AIR CONDITIONER 2017/2018
ELITE INVERTER
N E W P R E M I U M I N V E RT E R
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. The contents of this catalogue are accurate as of January 2017. Due to printing considerations, the actual colours may vary slightly from those shown. All graphics are provided merely for the purpose of illustrating a point.
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
AC-ASIA-C-17
CONTENTS
KAI KEN BI
CONTENTS
THE PHILOSOPHY OF PANASONIC
02 - 03
20 - 21
KAI KEN BI
ECONAVI + INVERTER
04 - 05
22 - 34
#AIRTHATMOVESYOU DIRECT & INDIRECT COOLING
PRODUCT LINE-UP
At Panasonic, air conditioning is more than just about cool air. It is about how cool air is delivered to create a living space that brings you comfort when you need it most, takes care of your health and beautifies your homes and lives.
35
FEATURES EXPLANATION
06 - 07
SKY SERIES
KAI
KEN
36-37
AERO SERIES
RADIANT COOLING TECHNICAL EXPLANATION
10 - 11
38-41
DIRECT COOLING -SKY SERIES
nanoe-G
08 - 09
TECHNICAL EXPLANATION
BI 12 - 13
42 - 43
DIRECT COOLING -AERO SERIES
iAUTO-X & iAUTO TECHNICAL EXPLANATION
14 - 15
44 - 45
INDIRECT COOLING -SKY SERIES
FEATURES COMPARISON 46 - 47
MODEL LINE-UP
16 - 17
COMFORT
KAI
INDIRECT COOLING -AERO SERIES
Essential air conditioner functions that cool you in a more natural way. HEALTH
KEN
18 - 19
nanoe-G
Clean and fresh air that improves your health and wellbeing. BEAUTY
BI
02
02 04
Minimalist and modern air conditioners that beautify your home.
03
#AIRTHATMOVESYOU
#AIRTHATMOVESYOU
WHAT MOVES YOU? Is it the uplifting feeling of a cool gentle breeze? Or is it the exhilarating blast of cool air on a hot day?
Experience cooling comfort inspired by nature with Panasonic SKY Series and AERO Series.
# IRTHATMOVESYOU
For the perfect cooling experience, Panasonic Air Conditioners are designed to deliver comfort through Direct Cooling and Indirect Cooling. DIRECT COOLING Cools you fast with powerful and concentrated cool air at start up. SKY Series
AERO Series
INDIRECT COOLING Cools you gently after reaching the set temperature by cooling your surroundings. SKY Series
AERO Series
NEW
04
04
05
SKY SERIES
SKY SERIES
ELITE INVERTER
A I R CO N D I T I O N E R
SKYWING SKYWING is an innovative top flap that can better direct cool air towards the ceiling. The cool air then naturally glides along the ceiling surface, spreading throughout the room and down the walls. Heat is removed from the ceiling and walls, resulting in a feeling of even, all-round coolness – RADIANT COOLING.
CONTROLLED BY A MULTIDIRECTIONAL ARM
SKY STREAM DESIGN The SKY STREAM design highlights modern and minimalist lines, making it a luxurious complement to designer interior.
SKYWING can cool you in two ways : DIRECT COOLING
INDIRECT COOLING
MODERN & MINIMALIST LINES
SLIDING LED PANEL
BACKLIT SKY CONTROLLER
FAST COOLING
RADIANT COOLING
• Sleek and striking design. • Luxurious complement to designer interior.
• When switched on, the panel slides open to reveal its setting indicators.
• Backlit LED Screen. • Distinctive Sliding Cover. • Precise Temperature Control - Adjustable at 0.5°C.
SKYWING angles downwards to deliver powerful airflow at start up.
After reaching the set temperature, SKYWING angles upwards to direct cool air towards ceiling and walls, spreading cool air evenly throughout the room.
Please refer to Pg10-11
Please refer to Pg14-15
06
07
AERO SERIES
AERO SERIES
N E W P R E M I U M I N V E RT E R
AIR CONDITIONER AEROWINGS AEROWINGS are flexible twin flaps that can direct and concentrate airflow to cool an area effectively. These flaps are able to channel and concentrate cool air upwards, which showers down over the room for gentle and even coolness – SHOWER COOLING.
AEROWINGS WITH FLEXIBLE TWIN FLAPS
AERO SLIM DESIGN The AERO SLIM design features sleek lines and graceful curves while the lustrous pearl finishing and chrome escutcheon exude a sense of luxury. 236mm
199mm
2016
2017 AERO Series
AEROWINGS can cool you in two ways : DIRECT COOLING
INDIRECT COOLING
SLIM & SLEEK OUTLINE
LUSTROUS PEARL FINISHING
AERO CONTROLLER
FAST COOLING
SHOWER COOLING
• 37mm slimmer than previous models.
• Classy tone with a soft, pearly glow. • Chrome escutcheon with a sense of luxury.
• Precise Temperature Control - Adjustable at 0.5°C.
AEROWINGS twin flaps angle downwards to deliver concentrated airflow to cool you instantly at start up.
AEROWINGS angles upwards to spread cool air over a wider area, then showers down gently and evenly across the room after reaching the set temperature.
Please refer to Pg12-13
Please refer to Pg16-17
*AEROWINGS now available across all models. Design may vary according to models.
08
09
DIRECT COOLING - SKY SERIES
DIRECT COOLING - SKY SERIES ELITE INVERTER
DIRECT COOLING
A I R CO N D I T I O N E R
POWERFUL FAST COOLING Feel The Thrilling Cool Wind
At start up, SKYWING tilts down to bring you powerful and direct airflow to cool down instantly. Together with the high-powered Inverter compressor technology, P-TECh, SKY Series can achieve the desired temperature in the shortest time possible.
How DIRECT COOLING works in SKY Series:
1
CARES FOR YOUR ENJOYMENT
1
Powerful cool air is directed downwards at start up.
2
The steady airflow cools you down quickly.
2
P-TECh – THE POWER BEHIND FAST COOLING P-TECh
FAST COOLING AIRFLOW ASSESSMENT AIRFLOW SMOKE TEST
TEMPERATURE DISTRIBUTION TEST
• Cools You Down Instantly At Start Up
P-TECh enables the compressor to achieve maximum frequency in the shortest time from start up, giving you powerful cooling the moment the air conditioner is switched on. EQUENC Y MAX FR DASH TO
Compressor Frequency (Hz)
DASH & HIGH COMPRESSOR FREQUENCY HIGHEST FREQUENCY
2017 Panasonic P-TECh
2014 Panasonic
warmer
SKYWING directs airflow downwards and straight to room occupants for a fast cooling effect.
cooler
CONVENTIONAL COOLING
FAST COOLING
Cool air blows downwards and cools the room at a slow pace, resulting in uneven cooling. The edge of the room remains warm.
Powerful airflow cools rapidly. Room is evenly cooled.
Time (min.)
10
11
DIRECT COOLING - AERO SERIES
DIRECT COOLING - AERO SERIES N E W P R E M I U M I N V E RT E R
DIRECT COOLING
AIR CONDITIONER
POWERFUL FAST COOLING WITH CONCENTRATED AIRFLOW Be Greeted With A Blast Of Cool Air
AEROWINGS with twin flaps direct airflow downwards, delivering concentrated cool air the moment you switch on the air conditioner.
How DIRECT COOLING works in AERO Series:
1
Concentrated cool air is delivered straight to you.
2
The steady airflow cools you down quickly.
1
CARES FOR YOUR ENJOYMENT
2
P-TECh – THE POWER BEHIND FAST COOLING P-TECh
• Instant Relief From The Heat
P-TECh enables the compressor to achieve maximum frequency in the shortest time from start up, giving you powerful cooling the moment the air conditioner is switched on. EQUENC Y MAX FR DASH TO
Compressor Frequency (Hz)
DASH & HIGH COMPRESSOR FREQUENCY HIGHEST FREQUENCY
2017 Panasonic P-TECh
2014 Panasonic
FAST COOLING AIRFLOW ASSESSMENT AIRFLOW SMOKE TEST
TEMPERATURE DISTRIBUTION TEST
warmer
AEROWINGS directs airflow downwards and straight to room occupants for a fast cooling effect.
cooler
CONVENTIONAL COOLING
FAST COOLING
Cool air blows downwards and cools the room at a slow pace, resulting in uneven cooling. The edge of the room remains warm.
Concentrated airflow cools instantly. Room is evenly cooled.
Time (min.)
12
13
INDIRECT COOLING - SKY SERIES
INDIRECT COOLING - SKY SERIES ELITE INVERTER
INDIRECT COOLING
A I R CO N D I T I O N E R
RADIANT COOLING
Discover Natural All-Round Cooling RADIANT COOLING is inspired by caves, where the cool surfaces create an all-round cooling effect. After reaching the set temperature, SKYWING angles upwards to direct airflow towards ceiling and walls to remove the heat trapped in these surfaces for an overall cool environment. How RADIANT COOLING works:
1
Cool air is directed towards the ceiling.
2
Cool air spreads evenly throughout the room.
3
Heat trapped in ceiling and walls is removed.
4
Room is evenly cooled down.
2 1
CARES FOR YOUR WELLNESS
3 4
How RADIANT COOLING works:
RADIANT COOLING AIRFLOW ASSESSMENT AIRFLOW SMOKE TEST
TEMPERATURE DISTRIBUTION TEST
BOTTOM AIR INTAKE
• Cooling Effect Inspired By Caves That Prevents Excessive Cooling • Skin Stays Moist And Supple
14
warmer
Instead of blowing cold air directly onto people, SKYWING directs the airflow upwards to cool the ceiling and walls.
cooler
RADIANT COOLING SKYWING directs cool air upwards, removing heat from ceiling and walls for an all-round cooling effect.
Hot air is drawn in from the bottom, and cool air is discharged from the top to facilitate the even distribution of cool air.
15
INDIRECT COOLING - AERO SERIES
INDIRECT COOLING - AERO SERIES N E W P R E M I U M I N V E RT E R
INDIRECT COOLING
AIR CONDITIONER
SHOWER COOLING
Feel Gentle Cool Like Morning Dew SHOWER COOLING is the feeling that gently washes over you like a cool morning. After reaching the set temperature, AEROWINGS directs airflow upwards to spread cool air evenly across the room, and showers down for endless comfort.
How SHOWER COOLING works:
1 2
CARES FOR YOUR COMFORT
1
Cool air is directed upwards.
2
Cool air spreads evenly and showers down.
3
Room is evenly cooled down.
3
SHOWER COOLING AIRFLOW ASSESSMENT AIRFLOW SMOKE TEST
TEMPERATURE DISTRIBUTION TEST
TOP AIR INTAKE
• Prevents Overcooling From Direct Airflow
warmer
Instead of blowing cold air directly onto people, AEROWINGS directs airflow upwards over a wider area, then showers down gently and evenly across the room.
16
cooler
SHOWER COOLING AEROWINGS directs cool air further and higher towards the ceiling to avoid direct cooling.
Hot air is drawn in from the top, and cool air is discharged from the bottom to facilitate cool air showering down over the entire area.
17
AIR PURIFICATION SYSTEM
AIR PURIFICATION SYSTEM
AIR PURIFICATION SYSTEM
Breathe Fresh & Clean For overall wellbeing, Panasonic Air Conditioners feature an advanced air purification system called nanoe-G, which releases active ions that attach to particles as small as PM2.5. How nanoe-G works:
1
AIRBORNE
Airborne particles:
PM2.5
CARES FOR YOUR WELLBEING
Bacteria
Viruses
Odour Particle
nanoe-G
2
Decompose and Remove Odour
(Up to 99%*1 *2)
Removes airborne particles, even down to PM2.5*1. These particles*2 include bacteria, viruses and mould. Please refer to Pg38-39
Remark: * 3 trillion is the simulated number of nanoe-G fine particles under the mentioned conditions. Actual measured nanoe-G fine particles at the centre of the room (13m2):100k/cc calculated number of nanoe-G fine particles in the entire room assuming they are evenly distributed.
ADHESIVE
3
DEACTIVATES ADHESIVE PARTICLES & DEODORISES ADHESIVE ODOURS
IN-FILTER DEACTIVATION
(Up to 99%*3)
Deactivates bacteria and viruses trapped in the filter.
Deactivates adhesive micro-organisms and deodorises adhesive odours. Inhibits mould growth that settles on surfaces around you. *3
featuring
fine particles released from the generator.
IN-FILTER DEACTIVATION
2
REMOVES AIRBORNE PARTICLES
*1 & *2
3 trillion*
nanoe-G
airborne particles
1
And Cleaner Air
3
nanoe-G catches Mechanism
Strike Odour Particles
• Fresher
Natural Ion Wind spreads nanoe-G fine particles that are released from the nanoe-G generator.
Mould
(Up to 99%*4)
*4
Please refer to Pg41
Please refer to Pg40
DUST SENSOR
*Only applicable to SKY Series.
SKY Series also features an additional DUST SENSOR, which constantly monitors air quality and automatically activates nanoe-G when a high level of particle concentration is detected.
18
19
ECONAVI + INVERTER
ECONAVI + INVERTER
ENERGY SAVINGS ECONAVI and INVERTER work together to alternate speed frequency. Enjoy energy savings while staying comfortable throughout the day.
Enjoy Ultimate Comfort With Energy Savings ECONAVI has two sensors – Human Activity Sensor and Sunlight Sensor. Together, they monitor human location, movement, absence, and sunlight intensity to use energy more efficiently. ECONAVI SAVES YOU ENERGY BECAUSE IT SENSES: Where you are. AREA SEARCH
HUMAN ACTIVITY SENSOR
SUNLIGHT SENSOR
When you leave the room.
CARES FOR YOUR PEACE OF MIND
ABSENCE DETECTION
SUNLIGHT DETECTION
When you are less active.
HUMAN ACTIVITY DETECTION
ACTIVITY DETECTION
SUNLIGHT DETECTION
TEMPERATURE WAVE
Whether it’s a sunny day or at night. Adapts rhythmic temperature control after detecting low activity level.
*Applicable to PREMIUM INVERTER only.
Precise Temperature Control INVERTER prevents wasteful energy consumption by varying the compressor rotation speed to maintain the set temperature. • Stay Comfortable While Saving Energy
NON-INVERTER
Room Big temperature temperature fluctuations
CONSTANT COMFORT Precise temperature control with a wide power output range enables an INVERTER air conditioner to meet different room occupancy levels – thus ensuring constant comfort.
MAXIMUM POWER
INVERTER Little temperature Room temperature fluctuations
Compressor rotation speed: HIGH
Control • Save on Electricity Bills
Legend:
ON
OFF
When required, the unit operates at full power.
ON
OFF
ON Time
Output Power Remark: Energy is wasted by switching the compressor Temperature ON and OFF to maintain the set temperature.
A conventional non-INVERTER air conditioner can only operate at a constant speed which is too powerful to maintain the set temperature. Thus, it switches the compressor on and off repeatedly. This results in wider temperature fluctuations leading to wasteful consumption of energy.
20
Output power
• Precise Temperature
Output power
Set temperature
Power: 4.20kW
Set temperature
MEDIUM POWER
ON
Legend:
Normal condition
Time
Power: 3.67kW
Output Power Remark: Saves energy by varying the rotation speed of the Temperature compressor to maintain the set temperature.
The Panasonic INVERTER air conditioner varies the rotation speed of the compressor, providing a precise method of maintaining the set temperature. Thus, Panasonic INVERTER air conditioners give you exceptional energy saving performance while ensuring you stay comfortable at all times.
MINIMUM POWER Compressor rotation speed: SLOW When not required, the unit operates at low power to save energy.
Power: 0.92kW Graph shows the 1.5HP PREMIUM INVERTER model’s wide power output range during cooling.
21
PRODUCT LINE-UP
WALL-MOUNTED :
PRODUCT LINE-UP
BACKLIT SKY CONTROLLER
Single-Split Type
ELITE
Enjoy innovative design at your fingertips with the new stylish and sleek Backlit Sky Controller.
CS-VS10SKH | CS-VS13SKH | CS-VS18SKH
Wireless
Wired (Optional)
SPECIFICATIONS
Cooling
MODEL
Cooling Capacity EER
Electrical Data
(50Hz)
(min-max)
kW
(min-max)
Btu/h
(min-max)
Btu/hW
Noise Level
CS-VS13SKH
CS-VS18SKH
[CU-VS10SKH]
[CU-VS13SKH]
[CU-VS18SKH]
2.85 (0.84-3.28)
3.66 (0.92-4.20)
5.20 (1.10-5.80)
9,720 (2,860-11,200)
12,500 (3,140-14,300)
17,700 (3,750-19,800)
13.16 (12.08-12.12)
12.21 (12.93-11.72)
220 - 240
220 - 240
220 - 240
Current
A
3.5 - 3.2
4.6 - 4.2
7.0 - 6.4
Power Input (min-max)
W
720 (225-900)
950 (260-1,180)
1,450 (290-1,690)
L/h
1.7
2.1
2.9
(Pt/h)
3.6
4.4
6.1
Indoor
m3/min (ft3/min)
10.1 (355)
12.0 (425)
13.4 (475)
Outdoor
m3/min (ft3/min)
21.6 (760) - 22.9 (810)
29.0 (1,020) - 29.6 (1,040)
34.9 (1,230) - 34.9 (1,230)
Indoor (H / L / Q-Lo)
dB (A)
36/25/18
41/27/19
46/36/31
Outdoor (H)
dB (A)
(47) - (48)
(48) - (49)
(49) - (50)
Width
mm
318 (511)
318 (542)
318 (619)
inch
12-17/32 (20-1/8)
12-17/32 (21-11/32)
12-17/32 (24-3/8)
mm
950 (650)
950 (780)
950 (824)
inch
37-13/32 (25-19/32)
37-13/32 (30-23/32)
37-13/32 (32-15/32)
mm
280 (230)
280 (289)
280 (299)
inch
11-1/32 (9-1/16)
11-1/32 (11-13/32)
11-1/32 (11-25/32)
Indoor
kg (lb)
13 (29)
13 (29)
13 (29)
Outdoor
kg (lb)
21 (46)
29 (64)
33 (73)
mm
ø 6.35
ø 6.35
ø 6.35
Liquid Side Refrigerant Pipe Diameter Gas Side
Pipe Extension
CS-VS10SKH
13.5 (12.71-12.44)
Depth
Net Weight
): Outdoor Unit
V
Height
Dimensions
(
Voltage
Moisture Removal
Air Circulation
With fast access to key operations and a smooth gliding cover revealing more options, controlling your settings has become simple and intuitive.
inch
1/4
1/4
1/4
mm
ø 9.52
ø 12.70
ø 12.70
inch
3/8
1/2
1/2
Chargeless Pipe Length
m
7.5
7.5
10
Maximum Pipe Length
m
15
15
30
Maximum Elevation Length
m
5
5
20
Additional Refrigerant Gas**
g/m
Power Supply
15
15
15
Indoor
Indoor
Indoor
Caution For CS-VS10/VS13/VS18SKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
With a width of 58.9mm and a length of 164.7mm, the Sky Controller fits comfortably into your hand.
1
WIDTH 58.9mm (CS-VS10SKH)
HEIGHT 22.0mm
COOLING MODELS
LENGTH 164.7mm
(Random)
Backlit LED screen lets you view operations status in the dark.
2 Power Button. 3
4
DUST SENSOR
RADIANT COOLING
CS-VS10SKH CS-VS13SKH
iCOMFORT lets you come home to FAST COOLING. Then enjoy continuous comfort with RADIANT COOLING which avoids direct cooling. Press up or down to set the temperature.
CS-VS18SKH
(Optional)
1
OUTDOOR
2
3
4
5 5
Toggles between RADIANT COOLING (INDIRECT) and Fast Cooling (DIRECT). *The term “RADIANT” was replaced based on running change effective for new 2017 production.
6
Activates the nanoe-G function even when the air conditioner is switched off.
7
Set the airflow.
8
Adjusts the fan speed.
9
Toggles between COOL and DRY setting mode.
6
7
8 10
9
CU-VS10SKH
11 12
CU-VS13SKH
CU-VS18SKH
10 Delays off timer with temperature
control for better sleep.
11 Set the 24-hour ON & OFF Timer or
24-hour Dual ON & OFF Timer.
12 Set the actual time
[hour and minute].
Wireless Applicable to ELITE INVERTER
22
23
PRODUCT LINE-UP
WALL-MOUNTED :
PREMIUM
PRODUCT LINE-UP
Single-Split Type
EASY-TO-USE REMOTE CONTROLLER
Wireless
CS-S10TKH | CS-S13TKH
Wired (Optional)
Wireless
CS-S18TKH | CS-S24TKH | CS-S28TKH
Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.
Wired (Optional)
SPECIFICATIONS
Cooling
MODEL
Cooling Capacity EER
Electrical Data
(50Hz)
Noise Level
CS-S24TKH
CS-S28TKH
[CU-S18TKH]
[CU-S24TKH]
[CU-S28TKH]
kW
2.85 (0.84-3.28)
3.67 (0.92-4.20)
5.30 (1.10-6.00)
6.25 (1.12-7.10)
7.10 (1.15-8.50)
9,720 (2,860-11,200)
12,500 (3,140-14,300)
18,100 (3,750-20,500)
21,300 (3,820-24,200)
24,200 (3,920-29,000)
(min-max)
Btu/hW
13.32 (12.71-12.17)
12.38 (12.08-11.92)
12.57 (12.93-12.06)
11.33 (11.94-11.00)
11.92 (11.20-10.74)
Voltage
V
220-240
220-240
220-240
220-240
220-240
Current
A
3.6-3.3
5.1-4.6
7.0-6.4
8.8-8.2
9.6-9.0
Power Input (min-max)
W
730 (225-920)
1,010 (260-1,200)
1,440 (290-1,700)
1,880 (320-2,200)
2,030 (350-2,700)
L/h
1.7
2.1
2.9
3.5
4.1
(Pt/h)
3.6
4.4
6.1
7.4
8.7
11.1 (390)
19.6 (690)
20.2 (715)
21.7 (765)
m3/min (ft3/min)
10.5 (370)
Outdoor
m3/min (ft3/min)
26.5 (940)-28.1 (990)
30.6 (1,080)-31.2 (1,100) 35.0 (1,235)-36.2 (1,280) 47.0 (1,660)-47.0 (1,660) 48.6 (1,715)-51.9 (1,830)
Indoor (H / L / Q-Lo)
dB (A)
36/26/23
38/28/25
44/32/29
45/34/31
Outdoor (H)
dB (A)
46-47
47-48
49-50
51-52
52-53
mm
295 (511)
295 (542)
302 (619)
302 (695)
302 (795)
inch
11-5/8 (20-1/8)
11-5/8 (21-11/32)
11-29/32 (24-3/8)
11-29/32 (27-3/8)
11-29/32 (31-5/16)
Width
mm
919 (650)
919 (780)
1120 (824)
1120 (875)
1120 (875)
inch
36-3/16 (25-19/32)
36-3/16 (30-23/32)
44-1/8 (32-15/32)
44-1/8 (34-15/32)
44-1/8 (34-15/32)
mm
199 (230)
199 (289)
241 (299)
241 (320)
241 (320)
inch
7-27/32 (9-1/16)
7-27/32 (11-13/32)
9-1/2 (11-25/32)
9-1/2 (12-5/8)
9-1/2 (12-5/8)
kg (lb)
9 (20)
9 (20)
12 (26)
12 (26)
12 (26)
Outdoor
kg (lb)
20 (44)
27 (60)
34 (75)
40 (88)
57 (126)
mm
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
inch
1/4
1/4
1/4
1/4
1/4
mm
ø 9.52
ø 12.70
ø 12.70
ø 15.88
ø 15.88
inch
3/8
1/2
1/2
5/8
5/8
Chargeless Pipe Length
m
7.5
7.5
10
10
10
Maximum Pipe Length
m
15
15
30
20
30
Maximum Elevation Length
m
5
5
20
15
20
Additional Refrigerant Gas**
g/m
15
15
15
20
30
Indoor
Indoor
Indoor
Indoor
Outdoor
Refrigerant Pipe Diameter Gas Side
Power Supply
Caution For CS-S10/S13/S18/S24/S28TKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
2
Come home to FAST COOLING. Then enjoy continuous comfort with SHOWER COOLING which avoids direct cooling.
3
ECONAVI monitors sunlight intensity, human movement, activity levels and human absence to detect and reduce energy waste.
4
5
6
COOLING MODELS 1
Activates the nanoe-G function even when the air conditioner is switched off.
8
Set the airflow.
9
Adjusts the fan speed.
2
3 5
6 7
Toggles between iAUTO-X, COOL and DRY setting mode. Delays off timer with temperature control for better sleep.
C
4 (Random)
Press up or down to set the temperature.
7
47/37/34
Indoor
Liquid Side
Pipe Extension
CS-S18TKH
[CU-S13TKH]
Btu/h
Depth
Net Weight
CS-S13TKH
[CU-S10TKH] (min-max)
Height
Dimensions
CS-S10TKH
Indoor
LCD display for an easy overview of the operation status.
): Outdoor Unit
(min-max)
Moisture Removal
Air Circulation
(
1
8 CS-S10TKH CS-S13TKH
10
CS-S24TKH
9 11
(Optional)
12
OUTDOOR
10 Quiet function allows you
to sleep comfortably at night. CU-S10TKH
Wireless Applicable to PREMIUM INVERTER
11 Set the 24-hour ON & OFF Timer or
24-hour Dual ON & OFF Timer. 12 Set the actual time
(hour and minute). CU-S13TKH
DUAL TIMER
CU-S18TKH
DUAL TIMER FOR 2 ON AND OFF TIMES PER DAY For convenience, the dual timer repeats everyday until you cancel it. Select ON or OFF Timer.
CU-S24TKH
1
2
1
Cancel
2
Cancel
Set the time. TIMER CU-S28TKH
24
25
CS-S18TKH CS-S28TKH
PRODUCT LINE-UP
WALL-MOUNTED : STANDARD
PRODUCT LINE-UP
Single-Split Type
EASY-TO-USE REMOTE CONTROLLER
Wireless
CS-PS9TKH | CS-PS12TKH
Wired (Optional)
Wireless
CS-PS18TKH | CS-PS24TKH
Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.
Wired (Optional)
SPECIFICATIONS MODEL
Cooling Capacity EER
Electrical Data
(50Hz)
2.64 (0.84-2.73)
3.51 (0.92-3.65)
5.00 (1.10-5.43)
6.01 (1.12-6.80)
9,000 (2,860-9,310)
12,000 (3,140-12,400)
17,100 (3,750-18,500)
20,500 (3,820-23,200)
(min-max)
Btu/hW
11.54 (12.17-11.22)
11.65 (11.63-11.27)
11.63 (12.50-10.82)
11.08 (11.58-10.45)
Voltage
V
220-240
220-240
220-240
220-240
Current
A
3.9-3.6
5.1-4.7
7.0-6.4
8.8-8.2
W
780 (235-830)
1,030 (270-1,100)
1,470 (300-1,710)
1,850 (330-2,220)
L/h
1.6
2.0
2.8
3.3
(Pt/h)
3.4
4.2
5.9
7.0
Indoor
m3/min (ft3/min)
10.0 (355)
10.8 (380)
19.6 (690)
20.2 (715)
Outdoor
m3/min (ft3/min)
26.5 (940)-28.1 (990)
30.6 (1,080)-31.2 (1,100)
35.0 (1,235)-36.2 (1,280)
47.0 (1,660)-47.0 (1,660)
Indoor (H / L / Q-Lo)
dB (A)
36/26/23
38/28/25
44/32/29
45/36/33
Outdoor (H)
dB (A)
46-47
47-48
49-50
49-50
Width
mm
290 (511)
290 (542)
302 (619)
302 (695)
inch
11-7/16 (20-1/8)
11-7/16 (21-11/32)
11-29/32 (24-3/8)
11-29/32 (27-3/8)
mm
799 (650)
799 (780)
1,102 (824)
1,102 (875)
inch
31-15/32 (25-19/32)
31-15/32 (30-23/32)
43-13/32 (32-15/32)
43-13/32 (34-15/32)
mm
197 (230)
197 (289)
244 (299)
244 (320)
inch
7-25/32 (9-1/16)
7-25/32 (11-13/32)
9-5/8 (11-25/32)
9-5/8 (12-5/8)
Indoor
kg (lb)
8 (18)
8 (18)
12 (26)
12 (26)
Outdoor
kg (lb)
19 (42)
27 (60)
32 (71)
40 (88)
mm
ø 6.35
ø 6.35
ø 6.35
ø 6.35
inch
1/4
1/4
1/4
1/4
mm
ø 9.52
ø 12.70
ø 12.70
ø 15.88 5/8
Liquid Side Refrigerant Pipe Diameter Gas Side
Pipe Extension
[CU-PS24TKH]
kW
Depth
Net Weight
CS-PS24TKH
[CU-PS18TKH]
Btu/h
Height
Dimensions
CS-PS18TKH
[CU-PS12TKH]
(min-max)
Moisture Removal
Noise Level
CS-PS12TKH
[CU-PS9TKH]
(min-max)
Power Input (min-max)
Air Circulation
CS-PS9TKH
inch
3/8
1/2
1/2
Chargeless Pipe Length
m
7.5
7.5
7.5
10
Maximum Pipe Length
m
15
15
15
20
Maximum Elevation Length
m
5
5
5
15
Additional Refrigerant Gas**
g/m
15
15
15
20
Indoor
Indoor
Indoor
Indoor
Power Supply
1
LCD display for an easy overview of the operation status.
2
Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.
3
Quiet function allows you to sleep comfortably at night.
4
Adjusts the fan speed.
5
Press up or down to set the temperature.
COOLING MODELS 1
2
3 5
6
Toggles between iAUTO, COOL and DRY setting mode.
7
Delays off timer with temperature control for better sleep.
8
Set the airflow.
9
Set the 24-hour ON & OFF Timer or 24-hour Dual ON & OFF Timer.
6
4
7
8
(Random)
CS-PS24TKH
CS-PS9TKH CS-PS12TKH CS-PS18TKH
(Optional)
9 10
OUTDOOR
10 Set the actual time (hour and minute).
Wireless Applicable to STANDARD INVERTER
CU-PS9TKH
CU-PS12TKH
TO SET THE TIMER To turn the unit ON or OFF at a preset time. 1
2
CU-PS18TKH
3
TIMER
ON
1
Caution For CS-PS9/PS12/PS18/PS24TKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. *When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OFF
SET
2
33 CANCEL CAN CEL
Select ON or OFF Timer.
Set the time.
CU-PS24TKH
Example: OFF at 22:00 OFF
2
Confirm. TIMER
26
SET
27
PRODUCT LINE-UP
WALL-MOUNTED : DELUXE
PRODUCT LINE-UP
Multi-Split Type
INVERTER DUAL-SPLIT MODEL
INDOOR MODEL
(50Hz)
Operation
Wireless
Cooling Capacity
COOLING MODELS C
CS-S9TKZW + CS-S12TKZW
Btu/h kW
Electrical Data
Voltage
Sound Pressure Level
Indoor (H/L)
Moisture Removal
Wired (Optional)
Air Circulation (Indoor) Fan Output
(Random)
(Optional)
Dimensions
OUTDOOR MODEL
CU-2S18PKZ
Port A
2.8
or Either unit
3.2
Port B
2.8
or Either unit
3.2
2-Room
CS-MS15TKZ
CS-S18TKZW
1-Unit
1-Unit
1-Unit
CS-S24TKZW 1-Unit
9,550
10,900
13,600
17,100
20,500
2.80
3.20
4.00
5.00
6.00
220-240
220-240
220-240
220-240
220-240 48/ 39
40 / 29
44 / 32
45 / 32
47 / 38
L/h
1.6
1.8
2.3
2.7
3.3
m³/min.
9.8
11.0
12.8
19.3
20.3
ft3/min.
345
390
450
680
715
W
40
40
40
30
30
mm
295
295
295
302
302
Width
mm
919
919
919
1,120
1,120
Depth
mm
199
199
199
241
241
9
9
9
12
12
ø 6.35
ø 6.35
ø 6.35
ø 6.35
ø 6.35
kg
Refrigerant Pipe Diameter Power Supply
dB (A)
CS-S12TKZW
1-Unit
Height
Net Weight (Indoor)
Indoor Units: Possible Combination Patterns ( Must be within capacity range )
V
CS-S9TKZW
Liquid Side
mm
Gas Side
mm
P
ø 9.52
ø 9.52
ø 9.52
ø 9.52
ø 12.70
Outdoor
Outdoor
Outdoor
Outdoor
Outdoor
OUTDOOR • It is possible to have a combination of wall-mounted models (CS-S9, S12TKZW) for the (CU-2S18PKZ) Outdoor Unit Ports. • A minimum of 2 indoor units must be connected.
DUAL-SPLIT MODEL
TRIPLE-SPLIT MODEL
(50Hz)
CU-2S18PKZ
CU-3S27KKZ
(min-max)
Btu/h
17,100 (5,120-20,500)
25,600 (9,550-30,700)
(min-max)
kW
(min-max)
Btu/hW
(min-max)
W/W
MODEL Cooling Capacity
INVERTER TRIPLE-SPLIT MODEL
EER
Electrical Data
COOLING MODELS
CS-S9TKZW + CS-S12TKZW + CS-MS15TKZ + CS-S18TKZW + CS-S24TKZW
220-240
Running Current
A
6.60-6.10
10.1-9.2
W
1,400 (250~1,750)
2,060 (520~2,830)
Outdoor (H)
3-Room
2.8 or 3.2 or 4.0 or 5.0
or
6.0
Port B
2.8 or 3.2 or 4.0 or 5.0
or
6.0
Port C
2.8 or 3.2 or 4.0 or
or
6.0
5.0
15.2
6.6
10.1 1,300
W
40
60
Height
mm
619
795
Width
mm
824 (+70)
875 (+95)
Depth
mm
299
320
kg
37
68
m
20
30
1-Room
20
25
Total
30
60
Maximum Elevation Length
m
10
15
Additional Refrigerant Gas*
g/m
15
20
Chargeless Pipe Length
Port A
12
900
Net Weight (Outdoor)
Indoor Units: Possible Combination Patterns ( Must be within capacity range )
49
A A
Pipe Extension**
CU-3S27KKZ
49
W
(Optional)
MODEL
dB (A)
Compressor Output
Dimensions
OUTDOOR
3.64 (5.38-3.18)
Starting Current
Wired (Optional) (Random)
3.57 (6.00-3.43) 220-240
Fan Output
C
12.43 (18.37-10.85)
V
Maximum Current
Wireless
7.50 (2.80-9.00)
12.21 (20.48-11.71)
Voltage
Power Input (min-max) Sound Pressure Level
5.00 (1.50-6.00)
Maximum Pipe Length
* When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.
• It is possible to have a combination of wall-mounted models (CS-S9, S12, S18, S24TKZW, CS-MS15TKZ) for the (CU-3S27KKZ) Outdoor Unit Ports. • A minimum of 2 indoor units must be connected.
28
29
PRODUCT LINE-UP
WALL-MOUNTED :
DELUXE
PRODUCT LINE-UP
WALL-MOUNTED : DELUXE Non-INVERTER Single-Split Type
Multi-Split Type
INVERTER DUAL-SPLIT MODEL (CU-2S18PKZ)
1-Room 2-Room
A
B
Total
min ~ max
Rated
min ~ max
220V
240V
2.8
2.8
2.80
—
2.80
1.10 ~ 3.50
750
220 ~ 1,000
3.7
3.4
1.6
3.2
3.2
3.20
—
3.20
1.10 ~ 4.00
920
220 ~ 1,220
4.5
4.2
1.8
2.8 + 2.8
5.6
2.40
2.40
4.80
1.50 ~ 5.80
1,310
250 ~ 1,690
6.4
5.9
1.5 + 1.5
2.8 + 3.2
6.0
2.30
2.70
5.00
1.50 ~ 5.90
1,490
250 ~ 1,710
7.3
6.8
1.5 + 1.6
3.2 + 3.2
6.4
2.50
2.50
5.00
1.50 ~ 6.00
1,400
250 ~ 1,750
6.6
6.1
1.5 + 1.5
Cooling Capacity (kW)
Total
Power Input (W)
INVERTER TRIPLE-SPLIT MODEL (CU-3S27KKZ) Indoor Unit Combination
1-Room
2-Room
3-Room
Current (A) [50Hz]
Moisture Removal L/h
Indoor Unit Combination
Total
A
B
C
Current (A) [50Hz]
Total
min ~ max
Rated
min ~ max
220V
240V
Moisture Removal L/h
700
380 ~ 890
3.7
3.4
1.6
Cooling Capacity (kW)
Power Input (W)
2.8
2.8
2.80
2.80
1.70 ~ 3.40
3.2
3.2
3.20
3.20
1.70 ~ 4.00
800
380 ~ 1,200
4.2
3.9
1.8
4.0
4.0
4.00
4.00
1.70 ~ 4.80
1,180
380 ~ 1,480
6.0
5.5
2.3
5.0
5.0
5.00
5.00
1.90 ~ 5.80
1,460
400 ~ 1,890
7.3
6.7
2.7
6.0
6.0
6.00
6.00
1.90 ~ 6.20
1,920
400 ~ 2,070
9.3
8.6
3.3
2.8 + 2.8
5.6
2.80
2.80
5.60
1.70 ~ 6.70
1,750
420 ~ 2,340
8.6
7.9
1.6 + 1.6
2.8 + 3.2
6.0
2.80
3.20
6.00
1.70 ~ 6.70
2,010
420 ~ 2,340
9.8
9.0
1.6 + 1.8
2.8 + 4.0
6.8
2.80
4.00
6.80
2.50 ~ 7.60
2,420
550 ~ 2,990
11.8
10.8
1.6 + 2.3
2.8 + 5.0
7.8
2.69
4.81
7.50
2.70 ~ 8.00
2,810
530 ~ 2,980
13.7
12.6
1.6 + 2.6
2.8 + 6.0
8.8
2.39
5.11
7.50
2.70 ~ 8.00
2,810
530 ~ 2,980
13.7
12.6
1.5 + 2.8
3.2 + 3.2
6.4
3.20
3.20
6.40
2.30 ~ 7.40
2,290
570 ~ 3,010
11.2
10.3
1.8 + 1.8
3.2 + 4.0
7.2
3.20
4.00
7.20
2.50 ~ 7.70
2,770
550 ~ 2,990
13.5
12.4
1.8 + 2.3
3.2 + 5.0
8.2
2.93
4.57
7.50
2.80 ~ 8.00
2,760
530 ~ 2,970
13.5
12.4
1.7 + 2.5
3.2 + 6.0
9.2
2.61
4.89
7.50
2.80 ~ 8.00
2,760
530 ~ 2,970
13.5
12.4
1.6 + 2.7
4.0 + 4.0
8.0
3.75
3.75
7.50
2.70 ~ 7.90
2,870
540 ~ 2,980
14.0
12.9
2.2 + 2.2
4.0 + 5.0
9.0
3.33
4.17
7.50
2.80 ~ 8.10
2,600
530 ~ 2,970
12.7
11.6
1.9 + 2.4
4.0 + 6.0
10.0
3.00
4.50
7.50
2.80 ~ 8.10
2,600
530 ~ 2,970
12.7
11.6
1.7 + 2.5
5.0 + 5.0
10.0
3.75
3.75
7.50
2.90 ~ 8.30
2,440
520 ~ 2,970
11.9
10.9
2.2 + 2.2
5.0 + 6.0
11.0
3.41
4.09
7.50
2.90 ~ 8.30
2,440
520 ~ 2,970
11.9
10.9
2.0 + 2.3
CS-C9RKH | CS-C12RKH
Wireless
COOLING MODELS
CS-C18RKH | CS-C24RKH | CS-C28RKH
CS-C12RKH
SPECIFICATIONS MODEL
(50Hz)
CS-C28RKH
[CU-C24RKH]
[CU-C28RKH]
2.65 - 2.70
3.52 - 3.57
5.40 - 5.40
7.03 - 7.03
7.90 - 8.00
9,040 - 9,210
12,000 - 12,200
18,400 - 18,400
24,000 - 24,000
26,900 - 27,300
Btu/hW
9.89 - 9.89
10.51 - 9.95
10.21 - 9.72
220 - 240
220 - 240
220 - 240
220 - 240
Current
A
3.8 - 3.7
5.2 - 5.2
8.5 - 8.4
11.0 - 11.1
12.6 - 12.0
W
800 - 835
1,110 - 1,150
1,750 - 1,850
2,350 - 2,470
2,720 - 2,760
L/h
1.6
2.1
2.9
4.0
4.7
(Pt/h)
3.4
4.4
6.1
8.5
9.9
16.4 (579)
18.2 (642)
20.2 (713)
Indoor
m3/min (ft3/min)
9.8 (346)
10.8 (381)
Outdoor
m3/min (ft3/min)
30.3 (1,070)-31.3 (1,100) 55.0 (1,940)-57.0 (2,010) 48.5 (1,710)-50.5 (1,780)
28.8 (1,020)-29.6 (1,040)
22.0 (780)-23.6 (830)
Indoor (H / L)
dB (A)
36/26
39/29
43/37
46/40
49/44
Outdoor (H)
dB (A)
(46) - (47)
(48) - (49)
(53) - (54)
(54) - (55)
(55) - (56)
3.75
3.75
7.50
2.90 ~ 8.30
2,440
520 ~ 2,970
11.9
10.9
2.2 + 2.2
8.4
2.50
2.50
2.50
7.50
2.40 ~ 7.90
2,740
580 ~ 2,840
13.4
12.3
1.5 + 1.5 + 1.5
2.8 + 2.8 + 3.2
8.8
2.39
2.39
2.72
7.50
2.40 ~ 8.00
2,690
580 ~ 2,850
13.1
12.1
1.5 + 1.5 + 1.6
2.8 + 2.8 + 4.0
9.6
2.19
2.19
3.12
7.50
2.60 ~ 8.40
2,490
600 ~ 2,930
12.2
11.2
1.4 + 1.4 + 1.8
2.8 + 2.8 + 5.0
10.6
1.98
1.98
3.54
7.50
2.80 ~ 8.80
2,250
600 ~ 3,010
11.0
10.1
1.3 + 1.3 + 2.0
2.8 + 2.8 + 6.0
11.6
1.81
1.81
3.88
7.50
2.80 ~ 8.80
2,250
600 ~ 3,010
11.0
10.1
1.2 + 1.2 + 2.3
2.8 + 3.2 + 3.2
9.2
2.28
2.61
2.61
7.50
2.40 ~ 8.00
2,690
580 ~ 2,860
13.1
12.1
1.5 + 1.6 + 1.6
2.8 + 3.2 + 4.0
10.0
2.10
2.40
3.00
7.50
2.60 ~ 8.40
2,450
600 ~ 2,930
12.0
11.0
1.4 + 1.5 + 1.7
2.8 + 3.2 + 5.0
11.0
1.91
2.18
3.41
7.50
2.80 ~ 8.80
2,250
600 ~ 3,020
11.0
10.1
1.2 + 1.4 + 2.0
2.8 + 3.2 + 6.0
12.0
1.75
2.00
3.75
7.50
2.80 ~ 8.80
2,250
600 ~ 3,020
11.0
10.1
1.1 + 1.3 + 2.2
2.8 + 4.0 + 4.0
10.8
1.94
2.78
2.78
7.50
2.70 ~ 8.70
2,290
600 ~ 3,000
11.2
10.3
1.3 + 1.6 + 1.6
Chargeless Pipe Length
2.8 + 4.0 + 5.0
11.8
1.78
2.54
3.18
7.50
2.80 ~ 9.00
2,170
580 ~ 3,050
10.6
9.7
1.1 + 1.6 + 1.8
2.8 + 4.0 + 6.0
12.8
1.64
2.34
3.52
7.50
2.80 ~ 9.00
2,170
580 ~ 3,050
10.6
9.7
1.0 + 1.5 + 2.0
2.8 + 5.0 + 5.0
12.8
1.64
2.93
2.93
7.50
2.80 ~ 9.00
2,070
520 ~ 2,830
10.1
9.3
1.0 + 1.7 + 1.7
3.2 + 3.2 + 3.2
9.6
2.50
2.50
2.50
7.50
2.40 ~ 8.00
2,650
590 ~ 2,860
13.0
11.9
1.5 + 1.5 + 1.5
3.2 + 3.2 + 4.0
10.4
2.31
2.31
2.88
7.50
2.60 ~ 8.40
2,450
600 ~ 2,940
12.0
11.0
1.5 + 1.5 + 1.7
3.2 + 3.2 + 5.0
11.4
2.11
2.11
3.28
7.50
2.80 ~ 8.80
2,250
600 ~ 3,020
11.0
10.1
1.4 + 1.4 + 1.9
3.2 + 3.2 + 6.0
12.4
1.94
1.94
3.62
7.50
2.80 ~ 8.80
2,250
600 ~ 3,020
11.0
10.1
1.3 + 1.3 + 2.1
3.2 + 4.0 + 4.0
11.2
2.14
2.68
2.68
7.50
2.80 ~ 8.70
2,290
600 ~ 3,000
11.2
10.3
1.4 + 1.6 + 1.6
3.2 + 4.0 + 5.0
12.2
1.97
2.46
3.07
7.50
2.80 ~ 9.00
2,170
580 ~ 3,060
10.6
9.7
1.3 + 1.5 + 1.7
3.2 + 4.0 + 6.0
13.2
1.82
2.27
3.41
7.50
2.80 ~ 9.00
2,170
580 ~ 3,060
10.6
9.7
1.2 + 1.5 + 2.0
3.2 + 5.0 + 5.0
13.2
1.82
2.84
2.84
7.50
2.80 ~ 9.00
2,060
520 ~ 2,830
10.1
9.2
1.2 + 1.7 + 1.7
4.0 + 4.0 + 4.0
12.0
2.50
2.50
2.50
7.50
2.80 ~ 9.00
2,170
590 ~ 3,040
10.6
9.7
1.5 + 1.5 + 1.5
4.0 + 4.0 + 5.0
13.0
2.31
2.31
2.88
7.50
2.80 ~ 9.00
2,070
540 ~ 2,830
10.1
9.3
1.5 + 1.5 + 1.7
Width
Depth
mm
296 (511)
296 (511)
296 (542)
296 (695)
296 (750)
inch
11-21/32 (20-1/8)
11-21/32 (20-1/8)
11-21/32 (21-11/32)
11-21/32 (27-3/8)
11-21/32 (29-17/32)
mm
870 (650)
870 (650)
1,070 (780)
1,070 (875)
1,070 (875)
34-9/32 (25-19/32)
42-5/32 (30-23/32)
42-5/32 (34-15/32)
42-5/32 (34-15/32)
inch
34-9/32 (25-19/32)
mm
236 (230)
236 (230)
241 (289)
241 (320)
241 (345)
inch
9-5/16 (9-1/16)
9-5/16 (9-1/16)
9-1/2 (11-13/32)
9-1/2 (12-5/8)
9-1/2 (13-19/32)
Indoor
kg (lb)
9 (20)
9 (20)
12 (26)
12 (26)
12 (26)
Outdoor
kg (lb)
21 (46)
25 (55)
34 (75)
52 (115)
62 (137) ø 6.35
mm
ø 6.35
ø 6.35
ø 6.35
ø 6.35
inch
1/4
1/4
1/4
1/4
1/4
mm
ø 9.52
ø 12.70
ø 12.70
ø 15.88
ø 15.88
inch
3/8
1/2
1/2
5/8
5/8
m
7.5
7.5
7.5
7.5
7.5
Maximum Pipe Length
m
10
15
25
25
30
Maximum Elevation Length
m
5
5
20
20
20
Additional Refrigerant Gas**
g/m
10
10
20
30
30
Indoor
Indoor
Indoor
Indoor
Outdoor
Liquid Side Refrigerant Pipe Diameter Gas Side
Pipe Extension
CS-C24RKH
[CU-C18RKH]
10.81 - 10.61
12.0
Net Weight
CS-C18RKH
[CU-C12RKH]
220 - 240
Height
Dimensions
CS-C12RKH
[CU-C9RKH]
11.30 - 11.03
Moisture Removal
Noise Level
CS-C9RKH
V
Power Input (min-max)
Air Circulation
CS-C28RKH
Voltage
EER
Electrical Data
CS-C18RKH CS-C24RKH
Btu/h
kW
Cooling Capacity
6.0 + 6.0
30
CS-C9RKH
(Random)
2.8 + 2.8 + 2.8
• Specification based on JIS C 9612 standard. • A minimum of 2 indoor units must be connected. • Switchable between 8.5amp or 11amp.
Wireless
Power Supply
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR
CU-C9RKH CU-C12RKH
CU-C18RKH
CU-C24RKH
CU-C28RKH
31
PRODUCT LINE-UP
PRODUCT LINE-UP
WALL-MOUNTED : STANDARD Non-INVERTER Single-Split Type
EASY-TO-USE REMOTE CONTROLLER Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.
Wireless
CS-PC9TKH | CS-PC12TKH
Wireless
CS-PC18TKH | CS-PC24TKH | CS-PC28TKH
SPECIFICATIONS MODEL
EER
2.65-2.70
3.49-3.54
5.28-5.30
6.93-7.03
7.90-8.00
Btu/h
9,040-9,210
11,900-12,100
18,000-18,100
23,600-24,000
26,900-27,300
Btu/hW
10.70 - 10.41
10.17-10.00
9.38-9.14
9.92 - 9.56
9.00-8.98
220 - 240
220 - 240
220 - 240
220 - 240
220 - 240
4.4 - 4.3
5.5 - 5.6
8.9-9.0
11.0 - 10.8
14.0 - 13.1
W
845 - 885
1,170 - 1,210
1,920-1,980
2,380 - 2,510
2,990 - 3,040
1.6
2.1
2.9
4.0
4.7
L/h
3.4
4.4
6.1
8.5
9.9
Indoor
m3/min (ft3/min)
7.9 (279)
9.7 (342)
19.0 (671)
20.8 (734)
22.7 (801)
Outdoor
m3/min (ft3/min)
28.8 (1,020)-29.6 (1,040)
22.0 (780)-23.6 (830)
(Pt/h)
dB (A)
37/26
40/29
43/39
47/42
50/46
Outdoor (H)
dB (A)
47-48
49-50
54-56
56-57
55-57
Width
mm
290 (511)
290 (511)
302 (542)
302 (619)
302 (750)
inch
11-7/16 (20-1/8)
11-7/16 (20-1/8)
11-29/32 (21-11/32)
11-29/32 (24-3/8)
11-29/32 (29-17/32)
mm
799 (650)
799 (650)
1,102 (780)
1,102 (824)
1,102 (875)
31-15/32 (25-19/32)
31-15/32 (25-19/32)
43-13/32 (30-23/32)
43-13/32 (32-15/32)
43-13/32 (34-15/32)
inch mm
197 (230)
197 (230)
244 (289)
244 (299)
244 (345)
inch
7-3/4 (9-1/16)
7-3/4 (9-1/16)
9-5/8 (11-13/32)
9-5/8 (11-25/32)
9-5/8 (13-19/32)
Indoor
kg (lb)
8 (18)
8 (18)
12 (26)
12 (26)
12 (26)
Outdoor
kg (lb)
22 (49)
24 (53)
33 (73)
39 (86)
60 (132) ø 6.35
Refrigerant Pipe Diameter Gas Side
mm
ø 6.35
ø 6.35
ø 6.35
ø 6.35
inch
1/4
1/4
1/4
1/4
1/4
mm
ø 9.52
ø 12.70
ø 12.70
ø 15.88
ø 15.88
inch
3/8
1/2
1/2
5/8
5/8
Chargeless Pipe Length
m
7.5
7.5
7.5
7.5
7.5
Maximum Pipe Length
m
15
15
25
25
30
Maximum Elevation Length
m
5
5
20
20
20
Additional Refrigerant Gas**
g/m
10
10
20
30
30
Indoor
Indoor
Indoor
Indoor
Outdoor
Power Supply
LCD display for an easy overview of the operation status.
2
Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.
3
Quiet function allows you to sleep comfortably at night.
4
Toggles between iAUTO, COOL, and DRY setting mode.
5
Adjusts the fan speed.
6
Delays off timer with temperature control for better sleep.
7
Press up or down to set the temperature.
8
Set the airflow.
9
Set the 24-hour ON & OFF Timer.
COOLING MODELS 1
2
3
4
5
6
Random
CS-PC9TKH CS-PC12TKH
8 7
9
OUTDOOR
Wireless Applicable to STANDARD Non-INVERTER
CU-PC9TKH CU-PC12TKH
CU-PC18TKH
TO SET THE TIMER To turn the unit ON or OFF at a preset time. 1
2
3
CU-PC24TKH
TIMER
ON
1 OFF
*When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
SET
2
33 CANCEL CAN CEL
Select ON or OFF Timer.
Set the time.
Example: OFF at 22:00
CU-PC28TKH
OFF
2
Confirm. TIMER
32
CS-PC18TKH CS-PC24TKH
30.3 (1,070)-31.3 (1,100) 39.0 (1,380)-41.4 (1,460) 55.3 (1,950)-57.3 (2,020)
Indoor (H / L)
Liquid Side
Pipe Extension
[CU-PC28TKH]
V
Depth
Net Weight
CS-PC28TKH
[CU-PC24TKH]
A
Height
Dimensions
CS-PC24TKH
[CU-PC18TKH]
Current
Moisture Removal
Noise Level
CS-PC18TKH
[CU-PC12TKH]
Voltage
Power Input (min-max)
Air Circulation
CS-PC12TKH
[CU-PC9TKH] kW
Cooling Capacity
Electrical Data
CS-PC9TKH
(50Hz)
1
SET
33
CS-PC28TKH
PRODUCT LINE-UP
FEATURES EXPLANATION
Floor-Standing Type
FEATURES EXPLANATION COMFORT RADIANT COOLING
COOLING MODELS
COOLING MODELS
Cools the ceiling and walls first, providing continuous cooling comfort without direct airflow.
SLEEP MODE RADIANT COOLING
iCOMFORT
INVERTER CONTROL
Varies the rotation speed of the compressor for higher energy savings.
Lets you come home to fast cooling. Then enjoy continuous comfort with RADIANT COOLING which avoids direct cooling.
Wireless
Wireless
CS-C18FFH-E CS-C28FFH-E CS-C28FFH8-E
CS-C18FFH-E
QUIET MODE
Detects and reduces waste for more energy savings.
CS-C18FFH-E CS-C28FFH-E CS-C28FFH8-E
Rhythmic temperature-controlled pattern to save energy without sacrificing comfort.
SPECIFICATIONS
(
MODEL
(50Hz)
CS-C18FFH-E CS-C28FFH-E CS-C28FFH8-E CS-C45FFH-E [CU-C18FFH-E]
kW
Cooling Capacity
Btu/h Btu/hW
EER
Electrical Data
Air Circulation
Noise Level
Pt/h Indoor
m³/min(ft³/min)
Outdoor
m³/min(ft³/min)
9.2-9.0
9.5-9.4
9.8
8.7-8.9
9.7
1
1
3
220-240
220-240
380
380-415
230
8.7-8.8
11.9-12.0
4.5
8.4
12.2
1,900-1,950
2,600-2,650
2,500
4,710-4,800
2,550
2.8
4.2
4.2
7.5
4.2
1
5.9
8.9
8.9
15.8
7.39
14.5 (512)-15.5 (547)
15.0 (530)-16.2 (572)
15.0 (530)
27.0 (953)
16.0 (565)
56.0 (1,978)
92 (3,249)
59.5 (2,100)
31.0 (1,094)-32.0 (1,130) 56.0 (1,978)-60.0 (2,120)
Indoor (H/L)
(dB-A)
46/40-47/41
48/42-49/43
48/43
53/47
43/36/33
Outdoor (H)
(dB-A)
(53)-(54)
(53)-(54)
(53)
(57)
51
mm
1,680 (540)
1,680 (795)
1,680 (795)
1,880 (1,175)
1,880 (700)
inch
66-1/8 (21-5/16)
66-1/8 (31-19/64)
66-1/8 (31-19/64)
74 (64-17/64)
74-1/64 (27-9/16)
mm
500 (780)
500 (900)
500 (900)
600 (900)
540 (998)
inch
19-11/16 (30-23/32)
19-11/16 (35-7/16)
19-11/16 (35-7/16)
23-5/8 (35-7/16)
21-16/24 (39/19/64)
mm
298 (289)
298 (320)
298 (320)
350 (320)
357 (320)
inch
Width
11-23/32 (11-3/8)
11-23/32 (12-19/32)
11-23/32 (12-19/32)
13-25/32 (12-19/32)
14-1/16 (12-19/32)
Indoor
kg (lb)
34 (75)
35 (77)
35 (77)
52 (115)
37 (82)
Outdoor
kg (lb)
40 (88)
55 (121)
55 (121)
88 (194)
46 (101)
mm
ø 6.35
ø 9.52
ø 9.52
ø 9.52
ø 6.35
Liquid Side
Pipe Extension
7.20 24,600
W
Refrigerant Pipe Diameter
12.00-12.50 41,000-42,700
V
Depth
Net Weight
7.20 24,600
A
Height
Dimensions
7.20-7.30
Current
Moisture Removal
[CU-E28NFQ]
24,600-25,000
Voltage
L/h
[CU-C45FFH-E]
CS-E28NFQ
5.10-5.15
1
Power Input
[CU-C28FFH8-E]
Gas Side
inch
1/4
3/8
3/8
3/8
1/4
mm
ø 12.70
ø 15.88
ø 15.88
ø 19.05
ø 12.70
inch
1/2
5/8
5/8
3/4
1/2
Chargeless Pipe Length
m
7
7
7
15
7
Maximum Pipe Length
m
10
15
15
30
15
MANUAL HORIZONTAL AIRFLOW DIRECTION CONTROL
AUTOCOMFORT
SOFT DRY OPERATION MODE
AUTOMATIC OPERATION MODE
Starts with cooling to dehumidify, then provides continuous breeze at a low frequency to keep a room dry without much change to the temperature.
Detects high activity levels and adjusts cooling power to improve comfort.
CLEANER AIR nanoe-G
ANTI-DUST COATING
nanoe-G works effectively on airborne particles
Anti-dust coating prevents dust from accumulating on cross flow fan by keeping it clean.
including PM2.5, adhesive and in-filter micro-organisms such as bacteria, viruses and mould ensuring a cleaner living environment.
REMOVABLE, WASHABLE PANEL
DUST SENSOR
Monitors particle concentration levels and turns on nanoe-G if levels are high.
ODOUR-REMOVING FUNCTION
With this function, there's no unpleasant odour when the unit starts up. That's because the fan remains off momentarily, while the source of the odour inside the air conditioner is suppressed. The unit must be in cool or dry mode and the fan speed must be set to automatic.
DUST SENSOR
CONVENIENCE 24-HOUR DUAL ON & OFF REAL SETTING TIMER
AUTO MOVABLE PANEL
Front panel will automatically open and close when ON and OFF.
This feature enables you to preset two different sets of start/stop operation timer (hour and minute) within a 24-hour time frame.
12-HOUR ON & OFF SETTING TIMER LCD WIRELESS REMOTE CONTROL
CHILD LOCK FUNCTION
To protect the safety of children during operation and prevents mishandling.
24-HOUR ON & OFF REAL SETTING TIMER
The exact operating time (hour and minute) of the air conditioner can be set in advance. From here on, the unit will operate in accordance to these preset hours every day until the system is reset.
POWER MONITOR DISPLAY
More lights ON when operating at high power. Less lights ON during low power operations.
WIRELESS REMOTE CONTROL
WIRED REMOTE CONTROL
RELIABILITY RANDOM AUTO RESTART
SELF-DIAGNOSTIC FUNCTION (Random)
LONG PIPING
Should a malfunction occur, the unit diagnoses the problem and shows the corresponding alphanumeric code. This allows for quicker servicing.
TOP-PANEL MAINTENANCE ACCESS
BLUE FIN CONDENSER
OPTIONAL ACCESSORIES
m
7
10
10
20
10
REMOTE CONTROL
PIPE SIZE REDUCER
PIPE SIZE EXPANDER
PIPE SIZE REDUCER
g/m
25
30
30
50
20
Wired Remote Control
Indoor
Indoor
Outdoor
Outdoor
Indoor
Use at the indoor unit’s connection port
Use at the outdoor unit’s connection port
Use at the indoor unit’s connection port
CZ-RD514C
CZ-MA1P
CZ-MA2P
CZ-MA3P
CS-VS10SKH, CS-VS13SKH, CS-VS18SKH, CS-S10TKH, CS-S13TKH, CS-S18TKH, CS-S24TKH, CS-S28TKH CS-PS9TKH, CS-PS12TKH,CS-PS18TKH, CS-PS24TKH CS-S9TKZW, CS-S12TKZW, CS-MS15TKZ, CS-S18TKZW, CS-S24TKZW
CS-S12TKZW, CS-MS15TKZ, CS-S18TKZW
CS-S24TKZW
CS-S24TKZW
Max Elevation Length Additional Refrigerant Gas*
C
): Outdoor Unit
17,400-17,600
ø
Phase
[CU-C28FFH-E]
AIRFLOW DIRECTION CONTROL (UP & DOWN)
POWERFUL MODE
(Random)
TEMPERATURE WAVE
Vertical and horizontal airflow patterns can be combined as desired to achieve optimum comfort, with operation possible by remote even from a distance.
AIRFLOW DIRECTION CONTROL (LEFT & RIGHT)
CS-C28FFH-E CS-C28FFH8-E
ECONAVI CS-C45FFH-E
PERSONAL AIRFLOW CREATION
Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.
Come home to fast cooling. Then enjoy continuous comfort with Shower Cooling which avoids direct cooling.
CS-E28NFQ
CS-C45FFH-E
SLEEP
iAUTO
iAUTO-X
Wireless
Delays off timer with temperature control for better sleep.
Power Supply
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR
CU-C18FFH-E
34
CU-C28FFH-E CU-C28FFH8-E
CU-C45FFH-E
CU-E28NFQ
35
RADIANT COOLING TECHNICAL EXPLANATION
RADIANT COOLING TECHNICAL EXPLANATION
RADIANT COOLING FOR USERS’ COMFORT COOLING
Conventional air conditioner
SKY SERIES
COOLS GENTLY AND EVENLY The SKY Series makes the room evenly cool, even though no airflow feeling. The cooling system of SKY Series gives comfort based on the principle of RADIANT COOLING. 28 27 26 25 24 23 22 21 20 19 18 17
Temperature distribution
Conventional air conditioners are built to blow cold air downwards and directly at people to cool them instantly. However, when in direct contact with cold air for too long, some people experience discomfort and dry skin.
”It's comfortable!" "It's cold!"
˚C
28 27 26 25 24 23 22 21 20 19 18 17
The temperature in all areas of the room can be evenly set at a comfortable level.
”It's comfortable!"
˚C
"I don’t feel much wind!"
"I feel cold wind!"
Air velocity distribution
Comfortable in living space with no wind (less than 0.2 m/s*)
Discharge airflow
Intake airflow
No Air Feeling Area
*Meter per second
No Air Feeling Area
Discharge airflow
Intake airflow
No Air Feeling Area
Test conditions: Measured in stable operation at 25˚C cooling with fan speed set at "HI."
Inspired by the cooling effect of caves, Doctor Naoshi Kakitsuba investigated the benefits of RADIANT COOLING. He found that this gentler and more even cooling method results in a greater feeling of comfort and wellbeing.
RADIANT COOLING REMOVES HEAT FROM CEILING AND WALLS SKY Series makes people comfortable because the radiant heat from ceiling is less.
DR NAOSHI KAKITSUBA DEPT. OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, MEIJO UNIVERSITY JAPAN
Average ceiling temperature: 35˚C
Radiant heat from roof top and ceiling
Mean Radiant Temperature (Measured by Globe Thermometer) 26.2˚C
Average room temperature: 25˚C
Average ceiling temperature: 30˚C
Mean Radiant Temperature (Measured by Globe Thermometer) 26.2˚C
Average room temperature: 25˚C
The globe temperature is about 0.8˚C higher (=About 1.1˚C higher in terms of how people feel comfortable) The globe temperature is a composite temperature used to estimate the effect of temperature, humidity, and solar radiation on humans.
Slightly uncomfortable
PRINCIPLE OF RADIANT COOLING THE PRINCIPLE OFTHE RADIANT COOLING
Conventional Cooling
Heat is absorbed by the breeze on the skin, resulting in a cool feeling.
Sensation evaluation
Slightly comfortable Room Temp.
25 ºC
Comfortable
20%
Slightly comfortable Neither or any side
Conventional air conditioner
100%
Room Temp.
25 ºC Slightly comfortable
Comfortable / Slightly comfortable
Measured in stable operation at 25˚C cooling with fan speed set at "MEDIUM." The actual average room temperature is the same.
The breeze directly contacts the body for cooling.
THE BENEFITS OF RADIANT COOLING RADIANT COOLING
Heat is absorbed by the cool surrounding walls and ceiling, resulting in a cool feeling.
SKYWING angles upwards to cool without direct airflow, thus PREVENTING OVERCOOLING AND MAINTAINS SKIN MOISTURE.
SKY SERIES 60 min.
Skin moisture after 60 minutes
210μS
150μS
71%
60 min.
210μS
206μS
98%
The breeze cools the walls and ceiling, which absorb the body heat. Measured in stable operation at 25˚C cooling with fan speed set at "HI."
*Applicable to ELITE INVERTER only. *All test results are based on internal test.
36
37
nanoe-G TECHNICAL EXPLANATION
nanoe-G TECHNICAL EXPLANATION
THE EFFECTIVENESS OF PM2.5
WHAT IS PM2.5? "Particulate matter," also known as PM is made up of a number of components including extremely small particles and liquid droplets. Sized at less than 2.5 micrometers (PM2.5), these particles are said to pose health problems as they can easily enter our lungs.
Size (μm) Large 10µm
BACTERIA 1µm-10µm
DIAMETER
2.5µm PM2.5 is found in
<2.5μm
<10μm
VIRUS 0.001µm-0.1µm
The effect after 100 minutes in a 40 m³ test space [about the size of a 10 tatami mat room], not the effect in a space where actually used.
1
POLLEN 10µm-100µm
PM2.5
>10μm
In a large space of 40 m³ Removal effect has been evaluated.
PARTICLE SIZE COMPARISON
FINE PARTICLES
BACTERIA / MOULD
DATA ON REMOVAL OF AIRBORNE BACTERIA WAS PRESENTED BY HARVARD SCHOOL OF PUBLIC HEALTH RESEARCHERS AT NANO-SYMPOSIUM AT KYOTO UNIVERSITY, 2012
∙ ∙ ∙ ∙
C/Co (Normalized spore concentration)
POLLEN
AIRBORNE
“Performance evaluation of a novel ionizer for air purification applications”. Dr. S. Rudnick et al. Harvard School of Public Health, Environmental Health Nanoscience Lab.
0.1 nanoe-G on nanoe-G off
nanoe-G
0.01
1 log10 reduction Projection
Experimental data 0.001
0
20
40
60
80
100
120
140
160
A study of the removal effect of airborne bacteria by using an air-conditioner incorporating nanoe-G was carried out in a large space, and the results were presented at Nano-Symposium jointly held in
180
time (min)
Industrial Smoke Exhaust Gas Haze Cigarette Smoke
Small
SOURCES OF PM2.5
AIRBORNE TARGET SUBSTANCE
PM2.5 can be found suspended in the air, including dust, dirt, smoke and liquid droplets. These fine particles come from man-made sources such as the combustion of fossil fuels, open burning and industrial processes as well as natural ones, which include sea sprays and dust carried by strong winds.
PM2.5
Bacteria
SUBSTANCE NAME Cigarette Smoke (as PM2.5)
Staphylococcus aureus (NBRC 12732)
EFFECTIVENESS
PM2.5 Concentration (mg/ m3)
80 min
1.2 1.0
99% removal from the air after 202 minutes of operation.
99%
Kitasato Research Center for Environmental Science
KRCES-Bio. Test Report No. 23_0182
The AC with nanoe-G was operated in a test room (25m³) and aerosol was collected and bacterial count was calculated.
99% removal from the air after 150 minutes of operation.
99%
Kitasato Research Center for Environmental Science
KRCES-Env. Test Report No. 22_0008
The AC with nanoe-G was operated in a test room (25m³) and airborne phages were collected and phage count of the collected air was calculated.
99% removal from the air after 120 minutes of operation.
99%
Kitasato Research Center for Environmental Science
KRCES-Env. Test Report No. 22_0008
nanoe-G was operated in a test chamber (200 Litre) and the phages were collected and phage count of the collected air was calculated.
99% removal from the air after 5 minutes of operation.
nanoe-G was operated in a test chamber (200 Litre) and the influenza viruses were collected and the virus titers were calculated by the Reed and Muench method.
99% removal from the air after 5 minutes of operation.
202 min
90% removal
0.8
99% removal
0.6 0.4
Virus
0.2 0.0 0
30
60
90
120
150
180
210
240
270
300
99%
Kitasato Research Center for Environmental Science
KRCES-Env. Test Report No. 22_0008
99%
Kitasato Research Center for Environmental Science
KRCES-Bio. Test Report No. 23_0140
Time Elapsed (min.)
Influenza (H1N1) 2009 virus
AIRBORNE *1 PM2.5 Removal was certified by FCG Research Institute, Inc
REMOVES
99%
UP TO
*1
PM2.5
• Test Report no. : 25034 PM2.5 : Cigarette Smoke (as PM2.5) Effectiveness is measured on 0.3μm-2.5μm. (Specific size only) This removal effect is not proven for all the airborne toxic substances.
*² Airborne Removal was certified by Kitasato Research Center for Environmental Science
REMOVES
99%
UP TO
*2
BACTERIA VIRUSES and MOULD
• KRCES-Bio. Test Report no. : 23_0182 Bacteria : Staphylococcus aureus (NBRC 12732) • KRCES-Env. Test Report no. : 22_0008 Virus : Escherichia coli phage (øX-174 ATCC 13706-B1) : Influenza (H1N1) 2009 Virus
All results are based on specific testing conditions.
• KRCES-Env. Test Report no. : 23_0140 Mould : Penicillium pinophilum (NBRC 6345)
All tests are not demonstrated under actual usage situation.
All results are based on specific testing conditions.
Mould
Penicillium pinophilum (NBRC 6345)
RESULT
99%
1.6 1.4
METHOD The AC with nanoe-G was operated in a test room (23m³) and the concentration of PM2.5 was measured by PM2.5 Digital Dust Indicator.
Escherichia coli phage (øX-174 ATCC 13706-B1)
Air conditioner with nanoe-G
1.8
TEST REPORT NO
Test Report No. 25034
Legend:
2.0
TESTING INSTITUTE
FCG Research Institute, Inc
PM2.5 REMOVAL EFFICIENCY BASED ON TIME SERIAL MEASUREMENT OF PM2.5 CONCENTRATION
September 2012 by Harvard University and Kyoto University. Test methods: Bacteria removal method: Release of nanoe-G ions. Target: Airborne bacteria, Test results: It is estimated that after three hours of operation the nanoe-G will achieve 2.7 log10 reductions, ~ 1 log10 reduction more, as compared to without nanoe-G.
In view of health hazard associated with spatial distribution of Influenza (H1N1) 2009 virus, nanoe-G removal effectiveness cannot be tested in large test room (25m³). When tested in 200 Litre chamber, nanoe-G was able to decrease Influenza (H1N1) 2009 virus (99%) when it was operated for 5 minutes. Additionally when tested in larger test room (25m³), nanoe-G can remove 99.5% of Coli phage virus when operated for 120 minutes. It was validated that evaluation on the influenza virus could be speculated from the results on the phage according to the test results in a 200 Litre test chamber. It appeared that the air-conditioners in a larger test room (25m³) would be able to remove the influenza virus as effectively as the phage. The AC with nanoe-G was operated in a test room (25m³) and aerosol was collected and fungal spores count was calculated.
99% removal from the air after 90 minutes of operation.
All tests are not demonstrated under actual usage situation.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
38
39
nanoe-G TECHNICAL EXPLANATION
nanoe-G TECHNICAL EXPLANATION
ADHESIVE
HOW DOES IN-FILTER DEACTIVATION WORK?
ODOUR DEODORISATION: THE ODOUR ADHERED ON THE CURTAINS AND SOFA
Test Subject: Test Chamber: Measurement Method:
Adhesive smell of tobacco smoke 20m³ Six-level odour intensity indication method 13-1204
Test report No.:
Odour Intensity
Degree of Smell
0 1
No odour Barely able to detect (detection threshold) Able to recognise a smell, but weak (recognition threshold) Easily perceptible Strong Very Strong
2 3 4 5
4
Odour Intensity
Decrease in odour intensity by one level after 2 hours of operation.
5 4.17 3.25 3
1 Level Down 2.25
2 Natural Decay
AC with
nanoe-G
1 0
Initial
After 2 hours
ADHESIVE TARGET SUBSTANCE
SUBSTANCE NAME
Staphylococcus aureus (NBRC 12732)
Bacteria
Bacteriophage (Phi X 174 NBRC 103405)
Virus
Cladosporium cladosporioides (NBRC 6348)
Mould
Smell of tobacco smoke
Odour
EFFECTIVENESS
99%
99%
Inhibit Mould Growth
Decrease by one level
TESTING INSTITUTE
TEST REPORT NO
METHOD
Test Report No. 11047933001-02
The AC with nanoe-G was operated in a test space (10m³) and viable cells were counted by pour plate method.
99% inactivation after 24 hour operation of nanoe-G. (compared to the original condition/ ventilation mode)
Japan Food Research Laboratories
Test Report No. 11073649001-02
nanoe-G was operated in a test box (90 Litre) and phage infectivity titer was determined by plaque technique.
99% inactivation after 120 minutes operation of nanoe-G. (compared to non-operation)
Japan Food Research Laboratories
OMI ODOR-AIR SERVICE Co.Ltd.
nanoe-G was operated in a test box (1m³) and colonies on the plate were counted.
Test Report No. 11047937001-02
Test Report No. 13-1204
Natural Ion Wind spreads nanoe-G particles that are released from the nanoe-G generator.
Remark: Main power must be switched on for the entire duration.
Remark: The 30-minute fan operation is only applicable when the unit has been operated in COOL /DRY mode.
Remark: Depending on the Air Conditioner’s accumulated operation time, nanoe-G In-Filter Deactivation may be activated only once a day.
Fan Operation : On Flap : Flaps slightly open nanoe-G LED : On
Fan Operation : Off Flap : Closed nanoe-G LED : On
and viruses that are trapped in the filter within 2 hours.
IN-FILTER DEACTIVATION TARGET SUBSTANCE
SUBSTANCE NAME
EFFECTIVENESS
TESTING INSTITUTE
TEST REPORT NO
Bacteria
Staphylococcus aureus (NBRC 12732)
99%
Japan Food Research Laboratories
Test Report No. 12037932001
The growth of the subject was inhibited. (>85% after 7 days)
Decrease in odour intensity by one level after 120 minutes of operation.
nanoe-G deactivates bacteria
The fan operation will run automatically for 30 minutes with the flaps slightly open to ensure the internal components are dry and free from condensation.
Escherichia coli phage (øX-174 ATCC 13706-B1) The AC with nanoe-G was operated in a test room (20m³) and the deodorisation effect on a piece of cloth impregnated with odour components of cigarette smoke was evaluated using six-level odour intensity indication method.
4. DEACTIVATION EFFECT
The air-conditioner first has to be turned off.
RESULT
Japan Food Research Laboratories
3. nanoe-G OPERATION
2. FAN OPERATION
1. POWER “OFF”
Virus
Influenza (H1N1) 2009 Virus
99%
Average 90% on filter (The percentage varies from 78.9% to 96.1% depending on its location)
Japan Food Research Laboratories
Kitasato Research Center for Environmental Science
Test Report No. 12014705001
KRCES-Virus Test Report No. 24_0013
METHOD
RESULT
The test piece impregnated with Staphylococcus aureus was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, viable cells were counted. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left. The test piece impregnated with Escherichia coli phage was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, phage infectivity titer was determined. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left. The test piece impregnated with Influenza (H1N1) 2009 Virus was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, virus infectivity titer was determined. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation. Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
ADHESIVE
ADHESIVE ODOURS *³ Adhesive Deactivation was certified by Japan Food Research Laboratories
DEACTIVATES
99%
UP TO
*3
BACTERIA and VIRUSES
INHIBITS MOULD GROWTH
• Test Report number : 11047933001-02 Bacteria : Staphylococcus aureus (NBRC 12732) • Test Report number : 11073649001-02 Virus : Bacteriophage (Phi X 174 NBRC 103405) • Test Report number : 11047937001-02 Mould : Cladosporium cladosporioides (NBRC 6348) All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
DEODORISES ADHESIVE ODOUR (TOBACCO SMELL)
IN-FILTER DEACTIVATION Adhesive odour deodorisation was certified by OMI ODOR-AIR SERVICE Co. Ltd. • Test Report No. 13-1204 All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
DEACTIVATES
99%
UP TO
*4
BACTERIA and VIRUSES
INHIBITS MOULD GROWTH
*⁴ In-Filter Deactivation was certified by Japan Food Research Laboratories • Test Report number : 12037932001 Bacteria : Staphylococcus aureus (NBRC 12732) • Test Report number : 12014705001 Virus : Escherichia coli phage (φΧ-174 ATCC 13706-B1) All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
40
DEACTIVATES AVERAGE
90%
UP TO
INFLUENZA (H1N1) 2009 VIRUS
In-Filter Deactivation was certified by Kitasato Research Center for Environmental Science • Test Report number : KRCES-Virus Test Report No. 24_0013 Virus : Influenza (H1N1) 2009 Virus All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
41
99% of deactivation after 2-hour
nanoe-G
operation.
99% of deactivation after 2-hour
nanoe-G
operation.
Average 90% deactivation after 2-hour nanoe-G operation. (The percentage varies from 78.9% to 96.1%, depending on its location on filter)
iAUTO-X TECHNICAL EXPLANATION
iAUTO-X TECHNICAL EXPLANATION
TRUE COMFORT IS JUST A TOUCH AWAY
iAUTO-X cools you down 35% faster compared to Panasonic Standard non-Inverter model with high fan.
35
%*
Room Temperature
PREMIUM Inverter: iAUTO-X Mode iAUTO-X Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature: 25˚C with Fan Speed: Auto Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight
Quick
25ºC
Time PREMIUM Inverter with iAUTO-X
Standard non-Inverter: Cooling Mode with High Fan COOL Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature : 25˚C with Fan Speed: High Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight The time to reach the setting temperature was measured. At Panasonic Amenity Room (size: 16.6m²) The effect differs according to conditions in installation and usage.
Standard non-Inverter model with high fan
iAUTO-X will automatically switch fan speed to high fan speed and super high fan speed depending on the temperature difference between the room and the set temperature.
Quick Super High
High Medium Time
At start up, iAUTO will run at super high fan speed to cool the room faster, 15% faster for cooler comfort.
2. MAINTAIN
Sine Wave drive produces smooth wave curves.This reduces power loss or energy waste.
COOLING COMFORT
Conventional rectangle drive produces distortions which results in power efficiency loss.
ADVANTAGES OF SINE WAVE 1. EFFICIENCY UP EVEN AT HIGH ROTATIONAL SPEED PER MINUTE (RPM)
AUTOMATIC FAN SPEED
25ºC
AT START UP
SINE WAVE COMPARISONS
Sine Wave (blue) curves smoothly compared to conventional rectangle (grey)
29ºC
1. FAST COOLING
iAUTO utilises high efficient Sine Wave DC motor to realise both powerful cooling and energy saving.
* Comparison of 1.5HP PREMIUM Inverter with iAUTO-X mode and Standard non-Inverter model with cooling mode
29ºC
Room Temperature
SINE WAVE DRIVE
Faster Cooling
35ºC
iAUTO mode Cool mode with High Fan
35ºC
Fan Speed
FASTER COOLING
MOTOR EFFICIENCY DATA (EX. INDOOR UNIT)
Once the room cools down, iAUTO provides constant cool airflow to maintain a comfortable level of relative humidity, to stay cool and comfortable all day long.
80
CONVENTIONAL COOLING
FAST COOLING
Efficiency (%)
75
Reduced current distortion enables fan motor to start faster, run cooler and perform more efficiently even while running at super high fan speed to help reduce power consumption.
3. AUTOMATIC FAN SPEED
70 65 60 300
500
700
900
1100
1300
1500
Speed (r/min) Sine Wave
Legend:
Conventional rectangle
2. STABLE OPERATION Sine Wave regulates power voltage that is identical to power supplied, ensuring consistent performance and stable operation.
iAUTO automatically switches fan speed to high and super high fan speed depending on the temperature difference between the room and the set temperature.
3. LOW VIBRATION
LOW SPEED
Motor loads run smoother with low vibrations resulting in quieter operation. warmer
cooler
MEDIUM SPEED
QUALITY CONTROL THROUGH SIMULATED LABORATORY TEST Panasonic carried out testing at our own Environmental Testing Room which simulates a standard living room condition. This makes it possible to ensure the air conditioner operates at optimum performance level under varying conditions.
HIGH FAN SPEED SUPER HIGH FAN SPEED
FASTER COOLING
150 SENSORS 16.6m²
Remark: Applicable for PREMIUM Inverter with iAUTO-X
Testing is done in a large space of 16.6m² to simulate the size of an actual living room. Indoor temperature is measured using 150 sensors to get the average room temperature. This ensures the accuracy of indoor temperature data.
*Applicable to PREMIUM INVERTER only.
42
* Comparison of 1.5HP DELUXE Non-INVERTER model with iAUTO Mode and Cooling Mode iAUTO Mode iAUTO Mode, Outside Temperature: 35°C / 24°C Remote setting temperature: 25˚C with Fan Speed: Auto Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight Cooling Mode with High Fan COOL Mode, Outside Temperature: 35˚C/24˚C Remote setting temperature: 25˚C with Fan Speed: High Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight Total power consumption amount is measured for 2 hours under stable operation. At Panasonic Amenity Room (size: 16.6m²) The effect differs according to conditions in installation and usage.
*Applicable to STANDARD INVERTER, STANDARD Non-INVERTER & DELUXE Non-INVERTER.
43
FEATURES COMPARISON
FEATURES COMPARISON
FEATURES COMPARISON ELITE INVERTER
Split Type
PREMIUM INVERTER
STANDARD INVERTER
DELUXE INVERTER Multi-Split
DELUXE Non-INVERTER
STANDARD Non-INVERTER
Floor-Standing
Wall-Mounted
CS-VS10SKH CS-VS13SKH CS-VS18SKH
CS-S10TKH CS-S13TKH
CS-S18TKH CS-S24TKH CS-S28TKH
CS-PS9TKH CS-PS12TKH
CS-PS18TKH CS-PS24TKH
CS-S9TKZW CS-S12TKZW CS-MS15TKZ
CS-S18TKZW CS-S24TKZW
CS-C9RKH CS-C12RKH
CS-C18RKH CS-C24RKH CS-C28RKH
CS-PC9TKH CS-PC12TKH
CS-PC18TKH CS-PC24TKH CS-PC28TKH
CS-C18FFH-E CS-C28FFH-E CS-C28FFH8-E
CS-C45FFH-E
CS-E28NFQ
10m (C18) 15m (C28)
30m
15m
Cooling Models
RADIANT COOLING
COMFORT
COMFORT
CLEANER AIR
CLEANER AIR
CONVENIENCE
CONVENIENCE
Radiant Cooling iComfort iAUTO-X ECONAVI
C
Temperature Wave AUTOCOMFORT
SLEEP
SLEEP Inverter Control iAUTO Quiet Mode Powerful Mode Soft Dry Operation Mode Personal Airflow Creation Airflow Direction Control (Up & Down) Manual Horizontal Airflow Direction Control Manual Airflow Direction Control (Left & Right) Sleep Mode Auto-Control Automatic Operation Mode (Cooling)
nanoe-G
Anti-Dust Coating Odour-Removing Function
Removable, Washable Panel
DUST SENSOR
Dust Sensor
24-Hour Dual ON & OFF Real Setting Timer 24-Hour ON & OFF Real Setting Timer 12-Hour ON & OFF Setting Timer LCD Wireless Remote Control Wireless Remote Control Wired Remote Control
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
(Optional)
Auto Movable Panel Child Lock Function Power Monitor Display
RELIABILITY
RELIABILITY
Auto Restart
(Random)
Random Auto Restart (32 Restart Patterns) Blue Fin Condenser Long Piping (Numbers indicate the maximum pipe length)
15m (VS10/13) 30m (VS18)
15m
20m (S24) 30m (S18/28)
15m
15m (PS18) 20m (PS24)
**Refer Page 28
**Refer Page 28
10m (C9) 15m (C12)
25m (C18/C24) 30m (C28)
15m
25m (PC18/PC24) 30m (PC28)
Top-Panel Maintenance Access Self-Diagnostic Function
44
45
MODEL LINE-UP
MODEL LINE-UP
9,000
Capacity (Btu/h)
10,000
12,000
13,000
15,000
18,000
24,000
28,000
45,000
ELITE INVERTER
FEATURES
Wall-Mounted
ELITE INVERTER CS-VS10SKH
Page 22-23
CS-VS13SKH
(CU-VS10SKH)
CS-VS18SKH
(CU-VS13SKH)
(CU-VS18SKH)
(CS-VS10SKH)
PREMIUM INVERTER
PREMIUM INVERTER WIDE
FEATURES
Wall-Mounted
PREMIUM INVERTER Page 24-25
CS-S10TKH
CS-S13TKH
(CU-S10TKH)
CS-S18TKH
(CU-S13TKH)
(CU-S18TKH)
STANDARD INVERTER
CS-S24TKH (CU-S24TKH)
CS-S28TKH (CU-S28TKH)
STANDARD INVERTER WIDE
FEATURES
Wall-Mounted
STANDARD INVERTER Page 26-27
CS-PS9TKH
CS-PS18TKH
CS-PS12TKH
(CU-PS9TKH)
(CU-PS18TKH)
(CU-PS12TKH)
DELUXE INVERTER
CS-PS24TKH (CU-PS24TKH)
DELUXE INVERTER WIDE
FEATURES
Wall-Mounted
DELUXE INVERTER MULTI-SPLIT
CS-S9TKZW
Page 28-30
CS-S12TKZW
(CU-2S18PKZ) (CU-3S27KKZ)
(CU-2S18PKZ) (CU-3S27KKZ)
CS-MS15TKZ (CU-3S27KKZ)
CS-S18TKZW (CU-3S27KKZ)
DELUXE
CS-S24TKZW (CU-3S27KKZ)
DELUXE WIDE
FEATURES
Wall-Mounted
DELUXE NON-INVERTER Page 31
CS-C9RKH
CS-C12RKH (CU-C12RKH)
(CU-C9RKH)
CS-C18RKH (CU-C18RKH)
STANDARD
CS-C24RKH (CU-C24RKH)
CS-C28RKH (CU-C28RKH)
STANDARD WIDE
FEATURES
Wall-Mounted
STANDARD NON-INVERTER Page 32-33
CS-PC9TKH (CU-PC9TKH)
CS-PC12TKH (CU-PC12TKH)
CS-PC18TKH (CU-PC18TKH)
FLOOR STANDING
CS-PC24TKH (CU-PC24TKH)
FEATURES
CS-C28FFH-E (CU-C28FFH-E)
(CU-C18FFH-E)
Page 34
(CU-PC28TKH)
FLOOR STANDING
CS-C18FFH-E
FLOOR-STANDING
CS-PC28TKH
CS-C45FFH-E (CU-C45FFH-E)
CS-C28FFH8-E (CU-C28FFH8-E)
FLOOR STANDING
FLOOR STANDING
FEATURES
CS-E28NFQ
FLOOR-STANDING
(CU-E28NFQ)
Page 34
( ): Outdoor Unit
46
Cooling Models
47