Object Installation Project number Date
: : Living Room : 1 : 20.06.2011
1
Lounge Example with Halogen
1.1
Description, Lounge Example with Halogen
1.1.1 Floor plan
N [m] 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0
0.0
Room data: W1 : 4.80 W2 : 3.60 W3 : 4.80 W4 : 3.60 W5 : ----W6 : ----Floor: ----Ceiling: ----Room height [m]: Height of reference plane [m]: Height of luminaire plane [m]:
0.5
1.0
1.5
2.0
2.5
3.0
Reflectance: 75.0 % 75.0 % 75.0 % 75.0 % --------55.0 % 88.0 % 2.70 0.75 2.70
3.5
4.0
4.5
[m] 1 : 50
Structural elements Pi : Pillar Tr : Partition Wo: Real working surface m : Virtual measuring area S : Skylight W : Picture Wi : Window DF : Door F : Furniture
www.DownlightsDirect.co.uk Tel: 01706 860011 Lounge Example
Page 1/4
Object Installation Project number Date
1.1
: : Living Room : 1 : 20.06.2011
Description, Lounge Example with Halogen
1.1.2 3D view, View 1
www.DownlightsDirect.co.uk Tel: 01706 860011 Lounge Example
Page 2/4
Object Installation Project number Date
: : Living Room : 1 : 20.06.2011
1
Lounge Example with Halogen
1.2
Summary, Lounge Example with Halogen
1.2.1 Result overview, Reference plane 1 N
[m] 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0.0
Illuminance [lx]
75
0.5
1.0
1.5
100
2.0
2.5
3.0
3.5
4.0
150
4.5
[m]
200
General Calculation algorithm used Height of evaluation surface Height of luminaire plane Maintenance factor
Average indirect fraction 0.75 m 2.70 m 0.80
Total luminous flux of all lamps Total power Total power per area (17.28 m²)
3217.80005 lm 300 W 17.36 W/m² (10.88 W/m²/100lx)
Illuminance Average illuminance Minimum illuminance Maximum illuminance Uniformity g1 Uniformity g2
Eav Emin Emax Emin/Em Emin/Emax
300
160 lx 76 lx 230 lx 1:2.1 (0.48) 1:3.03 (0.33)
Type No.\Make 3
6
ANSELL LIGHTING Order No. : ATLD Luminaire name : TWISTLOCK DOWNLIGHT + HALOPAR® 16 GU10 50W Equipment : 1 x OSRAM HALOPAR® 30 Aluminium 50 / 536.3 lm
www.DownlightsDirect.co.uk Tel: 01706 860011 Lounge Example
Page 3/4
Object Installation Project number Date
: : Living Room : 1 : 20.06.2011
1
Lounge Example with Halogen
1.3
Calculation results, Lounge Example with Halogen
1.3.1 Table, Reference plane 1 (E)
136 125 103
[m] 3.25
88
105
87
173 163 144 135 149
99
116
131 142 157
3.00
207 189 173 171 176 194 217 216 193 176 171 170 186
2.75
223 203 185 189 187 207 227 [230] 204 186 188 181 197
2.50
215 195 180 178 182 199 220 222 198 180 175 175 191 184 175 157 146 159 179 192 192 177 158 143 154 169
2.25
160 146 124 109 124 153 168 168 150 123 105 121 144 155 150 128
2.00
144 127 105
1.75
92
105 132 156 150 130 104
89
101 122 138 132 108 (76)
158 148 122 107 123 150 168 168 150 124 107 120 145 154 150 128 1.50 1.25
89
94
127 160 178 182 172 156 144 159 179 191 192 177 156 142 153 142 177 207 211 191 178 178 180 197 219 220 198 181 176 177
1.00
143 182 213 219 199 183 185 188 207 229 228 206 185 184 183
0.75
134 167 200 205 186 171 170 175 193 213 212 191 173 171 171
0.50
109 144 164 169 160 145 131 147 164 179 178 166 145 132 142
0.25
77
107 124 130 123 101 0.5
1.0
89 1.5
102 127 140 138 126 101 2.0
2.5
86
3.0
99 3.5
4.0
4.5
[m]
Illuminance [lx]
Height of the reference plane Average illuminance Minimum illuminance Maximum illuminance Uniformity g1 Uniformity g2
Eav Emin Emax Emin/Eav Emin/Emax
: 0.75 m : 160 lx : 76 lx : 230 lx : 1 : 2.10 (0.48) : 1 : 3.03 (0.33)
www.DownlightsDirect.co.uk Tel: 01706 860011 Lounge Example
Page 4/4