (Gray) 24 V~(Purple) 24 V~ (Red/Wh GND (Red) ite) (Yello w/Gre en)

6. LED Nightlight Option. The nightlight option can be switched on or off by setting DIP switch 6. When the nightlight option is on, the status LEDs will be dimly lit at all times.

6

Occupant Copy

Occupant Copy

7

Installation Instructions


Turn static files into dynamic content formats.

Create a flipbook