AIR CONDITIONER 2016/2017
A I R CO N D I T I O N E R
Please read the Installation Instructions carefully before installing the unit, and the Operating Instructions before using it. Specifications are subject to change without prior notice. The contents of this catalogue are accurate as of January 2016. Due to printing considerations, the actual colours may vary slightly from those shown. All graphics are provided merely for the purpose of illustrating a point.
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
AC-ASIA-C-16
02 - 03
THE FUTURE IS UP 1958 marked the start of Panasonic’s venture into creating air conditioners through cutting edge technology. Today, we bring you a quantum leap in design and performance, creating a new standard for how all air conditioners will be made. Peerless design. Powerful cooling. Perfect comfort.
CONTENT
02 - 03
10 - 11
18 - 21
30 - 35
The Future Is Up
RADIANT COOLING
04 - 05
12 - 13
22 - 23
36 - 37
The Benefits of RADIANT COOLING
Technical Explanation
Technical Explanation
14 - 15
24 - 27
38 - 45
Kai Ken Bi
06 - 07 SKY STREAM DESIGN
08 - 09
SKYWING
Technical Explanation
& DUST SENSOR
16 - 17
Backlit SKY Controller
28 - 29
+
Model Line Up ELITE Inverter Single-Split PREMIUM Inverter Single-Split Deluxe non-Inverter Single-Split Standard non-Inverter Single-Split
46 - 47
Features Comparison and Explanation
48 - 49
Model Line Up
THE FUTURE IS UP
04 - 05
COMFORT Essential air conditioner functions that cool you the way you want.
KAI
HEALTH Clean and fresh air that improves your health and wellbeing.
KEN
THE PHILOSOPHY OF PANASONIC AIR CONDITIONER COMPANY At Panasonic Air Conditioner Company, we’re constantly finding new ways to improve your life. Our innovations bring you comfort when you need it most, take care of your health and beautify your homes and lives.
BEAUTY Minimalist and modern air conditioners that beautify your homes.
BI
KAI KEN BI
06 - 07
SKY STREAM DESIGN - FORM & FUNCTION UP The SKY STREAM design embodies the elegance and pursuit of perfection inherent in Japanese design philosophy. Each timeless, precise line and feature creates an unmistakable impression of premium luxury. Yet the true power of its design is only revealed when it is switched on.
MODERN & MINIMALIST LINES Sleek and striking design that makes it a luxurious complement to designer interior.
MULTIDIRECTIONAL ARM Experience better agility through better control with a multidirectional arm that adjusts cooling the way you want it.
SLIDING LED PANEL When switched on, the Sliding LED Panel slides open to reveal its setting indicators.
SKY STREAM DESIGN
08 - 09
SKYWING
SKYWING - FLEXIBILITY UP The new SKYWING is set to create a new standard in air conditioner design. Located at the top, the SKYWING is better able to direct cool air towards the ceiling. This cool air naturally glides along the surface, spreading throughout the room and down the walls. Heat is removed from the ceiling and walls, resulting in a feeling of even, all-round coolness – RADIANT COOLING.
MULTIDIRECTIONAL ARM
Controlled by a Multidirectional Arm, the SKYWING can cool you two ways: RADIANT COOLING
FAST COOLING
VERSATILE COOLING COMFORT WITH SKYWING
The SKYWING angles upwards to direct cool air towards the ceiling and walls, spreading cool air gently and evenly throughout the room.
The SKYWING angles downward to provide you fast cooling at start up. Together with the high-powered Inverter compressor technology, P-TECh, SKY Series gives you extreme cool air with extra fast speed.
At the touch of a button, the SKYWING tilts down for you to enjoy Panasonic’s powerful and efficient Fast Cooling whenever you need to cool down quickly. Experience more powerful cooling from the moment you switch on the air conditioner. Once the room has reached the set temperature, the SKYWING will adjust to RADIANT COOLING for continuous comfort.
* Applicable to ELITE Inverter only.
10 - 11
RADIANT COOLING
RADIANT COOLING
2 1
- ALL-ROUND COOLING UP Ceilings and walls tend to trap heat, which make living spaces inside hot and uncomfortable. The solution was inspired by a scientific principle called the Coanda Effect.
4 3
THE PRINCIPLE OF THE COANDA EFFECT
The Coanda Effect is the tendency of airflow to be drawn to a surface and to flow along it.
RADIANT COOLING AIRFLOW ASSESSMENT AIRFLOW SMOKE TEST
Here is how RADIANT COOLING works:
TEMPERATURE DISTRIBUTION TEST
BOTTOM AIR INTAKE
4 The room is evenly cooled down.
Instead of blowing cold air directly onto people, the SKYWING directs the airflow upwards to cool the ceiling and walls.
CONVENTIONAL AIR CONDITIONER
RADIANT COOLING
Cold air blows downward, leaving some parts of the room warmer and others colder.
By cooling the ceiling and walls first, comfortable cooling spreads evenly across the room.
Hot air is drawn in from the bottom, and cool air discharged from the top to facilitate the even distribution of cool air.
3 Heat trapped in the ceiling and walls is removed.
2 Cool air is evenly distributed throughout the room.
1 Cool air is directed towards the ceiling.
RADIANT COOLING cools without direct airflow. The feeling is just like walking into a mall.
* Applicable to ELITE Inverter only.
12 - 13
THE BENEFITS OF RADIANT COOLING
Conventional air conditioner
RADIANT COOLING FOR USERS’ COMFORT COOLING - BENEFITS UP
COOLS GENTLY AND EVENLY The SKY Series makes the room evenly cool, even though no airflow feeling. The cooling system of SKY Series gives comfort based on the principleof RADIANT COOLING. 28 27 26 25 24 23 22 21 20 19 18 17
Temperature distribution
28 27 26 25 24 23 22 21 20 19 18 17
”It's comfortable!" "It's cold!"
˚C
”It's comfortable!"
"I don’t feel much wind!"
"I feel cold wind!"
Air velocity distribution
Comfortable in living space with no wind (less than 0.2 m/s*)
Discharge airflow
Intake airflow
*Meter per second
No Air Feeling Area
Discharge airflow
Intake airflow
No Air Feeling Area
Inspired by the cooling effect of caves, Doctor Naoshi Kakitsuba investigated the benefits of RADIANT COOLING. He found that this gentler and more even cooling method results in a greater feeling of comfort and wellbeing.
The temperature in all areas of the room can be evenly set at a comfortable level.
˚C
No Air Feeling Area
Conventional air conditioners are built to blow cold air downwards and directly at people to cool them instantly. However, when in direct contact with cold air for too long, some people experience discomfort and dry skin.
DR NAOSHI KAKITSUBA
SKY SERIES
Test conditions: Measured in stable operation at 25˚C cooling with fan speed set at "HI."
RADIANT COOLING REMOVES HEAT FROM CEILING AND WALLS SKY Series makes people comfortable because the radiant heat from ceiling is less.
Average ceiling temperature: 35˚C
Radiant heat from roof top and ceiling
Mean Radiant Temperature (Measure by Globe Thermometer) 26.2˚C
Average room temperature: 25˚C
DEPT. OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, MEIJO UNIVERSITY JAPAN
Average ceiling temperature: 30˚C
Mean Radiant Temperature (Measure by Globe Thermometer) 26.2˚C
Average room temperature: 25˚C
The globe temperature is about 0.8˚C higher (=About 1.1˚C higher in terms of how people feel comfortable) The globe temperature is a composite temperature used to estimate the effect of temperature, humidity, and solar radiation on humans.
Slightly uncomfortable
PRINCIPLE OF RADIANT COOLING THE PRINCIPLE OFTHE RADIANT COOLING
Conventional Cooling
Sensation evaluation
Slightly comfortable Room Temp.
25 ºC
Heat is absorbed by the breeze on the skin, resulting in a cool feeling.
Comfortable
20%
Slightly comfortable Neither or any side
100%
Room Temp.
25 ºC
Comfortable / Slightly comfortable
Slightly comfortable
Conventional air conditioner
Measured in stable operation at 25˚C cooling with fan speed set at "MEDIUM." The actual average room temperature is the same.
The breeze directly contacts the body for cooling.
MAINTAIN SKIN MOISTURE AND PREVENTS DRY SKIN RADIANT COOLING
Heat is absorbed by the cool surrounding walls and ceiling, resulting in a cool feeling.
Skin doesn’t become dry even in a room with SKY Series operating.
SKY SERIES Skin moisture after 60 minutes
60 min.
210μS
150μS
71%
60 min.
210μS
206μS
98%
The breeze cools the walls and ceiling, which absorb the body heat. Measured in stable operation at 25˚C cooling with fan speed set at "HI."
* Applicable to ELITE Inverter only. *All test results are based on internal test.
14 - 15
featuring
nanoe-G
& DUST SENSOR
REMOVES DOWN TO PM2.5
DUST SENSOR
nanoe-G releases negative ions which attach
- HEALTH & WELLBEING UP
to particles as small as PM2.5, the measuring benchmark of air quality monitoring agencies. These particles are then brought back to the positively-charged filter and removed from the air.
SKY Series also features Panasonic’s advanced air purification system, nanoe-G, which now comes with an innovative new DUST SENSOR.
Please refer to page 30 - 31
AUTOMATED ACTIVATION The DUST SENSOR automatically switches on nanoe-G to purify the air whenever a high level of particle concentration is detected.
CONSTANT AIR MONITORING The DUST SENSOR is constantly monitoring particle concentration levels in the room.
LED
ACTIVITY
DUST SENSOR
WHITE
AIR IS CLEAN
nanoe-G
OFF
When particle concentration level is safe, the indicator on the LED panel is white.
LED
ACTIVITY
DUST SENSOR
RED
AIR IS DIRTY
nanoe-G
WHITE
nanoe-G IS ACTIVATED TO PURIFY THE AIR
When particle concentration level is high, the indicator light turns red. nanoe-G switches on to purify the air.
* Applicable to ELITE Inverter only.
16 - 17
BACKLIT SKY CONTROLLER
SKY CONTROLLER - VERSATILE CONTROL UP The remote control has been redesigned for maximum ease of use and to complement the stylish new design for SKY Series. With simple and intuitive controls, the Sky Controller comes with various settings that meet your everyday air conditioning needs.
BACKLIT LED SCREEN The Sky Controller reveals its settings in a better light thanks to the new backlit screen. Now you can adjust your settings without having to switch on the lights.
DISTINCTIVE SLIDING COVER A smooth sliding cover does not only enhance the remote’s clean lines, but keeps the buttons free from dirt and smudges.
PRECISE TEMPERATURE CONTROL With the Sky Controller’s 0.5°C temperature control, enjoy more precise temperature regulation and experience greater comfort.
* Applicable to ELITE Inverter only.
18 - 19
i A U TO - X
- POWER & SPEED UP iAUTO-X provides powerful instant cooling. Joining forces with fast, high-powered inverter control through the use of Panasonic Thermal Enhancement Technology (P-TECh), twin flaps direct the airflow for fast cooling. Delivering this powerful cooling airflow makes possible a 35% reduction in the time required to reach the set temperature.
P-TECh The new Panasonic Thermal Enhancement Technology (P-TECh) enables the compressor to achieve maximum frequency in the shortest time from start up. This lets you enjoy more powerful cooling from the moment you switch on the air conditioner.
P-TECh
HIGHEST FREQUENCY
2015 Panasonic
EQUEN MAX FR DASH T O
Compressor Frequency (Hz)
CY
DASH & HIGH COMPRESSOR FREQUENCY
2014 Panasonic
Time (min.)
* P-TECh is applicable for ELITE Inverter and PREMIUM Inverter only.
20 - 21
i A U TO - X
FA S T C O O L I N G - HAPPINESS IS COMING HOME TO FAST COOLING On a hot day, feel the satisfaction of quick cooling that happens in an instant.
FASTER COOLING
On a hot day, feel the satisfaction of quick cooling that happens in an instant.
iAUTO-X cools you down 35% faster compared to Panasonic Standard non-Inverter model with high fan. Room Temperature 35ºC
AUTOMATIC FAN SPEED iAUTO-X will automatically switch fan speed to high fan speed and super high fan speed depending on the temperature difference between the room and the set temperature.
29ºC
Quick
PREMIUM Inverter with iAUTO-X Standard non-Inverter model with high fan
25ºC
Time
LOW SPEED
MEDIUM SPEED
PREMIUM INVERTER WITH iAUTO-X
STANDARD NON-INVERTER MODEL WITH HIGH FAN
35
HIGH FAN SPEED
%*
SUPER HIGH FAN SPEED
Faster Cooling
* Comparison of 1.5HP PREMIUM Inverter with iAUTO-X mode and Standard non-Inverter model with cooling mode PREMIUM Inverter: iAUTO-X Mode iAUTO-X Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature: 25˚C with Fan Speed: Auto Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight Standard non-Inverter: Cooling Mode with High Fan COOL Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature : 25˚C with Fan Speed High Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight The time to reach the setting temperature was measured. At Panasonic Amenity Room (size: 16.6m²) The effect differs according to conditions in installation and usage.
Remark: Applicable for PREMIUM Inverter with iAUTO-X
warmer
cooler * Applicable to PREMIUM Inverter only.
22 - 23
SHOWER COOLING - COMFORT THAT GOES ON AND ON WITH SHOWER COOLING After reaching the set temperature, Shower Cooling directs airflow towards the ceiling to avoid direct cooling. This helps distribute cool air evenly throughout the room, giving you longer lasting comfort.
i A U TO - X T E C H N I C A L E X P L A N AT I O N
AEROWINGS features twin flaps that give you more control over the direction of the airflow. * Applicable to PREMIUM Inverter, Standard Inverter, Standard non-Inverter & Semi Deluxe non-Inverter.
INNER FLAP
OUTER FLAP
Panasonic Air Conditioners with Aerowings feature an indoor design with wider intake grille and super-high fan speed to produce bigger air volume.
PKT (2014)
RKH (2016)
HOT AIR INTAKE 214mm
MORE HOT AIR INTAKE BIG INTAKE
BIGGER INTAKE
236mm
FAN SPEED HIGH SUPER HIGH*
Panasonic Air Conditioners feature an intake grille which is 22 mm wider and improved indoor fan speed that goes up to a super-high fan speed at start up. The chassis design generates bigger air volume that contributes to faster cooling.
FOR SHOWER COOLING Before you feel too cold and uncomfortable, AEROWINGS shifts the airflow upwards to spread cool air over a wider area. This ensures cool air is evenly distributed throughout the room and you can stay comfortable without experiencing continuous direct cooling.
HONEYCOMB INTAKE GRILLE The Honeycomb Intake Grille has a wider opening to increase the suction of hot air from the room so that the room can be cooled faster. The stronger honeycomb structure also offers the air conditioner better protection. HOT AIR INTAKE
* Applicable to PREMIUM Inverter only.
24 - 25
- ENERGY SAVING
E C O N AV I + I N V E R T E R
COOL. ECO. TOGETHER. With ECONAVI’s Human Activity Sensors and Panasonic INVERTER’s alternating speed frequency, enjoy energy saving highs while experiencing ultimate comfort.
THE PERFECT MATCH FOR HOME LIVING ECONAVI and INVERTER is a perfect match of energy saving features that keeps air conditioning in your home more efficient and comfortable throughout the day.
SAVES YOU MORE ENERGY FOR PEACE OF MIND Your Panasonic Air Conditioner simply knows when to keep power usage at a minimum. So, you can rest and relax comfortably at home knowing that you can save energy.
* Comparison of 1.5HP Inverter model with ECONAVI (with Dual Human Activity Sensor, Sunlight Sensor, and Temperature Wave) ON and 1.5HP Standard non-Inverter (Cooling) Inverter with ECONAVI: ECONAVI ON, Outside Temperature: 35˚C/24˚C Remote setting temperature: 25˚C with Fan Speed High Horizontal Airflow direction: Step 3, Vertical Airflow direction: ECONAVI mode Setting temperature goes up 2˚C in total, 1˚C controlled by ECONAVI activity level detection and another 1˚C controlled by ECONAVI light intensity detection. Temperature Wave is ON Standard non-Inverter without ECONAVI: Outside Temperature: 35˚C/24˚C Remote setting temperature: 25˚C with Fan Speed High Horizontal Airflow direction: Step 3, Vertical Airflow direction: Straight Total power consumption amount is measured for 2 hours under stable operation. At Panasonic Amenity Room (size: 16.6m²) This is the maximum energy saving value, and the effect differs according to conditions in installation and usage.
* Applicable to PREMIUM Inverter only.
26 - 27
ECONAVI SENSORS
E C O N AV I + I N V E R T E R
INVERTER
ECONAVI has two sensors; the Human Activity Sensor and the Sunlight Sensor. Together, they monitor human location, movement, absence, and sunlight intensity to use energy more efficiently.
NON-INVERTER Room Big temperature temperature fluctuations
HUMAN ACTIVITY SENSOR
SUNLIGHT SENSOR
Output power
Set temperature
ON
OFF
ON
OFF
ON
A conventional non-INVERTER air conditioner can only operate at a constant speed which is too powerful to maintain the set temperature. Thus, it switches the compressor on and off repeatedly. This results in wider temperature fluctuations leading to wasteful consumption of energy.
Time
Legend:
SUNLIGHT DETECTION
Output Power
Temperature
Remark: Energy is wasted by switching the compressor ON and OFF to maintain the set temperature.
INVERTER
Output power
Room Little temperature temperature fluctuations
Set temperature
ON Time
HUMAN ACTIVITY DETECTION Legend:
ECONAVI SAVES YOU ENERGY BECAUSE IT SENSES:
Output Power
Temperature
The Panasonic INVERTER air conditioner varies the rotation speed of the compressor, providing a precise method of maintaining the set temperature. Thus, Panasonic INVERTER air conditioners give you exceptional energy saving performance while ensuring you stay comfortable at all times.
Remark: Saves energy by varying the rotation speed of the compressor to maintain the set temperature.
CONSTANT COMFORT
Whether it’s a sunny day or at night.
Where you are.
Precise temperature control with a wide power output range enables an INVERTER air conditioner to meet different room occupancy levels – thus ensuring constant comfort. MAXIMUM POWER
MEDIUM POWER
MINIMUM POWER
Compressor rotation speed: HIGH
Normal condition
Compressor rotation speed: SLOW
SUNLIGHT DETECTION
AREA SEARCH
When you leave the room. TEMPERATURE WAVE
ABSENCE DETECTION
When you are less active.
Adapts rhythmic temperature control after detecting low activity level. When required, the unit operates at full power.
Power: 4.20kW
When not required, the unit operates at low power to save energy.
Power: 3.67kW
Power: 0.92kW
ACTIVITY DETECTION Graph shows the 1.5HP PREMIUM Inverter model’s wide power output range during cooling.
* Applicable to PREMIUM Inverter only.
28 - 29
PURIFIES AIR IN YOUR HOME DOWN TO THE SMALLEST DETAIL
- AIR PURIFICATION
nanoe-G releases 3 trillion of fine particles to clean the air in your home environment for fresher and cleaner living.
1
REMOVAL OF AIRBORNE PARTICLES
nanoe-G can effectively remove up to 99% of PM2.5*1 and airborne particles*2 such as bacteria, viruses and mould. *1
1 *š *²
PM2.5, Bacteria, Viruses & Mould Removal
AIRBORNE
2 Remark: * 3 trillion is the simulated number of nanoe-G fine particles under the mentioned conditions. Actual measured nanoe-G fine particles at the centre 2 of the room (13m ):100k/cc calculated number of nanoe-G fine particles in the entire room assuming they are evenly distributed.
Removal of airborne particles, even those smaller than 2.5 micrometers in size (PM2.5). Airborne particles:
PM2.5
Bacteria
Viruses
DEACTIVATION OF ADHESIVE MICRO-ORGANISMS AND DEODORISATION OF ADHESIVE ODOURS
nanoe-G particles are able to deactivate up to 99%*3 of bacteria, viruses and inhibit mould growth that settles on surfaces around you. The odours adhered on the curtains and sofa are deodorised.
Mould
*3
Natural Ion Wind spreads nanoe-G fine particles that are released from the nanoe-G generator.
IN-FILTER DEACTIVATION
3 *4
nanoe-G catches airborne particles
Bacteria & Viruses Deactivation
Deactivates bacteria and viruses trapped in the filter.
2 Mechanism
*3
Odour Particle
Bacteria & Viruses Deactivation
nanoe-G Strike Odour Particles
&*2 Please refer to page 30 - 32
Decompose and Remove Odour
ADHESIVE Deactivates adhesive micro-organisms and deodorises adhesive odours.
3 trillion* nanoe-G fine particles released from the generator.
3
Please refer to page 33
IN-FILTER DEACTIVATION With In-Filter Deactivation, nanoe-G deactivates 99%*4 of bacteria and viruses trapped inside the filter. *4
Please refer to page 34 & 35
nanoe-G
30 - 31
i A U TO - X
nano e-G
T E C H N I C A L E X P L A N AT I O N
SOURCES OF PM2.5
W H AT I S PM2.5?
PM2.5 can be found suspended in the air, including dust, dirt, smoke and liquid droplets. These fine particles come from man-made sources such as the combustion of fossil fuels, open burning and industrial processes as well as natural ones, which include sea sprays and dust carried by strong winds.
"Particulate matter," also known as PM is made up of a number of components including extremely small particles and liquid droplets. Sized at less than 2.5 micrometers (PM2.5), these particles are said to pose health problems as they can easily enter our lungs. PM2.5 REMOVAL EFFICIENCY BASED ON TIME SERIAL MEASUREMENT OF PM2.5 CONCENTRATION
POLLEN
BACTERIA / MOULD
FINE PARTICLES
PM2.5
DIAMETER >10μm
<2.5μm
<10μm
PM2.5 Concentration (mg/ m3)
22 | 23
Legend:
2.0
Air conditioner with nanoe-G
1.8 1.6 1.4
80 min
1.2 1.0
202 min
90% removal
0.8
99% removal
0.6 0.4 0.2 0.0 0
30
60
90
120
150
180
210
240
270
300 Time Elapsed (min.)
PARTICLE SIZE COMPARISON AIRBORNE PARTICLE SIZE COMPARISON
REMOVES
Size (μm) Large
POLLEN 10µm-100µm
10µm
99
%*1 PM2.5
REMOVES
*2 % 99
BACTERIA VIRUSES and MOULD
BACTERIA 1µm-10µm 2.5µm PM2.5 is found in
VIRUS 0.001µm-0.1µm
∙ ∙ ∙ ∙
Industrial Smoke Exhaust Gas Haze Cigarette Smoke
Small
*1 PM2.5 Removal was certified by FCG Research Institute, Inc
*² Airborne Removal was certified by Kitasato Research Center for Environmental Science
• Test Report no. : 25034 PM2.5 : Cigarette Smoke (as PM2.5)
• KRCES-Bio. Test Report no. : 23_0182 Bacteria : Staphylococcus aureus (NBRC 12732)
Effectiveness is measured on 0.3μm-2.5μm. (Specific size only) This removal effect is not proven for all the airborne toxic substances.
• KRCES-Env. Test Report no. : 22_0008 Virus : Escherichia coli phage (øX-174 ATCC 13706-B1) : Influenza (H1N1) 2009 Virus
All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
• KRCES-Env. Test Report no. : 23_0140 Mould : Penicillium pinophilum (NBRC 6345) All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
22 | 23
32 - 33
i A U TO - X
THE EFFECTIVENESS OF PM2.5
nano e-G
T E C H N I C A L E X P L A N AT I O N
ADHESIVE ODOUR DEODORISATION: THE ODOUR ADHERED ON THE CURTAINS AND SOFA
AIRBORNE DATA ON REMOVAL OF AIRBORNE BACTERIA WAS PRESENTED BY HARVARD SCHOOL OF PUBLIC HEALTH RESEARCHERS AT NANO-SYMPOSIUM AT KYOTO UNIVERSITY, 2012
nanoe-G
0.1 nanoe-G on nanoe-G off 0.01
1 log10 reduction Projection
Experimental data 0
20
40
60
80
100
120
140
160
180
time (min)
A study of the removal effect of airborne bacteria by using an air-conditioner incorporating nanoe-G was carried out in a large space, and the results were presented at Nano-Symposium jointly held in September 2012 by Harvard University and Kyoto University. Test methods: Bacteria removal method: Release of nanoe-G ions. Target: Airborne bacteria, Test results: It is estimated that after three hours of operation the nanoe-G will achieve 2.7 log10 reductions, ~ 1 log10 reduction more, as compared to without nanoe-G.
Adhesive smell of tobacco smoke 20m³ Six-level odour intensity indication method 13-1204
Odour Intensity
Degree of Smell
0 1 2 3 4 5
No odour Barely able to detect (detection threshold) Able to recognise a smell, but weak (recognition threshold) Easily perceptible Strong Very Strong
Odour Intensity
Test Subject: Test Chamber: Measurement Method: Test report No.:
“Performance evaluation of a novel ionizer for air purification applications”. Dr. S. Rudnick et al. Harvard School of Public Health, Environmental Health Nanoscience Lab.
1
C/Co (Normalized spore concentration)
4
The effect after 100 minutes in a 40 m³ test space [about the size of a 10 tatami mat room], not the effect in a space where actually used.
In a large space of 40 m³ Removal effect has been evaluated.
0.001
5
Decrease in odour intensity by one level after 2 hours of operation.
4.17 3.25
3
1 Level Down 2.25
2 Natural Decay
AC with
nanoe-G
1 0
Initial
After 2 hours
ADHESIVE AIRBORNE TARGET SUBSTANCE
SUBSTANCE NAME
PM2.5
Cigarette Smoke (as PM2.5)
Bacteria
Staphylococcus aureus (NBRC 12732)
EFFECTIVENESS
TESTING INSTITUTE
TEST REPORT NO
Test Report No. 25034
The AC with nanoe-G was operated in a test room (23m³) and the concentration of PM2.5 was measured by PM2.5 Digital Dust Indicator.
99% removal from the air after 202 minutes of operation.
99%
Kitasato Research Center for Environmental Science
KRCES-Bio. Test Report No. 23_0182
The AC with nanoe-G was operated in a test room (25m³) and aerosol was collected and bacterial count was calculated.
99% removal from the air after 150 minutes of operation.
99%
Kitasato Research Center for Environmental Science
KRCES-Env. Test Report No. 22_0008
The AC with nanoe-G was operated in a test room (25m³) and airborne phages were collected and phage count of the collected air was calculated.
99% removal from the air after 120 minutes of operation.
99%
Kitasato Research Center for Environmental Science
KRCES-Env. Test Report No. 22_0008
nanoe-G was operated in a test chamber (200 Litre) and the phages were collected and phage count of the collected air was calculated.
99% removal from the air after 5 minutes of operation.
nanoe-G was operated in a test chamber (200 Litre) and the influenza viruses were collected and the virus titers were calculated by the Reed and Muench method.
99% removal from the air after 5 minutes of operation.
99%
Virus
Mould
Penicillium pinophilum (NBRC 6345)
RESULT
FCG Research Institute, Inc
Escherichia coli phage (øX-174 ATCC 13706-B1)
Influenza (H1N1) 2009 virus
METHOD
99%
99%
Kitasato Research Center for Environmental Science
Kitasato Research Center for Environmental Science
KRCES-Env. Test Report No. 22_0008
KRCES-Bio. Test Report No. 23_0140
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
SUBSTANCE NAME
Bacteria
Staphylococcus aureus (NBRC 12732)
Virus
Mould
TESTING INSTITUTE
TEST REPORT NO
99%
Japan Food Research Laboratories
Bacteriophage (Phi X 174 NBRC 103405)
99%
Cladosporium cladosporioides (NBRC 6348)
Inhibit Mould Growth
Smell of tabacco smoke
Odour
EFFECTIVENESS
Decrease by one level
99% removal from the air after 90 minutes of operation.
METHOD
RESULT
Test Report No. 11047933001-02
The AC with nanoe-G was operated in a test space (10m³) and viable cells were counted by pour plate method.
99% inactivation after 24 hour operation of nanoe-G. (compared to the original condition/ ventilation mode)
Japan Food Research Laboratories
Test Report No. 11073649001-02
nanoe-G was operated in a test box (90 Litre) and phage infectivity titer was determined by plaque technique.
99% inactivation after 120 minutes operation of nanoe-G. (compared to non-operation)
Japan Food Research Laboratories
Test Report No. 11047937001-02
nanoe-G was operated in a test box (1m³) and colonies on the plate were counted.
The growth of the subject was inhibited. (>85% after 7 days)
Test Report No. 13-1204
The AC with nanoe-G was operated in a test room (20m³) and the deodorisation effect on a piece of cloth impregnated with odour components of cigarette smoke was evaluated using six-level odour intensity indication method.
Decrease in odour intensity by one level after 120 minutes of operation.
OMI ODOR-AIR SERVICE Co.Ltd.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
ADHESIVE
In view of health hazard associated with spatial distribution of Influenza (H1N1) 2009 virus, nanoe-G removal effectiveness cannot be tested in large test room (25m³). When tested in 200 Litre chamber, nanoe-G was able to decrease Influenza (H1N1) 2009 virus (99%) when it was operated for 5 minutes. Additionally when tested in larger test room (25m³), nanoe-G can remove 99.5% of Coli phage virus when operated for 120 minutes. It was validated that evaluation on the influenza virus could be speculated from the results on the phage according to the test results in a 200 Litre test chamber. It appeared that the air-conditioners in a larger test room (25m³) would be able to remove the influenza virus as effectively as the phage. The AC with nanoe-G was operated in a test room (25m³) and aerosol was collected and fungal spores count was calculated.
TARGET SUBSTANCE
ADHESIVE ODOURS
DEACTIVATES
99
%*3 BACTERIA and VIRUSES
DEODORISES ADHESIVE ODOUR (TOBACCO SMELL)
INHIBITS MOULD GROWTH
*³ Adhesive Deactivation was certified by Japan Food Research Laboratories
Adhesive odour deodorisation was certified by OMI ODOR-AIR SERVICE Co. Ltd.
• Test Report number : 11047933001-02 Bacteria : Staphylococcus aureus (NBRC 12732) • Test Report number : 11073649001-02 Virus : Bacteriophage (Phi X 174 NBRC 103405) • Test Report number : 11047937001-02 Mould : Cladosporium cladosporioides (NBRC 6348)
• Test Report No. 13-1204
All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
22 | 23
i A U TO - X
34 - 35
nano e-G
TEST REPORT NO
METHOD
RESULT
Test Report No. 12037932001
The test piece impregnated with Staphylococcus aureus was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, viable cells were counted. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.
99% of deactivation after 2-hour nanoe-G operation.
Test Report No. 12014705001
The test piece impregnated with Escherichia coli phage was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, phage infectivity titer was determined. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.
T E C H N I C A L E X P L A N AT I O N
IN-FILTER DEACTIVATION
HOW DOES IN-FILTER DEACTIVATION WORK?
TARGET SUBSTANCE
Bacteria
SUBSTANCE NAME
Staphylococcus aureus (NBRC 12732)
Escherichia coli phage (øX-174 ATCC 13706-B1)
EFFECTIVENESS
99%
99%
TESTING INSTITUTE
Japan Food Research Laboratories
Japan Food Research Laboratories
99% of deactivation after 2-hour nanoe-G operation.
Virus
1. POWER “OFF”
2. FAN OPERATION
The air-conditioner first has to be turned off.
The fan operation will run automatically for 30 minutes with the flaps slightly open to ensure the internal components are dry and free from condensation.
Remark: Main power must be switched on for the entire duration.
Remark: The 30-minute fan operation is only applicable when the unit has been operated in COOL /DRY mode.
Fan Operation : On Flap : Flaps slightly open nanoe-G LED : On
Influenza (H1N1) 2009 Virus
Average 90% on filter (The percentage varies from 78.9% to 96.1% depending on its location)
99 Natural Ion Wind spreads nanoe-G particles that are released from the nanoe-G generator.
nanoe-G deactivates bacteria and viruses that are trapped in the filter within 2 hours.
Fan Operation : Off Flap : Closed nanoe-G LED : On
Remark: Depending on the Air Conditioner’s accumulated operation time, nanoe-G In-Filter Deactivation may be activated only once a day.
Average 90% deactivation after 2-hour nanoe-G operation. (The percentage varies from 78.9% to 96.1%, depending on its location on filter)
IN-FILTER DEACTIVATION
%*4
4. DEACTIVATION EFFECT
KRCES-Virus Test Report No. 24_0013
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
DEACTIVATES
3. nanoe-G OPERATION
Kitasato Research Center for Environmental Science
The test piece impregnated with Influenza (H1N1) 2009 Virus was placed on the filter of the Air Conditioner indoor unit, and then nanoe-G was operated. After the test piece was collected, virus infectivity titer was determined. * test substance was placed on the 4 locations of the filter; upper/lower right and upper/lower left.
BACTERIA and VIRUSES
INHIBITS MOULD GROWTH
*⁴ In-Filter Deactivation was certified by Japan Food Research Laboratories • Test Report number : 12037932001 Bacteria : Staphylococcus aureus (NBRC 12732) • Test Report number : 12014705001 Virus : Escherichia coli phage (φΧ-174 ATCC 13706-B1) All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
DEACTIVATES AVERAGE
9O%
INFLUENZA (H1N1) 2009 VIRUS
In-Filter Deactivation was certified by Kitasato Research Center for Environmental Science • Test Report number : KRCES-Virus Test Report No. 24_0013 Virus : Influenza (H1N1) 2009 Virus All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
36 - 37
i A U TO T E C H N I C A L E X P L A N AT I O N
SINE WAVE DRIVE iAUTO utilises high efficient Sine Wave DC motor to realise both powerful cooling and energy saving. SINE WAVE COMPARISONS
- COOLING COMFORT Equipped with the Automatic Intelligence to switch between fan speeds, iAUTO gives you up to 15% faster cooling at start up with consistent airflow and automatic fan speed.
Sine Wave (blue) curves smoothly compared to conventional rectangle (grey)
Sine Wave drive produces smooth wave curves.This reduces power loss or energy waste. Conventional rectangle drive produces distortions which results in power efficiency loss.
ADVANTAGES OF SINE WAVE
Reduced current distortion enables fan motor to start faster, run cooler and perform more efficiently even while running at super high fan speed to help reduce power consumption.
MOTOR EFFICIENCY DATA (EX. INDOOR UNIT) 80 75 Efficiency (%)
1. EFFICIENCY UP EVEN AT HIGH ROTATIONAL SPEED PER MINUTE (RPM)
70 65 60 300
2. STABLE OPERATION
500
700
900
1100
1300
1500
Speed (r/min)
Sine Wave regulates power voltage that is identical to power supplied, ensuring consistent performance and stable operation.
Legend:
Sine Wave
Conventional rectangle
3. LOW VIBRATION Motor loads runs smoother with low vibrations resulting in quieter operation. QUALITY CONTROL THROUGH SIMULATED LABORATORY TEST
TRUE COMFORT IS JUST A TOUCH AWAY 1. FAST COOLING AT START UP 2014 model iAUTO mode
29ºC
2013 cool mode with High Fan
At start up, iAUTO will run at super high fan speed to cool the room faster, 15% faster for cooler comfort.
Quick
2. MAINTAIN COOLING COMFORT
25ºC
Super High High Medium
Fan Speed
Room Temperature
35ºC
Time
Once the room cools down, iAUTO provides constant cool airflow to maintain a comfortable level of relative humidity, to stay cool and comfortable all day long.
Panasonic carried out testing at our own Environmental Testing Room which simulates a standard living room condition. This makes it possible to ensure air conditioner operates at optimum performance level under varying conditions. Testing is done in a large space of 16.6m² to simulate size of actual living room. Indoor temperature is measured using 150 sensors to get the average room temperature. This ensures accuracy of indoor temperature data.
16.6m²
* Comparison of 1.5HP Deluxe non-Inverter model with iAUTO mode and cooling mode iAUTO Mode iAUTO Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature: 25˚C with Fan Speed: Auto Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight
3. AUTOMATIC FAN SPEED iAUTO automatically switches fan speed to high and super high fan speed depending on the temperature difference between the room and the set temperature.
150 SENSORS
FASTER COOLING
Cooling Mode with High Fan COOL Mode, Outside Temperature: 35˚C /24˚C Remote setting temperature : 25˚C with Fan Speed High Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight The cooling speed was calculated by measuring the time to reach the setting temperature. At Panasonic Amenity Room (size: 16.6m²) The effect differs according to conditions in installation and usage.
* Applicable to Standard Inverter, Standard non-Inverter & Semi Deluxe non-Inverter.
38 - 39 WALL-MOUNTED :
P R O D U CT L I N E - U P
Single-Split Type
ELITE
BACKLIT SKY CONTROLLER Enjoy innovative design at your fingertips with the new stylish and sleek Backlit Sky Controller. With fast access to key operations and a smooth gliding cover revealing more options, controlling your settings has become simple and intuitive.
CS-VS10SKH | CS-VS13SKH | CS-VS18SKH
Wireless
With a width of 58.9mm and a length of 164.7mm, the Sky Controller fits comfortably into your hand.
Wired (Optional)
(CS-VS10SKH)
SPECIFICATIONS
COOLING MODELS
MODEL
Cooling Capacity EER
Electrical Data
(50Hz)
(min-max)
kW
(min-max)
Btu/h
(min-max)
Btu/hW
Noise Level
2.85 (0.84-3.28)
3.66 (0.92-4.20)
5.20 (1.10-5.80)
9,720 (2,860-11,200)
12,500 (3,140-14,300)
17,700 (3,750-19,800)
13.5 (12.71-12.44)
13.16 (12.08-12.12)
12.21 (12.93-11.72)
V 3.5 - 3.2
4.6 - 4.2
7.0 - 6.4
Power Input (min-max)
W
720 (225-900)
950 (260-1,180)
1,450 (290-1,690)
1.7
2.1
2.9
3.6
4.4
6.1
Indoor
m3/min (ft3/min)
(Pt/h)
10.1 (355)
12.0 (425)
13.4 (475)
Outdoor
m3/min (ft3/min)
21.6 (760) - 22.9 (810)
29.0 (1,020) - 29.6 (1,040)
34.9 (1,230) - 34.9 (1,230)
Indoor (H / L / Q-Lo)
dB (A)
36/25/18 - 36/25/18
41/27/19 - 41/27/19
46/36/31 - 46/36/31
Outdoor (H / L)
dB (A)
(47) - (48)
(48) - (49)
(49) - (50)
Width
mm
318 (511)
318 (542)
318 (619)
inch
12-17/32 (20-1/8)
12-17/32 (21-11/32)
12-17/32 (24-3/8)
mm
950 (650)
950 (780)
950 (824)
inch
37-13/32 (25-19/32)
37-13/32 (30-23/32)
37-13/32 (32-15/32)
mm
280 (230)
280 (289)
280 (299)
inch
11-1/32 (9-1/16)
11-1/32 (11-13/32)
11-1/32 (11-25/32)
Indoor
kg (lb)
Outdoor
kg (lb)
Refrigerant Pipe Diameter Gas Side
Backlit LED screen lets you view operations status in the dark.
2
Power Button.
3
iCOMFORT lets you come home to fast cooling. Then enjoy continuous comfort with RADIANT COOLING which avoids direct cooling.
DUST SENSOR
RADIANT COOLING
4
Press up or down to set the temperature.
5
Toggles between RADIANT COOLING (SHOWER) and Fast Cooling (DIRECT).
220 - 240
L/h
Liquid Side
Pipe Extension
[CU-VS18SKH]
A
Depth
Net Weight
CS-VS18SKH
[CU-VS13SKH]
Current
Height
Dimensions
CS-VS13SKH
[CU-VS10SKH]
Voltage
Moisture Removal
Air Circulation
CS-VS10SKH
1
(Random)
CS-VS10SKH/ CS-VS13SKH
CS-VS18SKH
(Optional)
6
Activates the nanoe-G even when the air conditioner is switched off.
7
Set the airflow.
8
Adjusts the fan speed.
9
Toggles between COOL and DRY setting mode.
10 Delays off timer with temperature
control for better sleep.
13 (29) 21 (46)
29 (64)
mm
6.35
inch
1/4
33 (73)
24-hour Dual ON & OFF Timer.
mm
9.52
12.70
inch
3/8
1/2
12 Set the actual time [hour and
minute].
Chargeless Pipe Length
m
7.5
10
Maximum Pipe Length
m
15
30
Maximum Elevation Length
m
5
Additional Refrigerant Gas**
g/m
20 15 Indoor
Power Supply
Caution For CS-VS10/VS13/VS18SKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. * When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR CU-VS10SKH
CU-VS13SKH
11 Set the 24-hour ON & OFF Timer or
CU-VS18SKH
1
2 3 4
5
6
7
8 10
9
11
12
40 - 41 WALL-MOUNTED : PREMIUM
P R O D U CT L I N E - U P
Single-Split Type
EASY-TO-USE REMOTE CONTROLLER
Wireless
CS-S10RKH | CS-S13RKH
CS-S18RKH | CS-S24RKH | CS-S28RKH
Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.
Wired (Optional)
Wireless
(
Cooling Capacity
(min-max) (min-max)
CS-S28RKH
[CS-S10RKH]
[CS-S13RKH]
[CS-S18RKH]
[CS-S24RKH]
[CS-S28RKH]
9,720 (2,860-11,200)
12,500 (3,140-14,300)
18,100 (3,750-20,500)
21,300 (3,820-24,200)
24,200 (3,920-29,000)
2.85 (0.84-3.28)
3.67 (0.92-4.20)
5.30 (1.10-6.00)
6.25 (1.12-7.10)
7.10 (1.15-8.50)
13.3
12.4
12.6
11.3
11.9
8.8 - 8.2
9.6 - 9.0
3.6 - 3.3
5.1 - 4.6
7.0 - 6.4
W
730 (225-920)
1,010 (260-1,200)
1,440 (290-1,700)
1,880 (320-2,200)
2,030 (350-2,700)
L/h
1.7
2.1
2.9
3.5
4.1
Pt/h
3.6
4.4
6.1
7.4
8.7
Indoor
m³/min.
10.1
10.9
17.7
18.1
18.4
Outdoor
ft³/min.
355
385
625
640
650
Indoor (H/L/Q-Lo)
(dB-A)
36/26/23 - 36/26/23
38/28/25 - 38/28/25
44/32/29 - 44/32/29
45/34/31 - 45/34/31
47/37/34 -
Outdoor (H/L)
(dB-A)
Width
Net Weight
Liquid Side Refrigerant Pipe Diameter Gas Side
(46) - (47)
(47) - (48)
(49) - (50)
(51) - (52)
(52) - (53)
mm
296 (511)
296 (542)
296 (619)
296 (695)
296 (795)
inch
11-21/32 (20-1/8)
11-21/32 (21-11/32)
11-21/32 (24-3/8)
11-21/32 (27-3/8)
11-21/32 (31-5/16)
mm
870 (650)
870 (780)
1,070 (824)
1,070 (875)
inch
34-9/32 (25-19/32)
34-9/32 (30-23/32)
42-5/32 (32-15/32)
42-5/32 (34-15/32)
mm
236 (230)
236 (289)
241 (299)
241 (320)
inch
9-15/16 (9-1/16)
9-15/16 (11-13/32)
9-1/2 (11-25/32)
9-1/2 (12-5/8)
3
ECONAVI monitors sunlight intensity, human movement, activity levels and human absence to detect and reduce energy waste.
4
Activates the nanoe-G function even when the air conditioner is switched off.
5
Press up or down to set the temperature.
6
1
3
2 5
6
Toggles between iAUTO-X, COOL and DRY setting mode.
10
9
(Random)
CS-S10RKH/ CS-S13RKH
(Optional)
CS-S18RKH/ CS-S24RKH
CS-S28RKH
7 Auto comfort mode detects high activity levels and switches to comfort operation for maximum comfort.
11 12
8
Set the airflow.
9
Adjusts the fan speed.
10 Quiet function allows you to sleep
comfortably at night. Wireless Applicable to PREMIUM Inverter
11 Set the 24-hour ON & OFF Timer or
12 Set the actual time (hour and
minute).
9 (20)
9 (26)
12 (34)
12 (46)
12 (57)
lb
20 (44)
20 (57)
26 (75)
26 (101)
26 (126)
DUAL TIMER
ø 6.35
mm
1/4
inch ø 9.52
ø 12.70
ø 15.88
3/8
1/2
5/8
inch
DUAL TIMER FOR 2 ON AND OFF TIMES PER DAY
10
Chargeless Pipe Length
m
7.5
Maximum Pipe Length
m
15
20
30
Maximum Elevation Length
m
5
15
20
Additional Refrigerant Gas**
g/m
20
15
Power Supply
For convenience, the dual timer repeats everyday until you cancel it.
30 Outdoor
Indoor
Select ON or OFF Timer
Caution For CS-S10/S13/S18/S24/S28RKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness. * When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
1
2
1
Cancel
OUTDOOR CU-S10RKH
CU-S13RKH
CU-S18RKH
CU-S24RKH
4 8
7
24-hour Dual ON & OFF Timer.
kg
mm
Come home to fast cooling. Then enjoy continuous comfort with Shower Cooling which avoids direct cooling.
C
220 - 240
A
Depth
Pipe Extension
CS-S24RKH
Running Current
Height
Dimensions
CS-S18RKH
V
Moisture Removal
Noise Level
CS-S13RKH
Voltage
Power Input
Air Circulation
kW
CS-S10RKH
Btu/hW
EER
Electrical Data
Btu/h
2
): Outdoor Unit
COOLING MODELS (50Hz)
LCD display for an easy overview of the operation status.
Wired (Optional)
SPECIFICATIONS MODEL
1
CU-S28RKH
Set the time. TIMER
2
Cancel
42 - 43
P R O D U CT L I N E - U P
WALL-MOUNTED : DELUXE NON-INVERTER Single-Split Type
EASY-TO-USE REMOTE CONTROLLER Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.
Wireless
CS-C9RKH | CS-C12RKH
CS-C18RKH | CS-C24RKH | CS-C28RKH
(
Cooling Capacity EER
Electrical Data
[CS-C12RKH]
[CS-C18RKH]
[CS-C24RKH]
[CS-C28RKH]
18,400 - 18,400
24,000 - 24,000
26,900 - 27,300
kW
2.65 - 2.70
3.52 - 3.57
5.40 - 5.40
7.03 - 7.03
7.90 - 8.00
Btu/hW
11.3 - 11.0
10.8 - 10.6
10.5 - 10.0
10.2 - 9.7
9.9 - 9.9
11.0 - 11.1
12.6 - 12.0
5.2 - 5.2
8.5 - 8.4
W
800 - 835
1,110 - 1,150
1,750 - 1,850
2,350 - 2,470
2,720 - 2,760
L/h
1.6
2.1
2.9
4.0
4.7
Pt/h
3.4
4.4
6.1
8.5
9.9
Indoor
m³/min.
9.8
10.8
16.4
18.2
20.2
Outdoor
ft³/min.
346
381
579
642
713
Indoor (H/L/Q-Lo)
(dB-A)
36/26 - 36/26
39/29 - 29/29
43/37 - 43/37
46/40 - 46/40
49/44 - 49/44
Outdoor (H/L)
(dB-A)
(46) - (47)
(48) - (49)
Net Weight
Liquid Side Refrigerant Pipe Diameter Gas Side
(53) - (54)
(54) - (55)
(55) - (56)
mm
296 (511)
296 (542)
296 (695)
296 (750)
inch
11-21/32 (20-1/8)
11-21/32 (21-11/32)
11-21/32 (27-3/8)
11-21/32 (29-17/32)
mm
870 (650)
inch
34-9/32 (25-19/32)
1,070 (780)
1,070 (875)
42-5/32 (30-23/32)
42-5/32 (34-15/32)
236 (230)
241 (289)
241 (320)
241 (345)
inch
9-5/16 (9-1/16)
9-1/2 (11-13/32)
9-1/2 (12-5/8)
9-1/2 (13-19/32)
kg
9 (21)
9 (25)
12 (34)
12 (52)
12 (62)
lb
20 (46)
20 (55)
26 (75)
26 (115)
26 (137)
mm
ø 6.35
inch
1/4
inch
Chargeless Pipe Length
m
Maximum Pipe Length
m
Maximum Elevation Length
m
Additional Refrigerant Gas**
g/m
Power Supply
ECONAVI monitors sunlight intensity, human movement, activity levels and human absence to detect and reduce energy waste.
ø 12.70
ø 15.88
3/8
1/2
5/8
30
25
20 Indoor
(Random)
CS-C12RKH
CS-C18RKH/ CS-C24RKH
CS-C28RKH
6
10
CS-C9RKH
8
Set the airflow.
9
Adjusts the fan speed.
11 12
comfortably at night. Wireless Applicable to Deluxe non-Inverter
11 Set the 24-hour ON & OFF Timer.
minute).
2
3
ON
OFF
SET
2
33 CANCEL CAN CEL
Select ON or OFF Timer
Example: OFF at 22:00 OFF
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
Set the time. 2
OUTDOOR CU-C9RKH CU-C12RKH
CU-C18RKH
CU-C24RKH
CU-C28RKH
9
10 Quiet function allows you to sleep
1
Outdoor
4 8
7 Auto comfort mode detects high activity levels and switches to comfort operation for maximum comfort.
30 Indoor
Indoor
5
7
Toggles between iAUTO, COOL and DRY setting mode.
1
20
10
Press up or down to set the temperature.
TIMER
5
Indoor
5
3
2
To turn the unit ON or OFF at a preset time.
7.5 15
Activates the nanoe-G function even when the air conditioner is switched off.
TO SET THE TIMER
ø 9.52
10
4
1
12 Set the actual time (hour and
mm
mm
3
6
220 - 240 3.8 - 3.7
Width
Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.
CS-C28RKH
12,000 - 12,200
A
Depth
Pipe Extension
CS-C24RKH
9,040 - 9,210
Running Current
Height
Dimensions
CS-C18RKH
V
Moisture Removal
Noise Level
CS-C12RKH
Voltage
Power Input
Air Circulation
CS-C9RKH [CS-C9RKH]
Btu/h
2
): Outdoor Unit
COOLING MODELS (50Hz)
LCD display for an easy overview of the operation status.
Wireless
SPECIFICATIONS MODEL
1
Confirm. TIMER
SET
44 - 45
P R O D U CT L I N E - U P
WALL-MOUNTED : STANDARD NON-INVERTER Single-Split Type
EASY-TO-USE REMOTE CONTROLLER
CS-PC9QKH | CS-PC12QKH
Panasonic’s wireless remote controller features a large Liquid Crystal Display (LCD) panel which makes it even more user-friendly. So you can sit back and enjoy easy operation and long-lasting comfort from your Panasonic Air Conditioner.
Wireless
CS-PC18QKH | CS-PC24QKH | CS-PC28QKH
Cooling Capacity EER
Electrical Data
Air Circulation
Noise Level
CS-PC12QKH
CS-PC18QKH
CS-PC24QKH
CS-PC28QKH
(CU-PC9QKH)
(CU-PC12QKH)
(CU-PC18QKH)
(CU-PC24QKH)
(CU-PC28QKH)
Btu/h
9,040 - 9,210
11,900 - 12,100
18,000 - 18,100
23,600 - 24,000
26,900 - 27,300
kW
2.65 - 2.70
3.49 - 3.54
5.28 - 5.30
6.93 - 7.03
7.90 - 8.00
Btu/hW
10.7 - 10.4
10.2 - 10.0
9.4 - 9.1
9.2 - 8.9
9.0 - 9.0
4.4 - 4.3
5.5 - 5.6
8.9 - 9.0
12.2 - 12.1
14.0 - 13.1
Power Input
W
845 - 885
1,170 - 1,210
1,920 - 1,980
2,570 - 2,700
2,990 - 3,040 4.7
L/h
1.6
2.1
2.9
4.0
Pt/h
3.4
4.4
6.1
8.5
9.9
Indoor
m³/min.
8.9
11.1
16.4
18.7
20.2
Outdoor
m³/min.
324
392
579
660
713
Indoor (H/L)
(dB-A)
37/26 - 37/26
40/29 - 40/29
43/39 - 43/39
47/42 - 47/42
50/46 - 50/46
Outdoor (H/L)
(dB-A)
(50)
Width
Net Weight
Liquid Side Refrigerant Pipe Diameter Gas Side
(53)
(56)
(60)
(55)
mm
290 (511)
290 (542)
290 (695)
290 (750)
inch
11-7/16 (20-1/8)
11-7/16 (21-11/32)
11-7/16 (27-3/8)
mm
850 (650)
1,070 (780)
inch
33-15/32 (25-19/32)
42-5/32 (30-23/32)
mm
199 (230)
240 (289)
240 (320)
235 (345)
inch
7-27/32 (9-1/16)
9-15/32 (11-13/32)
9-15/32 (12-5/8)
9-9/32 (13-19/32)
8 (22)
8 (24)
12 (34)
12 (52)
12 (63)
18 (53)
26 (75)
26 (115)
26 (139)
mm
ø 6.35
inch
1/4
mm
ø 9.52
ø 12.70
inch
3/8
1/2
m
Maximum Elevation Length
m
Additional Refrigerant Gas*
g/m
4
Set the airflow.
5
Press up or down to set the temperature.
1
Optional
6
Set the 24-hour ON & OFF Timer.
2 5
10
CS-PC9QKH
CS-PC12QKH
4
6
CS-PC18QKH/ CS-PC24QKH
CS-PC28QKH
Wireless Applicable to Standard non-Inverter
TO SET THE TIMER To turn the unit ON or OFF at a preset time. 1
2
ON
1 OFF
ø 15.88
3 SET
2
33 CANCEL CAN CEL
5/8 Select ON or OFF Timer
15
Example: OFF at 22:00
30
25
5
OFF
20
10
20 Indoor
30
Indoor
Indoor
Set the time. Outdoor
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
2
Confirm. TIMER
OUTDOOR CU-PC9QKH CU-PC12QKH
3
Random
TIMER
7.5
Indoor
Power Supply
Adjusts the fan speed.
42-5/32 (34-15/32)
18 (49)
Maximum Pipe Length
3
11-7/16 (29-17/32)
lb
m
Toggles between iAUTO, COOL, and DRY setting mode.
1,070 (875)
kg
Chargeless Pipe Length
2
220 - 240
V A
Depth
Pipe Extension
CS-PC9QKH
Running Current
Height
Dimensions
(50Hz)
Voltage
Moisture Removal
Automatic intelligence switches fan speed for faster cooling.
Wireless
SPECIFICATIONS MODEL
1
CU-PC18QKH
CU-PC24QKH
CU-PC28QKH
SET
46 - 47
F E AT U R E S C O M PA R I S O N Split Type
F E AT U R E S E X P L A N AT I O N
ELITE Inverter
PREMIUM Inverter
DELUXE Non-Inverter
STANDARD Non-Inverter Wall-Mounted
Cooling Models
CS-VS10SKH CS-VS13SKH CS-VS18SKH
CS-S10RKH CS-S13RKH
CS-S18RKH CS-S24RKH CS-S28RKH
CS-C9RKH CS-C12RKH
CS-C18RKH CS-C24RKH CS-C28RKH
CS-PC9QKH CS-PC12QKH
CS-PC18QKH CS-PC24QKH CS-PC28QKH
RADIANT COOLING
TEMPERATURE WAVE
C
Rhythmic temperature-controlled pattern to save energy without sacrificing comfort.
Come home to fast cooling. Then enjoy continuous comfort with Shower Cooling which avoids direct cooling.
SLEEP MODE
Delays off timer with temperature control for better sleep.
Detects and reduces waste for more energy savings.
SLEEP
AUTOCOMFORT
AIRFLOW DIRECTION CONTROL (UP & DOWN)
PERSONAL AIRFLOW CREATION
iCOMFORT
Vertical and horizontal airflow patterns can be combined as desired to achieve optimum comfort, with operation possible by remote even from a distance.
Temperature Wave AUTOCOMFORT
Varies the rotation speed of the compressor for higher energy savings.
SOFT DRY OPERATION MODE
Detects high activity levels and adjusts cooling power to improve comfort.
* Fast Cooling. Refer to Page 8-9
INVERTER CONTROL
QUIET MODE
Automatic Intelligence switches fan speed for faster cooling with just one touch of a button.
ECONAVI
SLEEP
Cools the ceiling and walls first, providing continuous cooling comfort without direct airflow.
ECONAVI
iAUTO-X
RADIANT COOLING
Starts with cooling to dehumidify, then provides continuous breeze at a low frequency to keep a room dry without much change to the temperature.
Radiant Cooling
iAUTO-X
C
COMFORT
iAUTO
COMFORT RADIANT COOLING
F E AT U R E S C O M PA R I S O N & E X P L A N AT I O N
MANUAL HORIZONTAL AIRFLOW DIRECTION CONTROL
Lets you come home to fast cooling. Then enjoy continuous comfort with RADIANT COOLING which avoids direct cooling.
CLEANER AIR
SLEEP Inverter Control
nanoe-G
DUST SENSOR
nanoe-G works effectively on airborne particles including PM2.5, adhesive and in-filter micro-organisms such as bacteria, viruses and mould ensuring a cleaner living environment.
iAUTO Quiet Mode Soft Dry Operation Mode
Monitors particle concentration levels and turns on nanoe-G if levels are high.
REMOVABLE, WASHABLE PANEL
ODOUR-REMOVING FUNCTION
With this function, there's no unpleasant odor when the unit starts up. That's because the fan remains off momentarily, while the source of the odour inside the air conditioner is suppressed.
Personal Airflow Creation Airflow Direction Control (Up & Down)
CLEANER AIR
24-HOUR DUAL ON & OFF REAL SETTING TIMER
nanoe- G
24-HOUR ON & OFF REAL SETTING TIMER
This feature enables you to preset two different sets of start/stop operation timer (hour and minute) within a 24-hour time frame.
Dust Sensor Anti-Bacterial Filter
(Optional)
The exact operating time (hour and minute) of the air conditioner can be set in advance. From here on, the unit will operate in accordance to these preset hours every day until the system is reset.
LONG PIPING
RANDOM AUTO RESTART
Anti-Dust Coating
24-Hour Dual ON & OFF Real Setting Timer
TOP-PANEL MAINTENANCE ACCESS
24-Hour ON & OFF Real Setting Timer
SELF-DIAGNOSTIC FUNCTION Should a malfunction occur, the unit diagnoses the problem and shows the corresponding alphanumeric code. This allows for quicker servicing.
LCD Wireless Remote Control
(Optional)
(Optional)
OPTIONAL ACCESSORIES
(Optional)
RELIABILITY
REMOTE CONTROL
Random Auto Restart (32 Restart Patterns)
Wired Remote Control
FILTER Anti-Bacterial Filter
Blue Fin Condenser
Self-Diagnostic Function
WIRED REMOTE CONTROL
BLUE FIN CONDENSER
(Random)
CONVENIENCE
Top-Panel Maintenance Access
LCD WIRELESS REMOTE CONTROL
RELIABILITY
Removable, Washable Panel
Long Piping (Numbers indicate the maximum pipe length)
Anti-dust coating prevents dust from accumulating on cross flow fan by keeping it clean.
(Optional)
Odour-Removing Function
(Random)
ANTI-DUST COATING
CONVENIENCE
iCOMFORT
Wired Remote Control
The Anti-Bacterial Filter combines three effects in one: anti-allergen, anti-virus and anti-bacterial protection to provide clean air.
The unit must be in cool or dry mode and the fan speed must be set to automatic.
Manual Horizontal Airflow Direction Control
DUST SENSOR
ANTI-BACTERIAL FILTER DUST SENSOR
15m (VS10/VS13) 30m (VS18)
15m
20m (S18/S24) 30m (S28)
10m (C9) 15m (C12)
25m (C18/C24) 30m (C28)
10m (PC9) 15m (PC12)
25m (PC18/PC24) 30m (PC28)
CZ-RD514C CS-VS10SKH, CS-VS13SKH, CS-VS18SKH, CS-S10RKH, CS-S13RKH, CS-S18RKH, CS-S24RKH, CS-S28RKH
CZ-SA22P CS-PC9QKH, CS-PC12QKH, CS-PC18QKH, CS-PC24QKH, CS-PC28QKH
48 - 49
MODEL LINE-UP Capacity (Btu/h)
9,000 / 10,000
12,000 / 13,000
18,000
24,000
INVERTER DELUXE
28,000 FEATURES
INVERTER DELUXE
Wall-Mounted
ELITE INVERTER Page 38-39
CS-VS10SKH
CS-VS13SKH
CS-VS18SKH
(CU-VS10SKH)
(CU-VS13SKH)
(CU-VS18SKH)
(CS-VS10SKH)
DELUXE
DELUXE WIDE
FEATURES
Wall-Mounted
PREMIUM INVERTER Page 40-41
CS-S10RKH
CS-S13RKH
CS-S18RKH
CS-S24RKH
CS-S28RKH
(CU-S10RKH)
(CU-S13RKH)
(CU-S18RKH)
(CU-S24RKH)
(CU-S28RKH)
STANDARD
STANDARD WIDE
FEATURES
Wall-Mounted
DELUXE Page 42-43
CS-C9RKH
CS-C12RKH
CS-C18RKH
CS-C24RKH
CS-C28RKH
(CU-C9RKH)
(CU-C12RKH)
(CU-C18RKH)
(CU-C24RKH)
(CU-C28RKH)
STANDARD
STANDARD WIDE
FEATURES
Wall-Mounted
STANDARD Page 44-45
( ): Outdoor Unit
CS-PC9QKH
CS-PC12QKH
CS-PC18QKH
CS-PC24QKH
CS-PC28QKH
(CU-PC9QKH)
(CU-PC12QKH)
(CU-PC18QKH)
(CU-PC24QKH)
(CU-PC28QKH)
Cooling Models
P R O D U CT L I N E - U P
50 - 51
MEMO
MEMO