Panasonic SKY SERIES Air Conditioner 2016

Page 1

AIR CONDITIONER 2016/2017

A I R CO N D I T I O N E R

Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. The contents of this catalogue are accurate as of January 2016. Due to printing considerations, the actual colours may vary slightly from those shown. All graphics are provided merely for the purpose of illustrating a point.

Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.

AC-ASIA-C-16


02 - 03

THE FUTURE IS UP 1958 marked the start of Panasonic’s venture into creating air conditioners through cutting edge technology. Today, we bring you a quantum leap in design and performance, creating a new standard for how all air conditioners will be made. Peerless design. Powerful cooling. Perfect comfort.

CONTENT

02 - 03

10 - 11

18 - 21

30 - 35

The Future Is Up

RADIANT COOLING

04 - 05

12 - 13

22 - 23

36 - 37

The Benefits of RADIANT COOLING

Technical Explanation

Technical Explanation

14 - 15

24 - 27

38 - 45

Kai Ken Bi

06 - 07 SKY STREAM DESIGN

08 - 09

SKYWING

Technical Explanation

& DUST SENSOR

16 - 17

Backlit SKY Controller

28 - 29

+

Model Line Up ELITE Inverter Single-Split PREMIUM Inverter Single-Split Deluxe non-Inverter Single-Split Standard non-Inverter Single-Split

46 - 47

Features Comparison and Explanation

48 - 49

Model Line Up

THE FUTURE IS UP


04 - 05

COMFORT Essential air conditioner functions that cool you the way you want.

KAI

HEALTH Clean and fresh air that improves your health and wellbeing.

KEN

THE PHILOSOPHY OF PANASONIC AIR CONDITIONER COMPANY At Panasonic Air Conditioner Company, we’re constantly finding new ways to improve your life. Our innovations bring you comfort when you need it most, take care of your health and beautify your homes and lives.

BEAUTY Minimalist and modern air conditioners that beautify your homes.

BI

KAI KEN BI


06 - 07

SKY STREAM DESIGN - FORM & FUNCTION UP The SKY STREAM design embodies the elegance and pursuit of perfection inherent in Japanese design philosophy. Each timeless, precise line and feature creates an unmistakable impression of premium luxury. Yet the true power of its design is only revealed when it is switched on.

MODERN & MINIMALIST LINES Sleek and striking design that makes it a luxurious complement to designer interior.

MULTIDIRECTIONAL ARM Experience better agility through better control with a multidirectional arm that adjusts cooling the way you want it.

SLIDING LED PANEL When switched on, the Sliding LED Panel slides open to reveal its setting indicators.

SKY STREAM DESIGN


08 - 09

SKYWING

SKYWING - FLEXIBILITY UP The new SKYWING is set to create a new standard in air conditioner design. Located at the top, the SKYWING is better able to direct cool air towards the ceiling. This cool air naturally glides along the surface, spreading throughout the room and down the walls. Heat is removed from the ceiling and walls, resulting in a feeling of even, all-round coolness – RADIANT COOLING.

MULTIDIRECTIONAL ARM

Controlled by a Multidirectional Arm, the SKYWING can cool you two ways: RADIANT COOLING

FAST COOLING

VERSATILE COOLING COMFORT WITH SKYWING

The SKYWING angles upwards to direct cool air towards the ceiling and walls, spreading cool air gently and evenly throughout the room.

The SKYWING angles downward to provide you fast cooling at start up. Together with the high-powered Inverter compressor technology, P-TECh, SKY Series gives you extreme cool air with extra fast speed.

At the touch of a button, the SKYWING tilts down for you to enjoy Panasonic’s powerful and efficient Fast Cooling whenever you need to cool down quickly. Experience more powerful cooling from the moment you switch on the air conditioner. Once the room has reached the set temperature, the SKYWING will adjust to RADIANT COOLING for continuous comfort.

* Applicable to ELITE Inverter only.


10 - 11

RADIANT COOLING

RADIANT COOLING

2 1

- ALL-ROUND COOLING UP Ceilings and walls tend to trap heat, which make living spaces inside hot and uncomfortable. The solution was inspired by a scientific principle called the Coanda Effect.

4 3

THE PRINCIPLE OF THE COANDA EFFECT

The Coanda Effect is the tendency of airflow to be drawn to a surface and to flow along it.

RADIANT COOLING AIRFLOW ASSESSMENT AIRFLOW SMOKE TEST

Here is how RADIANT COOLING works:

TEMPERATURE DISTRIBUTION TEST

BOTTOM AIR INTAKE

4 The room is evenly cooled down.

Instead of blowing cold air directly onto people, the SKYWING directs the airflow upwards to cool the ceiling and walls.

CONVENTIONAL AIR CONDITIONER

RADIANT COOLING

Cold air blows downward, leaving some parts of the room warmer and others colder.

By cooling the ceiling and walls first, comfortable cooling spreads evenly across the room.

Hot air is drawn in from the bottom, and cool air discharged from the top to facilitate the even distribution of cool air.

3 Heat trapped in the ceiling and walls is removed.

2 Cool air is evenly distributed throughout the room.

1 Cool air is directed towards the ceiling.

RADIANT COOLING cools without direct airflow. The feeling is just like walking into a mall.

* Applicable to ELITE Inverter only.


12 - 13

THE BENEFITS OF RADIANT COOLING

Conventional air conditioner

RADIANT COOLING FOR USERS’ COMFORT COOLING - BENEFITS UP

COOLS GENTLY AND EVENLY The SKY Series makes the room evenly cool, even though no airflow feeling. The cooling system of SKY Series gives comfort based on the principleof RADIANT COOLING. 28 27 26 25 24 23 22 21 20 19 18 17

Temperature distribution

28 27 26 25 24 23 22 21 20 19 18 17

”It's comfortable!" "It's cold!"

˚C

”It's comfortable!"

"I don’t feel much wind!"

"I feel cold wind!"

Air velocity distribution

Comfortable in living space with no wind (less than 0.2 m/s*)

Discharge airflow

Intake airflow

*Meter per second

No Air Feeling Area

Discharge airflow

Intake airflow

No Air Feeling Area

Inspired by the cooling effect of caves, Doctor Naoshi Kakitsuba investigated the benefits of RADIANT COOLING. He found that this gentler and more even cooling method results in a greater feeling of comfort and wellbeing.

The temperature in all areas of the room can be evenly set at a comfortable level.

˚C

No Air Feeling Area

Conventional air conditioners are built to blow cold air downwards and directly at people to cool them instantly. However, when in direct contact with cold air for too long, some people experience discomfort and dry skin.

DR NAOSHI KAKITSUBA

SKY SERIES

Test conditions: Measured in stable operation at 25˚C cooling with fan speed set at "HI."

RADIANT COOLING REMOVES HEAT FROM CEILING AND WALLS SKY Series makes people comfortable because the radiant heat from ceiling is less.

Average ceiling temperature: 35˚C

Radiant heat from roof top and ceiling

Mean Radiant Temperature (Measure by Globe Thermometer) 26.2˚C

Average room temperature: 25˚C

DEPT. OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, MEIJO UNIVERSITY JAPAN

Average ceiling temperature: 30˚C

Mean Radiant Temperature (Measure by Globe Thermometer) 26.2˚C

Average room temperature: 25˚C

The globe temperature is about 0.8˚C higher (=About 1.1˚C higher in terms of how people feel comfortable) The globe temperature is a composite temperature used to estimate the effect of temperature, humidity, and solar radiation on humans.

Slightly uncomfortable

PRINCIPLE OF RADIANT COOLING THE PRINCIPLE OFTHE RADIANT COOLING

Conventional Cooling

Sensation evaluation

Slightly comfortable Room Temp.

25 ºC

Heat is absorbed by the breeze on the skin, resulting in a cool feeling.

Comfortable

20%

Slightly comfortable Neither or any side

100%

Room Temp.

25 ºC

Comfortable / Slightly comfortable

Slightly comfortable

Conventional air conditioner

Measured in stable operation at 25˚C cooling with fan speed set at "MEDIUM." The actual average room temperature is the same.

The breeze directly contacts the body for cooling.

MAINTAIN SKIN MOISTURE AND PREVENTS DRY SKIN RADIANT COOLING

Heat is absorbed by the cool surrounding walls and ceiling, resulting in a cool feeling.

Skin doesn’t become dry even in a room with SKY Series operating.

SKY SERIES Skin moisture after 60 minutes

60 min.

210μS

150μS

71%

60 min.

210μS

206μS

98%

The breeze cools the walls and ceiling, which absorb the body heat. Measured in stable operation at 25˚C cooling with fan speed set at "HI."

* Applicable to ELITE Inverter only. *All test results are based on internal test.


14 - 15

featuring

nanoe-G

& DUST SENSOR

REMOVES DOWN TO PM2.5

DUST SENSOR

nanoe-G releases negative ions which attach

- HEALTH & WELLBEING UP

to particles as small as PM2.5, the measuring benchmark of air quality monitoring agencies. These particles are then brought back to the positively-charged filter and removed from the air.

SKY Series also features Panasonic’s advanced air purification system, nanoe-G, which now comes with an innovative new DUST SENSOR.

Please refer to page 30 - 31

AUTOMATED ACTIVATION The DUST SENSOR automatically switches on nanoe-G to purify the air whenever a high level of particle concentration is detected.

CONSTANT AIR MONITORING The DUST SENSOR is constantly monitoring particle concentration levels in the room.

LED

ACTIVITY

DUST SENSOR

WHITE

AIR IS CLEAN

nanoe-G

OFF

When particle concentration level is safe, the indicator on the LED panel is white.

LED

ACTIVITY

DUST SENSOR

RED

AIR IS DIRTY

nanoe-G

WHITE

nanoe-G IS ACTIVATED TO PURIFY THE AIR

When particle concentration level is high, the indicator light turns red. nanoe-G switches on to purify the air.

* Applicable to ELITE Inverter only.


16 - 17

BACKLIT SKY CONTROLLER

SKY CONTROLLER - VERSATILE CONTROL UP The remote control has been redesigned for maximum ease of use and to complement the stylish new design for SKY Series. With simple and intuitive controls, the Sky Controller comes with various settings that meet your everyday air conditioning needs.

BACKLIT LED SCREEN The Sky Controller reveals its settings in a better light thanks to the new backlit screen. Now you can adjust your settings without having to switch on the lights.

DISTINCTIVE SLIDING COVER A smooth sliding cover does not only enhance the remote’s clean lines, but keeps the buttons free from dirt and smudges.

PRECISE TEMPERATURE CONTROL With the Sky Controller’s 0.5°C temperature control, enjoy more precise temperature regulation and experience greater comfort.

* Applicable to ELITE Inverter only.


18 - 19

i A U TO - X

- POWER & SPEED UP iAUTO-X provides powerful instant cooling. Joining forces with fast, high-powered inverter control through the use of Panasonic Thermal Enhancement Technology (P-TECh), twin flaps direct the airflow for fast cooling. Delivering this powerful cooling airflow makes possible a 35% reduction in the time required to reach the set temperature.

P-TECh The new Panasonic Thermal Enhancement Technology (P-TECh) enables the compressor to achieve maximum frequency in the shortest time from start up. This lets you enjoy more powerful cooling from the moment you switch on the air conditioner.

P-TECh

HIGHEST FREQUENCY

2015 Panasonic

EQUEN MAX FR DASH T O

Compressor Frequency (Hz)

CY

DASH & HIGH COMPRESSOR FREQUENCY

2014 Panasonic

Time (min.)

* P-TECh is applicable for ELITE Inverter and PREMIUM Inverter only.


20 - 21

i A U TO - X

FA S T C O O L I N G - HAPPINESS IS COMING HOME TO FAST COOLING On a hot day, feel the satisfaction of quick cooling that happens in an instant.

FASTER COOLING

On a hot day, feel the satisfaction of quick cooling that happens in an instant.

iAUTO-X cools you down 35% faster compared to Panasonic Standard non-Inverter model with high fan. Room Temperature 35ºC

AUTOMATIC FAN SPEED iAUTO-X will automatically switch fan speed to high fan speed and super high fan speed depending on the temperature difference between the room and the set temperature.

29ºC

Quick

PREMIUM Inverter with iAUTO-X Standard non-Inverter model with high fan

25ºC

Time

LOW SPEED

MEDIUM SPEED

PREMIUM INVERTER WITH iAUTO-X

STANDARD NON-INVERTER MODEL WITH HIGH FAN

35

HIGH FAN SPEED

%*

SUPER HIGH FAN SPEED

Faster Cooling

* Comparison of 1.5HP PREMIUM Inverter with iAUTO-X mode and Standard non-Inverter model with cooling mode PREMIUM Inverter: iAUTO-X Mode iAUTO-X Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature: 25˚C with Fan Speed: Auto Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight Standard non-Inverter: Cooling Mode with High Fan COOL Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature : 25˚C with Fan Speed High Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight The time to reach the setting temperature was measured. At Panasonic Amenity Room (size: 16.6m²) The effect differs according to conditions in installation and usage.

Remark: Applicable for PREMIUM Inverter with iAUTO-X

warmer

cooler * Applicable to PREMIUM Inverter only.


22 - 23

SHOWER COOLING - COMFORT THAT GOES ON AND ON WITH SHOWER COOLING After reaching the set temperature, Shower Cooling directs airflow towards the ceiling to avoid direct cooling. This helps distribute cool air evenly throughout the room, giving you longer lasting comfort.

i A U TO - X T E C H N I C A L E X P L A N AT I O N

AEROWINGS features twin flaps that give you more control over the direction of the airflow. * Applicable to PREMIUM Inverter, Standard Inverter, Standard non-Inverter & Semi Deluxe non-Inverter.

INNER FLAP

OUTER FLAP

Panasonic Air Conditioners with Aerowings feature an indoor design with wider intake grille and super-high fan speed to produce bigger air volume.

PKT (2014)

RKH (2016)

HOT AIR INTAKE 214mm

MORE HOT AIR INTAKE BIG INTAKE

BIGGER INTAKE

236mm

FAN SPEED HIGH SUPER HIGH*

Panasonic Air Conditioners feature an intake grille which is 22 mm wider and improved indoor fan speed that goes up to a super-high fan speed at start up. The chassis design generates bigger air volume that contributes to faster cooling.

FOR SHOWER COOLING Before you feel too cold and uncomfortable, AEROWINGS shifts the airflow upwards to spread cool air over a wider area. This ensures cool air is evenly distributed throughout the room and you can stay comfortable without experiencing continuous direct cooling.

HONEYCOMB INTAKE GRILLE The Honeycomb Intake Grille has a wider opening to increase the suction of hot air from the room so that the room can be cooled faster. The stronger honeycomb structure also offers the air conditioner better protection. HOT AIR INTAKE

* Applicable to PREMIUM Inverter only.


24 - 25

- ENERGY SAVING

E C O N AV I + I N V E R T E R

COOL. ECO. TOGETHER. With ECONAVI’s Human Activity Sensors and Panasonic INVERTER’s alternating speed frequency, enjoy energy saving highs while experiencing ultimate comfort.

THE PERFECT MATCH FOR HOME LIVING ECONAVI and INVERTER is a perfect match of energy saving features that keeps air conditioning in your home more efficient and comfortable throughout the day.

SAVES YOU MORE ENERGY FOR PEACE OF MIND Your Panasonic Air Conditioner simply knows when to keep power usage at a minimum. So, you can rest and relax comfortably at home knowing that you can save energy.

* Comparison of 1.5HP Inverter model with ECONAVI (with Dual Human Activity Sensor, Sunlight Sensor, and Temperature Wave) ON and 1.5HP Standard non-Inverter (Cooling) Inverter with ECONAVI: ECONAVI ON, Outside Temperature: 35˚C/24˚C Remote setting temperature: 25˚C with Fan Speed High Horizontal Airflow direction: Step 3, Vertical Airflow direction: ECONAVI mode Setting temperature goes up 2˚C in total, 1˚C controlled by ECONAVI activity level detection and another 1˚C controlled by ECONAVI light intensity detection. Temperature Wave is ON Standard non-Inverter without ECONAVI: Outside Temperature: 35˚C/24˚C Remote setting temperature: 25˚C with Fan Speed High Horizontal Airflow direction: Step 3, Vertical Airflow direction: Straight Total power consumption amount is measured for 2 hours under stable operation. At Panasonic Amenity Room (size: 16.6m²) This is the maximum energy saving value, and the effect differs according to conditions in installation and usage.

* Applicable to PREMIUM Inverter only.


26 - 27

ECONAVI SENSORS

E C O N AV I + I N V E R T E R

INVERTER

ECONAVI has two sensors; the Human Activity Sensor and the Sunlight Sensor. Together, they monitor human location, movement, absence, and sunlight intensity to use energy more efficiently.

NON-INVERTER Room Big temperature temperature fluctuations

HUMAN ACTIVITY SENSOR

SUNLIGHT SENSOR

Output power

Set temperature

ON

OFF

ON

OFF

ON

A conventional non-INVERTER air conditioner can only operate at a constant speed which is too powerful to maintain the set temperature. Thus, it switches the compressor on and off repeatedly. This results in wider temperature fluctuations leading to wasteful consumption of energy.

Time

Legend:

SUNLIGHT DETECTION

Output Power

Temperature

Remark: Energy is wasted by switching the compressor ON and OFF to maintain the set temperature.

INVERTER

Output power

Room Little temperature temperature fluctuations

Set temperature

ON Time

HUMAN ACTIVITY DETECTION Legend:

ECONAVI SAVES YOU ENERGY BECAUSE IT SENSES:

Output Power

Temperature

The Panasonic INVERTER air conditioner varies the rotation speed of the compressor, providing a precise method of maintaining the set temperature. Thus, Panasonic INVERTER air conditioners give you exceptional energy saving performance while ensuring you stay comfortable at all times.

Remark: Saves energy by varying the rotation speed of the compressor to maintain the set temperature.

CONSTANT COMFORT

Whether it’s a sunny day or at night.

Where you are.

Precise temperature control with a wide power output range enables an INVERTER air conditioner to meet different room occupancy levels – thus ensuring constant comfort. MAXIMUM POWER

MEDIUM POWER

MINIMUM POWER

Compressor rotation speed: HIGH

Normal condition

Compressor rotation speed: SLOW

SUNLIGHT DETECTION

AREA SEARCH

When you leave the room. TEMPERATURE WAVE

ABSENCE DETECTION

When you are less active.

Adapts rhythmic temperature control after detecting low activity level. When required, the unit operates at full power.

Power: 4.20kW

When not required, the unit operates at low power to save energy.

Power: 3.67kW

Power: 0.92kW

ACTIVITY DETECTION Graph shows the 1.5HP PREMIUM Inverter model’s wide power output range during cooling.

* Applicable to PREMIUM Inverter only.


28 - 29

PURIFIES AIR IN YOUR HOME DOWN TO THE SMALLEST DETAIL

- AIR PURIFICATION

nanoe-G releases 3 trillion of fine particles to clean the air in your home environment for fresher and cleaner living.

1

REMOVAL OF AIRBORNE PARTICLES

nanoe-G can effectively remove up to 99% of PM2.5*1 and airborne particles*2 such as bacteria, viruses and mould. *1

1 *š *²

PM2.5, Bacteria, Viruses & Mould Removal

AIRBORNE

2 Remark: * 3 trillion is the simulated number of nanoe-G fine particles under the mentioned conditions. Actual measured nanoe-G fine particles at the centre 2 of the room (13m ):100k/cc calculated number of nanoe-G fine particles in the entire room assuming they are evenly distributed.

Removal of airborne particles, even those smaller than 2.5 micrometers in size (PM2.5). Airborne particles:

PM2.5

Bacteria

Viruses

DEACTIVATION OF ADHESIVE MICRO-ORGANISMS AND DEODORISATION OF ADHESIVE ODOURS

nanoe-G particles are able to deactivate up to 99%*3 of bacteria, viruses and inhibit mould growth that settles on surfaces around you. The odours adhered on the curtains and sofa are deodorised.

Mould

*3

Natural Ion Wind spreads nanoe-G fine particles that are released from the nanoe-G generator.

IN-FILTER DEACTIVATION

3 *4

nanoe-G catches airborne particles

Bacteria & Viruses Deactivation

Deactivates bacteria and viruses trapped in the filter.

2 Mechanism

*3

Odour Particle

Bacteria & Viruses Deactivation

nanoe-G Strike Odour Particles

&*2 Please refer to page 30 - 32

Decompose and Remove Odour

ADHESIVE Deactivates adhesive micro-organisms and deodorises adhesive odours.

3 trillion* nanoe-G fine particles released from the generator.

3

Please refer to page 33

IN-FILTER DEACTIVATION With In-Filter Deactivation, nanoe-G deactivates 99%*4 of bacteria and viruses trapped inside the filter. *4

Please refer to page 34 & 35

nanoe-G


30 - 31

i A U TO - X

nano e-G

T E C H N I C A L E X P L A N AT I O N

SOURCES OF PM2.5

W H AT I S PM2.5?

PM2.5 can be found suspended in the air, including dust, dirt, smoke and liquid droplets. These fine particles come from man-made sources such as the combustion of fossil fuels, open burning and industrial processes as well as natural ones, which include sea sprays and dust carried by strong winds.

"Particulate matter," also known as PM is made up of a number of components including extremely small particles and liquid droplets. Sized at less than 2.5 micrometers (PM2.5), these particles are said to pose health problems as they can easily enter our lungs. PM2.5 REMOVAL EFFICIENCY BASED ON TIME SERIAL MEASUREMENT OF PM2.5 CONCENTRATION

POLLEN

BACTERIA / MOULD

FINE PARTICLES

PM2.5

DIAMETER >10μm

<2.5μm

<10μm

PM2.5 Concentration (mg/ m3)

22 | 23

Legend:

2.0

Air conditioner with nanoe-G

1.8 1.6 1.4

80 min

1.2 1.0

202 min

90% removal

0.8

99% removal

0.6 0.4 0.2 0.0 0

30

60

90

120

150

180

210

240

270

300 Time Elapsed (min.)

PARTICLE SIZE COMPARISON AIRBORNE PARTICLE SIZE COMPARISON

REMOVES

Size (μm) Large

POLLEN 10µm-100µm

10µm

99

%*1 PM2.5

REMOVES

*2 % 99

BACTERIA VIRUSES and MOULD

BACTERIA 1µm-10µm 2.5µm PM2.5 is found in

VIRUS 0.001µm-0.1µm

∙ ∙ ∙ ∙

Industrial Smoke Exhaust Gas Haze Cigarette Smoke

Small

*1 PM2.5 Removal was certified by FCG Research Institute, Inc

*² Airborne Removal was certified by Kitasato Research Center for Environmental Science

• Test Report no. : 25034 PM2.5 : Cigarette Smoke (as PM2.5)

• KRCES-Bio. Test Report no. : 23_0182 Bacteria : Staphylococcus aureus (NBRC 12732)

Effectiveness is measured on 0.3μm-2.5μm. (Specific size only) This removal effect is not proven for all the airborne toxic substances.

• KRCES-Env. Test Report no. : 22_0008 Virus : Escherichia coli phage (øX-174 ATCC 13706-B1) : Influenza (H1N1) 2009 Virus

All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

• KRCES-Env. Test Report no. : 23_0140 Mould : Penicillium pinophilum (NBRC 6345) All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.


22 | 23

32 - 33

i A U TO - X

THE EFFECTIVENESS OF PM2.5

nano e-G

T E C H N I C A L E X P L A N AT I O N

ADHESIVE ODOUR DEODORISATION: THE ODOUR ADHERED ON THE CURTAINS AND SOFA

AIRBORNE DATA ON REMOVAL OF AIRBORNE BACTERIA WAS PRESENTED BY HARVARD SCHOOL OF PUBLIC HEALTH RESEARCHERS AT NANO-SYMPOSIUM AT KYOTO UNIVERSITY, 2012

nanoe-G

0.1 nanoe-G on nanoe-G off 0.01

1 log10 reduction Projection

Experimental data 0

20

40

60

80

100

120

140

160

180

time (min)

A study of the removal effect of airborne bacteria by using an air-conditioner incorporating nanoe-G was carried out in a large space, and the results were presented at Nano-Symposium jointly held in September 2012 by Harvard University and Kyoto University. Test methods: Bacteria removal method: Release of nanoe-G ions. Target: Airborne bacteria, Test results: It is estimated that after three hours of operation the nanoe-G will achieve 2.7 log10 reductions, ~ 1 log10 reduction more, as compared to without nanoe-G.

Adhesive smell of tobacco smoke 20m³ Six-level odour intensity indication method 13-1204

Odour Intensity

Degree of Smell

0 1 2 3 4 5

No odour Barely able to detect (detection threshold) Able to recognise a smell, but weak (recognition threshold) Easily perceptible Strong Very Strong

Odour Intensity

Test Subject: Test Chamber: Measurement Method: Test report No.:

“Performance evaluation of a novel ionizer for air purification applications”. Dr. S. Rudnick et al. Harvard School of Public Health, Environmental Health Nanoscience Lab.

1

C/Co (Normalized spore concentration)

4

The effect after 100 minutes in a 40 m³ test space [about the size of a 10 tatami mat room], not the effect in a space where actually used.

In a large space of 40 m³ Removal effect has been evaluated.

0.001

5

Decrease in odour intensity by one level after 2 hours of operation.

4.17 3.25

3

1 Level Down 2.25

2 Natural Decay

AC with

nanoe-G

1 0

Initial

After 2 hours

ADHESIVE AIRBORNE TARGET SUBSTANCE

SUBSTANCE NAME

PM2.5

Cigarette Smoke (as PM2.5)

Bacteria

Staphylococcus aureus (NBRC 12732)

EFFECTIVENESS

TESTING INSTITUTE

TEST REPORT NO

Test Report No. 25034

The AC with nanoe-G was operated in a test room (23m³) and the concentration of PM2.5 was measured by PM2.5 Digital Dust Indicator.

99% removal from the air after 202 minutes of operation.

99%

Kitasato Research Center for Environmental Science

KRCES-Bio. Test Report No. 23_0182

The AC with nanoe-G was operated in a test room (25m³) and aerosol was collected and bacterial count was calculated.

99% removal from the air after 150 minutes of operation.

99%

Kitasato Research Center for Environmental Science

KRCES-Env. Test Report No. 22_0008

The AC with nanoe-G was operated in a test room (25m³) and airborne phages were collected and phage count of the collected air was calculated.

99% removal from the air after 120 minutes of operation.

99%

Kitasato Research Center for Environmental Science

KRCES-Env. Test Report No. 22_0008

nanoe-G was operated in a test chamber (200 Litre) and the phages were collected and phage count of the collected air was calculated.

99% removal from the air after 5 minutes of operation.

nanoe-G was operated in a test chamber (200 Litre) and the influenza viruses were collected and the virus titers were calculated by the Reed and Muench method.

99% removal from the air after 5 minutes of operation.

99%

Virus

Mould

Penicillium pinophilum (NBRC 6345)

RESULT

FCG Research Institute, Inc

Escherichia coli phage (øX-174 ATCC 13706-B1)

Influenza (H1N1) 2009 virus

METHOD

99%

99%

Kitasato Research Center for Environmental Science

Kitasato Research Center for Environmental Science

KRCES-Env. Test Report No. 22_0008

KRCES-Bio. Test Report No. 23_0140

Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

SUBSTANCE NAME

Bacteria

Staphylococcus aureus (NBRC 12732)

Virus

Mould

TESTING INSTITUTE

TEST REPORT NO

99%

Japan Food Research Laboratories

Bacteriophage (Phi X 174 NBRC 103405)

99%

Cladosporium cladosporioides (NBRC 6348)

Inhibit Mould Growth

Smell of tabacco smoke

Odour

EFFECTIVENESS

Decrease by one level

99% removal from the air after 90 minutes of operation.

METHOD

RESULT

Test Report No. 11047933001-02

The AC with nanoe-G was operated in a test space (10m³) and viable cells were counted by pour plate method.

99% inactivation after 24 hour operation of nanoe-G. (compared to the original condition/ ventilation mode)

Japan Food Research Laboratories

Test Report No. 11073649001-02

nanoe-G was operated in a test box (90 Litre) and phage infectivity titer was determined by plaque technique.

99% inactivation after 120 minutes operation of nanoe-G. (compared to non-operation)

Japan Food Research Laboratories

Test Report No. 11047937001-02

nanoe-G was operated in a test box (1m³) and colonies on the plate were counted.

The growth of the subject was inhibited. (>85% after 7 days)

Test Report No. 13-1204

The AC with nanoe-G was operated in a test room (20m³) and the deodorisation effect on a piece of cloth impregnated with odour components of cigarette smoke was evaluated using six-level odour intensity indication method.

Decrease in odour intensity by one level after 120 minutes of operation.

OMI ODOR-AIR SERVICE Co.Ltd.

Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

ADHESIVE

In view of health hazard associated with spatial distribution of Influenza (H1N1) 2009 virus, nanoe-G removal effectiveness cannot be tested in large test room (25m³). When tested in 200 Litre chamber, nanoe-G was able to decrease Influenza (H1N1) 2009 virus (99%) when it was operated for 5 minutes. Additionally when tested in larger test room (25m³), nanoe-G can remove 99.5% of Coli phage virus when operated for 120 minutes. It was validated that evaluation on the influenza virus could be speculated from the results on the phage according to the test results in a 200 Litre test chamber. It appeared that the air-conditioners in a larger test room (25m³) would be able to remove the influenza virus as effectively as the phage. The AC with nanoe-G was operated in a test room (25m³) and aerosol was collected and fungal spores count was calculated.

TARGET SUBSTANCE

ADHESIVE ODOURS

DEACTIVATES

99

%*3 BACTERIA and VIRUSES

DEODORISES ADHESIVE ODOUR (TOBACCO SMELL)

INHIBITS MOULD GROWTH

*³ Adhesive Deactivation was certified by Japan Food Research Laboratories

Adhesive odour deodorisation was certified by OMI ODOR-AIR SERVICE Co. Ltd.

• Test Report number : 11047933001-02 Bacteria : Staphylococcus aureus (NBRC 12732) • Test Report number : 11073649001-02 Virus : Bacteriophage (Phi X 174 NBRC 103405) • Test Report number : 11047937001-02 Mould : Cladosporium cladosporioides (NBRC 6348)

• Test Report No. 13-1204

All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.


22 | 23

i A U TO - X

34 - 35

nano e-G

TEST REPORT NO

METHOD

RESULT

Test Report No. 12037932001

The test piece impregnated with Staphylococcus aureus was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, viable cells were counted. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.

99% of deactivation after 2-hour nanoe-G operation.

Test Report No. 12014705001

The test piece impregnated with Escherichia coli phage was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, phage infectivity titer was determined. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.

T E C H N I C A L E X P L A N AT I O N

IN-FILTER DEACTIVATION

HOW DOES IN-FILTER DEACTIVATION WORK?

TARGET SUBSTANCE

Bacteria

SUBSTANCE NAME

Staphylococcus aureus (NBRC 12732)

Escherichia coli phage (øX-174 ATCC 13706-B1)

EFFECTIVENESS

99%

99%

TESTING INSTITUTE

Japan Food Research Laboratories

Japan Food Research Laboratories

99% of deactivation after 2-hour nanoe-G operation.

Virus

1. POWER “OFF”

2. FAN OPERATION

The air-conditioner first has to be turned off.

The fan operation will run automatically for 30 minutes with the flaps slightly open to ensure the internal components are dry and free from condensation.

Remark: Main power must be switched on for the entire duration.

Remark: The 30-minute fan operation is only applicable when the unit has been operated in COOL /DRY mode.

Fan Operation : On Flap : Flaps slightly open nanoe-G LED : On

Influenza (H1N1) 2009 Virus

Average 90% on filter (The percentage varies from 78.9% to 96.1% depending on its location)

99 Natural Ion Wind spreads nanoe-G particles that are released from the nanoe-G generator.

nanoe-G deactivates bacteria and viruses that are trapped in the filter within 2 hours.

Fan Operation : Off Flap : Closed nanoe-G LED : On

Remark: Depending on the Air Conditioner’s accumulated operation time, nanoe-G In-Filter Deactivation may be activated only once a day.

Average 90% deactivation after 2-hour nanoe-G operation. (The percentage varies from 78.9% to 96.1%, depending on its location on filter)

IN-FILTER DEACTIVATION

%*4

4. DEACTIVATION EFFECT

KRCES-Virus Test Report No. 24_0013

Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

DEACTIVATES

3. nanoe-G OPERATION

Kitasato Research Center for Environmental Science

The test piece impregnated with Influenza (H1N1) 2009 Virus was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, virus infectivity titer was determined. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.

BACTERIA and VIRUSES

INHIBITS MOULD GROWTH

*⁴ In-Filter Deactivation was certified by Japan Food Research Laboratories • Test Report number : 12037932001 Bacteria : Staphylococcus aureus (NBRC 12732) • Test Report number : 12014705001 Virus : Escherichia coli phage (φΧ-174 ATCC 13706-B1) All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.

DEACTIVATES AVERAGE

9O%

INFLUENZA (H1N1) 2009 VIRUS

In-Filter Deactivation was certified by Kitasato Research Center for Environmental Science • Test Report number : KRCES-Virus Test Report No. 24_0013 Virus : Influenza (H1N1) 2009 Virus All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.


36 - 37

i A U TO T E C H N I C A L E X P L A N AT I O N

SINE WAVE DRIVE iAUTO utilises high efficient Sine Wave DC motor to realise both powerful cooling and energy saving. SINE WAVE COMPARISONS

- COOLING COMFORT Equipped with the Automatic Intelligence to switch between fan speeds, iAUTO gives you up to 15% faster cooling at start up with consistent airflow and automatic fan speed.

Sine Wave (blue) curves smoothly compared to conventional rectangle (grey)

Sine Wave drive produces smooth wave curves.This reduces power loss or energy waste. Conventional rectangle drive produces distortions which results in power efficiency loss.

ADVANTAGES OF SINE WAVE

Reduced current distortion enables fan motor to start faster, run cooler and perform more efficiently even while running at super high fan speed to help reduce power consumption.

MOTOR EFFICIENCY DATA (EX. INDOOR UNIT) 80 75 Efficiency (%)

1. EFFICIENCY UP EVEN AT HIGH ROTATIONAL SPEED PER MINUTE (RPM)

70 65 60 300

2. STABLE OPERATION

500

700

900

1100

1300

1500

Speed (r/min)

Sine Wave regulates power voltage that is identical to power supplied, ensuring consistent performance and stable operation.

Legend:

Sine Wave

Conventional rectangle

3. LOW VIBRATION Motor loads runs smoother with low vibrations resulting in quieter operation. QUALITY CONTROL THROUGH SIMULATED LABORATORY TEST

TRUE COMFORT IS JUST A TOUCH AWAY 1. FAST COOLING AT START UP 2014 model iAUTO mode

29ºC

2013 cool mode with High Fan

At start up, iAUTO will run at super high fan speed to cool the room faster, 15% faster for cooler comfort.

Quick

2. MAINTAIN COOLING COMFORT

25ºC

Super High High Medium

Fan Speed

Room Temperature

35ºC

Time

Once the room cools down, iAUTO provides constant cool airflow to maintain a comfortable level of relative humidity, to stay cool and comfortable all day long.

Panasonic carried out testing at our own Environmental Testing Room which simulates a standard living room condition. This makes it possible to ensure air conditioner operates at optimum performance level under varying conditions. Testing is done in a large space of 16.6m² to simulate size of actual living room. Indoor temperature is measured using 150 sensors to get the average room temperature. This ensures accuracy of indoor temperature data.

16.6m²

* Comparison of 1.5HP Deluxe non-Inverter model with iAUTO mode and cooling mode iAUTO Mode iAUTO Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature: 25˚C with Fan Speed: Auto Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight

3. AUTOMATIC FAN SPEED iAUTO automatically switches fan speed to high and super high fan speed depending on the temperature difference between the room and the set temperature.

150 SENSORS

FASTER COOLING

Cooling Mode with High Fan COOL Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature : 25˚C with Fan Speed High Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight The cooling speed was calculated by measuring the time to reach the setting temperature. At Panasonic Amenity Room (size: 16.6m²) The effect differs according to conditions in installation and usage.

* Applicable to Standard Inverter, Standard non-Inverter & Semi Deluxe non-Inverter.


38 - 39 WALL-MOUNTED :

P R O D U CT L I N E - U P

Single-Split Type

ELITE

BACKLIT SKY CONTROLLER Enjoy innovative design at your fingertips with the new stylish and sleek Backlit Sky Controller. With fast access to key operations and a smooth gliding cover revealing more options, controlling your settings has become simple and intuitive.

CS-VS10SKH | CS-VS13SKH | CS-VS18SKH

Wireless

With a width of 58.9mm and a length of 164.7mm, the Sky Controller fits comfortably into your hand.

Wired (Optional)

(CS-VS10SKH)

SPECIFICATIONS

COOLING MODELS

MODEL

Cooling Capacity EER

Electrical Data

(50Hz)

(min-max)

kW

(min-max)

Btu/h

(min-max)

Btu/hW

Noise Level

2.85 (0.84-3.28)

3.66 (0.92-4.20)

5.20 (1.10-5.80)

9,720 (2,860-11,200)

12,500 (3,140-14,300)

17,700 (3,750-19,800)

13.5 (12.71-12.44)

13.16 (12.08-12.12)

12.21 (12.93-11.72)

V 3.5 - 3.2

4.6 - 4.2

7.0 - 6.4

Power Input (min-max)

W

720 (225-900)

950 (260-1,180)

1,450 (290-1,690)

1.7

2.1

2.9

3.6

4.4

6.1

Indoor

m3/min (ft3/min)

(Pt/h)

10.1 (355)

12.0 (425)

13.4 (475)

Outdoor

m3/min (ft3/min)

21.6 (760) - 22.9 (810)

29.0 (1,020) - 29.6 (1,040)

34.9 (1,230) - 34.9 (1,230)

Indoor (H / L / Q-Lo)

dB (A)

36/25/18 - 36/25/18

41/27/19 - 41/27/19

46/36/31 - 46/36/31

Outdoor (H / L)

dB (A)

(47) - (48)

(48) - (49)

(49) - (50)

Width

mm

318 (511)

318 (542)

318 (619)

inch

12-17/32 (20-1/8)

12-17/32 (21-11/32)

12-17/32 (24-3/8)

mm

950 (650)

950 (780)

950 (824)

inch

37-13/32 (25-19/32)

37-13/32 (30-23/32)

37-13/32 (32-15/32)

mm

280 (230)

280 (289)

280 (299)

inch

11-1/32 (9-1/16)

11-1/32 (11-13/32)

11-1/32 (11-25/32)

Indoor

kg (lb)

Outdoor

kg (lb)

Refrigerant Pipe Diameter Gas Side

Backlit LED screen lets you view operations status in the dark.

2

Power Button.

3

iCOMFORT lets you come home to fast cooling. Then enjoy continuous comfort with RADIANT COOLING which avoids direct cooling.

DUST SENSOR

RADIANT COOLING

4

Press up or down to set the temperature.

5

Toggles between RADIANT COOLING (SHOWER) and Fast Cooling (DIRECT).

220 - 240

L/h

Liquid Side

Pipe Extension

[CU-VS18SKH]

A

Depth

Net Weight

CS-VS18SKH

[CU-VS13SKH]

Current

Height

Dimensions

CS-VS13SKH

[CU-VS10SKH]

Voltage

Moisture Removal

Air Circulation

CS-VS10SKH

1

(Random)

CS-VS10SKH/ CS-VS13SKH

CS-VS18SKH

(Optional)

6

Activates the nanoe-G even when the air conditioner is switched off.

7

Set the airflow.

8

Adjusts the fan speed.

9

Toggles between COOL and DRY setting mode.

10 Delays off timer with temperature

control for better sleep.

13 (29) 21 (46)

29 (64)

mm

6.35

inch

1/4

33 (73)

24-hour Dual ON & OFF Timer.

mm

9.52

12.70

inch

3/8

1/2

12 Set the actual time [hour and

minute].

Chargeless Pipe Length

m

7.5

10

Maximum Pipe Length

m

15

30

Maximum Elevation Length

m

5

Additional Refrigerant Gas**

g/m

20 15 Indoor

Power Supply

Caution For CS-VS10/VS13/VS18SKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. * When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

OUTDOOR CU-VS10SKH

CU-VS13SKH

11 Set the 24-hour ON & OFF Timer or

CU-VS18SKH

1

2 3 4

5

6

7

8 10

9

11

12


40 - 41 WALL-MOUNTED : PREMIUM

P R O D U CT L I N E - U P

Single-Split Type

EASY-TO-USE REMOTE CONTROLLER

Wireless

CS-S10RKH | CS-S13RKH

CS-S18RKH | CS-S24RKH | CS-S28RKH

Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.

Wired (Optional)

Wireless

(

Cooling Capacity

(min-max) (min-max)

CS-S28RKH

[CS-S10RKH]

[CS-S13RKH]

[CS-S18RKH]

[CS-S24RKH]

[CS-S28RKH]

9,720 (2,860-11,200)

12,500 (3,140-14,300)

18,100 (3,750-20,500)

21,300 (3,820-24,200)

24,200 (3,920-29,000)

2.85 (0.84-3.28)

3.67 (0.92-4.20)

5.30 (1.10-6.00)

6.25 (1.12-7.10)

7.10 (1.15-8.50)

13.3

12.4

12.6

11.3

11.9

8.8 - 8.2

9.6 - 9.0

3.6 - 3.3

5.1 - 4.6

7.0 - 6.4

W

730 (225-920)

1,010 (260-1,200)

1,440 (290-1,700)

1,880 (320-2,200)

2,030 (350-2,700)

L/h

1.7

2.1

2.9

3.5

4.1

Pt/h

3.6

4.4

6.1

7.4

8.7

Indoor

m³/min.

10.1

10.9

17.7

18.1

18.4

Outdoor

ft³/min.

355

385

625

640

650

Indoor (H/L/Q-Lo)

(dB-A)

36/26/23 - 36/26/23

38/28/25 - 38/28/25

44/32/29 - 44/32/29

45/34/31 - 45/34/31

47/37/34 -

Outdoor (H/L)

(dB-A)

Width

Net Weight

Liquid Side Refrigerant Pipe Diameter Gas Side

(46) - (47)

(47) - (48)

(49) - (50)

(51) - (52)

(52) - (53)

mm

296 (511)

296 (542)

296 (619)

296 (695)

296 (795)

inch

11-21/32 (20-1/8)

11-21/32 (21-11/32)

11-21/32 (24-3/8)

11-21/32 (27-3/8)

11-21/32 (31-5/16)

mm

870 (650)

870 (780)

1,070 (824)

1,070 (875)

inch

34-9/32 (25-19/32)

34-9/32 (30-23/32)

42-5/32 (32-15/32)

42-5/32 (34-15/32)

mm

236 (230)

236 (289)

241 (299)

241 (320)

inch

9-15/16 (9-1/16)

9-15/16 (11-13/32)

9-1/2 (11-25/32)

9-1/2 (12-5/8)

3

ECONAVI monitors sunlight intensity, human movement, activity levels and human absence to detect and reduce energy waste.

4

Activates the nanoe-G function even when the air conditioner is switched off.

5

Press up or down to set the temperature.

6

1

3

2 5

6

Toggles between iAUTO-X, COOL and DRY setting mode.

10

9

(Random)

CS-S10RKH/ CS-S13RKH

(Optional)

CS-S18RKH/ CS-S24RKH

CS-S28RKH

7 Auto comfort mode detects high activity levels and switches to comfort operation for maximum comfort.

11 12

8

Set the airflow.

9

Adjusts the fan speed.

10 Quiet function allows you to sleep

comfortably at night. Wireless Applicable to PREMIUM Inverter

11 Set the 24-hour ON & OFF Timer or

12 Set the actual time (hour and

minute).

9 (20)

9 (26)

12 (34)

12 (46)

12 (57)

lb

20 (44)

20 (57)

26 (75)

26 (101)

26 (126)

DUAL TIMER

ø 6.35

mm

1/4

inch ø 9.52

ø 12.70

ø 15.88

3/8

1/2

5/8

inch

DUAL TIMER FOR 2 ON AND OFF TIMES PER DAY

10

Chargeless Pipe Length

m

7.5

Maximum Pipe Length

m

15

20

30

Maximum Elevation Length

m

5

15

20

Additional Refrigerant Gas**

g/m

20

15

Power Supply

For convenience, the dual timer repeats everyday until you cancel it.

30 Outdoor

Indoor

Select ON or OFF Timer

Caution For CS-S10/S13/S18/S24/S28RKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. * When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

1

2

1

Cancel

OUTDOOR CU-S10RKH

CU-S13RKH

CU-S18RKH

CU-S24RKH

4 8

7

24-hour Dual ON & OFF Timer.

kg

mm

Come home to fast cooling. Then enjoy continuous comfort with Shower Cooling which avoids direct cooling.

C

220 - 240

A

Depth

Pipe Extension

CS-S24RKH

Running Current

Height

Dimensions

CS-S18RKH

V

Moisture Removal

Noise Level

CS-S13RKH

Voltage

Power Input

Air Circulation

kW

CS-S10RKH

Btu/hW

EER

Electrical Data

Btu/h

2

): Outdoor Unit

COOLING MODELS (50Hz)

LCD display for an easy overview of the operation status.

Wired (Optional)

SPECIFICATIONS MODEL

1

CU-S28RKH

Set the time. TIMER

2

Cancel


42 - 43

P R O D U CT L I N E - U P

WALL-MOUNTED : DELUXE NON-INVERTER Single-Split Type

EASY-TO-USE REMOTE CONTROLLER Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.

Wireless

CS-C9RKH | CS-C12RKH

CS-C18RKH | CS-C24RKH | CS-C28RKH

(

Cooling Capacity EER

Electrical Data

[CS-C12RKH]

[CS-C18RKH]

[CS-C24RKH]

[CS-C28RKH]

18,400 - 18,400

24,000 - 24,000

26,900 - 27,300

kW

2.65 - 2.70

3.52 - 3.57

5.40 - 5.40

7.03 - 7.03

7.90 - 8.00

Btu/hW

11.3 - 11.0

10.8 - 10.6

10.5 - 10.0

10.2 - 9.7

9.9 - 9.9

11.0 - 11.1

12.6 - 12.0

5.2 - 5.2

8.5 - 8.4

W

800 - 835

1,110 - 1,150

1,750 - 1,850

2,350 - 2,470

2,720 - 2,760

L/h

1.6

2.1

2.9

4.0

4.7

Pt/h

3.4

4.4

6.1

8.5

9.9

Indoor

m³/min.

9.8

10.8

16.4

18.2

20.2

Outdoor

ft³/min.

346

381

579

642

713

Indoor (H/L/Q-Lo)

(dB-A)

36/26 - 36/26

39/29 - 29/29

43/37 - 43/37

46/40 - 46/40

49/44 - 49/44

Outdoor (H/L)

(dB-A)

(46) - (47)

(48) - (49)

Net Weight

Liquid Side Refrigerant Pipe Diameter Gas Side

(53) - (54)

(54) - (55)

(55) - (56)

mm

296 (511)

296 (542)

296 (695)

296 (750)

inch

11-21/32 (20-1/8)

11-21/32 (21-11/32)

11-21/32 (27-3/8)

11-21/32 (29-17/32)

mm

870 (650)

inch

34-9/32 (25-19/32)

1,070 (780)

1,070 (875)

42-5/32 (30-23/32)

42-5/32 (34-15/32)

236 (230)

241 (289)

241 (320)

241 (345)

inch

9-5/16 (9-1/16)

9-1/2 (11-13/32)

9-1/2 (12-5/8)

9-1/2 (13-19/32)

kg

9 (21)

9 (25)

12 (34)

12 (52)

12 (62)

lb

20 (46)

20 (55)

26 (75)

26 (115)

26 (137)

mm

ø 6.35

inch

1/4

inch

Chargeless Pipe Length

m

Maximum Pipe Length

m

Maximum Elevation Length

m

Additional Refrigerant Gas**

g/m

Power Supply

ECONAVI monitors sunlight intensity, human movement, activity levels and human absence to detect and reduce energy waste.

ø 12.70

ø 15.88

3/8

1/2

5/8

30

25

20 Indoor

(Random)

CS-C12RKH

CS-C18RKH/ CS-C24RKH

CS-C28RKH

6

10

CS-C9RKH

8

Set the airflow.

9

Adjusts the fan speed.

11 12

comfortably at night. Wireless Applicable to Deluxe non-Inverter

11 Set the 24-hour ON & OFF Timer.

minute).

2

3

ON

OFF

SET

2

33 CANCEL CAN CEL

Select ON or OFF Timer

Example: OFF at 22:00 OFF

* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

Set the time. 2

OUTDOOR CU-C9RKH CU-C12RKH

CU-C18RKH

CU-C24RKH

CU-C28RKH

9

10 Quiet function allows you to sleep

1

Outdoor

4 8

7 Auto comfort mode detects high activity levels and switches to comfort operation for maximum comfort.

30 Indoor

Indoor

5

7

Toggles between iAUTO, COOL and DRY setting mode.

1

20

10

Press up or down to set the temperature.

TIMER

5

Indoor

5

3

2

To turn the unit ON or OFF at a preset time.

7.5 15

Activates the nanoe-G function even when the air conditioner is switched off.

TO SET THE TIMER

ø 9.52

10

4

1

12 Set the actual time (hour and

mm

mm

3

6

220 - 240 3.8 - 3.7

Width

Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.

CS-C28RKH

12,000 - 12,200

A

Depth

Pipe Extension

CS-C24RKH

9,040 - 9,210

Running Current

Height

Dimensions

CS-C18RKH

V

Moisture Removal

Noise Level

CS-C12RKH

Voltage

Power Input

Air Circulation

CS-C9RKH [CS-C9RKH]

Btu/h

2

): Outdoor Unit

COOLING MODELS (50Hz)

LCD display for an easy overview of the operation status.

Wireless

SPECIFICATIONS MODEL

1

Confirm. TIMER

SET


44 - 45

P R O D U CT L I N E - U P

WALL-MOUNTED : STANDARD NON-INVERTER Single-Split Type

EASY-TO-USE REMOTE CONTROLLER

CS-PC9QKH | CS-PC12QKH

Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.

Wireless

CS-PC18QKH | CS-PC24QKH | CS-PC28QKH

Cooling Capacity EER

Electrical Data

Air Circulation

Noise Level

CS-PC12QKH

CS-PC18QKH

CS-PC24QKH

CS-PC28QKH

(CU-PC9QKH)

(CU-PC12QKH)

(CU-PC18QKH)

(CU-PC24QKH)

(CU-PC28QKH)

Btu/h

9,040 - 9,210

11,900 - 12,100

18,000 - 18,100

23,600 - 24,000

26,900 - 27,300

kW

2.65 - 2.70

3.49 - 3.54

5.28 - 5.30

6.93 - 7.03

7.90 - 8.00

Btu/hW

10.7 - 10.4

10.2 - 10.0

9.4 - 9.1

9.2 - 8.9

9.0 - 9.0

4.4 - 4.3

5.5 - 5.6

8.9 - 9.0

12.2 - 12.1

14.0 - 13.1

Power Input

W

845 - 885

1,170 - 1,210

1,920 - 1,980

2,570 - 2,700

2,990 - 3,040 4.7

L/h

1.6

2.1

2.9

4.0

Pt/h

3.4

4.4

6.1

8.5

9.9

Indoor

m³/min.

8.9

11.1

16.4

18.7

20.2

Outdoor

m³/min.

324

392

579

660

713

Indoor (H/L)

(dB-A)

37/26 - 37/26

40/29 - 40/29

43/39 - 43/39

47/42 - 47/42

50/46 - 50/46

Outdoor (H/L)

(dB-A)

(50)

Width

Net Weight

Liquid Side Refrigerant Pipe Diameter Gas Side

(53)

(56)

(60)

(55)

mm

290 (511)

290 (542)

290 (695)

290 (750)

inch

11-7/16 (20-1/8)

11-7/16 (21-11/32)

11-7/16 (27-3/8)

mm

850 (650)

1,070 (780)

inch

33-15/32 (25-19/32)

42-5/32 (30-23/32)

mm

199 (230)

240 (289)

240 (320)

235 (345)

inch

7-27/32 (9-1/16)

9-15/32 (11-13/32)

9-15/32 (12-5/8)

9-9/32 (13-19/32)

8 (22)

8 (24)

12 (34)

12 (52)

12 (63)

18 (53)

26 (75)

26 (115)

26 (139)

mm

ø 6.35

inch

1/4

mm

ø 9.52

ø 12.70

inch

3/8

1/2

m

Maximum Elevation Length

m

Additional Refrigerant Gas*

g/m

4

Set the airflow.

5

Press up or down to set the temperature.

1

Optional

6

Set the 24-hour ON & OFF Timer.

2 5

10

CS-PC9QKH

CS-PC12QKH

4

6

CS-PC18QKH/ CS-PC24QKH

CS-PC28QKH

Wireless Applicable to Standard non-Inverter

TO SET THE TIMER To turn the unit ON or OFF at a preset time. 1

2

ON

1 OFF

ø 15.88

3 SET

2

33 CANCEL CAN CEL

5/8 Select ON or OFF Timer

15

Example: OFF at 22:00

30

25

5

OFF

20

10

20 Indoor

30

Indoor

Indoor

Set the time. Outdoor

* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.

2

Confirm. TIMER

OUTDOOR CU-PC9QKH CU-PC12QKH

3

Random

TIMER

7.5

Indoor

Power Supply

Adjusts the fan speed.

42-5/32 (34-15/32)

18 (49)

Maximum Pipe Length

3

11-7/16 (29-17/32)

lb

m

Toggles between iAUTO, COOL, and DRY setting mode.

1,070 (875)

kg

Chargeless Pipe Length

2

220 - 240

V A

Depth

Pipe Extension

CS-PC9QKH

Running Current

Height

Dimensions

(50Hz)

Voltage

Moisture Removal

Automatic intelligence switches fan speed for faster cooling.

Wireless

SPECIFICATIONS MODEL

1

CU-PC18QKH

CU-PC24QKH

CU-PC28QKH

SET


46 - 47

F E AT U R E S C O M PA R I S O N Split Type

F E AT U R E S E X P L A N AT I O N

ELITE Inverter

PREMIUM Inverter

DELUXE Non-Inverter

STANDARD Non-Inverter Wall-Mounted

Cooling Models

CS-VS10SKH CS-VS13SKH CS-VS18SKH

CS-S10RKH CS-S13RKH

CS-S18RKH CS-S24RKH CS-S28RKH

CS-C9RKH CS-C12RKH

CS-C18RKH CS-C24RKH CS-C28RKH

CS-PC9QKH CS-PC12QKH

CS-PC18QKH CS-PC24QKH CS-PC28QKH

RADIANT COOLING

TEMPERATURE WAVE

C

Rhythmic temperature-controlled pattern to save energy without sacrificing comfort.

Come home to fast cooling. Then enjoy continuous comfort with Shower Cooling which avoids direct cooling.

SLEEP MODE

Delays off timer with temperature control for better sleep.

Detects and reduces waste for more energy savings.

SLEEP

AUTOCOMFORT

AIRFLOW DIRECTION CONTROL (UP & DOWN)

PERSONAL AIRFLOW CREATION

iCOMFORT

Vertical and horizontal airflow patterns can be combined as desired to achieve optimum comfort, with operation possible by remote even from a distance.

Temperature Wave AUTOCOMFORT

Varies the rotation speed of the compressor for higher energy savings.

SOFT DRY OPERATION MODE

Detects high activity levels and adjusts cooling power to improve comfort.

* Fast Cooling. Refer to Page 8-9

INVERTER CONTROL

QUIET MODE

Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.

ECONAVI

SLEEP

Cools the ceiling and walls first, providing continuous cooling comfort without direct airflow.

ECONAVI

iAUTO-X

RADIANT COOLING

Starts with cooling to dehumidify, then provides continuous breeze at a low frequency to keep a room dry without much change to the temperature.

Radiant Cooling

iAUTO-X

C

COMFORT

iAUTO

COMFORT RADIANT COOLING

F E AT U R E S C O M PA R I S O N & E X P L A N AT I O N

MANUAL HORIZONTAL AIRFLOW DIRECTION CONTROL

Lets you come home to fast cooling. Then enjoy continuous comfort with RADIANT COOLING which avoids direct cooling.

CLEANER AIR

SLEEP Inverter Control

nanoe-G

DUST SENSOR

nanoe-G works effectively on airborne particles including PM2.5, adhesive and in-filter micro-organisms such as bacteria, viruses and mould ensuring a cleaner living environment.

iAUTO Quiet Mode Soft Dry Operation Mode

Monitors particle concentration levels and turns on nanoe-G if levels are high.

REMOVABLE, WASHABLE PANEL

ODOUR-REMOVING FUNCTION

With this function, there's no unpleasant odor when the unit starts up. That's because the fan remains off momentarily, while the source of the odour inside the air conditioner is suppressed.

Personal Airflow Creation Airflow Direction Control (Up & Down)

CLEANER AIR

24-HOUR DUAL ON & OFF REAL SETTING TIMER

nanoe- G

24-HOUR ON & OFF REAL SETTING TIMER

This feature enables you to preset two different sets of start/stop operation timer (hour and minute) within a 24-hour time frame.

Dust Sensor Anti-Bacterial Filter

(Optional)

The exact operating time (hour and minute) of the air conditioner can be set in advance. From here on, the unit will operate in accordance to these preset hours every day until the system is reset.

LONG PIPING

RANDOM AUTO RESTART

Anti-Dust Coating

24-Hour Dual ON & OFF Real Setting Timer

TOP-PANEL MAINTENANCE ACCESS

24-Hour ON & OFF Real Setting Timer

SELF-DIAGNOSTIC FUNCTION Should a malfunction occur, the unit diagnoses the problem and shows the corresponding alphanumeric code. This allows for quicker servicing.

LCD Wireless Remote Control

(Optional)

(Optional)

OPTIONAL ACCESSORIES

(Optional)

RELIABILITY

REMOTE CONTROL

Random Auto Restart (32 Restart Patterns)

Wired Remote Control

FILTER Anti-Bacterial Filter

Blue Fin Condenser

Self-Diagnostic Function

WIRED REMOTE CONTROL

BLUE FIN CONDENSER

(Random)

CONVENIENCE

Top-Panel Maintenance Access

LCD WIRELESS REMOTE CONTROL

RELIABILITY

Removable, Washable Panel

Long Piping (Numbers indicate the maximum pipe length)

Anti-dust coating prevents dust from accumulating on cross flow fan by keeping it clean.

(Optional)

Odour-Removing Function

(Random)

ANTI-DUST COATING

CONVENIENCE

iCOMFORT

Wired Remote Control

The Anti-Bacterial Filter combines three effects in one: anti-allergen, anti-virus and anti-bacterial protection to provide clean air.

The unit must be in cool or dry mode and the fan speed must be set to automatic.

Manual Horizontal Airflow Direction Control

DUST SENSOR

ANTI-BACTERIAL FILTER DUST SENSOR

15m (VS10/VS13) 30m (VS18)

15m

20m (S18/S24) 30m (S28)

10m (C9) 15m (C12)

25m (C18/C24) 30m (C28)

10m (PC9) 15m (PC12)

25m (PC18/PC24) 30m (PC28)

CZ-RD514C CS-VS10SKH, CS-VS13SKH, CS-VS18SKH, CS-S10RKH, CS-S13RKH, CS-S18RKH, CS-S24RKH, CS-S28RKH

CZ-SA22P CS-PC9QKH, CS-PC12QKH, CS-PC18QKH, CS-PC24QKH, CS-PC28QKH


48 - 49

MODEL LINE-UP Capacity (Btu/h)

9,000 / 10,000

12,000 / 13,000

18,000

24,000

INVERTER DELUXE

28,000 FEATURES

INVERTER DELUXE

Wall-Mounted

ELITE INVERTER Page 38-39

CS-VS10SKH

CS-VS13SKH

CS-VS18SKH

(CU-VS10SKH)

(CU-VS13SKH)

(CU-VS18SKH)

(CS-VS10SKH)

DELUXE

DELUXE WIDE

FEATURES

Wall-Mounted

PREMIUM INVERTER Page 40-41

CS-S10RKH

CS-S13RKH

CS-S18RKH

CS-S24RKH

CS-S28RKH

(CU-S10RKH)

(CU-S13RKH)

(CU-S18RKH)

(CU-S24RKH)

(CU-S28RKH)

STANDARD

STANDARD WIDE

FEATURES

Wall-Mounted

DELUXE Page 42-43

CS-C9RKH

CS-C12RKH

CS-C18RKH

CS-C24RKH

CS-C28RKH

(CU-C9RKH)

(CU-C12RKH)

(CU-C18RKH)

(CU-C24RKH)

(CU-C28RKH)

STANDARD

STANDARD WIDE

FEATURES

Wall-Mounted

STANDARD Page 44-45

( ): Outdoor Unit

CS-PC9QKH

CS-PC12QKH

CS-PC18QKH

CS-PC24QKH

CS-PC28QKH

(CU-PC9QKH)

(CU-PC12QKH)

(CU-PC18QKH)

(CU-PC24QKH)

(CU-PC28QKH)

Cooling Models

P R O D U CT L I N E - U P


50 - 51

MEMO

MEMO


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.